HomeMy WebLinkAbout18-19988 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 19988
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION - _ LOCATION INFORMATION
Permit#:19988 Issued: 7/27/2018 Address: 3193 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet:- Est. Value: Book: Page:
Cost: 343,131.90 Total Fees: 18,447.97 Subdivision: HIDDEN RIVER
Amount Paid: 18,447.97 Date Paid: 7/27/2018 Parcel Number: 24-26-21-0100-00000-1210
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-363-2891
Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT
APPLICATION FEES
BUILDING FEE 1,875.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00
MECHANICAL FEE 184.80 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
( I
Inspections I Re• ired
FOOTER 2ND ROUGH PLUMB Mg INSULATION CEILING
FOOTER BOND DUCTS INSULATED SE ER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CbNtFR-CrdWS SI ATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Buildinand Cunshuctiun Scrviics i11CS)
PASC ., j
CC)UNTY �"LO1Z11�A� Blower Door Test Report Form
_ c� LAN Unit MP.pey
Add
KnkxkAk
pemdtr. 99 TenyWromparryNamc SKYFfEC
res:oate:- I� Zot8 reue,tw HASSENKHELIFI
testy Cen lt:MY3YG6 c�,t�rm.:904-903-1076
rmaj:hkhelifi@s1c etec.Com
402.4.1.2 Testing.Building envelope air tightttcss shall be demonstrated by Section 402A.1.2
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air change
per hour. Testing shall be conducted with a blower door at a pressure-of 0.2 inches w.g.(50 Pascals).As required by
the Building Official,testing shall be conducted by an approved third party.A written repot of the results of the test
shall be signed by the party conducting the test(including Agency game)and provided to the Building Official prior to
Certificate of Occupancy issuance:.Testing shall be performed at any time after creation of all scheduled penetrations of
the building thermal envelope
During testing:(check to verily concrWon met)
��Fxterwr windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weather-
stripping or other
I(Dampers including exhaust,intake,makeup air,backdroft and flue dampers shall be dosed,but not sealed beyond
V intended infiltration
r gInterior doors,if installed at the time of the test,shall be open
Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed
�Vmupapting and cooling systems,if installed at the time of the test,shall be turned off
ly and return registers,if installed at the time of the test,shall be fully open ti
Vb Building volume(fl') _ 7
Q50 Airflow at 50 Pascal(CFM) _
ACHso Air changes per hourat 50 Pascal: i
-, Q50 R 60 T Vb �t 17 ACHso(3.0 ACH minimum)
Pass Fail. ❑
Outside Air mechanically introduced to space(less than 3.0 ACH) I
1 We certify,that(he above envelope leakage performance results demonstrate compliance
IVA,F7oriild Energy Corte requirements in accordance Kith Section R402.4.1.2-
..�;�'ag ,StgnattueofTester
p+
kNA
.left Stream"' Ultra Blowing Wool Insulation
!
Attic and Cavity Wall Card *1 {wel >`01n Ir
Batts and Blankets Equipment Required �6' t> a ,�.a, tTlaf corrJgabon.a nxrtum wroth
tV!�, �a+ed r tr>axe rd a ma u� xFy 5 s reo�rnnend s e Ot't71 robe madare and a VtIe rdtgal feed rme a 5,35 tshrr+,fJ?RBConirrtended teed
n't.:'r-r'kr 13.�t`rs"a'�.!�5'�l'JJn!Ia'S 8nd l�lZ+tr3 Yb9 G'Si, te(',als tl C`e!f068 lKW tvt be1Ci5 C't� G+daRlCfPl
;r„yty�±'�R-,arx •a+e a 15-25 tt1s
R•Ya1ue' Mrnfinem 7itickness Thermal Performance(Sidewall and Attic Application)
a oaea;a m Ttie sxd E e tel ress!arme(R-ratW}a ac"dc*1 Dr MmhNn
x mmcnnon s�ra+e feet of c es
age Der recortnwa W by tabd
ua:.taDa.reustaxa hmaR.t nsdu�o.sbodd reoxed m-&,at btv per 1 Ow scxm f0et wA �
(R-Valve)af. t .et b.tau ma.: *A•evr9t'r b*-(r tAM R-+ryes Feld�^9 a des prNW"M oma tome►4 risuta*om a nU.reCarrriended DY the rer.
R•45 1375, Cavity Wal;Bag Net Weight-Nominal 32 lbs.,Minimum 311 lbs.
1025 - r 1000 SF Maximum Het Minimum
_ R 38 12 04 r�y R•Value• sags pc Coverage per Bag Weight per SF
_R-:No f 8 25' T.ir�asm t"1.M squmTb* of Dead Came.of mu Tl.�+rr$RUNS
Cavity d.K am ahedd W bag sb.N eat feel d l.st>!hd hfdmm
R-•'S � 19 0000' F
Depth raa�a Density tie seas tba.: rMar Do-arx. shoiad.ot be less the.:
R-22_j J 6 50 _ ' 3 50' R-15 1.a ihs foie tt 16 4 bags 61.0 5q.ft. 0.525�
R•21 HD 1 5 50' 6' ! 5.50- I R-23 18 Ibsla fl. 25A bags 38.8 sq.ft 0.825 ft.
R-19 6.25'" r 7.25- R-31 1 8�siai.ft. 34.0 bags 29.4 sq Pz 1.088 tbs.
R•1SHD 350'R_13 351 0' 9.25 R-39 1.8 Rnlw ft j 43 4 bags 23.1 sq.ft 1.388 bs•
R•t1 I 350' _ t`earm--Taos+*,o.va%x rr Vowee%trWq7ow apn e+eeurlda R-•r3re.rseaa"ed Tu rwak be n=WwOodl/
R-8 2 50 _
Ens --t- ks•u C.rd`.-'dTWP® Open Attic Application Bag Net Weight-Nominal 321bs,Minimum 31 lbs.
Minimum
Bags/ Maximum Minimum Initial Settler!
Framing Adjustment 1,000 SF Coverage Weight Installed Thickness"
--rrc,•k v i a s,g merCffs.1*caner of lays or The mi,b.r of bagsr rae.ea of au Tls W**zr f Thickness Contemb of Mh
sv' area t be r,-:cdEM so.*:be as slOvr.b" R-Value• 1.M 5>:d ret am bag sha*eot d tatuw kstan"iasdatiu bag shoWd
B a s1A1$F I Ba SIs1SF To obw.o maistim rbodd"he tau tared Ysdati"sbwd.a stwtld sot be has .a cow more
9 9 ,ssiatasda(R-Vdea)d: d=: oa.than_ be hu tbn On. ada:
Joist 16'O.C. 24-O.C.
R-60 29.7 33.6 SF .952 Ibs. 19.750' 19.750'
R-Value i Dimensions Framing I Framing
_ 2x4 292 294 R-49 23.5 42.5 SF .753 lbs. 16.375- 16.375-
R-60 r 2x6 28 o I 291 R•44 209 47.8 SF .6 0 bs. 14.875' 14.675'
2x8 28.6 T 289 R 38 17.8 56.2 SF .569 lbs. 13.0W 13.000'
2x4 23.0 �- 232 R-30 13.6 73.3 SF 437 lbs. 10.375' 10.375'
R-49 2x622.7 22.9 R-26 118 85-0 SF .377 lbs. 9.125' 9.125'
218 1 224 22•7 R-22 9.8 102.2 SF .3131bs. 7.750' 7.750-
2x4 1 20.4 20.6
R-44 2x6 20.1 1 203 R•19 8.4 119.3 SF .268 lbs. 6.750' 6.750'
Zx8 198 201 R-13 5.7 175.3 SF .1831bs. 4.750' 4.750'
Zx: 173 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000' 4.000'
R-38 i. 2x6 170 17.2
5C W eAq.-.-,j Z tL uron r u
Zx8 16.7 17.0 =,+;ea ++�as+...sr..easraw us�leo�aa...alPa.e,7pr q..q TcpwaGw..0 tscd r.c srtq 6aa0m
'�ea..K ram a�e,.rrm�gaa•.,aa75V C!N*la an Feva.S„dtaw,.wi�pa'ye+ 85tte a,e�rv.en ra,eM.m sm,.dc Sit
20 132 j 133 -�us„ess:an�.sea.rer�„r.ataetreymaennmm.wmre.,sresw.�teaaat::nauomx.aee[ropoq f p.S l}oi,t!pet rxiz
R-30 j 2x6 12.9 131 m.,amnercaewr�c,mmme:nemeb
'S ent v'+sSDa.,:T•�'G�-Y tt eroSa,c�.^e�ar,3}ri.Dr�d1f oe::vIDa n kn In annn d sarq acx.alp cyjfepX neebe n+sarW/<feOC
2xB 12.6 12.9 rax,rae,ts�ngaessx
2x4 113 11.4 'huatlrt.,,eya.e:idvarrdtrai
-- 2x6 11.0 11.2 Builders Insulation Statement
2x8 10.8 11.0 Jet Strearn Ultra has been istOW m ombimance v4 the included recot nendabons to provide a tttermw tesssta m of..
I` + 2x4 9.3 95 R-Value Thickness
'x6 9.1 9.3 AtibArea R- at inches8 8 9.1 Cehngs R- at Inches
E
_ T.9 8.1 Wks R- at Inches
7 7 7.9 Floors(over an unhealed aa»i
74 7.7space) R- at inches
53 54 CraiM Slime Pen R- at lrt es
[x5 5.0 5.2 Date Installed
26 4.8 5.0 sulation has been' infhe wrilormance mth above reco n e an R-value of:
2x4 4.3 4.4 R using bags of this hmiabon to square feet of area
R-11 2x6 4.1 4.3 at a mini m rn tffi vemm of f
1x8 3 B I 4.1 �-irrCiles.
m� is 3;aor Ca racm t ^
W f�1 cars- rV
'E-.�...,c+cevw w,e
k�a.;' asrnaouara Ho ne 9sds tsaaare}
5, -A
:xncwc,�s,,a. Carr
a•ory ve ltdr8 '
` The coverage inbr"'ttion on this AttidSideaal(card applies to the entire United States(including Minnesota).
www,knaofinsuta Han.us Knauf Insulation,Inc. One Knatd Drive Sheb}•vt8e.IN 46176 Tet.(800)8254434 ext-M FAX-(317)39&3675
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, August 8, 2018 12:33 PM
To: Jacqueline Boges
Subject: [Request received] 3193 kresterbrooke lane by#19988
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfi.zendesk.com/hc/requests/232259
.......................................................................................................................................................................................................................................................................................................................................................................................
jJacqueline Boges
L — —` Aug 8, 9:33 AM MST
full service 3193 kresterbrooke lane by#1 9988 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
\
n 813-780*020 ' ' City of Zephyrhills Permit Application Fn»813-780-002
Building Department
Date Received MAY 0 3 2018 Phone Contact for Permittin F-813 363 "2891
Owner momn o�no ��vnomumuu
Owner's Address 4600 ress FL 33607 Owner pxpnom'umbe
Fee Simple Titleholder momv I Owner Phone Number .
Fee Simple Titleholder Address N/A
SuBmvsxoN Hidden River Phase Onep/wxcsL|o# 0100-00000-121-0
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED wmvoowsrn mzo6Acr F--1 SIGN F--| F--1 DEMOLISH
INSTALL L_� REPAIR
PROPOSED USE .'_GFR F—� COMM F--� OTHER
TYPE OF CONSTRUCTION uO 'n F—� FRAME �---1 STEsL �--1
Single Family Residence Pool/Screen Enclosure/Fence
DESCRIPTION OF WORK
BUILDING SIZE [ WR IF 3046 SCI FOOTAGE HEIGHT 12 Story
JOBUILDING 1$ 1qz 12=0 VALUATION OF TOTAL CONSTRUCTION
0 ELECTRICAL r- I AMP SERVICE
�� UPLuMB|No
��
V� AMECHANICAL VALUATION OF MECHANICAL INSTALLATION
=oAa ROOFING �—1 SPECIALTY OTHER
OTHEn
--- T— LU [---1
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES � �o �
---' ----
Bu/cosm COMPANY Lennar Homes,LLC
S/om/nnRe REGISTERED LYl N pcsounnsN
Address 14600 Uuanuo# .
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y2 NL—] pssoonnsx LZ2N—J
xudmms 11034 Skioer Road,Tampa, FL 33613 Licehno#
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED _Y/lN J pEsuunnEx LILN_j
Address Unwmo#
MsoHAm|ovL COMPANY Bayonet Plumbing, Heating &AG,
SIGNATURE REGISTERED _I/ NL rssconnsx LY/NP.O. Box-W8, Bayonet, FL 34674-5308
_�
Address License f
OTHER COMPANY
mam/nnms REGISTERED _Y/ N_J pescuneEx
Address Ummma#
mmxoxuxmxnnxnumumxuuouumxmxwununonmomnnoomnwxounuuu � xunoumumxxxomnm
RESIDENTIAL Attach(2)Plot Plans;Vg sets of Building Plans;(1)set o[Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)wm,Wngumm after submittal date. Required onaita.Construction Plans,amnn*emc Plans vl Silt Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach;g complete sets or Building Plans plus a Life Safety Page;(1)set of Energy Forms.R.O4wPevmit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,St6rmwater Plans w/Silt Fence installed,
Sanitary Facilities m 1 uumpstsr.Site Work Permit for all new projects./w|xommom|o|ranuiemomu mum meet compliance
SIGN PERMIT Attach(2)sets vf Engineered Plans. �
=^^pRoPEnTY SURVEY required for all NEW construction. `
Fill out application completely.
Owner&Contractor sign back nf application,notarized
|f over$uano.a Notice v[Commencement|nrequired. Vxo upgrades over$7smN '
� Agent(for the contractor)or Power o f Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy mcontract required) /
Romofs if shingles Sewers 8eo4ue Upgrades /VO Fences(Plot/Survey/Footage)
DrivGways-Not over Counter ifuo public mudwuye.naodoROVY
'
Lennar Homes-3193 Kresterbrooke Lane 3,046 sq ft
o umn
SQ. FEET PRICE
MAIN OR LIVING: 3,046 $ 112.65 I
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 343,131.90
FEE SHEET $ 1,760.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,875.20
ELECTRICAL: $ 396.00
PLUMBING: $ 264.00
MECHANICAL: $ 184.80
SUB-TOTAL $ 2,720.00
Public Fee 1%
TOTAL $ 2,720.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,847.13
j
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ . 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,447.97 ;
24-26-2 1-0 1 00-00000-1210 j Pasco County Property Appraiser Page 1 of 1
I
Data Current as Of: Weekly Archive - Saturday, July 14, 2018
Parcel ID 24-26-21-0100-00000-1210 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $27,540
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3193 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540
Just Value $27,540
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 121 Taxable Value $27,540
OR 9750 PG 2604
Jurisdiction
City of Zephyrhills
Land Detaif(Card: 001 of 001)
Line _ Use escription4oning�Units Type (Price Condition alb-ue
_1 0100 � D���SFFR I MPUD 6,000.00 �SF--�"j $4.50 1.00�$27,000 !
2 �� 0100 ! SFR MPUD_]_600.00 SF 90i 0 j 1.00 j $540
_ Additional Land Information
FEMA
Acres 0.15 Tax Area 30ZH Code -- Residential Code HDRVLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001) _
Line J~_�� ___Description ®� ea �_ � _Units _ ijValue
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page y�IType O Code Condition -[Amount _
06/2018 9750 / 2604 _ Warranty Deed 05 _ Vacant I Multi-Parcel Sale
09/2011 8606 / 3376 Warranty Deed 05 Vacant j Multi-Parcel Sale
06/2010 8360 / 1872 Certificate of Title ( 12 Vacant I $0
i
i
I
i
i
I
i
I
http://search.pascopa.com/parcel.aspx?parcel=2126240100000001210 7/18/2018
I
--------- —
I
PASCO COUNTY, FLORIDA
Permit No.
//'
Date Permitted —/B— F
Builder Name/Owner Name �r` L"ntrol#'
County Parcel No. 2,4=4-24-6(dd-&M - 12f d SubDiv: 1-Mlydez 4!bW_1
Address/Location Ld,,e—
';` Classification/Type of Use c5��tn
c:::•:, TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: ��
I., Exempt ❑Yes R No How Determined
k-' Impact Fee Amount $. , Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family 1)etached House Amount $ 7
f: (067) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes Q No How Determined
PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
t Exempt Yes No How Determined
.`1-
? LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes No How Determined Total Amou
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
3' i
i
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of•a copy of this form,placing
the building permit owner,on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E.
LOT 121 BEARING BASIS:
HIDDEN RIVER PHASE ONE 3 NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
LOT FT, EASEMENTS AND RESTRICTIONS OF RECORD.
LIVING AREA =_1QqZj_SQ. FT. UNDERGROUND FOOTER, STEM WALL, AND
ENTRY FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR
GARAGE FT. II SHOWN.
COVERED LANAI =_.N1A___SQ. FT.
PATIO =-23----SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
CONC. DRIVE FT. tii NOTES TAKE PREFERENCE.
A/C & CONC PAD =_15,_—SQ. FT. <
0 PRIVATE SIDEWALK =_11___SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
En
IMPERVIOUS = 31 q PAGE INDICATES THAT PLAT IS IN
+=_20_4fi_SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO
SOD =_AaQ5__SQ. FT. CHANGE AND/OR REVISION.
CERTAIN DATA SHOWN HEREON BASED ON
RIGHTOFF L WAY =OT AREA CALCULATIONS SQ. FT.ULATIONS ENGINEERING PLANS PROVIDED BY CLIENT.
OF __L2_Q_QCL
DRIVE APRON FT. STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
SOD 336---SQ. FT. TO PROPERTY LINE.
TOTALS PRELIMINARY DRAWING:
AREA = L,3_29_-CL0_SQ. FT. THIS PLAN IS FOR PERMITTING PURPOSES
DRIVEWAY FT. ONLY, NOT FOR CONSTRUCTION. VERIFY
SIDEWALK =_22_1SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
SOD 4901—SQ. FT.
LEGEND:
NOTES: = PROPOSED DRAINAGE FLOW
LOT GRADING TYPE = A (00.00) PROPOSED GRADE
PROPOSED PAD ELEVATION = N/A E-00.00 = EXISTING GRADE
FRONT SETBACK = 20'SIDE SETBACK = 10' 10' DRAINAGE/UTILITY EASEMENT
REAR SETBACK = 10'
PLAT LOT 122 PLAT
BOUNDARY BOUNDARY
LOT 103
HIDDEN RIVER PHASE ONE A
(PLAT BOOK 74, PAGES 101-121)
S 89*36'58" E 110.00'
. .......25 LLJ
.. ....... .....
8 I71
25.50'
0 46.5 0'
z
0 A b -c, 84
to 0 ip 0 0
C> 0
,5 6'. \_1(Wn
LO
LOT 104 LU roO 0 CL
HIDDEN RIVER PHASE ONE A LOT 1 0 CIJ
21 in Lr) af
•
a_ Ld 0
(PLAT BOOK 74, PAGES 101-121) -c\j 2 V2�6�6 6
0 ai -0 ry W tr)
W I >
a-CL Ld
.p W
< .... .
< .......�,50'
0 m c)z
m
ry L'i
Q
0 43'-0"
46.50 25.5 0'
...........
-o C,:
31"
N 89'36'58" W 110.00'
N 89-3.6',5p'
PRM(P)—/. 25.00
(TYP)
LOT 105
HIDDEN RIVER PHASE ONE A
(PLAT BOOK 74, PAGES 101-121) LOT 120
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 72.80'
DESCRIPTION: GARAGE AREA: N/A
LOT -121, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", ELEVATIONS REFERENCED TO.NATIONAL GEODETIC VERTICAL
AS RECORDED IN PLAT BOOK __ PAGES --- THROUGH DATUM OF 1929. MEAN SEA
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992
ILEGEND.
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
ICONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED,
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No, 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U/P= UTILITY POLE, W/F= WOOD FENCE. (R) = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6600.00 t LENNAR HOMES
SURVEYORS AND MAPPERS Checked By:
t 911 WEST ST. PETERSBURG DRIVE JRB
ONE OLDSMAR, FLORIDA 34677
WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30-
NOT VALID WITHOUT THE SIGNATURE AND jDote of Survey:
THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/19/2018 RTM R. BEACH DATE
LICENSED SURVEYOR AND MAPPER "FLORID EG. LAND SURVEYOR No. 2984 LB#4493
Revisions:
.._. I t .. � �.-..,ti�� rr .W.9v�rY.{�,� L Yln.w�IIu w.9 ._...u�.W,-s.wwn�,r ��6 •�.
J.
'A LAJ
LU
3 = FIFA'ass .124�F I
.
HHH
FF—
t,7�A
WA A
r. 1
Ll34
'
123
A
1103
FF EL
5 ' ryJy t1 y ,_ 'Ag
'.
ffA
rk:."""�
lb
r• Fr-�
7 FF EL
r A AA
A d •
FFEL
VIM 1
FFEL
L �. �` ` i.
119
$ *�. EL
dw
110 el
LAIJ
AT -VD" SHE
SCALE
and Associates., Inc. DESIUMM RT
-0400 FAX (103) a82-jM CHECKED BY
i
� Y
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3193 Kresterbrooke Lane Permit office: CN
�„Z,�prhills
City,State,Zip: ,FL, Permit Number: Z�3
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent' R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sgft.) Insulation Area
a.Under Attic(Vented) R=30.0 1491.00 ft2
6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl, U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2584.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1051.00 ft2 None -
c.other(see details) R= 440.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 74.91 PASS
Glass/Floor Area: 0.068 Total Baseline Loads: 74.82
I hereby certify that the plans and specifications covered by Review of the plans andT1iE:ST ..
this calculation are in compliance with the Florida Energy specifications covered b this O =:P 9Y P Y
Code. calculation indicates compliance
Dave
AG/- with the Florida Energy Code. F+' hht = „ O
PREPARED BY: tt h Before construction is completed
DATE: this building will be inspected for �� :
compliance with Section 553.908
hereby certify that this building,as desi ed, is in compliance Florida Statutes.
with the Florida Energy Code. COrj`y ;
OWNER/AGENT: MAY O 3 2018 BUIL`'DING OF �IA
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.050 Qn for whole house.
5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3193 Kresterbrooke Lane Pen-nit office: City of ZephyrhjIlS
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftZ
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1491.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ft2
6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R=. ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features EF:0.950
b.Floor Over Other Space R=0.0 1051.0.0 ft2 None
c.other(see details) R= 440.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 74.91
Glass/Floor Area: 0.068 PASS
Total Baseline Loads: 74.82
i
hereby certify that the plans and specifications covered by Review of the plans,and TkI>�isA
this calculation are in compliance with the Florida Energy specifications covered b this O .
P 9Y P Y
Code. calculation indicates compliance
�aVe7✓�G� with the Florida Energy Code.
PREPARED BY: GUL Before construction is completed'
DATE: this building will be inspected for � •. ( l,-p.. -_. �;,
compliance with Section 553.908 *• . $,
hereby certify that this building,as designed, is in compliance Florida Statutes. a
with the Florida Energy Code. MAY o 3 2018
OWNER/AGENT: BUILDING OFFICIAL-
DATE DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory�sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:45 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3193 Kresterbrooke Lane Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 61.1600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
I
I
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sgft.) Insulation Area
2. Single family or multiple family Single-family
a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 ' 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1491.00 ft2
6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N R= ft2
11.Du c. s R ft2
7. Windows(175.6 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor. Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2584.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1051.00 ft2 None
c.other(see details) R= 440.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 74.91
Glass/Floor Area: 0.068 PASS
Total Baseline Loads: 74.82
hereby certify that the plans and specifications covered by Review of the plans and SSA this calculation are in compliance with the Florida Energy specifications covered by this
,
Code. calculation indicates compliance yw'r, - - s.
0.
with the Florida Energy Code. t.%; ?.;,•�`" n .0
PREPARED BY: Dave AUPich Before construction is completed sir C I
DATE: this building will be inspected fore
compliance with Section 553.908
I herebycertify that this building,as des' ned, is in compliance Florida Statutes.
fY 9� p
with the Florida Energy Code. 'Otj
MAY 0 3 2010 , '
OWNER/AGENT: BUILDING OFFI L
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.050 Qn for whole house.
i
I
i
5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
ti
FORM R405-2017
PROJECT
Title: 2575A1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2584 Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 270 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC, 2017
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1093 9399.8
2 Block2 1491 11928
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 istFloor 1093 9399.8 Yes 0 1 Yes Yes Yes
2 2nd Floor 1491 11928 No 5 4 1 Yes Yes Yes
FLOORS
!
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet P
1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 0.3 0 0.7 !
2 Raised Floor 2nd Floor — 13 ft' 11 0 0 1
3 Floor over Garage 2nd Floor ---- 427 ft' 11 0.2 0 0.8
4 Floor Over Other Space 2nd Floor ---- 1051 ft' 0 0.2 0 0.8
i
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1615 ft' 0 ft' Medium 0.85 No 0.9 No 0 22.6 !
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1491 ft' N N
5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1491 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 N=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0
2 E=>N Exterior Concrete Block-Int Insul 1 st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0
3 S=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0
4 W=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0
5 N=>W Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0
6 W=>S Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0
7 N=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
8 E=>N Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0
9 S=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
10 W=>S Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0. 0.600000 0
11 S=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>W Insulated 1 st Floor None .2 3 6 8 20 ft2
2 N=>W Wood 1st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
3 S=>E 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None
4 S=>E 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
5 N=>W 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None
6 S=>E 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
7 W=>S 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>W 7 Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
9 S=>E 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in' Drapes/blinds None
10 N=>W 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 427 ft2 427 ft2 41 ft 8.6 ft 1
5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
i
FORM R405-2017
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000367 2488.2 136.6 256.9 .339 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 18 kBtu/hr 540 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
V. FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool j
1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 54.7 cfm 0.05 0.60 1 1 `
2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 74.6 cfm 0.05 0.60 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:,
Cooling [[ ]]Jan [[ ]]Feb [[ ]]Mar [ ]A r I
jMa
May [X]Jun [X]Jul [X]Aug' X]Se [ ]Oct [ ]Nov [ ]Dec '
Heatin [X]Jan [X]Feb [X]Mar [ ]Apr y [ ]Jun [ ]Jul [ ,]Au 4 ]Sep [ ]Oct [X]Nov [X]Dec
Ventin [[ ]]Jan [[ ]]Feb [[X]]Mar [X]A r May [ ]Jun [ ]Jul [ ]Au [ ]Se [X]Oct [X]Nov [ ]Dec
li
5/1/2018 8:45 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
i
r
FORM R405-2017
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
I
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
i
I
i
r
j
i
5/1/2018 8:45 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
j
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ft2
6. Conditioned floor area(ft2) 2584 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.54 71.25 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
b. U-Factor: Dbl,U=0.56 71.00 ft2
SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 18.0 SEER:15.00
SHGC: SHGC=0.32 b.Central Unit 24.0 SEER:15.50
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 17.7 HSPF:8.50
Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2EF:0.95
b.Floor Over Other Space R=0.0 1051.00 ft2
c.other(see details) _R= 440.00 ft2 b. Conservation features
None
15.Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for Building
THE ST
Construction through the above energy saving features which will be installed (or exceeded) O Fo.
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,:'`�r� •=' ,,.,*�;,i,`,
based on installed Code compliant f t �o
Builder Signature: Date: 05/02/18
.*.. ..
Address of New Home: 319 Kresterbrooke Lane City/FL Zip:ZeFhyrhills,FL 33540
OD-WEB
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
i
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/1/2018 8:47 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
i
BuildingAnal Job: 2575A1 sf ADS Carrier
Y$I$ Date: 5/1/2018
lower floor By: Dave
BAYONET PLUMBING COOLING HEATING
Project I • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 38 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb ff) 32 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb (°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ftz Btuh % of load
Walls 5.3 5016 31.8 ucis
Glazing 29.2 2565 16.3 nfiltration
Doors 22.7 450 2.9 wall
Ceilings 1.7 55 0.4
Floors 4.0 4329 27.5
Infiltration 1.9 1966 12.5
Ducts 1368 8.7
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Doors Other
Adjustments 0
Total 15750 100.0
Component Btuh/ftz Btuh % of load
Walls i 2.8 2669 23.5 ! Internal Gains
Glazing 56.3 4953 43.6 wall
Doors 18.6 368 3.2
Ceilings 2.0 65 0.6 Ducts
Floors , 0 0 0
Infiltration 0.4 456 4.0
Ducts 1657 14.6 nfiltration
Ventilation 0 0 other
Internal gains 1200 10.6 Doors
Blower 0 0
Adjustments 0
Total 11368 100.0 Glazing
Latent Cooling Load= 1216 Btuh
Overall U-value= 0.150 Btuh/ftz-°F
Data entries checked.
` -Fp- wrightsoft- 2018-May-01 09:13:07
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCK ..ment%2575A sf ADS template 1.5-2ton Carrier.rup Cale=MJ8 Front Door faces: E
i
Building Analysis Job: 2575A1 sf ADS Carrier
Y Date: 5/1/2018
upper floor By: Dave
BAYONET PLUMBING COOLING HEATING
Project I • •
For: Lennar Homes
I
Design Conditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (OF) 38 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb (OF) 32 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
i
Component Btuh/ft2 Btuh % of load
Walls 3.7 4115 32.5 ucts
Glazing 29.2 2676 21.1
Doors 0 0 0 walls
Ceilings 1.2 1808 14.3 nfiltrafion
Floors 0 0 0
Infiltration 1.9 2258 17.8
Ducts 1805 14.3
Piping 0 0
Humidification 0 0 Ceilings E'
Ventilation 0 0 Glazing
Adjustments 0
Total 12662 100.0
Cooling
Component Btuh/ft2 Btuh % of load
Walls 2.8 3160 17.4 walls
Glazing 54.0 4951 27.9 Internal Gains
Doors 0 0 0
Ceilings 1.7 2598 14.6
Floors 0 0 0
Infiltration 0.4 523 2.9
Ducts 2140 12.0
Ventilation 0 0
Internal gains 4462 25.1 Glazing Ducts
Blower 0 0
Adjustments 0 Infiltration 1
Total 17774 100.0 Ceilings
Latent Cooling Load= 3317 Btuh
Overall U-value= 0.084 Btuh/ft2-°F
Data entries checked.
-�- wrightsoft® 2018-May-01 09:13:07
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...ment12575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E
Project Summary Job: 2575A1 sf ADS Carrier
1 Date: 5/1/2018
lower floor By: Dave
BAYONET PLUMBING COOLING HEATING
—Project Information
For: Lennar Homes
Notes: FBC 2017
Design Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14382 Btuh Structure 9711 Btuh
Ducts 1368 Btuh Ducts 1657 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 15750 Btuh Use manufacturer's data
Rate/swing.multiplier 1.00
Infiltration Equipment sensible load 11368 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 925 Btuh
Ducts 291 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft') 1093 1093 Equipment latent load 1216 Btuh
Volume(ft') 9641 9641
Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12584 Btuh
Equiv.AVF (cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton
J
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC518AO0300 Cond 25HBC518AO0300
AHRI ref 9154643 Coil FB4CNP025L
AHRI ref 9154643
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 15300 Btuh
Heating output 17700 Btuh @ 47°F Latent cooling 2700' Btuh
Temperature rise 27 OF Total cooling 18000 Btuh
Actual air flow 600 cfm Actual air flow 600 cfm
Air flow factor 0.038 cfm/Btuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Capacity balance point= 31 OF
Backup:
Input=4 kW, Output= 15295 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- - wrigF�tsoftm 2018-May-01 09:13:07
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
'`�'� ...ment\2575A sf•ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E
Job: 2575A1 sf ADS Carrier
Project Summary Date: 5/1/2018
upper floor By: Dave
BAYONET PLUMBING COOLING HEATING
Project •
For: Lennar Homes
i
Notes: FBC 2017
Design Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10857 Btuh Structure 15634 Btuh
Ducts 1805 Btuh Ducts 2140 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0, Btuh
none (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12662 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17774 Btuh
I
Method Simplified Latent Cooling Equipment Load Sizing j
Construction quality Semi-tight
Fireplaces 0 Structure 2943. Btuh
Ducts 374 Btuh
Central vent(0 cfm) 0 Btuh
Heating cooling (none)
Area(ft2 1491 1491 Equipment latent load 3317 Btuh
Volume(ft') 12077 12077
Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21091' Btuh
Equiv.AVF (cfm) 54 29 Req. total capacity at 0.85 SHR 1.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.063 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point= 17 OF
Backup:
Input= 3 kW, Output= 11787 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Fk- wr1ohtsoft- 2018-May-01 09:13:07
•�^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
�` ...ment\2575A sf ADS template 1.5-2ton Carrier.rup Calc=MA Front Door faces: E
Manual S Compliance Report Job: 2575A1 sf ADS Carrier
Date: 5/1/2018
lower floor By: Dave
BAYONET PLUMBING COOLING HEATING
Project Information
I
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 11368 Btuh Entering coil DB: 75.8°F
Outdoor design WB: 77.2°F Latent gain: 1216 Btuh Entering coil WB: 62.9°F
Indoor design DB: 75.0°F Total gain: 12584 Btuh
Indoor RH: 50% Estimated airflow: 600 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Sensible capacity: 15300 Btuh 135% of load
Latent capacity: 2700 Btuh 992% of load
Total capacity: 18000 Btuh 143% of load SHR: 85%
I
Heating EquipmentI
Design Conditions
Outdoor design DB: 32.1°F Heat loss: 15750 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Output capacity: 13793 Btuh 88% of load Capacity balance: 31 °F
Supplemental heat required: 1957 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 600 cfm
Output capacity: 4.5 kW 97% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
L Wrightsaft- 2018-May-0109:13:07
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...ment\2575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E
i
Manual S Compliance Report
Job: 2575A1 sf ADS Carrier
Date: 5/1/2018
upper floor By: Dave
BAYONET PLUMBING COOLING HEATING
Project I • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 17774 Btuh Entering coil DB: 75.7°F
Outdoor design WB: 77.2°F Latent gain: 3317 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21091 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
c
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 115% of load
Latent capacity: 3600 Btuh 109% of load
Total capacity: 24000 Btuh 114% of load SHR: 85%
i
Heating Equipment
Design Conditions
Outdoor design DB: 32.1°F Heat loss: 12662 Btuh Entering coil DB: 69XF
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 24000 Btuh 190% of load Capacity balance: 17 °F I
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 3.5 kW 93% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
- wrightsoft- 2018-May-0109:13:07
Right-Suite®Universal 201818.0.16 RSU05714 Page 2
' ...ment\2575A sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces: E
Sing e Fami y Dwe ing
Plan ReviewComments.
m ments .
1: F.F.E. shall be'a minirnum.of 8"above-the road.elevation;and an engineered site plan.
2. Lots.shall be graded to comply with R401.3 of the F.B;C:
3. :Compaction test required.if 24 or more:of fill dirt is.brought.in:ai any one place:
4: .Tie in survey required before pouring concrete.
5. _ Driveways.require a R.O.W. use permit:: All 4sides of driveway.thru the sidewalk shall
expansion material:.
6. All setbacks.shall be met.:.
7. .1I-property.markers shall be_uncovered and marked at time of first 'inspection.
8:. All A.D.A:requirements.shall be met.:
9. No:electric;plumbirg, mechanical;,or framing shall be covered without an,inspection and
approval first. .
10.-All Garages shall comply-with section R302.6:of,the F.B:C:: Fire Separation)..
11:Appliances:shall iiot:be installed ina location where subjectto.niechanical daniage'unless
protected:by approved barriers. M303.4 o£the F.B.C.
12. Water heaters shall comply:with section.P607,3.of the F:B.C.
13. Foundation supports for.A/C units-shall be raised at least 3 above finished grade. M1308..1.
14.Return air in all bedrooms..F:B.C. M,1620.4,
15. Smoke detectors are.to be installed.in accordance.with:R313:.1 of ffie.F.B.C.
16: All glazing requirements are:.to be in accordance with R308.4-of the.F.B.C.
17. All means.of egress are to be in accordance with R31_L of the R.B.G.. ::
18."Green gypsum board"shall not be used as backer in hoovers or tubs. R702:4,2,F.B.C.
. :
19.-'Combination-type AFCI-breakers are,required;of all,locations re.quirma an AFCI,type breaker: ,
20. Carbon monoxide.alarms will be required in now:construction that uses_fossil-burning:heating
or appliances-or an attached garage.,They shall be installed in accordance with the VRC:
21. All plumbing, mechanical,-and.electrical shall be separate from unit_to:unit: This includes all.
underground plumbing Arid electric.
22.-All 2016:N.E.C; Codes.will be enforced.
23:Tamper=Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24:In accordance with the Land Development Code,.lots.shall be sodded before final at least 10
feet around:the structure..
25. Blower door test and blown in insulation card shall be provided:before C:O.
26. A cobv ofthe enetgy cacls.shall be with permit atall tinier
27 Copy of final insulation reyort shall be*ovided-with:permit before.final
F.F.E.-Finished Floor Elevation
F:B.C=Florida Building Code 6t'Edition -
R.O.W.:-Right of-Way-
A'.D,:A..Americans with Disabilities Act N.E.G.-:National Electric Code(20i1)
i
Lennar Homes-3193 Kresterbrooke Lane-3,046 sq ft
I
Column
SQ:FEET PRICE
MAIN OR LIVING: 3,046 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
i
OTHER: - $ -
VALUATION $ 343,131.90
FEE SHEET $ 1,760.00
ADDRESS $ 30.00
DRIVEWAY1 $ 45.00
BUILDING: $ 1,875.20
ELECTRICAL: $ 396.00
PLUMBING: $ 264.00
MECHANICAL: $ 184.80
SUB-TOTAL $ 2,720.00
TOTAL $ 2,720.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
i
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,847.13
. i
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
i
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,447.97
�IINII lull hill llNl IIIN lllll�lllli lilll illll illll Illl III
2018127557
Acpt:1977661 Rec: 10.00
DS: 0.00 IT: 0.00
.07/30/2018 C. F. , Dpty Clerk i
.PAULA S.0-NEIL,Ph.D.PASCO CLERK & COMPTROLLER
:07/30/2018 09:02am I of I
OR BK 9764 Pr- 103
Permit No. Parcel ID No 24-26-21-0100-00000-1210
NOTICE OF COMMENCEMENT
state of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 121
Street Address: 3193 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence Pool Screen Enclosure Fence
3. Owner Information: Lennar Homes,LLC.
Name
4600 W Cypress St. Ste 200 Tama FL-33607
Address city State
Interest In Property:
Name of Fee Simple Titleholder: -N/A_
(If other than owner)
Address city State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address city state
Contractor's Telephone No.: 813.574.5700
5. surety: .t , N/A
Name
Address city State
Amount of Bond: $ Telephone No.:
6. Lender:. N/A
Name
Address city State
Lender's Telephone No.:
7. Persons within the State of-Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 71.3.13(1)(a)(7),Florida Statutes:
Lennar Homes LLC
Name
4600 W Cypress St, Ste 200 Tampa FL,336071
Address city State
Telephone Number of Designated. Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713:13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Offic6r/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing-instrument was acknowledged before me this_LO day of March ,by
Steve Steve Robert Smith —as Vice President (type of authorit aW_Dfflcer,trustee,attorney In fact)for
Lennar Homes, LLC (name of pa onbehalf of wh i rument was executed).
Personally Known A OR Produced Identification M NotaryEftpature
Type of Identification Produced Name(Print) Ellssa Holleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge.and belief.,
Signature of Natural Person Signing Above
wpdata/bcs1bcs form!,