HomeMy WebLinkAbout18-20092 i
CITY OF ZEPHYRHILLS
5335-8th Street
(813)780-0020 0092
ELECTRICAL PERMIT
PERMIT INFORMATION - LOCATION INFORMATION
Permit#:20092 Issued: 8/14/2018 Address: 5329 17TH ST
Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL.
Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range:
Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 19,470.00 Total Fees: 277.50 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 2-'7'7.60 Date Paid: Parcel Number: 11-26-21-0010-17200-0130
CONTRACTOR INFORMATION OWNER INFORMATION
Name: SUN-T.E.0 Name: JOHNSON WILLIAM O & LAURIE L
Addr: 4625 EAST BAY DR#305 Address: 5329 17TH ST
CLEARWATER, FL 33764 ZEPHYRHILLS, FL. 33542
Phone: (727)571-4141 Lic: Phone: (813)780-6143
Work Desc: INSTALLATION SOLAR PHOTOVOLTAIC SYSTEM W/ELECTRIC
. APPLICATION FEES
ELECTRICAL FEE 67.50 BUILDING FEE 210.00
INSPECTION REWIRED
ROUGH ELECTRIC
CONSTRUCTION POLE
PRE-METER l f
FINAL /
J
REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City
Codes and Ordinances.
CONTRACTOR PER OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780.0021
Building Department
Date Received
Phone Contact for Permitting
Owners Name William Johnson Owner Phone Number 231-499-9959
ownees Address 532416TH ST,ZEPHYRHILLS, FL 33542 Owner Phone Number 813-780-6143
Fee Simple Titleholder Name Owner Phone Number
I
Fee Simple Titleholder Address
JOB ADDRESS 5329 17TH STREET,SEPHYRHILLS, FL 33542 LOT# 13& 14
SUBDIVISION PARCEL ID# 11-26-21-0010-17200-0130 "
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR B ADD/ALT = SIGN = = DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR = COMM. = OTHER
TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL =
DESCRIPTION OF WORK Install Solar photovoltaic System
BUILDING SIZE SO FOOTAGE HEIGHT
OBUILDING $19,370 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL '100.00 AMP SERVICE = PROGRESSENERGY = W.R.E,C.
=PLUMBING $ IT
✓�
=MECHANICAL $ VALUATION OF MECHANICAL INSTeTIbN
(�
=GAS = ROOFING = SPECIALTY = OTHER N
FINISHED FLOOR ELEVATIONS I I FLOOD ZONE AREA =YES NO C-JLco(/
1
BUILDER .r (D COMPANY
LSCI, Inc.
SIGNATURE 1 REGISTERED Y/ N FEE CURREN Y/N
Address 4629 East Bay Dr. 305,Clearwater,FL.33764 License# CVC056656
ELECTRICIAN QOMPANY LSCI, Inc•
SIGNATURE f REGISTERED Y/ N FEE CURREI. LILN
Address 46 5 East Bay Dr.#305,CLearwater,FL.33764 License# EC13001300
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
' I
Address License#
MECHANICAL COMPANY
SIGNATURE: - REGISTERED I Y/ N 'FEE CURREI, Y/N
Address License#
OTHER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N
Address License#
11.11111111111111111111111111111111111111111,Illllllllllllllllllllllli
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsAarge projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)worldng"days after submittal date. Required onsite,Construction Plans,Stormwater'Plans w/Silt Fence installed, .
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the Contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions. '
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner.has hired a contractor or
contractors to undertake work,-they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the '
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'SIOWN ER'S'AFFI DAVIT: I certify that all the information in this application is accurate and that all work
Will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
.compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material-is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THEOWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall Issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety (90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOU NOTICE OF COMMENCEMENI__
FLORIDA JURAT(F.S.117.03) /
OWNER OR AGENT CONTRACTOR
Subscribed and swom to or affirmed before me this Subscribed and swum) r affirmed efore rr�e this
Who is/are personally known to me or has/have produced Who is/are persona known to or has/have produced
as identification. as identification.
Notary Public Notary Public
Commission No. Commission No.
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
4625 EAST BAY DR.STE.305 LSCI, INC, DBA SUN-TEC 7231 HAVERHILL PKWY#201
CLEARWATER,FL 33764. RIVIERA BEACH,FL 33407
727-571-4141 Agreement 877-834-7868
r
Certified Solar Lic.#CVC056656 Certified Electrical Lic.#EC33001300
Purchaser's Names: Date DOB's SSN's
Patricia Priest 5/11/2018 05-24-1970 379-66-3524
William Johnson 01-27-1938 548-50-6257
Address Phone
5329 17th St. Mam'231-499-9959 Alt:
City Zip County Email's
priestpatty@gmail.com
zephyrhills 33542 Pasco lauriejohnson4867@yahoo.com
This agreement and the worksheet agreement(s)attached hereto(the"Agreement"),by and between LSCI,Inc.,a Florida corporation doing
business as Sun-Tec("LSCI"),and the purchaser listed above(the"Purchaser"),specify the terms for the materials to be provided and services
to be performed by LSCI in the residence located at the address listed above(the "Property"). LSCI shall fumish, deliver and arrange for
installation (the "Services") of all materials necessary to improve the Property (the "Products") according to the following specifications,
including all worksheets and forms attached hereto:
Photovoltaic Size: 5310 Series
)7 Financed ❑ COD Deposit$0 Permit$0 Balance$19470 Total$19470
Check No. CC Type CC No. DOE SC No.
LSCI and Purchaser agree as follows:
(1) Serviccs.LSCI shall perform all Services and install all Products in a professional and workmanlike manner,and comply with existing government codes and regulations.All
changes,alterations,or additional demands by Purchaser shall be accomplished pursuant to a change order signed by both parties.Additional Services may require additional
charges,which if in excess of$100,shall be paid by Purchaser at the time of such change.Products or alterations requested by Purchaser subsequent to Products being
specifically ordered by LSCI may require an up charge,such charge due upon the change.
(2) Warran All Products are warranted as per the individual Product manufacturer guidelines for replacement,repair,and manufacturing defects,provided that Purchaser complies
with all manufacturer requirements associated with those warranties.LSCI solely warrants those Services performed by LSCI in installing Products,and all other claims must
be made to the Products'manufacturer(s).
(3) Payment.Purchaser shall pay LSCI for the Products and Services in accordance with the payment schedule attached to this Agreement.Purchaser shall pay LSCI,on demand,
a late fee equal to five percent(5%)of any installment due under this Agreement that is more than 10 days delinquent,and returned checks shall carry an additional fee of Sl00,
due immediately.If any payments due require the use of collection services,Purchaser will be liable for costs of collection,including reasonable attorneys'fees.Title to the
Products will remain with LSCI until all sums due have been paid,and LSCI reserves the right to pick up any Products if payments as set forth herein are not made when due.
Additionally,LSCI can stop work ifpayment as set for herein is not made when due.Except as otherwise stated herein,any deposits are non-refundable.
(4) Risk of Loss for Products.Once Products have been delivered to the Property,it is Purchaser's responsibility to care for them.LSCI bears no responsibly for theft or damage
to Products once such Products have been delivered to the Property.
(5) Liquidated Damages.Purchaser acknowledges and agrees that actual damages for breach ofthis Agreement before commencement of work may be difficult to determine,end
accordingly,Purchaser agrees to pay to LSCI ten percent(10%)of the price stated in this Agreement as liquidated damages for a breach of Agreement by Purchaser occurring
before commencement of Services.Once LSCI furnishes Services or Products under this Agreement,LSCI will be entitled to actual damages,plus 20%,ifPurchaser breaches
this Agreement.Purchaser shall not have to pay liquidated damages if this Agreement is voided by LSCI management or if financing approval is not obtained.
(6) No Liability for Damages.In performing the Services,LSCI bears no responsibility for any water damage,paint damage,framing damage,or any other damage to the Property
unless such damage is the direct result of the gross negligence or willful misconduct of LSCL LSCI will not be held liable for loss or damage,consequential or direct,arising
from the operation or failure of Products,or for work done on existing air conditioning units or components thereof.LSCI shall use reasonable precaution to protect against
any damage to the Property,provided however,that Purchaser shall be responsible for protecting any valuable object or items,or removing such items from the area in which
Scrvic s are being performed.Purchaser agrees that while LSCI is performing Services,Purchaser shall keep the working area free and clear of third parties to avoid any kind
of personal injury.
(7) Authorization of Credit Check.The Purchaser authorizes LSCI to verify and review Purchaser's credit score with an independent credit reporting agency,and releases LSCI
from any inadvertent omissions or errors in obtaining such credit scores.
(8) Permits.By executing this Agreement,Purchaser authorizes LSCI to apply for and sign for permits on Purchaser's behalf.This authorization is only valid for permits obtained
relevant to Services performed pursuant to this Agreement.
(9) Purchasers Right to Cancel.If this Agreement is a home solicitation sale,and Purchaser does not want LSCPs Services or Products,Purchaser may cancel the Agreement in
person,by telegram or by mail.The notice must indicate that Purchaser does not want the Products or Services and must be delivered or postmarked before midnight of the
third business day after execution of this Agreement. If Purchaser cancels this Agreement in accordance with the terms of this paragraph 9,LSCI shall return any deposits
made by Purchaser.
(10) Entire A ment:Except for loan documents executed by the parties in conjunction with this Agreement,the Agreement and the exhibits attached hereto constitute;the entire
understanding of the parties with respect to the subject matter hereof,and no amendment,modification or alteration of the terms hereof shall be binding unless the same be in
writing,dated subsequent to the date hereof and duly approved and executed by each of the parties.
(11) Assignability. Neither this Agreement nor any right or interest hereunder shall be assignable by the Purchaser without LSCPs prior written consent.
(12) Enforceability: If any term or condition of this Agreement shall be invalid or unenforceable to any extent or in any application,then the remainder of this Agreement,and such
term or condition except to such extent or in such application,shall not be affected thereby and each and every term and condition of this Agreement shall be valid and enforced
to the fullest extent and in the broadest application permitted by law.
(13) Binding Effect:This Agreement is not binding on LSCI unless approved and accepted by an officer of LSCI.Upon acceptance by LSCI,each of the provisions and agreements
herein contained shall be binding upon and inure to the benefit of the personal representatives,devisees,heirs,successors,transferees and assigns of the respectii a parties
hereto.
(14) Legal Fees and Costs: if a legal action is initiated by any party to this Agreement against another,arising out of or relating to the alleged performance or non-performance of
any right or obligation established hereunder,or any dispute concerning the same,any and all fees,costs and expenses reasonably incurred by each successful party or his or
its legal counsel in investigating,preparing for,prosecuting,defending against,or providing evidence,producing documents or taking any other action in respect of,such action
shall be paid or reimbursed by the unsuccessful party.
(15) Governing Law:Venue. This Agreement shall be governed in accordance with Florida law. The parties to this Agreement irrevocably and unconditionally consent to the
jurisdiction and venue of the state and Federal courts located in Pinellas County,Florida in connection with any action related to this Agreement.
To perform properly,all Products must be installed pursuant to applicable code,manufacturer's instructions,and within limitations of the building structure.
Under NO circumstances will Product engineering, site specific specifications, warranty requirements, Building Department requirements, installation
requirements,manufacturer tests and recommendations of application/installation be altered.Purchaser shall not have the authority to alter,change,or release
liability from the above requirements for any reason.Should any third party other than LSCI's technicians alter,change,relocate,or damage Products,orportions
of LSCI installed Products,all warranties shall be null and void,and Purchaser bears all responsibility and liability and releases all vendors,suppliers,
manufacturers,engineers,test facilities and LSCI from such liabilities.Verbal understandings and agreements with LSCI representatives are not binding on
LSCI.Any understanding not set forth in this Agreement is not binding on LSCI.
Rep(print)
Donald Shelly Purchaser pairida,pleit'i Date 5/11/2018
(G0%J"Mvu 5/11/2018
LSCI Officer Purchaser Date
` (I A " -kl -,il`ll Izf-t
e13.780-0020 City of Zephyrhills Permit Application Fax-813-7e0-0021
Building Department
Date Received 14DPh
ne Contact for Permitting — -
owners Name' Wilifam'Jolifison Owner Phone Nomher 231 499=9959
owners Address 5324''16TH ST,ZEPHY130 LLS; FL 33542 owner Fhone NDmbar 813-780=61'43
Fee Simple Titleholder Name, . Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 5329-17TH STREET;SEPHYRHILLS, FL`:33542,- - LOT# 13&14
SUBDIVISION PARCELID# 11-26-21-0010-17200-0130
` (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR ADD1ALT = SIGN Q = DEMOLISH
B INSTALL R. _ REPAIR'
PROPOSED USE = SFR = ..,COMM. 0 OTHER' 1
TYPE OF CONSTRUCTION Q. :, BLOCK Q -,,,,FRAME, Q STEEL Q• 'D �Nf�
Install solar photovoltaic System
DESCRIPTION OF WORK t_
BUILDING SIZE SOFOOTAGE� HEIGHT!.. (�
AC
19,370 VALUATION OF TOTAL CONSTRUCTION G '(V
=ELECTRICAL $, AMP SERVICE = PROGRESS ENERGY Q W.R.E;C. Y
100.00
=PLUMBING $;
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA- =YES NO-
. . . . . . . .
LSCI Inc..
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREK., Y/N
Address 46 East Bay Dr.' 305;Clearwater,FL.33764 License# CVC056656
ELECTRICIAN, ,, COMPANY LSCI, II1C.
i.,.
SIGNATURE REGISTERED Y/ N; ,FEE Cl1RREP I Y/N
Address 4675.East-Bay Dr.#305,CLearwater,FL.33764 "License# 'EC13001300'
PLUMBER:c' it COMPANY
SIGNATURE REGISTERED I 'Y/-N', FEE'CURREn 1 Y/N'
Address. License#
MECHANICAL "II(� COMPANY'
SIGNATURE'S h f ., REGISTERED :Y/ Nr, +-FEE CURREn`l Y L N
Address J License#
OTHER". COMPANY
SIGNATURE REGISTERED 1.Y/.N FEE CURREn Y/N
Address _ - License#
I111,1Ir111.11,1.,1',1',1.11,1'1,1`11.1�11.1;1,1,1.1,1.1_1'1.11;1_,11,LI_I li.L,1,1.:11-.111111111,1_�LL11;1,.1111 ,
RESIDENTIAL Attarih(2)Plot Plens;(2)""sets ui Buflding.Plans;(1)set of Erieigy Fonns;,R=O-W Pertni►.for new construction,
Minimum ten(10)inoikinb days aftet isutimittal date: Required onsite;ConiStrUC1ion Pians,Stornweter Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsAarge projects
COMMERCIAL Attach(3)complete sets of Building Plans plus a life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction., ,
-Minimum ten(10)working-days,after submittal date. Required onsite,Construction Plans,Stonmwater Plans w/Silt Fance installed, r
Sanitary Facilities&'I'dumpster.Site Work Peirnit for al(new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets bt:Engineered Plans. -
""PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2600,a Notice of Commencement Is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (Front of Application Only)
Rereofs V shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
1�
Was, k Willh
\t3
j
C
I�� I IIIIII Illll Illl{fill{III1{IIIII IIIII III{I IIIII Illil IIII IIII
2018141475
- I
-0 ?j Rcpt:1983937 Rec: 10.100
Permit Number DS: 0.00 IT: 0.00 i
Parcel ID Number 11-26.21-0010-17200.0130 08/21/2018 L. K. , Duty Clerk
NOTICE OF COMMENCEMENT PAULA S.O'NEIL,Ph.D.PASCO CLERKI & COMPTROLLER
-State Florida 08RiBK018i0iam ACount of O 9775PG
43
THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the
Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT.
1.Description of property(legal description): CITY OF ZEPHYRHILLS PB 1 PG 54 LOTS 13&14 BLOCK 172 OR 3612 PG 1695
a)Street(job)Address: 5329 17TH STREET ZEPHYRHILLS,FL 33542
2-General description of improvements: INSTALL SOLAR PHOTOVOLTAIC SYSTEM
3.Owner Information or Lessee information if the Lessee contracted for the improvement:
a)Name and address: WILLIAM O.&LAURIE L.JOHNSON 5324 16TH STREET ZEPHYRHILLS,FL 33542-5060
b)Name and address of fee simple titleholder(if different than Owner listed above) ------------------- r__�
c)Interest in property: ----------------------------- _.__________r_____�_�-_ _—___ _—__
4.Contractor Information
a)Name and address: LSCI INC. 4625 East Bay Drive#305,Clearwater, FL 33764
b)Telephone No.: 727-571-4141 Fax No.:(optional) 727-683-9854
5.Surety(if applicable,a copy of the payment bond is attached)
a)Name and address: N/A
b)Telephone No.: N/A
c)Amount of Bond: $WA
6.Lender
a)Name and address: N/A
b)Telephone No.: N/A
7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section
713.13(1)(a)7.,Florida Statutes:
a)Name and address: N/A
b)Telephone No.: N/A Fax No.:(optional) N/A
8.a.ln addition to himself or herself,Owner designates N/A of N/A
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
b)Phone Number of Person or entity designated by Owner: N/A
9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be..1 year from the date of recording.unless a different date is specified): ; ,20
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE
CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART I,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON
THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN
ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, j
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my
knowledge j�ndJ.belie
('V WILLIAM O.JOHNSON
(Signature of Owner or Lessee, ers or Lessee's(Authorized OrticerlDirectorlPartner/Manager) (Print Name and Provide Signatory's Title/Office)
The foregoing instrument was cknowledged before me this day of _7 f-3 / g '20 f
by WILLIAM O.JOHNSON ag HOMEOWNER (type of authority,e.g,officer,trustee,attorney in fact)
for ++++++++++++++++++++++++++++++++++++++++++ ,
,as ++++++++++++++++++++++++++++++++++++++.
(Name of Person) (type of a ority,...e.g.officer,trustee,attomey in.fact)
for +++++++++++++++++++++++++++++++++++++++++ (name of party n behalf of wh m instrument was executed).
Personally Known ❑ Produced ID ❑✓ 4
Type o,,Jill I) Notary Signatur
`O�pRY.P el
U6�i tyt Ulf Print nameC��t
COMMISSION # FF191670
*' *` EXPIRES:January 21,2019
=sr•. oQc
%', OF,Flci��.� www•AARONNOTARY.COM
\
`
. .
STATE OF FLOMIDA,COUNTY OF RAGC0
THIS|STJCEROFY THAT THE FOREGOING |SA
TRUE AND CORRECT COPY UF THE DOCUMENT
{]N FILE OROF PUBLIC RECORD |N THIS OFFICE
O
PEE IIIUH
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received:
Site: 7i� A�
Permit Type: `�v -� 2 !ems
Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
y-p/1
Kalvin Swi /- 1 �Examiner Date Contractor and/or Homeowner
(Required when comments are present)
RSTC Enterprises Inc
2214 Heimstead Road
Eau Claire, WI 54703 S U LA D ECK
715-830-9997 ���. :
Outdoor PASS thru enclosure: Model - 0786-313 5
Asphalt/Cedar Roof Systems
For AC or DC current -
ETL Listed and labeled to UL standards `
Report#3125796 CRT-001 b Revised March 2012
• UL50 Type 3R, 11 Edition Electrical
equipment enclosures n
• CSA C22.2 #94-M91 special purpose °
enclosures (2006) °
i
Basic specifications
Material- 18 Gauge G 90 Steel Base/Cover ,
Process- Seamless draw(stamped)
Flashing- 15"x 15"
Height- 2.625" `
Cavity- 8" x 9"x 2.5" (162 Cubic inches)
Finish- Powder coat(1100 hours salt spray) 'r..
t SO�AQECK O'78B-3R5
Assembly:
* Cavity Base and cover punched for matched assembly
• Base Flashing pre-punched for roof deck mounting -
• Cavity Base- (5)predetermined dimples v_
for fittings or conduit S= --- - �°--'--
.'�nuwn 2 Circuit AC Pry.:a?'h ru
Base plate: .:=: -
16 gauge galvanized steel
* Fastened to base flashing with toggle fastening system '
• Finish- Powder coat(1100 hours salt spray)
• (5)Roof deck knockouts
• Knockout sizes-(3).5",(1).75"and(1)1"
• Rail-7"slotted 35mm
Ground-Installed with steel stud and star nut i
(5)Position for wire size 14-6 ?
Strain Relief Clip-Aluminum riveted installation
Hardware pack: .
7-1°'Truss head screws ' u
4-.5 8-32 thread cutting screws —- -
4-Bonded seal washers#10
2-10-32%" Steel studs
2-Foam
3/8" steel star nuts With 2 circuit AC ass thru kit
1 -Faam gasket sea! p
1 -Installation instructions Kit Part # 01612
*** Kit sold separately
E Mount I QMSE i
Elevated Water Seal Technology@
THIS EDGE TOWARDS ROOF RIDGE ITEM NO. DESCRIPTION QTY.
1 FLASHING,ROUNDED CORNERS, 9"X 12"X 1
.040",5052,MILL
2 QBLOCK,CLASSIC,A360 CAST AL,MILL 1
3 HANGER BOLT,PLAIN CENTER,5/16"x 6", 1
18-8 SS
4 WASHER,SEALING, 5/16"ID X 3/4"OD, 1
EPDM BONDED SS
RACKING COMPONENTS 5 NUT,HEX,5/16-18,UNC-2B, 18-8 SS 2
NOT INCLUDED 6 WASHER,FLAT,19/64"ID x 7/8"OD x 1/8" 1
EPDM
5 7 WASHER,FENDER,5/16"ID X 1"OD,18-8 SS 1
12.00 8 8 WAS
F� i' HER,SPLIT-LOCK,5/16"ID,18-8 SS 1
I
fjl ; 6
7 t '
I
o I
_ I
1.50 5
3.00 4
3
4.50
9.00
2.50 2
1
1.29
4 - Quick Mount-PV
�- TITLE:
QMSE: QMPV E-MOUNT
T-
(3.00) (3.87) AVAILABLE IN MILL,AND
BLACK FINISHES. UNLESS OTHERWISE SPECIFIED:
_ SIZE DRAWN BY: RAD "- REV
_ - IF
DIMENSIONS ARE RJ INCHES
TOLERANCES:
.... A DATE: 5/9/2017 4
.. FRACTIONAL:I/9
NENFRARI'ANDCONflDENMI TWOPLACEDECIMAL !.19 - - - - -' '--- -- --"---------
MEMFORM1110NCOMAWEONfH6DRAtY1NG GTNESOLEPROPERTYOFONCKMOUM PV.ANY REPROWOTIONWPART OR ASAWNOLEWIMOUfTHE DO NOT SCALE DRAWING THREE DECIMAL_.09C SCALEI:3 WEIGHi:0.9172 SHEETI OFI
v,'RIffEN PERMISSIONOFOUIUMOUMPVGPROH®RED. COPYRIGHT 02016 QUICK MOUNT PV ,
5 4 3 2 1
Lag• • • •. •s)in typical luinber:
Lag Bolt Specifications
Specific Gravity 5/16"shaft per 3"thread depth 5116"shaft per 1"thread depth
Douglas Fir,Larch .50 798 266
Douglas Fir,South .46 705 235
Engelmann Spruce,Lodgepole Pine(MSR 1650 f&higher) .46 705 235
Hem,Fir .43 636 212
Hem,Fir(North) .46 705 235
Southern Pine .55 921 307
Spruce,Pine,Fir .42 615 205
Spruce,Pine,Fir(E of 2 million psi and higher grades of MSR and MEL) .50 798 266
Sources:American Wood Council,NDS 2005,Table 11.2 A,11.3.2 A
Notes:
1)Thread must be embedded in a rafter or other structural roof member.
2)See NDSTable 11.5.1 C for required edge distances.
quick Mount o
RESPECT T.HE ROOF
BI 7.2.3-26 May-2017 Rev 6
^
. � ��o�UD�� U���UU������ U�w�����o���
Q��8������xxU �nu��U��U��wUU��uo Unx��Kn����8U��uon�
Installation Tools Required:tape measure,roofing bar,chalk line,stud finder,caulking gun,sealant compatible with roofing materials,
drill with 7/32"long-style bit,drill or impact gun with 1/Z"deep socket.
De Tsel
11, co
Istcoarse
Locate,choose,and mark centers of rafters mbe Carefully lift composition roof shingle with roofing Insert flashing between 1st and 2ndcourse.Slide
mounted. Select the courses of shingles where bar,just above placement of mount.Remove nails vpso top edge vf flashing|sat least s/4^ higher
mounts will beplaced. as required. See "Proper Flashing Placement" un than the butt-edge of the and course and lower
next page. flashing edge i,above the butt-edge of1stcourse.
Mark center for drilling.
cow
rse
7,-7 A
"p,
Using drill with 7Gu^bit,drill pilot hole into roof Clean off any sawdust,and fill hole with sealant Slide flashing into position. prepare hanger bolt
and rafter,taking care»o drill square tn the roof. compatible with roofing materials. with hex nut and sealing washer. Insert into hole
oo not use mount asa drill guide.Drill should be and drive hanger bolt until Qa|ock stops rotating
'long style bit,aka'aircmft extension bit'*o drill u easily.oo NOT over mp,qua
u^deep hole into rafter.
|nertEpDM rubber washer over hanger bolt into Using the rack kit hardware, secure the racking
block. (L-foot) to the mount using torque specs from
racking manufacturer.|f racking manufacturer does
not specify torque setting,tighten to13ft.'|bs.
8|7.u.a'uo mayan77 Rev o
Reference and Tips `
Proper Flashing Placement
Additional tips and information for installing mounts:
® See Quick Tips videos on nail removal,bolt prep,and more at:
http://www.quickmountpv.com/support/videos.htmi
® It is not necessary or advisable to use nails or other fasteners to secure the perimeter of
the flashing.
■ The E-Mount is made to work with standard and high-definition composition/asphalt and wood
shingle roofs with 5"to 5-5/8"courses. If the exposed surface of the course exceeds this measure-
ment you may need to use our Classic Shake Mount instead.
■ Depending on the season and climate,size and location of seal tabs,and quality of the shingles,
the seal tabs that adhere the shingle courses together may not effectively seal the shingles to the
fleshings.If this is the case,simply add several quarter-sized dabs of manufacturer accepted sealant
or asphalt roofing cement,meeting ASTM D 4586 Type II,between the flashing and the shingle
above.
■ Mounts should not be installed in areas of the roof susceptible to ice damming.Water ponding un-.
der the shingles can reach the bolt penetration.
® Take care not to damage the roofing material while working on the roof. Removing stone granules
and deforming the shingles in any way can shorten the lifespan of the roofing.The value of the solar
array is directly affected by the condition of the roof it is attached to.
BI 7.2.3-26 May-2017 Rev 6
I
' I
i
i
Guick Mount PY"D
RESPECT THE ROOF
925-478-8269 1 www.quickmountpvcom I info@quickmountpv.com
2700 Mitchell Dr. I Walnut Creek,CA 94598
O 2017 by Quick Mount PV.All rights reserved.
AL
IC"
celS' eftlng- the'��ndarcf* MATA
33 (
)() GRADE
PROFESSIONAL
POLYURETHANE
1. PRODUCT NAME: Grade:Gun grade consistency
33000)Professional Primer,Not required on most
Grade Polyurethane Sealant surfaces
2. MANUFACTURER- Packaging: 10.1 fl,oz.cartridges
Geocel Products Group Colors:White,gray, limestone,
A Business Unit:of bronze,medium bronze,tarn,
The Sherwin-Williams Company aluminum gray,black,and
("Geocel Products Group") redwood tan
Cleveland,OH 44115 Application Standards: Meets
Phone:(800)348-7615 ASTM C 920 Type S,Grade NS,Class
Fax:(800)348-7009 25,Use NT,A,M,G,and O;Meets
wsvw.GeocelUSA.com a t Federal Specification TT-S-0230 C,
Type 11.Class A;Meets Canadian
3. PRODUCT DESCRIPTION; Specification CAN/CGSB-19.13-M87
33009)Professional Grade Class 2 Non-sag,Class 25,Class M.
Polyurethane Sealant is a single � t! Limitations:
component,high performance y }: �;r-
polyurethane sealant that withstands *fir ssto:a:l Do not apply over damp or
extreme weather conditions and cures ^teuaEritAns contaminated surfaces
to a flexible weatherproof seat. �oonn or F a Do not apply to absorptive
��ca,¢"ra ems? surfaces such as marble,
Product Benefits: ,a��,lo�=fig, limestone,or granite without prior
a Withstands extreme weather conditions ' Pe¢rnWrt7
a Meets ASTM C 920 testing for discoloration or staining
e Moisture cure
Flexible +w� 4. INSTALLATiON:
a Minimal shrinkage ' a Joint Design:The width of the joint
a Non-sag formula r should be a minimum of 4 times the
a Primerless adhesion on most surfaces anticipated movement.In joints up to
Paintable,non corrosive 1/2"wide,the depth of the sealant
.Contains no TDI(toluene diisocyanate) should be equal to the width,but not
-� .. less than 1/4".In joints wider than
Basic Uses:3300 Sealant can be 1/2",the depth should be maintained
used in roofing applications such as at 5/8".Lap shear joints should have a
concrete roofing tile,clay roofing tile, ; width of at least twice the anticipated
metal roofing,Kynar 50N,coated movement.
metal.and composition shingles. _; Surface Preparation:Joints to
Other applications include building receive sealant must be sound,
lath paper repair,gutters,HVAC, Adheres To:Masonry,ceramics,wood, smooth,uniform in dimensions,and
flashing,skylights,roofing seams, steel,Kynar 500",aluminum,asphalt free from defects and foreign material.
roofing projections,termination shingles,building paper,BUR,concrete, They must be clean,dry,and free of
points,and vents. fiberglass,and other common building frost and all contaminants,such as
substrates. curing compounds,sealers
(waterproofing),coatings,etc.Sealant
FIGURE 9 FIGURE 2 FIGURE 3 POLYME-niAiNE v
Proper Depth control Joints without Bond Breaker Joints with Bond Breaker SILICONE T�T i ®I •
The effects on the sealant with and without bond breakers are illustrated In Figures Two and Three.
Kynar 500'is a registered trademark of Arkema Inc.
~
' adhesion should be tested oneach VAPOR/PARTICULATE RESPIRATT}R fmUun* and as your sole remedy,we
� different caulking. MAY BE EFFECTIVE.Follow directions will either
tept adhesion,apply a sealant bead for rthemop�ah��x refund the
and allow h || the
'u�bmou�i|all vu gone. price fn originalpurchase
of product that
�
one end of the be ad to test adhesive If^ ^ fails' - ' ''-- ^'-------- --
ohang - mwxg use,LEAVE THE AREA and get this limited Labor uoo�
Joint Backing;Joint kenka� U associated ' are not
exceed B8^.Ao open mA|backer md | IMMEDIATELYoeU doctor � included.THIS LIMITED
should be used tocontm|joint dapth � ovoi|oU| ��emergency medical ' -'-''-
' ~ ~ '~» ' ~~ WARRANTY|G|N LIEU OFALL
In shallow bond treatment./---'- OTHER EXPRESS
should bem�o}�dtOpn�en h '
three-point contact, sandingroznu�nc �e'dried film.|f OR IMPLIED,INCLUDING
adequate en�\�k� cannot provided K4ERCHANTA8\LO`(VVH|CHARE
Elongation: ° ventilation '' p'",
'
laokFrge wear~ approved,~~~~~^~respirator ALL 0|GCb\|K�EDANDX}R
' ''(N|O8Ha Follow respirator LIMITED|N DURATION TOTHE
Cure:1day manufacturer's directions for respirator EXTENT PERMITTED 8Y LAW.VVE
Service Temperature: use.IRRITATES SKIN AND EYES.Avoid SHALL NOT BE LIABLE FOR
'20~Fho150^F(-29^Cto88"() contact with eyes and skin. |n case of INDIRECT,SPECIAL,INCIDENTAL
Application Temperature:
contact, himmm��e/ywidh OR CONSEQUENTIAL DAMAGES
` ~! � for-200Fto 15O"F�28^CtoG8"{) p�'� ,""`� (INCLUDING LOST PROFITS)
''
and call a doctor'K not available get FROM ANY CAUSE WHATSOEVER
Application and Tooling:Apply with emergency medical treatment.|n case of AND SUCH DAMAGES ARE
conventional caulking equpmem m| skin contact,wash thoroughly with soap EXPRESSLY EXCLUDED. Some
joints from the back to prevent voids and water.Clothes contaminated bya states do not allow the exclusion or
and air pockets. |fapplication spill should bo removed and laundered. limitation of incidental o/
temperature is below 400r Keep container closed when not|nuse. consequentiald how long
precautionsshould oe taken noensure Reacts with water in closed container to on implied warranty lasts,aothe
the substrates ieto| dry and produce pressure which may cause above limitation or exclusion may
frost free.Immediately after application, container to burst. Do not transfer not apply to you.This limited
tooling ia recommended 0m ensure firm, contents to other containers for storage. warranty gives you specific|egal
full contact with the joint sides. First Aid:\n case of eye contact,flush rights,and You may also have other
Cleaning:Remove 33OO Sealant from thoroughly with large amounts of water. rights which vary from state 0o
gun and tools before/tcures.This may Get medical attention/rirritation ~^~`~'
be done by scraping and use of persists.If swallowed,call Poison
solvents such as ?. K8/\\NTENA0C���
menufa��um/ninoUouUonsfor o�e immediately. ' |f sealant|o damaged and the bond
use.Cured materials may baremoved DELAYED EFFECTS FROM LONG io intact,cut out the damaged area
by cutting with sharp tools or TERM OVEREXPOSURE.Abrading o« and euau|k.Nu primer imrequired.
sandpapering. sanding of the dry film may release |f the bond has been affected.
Storage and Shelf Life:Unopened crystalline silica which has been shown remove the sealant,clean and
containers should be protectedhnm ho cause long damage and cancer under A�pmethe iointinaccordance
heat,nmiotue.and d� �aun. Dun<� long term nxpooum. with the ina�u��innaunder
opeoontoinaround|all'—preparatoryWarning:This product contains "Surface Pmpanabnn."and nonmu|k.
work has been completed. Material in chemicals known to the state of 8 T�[�8N|�/�LSERV|C��'
unopened containers Californiaocauoenao��andbi�h ' `
�
to1 year when stored at75"F(l5"C), defects or other reproductive 'herm DO
Geocel Products Group
throughoutth�US
Cautions: CONTAINS NOT representativesU.S.
' /
ALiPHAJ\CPOLY|8QCYANAJE THE REACH OFCH|LDREN� are available to provide techni
cal
uaoiatance��eoce|�mduuts
HEX4WYETHYLENE0|9OCYANAJE. Qmu �inhouae�chnica|s�ff
AROk�AT|OPDLY|GDCYANAJE � Ah��L48|UTy/�N��{����� and|'bou�my�«|�io»�*
POLY�NETHYLENEP(]LYPHENYL - �
°^ AVAILABILITY~~'`~ ~~~'` aq�ppodto respond hnspecific
|GUCYANAJE./NETHYLENED|PHENYL Available hnm various lumber yards, requests for further information
D||9OCYANATE.CRYSTALLINE SILICA hardware stores,home centers, and/or applications testing-
VAPOR HARW1FULQiveaoffharnful construction � h�onm � undindusthal
vapor of solvents and isu na1 DO distributors.Cost and further
NOT USE|F YOU HAVE CHRONIC technical data are available from your n|FDx[l/[ALn[Ln
(LONG-TERM)LUNG ORBREATHING local Gonon|Products Group n''1»'1«.oz.Cartridge
PROBLEMS,uM/F YOU HAVE EVER representative Joint Size UneurFeeL
HADARE/KCT|ONT]|SOCYANATEG.� ' 1/4^x1A" 24./
USE ONLY WITH ADEQUATE 1M^x80" 16.0
VENTILATION.A POSITIVE PRESSURE 6. LIMITED WARRANTY- 1/4"x1/2" 1D.0
AIR SUPPLIED RESPIRATOR 0NIOSH |f when applied according bolabel 1/2''«3/8" 8'4
112"x1/2^ UU
. dSHOULD BEVVDRNTO dimn1|onothis pmduotfails to 3/4"x1x2' 4-
'~
PREVENT EXPOSURE.\F perform in accordance with its
UNAVAILABLE,ANAPPROPRIATE published literature,upon For additional product information,
PROPERLY.FITTED.APPROVED N0GH satisfactory /e�'m the P«»d«C/Spec u//ee/
located at wwmGnoce/USA.00m.
Cleveland,ux441`o
Geocel m00>u*8-7ms~Fax m»mm+/00»
`,: 1 1 SOLAR
STANDARD SYSTEM GROUNDING '
wool 1
= SM MOUNT INSTALLATION GUIDE PAGE
---------------------------------------=---=-------------------------------------------------------------------------7-----------------------
, E/,s Ei?LILC
�- i singte Use 4 Only
nsYai[C,nduCftsr and
terpe to the fot[n_`.ving:
( - i 6-14 AMA:sfi-Ib=
r
-ONE Lk1G,PER OF MODULES:` ,:::,'..' :--'•''' `iu ' . r t ;
l •: WEEBLUG CONDUCTOR-UNIRAC P/N 008002S:
-:.•,;Only one^lug_p of'modu.le's,,is u r
Apply Anti Seize and insert a bolt in the aluminum rail and through the clearance
ram, ee-Page or additl t lu ep ired-for:, hole in the stainless steel flat washer. Place the stainless steel flat washer on the bolt
on joints. •' '"` G 'S �,
i oriented so the dimples will contact the aluminum rail.Place the lug portion on the
bolt and stainless steel flat washer.Install stainless steel flat washer,Lock washer and
nuf.Ti hten the nut until the dimples are completely embedded into the rail and,lug. .
9 P P y
- f=
OROUE >ALIUE 1 tbs. SeG i�'ote oil i'=�.t�`
I• %� .a"r. rF "4:mcre deaiLS Model Ao. aVEEi^LUG-6uwt aaY�Si2�% �___.. . o prfd
GROUNDING LUG MOUNTING DETAILS: tzr'Nzsher i, �I N��
Details are provided for both-the WEEB and Ilsco products.The WEEBLug has a s;„g;:e use Only, ;
grounding symbol located on the tug assembly.The Itsco tug has.a green colored'
set screw for grounding indication purposes.Installation must be in accordance 00. '"
with NFPA NEC 70,however the electrical designer of record should refer to the r`
latest revision of NEC for actual grounding conductor cable size. TIMMINALTORQUF,
Instats coklductor and
aSef uiz ee.if no",{using approved integratel grounding ralcrauiriveters tc r�itr ec,I�>3 fo[3 'y sicn:- .
4 6 A VG:Sain-lLs
GRQUND_I_NG LtIG $OLT'SIZE&iDRIEVSIZE;
._ ILSCO LAY-IN LUG CONDUCTOR-UNIRAC P/N 008009P:Alternate Grounding Lug
GROUND LUG BOLT SIZE DRILL SIZE -Drill,deburr hole and bolt thru both rail walls per table.
WEEBL.ug 1/4" N/A-Place in Top SM Rail Rot i01Rli}C Li,}E.jfflbs.(s �itiot nPv.f}
IkSCO Lug #10-32 7/32". Se ii SOD product data sheet for more.&tail=,Modet Wo.Gf, -4DB is
* Torque value depends an conductor size. NOTE:ISOLATE COPPER FROM ALUMINUM CONTACTTO PREVENT CORROSION
• See product data sheet for torque value. _
RUG-14-2018(TUE) 11: 12 Home Improvement 5ervices (FAX)727 540 0804 P. 001/001
. Ilftflllllllfffll�flll�lf(llllllllllllllll(ljlllll�l�lllgi
xaxslls�s3s �
Rcp 1970287 Re6: 16.00
�; bb D5: 0.013 IT: 0,2l0
i tNumber `"{ v 07/02/-21118 K. K., DPW Clerk
Parcel 10 Number 4626 ,!-fiC�/b�7 Lt!-bI Q rAULA 6,O'NUL,Ph.0.P .o'Ci.ERK a CpQMPMOLLER .
NOTICE OF COMMENCEMENT '07/02/2018 09: 7am 1 of Ii
State of Florida OR BK 9749 PG 3641
County of Pinellas
VE'UNDERSIGNED hereby gh►es notice ft'h pravaments will be made to mrWn real property,acid in ammdance wilh Section 71&13 of the
Flodit StatlrK the fallowing hbm*n is parMed in this NOTICE OF COMMENCEI 01T.
9.DeilalPlion of proPMy(k9d desalp0m): G..E�( M9_/T it'dd aL,,O M/V eA4 172 bra. Ag &9.�_
a)Street(jab)Addr= 5'9 ..._ ,% LSr -S0 .r_ .�. ...�.
LGeneral description of lmpmvammdw.
3.0 mw IdWroatlon or I asseo lukn dffl If the lessee contracted for the IMrry MOft
a)Name and address: iW
ftt Igtr�t.i �
b)Name and address of fee simple ihtehotder(if tiftW ttte,►t Owner listed above)
,q)1"West in property.
4.Cor4metor Infoamtlan
a)Name and addt+es tst:l,lnc.4ti25 East&y Dr„Sto.306a.Ctgrolurater,FL 3;i764
b)Telephone Nos 727-art-4141 Fax No.:(optional) 727-saa-08M
SSwaty Of applicable,.a Copy otthe payment bond is as dmo
a)Name and address: ' _ ,�„,�,, •�4 .___.„_ � ._,.e
Ca)Telephone Nos ,,.• ,�,
a)Amount of Braid: i __ ...... `
a)name and address`
b)Telephone No.:
7.Persons within the State o(Florida4e94ttated by Owner upon whom notices or u_&er der m=ts may be served as pmvlded by Section
713.13(1)(a)7.,Floiula'Standw —
a)Name arrd add`=.
b)Telephone No.: _ __ Fax Na:(optional)
Lain addition to' hhnseNorh�etssN,GnArner dalgo"
to mceJve a copy of the Uemes Ndw as provided in Se*n 713,13(1)(b),Fbrtda Sffitu
b)Phane Number of Person or entity designated by Owner
9.E,xpWan data of notice of commencement(the molafmn date may not be before Ilse aotnpMm of consbudlon and final ppymerd to the .
conholor,WWI be 1 yearfrom the date of meardin urks a dtiferentdate iswqroi'isd): j ,2D "
WARNING TO OWNER:ANY PAYMEM WE BY 711E.01NNER AKER THE EXPIRATION OF THE NOTICE OF COIL B CE M ARE
MSIDERW MPPROP911 PAYMENT$`Utr M OWY ER 713,PART 4 SECTION 71&13,FLORIDA STATUTES,AND CAN RESULT IN YOUR
PAYING TWICE FOR IMPROVEMIKIS TO YOUR PROPER11Y.A NOTICE.OF COMRMNCQVI W MUST BE RtcC mom AND POSTED ON
ZHE JOB SITE 0WORR THE FIRST INSPECTION.IF YOU INTEND TO OBTAIN FINANCING;CONSULT WITH YOUR l UNDER OR.AN
ATICIRIW WORE COMMENCING WORK OR RECORDING YOUR NOTICE OF CO MENCt .
under pa"or"",tociere i eOt!11re i�egoing rlotire of cornnsettcemerd and that the tb41S meted ttiereln are true to the bit9t—my
er�d
r
' o�/lin5a �
tsiorasMa t Ww�arar or arLeasee's(Audrortarrd CID �2004
The foregairrg insbun>ent gad bcge me tftS �'� day of �� -rby .Ji �A,rr �Tuas adnC,,G. t�ypadMAWRY,a:p.amr.tmtm a is omiiln Ace
• fpr :.., .__,,.,. 'as .. . t�� orrgr,...o�.afticet,fn�stee,athimay tr,lacq . .
for ....' (name alp •on ttetelf of hssautnent was ammded). i
Personally ICnoam, Q Pmduced ID
Type of ID G Notary Signature
�I�b�f� GiCOV� Prhttname
_ ,
COMMIS960 # FF1910
N'.. EXPIRES:January 21,2019.
�• gt„ www.AARONNOTARYAM
so I a I " - Single Phase Inverters for North America
' ! SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ I F1y� �+
SE7600A-US/SE1000OA-US/SE11400A-US
si€um-us sE3 -us sesooa -us SE6000A-US SE760oA-us SE 10000A-US SE -US
9980 @ 208v $ '
Nominal AC Power Output 3000 3800 5000 6000 7600 11400 VA
...................................... ................ ............... ................. ................ ................ .1 0240V. ,
Max.AC Power Output 3300 4150 6000 8350 12000 VA
5450 24dV 14950 240V •� v
G?....... ................ ................ .........C?....... ................ _
AC Output Voltage Min:Nom:Maxi'I ✓ ✓ �Er d
183 208 229 Vac ............. ........ ...... ......... ...... ...... �•, a a
AC Output Voltage Min:Nom:Max.i'i o $. - $ s
211-240 264 Vac € q
AC Frequency Min:Nom.-Max.l'i 59.3 60.60.5 Hz p o` $
Max.Continuous Output Current 12.5 16 24 @ 208V 25 32 48 @ 208V 47.5 A o a g A s
........................................... ................ .............. .....�......... .....--......... ............... .....@...... .................. ........... c ''. E ' : '�• i
GFDI Threshold 1 A
....................................I. ....,..,,,.........,.,..,,..,.............,..................................................................., W m a x a ' �'
Utility Monitoring,islanding Protection,Country Confurabie Thresholds Yes Yes o $ p
Maximum DCPower(STC) 4050 5100 6750 8100 10250 13500 15350 W - g a os n $
......... .... .................... .....4050..... .............. ........ ,................. ...........0_.. ...........
.m.
Transformer less Ungrounded Yes d
Max.Input Voltage 500 Vdc �� _ A
........................................... .. ..... ......
Nom.DC Input Voltage 325@208V/350@240V Vdc •
........................... . .-...... .................. .,................ ...........
16.5 @ 208V
Max Input Curren 9.5 1 13 f 18 23 34.5 Adc :•4
1...:...........1.15 5. .240V. ................ . ..30 5 @ 240V..I............-..... ....-...... _ '. e: 5
MaxInput Short Circuit Current 45 Adc w : a................................... .......................................................................................................................... ...........
£ r• K
Reverse Polarity Protection Yes E : : a: � g ff
................................. .......................................................................................................................... ........... E.X a. =:
Ground Fault Isolation Detection 6001cu Sensitivity a 3 �: 8
aaaaa• :3dE �_� 4 sw : :X:Li : r
.. ............................... ......-......- ..-................ .................. ........-.. i g Ec y Q : c E`3: `d: E E E :� .y yg
Maximum Inverter Efficiency . .97.7 98,2 98.3 97@208V
............. . -----............ ................ ................ .................. .-,.......---....
97 @ 208V !� u € 4
CEC Wegfited Efficiency 97.5 98 97.5 97.5 97.5 V+%
.. ...:..... ..48 Q,240V.. ••.,............ .,.............. ..97S @ 240V. ................. . a.
Nighttime Power Consumption <2.5 _ I_<4 W
Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee al)
................•-........................ ..... ......................I.. (option............................ ............ ...........
Revenue Grade Data,ANSI C12.20 Optionali'i
Rapid Shutdown—NEC 2014 690.12 Yes
Safety .yUL1741L1741 SA,ULU8 CSA22.2 .............. ........ ........... \. . .
Grid Connection StandardsIEEE1547............ ............................................... ...........
Emissions FCC part15 class B }
AC output conduit size/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG
—. ................................ ....................
DC input conduit size/8 of strings/ 3/4"minimum/1-2 strings/16 6 AWG 3/4"minimum/1-3 strings/ _ g
AWG,ran$?............. . ............. ........ 14-6 AWG
........-3/4 --......-. .1.-. .s.tri .....1 ............................. .......--....--.,................... .
Dimensions with Safety Switch 30.5 x 12.5 x 10.5/ in/
30.5x12.5x7.2/775x315x1g4
(HxWxDj J75 x 315 x 260 mm
Weight with Safety Switch............. ..........51.2/23:x..........1...................54.7124: .. ...........
.. .. 88:4/40:l............ .lb
Natural
convection
Cooling Natural Convection and internal Fans(user replaceable)
fan(user
......................................... ....... .replaceable) .......................................... ...
.
Noise ......................................................
............................ .
Min.-Max.Operating Temperature r+l d C
Ran a -13 to+1401-25 to+60(-40 to+60 version available ) F/'C N a)•
.. . . .E
..........Rating NEMA 3R �. . .� Q it
.........I ..I... .......... ......................................................................... ,..--.--................ ................. .
lu For other regional settings please contact SolarEdge support. L O
A higher current source may be used;the inverter will limn its input current to the values stated.
Revenue grade inverter P/N:SEmaA-USOOONNQ. O O
re-40 version P/N:SEmaA-US000NNU4(for 7600W inverter.SE7600A-)S002NNU4).
U-
o a
-m .
L
11W "" i C m a
0 0
y
Z-104
Format 65.7in x 39.4in x 1.26in(including frame)
�-'•— (1670mm x 1000mm x 32mm)
Weigh 41.451bs(18.8kpJ ••m.ear+ranrxc..
Front Cover 0.13 in(3.2mm)
41 thermally pre-stressed glass with anti-reflection technologyr--
Back Cover Composite film
Frame Black anodized aluminum -.
Cell 6 x 10 Q.ANTUM ULTRA monocrystalline solar cells
Junction box 2.60-3.03 in x 4.37-3.54 in x 0.59-0.75in(66-77 mm x 111-90 mm x
15-19 mm),Protection class IP67,with bypass diodes •=w.•..
'. , • , , Cable 4 mm'Solar cable;(+)139.37 in(1000mm),()≥39.37 in(1000mm) ..a•
-I I-,.r n .
Connector Multi-Contact MC4 or MC4 internateable,1P68 ,,,., T�I•,:n•.
MINIMUM PERFORMANCE AT STANDARD TEST CONDmONS.STC'(POWER TOLERANCE+5W!-OW)
Power at MPP' - P„,. LW] 290 295 300
Short Circuit current* I,° [A] 9.63 9.70 9.77
With its top performance and completely black design the new E Open Circuit Voltage* V„ IV] 39.19 39.48 39.76
Q.PEAK BLK-G4.1 is the ideal solution for all residential rooftop applications Current at MPP* I_ (A] 9.07 9.17 9.26
-----
thanks to its innovative cell technology Q.ANTUM ULTRA.The world-record Voltage at MPP* Y,a, m 31.96 32.19 32.41
EtRclerl
cell design was developed to achieve the best performance under real con- [%] __. Z 17.4 Z 17 7 z 18.0
MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS,NOW
ditions—even with low radiation intensity and on clear, hot summer days. Power at MPP' P,a, [W] 214.4 218.1 221.8
Short Circuit Current° I (A] 7.77 7.82 8
LOWELEHigher yield per surface area2ndsTOWer BOS costs thanks to Open Circuit Voltage*- Vw IV] 36.65 36.92 37.19
8
GCurrent at MPP
Ira* W 7.12 7.20 7.27
higher power classes and an efficiency rate of up to 18.3%. Voltage at MPP* v„ Iv] 30.12 30.30 30.49
'1000 W/mo,25'C,spectrum AM 1_50 'Meanurement tolerances STC x3%;NOC x5% '800 W/m0,NOCT,spectrum AM 1.50 typical values,actual values may differ
INNOVATIVE ALL-WEATHER TECHNOLOGY
Optimal yields,whatever the weather with excellent low-light _—__ __—
At least 98%of nominal power during first year, H
_t
and temperature behavior. Thereafter mac.0.6%degradation per year.
. --- --------- _ _ --- At least 92.6%of nominal power up to 10 years. , -- _ '
- At least 83.6%of nominal power up to 25 years. g.
ENDURING HIGH PERFORMANCE All data within measurement tolerances. Z .
Full waranties in accordance with the warranty Long-term yield security with Anti-PID Technology', a terms of the Q CELLS sales organisation of your
Hot-Spot-Protect and Traceable Quality Tra.QTm. respective country. __ w .�
tmaalaaace fill
EXTREME WEATHER RATING Q CELLS .,...: a �°w a Typical module performance under low irradiance conditions in
�'�1°r' '"`"'a"'"°"'�-'."�'"'°° •'s'^"'°'m"'High-tech aluminum alloy frame,certified for high snow
comparison to STC conditions(25'C,1000 W/m').
(5400 Pa)and wind loads(4000 Pa)regarding IEC. _ -•
Temperature Coeffiaent of I„ a [%/q +0.04 Temperature Coslficiem of Y„ g [%/q —0.28
MAXIMUM COST REDUCTIONS TemperaWre Coefficient of P,a, Y [%/q —0.39 Normal Operating Cell Temperature NOCT [°F] 11315.4(45 t3°C)
Up to 10% lower logistics costs due to higher module
capacity per box.
Maximum System Voltage Von pyp II
Ah____ Maximum Series Fuse Rating (A DC]
--- 1000(IEC)!1000(U2L0) FSafety re RRa<m< C(IEC)/TYPE 1(UL)
Quelity Tested -_....A RELIABLE INVESTMENT Design Toad,plait(ALP [Ibs/R'] 75(3600 Pa) Permitted module temperature —40°F up to+185'F
on cadtnuous duty 1-40°C up to+85°C)
Inclusive 12-year product warranty and 25-year **a—*
linear performance guaranteez. ID.40032587
Design load,pull(ALP [Ibs/ft'] 55.5(2666 Pa) 'see installation manual
- ----_ —__ ._._.
•
APT test conditions:Cells at-1500V UL 1703;VDE Quality Tested;CE-compliant; Number ofModules per Pallet 32
IEC 61215(Ed.2):IEC 61730(Ed.1)application class A
against grounded,with conductive meUmber of Pallets per 53 Container 30
THE IDEAL SOLUTION FOR: tal foil covered module surface,25'C,
168 h pyE C E
® Number of Pallets per 40'Container 26 "s
®Rooftop arrays on ' See data sheet on rear for further c rte.•.us Pallet Dimensions(L x W x H) 68.7 in x 45.3 i n x 46.1 i n y
residential buildings information. m (1745mm x 1150mm x 1170mm)
Pallet Weight 1435lbs(651 kg)
NOIEi Installation instructions must be followed.See the installation and operating manual or contactour technical service department for further information on approved installation and use
OCIELLS of this U roC uELL H
Hatmha•CELLS ANtIp lee.
Engineered in Germany 300 Spectrum Center Drive,Suite 1250,Irvine,CA 92618,USA I TEL+1 949 748 59 96 1 EMAIL inquiryeus.q-cells.com I WEB www.q-cells.us
d,� y�� �yyg�
P MODULL 1 M�7
SCALE NTS
Z-102
1 r
soIar _
solar
LSEf
� .... � �Q�.-. x... .....,a .w+.............._ t.:- t.r+3r��"
r .m
for North America
. ._
.
•twus Output�x�y �_,.,....�. .. ....... .x .�a...� ...�_ .. �_... ... �.,,.
� �- ors #A
Utility Monitoritg.
Irar ..x . .Tx .., a x, .., ..... ........; . ............_..
MaxImum Input Current 240V 8-5 10.5 13.5 163 Mt
W k �4
....... ... . ................... ...........
.� t.ilif i<
I: ____
ter_
� . . . .... . . . ... ..- s
�..
• y`�,�ls y �i�jy 075-1 x }fvn
r � S... � .�55 Optimized Installation with HO-Wave technology
Nabjral
........
• Integrated Arc Eadt pvoteetion end Rapid Shutdown for NEC 14 and 2017,per arlide 690.11 ndt≥
fit! and easy 4 n ` .
Z-103
EXAMPLE OF RACKING LAYOUT
ACTUAL RACKING LAYOUT DETERMINED BY CONTRACTOR
MODULE
TOP CLAMP
R PV TRANSITION BOX
MODULE s I X I"ss
MOUNTING RAL HEX BOLT
TOP CLAMP X I'SS
-HAD SPACER L-FOOT �
MOUNTING RAIL - 5ns"ss SPLIT F s IUD ER .EPDI�G 1O
LOCK WASHER SS WASHER
-FOOT
5/16'X 1'SS POST
FENDER WASHER 6.18 SS 1-1/4'ID EPDM COL
�/ HEX NUT COUNTER FLASHING
/ U�IOdOUNT PV FLASHING QUICKMDRNT
��5/11r x 6's ' UNIVERSAL TILE MOUNT FLASHING
HANGER BOLT / a' Q
MfIT1�N
//'�/-. / // .FLAT TILE S� a-
/ 5116'X3'
/
ZINC LAG BOLT f
COMP PENETRATION DETAIL TILE PENETRATION DETAIL
Scale: NTS Scale: NTS r�
1 -
GROUNDING LUG
2s's4" (SEE NOTE 9)
#6 BARE CU GROUND
FOR MODULE GROUNDING
(SEE NOTE 9)
ARRAY DETAILS
MODULE GROUNDING LUG (SEE NOTE 9)
RAIL
' THIS LAYOUT USES (2) ADDITIONAL SPLICES L-BRACKET &
QUICK MOUNT ROOF PENETRATION
OPTIONAL LAYOUT SPLICE CONNECTOR
Scale: NTS
MECHANICAL NOTES:
1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND EQUIPMENT INSTALLATION INSTRUCTIONS.
2. ROOF MEMBER STRUCTURE:2"X 4"WOOD RAFTERS AT 24"ON CENTER.
3. ROOF CAN BE COMPOSITION SHINGLE OR TILE WITH A PITCH BETWEEN 9 AND 45 DEGREES.ALL OTHER ROOF TYPES PLEASE REFER TO SUPPLEMENTAL ALTERNATE ATTACHMENT/FLASHING STRATEGIES. -
4. MODULES MOUNTED TO ALUMINUM RACKING SYSTEM AND ATTACHED WITH QUICKMOUNT PV MOUNTING SYSTEM OR OTHER FLASHING/ATTACHMENT SYSTEM APPROVED BY THE RACKING MANUFACTURER
5. DISTANCE BETWEEN PENETRATIONS NOT TO EXCEED 4.00 Fr.
6. RAIL OVERHANG FROM PENETRATIONS NO TO EXCEED RACKING MANUFACTURER'S SPECIFICATIONS.
7. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS WHEN PREPARING ROOF FOR RACK INSTALLATION BUILDING.STRUCTURAL INTEGRITY AND WATERPROOFED PENETRATIONS SHALL BE THE RESPONSIBILITY OF THE INSTALLER
8. ADJUSTMENTS MAY BE REQUIRED DUE TO EXISTING ROOF LAYOUT. Z
9. FOR INFORMATION AND DETAILS ON GROUNDING OF THE SOLAR MODULES AND RACKING SYSTEM PLEASE REFER TO THE SPECIFIC RACKING MANUFACTURER'S INSTRUCTIONS. .
1 MAT1CKt# OI►riUM19 CERT1140- EI
MRHOFtlWIDN: - _
11rl1ryYa�rwz b ' iii 31930
j 5Fb17riYJIi�M�FMYKwii - -. _- .. -
' `. ..F, 149i61umNl�lw�y GENERAL RACKING LAYOUT t44AE_ STAiELKBNSE
a1 � S-102 7a�3o
1 '
S-102
I' -
{
�1r L11E(g�M+jIN1�48A8
RMA
system Certification try a Florida Licensed Engineer I 1 QC295with Solo Edge Inverter
scent Sine DLL 2.36 to S.o2kW ' 531 to 6.79kW 7.1 to 9A4kW 9.74 to 1151kW
June 28,2017 ►MOD1A ES AND ARRAY
odule Brand Hanwha Q.C.eU Hanwtna Q-Cell Hanwrlta Q-CeII Hanwha Q-CeH
Dear building official, odule Site&model 295W Q.Peak BLK-G4.1 295W QPeak BU(-G4.1 295W QPeak BLK-G4.1. 295W QPeak BLK-64.1,
odule FSEC 9 QC17-NT90-0177 QC 7-NT90-0177 (X17-N 90.0177 QC 7-NT90-0177
On June 23`d of 2017 Governor Rick Scott signed HB 1021 amending 377.705 of Florida Statute tal Number of PV Modules 8 to 17 18to 23 24 to 32 K3WIngs
39
authorizing solar energy systems manufactured or sold in the state to be certified by professional ries Strings/Branch Circuits 1 or 2 strings 2 strings 2 or 3 strings ;engineers.in effect a Florida Solar Energy Center,(FSEC,)certification is no longer required by state '° fli stringof8 1stringof8 1sMngof8 of8
statute for materials or systems to be sold or installed in the state of Florida. ngestStrin61 string of 17 1 of 15 1 string of 16 of 17
ray Na to Power Rating 2360 to 5015W 5310 to 679OW 7080 to 944OW o 11505W
On page 6,lines 138-144 read; )WEA DITIOMNG(hwartar)
All solar energy systems sold in the state must meet the standards established by the center and shall rerter Brand i Solar Up with opthnizers Solar Edge with optimizers Solar Edge with optimizers Solar Edge with optimizers
display accepted results or approvedperformance tests in a manner rescribed by the center,unless renter model number �US SE-5000H-US SE-7600H-US -10000x4-US sP aY P PP P Ong m W.1741 Verified yes yes ; Yes Yes
otherwise certified by an engineer licensed pursuant to chapter 471 using the standards contained in renter DC V window 380V to 480V 38WV to 48av 400V to 480V j 400V to 48pV
the most recent version of the Florida Building Code. :Power Rating 3800W 5000W 7600W , 100001N
Nominal Voltage Output ( 240V 24 240V 240V
Please find HB 1021 attached for your convenience.This modification to 377.705 will go into effect July ax PV array Power per Inverter 4 5900W 0V 7750W € 11800w 13500W
1,2017 amber of Inverters used i 1 1
1 E
wer Optimizer used P320 P320 s P320 P320
If you have any questions,please feel free to contact FIaSEIA at(407) 339-2010 or(800)426-5899 rted Input DC Power } f 32OW ; 32OW f 320W 320W
solute Max Input voltage € 48VDC 48VDC 48VDC 48VDC
Regards, PPToperatin Range 8-4W 8.48V 8-48V 848l
ax DC input current 13.75 13.75 13.75 13.75
The Board of Directors of FIaSEIA ax DC output Current 15A iSA 15A ]SA
axinaxnoutputvoe 6WDC 60VDC ` 6oNDC 60VDC
impatible with all Solar Edge Inverters Yes I Yes E Yes I Yes
a1RME CONTROLLER AID BATTERIES WA i NIA I WA N/A
►TTERY B CON�URAUM NIA WA N/A 1+1/A
Florida Solar Energy Industries Association
(F1aSE1[A)
2555 Porter Lake Dr.,Suite 106 _ r
Sarasota,FL 34240
NOTICE! REVISIONS ORA_____FWAT10N
REV DATE BY DESCRW1'ION DATE: 141!, 7
TM we#A M Ind IdrN Ind 0ltA4V►16Y: I —'
Inn a T L h«ip The SCALE: N:Ta:
popnty dTM��wrEAr TAt ws t. _ -
1123 01tnn FNphwsy of YMr iM�AMti wMw18r
Ode=*,FL 3WM , ar eNc Z-101
813df7M100
2-101
it
PHOTOVOLTAIC IRON RIDGE RAIL DETAILS
MODULE(TYP.)
BONDED
SPLICE DETAIL
XR-100 M
MOUNTING
RAIL GYP.)
)
1 I1-0 r
ASPHALT SHINGLE OBJECT FASTENING
✓ ROOFING(TYP.)
STOPPER SLEEVE
0l XR1M00NOEDSPUCE
SHEATH
(1YP.) IRONRIDGE XR100 SPAN TABLE
72"Spans arepermitted only under the following conditions.
�
All others are limited to 48"spans.
For Exposures B and C only.Exposure D requires engineering evaluation.
GROUNDING LUG Wind Speed Conditions
IVE( NOTE 130mph Zone 1 and 2 all roof pitches 5 to 45 deg,Zone 3 pitches 30 to 45 deg
FNAST NG 140mph Zone 1 all roof pitches(5 to 45 deg),Zones 2 and 3,30 to 45 deg
OBJECT
150mph Zone 1 all roof pitches(5 to 45 deg),Zones 2 and 3,30t045 45 deg
(SEMB E NOTE 10)NO 160mph Zone 1 only,all roof pitches 5 to 45 degrees
Cantilever limited to 40%of span and no splices in cantilever.
Shingle and tile roofs only.Metal roofs require engineering evaluation for pull off.
O scALE:1:1e
- C AUACHMENT DETAIL
WOOD ROOF
L-FOOT TRUSS(TYP.)
XR 100 SPECIAL GROUNDING BOLT&NUT
RAIL
Notes on Racking:
{
1 Only approved racking components shall be used to meet wind load ratings. 8 Modules are not permitted to be installed in roof pressure zones with an estimated uplift
2 Contractor is responsible for compliance with any and all local and National codes that exceed the limitations specified by the module manufacturer(please refer to the module specification
and equipment installation instructions, sheet and installation manual for more details).
3 PV modules are mounted to aluminum racking components and rails 9 Grounding lugs are only needed on one rail per row of modules.Grounding lugs can be installed anywhere
and attached to the roof using Quick Mount PV flashings or other attachment and flashings along the rail and in either orientation.
approved by the racking manufacturer as appropriate to the installation. 10 IronRidge systems using approved Enphase microinverters eliminate the need for lay-in lugs and field
4 Maximum span between attachments to be 48" installed equipment gounding.This solution meets the requirements of UL 2703 for bonding and
5 Please refer to manufacturer's installation instructions for rail cantilever distance from roof attachment grounding and is included in this listing. Specifically,the Enphase 1Q6 and 1O6+inverters have a
6 Contractor is responsible for ensuring watertight attachments and for sealing,trimming,cutting roof nonconductive base and do not require grounding.The Q-Cable,however,does not contain a ground,
shingles and membranes in a neat,professional and workmanlike manner so modules and rails must be grounded externally and grounded at the breaker panel ground rod in -
7 Different rows and columns are permissable as long as the attachment requirements listed unified grounding.
in#4,maximum rail overhang,and maximum module overhang from ends,does not exceed _
manufacturer's recommendations.
NOTICES: REVISIONS DRAW M®FORMATION I CERTIMATE OLEVIF
_.. AUTHCRSAMONd /�/
The dmWd•and k1m REV DATE BY DESCRIPf0N OATS 1111nvf7
hwe ri1Nn rn am�Y,sirs DRAM BY: I ]] ��/
pwpwly efTM LsssrEdps TM r — �- `� 6
_- SCALE: N.T.S.
1423 Gunn Highway aawr wstwiW"rrldrord tors SHEET NO-. ..
Odessa,FL 33556 vrMMn co ssrd d Ow LE w 1NIC"
8134035100 ssstprsrtwd S1
S-104
• LUG OPTIONS UNIRAC S LAR OUNT` RACKING SYSTEMS
y� MODULE TAIL
MOUNTING
RAIL(7YP.)
ILSC0 LUG - - . ASPHALT SHINGLE
END CLAMP
SHEAThING
A thsrm biedi is every 40 feet of connuousty cormecledMID-CLAMP
r#If;B c rme bR gt Use saiWit;bne - ASSEMBLY
tr S two 15501595 0 etf ie►.tom 1`P/N ..4 .
see-da sheet far more ds #solid ooipert
3rd RAIL LOS ON
(TYP IF REQUIRED,
SEE STRUCTURAL)
11 om
N ASSY
ThMALDAMSION XW
�Ii tt#I<�iSl�t
Notes on Racking:
1 Only approved racking components shall be used to meet wind load ratings. 8 Modules are not permitted to be installed in roof pressure zones with an estimated uplift
2 Contractor is responsible for compliance with any and all local and National codes that exceed the limitations specified by the module manufacturer(please refer to the module specification
and equipment installation instructions, sheet and installation manual for more details).
3 PV modules are mounted to aluminum racking components and rails 9 Grounding lug options are required if not using approved integrated groundin gmicroinveters.
and attached to the roof using Quick Mount PV flashings or other attachment and flashings Please refer to manufacturer's installation instructions for both WEEB and ILSCO products.
approved by the racking manufacturer as appropriate to the-installation. 10 The Enphase M215 and M250 microinverters have integrated grounding capabilities built in.In this case,
4 Maximum span between attachments to be 48".For the attachments on the ends the DC circuit is isolated from the AC circuit,and the AC equipment grounding conductor(EGC)is built in of the rails each side. to the Enphase Engage integrated grounding(G)cabling.No additional EGC grounding cables are required, `
5 Rail overhang from attachments to roof to be less than 16". as all fault current is carried to ground through the Engage cable.The Enphase IQ6 and 1Q6+inverters have
6 Contractor is responsible for ensuring watertight attachments and for sealing,trimming,cutting roof a nonconductive base and do not require grounding.The Q-Cable,however,does not contain a ground,so
shingles and membranes in a neat,professional and workmanlike manner. modules and rails must be grounded externally and grounded at the breaker panel ground rod in unified
7 Different rows and columns are permissable as long as the attachment requirements listed grounding.
in#4,maximum rail overhang,and maximum module overhang from ends,does not exceed
manufacturer's recommendations.
rcoxYes
Qi4iMfa0
tf B',
S-103
.s a
a z
C t Fo M f
Yd�
h. 1
awrr r td
rr�a.r �aee
, '+a- -1faYlRS` -atlMMAa
- vz fi •z a w ,
a tr a 7 a
{ " G.• r-x r. !�' ..-x. r ...�-..... ,..v.- r m 1^.. ice.
S�146em,�W .�.._ .,;. :>�,aW, .>.aa• f L.: tip. ...,�:-�";. _,4H a+
S.sarr - `r tb+..A: .ks flAt..su. - ,- ., ,.,.,�, :a..,,y x•wR' i ' g:. Yr- v a ^'" T^.".�y°°9
Remy g'6
R • ,�' mkai..R
"Ye+` x j.. i ti }i�RKrs� zuR g f �. .��` I * i ifLZT
eJws�v.Y:to #me�
�ry p f_1
w w�Ioresw f�
11 DESCRIPTION QTY.
I CAP SCREW.HEX HEAD.5/16"--18 X 3/4"UNC-2A,GRADE 8 1
NO. DESCRIPTION QTYJBOX 10 2 QBASE.1-114'ID.FOR 5/16"HARDWARE A360.1 CAST Al. I
NO.
I FLASHING,9"X 12'X.040',5052.MILL 1 3 LAG SCREW.HEX HEAD.5/16 X 3',ZINC 2
2 QBLOCK,CLASSIC,A360 CAST AL MILL 1 9 4 SUB-FLASHING,CONE,9'X9'7(.02P/.032'.3003 AL MILL 1
5 FLASHING,CONE,18)(18"X.037.3003 AL,MILL 1
3 PLUG,SEALING,5116"X 7/8",EPDM/18-8 SS 1 8 6 COLLAR.COUNTER FLASHING.1-1/4'ID EPDM I
4 LAG SCREW,HEX HEAD,5/16"x 5-112,18-8 SS 1 7 POST,1.25 OD X 6.5,6063-25/6063-T6,MILL 1
5 WASHER,FENDER,5/16'S)X 1-1/4"00,18-855 1 8 WASHER,SEALING.5116'lox 1-114"OD,EPDM BONDED SS 1
7 9 WASHER.FENDER,5/16'S)X 1"OD.18-8 SS 1
RACKING COMPONENTS 10 WASHER.SPLIP-LOCK.5/16'D.I8.8 SS I
NOT INCLUDED 6 11 CAP SCREW,HEX HEAD,5/16-18 X 1'UNC-2A,18-835 I
S. and Barrel Tile Standing Seam Clamp ;1 4 5 Notes on Flashings and Attachments:
(QBase Universal Tile Mount/QMUTM Shown) I Il ,
3 ` 3 4 1 Contractor is responsible for compliance with any and
all local and National codes and equipment installation
3 �. instructions.
2 PV modules are mounted to aluminum rackin
9
2 2 components and rails and attached to the roof using
1 1 Quick Mount PV flashings or other flashings and
1 attachments approved by racking manufacturer as
mount PIS` appropriate to the installation.
TITLE: G*k Mount r'T
QMSE-LAG:QMP M V E- OUNT — 3 Maximum span between attachments to be 48"or less.
WITH LAG BOLT QMUTM:QBASE UNIVERSAL TILE
MOUNT For the attachments on the ends of the rails each side,
Composition Shingle Flat Tile the span can not exceed manufacturer's
(Emount/QMSE Shown) (OBase Universal Tile Mount/QMUTM Shown) recommendations.
ROOF MOUNTING DETAIL In • w�, `-�""`'""' 4 Contractor is responsible for ensuring watertight
SCALE: NTH
, �M=4 penetrations and for sealing,trimming,cutting roof
t�»••► shingles and membranes in a neat, professional,and
Alternate Tile Strategy:Quick Mount Tile Replacement Mounts(QMTR-BM) g
workmanlike manner"
p,�.,.�` tenHor4x
Note: Protea is limited to 40psf when used with
an equal number of PV clips in a 24 ga steel roof.
See LeverEdge Engineering for higher uplift loads.
LMx+■.�1
-w
tai.IF*
133
(38.88•M MUM n069AV r�ai.+awr.aeo..r:..maRr.a�q.e., `.,
S-5U and Mini Protea
STANDING SEAM TRAPEZOIDAL
Metal roofs are made by several manufacturers using several different styles from standing
seam to 5V and others. S-5! makes clips for each particular roof style. It is the contractors;
responsibility to determine the particular brand and model of roof and select the proper S-5
clip for their particular installation. Check the S-5!web site at www.s-5.com. Installers can
access the tools and procedures for proper installation of the clips at www.s-5.com/tools.
Proper installation is critical to achieve the rated pull and slide off values listed.
FLASHING CUT SHEETS
Quick Mount Flashings
rMiarl�Lllnrri The LevorEdge �� ��
�"r ► w1w 1423 Gunn Highway Certificate of Authorization#: J ______________________ ______ -
IIMr
a rNr M� WU ,423 , Odessa,FL 33556 31930
�,rrli..rra ft" 813-403-5100 S-101 -
S-101
DANGER 4 STOP !
Do NOT TOUCH TERI INALS
DO NOT DISCONNECT DN. LBEAND
,� LOAD fHDBs YAY BE E ERGE=
UNDER LOAD E POLARITY OF CABLES MUST BE LABELED AT «THE OPEN Po�TION
OR NEAR THE COMBINER BOXES AND
INVERTER CONNECTIONS ON THE DC SIDE • • i
A WARNING LABEL TO BE AFFIXED TO RAIL OR
ON SIDE OF PV MODULES IN CONSPICUOUS LOCATION 4.1a� I S
I r'°ut
$ G SOLAR DISCONNECT SWITCH ON AC DISCONNECT SWITCH IF
USED.REQUIRED ANYTIME LINE SIDE TAPS ARE USED FOR THE EL O NOT:AL sHw ER x IALS O
SHOCK � POINT CONNECTION TLOAD SIDES NAY BE ENERc D
EIMINALS ON BOTH LINE AND
ELECTISCAL SHOCK HAZARD DD p
UCH TAL.S M TiE OPEN POSITION
RFA6110111D FAIAXNPIDN•.AI TWN ROTNL«EMD
LOADArsE®IERa®
NOES Y«NIUMOEp CON«RCTOB POSITIONBAYSEUNOINIUND®AMD«IEIIO OCVOL ALIIMYS PRESENTMNLAR MODUL90 7MF=7WR
OTARE I VOSW TO SU1N.pMB AFFIXED ON COMBINER BOX
ELECTRICAL SHOCK H1ATJIRD I AC SIDE OF SYSTEM DENTING THAT
FAOROIRD FIWLT K SoIOA m THE PANEL IS DOUBLE SOURCED AND
UT1fTr I.ETER THIS MUST AFFIX NEXT TO THE PV
I26V BREAKER INSIDE THE PANEL
F DC DISCONNECT LABEL AFFIXED ON OR BESIDE H AFFIX TO INVERTER SIMME`PHASE
INVERTER'S DC DISCONNECT SWITCH PER NFPA
K
ELECTRRCAL«HOCK HAZARD
D (M) A
DO NOT(OUCH IEINA«ALS
TEIN.IAL.S ON DOIII MEAND
LOAD,IOB rAY SE A
., «THE OM POSRION - -
j °C wxeR EOLAR MODU MNIt11 tN IWERTER"no
ARE mwom To suNLIDHr ,
H D _\
J AC SIDE OF SYSTEM BY PV
BREAKER IN PANEL
C INVERTER LABEL TO BE FILLED OUT WITH SYSTEM SPECIFIC
DATA AND PLACED ON THE INVERTER OR CHARGE CONTROLLER I I B,E F
K pv
JUIVC TM3N� - PVAC DISCONNECT PERF0R NAi'ICE 200A MAIN'
I EXISTING
TRAMMONIN0fTOfltPV
wm TO Tmvv" 304.24W.2401 METER SWITCHBOARD
{SEE NOTE 9) NOTE
Must be reflective Per . - - • •
s • L J
NEC 630.31 & . • • .
lFC 605.11.1.2- NDR�A6231G
D REFLECTORIZED LABEL TO BE PLACED ON ALL CONDUITS AND / a I I
D D H,J NAVES INIOROISOlDAfOBBRO®
RACEWAYS THROUGHOUT THE SYSTEM TO ALERT FIRST K AFFIX ON METER CAN FOR
RESPONDERS NOT TO CUT CONDUIT WITH AN AXE DUE TO RISK
BI-DIRECTIONAL METER
OF ELECTRICAL SHOCK QFC 605.11.1.1) GrDUnd,%
CERTIFICATE OF
AUTHORIZATION#
31930
ENGINEER OF RECORD
- JOHN L.ALGER
II PROFESSIONAL ENGINEER
FL.LICENSE NO.74730 -
NOTICES: REVISIONS DRAWING INFORMATION
REV DATE BY DESCRIPTION DATE: 50512017
TM N And dw a cspnaad �"!
- •��»* PLACARDS FOR TYPICAL DRAWN BY: -
prapMlY dTIM L,, wom TM ur SCALE: N.T.S
44423GunF 33556 ,r , STRING INVERTER PV SYSTEM E-103
Odessa,FL 33550
813.4035100
E-103
4
_ KI _
I I __ __
Main Mali R.qi*id lockable Mai
.FUN
ifr MM Ct11 rN URa
0Me 240 V - •*..- ksysrier cry Wilts
maybe
ioosT u iriY4 240
ExistingAC Eda1ingAC Inverter ExlSttng AC
1 distribr. n panel OpNon lockable distribution panel distrIbution panel
240 V . 120f240 V 1 PH non leesd 30A 1 1201240 V I Pit W 120140 V I PN
IAW
PN 8tasalGeYT Ground Grwlraioconnact
Oppodte main breaker main and brtrn of de alr m t aura
buss leoonn.dorponel
grounds le avoid perakl
PV Breaker+Main breaker PV Breaker+Main breaker rreWral wire Line side connection required when PV over current
must be S 120%of buss rating must be S 100%of buss rating device+Mein panel breaker>100%of buss rating
PANEL CONNECT OPPOSITE MAIN PANEL CONNECT BETWEEN LINE SIDE TAPS
HOUSE CIRCUITS
1-WIre sized per voltage drop table,
usually#10 or#8 on 125% of 2-Wire from disconnect to connection point to be#6
MSAMUM continuous Inverter output amps. THWN-2. Distance from connection point to
lJpsizing of wire from#10 to#8 is permitted disconnect panel not to exceed 10'and must comply
to reduce voltage drop. with NEC 2014 240.21 (Bx1).
3- Line side taps may be made with double lugs in the
box or meter can or with polaris taps. Rating of the
connections must be rated at least 125% of maximum
inverter output current.
4- NEC 2014 705.12(A).The sum of the overcurrent
protection devices from the PV system connected to
the service conductors,cannot exceed the service
conductor's rating,when using line side connections.
CERTIACATE OF
AUTHORIZATION# -
31830
ENGINEER OF RECORD
ty JOHN L.ALGER -
J
tt PROFESSIONAL ENGINEER -
FL LICENSE NO.74730
is
NOTICES: REVISIONS DRAWINGI Fces TIoN - _ /"
�v�r ,►r► Thoarwr"OWideftOWwawd OPTIONAL CONNECTION DETAILS REV DATE BY DESCRIPTION DATE: 7052017
propMy of Ths I.swrWW A d use SHEE N.T.S. 6
1423 Gunn Highway dtMr m�wiNs wNhwa tlr STHEET NO
Odessa,FL 33556 wriusn eorwsst L w ENC.
II �
813-403-5100 E-1 01 A
-101A
Table ft901.2 to am of Ivy 1>tQ ft modtlie or collectorT r ENGINEER:
r�-1 HOW TO USE THIS TABLE AND FIGURE: JOHN ALGER
4105 SAINT JOHN'S PARKWAY
ioçt 3x1 220 360 120 160 1416 170 175! 113 SANFORD,FL 32771
0" w dais we dwa dery wO a w wM , „ O aawa WO 1. Determine wind zones on roof from figure. "a" is 4 ft in all cases.
1 20 -272 1@ 4X2 11 392 •103 362 51.4 333 '13 -342 222 -Ix 235 -JL7 PH 800-929-3919 X1411
0-7deg 2 10 37.8 10 341.1 1s -961 10.7 -42 UA -44.7 i2 J73 123 505 135 537 2. Obtain the wind speed from the local authority having junsdtction I jaige everedge.com
3 10 -a" to J53 10.7 554 UA -u 12 -sale US -711 135 76.1 State L tense#74730
1 -1 513 -9L3 -13 41.1 •34.1 151 435,7 167 172 17.3 333 u1 313 3. Note roof pitch and mean elevation(height)of the roof and round
3-Ia dig 2 131 16.5 133t 13 35.4 -44d 151 #71 1417 -641 173 - >,a! 4I.i up. Ex.14 ft,use 15 ft. =BY.63 10.1 -10.5 113 13 -x1 14.5 -61 151 -60 241.7 77 171 776 113 -7!1
1 1413 -!2 siL 247 362 Iii -2/s 371 33at Is6 Its 319 J36 4. Pick the table for exposure and mean roof height.
2•-464* 2 16,3 14.2 213 -29.2 31.7 -+27.2 24.7 -30.4 24.3 324 370 44.# 316 47 *13 -115
3 183 10.2 115 192 31.7 372 347 93.4 63 52. 371 I.L4 20.5 333 Example:Category C exposure-site conditions with some flat
boors.!;mion roof hws 15 Rand,rtlir.tGl-A,tilt-7 oad iamedr r4r+wnt 9ifto-121 areas and 15 ft means the mean roof height is no taller than 15 ft.
rarer FAM 230 140 1501 760 lib 17O 175 100
fry 2m darn wo darr wff2t dirsi wo do+re wm dawn 1113< da�� wo dares MM dawn 5. Locate the column for the wind speed and circle the down force
and pressures for the three roofpressure zones. M`°`�
i 22,1 331 12,1 34.4 119 341.7 '12.0 117 1x1 -x4.1 245 345 255 -30.1 163 19,2 uplift nA�:avav2on o-.�ar
1IE tEYr1�
0.74* 2 121 -3x.4 12.1 135 i l -its 121 -ag 13.0 -541 545 57.1 255 41.1 163 154 I 14namftlarra/
3 12.1 � & 522 55 4 11.9 -412 121 711 DA 751 US -"A 155 -as 163 42.1 6. Uplift pressures up to 55.6 psf are below the module rating and thus, I 61 LDR-SI-SE-OC295M
1 221 -114 11.7 22.0 15.7 -264 172 -26.3 11.1 -31.1 202 13.1 215 -15.5 22.7 -57F.1 modules may be installed in roof zones lower than 55.6 psf or lower rxrinaM d Rev.04.16.18
3-274* 2 522 -32.2 197 -'31.0 157 -40.1 171 -43.4 711 -U.0 *2 -463 22.5 44.7 73.7 43.0 I. Autliarm un# 14:I0
1 122 4113 13.7 -8A 15.7 461 17.1 73.0 111 -U.S 203 -13.2 21.5 -33.1 217 444.5
1 11.7 301 221 34A 243 30.2 305 31.7 35.0 30.5 331 356 360 3L2 371 40.7
36-414* 2 10.7 -24A 221 31.2 Iii 121 211 -x6* 31.3 -Ml 3" -416 351 -441 331 473
1 3 21.7 -14.4 221 30.1 283 -32.1 213 -360 331 -30.2 99.1 41.6 351 -441 375 -a.0
Eslpo�w4 m ► ltl�lil5-9i�.1d.A5 at4il 11"0 tiro�tf-1A NOTES:
roe► flier 130 140 250 144 545 170 575 713 �; 1°#" 1. Pressures shown are applied normal to the surface,
-- Ame dare WO dwm w3� dnam o t OWM !Mt Barr darn writ daiin wfflt darn wfst for exposure B,at h=30 ft(9.1 m).Adjust to other
1 140 34,1 14A 313 2x+0 ,IIZ? 1SA -SL7 MA 30.5 15.1 -413 175 .462 gas 4 4 ' conditions using Equation 30.5-1.
0-74* 2 140 •33.6 14;0 -44.5 13.0 -1S 151 160 -L6 141 -461 173 70.7 lu 75 2 ,
3 14.0 14,1 141 7 19 31 721 -iii • 2 14io ia1 1 .1 4W6:4 171 100.7 Sss -lobs @, ?. Plus and minus signs signify pressures acting toward
i and away from the surfaces respectively.
1 -2L4 ss s 355 is 2 .u s 321 t6a revs 39.1 345 4 a X3 •w a ' , , ,
8sT
0-27d* 2 141 -17.2 351 -14.0 112 -*s 20.7 571 21.1 .56.1 23.4 767 245 741 243 721 j # 3. For hip roof angles less than or equal to 25 degrees,
3 141 -66.1 15.0 -40.2 252 75.3 20.7 -&A 321 -365 314 -147.0 241 -tQ0.6 Iii 1333 4,. shall be treated as Zone 2.
1 23.41 -261 265 30.3 WA 42.5 144 -367 361 -30.1 911 -42.2 415 -44.1 4 3 -471 WMIS 9 s F
>1-36do3 2 US -au 265 12.5 nA J3.1 94.41 -42.5 343 466 31.2 -441.2 CA 511 03 353 Noter =4fisetias 'eseis, h: Mean roof height,in feet(meters),except that
3 329 3Lx 365 4" 33.4 30.1. 34.5 J26 161 311 d33 53s as - s eave height shall be used for roof angles<10°.
Uooiw D m. irsoh lS*md s - lft -
ont fad >90 Les ss3 1415 va 175 4153 3 + f 0: Angle of plane of roof from horizontal in degrees.
3Nex am down wfrt der m dWW wrt darn oft down WO dames W ft" 00 dare 0Mt i ill r,
1 14.7 353 14J 31.7 13.7 14.1 15J7 -0.5 1411 411:5 17.4 w4 4 115 -435 ills -62.5 " ' rr f '
tom, ,��
�h s
0-70* 2 14.7 4041 1+L7 467 337 6�+F.i 15.7 11.7 14# 415.7 ?±. .. 2 L ... 111 Al ; t ', F _i. ; ` '
3 14,7 .2 147 16773 13.7 %7 15.7 -173 lit -111 17.4 -19.,4 311 -*1.7 211 1111 i j , 7•<0 46` ++ 7•s@27'
1 14.7 31..5 16416 341 19.1 -36.0 221 356 222 -57.1 34.5 -40.0 *2 -41f.1 276 141 -a
I-Vft 2 AS *1 146 16.2 11.1 5Lx 21.1 -60.0 23.2 703 245 410.6 Iii2 716 236 76.5 84gg g -'4
3 141 -517 1666 41.5 13.1 7111 211 1107 ?!.2 -1414 245 -11x.1 262 13.1 7.4 -193 7"ce 545• HIPRCOFS
i 241 ,253 271 -2163 311 -94.1 *3 315 331.7 10.1 411 -40.2 * -46x 460 -#0.4 7'<Bs27'
31-414* 2 245 30.1 271 3L3 31.3 -400 341.3 -44.1 33.7 - 76 415 -D6 141.4 4 461 511
................................................................................................................
3 24.0 31.7 271 -a1 311 -46.0 343 -43 357 47.6 411 -06 435 54.4 481 -0.i
130arree44 nM1n nxtit 1543 31R I31= ffit-lasds�uidmorlfae4ar-lib
rssr !roar 231 to 193 1413 1416 174 175 110
{ pfd �wds Barr v$* diver oft dawn t 4366 apMt down rft down % t darr wMt daua M Mt E
1 415.5 -10.6 us -15 15.4 365 171 365 711 461 133 601 21.2 541 723{ 9!3
0-74* 2 14.4 -45.1 26,4 52.1 151 41.1 171 -4/.7 211 743 11s -*4 21.2 -La 214 -01.1
3 166 -.? 13 -76.0 1554 -167 171 -01.6 211 -*1.4 2911 -123 21.2 -111.4 ZIA -1363
1 Iii -66 lia -10.1223 -16.226.6 -40.2 212 -41.127.7 362 315 43431.2 -62.0
3-27drg 2 ill -44.2 1S3 -63 276 1 244 -41.7 262 70.3 273 4.0 2x4 -11* 373 -45 - -
3 7413 -41.4 115 771 2141 iii 24.6 -1013 282 3943 273 3231 315 -1316# 312
1 271 30.5 31.4 -33.5 *0 315 41.0 -435 +11.7 -461 463 -441.1 431 -6,2.3 5521 -U.S
2a-45411 2 271 -36S 91.4 -33.5 36.0 -36.2 431 505 415.7 -6Lg 46 57,1 431 -62.4 52.4 -66 %` \'
3 27.1 315 31.4 335 3641 453 433 505 41J7 -31 463 -"1 404 -1.4 520 -66
Per Florida Building Code,effective area to be taken as the surface area of 1 module or panel
Tables interpolated from 2017 Florida Building Code-Residential,6th Edition(2017)Page 25 as allowed for effective area
42 ,'," '
Table values have been adjusted and recalculated for height and exposure using adjustment coefficients in Table 301.2.3
Table values have already been multiplied by.6 to convert component and cladding pressures to ASD.
Values given in PSF(pounds per sq ft pressure).Positive values indicate down force;negative values indicate uplift.
A-100 ••.............................................................................................................•
g I8 I 7 I 6 I 5 I 4 I 3 I 2 I 1
SCOPE OF WORK: Solar electric PV system Improvement/Retrofit-Q-Cell 295 JOB SITE ADDRESS: %4!e)cJOHN ALGER
mono(nodules mounted on Iron Ridge or Unirac rails with Quickmount or ` 4105 SAINT JOHN'S32771 PARKWAY
�_ U►C VAS ����� SANFORD,FL
equivalent Code Compliant flashings.Inverter is Solar Edge with Optimizers. }
PH 800-929-3919 X1411 A
A The scope of work is to verity that the solar electric Photovoltaic system specified PROPERTY OWNER NAME: ���\�.M �:�.,.(� �
jakpr@# *weredge.com
in this document,meets the requirements set forth in the 2014 NEC,the 2017 FBC State License 174730
6th Ed.and any other Local Utility requirements. MAJOR EQUIPMENT USED: RAILS:BY UNIRAC OR IRON RIDGE
MODULES: HANWHA Q-CELL CONTRACTOR REQUIRED TO INDICATE SYSTEM SIZE
295M 60 CELL MONOCRYSTALLINE GROUNDING:EXTERNAL FOR MODULES BY SELECTING THE CORRESPONDING BOX BELOW. _
B, 295 STC RATED OUTPUT AND RAILS,#6 BARE COPPER
INVERTER:SOLAREDGE WITH OPTIMIZERS FOR EXPOSED AREAS,UNIFIED PHOTOVOLTAIC
The Right Way! 3800,5000, 7600,AND 10,000 WATT GROUNDING ON SAME GROUND
SYSTEM SIZE:
GRID-TIED INVERTERS ROD AS MAIN BREAKER PANEL
B Quick Mount PV WITH P320 OPTIMIZERS JUNCTION BOX:SOLADECK 2.36-5.02 KW I B
RESPECT THE ROOF NO BATTERY BACK-UP UL 1741 LISTED 8-17 modules
OCELLS INCLUDES RAPID SHUTDOWN COMBINATION,TRANSITION #modules:
I �A IN THE INVERTER CIRCUITRY FROM PV OR USE-2 CABLE TO
a Hanwha� ,� FLASHINGS:BY QUICKMOUNT PV,UNIRAC, THWN-2 CONDUCTOR,
A HILT GR0UP C0MR4NY
OR IRONRIDGE OR CODE COMPLIANT EQUIVALENT FLASHING TO EXCEED FBC REQUIREMENTS
T INCLUDES SHINGLE,TILE -6.79 KW DRAWN BY:
IRONRIDGE ROOF BRACKETS:BY S-5! 18 modules
modules: JOHN ALGER,PE
S-5U OR EQUIV.FOR STANDING SEAM METAL ROOF
PROTEA BRACKET FOR 5V ROOF
C C
NOTES: PRMDM
1 Wind load calculations based on ASCE 7-10 Components&Cladding simplified method and are 5. Modules must be installed on 2 rails as shown
porter pl' per the rail module manufacturer's instructions to
multiplied by.6 to convert to ASD per 2017 FBC.As such,the maximum elevation is 30 ft with tables obtain the listed wind rating. 7.08-9.44 KW odes..,Fl.33038
for exposures B,C and D. Broward and Dade use Exposure C and D. 24-32 modules 81100 _
2. Wind force estimates are area dependent and 6. Combined module and rail dead loads are under 4 psf. #modules:
epe per 2017 Florida building code 6th Ed.,the area used r31000
for calculations is 1 module or 18 sq ft for the 32mm frame O-Cell modules 290 through 300W. 7. Rail attachments shall be onto minimum 2x4 trusses or rafters spaced no further apart than 24"on
center. Attachments in roof zones 1 can be alternate from top to bottom at 48"on centers but
3. Installation must comply with all applicable 2017 Florida Building and 2014 NEC codes from which attachments at the ends of arrays shall be 24"on center.'(refer to mechanical drawing#M-1 00).
these plans were based.
8. These drawings are only applicable for flush mounting to a roof with an air gap between 2"to 10" DATE 04125/20171:30 PM
4. Modules installed per these drawings are for O-Cell 290 through 300 Series, (32 mm frame)listings between module and roof surface. This requirement eliminates the module and racking from being 9,74-11.51 KW
D
D with a maximum uplift of 55.6 psf for side mounting. Installation in pressure zones exceeding this considered as part of the building envelope. 33-39 modules 61LDR-Si-SE-ciczs5M r `
rating is not allowed. I
#modules: Rev.04.16.18
Page Title Content Rev Date Notes _
Cover Cover General notes,site details,system selection 00/00 1 APPUCABLE CODES
A-100 Roof Wind pressure tables and"A"dimension calc A, 00/00 1 -Florida Building Code 6th edition 2017
�HA�L CGIIlA�Y WITW f�SAl�r 00/00 1 •..................................................................................................................
E-1 01 Electric Diagram Electrical Line Diagram for Load Side Connect(in _)RIDq -National Electric Code 2014
�DIN� ,0
E-101 A Electric Diagram Optional PV connection methods NA'' L E EC'I'DtG COD . 00/00 1 -NFPA 101-2009
AND THE QITY OF INYI E E-103 Placards Warning labels and where used 00/00 1 -NFPA 13-2007 ORDINp�y _ E
S-101 Flashing Quick Mount flashings and S-5!cut sheets 4� 00/00 1
r
S-102 Layout General rail and module layout suggestions REVIEW p 00/00 1
S-103 Unirac Cut sheets and grounding notes on Unirac rails CITY OF
ZEP �� 00/00 1
S-104 IronRidge Cut sheets and grounding notes on IronRidge rails FLgN HYRHi 00/00 1 NOTES A -
_ EXAMINE S = _
Z-101 FLASEA Letter Engineer certifications for 2.36 to 5.02,5.31 to 6.97,7.08 to 9.44, 9.74 to 11� tems 00/00 2 1. Drawings,calculations tables >
developed requiring a PE seal and - -
Z-102 Module Cut Sheet for Hanwha Q-Cell 295W 00/00 2 signature fir''
Z-103 Inverter Cut Sheet for Solar Edge Inverter and Optimizers-3800,5000,7600"H"series 00/00 2 2. Support documents,cut sheets,tables, '
,-
Z-1 04 Inverter Cut Sheet for Solar Edge Inverter and Optimizers-10,000"A"series 00/00 2 reprints from publications such as G
F ASCE 7-10, shop drawings drawl s that do ���O F
not require a PE seal and signature
...........
COVER