Loading...
HomeMy WebLinkAbout18-19985 CITY OF ZEPHYRHILLS 5335-8TH STREET 41 (813)780-0020 19985 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION -_ - - =LOCATION INFORMATION =- Permit#:19985 Issued: 7/27/2018 Address: 3184 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 378,391.35 Total Fees: 18,705.47 Subdivision: HIDDEN RIVER Amount Paid: 18,705.47 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-0820 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-363-2891 Work Desc: CONSTRUCT SINGLE FAMILY 3,359 SQ FT APPLICATION FEES - BUILDING FEE 2,048.69 ELECTRICAL FEE 435.38 PLUMBING FEE 290.25 MECHANICAL FEE 203.18 SEWER CONNECTION RESIDEW 2,090.00 WATER METER RES 3/4" 473.78 WATER CONNECTION RESIDENT 1,010.00 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections Required FO TER 2ND ROUGH PLUMB Misc I SULATION CE L G FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental, entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney, before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. I I CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER L.ennar Homes-3184 Kresterbrooke Lane-3;3'S9 sq,ft, SQ.'FEET PRICE: MAIN.OR LIVING: 3,359 $ 112.65 15174720082 OTHER AREA UNDER'ROOF: $ 88:00 OTHER: VALUATION $ !378,391:35- FEE- .SHEET $ 1;935.M ADDRESS ,$ 30.00. DRIVEWAY $. 45'00, BUILDING: $ 2,048,7.0, ELECTRICAL: $' 43538, PLUMBING: $, 29025: MECHANICAL: $ 203:18- SU137TOTAL ,$ 2,977:50. TOTAL SEWER: .$ 2`090;00. WATER: I- 1;,01Q.OQ V IRRIGATION' $' TOTAL: $ 3000.00 WATER METER: $ 473.78, IRRIGATION;METER $ - FIRE-DEPARTMENT FEES' PLANS TOTAL: nla INSPECTION TOTAL: PERMIT TOTAL TOTAL: :$ - PUBLIC SAPETY IMPACT.FEES POLICE $ 254.00 FIRE -$° 213.00 5% $: 26.35 TOTAL: $: 553:35- SU&TOTAL 7,104.63 i PARK IMPACT FEES .$ 7769:56 it SIM: $: T.,128.00 Ion% $: 7028.00 1.0016 ,.$ 71.28 TOTAL: 1, 7,199.28 i T„I.F'S: $ 3,632-.00 '99% '$ 3;595.68 1% .$ 36.32 f TOTAL: 1.'8,705.47 i f 813-780-00201 City of Zephyrhills Permit Application - Fax-813-780-0021 Building Department Date Received MAY Q 3 ZQ1� Phone Contact for Permittin 813 363 _ 2891 Owner's Name Lennar Homes,LLC Owner Phone Number 811. 74.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3184 Kresterbrooke Lane LOT# 0820 SUBDIVISION Hidden River'Phase One A PARCEL ID# 24-26-21-0100-00000-0820 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED Ii./ Ii NEW CONSTR 8 ADD/ALT SIGN Q DEMOLISH INSTALL REPAIR PROPOSED USE s v u SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL Q I DESCRIPTION OF WORK Single Family Residence I pool/Screen Enclosure I Fence BUILDING SIZE U/R IF 3359 —] SQ FOOTAGE 2902 HEIGHT 2 Story .'.O BUILDING $ f t o VALUATION OF TOTAL CONSTRUCTION lLI ELECTRICAL L AMP SERVICE($ ® PROGRESS ENERGY Q W.R.E.C. ' PLUMBING 1$ � MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING 0 SPECIALTY I, OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES D . ■ Y ■ . . . . . . . . . . . . . . . . . . . . . . .- ._. ._. . ` • i BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 4600 W.Cypress St,Ste.200,Tampa,FL 33607 License# FCGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N J FEE CURREN Address 1034 Skipper Road,Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y I N FL 34674-5308 CFC042998 Address P.O. Box 530 , Bayonet, License# MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE V REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License# CAC058062 OTHER COMPANY - SIGNATURE. REGISTERED Y/ N FEE CURREN- Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# 1 CCC057991 1 -ti [ i [ lt [ t [ liltlil '11 [ Ilitlillil11111 [ / 11 ! [ iI111 [ ltlI1I1CIIt1 [ ttltltt ' RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required,onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/iarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety'Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days,after submittal date. Required onsite,Construction Plans;Stormwater Plans,w/.Silt Fence installed, .Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . • Y .. . . . . ■ . . . . . . ■ ■ ■ ■. ■ 1 ■.�-L■ • Y ■ ■ ■ 1 Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2600,a Notice of Commencement Is required. (A/C upgrades over$7600) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER.PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Jacqueline Boges From: City of Zephyrhills Support<support@zephyFhillsfl.zendesk.com> Sent: Wednesday,August 8, 2018 2:31 PM To: Jacqueline Boges - Subject: [Request received] 3184 Kresterbrooke Lane by#19985 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/232322 ..................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Aug 8, 1 1 :30 AM MST full service 3184 kresterbrooke lane by#19985 water, sewer water meter This email is a service from City of Zephyrhills Support . 1 Lennar Homes-3184 Kresterbrooke Lane-3,359 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 378,391.35 FEE SHEET $ 1,935.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 2,048.70 ELECTRICAL: $ 435.38 PLUMBING: $ 290.25 MECHANICAL: $ 203.18 SUB-TOTAL $ 2,977.50 TOTAL $ 2,977.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 7,104.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,705.47 Lennar Homes-3184 Kresterbrooke Lane 3,359 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 378,391.35 FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - I PUBLIC SAFETY IMPACT FEES POLICE $ 254.00. FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,847.13 PARK IMPACT FEES $ 769.56 I SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,447.97 PASCO COUNTY, FLORIDA Permit No. -I !vS Date Permitted Builder Name/Owner Name 4 cControl#' County Parcel No. Vf—26 Z 0(60-&OD&1.)6 SubDiv: P� Address/Location ClassiticationfType of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: V Exempt ❑ Yes ❑ No How Determined Ev;_ Impact Fee Amount $34. Zone No. TAZ: C;e SCHOOL IMPACT FEE p Account (056) Single-Family petached House Amount $ 7� t�G ze) (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [�] Yes Q No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total . Zone TOTAL AMOUNT $ 762-66 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total / Exempt ❑ Yes ❑ No How Determined Total Am6W� RESOURCE FEE ERU TOTAL AMOUNT Prepared By r Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY • Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner.on notice of this assessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0100-00000-0820 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 24-26-21-0100-00000-0820 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,939 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3184 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $27,939 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,939 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 82 Taxable Value $27,939 OR 9750 PG 2604 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _—{Use _ Descriptions oning Units____Type _Price Condition I e _ 1 f �0100 SFRR MPUD 6, - _ J t_ _000.00 SF 4 50 1.00 � $27,000 � - SF 1.00— f $9392 0100 SFR MPUD 1,043.00 $0.90 Additional Land Information �� I FEMA I _—�------ -------- Acres 0.16 Tax Areal 30ZH Code -- Residential Code HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ _ _Extra Features (Card: 001 of 001) Line_ _ _____ Description ,_ _Year _ lUnits iValue V No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page T _I---Type DOR Code Condition ].Amount _ 06/2018— 9750 / 2604 _ Warranty Deed 1 05 _1 Vacant_ Multi-Parcel Sale 09/2011 8606 / 3376-__-) Warranty Deed �— 05 A Vacant j Multi-Parcel Sale 06/2010 r 8360 / 1872 i Certificate of Title 12 I Vacant j $0 i http://search.pascopa.com/parcel.aspx?parcel=2126240100000000820 7/18/2018 Single. Family Dwelling - Plan Review Comments: I.: F.F.E. shall be a minimum:of 8".above.the road-elevation:and'an engineered site plan. 2.. Lots shall be graded.to.comply with R401.3 of the F.B:.C: 3. _Compaction:tesirequired.if24" or more:of fill dirt is brought in:at any one place: 4.. :Tie in' survey required before pouring concrete.. 5.: -Driveways:require a R:Q:W. use permit:: All sides of.driveway.thru the sidewalk shall''have. expansion material: -. : . : '6.. All setbacks-shall be met. 7.: All property:markers shall be uncovered and marked.at time of first inspection: 8:. :All A.D.A.requirements shall be met._ 9. No electric;plumbing,mechanical;.or Trai ming shall be.covered without an:inspection and approval first. . 10._All:Garages shall_comply_.with:section R302:6:of the:F.B:C: (Fire Separation). I L'Appliances shall-not:be installed in:a location where subject to.mechanical dam.age'urAess- protected by approved barriers. M303.4-of the F.B.0 12. Water heaters shall comply with section:P607.3 of the F.R.C. 13.Foundation supports for.A/C.units shall be raised at least 37, above finished grade. M13'08.1. 14. Return'air in-all-:bedrooins. F.B.C. M1620.4 15: Smoke detectors are to be installed:in accordance.with,R313:1 of the F.B.C. 16::A11 glazing requirements are:.to be in accordance with R308.4,of the ERE. 17.. All means,of egress are to be in:accordance with R311of the F:B.C. :: . 18. `-`Green gypsum.board shalt not be used.*s.a backer_iri showers or tubs. R702.4:2.F.B.C. 19._Combination-typeAFCI-breakers are.required:at all.locations requiring anAFCI.type breaker: 20: Carbon monoxide.alarm' s will.be required in:new:construction that uses fossil-burning:heating or appliances or an attached garage:. They shall be.installed in accordance with.the F.H.C.. 21. All plumbing, mechanical,:and electrical shall be separate from unit,to:unit: This includes all underground plumbing and electric: 22_-.All 2016 N.E:C:. Codes'Will'be enforced. 23.Tainper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C 24:In aecordance..with the Land:.Development:Code;dots.shall be.sodded before final of least 10. feet around.the structure. .. 25. Blower door:test and blown in insulation card shall be provided before C.D. 26 A copy:of the energy cacls.shall be with hermit at alt times.. 27 -Copy of final insulation report'shall be,:Provided:fvith mr1lat before 414 F.F.E.-Finished Floor Elevation F:B.C- Florida Building Code 6 'Edition= R.O.W.-Right of Way A:D.A.-Americans with Disabilities Act N.E:C.-National Electric Code(2011.) FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889AI sf ADS Carrier Builder Name: Lennar Homes Street: 3184 Kresterbrooke Lane Permit office: Q�o#ZeXhyrhj11s City,State,Zip: FL, Permit Number. I - Owner. Lennar Homes Jurisdiction:611 00 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R--1 1.0 1114.00 ft2 3. Number of units,if multiple family I c.Frame-Wood,Adjacent R=1 1.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R-- ft2 10.Ceiling Types,(2307.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area above grade(W) 2896 b.'Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(l 93.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor. Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U=Factoc Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 b.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U,=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) - R= 437.00 ft2 15.Credits Pstat Glass/Floor'Area: 0.067 Total Proposed Modified Loads: 85.94 PASS Total Baseline Loads: 85.84 I hereby certify that the plans and.,specifications covered by. Review of the plans and this calculation are in compliance with the Florida Energy. specifications covered by this 0 :z Code. calculation indicates compliance 1z With the Florida Energy Code. PREPARED BY: Dave Aull�h Before construction is completed N'. DATE: this building will be inspected for 01i -A - compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. MAY 0 3 2018 OWNER/AGENT:- BUILDIN FFICI E L: 3, ig DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as •certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETIICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 1:11 PM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 F , FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889A1 sf ADS Carrier Builder Name: Lennar Homes , Street: 3184 Kresterbrooke Lane Permit office: City of ZephyrhillS City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ftz b.Frame-Wood,Exterior R=11.0 1114.00 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ftz 4. Number of Bedrooms 5 d•N/A R= ftz 10.Ceiling Types (2307.0 sgft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2167.00 ftZ 6. Conditioned floor area above grade(ftz) 2896 b.Knee Wall(Vented) R=30.0 140.00 ftZ Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 11.Ducts R ftz 7. Windows(193.3 sgft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U=Factor: Dbl,U=0.56 64.00 ftz 12•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 c. U-Factor. Dbl,U=0.56 33.33 ftz b.Central Unit 18.0 SEER:15.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ftz a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sg a.Electric Cap:40 gallonsft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ftz b. Conservation features b.Floor Over Other Space R=0.0 672.00 ftz None c.other(see details) - R= 437.00 ftz 15.Credits Pstat Total Proposed Modified Loads: 85.94 w C Glass/Floor'Area: 0.067 PASS Total Baseline Loads: 85.84 i I hereby certify that the plans and specifications covered by Review of the plans and Q -TIiE S ,q , this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ,�i,�'' -' �a�eGaf�r`c!� with the Florida Energy Code. !•+ rar,� �� ?,�,�?``„ p PREPARED BY: Before construction is completed - DATE: this building will be inspected for __j?)�_ - compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. , with the Florida Energy Code. G'p OWNER/AGENT: MAY O 3 2018 BUILDING O.EFICI : DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires aw envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 1:11 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 , 5 ' FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3184 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A - R= ft2 10.Ceiling Types (2307.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area above grade(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH: 1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 b.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17�7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 85.94 PASS C Glass/Floor Area: 0.067 ASS Total Baseline Loads: 85.84 I hereby certify that the plans and specifications covered by Review of the plans and this;calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ' Dave �G� with the Florida Energy Code. D �+ rem..%r. -., •;;�• x,'f) PREPARED BY: A Before construction is completed DATE: this buildingwill be inspected for P t7 _r 0; compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'Ojj MAY 0 3 2018 OWNER/AGENT: BUILDING OFF CIA[ ' i DATE: DATE: 511 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page.1 of 5 FORM R405-2017 PROJECT Title: 2889A1 sf ADS Carrier Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2896 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1793 15419.8 2 Block2 1103 8824 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1793 15419.8 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1103 8824 No 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 137 ft 0 1793 ft2 _-- 0.3 0 0.7 2 Floor over Garage 2nd Floor ---- 437 ft2 11 0.15 0 0.85 3 Floor Over Other Space 2nd Floor ---- ---- 672 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2419 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2233 ft2 N N I 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1103 ft2 0.11 Wood 2 Under Attic(Vented) 1st Floor 30 Blown 1064 ft' 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 30 Batt 140 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below A Ornt To IA/:;Il Type1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 58 8 8 502.7 ft2 0 0.600000 0 _ 3 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 5 N=>NE Garage Frame-Wood 1 st Floor 11 19 9 8 8 171.2 ft2 0 0.01 0 -6 W=>NW Garage Frame-Wood 1st Floor 11 18 6 8 8` 160.3 ft2 0 0.01 0 r _ 7 N=>NE Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 _ 8 E=>SE Exterior Frame-Wood 2nd Floor 11 29 6 8 236.0 ft2 0 0.600000 0 _ 9 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 10 W=>NW Exterior Frame-Wood 2nd Floor 11 29 9 8 238.0 ft2 0 0 0.600000 0 _11 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1 st Floor None .2 3 6 8 20 ft2 2 W=>NW Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Law-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 13 ft 4 in None None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 48.0 ft2 1 ft 0 in 0 ft 10 in None None 4 S=>SW 11 Metal Low-E Double Yes 0.56 0.32 N 33.3,ft2 2 ft 0 in 0 ft 6 in None None 5 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft'0 in 0 ft 4 in None None 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 N . 16.0 ft2 1 ft 0 in 0 ft 4 in None None 7 W=>NW 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 4 in None None 8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 3 ft 5 in Drapes/blinds None 5/1/2018 1:11 PM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437 ft2 437 ft2 44 ft 8.6 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000319 2424.4 133.1 250.31 .2947 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 2 Electric Heat Pump/ None HSPF:8.5 17.7 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / --Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area `' Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 358.6 ft 1st Floor 89.6 ft2 Proposed Qn 1st Floor —cfm 53.8 cfm 0.03 0.60 . 1 1 2 Attic 6 221 ft2 2nd Floor 55 ft2 Proposed Qn 2nd Floor —cfm 33.1 cfm; 0.03 0.60 2 2 i 5/1/2018 1:11 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar A r Ma n Jun r Jul Au Se Oct Nov Dec Venting Jan Feb �Xj Mar �C�Apr v Dec May Jun Mar A Jul Aug Sep X�OctH NJun Jul A Oct ov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 l 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. „ FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 fl2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 fl2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.54 96.00 fl2 11.Ducts R ft2 a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor - 6 221 b. U-Factor: Dbl,U=0.56 64.00 fl2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 b.Central Unit 18.0 SEER:15.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.172 ft. b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average SHGC: 0.302 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2EF:0.95 b.Floor Over Other Space R=0.0 672.00 ft2 b. Conservation features c.other(see details) R= 437.00 ft2 None 15.Credits Pstat 1 certify that this home has complied with the Florida Energy Efficiency Code for Building �> S Construction through the above energy saving features which will be installed (or exceeded) in this home before final,inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feat es. Builder Signature: Date: 05/02/18 .� Address of New Home: 3184 Kresterbrooke Lane City/FL Zip: Zephyrhills. FL 33540=: *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge:com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 1:12 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 BuildingAnalysis Job: 2889A1sf ADS Carrier Y Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING ProjectInformation For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) a 39 17 Latitude: 28o N Relative humidity (/o) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 53.6 Dry bulb(°F) 31 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.5 6957 30.1 Ducts Glazing 30.2 3426 14.8 Doors 21.2 419 1.8 wall nfiltration Ceilings 1.3 1450 6.3 Floors 3.3 5951 25.8 Infiltration 2.1 2877 12.5 Ducts 2020 8.7 Piping 0 0 Floor; Humidification 0 0 Glazing Ventilation 0 0 over. Adjustments 0 Ceilings I Total 23100 100.0 Co6ling Component Btuh/ft2 Btuh % of load Walls 2.9 ,3724 20.0 Internal Gains Glazing 54.3 6167 33.2 Walls Doors 17.2 340 1.8 Ceilings 1.7 2021 10.9 Floors 0 0 0 p = Ducts Infiltration 0.5 684 3.7 Ducts 2360 12.7 Ventilation 0 0 Internal gains 3290 17.7 Infiltration Blower 0 0 Glazing Adjustments 0 Ceilings Total 18586 100.0 Other Latent Cooling Load=2305 Btuh Overall U-value= 0.107 Btuh/ft2-°F Data entries checked. =ightsoft- 2018-May-01 13:31:44 ^M�•k �• �^w Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCk ..ent\2889A1 sf ADS template 1.5-2ton Carrierrup Calc=MJB Front Door faces: W Job: 2889A1 sf ADS Carrier Building Analysis Date: 5/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 17 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 53.6 Dry bulb(°F) 31 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 3.8 3623 33.1 Duds Glazing 30.2 2386 21.8 Doors 0 0 0 Wall Ceilings 1.3 1384 12.6 nfiltration Floors 2.0 30 0.3 Infiltration 2.1 2121 19.4 Ducts 1402 12.8 Piping 0 0 other Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 10946 100.0 Component Btuh/ftZ Btuh l % of load Walls 2.9 2718 21.0 ntemal Gains Glazing 52.2 4127 31.8 Walls Doors 0 0 0 Ceilings 1.7 1874 14.5 Floors 0.9 14 0.1 ucts Infiltration 0.5 504 3.9 Ducts 1682 13.0 Ventilation 0 Infiltration Internal gains 2050 15.8 other Blower 0 0 Glazing Adjustments 0 Ceilings Total 12969 100.0 i Latent Cooling Load=2249 Btuh Overall U-value= 0.088 Btuh/ftZ-°F Data entries checked. wri-gF�tsoft0 2018-May-01 13:31:44 �CA ^�^k' .....,r,..,�..P Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W i Pro ect SummaryJob: 2889A1 sf ADS Carrier 0 Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure- 21080 Btuh Structure 16227 Btuh Ducts 2020 Btuh Ducts 2360 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23100 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18586 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1902 Btuh Ducts 403 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1793 1793 Equipment latent load 2305 Btuh Volume(ft') 16024 16024 Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 20891 Btuh ; Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 32 OF Backup: Input=6 kW, Output=22126 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - - wrightsoR® 2018-May-01 13:31:44 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 14C'C3` ...ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W Project Summary Job: 2889A1 sf ADS Carrier Date: 511/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING ! Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US I Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure I 9545 Btuh Structure 11287 Btuh Ducts 1402 Btuh Ducts 1682 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none i (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10946 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 12969 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1960 Btuh Ducts 289 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cooling (none) Area(ft2) 1103 1103 Equipment latent load 2249 Btuh Volume(ft3) 8824 8824 Air changes/hour 0.33 0.18 Equipment Total Load (Sen+Lat) 15218 Btuh Equiv.AVF(cfm) 49 26 Req. total capacity at 0.85 SHR 1.3 ton Heating Equipment Summary Cooling,Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC518AO0300 Cond 25HBC518AO0300 AHRI ref 9154643 Coil FB4CNP025L AHRI ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300 Btuh Heating output 17700 Btuh @ 47'F Latent cooling 2700 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point=20 OF Backup: Input= 3 kW, Output= 10697 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -�- wrightsoft� 2018-May-01 13:31:44 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ...ent\2889A1 sf ADS template 1.5-2ton Carrierrup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 2889A1 sf ADS Carrier Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.4°F Sensible gain: 18586 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.4°F Latent gain: 2305 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 20891 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 110% of load Latent capacity: 3600 Btuh 156% of load Total capacity: 24000 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 23100 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer:- Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18304 Btuh 79% of load Capacity balance: 32 OF Supplemental heat required: 4796 Btuh Economic balance: -99 OF i Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 6.5 kW 96% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. t wrightsoft® 2018-May-01 13:31:44 .aR• a-�*-owry�o�-� Right-Suite®Universal2018 18.0.16 RSU05714 Page 1 ...ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W i Manual S Compliance Report Job: 2889A1 sf ADS Carrier Date: 511/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.4°F Sensible gain: 12969 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.4°F Latent gain: 2249 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 15218 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 118% of load Latent capacity: 2700 Btuh 120% of load Total capacity: 18000 Btuh 118% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8'F Heat loss: 10946 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 13453 Btuh 123% of load Capacity balance: 20 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 3.1 kW 98% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. * wrightsoft® 2018-May-01 13:31:44 �.� .�.�,. •w gym„, Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 �'� ...ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: W PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG 21 E. — LOT 92 1 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89*40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT FT. EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA =_L7_L9_SQ. FT. ENTRY 26 UNDERGROUND FOOTER, STEM WALL, AND GARAGE FT. ---SO. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR COVERED LANAI FT. II SHOWN. PATIO = 23—SO. FT. 00 NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE =_._!6_L__SQ. FT. w NOTES TAKE PREFERENCE. A/C & CONC PAD =_ 18 SQ. FT. PRIVATE SIDEWALK = At_SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS PAGE INDICATES THAT PLAT IS IN, -_ 2645 —SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO Soo = 4397 _-SO. FT. CHANGE AND/OR REVISION, OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY =__q!taL_SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT, DRIVE APRON FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION Soo =­ll_1 ___SQ. FT. TO PROPERTY LINE. TOTALS PRELIMINARY DRAWING: AREA 7727.20 SQ. FT. THIS PLAN IS FOR PERMITTING PURPOSES DRIVEWAY =_ 5_0_Q _SQ. FT. ONLY, NOT FOR CONSTRUCTION. VERIFY SIDEWALK =__Z6_1 _SO. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SOD FT. LEGEND: NOTES: ---= PROPOSED DRAINAGE FLOW LOT GRADING TYPE = A (00.00) = PROPOSED GRADE PROPOSED PAD ELEVATION = N/A E-00.00 = EXISTING GRADE FRONT SETBACK = 20' = 10' DRAINAGE/UTILITY EASEMENT SIDE SETBACK = 10' = 5' DRAINAGE EASEMENT REAR SETBACK = 10' PLAT LU BOUNDARY CNI 01n. LOT 83 rl)CN NLLj N(� NC) 0— z 0 S 89'36'58" E 110.00' 0 a- uj� ----------- — --- Lj-j z C4: 0 1.............. Y_ ...... ....... . 4 1 2303' 87*01*16'E aaN ....... N 89-36 58- oa:<D" 5W-0- 31.03' "C 25.00' L CL O! A L) �—PRM(P) ow, I 'A (TYP) fj:_La�Ln ui a zm 0 20%50' 0) ow I— 0 5601 <= LLj of 0 C,4 10 . Id- ­­­ L GJ 0 1 � -1 Ax LOT 82 LOT 324 LU r�a> 1 0 0 0 a- ui HIDDEN RIVER PHASE ONE A: 6. CD. CD (PLAT BOOK 74, PAGES 101-121), A 2.92 s rollla*E Zo ry .... . C;. PLAT N 83*05'49" BOUNDAR W 10.COO, LOT 81 0,: If DESCRIPTION: PROPOSED: LOT 82, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", LOWEST FLOOR ELEVATIONS: AS RECORDED IN PLAT BOOK __ PAGES --- THROUGH LIVING AREA: 72.60' OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL I CURVE I RADIUS ARC CHORD BEARING DELTA DATUM OF 1929. MEAN SEA C30 510.00' 580 . 5 .00- 1 S 0338-37- W 06-31-0 400.00' LEVEL= 00.00 FT. C43 45.51- 45,49- 1 N 03-38-37" E 1 06'3VQ5)�� APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 (LEGEND;) C CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM*T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL 7042 Drawn By: Square Feet: --j— JOHN R.BEACH&ASSOCIATES,INC. sms .24 LENNAR HOMES SURVEYORS AND MAPPERS Checked By: t 911 WEST ST. PETERSBURG DRIVE ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1275 FAX (813) 855-8370 Scale: NOT VALID WITHOUT THE SIGNATURE AND Date of Survey: all THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM 4THN N4EACH )DATE LICENSED SURVEYOR AND MAPPER FLORIDA RN. LAND SURVEYOR No. 2984 L44493 Revisions: EL its # A _.��.�.....,..� WtLl �. �. , 26IL t A a I + _o �.__........._ --�ma 4*AllL " — ` zFF w _ ,..,.aa. . f ___. �_... .......� r ._.� VFF EL — 7A.18 113389 2287 _ a 7 74A � LLUU E _ � �...��fib, '.�.®....r.. : ....�,�. i •�� _.... d..'`� 73� i LAJ 140 F .E F3• } ..._.... __.... _...._ FP, ' . r R s� �, 84 j I ; FFB. iF®, -19 to 1 :�4331. fit.. FFM 1al . I'. LU 31 145 144g 314 fcx 146 Now KIP DATE 06/20/06 HIDDEN RIVER SUBDIVISION • f f lift i f lib iif if f f iif f ifif f lit i ffif f f lilt III�I if lii f lff f iif 2018127553 'Rcpt:1977661 Rec: 10.00 'IDS. 0.00 __ IT: 0.00 ;k07/30/2018 C. F. , Dpty 'Clerk .�PAULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER ' /30/2018 09:02am 1 of OR BK 9764 P13 99 Permit No. Parcel ID No 24-26-21-0100-00000-0820 NOTICE OF COMMENCEMENT' State of Florida County of Pasco THE'UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following Information is provided in this Notice of Commencement: I., Description of Property:Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 82 streetAddress: 31.84 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family-Residence Pool Screen Enclosure Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress S1. Ste 200 Tampa FL. 3360t Address - city State Interest in Property: Name of Fee Simple Titleholder: N/A (if other than owner) Address city State 4. Contractor. Lennar Hornes,-LLC. Name 4600 W Cypress St, Ste 200- Tampa FL,33607 Address city State Contractors Telephone No.: 813.574.5700 5. surety: N/A Name Address city State Amount of Bond: Telephone No.: 6. Lender: Name Address city State Lender's Telephone No.: 7. Persons.within the,State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St,Ste 200 Tampa FL, J;jt)U r Address city State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates. N/A Of to receive a copy of the Lienor's Notice as provided in Section 713.13(I)(b),Florida Statutes. Telephone'Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is.specified: WARNING To OWNER: ANY PAYMENTS MADE BY THE'OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER. PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS'TO YOUR PROPERTY: A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION IF-YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OFF PINEL COUNTY OF LAS Signature of Owner or Owners Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was-acknowledged before me this 30 day of March by Steve Robert Smith as V!I ce President (type of authaW,e—g—,—olffil—c-e'rwyustee,'aftomey in fact)for Lennar Homes, LLC (name of pal on be f yberri'instrument was executed). Personally Known 0 OR Produced Identification E] Notary Siomwu, Type of identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.625,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in It are true to the best of my knowledge and belief. Signature of Natural Person Signing Above wpdateibcs/bcs form. PASCO COUNTY bEVELO_PMENT SERVICES PAS C 8731 C16'e ns;Dtive Date: i 1/2/2018 C &N_Ty FLoRi]5AY New Port Richey,FL 34654 0113.11 SRWES.ORRANT DIAL Ts. 727-8474411 NOT A PERMIT Receipt#: 1806257 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 245031.00-329010 1.00 1399899 $12.58 $12.58 1806257 11/2/18 Waste Single,Family Permit 19985. TOTALS: $12'.68 $12.58 -Receipt# Paid By Check# CC Auth# Cashier ID Wbikstation Receipt Date Amt Paid 1806257 Check 1076129 556 BCCCP05W 11/02/2918 $12.58 Total Payments: $12.58 Pavor Address Phone Lenn r Co me 84 Kresterbrooke Lane I en dden River Subdivision 19 1 6S Wh114.uwIII be paying your bill with sco County Developmehtsarvices,_fha full amount of the credit card or echeci:fees,NOT shown above,Is collected by- First BI Ing payment services. MyReports/reports//PASCOPRODIPASCOIReceiptPOS—V6,rpt 11/2/2018 Page 1 of 1 ' I , 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3184 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-0820 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers j Use Classification: NOT APPLICABLE Permit Number: 19985 Date: 1 14/2018 ,i�� N l� � ISSUED BY• BUILDI OFFICIAL : WATER MUST BE CHANGED-OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE