Loading...
HomeMy WebLinkAbout18-20109 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20109 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION-INFORMATION Permit#:20109 Issued: 8/15/2018 Address: 37914 PRAIRIE ROSE LP LT 1 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 210,880.80 Total Fees: 8,335.79 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 8,335.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0010 CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677 Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT TOWN HOME 1,872 SQ FT APPLICATION FEES BUILDING FEE 1,191.89 ELECTRICAL FEE 246.38 PLUMBING FEE 164.25 MECHANICAL FEE 114.98 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57 FIRE INSPECTION FEES 12.50 FIR LAN REVIEW FEES 52.10 I 46 lnsp4ations Required FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney, before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS S( NATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday,August 16, 2018 1:23 PM To: Jacqueline Boges Subject: [FATHOM] Re: 37914 Prairie Rose 1p bp#20109 ##- Please type your reply above this line -## Your request (#233858) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhilisfl.zendesk.com/hc/­­­requests/233858 ............. .............................- ........... ............... ........................... ............ ............ Jose Canez (City of Zephyrhills Support Aug 16, 10:23 AM MST I have created account#000092 5820-3118629 1 have created JlRA to get property mapped. once property is mapped i will create meter install order. Best Regards, Jose C. I FATHOM Support ........... ............. -.1................................ ............... .......... ............................ ...........-............ ................ .............................. ........... .................. Jacqueline Boges Aug 15, 1 :21 PM MST 37914 prairie rose 1p bp#201 09 water, sewer, water meter This email is a service from City of Zephyrhills Support Bailey Contracting-37914 Prairie Rose Lp-1,872 sq ft Column Es SO. FEET PRICE MAIN OR LIVING: 1,872 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 210,880.80 FEE SHEET $ 1,095.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,191.90 ELECTRICAL: $ 246.38 PLUMBING: $ 164.25 MECHANICAL: $ 114.98 SUB-TOTAL $ 1,717.50 TOTAL $ 1,717.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 52.10 INSPECTION TOTAL: $ 12.50 PERMIT TOTAL TOTAL: $ 64.60 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,909.23 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 1,657.00 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,335.79 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday,August 15,2018 4:22 PM To: Jacqueline Boges Subject: [Request received]37914 Prairie Rose 1p bp#20109 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this-email or click the link below: https://zephyrhillsfl.zendesk.com/hc/"­­requests/23.3858 ............. .......... ................. .........................---............ ........... ............. .......... Jacqueline Boges Aug 15, 1 :21 PM MST 37914 prairie rose 1p bp#201 09 water, sewer, water meter This email is a service from City of Zephyrhills Support Bailey Contracting 37914 Prairie Rose Lp. 1,872 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: , 1,872 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 210,880.80 FEE SHEET $ 1,095.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,196.90 ELECTRICAL: $ 246.38 PLUMBING: $ 164.25 MECHANICAL: $ 114.98 SUB-TOTAL $ 1,722.50 Public Fee 1% TOTAL $ 1,722.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,849.63 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 1,657.00 55 and over 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,276.19 15-26-21-0210-00000-0010 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 11, 2018 Parcel ID 15-26-21-0210-00000-0010 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land $4,447 38930 BUTTERFIELD LN Building $0 ZEPHYRHILLS FL 33542-1677 Extra Features $0 Physical Address 37914 PRAIRIE ROSE.LOOP ZEPHYRHILLS, FL 33542 Just Value $4,447 Assessed (Non-School Amendment 1) $4,447 Legal Description (First 4 Lines) See Plat for this Taxable Value $4,447 Subdivision WALNUT GROVE TOWNHOUSES PB 69 PG 054 LOT 1 OR 6544 PG 1916 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) � -----------4--_.,-Ate _._—e.—.��_R____ Line Use ;Description Zoning Units IType Price ;Condition LValue 1 — 01001 SFR ; MPUD , 2,750.00 SF $1.56 1.00 I $4,290� 2 � . 0100 SFR j MPUD j 3,147.00 SF r j $0 05 j— 1.00 1 $157- Additional Land Information Acres ; 0.14 [Tax Area 30ZH t FIEMA Code X Residential Code WGTHLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line Description Year are ~��-LLUnits ��— 'Value No Extra Features Sales History Previous Owner: N/A Month/Year ;Book/Page Type lDOR Code sCondition Amount 08/2005��T 6544 / 1916 . Warranty Deed Vacant�_ $600,000 11/1981 1157 / 1702 Vacant j $130,000 01/1973 0707/ 0675 Vacant , $0 http://search.pascopa.com/parcel.aspx?parcel=2126150210000000010 8/13/2018 t PASCO: COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name Lp n -Control#' ' Count Parcel No. I5 Z6—Z(-�b ZGO— � Y � � SubDiv: t' 3 791 -. IrtuY�2 Rase LP L?`Address/Location Classiticationrrype of Use `rfU n 4; TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined Impact Fee Amount / Zone No. TAZ:$. ��i�� SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [� Yes ❑ No How Determined PARKS AND RECREATION FEE- Land-Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 76 q-v,(, " Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes, ❑ No How Determined Total Amou RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL.BE ISSUED OR FINAL INSPECTION n: PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE t. BEEN PAID AND RECEIPTED•FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. I DATE RECEIVED BY RECEIPT NO. DATE BY i t: PASCO COUNTY P� t . DEVELOPMENT SERVICES -S'G 8731 Citizens Drive Date: 12/19/2018 COUNTY FLORIDA New Port Richey,FL 34654 (Ji ri:Sr.c s.:Ytauav;rPtnracs:._.........;.::.:_;-.. 727-847-2411 NOT A PER Receipt#: 1817589 FEE DESCRIPTION 'ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee,Residential Solid 24503100-329010 2.00 1412783 $3.38 $3.38 1817589 12/19/18 ':}'�" ' ..Waste.Condo,Multi-Family MH in Park,per Unit 1526210210000000010 NAD 0060. TOTALS: $3.38 $3.38 Receipt#, Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid �,!1817589 Check:,• 20529 534 BCCCP15W 12/19/2018 $3.38 Total Payments: $3.38 ',: ., , Pa or•. ..-. Address Phone BAILEY CONTRACTING .'PERMIT VS 20108,20109 ZHLLS 2rr069-= 4 PIZ± FE�-RAvE �LP�LT . i �ARIRIE ROSE Comments: . '1526210210000000060 152621021000000010 ,+ While you wiii be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by First Billing payment services. 7. 'r ?i • �zr +-''--. "MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1 Sine le Famrn11 Dwelhn P lan RevievcT Cornnients: 1: FYI. te 'bemnin - f8"abovethoad:elevation'and an engineered site plan. :•no e 2.. Lots shah be graded.to.comply with R401.3 of the F.B.C: 3.: Compaction nest required:if'24,,.or more:of-f ll dint is.brought-in:at any.one place. . 4. Tie in survey required before pouring concrete.' 5.: Driveways require a R.D.W. use permit:; All.4:sides of.diivewa -thru the sidewalk shall-have. Y 'expansion material:. . . setbacks.shall be inet.: 7. All.property markersshall be-uncovered and ma*6d at time of first,inspection: 8 :All.A.D.A.-requirements-shall be met.:'. 9. No,electric;plumbing,:mechanical; orfrairiing shall be covered without an inspection and :approval-first. 10. All Garages shall comply:with:section R302:6 of the:F.B:C::(Fire Separation)., 11:;Appliances:shall not=be installed in:a location where subject to niechanical'damage unless protected by approved barriers. M303-.4 of the F.B.C. 12. Water heaters shall_comply:with section:P607.3 of the F.B.C.- 13. Foundation supports for.A/C.units.shall be raised-at least Y.above finished grade.. M 1308.1. 14. Return-air in all::bedrooms.T.B.C. .M.1620.4;; 15: Smoke detectors'are to be installed:in accordance:with R313:.1 of the:F.B.C. 16. All glazing requirements ere:.to be in accordance with R308.4 of the.RB:C. 17. All means.of egress are to:be iwaccordance with R3 I Y 6f the RB.C. :: 18. "Green gypsum board"sliali not be used:as.a backer_iti:showers or tubs. R702:4:2.F B.C. 19. Combination-fypeAFCi breakers.are.requited,at all locations-requiring.anAFCl.type breaker: 20: Carbon inonoxide.alarms will.be required in.new:construction.that uses fossil-buming,heating or appliances or an* attached garage:. They shall be.iristalled in accordance with.the P.B.C. . 21. A,11 plumbing mechanical,:and electrical shall lie separate from unit to unit: -This includes all. = uhde rgrowid.plumbing and electric: 22.. A112016:N,E C: Codes:wil be enforced 23: Ter-Resistant Receptacles in accordance with 406:11 of the 2016 NEC 24: lri accordance:.ivith the Sand:Development:Code;:lots.shall be.sodded before final at least 10.. . feet around:the structure.:: . . 25. Blower door test and blown in.insulation card shall be provided before C.O..: . 26 A cohy ofthe energy caclsshall be with Permit at all tinier; 27.' Cony of final insulation-report shall be:provided:with:permit before:finaiL F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code bt'Edition R.O.W-Ri t ofWa A:D..A.-Americans with.Disabilities Act : ME:C.-:-National Electric Code'(2011.) 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 37914 PRAIRIE ROSE LP LT 1 Owner: BUTTERFIELD MOBILE HOME SVC INC ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677 Parcel: 15-26-21-0210-00000-0010 Work Type: 105-NEW CONST/MULTI 5+ UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20109 Date: 1/08/2019 ISSUE BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20112 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - - LOCATION INFORMATION Permit#:20112 Issued: 8/15/2018 Address: 37912 PRAIRIE ROSE LP LT 2 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 188,012.85 Total Fees: 8,170.79 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 8,170.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0020 CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542 Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT TOWN HOME 1,669 SQ FT APPLICATION FEES BUILDING FEE 1,079.69 ELECTRICAL FEE 221.63 PLUMBING FEE 147.75 MECHANICAL FEE 103.43 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 52.10 FIRE INSPECTION FEES 12.50 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57 FIRE IMPACT FEE 273.00 POLICE IMPACT FEE 254.00 PUBLIC SAFETY 5% 26.35 1 i 50 1� Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday,August 16, 2018 1:38 PM To: Jacqueline Boges Subject: [FATHOM] Re: 37912 Prairie Rose Lp by#20112 ##- Please type your reply above this line -## Your request (#233870) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/233870 ..................................................................................................................................................................................................................................................................................................................................................................................... E Jose Canez (City of Zephyrhills Support ) L :_____. Aug 16, 10:37 AM MST I have created account#0000925820-0031 18644 1 have created JIRA to get property mapped. once property is mapped i will create meter install order. Best Regards, Jose C. I FATHOM Support ............................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges - Aug 15, 1 :27 PM MST 3 791 2 Prairie Rose Lp by#201 12 water , sewer, water meter This email is a service from City of Zephyrhills Support . 1 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday,August 15, 2018 4:28 PM To: Jacqueline Boges Subject: [Request received] 37912 Prairie Rose Lp Op#20112 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zei)hyrhillsfl.zendesk.com/hc/requests/233870 .........................--.............. ................... ........... ...............- ................ ....................................................................................... ............. Jacqueline Boges Aug 15, 1 :27 PM MST 37912 Prairie Rose Lp bp#2011 2 water , sewer, water meter This email is a service from City of Zephyrhills Support i Bailey Contracting 37912 Prairie Rose Lp. 1,669 sq ft o umn Es SQ. FEET PRICE MAIN OR LIVING: 1,669 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 188,012.85 FEE SHEET $ 985.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,084.70 ELECTRICAL: $ 221.63 PLUMBING: $ 147.75 MECHANICAL: $ 103.43 SUB-TOTAL $ 1,557.50 Public Fee 1% TOTAL $ 1,557.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,684.63 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ T I F'S: $ 1,657.00 55 and over 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,111.19 15-26-21-0210-00000-0020 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 11, 2018 Parcel ID 15-26-21-0210-00000-0020 .(Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land $4,290 38930 BUTTERFIELD LN Building $0 ZEPHYRHILLS FL 33542-1677 Extra Features $0 Physical Address 37912 PRAIRIE ROSE LOOP ZEPHYRHILLS, FL 33542 Just Value $4,290 Assessed (Non-School Amendment 1) $4,290 Legal Description (First 4 Lines) See Plat for this Taxable Value $4,290 Subdivision WALNUT GROVE TOWNHOUSES PB 69 PG 054 LOT 2 OR 6544 PG 1916 Jurisdiction City of Zephyrhills __ _ Land Detail (Card: 001 of 001) _ Line i �Us�Descriptio�rrZoning jU_ nits Type 'Price 'Condition ;Value. 1 T 0100 ( SFR —j MPUD j 2,750.00 SF 1 $1.56 j 1.00 11 $4,290 Additional_Land Information _ ITax Area{ 30ZH I FEMA�� Acres 0.06 X Residential Code GTHLPI �� I f Code ---�W�� Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _Extra Features (Card: 001 of 001) Line _ _ Description � � ear _ jUnits �rt_ i 'Value �„ No Extra Features Sales History Previous Owner: N/A Month/Year -{-Book/Page _ Type IDOR Code_ Condition� ount 08/2005 I `6544 / 1916 Warranty Deed T Vacant s $600,000 11/1981 _i 1157 / 1702 Vacant 1$ 0,000 01/1973 ( 0707/ 0675 I Vacant 0 i http://search.pascopa.com/parcel.aspx?parcel=2126150210000000020 8/13/2018 PASCO COUNTY, FLORIDA Permit No. t Date Permitted Builder Name/Owner Name JGa L�Control#' County Parcel No, J�?�- Z��.- ZD SubDIV: Address/Location /9l Z l ai�'i Classificationrrype of Use wy)`l _ TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: ? Exempt ❑Ves ❑ No How Determined Impact Fee Amount $. f; 65 7 Zone No. TAZ: Gc; }r SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ �' .(057) Mobile Home (058) Other Residential 123) Collection Fee Exempt E]Yes ❑No How Determined PARKS AND RECREATION FEE, Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑ Yes ❑ No How Determined LIBRARY FEE z.; Land Account Land Credit Land Total X. Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount �— RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION t. PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Single _Family Dwelling:: Plan-Review Comments . . 1. F.F:E. shall be:a:minimum-of 8"_above.the road elevation and an engineered.site.plan. . I. Lotsshall be graded.to.comply with R401.3 of the F.B.C. 3. ;Compaction.test required if 24" or more:of ,fill dirt is brought in'at any one place. 4:. :Tie in survey required before'pounng concrete.' 5. Driveways require a R.O.W, use permit: All 4:sides of driveway thru the-sidewalk shall have. expansion material:. :. . 6. All setbacks.shall be met... 7.: ;All property markers shall be-uncovered and marked at time of first.inspection: 8:- :All A.D.A. requirements.shall be met.: . 9. No:electric,plumbing,-mechanical; or framing shall be covered without an inspection and approval first. . 10. A11 Garages shall;comply:.with:section R302.6 of the:F.B:C:;(Fire Separation). 11:Appliances.shall'not:be installed in:a location'where subject to mechanical damage unless. 1?rotected.bY1?p a roved barriers. M303..4 o£the F.B.0 .. . . .- 12. Water heaters shall comply with section:P607.3 of the.F:B.C: 13. Foundation supports for-A/C-units.shall be raised at least 3" above finished grade. M1308.1. 14. Return air in All bedrooms.F.B.C. 1MI1620.4._ . 15: Smoke detectors are to b-e installed:in accordance with:R313:1 of the:F.B.C. 16: All glazing requirements are to be in accordance with R308.4_'of the F.B.C.-. 17.All means,of egress are o.be in:accordance with R311.of the F.B.C. 18.;`.`Green gypsum board shall-not be used as a backer.in showers or tubs. R702.442 F.B.C. 19. Combination-type A.FCI breakers are.required,at all.locations requiring.an AFCLtype breaker: 20. Carbon monoxide.alarms"Will be required in new construction that uses fossil-burning heating :or appliances or an attached garage. ;They shall be,installed in accordance with.the F.B.0 21. All plumbing, mechanical and.electrical shall:be separate from unit to.unit- This includes all undergroundplumbingand electric: 22. All 2016.N.E C. Codes will be enforced.. • . 23: Tamper- Resistant Receptacles in accordance with 406:11- of the 2016 N.E:C 24.Ah accordance:.with the Land:Development Code,lots shall be-sodded before final at least10 feet around:the structure. .. : _ 25. Blower door:test and blown in insulation card shall be provided before C:.O. 26 A copy ofthe energy cacls.shall be with permit.at all times. 27 Cony of final insulation report shall be:provided with:yerniit�before TnaL F.F:E.-Finished Floor Elevation F:B.C=Florida Building:Code 6 h Edition R.O.W.-Right of Way A-D.A.-Americans with Disabilities'Act , : N.E.C.-National Electric Code(2011) CM OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 37912 PRAIRIE ROSE LP LT 2 Owner: BUTTERFIELD MOBILE HOME SVC INC ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542 Parcel: 15-26-21-0210-00000-0020 Work Type: 105-NEW CONST/MULTI 5+ UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20112 Date: Q � -31 06/2019 ISSUED BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO-ISSUANCE ^� . PASCO COUNTY PAS DEVELOPMENT SERVICES C 8731 Citizens Drive Date: 12/19/2018 ` ;COUNTY FLOItIDA' New Port Richey, FL 34654 OPEN SPric s.GSae�,tiT I'>1'+c:Es:��� � 727-847-2411 NOT A PERMIT Receipt#: 1817599 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 2.00 1412796 $3.38 $3.38 1817599 12/19/18 . Waste Condo, Multi-Family MH in Park, per Unit 1526210210000000030 AND:1526210210000000020. TOTALS: $3.38 $3.38 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1817599 Check ,;,. ',; 20529 534 BCCCPI5W 12/19/2018 $3.38 Total Payments: $3.38 :•vor; Address Phone BAILEY CONTRACTING ; PERMIT VS 20113,20112 " ZHLLS 20113=37910 PRAIRIE ROSE LP LT 3 - '12=37912-PRAIRIE ROSE L C`t tr Comments- , 1: .:1526210210000000030, •`.' ° •'.. 1526210210000000020•, whlle you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services., i5 'yi i t ; •^ 1.'t W : ;;,Myfteports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20111 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20111 Issued: 8/15/2018 Address: 37906 PRAIRIE ROSE LP LT 5 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 188,012.85 Total Fees: 8,170.79 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 8,170.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0050 CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677 Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT TOWN HOME 1,669 SQ FT APPLICATION FEES BUILDING FEE 1,079.69 ELECTRICAL FEE 221.63 PLUMBING FEE 147.75 MECHANICAL FEE 103.43 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 52.10 FIRE INSPECTION FEES 12.50 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 I? Inspections Require , FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. fw I CONTRAC ORS IGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Bailey Contracting-37906 Prairie Rose Lp 1,669 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 1,669 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 188,012.85 FEE SHEET $ 985.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,079.70 ELECTRICAL: $ 221.63 PLUMBING: $ 147.75 MECHANICAL: $ 103.43 SUB-TOTAL $ 1,552.50 TOTAL $ 1,552.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES' PLANS TOTAL: $ 52.10 INSPECTION TOTAL: $ 12.50 PERMIT TOTAL TOTAL: $ 64.60 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,744.23 PARK IMPACT FEES $ 769.56 i SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ T I F'S: $ 1,657.00 99%1 $ 1,640.43 1% $ 16.57 TOTAL: $ 8,170.79 Jacqueline Boges From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday,August 16, 2018 1:35 PM To: Jacqueline Boges Subject: [FATHOM] Re: 37906 Prairie Rose 1p bp#201 11 ##- Please type your reply above this line -## Your request (#233868) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhillsfl.zendesk.com/hclrequests/233868 ..................... .................. ........... ............. ............. ....................................... ............... ............... Jose Canez (City of Zephyrhills, Support Aug 16, 10:35 AM MST I have created account#0000925820-0031 18639 1 have created JIRA to get property mapped. once property is mapped i will create meter install order. Best Regards, Jose C. I FATHOM Support .............. ...............1.1-...........-.11.................-.................................-................................. ............. ...........................-............................................... ................................................ ............................................. Jacqueline Boges Aug 15, 1 :25 PM MST 37906 Prairie Rose 1p bp#201 11 water, sewer, water meter This email is a service from City of Zephyrhills Support Jacqueline Boges Fnmro: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday,August 15 20184:26rw To: Jacque|meuogoa Subject: [Request received] 37gO0 Prairie Rose|pbn#2O111 ## Please type your reply above this line -## Hello Jacqueline 8oges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: ...................--_--'__................_-___' .........._ ............-__...................--_-.........................- ...........--............ -.............'-_............................'__-............. ----_ °a-� r�ueline Bog~~ - ' ^ Aug lS, 7 :25 PM MST 37906 Prairie Rose |pbc#20lllwater, sewer, water meter - - This email ise service from City ofZephyrhiUs Support . 1 Bailey Contracting 37906 Prairie Rose Lp. 1,669 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 1,669 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 188,012.85 FEE SHEET $ 985.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,084.70 ELECTRICAL: $ 221.63 PLUMBING: $ 147.75 MECHANICAL: $ 103.43 SUB-TOTAL $ 1,557.50 Public Fee 1% TOTAL $ 1,557.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,684.63 . PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 1,657.00 55 and over 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,111.19 15-26-21-0210-00000-0050 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 11, 2018 Parcel ID 15-26-21-0210-00000-0050 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land $4,290 38930 BUTTERFIELD LN Building $0 ZEPHYRHILLS FL 33542-1677 Extra Features $0 Physical Address 37906 PRAIRIE ROSE LOOP ZEPHYRHILLS, FL 33542 Just Value $4,290 Assessed (Non-School Amendment 1) $4,290 Legal Description (First 4 Lines) See Plat for this Taxable Value $4,290 Subdivision WALNUT GROVE TOWNHOUSES PB 69 PG 054 LOT 5 OR 6544 PG 1916 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) Line _ Use Description_iZoning U in is �T p Price 'Condit not ValueY�_ 1 r j 0100 SFR MPUD 2,750.00 �� SF ; $1.56� 1:00 $4,290 Additional Land Information -- — - j^FEMA---��_---- i — - Acres 0.06 Tax Area 30ZH I X Residential Code WGTHLPI f t Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line (Description Year �JUnits _ lValue No Extra Features Sales History Previous Owner: N/A Month/Year ,Book/Page _ Type 'DOR Code Condition Amount 08/2005 E 6544 / 1916 _~ Warranty Deed I Vacant $600,000 11/1981 _1157 / 1702 _Vacant_ $130,000 01/1973 ( 0707/ 0675 j Vacant $0 _ http://search.pascopa.com/parcel.aspx?parcel=2126150210000000050 8/13/2018 PASCO COUNTY, FLORIDA Permit No. .2—0 Date Permitted — Builder Name/Owner Name � ► L LC Control#• County Parcel No. SubDiv: t;(xc� 'ilt�bl^G Address/Location 3 ( l C)b o r LT '5 Classification/Type a of Use 6(,(A 07v2 YP TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: w. Exempt ❑'Yes ❑ No How Determined Ktl . . Impact Fee Amount $ 7 Zone No. TAZ: ?z; SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑ No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No. How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By r Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owneron notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 37906 PRAIRIE ROSE LP LT 5 Owner: BUTTERFIELD MOBILE HOME SVC INC ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677 Parcel: 15-26-21-0210-00000-0050 Work Type: 105-NEW CONST/MULTI 5+ UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20111 Date: 3/06/2019 O'de. 6v- ISSUE"Y: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE PASCO COUNTY ` DEVELOPMENT SERVICES �. PRSC �- 8731 Citizens Drive Date: 12/19/2618 OIJNTY FLORIDA New Port Richey, FL 34654 OPEN Sp.,km.T im-t-,r Pixms.'. : 727-847-2411 �+c�r !\B OT A 1 i ** - ` Receipt#: 1817593 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 2.00 1412789 $3.38 $3.38 1817593 12/19/18 Waste Condo,Multi-Family MH in Park,per Unit 1526210210000000050 AND`1626210210000000040. TOTALS: $3.38 $3.38 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid `la 1817593. Check 20529 534 BCCCP15W 12/19/2018 $3.38 Total Payments: $3.38 Pa or, Address Phone :`.`.:BAILEYCONTRACTING'' : PERMIT WS 20110,20111 ZHLLS -3-7 20110= 20111=37906 P IRIE ROSE LP Comments: 1526210210000000040 1526210210000000050,: While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by .First Biliing payment services.: „.�.,sir :_'t-' ' • 1 a•_ - ol 1 ' '��� -_ a fi.l� '�i �.' �. '�; III.,� • MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1 ing e ami y we ing Plan Review Comments: 1: RRE. shall be a minimum of.8" above.the road elevation:and an engineered site plan. 2. -Lots shall be graded to,comply with R4013 of the F.B.C. . 3. -Compaction:test required.:if 24" or more of-fill dirt is.brought in:at any one place: 4: Tie in survey required before pouring concrete. 5. Driveways:require a R.O:W,use permit. All 4:sides'of driveway thru the sidewalk shall have. expansion material: 6. All setbacks shall be inet:. . 7. 'All property markers shall be uncovered and'marked at time of first 'inspection: 8:. :All A.D.A. requirements.shall be met. . ...9. No:electric.plumbing,.mechanical, .or framing shall be covered without an:inspection and approval first. . .. 10. All Garages shall comply:.with:section R302:6.of the F.B.C.,(Fire Separation).: 11::Appliances shall'not:be installed in.a location where subjectto.mechanical damage unless protected'by approved:barriers-. M303.4 of the F.B:C- 12. Water heaters shall comply with section.P607.3 of the F.B.C: 13. Foundation supports:for A/C.units shall be raised at least 3'.' above finished grade, M 1308.1. 14. Return air in all,bedrooms.F.B.C. M.1620.41 15: Smoke detectors are to be installed.in' accordance:with:R3111 of-theT.B.C. 16: All glazing requirements are to be in accordance with R308.4 of the.F.B.C. 17. All means.of egress are to:be in:accordante with R311::of the F.B.C. 18. `.`Green gypsum board"shall not be used:as a backer.in:showers or tubs. R702.4.2_F.B.C. 19..Combination-type AFCI breakers are required at all.locations requiring an AFCLtype breaker: - 20. Carbon monoxide alarms will be required in.new:construction that uses fossil-burninggli'ting :or appliances or an attached garage. They shall be.installed in accordance with.the F.B.C. = 21. All plumbing,mechanical, and:electrical shall:be.separate from unit.to unit: This includes all . underground:plumbing and electric: 22. All 2016:N.E.C. Codes will be enforced:. .23. Tamper- Resistant Receptacles in accordance with 4Q6.1 I.of the 2016 N.E:C . : .24. In accordance.with the Land.Development.Code, lots.shall be sodded before final at least 10 feet around the structure. - 25. Blower door:test and blown in insulation card shall be provided before C.O. 26 A come of the energy eacls.shall be with permit-at all dihi s. 27. Copy of final insutatioir report shall be:tirovided with:permit before:final F.F.E.-Finished Floor Elevation .:. F.B.0 Florida Building Code 6a'Edition. R.O.W.-Right of Way A.D.A.-Americans-with Disabilities Act N.E:C.-National-Electric Code-(2011) 1 CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 37908 PRAIRIE ROSE LP LT 4 Owner: BUTTERFIELD MOBILE HOME SVC INC ZEPHYRHILLS, FL. 38930 BUTTERFIELD N Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677 Parcel: 15-26-21-0210-00000-0040 Work Type: 105-NEW CONST/MULTI 5+ UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20110 Date: a 3/ 6/2019 e &� --- - iFl� 92��� ISSUED BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20110 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION._-.'__ - __� LOCATION INFORMATION: Permit#:20110 Issued: 8/15/2018 Address: 37908 PRAIRIE ROSE LP LT 4 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 188,012.85 Total Fees: 8,170.79 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 8,170.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0040 CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD N ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677 Phone: (813)377-7395 , Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT TOWN HOME 1,669 SQ FT APPLICATION FEES BUILDING FEE 1,079.69 ELECTRICAL FEE 221.63 PLUMBING FEE 147.75 MECHANICAL FEE 103.43 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3%4,, 473.78 FIRE INSPECTION FEES 12.50 FIRE PLAN REVIEW FEES 52.10 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57 Inspections Required F OTER 2ND ROUGH PLUMB Misc INSULATION E LING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney. before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS 9IGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Bailey Contracting-37908 Prairie Rose Lp-1,669 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 1,669 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 188,012.85 FEE SHEET $ 985.00 ADDRESS $ 30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 1,079.70 ELECTRICAL: $ 221.63 PLUMBING: $ 147.75 MECHANICAL: $ 103.43 SUB-TOTAL $ 1,552.50 TOTAL $ 1,552.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 52.10 INSPECTION TOTAL: $ 12.50 PERMIT TOTAL TOTAL: $ 64.60 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,744.23 PARK IMPACT FEES $ 769.56 ' I SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ T I F'S: $ 1,657.00 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,170.79 Jacqueline Boges From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday, August 16, 2018 1:27 PM To: Jacqueline Boges Subject: [FATHOM] Re: 37908 Prairie Rose Lp by#20110 ##- Please type your reply above this line -## Your request (#233863) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/233863 ............................................... .............................................................................................................................................................................................................................................................................. .................................................. Jose Canez (City of Zephyrhills Support ) ` -- ' Aug 16, 1 0:27 AM MST I have created account#0000925820-0031 1 8634 1 have created JIRA to get property mapped. once property is mapped i will create meter install order. Best Regards, Jose C. I FATHOM Support ................................................................................................................................. ................................................................................................................................................................................................................................. i Jacqueline Boges Aug 15, 1 :23 PM MST 37908 Prairie Rose Lip by#201 10 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday, August 15, 2018 4:24 PM To: Jacqueline Boges Subject: [Request received] 37908 Prairie Rose Lp by#20110 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephvrhilisfl.zendesk.com/hc/requests/233863 .................................................................................................................................................................................................................................................................................................................................................................................. { Jacqueline Boges L - - Aug 15, 1 :23 PM MST 37908 Prairie Rose Lp by#201 10 water, sewer, water meter This email is a service from City of Zephyrhills Support . i Bailey Contracting 37908 Prairie Rose Lp. 1,669 sq ft Column El SQ. FEET PRICE MAIN OR LIVING: 1,669 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ VALUATION $ 188,012.85 FEE SHEET $ 985.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,084.70 ELECTRICAL: $ 221.63 PLUMBING: $ 147.75 MECHANICAL: $ 103.43 SUB-TOTAL $ 1,557.50 Public Fee 1% TOTAL $ 1,557.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,684.63 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ T I F'S: $ 1,657.00 55 and over 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,111.In9 15-26-21-0210-00000-0040 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 11, 2018 Parcel ID 15-26-21-0210-00000-0040 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land $4,290 38930 BUTTERFIELD LN Building $0 ZEPHYRHILLS FL 33542-1677 Extra Features $0 Physical Address 37908 PRAIRIE ROSE LOOP ZEPHYRHILLS, FL 33542 Just Value $4,290 Assessed (Non-School Amendment 1) $4,290 Legal Description (First 4 Lines) See Plat for this Taxable Value $4,290 Subdivision WALNUT GROVE TOWNHOUSES PB 69 PG 054 LOT 4 OR 6544 PG 1916 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) � Use escriptionZ ype— CLine g Un onditionValue 1 0100 SFR MPU 2,750.00 j SF $1.556 1.00 $4,290 Additional Land Information Acres i FEMA 0.06 ITax Area 30ZH I Cod ^X Residential Code WGTHLPI _ I Building Information - Use 00 - Unimproved (Card: 00.1 of 001) Unimproved Parcel 00 - Unimproved _ _ Extra Features (Card: 001 of 001) Line _ _ Description 'Year — _ Units_ jValueu —_ No Extra Features Sales History Previous Owner: N/A Month/Year ok/Page —jType - DOR Code Condition Amount T 08/2005 �_ 6544 /_1916 _Warranty Deed Vacant $600 000 11/1981 1157 / 1702 Vacant $130,000 01/1973 � 0707/ 0675^—I~T-�--�---�__ -_Vacant 0 http://search.pascopa.com/parcel.aspx?parcel=2126150210000000040 8/13/2018 ASCO COUNTY, FLORIDA Permit No. ' 2D-11D Date Permitted Builder Name/Owner Name 434,1eq Control#' County Parcel No. �5 7�—b2ca—� D nY� SubDiv: . zi :..;, Address/Location 3 790r1��ar� IVJ�2 Classification/Type of Use f U w�le- f TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: /, Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. i 65 7 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 76f 66 e:•. Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amou RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner,on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Single.family.Dwelling Plan Review Comments 1.' RRE. shall be a-minimum- of.8" above the road.elevation and an engineered.site plan. . 2. Lots shall be graded to.comply with R401.3 of the F.R.C. _ p. 3. ;Compaction est required.if 24 or more:of fill dirt is.brought in:di ariy one place: 4: Tie in survey required before pouring concrete. 5. Driveways:require-a'R.O.:W, use permit: All 4:sides of driveway thru the sidewalk shall have. expansion matenal:. 6.. All setbacks.shall be met.: 7. All.property:markers shall be_uncov - d and marked at time of first.inspection: - .8.. All A.D.A.requirements.shall be met.:- 9.. No:electric;plumbing,.mechanical, or framing shall be covered without an:inspection and approval first. 10.All Garages shall-comply.with-section R302:6-of the F.B.C.-(Fire $6 aration). 11.Appliaaces'shall not:be installed in-a location where subject to.mechanical damage unless P.rotected.by approved barrier s. M303.4 of.the RB.0 _ 12. Water heaters shall comply'with sectiona607.3 of the F.B.C: 13. Foundation supports-for'A/C.units shall be raised at least 3" above finished-grade.. M1308.1 14. Return air in all.:bedrooms.F.B.C. Ml620.4.. - 15. Smoke detectors are to-be installed:in acc6rdance.with:R313:1 of theT.B.C. 16::All glazing requirements are.to be-in accordance with R308.4,of the F.B:C. . 17. All means of egress are'to be in:accordanbe with R3IYof the F.B.C. 18. `.`Green gypsumboard"-shall not be'-used:as.a backer.in':showers or tubs.'R702.4.2.F.B.C. 19. Combination-type AFCI breakers are required,at all locations requiring.an AFCLtype breaker. 20. Carbon monoxide alarins will.be required in new:construction-that uses fossil-burning heating' . :or appliances or an attached garage:..They shall be.installed in accordance with,the F.B.C: 21. All plumbing,mechanical, and.electrical shall be separate from unit to:unit. This:includes all. . underground plumbing and electric: 22. All 2016.N.E.C. Codes Will'be enforced. 23:_Tamper=Resistant Receptacles in accordance with 406:11 of the-2016 NEC ..24-Ah accordance.With the Land Development:Code;lots.shall be-sodded before final at least 10 feet around the structure. :. 25.Blower door test and blown in insulation card shall be providedbefore C.O. 26 A copy ofthe energy caclsshall be with pern:it.at all times= 27 Copy of final insulation report shall be:provided.with perMit before:rnab . F.F.E.-Finished Floor Elevation FB.C-Florida Building Code 6th Edition R.O.W.-Right of Way. A.D.A:-Americans With Disabilities Act N.E.C.-.National Electric Code (2011) PASCO COUNTY ':,__ s F* DEVELOPMENT SERVICES 8731 Citizens Drive Date: 12/19/2018 ' COUNTY: FLORIDA New Port Richey, FL 34654 727-847-2411 ** NOT A PERMIT ** Receipt* 1817593 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE s,'I• , ' :.`a Impact Fee Residential Solid .24503100-329010 2.00 1412789 $3.38 $3.38 1817593 12/19/18 Waste Condo,Multi-Family MH ' in Park, per Unit 1526210210000000060 AND,1526210210000000040. ' TOTALS: $3.38 $3.38 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amf Paid 1817593 . Check 20529 534 BCCCP15W 12/19/2018 $3.38 Total Payments: $3.38 Pavor •' Address Phone BAILEY,CONTRACTING.'' 4' 'ti PERMIT#'S20 929 ' L__tS 2t3410='A7Q08 PRAIR1F.AeG =•'• 20111=37906 PRAIRIE ROSE LP Comments: 1526210210000000040 1526210210000000050 •,'j •'`,While you will be paying your bill with Pasop,COunty Development services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. ly`r:, • I; MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1 is g. e Faml y Dwe in g _ n Plan Review Comore is I. F.F.E. shall be a minimum_of 8 above the road.elevation and an engineered site,plan. 2. Lots..shall be graded.to.comply with R401.3 of the'F.B:.C: .3. ;Compaction test required if 24 or more.of fill dirt is.brought_in:at any one place. 4: Tie in' survey required before pouring concrete. 5. Drive ways:require a R.O:W. use permit.: All 4:sides of driveway thru the sidewalk shall have expansion material:. 6. All setbacks.shall,be met.:. . 7._ All property:markers shall be_uncovered and marked at time of first inspection: . I. .8:. :All A.D.A:requirements shall be met. . 9.: .No electric;plumbirig,_mechanicaL.or framing shall be covered without an.inspection and approval first.. . 10. All;Garages shall:complymith-section R302:6-of the:F.B.C::(Fire S:eparation). -11.Appliances:shall not be installed in.a location where subjectto.mechanical damage:unless. pfotected-by approved barriers. M303'.4 of the F.B.0 12. Water heaters shallcomply:with section P607.3 of the F.B.C: 13. Foundation supports for.A/C units shall'b'eraised at least 3"above finished grade, M1308.1. 14. Return air in all:bedrooms. F.B.C. M1620,4, 15. Smoke detectors are to be installed in accordanee.with R313:1 of the F.B.C. 16::A11 glazing requirements-are:.to b.e in accordance with R308.4.of the F.B.C. . 17. All means.of egress are to be in accordance with-R311`of the F.B.G. 18. "Green gypsum.board" shall-not be used as.a backer in:showers or-tubs. R702:4:2-F.B.C: 19.-Combination-typeAFCI breakers.are,required at all.locations requiring an AFCI,type breaker: 20: Carbon monoxide.alarms.will be required in.new:construction that uses fossil-burning heating or appliances or an attached garage: They shall be,installed in accordance with the F.B.C. .21. All plumbing,mechanical,-and electrical shall be separate from unit to.unit: This includes all. un ergroun p urnbin acid electric: 22. All 2016:N.E:C: Codes Will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N:E:C 24. In accordance.With the Land:.Development.Code, lots shall be.sodded before final of least 10 feet "around the structure. 25. Blower door test and blown in insulation card shall be provided before C.-O. 26.A copy ofthe energy cacls.shall be with permit-at-all times .27.. Copy of final insulation report shall be:provided with:perihut before:fnaL F.F.E.-Finished Floor.Elevation F.B.C-Florida Building Code 6 h Edition R.O.W.-Right of Way A.D.A:-Americans with Disabilities Act N.E.C.-.National Electric Code(2011) CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20108'� BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION- LOCATION INFORMATION Permit#:20108 Issued: 8/15/2018 Address: 37904 PRAIRIE ROSE LP LT 6 Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 210,880.80 Total Fees: 8,335.79 Subdivision: WALNUT GROVE TOWNHOMES Amount Paid: 8,335.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0060 CONTRACTOR INFORMATION OWNER INFORMATION Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677 Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT TOWN HOME 1,872 SQ FT APPLICATION FEES BUILDING FEE 1,191.89 ELECTRICAL FEE 246.38 PLUMBING FEE 164.25 MECHANICAL FEE 114.98 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 52.10 FIRE INSPECTION FEES 12.50 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1%_ 16.57 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 S� Inspections Required FOOTER 2ND ROUGH PLUMB Misc I INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC, MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your.failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday,August 16, 2018 1:20 PM To: Jacqueline Boges Subject: [FATHOM] Re: 37904 Prairie Rose Lp bp#20108 Please type your reply above this line -## I Your request (#233855) has been updated. REPLY TO THIS EMAIL or click the link below: htti)s://zephyrhilisfl.zendesk.com/hc/"­­reciuests/233855 ...........--............. ............. ............. ............................ .......... ................-................. ............ ............. Jose Canez (City of Zephyrhills Support ) Aug 16, 10:19 AM MST I have created account#0000925820-00311 8624 1 have created JIRA to get property mapped. once property is mapped i will create meter install order. Best Regards, Jose C. I FATHOM Support ..................I.............-.................I-............I...................... ....................................................- .. ..................... .............. ............ ..........— ...... Jacqueline Boges Aug 15, 1 :19 PM MST 37904 prairie rose 1p bp#201 08 water, sewer, water meter This email is a service from City of Zephyrhills Support Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday,August 15, 2018 4:20 PM To: Jacqueline Boges Subject: [Request received] 37904 Prairie Rose Lp by#20108 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/233855 .................................................................................................................................................................................................................................................................................................................................................................................... I . Jacqueline Boges - ' Aug 15, 1 :19 PM MST 37904 prairie rose Ip by#20108 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 Bailey Contracting-37904 Prairie Rose Lp-1,872 sq ft o umn Es SQ. FEET PRICE MAIN OR LIVING: 1,872 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 210,880.80 FEE SHEET $ 1,095.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,191.90 ELECTRICAL: $ 246.38 PLUMBING: $ 164.25 MECHANICAL: $ 114.98 SUB-TOTAL $ 1,717.50 TOTAL $ 1,717.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 4,73.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 52.10 INSPECTION TOTAL: $ 12.50 PERMIT TOTAL TOTAL: $ 64.60 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,909.23 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 1,657.00 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,335.79 Bailey Contracting 37904 Prairie Rose Lp. 1,672 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 1,872 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 210,880.80 FEE SHEET $ 1,095.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,196.90 ELECTRICAL: $ 246.38 PLUMBING: $ 164.25 MECHANICAL: $ 114.98 SUB-TOTAL $ 1,722.50 Public Fee 1% TOTAL $ 1,722.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,849.63 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 1,657.00 55 and over 99% $ 1,640.43 1% $ 16.57 TOTAL: $ 8,276.19 15-26-21-0210-00000-0060 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 11, 2018 Parcel ID 15-26-21-0210-00000-0060 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value BUTTERFIELD MOBILE HOME Ag Land $0 SERVICE INC Land $4,373 38930 BUTTERFIELD LN Building $0 ZEPHYRHILLS FL 33542-1677 Extra Features $0 Physical Address 37904 PRAIRIE ROSE LOOP ZEPHYRHILLS, FL 33542 Just Value $4,373 Assessed (Non-School Amendment 1) $4,373 Legal Description (First 4 Lines) See Plat for this Taxable Value $4,373 Subdivision WALNUT GROVE TOWNHOUSES PB 69 PG 054 LOT 6 OR 6544 PG 1916 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use Description!Z_oning 1Units jType Orice Condition a_ue- 1 �_ 0100 SFR MPU 2 750.00 SF i $1.56—1.00 $4,290 2 0100 SFR MPUD j 1,650.00 SF $0.05 i 1.00 $83 _Additional Land Information Acres 0.10 ]Tax Areal 30ZH I FEMA X I Residential Code WGTHLPI I Code I j Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _Extra Features (Card: 001 of 001) Line J bescription Year Umts Value _ _ _ _-.-- _-_._._1 �_—._..__ No Extra Features Sales History Previous Owner: N/A Month/Year (Book/Page Type _ ,DOR Code Condition Amount 08/2005 6544 / 1916 �1 Warranty Deed Vacant $600,000 4 11/1981 1157 / 1702 ^� Vacant ! $130,000 01/1973 T 0707/ 0675 j. j�— — # Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126150210000000060 8/13/2018 Permit No. 26 Date Permitted S L� ��ff��Control y�e ~Builder Name/Owner Name � r l(Iy, �- _ County Parcel No. ��J-26 2(—j}2 �t3—CX �t�O(o0 SubDiv: b7GC tS1�(?fC Address/Location tt�'r ClassificatlaM'ype of Use -;. TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: P�Z` ..: Exempt C]Yes ❑ No How Determined Impact Fee Amount $. .057 0 Zane No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ _ (057) Mobile Home r` (058) Other Residential 123) Collection Fee Exempt [�] Yes Q No How Determined PARKS AND RECREATION FEE, Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation //Total Zone TOTAL AMOUNT $ �rPIS� Exempt [1 Yes n No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes No How Determined Total Amount`=j—/— RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By 5 NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY i Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY PASCO COUNTY pA 1 DEVELOPMENT SERVICES 8731 Citizens Drive Date: 12/19/2018 ',:COUNTY' FLORIDA New Port Richey, FL 34654 E�PEN SP:1crs".Vi»nnti r Pt�lchs.,., "`: 727-847-2411 * T A PERMIT Receipt#: 1817589 FEE DESCRIPTION .ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid_ 24503100-329010 2.00 1412783 $3.38 $3.38 1817589 12/19/18 Waste Condo,Multi-Family MH in Park, per Unit. 1526210210000000010 NAD 0060. TOTALS: $3.38 $3.38 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1817589 Check 20529 534 BCCCP15W 12/19/2018 $3.38 Total Payments: $3.38 Pa or Address Phone ;.BAILEY CONTRACTING PERMIT#'S 20108,20109 ZH 201004 RR/IR�E ROSE I P I T F 20109=37914 PARIRIE ROSE LP LT 1 Comments: 1526210210000000060 152621021000000010 d While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by •�:`" :"First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1 Sin le Famil IDwelhn g : Y g Pla n Review.Comments - 1. RF.. shall be.a.minimum:of.8"above the road.elevation and an engineered site plan. . 2.. Lots shall be graded.to.comply with R401.3 of the F.B:.C: 3.: Compaction test required if 24" or more of fill dirt is brought in:at any one place: 4. Tie in survey required-before pouring concrete. :..5. Driveways require a R:Q.:W:use permit:. All 4:sides of driveway thru the sidewalk sha..11 Have. :expansion n mateal:. 6.: All setbacks shall be'met.: 7. :All.property markers shall be uncovered and marked at time of first.'inspection: 8: :All A.D.A.requirements shall be met.: . 9.. No:electric.plumbing, mechanical; or framing sha11 be:covered without an.inspection and approval first. . 10. All.Garages shall comply_with section R3016,of.the F.B.C.::(Fire Separation). 11:Appliances:shall'not:be installed in a location where siibjectto mechanical damage unless. :protected:by approved,barriers. M3014 of.the F.B.C. i2. Water heaters shall,comply with sectionT607.3 of the F.B.C: 13. Fomdatiori supports:for.A/C units shall be raised at least 3 above finished grade.. M1309.1 14.Return air in.all.-bedrooms.F.B.C. Ml620.4._ 15. Smoke detecfors are.to be iristalled:in' accordance.-With.R313:1-of-the-F.B.C. 16: All glazing requirements are to be in-accordance'with R308A of the F.B.-C. 17. All means.of egress are to:be in:accordance with R311 of the F.B.C.. :: 18. `.`Green gypsum.board shall-not be used as.a backer.iw R7024. :2.F.B.C. 19..Combination-type AFCl breakers_are.required at all locations requiring an AFCI,type breaker: 20. Carbon monoxide.alarms will be required in.new:construction that uses-fossil-burning heating :. :or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shallbe separate from unit to.unit. This includes all. . undergrourid plumbingand electric: - 22. All 2016.N.E.C. Codes:will.be enforced:.' .23.Tamper=Resistant Receptacles in accordance with 40611 of the 2016 N.E:C 24. In accordance:With.the Land.Development Code;_lots shall be sodded before final at least 10 feet around'the structure. : 25. Blower door test and blown in insulation card shall be provided before C.O. - 26 A copy of.the enem cacls shall be with Permit at all times.. 27. Cony of findl insulation report shall be provided with:Permit before.Tnal F.F.E.-Finished Floor Elevation F B.C- Florida Building Code 6fl'Edition R.O.W.-Right of Way A:D:A:=Americans with.DisabilitiesRct N.E.C.-.National Electric Code(2011) CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 37904 PRAIRIE ROSE LP LT 6 Owner: BUTTERFIELD MOBILE HOME SVC INC ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677 Parcel: 15-26-21-0210-00000-0060 Work Type: 105-NEW CONST/MULTI 5+ UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20108 Date. 3/06/2019 C ISSUED Y: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE I IIIIII IIIII lllll lllll llill 111111111111111111111111111111111 2018119856 Permit No. Parcel ID No !S= 2(o- 21. OZ/d OOC 60 6600 NOTICE OF COMMENCEMENT State of FlOr dA County of Aaj C 0 THE UNDERSIGNED hereby gtves mortice that improvement wffl be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencenw t : 1. Description of Property. Parcel identification No. /S-2!O-Z/-, Q VO •00 coo-cogo Street Address3y9N137912, 379/0,337?08i379P, 7664•3794y_ ralire Pak L.oe) 2. General Description of Improvemerd�Q y/ :Cn S Tr U C- 0A �7 (0 UAl 1 a n h o M tv G q`f Jr-4;1,j' FL 3354+2 3. Owner Information or, information t the Lessee cmdracted for the"improvement 6lr Yt 'Od hoo-lol fj In e- 3M 25 /�`iin`e.-/GQ 12.4 Daide q(-� F L State Interest in Property: OWA C/ Name of Fee simple Titleholder. (If different from Owner Fisted above) Address T . City state 4. Contractor o e'r 41 yZ 40 f T-c// QI Z A 4P—A' b FL —�— p 2 State CCwb woes Telephone No.: 6 13 -7a ' S. Surety:A( A Naffie" Address City State Amount of Bond: $ Telephone No.: 6. Lender.IV Name Address City State Landels Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City Stale Telephone Number of Designated Per=r. 6. In addition to himself;the owner designates of to receive a copy of the lienols Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the e)#ration dale may not be before the completion of construction and final payment to the contractor,but wW be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. U my gpri� ry I declare that 1 have read the foregoinlef. g notice of commencement and that the fads stated therein are true to the best STATE OF FLORIDA COUNTY OF PASCO Signature of OwrmlYr lessee,or Owners or L s Authorized Rcpt:1974519 Rec: 10.00 OfrrcerroiraaodPartner/Manager DS: 0.00 IT: 0.00 07/17./2018 J. R. , DPtY Clerk � signat ��ysT The foregoing Instrument was admowlad before me this-,(_ y of 4 20 L by urn P4 Id t _ (type of .e.g.,offkw,trustee,attorney in fad)for `J 0 MAT, namy 9f parlyonbehafrof 0 tWInstrument wasenecutel Produced Identification❑ Notary Sig— Ida LL,-,[!!- r'-cation Produced Name(Print) ��i7X/- � .X-(a•>/,�r;' UJI A y t� PAULA 6.0'NEIL,Ph.D.PASC0 CLERK & COMPTROLLEk 07/27/2018 02:21 m 1 of .1 F�,,. OR BK 975..1 PG 377r�4 . J�JJJlJJJf11t11t11�� '. dt STATE OF FLORIDA, COUNTY OF PASCO THIS FOREGOING IS A COPY OF THE DOCUMENT TRUE AND CORRECT In(Fodli, ON I OR OF PUBLIC RECORD IN THIS OFFICE WIT NKIVIYHAND AND A OFFICIAL SEA L LcTHtIS DAY OF 188 PAUSM O'NEI C4RK&�MPTROLLE yR DEPUTY CLERK 4 OF o l5u" I,l:fl P I Il P City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: JAG Date Received: Site: 371W, 37�-e-8` Permit Type: 'Tam ��- e Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ i This 7comm?en;tsheps 1 be kept with the permit and/or plans. Kalvin Swit;(er—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0718366 Unit 8-2 to 8-5 Builder Name: Butterfield Street: 4408 Court St Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL,33542 Permit Numbec"JI06 bi P f? Owner: "Typical"-Interior-Units 8-2 thru 8-5 Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(640.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 453.33 ft2 b.Frame-Wood,Adjacent R=13.0 186.67 ft2 3. Number of units,if multiple family I c.NIA R= ft2 4. Number of Bedrooms 2 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1267.0 sqft.) Insulation Area a.Under Attic(Vented) R=38.0 1267.00 ft2 6. Conditioned floor area above grade(ft2) 1267 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(47.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:ah 6 175 a. U-Factor: Dbl,U=0.30 47,00 ft2 SHGC: SHGC=0.25 b. U-Factor: N/A ft2 12,Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 23.6 SEER:14.50 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Strip Heat 17.1 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 2.957 ft. Area Weighted Average SHGC: 0.250 14.Hot water systems 8. Floor Types (1267.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1267.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits CF,Pstat Glass/Floor Area: 0.037 Total Proposed Modified Loads: 35.04 PASS Total Baseline Loads: 35.25 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this = z 0 Code. calculation indicates compliance s 9 fz Z a mac„ & - 60-4 with the Florida Energy Code. J PREPARED BY: Before construction is completed DATE: 07-19-18. this building will be inspected for compliance with Section 553.908 k- I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFlr.IAI ;, DATE: [DATE: - 9±/-L-)V 44 - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3-2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). 7/19/2018 10:40 AM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: R0718366 Unit 8-2 to 8-5 Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1267 Lot# Owner Name: 'Typical'-Interior-Units 8-2 t Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: Butterfield Rotate Angle: 0 Street: 4408 Court St Permit Office: City of Zephyrhills Cross Ventilation: No County: Pasco Jurisdiction: 611600 Whole House Fan: No City,State,Zip: Zephyrhills, Family Type: Single-family FL, 33542 New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI , 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire Unit 1267 10136 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Master Bedroom 186 1488 No 2 1 1 Yes Yes Yes 2 Mwic 34 272 No 0 1 Yes Yes Yes 3 Master Bath 93 744 No 0 1 Yes Yes Yes 4 Wit 23 184 No 0 1 Yes Yes Yes 5 Great Rm Dining 343 2744 No 0 1 Yes Yes Yes 6 Kitchen 180 1440 Yes 0 1 Yes Yes Yes 7 - Den 105 840 No 0 1 Yes Yes Yes 8 Bedroom2 139 1112 No 1 1 1 Yes Yes Yes 9 ah 11 88 No 0 1 Yes Yes Yes 10 Bath2 50 400 No 0 1 Yes Yes Yes 11 Utility 30 240 No 0 1 Yes Yes Yes 12 Entry 73 584 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Master Bedroom 30 ft 0 186 ftZ ---- 0 1 0 2 Slab-On-Grade Edge Insulatio Mwic 1 ft 0 34 ftz ---- 0 1 0 3 Slab-On-Grade Edge Insulatio Master Bath 1 ft 0 93 ftZ ---- 0 1 0 4 Slab-On-Grade Edge Insulatio Wit 1 ft 0 23 ftZ ---- 0 1 0 5 Slab-On-Grade Edge Insulatio Great Rm Dining 13 ft 0 343 ftz ---- 0 1 0 7/19/2018 10:40 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio Kitchen 1 ft 0 180 ft2 0 1 0 7 Slab-On-Grade Edge Insulatio Den 1 ft 0 105 ft2 __-- 0 1 0 8 Slab-On-Grade Edge Insulatio Bedroom2 loft 0 139 ft2 ____ 0 1 0 9 Slab-On-Grade Edge Insulatio ah 1 ft 0 11 ft2 ---- 0 1 0 10SIab-On-Grade Edge Insulatio Bath2 1 ft 0 50 ft2 ____ 0 1 0 11SIab-On-Grade Edge Insulatio Utility 1 ft 0 30 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio Entry 3.7 ft 0 73 ft2 ---- 0 1 0 ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Composition shingles 1335 ft2 210 ft2 Medium N 0.65 No 0.9 No 0 18.4 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1267 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Master Bedroom 38 Blown 186 ft2 0.1 Wood 2 Under Attic(Vented) Mwic 38 Blown 34 ft2 0.1 Wood 3 Under Attic(Vented) Master Bath 38 Blown 93 ft2 0.1 Wood 4 Under Attic(Vented) Mtlt 38 Blown 23 ft2 0.1 Wood 5 Under Attic(Vented) Great Rm Dining 38 Blown 343 ft2 0.1 Wood 6 Under Attic(Vented) Kitchen 38 Blown 180 ft2 0.1 Wood 7 Under Attic(Vented) Den 38 Blown 105 ft2 0.1 Wood 8 Under Attic(Vented) Bedroom2 38 Blown 139 ft2 0.1 Wood 9 Under Attic(Vented) ah 38 Blown 11 ft2 0.1 Wood 10 Under Attic(Vented) Bath2 38 Blown 50 ft2 0.1 Wood 11 Under Attic(Vented) Utility 38 Blown 30 ft2 0.1 Wood 12 Under Attic(Vented) Entry 38 Blown 73 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below nrnt To Wall Type1 N Exterior Concrete Block-Ext InsMbster Bedro 5 12 8 8 0 101.3 ft2 0 0 0.2 0 2 E Exterior Concrete Block-Ext Infthster Bedro 5 8 8 8 0 69.3 ft2 0 0 0.2 0 3 W Exterior Concrete Block-Ext InSdhster Bedro 5 8 8 8 0 69.3 ft2 0 0 0.2 0 4 N Exterior Concrete Block-Ext InGdeat Rm Din 5 13 0 8 0 104.0 ft2 0 0 0.2 0 7/19/2018 10:40 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 5 S Exterior Concrete Block-Ext InsdBedroom2 5 10 0 8 0 80.0 ft2 0 0 0.2 0 6 S Exterior Concrete Block-Ext Insul Entry 5 3 8 8 0 29.3 ft2 0 0 0.2 0 7 S Garage Frame-Wood Entry 13 11 4 8 0 90.7 ft2 0 0.14 0.2 0 8 S Garage Frame-Wood Den 13 12 0 8 0 96.0 ft2 0 0.14 0.2 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Great Rm Din None .35 3 6 8 20 ft2 2 S Insulated Entry None .35 3 6 8 20 ft2 3 S Insulated Entry None .35 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 TIM Low-E Double Yes 0.3 0.25 N 15.0 ft2 1 ft 0 in 1 ft2 in Drapes/blinds Exterior 5 2 N 4 TIM Low-E Double Yes 0.3 0.25 N 12.0 ft2 8 ft 8 in 1 ft 2 in Drapes/blinds Exterior 5 3 S 5 TIM Low-E Double Yes 0.3 0.25 N 20.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 240 ft2 240 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 1013.6 55.65 104.65 .1117 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 17.06 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:14.523.6 kBtu/hr 708 cfm 0.75 1 sys#1 7/19/2018 10:40 AM EnergyGaugeg)USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 50 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 75 ft2 Default Leakage ah (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma rl Jun Jul rl Au rl Se Oct Nov Dec Heatin f X�Jan f X�Feb Mar APr f May Jun Jul AuSep Oct Xj Nov HDec Ventin [ Jan [ Feb X Mar A r [ Ma Jun Jul Aug Se [X Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Master Bedroom Default(8 Ibs/sq.ft. ft2 ft 0.3 Mtlt Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath Default(8 lbs/sq.ft. ft2 ft 0.3 Mwic Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom3 Default(8 Ibs/sq.ft. ft2 ft 0.3 ah Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Entry Default(8 lbs/sq.ft. ft2 ft 0.3 Hall Default(8 Ibs/s .ff. ft2 ft 0.3 Great Rm Dining 7/19/2018 10:40 AM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*• 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location ah 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 23.6 a)Split system SEER 14.5 5. Is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1267 d) Room unit/PTAC EER e)Other 7.Windows,type and area a)U-factor:(weighted average) 7a. 0.300 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 17.1 c)Area 7c. 47.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete, raised(R-value) 9c. a)Electric resistance EF 0.97 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 5.0 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 13.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11. Ceiling type and insulation level a)Ceiling fans Yes a)Under attic 11a. 38.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: 4408 Court St City/FL Zip: Zephyrhills, FL 33542 7/19/2018 10:41:49 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Manual S Compliance Report Job: R0718366 wrightsoft9 Date: 07-19-18 Entire Unit By: TMN Bahr's Propane Gas &AC Inc 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 Project • • For: "Typical'- Units 8-2 thru 8-5 4408 Court St, Zephyrhills, FL 33542 Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 16608 Btuh Entering coil DB: 81.5°F Outdoor design WB: 77.2°F Latent gain: 4003 Btuh Entering coil WB: 65.1°F Indoor design DB: 75.0°F Total gain: 20610 Btuh Indoor RH: 50% Estimated airflow: 787 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: Goodman or Eqv. Model: GSX140241L+ASPT33C14A Actual airflow: 787 cfm Sensible capacity: 17700 Btuh 107% of load Latent capacity: 5900 Btuh 147% of load Total capacity: 23600 Btuh 115% of load SHR: 75% Heating Equipment Design Conditions Outdoor design DB: 42.9°F Heat loss: 10518 Btuh Entering coil DB: 67.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Elec strip Manufacturer: Model: Actual airflow: 261 cfm Output capacity: 5.0 kW 162% of load Temp. rise: 59 OF Meets all requirements of ACCA Manual S. wrightsotV, 2018-Jul-19 10:37:22 ^t .,.,..-, .�».-.,* , Right-Suite®Universal 2018 18.0.19 RSU07440 Page 1 AC+K ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: 5 Project Summary Job: R0718366 wrig 1tsQf Date: 07-19-18 Entire Unit By: TMN Bahes Propane Gas &AC Inc 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 Project ! • For: "Typical"- Units 8-2 thru 8-5 4408 Court St, Zephyrhills, FL 33542 Notes: Load Calculation was obtained from an on-site inspection. Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 7755 Btuh Structure 8625 Btuh Ducts 2763 Btuh Ducts 4911 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 3072 Btuh Piping 0 Btuh Equipment load 10518 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 16608 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2773 Btuh Ducts 1230 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ftz) 1267 1267 Equipment latent load 4003 Btuh Volume(W) 10135 10135 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 20610 Btuh Equiv.AVF(cfm) 76 39 Req. total capacity at 0.75 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Goodman or Eqv. Trade Elec. Heat Trade Split AC Model Cond GSX140241 L AHRI ref Coil ASPT33C14A AHRI ref 8655537 Efficiency 100 EFF Efficiency 12.0 EER, 14.5 SEER Heating input 5.0 kW Sensible cooling 17700 Btuh Heating output 17061 Btuh Latent cooling 5900 Btuh Temperature rise 59 OF Total cooling 23600 Btuh Actual air flow 261 cfm Actual air flow 787 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.058 cfm/Btuh Static pressure 0 in H2O Static pressure 0.50 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -pp- wrlo!n Im- 2018-Jul-19 10:37:22 �- •-w-• Right-Suite®Universal 2018 18.0.19 RSU07440 Page 1 ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S -P�t-wrightsof- Right-JO Worksheet Job: R0718366 Entire Unit Date: 07-19-18 Bahr's Propane Gas &AC Inc By: TMN 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Entire Unit Master Bedroom 2 Exposed wall 56.7 ft 30.0 ft 3 Room height 8.0 ft d 8.0 ft heat/cool 4 Room dimensions 12.7 x 14.7 ft 5 Room area 1266.9 ft' 185.8 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.126 n 3.39 2.47 ' 205 1M 536 391 lot 66 292 213 4AS-2ob 0.300 n 8.13 8.01 12 0 98 96 0 0 0 0 4A5-2ob 0.300 n 8.13 8.01 15 0 122 120 15 0 122 120 11N0 0.350 _n_ -- -9.48 ,.10.83 ,-.20 20 191 .--,-- -",218 -- 0 0 _ -- 0 - 0 11 W 13A-5ocs_ 0.125 a 3.39 _ 2.47 69 69 _ 235 171 69 69 _ _ 235 _ _ 171 13A-5ocs 0.125 s 3.39 2.47 109 69 235 171 0 0 0 0 4A5-2ob 0,300 s 8.13 8.18 20 17 163 164 .0 0 0 0 11NO 0.350 s 9.48 _ 10.83 20 20_ 191 218 -0 0_ 0 0 W 13A-5ocs 0.125 w 3.39 2.47 - 69 69 235 171 69 69 235 171 PII - 12C-0sw 0.091 - 2.47 1.46 -. _203 185 456 270 0 0 0 0 r....D _11N0 0.350 ..n- .---_-.9.48 -- _10.83---.- _ -18___, . 18 169�---___194 -. _ --0 _-_--_ 0 _ 0_-._.... 0 P 12C-0sw _ 9.991.0 2.47 1.46 99 99 243 144 0 0 0 0 - - -. - _ C . _ 16B-30ad„ " _. "-_ "-__._0.032 .. _ ___.0.87_,. 1.74 __._1267 :_ :1267 ."_1099___ 2207, 186 "-"_- -186 _161 . 324 F 22A-tpl .,.. 0,989 _.26.80 . ._0.00__ __1267.._ -_57 1,519. Q .._._ .186 __-._30 __ 80.4 0 6 c)AED excursion 0 -4 Envelope loss/gain 5490 4534 1849 996 12 a) Infiltration 2265 701 1199 371 b) Room ventilation 0 0 0 0 13 1ntemal gains: Occupants @ 230 3 690 2 460 Appliances/other 2700 0 Subtotal Qines 6 to 13) 7755 8625 3048 1827 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 7755 8625 3048 1827 15 Duct loads W%l 57%1 2763 4911 36% 57% 1086 1040 Total room load 10518 135361 4135 2867 Air required(cfm) 261 787 103 167 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w1rao lmim- 2018-Jul-19 10:37:22 AWk Right-Suite®Universal 2018 18.0.19 RSU07440 Page 1 ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S -I' -wrightsoft Right-M Worksheet Job: R0718366 Entire Unit By: 07-19-18 By: TMN Bahr's Propane Gas&AC Inc . 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Mwic Master Bath 2 Exposed wall O ft O ft 3 Room height 8.0 ft heat/cool 8.0 ft heaticool 4 Room dimensions 1.0 x 33.7 ft 1.0 x 92.6 ft 5 Room area 33.7 ftz 92.6 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft5 Load number (Btuh/ftl°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5o6s_ - -0.125 n 3.39' 2.47 0 0 0- 0 0 0 0 0 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 11N0 0.350 __n _9.48 --10.83 .0 .0 0 --0 -,-- -- 0 _ _0 0_ _.- 0 11 w 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3,39 2.47 0 0 0.._ - 0 0 0 0 0 4AS-2ob 0.300 s 8.13 8.18 0 0 0 0 0 0 0 0 11NO 0.350 s` 9.48 10.83 0 0 0 0 0 0 0 0 w__ ,13A-5ocs -- - -0.125 w 3.39 2.47_ -- - P 12C-Osw 0.091 2.47 1.46 0 0 0 0 0 0 0 0 D,-11N0 _._ .. .. _. _-.- -_--- 0.350 ...n._ _ .__9.48 _.10.83-. '_ _--0 - _ .-- - 0 ... ._-0--=--- .0..-._.-. -0- _O_---_-- 0 _--__ 0 P 12C-Osw 0.091 2.47 1.46 C_ 0 0 0 0 0 _ 0 0 0 16B�Oad. _ ---0.032 -. _ __0.87..:_--_1.79 _-___ 34 ._34... 29 - 59 .. 93 93- 80_ - -161 22A-tpl- - --- 0.969 -26.80 ---0.00- - 34 -0 - __0- -0 .._. 93 --0 . . 0 _ .- . 0- 6 c)AED excursion 0 0 Envelope loss/gain 29 59 80 161 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 29 59 80 161 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 29 59 80 161 15 Duct loads 36% 57% 10 33 36% 57% 29 92 Total room load 40 92 j j 109 j 253' Air required(cfm) 1 5 3 15 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -r w wrigEttsoft- 2018-Jul-19 10:37:22 Right-Suite@ Universal 2018 18.0.19 RSU07440 Page 2 ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJB Building Front faces: S +wrightsoft- Right-JO Worksheet Job: R0718366 Entire Unit Date: 07-19-18 Bahr's Propane Gas&AC Inc By: TMN 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Wit Great Rm Dining 2 Exposed wall 0 ft 13.0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 Room dimensions 3.7 x 6.3 ft 1.0 x 344.2 ft 5 Room area 23.2 ft2 344.2 ft2 Ty Construction U-value Or HTM Area (W) Load Area (ftl Load number (Btuh/ft;°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Val 13A5ocs 0.125 - n -3.39 � 2.47 0 0 0 0 rv104 72 244 178 4A52ob 0.300 n 8.13 8.01 0 0 0 0 12 0 98 96 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 11N0. - - - 0.350 n_ _.. _9.48 ._..... 10.83 --- --0 _ - -- 0 - 0- ._ -0 :_. _...20 _ .,__20.. _ 191. 218 11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0 V�J 13A-5ocs "0.1215 s 3.39 2.47 0 0 0 0 0 0 -0 0 4A5-2ob 0.300 s 8.13 8.18 0 0 0 0 0 0 0 0 11NO 0.350 s_ 9.48 _1083- .0 0 -, _0 -- -0 0 .. - 0, -0 - 0 W, .1 3A-5ocs, 0.125 w-_ _ 3.39. 2.4-7 __ 0 0 _ _ 6. _ 0 0 6 0 0 PI - 12C-Osw 0.091 - 2.47 1.46 0 0 0 0 0 0 0 0 L-DL-D 11NO 0.350 .n _9.48 .._10.83 0 . . _._. 0 -,0__, ._ _0 .. _ . 0 .._ ... -0 0_. ,. 0 P„ 12C-Osw - 0.091 _-__, _ _2.47 1.46 0 C,_ __ 16B-30ad,. _ ..__ 0.032._. ._____0.67 1.74 ._._ .23 - _ _ 23- .-_.-,.20 _._40._-_. 344__.._ 344._:..._..296__ .600 F _ 22A-01 0.989_- 26.80 _0.00 ,----23___ 0 - __.._0. - - _ ___0 .. .344 _13._.. . 348 _ -- ._ 0 6 c)AED excursion 0 -4 Envelope loss/gain 20 40 1179 1097 12 a) Infiltration 0 0 520 161 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal pins 6 to 13) 20 40 1698 2148 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20 40 1698 2148 15 Duct loads 36% 57% 7 23 360/a 57% 605 1223 Total room load 27 63 2303 3370 Air required(cfm) 1 4 57 196 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrigtatsoTt- 2018-Jul-1910:37:22 A&K Right-Suite®Universal 2018 18.0.19 RSU07440 Page 3 ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S -r�t-wrightsofta Right-M Worksheet Job: R0718366 Entire Unit Date: 07-19-18 Bahr's Propane Gas&AC Inc By: TMN 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Kitchen Den 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 1.0 x 179.9 ft 1.0 x 104.7 ft 5 Room area 179.9 ft' 104.7 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft2°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.125 n 3.39 2.47 0 0 0 0 0 0 0 0 1q�J--G 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 I-G 4A5.2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 11NO 0.350._n- _ __9.48 - -10.83 .__ 0 0 __0 _ 0-- 0 11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0 13A-5ocs . 0.125 s 3.39 - 2.47 0 0 0 0 0 0 0 0 4A5-2ob 0.300 s. 8.13 8.18 0 0 0 0 0 0 0 0 11N0. 0.350-_.s .. 9. -._._10.83 -0 0 _.. ... .0_- - 0 -0 0 0 0 W 13A-5ocs ._ ._. _. _ _9.125 _w 3.39 2.47.- -0 _ _0 -. . 0 .. 0_. 0 _ _ 0 0 0 P 12C-0sw 0.091 - 2.47 1.46 0 0 0 0 109 109 270 160 11N0, 0.350 . n- ____9.48 ._. 10.83. -,-- -0.. 0 -0 _0 _ - _. _0 _0. 0_=. 0 P 12G-Osw_ _ 0.091 .,, 2.47 __ 1.46 _-_-.,- _ 0 -_ 0 0_ 0 0 0 0 0 Q 16B-30ad-.,_; .- , __ __- 0.032_- ,_ _ _-0.87 __-_ 1.74 _ .-180 .180 156-_._ _313 105 __ 105__.. _ 91- _ __- _182 __.0.989 .-_-- _26.800.00 _-_1.80 6 c)AED excursion 4 -1 Envelope loss/gain 156 309 360 341 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 1800 0 Subtotal Vines 6 to 13) 156 2109 360 341 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 156 2109 360 341 15 Duct loads 36% 579/6 56 1201 W% 57% 128 194 Total room load 212 3310 489 536 Air required(cfm) 5 192 12 31 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wriigE�tsoft^ 2018-Jul-1910:37:22 Right-Suite@ Universal 2018 18.0.19 RSU07440 Page 4 ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S - -wrightsoft Right-.10 Worksheet Job: R0718366 Entire Unit Date: 07-19-18 Bahr's Propane Gas&AC Inc By: TMN 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Bedroom2 ah 2 Exposed wall 10.0 ft 0 ft 3 Room height 8.0 ft heaticool 8.0 ft heat/cool 4 Room dimensions 1.0 x 138.9 ft 3.3 x 3.3 ft 5 Room area 138.9 ft2 11.1 ftz Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 13A-5ocs 0.126 n 3.39 -2.47 0 0 0 6 0 0 0 0 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 'h 4A5.2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 11N0 - --, _ _ - - ----.0.350 .-n-_-__.9.48 10.83 -. _ -- -- A-- 0 0 ---0,-__-- 0. ..._ 0 0 - -0 11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0 1rN 13A-5ocs 0.125 s 3.39 Z47 80 60 203 148 0 - 0 0 0 I{---GD 4A5-2ob 0.300 s 8.13 8.18 20 17 163 164 0 0 0 0 111N[01 __...- _ - _0.350 -s_ ' 9.48 _ _10.83 - - _. 0 0 0. _ W 13A-5ocs _ 0.125_ w 3.39 __ - 2.47 0 0 0 0 0 0 _.. 0. -_ 9 PI - 12C-0sw 0.091 - 2.47 1.46 0 0 0 0 0 0. 0 0 .11N0,.__ - _0.350 .n- _.9.48 10.83 _ ._. 0 - _ ._0-- _ 0._ --%0- _- _ 0_-_- .0 0 .:_. 0 P 12C-0sw _0.091 _2.47 1.46 99 _ 99,, 243 ._ 144 0. _ C _ 16B-30ad_- - - 1 0. 0 _ --... 0.032 -- - 0.87..__. 1.74 ,-_.-_.139 13.9, .. 120 -_ --,242 . _- _11 -- __._ .f _- 16 19. F 22A-tPl_. 0.989 „26.80 - __0.00 tl_ ._.139 _ 10 268 -_--. _ 0 . . 11 0- 0 6 c)AED excursion 15 0 Envelope loss/gain 998 713 10 19 12 a) Infiltration 400 124 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 1 230 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 1397 1066 10 19 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1397 1066 10 19 15 Duct loads 36% 57% 498 607 36% 57% 3 11 Total room load 1895 1674 1 13 30 Air required(cfm) 47 97 101 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrGg[�tsoft^ 2018-Jul-19 10:37:22 Right-Suite®Universal 2018 18.0.19 RSU07440 Page 5 rove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S -P�t-wrightsoft, Right-J®Worksheet Job: R0718366 Entire Unit Date: 07-19-18 Bahr's Propane Gas&AC Inc By: TMN 4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Bath2 Utility 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat/cool 4 Room dimensions 10.0 x 5.0 ft 6.3 x 4-7 ft 5 Room area 50.0 ft' 29.6 ft2 Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 Vh 13A-Socs 0.125 n 3.39 -2.47 0 0 0 0 0 0 0 0 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0 _ . __n_.. - --9.48 10.83 _ _ .0 . .11N0 0350-_ 0 0- - -0 0 - - - 0 0 0 11 W 13A-5ocs 0.125 a 3.39 _ 2.47 0 0 0 0 0 0 0 0 yJ 13A-5ocs 0.125 s 3.39 2.47 0 0 0 _._._ _ O _ _..- 0 - 0 - - 0 0 I�(p 4A5-2ob 0.300 s 8.13 8.18 0 0 0 0 0 . .0 0 0 11NO 0.350 s .- _ -9.48 _._10.83 _ 0_ _ 0_ -_ 0 _ 0_ _ 0 W 13A-5ocs 0.125 ,w_,--- 3.39 2.47 _ 0 0 0 0 0 0 0 0 P 12C-Osw 0.091 - 2.47 1.46 0 0 0 0 0 0 0 0 11NO _ _0.350 _.n. 9.48 10.83 _ .0 - _.0_ 0 -0- - __-0 _ -0, 0- . 0 P _- - 12C-Osw-. 0.091, _- 2.47. , -. 1.46.- .- -- 0__ _..._ . Q C.. 16B-30ad -1.74 : _ 50 .... , 50 43 _87- 30 .--- ...30,-,_ -_-__26 51 F., - 224-tpl . 0.989 - _ .. _26.80 ., _ 0.00 50 0 _ 0 - _ 0 .. 30 - 0 -- -- 0 -- 0 6 c)AED excursion 0 0 Envelope loss/gain 43 87 26 51 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal pines 6 to 13) 43 87 26 51 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 43 87 26 51 15 Ductloads 36% 57% 15 50 369/6 57% 9 29 Total room load 59 136 35 81 Air required(cfm) 1 8 1 11 5 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. a -wrigE�tsott- 2018-Jul-19 10:37:22 -� ---�--• Right-Suite®Universal 2018 18.0.19 RSU07440 Page 6 ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S - -vvrightsoft' Right-JO Worksheet Job: R0718366 Entire Unit Date: 07-19-18 . Bahr's Propane Gas &AC Inc By: TMN 4441 Alen Rd,Zephyrhills,FL33541 Phone:813-782-5013 1 Room name Entry 2 Exposed wall 3.7 ft 3 Room height 8.0 ft heat/cool 4 Room dimensions 3.7 x 20.0 ft 5 Room area 73.3 ft2 Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuh/ft?°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 b 13A5ocs 0.125 n 3.39 2.47 0 0 0 04A5-lob 0.300 n 8.13 8.01 0 0 0 0 4A5-lob 0.300 n 8.13 8.01 0 0 0 0 . 11NO-.-- -.._.__0.350 _n_ ..9.48 _ 10.83-- _ ., 0 -0 __0 11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 V+J 13A-5ocs 0.125 s 3.39 2.47 ,29 9 31 23 4A5-2ob 0.300 s 8.13 8.18 0 0 0 0 11NO 0.350 -s _ 9.48 10.83_--_- 20. 20 191 __ 218 W 13A-5ocs 0.125, w. -__ 3.39 2.47- 0 6--_ 0 - P 12C-Osw 0.091 - 2.47 1.46 93 75 186 110 .11N0 - 0.350 .n - __ _9.48 10.83. -.. -18 _ 16. 169_ - _ -194 -__- P 12C-Osw - - 0.091.. -- _2.47 _..._ 1.46 ._. --0 ,. .. ._0 C. 16B-30ad 64- --B - .0.032.-' - _0.87_....1.74 - - F 22A-td - _ _- _-_0.969 _26.80 _,_0.00 _ 73_. .. . . 4 _ 98 -- 0 6 c)AED excursion -1 Envelope loss/gain 739 671 12 a) Infiltration 147 45 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 886 716 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 886 716 15 Duct loads 36% 57% 316 408 Total room load 1202 1124 Air required(cfm) 301 65 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -M wrigl%tsoTt 2018-Jul-1910:37:22 Right-Suite(E)Universal 2018 18.0.19 RSU07440 Page 7 ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S PASCO COUNTY DEVELOPMENT SERVICES 8731 Citizens Drive Date: 12/19/2018 tflIJNTy.:.FLORIDA New Port Richey,FL 34654 okl(SPUMS.V1P.R U,rr PU48. 727-847-2411 NOT A PERMIT Receipt#: 1817599 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 2.00 1412796 $3.38 $3.38 1817599 12/19/18 Waste Condo, Multi-Family MH; in Park,per Unit 1526210210000000030 AND 1526210210000000020. TOTALS: $3.38 $3.38 Receipt#:. Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1817599 Check 20529 534 BCCCP15W 12/19/2018 $3.38 Total Payments: $3.38 P_avL:.. Address Phone BAILEY CONTRACTING PERMIT## 2&143 261 �4 L 20113=37910 PRAIRIE ROSE LPJ� 20112=37912 PRAIRIE ROSE LP LT 2 Comments: 1526210210000000030 1526210210000000020. ; L y, While you.wlli be paying your bill with Pasco County Development Services,the full amount of the credit card or e•check fees,NOT shown above,Is collected by P6st-8illing payment services,;i 'i. MyReports/reports//PASCOPROD/PASC.O/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1 813-780-0020 City of Zephyrhills Permit Application Fax-813-7804°021 Building Department Date Received , -, Z 5—/ Phone Contact for P iiting Owners Name lJ� Y�� 1,(e Owner Phone Number 3 ' Owners Add csa. Owner Phone Number S Fee Simple Titlehoider Name �C^r`'r U'PS er Phone Number Fee Simple Titleholder Address �[ 3 JOB ADDRESS tr U b `�� U/�`-' �c l� �.� n- LOT# LOT# f SUB13MSION Jrtu —&YI-aa4 PARCEL ID# /e� �.� —.�_ Q v�d" 066 G2 S?C-9 Q.�C3 (06TAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR B ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE �SFR Q COMM Q OTHER TYPE OF CONSTRUCTION L�d�/ BLOCK Q FRAME Q STEEL Q DESCRIPTION OF WORK �CJu'a'`y V'#ti'r BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION i =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =r'LUMBING $ 31z =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION • (00 '� ''' JcZ.CO =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N I FEE CURREn Y/N Address License# ELECTRICIAN COMPANY67 SIGNATURE REGISTERED / N FEE CURREn I Y/N Address Q '- l License# qG 1DDt�f7� . PLUMBER ( i �//�}/��y�� COMPANY I L S •I SIGNATURE rJ c[���/"`�yy ``rr REGISTERED I YIN I FEE CURREn I Y!N Address f g G'17r C 5 Licensee# MECHANICAL / COMPANY fte SIGNATURE REGISTERED I Y/ N FEE CURREn I Y/N Address � J�� 1 eA) License# 641W V-y OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN LILN Address License# ttttltllltllllllllltttllllttllllllltltllltttltlllttttllttlltllllttl RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stomnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY required for all NEW construction. Directions: Fill our application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) " Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if an public roadways..needi ROW � . NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to restrictions" Which may The_undersigned assumes_responsibility for_compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR n the owner has hired o contractor or contractors mundertake work,they may be required to be licensed m accordance with state and local ntractor is not licensed as required by law, both the and contractor may ue cited for a misdemeanorvmopuun under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco Cvvn TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of certifyfinal power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Horneowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the Information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also ~ that.understand that the regulations..other government agencies may intended work,and that-- mv responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department o _n.'—' —_l Protection-Cypress Bay heads, Weiland Areas and Environmentally Sensitive -- Lands'Water/Wastewater Treatment ' Southwest Florida vvate, Management Dost8vt-xe||o. cnneoe Bovhaaus. Weiland Areas, Altering Watercourses. ' Army Corps o,Engineers-Seawalls,Docks,Navigable ' Department of Health & Ryhom\uoVve Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. ' uo Environmental Protection Agency-Asbestos abatement. ' Federal Aviation /understand that the following restrictions apply m the use mfill: . ' Use of fill|m not allowed m Flood Zone'Vr unless expressly pennmed. ' If the xU material is to be used in Flood Zone "A". it is understood that u drainage addressing u ^onmponoaUnovolume"Will be submitted at time nf permitting which is prepared by professional engineer licensed uy the State ofFlorida. ' If the fill material ivuomo used in Flood Zone'Km connectionwith o permittedbuilding using stem wall nonmmnUon.|certify that fill will be used only»o fill the area within the stem wall. ' /f fi|/ material is to be used in any area, | certify that use of such fill will not adversely n of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air Conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued.shall become invalid unless the wo,fk authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING To OWNER: YOUR FAILURE ro RECORD A NOTICE op COMMENCEMENT MAY RESULT|mYOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. |p YOU INTEND ro OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. Subscribed and sworn o(or affffrned)before me Via Subscribed and sworn to(Tr affirmed)before me thl by by Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced _ap identification. as identification. Notary Public Notary Public Commission No. Commission No Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped