Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19984
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19984 `BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION- - -= LOCATION INFORMATION , - - Permit#:19984 Issued: 7/27/2018 Address: 3181 KRESTERBROOKE LANE. Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 378,391.35 Total Fees: 18,705.47 Subdivision: HIDDEN RIVER Amount Paid: 18,705.47 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-1200 CONTRACTOR INFORMATION - OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-363-2891 Work Desc: CONSTRUCT SINGLE FAMILY 3,359 SQ FT APPLICATION FEES BUILDING FEE 2,048.69 ELECTRICAL FEE 435.38 PLUMBING FEE 290.25 MECHANICAL FEE 203.18 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 71p] 'Inspections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. �A &-- C SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday,August 8, 2018 12:23 PM To: Jacqueline Boges Subject: [Request received] 3181 kresterbrooke lane by#19984 ##- Please'type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/232249 ....................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges i - Aug 8, 9:23 AM MST full service 3181 kresterbrooke Ian by#1 9984 , water, sewer, water meter This email is a service from City of Zephyrhills Support . I 1 ® kNAOfe Jet Stream Ultra Blowing 1A/o®I Insulation Attic and Cavity Wall Card rh ii7nle h 14Ve energy Batts and Blankets Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic boroing machine and a corrugated hose with a minimum W intemal comigatim,a minimum length recornmendatlons•Knauf insulation baits and blankets will of 150'.Coils in the hose should not be less than 36'In diameter Acceptable material feed tale is 5-35 ibs/minute.Recommended feed provide the full R-value. rate Is 15-25lbs/minute. R-Value* Minlmum'Thickness Thermal Performance(Sidewall and Attic Application) To obtain an The staled thermal resistance(R-value)is provided by Installing In accordance whin the manufacturer's instructions.Failure to Instal the _ Insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maudmum square feet of coverage per bag as recommended by the label (R•Vaiue)of. not be lees them: will result in lower installed R-values.Field blending of this product with other loose fill Insulations Is not recommended by the manufacturer. R-49 13.75' Cavity Wall Bag Net Weight-Nominal 32 tbs,,Minimum 31 lbs. R38HD 10.25" X' C 8 12.00' R-Value* Bags per 1000 SF Maximum Net Minimum 0HO 8•25' To obtain an The number of bags Coverage per Bag Weight per SF 0 10.Q0' cavity insulation par 1,000 square feet Contents of this The weight per square ty resistance of not etoa should net bag should not feel of installed Insulation 6 9.00' Framing Depth of; Densityhe less than: cover more than: should not be less than:. 6.50' Tx 4' 3.50' R-15 1.8 IbsJcu.ft. 16.4 bags 61.0 sq.ft 0.525 Ibs. 1 HO 5.50' 2'x 6' 5.50' R-23 1.8 IbsJcu.ft 25.8 bags 38.8 sq,it. 0.825 tbs. 6.25- HD 3.50' 2'x 8' 7.25' R-31 1.8 Ibs./cu.ft. 34.0 bags 29.4 sq.ft 1.088 tbs. 3.50' 2-x 10- 9.25' R-39 1.8 Ibs./cu.ft, 43.4 bags 23.1 sq.ft 1,388 tbs. 3.50' R means resinarce to teat flaw The Now coo Rive.the greater tin htsulaft poeec To gat tip mer4ed R-value,e b essential thal0ds YnWaoM be instAled pmpsdy 2.50' *ConformsMASTb1CWandredoral pen Attic Application Bag Net Weight-Nominal32 tbs.,Minimum 31 Ibs. F521F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness" To compensate for framing members;the number of bags per The number of bagsr contents of this The wefghVSF Thickness contents of this 1.000 sq ft.of area to be insulated should be as Shown below R-Value' 1,000 SF at not area bag should mot of lastatlad Installed Insulation bag should Bags/MSF Bags/MSF To obtain an insulation should not be loss corer Insulation should not should not be less not cover more resistance(R-Vsfuo)of: than: more than: be less than than: than: Joist 16'Framing O.C. 24"Framing O-C- R-60 29.7 33.6 SF .952tbs. 19,750' 19.750" JR-Value Dimensions Framing Framing 2x4 29.2 29.4 R-49 23.5 42.5 SF -753.ibs. 16.375' 15.375" R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 Ibs. 14.875" 14.875" 2x8 28.6 28.9 R-3B 17.8 56.2 SF .569 tbs. 13,000' 13,000' 2x4 23:0 23.2 R-30 13.6 73.3 SF .437 tbs. 10.375" 10.375' R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377Ibs. 9.125' 9,125' 2x8 20.4 20.6 R-22 9.8 102.2 SF .313Ibs, 7.750' 7.750' 2x4 20.4 20.8 R-44 2x6 20.1 20.3 R-19 8.4 119.3.SF .268 tbs. 6.750' 6.750' 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 Ibs. 4,750' 4.750' 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 tbs. 4100' 4.000' R-38 2x6 17.0 17.2 eay rat wean-+1mmr u In.rvinun s+� 2x8 16.7 17.0 cove.wendfwaasmam.�edemnteeama.we,a++erdEl�ymarn„annaapaznanla�voeeragzop aa ..niwararm,ymw�i�aa tienodescobs loft pdonuresregae,net;olAsmlC7eE.Tot EaoatanrosadFaWSpecfitmaie+4amm,Tice Aasse.R.-Am areoamm,whz®d&..Oaearorocsu. 2x4 13.2 13.3 RmesnresAucebawllbw Ther�neeRrasm aw�aaa ew haasaq poxr toys ma mated R,xlse.ans esssnea aw sit aasmnumtMmrrepay.ayau aooraesett,ptl hsauo- R-30 2x6 12.9 13.1 WisadlollmOmweW.kn 4onsdon'caoe*mmnpaoAa. 2x8 12.6 12.9 a'ivnedonT Faec scOng �ftp�zd �a p�"�belp* asanTrorreNoiseftgrewansybsgwcraTh@tO"an.waewndeasca 2x4 11.3 11A Vol.uaYpaanµsmaind*nvkofWwl- R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 2x6 .9.1 9.3 Attic Area R- at Inches 2x8 8.8 9,1 Sloped CeTngs R- at inches 2x4 7.9 8.1 Waits R- at Inches 2x8 7.4 7.7 R-19 2x6 7. 7. Floors(over an unheated crawl space) R- at Inches 2x4 5.3 5.4 Crawl Space Perimeter R- ai Inches R-13 2x6 5.0 5.2 Date Installed 2x8 4.8 5.0 Ellowff, s lation has been' in conformance with the above r 2x4 4.3 4,4 erp a detiogsJo nrovida an R-value of R- using � bags of this insulation to cove � O t1V square feet of area R-11 2x6 4.1 4.3 at a minimum thickness of_�Inches. W 18 4.1 IR Insulation Contractor fsgftwv n A A oassrsaiiun a.ir +ail . Company I U E.:-lo..n.0 GaEFrrue➢D Gad ud n LU u Fn..v..-a-W. m b.6-,d Jryb 1,- sw ih.d s...O oarnaaEwo Home BuOdor Innalure) c."ww.a.,r..a..",- Mv a:dr+q pvlsh a,y. rw e.s.'rMaw. uhJeen/W The coverage Information on this Attir/Sidewall card applies to the entire United States(including Minnesota). ` twriv krlaufinsuiation:us '''i ` f '' Knauf Insulation,Inc, One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825 4434 ext.8300 FAX (317)398-3675 � ©2015 Knauf Insulation,Inc. i IluiIdin„and n tnstru 011u l'tli(MCS) PASC .- COUNTY FI_oi,%16V Blower Door Test Report Form unn r: � Ptncertv Address: PUMA r: J Test rg eon Dar Y Name SKYETEC Test Date: I .20 Tesu,rise,11 ASSEN K H E L I F I Testereertr: MY3YG6 eurtanpt.-.904-903-1076 liklielifi@skyetec.com 402A.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower doer at a prrsstrrc of 02 inch, w-g.(50 Pascals).As required by the Building Official,testing stall be conducted by an approved third party.A written repo"of the results of the test shall be signed by the party conducting the test(including Agency Namc)and pro%ided to the Building Official prior to Certificate of Occupancy issuance.Testing shall be perfotmcd at any time after creation ofall scheduled penetrations of the building thermal envelope. During testing:(check to verify condition met) Exterior windows and doors,fireplace and stove dears shall be closed,but not sealed,beyond the intended weather- stripping or other I` Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond intended infiltration 1�J Interior doors,if installed at the time of the test,shall he open VV, ,P lExterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed 1 i �'1 sting and cooling systems,if installed at the time of the test,shall beturned off Supply and return registers,if installed at the time of the test,shall be fully open Vb Building volume(ft') = 24554. Q5o Airflow at 50 Pascal(CFM) _ +C ACHso Air changes per hour at 50 Pascal Q5ox 60=Vb= ACI1so(3.0ACHmhd...) Pass 'ail 0 El Outside Air mechanically introduced to space(less than 3.0 ACH) 1 hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance ttzth Section MZ4.1.2. Signature of TesTes ee Dale I _ N� \ � . 813-780-002 City of Zephyrhi|ls Permit Application pax-o 0-78n-00u1 Building Department ^ Date Received moxumxnm mxnPhone Contact for � Owner's Name Lermar Homes,LLC Owner Phone Number 00- 4600 FL 33607 Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number. Foe Simple Titleholder Address JOB ADDRESS LOT# [:1200 SUoo|mS|om Hidden River Phase One A pmnCEL|mu 124-26-21-0100-00000-1200 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED wowcomsm Aoo�JT [---1 SIGN �-1 �-� DEMOLISH . INSTALL [_1 REPAIR PROPOSED USE uFn F-� Comm F---� oTnsR TYPE oFCONSTRUCTION auocu �-� FRAME �---1 nTss� DESCRIPTION 0FWORK I Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE SopoOTAsE ns|Gxr 12 Story0 BUILDING. 11 VALUATION OF TOTAL CONSTRUCTION I � UELsCTRCAL FX-1 PROGRESS F-� NiR.E.C. �--' AMP SERVICE -��- --- OP0mB|No �� �� �MECHAN|CAL �VALU� ONOF MECHANICAL|NSTALU�|ON ��� =GAn nooFws F-1 SPECIALTY OTHERoT*ER FINISHED FLOOR ELsx4Tmwo 1 FLOOD ZONE AREA �-�vs� F--Lo ' DYES | � BUILDER SIGNATURE Address Liuonuo# � sLEcTmoV^m [�Lmonson ' SIGNATURE REGISTERED _-_---_. FEE CURREN 44deae 11034 Skipper Roadjampa, FL 3361 Uoenua# PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE o FEE CURREN ����-� Address Licanue# MECHANICALCOMPANY Layonet Plumbing, Heating &AC, Inc a|�m�nJ�� FEE -'_ L -y LN__j /dumso License# oT*sn COMPANY ammxnuRE Address 14211 Shoal Cffil Blvd,Spring Hill, FL 346 Licenua# xmuxnuxxmnxvmnnmnxxwnuuxnxwxxxmxxxxxomxxxnxxwuoumxxmxxoxnxmxoxmoxun RESIDENTIAL Attach pV Plot Plans;;g�sets of Building Plano;(1)metofsnorgyFonnu;R-}4VPonm8horDwwmnstmctinn. Minimum ten UN working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&1 dumpstar;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans,plus a Life Safety Page;(1)set m Energy Forms.m-0Aw Permit for new Minimum ten(1o)working days,after submittal date. Required bristle,Construction Plans,0onnwoter Plans vV Silt Fence' installed, Sanitary Facilities m1dvmputer.Site Work Permit for all new projects.All commercial requirements must meet compliance a|Gm PERMIT Attach;quem of Engineered Plans. ****pnOPsnTY SURVEY required for all NEW construction. Directions.-- | Fill out application completely. ovner&Contractor sign back mfapplication,notarized ` If over*uoou o Nnuun o,Commencement i6,oqu|red. (A/C upm,edou vver$zsom ^^ Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) nemofs if shingles amwam Service Upgrades A/C Femmo(Pkot/Gunmy/Footago) Driveways-Not over Counter ifon public madmmyu'needuROW � PASCO COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name Control County Parcel No. �{— Zl-0(�0(—��`��(�0- �ZD� SubDiv: Ct7dd erx wise r Address/Location Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined t_ Impact Fee Amount $. 3,(32— Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (1cJ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total $, Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amounfer RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION z. PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of,a copy of this forrn,placing the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0100-00000-1200 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 24-26-21-0100-00000-1200 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $28,639 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3181 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 ,lust Value $28,639 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,639 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 120 Taxable Value $28,639 OR 9750 PG 2604 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _ — Use _ __Description,Zoning— Units Type— Price ICondition�Value 1 _0100 — SFR MPUD 1 6,000.00 I SF_- $4.50 1.00— $2� 7,000 2 _ 0100 SFR MPUD 1,821.00 SF $0.90 I 1.00 $1,639 Additional Land Information Acres 1 0.18 lTax Area 30ZH TCode j Residential Code I HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line _—` _ Description —'Year 1Units ;Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year_ Book_/Page _ IType—�— -- _il!3 R Cod_e_ Tondition Amount 06/2018 _ 9750 / 2604 _' Warranty Deed 05 _ ( lti- — I— Vacant Multi-Parcel Sale 09/2011 _ 8606 / 3376 j Warranty Deed �_ 05 __� Vacant _ Multi-Parcel Sale 06/2010 8360 / 1872 !� Certificate of Title 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000001200 7/18/2018 Lennar Homes-3181 Kresterbrooke Lane-3,359 sq ft o umn ts SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 378,391.35 FEE SHEET $ 1,935.00 ADDRESS $ 30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 2,048.70 ELECTRICAL: $ 435.38 PLUMBING: $ 290.25 MECHANICAL: $ 203.18 SUB-TOTAL $ 2,977.50 TOTAL $ 2,977.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 7,104.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,705.47 Lennar Homes-3181 Kresterbrooke Lane 3,359 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 378,391.35 FEE SHEET $ 1,760.00, ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,847.13 PARK IMPACT FEES $ 769.56 I SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,447.97 'Single Family. we In . Pl - an Review Comments 1: T.F.I. shall be a minimum:of.8" above.the road elevation and an engineered site plan. 2.. Lots shall be graded to comply with R401.3 of the F.B:C: 3. _Compaction test required.if 24" or more:of fill dirt is brought in-at any one'place: .'.: 4:. :Tie in-survey required-before pouring concrete. 5. Driveways require a R:O.W. use permit. All sides of driveway thru the sidewalk shall have ex ansion material:- p 6.. All, setbacks.shall be met.:. . - 7. All property_markers shall be uncovered and marked'at time of first inspection: - 8: All A.D.A. requirements shall be met. . .9.. No:electric, plumbing,mechanical;.or fraining shall be covered without an:inspection and approval first. 10. All Garages shall:comply;with:section-R302:6:of the:F.B:C:(Fire Separation). I L:Appliances:shall not:be installed in:a location where subject to mechanical damage unless. p.rotected'b a roved barriers. M303.4 of.the F.B.0 . . y pp 12. Water heaters shall corriply.with section.P607,3 of the F.B.C. 13. Foundation supports for A/C units.shall be raised at feast 3' above fiiushed grade,. M1308.1. , . . . 14. Return air in all:bedrooms..F.B.C. .M1620.4. 15: Soke detectors are to be installed:in accordance:wit m R313 .1 of-the-F.B.C. 16.: All glazing requirements are:.to be in accordance with R308.4 of the F.B:C. 17. All means-of egress are to be in accordance with R311:of the F:B.C. - 18. `.`Green gypsum board" shall riot be used as.a backer in showers or tubs. R702.4.2.F.B.C: 19._Combination-type AFCI breakers.are,required;at all locations requiring an AFCI.type breaker: 20. Carbon-monoxide.alarms will.be required in new construction that uses fossil-burning heating gar g Y . .. or a fiances or an attached ara e: The . shall be.installed in accordance with the F.B.C. . pp- 21. A1,1 plumbing;mechanical,:and electrical shaRbe-separate from unit.to:unit: This includes all underground plumbing and electric: 22. All 2016:N.E.C. Codes'will'be enforced.. 23:Tamper-Resistant Receptacles in accordance with 4Q6.11. of the 2016 N.E:C .24: In accordance.with.the Land.Development:Code; lots shall be sodded before final-of least 10 - feet around the structure... . . 25. Blower door test and blown in insulation-card shall-Ue provided before C:O: ai "26.A--copy of-the ener"cacts.shall be with permit at all tunes. 27 Copy of fnal insulation report shall beprovided witlt permitbefore:final F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6ffi Edition R.O.W.-Right of Way A.D.A:-Americans with Disabilities Act N.E.C.-National Electric Code(2011) FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3181 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: y� Owner: Lennar Homes Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (2313.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2173.00 ft2 6. Conditioned floor area above grade(ft2) 2902 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 18.0 SEER:15.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 86.03 PASS Total Baseline Loads: 85.93 hereby certify that the plans and specifications covered by Review of the plans and TEST this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance + with the Florida Energy Code. PREPARED BY: 'Dave �Wl ich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. .� with the Florida Energy Code. CO5. MAY 0 3 2010 OWNER/AGENT: BUILDING OFF CI DATE: I DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/1/2018 1:19 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3181 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes .jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior , R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2313.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2173.00 ft2 6. Conditioned floor area above grade(ft2) 2902 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 18.0 SEER:15.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features EF:0.950 b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 86.03 Glass/Floor Area: 0.067 PASS Total Baseline Loads: 85.93 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: '�ayeGaI�tGGt Before construction is completed i� DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. MAY 0 3 2018 OWNER/AGENT: BUILDING OFFICIA DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 1:19 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 I i I I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3181 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (2313.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2173.00 ft2 6. Conditioned floor area above grade(ft2) 2902 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R=' ft2 11.Ducts R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor: Dbl, U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 b.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features EF:0.950 b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 86.03 PASS Total Baseline Loads: 85.93 S I hereby certify that the plans and specifications covered by Review of the plans and � this calculation are in compliance with the Florida Energy specifications covered by this: '�__.; p "., i Code. calculation indicates compliance Dave GaI�GGt with the Florida Energy Code. rrrrr ,, ti, PREPARED BY: Before construction is completed :r f DATE: this buildingwill be inspected for compliance with Section 553.908 *, =. •�= I hereby certify that this building,as designed, is in compliance Florida Statutes. With the Florida Energy Code. 'OXj MAY 0 3 2018 OWNER/AGENT: BUILDING OFFICIAL. DATE: DATE: VW - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/1/2018 1:19 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 I i i FORM R405-2017 PROJECT Title: 2889B1 sf ADS Carrier Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2902 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1793 15419.8 2 Block2 1109 8872 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1793 15419.8 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1109 8872 No 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1 st Floor 137 ft 0 1793 ft2 -_ 0.3 0 0.7 2 Floor over Garage 2nd Floor _r °e 437 ft2' 11 0.15 0 0.85 3 Floor Over Other Space 2nd Floor ---- W_ 672 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2425 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2239 ft2 N N 5/1/2018 1:19 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING F # Ceiling Type Space R-Value Ins Type Area Framing Frac ;Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1109 ft2 0.11 Wood 2 Under Attic(Vented) 1 st Floor 30 Blown 1064 ft2 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 30 Batt 140 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 58 8 8 502.7 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 _ 5 N=>NE Garage Frame-Wood 1st Floor 11 19 9 8 8 171.2 ft2 0 0.01 0 6 W=>NW Garage Frame-Wood 1st Floor 11 18 6 8 8 160.3 ft2 0 0.01 0 7 N=>NE Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>SE Exterior Frame-Wood 2nd Floor 11 29 6 8 236.0 ft2 0 0.600000 0 9 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 10 W=>NW Exterior Frame-Wood 2nd Floor 11 29 9 8 238.0 ft2 0 0 0.600000 0 11 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ft2 2 W=>NW Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 13 ft 4 in None None 2 E=>SE 2 Metal Low-E Double Yet, 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 48.0 ft2 1 ft 0 in 0 ft 10 in None None 4 S=>SW 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in None None 5 N=>NE 7 Metal Law-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 0 ft 4 in None None 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 4 in None None i 7 W=>NW 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 4 in None None 8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 3 ft 5 in Drapesiblinds None i 5/1/2018 1:19 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437 ft2 437 ft2 44 ft 8.6 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000319 2429.2 133.36 250.8 .2947 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 2 Electric Heat Pump/ None HSPF:8.5 17.7 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 358.6 ft 1st Floor 89.6 ft2 Proposed Qn 1st Floor —cfm 53.8 cfm 0.03 0.60 1 1 2' Attic 6 221 ft2 2nd Floor 55 ft2 Proposed Qn 2nd Floor —cfm 33.3 cfm 0.03 0.60 2 2 I 5/1/2018 1:19 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 . I I FORM R405-2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar ]A r [ ]Ma [X]Jun X Jul [X]Au Se Oct Nov Dec Heatin Jan Feb Xj Mar ]APr [ ]MaY [ ]Jun 4 Jul [ ]Aug �Xj SeP Oct Nov Dec Ventin Jan Feb X Mar [X]A r [ ]Ma [ ]Jun [ Jul [ ]Au Se Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I � I , I I i I 5/1/2018 1:19 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 I FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types In Area a.Under Attic 5. Is this a worst case? Yes (Vented) R=30.0 2173.00 ft2 6. Conditioned floor area(ft2) 2902 b.Knee Wall(Vented) R=30.0 140.00 ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.54 96.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 358.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 b. U-Factor: Dbl,U=0.56 64.00 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr ' Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 b.Central Unit 18.0 SEER:15.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.172 ft. b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average SHGC: 0.302 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2EF:0.95 b.Floor Over Other Space R=0.0 672.00 ft2 b. Conservation features c.other(see details) R= 437.00 ft2 None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) aSxATA in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: 05/02/18 Address of New Home: 3181 Kp sterbrooke Lane City/FL Zip:ZeFhyrhills,FL 33540 'C-;': 5 *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 1:20 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 i Building Analysis Job: 2889B1sf ADS Carrier g Y Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 17 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 53.6 Dry bulb (°F) 31 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(7) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.5 6957 30.1 gas Glazing 30.2 3426 14.8 wall nfiltration Doors 21.2 419 1.8 Ceilings 1.3 1443 6.2 Floors 3.3 5951 25.8 Infiltration 2.1 2877 12.5 Ducts 2020 8.7 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Other Adjustments 0 Ceilings Total 1 23093 100.0 • • M, • Component Btuh/ft2 Btuh % of load Walls 2.9 3724 20.0 Internal Gains Glazing 54.3 6167 33.2 Walls Doors 17.2 340 1.8 Ceilings 1.8 2013 10.8 Floors 0 0 0 Infiltration 0.5 684 3.7 Ducts Ducts 2360 12.7 Ventilation 0 0 Internal gains 3290 17.7 Infiltration Blower 0 0 Glazing Adjustments 0 Ceilings Total 18578 100.0 other Latent Cooling Load=2305 Btuh Overall U-value= 0.107 Btuh/ft2-°F I Data entries checked. I -�- wrightsoft� 2018-May-01 13:37:13 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ent\2889B1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E I Building Analysis Job: 2889B1sf ADS Carrier g Y Date: 5l1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 17 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 53.6 Dry bulb(°F) 31 92 Infiltration: Daily range ff) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 3.8 3623 32.9 Ducts Glazing 30.2 2386 21.7 Doors 0 0 0 Wan Ceilings 1.3 1391 12.6 nfiltration Floors 2.0 30 0.3 Infiltration 2.1 2121 19.3 Ducts 1448 13.2 Piping 0 0 other Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 11001 100.0 Compohent Btuh/ftz Btuh % of load Walls 2.9 2718 21.2 Internal Gains Glazing 52.2 4127 32.3 walls Doors 0 0 0 Ceilings 1.7 1883 14.7 Floors 0.9 14 0.1 Ducts Infiltration 0.5 504 3.9 Ducts 1730 13.5 Ventilation 0 0 Infiltration Internal gains 1820 14.2 other Blower 0 0 Glazing Adjustments 0 Ceilings Total 12796 100.0 Latent Cooling Load=2056 Btuh Overall U-value= 0.088 Btuh/ftZ-°F Data entries checked. 41- wrightsoft- 2018-May-01 13:37:13 •k w -��^P� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..ent\2889M sf ADS template 1.5-2ton Carrierrup Calc=MJ8 Front Door faces: E r ' Project Summary Job: 2889B1 sf ADS Carrier Date: 511/2018 lower floor By: Dave : BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Notes: FBC 2017 Design In • • Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 17 OF Daily range L. Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21073 Btuh Structure 16218 Btuh Ducts 2020 Btuh Ducts 2360 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23093 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18578 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1902 Btuh Ducts 403 Btuh Central vent(0 cfm) 0 Btuh Heating Coolin (none) Area(ft2) 179E 1793 Equipment latent load 2305 Btuh Volume(ft') 15976 15976 Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 20882 Btuh Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9.154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400: Btuh Heating output 24000 Btuh @ 47'F Latent cooling 3600. Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 32 OF Backup: Input= 6 kW, Output=22126 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri0U1tsoft- 2018-May-01 13:37:13 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 14C*Ck ...ent\288981 sf ADS template 1.5-2ton Carrierrup Calc=MJ8 Front Door faces: E Project Summary Job: 2889B1 sf ADS Carrier 1 Date: 5/1/268 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: FBC 2017 Desicin Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9552 Btuh Structure 11066 Btuh Ducts 1448 Btuh Ducts 1730 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 11001 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12796 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1760 Btuh Ducts 297 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cooling (none) Area(ft') 1109 1109 Equipment latent load 2056 Btuh Volume(ft') 8872 8872 Air changes/hour 0.33 i 0.18 i Equipment Total Load (Sen+Lat) 14852 Btuh Equiv.AVF (cfm) 49 26 Req. total capacity at 0.85 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC518AO0300 Cond 25HBC518AO0300 AHRI ref 9154643 Coil FB4CNP025L AHRI ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300. Btuh Heating output 17700 Btuh @ 47'F Latent cooling 2700 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point=20 OF Backup: Input= 3 kW, Output= 10697 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -�- wrightsof[® 2018-May-01 13:37:13 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..ent\288981 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 2889B1sf ADS Carrier Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.4°F Sensible gain: 18578 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.4°F Latent gain: 2305 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 20882 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 110% of load Latent capacity: 3600 Btuh 156% of load Total capacity: 24000 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 23093 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F I Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier ' Model: 25HBC524A00300+FB4CNP025L Actual airflow:,., 800 cfm Output capacity: 18304 Btuh 79% of load Capacity balance: 32 OF Supplemental heat required: 4789 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 6.5 kW 96% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. 1 Wrightsoft® 2018-May-0113:37:13 .rrt•�a- pw��, � Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ent\2889B1 sf ADS template 1.5-2ton Carrierrup Calc=MJ8 Front Door faces: E i Manual S Compliance Report Job: 2889B1sf ADS Carrier Date: 5/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.4°F Sensible gain: 12796 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.4°F Latent gain: 2056 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 14852 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 120% of load Latent capacity: 2700 Btuh 131% of load Total capacity: 18000 Btuh 121% of load SHR: 85% i Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 11001 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F I ' Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 13453 Btuh 122% of load Capacity balance: 20 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F ' I Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 3.1 kW 97% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 1 wrig17tso t® 2018-May-01 13:37:13 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ...ent\2889B1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26-S, RNG. 21 E. PLOT PLAN BEARING BASIS: LOT 120 HIDDEN RIVER PHASE ONE 8 NORTH BOUNDARY OF SUBJECT PLAT BEINGS 89*40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT,TO ANY FACTS THAT{ MAY BE DISCLOSED BY A FULL AND ACCURATE N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT = ON LOT AREA CALCULATIONS EASEMENTS AND RESTRICTIONS OF RECORD. _M7_SQ. FT. LIVING AREA =__=L__sQ- FT. o UNDERGROUND FOOTER, STEM WALL, AND ENTRY = 1-1—SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR GARAGE = !LQL—SQ. FT. II SHOWN. COVERED LANAI = NZA—SQ. FT. PATIO FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE FT. NOTES TAKE PREFERENCE. A/C & CONC PAD =_llL__SQ. FT. 6 PRIVATE SIDEWALK FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND to IMPERVIOUS PAGE INDICATES THAT PLAT IS IN += 2JqjEL_SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO SOD = 5215 SQ. FT. CHANGE AND/OR REVISION. CERTAIN DATA SHOWN HEREON BASED ON OFF LOT AREA CALCULATIONS RIGHT OF WAY =__R99_1 ESQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON =__L4,L__SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD FT. TO PROPERTY LINE. PRELIMINARY DRAWING: TOTALS THIS PLAN IS FOR PERMITTING PURPOSES AREA =__8819L85_SQ. FT. ONLY, NOT FOR CONSTRUCTION. VERIFY DRIVEWAY =__:44.0___SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SIDEWALK =__A(Lt__SQ. FT. SOD =__.5Z_7P__SQ. FT. LEGEND: NOTES: _.—= PROPOSED DRAINAGE FLOW LOT GRADING TYPE = A (00.00) = PROPOSED GRADE PROPOSED PAD ELEVATION m N/A E-00.00 = EXISTING GRADE FRONT SETBACK = 20' Lij LOT 121 = 10' DRAINAGE/UTILITY EASEMENT SIDE SETBACK = 10' PLAT REAR SETBACK = 10' BOUNDA Y LOT 104 HIDDEN RIVER PHASE ONE A 0 (PLAT BOOK 74, PAGES 101-121) z 0 r> In C� C14 C, S 89'36'58" E 110.00' C) a- ......................... '36'58. wi PRM(P)-,/ 33.64'� Cl N sysrw W ....... 4......- 25.00' (TYP) ¢ 56'-6- 20.50' LOT 105 Ld 5 00 U , HIDDEN RIVER PHASE ONE A LOT 120 a.0 a,F0 20.SV - (PLAT BOOK 74, PAGES 101-121) 00 Wain a- < A 0 XR ..... 33-49- a I 0 V- 0 0 U 6 Ns Tgr4l47 ...... N 8V58'06-W .......... col Q:,Lu_ Uj9U .0Z N ' 9 1712"78. 110.00, .. ......... PLAT 25-00. ...... BOUNDARY LOT 119 4 PROPOSED: DESCRIPTION: LOWEST FLOOR ELEVATIONS: LOT 120, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", LIVING AREA: 72.50' AS RECORDED IN PLAT BOOK __ PAGES --- THROUGH GARAGE AREA: N/A OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS :REFERENCED TO! NATIONAL GEODETIC VERTICAL CURVE RADIUS I ARC CHORD I BEARING I DELTA DATUM OF 1929. MEAN SEA! 350.00' 69.82' 69.70- S 06'05-55- W 11-25-45-1 1 C53 240.00' 1 47.87' 1 47,80' N 06-05-55- E 11-25'45" LEVEL- 00.00 FT. APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 LEGEND : = CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, rk= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM*T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&O= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drown By: Sms Square Feet: 7820.67 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: t 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30- ( ./���� NOT VALID WITHOUT THE SIGNATURE AND jDate of Survey; o4-tzokdl� THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/19/2018 RTM 160N R. BEACH DATE LICENSED SURVEYOR AND MAPPER FLORID -ZEG. LAND SURVEYOR No. 2984 J LB#4493 Revisions: --------- Air Fr-a. Ff E�i, i 74.00 ...... 30 74M P ©i A D I-1A-W'aEY r22 sQL SS >i ., , 1 Z111.00 0:0.;.601A31 1—r\7pr—Ppzs sfw a!1Q.4f1 1A 1L1S ow I .111222564 I a FF EL . FF 3lall "E1. 102 . 13 1 ; .. .. — I FF . , A1 I AAIAI MA E A FrL AA II D EI I F7 F1."MW- 0wLFMuFA Mi1 Ell7 9 -1 0MP I47F.— 27oAAFAA A-FW: AAA-E.AAS L8,KL 1i I 0 i, 3a r F ,A 1 121 7 FW3 106 rEL ," 10 , We W 11lrrVD HE andAodates', Im. 3SIGHM SfSp HiuENRIVER SUB[ -HQRN ANG ASSOCIATES, INC. or%Khtq By EPIAYRKiLLr, FLORIDA 33- 42 -0400 FALX (S13) 782-497E HORMCOM CA GCOM1526 CITY OF ZE-PHYPHILLS - � I illlll{il{I INII Iiiil Iilil Iilli ilili{Iili iliii hill Illi 101i� � 2018227556 -Acpt:1977661 Rec: 10.00 'DS: 0.00 IT: 0.00 ,07/30/2018 C. F. , Dpty Clerk 41AULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER 07/30/20 18 09:02am I- of I OR 1BK 9764 PG 102 Permit No. Parcel ID No 24-26-21-0100-00000-1200 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives.notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided In this Notice Of Commencement: 1 Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 120 street Address: 3181 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of-improvement Single Family Residence i Pool I Screen Enclosure Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St, Ste 200 Tampa FL. 336071 Address city State Interest in Property: Name of Fee Simple Titleholder: ' N/A (If other than owner) Address city .State 4. Contractor: _Lennar Homes, LLC Name 4600 W Cypress St, St .200 Tampa FL,33607 Address city State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address city State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address city State Lender's Telephone No.: 7. Persons within the State of.Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address city State Telephone Number of Designated Person: '813'574.5700 8. In addition to himself,the owner designates N/A Of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST-INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLASCif Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March _,by Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes, LLC (name of party o 1 m instrument was executed). Personally Known R OR Produced Identification 0 Not Signature Type of Identification Produced Name(Print) lissa Holleran Verification,pursuant to.Section 92.625 Florida Statutes: Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in � r it are true to the best•of my knowledge.itrid belief. ELISSAM.HOLLERAN Signature of Natural Person Signing Above COMM1181on wpdata/bcs/bcs form, 'UnOid7briTmy.Fafnjmuronoo"o4m7o10