Loading...
HomeMy WebLinkAbout18-20159 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20159 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20159 Issued: 8/30/2018 Address: 3229 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total Fees: 17,872.97 Subdivision: HIDDEN RIVER Amount Paid: 17,872.97 Date Paid: 8/31/2018 Parcel Number: 24-21-0100-00000-1240 CONTRACTOR INFORMATION, OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT APPLICATION FEES BUILDING FEE 1,482.60 ELE TRICAL FEE 310.50 PLUMBING FEE 207.00 MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 , � C-TA . 7 Ins ection uired FOOTER 2 D ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. N_O OCCUPANCY BEFORE C.O. J CON CTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES I �NTHS WITHOUT APPROVED INSPECTIO Q:a�LL e-�sR 6.�0 ION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Friday,August 31, 2018 3:40 PM To: Jacqueline Boges Subject: [Request received] 3229 Kresterbrooke Lane by#20159 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/237089 ...................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Aug 31 , 1 2:40 PM MST 3229 kresterbrooke lane by#201 59 water sewer This email is a service from City of Zephyrhills Support . 1 Lennar Homes-3229 Kresterbrooke Lane 2,376 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTALl $ 2,145.00 TOTAL $ 2,145.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,272.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,872.97 —^ 81 . City of Zephxrhii|8PGrDit Ap plication Fa»03-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 2891 x m x x�-oo//nx n u x n Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607____1 owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS rbrooke Lane __T_ muoom|m|om Hidden River PhasepxRosL|o# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW cowaTx| | ADD64LT [ � s|sw L | L � DEMOLISH INSTALL �—1 REPAIR PROPOSED USE Spn �-7 COMM �--1 OTHER oTnuon�m Tvpsopoom uLocx L_� rw^mE L--_) S/EEL DESCRIPTION opWORK Single Family Residence Pool/Screen Enclosure/Fence ' U/R SF BUILDING SIZE aQ FOOTAGE E�K__] xe|oxT 1 1 StOrYIBUILDING VALUATION OF TOTAL CONSTRUCTION pUJ�a|N� � ~ ~ MECHANICAL VALUATION OF MECHANICAL INSTALLATION =omS h���� SPECIALTY[—� e��ocr/ = OTHER FINISHED FLOOR ELEVATIONS 1 FLOOD ZONE AREA D ��YES O BUILDER /x-, o/omxTumE LY/ N�J pssounnsx Auo,w� F�W FL 33607 License sLsCnno|mm ' COMPANY I Edmonson Electric, Inc. SIGNATURE F 4Z REGISTERED L_Y/ N FEE uunnsx ��_] Address 11034 Skipper Road,Xmpa, FL 33613 Uoonue# PLUMBER — COMPANY 113ayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ NL] pseounesN Y/N_� Address uoonae# MscHxN|oxL COMPANY Bayonet Plumbing, Heating &AC, Inc m/om4TumE REGISTERED Y/_N_ rsEounnsN Y/N_] off Address Uoonoe# orVEm COMPANY SIGNATURE �o o y/ N rssoURnEN � Address 14211 Shoal Line Blvd, SSpring Hill, FL 346 Ummue# 57991 oxmxxowox � xxVmxxwuxnonnmnxxwoxuuxxunnnmnxmnnxmxxmmxxuxnumxxmnxnmxxw RESIDENTIAL Attach(2)Plot Plans;(2)sets vf Building Plans;(1)set of Energy Forms;R-O-WPonnit for new construction, Minimum ten(1U)working days after submittal date. Required onaKe.Construction Plans,0onnwmmr Plans vw Silt Fence installed, Sanitary Facilities&1uumpstor Site Work Permit for subdivisions/large projects coMMsncuu xuovx(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. **=peopERTY SURVEY required for all NEW construction. ' . Fill out application completely. Owner m Contractor sign back u*application,notarized If over$2500 a Notice of Commencement|arequired. (wo upgrades over$reuo) � Agm�����con�ado�mPmx�rof��omey�x0enwno�wu�ubuoomoone��n�o��d|a�o from o'mhohzingueme OVER THE COUNTER PERMITTING (copy o«contract required) nomnfsnshingles Gaxmm Service Upgrades A/C Fenmas(P(nV8unvey/Fvvtago) Driveways-Not over Counter|,nn public maoways..noodoROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain' as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a ,.compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. P - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,-1 certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools,_air- conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended-or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension: If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE QF COMMENCEMENT. FLORIDA JURAT,(F.S.117 3) OWNER OR AGENT aa6l_ CONTRACTOR l/r✓ Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this I a-Jun=10,by Ashlee Callahan 13-Jun-18 by Ashlee Callahan Who is/are personally known to me or hasihave^F^dU^^' Who is/are personally known to me or as identification. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped EdI�SJi>#,81�� p' I WW..1� h�4A►�81�t96i�141u' v� rAI fl*PP Row I'Cvrakhn 1P P 0 moll' i I IsIY��10 Baa�+I1nIN YaayFaloas,radeuliiwts +11 � _ 6md�k6NT;tgFala:441o194Jlt�i�l¢�pll I � -- - Lennar Homes-3229 Kresterbrooke Ln:2,376 sgft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: $ 88.00 OTHER: - $ - VALUATION $. 267,656.40 FEE SHEET $ 1,425.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,533.50 ELECTRICAL: $ 320.63 PLUMBING: $ 213.75 MECHANICAL: $ 149.63 SUB-TOTAL $ 2,217.50 Public Fee 1% TOTAL $ 2,217.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL. $ 6,344.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,945.47 Single Family_ Dwelling Plan Review Comments 1: F.F.E. shall be a minirnum:of 8- above.the road.elevation and an engineered.site plan. 2.- Lots shall be graded.to-comply with R401.3 of the F.B:C: .3.: Compaction:test required.if 24" or more of fill dirt"is brought in: any one place: 4 Tie in survey regquired before pouring concrete.' 5.1 Driveways require-a R.,O.:W. use permit.: All 4:sides of driveway thru the-sidewalk shall have. expansion material: 6- All setbacks shall.be 'met.: . 7. All property markers shall be uncovered and marked.at time of first 'inspection: 8: All A.D.A. requirements.shall be met.: . 9.. No:electric;plumbing,.mechanical;,or framing shall be covered without an inspection and approval first. . 10. All Garages shall-comply:with section R302.6:of the F.B.C.(Fire Separation)., 11:Appliances:shall not be installed in:-A-location where'subj ect to me'echanical damage unless. protected by approved barriers. M303.4 of.the F.B.C. 12. Water heaters shall comply,with sectionP607.3 of the F:B.C: 13. Foundation supports for AIC.units shall be raised at least 3"above finished grade. M1308.1. 14. Return air in all.bedrooms..F.B.C. .M_1620.4_: .-15: Smoke detectors are to be iristalled_in accordance.with R3111 of the.F.B.C. 16:All glazing requirements are.16 be-in accordance with R308.4 of the.F.B.C. 17. All means,of egress are to:be in:accordance with R311 of the F;B.C. :: 18. "Green gypsum:board shall not be used.as.a backer.irishowers ortubs.R702.4:2.F.B:C. 19. Combination-type AFCI breakers are required.at all locations requiring.an AFC1.type breaker: 20: Carbon monoxide alarms will.be required in.new:construction.that uses fossil-burningheating or appliances or an attached garage: They shall be,installed in accordance with the F,B.C:. 21. All plumbing, mechanical,.and electrical shall-be separate from unit to.unit: This includes all. underground plumbing and electric: 22. All 2016.N.E.C. Codes:will.be enforced-.. 23.Tamper=Resistarit Receptacles in accordance with 406.11 of the 2016 N.E:C .24: In accordance:.with the Land:.Development:Code'.lots shall be sodded before final atleast 10 feet around the structure. : : :.. 25.Blower doortest and-blown in insulation card shall be provided before C:.O: 26 A copy of the enem eacls.shall'be with-nermit at all tinter 27.. Copy of final insulation report shall be:provided with perinit before.finab . F.F.E.-Finished Floor Elevation - F:B.C-Florida Building Code 6�'Edition K.O.W.-Right of Way. A.D:A:-Americans with Disabilities Act N.E.C.=National Electric.Code(2011) 24-26-21-0100-00000-1240 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 18, 2018 Parcel ID 24-26-21-0100-00000-1240 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3229 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 See Plat for this Subdivision Taxable Value $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 124 OR 9767 PG 2864 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) Line -----Use DescriptionZonmg !Units_' IType Price __ !Condition Value__ — 1 0100_ SFR _ MPUD L6,000.00 .j _ SF _ 1_ $4.5_0 1_00 -$27,000_ 2 0100 SFR { MPUD j 600.00 SF $0.90 1 1.00 - �- $540 Additional Land Information Acres 0.15 Area 30ZH Code -- Residential Code HDRVLPI ITax Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _Extra Features (Card: 001 of 001) _ Line ---,------------------- -r------- ----- Tescription !Year _ Units !Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year !Book/Page _ _Type —__ _ IDO_R Code Condition Amount 07/2018 -_ 9767 / 2864 Warranty Deed_ I 055 _Vacant -j-Multi-Parcel Sale — 09/2011 ' 8606 3376 Warrant Deed 1 05 Vacant ` Multi-Parcel Sale 06/2010u ( 8360 / 1872 Certificate of Title I 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000001240 8/24/2018 ' PASCO COUNTY, FLORIDA Permit No. 20' Date PermittedE-2-7—TRE Builder Name/Owner Name L na-f- Control#' County Parcel No. 24-2(,2a 0 l00_CD0W_124C> SubDiv: OIGfGrt eve Address/Location -__ 322q l�recgyerca-or>�!e /ctw, E; { Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: -2r 37& Exempt ❑--(es ❑ No How Determined i' I Impact Fee Amount $.A b32.0 0 Zone No. TAZ: iJ; i. SCHOOL IMPACT FEE +` Account (056) Single-Family Detached House Amount (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [�] Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total t E:. Zone TOTAL AMOUNT $ Ak Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt [] Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT k Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION I PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not implyacceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner,on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY r. RECEIPT NO. DATE BY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Carrier Builder Name: Lennar Homes 0124 Street: 3229 Kresterbrooke Lane Permit office: City of ZephyrhiIls City,State,Zip: FL, Permit Number: 2,d (.S9 Owner: Lennar Homes Jurisdiction: 6}},24)& (0 l(6pc7 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sgft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d; U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1936.0 sgft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.68 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans andT S�Ap r - this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �'q, ' `' 40 Dave ,�lol�rcG� with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for771 .)! compliance with Section 553.908 * �, I hereby certify that this building,as g compliance designed, is in Florida Statutes. with the Florida Energy Code. �OZj wt t. .. OWNER/AGENT: BUILDING OF CI L: DATE: o DATE: - Compliance requires certification by the it handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 380,is not greater than 0.030 Qn for whole house. 6/13/2018 1:36 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Carrier Builder Name: Lennar Homes 0124 Street: 3229 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1936.00 ft 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sgft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rrn 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A -R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.68 PASS Total Baseline Loads: 61.53 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this __ p Code. calculation indicates compliance with the Florida Energy Code. F•' rrrrr.,:.'?�. ••: .';•�'�'= ,{O PREPARED BY: Dave AWch Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * �_ herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 P � - - with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL-. . DATE: DATE: / - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 F FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method' Project Name: 1941A1 sf ADS Carrier Builder Name: Lennar Homes 0124 Street: 3229 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611200 Design Location: FL',Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2 b.Frame-Wood,Adjacent R=11.0 307.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1936.00 ft 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.68 PASS Total Baseline Loads: 61.53 hereby certify that the plans and specifications covered by Review of the plans and 'THE.SxA .. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. rrrrr = "•;� „ �3 PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. fY Energy 9 P with the Florida Ener Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. J 6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 . . FORM R405-2017, INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1941AI sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 Lot# Owner Name: Lennar Homes Total Stories: I Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range BLOCKS Number Name Area Volume Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated / FLOORS yFloor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet ,uiap~On~=raou Edge mvumo" master =,=" " ^=., __ " " 1 __ zalab-On-Grade Edge/nsulatlio fami0rin 14.5n o 340.8 ft2 _ u o 1 _ aalau-Oo-Gvauo Edge|nsulaoo cafe 25.5u u 1e/ft2 u o 1 U _ 4a|uc~on'anmua Edge mvu|miu xu 13.5u o 182.3u" __ 1 n o U U � 6x13/20181:36Pm EnnmvGauga@)USA Section R4O5.4.1 Compliant Software . Page umG FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 1 0 0 11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 e� 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 e__ 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor.- Tested Tested Insul. (deg) 1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rrri 30 Blown 100 ft2 0.1 Wood 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood 6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8_ 0 136.0 ft2 0 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 _ 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 10 N=>NE Exterior J Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 _13 N=>NE Garage Frame-Wood o wic 11 12 0 8 0 96.0 ft2 0 0.23 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.Q ft2 0 0 0.6 0 _16 N=>NE Garage Frame-Wood laundry rm 11 7 5 8 0 59.3 ft2 0 0.23 0.01 0 17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _18 W=>NW Garage Frame-Wood foyer 11 16 4 9 4 152.4 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID-.Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>SW 1 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 2 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in None None 4 E=>SE 7 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 5 E=>SE 8 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 6 N=>NE 10 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in 4 ft 2 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft2 416ft2 43.7ft 8ft 1 6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000349 1772.4 97.3 182.99 .2641 6.5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr. 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftZ DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ftZ Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r [ j May X]Jun X]Jul rj Aug Se [ ]Oct [[ ]]Nov [[ ]]Dec Heatin Jan Feb Mar Apr [ May ]Jun ]Jul Au (�]Sep [ ]Oct [X]Nov [X]Dec Ventin Jan Feb X Mar A r [ May [ ]Jun [ ]Jul Aug [ ]Se [X]Oct [X]Nov [[ ]Dec 6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WID) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PIVI 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 Oft 0.3 master Default(8 lbs/sq.ft. ft2 ft 0.3 family rm Default(8 lbs/sq.ft. ft2 ft 0.3 cafe Default(8 lbs/sq.ft. ft2 ft 0.3 kit Default(8 lbs/sq.ft. ft2 ft 0.3 bdrm2 Default(8 lbs/sq.ft. ft2 ft 0.3 bdrm3 Default(8 lbs/sq.ft. ft2 ft 0.3 bath2 Default(8 lbs/sq.ft. ft2 It 0.3 bdrm4 Default(8 lbs/sq.ft. ft2 ft 0.3 0 wic Default(8 lbs/sq.ft. ft2 ft 0.3 privy Default(8 lbs/sq.ft. ft2 ft 0.3 o bath Default(8 lbs/sq.ft. ft2 ft 0.3 laundry rm Default(8 lbs/sq.ft. ft2 ft 0.3 foyer Default(8 lbs/sq.ft. ft2 ft 0.3 hall Name: Signature: Rating Compant: Date: 6/13/2018 1:36 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 6 of 6 2O17EPL DISPLAY CARD ������� ������ ��� K ���U ���U � ��8�%�U �� ENERGY PERFORMANCE~~"~��"��"=~~~- ��~~~ ~�^- x~�^ ~~v DISPLAY^^ CARD ENERGY PERFORMANCE INDEX* 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1.1 New(From�Plans) 12. Ducts,location&insulation level a)Supply ducts R__--6.0 2. Single-family ormultiple-family 2. Single-fami y b) Return ducts R6.0 dAHU location Attiu8ami|ynn 3. No.ef units(if multip|e4amiky) 3.___----Y_- 4.Number ofbedrooms 4. 4 13.Cooling system: Copouhy___L4.8 a)Split system 8EER15.l 5.|o this a worst case?(yau/no) 5. Yes_ b)Single package GEER______ c)Ground/water source SEER/COP _____ 8.Conditioned floor area(oq.ft.) O. ����_ d)Room unit/PTAC EER______ o)Cxher 7.Windows,type and area o)U4actor(weighted average) 7o. 0.551 _ b)Solar Heat Gain Coefficient(GHQC) 7b. 0.323 _ 14.Heating system: Capacity___24.6 o)Area 7o` 15I.3_ a)Split system heat pump H8PF_ 8.5 W Single package heat pump HSPF______ 8.SkyligNo o)Electric resistance C0P_______ o}U4actoc(weighted average) 80. N&4 d)Gas furnace,natural gas AFUE_______ b)Solar Heat Gain Coefficient(GHGC) 8b` NA_ e>Gas furnace, LPG AFUE_______ �Other Q. Floor type, insulation level: a)Ghsb'on'grada(R+m|ue) 9a` 0.0__ b)Wood,raised (R- a|uo) Qb. 15.Water heating system c)Concrete,raised(R' o|ue) Qc. a}Electric resistance EF1.U5 b)Gas fired, natural gas EF______ 1O.Wall type and insulation: c)Gas fired, LPG EF______ A. Exterior: d)Solar system with tank EF______ 1.Wood frame(Insulation R'vo|ue) 18A1` o)Dedicated heat pump with tank EF____ 2.Masonry(insulation R'vduo) 1OA2. 4.1 0 Heat recovery unit HeatRao%______ B.Adjacent g)Other 1.Wood frame(insulation R' o|ue) 10811._ 11.0__ 2.Maannry(|nau|uUonR'vm|uo> 1O82`_______ 10.HVAC credits claimed(Performance Method) 1i.Ceiling type and insulation level o)Ceiling fans a)Under attic 11o. _ 30.0 _ b)Cross ventilation �No b)Single assembly 11b. u)Whole house fan No � ci Knee walls/skylight walls ' 11o` d)K8ukizune cooling credit d)Radiant barrier installed 11d. Ng e)N|ultizono heating credit f) Programmable thermostat Yes *Label required by Section R303.11.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. |certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Date: Address uf New Hom City/FLZip: 6n3/20181:37:28PM snomyGauaeO USA 8.O.ux'Flanas2017rsC0ux Edition(2m17)Compliant Software Page 1uf1 Job: 1941AI sf ADS Carrier 'Building Analysis Date: 5/1012018 Entire House By: Dave Bayonet Plumbing Heating and Air For: Lennar Homes Project Informatio.n Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US, Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28'N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft' Btuh % of load Walls 5.6 7036 25.5 ucts Glazing 30.2 4709 17.0 Wal u"s Doors 23.5 466 1.7 nfiltration Ceilings 1.3 2429 8.8 Floors 3.5 6726 24.3 Infiltration 2.1 3056 11.1 Ducts 3221 11.7 Piping 0 0 Glazing Floors Humidification 0 0 ther Other Ventilation 0 0 Ceilings Adjustments 0 1 Total 1 1 276411 100.0 am • Component Btuh/ft' Btuh % of load Walls 2.8 3500 13.3 Walls Glazing 56.7 8852 33.7 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.8 Floors 0 0 0 Infiltration 1 0.5 684 2.6 Ducts 3628 13.8 Ventilation 0 0 Glazing Ducts Internal gains 5915 22.5 Blower 0 0 Infiltration Adjustments 0 Total 26302 100.0 Other Ceilings I Latent Cooling Load=4180 Btuh Overall U-value= 0.103 Btuh/ft2_OF Data entries checked. 41- wrightscioft- 2018-May-I0 13:23:50 Right-SuiteO Universal 2018 18.0.16 RSU05714 Page 1 AC0. _.quipment\1941 sf ADS template 3ton Carriecrup Calc=MJ8 Front Door faces: E Project Summary Job: 1941A1 sf ADS Carrier Date: 5110/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment'Load Sizing Structure 24421 Btuh Structure 22674 Btuh Ducts 3221 Btuh Ducts 3628 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27641 Btuh Use manufacturer's data y Ratelswing multiplier 1.00 Infiltration Equipment sensible load 26302 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3519 Btuh Ducts 660 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cooling (none) Area (ft2) 1936 1936 Equipment latent load 4180 Btuh Volume(ft') 16360 16360 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30482 Btuh Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC536AO0300 Cond 25HBC536AO0300 AHRI ref 9155179 Coil FX4DNF037L AHRI ref 9155179 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 26 OF Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.043 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point=26 OF Backup: n/a n/a Input= 0 kW, Output=0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrigtttsoft® 2018-May-10 13:23:50 Right-Suite®Universal 2018 18.0.16 RSU06714 ACCK ...equipment\1941 sf ADS template 3ton Garriecrup Calc=MJ8 Front Door faces: E Pagel Wanual S Compliance Report Job: 1941AI sf ADS carder Date: 511012018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26302 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4180 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30482 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's, Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29580 Btuh 112% of load Latent capacity: 5220 Btuh 125%of load Total capacity: 34800 Btuh 114% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 27641 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26331 Btuh 95%of load Capacity balance: 26 oF Supplemental heat required: 1310 Btuh Economic balance: -99 oF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 'F Meets all requirements of ACCA Manual S. Ak� * wrightsaft, 2018-May-10 13:23:50 Z& Right-SuiteS Universal 201818.0.16 RSU05714 Page I ...equipmentX1941 s!ADS template 3ton Carriernip Cale=MJ8 Front Door faces: E SKETCH ONLY SEC. 24 TWp. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS; LOT 124 HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89-40-43- E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6§09_.QCLSQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =_L55- —SQ. FT. _0 UNDERGROUND FOOTER, STEM WALL, AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY FT. 1-1 UNDERGROUND U11LITIES ARE NOT LOCATED OR GARAGE 417—SQ. FT. 11 SHOWN. LEGEND: COVERED LANAI =___t!�A—SQ- FT. = PROPOSED DRAINAGE FLOW PATIO = 23 SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE CONC. DRIVE = 475 -SQ. FT, < NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & CONC PAD =__ _.._._SQ. Ft 6 PRIVATE SIDEWALK =__Z%_SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS PAGE INDICATES THAT PLAT IS IN NOTES: Q. FT. t PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = A PROPOSED PAD ELEVATION SOD = j0_5Q__SQ_ FT. CHANGE AND/OR REVISION. FRONT SETBACK = 20' CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK10' OFF LOT AREA CALCULATIONS ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK 10' RIGHT OF WAY = L20-00 SQ. FT. DRIVE APRON = 144 --SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK = 240__SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD =__3_36__SQ. FT, TO PROPERTY LINE. TOTALS 10' DRAINAGE/UTILITY EASEMENT AREA =__2320.00 SQ. FT. DRIVEWAY =___0_9SQ. FT. SIDEWALK =__269___SQ. FT. SOD =_-AN2 SQ. FT. PLAT LOT 125 PLAT LOT 100 BOUNDARY BOUNDARY HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) S 89*36'58" E 110.00' 2 Lit-A/VV— z 29.67-1 C) 0 uj" z-1 0 (0 LOT 101 Lji - Ld W HIDDEN RIVER PHASE ONE A 0 U)z 04 0,LL OfI (PLAT BOOK 74, PAGES 101-121) (N _0 0 W_0 tN7 0 CL < q Fx_j ry> — p ........I....... 0 arc, ui 20.50* to m . 04 ZED 0 ryw 0_ 0 65'-0"- Lie 1 0 20.50, z 2 E) ...... 94 k : . .... . T N 89*36'58" W 110.00' 25 LOT 102 HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) cli LOT 123 00 —PRM(P) 00 00 PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 73.40' A! GARAGE AREA: 72.86' �4 DESCRIPTION: ELEVATIONS REFERENCED TO In LOT 124, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA 10 OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. i APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 Project Number: Square Feet: 6600.00 t LENNAR HOMES 4 LEGEND: ul (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, qt= CENTERLINE, A/Q= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, T F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FiP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2' IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F= WOOD FENCE r Drawn By: JOHN R.BEACH&ASSOCIATES,INC. SMS SURVEYORS AND MAPPERS Checked t 911 WEST ST. PETERSBURG DRIVE By: ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: "=30, NOT VALID WITHOUT THE SIGNATURE AND jDate: PLOT PLAN 6/21/18 ACS 2 THE ORIGINAL RAISED SEAL OF A FLORIDA /SIG?VATU DATE HN LICENSED SURVEYOR AND MAPPER N R. B H '.�L 1% 4 Revisions: FLORIDA REG. SURVEYOR No. 2984 LB#4493 JEFF M. HARTL PROFESSION URVEYOR & MAPPER No.7123 Ff EL. FF EL 30 74M 121 A A r EL FF-F-Z7L 361 A 99 126 �A 14 ;.o r- -7--0-------;f T' . 0 ----------- MASE I .0 , . ....... 71 100 125 773 Z hogk— LLI 33 FFEL 10 V, A 4— FFEL i FF EL .WFFA .34 73M AF.S. rFF 7 102Fes 123 FA 1103 Nj a t4 JS 12 I FFEL 36 104 121 E. --Zzzf E-H I FF 33. >0 A 06 A" A 38 \72.40/ FFEL FFIL I 2M657 =A I FF F-5L \7=/ �ZA FF EL FFEL nm Moo A A 119 FF-F-M7 106 FF EL I 72.00 Ff EL i FPM i V" A I T225 A 07 118 A FFEL 108 V rWS7 oo. 711. A A , 79 N M5 r FF ME FF M- . 110 rzze- I , / " -1 A imm ohm' ATC E tV' SHE lm Kmfay-Hom SCALE Is NOTED I and ASsodates., 10C. MESIGPIM, alf SP HIDDEN RIVER SUBS 1-HORN AND ASSOCtATE-5, INC. BY r, api4ywy-s-, PLORIGA '135-42 SP 1-0400 FAX (013) -782-497E -HDRN,CDM CA (T-l0!3rl5;?0 C17Y OF ZEPHYRHILLS CLC qA FF EL =A 73 e93 FF EL A \7a2S 0 o� o City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: Permit Type: �p (j l� c ?ir 37 — Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switz 'r— ans Examiner Date tra and/or omeowner quired when comments are present) I(IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIII IIII 2018147349 Rcpt: 6891 282 IReC0.00-00 DS: 0.00 08/29/2018 C. F. , Dpty Clerk rAULR S.0'NEIL,Ph.D.pPR�SCO CLERK & COMPTROLLER 080R 0102 24 EIK � �`J m PG 1664 Permit No. Parcel ID No 24-26-21-0100-00000-1240 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 124 Street Address: 3229 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, L.L.C. Name 4600 W Cypress St, Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: F-- N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FIL 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS _ Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 13 day of March by Steve Robert Smith as Vice President (type of authority,e. ,trustee,attorney in fact)for Lennar Homes. LLC (name of party on b half m instrument was executed). Personally Known 2 OR Produced Identification❑ Notary Si . Type of Identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ELISSAM.HOLLERAN Signature of Na ural Person Signing Above Cnnm189100 FF 88583T EXPIres June 8,2020 wpdata/bcs/bcsform:E SenderlhruTroyFolnln�urfneet003i5dOtp 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3229 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-21-0100-00000-1240 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20159 Da a 8D 12/17/2018 ISSU BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE PASCO COUNTY DA DEVELOPMENT SERVICES .L is C _87Z11 Citizens Drive Date. 11/7/2618 COUNTY FL D)*�A New Port Richey,FL 34654 01'1-:N SPACFS'1,18RINr PlAcrS, 727-841-2411 NOT A PERMIT Receipt#: 1807123 FEE DESCRIPTION ACCOUNT CODE. UNITS, INVOICE# FEE AMOUNT PAID RECEIPT 9 DATE Impact Fee Residential Solid 24501007329010 1.00 1400895 $12.58: $12.58 1867123 11/6/18. Waste Single Family Permit#201 59. TOTALS. $12.68 $12.58 Receipt Paid By Check# CC Auth# Cashier ID -Workstation Receipt Date Amt Paid 1807123' Chock 1076142 556 BCCCP05W 11/06/2018 $12.58 Total Payments: $12.68 Pavor Addr,@ss Phone -,Lehhar Homes,LLC 3229 Kresterbirooke Lane ,Comments: 24-26-21-0100-00000-1.240 ,While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or e-check less,NOT shown above,Is collected by First Billing payment services. MyReports/r.eports//PASCOPROD/PASC0/R6celptPOS V6. t 1 lf7/2018 — M Page 1 of 1