Loading...
HomeMy WebLinkAbout18-19983 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19983 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - LOCATION.INFORMATION Permit#:19983 Issued: 7/27/2018 Address: 3172 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING = ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 18,442.97 Subdivision: HIDDEN RIVER Amount Paid: 18,442.97 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-0810 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-363-2891 Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 16 ,3 V-k xis Inspections ReWfed FOOTER 2ND ROUGH PLUMB misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. C T CTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received MAY 0 3 2018 Phone Contact for Permitting 1 813 363 2891 Lennar Homes,LLC umber 813.574.5700 Name Owner Phone N Owner's Owner's Address 4600 W.Cypress"St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 13172 Kresterbrooke Lane LOT# 10810 SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-0810 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED n d II NEW CONSTR ADD/ALT SIGN DEMOLISH INSTALL F--1 REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure i Pence BUILDING SIZE I U/R SF 3046 SQ FOOTAGE HEIGHT 12 Story . . . . . . . . . . . . . . . . . . . . . BUILDING. . . . . . . . . . . .I' VALUATION OF TOTAL CONSTRUCTION) 11-2E, 1-20 1 ELECTRICAL 1$ AMP SERVICE PROGRESS ENERGY W.R,E.C. PLUMBING 1$ 7 10MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION lj =GAS ROOFING = SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do . . . . . . . . . . . . . . . . . . . . . BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 4610 W.Cypress St Ste.200,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY =Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN LY/N - F— Address 1034 Ski per Road,Tampa,a, FL 33613 License EC13605408 PLUMBER COMPANY Bayonet Plumbing,-Heating &AC, Inc SIGNATURE REGISTERED Y1 N FEE CURREN Address FP—.0 Box 8308, Bayonet, FL 34674-5308 License#-I-CFC042998 MECHANICAL _� COMPANY Bayonet Plumbing-,--Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. icense#o. Box 308, Bayonet, FL 34674-5308 CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address 14211 Sh(61 Line Blvd, Spring Hill, FL 34607 License# Fc cC057991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater-Plans wt Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater'Plans wl Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet,compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I I I I I I I Directignt Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is requited. (A/C upgrades over$7600) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same. OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) priveways-Not over Counter if on public roadways..needs ROW PLO T PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E. LOT 81 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89*40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE N TITLE SEARCH. ALSO SUBJECT TO SETBACKS; ON LOT AREA CALCULATIONS EASEMENTS AND RESTRICTIONS OF RECORD. LOT =-218L-2-L-SQ. FT. LIVING AREA =-1093---SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND ENTRY =--�-5---SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR GARAGE = 42Z---SQ. FT. SHOWN. COVERED LANAI =—�.LA—SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND PATIO =--?3----SQ. FT. NOTES TAKE PREFERENCE. CONC. DRIVE = FT. A/C & CONC PAD =-18--SQ. FT. 6 DESCRIPTION NOT CONTAINING PLAT BOOK AND PRIVATE SIDEWALK SO, FT. co PAGE INDICATES THAT PLAT IS* IN IMPERVIOUS =--?-8--% t PRELIMINARY STAGE AND IS SUBJECT TO =-1031--SQ. FT. CHANGE AND/OR REVISION. SOD 11—9SQ. FT. CERTAIN DATA SHOWN HEREON BASED ON OFF LOT AREA CALCULATIONS ENGINEERING PLANS PROVIDED BY CLIENT. RIGHT OF WAY =__L76:_qg__SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES K DRIVE APRON FT. PUBLIC'SIDEWALK =--22-8SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD _ FT. TO PROPERTY LINE. PRELIMINARY DRAWING: TOTALS THIS PLAN IS FOR PERMITTING PURPOSES AREA 7832.23 SQ. FT. ONLY, NOT FOR CONSTRUCTION. VERIFY DRIVEWAY =--5�5_4--SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SIDEWALK FT. SOD 5423--SQ. FT. LEGEND: NOTES: ---= PROPOSED DRAINAGE FLOW LOT GRADING TYPE = A (00.00) = PROPOSED GRADE PROPOSED PAD ELEVATION = N/A E-00.00 = EXISTING GRADE FRONT SETBACK = 20' N 89'36'58 W ,--PRM(P) 10- DRAINAGE/UTILITY EASEMENT SIDE SETBACK = 10' N, 25.00' REAR SETBACK = 10' .... ........ I CL 0 W PLAT LOT 82 BOUNDARY S -"" 05'83 -'49 E 110.00, 5 ......... '97- ... 2 di(8 I 03• ...........-4, ................. 0.50, -4 s. a- Uj 0z 0 I 4D 0 LOT 81 N 79*00-03. LOT 324 HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) 0 ............ 46.07, At .................. LOT 80 0 PROPOSED: DESCRIPTION: i LOT 81, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", LOWEST FLOOR ELEVATIONS: LIVING AREA: 72.45' AS RECORDED IN PLAT BOOK ---, PAGES --- THROUGH --- GARAGE AREA: N/A OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO I CURVE I RADIUS I ARC I CHORD I BEARING DELTA NATIONAL GEODETIC VERTICAL I C31 1 510.00- 1 72.92- 1 72.86- 1 S 1 Ag-57" W OF 11-32" C42 40000' 57.19- 1 57.14' N 10'59-57-- E 08711 DATUM OF 1929. MEAN SEA I C43 i 400t0' 45.51- 1 45.49- N 03-3W37" E 06-31-09" LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: '*X" COMMUNITY PANEL'NO. 120230 0460 *b EFFECTIVE DATE: 9/30/1992 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= 1CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED,•E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: sms Square Feet: 7156.21 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JR8 ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: Ira NOT VALID WITHOUT THE SIGNATURE AND Date of Survey; 'At-, THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM JO J EACH DATE LICENSED SURVEYOR AND MAPPER P ORIDA R LAND SURVEYOR No. 2984 ILB#4493 Revisions: LLS 6 127 A EL 2f rF�FEL I A 126 :k A h 90 z E7L r rF 2 A EL kSE. I 125 37 A w T?4 gEoL FFM n71 4,F 1 FA e—sL1 i I EL 714� 123 73M ,1 FFEL 1 140 \7426 25 I FFEL 278 1 FEL7 r FF EEML A 4 A 139 A A 'o .............. .. ..... ........ nm. FFF K,I 41 A I FFEL I 316 :.� ` 121 83 1 -142 \rj=7 A \aal I A 4. ,dq A 120 A 82 L OW FF E7L �A M FF EL r-Ff'-E 7L A FFM. Vim/ 31 11 7, 1 ..L i FFEL I =Aar 31 3�...... A 146 A. I FF a j n45 — " ( rA i A 7 312 - 146 pF EL FF EL A 71.w/ Ko* FCK_ ElY SHE 147 - Aw- DATE HIDDEN RIVER SUBDIVISION . 06/20/06 PROJECT W. 049767000 ZHILLS FLORIDA L FFIL T MID EL ' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3172 Kresterbrooke Lane Permit office: City _4k hyrhills City,State,Zip: FL, Permit Number: ��Jf3 Owner. Lennar Homes Jurisdiction. 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1491.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 "c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor. Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00 b.Central Unit 24.0 SEER:15.50 c. U-Factor. Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems S. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1051.00 ft2 None c.other(see details) R= 440.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.91 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans andT_ this calculation are in compliance with the Florida Energy specifications covered b this Q P 9Y P Y '',,,: Q.t, Code. calculation indicates compliance . �,,, ='=a��0''0, ..,. Dave with the Florida Energy Code. PREPARED BY: Pt; Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. . �; �.� ..._._ . Wig. _•, with the Florida Energy Code. MAY O 3 2018 oD` OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: -/r-lt - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. 5/1/2018 8:45 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-k17 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3172 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features EF:0.950 b.Floor Over Other Space R=0.0 1051.00 ft2 None c.other(see details) R= 440.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.91 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and ;Q 'CHEiSTAT this calculation are in compliance with the Florida Energy specifications covered by this' - O Code. calculation indicates compliance � with the Florida Energy Code. Dave G�l PREPARED BY: Before construction is completed DATE: this building will be inspected for fl) . compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. '0 MAY 0 3 2018 ' OWNER/AGENT: BUILDING OFFICIAL: DATE: V111, DATE: - Compliance requires lertification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. j -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house. i 5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3172 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family - Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.-50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1051.00 ft2 None c.other(see details) R= 440.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.91 PASS Total Baseline Loads: 74.82 hereby certify that the plans and specifications covered by Review of the plans andT_ S7Ar. this calculation are in compliance with thelFlorida Energy specifications covered by this Code. calculation indicates compliance, with the Florida Energy Code. var%. .?. •;:: °;. „ O' Dave Aup cGt y PREPARED BY: Before construction is completed � -•, " .-. ORA DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building,as designed, is in compliance Florida Statutes. . with the Florida Energy Code. MAY 0 3 2018 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.050 Qn for whole house. I 5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: 2575A1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2584 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1093 9399.8 2 Block2 1491 11928 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 1491 11928 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 0.3 0 0.7 2 Raised Floor 2nd Floor ____ e- 13 ft2 11 0 0 1 3 Floor over Garage 2nd Floor 427 ft2 11 0.2 0 0.8 4 Floor Oyer Other Space 2nd Floor -___ 1051 ft2 0 0.2 0 A.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1615 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1491 ft2 N N 5/1/2018 8:45 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1491 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below pe P o 1 N=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 3 S=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>S Exterior Concrete Block-Int Insul 1 st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0 5 N=>W Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0 6 W=>S Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0 7 N=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>N Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0 9 S=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 _10 W=>S Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0 _11 S=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated 1 st Floor None .2 3 6 8 20 ft2 2 N=>W Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 3 S=>E 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 4 S=>E 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 5 N=>W 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 6 S=>E 9 Metal Low-E Double Yes 0.54 0.31 : N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 7 W=>S 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>W 7 Metal Low-E Double Yes 0.56 0.28 N . 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 S=>E 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds' None 10 N=>W 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 41 ft 8.6 ft 1 I I 5/1/2018 8:45 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 2488.2 136.6 256.9 .339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 18 kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 54.7 cfm 0.05 0.60 1 1 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 74.6 cfm 0.05 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: [ Coolin Jan Feb Mar Oct Nov Dec Heating Jan II Feb Mar Apr May rl Jun rl JuApr May Jun l rj Aug r �SepE Oct Nov Dec Venting Jan Feb X Mar Jun Jul Aug Sep �xJ I I I I i I 5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 r ; FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I i I i I 5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 r FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area(ft2) 2584 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.54 71.25 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 b. U-Factor: Dbl,U=0.56 71.00 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 18.0 SEER:15.00 SHGC: SHGC=0.32 b.Central Unit 24.0 SEER:15.50 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2EF:0.95 b.Floor Over Other Space R=0.0 1051.00 ft2 c.other(see details) R= 440.00 ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building �HSr Construction through the above energy saving features which will be installed (or exceeded) tio " a Arlo` in this home before final inspection. Otherwise, a new EPL Display Card will be completed '„`°�•{ based on installed Code compliant features. Builder Signature: Date: 05/02/18 Address of New Home: 3172 resterbrooke Lane City/FL Zip: Zephytills, FL 33540 OD y� I *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 8:47 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 r Buildin Anal SIS Job: 2575A1 sf ADS carrier Y Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa Intl AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 38 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 Dry bulb(OF) 32 91 Infiltration: Daily range(OF) - 14 ( L ) ' Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • i Component Btuh/ft2 Btuh % of load Walls 5.3 5016 31.8 �� Glazing 29.2 2565 16.3 nfiltraton Doors 22.7 450 2.9 wails Ceilings 1.7 55 0.4 Floors 4.0 4329 27.5 Infiltration 1.9 1966 12.5 Ducts 1368 8.7 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors other Adjustments 0 Total 15750 100.0 Component Btuh/ft2 Btuh % of load Walls ' 2.8 2669 23.5 I Internal Gains Glazing 56.3 4953 43.6 Wan Doors 18.6 368 3.2 Ceilings 2.0 65 0.6 Ducts Floors 0 0 0 Infiltration 0.4 456 4.0 Ducts 1657 14.6 Infiltration Ventilation 0 0 other Internal gains 1200 10.6 Doors Blower 0 0 Adjustments 0 Glazing Total 11368 100.0 Latent Cooling Load= 1216 Btuh j Overall U-value= 0.150 Btuh/ft2-OF Data entries checked. 4 wri�ghtsoft® 2018-May-01 09:12:05 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ment%2575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W Buildin Anal SIS Job: 2575A1 sf ADS Carrier g Y Date: 5/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa Intl AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 38 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9 Dry bulb(°F) 32 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 3.7 4115 32.5 acts Glazing 29.2 2676 21.1 Doors 0 0 0 Wall Ceilings 1.2 1808 14.3 nfiltration Floors 0 0 0 Infiltration 1.9 2258 17.8 Ducts 1805 14.3 Piping 0 0 Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 12662 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 3100 17.4 Walls Glazing 54.0 4951 27.9 Internal Gains Doors 0 0 0 Ceilings 1.7 2598 14.6 Floors 0 0 0 Infiltration 0.4 523 2.9 Ducts 2140 12.0 Ventilation 0 0 Internal gains 4462 25.1 Glazing Ducts Blower 0 0 Adjustments 0 Infiltration Total 17774 100.0 Ceilings Latent Cooling Load= 3317 Btuh Overall U-value= 0.084 Btuh/ft2-°F Data entries checked. i i wrightsoft, 2018-May-01 09:12:05 Right-Suite®Universal 2018 18.0.16 RSUD5714 Page 2 ...ment\2575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W Project Summary Job: 2575A1 sf ADS Carrier ry Date: 611/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14382 Btuh Structure 9711 Btuh Ducts 1368 Btuh Ducts 1657 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh. none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15750 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11368 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 925 Btuh Ducts 291 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1093 1093 Equipment latent load 1216 Btuh Volume(ft') 9641 9641 Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12584 Btuh Equiv.AVF(cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton -Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC518AO0300 Cond 25HBC518AO0300 AHRI ref 9154643 Coil FB4CNP025L AHRI ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300 Btuh Heating output 17700 Btuh @ 47°F Latent cooling 2700 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.038 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 31 OF Backup: Input=4 kW, Output= 15295 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. r �- wrightsoft® 2018-May-01 09:12:05 -^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCX ..ment\2575A sfADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W Project Summary Job: 2575A1 sf ADS Carrier J •y Date: 5/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 32 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10857 Btuh Structure 15634 Btuh Ducts 1805 Btuh Ducts 2140 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12662 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17774 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2943 Btuh Ducts 374 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftZ) 1491 1491 Equipment latent load 3317 Btuh Volume(ft') 12077 12077 Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21091 Btuh Equiv.AVF(cfm) 54 29 Req. total capacity at 0.85 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400, Btuh Heating output 24000 Btuh @ 47°F Latent cooling 3600' Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.063 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point= 17 OF Backup: Input= 3 kW, Output= 11787 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _14,1- =i0 tsoft® 2018-May-01 09:12:05 �^ w�° - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..ment12575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 2575Al sf ADS Carrier Date: 511/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project-Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 11368 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.2°F Latent gain: 1216 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 12584 Btuh Indoor RH: 50% Estimated airflow: 600 cfm i Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 135% of load Latent capacity: 2700 Btuh 222% of load Total capacity: 18000 Btuh 143% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 32.1°F Heat loss: 15750 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 13793 Btuh 88% of load Capacity balance: 31 °F Supplemental heat required: 1957 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 4.5 kW 97% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. -�- wrightsoft® 2018-May-01 09:12:05 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ment\2575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 2575A1 sf ADS Carrier Date: 511/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 17774 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.2°F Latent gain: 3317 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 21091 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 115% of load Latent capacity: 3600 Btuh 109% of load Total capacity: 24000 Btuh 114% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 32.1°F Heat loss: 12662 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 24000 Btuh 190% of load Capacity balance: 17 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model Actual airflow: 800 cfm Output capacity: 3.5 kW 93% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. i - wrightsoft® 2018-May-01 09:12:05 Right-Suite®Universal 2018 18.0.16 RSU05714 AOM Page 2 ...ment12575A sf ADS template 1.5-2ton Canier.rup Calc=MJ8 Front Door faces: W Lennar Homes-3172 Kresterbrooke Lane-3,046 sq ft Column SO. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,842.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,442.97 Lennar Homes-3172 Kresterbrooke Lane 3,046 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,847.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,447.97 ellSin leFamil g in g Plan Review Comments.1: F.F.E. shall be:a minirnum:of 8 above.-the road,elevation and an engineered site plan. I Lots shall be graded.to.comply withR401.3 of the F.B.C: .: 3.: Compaction:test required.if 24" or more:of,-f ll dirt is.brought in:at any one place: .4:. :Tie in.survey required before pouring concrete. 5.:_ Driveways:require a R.O.:W. use permit:: All 4:sides of driveway.thru the sidewalk shall-Have. expansion material. 6._ All setbacks shall be met:. .7. All.property:markers shall be uncovered and marked.at time of first.'inspection: .8:. All A.D.A. requirements shall be met. . 9.: No:electric;plumbing,_mechanical;.or framing shall be covered without an;inspection and approval first. M All Garages shall_comply:.with.section R302;6:of the F.B.C:-(Fire Sbparation).. 11:Appliances=shall not be installed in a location where subject to:rriechariical damage unless protected:by approved barriers. M303A of the F.B:C- 12. Water heaters shall comply:with section:P607.30.f the F.R.C. 13. Foundation supports for.A/C units.shall'be raised at least 3"above finished-grade. M1308,1. - 14. Return air in all bedrooms.:F.B.C. M1620.4- 15: Smoke detectors are to be in'stalled-in accordance:with:R31.3.1 of theT.B_.C. -: : .16::All glazing requirements are..to be in accordance with R308.4,of the F.B.C. . 17.All means of egress are d.be- in-accordance with R31 Lof the F:B.C. .. : . 18. ." gyp Green sum board,� .shall not be used:as a backer:in:showers:or tubs. R702.42 F.B.C.- . . 19..'Combination-type AFCI breakers are.required.af all,locations requiring:an AFCLtype breaker: 20:.Carbon monoxide alarms will be required in.'new:construction that uses_fossil-burning heating :or appliances or an attached garage. They shall be.installed in accordance with the P.B.C.. :..21.All plumbing, mechanical,:and electrical shall:be separate from unit to.unit: This includes all. - underground plumbing-arid electric: _ . 22.. All 2016.N.E:C. Codes will.be enforced.. 23: Tamper-Resistant Receptacles in accordance with 406.11 of-the 2016 N.E:C :- - . . .24::Iii accordance:.with the Land.Development.Code, lots shall be sodded before final of lea_st 10 feet around:the structure._ - 25. Blower door:test and blown iri.insulation card shall be provided before C:.O: 26-A copy ofthe MerjE cdcls.shall be with permit.at all times. 27."-Copy of final insulation report shall be:provided-with:permit before:final F.F:E.-Finished Floor Elevation F B.C=Florida Building Code 6f'Edition- R.O:W:-Right:ofWay A:D.A:-Americans with.Disabilities-Act N.E.C.-.National Electric Code(2011.) PASCO COUNTY, FLORIDA Permit No. 1619 Date Permitted 7-73 Builder Name/Owner Name /7UWt Q' Control#' County Parcel No. L`Z -��- 100,015WO-OL'�1_6 SubDiv: n Ae j r` 3(� z ,? Address/Location <. Classification/Type of Use 61,Y1 TRANSPORTATION IMPACT FEE Rate: Sq.R Unit: ' Exempt ❑Yes- ❑ No How Determined t, Impact Fee Amount $. c31 6 c32 Zone No. TAZ: SCHOOL IMPACT FEE —7 Account (056) Single-Family Detached House Amount $ _��, (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt a Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation.Credit Recreation Total Zone TOTAL AMOUNT $ C 7 6 9� u' Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE j BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY j i I Acknowledgement below does not Imply acceptance of concurrence,-but simply receipt of a copy of this form,placl l g the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0100-00000-0810 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 24-26-21-0100-00000-0810 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $28,040 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3172 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $28,040 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,040 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 81 Taxable Value $28,040 OR 9750 PG 2604 Jurisdiction City.of Zephyrhills Land Detail (Card: 001 of 001) Line -- Use DescriptionZ n g Units IType Price__ Condition Value T_ 1 0100 SFR MPUD 6,000.00 SF $4.50 1 1.00 $27,000 2 0100 SFR j MPUD 1,156.00 SF $0.90 1.00 $1,040 Additional Land Information Acres — 0.16�rTax Area 30ZH FEMA Code - Residential Code HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line Description ear — ,Units Ivalue No Extra Features j Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type _ _ DOR Code lCondition Amount 06/2018 _ 9750 / 2604 Warranty Deed 05 ^�- Vacant Multi Parcel Sale _ 09/2011 8606 / 3376 Warranty Deed — 05 Vacant Multi-Parcel Sale 06/2010 8360 / 1872 Certificate of Title 12 Vacant r-� $0 i i I i I I� http://search.pascopa.com/parcel.aspx?parcel=2126240100000000810 7/18/2018 2018127552 Rcpt:1977661 Rec: 10.00 iDS: 0.00 IT: 0.00 �12117/30/2018 C. F. , Dpty Clerk PAULA S.0'NE1L,Ph.D.PASC0 CLERK & COMPTROLLER ' 27/30/2018 09:02am 1 of I OR BK 9764 PG 98 Permit No. Parcel ID No 24-26-21-0100-00000-0810 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in.accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 9. Description of Property: Legal'HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 81 Street Address: 3172 Kresterbrooke Lane Zephryhills FL 33541 2. General-Description of Improvement Single Family Residence Pool Screen Enclosure Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St.-Ste 200 Tampa FL. 33607 Address city State Interest in Property: Name of Fee Simple Titleholder:, N/A (if other than owner) Address city State 4.' Contractor: Lennar Homes, LLC Name W 4600 Cypress St, Ste 200 Tampa FL,33607' Address - city State Contractor's Telephone No.. 813.574.5700 5. surety: N/A Name, Address city State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address city State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes. LLC Name. 4600.W Cypress St, Ste 200 Tampa FL, Address city State Telephone Number of Designated Person: - 813.574.5700 8. In addition to himself,the owner designates /A Of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9: Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO-OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE.NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT: STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owners Authorized Officer/Director/Pariner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March _,by Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes, LLC ame of party on�a f �o ument was executed). Notary Siarl"'., atul Personally Known,R OR Produced Identification[:1 IS otary SlgZture Type of Identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in It are true to the best of my knowledge and belief. EL ISSAWHOURAN Signature of Nattral Person Signing Above UpIresJuns,111,2020 wpdatatbcslbcs form.. CITY OF / / / / BUILDING ZEPHYRHILLS fNOTICE DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT f 9,3 Ll�r4 10 THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. l ) 1 : It Is unlawful for any carpenter,Contractor.Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the installation. OFFICE HOURS 7:30AM-4:30 PM MON:FRI. INSPECTOR Jacqueline 5oges' From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday,August 8, 2018 1:11 PM To: Jacqueline Boges Subject: [Request received] 3172 kresterbrooke lane by#19983 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/232274 ..................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Aug 8, 10:10 AM MST full service 3172 kresterbrooke lane by#19983 water, sewer, water meter This email is a service from City of Zephyrhills Support . i 1 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: , 3172 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-0810 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19983 Date: /2018 ISSUED Byl BUILDIFOBOFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE