HomeMy WebLinkAbout18-20109 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20109
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION-INFORMATION
Permit#:20109 Issued: 8/15/2018 Address: 37914 PRAIRIE ROSE LP LT 1
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 210,880.80 Total Fees: 8,335.79 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,335.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0010
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC
Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN
ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT TOWN HOME 1,872 SQ FT
APPLICATION FEES
BUILDING FEE 1,191.89 ELECTRICAL FEE 246.38 PLUMBING FEE 164.25
MECHANICAL FEE 114.98 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43
TRAFFIC IMPACT FEE 1% 16.57 FIRE INSPECTION FEES 12.50 FIR LAN REVIEW FEES 52.10
I
46
lnsp4ations Required
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney,
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS S( NATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Jacqueline Boges
From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Thursday,August 16, 2018 1:23 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 37914 Prairie Rose 1p bp#20109
##- Please type your reply above this line -##
Your request (#233858) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/233858
............. .............................- ........... ............... ........................... ............ ............
Jose Canez (City of Zephyrhills Support
Aug 16, 10:23 AM MST
I have created account#000092 5820-3118629 1 have created JlRA to get property mapped.
once property is mapped i will create meter install order.
Best Regards,
Jose C. I FATHOM Support
........... ............. -.1................................ ............... .......... ............................ ...........-............ ................ .............................. ........... ..................
Jacqueline Boges
Aug 15, 1 :21 PM MST
37914 prairie rose 1p bp#201 09 water, sewer, water meter
This email is a service from City of Zephyrhills Support
Bailey Contracting-37914 Prairie Rose Lp-1,872 sq ft
Column Es
SO. FEET PRICE
MAIN OR LIVING: 1,872 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 210,880.80
FEE SHEET $ 1,095.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,191.90
ELECTRICAL: $ 246.38
PLUMBING: $ 164.25
MECHANICAL: $ 114.98
SUB-TOTAL $ 1,717.50
TOTAL $ 1,717.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 52.10
INSPECTION TOTAL: $ 12.50
PERMIT TOTAL
TOTAL: $ 64.60
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,909.23
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: $ 1,657.00
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,335.79
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday,August 15,2018 4:22 PM
To: Jacqueline Boges
Subject: [Request received]37914 Prairie Rose 1p bp#20109
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this-email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/"requests/23.3858
............. .......... ................. .........................---............ ........... ............. ..........
Jacqueline Boges
Aug 15, 1 :21 PM MST
37914 prairie rose 1p bp#201 09 water, sewer, water meter
This email is a service from City of Zephyrhills Support
Bailey Contracting 37914 Prairie Rose Lp. 1,872 sq ft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: , 1,872 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 210,880.80
FEE SHEET $ 1,095.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,196.90
ELECTRICAL: $ 246.38
PLUMBING: $ 164.25
MECHANICAL: $ 114.98
SUB-TOTAL $ 1,722.50
Public Fee 1%
TOTAL $ 1,722.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,849.63
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: $ 1,657.00 55 and over
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,276.19
15-26-21-0210-00000-0010 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, August 11, 2018
Parcel ID 15-26-21-0210-00000-0010 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
BUTTERFIELD MOBILE HOME Ag Land $0
SERVICE INC Land $4,447
38930 BUTTERFIELD LN Building $0
ZEPHYRHILLS FL 33542-1677 Extra Features $0
Physical Address
37914 PRAIRIE ROSE.LOOP
ZEPHYRHILLS, FL 33542 Just Value $4,447
Assessed (Non-School Amendment 1) $4,447
Legal Description (First 4 Lines)
See Plat for this Taxable Value $4,447
Subdivision
WALNUT GROVE TOWNHOUSES
PB 69 PG 054
LOT 1
OR 6544 PG 1916
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
� -----------4--_.,-Ate _._—e.—.��_R____
Line Use ;Description Zoning Units IType Price ;Condition LValue
1 — 01001 SFR ; MPUD , 2,750.00 SF $1.56 1.00 I $4,290�
2 � . 0100 SFR j MPUD j 3,147.00 SF r j $0 05 j— 1.00 1 $157-
Additional Land Information
Acres ; 0.14 [Tax Area 30ZH t FIEMA Code X Residential Code WGTHLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line Description Year are ~��-LLUnits ��— 'Value
No Extra Features
Sales History
Previous Owner: N/A
Month/Year ;Book/Page Type lDOR Code sCondition Amount
08/2005��T 6544 / 1916 . Warranty Deed Vacant�_ $600,000
11/1981 1157 / 1702 Vacant j $130,000
01/1973 0707/ 0675 Vacant , $0
http://search.pascopa.com/parcel.aspx?parcel=2126150210000000010 8/13/2018
t
PASCO: COUNTY, FLORIDA
Permit No.
Date Permitted
Builder Name/Owner Name Lp n -Control#' '
Count Parcel No. I5 Z6—Z(-�b ZGO— �
Y � � SubDiv:
t' 3 791 -. IrtuY�2 Rase LP L?`Address/Location
Classiticationrrype of Use `rfU n
4; TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
Exempt ❑Yes ❑ No How Determined
Impact Fee Amount / Zone No. TAZ:$. ��i��
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [� Yes ❑ No How Determined
PARKS AND RECREATION FEE-
Land-Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 76 q-v,(,
" Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes, ❑ No How Determined Total Amou
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL.BE ISSUED OR FINAL INSPECTION
n:
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
t. BEEN PAID AND
RECEIPTED•FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same. I
DATE RECEIVED BY
RECEIPT NO. DATE BY
i
t: PASCO COUNTY
P� t .
DEVELOPMENT SERVICES
-S'G 8731 Citizens Drive Date: 12/19/2018
COUNTY FLORIDA New Port Richey,FL 34654
(Ji ri:Sr.c s.:Ytauav;rPtnracs:._.........;.::.:_;-.. 727-847-2411
NOT A PER
Receipt#: 1817589
FEE DESCRIPTION 'ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee,Residential Solid 24503100-329010 2.00 1412783 $3.38 $3.38 1817589 12/19/18
':}'�" ' ..Waste.Condo,Multi-Family MH
in Park,per Unit
1526210210000000010 NAD 0060.
TOTALS: $3.38 $3.38
Receipt#, Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
�,!1817589 Check:,• 20529 534 BCCCP15W 12/19/2018 $3.38
Total Payments: $3.38
',: ., , Pa or•. ..-. Address Phone
BAILEY CONTRACTING .'PERMIT VS 20108,20109
ZHLLS
2rr069-=
4 PIZ± FE�-RAvE �LP�LT
.
i �ARIRIE ROSE
Comments: .
'1526210210000000060
152621021000000010
,+ While you wiii be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by
First Billing payment services.
7.
'r
?i •
�zr
+-''--. "MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1
Sine le Famrn11 Dwelhn
P lan RevievcT Cornnients:
1: FYI. te 'bemnin - f8"abovethoad:elevation'and an engineered site plan. :•no e
2.. Lots shah be graded.to.comply with R401.3 of the F.B.C:
3.: Compaction nest required:if'24,,.or more:of-f ll dint is.brought-in:at any.one place. .
4. Tie in survey required before pouring concrete.'
5.: Driveways require a R.D.W. use permit:; All.4:sides of.diivewa -thru the sidewalk shall-have.
Y
'expansion material:. . .
setbacks.shall be inet.:
7. All.property markersshall be-uncovered and ma*6d at time of first,inspection:
8 :All.A.D.A.-requirements-shall be met.:'.
9. No,electric;plumbing,:mechanical; orfrairiing shall be covered without an inspection and
:approval-first.
10. All Garages shall comply:with:section R302:6 of the:F.B:C::(Fire Separation).,
11:;Appliances:shall not=be installed in:a location where subject to niechanical'damage unless
protected by approved barriers. M303-.4 of the F.B.C.
12. Water heaters shall_comply:with section:P607.3 of the F.B.C.-
13. Foundation supports for.A/C.units.shall be raised-at least Y.above finished grade.. M 1308.1.
14. Return-air in all::bedrooms.T.B.C. .M.1620.4;;
15: Smoke detectors'are to be installed:in accordance:with R313:.1 of the:F.B.C.
16. All glazing requirements ere:.to be in accordance with R308.4 of the.RB:C.
17. All means.of egress are to:be iwaccordance with R3 I Y 6f the RB.C. ::
18. "Green gypsum board"sliali not be used:as.a backer_iti:showers or tubs. R702:4:2.F B.C.
19. Combination-fypeAFCi breakers.are.requited,at all locations-requiring.anAFCl.type breaker:
20: Carbon inonoxide.alarms will.be required in.new:construction.that uses fossil-buming,heating
or appliances or an* attached garage:. They shall be.iristalled in accordance with.the P.B.C. .
21. A,11 plumbing mechanical,:and electrical shall lie separate from unit to unit: -This includes all. =
uhde
rgrowid.plumbing and electric:
22.. A112016:N,E C: Codes:wil be enforced
23: Ter-Resistant Receptacles in accordance with 406:11 of the 2016 NEC
24: lri accordance:.ivith the Sand:Development:Code;:lots.shall be.sodded before final at least 10.. .
feet around:the structure.:: . .
25. Blower door test and blown in.insulation card shall be provided before C.O..: .
26 A cohy ofthe energy caclsshall be with Permit at all tinier;
27.' Cony of final insulation-report shall be:provided:with:permit before:finaiL
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code bt'Edition
R.O.W-Ri t ofWa
A:D..A.-Americans with.Disabilities Act : ME:C.-:-National Electric Code'(2011.)
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 37914 PRAIRIE ROSE LP LT 1 Owner: BUTTERFIELD MOBILE HOME SVC INC
ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN
Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677
Parcel: 15-26-21-0210-00000-0010 Work Type: 105-NEW CONST/MULTI 5+ UNIT
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 20109
Date: 1/08/2019
ISSUE BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20112
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION - - LOCATION INFORMATION
Permit#:20112 Issued: 8/15/2018 Address: 37912 PRAIRIE ROSE LP LT 2
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 188,012.85 Total Fees: 8,170.79 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,170.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0020
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC
Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN
ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT TOWN HOME 1,669 SQ FT
APPLICATION FEES
BUILDING FEE 1,079.69 ELECTRICAL FEE 221.63 PLUMBING FEE 147.75
MECHANICAL FEE 103.43 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 52.10 FIRE INSPECTION FEES 12.50
PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57
FIRE IMPACT FEE 273.00 POLICE IMPACT FEE 254.00 PUBLIC SAFETY 5% 26.35
1
i
50 1�
Inspections Required
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Jacqueline Boges
From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Thursday,August 16, 2018 1:38 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 37912 Prairie Rose Lp by#20112
##- Please type your reply above this line -##
Your request (#233870) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/233870
.....................................................................................................................................................................................................................................................................................................................................................................................
E Jose Canez (City of Zephyrhills Support )
L :_____. Aug 16, 10:37 AM MST
I have created account#0000925820-0031 18644 1 have created JIRA to get property mapped.
once property is mapped i will create meter install order.
Best Regards,
Jose C. I FATHOM Support
...............................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
- Aug 15, 1 :27 PM MST
3 791 2 Prairie Rose Lp by#201 12 water , sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday,August 15, 2018 4:28 PM
To: Jacqueline Boges
Subject: [Request received] 37912 Prairie Rose Lp Op#20112
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zei)hyrhillsfl.zendesk.com/hc/requests/233870
.........................--.............. ................... ........... ...............- ................ ....................................................................................... .............
Jacqueline Boges
Aug 15, 1 :27 PM MST
37912 Prairie Rose Lp bp#2011 2 water , sewer, water meter
This email is a service from City of Zephyrhills Support
i
Bailey Contracting 37912 Prairie Rose Lp. 1,669 sq ft
o umn Es
SQ. FEET PRICE
MAIN OR LIVING: 1,669 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 188,012.85
FEE SHEET $ 985.00
ADDRESS $ 40.00
DRIVEWAY1 $ 40.00
BUILDING: $ 1,084.70
ELECTRICAL: $ 221.63
PLUMBING: $ 147.75
MECHANICAL: $ 103.43
SUB-TOTAL $ 1,557.50
Public Fee 1%
TOTAL $ 1,557.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,684.63
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $
T I F'S: $ 1,657.00 55 and over
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,111.19
15-26-21-0210-00000-0020 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, August 11, 2018
Parcel ID 15-26-21-0210-00000-0020 .(Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
BUTTERFIELD MOBILE HOME Ag Land $0
SERVICE INC Land $4,290
38930 BUTTERFIELD LN Building $0
ZEPHYRHILLS FL 33542-1677 Extra Features $0
Physical Address
37912 PRAIRIE ROSE LOOP
ZEPHYRHILLS, FL 33542 Just Value $4,290
Assessed (Non-School Amendment 1) $4,290
Legal Description (First 4 Lines)
See Plat for this Taxable Value
$4,290
Subdivision
WALNUT GROVE TOWNHOUSES
PB 69 PG 054
LOT 2
OR 6544 PG 1916
Jurisdiction
City of Zephyrhills
__ _ Land Detail (Card: 001 of 001)
_
Line i �Us�Descriptio�rrZoning jU_ nits Type 'Price 'Condition ;Value.
1 T 0100 ( SFR —j MPUD j 2,750.00 SF 1 $1.56 j 1.00 11 $4,290
Additional_Land Information _
ITax Area{ 30ZH I FEMA��
Acres 0.06 X Residential Code GTHLPI
�� I f Code ---�W��
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_Extra Features (Card: 001 of 001)
Line _ _ Description � � ear _ jUnits �rt_ i 'Value �„
No Extra Features
Sales History
Previous Owner: N/A
Month/Year -{-Book/Page _ Type IDOR Code_ Condition� ount
08/2005 I `6544 / 1916 Warranty Deed T Vacant s $600,000
11/1981 _i 1157 / 1702 Vacant 1$ 0,000
01/1973 ( 0707/ 0675 I Vacant 0
i
http://search.pascopa.com/parcel.aspx?parcel=2126150210000000020 8/13/2018
PASCO COUNTY, FLORIDA
Permit No.
t Date Permitted
Builder Name/Owner Name JGa L�Control#'
County Parcel No, J�?�- Z��.- ZD SubDIV:
Address/Location /9l Z l ai�'i
Classificationrrype of Use wy)`l
_ TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
? Exempt ❑Ves ❑ No How Determined
Impact Fee Amount $. f; 65 7 Zone No. TAZ:
Gc;
}r
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ �'
.(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt E]Yes ❑No How Determined
PARKS AND RECREATION FEE,
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑ Yes ❑ No How Determined
LIBRARY FEE
z.;
Land Account Land Credit Land Total
X.
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount �—
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
t. PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner.on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Single _Family Dwelling::
Plan-Review Comments . .
1. F.F:E. shall be:a:minimum-of 8"_above.the road elevation and an engineered.site.plan. .
I. Lotsshall be graded.to.comply with R401.3 of the F.B.C.
3. ;Compaction.test required if 24" or more:of ,fill dirt is brought in'at any one place.
4:. :Tie in survey required before'pounng concrete.'
5. Driveways require a R.O.W, use permit: All 4:sides of driveway thru the-sidewalk shall have.
expansion material:. :. .
6. All setbacks.shall be met...
7.: ;All property markers shall be-uncovered and marked at time of first.inspection:
8:- :All A.D.A. requirements.shall be met.: .
9. No:electric,plumbing,-mechanical; or framing shall be covered without an inspection and
approval first. .
10. A11 Garages shall;comply:.with:section R302.6 of the:F.B:C:;(Fire Separation).
11:Appliances.shall'not:be installed in:a location'where subject to mechanical damage unless.
1?rotected.bY1?p
a roved barriers. M303..4 o£the F.B.0
.. . . .-
12. Water heaters shall comply with section:P607.3 of the.F:B.C:
13. Foundation supports for-A/C-units.shall be raised at least 3" above finished grade. M1308.1.
14. Return air in All bedrooms.F.B.C. 1MI1620.4._ .
15: Smoke detectors are to b-e installed:in accordance with:R313:1 of the:F.B.C.
16: All glazing requirements are to be in accordance with R308.4_'of the F.B.C.-.
17.All means,of egress are o.be in:accordance with R311.of the F.B.C.
18.;`.`Green gypsum board shall-not be used as a backer.in showers or tubs. R702.442 F.B.C.
19. Combination-type A.FCI breakers are.required,at all.locations requiring.an AFCLtype breaker:
20. Carbon monoxide.alarms"Will be required in new construction that uses fossil-burning heating
:or appliances or an attached garage. ;They shall be,installed in accordance with.the F.B.0
21. All plumbing, mechanical and.electrical shall:be separate from unit to.unit- This includes all
undergroundplumbingand electric:
22. All 2016.N.E C. Codes will be enforced.. • .
23: Tamper- Resistant Receptacles in accordance with 406:11- of the 2016 N.E:C
24.Ah accordance:.with the Land:Development Code,lots shall be-sodded before final at least10
feet around:the structure. .. : _
25. Blower door:test and blown in insulation card shall be provided before C:.O.
26 A copy ofthe energy cacls.shall be with permit.at all times.
27 Cony of final insulation report shall be:provided with:yerniit�before TnaL
F.F:E.-Finished Floor Elevation
F:B.C=Florida Building:Code 6 h Edition
R.O.W.-Right of Way
A-D.A.-Americans with Disabilities'Act , : N.E.C.-National Electric Code(2011)
CM OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 37912 PRAIRIE ROSE LP LT 2 Owner: BUTTERFIELD MOBILE HOME SVC INC
ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN
Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542
Parcel: 15-26-21-0210-00000-0020 Work Type: 105-NEW CONST/MULTI 5+ UNIT
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 20112
Date: Q
� -31 06/2019
ISSUED BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO-ISSUANCE
^� . PASCO COUNTY
PAS
DEVELOPMENT SERVICES
C 8731 Citizens Drive Date: 12/19/2018
` ;COUNTY FLOItIDA' New Port Richey, FL 34654
OPEN SPric s.GSae�,tiT I'>1'+c:Es:��� � 727-847-2411
NOT A PERMIT
Receipt#: 1817599
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 2.00 1412796 $3.38 $3.38 1817599 12/19/18 .
Waste Condo, Multi-Family MH
in Park, per Unit
1526210210000000030 AND:1526210210000000020.
TOTALS: $3.38 $3.38
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1817599 Check ,;,. ',; 20529 534 BCCCPI5W 12/19/2018 $3.38
Total Payments: $3.38
:•vor; Address Phone
BAILEY CONTRACTING ; PERMIT VS 20113,20112
" ZHLLS
20113=37910 PRAIRIE ROSE LP LT 3
- '12=37912-PRAIRIE ROSE L C`t
tr Comments-
, 1:
.:1526210210000000030, •`.'
° •'.. 1526210210000000020•,
whlle you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by
First Billing payment services.,
i5 'yi
i t ;
•^ 1.'t
W :
;;,Myfteports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1
CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20111
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20111 Issued: 8/15/2018 Address: 37906 PRAIRIE ROSE LP LT 5
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 188,012.85 Total Fees: 8,170.79 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,170.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0050
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC
Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN
ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT TOWN HOME 1,669 SQ FT
APPLICATION FEES
BUILDING FEE 1,079.69 ELECTRICAL FEE 221.63 PLUMBING FEE 147.75
MECHANICAL FEE 103.43 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 52.10 FIRE INSPECTION FEES 12.50
PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
I?
Inspections Require ,
FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
fw I
CONTRAC ORS IGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Bailey Contracting-37906 Prairie Rose Lp 1,669 sq ft
Column
SQ. FEET PRICE
MAIN OR LIVING: 1,669 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 188,012.85
FEE SHEET $ 985.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,079.70
ELECTRICAL: $ 221.63
PLUMBING: $ 147.75
MECHANICAL: $ 103.43
SUB-TOTAL $ 1,552.50
TOTAL $ 1,552.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES'
PLANS TOTAL: $ 52.10
INSPECTION TOTAL: $ 12.50
PERMIT TOTAL
TOTAL: $ 64.60
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,744.23
PARK IMPACT FEES $ 769.56
i
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $
T I F'S: $ 1,657.00
99%1
$ 1,640.43
1% $ 16.57
TOTAL: $ 8,170.79
Jacqueline Boges
From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Thursday,August 16, 2018 1:35 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 37906 Prairie Rose 1p bp#201 11
##- Please type your reply above this line -##
Your request (#233868) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhillsfl.zendesk.com/hclrequests/233868
..................... .................. ........... ............. ............. ....................................... ............... ...............
Jose Canez (City of Zephyrhills, Support
Aug 16, 10:35 AM MST
I have created account#0000925820-0031 18639 1 have created JIRA to get property mapped.
once property is mapped i will create meter install order.
Best Regards,
Jose C. I FATHOM Support
.............. ...............1.1-...........-.11.................-.................................-................................. ............. ...........................-............................................... ................................................ .............................................
Jacqueline Boges
Aug 15, 1 :25 PM MST
37906 Prairie Rose 1p bp#201 11 water, sewer, water meter
This email is a service from City of Zephyrhills Support
Jacqueline Boges
Fnmro: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday,August 15 20184:26rw
To: Jacque|meuogoa
Subject: [Request received] 37gO0 Prairie Rose|pbn#2O111
## Please type your reply above this line -##
Hello Jacqueline 8oges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
...................--_--'__................_-___' .........._ ............-__...................--_-.........................- ...........--............ -.............'-_............................'__-.............
----_
°a-�
r�ueline Bog~~
- ' ^ Aug lS, 7 :25 PM MST
37906 Prairie Rose |pbc#20lllwater, sewer, water meter
- -
This email ise service from City ofZephyrhiUs Support .
1
Bailey Contracting 37906 Prairie Rose Lp. 1,669 sq ft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 1,669 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 188,012.85
FEE SHEET $ 985.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,084.70
ELECTRICAL: $ 221.63
PLUMBING: $ 147.75
MECHANICAL: $ 103.43
SUB-TOTAL $ 1,557.50
Public Fee 1%
TOTAL $ 1,557.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER:1 $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,684.63 .
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: $ 1,657.00 55 and over
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,111.19
15-26-21-0210-00000-0050 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, August 11, 2018
Parcel ID 15-26-21-0210-00000-0050 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
BUTTERFIELD MOBILE HOME Ag Land $0
SERVICE INC Land $4,290
38930 BUTTERFIELD LN Building $0
ZEPHYRHILLS FL 33542-1677 Extra Features $0
Physical Address
37906 PRAIRIE ROSE LOOP
ZEPHYRHILLS, FL 33542 Just Value $4,290
Assessed (Non-School Amendment 1) $4,290
Legal Description (First 4 Lines)
See Plat for this Taxable Value $4,290
Subdivision
WALNUT GROVE TOWNHOUSES
PB 69 PG 054
LOT 5
OR 6544 PG 1916
Jurisdiction
City of Zephyrhills
_ Land Detail (Card: 001 of 001)
Line _ Use Description_iZoning U in is �T p Price 'Condit not ValueY�_
1 r j 0100 SFR MPUD 2,750.00 �� SF ; $1.56� 1:00 $4,290
Additional Land Information
-- — - j^FEMA---��_---- i — -
Acres 0.06 Tax Area 30ZH I X Residential Code WGTHLPI
f t Code
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line (Description Year �JUnits _ lValue
No Extra Features
Sales History
Previous Owner: N/A
Month/Year ,Book/Page _ Type 'DOR Code Condition Amount
08/2005 E 6544 / 1916 _~ Warranty Deed I Vacant $600,000
11/1981 _1157 / 1702 _Vacant_ $130,000
01/1973 ( 0707/ 0675 j Vacant $0 _
http://search.pascopa.com/parcel.aspx?parcel=2126150210000000050 8/13/2018
PASCO COUNTY, FLORIDA
Permit No. .2—0
Date Permitted —
Builder Name/Owner Name � ► L LC Control#•
County Parcel No. SubDiv: t;(xc� 'ilt�bl^G
Address/Location 3 ( l C)b o r LT '5
Classification/Type a of Use 6(,(A 07v2
YP
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
w. Exempt ❑'Yes ❑ No How Determined
Ktl
. . Impact Fee Amount $ 7 Zone No. TAZ:
?z; SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt Yes ❑ No How Determined
PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No. How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By r Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing
the building permit owneron notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 37906 PRAIRIE ROSE LP LT 5 Owner: BUTTERFIELD MOBILE HOME SVC INC
ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN
Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677
Parcel: 15-26-21-0210-00000-0050 Work Type: 105-NEW CONST/MULTI 5+ UNIT
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 20111
Date: 3/06/2019
O'de.
6v-
ISSUE"Y: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
PASCO COUNTY
` DEVELOPMENT SERVICES
�.
PRSC �-
8731 Citizens Drive Date: 12/19/2618
OIJNTY FLORIDA New Port Richey, FL 34654
OPEN Sp.,km.T im-t-,r Pixms.'. : 727-847-2411
�+c�r !\B OT A 1 i **
- ` Receipt#: 1817593
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 2.00 1412789 $3.38 $3.38 1817593 12/19/18
Waste Condo,Multi-Family MH
in Park,per Unit
1526210210000000050 AND`1626210210000000040.
TOTALS: $3.38 $3.38
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
`la 1817593. Check 20529 534 BCCCP15W 12/19/2018 $3.38
Total Payments: $3.38
Pa or, Address Phone
:`.`.:BAILEYCONTRACTING'' : PERMIT WS 20110,20111
ZHLLS -3-7
20110=
20111=37906 P IRIE ROSE LP
Comments:
1526210210000000040
1526210210000000050,:
While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by
.First Biliing payment services.:
„.�.,sir :_'t-' ' •
1
a•_ - ol
1 '
'��� -_ a fi.l� '�i �.' �. '�; III.,� •
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1
ing e ami y we ing
Plan Review Comments:
1: RRE. shall be a minimum of.8" above.the road elevation:and an engineered site plan.
2. -Lots shall be graded to,comply with R4013 of the F.B.C. .
3. -Compaction:test required.:if 24" or more of-fill dirt is.brought in:at any one place:
4: Tie in survey required before pouring concrete.
5. Driveways:require a R.O:W,use permit. All 4:sides'of driveway thru the sidewalk shall have.
expansion material:
6. All setbacks shall be inet:. .
7. 'All property markers shall be uncovered and'marked at time of first 'inspection:
8:. :All A.D.A. requirements.shall be met. .
...9. No:electric.plumbing,.mechanical, .or framing shall be covered without an:inspection and
approval first. . ..
10. All Garages shall comply:.with:section R302:6.of the F.B.C.,(Fire Separation).:
11::Appliances shall'not:be installed in.a location where subjectto.mechanical damage unless
protected'by approved:barriers-. M303.4 of the F.B:C-
12. Water heaters shall comply with section.P607.3 of the F.B.C:
13. Foundation supports:for A/C.units shall be raised at least 3'.' above finished grade, M 1308.1.
14. Return air in all,bedrooms.F.B.C. M.1620.41
15: Smoke detectors are to be installed.in' accordance:with:R3111 of-theT.B.C.
16: All glazing requirements are to be in accordance with R308.4 of the.F.B.C.
17. All means.of egress are to:be in:accordante with R311::of the F.B.C.
18. `.`Green gypsum board"shall not be used:as a backer.in:showers or tubs. R702.4.2_F.B.C.
19..Combination-type AFCI breakers are required at all.locations requiring an AFCLtype breaker: -
20. Carbon monoxide alarms will be required in.new:construction that uses fossil-burninggli'ting
:or appliances or an attached garage. They shall be.installed in accordance with.the F.B.C.
= 21. All plumbing,mechanical, and:electrical shall:be.separate from unit.to unit: This includes all .
underground:plumbing and electric:
22. All 2016:N.E.C. Codes will be enforced:.
.23. Tamper- Resistant Receptacles in accordance with 4Q6.1 I.of the 2016 N.E:C .
: .24. In accordance.with the Land.Development.Code, lots.shall be sodded before final at least 10
feet around the structure. -
25. Blower door:test and blown in insulation card shall be provided before C.O.
26 A come of the energy eacls.shall be with permit-at all dihi s.
27. Copy of final insutatioir report shall be:tirovided with:permit before:final
F.F.E.-Finished Floor Elevation .:.
F.B.0 Florida Building Code 6a'Edition.
R.O.W.-Right of Way
A.D.A.-Americans-with Disabilities Act N.E:C.-National-Electric Code-(2011)
1
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 37908 PRAIRIE ROSE LP LT 4 Owner: BUTTERFIELD MOBILE HOME SVC INC
ZEPHYRHILLS, FL. 38930 BUTTERFIELD N
Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677
Parcel: 15-26-21-0210-00000-0040 Work Type: 105-NEW CONST/MULTI 5+ UNIT
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 20110
Date: a 3/ 6/2019
e &� --- - iFl� 92���
ISSUED BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20110
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION._-.'__ - __� LOCATION INFORMATION:
Permit#:20110 Issued: 8/15/2018 Address: 37908 PRAIRIE ROSE LP LT 4
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 188,012.85 Total Fees: 8,170.79 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,170.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0040
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC
Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD N
ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677
Phone: (813)377-7395 , Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT TOWN HOME 1,669 SQ FT
APPLICATION FEES
BUILDING FEE 1,079.69 ELECTRICAL FEE 221.63 PLUMBING FEE 147.75
MECHANICAL FEE 103.43 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3%4,, 473.78 FIRE INSPECTION FEES 12.50 FIRE PLAN REVIEW FEES 52.10
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57
Inspections Required
F OTER 2ND ROUGH PLUMB Misc INSULATION E LING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney.
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS 9IGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Bailey Contracting-37908 Prairie Rose Lp-1,669 sq ft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 1,669 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 188,012.85
FEE SHEET $ 985.00
ADDRESS $ 30.00
DRIVEWAY1 $ 45.00
BUILDING: $ 1,079.70
ELECTRICAL: $ 221.63
PLUMBING: $ 147.75
MECHANICAL: $ 103.43
SUB-TOTAL $ 1,552.50
TOTAL $ 1,552.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 52.10
INSPECTION TOTAL: $ 12.50
PERMIT TOTAL
TOTAL: $ 64.60
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,744.23
PARK IMPACT FEES $ 769.56
' I
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $
T I F'S: $ 1,657.00
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,170.79
Jacqueline Boges
From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Thursday, August 16, 2018 1:27 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 37908 Prairie Rose Lp by#20110
##- Please type your reply above this line -##
Your request (#233863) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/233863
............................................... .............................................................................................................................................................................................................................................................................. ..................................................
Jose Canez (City of Zephyrhills Support )
` -- ' Aug 16, 1 0:27 AM MST
I have created account#0000925820-0031 1 8634 1 have created JIRA to get property mapped.
once property is mapped i will create meter install order.
Best Regards,
Jose C. I FATHOM Support
................................................................................................................................. .................................................................................................................................................................................................................................
i Jacqueline Boges
Aug 15, 1 :23 PM MST
37908 Prairie Rose Lip by#201 10 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, August 15, 2018 4:24 PM
To: Jacqueline Boges
Subject: [Request received] 37908 Prairie Rose Lp by#20110
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephvrhilisfl.zendesk.com/hc/requests/233863
..................................................................................................................................................................................................................................................................................................................................................................................
{ Jacqueline Boges
L - - Aug 15, 1 :23 PM MST
37908 Prairie Rose Lp by#201 10 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
i
Bailey Contracting 37908 Prairie Rose Lp. 1,669 sq ft
Column El
SQ. FEET PRICE
MAIN OR LIVING: 1,669 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $
VALUATION $ 188,012.85
FEE SHEET $ 985.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,084.70
ELECTRICAL: $ 221.63
PLUMBING: $ 147.75
MECHANICAL: $ 103.43
SUB-TOTAL $ 1,557.50
Public Fee 1%
TOTAL $ 1,557.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,684.63
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $
T I F'S: $ 1,657.00 55 and over
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,111.In9
15-26-21-0210-00000-0040 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, August 11, 2018
Parcel ID 15-26-21-0210-00000-0040 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
BUTTERFIELD MOBILE HOME Ag Land $0
SERVICE INC Land $4,290
38930 BUTTERFIELD LN Building $0
ZEPHYRHILLS FL 33542-1677 Extra Features $0
Physical Address
37908 PRAIRIE ROSE LOOP
ZEPHYRHILLS, FL 33542 Just Value $4,290
Assessed (Non-School Amendment 1) $4,290
Legal Description (First 4 Lines)
See Plat for this Taxable Value $4,290
Subdivision
WALNUT GROVE TOWNHOUSES
PB 69 PG 054
LOT 4
OR 6544 PG 1916
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
� Use escriptionZ ype— CLine g Un onditionValue
1 0100 SFR MPU 2,750.00 j SF $1.556 1.00 $4,290
Additional Land Information
Acres i FEMA
0.06 ITax Area 30ZH I Cod ^X Residential Code WGTHLPI
_ I
Building Information - Use 00 - Unimproved (Card: 00.1 of 001)
Unimproved Parcel 00 - Unimproved
_ _ Extra Features (Card: 001 of 001)
Line _ _ Description 'Year — _ Units_ jValueu —_
No Extra Features
Sales History
Previous Owner: N/A
Month/Year ok/Page —jType - DOR Code Condition Amount T
08/2005 �_ 6544 /_1916 _Warranty Deed Vacant $600 000
11/1981 1157 / 1702 Vacant $130,000
01/1973 � 0707/ 0675^—I~T-�--�---�__ -_Vacant 0
http://search.pascopa.com/parcel.aspx?parcel=2126150210000000040 8/13/2018
ASCO COUNTY, FLORIDA
Permit No. ' 2D-11D
Date Permitted
Builder Name/Owner Name 434,1eq Control#'
County Parcel No. �5 7�—b2ca—� D nY� SubDiv: .
zi
:..;,
Address/Location 3 790r1��ar� IVJ�2
Classification/Type of Use f U w�le-
f TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: /,
Exempt ❑Yes ❑ No How Determined
Impact Fee Amount $. i 65 7 Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes ❑No How Determined
PARKS AND RECREATION FEE-
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 76f 66
e:•. Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amou
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing
the building permit owner,on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Single.family.Dwelling
Plan Review Comments
1.' RRE. shall be a-minimum- of.8" above the road.elevation and an engineered.site plan. .
2. Lots shall be graded to.comply with R401.3 of the F.R.C. _
p. 3. ;Compaction est required.if 24 or more:of fill dirt is.brought in:di ariy one place:
4: Tie in survey required before pouring concrete.
5. Driveways:require-a'R.O.:W, use permit: All 4:sides of driveway thru the sidewalk shall have.
expansion matenal:.
6.. All setbacks.shall be met.:
7. All.property:markers shall be_uncov - d and marked at time of first.inspection: -
.8.. All A.D.A.requirements.shall be met.:-
9.. No:electric;plumbing,.mechanical, or framing shall be covered without an:inspection and
approval first.
10.All Garages shall-comply.with-section R302:6-of the F.B.C.-(Fire $6 aration).
11.Appliaaces'shall not:be installed in-a location where subject to.mechanical damage unless
P.rotected.by approved barrier s. M303.4 of.the RB.0 _
12. Water heaters shall comply'with sectiona607.3 of the F.B.C:
13. Foundation supports-for'A/C.units shall be raised at least 3" above finished-grade.. M1308.1
14. Return air in all.:bedrooms.F.B.C. Ml620.4..
- 15. Smoke detectors are to-be installed:in acc6rdance.with:R313:1 of theT.B.C.
16::All glazing requirements are.to be-in accordance with R308.4,of the F.B:C. .
17. All means of egress are'to be in:accordanbe with R3IYof the F.B.C.
18. `.`Green gypsumboard"-shall not be'-used:as.a backer.in':showers or tubs.'R702.4.2.F.B.C.
19. Combination-type AFCI breakers are required,at all locations requiring.an AFCLtype breaker.
20. Carbon monoxide alarins will.be required in new:construction-that uses fossil-burning heating' .
:or appliances or an attached garage:..They shall be.installed in accordance with,the F.B.C:
21. All plumbing,mechanical, and.electrical shall be separate from unit to:unit. This:includes all. .
underground plumbing and electric:
22. All 2016.N.E.C. Codes Will'be enforced.
23:_Tamper=Resistant Receptacles in accordance with 406:11 of the-2016 NEC
..24-Ah accordance.With the Land Development:Code;lots.shall be-sodded before final at least 10
feet around the structure. :.
25.Blower door test and blown in insulation card shall be providedbefore C.O.
26 A copy ofthe energy caclsshall be with pern:it.at all times=
27 Copy of final insulation report shall be:provided.with perMit before:rnab .
F.F.E.-Finished Floor Elevation
FB.C-Florida Building Code 6th Edition
R.O.W.-Right of Way.
A.D.A:-Americans With Disabilities Act N.E.C.-.National Electric Code (2011)
PASCO COUNTY
':,__ s F* DEVELOPMENT SERVICES
8731 Citizens Drive Date: 12/19/2018
' COUNTY: FLORIDA New Port Richey, FL 34654
727-847-2411
** NOT A PERMIT **
Receipt* 1817593
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
s,'I• ,
' :.`a Impact Fee Residential Solid .24503100-329010 2.00 1412789 $3.38 $3.38 1817593 12/19/18
Waste Condo,Multi-Family MH
' in Park, per Unit
1526210210000000060 AND,1526210210000000040.
' TOTALS: $3.38 $3.38
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amf Paid
1817593 . Check 20529 534 BCCCP15W 12/19/2018 $3.38
Total Payments: $3.38
Pavor •' Address Phone
BAILEY,CONTRACTING.'' 4' 'ti PERMIT#'S20 929
' L__tS
2t3410='A7Q08 PRAIR1F.AeG
=•'• 20111=37906 PRAIRIE ROSE LP
Comments:
1526210210000000040
1526210210000000050
•,'j •'`,While you will be paying your bill with Pasop,COunty Development services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by
First Billing payment services.
ly`r:, •
I;
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1
is g. e Faml y Dwe in
g _
n Plan Review Comore is
I. F.F.E. shall be a minimum_of 8 above the road.elevation and an engineered site,plan.
2. Lots..shall be graded.to.comply with R401.3 of the'F.B:.C:
.3. ;Compaction test required if 24 or more.of fill dirt is.brought_in:at any one place.
4: Tie in' survey required before pouring concrete.
5. Drive ways:require a R.O:W. use permit.: All 4:sides of driveway thru the sidewalk shall have
expansion material:.
6. All setbacks.shall,be met.:. .
7._ All property:markers shall be_uncovered and marked at time of first inspection:
.
I.
.8:. :All A.D.A:requirements shall be met. .
9.: .No electric;plumbirig,_mechanicaL.or framing shall be covered without an.inspection and
approval first.. .
10. All;Garages shall:complymith-section R302:6-of the:F.B.C::(Fire S:eparation).
-11.Appliances:shall not be installed in.a location where subjectto.mechanical damage:unless.
pfotected-by approved barriers. M303'.4 of the F.B.0
12. Water heaters shallcomply:with section P607.3 of the F.B.C:
13. Foundation supports for.A/C units shall'b'eraised at least 3"above finished grade, M1308.1.
14. Return air in all:bedrooms. F.B.C. M1620,4,
15. Smoke detectors are to be installed in accordanee.with R313:1 of the F.B.C.
16::A11 glazing requirements-are:.to b.e in accordance with R308.4.of the F.B.C. .
17. All means.of egress are to be in accordance with-R311`of the F.B.G.
18. "Green gypsum.board" shall-not be used as.a backer in:showers or-tubs. R702:4:2-F.B.C:
19.-Combination-typeAFCI breakers.are,required at all.locations requiring an AFCI,type breaker:
20: Carbon monoxide.alarms.will be required in.new:construction that uses fossil-burning heating
or appliances or an attached garage: They shall be,installed in accordance with the F.B.C.
.21. All plumbing,mechanical,-and electrical shall be separate from unit to.unit: This includes all.
un ergroun p urnbin acid electric:
22. All 2016:N.E:C: Codes Will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N:E:C
24. In accordance.With the Land:.Development.Code, lots shall be.sodded before final of least 10
feet "around the structure.
25. Blower door test and blown in insulation card shall be provided before C.-O.
26.A copy ofthe energy cacls.shall be with permit-at-all times
.27.. Copy of final insulation report shall be:provided with:perihut before:fnaL
F.F.E.-Finished Floor.Elevation
F.B.C-Florida Building Code 6 h Edition
R.O.W.-Right of Way
A.D.A:-Americans with Disabilities Act N.E.C.-.National Electric Code(2011)
CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20108'�
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION- LOCATION INFORMATION
Permit#:20108 Issued: 8/15/2018 Address: 37904 PRAIRIE ROSE LP LT 6
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 105-NEW CONST/MULTI 5+ UNIT Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 210,880.80 Total Fees: 8,335.79 Subdivision: WALNUT GROVE TOWNHOMES
Amount Paid: 8,335.79 Date Paid: 8/15/2018 Parcel Number: 15-26-21-0210-00000-0060
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD MOBILE HOME SVC INC
Addr: 4209 GALL BLVD Address: 38930 BUTTERFIELD LN
ZEPHYRHILLS, FL. 33542 ZEPHYRHILLS FL 33542-1677
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT TOWN HOME 1,872 SQ FT
APPLICATION FEES
BUILDING FEE 1,191.89 ELECTRICAL FEE 246.38 PLUMBING FEE 164.25
MECHANICAL FEE 114.98 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 FIRE PLAN REVIEW FEES 52.10 FIRE INSPECTION FEES 12.50
PARK FEES TOWNHOMES 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1%_ 16.57
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
S�
Inspections Required
FOOTER 2ND ROUGH PLUMB Misc I INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC, MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your.failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Jacqueline Boges
From: Jose Canez(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Thursday,August 16, 2018 1:20 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 37904 Prairie Rose Lp bp#20108
Please type your reply above this line -##
I
Your request (#233855) has been updated. REPLY TO THIS EMAIL or click the link below:
htti)s://zephyrhilisfl.zendesk.com/hc/"reciuests/233855
...........--............. ............. ............. ............................ .......... ................-................. ............ .............
Jose Canez (City of Zephyrhills Support )
Aug 16, 10:19 AM MST
I have created account#0000925820-00311 8624 1 have created JIRA to get property mapped.
once property is mapped i will create meter install order.
Best Regards,
Jose C. I FATHOM Support
..................I.............-.................I-............I...................... ....................................................- .. ..................... .............. ............ ..........— ......
Jacqueline Boges
Aug 15, 1 :19 PM MST
37904 prairie rose 1p bp#201 08 water, sewer, water meter
This email is a service from City of Zephyrhills Support
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday,August 15, 2018 4:20 PM
To: Jacqueline Boges
Subject: [Request received] 37904 Prairie Rose Lp by#20108
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/233855
....................................................................................................................................................................................................................................................................................................................................................................................
I .
Jacqueline Boges
- ' Aug 15, 1 :19 PM MST
37904 prairie rose Ip by#20108 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Bailey Contracting-37904 Prairie Rose Lp-1,872 sq ft
o umn Es
SQ. FEET PRICE
MAIN OR LIVING: 1,872 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 210,880.80
FEE SHEET $ 1,095.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,191.90
ELECTRICAL: $ 246.38
PLUMBING: $ 164.25
MECHANICAL: $ 114.98
SUB-TOTAL $ 1,717.50
TOTAL $ 1,717.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 4,73.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ 52.10
INSPECTION TOTAL: $ 12.50
PERMIT TOTAL
TOTAL: $ 64.60
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,909.23
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: $ 1,657.00
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,335.79
Bailey Contracting 37904 Prairie Rose Lp. 1,672 sq ft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 1,872 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 210,880.80
FEE SHEET $ 1,095.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,196.90
ELECTRICAL: $ 246.38
PLUMBING: $ 164.25
MECHANICAL: $ 114.98
SUB-TOTAL $ 1,722.50
Public Fee 1%
TOTAL $ 1,722.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,849.63
PARK IMPACT FEES $ 769.56
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
T I F'S: $ 1,657.00 55 and over
99% $ 1,640.43
1% $ 16.57
TOTAL: $ 8,276.19
15-26-21-0210-00000-0060 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, August 11, 2018
Parcel ID 15-26-21-0210-00000-0060 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
BUTTERFIELD MOBILE HOME Ag Land $0
SERVICE INC Land $4,373
38930 BUTTERFIELD LN Building $0
ZEPHYRHILLS FL 33542-1677 Extra Features $0
Physical Address
37904 PRAIRIE ROSE LOOP
ZEPHYRHILLS, FL 33542 Just Value $4,373
Assessed (Non-School Amendment 1) $4,373
Legal Description (First 4 Lines)
See Plat for this Taxable Value $4,373
Subdivision
WALNUT GROVE TOWNHOUSES
PB 69 PG 054
LOT 6
OR 6544 PG 1916
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use Description!Z_oning 1Units jType Orice Condition a_ue-
1 �_ 0100 SFR MPU 2 750.00 SF i $1.56—1.00 $4,290
2 0100 SFR MPUD j 1,650.00 SF $0.05 i 1.00 $83
_Additional Land Information
Acres 0.10 ]Tax Areal 30ZH I
FEMA X I Residential Code WGTHLPI
I Code I j
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_Extra Features (Card: 001 of 001)
Line J bescription Year Umts Value
_ _ _ _-.-- _-_._._1 �_—._..__
No Extra Features
Sales History
Previous Owner: N/A
Month/Year (Book/Page Type _ ,DOR Code Condition Amount
08/2005 6544 / 1916 �1 Warranty Deed Vacant $600,000 4
11/1981 1157 / 1702 ^� Vacant ! $130,000
01/1973 T 0707/ 0675 j. j�— — # Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126150210000000060 8/13/2018
Permit No. 26
Date Permitted
S L� ��ff��Control
y�e
~Builder Name/Owner Name � r l(Iy, �-
_
County Parcel No. ��J-26 2(—j}2 �t3—CX �t�O(o0 SubDiv: b7GC tS1�(?fC
Address/Location tt�'r
ClassificatlaM'ype of Use
-;. TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: P�Z`
..:
Exempt C]Yes ❑ No How Determined
Impact Fee Amount $. .057 0 Zane No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ _
(057) Mobile Home
r` (058) Other Residential
123) Collection Fee
Exempt [�] Yes Q No How Determined
PARKS AND RECREATION FEE,
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation
//Total
Zone TOTAL AMOUNT $ �rPIS�
Exempt [1 Yes n No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes No How Determined Total Amount`=j—/—
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
5
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY
i
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for some.
DATE RECEIVED BY
RECEIPT NO. DATE BY
PASCO COUNTY
pA 1 DEVELOPMENT SERVICES
8731 Citizens Drive Date: 12/19/2018
',:COUNTY' FLORIDA New Port Richey, FL 34654
E�PEN SP:1crs".Vi»nnti r Pt�lchs.,., "`: 727-847-2411
* T A PERMIT
Receipt#: 1817589
FEE DESCRIPTION .ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid_ 24503100-329010 2.00 1412783 $3.38 $3.38 1817589 12/19/18
Waste Condo,Multi-Family MH
in Park, per Unit.
1526210210000000010 NAD 0060.
TOTALS: $3.38 $3.38
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1817589 Check 20529 534 BCCCP15W 12/19/2018 $3.38
Total Payments: $3.38
Pa or Address Phone
;.BAILEY CONTRACTING PERMIT#'S 20108,20109
ZH
201004 RR/IR�E ROSE I P I T F
20109=37914 PARIRIE ROSE LP LT 1
Comments:
1526210210000000060
152621021000000010 d
While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by
•�:`" :"First Billing payment services.
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1
Sin le Famil IDwelhn
g : Y g
Pla
n Review.Comments -
1. RF.. shall be.a.minimum:of.8"above the road.elevation and an engineered site plan. .
2.. Lots shall be graded.to.comply with R401.3 of the F.B:.C:
3.: Compaction test required if 24" or more of fill dirt is brought in:at any one place:
4. Tie in survey required-before pouring concrete.
:..5. Driveways require a R:Q.:W:use permit:. All 4:sides of driveway thru the sidewalk sha..11 Have.
:expansion n mateal:.
6.: All setbacks shall be'met.:
7. :All.property markers shall be uncovered and marked at time of first.'inspection:
8: :All A.D.A.requirements shall be met.: .
9.. No:electric.plumbing, mechanical; or framing sha11 be:covered without an.inspection and
approval first. .
10. All.Garages shall comply_with section R3016,of.the F.B.C.::(Fire Separation).
11:Appliances:shall'not:be installed in a location where siibjectto mechanical damage unless.
:protected:by approved,barriers. M3014 of.the F.B.C.
i2. Water heaters shall,comply with sectionT607.3 of the F.B.C:
13. Fomdatiori supports:for.A/C units shall be raised at least 3 above finished grade.. M1309.1
14.Return air in.all.-bedrooms.F.B.C. Ml620.4._
15. Smoke detecfors are.to be iristalled:in' accordance.-With.R313:1-of-the-F.B.C.
16: All glazing requirements are to be in-accordance'with R308A of the F.B.-C.
17. All means.of egress are to:be in:accordance with R311 of the F.B.C.. ::
18. `.`Green gypsum.board shall-not be used as.a backer.iw R7024. :2.F.B.C.
19..Combination-type AFCl breakers_are.required at all locations requiring an AFCI,type breaker:
20. Carbon monoxide.alarms will be required in.new:construction that uses-fossil-burning heating
:. :or appliances or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shallbe separate from unit to.unit. This includes all. .
undergrourid plumbingand electric: -
22. All 2016.N.E.C. Codes:will.be enforced:.'
.23.Tamper=Resistant Receptacles in accordance with 40611 of the 2016 N.E:C
24. In accordance:With.the Land.Development Code;_lots shall be sodded before final at least 10
feet around'the structure. :
25. Blower door test and blown in insulation card shall be provided before C.O. -
26 A copy of.the enem cacls shall be with Permit at all times..
27. Cony of findl insulation report shall be provided with:Permit before.Tnal
F.F.E.-Finished Floor Elevation
F B.C- Florida Building Code 6fl'Edition
R.O.W.-Right of Way
A:D:A:=Americans with.DisabilitiesRct N.E.C.-.National Electric Code(2011)
CITY OF ZEPHYRHILLS
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 37904 PRAIRIE ROSE LP LT 6 Owner: BUTTERFIELD MOBILE HOME SVC INC
ZEPHYRHILLS, FL. 38930 BUTTERFIELD LN
Subdiv: WALNUT GROVE TOWNHOMES ZEPHYRHILLS FL 33542-1677
Parcel: 15-26-21-0210-00000-0060 Work Type: 105-NEW CONST/MULTI 5+ UNIT
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 20108
Date. 3/06/2019
C
ISSUED Y: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
I IIIIII IIIII lllll lllll llill 111111111111111111111111111111111
2018119856
Permit No. Parcel ID No
!S= 2(o- 21. OZ/d OOC 60 6600
NOTICE OF COMMENCEMENT
State of FlOr dA County of Aaj C 0
THE UNDERSIGNED hereby gtves mortice that improvement wffl be made to certain real property,and In accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencenw t :
1. Description of Property. Parcel identification No. /S-2!O-Z/-, Q VO •00 coo-cogo
Street Address3y9N137912, 379/0,337?08i379P, 7664•3794y_ ralire Pak L.oe)
2. General Description of Improvemerd�Q y/ :Cn S Tr U C- 0A �7 (0 UAl 1 a n h o M tv G q`f Jr-4;1,j'
FL 3354+2
3. Owner Information or, information t the Lessee cmdracted for the"improvement
6lr Yt 'Od hoo-lol fj In e-
3M 25 /�`iin`e.-/GQ 12.4 Daide q(-� F L
State
Interest in Property: OWA C/
Name of Fee simple Titleholder.
(If different from Owner Fisted above)
Address T . City state
4. Contractor o e'r 41
yZ 40 f T-c// QI Z A 4P—A' b FL
—�— p 2 State
CCwb woes Telephone No.: 6 13 -7a '
S. Surety:A( A
Naffie"
Address City State
Amount of Bond: $ Telephone No.:
6. Lender.IV
Name
Address City State
Landels Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Name
Address City Stale
Telephone Number of Designated Per=r.
6. In addition to himself;the owner designates of
to receive a copy of the lienols Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration date of Notice of Commencement(the e)#ration dale may not be before the completion of construction and final payment to the
contractor,but wW be one year from the date of recording unless a different date Is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
U my gpri� ry I declare that 1 have read the foregoinlef. g notice of commencement and that the fads stated therein are true to the best
STATE OF FLORIDA
COUNTY OF PASCO
Signature of OwrmlYr lessee,or Owners or L s Authorized
Rcpt:1974519 Rec: 10.00 OfrrcerroiraaodPartner/Manager
DS: 0.00 IT: 0.00
07/17./2018 J. R. , DPtY Clerk � signat ��ysT
The foregoing Instrument was admowlad before me this-,(_ y of 4 20 L by urn P4 Id t _
(type of .e.g.,offkw,trustee,attorney in fad)for
`J 0 MAT, namy 9f parlyonbehafrof 0
tWInstrument wasenecutel
Produced Identification❑ Notary Sig—
Ida LL,-,[!!-
r'-cation Produced Name(Print) ��i7X/- � .X-(a•>/,�r;'
UJI
A y
t� PAULA 6.0'NEIL,Ph.D.PASC0 CLERK & COMPTROLLEk
07/27/2018 02:21 m 1 of .1
F�,,. OR BK 975..1 PG 377r�4 .
J�JJJlJJJf11t11t11�� '.
dt
STATE OF FLORIDA, COUNTY OF PASCO
THIS FOREGOING IS A
COPY OF THE DOCUMENT
TRUE AND CORRECT
In(Fodli, ON I OR OF PUBLIC RECORD IN THIS OFFICE
WIT NKIVIYHAND
AND A OFFICIAL
SEA
L
LcTHtIS
DAY OF
188 PAUSM O'NEI C4RK&�MPTROLLE yR
DEPUTY CLERK
4
OF
o l5u"
I,l:fl P I Il P
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: JAG
Date Received:
Site: 371W, 37�-e-8`
Permit Type: 'Tam ��-
e
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
i
This 7comm?en;tsheps 1 be kept with the permit and/or plans.
Kalvin Swit;(er—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: R0718366 Unit 8-2 to 8-5 Builder Name: Butterfield
Street: 4408 Court St Permit Office: City of Zephyrhills
City,State,Zip: Zephyrhills,FL,33542 Permit Numbec"JI06 bi P f?
Owner: "Typical"-Interior-Units 8-2 thru 8-5 Jurisdiction: 611600
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(640.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 453.33 ft2
b.Frame-Wood,Adjacent R=13.0 186.67 ft2
3. Number of units,if multiple family I c.NIA R= ft2
4. Number of Bedrooms 2 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1267.0 sqft.) Insulation Area
a.Under Attic(Vented) R=38.0 1267.00 ft2
6. Conditioned floor area above grade(ft2) 1267 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(47.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:ah 6 175
a. U-Factor: Dbl,U=0.30 47,00 ft2
SHGC: SHGC=0.25
b. U-Factor: N/A ft2 12,Cooling systems kBtu/hr Efficiency
SHGC: a.Central Unit 23.6 SEER:14.50
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor. N/A ft2 a.Electric Strip Heat 17.1 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.957 ft.
Area Weighted Average SHGC: 0.250 14.Hot water systems
8. Floor Types (1267.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1267.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits CF,Pstat
Glass/Floor Area: 0.037 Total Proposed Modified Loads: 35.04 PASS
Total Baseline Loads: 35.25
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this = z 0
Code. calculation indicates compliance s 9
fz
Z
a mac„
& -
60-4 with the Florida Energy Code. J
PREPARED BY: Before construction is completed
DATE: 07-19-18.
this building will be inspected for
compliance with Section 553.908 k-
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFlr.IAI ;,
DATE: [DATE: - 9±/-L-)V
44
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3-2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
7/19/2018 10:40 AM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: R0718366 Unit 8-2 to 8-5 Bedrooms: 2 Address Type: Street Address
Building Type: User Conditioned Area: 1267 Lot#
Owner Name: 'Typical'-Interior-Units 8-2 t Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Butterfield Rotate Angle: 0 Street: 4408 Court St
Permit Office: City of Zephyrhills Cross Ventilation: No County: Pasco
Jurisdiction: 611600 Whole House Fan: No City,State,Zip: Zephyrhills,
Family Type: Single-family FL, 33542
New/Existing: New(From Plans)
Comment:
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI , 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire Unit 1267 10136
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Master Bedroom 186 1488 No 2 1 1 Yes Yes Yes
2 Mwic 34 272 No 0 1 Yes Yes Yes
3 Master Bath 93 744 No 0 1 Yes Yes Yes
4 Wit 23 184 No 0 1 Yes Yes Yes
5 Great Rm Dining 343 2744 No 0 1 Yes Yes Yes
6 Kitchen 180 1440 Yes 0 1 Yes Yes Yes
7 - Den 105 840 No 0 1 Yes Yes Yes
8 Bedroom2 139 1112 No 1 1 1 Yes Yes Yes
9 ah 11 88 No 0 1 Yes Yes Yes
10 Bath2 50 400 No 0 1 Yes Yes Yes
11 Utility 30 240 No 0 1 Yes Yes Yes
12 Entry 73 584 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Master Bedroom 30 ft 0 186 ftZ ---- 0 1 0
2 Slab-On-Grade Edge Insulatio Mwic 1 ft 0 34 ftz ---- 0 1 0
3 Slab-On-Grade Edge Insulatio Master Bath 1 ft 0 93 ftZ ---- 0 1 0
4 Slab-On-Grade Edge Insulatio Wit 1 ft 0 23 ftZ ---- 0 1 0
5 Slab-On-Grade Edge Insulatio Great Rm Dining 13 ft 0 343 ftz ---- 0 1 0
7/19/2018 10:40 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
6 Slab-On-Grade Edge Insulatio Kitchen 1 ft 0 180 ft2 0 1 0
7 Slab-On-Grade Edge Insulatio Den 1 ft 0 105 ft2 __-- 0 1 0
8 Slab-On-Grade Edge Insulatio Bedroom2 loft 0 139 ft2 ____ 0 1 0
9 Slab-On-Grade Edge Insulatio ah 1 ft 0 11 ft2 ---- 0 1 0
10SIab-On-Grade Edge Insulatio Bath2 1 ft 0 50 ft2 ____ 0 1 0
11SIab-On-Grade Edge Insulatio Utility 1 ft 0 30 ft2 ____ 0 1 0
12SIab-On-Grade Edge Insulatio Entry 3.7 ft 0 73 ft2 ---- 0 1 0
ROOF
Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg)
1 Gable or Shed Composition shingles 1335 ft2 210 ft2 Medium N 0.65 No 0.9 No 0 18.4
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1267 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Master Bedroom 38 Blown 186 ft2 0.1 Wood
2 Under Attic(Vented) Mwic 38 Blown 34 ft2 0.1 Wood
3 Under Attic(Vented) Master Bath 38 Blown 93 ft2 0.1 Wood
4 Under Attic(Vented) Mtlt 38 Blown 23 ft2 0.1 Wood
5 Under Attic(Vented) Great Rm Dining 38 Blown 343 ft2 0.1 Wood
6 Under Attic(Vented) Kitchen 38 Blown 180 ft2 0.1 Wood
7 Under Attic(Vented) Den 38 Blown 105 ft2 0.1 Wood
8 Under Attic(Vented) Bedroom2 38 Blown 139 ft2 0.1 Wood
9 Under Attic(Vented) ah 38 Blown 11 ft2 0.1 Wood
10 Under Attic(Vented) Bath2 38 Blown 50 ft2 0.1 Wood
11 Under Attic(Vented) Utility 38 Blown 30 ft2 0.1 Wood
12 Under Attic(Vented) Entry 38 Blown 73 ft2 0.1 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
nrnt To Wall Type1 N Exterior Concrete Block-Ext InsMbster Bedro 5 12 8 8 0 101.3 ft2 0 0 0.2 0
2 E Exterior Concrete Block-Ext Infthster Bedro 5 8 8 8 0 69.3 ft2 0 0 0.2 0
3 W Exterior Concrete Block-Ext InSdhster Bedro 5 8 8 8 0 69.3 ft2 0 0 0.2 0
4 N Exterior Concrete Block-Ext InGdeat Rm Din 5 13 0 8 0 104.0 ft2 0 0 0.2 0
7/19/2018 10:40 AM EnergyGauge®USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
5 S Exterior Concrete Block-Ext InsdBedroom2 5 10 0 8 0 80.0 ft2 0 0 0.2 0
6 S Exterior Concrete Block-Ext Insul Entry 5 3 8 8 0 29.3 ft2 0 0 0.2 0
7 S Garage Frame-Wood Entry 13 11 4 8 0 90.7 ft2 0 0.14 0.2 0
8 S Garage Frame-Wood Den 13 12 0 8 0 96.0 ft2 0 0.14 0.2 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N Insulated Great Rm Din None .35 3 6 8 20 ft2
2 S Insulated Entry None .35 3 6 8 20 ft2
3 S Insulated Entry None .35 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 TIM Low-E Double Yes 0.3 0.25 N 15.0 ft2 1 ft 0 in 1 ft2 in Drapes/blinds Exterior 5
2 N 4 TIM Low-E Double Yes 0.3 0.25 N 12.0 ft2 8 ft 8 in 1 ft 2 in Drapes/blinds Exterior 5
3 S 5 TIM Low-E Double Yes 0.3 0.25 N 20.0 ft2 1 ft 0 in 1 ft 2 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 240 ft2 240 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000305 1013.6 55.65 104.65 .1117 6
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Strip Heat/ None COP:1 17.06 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:14.523.6 kBtu/hr 708 cfm 0.75 1 sys#1
7/19/2018 10:40 AM EnergyGaugeg)USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.97 40 gal 50 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
�/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 175 ft2 Attic 75 ft2 Default Leakage ah (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r Ma rl
Jun Jul rl
Au rl
Se Oct Nov Dec
Heatin f X�Jan f X�Feb Mar APr f May Jun Jul AuSep Oct Xj Nov HDec
Ventin [ Jan [ Feb X Mar A r [ Ma Jun Jul Aug Se [X Oct [X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Master Bedroom
Default(8 Ibs/sq.ft. ft2 ft 0.3 Mtlt
Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bath
Default(8 lbs/sq.ft. ft2 ft 0.3 Mwic
Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom3
Default(8 Ibs/sq.ft. ft2 ft 0.3 ah
Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom2
Default(8 Ibs/sq.ft. ft2 ft 0.3 Entry
Default(8 lbs/sq.ft. ft2 ft 0.3 Hall
Default(8 Ibs/s .ff. ft2 ft 0.3 Great Rm Dining
7/19/2018 10:40 AM EnergyGaugeO USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX*• 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b)Return ducts R 6.0
c)AHU location ah
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 2 13. Cooling system: Capacity 23.6
a)Split system SEER 14.5
5. Is this a worst case?(yes/no) 5. No b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1267 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a)U-factor:(weighted average) 7a. 0.300
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.250 14. Heating system: Capacity 17.1
c)Area 7c. 47.0 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8. Skylights c) Electric resistance COP 1.0
a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised(R-value) 9b. 15.Water heating system
c)Concrete, raised(R-value) 9c. a)Electric resistance EF 0.97
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 5.0 f)Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 13.0
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11. Ceiling type and insulation level a)Ceiling fans Yes
a)Under attic 11a. 38.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d)Multizone cooling credit
d)Radiant barrier installed 11d. No e)Multizone heating credit
f)Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: 4408 Court St City/FL Zip: Zephyrhills, FL 33542
7/19/2018 10:41:49 AM EnergyGauge®USA 6.0.02(Rev. 1)-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Manual S Compliance Report Job: R0718366
wrightsoft9 Date: 07-19-18
Entire Unit By: TMN
Bahr's Propane Gas &AC Inc
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
Project • •
For: "Typical'- Units 8-2 thru 8-5
4408 Court St, Zephyrhills, FL 33542
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 16608 Btuh Entering coil DB: 81.5°F
Outdoor design WB: 77.2°F Latent gain: 4003 Btuh Entering coil WB: 65.1°F
Indoor design DB: 75.0°F Total gain: 20610 Btuh
Indoor RH: 50% Estimated airflow: 787 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split AC
Manufacturer: Goodman or Eqv. Model: GSX140241L+ASPT33C14A
Actual airflow: 787 cfm
Sensible capacity: 17700 Btuh 107% of load
Latent capacity: 5900 Btuh 147% of load
Total capacity: 23600 Btuh 115% of load SHR: 75%
Heating Equipment
Design Conditions
Outdoor design DB: 42.9°F Heat loss: 10518 Btuh Entering coil DB: 67.5°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 261 cfm
Output capacity: 5.0 kW 162% of load Temp. rise: 59 OF
Meets all requirements of ACCA Manual S.
wrightsotV, 2018-Jul-19 10:37:22
^t .,.,..-, .�».-.,* , Right-Suite®Universal 2018 18.0.19 RSU07440 Page 1
AC+K ...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: 5
Project Summary Job: R0718366
wrig 1tsQf Date: 07-19-18
Entire Unit By: TMN
Bahes Propane Gas &AC Inc
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
Project ! •
For: "Typical"- Units 8-2 thru 8-5
4408 Court St, Zephyrhills, FL 33542
Notes: Load Calculation was obtained from an on-site inspection.
Design Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 7755 Btuh Structure 8625 Btuh
Ducts 2763 Btuh Ducts 4911 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none (none)
Humidification 0 Btuh Blower 3072 Btuh
Piping 0 Btuh
Equipment load 10518 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 16608 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2773 Btuh
Ducts 1230 Btuh
Central vent(0 cfm) 0 Btuh
Heating Coolingg (none)
Area(ftz) 1267 1267 Equipment latent load 4003 Btuh
Volume(W) 10135 10135
Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 20610 Btuh
Equiv.AVF(cfm) 76 39 Req. total capacity at 0.75 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Make Goodman or Eqv.
Trade Elec. Heat Trade Split AC
Model Cond GSX140241 L
AHRI ref Coil ASPT33C14A
AHRI ref 8655537
Efficiency 100 EFF Efficiency 12.0 EER, 14.5 SEER
Heating input 5.0 kW Sensible cooling 17700 Btuh
Heating output 17061 Btuh Latent cooling 5900 Btuh
Temperature rise 59 OF Total cooling 23600 Btuh
Actual air flow 261 cfm Actual air flow 787 cfm
Air flow factor 0.025 cfm/Btuh Air flow factor 0.058 cfm/Btuh
Static pressure 0 in H2O Static pressure 0.50 in H2O
Space thermostat Load sensible heat ratio 0.81
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-pp- wrlo!n Im- 2018-Jul-19 10:37:22
�- •-w-• Right-Suite®Universal 2018 18.0.19 RSU07440 Page 1
...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
-P�t-wrightsof- Right-JO Worksheet Job: R0718366
Entire Unit Date: 07-19-18
Bahr's Propane Gas &AC Inc By: TMN
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Entire Unit Master Bedroom
2 Exposed wall 56.7 ft 30.0 ft
3 Room height 8.0 ft d 8.0 ft heat/cool
4 Room dimensions 12.7 x 14.7 ft
5 Room area 1266.9 ft' 185.8 ft2
Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load
number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-5ocs 0.126 n 3.39 2.47 ' 205 1M 536 391 lot 66 292 213
4AS-2ob 0.300 n 8.13 8.01 12 0 98 96 0 0 0 0
4A5-2ob 0.300 n 8.13 8.01 15 0 122 120 15 0 122 120
11N0 0.350 _n_ -- -9.48 ,.10.83 ,-.20 20 191 .--,-- -",218 -- 0 0 _ -- 0 - 0
11 W 13A-5ocs_ 0.125 a 3.39 _ 2.47 69 69 _ 235 171 69 69 _ _ 235 _ _ 171
13A-5ocs 0.125 s 3.39 2.47 109 69 235 171 0 0 0 0
4A5-2ob 0,300 s 8.13 8.18 20 17 163 164 .0 0 0 0
11NO 0.350 s 9.48 _ 10.83 20 20_ 191 218 -0 0_ 0 0
W 13A-5ocs 0.125 w 3.39 2.47 - 69 69 235 171 69 69 235 171
PII - 12C-0sw 0.091 - 2.47 1.46 -. _203 185 456 270 0 0 0 0
r....D _11N0 0.350 ..n- .---_-.9.48 -- _10.83---.- _ -18___, . 18 169�---___194 -. _ --0 _-_--_ 0 _ 0_-._.... 0
P 12C-0sw _ 9.991.0 2.47 1.46 99 99 243 144 0 0 0 0
- - -. - _
C . _ 16B-30ad„ " _. "-_ "-__._0.032 .. _ ___.0.87_,. 1.74 __._1267 :_ :1267 ."_1099___ 2207, 186 "-"_- -186 _161 . 324
F 22A-tpl .,.. 0,989 _.26.80 . ._0.00__ __1267.._ -_57 1,519. Q .._._ .186 __-._30 __ 80.4 0
6 c)AED excursion 0 -4
Envelope loss/gain 5490 4534 1849 996
12 a) Infiltration 2265 701 1199 371
b) Room ventilation 0 0 0 0
13 1ntemal gains: Occupants @ 230 3 690 2 460
Appliances/other 2700 0
Subtotal Qines 6 to 13) 7755 8625 3048 1827
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 7755 8625 3048 1827
15 Duct loads W%l 57%1 2763 4911 36% 57% 1086 1040
Total room load 10518 135361 4135 2867
Air required(cfm) 261 787 103 167
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
w1rao lmim- 2018-Jul-19 10:37:22
AWk Right-Suite®Universal 2018 18.0.19 RSU07440 Page 1
...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
-I' -wrightsoft Right-M Worksheet Job: R0718366
Entire Unit By:
07-19-18
By: TMN
Bahr's Propane Gas&AC Inc .
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Mwic Master Bath
2 Exposed wall O ft O ft
3 Room height 8.0 ft heat/cool 8.0 ft heaticool
4 Room dimensions 1.0 x 33.7 ft 1.0 x 92.6 ft
5 Room area 33.7 ftz 92.6 ft2
Ty Construction U-value Or HTM Area (ftj Load Area (ft5 Load
number (Btuh/ftl°F) (Btuh/ft) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-5o6s_ - -0.125 n 3.39' 2.47 0 0 0- 0 0 0 0 0
4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
11N0 0.350 __n _9.48 --10.83 .0 .0 0 --0 -,-- -- 0 _ _0 0_ _.- 0
11 w 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0
13A-5ocs 0.125 s 3,39 2.47 0 0 0.._ - 0 0 0 0 0
4AS-2ob 0.300 s 8.13 8.18 0 0 0 0 0 0 0 0
11NO 0.350 s` 9.48 10.83 0 0 0 0 0 0 0 0
w__ ,13A-5ocs -- - -0.125 w 3.39 2.47_ -- -
P 12C-Osw 0.091 2.47 1.46 0 0 0 0 0 0 0 0
D,-11N0 _._ .. .. _. _-.- -_--- 0.350 ...n._ _ .__9.48 _.10.83-. '_ _--0 - _ .-- - 0 ... ._-0--=--- .0..-._.-. -0- _O_---_-- 0 _--__ 0
P 12C-Osw 0.091 2.47 1.46 C_ 0 0 0 0 0 _ 0 0 0 16B�Oad. _ ---0.032 -. _ __0.87..:_--_1.79 _-___ 34 ._34... 29 - 59 .. 93 93- 80_ - -161
22A-tpl- - --- 0.969 -26.80 ---0.00- - 34 -0 - __0- -0 .._. 93 --0 . . 0 _ .- . 0-
6 c)AED excursion 0 0
Envelope loss/gain 29 59 80 161
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 29 59 80 161
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 29 59 80 161
15 Duct loads 36% 57% 10 33 36% 57% 29 92
Total room load 40 92 j j 109 j 253'
Air required(cfm) 1 5 3 15
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-r w wrigEttsoft- 2018-Jul-19 10:37:22
Right-Suite@ Universal 2018 18.0.19 RSU07440 Page 2
...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJB Building Front faces: S
+wrightsoft- Right-JO Worksheet Job: R0718366
Entire Unit Date: 07-19-18
Bahr's Propane Gas&AC Inc By: TMN
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Wit Great Rm Dining
2 Exposed wall 0 ft 13.0 ft
3 Room height 8.0 ft heaticool 8.0 ft heat/cool
4 Room dimensions 3.7 x 6.3 ft 1.0 x 344.2 ft
5 Room area 23.2 ft2 344.2 ft2
Ty Construction U-value Or HTM Area (W) Load Area (ftl Load
number (Btuh/ft;°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat I Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Val 13A5ocs 0.125 - n -3.39 � 2.47 0 0 0 0 rv104 72 244 178
4A52ob 0.300 n 8.13 8.01 0 0 0 0 12 0 98 96
4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
11N0. - - - 0.350 n_ _.. _9.48 ._..... 10.83 --- --0 _ - -- 0 - 0- ._ -0 :_. _...20 _ .,__20.. _ 191. 218
11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0
V�J 13A-5ocs "0.1215 s 3.39 2.47 0 0 0 0 0 0 -0 0
4A5-2ob 0.300 s 8.13 8.18 0 0 0 0 0 0 0 0
11NO 0.350 s_ 9.48 _1083- .0 0 -, _0 -- -0 0 .. - 0, -0 - 0
W, .1 3A-5ocs, 0.125 w-_ _ 3.39. 2.4-7 __ 0 0 _ _ 6. _ 0 0 6 0 0
PI - 12C-Osw 0.091 - 2.47 1.46 0 0 0 0 0 0 0 0
L-DL-D 11NO 0.350 .n _9.48 .._10.83 0 . . _._. 0 -,0__, ._ _0 .. _ . 0 .._ ... -0 0_. ,. 0
P„ 12C-Osw - 0.091 _-__, _ _2.47 1.46 0
C,_ __ 16B-30ad,. _ ..__ 0.032._. ._____0.67 1.74 ._._ .23 - _ _ 23- .-_.-,.20 _._40._-_. 344__.._ 344._:..._..296__ .600
F _ 22A-01 0.989_- 26.80 _0.00 ,----23___ 0 - __.._0.
- - _ ___0 .. .344 _13._.. . 348 _ -- ._ 0
6 c)AED excursion 0 -4
Envelope loss/gain 20 40 1179 1097
12 a) Infiltration 0 0 520 161
b) Room ventilation 0 0 0 0
13 Internal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 900
Subtotal pins 6 to 13) 20 40 1698 2148
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 20 40 1698 2148
15 Duct loads 36% 57% 7 23 360/a 57% 605 1223
Total room load 27 63 2303 3370
Air required(cfm) 1 4 57 196
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- wrigtatsoTt- 2018-Jul-1910:37:22
A&K Right-Suite®Universal 2018 18.0.19 RSU07440 Page 3
...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
-r�t-wrightsofta Right-M Worksheet Job: R0718366
Entire Unit Date: 07-19-18
Bahr's Propane Gas&AC Inc By: TMN
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Kitchen Den
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 1.0 x 179.9 ft 1.0 x 104.7 ft
5 Room area 179.9 ft' 104.7 ft2
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft2°F) (Btuh/ft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-5ocs 0.125 n 3.39 2.47 0 0 0 0 0 0 0 0
1q�J--G 4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
I-G 4A5.2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
11NO 0.350._n- _ __9.48 - -10.83 .__ 0 0 __0 _ 0--
0
11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0
13A-5ocs . 0.125 s 3.39 - 2.47 0 0 0 0 0 0 0 0
4A5-2ob 0.300 s. 8.13 8.18 0 0 0 0 0 0 0 0
11N0. 0.350-_.s .. 9. -._._10.83 -0 0 _.. ... .0_- - 0 -0 0 0 0
W 13A-5ocs ._ ._. _. _ _9.125 _w 3.39 2.47.- -0 _ _0 -. . 0 .. 0_. 0 _ _ 0 0 0
P 12C-0sw 0.091 - 2.47 1.46 0 0 0 0 109 109 270 160
11N0, 0.350 . n- ____9.48 ._. 10.83. -,-- -0.. 0 -0 _0 _ - _. _0 _0. 0_=. 0
P 12G-Osw_ _ 0.091 .,, 2.47 __ 1.46 _-_-.,- _ 0 -_ 0
0_ 0 0 0 0 0
Q 16B-30ad-.,_; .- , __ __- 0.032_- ,_ _ _-0.87 __-_ 1.74 _ .-180 .180 156-_._ _313 105 __ 105__.. _ 91- _ __- _182
__.0.989 .-_-- _26.800.00 _-_1.80
6 c)AED excursion 4 -1
Envelope loss/gain 156 309 360 341
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 1800 0
Subtotal Vines 6 to 13) 156 2109 360 341
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 156 2109 360 341
15 Duct loads 36% 579/6 56 1201 W% 57% 128 194
Total room load 212 3310 489 536
Air required(cfm) 5 192 12 31
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- wriigE�tsoft^ 2018-Jul-1910:37:22
Right-Suite@ Universal 2018 18.0.19 RSU07440 Page 4
...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
- -wrightsoft Right-.10 Worksheet Job: R0718366
Entire Unit Date: 07-19-18
Bahr's Propane Gas&AC Inc By: TMN
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Bedroom2 ah
2 Exposed wall 10.0 ft 0 ft
3 Room height 8.0 ft heaticool 8.0 ft heat/cool
4 Room dimensions 1.0 x 138.9 ft 3.3 x 3.3 ft
5 Room area 138.9 ft2 11.1 ftz
Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load
number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 13A-5ocs 0.126 n 3.39 -2.47 0 0 0 6 0 0 0 0
4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
'h
4A5.2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
11N0 - --, _ _ - - ----.0.350 .-n-_-__.9.48 10.83 -. _ -- -- A-- 0 0 ---0,-__-- 0. ..._ 0 0 - -0
11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0
1rN 13A-5ocs 0.125 s 3.39 Z47 80 60 203 148 0 - 0 0 0
I{---GD 4A5-2ob 0.300 s 8.13 8.18 20 17 163 164 0 0 0 0
111N[01 __...- _ - _0.350 -s_ ' 9.48 _ _10.83 - - _. 0 0 0. _
W 13A-5ocs _ 0.125_ w 3.39 __ - 2.47
0 0 0 0 0 0 _.. 0. -_ 9
PI - 12C-0sw 0.091 - 2.47 1.46 0 0 0 0 0 0. 0 0
.11N0,.__ - _0.350 .n- _.9.48 10.83 _ ._. 0 - _ ._0-- _ 0._ --%0- _- _ 0_-_- .0 0 .:_. 0
P 12C-0sw _0.091 _2.47 1.46 99 _ 99,, 243 ._ 144 0. _
C _ 16B-30ad_- - - 1 0. 0
_ --... 0.032 -- - 0.87..__. 1.74 ,-_.-_.139 13.9, .. 120 -_ --,242 . _- _11 -- __._ .f _- 16 19.
F 22A-tPl_. 0.989 „26.80 - __0.00 tl_ ._.139 _ 10 268 -_--. _ 0 . . 11 0- 0
6 c)AED excursion 15 0
Envelope loss/gain 998 713 10 19
12 a) Infiltration 400 124 0 0
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 1 230 0 0
Appliances/other 0 0
Subtotal(lines 6 to 13) 1397 1066 10 19
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 1397 1066 10 19
15 Duct loads 36% 57% 498 607 36% 57% 3 11
Total room load 1895 1674 1 13 30
Air required(cfm) 47 97 101 2
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrGg[�tsoft^ 2018-Jul-19 10:37:22
Right-Suite®Universal 2018 18.0.19 RSU07440 Page 5
rove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
-P�t-wrightsoft, Right-J®Worksheet Job: R0718366
Entire Unit Date: 07-19-18
Bahr's Propane Gas&AC Inc By: TMN
4441 Allen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Bath2 Utility
2 Exposed wall 0 ft 0 ft
3 Room height 8.0 ft heat/cool 8.0 ft heat/cool
4 Room dimensions 10.0 x 5.0 ft 6.3 x 4-7 ft
5 Room area 50.0 ft' 29.6 ft2
Ty Construction U-value Or HTM Area (ft� Load Area (ft� Load
number (Btuh/ft'°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 Vh 13A-Socs 0.125 n 3.39 -2.47 0 0 0 0 0 0 0 0
4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
4A5-2ob 0.300 n 8.13 8.01 0 0 0 0 0 0 0 0
_ . __n_.. - --9.48 10.83 _ _ .0 . .11N0 0350-_ 0 0- - -0 0 - - - 0 0
0
11 W 13A-5ocs 0.125 a 3.39 _ 2.47 0 0 0 0 0 0 0 0
yJ 13A-5ocs 0.125 s 3.39 2.47 0 0 0 _._._ _ O _ _..- 0 - 0 - - 0 0
I�(p 4A5-2ob 0.300 s 8.13 8.18 0 0 0 0 0 . .0 0 0
11NO 0.350 s .- _ -9.48 _._10.83 _ 0_ _ 0_ -_ 0 _ 0_ _ 0
W 13A-5ocs 0.125 ,w_,--- 3.39 2.47 _ 0 0 0 0 0 0 0 0
P 12C-Osw 0.091 - 2.47 1.46 0 0 0 0 0 0 0 0
11NO _ _0.350 _.n. 9.48 10.83 _ .0 - _.0_ 0 -0- - __-0 _ -0, 0- . 0
P _- - 12C-Osw-. 0.091, _- 2.47. , -. 1.46.- .- -- 0__ _..._ . Q
C.. 16B-30ad -1.74 : _ 50 .... , 50 43 _87-
30 .--- ...30,-,_ -_-__26 51
F., - 224-tpl . 0.989 - _ .. _26.80 ., _ 0.00 50 0 _ 0
- _ 0 .. 30 - 0 -- -- 0 -- 0
6 c)AED excursion 0 0
Envelope loss/gain 43 87 26 51
12 a) Infiltration 0 0 0 0
b) Room ventilation 0 0 0 0
13 Intemal gains: Occupants @ 230 0 0 0 0
Appliances/other 0 0
Subtotal pines 6 to 13) 43 87 26 51
Less external load 0 0 0 0
Less transfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 43 87 26 51
15 Ductloads 36% 57% 15 50 369/6 57% 9 29
Total room load 59 136 35 81
Air required(cfm) 1 8 1 11 5
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
a -wrigE�tsott- 2018-Jul-19 10:37:22
-� ---�--• Right-Suite®Universal 2018 18.0.19 RSU07440 Page 6
...ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
- -vvrightsoft' Right-JO Worksheet Job: R0718366
Entire Unit Date: 07-19-18
.
Bahr's Propane Gas &AC Inc By: TMN
4441 Alen Rd,Zephyrhills,FL33541 Phone:813-782-5013
1 Room name Entry
2 Exposed wall 3.7 ft
3 Room height 8.0 ft heat/cool
4 Room dimensions 3.7 x 20.0 ft
5 Room area 73.3 ft2
Ty Construction U-value Or HTM Area (ft� Load Area Load
number (Btuh/ft?°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 b
13A5ocs 0.125 n 3.39 2.47 0 0 0 04A5-lob 0.300 n 8.13 8.01 0 0 0 0
4A5-lob 0.300 n 8.13 8.01 0 0 0 0
. 11NO-.-- -.._.__0.350 _n_ ..9.48 _ 10.83-- _ ., 0 -0 __0
11 W 13A-5ocs 0.125 a 3.39 2.47 0 0 0 0
V+J 13A-5ocs 0.125 s 3.39 2.47 ,29 9 31 23
4A5-2ob 0.300 s 8.13 8.18 0 0 0 0
11NO 0.350 -s _ 9.48 10.83_--_- 20. 20 191 __ 218
W 13A-5ocs 0.125, w. -__ 3.39 2.47- 0 6--_ 0 -
P 12C-Osw 0.091 - 2.47 1.46 93 75 186 110
.11N0 - 0.350 .n - __ _9.48 10.83. -.. -18 _ 16. 169_ - _ -194 -__-
P 12C-Osw - - 0.091.. -- _2.47 _..._ 1.46 ._. --0 ,. .. ._0
C. 16B-30ad 64- --B
- .0.032.-' - _0.87_....1.74 - -
F 22A-td - _ _- _-_0.969 _26.80 _,_0.00 _ 73_. .. . . 4 _ 98 -- 0
6 c)AED excursion -1
Envelope loss/gain 739 671
12 a) Infiltration 147 45
b) Room ventilation 0 0
13 Internal gains: Occupants @ 230 0 0
Appliances/other 0
Subtotal(lines 6 to 13) 886 716
Less external load 0 0
Less transfer 0 0
Redistribution 0 0
14 Subtotal 886 716
15 Duct loads 36% 57% 316 408
Total room load 1202 1124
Air required(cfm) 301 65
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-M wrigl%tsoTt 2018-Jul-1910:37:22
Right-Suite(E)Universal 2018 18.0.19 RSU07440 Page 7
ut Grove-6 Unit\R0718366 Unit 8-2 to 8-5.rup Calc=MJ8 Building Front faces: S
PASCO COUNTY
DEVELOPMENT SERVICES
8731 Citizens Drive Date: 12/19/2018
tflIJNTy.:.FLORIDA New Port Richey,FL 34654
okl(SPUMS.V1P.R U,rr PU48. 727-847-2411
NOT A PERMIT
Receipt#: 1817599
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 2.00 1412796 $3.38 $3.38 1817599 12/19/18
Waste Condo, Multi-Family MH;
in Park,per Unit
1526210210000000030 AND 1526210210000000020.
TOTALS: $3.38 $3.38
Receipt#:. Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1817599 Check 20529 534 BCCCP15W 12/19/2018 $3.38
Total Payments: $3.38
P_avL:.. Address Phone
BAILEY CONTRACTING PERMIT## 2&143 261 �4
L 20113=37910 PRAIRIE ROSE LPJ�
20112=37912 PRAIRIE ROSE LP LT 2
Comments:
1526210210000000030
1526210210000000020. ;
L y, While you.wlli be paying your bill with Pasco County Development Services,the full amount of the credit card or e•check fees,NOT shown above,Is collected by
P6st-8illing payment services,;i
'i.
MyReports/reports//PASCOPROD/PASC.O/ReceiptPOS V6.rpt 12/19/2018 Page 1 of 1
813-780-0020 City of Zephyrhills Permit Application Fax-813-7804°021
Building Department
Date Received , -, Z 5—/ Phone Contact for P iiting
Owners Name lJ� Y�� 1,(e Owner Phone Number 3 '
Owners Add csa. Owner Phone Number
S
Fee Simple Titlehoider Name �C^r`'r U'PS er Phone Number
Fee Simple Titleholder Address
�[ 3 JOB ADDRESS tr U b `�� U/�`-' �c l� �.� n- LOT#
LOT# f
SUB13MSION Jrtu —&YI-aa4 PARCEL ID# /e� �.� —.�_ Q v�d" 066 G2 S?C-9 Q.�C3
(06TAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR B ADD/ALT = SIGN = = DEMOLISH
INSTALL REPAIR
PROPOSED USE �SFR Q COMM Q OTHER
TYPE OF CONSTRUCTION L�d�/ BLOCK Q FRAME Q STEEL Q
DESCRIPTION OF WORK �CJu'a'`y V'#ti'r
BUILDING SIZE SQ FOOTAGE HEIGHT
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION
i
=ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C.
=r'LUMBING $
31z
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION • (00 '� '''
JcZ.CO
=GAS = ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N I FEE CURREn Y/N
Address License#
ELECTRICIAN COMPANY67
SIGNATURE REGISTERED / N FEE CURREn I Y/N
Address Q '- l License# qG 1DDt�f7� .
PLUMBER ( i �//�}/��y�� COMPANY I L S •I
SIGNATURE rJ c[���/"`�yy ``rr REGISTERED I YIN I FEE CURREn I Y!N
Address f g G'17r C 5 Licensee#
MECHANICAL / COMPANY fte
SIGNATURE REGISTERED I Y/ N FEE CURREn I Y/N
Address � J�� 1 eA) License# 641W V-y
OTHER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREN LILN
Address License#
ttttltllltllllllllltttllllttllllllltltllltttltlllttttllttlltllllttl
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stomnwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
PROPERTY SURVEY required for all NEW construction.
Directions:
Fill our application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
" Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if an public roadways..needi ROW
� .
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to restrictions"
Which may The_undersigned assumes_responsibility for_compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR n the owner has hired o contractor or
contractors mundertake work,they may be required to be licensed m accordance with state and local
ntractor is not licensed as required by law, both the and contractor may ue cited for a misdemeanorvmopuun
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
Cvvn
TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and
90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of
certifyfinal power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Horneowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement
CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the Information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
~ that.understand that the regulations..other government agencies may intended work,and that--
mv responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
Department o _n.'—' —_l Protection-Cypress Bay heads, Weiland Areas and Environmentally Sensitive
--
Lands'Water/Wastewater Treatment
' Southwest Florida vvate, Management Dost8vt-xe||o. cnneoe Bovhaaus. Weiland Areas, Altering
Watercourses.
' Army Corps o,Engineers-Seawalls,Docks,Navigable
' Department of Health & Ryhom\uoVve Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
' uo Environmental Protection Agency-Asbestos abatement.
' Federal Aviation
/understand that the following restrictions apply m the use mfill: .
' Use of fill|m not allowed m Flood Zone'Vr unless expressly pennmed.
' If the xU material is to be used in Flood Zone "A". it is understood that u drainage addressing u
^onmponoaUnovolume"Will be submitted at time nf permitting which is prepared by professional engineer
licensed uy the State ofFlorida.
' If the fill material ivuomo used in Flood Zone'Km connectionwith o permittedbuilding using stem wall
nonmmnUon.|certify that fill will be used only»o fill the area within the stem wall.
' /f fi|/ material is to be used in any area, | certify that use of such fill will not adversely
n of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air Conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued.shall become invalid
unless the wo,fk authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING To OWNER: YOUR FAILURE ro RECORD A NOTICE op COMMENCEMENT MAY RESULT|mYOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. |p YOU INTEND ro OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Subscribed and sworn o(or affffrned)before me Via Subscribed and sworn to(Tr affirmed)before me thl
by by
Who islare personally known to me or has/have produced Who is/are personally known to me or has/have produced
_ap identification. as identification.
Notary Public Notary Public
Commission No. Commission No
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped