HomeMy WebLinkAbout18-19981 CITY OF ZEPHYRHILLS
5335-8TH STREET
' (813)780-0020 19981
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:19981 Issued: 7/27/2018 Address: 3163 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 343,131.90 Total Fees: 18,442.97 Subdivision: HIDDEN RIVER
Amount Paid: 18,442.97 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-1190
CONTRACTOR INFORMATION I OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-363-2891
Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT
APPLICATION FEES
BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00
MECHANICAL FEE 184.80 WATER CONNECTION RESIDEW 1,010.00 SEWER CONNECTION RESIDEW 2,090.00
WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
1
r,
-
�
-�
ZTTI_Swjak
Ins ection e r d
FOOTER 2ND ROUGH PLUMB J/E
INSULATION CEILING
FOOTER BOND DUCTS INSULATED R MISC.
ROUGH ELECTRIC LINTEL SC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
auh 0 A/ &--,
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
� Y Lbw llirz g . .
din 1e. Famil .
Mari Review Comments
- . . I.. .F.F.E,shall be a minimum of$ ? above the.Toad*elevation.and_an.eh6neeredsite plan:
2: Lots,shall.be graded to comply.with:R401:3 .of the F;B.-C:
3. Compaction test required if 24"or more of fill dirt is brought in at.any one:place: -
4: Tie in survey required before,pouring concrete.`
5..:Driveways require:a R.O W:use perinit::AlIA:sides of driveway thru the sidewalk-shall have ;
expansion material. .:
6. All setbacks shall be met':
' 7.. .All ro ert inarkers shallbe.uncovered and marked at time:of first ins ection:.
p. p. .Y. inspection.
8: All-A.:D.A:requirements-shall be:"'et.
9: : No.electric;,plumbing; mechanical;.or framing a -all be covered"withouf.an inspection and
.: .approval first.
.
- 10.- All-Garages:shall comply with section.R302.6 of the.F.B.C:-(Fire Separation):.:
Appliances shall riot b.e installed-in-a location where:subject to mechanical dainage:unless :
pyrotected b a pp roved barriers. M303.4 of the F.B.0
:
12::Water heaters shall-comply with_section P607.3.of the_F.B.C.
I3:.:Fouriilatibn supports..for A/ units shall:be raised.at least.3" above finished grade: IWI l30$:1
14. Return air.in all.bedrooms.-F.B.C. ML620..4
15:.Smoke detectors are to be-installed in-accordance with R313.1 ofthe F.B:C,..
16.All glazing requirements.are to be in,accordance.with R3.08.4.-of the F.B.C.
17.;All.rrieans of egress are..tb be in accordance with R31 l:of the:F.B.C. .:
18. ``Green »
gypsum board sliall.not be'used as a backer'in showers or ttibs.:R702:4.2.F.B.C. : ::
19. Combination-type AFCI breakers.Are'required at all locations requiring an AFCI'type breaker.
20: Carbon monoxide alarnis:will be required in-zxew coistruetion that uses fossil=burning jieatng:-:
-.
or appliances or an:attached garage. They shall:h&installed in:accordance with the F:B:C.
2 L A11_plumbing;mechanical and electrical shall be-separate from unit to unit. This includes all
underground plumbing.and electric: . --
: : 22.- All 2011.N.E:C. Codes will bee'
nforced:
23.Tam_per Resistant Receptacles in accordance with 406.11 of the 20a.1 N.E.
..
24:.In accordance with the Land Developmerit Code,-lots-shall be.sodded before final.'at.Ieast:10
feet around the:structure..
25. Blower.door.test.8hall:be provided before C.CO:
2.6.:. -copy�f the crier cads es be 4vitii peeatit kt all tirites
27'Copy bf Linal insidation report �laall be tea'®viiled with.�errorit before final
_
F.F.E.-Finished Floof Elevation
F.B.C-.Florida Buildirig.Code6�'Edition
K O.W:-Right-of Way
XD:A-Americans with Disabilities Act N.E.C.-National Electric ode
on - :::
Building and Cmisirust ion Sort ices OILS)
PASC ,
COUN�IY FLC)IZII�A�� Blower Door Test Report Form
Property Addre : �p, ./Q
PermR w `JO,KU I Ttles'jft Cmnpa y Name:SKYETEC
Test Dare: !` e,. 01 Tesicr rtart+cHASSEN KHELIFI
TesterGri ti:MY3YG6 cm,tan Phm,e:904-903-1076
1 ,..,,Iiklielifi@skyetec.com
402A.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2
The building or dwelling unit shall be tested and verified as Lasing an air leakage rate of not exceeding 5 air changes
per hour. Testing shall be conducted with a blower door at a prssswr of 0.2 inches w.g.(50 Pascals).As required by
the Building Official,testing stall be conducted by an approved third party.A written repot of the results of the test
shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official Prior to
Certificate of Occupancy issuance.Testing shall be performed at any time after creation ofail scheduled penetrations of
the building thermal envelope.
During testing:(check to verify cone itfon met)
JD Exterior windows and doors,fireplace and stave doors shall be closed,but not sealed,beyond the intended weather-
stripping or other
ampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not seated beyond
'vvv/ nded infiltration
error doors,if installed at the time of the test,shall be open
error doors for continuous ventilation systems and heat recovery ventilators shay be dosed and sealed
abng and cooling systems,if installed at the time of the test,shall be turned off
Supply and return registers,if installed at the time of the test,shall be fully open
Vb Building volurne(flr) _ 97,
Q50 Airflow at 50 Pascal(CFM)
ACHso• Air changes per hour at 50 Pascal
Q5o x 60-Vb= ACHso(3.0 ACH minimum)
Pass Fair❑
E3 Outside Air mechanically introduced to space(less than 3.0 ACH) i
1 hereby certify that the above envelope leakage performance results demonstrate compliance
with Florida Energy Code requirements in accordance with Section R402.4.1.2. i
Signature of Tester I, 9 D' j
Date I
• � I
Jet Streams Ultra Blowing Wool Insulation kNAH[
Attie and Cavity Wail Card ih hwe,h f4ye, e ter1�t,'
Batts and Blankets Equipment Required
h^rr,s a'e�v^.��cnlrrtce arch the mrn!'raC:Jrer s it is recar na.ded t*at a pnearr.ahc bkfmo mettle and a corr4afed base wt1h a nvunkan;.vrte-*=ugabort,a mxrmwm 6V1h
rerr,Trrc--Iat'rs Kf;3;d Irsula'�M ba' !'s an d blank--^'s w I cf 150'Cots to Bte hose sha,td not be Ims tw,3"0'm diarietef.r"cceatabe riaiwvJ feed rate G 5.35 Ibshn Mute.Recot:mer`dad teed
L'lrtie L^^fui'J R"r:;$. r�r.?is 155-25 t 7-"..it$.
R-Value' i Minimum Thickness Thermal Performance(Sidewall and Attic Application)
To obtain ao i s stx:e 1 to al re space(R•vakFFr)is Ixe��ed trl mstaRmg L1 acoasdartCe ww"I the nuxutactustx s aishuc5ors.Faiure ststaa tx
IMsalation resistance Installed iLnutaCo,a should re-1-z d nurnber cf bags Wet;,0W sgla•a fee;and exmeFrl tee maxintlT:i sq za"o(cavera9e per bag as moxivre!ded by the ieA6
(R-Value)of: not be foss than nJ reS d1!o ns aged R values Held b!end'rj d ttiA produ3t wifi otter i.>os--H hsUlal s*nd recommerldw by the mmufaK vwr
R-49 13.75' Cavity Wall Bag Het Weight-nominal 32 tbs.,Minimum 31 lbs.
R•33HD 10.25'
R•38 12.00' R•Valuee Bags per 1000 SF Maximum Not Minimum
To obain as The sentbtr of bees Coverage per Bag Weight per SF
R-30ND $.25' imulte ies par t,fe9 steals feet Caebaets of tua Tho weight per stare
R-30 10-00, Cavity reaistwo of set aree sbowd eel bay stavit not feet of insiaft c!iseetatiow
R-26 900, Framing Depth of. Density be loll flaw: cam More than: sbooid eel be teas Won:
R-22 650, Yx 4' 3 50' R-15 18 SOS ICU.2 ! 16.4 bees 61.0 sq.It 0.525 tbs.
R-21HD 5 50' 2'r.6' 5 50' r R-23 E13Ibsycu.tt 25 8 bags 38.8 sq.It 0.825lbs.
R-19 6.25-R-15HD 3 50' R-31 Icslcu F 34.0 bags 29.4 sq.(t 1.088 Ors,
R•13 3.50' i'x 10' f 9.25' R-39 ( 18 tt3:cue R 43 bags 23.1 sq.tt 1.388 lbs.
R-11 3.50' -P re,--:reti=":a u;•tx f,;. R--'xi.:-9 9-m-de m'"r•3 Demor TO get she Weed R-abao a nsa erdot Ila;'n nsaaw be mUled o:oPa15
_ R-8 250,
Open Attie Application Sag Net Weight-Nominal 32 lbs.,Minimum 31 lbs.
Minimum
88gst Maximiam Minimum Initial Settled
Framing Adjustment 1,000 SF �( Coverage I Weight Installed Thickness`=
To cowWsetr.for Barr.ng rnemtierr,the numr r or t:rp pet Ths m mbar of bays! { roolenta of Will The waigkufF Thickness cowents of this
I fi00 so ft,of area fee b2 truulalud shout ba a3 sl,,-wn berg>', R-Value' t.000 SF of net was {ii bag Amid net or inetMed I81fail d tnsolatioo bag aiwdd
5/M$F 8a siMSF To obtain an initiation thoatd not he fast ? covta trivia""ilaold eat sholaw not be tars seat tdvor Mort
Ba
9 g resrtiante iR-Valuel at, Mae: ! more base, l be lass" M tbaw: that.,
Joist 16"O.C. 24'0.C. R-60 297 33 6 SF 952 Ibs 19.750' 19.750'
R-Value Dimensions Framing Framing
� 29 2 29.4 R-49 23.5 � 42 5 SF ,753 tbs 16 375` 16.375'
2x4
R-60 _2x6 28.9 j 291 R-`4 20.9 47,8 SF 670 tbs i 14.875' 14.875"
2x8 28 6 28 9 R 38 17.8 56.2 Sr= i 569 ibs S3 000' 13.000'
20 23.0 1 23 2 R-30 136 73,3 SF ( 437 tbs 10,375' 10.375'
R-4St 2xu 22 7 22.9 R-26 11.8 i 85 0 SF 377 8,s 9.125' 9.125,
R-22 98 i 102.2 5F 313 lbs. 7,750' 7.750`
2x 20.4 206
R-44 _2x6 20.1 20.3 R-19 8 4 119 3 SF 268 Ibs 6,750' 6,750'
2x8 19.8 20.1 R-13 5.7 175.3 5F 183 tbs 4.750' 4.750'
2x4 17 3 17 4 R 11 A 7 210 8 SF .152 lbs. 4.Q00' 4.000'
R-38 2x6 170 17-2
2x8 16.7 17.0 >.7�:r. �t>7duK•er.ecas•,-,L:t c� a-ate.pruar*,e'raLeM t w r stet..+x"d rre ae +cwwn�+
,:_,r-_1e:rx,-.aaM,lac-.a,c.wrrr-rxa of As;�a:t+t,x era=uV1:re.,,y,.,L..xrJn•«+-tarn•re a'•err.rr 9sorn+r a,aakarrMalt7wesra
2x4 13.2 13.3 t�ssts.:te arowtrsrncezo..a:•,."x;�z�rwaesrs;a-•avegGx. ateocsenxesmmesutrrnrtr»xmruatdpeomrr,wm4snz++oaNrar
2xo 12.9 13.1 rS3e oe:A W tams?}w:.a 3r.+{e.acx€z,•
R-30 _ =o-+c rill as^jrEar,:.tir7:.:-:••:hsu,3_es,rdns.•,r-•m�+a:;,ra c �'ar.Lc_cce-.er:aics i'.+a.Araeat usrSt*arsair rrg.!�CaTa!KR er c9aiea Aeasat+ra
2x8 12.6 129 ' 'S�-0 •7rna r
11.3
2x4 11.4 U
:•, ,:erg'-a asrz.-r -.t
R-26 2x6 11.0 112 Builder's Insulation Statement
Jet Stream Ultra has been installed on conformance w the included included recommendations to provide a thermal resistance of
2x8 108 S 1.0 ..
2x4 - 9 3 9 5 R-Value Thickness
R-22 2x6 9.1 9,3 Attic Area R- at !aches
2x8 8 8 9.1 Sloped Ceilings R- at Inches
2,4 TS BA Wa'.ls R- at Inches
R-19 2x6 77 7.9 Floors(over an unheated crawl space) R- at Inches
2x8 7A 7.7 Drawl Space Per' star R- at Inches
ff
.3 54
R-13 0 5,2 Date Installed
8 5.0 Blo ns lation has been in in conformance vrith the above r ;( r��tvide an R vakee at:
.3 4.4 R-} using tJ bags of this insulation to cove * Niue feet of area
R-11 .1 4.3 at a minimum thickness of _inches.
.8 4,1 YV
ut rnt.oAmeM !nsuW:4n Gonrrapnr Isgna!a )
r-;rr- �•:u'a-s�.�_�ct::�r Cis%+tsY !L.'+ ..,��a--------.""_'""'--sy� ---t
t -in
Ut 1~L-irrr OVrrtOUAaO HCme SukfM(l,O'-mule)
r..rr:tver7sn Pres,Arc'* ._ `. _._. �.�.� __ �___.____--a._._--•-_ _.__�,_.- ._- ._..�._......��
• . . .a,:a:,e F^pee ,x„r,r
The eoverage Information on this AtlicfSidewatl card applies to the entire United States(including Min nasota).
www.knautinsulation.us Knaui Insulation,Inc. One Knauf Drive,Shetbyvik IN 46176 Tel:(WO)825.4434 ext.8300 FAX_(317)398-3675
2018127555
fgcpt:1977661 Rec: 1"0.00
PS: 0.00 IT: 0.00
07/30/2018 C. F. , Dpty Clerk
PAULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER
.07/30/2018 09:02am I of I
OR BK 9764 Ps
Permit No. Parcel ID No 24-26-21-0100-00000-1190
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real.property,and In accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1-.* Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 119
Street Address: 3163 Kresterbrooke Lane ZephryhIlls FL 33541
2. General Description of Improvement Single Family Residence Pool./Screen Enclosure Fence
3. Owner Information: Lennar Homes,LLC.
Name
4600 W Cypress St. Ste,200 Tampa FL. 33607
Address city State
Interest in Property:
Name of.Fee Simple Titleholder: N/A
'(If other than owner)
Address city State
4. Contractor: Lennar Homes, LLC
Name -
4600 W Cypress St, Ste 200 Tampa FL,33607-
Address city State
Contractor's Telephone No.: 813.574.5700
-6. Surety., NIA -
Name
Address city State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Addresscity State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL 33607,
Address city State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A. of
to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording.unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
MENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO'09TAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The.foregoing.instrument was acknowledged before me this 30 day of March _,by
Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for
Lennar Homes, LLC (name of party a alf of whomi nsirmleent was executed).
Personally Known AOR Produced Identification 0 Notary Sig(a—lure
Type of Identification Produced Name(Print)%-- a- Holleran
Verification Verification pursuant to Section 92.525,Florida Statutes. Under penalties of .perjury,I declare that I have read the foregoing and that the facts stated in
owreffa—I 6
it are true to the best of my knowledge and belief.
ELISSAMMOUMN Signature of Natural Person Signing Above
Offte3rJUne 0.2020
wpdata/bcs/bcs form,, Pnod7bmTroyF&Iolnsuitnotal4wyolg
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfi.zendesk.com>
Sent: Wednesday,August 8, 2018 12:48 PM
To: Jacqueline Boges
Subject: [Request received] 3163 Kresterbrooke Lane bp#1 9981
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/232266
................ ...................................-..................................I.......................................................................................................... ................................................................................... ................
Jacqueline Boges
Aug 8, 9:47 AM MST
full service 3163 kresterbrooke lane bp#1 9981 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
813-780-0020 City of Zephyrhills Permit Application FakS13-780-0021
Building Department
Date Received MAY 0 3 2018 Phone Contact for Permittin 813 363 2891
Owner's Name Lennar Homes,LLC
Owner Phone Number 13-574,5700
Owner's Address 4600 W.Cypress St.Ste..20.0,Tampa,FL 33607 Owner Phone Number—]
Fee Simple Titleholder Name N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 3163 Kresterbrooke Lane LOT# 1190
SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-1190
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN Q Q DEMOLISH
P INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL
DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure Fence
BUILDING S13FE F—u/R SF 3046 SQ FOOTAGE2584 HEIGHT 12 Story
. . . N a`rq - a a & % 2 a - - a - aBUILDING VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL 1$ PROGRESS ENERGY Q W.R.E.C.
AMP SERVICE
VIPLUMBING 1$
MECHANICAL VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES 0
D
BUILDER COMPANY Lermar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 14600 W.Cypress St.Ste.200,Tampa,FL 33607 License# FGC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skipper Road,Tampa, FL 33613 License# I EC130054 08
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREK I Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5308 License#1 CFC042998
MECHANICAL- COMPANY BayonetPlumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 53 yonet, FL 34674-5308 License#- CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N EN FEE CURREN A i —
Address 14211 Shoal Line Nvd, Spring Hill, FL 34607 License# [ECC057991
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;,R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans;Stormwater Plans wl Silt Fence installed,
Sanitary Facilities&I.dbmpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ . . . . . . . . . .
Directions:
Fill.out application completely.
Owner&Contractor sign back of application,notarized
If over$2600,a Notice of Commencement Is required. (AIC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E.
LOT 119 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
LOT FT. EASEMENTS AND RESTRICTIONS OF RECORD.
LIVING AREA =__L09_3___SQ. FT.
ENTRY FT. n
UNDERGROUND FOOTER, STEM WALL, AND
GARAGE =__±ZZ____SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR
COVERED LANAI FT. SHOWN.
PATIO =_!!--SQ. FT.
CONC. DRIVE =—AQL--SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
L;j NOTES TAKE PREFERENCE,
A/C & CONC PAD FT.
PRIVATE SIDEWALK FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS PAGE INDICATES THAT PLAT IS IN
2034 —SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO
SOD FT. CHANGE AND/OR REVISION.
OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
RIGHT OF WAY =__j.9_7Q._89_SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
DRIVE APRON = Lj±_SQ. FT.
PUBLIC SIDEWALK _ FT. STRUCTURE TIES SHOWN HEREON DENOTES
SOD FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
TO PROPERTY LINE.
TOTALS PRELIMINARY DRAWING:
AREA FT. THIS PLAN IS FOR PERMITTING PURPOSES
DRIVEWAY FT. ONLY, NOT FOR CONSTRUCTION. VERIFY
SIDEWALK FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
SOD S Q. FT.
NOTES: A LEGEND:
LOT GRADING TYPE = A
_ --= PROPOSED DRAINAGE FLOW
(00.00) PROPOSED GRADE
PROPOSED PAD ELEVATION N/A E-00.00 = EXISTING GRADE
FRONT SETBACK = 20' 10- DRAINAGE/UTILITY EASEMENT
SIDE SETBACK = 10' LOT 105
REAR SETBACK 10* HIDDEN RIVER PHASE ONE A 's LOT 120
(PLAT BOOK 74, PAGES 101-121) .0 0. PLAT
BOUNDARY
S 78-1 7'12"
10.00,
40
40('V12 25.00,
..........
LOT 119
LOT 106
HIDDEN RIVER PHASE ONE A 0
(PLAT BOOK 74, PAGES 101-121) x 0 Al
0 to
p A /44J
z............
Q N.
A
4,j
A
PLAT 9
BOUNDARY •
19,
137 iz,
LOT 118 770
00,
C,
DESCRIPTION: A PROPOSED:
LOT 119, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B" LOWEST FLOOR ELEVATIONS:
AS RECORDED IN PLAT BOOK __ PAGES --- THROUGH LIVING AREA: 72.35'
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A
PC(P) ELEVATIONS REFERENCED TO
NATIONAL GEODETIC VERTICAL
I CURVE RAP C CHORD BEARING DELTA PRM(P)
CO go!g§00, 2, 230.44- S 45*23'43" W 38*26'28"
230.4 .
3 DATUM OF 1929. MEAN SEA,
87.50 LEVEL= 00.00 FT.
I C52 1 240.00- 1 60.16' 60.00
APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992
LEGEND:
(C) ALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, rk= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
= C
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, MR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: Sms Square Feet: 8133.71 t LE'NNAR HOMES
SURVEYORS AND MAPPERS Checked By:
911 WEST ST. PETERSBURG DRIVE
ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30-
NOT VALID WITHOUT THE SIGNATURE AND jDate of Survey:
THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04./19/2018 RTM R, BEACH DATE
LICENSED SURVEYOR AND MAPPER FLORI REG. LAND SURVEYOR No. 2984 LB#4493
Revisions:
r MET I
EL..
127 A
0 4M
6 98
A
L
LU 1 4
FF EL
EL FFFr;L7
All
A 126 IZ'A' ter
zA I 34TFEL102 73=A1.42 IL ------ At A IH-3OL ----------I07 AV YE]
SCALEley-Hom AEZ NOT EDasa'-HORN AND ASSOCIATES, INC. DRAWN BY1-0400 FAX (1114) -78Z-497E CHECHED BY
ff
'Ph
EL
7 19 Al 7 EL
w
I
7MM7
�A I
FFa
IJA 7A
r 7. -1 FF EL
VIR7
=A
'F 72
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE,FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3163 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number: (L
Owner: Lennar Homes Jurisdiction: 611600 `
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:.2nd Floor 6 218.6
a. U-Factor: Dbl, U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.56 a.Central Unit 18.0 SEER:15.00
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.068
Total Proposed Modified Loads: 74.84 PASS
Total Baseline Loads: 74.78
hereby certify that the plans and specifications covered by Review of the plans andT ;ST,q�,.
this calculation are in compliance with the Florida Energy specifications covered by this 'a
Code. calculation indicates compliance
q /., with the Florida Energy Code.
PREPARED BY: ��VG Aujl h Before construction is completed
DATE: this building will be inspected for a
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.with the Florida Energy Code.' Op'y1Z
MAY 0 3 201� -
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE: 7�
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3163 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sgft.) Insulation Area
a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b€N/A R= ftZ
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31 \J
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2582.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.068
Total Proposed Modified Loads: 74.84 PASS
Total Baseline Loads: 74.78
I hereby certify that the plans and specifications covered by Review of the plans and, $T'
this calculation are in compliance with the Florida Energy i specifications covered by this
Code. calculation indicates compliance !;,,'''
,I with the Florida Energy Code.
PREPARED BY: Z)ave G f�tCh Before construction is completed
C' E7
DATE: this building will be inspected for � __..l;};�4_
compliance with Section 553.908
I hereby certify that this building,a designed, is in compliance Florida Statutes. .r,
with the Florida Energy Code. MAY O 3 2019
OWNER/AGENT: BUILDING OFFICIA
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3163 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: _. Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types•(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz
4. Number of Bedrooms 4 d.N/A R= ftZ
10.Ceiling Types (1489.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ftz
6. Conditioned floor area above grade(ftz) 2582 b.N/A R= ftZ
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ftz b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (2582.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ftz None
c.other(see details) R= 433.00 ftz 15.Credits Pstat
Glass/Floor Area: 0.068
Total Proposed Modified Loads: 74.84 PASS
Total Baseline Loads: 74.78
I hereby certify that the plans and specifications covered by Review of the plans and -TkS�' T
this calculation are in compliance with the Florida Energy specifications covered by this4 �. p
Code. calculation indicates compliance
/✓
with the Florida Energy Code. F+' �rrri;�'%; ,, ; ,,,•+`� n
PREPARED BY: Dave A-ad h Before construction is completed
DATE: this buildingwill be inspected for
P
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. OLj F
MAY 0 3 2098 - -
OWNER/AGENT: BUILDING OFFICIAL: ,
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory�sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: 2575B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2582 Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 90 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1093 9399.8
2 Block2 1489 11912
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes
2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes
FLOORS :
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 -_ 0.3 0 0.7
2 Raised Floor 2nd Floor --_ --e 13 ft2 11 0 0 1
i
3 Floor over Garage 2nd Floor 420 ft2 11 0.2 0 0.8
4 Floor Over Other Space 2nd Flood ____ ___ 1056 ft2 0 0.2 0 0.8 j
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch 1
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1489 ft2 N N
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>E Exterior Concrete Block-Int Insul list Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0
2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0
3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0
4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0
5 N=>E Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0
_ 6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0
7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0
9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0
11 S=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>E Wood 1 st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening',
3 S=>W 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None
4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None
6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>E 7 Metal ; Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
9 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
10 N=>E 1 Metal Low-E Double .Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None ;I
GARAGE
i
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 420 ft2 420 ft2 41 ft 8.6 ft 1
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 '
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 256.71 .339 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts'
1 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 54.7 cfm 0.05 0.60 1 1
2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 74.5 cfm 0.05 0.60 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling I [[ ]]Jan [[ I]Feb [[ ]]Mar [ ]Apr [[ ]May [X]Jun ri
Jul [X]Aug n
Sep [ ]Oct [ ]Nov [ ]Dec
Heating [X]Jan [X]Feb [X]Mar [ ]Apr [ ]May [ ]Jun Jul [ ]Aug SeP [ ]Oct [X]Nov [X]Dec
Ventin [ ]Jan [ ]Feb X Mar [X]A r [ ]Ma [ ]Jun Jul [ ]Au Se [X]Oct [X]Nov [ ]Dec
I
I
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
i
f
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
I
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes
10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1489.00 ftZ
6. Conditioned floor area(ftz) 2582 b.N/A R= ftz
7. Windows" Description Area c.N/A R= ftz
a. U-Factor: Dbl,U=0.54 71.25 ftz 11.Ducts R ftz
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
b. U-Factor: Dbl,U=0.56 71.00 ftz
SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl, U=0.56 33.33 ftz a.Central Unit 18.0 SEER:15.00
SHGC: SHGC=0.32 b.Central Unit 24.0 SEER:15.50
d. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
SHGC a.Electric Heat Pump 17.7 HSPF:8.50
Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft EF:0.95
b.Floor Over Other Space R=0.0 1056.00 ftz
c.other(see details) R= 433.00 ftz b. Conservation features
None
15.Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded) .�0 ' S(;4T1?o.' .
in this home before final inspection. Otherwise, a new EPL Display Card will be completed w�",,''f� `��;,•'0;;,•
based on installed Code compliant features. 14
Builder Signature: Date:. 05/02/18
'
Address of New Home: 3163 Kresterbrooke Lane City/FL Zip: ZeFh�rhills,F1 33540
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/1/2018 9:00 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
r '
Buildin Anal $1$ Job: 2575B1 sf ADS Carrier
g y Date: 5/1/2018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project I • •
For: Lennar Homes
Design C• • •
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(OF) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Walls 5.5 5191 31.9 ucts
Glazing 30.2 2683 16.5 nfiltraton
Doors 21.2 432 2.7 wads
Ceilings 1.7 60 0.4
Floors 4.1 4478 27.5
Infiltration 1.9 2039 12.5
Ducts 1400 8.6
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Doors Other
Adjustments 0
Total 16284 100.0
• •
Component Btuh/ft2 Btuh % of load
Walls 2.8 2641 23:2 Internal Gains
Glazing 56.3 5004 44.1 wall
Doors 16.6 338 3.0
Ceilings 2.0 67 0.6 Ducts
Floors 0 0 0
Infiltration 0.4 454 4.0
Ducts 1655 14.6 Infiltration
Ventilation 0 0 Other
Internal gains 1200 10.6 Doors
Blower 0 0
Adjustments 0 Glazing
Total 11360 100.0
Latent Cooling Load= 1237 Btuh
Overall U-value= 0.150 Btuh/ft2-°F
Data entries checked.
- ' igf�tsq . 2018-May-01 09:33:44
^��°t w �� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Cale=MJ8 Front Door faces: E
Buildin Anal SIS Job: 2575B1 sf ADS Carrier
g Y Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Piroject Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 280N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft' Btuh % of load
Walls 3.8 4204 32.8 acts
Glazing 30.2 2608 20.3
Doors 0 0 0 wall
Ceilings 1.3 1868 14.6 nfiltration
Floors 0 0 0
Infiltration 1.9 2299 17.9
Ducts 1846 14.4
Piping 0 0
Humidification 0 0 1 Ceilings
Ventilation 0 0 Glazing
Adjustments 0
Total 12825 100.0
Component Btuh/ftz Btuh % of load
Walls 2.7 :3035 16.8 Wall
Glazing 53.0 4581 25.4
Doors 0 0 0 Internal Gains
Ceilings 1.7 2583 14.3
Floors 0 0 0
Infiltration 0.4 512 2.8 1
Ducts 2137 11.8
Ventilation 0 0 Glazing
Internal gains 5213 28.9
Blower 0 0 Ducts
Adjustments 0 Infiltration
Total 118061 100.0 Ceilings
Latent Cooling Load= 3191 Btuh
Overall U-value= 0.083 Btuh/ft2-°F
Data entries checked.
` -F- wrightsoft- 2018-May-01 09:33:44
ACCA Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E
Project Summary Job: 2575B1 sf ADS Carrier
1 Date: 5/1/2018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Notes:
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14883 Btuh Structure 9705 Btuh
Ducts 1400 Btuh Ducts 1655 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
Humidification 0 Btuh BI (none)
e) 0 Btuh
Piping 0 Btuh
Equipment load 16284 Btuh Use manufacturer's data
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 11360 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 942 Btuh
Ducts 294 Btuh
Central vent(0 cfm) 0 Btuh
Heating Coolingg (none)
Area(ftz) 1093 1093 Equipment latent load 1237 Btuh
Volume(ft') 9654 9654
Air'changes/hour ' 0.29 0.16 Equipment Total Load (Sen+Lat) 12596 Btuh
Equiv.AVF (cfm), 47 25 Req. total capacity at 0.85 SHR 1.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC518AO0300 Cond 25HBC518AO0300
AHRI ref 9154643 Coil FB4CNP025L
AHRI ref 9154643
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 15300: Btuh
Heating output 17700 Btuh @ 47°F Latent cooling 2700; Btuh
Temperature rise 27 OF Total cooling 18000' Btuh
Actual air flow 600 cfm Actual air flow 600 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Capacity balance point= 30 OF
Backup:
Input=4 kW, Output= 15295 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
L -Fk- wrightsof[o 2018-May-01 09:33:44
•-^ �- ^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E
Pro ect Summa Job: 2575B1 sf ADS Carrier
1 ry Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project Inf• •
For: Lennar Homes
Notes:
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10978 Btuh Structure 15924 Btuh
Ducts 1846 Btuh Ducts 2137 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12825 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 18061 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2812 Btuh
Ducts 379 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1489 1489 Equipment latent load 3191 Btuh
Volume(W) 11912 11912
Air changes/hour 0.27 1 0.14 Equipment Total Load (Sen+Lat) 21252 Btuh
Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 3600, Btuh
Temperature rise 27 OF Total cooling 240001 Btuh
Actual air flow 800 cfm Actual air flow 800, cfm
Air flow factor 0.062 cfm/Btuh Air flow factor 0.044 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.85
Capacity balance point= 16 OF
Backup:
Input= 3 kW, Output= 11787 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- wrightsoft®�� •�^-�° °•°°--��.P� Right-Suite®Universal 2018 18.0.18 RSU05714 2018-May-01 09:33:44
Page 2
..ent\25758 sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E
Manual S Com liance Re ort Job: 2575B1 sf ADS Carrier
p p Date: 511/2018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F
Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F
Indoor design DB: 75.0°F Total gain: 12596 Btuh
Indoor RH: 50% Estimated airflow: 600 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Sensible capacity: 15300 Btuh 135% of load
Latent capacity: 2700 Btuh 218% of load
Total capacity: 18000 Btuh 143% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 16284 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
_ f
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Output capacity: 13453 Btuh 83% of load Capacity balance: 30 OF
Supplemental heat required: 2831 Btuh Economic balance: -99 OF
Backupequipment t e: Elec strip
type: p
Manufacturer: Model:
Actual airflow: 600 cfm
Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF
Meets all requirements of ACCA Manual S.
'y Wrightsoft® 2018-May-01 09:33:44
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
AC(:;k ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E
Manual S Compliance Report Job: 2575B1 sf ADS Carrier
Date: 5/112018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project •
For: Lennar Homes
Cooling •
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 18061 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.3°F Latent gain: 3191 Btuh Entering coil WB: 62.87
Indoor design DB: 75.0°F Total gain: 21252 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 113% of load
Latent capacity: 3600 Btuh 113% of load
Total capacity: 24000 Btuh 113% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 24000 Btuh 187% of load Capacity balance: 16 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model
Actual airflow: 800 cfm
Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
L -4-1- Wrightsoft® 2018-May-01 09:33:44
•r• a ow����mp Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Cale=MJ8 Front Door faces: E
Lennar Homes-3163 Kresterbrooke Lane-3,046 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 3,046 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00 j
OTHER: - $ -
VALUATION $ 343,131.90
FEE SHEET $ 1,760.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,870.20
ELECTRICAL: $ 396.00
PLUMBING: $ 264.00
MECHANICAL: $ 184.80
SUB-TOTAL $ 2,715.00
TOTAL $ 2,715.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
I
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,842.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,442.97
Lennar Homes-3163 Kresterbrooke Lane 3,046 sq ft
Column
SQ. FEET PRICE
MAIN OR LIVING: 3,046 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 343,131.90
i
FEE SHEET $ 1,760.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,875.20
ELECTRICAL: $ 396.00
PLUMBING: $ 264.00
MECHANICAL: $ 184.80
SUB-TOTAL $ 2,720.00
Public Fee 1%
TOTAL $ 2,720.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
i
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,847.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,447.97
• i
24-26-21-0100-00000-1190 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, July 14, 2018
Parcel ID 24-26-21-0100-00000-1190 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land ! $0
4600 W CYPRESS ST STE 200 Land $28,921
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3163 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540 Just Value $28,921
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,921
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 119 Taxable Value $28,921
OR 9750 PG 2604
Jurisdiction
City of Zephyrhills
—Li
Land Detail (Card: 001 of 001) .
Line Use Description�ZoningUnits ;p _L_P it ce ,Condition Value
_ 1 -0100 SFR MUD 6,000.00 SF $4.50 ' 1.00 $27,000^
- 2 —�-- 0100 SFR , MPUD 2,134.00 { SF $0.90 1.00 $1,921
Additional Land Information
M
Acres 0.19 Tax Area 30Z FEH Code Residential Code HDRVLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ Extra Features (Card: 001 of 001) _
Line Description_ ear _ knits _V_ Value
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year_ Book/Page ^� Ty ep _ � D_O_R Code Condition !Amount
�06/2018 9750 / 2604� Warranty Deed 05 Vacant Multi-Parcel Sale Y
09/2011 8606 / 3376_ ( Warranty Deed V 05 Vacant Multi-Parcel Sale
06/2010 8360 / 1872 Certificate of Title 12 Vacant —`$0
i
I
i
i
i
. I
http://search.pascopa.com/parcel.aspx?parcel=2126240100000001190 7/18/2018
PASCO COUNTY, FLORIDA
- _ Permit No. _^
Date Permitted 7-I1 Cb
Builder Name/Owner Name 1"A a_t, Control#'
: County Parcel No. �1-'Z '-L(- jL�-p(Y � [�!D SubDiv: 141d6feA
Address/Location
Classificatlonrrype of Use '5 ' o
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
G;.. Exempt ❑Yes ❑ No How Determined
Impact Fee Amount $. 3, {32- . Zone No. TAZ:
U'
t SCHOOL IMPACT FEE -
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt ( Yes ❑No How Determined
PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑Yes ❑ No How Determined. j
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total "
Exempt ❑Yes ❑ No How Determined Total Amount (J
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
t PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY i
?k i
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,piecing
the building permit owner.on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY