HomeMy WebLinkAbout18-19982 CITY OF ZEPHYRHILLS
5335-8TH STREET
.. (813)780-0020 19982
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMITJNFORMATION . = LOCATION INFORMATION -
Permit#:19982 Issued: 7/27/2018 Address: 3196 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 343,131.90 Total Fees: 18,442.97 Subdivision: HIDDEN RIVER
Amount Paid: 18,442.97 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-0830
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA, FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-363-2891
Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT
APPLICATION-FEES
BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00
MECHANICAL FEE 184.80 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,12&00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
I r�4
Inspections Requir4dW
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CO OR GNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Lennar Homes-3196 Kresterbrooke Lane-3,046 sq ft
Column ts
SO. FEET PRICE
MAIN OR LIVING: 3,046 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER:
VALUATION $ 343,131.90
FEE SHEET $ 1,760.00
ADDRESS $ 30.00
DRIVEWAY1 $ 45.00
BUILDING: $ 1,870.20
ELECTRICAL: $ 396.00
PLUMBING: $ 264.00
MECHANICAL: $ 184.80
SUB-TOTAL $ 2,715.00
TOTAL $ 2,715.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER .$ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,842.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68'
1% $ 36.32
TOTAL: $ 18,442.97
jgp���y
P SCO COUNTY, FLORIDA
Permit No.
Date Permitted
Builder Name/Owner Name ze", Aft6p Control#' "
County Parcel No.
31 f�
Address/Location
is-.- .
Classiflcation(rype of Use '51
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
Exempt. ❑Yes ❑ No How Determined
f .
impact Fee Amount $- 3r
�i 3y Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House AmountZ-
(057) Mobile Home
(058) Other Residential
23) Collection Fee
Exempt 6 Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 76 f'5to
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By iG ! ' -�' _ Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
\ 24-26-21-0100-00000-0830 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, July 14, 2018
Parcel ID 24-26-21-0100-00000-0830 (Card: 001 of 001)
Classification 00.-,Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $27,540
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3196 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540
Just Value $27,540
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 83 Taxable Value $27,540
OR 9750 PG 2604
Jurisdiction
City of ZephYrhills
Land Detail (Card: 001 of 001)_
Line 1_Usse Descripti n oning Units IType 1price _Icondition Ualue
1 _�I 0100 SFR I MPUD 6,000.00 SF $4.50 0 $27,000
2 0100 I SFR MPUD 600.00 SF $0.90 1.00 j $540
Additional Land Information_
Acres 0.15 Tax Area 30ZH Code -- Residential Code HDRVLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 0_01)
Line IDescription ___Year � ---iynits Value
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page~ Type ___DOR CodCondition Amount
06/2018 9750 / 2604 Warranty Deed 05 Vacant i Multi-Parcel Sale_
09/2011 8606 / 3376 Warranty Deed _ 05 Vacant Multi-Parcel Sale _
06/2010 8360 / 1872 Certificate of Title 12 Vacant $0
i
I
http://search.pascopa.com/parcel.aspx?parcel=2126240100000000830 7/18/2018
dingle Family fiwvellir g 1
Plan Review Coniments: : .
.1. F:F.8-shall be.a minimum:o.f 8" above the.road::elevation and:an engineeredsite plan:
2. Lots.shall be graded:to comply with:R401,3:of the RRC:
3. .6trrpaction test re uired'if 24"�or more o f fill dirt is brought in at'an .:one" lac
4; Tie in�survey required before pouring concrete.`
g Y p
- : 5: Driveways require.a R.O.W:use ermrt: All 4 sides.of driveway thru the sidewalk shall'have,
p.
expansion material. . -
6. :All-Setbacks:sliail be met. : ;
7: All'property markers shall be uncovered and marked attime.of fist inspection:.
$: All A.D.A.:requirements shall.be met..
9: :No electric,.plumbing; mechanical; or.framirig shall be covered:without an inspection and
approval'first.'
:10..A11 Garages shall comply with section R302:6 of.the FRC: (Fine Separation):=
1.1: Appliances shall not be installed in-a Io.cation where_subject to mechanical damage:unless
protected-by approved barriers.. IV1303.4"of the F:B.0
12.:Waterlieaters''shall comply wifihaection:P607.3 of the F:B.C.;"
l3. Foundation supports for A1C units shall be raised'at least 3" above finished:grade. M 1308.I
14. Return air in all bedrooms.-F.B.C. MI.620:4
I5: Snioke detectors are to be installed in.accordance"with P,313;I,-of'tlie' F..B.C: .:
16.-All glazing requirements:are:to be.in,accordance with R308,4 of the F.B.C..
17.All means of egress are:.to be izi accordance.with R31 I.of the F.B.C.
18 "Green gypsum board7' shall.riot be used a. a backer in showers"or"tubs. R702.4:2 F.B:C.
.19. Cambination-type AFCI breakers are required at all locations,requiring aft AFCI type breaker.
20: Carbon iiionoxide alarms will.be required in.new construction.that,uses fossil-burning heating.'
or appI' n'' or.an:attachedgarage: They shall'be installed in accordancewith�the:F:B.C:
21., All plumbing;mechanical,.-and electrical shall be,separate from unit to unit.;.This includes all_
underground plumbing and electric.
22. All'2011.N:E.C:,Codes.'will'be,eriforced: : :
23. Tam er Resistant Rece tacles.in accordance with 406.1 I of.the 201 t N:E.C:::"
p. .= - p.
24 ln'accordance with:the,Land.Developrrient:Code, Iots shall be.sodded.before'final.at least 10.
feet around thestructure..
25: Blow door test.shall.be.provided before C.O.
26.:A.z® .0 of the eneNgy cads shall be with Rerciait at call times
27 Cogy of final'insailationr report shafl be.yravided fvitli �ernait befor.e kraal.
F.F:E.-Finished Floor:Elevation
F.B:C=:Florida Building Code 6th Edition
-
R:O.W.-Ri6t_of Way
A.D:.A-:-Americans with Disabilities Act NRC,-National.Electric Code(201:1)
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575BI sf ADS Carrier Builder Name: Lennar Homes
Street: 3196 Kresterbrooke Lane Permit Office- Q of Zephyrhflls
City,State,Zip: FL, Permit Number:
Owner Lennar Homes Jurlsdictiori: '611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4A 996.67 ft2
3. Number of units,if multiple family I c.Frame-Wood,Adjacent R=1 1.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(I 75.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor. Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor. Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor. N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R�0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84 PASS
Total Baseline Loads: 74.78
I hereby certify that the plans and specifications covered by Review of the
plans and
-4 01
this calculation are in compliance With the Florida Energy specifications covered by this
Code., calculation indicates compliance
with the Florida Energy Code. --W
PREPARED BY: &ye 44611ch Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as d igned,is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT:- MAY 0 3 2018 BUILDINGAFF1 AL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI1RESNET1ICC 380,is not greater than 0.050 Qn for whole house.
6/112018 8:59 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page I of 5
FORM R405-2017
FLORIDA'ENEkGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3196 Kresterbrooke Lane Permit Office: City of Zephyrhffls
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=1 1.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2'
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ftz
11.Ducts R ft2
7. Windows(I 75.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Flo-or,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor. Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor- N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ.' b. Conservation features
b.Floor Over Other Space 11=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84
Total Baseline Loads: 74.78 PASS
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this y_0
Code. Z S.,
calculation indicates compliance
with the Florida Energy Code. 4"
PREPARED BY: Dalle Aw'kkh Before construction is completed
DATE: this building mfili be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: MAY 0 3 2018 BUILDING Q�FICI t1111
DATE: DATE: - Z: -4 /�
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires art Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires a,n
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSIIRESNET/ICC 380,is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3196 Kresterbrooke Lane Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a,Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 74.84 PASS
Glass/Floor Area: 0.068 Total Baseline Loads: 74.78
I hereby certify that the plans and specifications covered by Review of the plans andjrYES '
this calculation are in compliance with the Florida Energy specifications covered b this P 9y P y
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Dave Aupich Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 ., =.
I hereby certify that this building,as esigned, is in compliance Florida Statutes. A'
with the Florida Energy Code. MA� ?CO-
0 3 2018
OWNER/AGENT: BUILDING OF CIA :
DATE: A DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
� S ,
FORM R405-2017
PROJECT
Title: 2575B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2582 Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle' 90 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1093 9399.8
2 Block2 1489 11912
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes
2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 0.3 0 0.7
2 Raised Floor 2nd Floor 13 ft2 11 0 0 1
3 Floor over Garage 2nd Floor __e 420 ft2 11 0.2 0 0.8
4 Floor Over Other Space 2nd Floor 1056fft2 0 0.2 0 0.8 i
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1489 ft2 N N
5/1/2018 8:59 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
I
r �
FORM R405-2017
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 N=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0
2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0
_ 3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0
-4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0
5 N=>E Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0
6 W=>N Garage Frame-Wood 1st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0
7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0
9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0
11 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
3 S=>W 11 Metal Law-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None
4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None
6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 6 in grapes/blinds None
9 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
10 N=>E 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 420 ft2 420 ft2 41 ft 8.6 ft 1
II
I
5/1/2018 8:59 AM EnergyGauge(D USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
r ,
FORM R405-2017
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 256.71 .339 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 54.7 cfm 0.05 0.60 1 1
2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 74.5 cfm 0.05 0.60 2 2
TEMPERATURES
Programable Thermostat:Y ] Ceiling Fans:May Jun Jul rjCoolin
Jan Feb
Dec
Heating Jan Feb X]Mar Apr May rl Jun rl Jul Aug Se rj p Oct Nov Oct Oct X�Nov Nov € DecVenting Jan Feb X Mar Jun Jul Aug Sep
I
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
r
FORM R405-2017
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
1
I
5/1/2018 8:59 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2617
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area(ft2) 2582 b.N/A R= ft2
7., Windows" Description Area c.N/A R= ft2
a. U-Factor. Dbl,U=0.54 71.25 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
b. U-Factor: Dbl,U=0.56 71.00 ft2
SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency
c. U-Factor. Dbl,U=0.56 33.33 ft2 a.Central Unit 18.0 SEER:15.00
SHGC: SHGC=0.32 b.Central Unit 24.0 SEER:15.50
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 17.7 HSPF:8.50
Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 EF:0.95
b.Floor Over Other Space R=0.0 1056.00 ft2
c.other(see details) R= 433.00 ft2 b. Conservation features
None
15.Credits Pstat
certify that this home,has complied with the Florida Energy Efficiency Code for Buildingk1E:S
Construction through the above energy saving features which will be installed (or exceeded) p o._
in this home before final inspection. Otherwise,,a new EPL Display Card will be completedry�`,
based on installed Code compliant feat S.
Builder Signature: Date: 05/02/18 94.. y '
*.. '
Address of New Home: 3196 Kresterbrooke Lane City/FL Zip: Zephyrhills,FL 33540..' �,::` v5
OD iM1IE
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/1/2018 9:00 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
Building Analysis Job: 2575B1 sf ADS Carrier
g Y Date: 5/1/2018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(OF) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 .Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 5.5 5191 31.9 ua5
Glazing 30.2 2683 16.5 nfiltration
Doors 21.2 432 2.7 Wall
Ceilings 1.7 60 0.4
Floors 4.1 4478 27.5
Infiltration 1.9 2039 12.5
Ducts 1400 8.6
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Doors other
Adjustments 0
Total 1 16284 100.0
• • •
Component Btuh/ft2 Btuh % of load
Walls 2.8 2641 23.2 Internal Gains
Glazing 56.3 5004 44.1 Wall
Doors 16.6 338 3.0
Ceilings 2.0 67 0.6 Ducts ,
Floors 0 0 0
Infiltration 0.4 454 4.0
Ducts 1655 14.6 Infiltration
Ventilation 0 0 Other
Internal gains 1200 10.6 Doors
Blower 0 0
Adjustments 0
Total 11360 100.01 Glazing
I
Latent Cooling Load= 1237 Btuh
Overall U-value= 0.150 Btuh/ft2-°F
Data entries checked.
wri-ghtsoft® 2018-May-01 09:32:25
^�•k w �• Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W
Buildin Anal $I$ Job: 2575B1 sf ADS Carrier
g y Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
i
For: Lennar Homes
Design C• • •
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range�°F) - 14 ( L ) Method Simplified
Wet bulb(°F - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Walls 3.8 4204 32.8 ucts
Glazing 30.2 2608 20.3
Doors 0 0 0 Walls
Ceilings 1.3 1868 14.6 nfiltraa°n
Floors 0 0 0
Infiltration 1.9 2299 17.9
Ducts 1846 14.4
Piping 0 0
Humidification 0 0 Ceirings
Ventilation 0 0 Glazing
Adjustments 0
Total 12825 100.0
Component Btuh/ft? Btuh % of load
Walls 2.7 3035 16.8 walls
Glazing 53.0 4581 25.3
Doors 0 0 0 Intemal Gains
Ceilings 1.7 2583 14.3 1
Floors 0 0 0
Infiltration 0.4 512 2.8
Ducts 2137 11.8
Ventilation 0 0 Glazing
Internal gains 5270 29.1
Blower 0 0 Ducts
Adjustments 0 Infiltration
Total 18118 100.0 Ceilings
i
Latent Cooling Load= 3241 Btuh
Overall U-value= 0.083 Btuh/ftz-°F
Data entries checked.
wrightsoft- 2018-May-01 09:32:25
^�^•�m- •w�- - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...ent12575B sf ADS template 1.5-2 ton Canler.rup Calc=MJ8 Front Door faces: W
Project Summary Job: 2575B1 sf ADS Carrier
J Date: 5/1/201 S
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Notes:
Desicin Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14883 Btuh Structure 9705 Btuh
Ducts 1400 Btuh Ducts 1655 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none
- (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 16284 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 11360 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 942 Btuh
Ducts 294 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1093 1093 Equipment latent load 1237 Btuh
Volume(ft3) 9654 9654
Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12596 Btuh
Equiv.AVF(cfm) 47 25 Req. total capacity at 0.85 SHR . 1.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC518AO0300 Cond 25HBC518AO0300
AHRI ref 9154643 Coil FB4CNP025L
AHRI ref 9154643.
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 15300 Btuh
Heating output 17700 Btuh @ 47°F Latent cooling 2700 Btuh
Temperature rise 27 OF Total cooling 18000 Btuh
Actual air flow 600 cfm Actual air flow 600 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Capacity balance point= 30 OF
Backup:
Input=4 kW, Output= 15295 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft� 2018-May-01 09:32:25
MCA •�^ ° �� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...entk2575B sf ADS template 1.5-2 ton Carier.rup Calc=MJ8 Front Door faces: W
e
Pro ect Summary Job: 2575B1 sf ADS Carrier
1 •y Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project 1 • •
i
For: Lennar Homes
Notes:
Desi_qn Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10978 Btuh Structure 15981 Btuh
Ducts 1846 Btuh Ducts 2137 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12825 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 18118 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2862 Btuh
Ducts 379 Btuh
Central vent(0 cfm) 0 Btuh
Heating Coolingg (none)
Area(ft2) 1489 1489 Equipment latent load 3241 Btuh
Volume(ft3) 11912 11912
Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21359 Btuh
Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary
i
Make Carrier Make Carrier
Trade Trade
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AH R I ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.062 cfm/Btuh Air flow factor 0.044 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.85
Capacity balance point= 16 OF
Backup:
Input= 3 kW, Output= 11787 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
L -�- wrightsoft® 2018-May-Ot 09:32:25
• a• ^ - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W
Manual S Compliance Report Job: 2575B1 sf ADS Carrier
Date: 51112018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F
Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F
Indoor design DB: 75.0°F Total gain: 12596 Btuh
Indoor RH: 50% Estimated airflow: 600 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Sensible capacity: 15300 Btuh 135% of load
Latent capacity: 2700 Btuh 218% of load
Total capacity: 18000 Btuh 143% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F. Heat loss: 16284 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier, Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Output capacity: 13453 Btuh 83% of load Capacity balance: 30 OF
Supplemental heat required: 2831 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 600 cfm
Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF
Meets all requirements ofACCA Manual S.
- wrightsoft® 2018-May-01 09:32:25
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W
Manual S Compliance Report Job: 2575B1 sf ADS Carrier
Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 18118 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.3°F Latent gain: 3241 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21359 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 113% of load
Latent capacity: 3600 Btuh 111% of load
Total capacity: 24000 Btuh 112% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 24000 Btuh 187% of load Capacity balance: 16 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
1 -Fk Wr7ghtsoft- 2018-May-01 09:32:25
nurt.N/emW4v WMawy Umpv� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
ACCK ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: W
- � I IIII{I111811111{IIII II{�{8111 III{j IIIII I{II{IIIII Illl IIII ;
2018127554
:Rcpt:1977661 Rec: 10.00 II
IDS: 0.00 IT: 0.00
07/30/2018 C. F. , DptY Clerk
OAULA S.0'NE1L,Ph.D.PASC0 CLERK & COMPTROLLER
07/30/2018 09:02am I of I
OR BK 9764 PG 100
Permit No. Parcel ID No 24-26-21-0100-00000-0830 —
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following Information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 83
street Address: .3196 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence Pool Screen Enclosure Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W Cypress St Ste 200 Tampa FL. 33607
Address city, State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(if other than owner)
Address city State
4. Contractor: Lennar Homes, LLC
Name
4600'.W Cypress St, Ste 200 Tampa FL,33607
Address city State
Contractor's Telephone No.: 813.574.5700
5. Surety: N/A
Name
Address city State
Amount of Bond: Telephone No.:
6 Lender: N/A
Name
Address city State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W-Cypress,St;Ste 200 Tampa FL, 33607j
Address city State
Telephone Number of Designated Person: 813.574.5700
a. In addition to himself,the owner designates N/A of
toreceive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF-THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY; A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA-
COUNTY OF'PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this_10 day of March _,by
Steve Robert Smith _as Vice President (type of authority,e. cer,trustee,attorney In fact)for
Lennar Homes, LLC (name of party ument was executed).
Personally Known 2 OR Produced Identification 171 Notary Signature =!if0±f0fr11r—
Type of Identification Produced Nam-(Print) Elissaf�erah
Verification pursuant to Section 92.5215,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
�121.198ft H6LLERAN Signature of Natural Person Signing Above
,C4MMk#l0hi1FF99W
&PIresJunoll.1020-
wpdata/bes/bcs form: ftd14nNTMyF4Ifi(NUMflCe*4W74I1
r �
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received MAY 0 3 2018 Phone Contact for Permitting 1� 813 363 28
1 1 1 11111411111 �91
Owners Name Lermar Homes,LLC Owner Phone Number r�137574,5700
Owner's Address F600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number_ t
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 13196 Kresterbrooke Lane LOT# 0830
SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-0830
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTRR ADD/ALT SIGN Q Q DEMOLISH
P INSTALL REPAIR
PROPOSED USE SFR Q COMM OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME 0 STEEL
DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure Fence
BUILDING SIZE Fu—/RSF 3046 SQ FOOTAGE HEIGHT 12 Story
BUILDING VALUATION OF TOTAL CONSTRUCTION
io
ELECTRICAL AMP SERVICE PROGRESS ENERGY W.R.E.C.
i` 'j E�.._�buPLUMBING 1$
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING 0 SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do
BUILDER COMPANY I Lermar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN
Tampa,200 Ste Cypress Si C. yp . . , a,FL 33607
Address 4600 W. mp EGC1518166 License# F
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skipper Road,Tampa, FL 33613 License# I ECI 3005408
09
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5368, Bayonet, FL 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating.&AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
—1 I
Address P.O. Box 5308, Bayonet, FL 34674-5308 License# CAC058062
OTHER COMPANY
SIGNATURE LZ N
REGISTERED Y/ N FEE CURREN L__j
Address F 4211 Shoal Li Blvd, Spring Hill, FL 34607 License# I CCCO57991
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed,
Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Direction::
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
PLOT PLAN SKETCH ONLY NOT A BOUNDARY 'SURVEY SEC. 24 TWP. 26 S, RNG. 21 E.
LOT 83 , • ` BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
LOT = 6600.00-SQ. FT. EASEMENTS AND RESTRICTIONS OF-RECORD.
LIVING AREA =_1093_-SQ. FT.
ENTRY =_35 __SQ. FT. o UNDERGROUND FOOTER, STEM WALL, AND
GARAGE =_427___SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR
COVERED LANAI =_N[A----SQ. FT. II SHOWN.
PATIO =_23 ---SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
CONC. DRIVE =_408 _SO. FT. ,;_i NOTES TAKE PREFERENCE.
A/C & CONC PAD =_18 SQ. FT. ¢
PRIVATE SIDEWALK =-31-----SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS =-31-----7 PAGE INDICATES THAT PLAT IS IN
= 2035---SQ. FT. t PRELIMINARY STAGE AND IS SUBJECT TO
SOD = 4565--SQ. FT. CHANGE AND/OR REVISION.
OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
RIGHT OF WAY =_720 00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
DRIVE APRON = _144____SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK =-24o___-3Q. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
SOD =_336___SQ. FT. TO PROPERTY LINE.
TOTALS PRELIMINARY DRAWING:
AREA = 7320.00-SQ. FT. THIS PLAN IS FOR PERMITTING PURPOSES
DRIVEWAY = 552 SQ. FT.
ONLY, NOT FOR CONSTRUCTION. VERIFY
SIDEWALK =_271-----SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
SOD =_4901 ___SQ. FT.
NOTES: LEGEND:
.LOT GRADING TYPE = A ---= PROPOSED DRAINAGE FLOW
PROPOSED PAD ELEVATION = N/A (00.00) = PROPOSED GRADE
FRONT SETBACK = 20' E-00.00 = EXISTING GRADE
SIDE SETBACK = 10' * = 10' DRAINAGE/UTILITY EASEMENT
REAR SETBACK = 10' ** = 5' DRAINAGE'EASEMENT
LAT PLAT
I B A NDAFY BOUNDARY
I
I LOT 84
.1
I25,00' S 89°36'58" E 1 10.00' ?��
25.50' o
..........I................ .
46.50................... o
WN a0 O
Z I D O
w0— O 0 ,00° I ° . °p° �
`/ o_ (D to
3.VWi y.-. ON a — 'I Q ,a 0 10 c L
Q x 2 W I ° V)�m a 2 LOT 324
as N ••• •••••1.... .. .. O N w o HIDDEN RIVER PHASE ONE A
Q x,o I 0 20.50' 0 z ¢ v LOT 83 N (PLAT BOOK 74, PAGES 101-121)
0 n 20.50' a a w Cr
—Y N .........I.......... C.7
LLWm I O * I 4 0 '
3'-�„ ¢o a ° 25.50' ❑ 46.50' O
W= I................ o ....................... V)
o_ N �j 8N 9 36'58" W 1 10.00'
i�-Ci—PRM(P)
..
.... ....... .
N 89'36'58"W
25.00' LOT 82
(TYP)
I
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 72.80'
DESCRIPTION: GARAGE AREA: N/A
LOT 83, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", ELEVATIONS REFERENCED TO
AS RECORDED IN PLAT BOOK PAGES ___ THROUGH NATIONAL GEODETIC VERTICAL
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. DATUM OF 1929. MEAN SEA!
LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, c= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE, W F= WOOD FENCE R = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6600.00 t LENNAR HOMES
SURVEYORS AND MAPPERS Checked By:
911 WEST ST. PETERSBURG DRIVE
ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30'
NOT VALID WITHOUT THE SIGNATURE AND Date of Survey:
THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM J N BEACH DATE
LICENSED SURVEYOR AND MAPPER LORIDA G. LAND SURVEYOR No. 2984 LB 4493
Revisions:
'ON n3romci
IWO
MW
�.:�c-�.. �-�� ;�� ,..m�"""`- ;�;;• ;••'' tit ������ '� 4A • , �o-
IV4"grog.. °"' • � 8�,fA�
SIM
V Coo x b8 IY' 11'
ze on
y e
.................. -isdd 1. "R
aw
en
c
as
�� ,
r r. t 00L13
PASCO COUNTY
ASC( DEVELOPMENT SERVICES
J 1 A. �:_. f 8731 Citizens Drive Date: 11/2/2018
COUNTY FLO1tIDA� New Port Richey,FL 34654
Orera Sirc:r...I01110,yr PIACES. 727-847-2411
* NOT A PERMIT
Receipt#: 1806262
FEE DESCRIPTION ACCOUNT CODE UNITS. INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1399905 $12.58 $12.58 1806262 11/2/18
Waste Single Family
Permit 19982.
TOTALS: $12.58 $12.58
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1806262 Check 1076130 556 BCCCP05W 11/02/2018 $12.58
Total Payments: $12.58
Pavor Address Phone
Lennar Homes,LLC
Comments:
HiddenrRiver broth Lane l�q
Hidden River subdivision
While you will be paying your bill with Pasco County Development Services,the full amount of the credit ear ore-check fees,NOT shown above,Is collected by
First Billing payment services.
I '1
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6.rpt 11/2/2018 Page 1 of 1
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, August 8, 2018 11:36 AM
To: Jacqueline Boges
Subject: [Request received] 3196 Kresterbrooke lane by#19982
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/232228
......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
Aug 8, 8:36 AM MST
full service 3196 kresterbrooke lane water,sewer, water meter by#19982
This email is a service from City of Zephyrhills Support .
i
i
I
1
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 3196 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC
I
ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200
Subdiv: HIDDEN RIVER TAMPA, FL 33607-4099
Parcel: 24-26-21-0100-00000-0830 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19982
Date: 11 14/2018
d
ISSUED Y: % BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE