Loading...
HomeMy WebLinkAbout18-20164 CITY OF ZEPHYRHILLS i' 5335-8TH STREET (813)780-0020 20164 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20164 Issued: Address: 302&KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343 1 1.90 Tal Fees: 8,442.97 Subdivision: HIDDEN RIVER Amount Paid:, 1 ��RDate Paid: �- 1�-��J Parcel Number: 24-26-21-0100-00000-1220 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 SEWER CONNECTION RESIDEN" 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections ft4quired F O R 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. " A& - &�_ f"�* CONTRACTCTRS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT'CARD FROM WEATHER CITY OF I / / / BUILDING ZEPHYR14ILLS DEPARTIMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT f 32ncr�lskk_ook ..:� --I E D 61 THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE cover or cause to be covered,any part of the work with flooring,lath,earth 78�-002� FOR E-IN P N or other material,until the proper inspector has had ample time to approve the installation. , OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR { r t Lennar Homes-3205 Kresterbrooke Lane,3,046 sq ft SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,842.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S : $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: 18,442.97 Lennar names-3205 Kresterbrooke Ln:3,046 sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $, 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIV—EW­AYJ $ 40.00 BUILDING: -$ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,847.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,447.97 Sin le R i Dwelhn g Y g.. Pla n Review.Comments: 1: F.F.E. shall be a rninirnum.of 8" above.the road'elevation and an engineered site plan. . I. Lots.shall be'graded to comply with R401.3 of the F.B:.C. -3.- Coin :tes required action t _ if 24" or more of g y p.,fill dirt is brought.in at ari one dace. . . .. : .. . . 4:. :Tie iri survey-required before pouring concrete.. .5.. Driveways:require a R:O.W.use permit:: All 4:sides of driveway thru the sidewalk shall have. expansion material: 6.. All,setbacks.shall be met.. 7. ;All.property:markers shall be,uncovered and marked.at time-of first inspection: 8:. :All A.D.A. requirements shall be met.. . 9.. Na electric. .plumbin g,g,mechanical,,or framing shall be covered without an inspection.and approval first. . 10. All Garages shall.comply with.section R302.6:of the:F.B.C.:.(Fire Separation). 11.Appliances shall not be installed in-a'location where subjectto.mechanical damage:uriless. protected by approved.barriers: M303.4 of the F.B:C. 12. Water heaters shall comply with section.P607.3 of the F.B.C: 13. Foundatiori supports for.A/C shall be raised at least 3" above finished grade. M1308.1. 14. Return air in all bedrooms. F.B.C. M.1620.4.: . 15.' SMoke detectors are.to be installed in accordance with:R313:.1 ofthe F.B.C. 16: All glazing requirements are.ao be in accordance with R308.4,of the F.B.O. 17. All means of egress are to be in accordance with R311.of the F.B.C. 18. `.`Green gypsum board shall.not be used:as a backer.in showers or tubs. R702.4.2.F.B.C. 19. Combination-t ype AFCI breakers are,required.at all locations requiring an AFCLtype breaker: 20: Carbon monoxide.alarms:will.be required in.new construction that uses fossil-burnin' heating :or appliances or an attached garage:. They shall be installed in accordance with.the F.B.C: . 21. All plumbing,mechanical,:and electrical shall be separate from unit.to.unit. This includes all, underground plumbing and electric. -22. All 2016:N.E.C: Codeswill be enforced.. - 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C .24.. In accordance:.with.the Land Development Code; lots.shall be sodded before final at least 10.. feet around:the structure.: . 25. Blower door test and blown in insulation card shall be provided before C:.O: 26.A copy of the energy edels.shall be with Permit-at all times 27.. Copy of final insulation retvort shall be.Provided)4itli permit-before rinab . F.F.E.-Finished Floor Elevation F.B.C=Florida Building Code 6t'Edition R:O.W.-Right of Way A.D:A:-Americans with Disabilities Act N.E.C.-:National Electric Code(2011) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780/ Building Department 7 Date Receive'd Phone Contact for Permitting 813 363 2891 Owner's.Name Lermar Homes,-LLC Owner Phone Number 1-813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS ' LOT 1220 auoD|mmom Hidden River Phase One A I p4RosL|o# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW cowsrx ADD/ALT �--� 0|oN ' �—� �—� DEMOLISH* P �� _ INSTALL �_� REPAIR ' PROPOSED USE 8FR �-7 COMM �--1 OTHER TYPE opCONSTRUCTION e�oc� �—\ rRxw� �--� oTe�� F--1 DESCRIPTION orWORK Single Family Residence Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF aq FOOTAGE����� � HEIGHT 12 Story BUILDING �—� AMP SERVICE OpLUMa{N8 , J­71 Ij yMECHAW|CAL VALUATION OF MECHANICAL INSTALLATION [— ~ �--�omS h��\� ROOFING �—1 aPsomcrY �--� VT*sn �� �� FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA Yso O � V | � au|Lmsn COMPANY Lermar Homes,LLC m|oN/TumE o /��L_] reeouxmsx [_y/N_j Address License# sLsn7R|c|Am COMPANY Edmonson Electric, Inc. SIGNATURE m nse/mEnso I.Y/ NL] pseounns^ [_Y/N_] Address PLUMBER COMPANY =Bayonet Plumbing, lleating &AC, Inc m|mN4TumE REGISTERED rssounnsx ���--�--- ' Address ` ummue# MECHANICAL SIGNATURE REGISTERED [`// N peeounnsx _ Auumoe License# OTHER COMPANY m/om4TuRE REGISTERED rseuunnsu Address L�enne� xumxxmmnxnnxxnnnmxxxwxx000xmxxmnxxmxxmmunwnnnxuxnmnnwxxmmxxmxxumoum FCC RESIDENTIAL Attach Cq Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date, Required nnuUo.Construction Plans,Stonnwater Plans wV Silt Fence installed, Sanitary Facilities&1uumpomcSite WhrkPom­iit for subdivisions/large projects COMMERCIAL _Attach(q complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permitfor new construction. Minimum ten(1O)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets vf Engineered Plans. ! ~"^PnnPERTv SURVEY required for all NEW construction. / -- "'^=^"="' Fitt out application completely. Owner m Contractor sign back o,application,notarized If over$zsnu'o Notice uf Commencement|nrequired. (AC upgrades over$7eno) � Agent(for the contractor)or Power of Attorney(for the owner)would be someone With notarized letter from owner a.uthorizing same ' OVER THE COUNTER PERMITTING (copy u,contract required) ' nomofs if shingles Govem Service Upgrades A/C renuoo(PluVGunvey/pootage) Driveways-Not over Counter ifon public muowuyo'neodaROW OTCE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deeed" restriptions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any , applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised-to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block"-of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is'not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number $9-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application-is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development"regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering, Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem-wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be-construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N TICE OF COMMENCEMENT. FLORIDA JURAT(F.S.11 )) _. OWNER OR AGENT CONTRACTOR Subscribed and sworn (or a irmed)before me this Subscribed and savor o(or affirmed)before me this t 0-Jun-1 o by AsMee Callahan 13-Jun-1e by Ashlee Callahan Who is/are personally known tome or: Who is/are personally known to me or entification. tification. Notary Public Notary Public Commission No. FF98537 _ Co No. 98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped _ �LI@�i��►N�4�II�A1V =row I� -e9� i4radu -tl',2 d +��W19�'GI! � -- - Yap, City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: cPermit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: El This comment sheet shall be kept with the permit and/or plans. Kalvin tz Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) 1 PASCO COUNTY, FLORIDA 7 Permit.No. 2-016: _ Data Permitted Builder Name/Owner Named�- Control# { County Parcel No, _2 7fo 2�—Ut(7D- (�-j2?-0 SubDiv: PWA& e�^ M Address/Location 320,5 t eJ4eA La.t z1 p' Classification/Type of Use Sa 2 c` 4' TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑des ❑ No How Determined t.% Impact Fee Amount $. 632 'Zone No, TAZ: I, SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee i Exempt ( Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ '761-56 ;;.. Exempt ❑Yes ❑ No How Determined- ' `f LIBRARY FEE r. Land Accounf Land Credit Land Total 4I' Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount . RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION I„ PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE r BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY r` Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner,on notice of this assessment and the conditions of payment for same. t`. DATE RECEIVED BY RECEIPT NO. DATE BY t 24-26-21-0100-00000-1220 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive Saturday, August 18, 2018 Parcel ID 24-26-21-0100-00000-1220 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3205 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 See Plat for this Subdivision Taxable Value $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 122 OR 9767 PG 2864 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) 7 -----,- - -�;- ---- - -- ---- Line Use _ -iDescription!Zoning Units �IType ,Price Condition {Value _ 1 0100 SFR MPUD 6,000.00 I SF j $4.50 1.00 ; $27,000 2 0100 SFR 1 MPUD ; 600.00 1 SF - $0.90 1 1.00 $540 - _ Additional Land InformationFEMA Acres 0.15 [TaxArea1 30ZH Code I Residential Code HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line - Description Units ;V_ alue — No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year 1Book/Page ,Type _ - -rDOR Code ;Condition TAmount -- 07/2018 9767 / 2864 ' Warranty Deed i 05 Vacant Multi-Parcel Sale 09/201.1 8606 / 3376 Warranty Deed _ 05 __ Vacant _Multi-Parcel Sale 06/2010 8360 / 1872 j Certificate of Title 12 Vacant I J $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000001220 8/24/2018 PLOT PLAN SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. NOT A BOUNDARY SURVEY LOT 122 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89-40'43" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS 1.� MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6600.00 SQ. FT, EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = M%3 _SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 35 Q. FT. M UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 427 Q. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI =__N_& SQ. FT. SHOWN. ww� = PROPOSED DRAINAGE FLOW PAT10 =_23 -SO. FT. (00.00) = PROPOSED GRADE CONC. DRIVE = 408 SQ. FT. w DO NOT SCALE THIS PRINT. DIMENSIONS AND /E-00.00 EXISTING GRADE A C & CONC PAD = 18 SQ. FT_ U NOTES TAKE PREFERENCE. = PRIVATE SIDEWALK = 31 SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: IMPERVIOUS =�31 PAGE INDICATES THAT PLAT IS IN LOT GRADING TYPE = A _ 2035 -SQ. FT.SOD 4565 gQ, FT. PRELIMINARY STAGE AND IS SUBJECT TO = PROPOSED PAD ELEVATION = CHANGE AND/OR REVISION. FRONT SETBACK = 20' SIDE SETBACK = 10' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON REAR SETBACK = 10' RIGHT OF WAY = 720.00 S0. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON = 144 SQ. FT. PUBLIC SIDEWALK = 240 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES SOD =__336 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. TOTALS + = 10' DRAINAGE/UTILITY EASEMENT AREA =,7320.00 SQ, FT. DRIVEWAY = 55_2 SQ. FT. SIDEWALK = 271 SQ. FT, SOD = 4901 SQ. FT. I PLAT LOT 123 PLAT LOT 102 I BOUNDARY BOUNDARY HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) �sJ\ _ S 89"36'58" E 1 10.00' _ A� 2sa ' W o :o o: i o ........................................ __ O 46.50' ......-00 25.54' 0 w w O c.7 43-0. o zT O z LOT 103 W ��� N .--.•20.�0'-••-- O ¢� HIDDEN RIVER PHASE ONE A O N_ o (PLAT BOOK 74, PAGES 101-121) N F o a z I of 0 O a aa�Q `Ir N a �� p- �o N or :s mzm CNI LL LLI 0 O Lj .o .......25.51�'....... o• V/:o o: NwN N 89'36'58" W 1 10.00' yam 250 LOT 104 - HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) N LOT 121 a �+ `PRM(P) [V co '•I O N PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 73.00' jDESCRIPTION: GARAGE AREA: 72.46' ELEVATIONS REFERENCED TO m LOT 122, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA o OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. w a ni APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9 30 1992 Project Number. Square Feet: 6600.00 t LENNAR HOMES,:, Z LEGEND: - (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q.= CENTERLINE, A/C= AIR�CONDITIOIIFR,' /C=-BACK OF CURB, C/S= O CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED,.F_/P=EOGE-OF.PAVEMEN . ESM'T= EASEMENT, = F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD;'FNBD==FOLINCLNAii -&'AISK'\FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP-=PERMANENT CONTROL,PQ!NT,7rRM= PERMANENT w REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET-NAIL & DISK, TBM= TEMPORARY BENCHMARK, m U P= UTILITY POLE W F= WOOD FENCE v SMS JOHN R.BEACH&ASSOCIATES,INC. Drawn By: - _ -- >_ SURVEYORS AND MAPPERS 911 WEST ST. PETERSBURG DRIVE Checked By: u ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Sal:1 / = db/ NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 6/11/18 ACS o THE ORIGINAL RAISED SEAL OF A FLORIDA SIGNAT E DATE LICENSED SURVEYOR AND MAPPER JOH R. BEACH Revisions: F RIDA REG. LAN SURVEYOR No.' 2984 LB 4493 N FF M. HARTLEY LL PROFESSIONAL S EYOR & MAPPER No.7123 'Fr-EL T Fr 0 FF-F-EM 74 2=3 I \74,90/ ' A 127 A A A L tu - ...... ....... ------------- FF EL A 126 1, 99 �A -0 41 L —ESEE: 0 2- :0 75-07 100 125 A M r--————— —— Y. I A A A FFF EL I FFEL ' A I FFEL 1-mW f FF EL 102 1-23 L AMUS/ ,A4 "F PU 17 FFL, 35 MFFrL 103 W 7, L t A I r FFEL 36 . 104 121 I A L —————— FF EL 37 12-M 120 A I A .38 N381 gn FF E"L I FF EL Tim FFF XL 1 8, A A 106 119 A N �15 FFEL I FF EL QU V 07 A 118 7175 ti A lo8 FF A 79 A A 1 17 FF M- 110 MEN IM N A LAJ �VE)" SHE 'm Kmfey-Hom SCALE AS NOTED I and Associates', Inc. MMIGHM i3y SP HIDDEN RIVER SUBS '-HURIN AND ASSOCIATES, INC, URNOIN By ZEPHYRNLLS, FLORIDA 33542 :-04C5D FAX (n13) 782-497E CKECKED BY MORN.CUM CA OCIOCEIR90 CLC C17Y OF ZE-PHYPHU-S.- - W-7— EL W EL, A 7 -9Z 73 TA L 0 44 W. 3 IL 1z tu EWA ffA _7A I-F-VEK-1 Moo A� A A111111111111111111 111111111111111111111111111111 IN l l 1111 2018,4734 Rcpt:1986282 Rec: 10.00 DS: 0.00 IT: 0.00 08/29/2018 C. F. , Dpty Clerk PRULR S.0'NEIL,Ph.D.PASCO CLERK & COMPTROLLER 08 OR 8K 1 7 02 m PG 1662 Permit No. Parcel ID No 24-26-21-0100-00000-1220 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 122 Street Address: 3205 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. - Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: _ N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes: Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS ign�f Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 13 day of March ,by Steve Robert Smith as.Vice President (type of authorit r,trustee,attorney in fact)for Lennar Homes, LLC (name of party n beha om instrument was executed). Personally Known E OR Produced Identification❑ Notary Sig ture Type of Identification Produced Name(Print) ISSa olleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of pe'ury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ELISSAM.HOLLERAN ffSignatureral Person Si nrn Above Cemmissl0n#FF 08583TSigning ExFlres June 8,2020 wpdata/bcs/bcs form: ,"d� sondednru Troy Fain lnsumneet004*701D FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575131 sf ADS Carrier Builder Name: Lennar Homes 0122 Street: 3205 Kresterbrooke Lane' Permit Office: City of ep�lohThiEs City,State,Zip: ,FL, Permit Number: � l � Owner. Lennar Homes Jurisdiction: ` Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor. Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.33 b. U-Factor. Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.58 33.33 ft2 b.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.316 14.Hot water systems 8. Floor Types (1533.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=11.0 427.00 ft2 None c.other(see details) R= 13.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 75.83 PASS Total Baseline Loads: 75.77 I hereby certify that the plans and specifications covered by Review of the plans and .a T STAA this calculation are in compliance with the Florida Energy specifications coveredl by this p Code. I calculation indicates compliance' with the Florida Energy Code. PREPARED BY: Dave Mich Before construction is completed 41 .. DATE: this building will be inspected for compliance with Section 553.908 *., = ° . hereby certify that this building,as designed, is in compliance Florida Statutes. !, with the Florida Energy Code. .SUN C�f it nn i r OIj it C WV�_ F' OWNER/AGENT: BUILDING O ICLAI DATE: 14e, DATE: - Compliance requires certificatio the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accorceance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with'a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 6/13/2018 11:51 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575131 sf ADS Carrier Builder Name: Lennar Homes 0122 Street: 3205 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1489.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a.Central Unit 18.0 SEER:15.00 b.Central Unit 24.0 SEER:15.50 c. U-Factor. � Dbl,U=0.58 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.316 14.Hot water systems 8. Floor Types (1533.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=11.0 427.00 ft2 None c.other(see details) R= 13.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 75.83 PASS Total Baseline Loads: 75.77 I hereby certify that the plans and specifications covered by Review of the plans and TEE STA this calculation are in compliance with the Florida Energy specifications covered by this O� Code. calculation indicates compliance �,;,''� _',- s+, with the Florida Energy Code. E, PREPARED BY: 'Dave Auiich Before construction is completed � •-�r ' � �• DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. C k . OWNER/AGENT: BUILDING OFFICIAI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 6/13/2018 11:51 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0122 Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3205 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.NIA R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.30 a.Central Unit 18.0 SEERA5.00 b.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.58 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.316 14.Hot water systems 8. Floor Types (1533.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor over Garage R=11.0 427.00 ft2 None c.other(see details) R= 13.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 75.83 PASS Total Baseline Loads: 75.77 hereby certify that the plans and specifications covered by Review of the plans and ;O VC os'1q? this calculation,are in compliance with the Florida Energy specifications covered by this Code. : i calculation indicates compliance ��+�;,, '' `===�`,:q• ,�s+ with the Florida Energy Code. ti• 7rir. Y?. -.,;, .,;e��,�O PREPARED BY: Dave Aupich Before construction is completed .;I DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. ' with the Florida Energy Code. QD WF OWNER/AGENT: BUILDING OFFIrIAl IV////�/ DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1'. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 6/13/2018 11:51 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R4.05-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 2575B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2582 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1093 9399.8 2 Block2 1489 11912 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1 st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 — 0.3 0 0.7 2 Raised Floor 2nd Floor 13 ft2 11 0 0 1 3 Floor over Garage 2nd Floor ____ ____ 427 ft2 11 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1489 ft2 N N 6/13/2018 11:51 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0 _ 5 N=>E Garage Frame-Wood 1st Floor 11 20 8 8 173.3 ft2 0.23 0.01 0 6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0.23 0.01 0 7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0.23 0.600000 0 8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0.23 0.6 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0.23 0.600000 0 10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0.23 0.600000 0 11 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 3 S=>W 11 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 5 N=>E 7 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 S=>W 9 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 7 W=>N 10 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>E, 7 Metal Low-E Double Yes 0.56 0.3 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 10 N=>E 1 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds , None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 41 ft 8.6 ft 1 6/13/2018 11:51 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 256.71 .3396 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 18 kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 43.7 cfm 0.04 0.60 1 1 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 59.6 cfm 0.04 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]]Jan [[ ]]Feb [[ ]]Mar [ ]A r [ ]Ma rl Jun [X]Jul [X]Aug Se [ ]Oct Nov [ ]Dec Heatin [X]Jan (X]Feb [X]Mar [ ]Apr [ ]May Jun [ ]Jul [ ]Aug Sep [ ]Oct x Nov' [X]Dec Ventin [ ]Jan [ ]Feb X Mar [X]A r [ ]Ma Jun [ ]Jul [ ]Au Se [ 1 Oct X Nov [ ]Dec 6/13/2018 11:51 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT 'thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 1st Floor Default(8 Ibs/s .ft. 0 ft2 0 ft 0.3 2nd Floor Name: Signature: Rating Compant: Date: 6/13/2018 11:51 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5 2017.EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts,location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/2nd Floor 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 42.0 a)Split system SEER varies 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2582 d)Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.556 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.316 14.Heating system: Capacity 41.7 c)Area 7c. 175.6 a)Split system heat pump HSPF varies b)Single package heat pump HSPF 8. Skylights c)Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 11.0 15.Water heating,system c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10132. IP.,HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be completed bas n i stalled code compliant features. Builder Signature: Date: 06/13/18 Addres/NHome: 3205��resterbrooke Lane City/FL Zip: . FL ZeFhyrhills,FL 33540 6/13/2018 11:53:00 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Anal Job: 2575B1 sf ADS carrier g ySIS Date: 5/1/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.5 5191 31.9 ucts Glazing 30.2 2683 16.5 nfiltration Doors 21.2 432 2.7 wall Ceilings 1.7 60 0.4 Floors 4.1 4478 27.5 Infiltration 1.9 2039 12.5 Ducts 1400 8.6 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors Other Adjustments 0 Total 16284 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 2641 23.2 Intenr al Gains Glazing 56.3 5004 . 44A walls Doors 16.6 338 3.0 Ceilings 2.0 67 0.6 Ducts Floors 0 0 0 Infiltration 0.4 454 4.0 Ducts 1655 14.6 Infiltration Ventilation 0 0 Other Internal gains 1200 10.6 Doors Blower 0 0 Adjustments 0 Total 11360 100.0 Glazing Latent Cooling Load= 1237 Btuh Overall U-value= 0.150 Btuh/ft2-°F Data entries checked. ` -Of&- =ightsc ft- 2018-May-01 09:33:44 ^�^•� ^ � Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ent%2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Building Analysis Job: 2575B1 sf ADS Carrier g Y Date: 5/1/2018 upper floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Co,nditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb ff) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 3.8 4204 32.8 gas Glazing 30.2 2608 20.3 Doors 0 0 0 Wall Ceilings 1.3 1868 14.6 Floors 0 0 0 nfiltrafion Infiltration 1.9 2299 17.9 Ducts 1846 14.4 Piping 0 0 Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 12825 100.0 Component Btuh/ftz Btuh % of load Walls 2.7: 3035 16.8 !Wall Glazing 53.0 4581 25.4 Doors 0 0 0 Internal Gains Ceilings 1.7 2583 14.3 Floors 0 0 0 r Infiltration 0.4 512 2.8 Ducts 2137 11.8 Ventilation 0 0 Glazing Internal gains 5213 28.9 Blower 0 0 Ducts Adjustments 0 Infiltration Total 18061 100.0 Ceilings Latent Cooling Load= 3191 Btuh Overall U-value= 0.083 Btuh/ft2-OF Data entries checked. -�- wr.9htsc ft- 2018-May-01 09:33:44 ^�^•t w u-,PM Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..ent\2575B sf ADS template 1.5-2 ton Carrier.rup Cale=MJ8 Front Door faces: E Project Summary Job: 2575B1 sf ADS Carrier ry Date: 51112018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14883 Btuh Structure 9705 Btuh Ducts 1400 Btuh Ducts 1655 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16284 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11360 Btuh Method Simplified Latent Cooling Equipment Load Sizing ' Construction quality Semi-tight Fireplaces 0 Structure 942 Btuh Ducts 294 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftt 1093 1093 Equipment latent load 1237 Btuh Volume ') 9654 9654 Air chanes/hour 0.29 0.16 ; Equipment Total Load (Sen+Lat) 12596 Btuh Equiv AF(cfm) 47 25 . Req. total capacity at 0.85 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC518AO0300 Cond 25HBC518AO0300 AHRI ref 9154643 Coil FB4CNP025L AHRI ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300 Btuh Heating output 17700 Btuh @ 47°F Latent cooling 2700 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 Cfm Actual air flow 600 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 30 OF Backup: Input=4 kW, Output= 15295 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2018-May-01 09:33:44 ^�^•� ^•• ��^p Right-Suited Universal 2018 18.0.16 RSU05714 Page 1 ACCA ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Cale=MJe Front Door faces: E Project Summary Job: 2575B1 sf ADS Carrier J ry Date: 5/1/2018 upper floor By: Dave Bayonet Plumbing Heating and Air Proiect Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10978 Btuh Structure 15924 Btuh Ducts 1846 Btuh Ducts 2137 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12825 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18061 Btuh Method Simplified 'Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2812 Btuh Ducts 379 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1489 148g Equipment latent load 3191 Btuh Volume(ft') 11912 11912 Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21252 Btuh Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Capacity balance point= 16 OF Backup: Input= 3 kW, Output= 11787 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2018-May-01 09:33:44 �� ^�^•� ^—��-w� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ACC, ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 2575B1 sf ADS Carrier Date: 5/1/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 12596 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 135% of load Latent capacity: 2700 Btuh 218% of load Total capacity: 18000 Btuh 143% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 16284 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 13453 Btuh 83% of load Capacity balance: 30 OF Supplemental heat required: 2831 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF Meets all requirements of ACCA Manual S. wrightsoft- 2018-May-01 09:33:44 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 �'M ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 2575B1 sf ADS Carrier Date: 511/2018 upper floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 18061 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 3191 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 21252 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 113% of load Latent capacity: 3600 Btuh 113% of load Total capacity: 24000 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 24000 Btuh 187% of load Capacity balance: 16 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. Wrightsaft® 2018-May-01 09:33:44 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ...ent\2575B sf ADS template 1.5-2 ton Canier.rup Calc=MJ8 Front Door faces: E LENNAM August.27,2018 „ City ofZephyrhills- Building Department 5335 81h Street Zephyrhills, FL 33542 813-780-0020 Re: Authorization Letter I,Steve Robert Smith, Florida State License number CGC1518166 hereby authorize the following individual to sign on my.behalf,to.pull permit,to pay all fees,to obtain certificates.of occupancy's,on all of Lennar Homes- LLC permitting and construction related needs. This letter supersedes all others. Please remove any and all other authorized representatives from any previous letters and please maintain this letter as your only reference for authorized representatives for my license. • Rob Christy • Christopher Smith • Ashlee Callahan • Suncoast Permits • Elissa Holleran • Tad Thaxton • Stephanie Farmer • Elmer Bennett Business Address: 4600 W Cypress Street,Suite: 200,Tampa, FL 33607 Business.Phone: 813-57475743 Business Fax: 813-574-5703 If you have any questions or need to contact me at any time, please reach me at 813-5.74-5740. . Sincerely, Steve.Robert Smith Lennar Tampa Director of Construc ' ,ygtiq oy ; KRISTEN JOSEPH Commission#GG 077910 Expires April 21.2021. . . . ,;�fin;•• gwidedThruTmy Fain lnsurM8003857019 ho is personally known tome, Sworn and subscribed before me this ;:�""•i_••, KRiSTEN JOSEPH _2!�Iay of hAai ifA 2018. Com11won#GG 077910 q•- Expires April 21 2021. :y;;;;;:• Bonded Thru Troy Fain Insurance 800 38rr7019 No Public 4600 West Cypress Street Suite zoo Tampa,FL 33607• Phone:813-574-5700•Fax:813-574-5703 LENNAR.COM Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhilisfl.zendesk.com> Sent: Friday,August 31, 2018 3:33 PM To: Jacqueline Boges Subject: [Request received] 3205 Kresterbrooke lane by#20164 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/237084 ................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Aug 31, 1 2:32 PM MST 3205 kresterbrooke lane by#20164 water sewer This email is a service from City of Zephyrhills Support . 1 PASCO COUNTY, FLORIDA Permit No. �� Date Permitted Builder Name/Owner Name bjLflGc-,� �� Control# County Parcel No. 24 ZFo?-1—Q 1 00-0M00- 220 SubDiv: 06-&er, Address/Location 32 OS , 6ako- L,_�, Zy+! Classification/Type of Use 2 �.� TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: � Exempt [] Yes —] No How Determined 4" f Impact Fee Amount $. 3 632 OV Zone No. TAZ: i t SCHOOL IMPACT FEE A Z6 Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑ No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7( � Exempt ❑ Yes ❑ No How Determined Y LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner.on notice of this assessment and thQ conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3205 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-1220 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20164 Date: 12/18/2018 aadv- L,/ ISSU Y: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE PASCO COUNTY pAs DEVELOPMENT SERVICES 8731 Citizens Drive Date: 11/6I2018 COUNTY FLORIDA New Port Richey, FL 34654 OPEW Svncr•_c.Vr�urnvr Pincrs. 727-847-2411 * NOT A PERMIT ** Receipt#: 1807117 FEE DESCRIPTION .ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1400888 $12.58 $12.58 1807117 11/6/18 Waste Single Family Permit#20164. TOTALS: $12.68 $12.68 Receipt# Paid sv Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1807117 Check 1076140 556 BCCCP05VV 11/06J2018 $12.58 Total Payments: $12.58 pavor Address Phone Lennar Homes,LLC 3205 Kresterbrooke Lane Comments: 24-26-21-0100-00000-1220 While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 11/6/2018 Page 1 of 1