Loading...
HomeMy WebLinkAbout18-19981 CITY OF ZEPHYRHILLS 5335-8TH STREET ' (813)780-0020 19981 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19981 Issued: 7/27/2018 Address: 3163 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 18,442.97 Subdivision: HIDDEN RIVER Amount Paid: 18,442.97 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-1190 CONTRACTOR INFORMATION I OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-363-2891 Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 WATER CONNECTION RESIDEW 1,010.00 SEWER CONNECTION RESIDEW 2,090.00 WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 1 r, - � -� ZTTI_Swjak Ins ection e r d FOOTER 2ND ROUGH PLUMB J/E INSULATION CEILING FOOTER BOND DUCTS INSULATED R MISC. ROUGH ELECTRIC LINTEL SC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. auh 0 A/ &--, CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � Y Lbw llirz g . . din 1e. Famil . Mari Review Comments - . . I.. .F.F.E,shall be a minimum of$ ? above the.Toad*elevation.and_an.eh6neeredsite plan: 2: Lots,shall.be graded to comply.with:R401:3 .of the F;B.-C: 3. Compaction test required if 24"or more of fill dirt is brought in at.any one:place: - 4: Tie in survey required before,pouring concrete.` 5..:Driveways require:a R.O W:use perinit::AlIA:sides of driveway thru the sidewalk-shall have ; expansion material. .: 6. All setbacks shall be met': ' 7.. .All ro ert inarkers shallbe.uncovered and marked at time:of first ins ection:. p. p. .Y. inspection. 8: All-A.:D.A:requirements-shall be:"'et. 9: : No.electric;,plumbing; mechanical;.or framing a -all be covered"withouf.an inspection and .: .approval first. . - 10.- All-Garages:shall comply with section.R302.6 of the.F.B.C:-(Fire Separation):.: Appliances shall riot b.e installed-in-a location where:subject to mechanical dainage:unless : pyrotected b a pp roved barriers. M303.4 of the F.B.0 : 12::Water heaters shall-comply with_section P607.3.of the_F.B.C. I3:.:Fouriilatibn supports..for A/ units shall:be raised.at least.3" above finished grade: IWI l30$:1 14. Return air.in all.bedrooms.-F.B.C. ML620..4 15:.Smoke detectors are to be-installed in-accordance with R313.1 ofthe F.B:C,.. 16.All glazing requirements.are to be in,accordance.with R3.08.4.-of the F.B.C. 17.;All.rrieans of egress are..tb be in accordance with R31 l:of the:F.B.C. .: 18. ``Green » gypsum board sliall.not be'used as a backer'in showers or ttibs.:R702:4.2.F.B.C. : :: 19. Combination-type AFCI breakers.Are'required at all locations requiring an AFCI'type breaker. 20: Carbon monoxide alarnis:will be required in-zxew coistruetion that uses fossil=burning jieatng:-: -. or appliances or an:attached garage. They shall:h&installed in:accordance with the F:B:C. 2 L A11_plumbing;mechanical and electrical shall be-separate from unit to unit. This includes all underground plumbing.and electric: . -- : : 22.- All 2011.N.E:C. Codes will bee' nforced: 23.Tam_per Resistant Receptacles in accordance with 406.11 of the 20a.1 N.E. .. 24:.In accordance with the Land Developmerit Code,-lots-shall be.sodded before final.'at.Ieast:10 feet around the:structure.. 25. Blower.door.test.8hall:be provided before C.CO: 2.6.:. -copy�f the crier cads es be 4vitii peeatit kt all tirites 27'Copy bf Linal insidation report �laall be tea'®viiled with.�errorit before final _ F.F.E.-Finished Floof Elevation F.B.C-.Florida Buildirig.Code6�'Edition K O.W:-Right-of Way XD:A-Americans with Disabilities Act N.E.C.-National Electric ode on - ::: Building and Cmisirust ion Sort ices OILS) PASC , COUN�IY FLC)IZII�A�� Blower Door Test Report Form Property Addre : �p, ./Q PermR w `JO,KU I Ttles'jft Cmnpa y Name:SKYETEC Test Dare: !` e,. 01 Tesicr rtart+cHASSEN KHELIFI TesterGri ti:MY3YG6 cm,tan Phm,e:904-903-1076 1 ,..,,Iiklielifi@skyetec.com 402A.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as Lasing an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a prssswr of 0.2 inches w.g.(50 Pascals).As required by the Building Official,testing stall be conducted by an approved third party.A written repot of the results of the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official Prior to Certificate of Occupancy issuance.Testing shall be performed at any time after creation ofail scheduled penetrations of the building thermal envelope. During testing:(check to verify cone itfon met) JD Exterior windows and doors,fireplace and stave doors shall be closed,but not sealed,beyond the intended weather- stripping or other ampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not seated beyond 'vvv/ nded infiltration error doors,if installed at the time of the test,shall be open error doors for continuous ventilation systems and heat recovery ventilators shay be dosed and sealed abng and cooling systems,if installed at the time of the test,shall be turned off Supply and return registers,if installed at the time of the test,shall be fully open Vb Building volurne(flr) _ 97, Q50 Airflow at 50 Pascal(CFM) ACHso• Air changes per hour at 50 Pascal Q5o x 60-Vb= ACHso(3.0 ACH minimum) Pass Fair❑ E3 Outside Air mechanically introduced to space(less than 3.0 ACH) i 1 hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. i Signature of Tester I, 9 D' j Date I • � I Jet Streams Ultra Blowing Wool Insulation kNAH[ Attie and Cavity Wail Card ih hwe,h f4ye, e ter1�t,' Batts and Blankets Equipment Required h^rr,s a'e�v^.��cnlrrtce arch the mrn!'raC:Jrer s it is recar na.ded t*at a pnearr.ahc bkfmo mettle and a corr4afed base wt1h a nvunkan;.vrte-*=ugabort,a mxrmwm 6V1h rerr,Trrc--Iat'rs Kf;3;d Irsula'�M ba' !'s an d blank--^'s w I cf 150'Cots to Bte hose sha,td not be Ims tw,3"0'm diarietef.r"cceatabe riaiwvJ feed rate G 5.35 Ibshn Mute.Recot:mer`dad teed L'lrtie L^^fui'J R"r:;$. r�r.?is 155-25 t 7-"..it$. R-Value' i Minimum Thickness Thermal Performance(Sidewall and Attic Application) To obtain ao i s stx:e 1 to al re space(R•vakFFr)is Ixe��ed trl mstaRmg L1 acoasdartCe ww"I the nuxutactustx s aishuc5ors.Faiure ststaa tx IMsalation resistance Installed iLnutaCo,a should re-1-z d nurnber cf bags Wet;,0W sgla•a fee;and exmeFrl tee maxintlT:i sq za"o(cavera9e per bag as moxivre!ded by the ieA6 (R-Value)of: not be foss than nJ reS d1!o ns aged R values Held b!end'rj d ttiA produ3t wifi otter i.>os--H hsUlal s*nd recommerldw by the mmufaK vwr R-49 13.75' Cavity Wall Bag Het Weight-nominal 32 tbs.,Minimum 31 lbs. R•33HD 10.25' R•38 12.00' R•Valuee Bags per 1000 SF Maximum Not Minimum To obain as The sentbtr of bees Coverage per Bag Weight per SF R-30ND $.25' imulte ies par t,fe9 steals feet Caebaets of tua Tho weight per stare R-30 10-00, Cavity reaistwo of set aree sbowd eel bay stavit not feet of insiaft c!iseetatiow R-26 900, Framing Depth of. Density be loll flaw: cam More than: sbooid eel be teas Won: R-22 650, Yx 4' 3 50' R-15 18 SOS ICU.2 ! 16.4 bees 61.0 sq.It 0.525 tbs. R-21HD 5 50' 2'r.6' 5 50' r R-23 E13Ibsycu.tt 25 8 bags 38.8 sq.It 0.825lbs. R-19 6.25-R-15HD 3 50' R-31 Icslcu F 34.0 bags 29.4 sq.(t 1.088 Ors, R•13 3.50' i'x 10' f 9.25' R-39 ( 18 tt3:cue R 43 bags 23.1 sq.tt 1.388 lbs. R-11 3.50' -P re,--:reti=":a u;•tx f,;. R--'xi.:-9 9-m-de m'"r•3 Demor TO get she Weed R-abao a nsa erdot Ila;'n nsaaw be mUled o:oPa15 _ R-8 250, Open Attie Application Sag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. Minimum 88gst Maximiam Minimum Initial Settled Framing Adjustment 1,000 SF �( Coverage I Weight Installed Thickness`= To cowWsetr.for Barr.ng rnemtierr,the numr r or t:rp pet Ths m mbar of bays! { roolenta of Will The waigkufF Thickness cowents of this I fi00 so ft,of area fee b2 truulalud shout ba a3 sl,,-wn berg>', R-Value' t.000 SF of net was {ii bag Amid net or inetMed I81fail d tnsolatioo bag aiwdd 5/M$F 8a siMSF To obtain an initiation thoatd not he fast ? covta trivia""ilaold eat sholaw not be tars seat tdvor Mort Ba 9 g resrtiante iR-Valuel at, Mae: ! more base, l be lass" M tbaw: that., Joist 16"O.C. 24'0.C. R-60 297 33 6 SF 952 Ibs 19.750' 19.750' R-Value Dimensions Framing Framing � 29 2 29.4 R-49 23.5 � 42 5 SF ,753 tbs 16 375` 16.375' 2x4 R-60 _2x6 28.9 j 291 R-`4 20.9 47,8 SF 670 tbs i 14.875' 14.875" 2x8 28 6 28 9 R 38 17.8 56.2 Sr= i 569 ibs S3 000' 13.000' 20 23.0 1 23 2 R-30 136 73,3 SF ( 437 tbs 10,375' 10.375' R-4St 2xu 22 7 22.9 R-26 11.8 i 85 0 SF 377 8,s 9.125' 9.125, R-22 98 i 102.2 5F 313 lbs. 7,750' 7.750` 2x 20.4 206 R-44 _2x6 20.1 20.3 R-19 8 4 119 3 SF 268 Ibs 6,750' 6,750' 2x8 19.8 20.1 R-13 5.7 175.3 5F 183 tbs 4.750' 4.750' 2x4 17 3 17 4 R 11 A 7 210 8 SF .152 lbs. 4.Q00' 4.000' R-38 2x6 170 17-2 2x8 16.7 17.0 >.7�:r. �t>7duK•er.ecas•,-,L:t c� a-ate.pruar*,e'raLeM t w r stet..+x"d rre ae +cwwn�+ ,:_,r-_1e:rx,-.aaM,lac-.a,c.wrrr-rxa of As;�a:t+t,x era=uV1:re.,,y,.,L..xrJn•«+-tarn•re a'•err.rr 9sorn+r a,aakarrMalt7wesra 2x4 13.2 13.3 t�ssts.:te arowtrsrncezo..a:•,."x;�z�rwaesrs;a-•avegGx. ateocsenxesmmesutrrnrtr»xmruatdpeomrr,wm4snz++oaNrar 2xo 12.9 13.1 rS3e oe:A W tams?}w:.a 3r.+{e.acx€z,• R-30 _ =o-+c rill as^jrEar,:.tir7:.:-:••:hsu,3_es,rdns.•,r-•m�+a:;,ra c �'ar.Lc_cce-.er:aics i'.+a.Araeat usrSt*arsair rrg.!�CaTa!KR er c9aiea Aeasat+ra 2x8 12.6 129 ' 'S�-0 •7rna r 11.3 2x4 11.4 U :•, ,:erg'-a asrz.-r -.t R-26 2x6 11.0 112 Builder's Insulation Statement Jet Stream Ultra has been installed on conformance w the included included recommendations to provide a thermal resistance of 2x8 108 S 1.0 .. 2x4 - 9 3 9 5 R-Value Thickness R-22 2x6 9.1 9,3 Attic Area R- at !aches 2x8 8 8 9.1 Sloped Ceilings R- at Inches 2,4 TS BA Wa'.ls R- at Inches R-19 2x6 77 7.9 Floors(over an unheated crawl space) R- at Inches 2x8 7A 7.7 Drawl Space Per' star R- at Inches ff .3 54 R-13 0 5,2 Date Installed 8 5.0 Blo ns lation has been in in conformance vrith the above r ;( r��tvide an R vakee at: .3 4.4 R-} using tJ bags of this insulation to cove * Niue feet of area R-11 .1 4.3 at a minimum thickness of _inches. .8 4,1 YV ut rnt.oAmeM !nsuW:4n Gonrrapnr Isgna!a ) r-;rr- �•:u'a-s�.�_�ct::�r Cis%+tsY !L.'+ ..,��a--------.""_'""'--sy� ---t t -in Ut 1~L-irrr OVrrtOUAaO HCme SukfM(l,O'-mule) r..rr:tver7sn Pres,Arc'* ._ `. _._. �.�.� __ �___.____--a._._--•-_ _.__�,_.- ._- ._..�._......�� • . . .a,:a:,e F^pee ,x„r,r The eoverage Information on this AtlicfSidewatl card applies to the entire United States(including Min nasota). www.knautinsulation.us Knaui Insulation,Inc. One Knauf Drive,Shetbyvik IN 46176 Tel:(WO)825.4434 ext.8300 FAX_(317)398-3675 2018127555 fgcpt:1977661 Rec: 1"0.00 PS: 0.00 IT: 0.00 07/30/2018 C. F. , Dpty Clerk PAULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER .07/30/2018 09:02am I of I OR BK 9764 Ps Permit No. Parcel ID No 24-26-21-0100-00000-1190 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real.property,and In accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1-.* Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 119 Street Address: 3163 Kresterbrooke Lane ZephryhIlls FL 33541 2. General Description of Improvement Single Family Residence Pool./Screen Enclosure Fence 3. Owner Information: Lennar Homes,LLC. Name 4600 W Cypress St. Ste,200 Tampa FL. 33607 Address city State Interest in Property: Name of.Fee Simple Titleholder: N/A '(If other than owner) Address city State 4. Contractor: Lennar Homes, LLC Name - 4600 W Cypress St, Ste 200 Tampa FL,33607- Address city State Contractor's Telephone No.: 813.574.5700 -6. Surety., NIA - Name Address city State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Addresscity State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL 33607, Address city State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A. of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording.unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT MENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO'09TAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The.foregoing.instrument was acknowledged before me this 30 day of March _,by Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes, LLC (name of party a alf of whomi nsirmleent was executed). Personally Known AOR Produced Identification 0 Notary Sig(a—lure Type of Identification Produced Name(Print)%-- a- Holleran Verification Verification pursuant to Section 92.525,Florida Statutes. Under penalties of .perjury,I declare that I have read the foregoing and that the facts stated in owreffa—I 6 it are true to the best of my knowledge and belief. ELISSAMMOUMN Signature of Natural Person Signing Above Offte3rJUne 0.2020 wpdata/bcs/bcs form,, Pnod7bmTroyF&Iolnsuitnotal4wyolg Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfi.zendesk.com> Sent: Wednesday,August 8, 2018 12:48 PM To: Jacqueline Boges Subject: [Request received] 3163 Kresterbrooke Lane bp#1 9981 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/232266 ................ ...................................-..................................I.......................................................................................................... ................................................................................... ................ Jacqueline Boges Aug 8, 9:47 AM MST full service 3163 kresterbrooke lane bp#1 9981 water, sewer, water meter This email is a service from City of Zephyrhills Support . 813-780-0020 City of Zephyrhills Permit Application FakS13-780-0021 Building Department Date Received MAY 0 3 2018 Phone Contact for Permittin 813 363 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 13-574,5700 Owner's Address 4600 W.Cypress St.Ste..20.0,Tampa,FL 33607 Owner Phone Number—] Fee Simple Titleholder Name N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3163 Kresterbrooke Lane LOT# 1190 SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-1190 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN Q Q DEMOLISH P INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure Fence BUILDING S13FE F—u/R SF 3046 SQ FOOTAGE2584 HEIGHT 12 Story . . . N a`rq - a a & % 2 a - - a - aBUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL 1$ PROGRESS ENERGY Q W.R.E.C. AMP SERVICE VIPLUMBING 1$ MECHANICAL VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES 0 D BUILDER COMPANY Lermar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 14600 W.Cypress St.Ste.200,Tampa,FL 33607 License# FGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road,Tampa, FL 33613 License# I EC130054 08 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREK I Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License#1 CFC042998 MECHANICAL- COMPANY BayonetPlumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 53 yonet, FL 34674-5308 License#- CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N EN FEE CURREN A i — Address 14211 Shoal Line Nvd, Spring Hill, FL 34607 License# [ECC057991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;,R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans;Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I.dbmpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ■ . . . . . . . . . . Directions: Fill.out application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement Is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E. LOT 119 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT FT. EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA =__L09_3___SQ. FT. ENTRY FT. n UNDERGROUND FOOTER, STEM WALL, AND GARAGE =__±ZZ____SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR COVERED LANAI FT. SHOWN. PATIO =_!!--SQ. FT. CONC. DRIVE =—AQL--SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND L;j NOTES TAKE PREFERENCE, A/C & CONC PAD FT. PRIVATE SIDEWALK FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS PAGE INDICATES THAT PLAT IS IN 2034 —SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO SOD FT. CHANGE AND/OR REVISION. OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY =__j.9_7Q._89_SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON = Lj±_SQ. FT. PUBLIC SIDEWALK _ FT. STRUCTURE TIES SHOWN HEREON DENOTES SOD FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. TOTALS PRELIMINARY DRAWING: AREA FT. THIS PLAN IS FOR PERMITTING PURPOSES DRIVEWAY FT. ONLY, NOT FOR CONSTRUCTION. VERIFY SIDEWALK FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SOD S Q. FT. NOTES: A LEGEND: LOT GRADING TYPE = A _ --= PROPOSED DRAINAGE FLOW (00.00) PROPOSED GRADE PROPOSED PAD ELEVATION N/A E-00.00 = EXISTING GRADE FRONT SETBACK = 20' 10- DRAINAGE/UTILITY EASEMENT SIDE SETBACK = 10' LOT 105 REAR SETBACK 10* HIDDEN RIVER PHASE ONE A 's LOT 120 (PLAT BOOK 74, PAGES 101-121) .0 0. PLAT BOUNDARY S 78-1 7'12" 10.00, 40 40('V12 25.00, .......... LOT 119 LOT 106 HIDDEN RIVER PHASE ONE A 0 (PLAT BOOK 74, PAGES 101-121) x 0 Al 0 to p A /44J z............ Q N. A 4,j A PLAT 9 BOUNDARY • 19, 137 iz, LOT 118 770 00, C, DESCRIPTION: A PROPOSED: LOT 119, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B" LOWEST FLOOR ELEVATIONS: AS RECORDED IN PLAT BOOK __ PAGES --- THROUGH LIVING AREA: 72.35' OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A PC(P) ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL I CURVE RAP C CHORD BEARING DELTA PRM(P) CO go!g§00, 2, 230.44- S 45*23'43" W 38*26'28" 230.4 . 3 DATUM OF 1929. MEAN SEA, 87.50 LEVEL= 00.00 FT. I C52 1 240.00- 1 60.16' 60.00 APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 LEGEND: (C) ALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, rk= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= = C CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, MR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: Sms Square Feet: 8133.71 t LE'NNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30- NOT VALID WITHOUT THE SIGNATURE AND jDate of Survey: THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04./19/2018 RTM R, BEACH DATE LICENSED SURVEYOR AND MAPPER FLORI REG. LAND SURVEYOR No. 2984 LB#4493 Revisions: r MET I EL.. 127 A 0 4M 6 98 A L LU 1 4 FF EL EL FFFr;L7 All A 126 IZ'A' ter zA I 34TFEL102 73=A1.42 IL ------ At A IH-3OL ----------I07 AV YE] SCALEley-Hom AEZ NOT EDasa'-HORN AND ASSOCIATES, INC. DRAWN BY1-0400 FAX (1114) -78Z-497E CHECHED BY ff 'Ph EL 7 19 Al 7 EL w I­ 7MM7 �A I FFa IJA 7A r 7. -1 FF EL VIR7 =A 'F 72 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE,FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3163 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: (L Owner: Lennar Homes Jurisdiction: 611600 ` Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:.2nd Floor 6 218.6 a. U-Factor: Dbl, U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.56 a.Central Unit 18.0 SEER:15.00 b.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1056.00 ft2 None c.other(see details) R= 433.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84 PASS Total Baseline Loads: 74.78 hereby certify that the plans and specifications covered by Review of the plans andT ;ST,q�,. this calculation are in compliance with the Florida Energy specifications covered by this 'a Code. calculation indicates compliance q /., with the Florida Energy Code. PREPARED BY: ��VG Aujl h Before construction is completed DATE: this building will be inspected for a compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes.with the Florida Energy Code.' Op'y1Z MAY 0 3 201� - OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 7� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3163 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b€N/A R= ftZ Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 \J b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2582.0 sgft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1056.00 ft2 None c.other(see details) R= 433.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84 PASS Total Baseline Loads: 74.78 I hereby certify that the plans and specifications covered by Review of the plans and, $T' this calculation are in compliance with the Florida Energy i specifications covered by this Code. calculation indicates compliance !;,,''' ,I with the Florida Energy Code. PREPARED BY: Z)ave G f�tCh Before construction is completed C' E7 DATE: this building will be inspected for � __..l;};�4_ compliance with Section 553.908 I hereby certify that this building,a designed, is in compliance Florida Statutes. .r, with the Florida Energy Code. MAY O 3 2019 OWNER/AGENT: BUILDING OFFICIA DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3163 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: _. Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types•(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz 4. Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types (1489.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ftz 6. Conditioned floor area above grade(ftz) 2582 b.N/A R= ftZ Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ftz b.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (2582.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features b.Floor Over Other Space R=0.0 1056.00 ftz None c.other(see details) R= 433.00 ftz 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84 PASS Total Baseline Loads: 74.78 I hereby certify that the plans and specifications covered by Review of the plans and -TkS�' T this calculation are in compliance with the Florida Energy specifications covered by this4 �. p Code. calculation indicates compliance /✓ with the Florida Energy Code. F+' �rrri;�'%; ,, ; ,,,•+`� n PREPARED BY: Dave A-ad h Before construction is completed DATE: this buildingwill be inspected for P compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OLj F MAY 0 3 2098 - - OWNER/AGENT: BUILDING OFFICIAL: , DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory�sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: 2575B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2582 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1093 9399.8 2 Block2 1489 11912 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes FLOORS : # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 -_ 0.3 0 0.7 2 Raised Floor 2nd Floor --_ --e 13 ft2 11 0 0 1 i 3 Floor over Garage 2nd Floor 420 ft2 11 0.2 0 0.8 4 Floor Over Other Space 2nd Flood ____ ___ 1056 ft2 0 0.2 0 0.8 j ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch 1 V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1489 ft2 N N 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block-Int Insul list Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0 5 N=>E Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0 _ 6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0 7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0 11 S=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>E Wood 1 st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening', 3 S=>W 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>E 7 Metal ; Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 10 N=>E 1 Metal Low-E Double .Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None ;I GARAGE i # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 41 ft 8.6 ft 1 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 ' INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 256.71 .339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts' 1 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 54.7 cfm 0.05 0.60 1 1 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 74.5 cfm 0.05 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling I [[ ]]Jan [[ I]Feb [[ ]]Mar [ ]Apr [[ ]May [X]Jun ri Jul [X]Aug n Sep [ ]Oct [ ]Nov [ ]Dec Heating [X]Jan [X]Feb [X]Mar [ ]Apr [ ]May [ ]Jun Jul [ ]Aug SeP [ ]Oct [X]Nov [X]Dec Ventin [ ]Jan [ ]Feb X Mar [X]A r [ ]Ma [ ]Jun Jul [ ]Au Se [X]Oct [X]Nov [ ]Dec I I 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i f 5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ftZ 6. Conditioned floor area(ftz) 2582 b.N/A R= ftz 7. Windows" Description Area c.N/A R= ftz a. U-Factor: Dbl,U=0.54 71.25 ftz 11.Ducts R ftz a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 b. U-Factor: Dbl,U=0.56 71.00 ftz SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl, U=0.56 33.33 ftz a.Central Unit 18.0 SEER:15.00 SHGC: SHGC=0.32 b.Central Unit 24.0 SEER:15.50 d. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency SHGC a.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft EF:0.95 b.Floor Over Other Space R=0.0 1056.00 ftz c.other(see details) R= 433.00 ftz b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) .�0 ' S(;4T1?o.' . in this home before final inspection. Otherwise, a new EPL Display Card will be completed w�",,''f� `��;,•'0;;,• based on installed Code compliant features. 14 Builder Signature: Date:. 05/02/18 ' Address of New Home: 3163 Kresterbrooke Lane City/FL Zip: ZeFh�rhills,F1 33540 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 9:00 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 r ' Buildin Anal $1$ Job: 2575B1 sf ADS Carrier g y Date: 5/1/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.5 5191 31.9 ucts Glazing 30.2 2683 16.5 nfiltraton Doors 21.2 432 2.7 wads Ceilings 1.7 60 0.4 Floors 4.1 4478 27.5 Infiltration 1.9 2039 12.5 Ducts 1400 8.6 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors Other Adjustments 0 Total 16284 100.0 • • Component Btuh/ft2 Btuh % of load Walls 2.8 2641 23:2 Internal Gains Glazing 56.3 5004 44.1 wall Doors 16.6 338 3.0 Ceilings 2.0 67 0.6 Ducts Floors 0 0 0 Infiltration 0.4 454 4.0 Ducts 1655 14.6 Infiltration Ventilation 0 0 Other Internal gains 1200 10.6 Doors Blower 0 0 Adjustments 0 Glazing Total 11360 100.0 Latent Cooling Load= 1237 Btuh Overall U-value= 0.150 Btuh/ft2-°F Data entries checked. - ' igf�tsq . 2018-May-01 09:33:44 ^��°t w �� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Cale=MJ8 Front Door faces: E Buildin Anal SIS Job: 2575B1 sf ADS Carrier g Y Date: 5/1/2018 upper floor By: Dave Bayonet Plumbing Heating and Air Piroject Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft' Btuh % of load Walls 3.8 4204 32.8 acts Glazing 30.2 2608 20.3 Doors 0 0 0 wall Ceilings 1.3 1868 14.6 nfiltration Floors 0 0 0 Infiltration 1.9 2299 17.9 Ducts 1846 14.4 Piping 0 0 Humidification 0 0 1 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 12825 100.0 Component Btuh/ftz Btuh % of load Walls 2.7 :3035 16.8 Wall Glazing 53.0 4581 25.4 Doors 0 0 0 Internal Gains Ceilings 1.7 2583 14.3 Floors 0 0 0 Infiltration 0.4 512 2.8 1 Ducts 2137 11.8 Ventilation 0 0 Glazing Internal gains 5213 28.9 Blower 0 0 Ducts Adjustments 0 Infiltration Total 118061 100.0 Ceilings Latent Cooling Load= 3191 Btuh Overall U-value= 0.083 Btuh/ft2-°F Data entries checked. ` -F- wrightsoft- 2018-May-01 09:33:44 ACCA Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Project Summary Job: 2575B1 sf ADS Carrier 1 Date: 5/1/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14883 Btuh Structure 9705 Btuh Ducts 1400 Btuh Ducts 1655 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh BI (none) e) 0 Btuh Piping 0 Btuh Equipment load 16284 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11360 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 942 Btuh Ducts 294 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ftz) 1093 1093 Equipment latent load 1237 Btuh Volume(ft') 9654 9654 Air'changes/hour ' 0.29 0.16 Equipment Total Load (Sen+Lat) 12596 Btuh Equiv.AVF (cfm), 47 25 Req. total capacity at 0.85 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC518AO0300 Cond 25HBC518AO0300 AHRI ref 9154643 Coil FB4CNP025L AHRI ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300: Btuh Heating output 17700 Btuh @ 47°F Latent cooling 2700; Btuh Temperature rise 27 OF Total cooling 18000' Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 30 OF Backup: Input=4 kW, Output= 15295 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. L -Fk- wrightsof[o 2018-May-01 09:33:44 •-^ �- ^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Pro ect Summa Job: 2575B1 sf ADS Carrier 1 ry Date: 5/1/2018 upper floor By: Dave Bayonet Plumbing Heating and Air Project Inf• • For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10978 Btuh Structure 15924 Btuh Ducts 1846 Btuh Ducts 2137 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12825 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18061 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2812 Btuh Ducts 379 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1489 1489 Equipment latent load 3191 Btuh Volume(W) 11912 11912 Air changes/hour 0.27 1 0.14 Equipment Total Load (Sen+Lat) 21252 Btuh Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 3600, Btuh Temperature rise 27 OF Total cooling 240001 Btuh Actual air flow 800 cfm Actual air flow 800, cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point= 16 OF Backup: Input= 3 kW, Output= 11787 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft®�� •�^-�° °•°°--��.P� Right-Suite®Universal 2018 18.0.18 RSU05714 2018-May-01 09:33:44 Page 2 ..ent\25758 sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Com liance Re ort Job: 2575B1 sf ADS Carrier p p Date: 511/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 12596 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 135% of load Latent capacity: 2700 Btuh 218% of load Total capacity: 18000 Btuh 143% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 16284 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F _ f Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 13453 Btuh 83% of load Capacity balance: 30 OF Supplemental heat required: 2831 Btuh Economic balance: -99 OF Backupequipment t e: Elec strip type: p Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. 'y Wrightsoft® 2018-May-01 09:33:44 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 AC(:;k ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 2575B1 sf ADS Carrier Date: 5/112018 upper floor By: Dave Bayonet Plumbing Heating and Air Project • For: Lennar Homes Cooling • Design Conditions Outdoor design DB: 91.3°F Sensible gain: 18061 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 3191 Btuh Entering coil WB: 62.87 Indoor design DB: 75.0°F Total gain: 21252 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 113% of load Latent capacity: 3600 Btuh 113% of load Total capacity: 24000 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 24000 Btuh 187% of load Capacity balance: 16 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model Actual airflow: 800 cfm Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. L -4-1- Wrightsoft® 2018-May-01 09:33:44 •r• a ow����mp Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Cale=MJ8 Front Door faces: E Lennar Homes-3163 Kresterbrooke Lane-3,046 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 j OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 I WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,842.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,442.97 Lennar Homes-3163 Kresterbrooke Lane 3,046 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 i FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL i TOTAL: $ PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,847.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,447.97 • i 24-26-21-0100-00000-1190 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 24-26-21-0100-00000-1190 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land ! $0 4600 W CYPRESS ST STE 200 Land $28,921 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3163 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $28,921 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,921 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 119 Taxable Value $28,921 OR 9750 PG 2604 Jurisdiction City of Zephyrhills —Li Land Detail (Card: 001 of 001) . Line Use Description�ZoningUnits ;p _L_P it ce ,Condition Value _ 1 -0100 SFR MUD 6,000.00 SF $4.50 ' 1.00 $27,000^ - 2 —�-- 0100 SFR , MPUD 2,134.00 { SF $0.90 1.00 $1,921 Additional Land Information M Acres 0.19 Tax Area 30Z FEH Code Residential Code HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ Extra Features (Card: 001 of 001) _ Line Description_ ear _ knits _V_ Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year_ Book/Page ^� Ty ep _ � D_O_R Code Condition !Amount �06/2018 9750 / 2604� Warranty Deed 05 Vacant Multi-Parcel Sale Y 09/2011 8606 / 3376_ ( Warranty Deed V 05 Vacant Multi-Parcel Sale 06/2010 8360 / 1872 Certificate of Title 12 Vacant —`$0 i I i i i . I http://search.pascopa.com/parcel.aspx?parcel=2126240100000001190 7/18/2018 PASCO COUNTY, FLORIDA - _ Permit No. _^ Date Permitted 7-I1 Cb Builder Name/Owner Name 1"A a_t, Control#' : County Parcel No. �1-'Z '-L(- jL�-p(Y � [�!D SubDiv: 141d6feA Address/Location Classificatlonrrype of Use '5 ' o TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: G;.. Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. 3, {32- . Zone No. TAZ: U' t SCHOOL IMPACT FEE - Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt ( Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined. j LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total " Exempt ❑Yes ❑ No How Determined Total Amount (J RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION t PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY i ?k i Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,piecing the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY