Loading...
HomeMy WebLinkAbout18-19978 CITY OF ZEPHYRHILLS 5335-8TH STREET : (813)780-0020 19978 BUILDING PERMIT SINGLE-FAMILY RESIDENTIAL PERMIT-INFORMATION - = .'LOCATION INFORMATION Permit#:19978 Issued: 7/27/2018 Address: 3148 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 10-1-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total Fees: 17,872.97 Subdivision: HIDDEN RIVER Amount Paid: 17,872.97 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-0790. CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-363-2891 Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT APPLICATION FEES BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00 MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 } 1)5 Inspections,Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � � I d i &-- 6m�* S SIGNATURE PERMIT OFFIJFA PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received MA a 3 2018 Phone Contact for Permitting L 813 363 2891 -- L - - - - . . . . T Lennar Homes,LLC 813.574.5700 Owner's Name Owher Phone Number 4600 W.Cypress St.Ste,200,Tampa,FL 33607 Owner's Address Owner Phone Number Fee Simple Titleholder Name I N/A Owner-Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 13148 Kresterbrooke Lane LOT# 0790 SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-0790 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR F7 ADDIALT SIGN DEMOLISH PINSTALL F-] REPAIR PROPOSED USE SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK [Single Family Residence l Pool/Scr'een Enclosure Fence BUILDING SIZE F_U/11 SF 2376 _7 SQ FOOTAGE1936 HEIGHT 1 Story -0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDING I' VALUATION OF TOTAL CONSTRUCTION, ELECTRICAL 1$ F'X_1 AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING 1$ OMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION /7 =GAS W1 ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES DO - - - - - - - - - - - - - - - BUILDER COMPANY Lennar Homes,LLC SIGNATURE ZZ REGISTERED Y/ N FEE CURREN Address 4600 W.Cypr t.Ste.200,Tampa,FL 33607 License# F5C1518166 ELECTRICIAN COMPANY lEdmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Address 11034 Skilfge'r Road,Tampa, FL 33613 License# I EC 13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 530T, Bayonet, FL 34674-5308 License# FCFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 53*, Bayonet, FL 34674-5308 License# FcAC058062 OTHER COMPANY SIGNATURE CZ REGISTERED Y/ N FEE CURREN I x Address 14211 Shoal Li Blvd,Spring Hill, FL 34607 License# PE—P057991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy,Forms;R-O-W Permit for new construction Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Directions-- Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING . (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW - j 'FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3148 Kresterbrooke Lane Permit office: City of ZephyrhiIls City,State,Zip: FL, Permit Number: l��-7 C6 Owner: Lennar Homes Jurisdiction: 6116 - Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1936.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.46 PASS Total Baseline Loads: 62.81 I hereby certify that the plans and specifications covered by Review of the plans and �CHE`ST, r. this calculation are in compliance with the Florida Energy specifications covered by thisp Code. calculation indicates compliance �GII/2 Gal{�1GG� with the Florida Energy Code. 'F+: rrrri %% '�,•';.��=^ titi O 'PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. MAY 0 3 2018 OWNER/AGENT: /ZBUILDING FILIAL: DATE: 4f DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/1/2018 12:22 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3148 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor. Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.46 PASS Total Baseline Loads: 62.81 I hereby certify that the plans and specifications covered by Review of the plans and TkIE SSA this calculation are in compliance with the Florida Energy specifications covered by this ''Q r = p Code. calculation indicates compliance �aveG/, with the Florida Energy Code. PREPARED BY: YC Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. .� with the Florida Energy Code. OWNER/AGENT: mAy n i gnin BUILDING OFFICI �: DATE: DATE: ' - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory�sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/1/2018 12:22 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3148 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1936.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.46 PASS Total Baseline Loads: 62.81 I hereby certify that the plans and specifications covered by Review of the plans andT sT this calculation are in compliance with the Florida Energy specifications covered b this Q - P � 9Y P Y Code. calculation indicates compliance Dave G�I�GGt with the Florida Energy Code. a;,. . PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * �, I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. MAY 0 3 2018 �Oniy OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 PROJECT Title: 1941 B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 Lot# Owner Name: Lennar Homes Total Stories: 1 zBlock/SubdNision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 master 210 1680 No 2 1 1 Yes Yes Yes 2 family rm 341 3171.3 No 0 1 Yes Yes Yes 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ftZ 0 0 1 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ftz e� 0 0 1 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ftZ ___ 0 0 1 4Slab-On-Grade Edge Insulatio kit' 13.5 ft 0 182.3 ft2 1 0 0 5/1/2018 12:22 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 i FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 -� 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 ___ 1 0 0 11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 -_ 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm .30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood 5/1/2018 12:22 PM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 1 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 _11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.25 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0 17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 0 0.25 0.01 0 19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0 _20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>SW 1 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 2 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in None None 4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 5 E=>SE 8 Metal Law-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 6 N=>NE 10 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 5/1/2018 12:22 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft2 416ft2 43.7ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000349 1772.4 97.3 182.99 .2618 6.5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan [[ I�Feb Mar A r Ma Jun X Jul [X]Aue [ ]Oct Nov Dec Heating H Jan [X]Feb f X�Mar f APr I i May rj Jun r l Jul [ ]Aug SeP [ ]Oct Nov Dec Ventin Jan [[ ]]Feb [X Mar [X A r May Jun Jul [ ]Aug Se [X]Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(V11D) \ PM 68 68 M 66 66 68 68 68 68 6 66 66 68 68 68 68 68 8 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1. 5/1/2018 12:22 PM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. „ FL, 1. New construction or existing New(From Plans) 9: Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area(ft2) 1936 b.N/A R= ft2 7. Windows ' Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.54 101.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 b. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 23.00 ft2 a.Central Unit 34.8 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.6 HSPF:8.50 Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building H�Sx . Construction through the above energy saving features which will be installed (or exceeded) �i; in this home before final inspection. Otherwise, a new EPL Display Card will be completed �,o�. based on installed Code compliant features. irtir; =`%,'::,� „ 0 Builder Signature: Date: ` - ~ Address of New Home: 3148 Kres erbrooke Lane City/FL Zip:ZeFhyrhills,FL 33540 *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 12:24 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 1 Building Anal Job: 1941B1 sf ADS Canner g YSIS Date: 5/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.6 7036 25.5 Uds Glazing 30.2 4709 17.0 Wa10ther Doors 23.5 466 1.7 nfiltration Ceilings 1.3 2429 8.8 Floors 3.5 6726 24.3 Infiltration 2.1 3056 11.1 Ducts 3221 11.7 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 .. Ceilings Adjustments 0 Total 27641 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 3500 13.0 Walls Glazing 56.7 8852 33.0 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.5 Floors 0 0 0 Infiltration 0.5 684 2.5 Ducts 3628 13.5 Ventilation 0 0 Glazing Ducts Internal gains 6470 24.1 Blower 0 0 Adjustments 0 Infiltration Total 26857 100.0 Other Ceilings Latent Cooling Load= 3880 Btuh Overall U-value= 0.103 Btuh/ft2-°F Data entries checked. 1 -Fk wrightsc ft- 2018-May-01 12:33:53 MCA Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipment\1941 sf ADS template 3ton Carrier.rup Cale=MJ8 Front Door faces:NW l Pro ect Summar�� Job: 1941B1 sf ADS Carrier J '7 Date: 5/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Notes: FBC 2017 Design In • • Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24421 Btuh Structure 23229 Btuh Ducts 3221 Btuh Ducts 3628 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27641 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26857 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3219 Btuh Ducts 660 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2 1936 1936 Equipment latent load 3880 Btuh Volume(ft') 16360 16360 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30737 Btuh Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC536AO0300 Cond 25HBC536AO0300 AHRI ref 9155179 Coil FX4DNF037L AHRI ref 9155179 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 26 OF Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point= 26 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -� wrightsoft® 2018-May-0112:33:53 •�^^ -• ^p^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..equipment\1941 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:NW Manual S Compliance Report Job: 1941B1 sf ADS Carrier Date: 5/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26857 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 3880 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30737 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29580 Btuh 110% of load Latent capacity: 5220 Btuh 135% of load Total capacity: 34800 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 27641 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26331 Btuh 95% of load Capacity balance: 26 OF Supplemental heat required: 1310 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. wrightsoft® 2018-May-01 12:33:53 Right-Suite®Universal 2018 18.0.16 RSU05714 �CI� Page 1 ...equipment\1941 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces:NW _..� 26 EL lzr �' _�' Ali' °�' _ �—���-— ---._,�� � •� ....�.,....__ .. lot 126 88 Isla t A° I � � 0 F EL 27 EL/ uj 86 EE II ' . 74. 123 I ' 141 ' . .oa,+ 84 --------- 1 WFFEL 31 ' A . __..d...,,.K__J0 144V --.LA 31 145 FFS- A 147 DATE 06/ HIDDEN RIVER SUBDIVISION . 20/06 PROJECT NO. MILS FLORIDA € 49757000 f V SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 L. PLOT PLAN LOT 7 BEARING BASIS: 9 HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEINGS 89*40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT =-211!5-5--EL-SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA =-15-5§--SQ. FT. =-!!-----SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR ENTRY UNDERGROUND FOOTER, STEM WALL, AND GARAGE =-A:!!---SQ. FT. COVERED LANAI Q. FT. II SHOWN. PATIO =-2--3---SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE FT. Iii NOTES TAKE PREFERENCE. A/C & CONC PAD FT. PRIVATE SIDEWALK =-2-9--SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS =-16------7 in PAGE INDICTES THAT PT IS N + ----SQ. FT. PRELIMINARY A STAGE AND ISLA I SUBJECT TO 25 SOD FT. CHANGE AND/OR REVISION. OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY =-L7-5�, 9L--SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD =-ZL4�_—SQ. FT. TO PROPERTY LINE. TOTALS PRELIMINARY DRAWING: AREA = L8-Ll--9-6—S 0. FT. THIS PLAN IS FOR PERMITTING PURPOSES DRIVEWAY FT. ONLY, NOT FOR CONSTRUCTION. VERIFY SIDEWALK =-L1_7�_-SO. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SOD FT. LEGEND: NOTES: --= PROPOSED DRAINAGE FLOW LOT GRADING TYPE = A (00.00) PROPOSED GRADE PROPOSED PAD ELEVATION N/A E-00.00 EXISTING GRADE FRONT SETBACK = 20' BtfUNDA Y SIDE SETBACK = 10' 10' DRAINAGE/UTILITY EASEMENT REAR SETBACK = 10' LOT 80 4.1 Ov 6614 0 a q 1 / Vp ° 0S11 PLAT BOUNDARY q- 710 .00, 12 41 bo. �,ij�jz'k 2 282 Q� '0" bo. e 11 LOT 79 6Q, ',7-V C) LOT 324 HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) LOT 78 770 00, PC(P)-) PRM(P) o TRACT "B" HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) WETLAND CONSERVATION AREA DESCRIPTION: PROPOSED: LOT 79, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", LOWEST FLOOR ELEVATIONS: AS RECORDED IN PLAT BOOK ---, PAGES --- THROUGH LIVING AREA: 72.10' OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A ELEVATIONS REFERENCED TO I CURVE I RADIUS AR CHORD I BEARING DELTA NATIONAL GEODETIC VERTICAL 0 E�4'�1228.13' S 48-02-52" W 33 08'11"40 .00' 231.3 DATUM OF 1929. MEAN SEA CC-30 3 510.00, 72.92- 1 72.86- S 27-23-00" W Ovi 1, C40 400.00- 57A9' 1 57.14- N 27-23.00" E 1 0911-32- LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 ILEGEND. (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= ICONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESMIT= EASEMENT, IF/C= FENCE CORNER, FCM= ,FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE. (R) = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 7155.97 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30- NOT VALID WITHOUT THE SIGNATURE AND jDate of Survey: THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM J 0>& BEACH DATE LICENSED SURVEYOR AND MAPPER ORIDA G. LAND SURVEYOR No. 2984 LB#4493 Revisions: Single. Family Dwelling .Plan Review Gom-men 1: Y.F.E. shall be:a:minimum of.8"_above.the road.elevation.and an'engineered.site plan. -2.:--Lots-shall-be graded.to,comply.with R401.3-of the F.B:.C: 3. :Compaction=test required if 24" or more:of fill dirt is.brought in=at any one place: 4:. :Tie in survey required before pouring concrete.: 5. :Driveways:require a R.O.W. use permit:: All 4:sides of.driveway.thru the sidewalk §Ball have. expansion material: . . 6.. -All setbacks shall be met.; .. :. 7.: :All pro perty=markers shall be,uncovered and marked.at time of first.inspectiori: 8: All A.D.A.-requirements shall be met.:- 9.: .No:electric;plumbing,mechanical;,or training shall be covered without an_inspection and approval first. 10.All Garages shall:comply with:section R302.6:of the:F.B.C. (Fire S:eparation). 11. A lrancesahall not:be installed in.a location where sub ect to rriechanical darns a unless Pp.. .. J. g protected by approved,barriers. M303.4 of.'the F.B:C. 12. Water heaters shall comply:with sectionT607.3 "of the F.B.C: II Foundation supports for.AlC.units.shah be raised at least 3 abovefin'ished grade. M1308.1 14. Return air in all,bedrooms..F.B.C. M.1620.4.- : -- 15._Sirioke detectors are.to be installed:in accordance:-withR313:.1_of the F.B.C.. 16::Ail glazing requirements are:to be-in accordance with R308.4 of the.F.B.C. . 17. All means-of egress are to be in:accordance with R3If of the F.B.C.. :: 18. `-`Green gypsum.board shall not be-used:as.a backer.in':showers or tubs.:R702.4.2.F.B.C: 19.-Combination-type AFCI breakers are.required.at all.locations requiring an AFCI,type breaker: .- -20. Carbon monoxide alarms will.be required in new construction that uses fossil-burning heating or appace or-an attached garage.. They shall be installed inaccordance with the F.B.C: 21. All plumbing,mechanical,:and electrical shall:be.sepaxate from unit.to:unit: This includes all . underground plumbing and electric. 22...All 2016:NRC. Codes:will-be enforced. . .23:Tainper-Resistant Receptacles in.accordance with 406.11 of the 2016 N-.E:C .24::Iri accordance:with the Land:.Developmen't:Code; lots.shall be sodded before final of least 10 feet around:the structure. :: : . 25. Blower door test and-blown in insulation card shall be provided before C.D. 26.A copy ofthe Merzy eacls.shall be with Permit at all times._ 2T Copy of final insulation-renort shall be:provided.with:Permit before:final F.F.E.-Finished Floor Elevation F:B.C=,Florida Building Gode 6 Edition .R.O.W-Right of Way A.D:A.-Americans with.Disabilities Act N.E.C.-National Electric-Code(2011.) 24-26-21-0100-00000-0790 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 24-26-21-0100-00000-0790 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $28,040 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3148 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 " lust Value $28,040 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,040 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 79 Taxable Value $28,040 ---------------------- -----------------OR-9750-PG-2604----------------------------------------------------------------------------------------------------------------------------------------------------------------- Jur.isdiction City of Zeghyrhills Land Detail (Card: 001 of 001) Line_ Use (DescriptionZoning jUnits ,P_ _ (Type rice _ U Condition alue _ is ��0 0100SFR ! MPUD 000.00 SF $4.50 L 1.00 $27,000_ 2 0100 _! SFR MPUD E 1,156.00 SF i $0.90 1.00 1 $1,040 Additional Land_Information Acres 1 0.16 ETax Areal 30Z T FEMA Code t I Residential Code " MHDRVLPI f Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line _ DescriptionYear Units _ P�Value _ w No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page 'Type IDOR CodeCondition�Amount 06/2018 _ 9750 / 2604 '_ Warranty Deed i 05 Vacant ! Multi-Parcel Saley 09/2011 8606 / 3376 ! Warranty Deed _ 05 '~ Vacant Multi-Parcel Sale - - u —� J _ 06j20-10 836.0._j..1872------------1 Certificate of Title----l-----------_2----------------1 Va a - cnt $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000000790 7/18/2018 Lennar Homes-3148 Kresterbrooke Lane 2,376 sq ft Column- SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - i VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,487.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,150.00 Public Fee 1% TOTAL $ 2,150.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,277.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,877.97 ----------------- -- . i PASCO COUNTY, FLORIDA Permit No. /� Date Permitted 7-1s Builder Name/Owner Name 4eArya c C Control#' County Parcel No. Z 2(A-2/-0 06-OW00-07 q0 SubDIv: dde4, t = Address/Location 3 Kees �r ke t!." Classification/Type of Use cylA4 TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: ?, 37 b Exempt ❑Yes 0 No How Determined Impact Fee Amount $. , 02, Zone No. TAZ: SCHOOL IMPACT FEE pp Account (056) Single-Family Detached House Amount $ 7, 1( l 21 (067) Mobile Home (058) Other Residential 123) Collection Fee Exempt � Yes ❑ No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total e , Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined is LIBRARY FEE #: Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amoun RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,plac the building permit owner-on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes-3148 Kresterbrooke Lane-2,376 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 I ADDRESS $ 30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 ' MECHANICAL: $ 144.90 SUB-TOTAL $ 2,145.00 TOTAL $ 2,145.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,272.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,872.97 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday, August 8, 2018 2:29 PM To: Jacqueline Boges Subject: [Request received] 3148 kresterbrooke lane by#19978 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/232319 ...................................................................................................................................................................................................................................................................................................................................................................................... f Jacqueline Boges Aug 8, 1 1 :28 AM MST full service 3148 kresterbooke lane by#19978 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 2018127550 A.pt:1977r,,rol Rec: *10-00 DS: 0.00 IT: 0.00 07/30/2018 C. F. , Dpty Clerk AULA S.0',11E1L,Ph,D.PA5C0 CLERK 8, coMPTROLLER 07 , /30)R SK, og-.02' I of I 7 9 0 r4 PG Permit No. Parcel ID No 24-26-21-0100-00000-0790 NOTICE OF COMMENCEMENT State of. Florida County of Pasco THE,UNDERSIGNED hereby gives notice that improvement Wit be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Commencement: I Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 79 Street Address: 3148 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family Residence Pool Screen Enclosure Fence 3. Owner-information: Lennar Homes, LLC. Name 4600 W Cypress St.Ste 200 Tampa FL. 33607 Address city State Interest in Property: Name of Fee Simple Titleholder: N/A (if other than'owner) Address city State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 - Tampa FL,33607 Address city State Contractor's Telephone No.. 813-574-5700 5. Surety., NIA Name Address city State Amount of Bond: Telephone No.: 6. Lender: -N/A Name Address .. city State Lender's-Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name .4600 W Cypress St,Ste 200 Tampa :FL, 33607. Address city State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of toreceive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity.Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN'YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER ORAN-ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owners Authorized'Officer/Director/Par.tner/Manager Vice President Signatory's Tltle/Office The foregoing instrument was acknowledged beforeme this 30 day of March arch _,by Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes, LLC (name of party on beh 0 6ent was executed). Personally Known A OR Produced Identification❑ Notary Sign_ _!!C < t ISS Type of Identification Produced Name(Print). in). lissa HoliCran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ELISSAMMOLLERAN Signature of Natural Person Signing Above C4111MIU100FF98511131 wpdata/bcs/bcs form, D"dW-7hrjTmy.FiitnlrAUr#flO$$004*7019 nit 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3148 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-0790 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19978 Da s,, 10/31/2018 ISSUE15,BY: ff—UILDINV OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE