Loading...
HomeMy WebLinkAbout18-20096 CITY OF ZEPHYRHILLS 5335-8TH STREET • (813)780-0020 20096 BUILDING PERMIT PERMIT INFORMATION LOCATION_INFORMATION Permit Number: 20096 Address: 7301 GALL BLVD Permit Type: SIGN ZEPHYRHILLS, FL. Class of Work: MONUMENT SIGN Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 34-25-21-0080-00000-0060 Improv. Cost: 13,183.50 -OWNER INFORMATION Date Issued: 8/16/2018 Name: SAN ANTONIO CF CREDIT UNION Total Fees: 232.50 Address: 7301 GALL BLVD Amount Paid: 232.50 ZEPHYRHILLS, FL. 33542 Date Paid: 8/16/2018 Phone: (813)782-8200 Work Desc: MONUMENT SIGN (B) 24 X 6.9 CONTRACTORS APPLICATION FEES SIGNSTAR SIGN 165.00 SIGNSTAR ELECTRICAL FEE 67.50 I FOOTER Ins ection a uired ELECTRICAL ROUGH FINAL REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Code d Ordinances. NO OCCUPANCY BEFORE C.O. O OCCUPANCY BEFORE C.O. &—, k, CO T SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received —l� Phone Contact for Permitting ) -- euuonnae Owner's Name o4n�/�a) c���C3 fl_�ro C 6 L2AA0 Owner Phone Number �� ��i 2 Owner's Address 1: 42, 6v do 1f s:.,jo, G1A11c� '6 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS ff7 20 i LL_ LOT# SUBDIVISION PARCEL ID# Z �S v� Ovc^✓ cocree 00 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR e ADD/ALT 0 SIGN Q DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR 0 COMM 0 OTHER TYPE OF CONSTRUCTION BLOCK /JQ FRAME J 0 STEEL DESCRIPTION OF WORK tE�:6-Lc S BUILDING SIZE F SQ FOOTAGE HEIGHT C BUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE PROGRESS ENERGY 0 W.R.E.C. t s-E U-3 =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS 0 ROOFING 0 SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO BUILDER ��"L � _'-_' s �CoJ�Y �t< ,.) ,7- - -, re-- - - SIGNATURE REGISTERED / N FEE CURRENEal Address 7'Z.)U License# s®O,ndog% ELECTRICIAN . T�' C PANY SIGNATURE -- -- REGISTERED N I FEE CURREN N AddressL2 License# rsC_xnc3(_-, PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# 9111091111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,. Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. 0 Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS T YOUR PROPERTY. IF YOU I ND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTOR BEFORE RECORDING YOU ICE OF WMMEiMEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR �=� .71 `$ bscri ibed bswo tc qr a irm efore S this ',au s ri 1 i 9d b o(or affir dZb$for�e this �1 I�� K.G �.U►'C� •El ie'S Y .� ho is/ a personallyknown to me or has/have produced W11c,is/ar personally known to me or has/have produced as identification. as identification. IL /11 \ irULQ Lw Notary Public Notary Public Commission No. a Q o,( 10(05 Commission No. % L)(z J Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �.#V Notary Public State of Florida Tina M Prater 40 Notary Public State of Florida My Commission GG 211065 W� Tina M Prater a Expires 04/25/2022 � My Commission GG 211085 a Expires 04/25/2022 EnCon Services, Inc, j Sign Design Calculations Job Description PREPARED BY: San Antonio Citizens Federal Credit Union EnCon Services, Inc., FLEB#9394 7301 Gall Blvd PO Box 3613,Apollo Beach, FL 33572 Zephyrhills,.FL 33541 813-655-3373 Replacement Cabinet 132"x 119" Nathan P.Presnell, PE 77696 Design per Florida Building Code,6th Edition(2017), Section 16 Wind Load,ASCE 7-10, Load Case: D+0.6W DATE SIGNED: `�,�t,111111111UI//�j��' Risk Category II 7/11/2018````` PN c,EPR�`sy IV Kzt 1 F •�� , Exposure C e-* No 7769 Kd 0.85 * • • * r Kz 0.85 V 150 mph STA E OF Cf 1.47 O••. A� G 0.81 ���ss' .... . Number of Poles z�,,���mN1A1►1������� Wind Pressure PSF 52 111 Sign Area Distance to Center P=Force Moment (sf) (ft) (lb) (ft-lb) Top 109.12 6.05 3403 20591 Totals 3,403 20,591 Required Flexural Strength (kip-ft) 20.6 per pole Provided Flexural Strength(kip-ft) 44.1 HSS 8"x 8"x 1/4"A500 B Steel Tube Flexural Ratio 0.47 7/1 1120 1 8 San Antonio Citizens Federal Credit Union Zephyrhills 132in x 119in Replacement Cabinet ------------------------------------- I] END VIEW 21" TOP VIEW:SIGN A 119" 17" 94" 14112'± 4" 4° 0RAs NEC 8112 8112 SIGNA: MONUMENT SIGN 44.4 SQ.FT.SIGN FACE AREA Scale:318"=1'0" One(1)double-faced illuminated monument sign required,to be installed on existing support and foundation IF POSSIBLE—to be determined by field survey of existing support/foundation. Existing support size for SIGNA is 8"pipe. No existing sign to be removed from this support SIGN A monument sign is constructed of aluminum,double-faced. Internal illumination by fluorescent lamps or white LED,UL approved. EXTERNAL DISCONNECT SWITCH LOCATION TO BE CONFIRMED PRIOR TO PLACEMENT. S a n Antonio Citizens Federal Credit Union Cabinet has 2"retainers. Paint white with smooth finish. Rounded end caps are separated from cabinet by vertical reveals. Ve ' reveals Horizontal and vertical reveals are blue to match logo. are intemalyIlluminated. Is be Face is flat dear acrylic with vinyl copy applied to second surface,backsprayed white. Exact vinyl colors to be determined. H;-LHUe reveals Vertical blue reveals are internally illuminated. Exact method to be determined. are inated. Horizontal blue reveals are non-Illuminated. Sign base is brick,or has bride veneer dadding on all surfaces. Flat cut-out white address numbers,non-illuminated,are mounted to both sides of base. 112" BRICK BASE WIDTH APPROXIMATE slo of landscaping berm,on 120" road-side of SIGNA ONLY, which obstructs sign view ALL WORK SHALL COMPLY WITH PREVAILING CODES FLORIDA BUILDING CODE, REVIEW DATE r 'iI NATIONAL ELECTRIC CODE, CITY OF ZEPHhH - AND THE CITY OF ZEPHYRHILLS PLAN EXAMINER S ORDINANCES CLIENT APPROVAL Tids is AR Projict ≥ i i Q I . ' See"...old"for pra-revised Th�print be signed, and returned to s�cusTAR any Unauthorized�> uce sizeft of Sfigri B;add'copy to D3 d,D4: as per Ip•I , dates Address: 7301 Gail Blvd.,Zephyrhiils,FL 33541 AlcW ass may _ state agen,aes and may eK ur sdredub delays A Melon of west central signs.Inc. ` y tif 1S8+#-Y R1: Itlir APPROVED O APPROVED AS NOTED Ph 6 3WO.6763f 81a 3j98OM" 7 Date: 5-17-18 Scale: as noted wwwsignsmr neBy: si t Rx; StaNATURE DATE � cea: E • _______ I SIGNA: MONUMENT SIGN 44.4 SQ.FT.SIGN FACE AREA Scale:3/8"=1'0" One(1)double-faced illuminated monument sign required,to be installed on existing support and foundation,using new support inside sign which is sleeved into existing support—see notes with Er ill sign views at left. TOP VIEW:SIGNA 21" Existing support size to be re-used is12"steel pipe. 1T 119 SIGN A monument sign is constructed of aluminum,double-faced. �p 1a tir: 4• 4" Internal illumination by fluorescent lamps or white LED,UL approved. 0RAS NEC. _ r/2 - i81/2 Cabinet has 2"retainers. Paint white with smooth finish. Rounded end caps are separated from cabinet by vertical reveals. Horizontal and vertical reveals are blue to match logo. Face is flat clear acrylic with vinyl copy applied to second surface,backsprayed white. Exact vinyl colors to be determined. Vertical blue reveals are internally illuminated. Horizontal blue reveals are non-illuminated. Flat cut-out white address numbers,non-illuminated,are mounted to both sides of base. San Antonio t `v Vertical blue reveals Citizens Fedórah Credit Union are internally illuminated. SADDLE DETAIL M zontal blue reveals asre non-illumine ed. NEW UPPER TUBE 3/4"THICK PLATE Brick Base by Others o 4" 1"MIN. NEW HSS 8"x8"x114" l SQ STEELTUBE SUPPORT STEEL TUBE 24 i i 3/4"THICK PLATE SIZED TO FIT SNUG l INTO EXISTING PIPE STEEL ANGLE WELDED F='=="4L-- __i EXISTING LOWER TO STEEL TUBE SUPPORT PIPE APPROXIMATE , of landscaping berm,on New square steel ALUM.ANGLE FRAMING road-side of SIGNA tube sign support, BOLTED TO STEEL ANGLE ONLY,which obstructs Neeveddownirttothe SLEEVE CONNECTION DETAIL sign view existing 12"steel pipe, using ring&collar 12"existing standard wall t%tt%Uhlg4 j,,,' g pipe(extends 4"above NOTES: 6th EDITION 12017G CODE, O�pp``�PN P. H FtS' MATERIALS: (2017) • v F ALL JOINTS TO BE WELDED ALL AROUND SECTION 16 WIND LOAD,ASCE 7-10 $Q: •:� 150 MPH WIND LOAD • SCOPE OF WORK: GRADE A36 STEEL SHAPES �Z� No 7l6 RETROFIT NEW CABINET ONTO EXISTING PIPE SUPPORT. GRADE A500 B STEEL TUBE RISK CATEGORY II GRADE 6061-T6 AL.STRUCTURAL SHAPES EXPOSURE C REPLACEMENT CABINET RESULTS IN LESS LOAD APPLIED TO EXISTING SUPPORT COMPARED TO THE GRADE A325 or F593 S.S.FASTENER BOLTS TE OF EXISTING SIGN. i '• A P ,i .•`O R 1p•.• ` �,, EXISTING STEEL SUPPORT AND FOUNDATION HAVE NOT BEEN EVALUATED FOR COMPLIANCE W/THE ENCON SERVICES, INC. ��i �,����`� REQUIREMENTS OF THE FLORIDA BUILDING CODE. h 41VAl- /I� PO BOX 3613 munm��� � THIS ENGINEERING IS ONLY FOR THE ATTACHMENT OF THE REPLACEMENT SIGN TO THE EXISTING SIGN TO BE CONSTRUCTED 1O 2014 NEC 600 STANDARD APOLLO BEACH,FL 33572 NATHAN P. PRESNELL, PE 77696 SUPPORT. SIGN TO BEAR UL LABEL 813-655-3373,FLEE#9394 DATE SIGNED: 7/11/2018 SIGN TO HAVE ELECTRICAL DISCONNECT ON THE EXTERIOR CUNT APPROVAL: This drawing is Me property of SIGNSTAR ' UCB :e copy ;e as per p. S .. pre This print must be signed,dated,and returned to SIGNSTAR Any unauttwrized use is lorbiddatt. Address: 7301 Gall Blvd",Zephyrhills,FL 33541 Note:Strudwat changes may net resubnittat to third party and/or SETA state agencies and may incur schedWe de/eys- A Division of west Central Signs.Mc. 7720 U.S.H"301 N.,Tampa,Fl.33637 Dat@: 5-17-18 SCai@: 88 nlOt@d APPROVED APPROVED A8 NOTED Ph.(813)9e0-6763 Fax(813)980-6857 y www signstacnet SIGNATURE DATE FbStatatert.OES0000097 JI Location for SIGN r • Existing 8"pipe support is located at 12 setback inside property line. p No existing sign to be Location for SIGN A. Location for SIGN B. removed. Existing 8"pipe support Existing 6"pipe support Minimum sign setback is located at 12'setback is located at 15'setback iV j required is 5: inside property line. inside property line.. No existing sign to be Existing 6'X 8'sign cabinet removed, must be removed.. Q Minimum sign setback Minimum sign setback SIGN C2 Ln required is 5. required is 5. I J SIGN Cl aittiti 210'- Location for SIGN C1 Location for SIGN C2 MEDICAL ARTS (Existing 3'1"x 8'sign. (Existing 3'1"x 8'sign to be removed) to be removed) Location for SIGN B. Existing 6"pipe'support is located at 15'setback inside property line.. Existing 6'X 8'sign cabinet must be removed j Minimum sign setback required is 5. N SITE PLAN Scale:1'=50' Project: San Antonio FCU Rev.date l.niibs CUENT APPROVAL: This drawing is the property of SIGNSTAR R1:8-4-18 Reduce slze/ht of Sign B:add copy to D3&D4:all as per jp.(Si)See"...old"for pre-revised iris print must be signed,dared.and returned to SIGNSTAR Any unauthorized use forbidden. Address: 7301 Gall Blvd.,Zephyrhilis, FL 33541 dratiring. Note:$6udurai changes may require resubmiltal to third party andror SWASTAR DYII 18-3tf 1$4 4 it7 Fqe:San AntoMo FCU zt�t state agenaes and may irrcr r sdwdr4e delays A Division of west central Signs.Inc. phyrhift 7720 U.S.Hwy 301 N..Tampa.FL 33637 Date: 5-17-18 Scale: as noted APPROVED El APPROVED AS NOTED❑ Ph.(613W0-6763 Fax(813M0-6857 Si Rep: JP FL Sta a Cent.et SIGNATURE DATE FL State cert. ES0000087