HomeMy WebLinkAbout18-20166 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780--0020 20166 ' BUILDING PERMIT SINGLE FAMILY RESIDENTIAL _ PERMIT.INFORMATION LOCATION INFORMATION Permit#:20166 Issued: 8/30/2018 Address: 3217 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER Amount Paid: 17,790.47 Date Paid: 8/30/2018 Parcel Number: 24-26-21-0100-00000-1230 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL:33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT - APPLICATION FEES BUILDING FEE 1,426.49 E E TRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 1.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � Inspections Required FOOTER 2 D ROUGH PLUMB MISC INSULATIONCEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-3217 Kresterbrooke lane,2,276 sq ft i Column SQ. FEET .PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER IVIETER:j $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,790.47 Jacqueline Boges From: _ City of Zephyrhills Support<support(e_bzephyrhillsfl.zendesk.com> Sent: Friday, August 31, 2018 4:18 PM To: Jacqueline Boges Subject: [Request received] 3217 kresterbrooke lane by#20166 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zei)hyrhillsfl.zendesk.com/hc/requests/237116 ...................................................................................................................................................................................................................................................................................................... .............................................................................. II Jacqueline Boges - -T- Aug 31 , 1 :1 7 PM MST 3217 kresterbrooke lane by#20166 water sewer This email is a service from City of Zephyrhills Support . 1 II II 99 1 II HH®a®aYY I IIIII II�II I�III IIIII I�I�I II6II�I6II II E��IIIII�I��I I9II I�tll 2018147348 Rcpt11986282 ITec: 0.00 DS: 0.00 08/29/2018 C. F. , Dpt,y Clerk ?HULA S.0'NEIL,Ph.D.PASCO CLERK & COMPTROLLER 08OR9BK01m PG 1663 Permit No. Parcel ID No 24-26-21-0100-00000-1230 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 123 Street Address: 3217 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: .i N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND.TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE,OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 13 day of March ,by Steve Robert Smith as Vice President (typr�nbehalfof e:g.,officer, stee,attorney in fact)for Lennar Homes, LLC (name of pa ho ' strument was executed). Personally Known E OR Produced Identification❑ Notary Signature Type of Identification Produced Name(Print) Sa HOIleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. __-4- lr�:� ELISSAM.HOLLERAN -Signature of Na ural Person Signing Above C4=11810n#FF 985837 Ex'Ires June 8,2020 wpdata/bcs/bcs form; e,;?�>�� omrded7hruTroyFolnimmrmeetoll-3W7010 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Perimittin 813 363 2891 1 ' ' . I 1 9 1 1 1 1 1 '= Owner's Name Lennar Homes,UC Owner Phone Number 81 .574,5700 Owner's Address[4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name [N/A Owner Phone Number Fee.Simple Titleholder Address JOB ADDRESS 3217 Kresterbrooke Lane -LOT# 11230 SUBDIVISION Hidden River Phase One A PARCEL ID#J 24-26-21-0100-00000-1230 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADDIALT SIGN DEMOLISH qINSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME O STEEL DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure Fence BUILDING SIZE U/R SF 2276 ! SQ FOOTAGE 1817 HEIGHT 1 StOrY VIBUILDING VALUATION OF TOTAL CONSTRUCTION ELECTRICAL 1$ AMP SERVICE ® PROGRESS ENERGY Q W.R.E.C. PLUMBING 1$ MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS W1 ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do I I I 1 &.44.4-41-4.4 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 BUILDER COMPANY I Lermar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN LY/N Address 4600 W.Cypress-'9t_.­ License# Ste.200,Tampa,FL 33607 CGC1518166 ELECTRICIAN COMPANY I Edmonson Electric, Inc. SIGNATURE REGISTERED FEE CURRENLY/N 034 Skipper Road Tampa, FL 33613 License# I EC13005408 Address 5 PLUMBER (4g7 COMPANY Bayonet Plumbing, Heating &AC, 1nc_ SIGNATURE REGISTERED Y/ N FEE CURREN LILN J P.O. Box 5308, Address FP-, Bayonet, FL 34674-5308 License# [CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 5308, Bayone FL 34674-5308 License# FcAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# 1 CCC057991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans Wl Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY-requir6d for all NEW construction. N v . . . . . . . . . . . . . . . . . . . . . . . . . . . ". . . . . Diteeltio4n . . . . . . . Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: -The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulation's. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or-intended contractorlare uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign ' portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not p ioperly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy' or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to!be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in go od faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or,violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is-considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTIC&M COMMENCEMENT. FLORIDA JURAT(F.S.1117710 I i OWNER OR AGENT CONTRACTOR o(or efore -this Subscribed and sworn t a i Subscribed and sworn to(or affirmed)before me this i -gun-i o by Ashlee Callahan - ia-Jun-ia_ _ _ by- Ashlee-Callahan------- - Who is/are personally known to me or hasihave peed ^ Who is/are personally known to me or tification. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran - Elissa M.Holleran Name of Notary tvoed,printed or stamped Name of Notary typed,printed or stamped ' �1��1441,.N�GIh�lIW' �I,I��,k�lWQt$�IW - -, �nm>l.�ItR�Q�' � wi�+rnrt�mM�lre ��4tt�d�e>t����'p�� ��h�t�dur�d;il7id 6 �+19�aTaayFde9w1�4b11t ,11��TpU , 9�Id1�TYN'r.�lilr9yP4HQEii�✓,111' -- _ - I ing e Family we ing Plan Review Comments -L F.F.E. shall be a rmnirnum of-8" above the road elevation and an.engineered site plan. . - 2. Lots-shall be graded.to.comply with'R401.3 of the F.R.C. 3. Compaction:test required.if 24" or more of fill dirt is brought in.at any one place: 4: 'Tie in survey required before pouring concrete.. 5. Driveways:require a R.O.W.use permit: All-4 sides of driveway thru the sidewalk shall have- expansion material: . 6.. All setbacks shall be met: .7. All.property:markers shall be.uncovered and'marked.at time of first.'inspection: 8: :All A.D.A. requirements shall be met.:'. 9. No.electric;plumbing, mechanical;,or framing shall be covered without an inspection.and approval first. 10. All Garages shall comply.with secton R302:6-ofthe F.B.C: Fire Separation . 11. Appliances shall not:be installed in-A location where subject to.mechanical damage unless. :. protected by approved.barriers: M303.4 of.the F.B:C 12. Water heaters shall comply with section P607, of the F.B-.C: 13. Foundation su orts for A/C.units.shall be raised-at-least 3'.' above finished ade. M 1308.i PP . gr . . . 14. Return air in all,:bedrooms..F.B.C. M1620.4 15:-Smoke detectors'are to b,installed:in accordance:with R313.1-of the F.B.C. 16..All glazing requirements are:16 be'in accordance with R308.4.of the F.B.C. 17. All means of egress are to be in-accordance with R31_Lof the F:B.C. 18. `.`Green gypsum board"shall riot be used as a backer.in:showersor tubs. R702.4.2.F.B.C. 19. Combination-type-AA—'I breakers_are_required.at all locations requiring an AFCI,type breaker: 20. Carbon inonoxicle.alarms:will-be required in new:construction that uses fossil-burning heating or appliances or an attached garage. _They shall be installed in accordance with the F,B.C: 21. All plumbing, mechanical,�and:electrical shall:be separate from unit to:unit: This includes all underground:plumbing and electric. 22. All 2016 N.E.Q. Codes.will be enforced. .23:-Tamper=Resistant Receptacles 1n accordance with 406.11 of the 20l6 N.E:C . 24:.In accordance-with the Land.Development:Code, lots.shall be sodded before final at least 10 . . . feet around the structure.:: 25. Blower door test and blown iri insulation card shall beprovided before C:.O.. . 26 f1-copy ofthe energy caclssltall be with perfnit.at all times., 27.. Copy of finial insulation report shall be yrovided:with per»iit before:final F.F.E.-Finished Floor-Elevation F.B.C- Florida Building Code 6a'Edition. R.O.W.-Right of Way A.D:A.-Americans with.Disabilities Act N.E.C.-.National Electric Code(2011) Lennar Homes-3217 Kresterbrooke Ln.-2,276 sqft Column SO. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $' 139.13 SUB-TOTAL $ 2,067.50 Public Fee 1% TOTAL $ 2,067.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,194.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,795.47 f- t FORM R405-2017. FLORIDA ENERGY.EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0123 Project Name: 1791A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3217 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 57.72 Glass/Floor Area: 0.079 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by 'Review of the plans and :THESx �, this calculation are in compliance with the Florida Energy' specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. { have ><upich Before construction is completed PREPARED BY: '" ►� DATE: this building will be inspected for compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9, 9 P with the Florida Energy Code. OWNER/AGENT: JLJN BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the ai andler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance wi R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 6/13/2018 11:16 AM EnergyGauge@)USA Section R405.4.1 Compliant Software Page 1 of 4 S FORM R405-2017. FLORIDA ENERGY EFFICIENCY CODE.FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0123 Project Name: 1791A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3217 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl, U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 57.72 PASS Glass/Floor Area: 0.079 Total Baseline Loads: 58.15 hereby certify that the plans and specifications covered by Review of the plans and T SSA this calculation are in compliance with th.eflorida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Aul ich Before construction is completed DATE: this building will be inspected for •- compliance with Section 553.908 I herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 6/13/2018 11:16 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE ,FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0123 Project Name: 1791A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3217 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ b.Frame-Wood,Adjacent R=11.0 331.33 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ftZ 6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ftz Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ftZ SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEERA5.00 c. U-Factor: Dbl,U=0.56 23.00 ftZ ' SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 57.72 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are.in compliance with the Florida Energy i specifications covered by this Code. calculation indicates compliance y;� '' = re• { /, with the Florida Energy Code. PREPARED BY' 'Dave Aupic� Before construction is completed DATE: this building will be inspected for µ. compliance with Section 553.908 *" 'b I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. yyV�� ' OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 6/13/2018 11:16 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1791A1 sf ADS'Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 ___ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC ' / I V # Type Ventilation Vent Ratio(1 in) Area. RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood 6/13/2018 11:16 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 r � FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0.23 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Metal Law-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 1453.6 79.8 150.08 .227 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1 6/13/2018 11:16 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 t FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma Jun Jul Au Se Oct Nov Dec Heatin HJan HFeb Mar Apr May Jun Jul Aug Sep Oct Nov HDec Venting Jan Feb X Mar Apr May Jun Jul Aug Sep Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 i PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default$Ibs/s .ft. 0 ftz 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 6/13/2018 11:16 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 28.4 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER e)Other 7.Windows,type and area a)U-factor:(weighted average) 7a. 0.553 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14. Heating system: Capacity 28.2 c)Area 7c. 143.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10B2. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans, a) Under attic 11a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11d. No e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 06/13/18 Address of New Homee,Z3217 Kresterbrooke Lane City/FL Zip: , FL ZeFhyrhills,FL 33540 6/13/2018 11:17:01 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Analysis Job: 1791AI sf ADS Carrier Date: 611312018 Entire House By: Dave Barnet Plumbing Heating and Air Project Information For: Lennar Homes De -ign Conditions s Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 280N Relative humidity 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.6 6529 25.4 Ucts iGlazing 30.2 4772 18.6 wall Ucts Doors 23.5 466 1.8 nfiltmtion Ceilings 1.3 2271 8.8 Floors 3.4 6125 23.9 Infiltration 2.2 2887 11.2 Ducts 2616 10.2 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 Other Ceilings Adjustments 0 Total 25667 100.0 Component Btuh/ft2 Btuh % of,load 'Walls 2.8 3248 14.9 Walls Internal Gains Glazing l48.7 7697 35.3 Doors 18.4 365 1.7 Ceilings 1.7 3140 14.4 Floors 0 0 0 Infiltration 0.5 647 3.0 Ducts Ducts 2982 13.7 Ventilation 0 0 Internal gains 3750 17.2 Glazing Infiltration Blower 0 0 Adjustments 0 Ceilings -Total 21827 100.0 Other Latent Cooling Load= 2875 Btuh Overall U-value=0.104 Btuhlftl-'F Data entries checked. -Fk wrilghtsoftl 2018-Jun-13 11:13:43 Right-Suite®Universal 2018 18.0.16 RSU05714 Page I ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=M,18 Front Door faces: E Job: 1791A1 sf ADS Carrier Project Summary Date: 6/13/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: FBC 2017 Desian Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23051 Btuh Structure 18845 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25667 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21827 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2341 Btuh Ducts 534 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 181g 181g Equipment latent load 2875 Btuh Volume(ft3) 15459, 15459 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 24703 Btuh Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC53OA00300 Cond 25HBC53OA00300 AHRI ref 9154945 Coil FX4DNF031L ' AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24140 Btuh Heating output 28200 Btuh @ 470F Latent cooling 4260 Btuh Temperature rise 26 °F Total cooling 28400 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point= 30°F Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t -�- wrightsoft• 2018-Jun-1311:13:43 w- Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ��` ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 1791A1 sf ADS Carrier Date: 6/1312018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 21827 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2875 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 24703 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Sensible capacity: 24140 Btuh 111% of load Latent capacity: 4260 Btuh 148% of load Total capacity: 28400 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Output capacity: 22528 Btuh 88% of load Capacity balance: 30 °F Supplemental heat required: 3139 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. Wrightsoft- 2018-Jun-13 11:13:43 Right-Suite®Universal 2018 18.0.16 RSU05714 ACC Page 1 ...uipment11791 sf ADS template 2.5ton Carrierrup Calc=MJ8 Front Door faces: E 30 RL k 127 M L A _AP Ff EL 'FF& in F-FF-EL7 A 25/ -0 126 A V6 P kSE I 32- :0 Fr.M AMM 79 As 100 25 FF EL LU OFM rim EL FFRL :0 73.4 101* 1 A24 L. A FF M, k,:, I .34 102 A FF EL V Tul 35 A FF UL 103 M45 1-21 I L rpL-Ai A L---------- 36 1 TO I 't 104 121 L. - ------- A FF EL 37 FF EML MOO 72-W A 12019 A I I 40 47- 38 A 7 IVA FFEL A F-F r M7L 106 A FFEL I N Ff EL V *%, JWEL A I V. 07 118 lo , rim 8 A FF F.L ?Zia/ N A 79 Tef, M \ N r Aj Fr 117 72-25 EL 110 I.W/ A16. A 110, ja W Vp" 15HE Kmjay-Hom SCALE and AMOCWtei, Ift. M51ralm $P V su-HURN AND ASSOCIATES, 04C. DRAWN BY 7EPFYRKiLLS, �LOMQA 33,142 s P -0400 FAX (S13) "782-497E 109RCUM CA MOM695 CLC CiTY O.F .M.PHYRHILLS 73.A --M. Nary 7 eA ' LffA YA ; !4 0/)_A- SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 123 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. }` THIS SURVEY IS SUBJECT TO ANY FACTS THAT N MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6600.00 Q. FT, EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =__18_38 SQ. FT. n UNDERGROUND FOOTER, STEM WALL, AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =_2 0. FT.GARAGE 400 SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR ___ LEGEND: COVERED LANAI = N/A S0. FT. SHOWN. ww- = PROPOSED DRAINAGE FLOW PATIO = 23 SQ. FT. W DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE CONC. DRIVE = 339 SO. FT. _J NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & CONC PAD = 9 Q. FT. 6 PRIVATE SIDEWALK = 72 Q. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES' IMPERVIOUS t PAGE PRELIMINARY INDICATES STAGE AND ISAT IS SUBJECT I- 2719 TO Q. FT. LOT GRADING TYPE = A SOD = 3881 _SQ. FT. CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = FRONT SETBACK = 20' CERTAIN DATA SHOWN HEREON BASED ON OFF LOT AREA CALCULATIONS SIDE SETBACK = 10' ENGINEERING PLANS PROVIDED BY CLIENT. RIGHT OF WAY = 720.00 S0. FT. REAR SETBACK = 10' DRIVE APRON 144 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK =_ 240 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD = 336 _SQ. FT. TO PROPERTY LINE. TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA =_7320.00 SQ. FT. DRIVEWAY = 483__SQ. FT. SIDEWALK = 31 Z_SQ. FT. SOD = 4217 SQ. FT. I LOT 101 PLAT LOT 124 PLAT BOUNDARY BOUNDARY HIDDEN RIVER PHASE ONE A I (PLAT BOOK 74, PAGES 101-121) S 89'36'58" E 110.00' � 9'rJ 250 ' I w :o 0 o: : z ......................... 36.17. i g 30.17' ....................i........ wN 21-1? O z T O Wp- (O LOT 102 w w <W M y5o^:;I,;..•j: �' Qaa` HIDDEN RIVER PHASE ONE A o 1n z=._ o N ,o: R o PLAT BOOK 74, PAGES 101-121 N a-gof o. w o J O = �C, �om O O 59._4. I * Ld Z .........30:1.�.......� 20.50' 0 0• :o o: -AAA1 N 89'36'58" W 1 10.00' -AAA,- LOT 103 I HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) N LOT 122 M .' N m 00 cn 11 co PRM(P) 0 N PROPOSED: `D LOWEST FLOOR ELEVATIONS: m LIVING AREA: 73.20' 1 GARAGE AREA: 72.66' DESCRIPTION: ELEVATIONS REFERENCED TO m LOT 123, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA , OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. a APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9 30 1992 Project Number: Square Feet: 6600.00 f LENNAR HOMES Z LEGEND: - -_ o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONN 0NEF `B/C= BACK 06 CURB, C/S= p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P.=' ED6Z OF P-A-VE`AENT; ESM'T= EASEMENT, = F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND:NAIL P=-;F..OUND PINCHED m PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMA14ENT CONTROL POINT,•:PRM=PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY' BENCHMARK, m U P= UTILITY POLE, W F= WOOD FENCECL - - < JOHN R.BEACH&ASSOCIATES INC. Drawn By: SMS SURVEYORS AND MAPPERS ' hec °c t 911 WEST ST. PETERSBURG DRIVE Checked By: w ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 S1"I30' NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 6/12/18 ACS (Qz o THE ORIGINAL RAISED SEAL OF A FLORIDA SIG URE DATE LICENSED SURVEYOR AND MAPPER N R. BEACH v Revisions: pRIDA REG. LAN SURVEYOR No. 2984 LB 4493 JEFF M. HARTLE. PROFES RVEYOR & MAPPER No.7123 24-26-21-0100-00000-1230 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, August 18, 2018 Parcel ID 24-26-21-0100-00000-1230 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3217 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 See Plat for this Subdivision Taxable Value $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 123 OR 9767 PG 2864 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use +�Description�Zoning ;Units _ Type O cir a Condition Value 1 1 0100 �SFR MPUD-M 006 0_0 SF ;����, __.. _ $4.50 _1 1.00 $27,000 2 0100 SFR MPUD� 600.00 SF $0.90 j 1.00 ' $540 Additional Land Information Acres 0.15 ITax Areal 30ZH Code -- Residential Code HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line _ `;Description r uTT ^Units VValue No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type _ DOR Code Condition Amount. _ 07/2018 9767 / 2864 Warranty Deed_ 05_ Vacant -j Multi-Parcel Sale V 09/2011-� 8606 / 3376 _ Warranty Deed_; 05 f Vacant Multi-Parcel Sale_ 06/2010 j 8360 / 1872 Certificate of Title �� 12 jv Vacant j $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000001230 8/24/2018 PASCO COUNTY, FLORIDA _ Permit No. Data Permitted f6-Z7--ZC9 Builder Name/Owner Name iQYI Control#' County Parcei No. SubDiv: 96 eA Address/Location 5247 k Classiflcatlonlrype of Use it t TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 21 2.7,b Exempt_ ❑"ies ❑ No How Determined Impact Fee Amount Zane No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7,1 ff.'�- yr` (057) Mobile Home (058) . Other Residential 123) Collection Fee Exempt Yes ❑No How Determined i PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT s 7&1 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes' ❑ No How Determined Total Amoun RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION r: . PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. 32 DATE RECEIVED BY RECEIPT NO. DATE BY ` i:' �- 12-3 PASCO COUNTY 7�-D DEVELOPMENT SERVICES PASG 8731 Citizens Drive Date: 11/6/2018 COUNTY FLORIDA New Port Richey,FL 34654 OPEN SiAcrs,OURANT PLACES. 727-847-2411 ** NOT A PERMIT ** Receipt#: 1807120 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1400891 $12.58 $12.58 1807120 11/6/18 Waste Single Family Permit#20166. TOTALS: $12.68 $12.58 Receipt Paid By Check# CC Auth Cashier ID Workstation Receipt Date Amt Paid 1807120 Check 1076141 556 BCCCP05W 11/06/2018 $12.58 Total Payments: $12.$8 Pa or Address Phone Lennar Homes, LLC 3217 Kresterbrooke Lane Comments: 24-26-21-0100=00000-1230 While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or"heck fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 1116/201B Pagel of 1 Jet Stream® Ultra Blowing Wool Insulation N�0 Mc and Cavity Wall Card �� � t I he.h m,ener&t Batts and Blankets Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum''1W internal comigation,a minimum length recommendations,Knauf insulafiort bafEs and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5.35 ibsfminute.Recommended feed provide the full R-value. rate is 15-25lbslminute. R-Value*� Minimum Thickness Thermal Performance(Sidewall and Attic Application) To obtain an The stated thermal resistance(R-value)is provided by Installing in accordance with the manufacturer's instructions.Failure to install the Installed Insulation should required number of bap 1,000 square feet and exceeding the maximum square feat of coverage per bag as recommended by the label Insulation resistance not be less than: (R-value)of will result in lower installed R-values.Field blending of this product with other loose fig insulations is not recommended by the manufacturer. R-49 13.75' Cavity Wall Bag Net Weight-Nominal 32 tbs.,Minimum 31 tbs. R-38HD 10.25' R-38 12.04" R-Value* Bags per 1000 SF Maximum Net Minimum R-30HD 6.25" To obtain an The number of bags Coverage per Bag Weight per 5F Insulation per 1,000 square feet Contents of this The weight per square R-30 10.00, Cavity resistance of net area should not bag should not. feet of installed insulation R-26 9 40° Framing Depth of: Density be less than: rxvertaare than: should not be foss than: R-22 6.50' 2°x 4' 3.50' R-15 1.8 lbs./cu.ft. 16A bags 61.0 sq.ft. 0.525 tbs. R-21HD 5.50' 2°x 6' 5.50° R-23 1.8 IbsJcu.ft. 25.8 bags 38,8 sq.ft 0.825 lbs. ? R-19 6.25" 2"x 8' 7.25' R-31 1.8 IbsJcu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. R-15HD 3.50' } RA3 3.50' 2°x 10" 9,25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 tbs. R-11 3.50' R means resistance to heat flow.The higher the R-value,the greater the insulating pmw..To get the marked R•value,It is essential that this insulallon be installed properly. R-8 2,50° "R-18 h a 5.5°cavity.Conforms maSTnf c 665 and merit Open Attic Application Bag Net Weight-Nominal 32 tbs.,Minimum 31 lbs. Spee tcaflon HH4521F. Minlmiii& I Framing Adjustment Bags/ Maximum Minimum Initial Settled i 9 1 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this 1,000 sq.ft of area to be Insulated should be as shown below. R-Value* 1,000 SF of not area bag should not of installed Installed insulation bag should Ba SlMSF Ba s/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more 9 9 resistance(R Value)of: than: mom than: be less than than. than. Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF 952 tbs. 19.750° 19.750" R-Value Dimensions Framing Framing R 49 23.5 42.5 SF 753 lbs. 15.375° 16.375" 2x4 29.2 29.4 R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670lbs. 14.875" 14.875" 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000' 2x4 23.0 23.2 R-30 13.6 73.3 SF A37 Ibs. 10.375" 10.375' R49 2x6 2V 22.9 R-26 11.8 85.0 SF .377 tbs. 9.125' 9.125' 2x8 22A 22.7 2x4 20.4 20.6 R 22 9.8 102.2 SF 313 ibs. 7.750° 7.750° R-44. 2x6 20.1 20.3 R-19 BA 119.3 SF .268 tbs. 6,750' 6.750° 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 tbs. 4.750° 4.750' 2x4 17.3 17A R-11 4.7 210.8 SF .152lbs. 4.000' 4.000° R-3B 2x6 17.0 17.2 Bag Netweyht-A'mima132ibs-i0unsanalft. 2x8 16.7 17.0 Conerage Wkwala5m daareseddermnedusing aVde•testa'hbViang nnaftW;n9mdgearvit l3•gaieOWkG'to psi it Penn 15Vd T6nemaytffiu Wb9se. l cedosms to dre pertomtaae rewemana dASW C M,Type 1,andomledr-eftal Spedruation W4.16303,Type6pass B.R-Yades ae Me-*W inacwrdma wn C 667 and C 516. 2x4 13.2 13 ids Rods .3 •`tt'means resbtanceta dregmwtneinw�pomlagetntmateditr ,lisessen6etitrat gets nulgm WnstWpvpedy.gym cbe}roarsett.getNsvvo- R-30 2x6 12.9 13.1 � 0xmsmcaefdy.Insbubonsdorolamewehhspackage •'arced a�TA'°d iaM2Ywrusn 3 c2dY C,epredrsed aet9mimi are/a 2a}rarperiod+ratf�t Pe<�:ortess.TNsaawunt dse55rg h 3a'nraTfesgrv�d.TGemSam.Peinsia:mi and seWtM 2x8 12.6 12.9 tdeeeeaamenae> rdeeema 2x4 11.3 11.4 vouttzg tsaregsteredratzmazta R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 20 9.3 9.5 R-Value Thickness R-22 2x6 9.1 9.3 AfficArea R- at Inches 2x8 8.8 9.1 Sloped Ceilings R- at Inches 2x4 7.9 8.1 Walls R- at Inches R-19 2x6 7.7 7.9 Floors(over an unheated crawl space) R- at Inches 2x8 7A 7.7 2x4 5.3 SA Crawl Space Perime er R- at Inches R-13 2x5 5.0 5.2 Date Installed If - V.- 2x8 4.8 5.0 Blo s ation has been igs Iled in conformance with the above rec s vide an R-value of: 2x4 4.3 4.4 R_ using �i bags of this insulation to cover, a square feet of area R-11 2x6 4.1 4.3 at a minimum thickness of inches. 2x8 3.8 411 f x 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3217 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W. CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-1230 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 20166 Dat 12/26/2018 ISSUED B • BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE DABuilding and Const-mction.Services(BCS) JL I A- !SC COUNTY FLORIDA IV- i Blower Door Test Report Form Property Address: Unit Permit#: Testing Company Name* -2.01 Q4(10 Test Date. Tester Name: Teste Cert M Contact Phone: Email: J 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).As required by the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled penetrations of the building thermal envelope. During testing:(check to verify condition met) UdExterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather-stripping or other Ef Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration Interior doors,if installed at the time of the test,shall be open Id Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed 9 Heating and cooling systems,if installed at the time of the test,shall be turned off IdSupply and return registers,if installed at the time of the test,shall be fully open Vb Building volume(ft3) Q5o Airflow at 50 Pascal(CFM) ACHso Air changes per hour at 50 Pascal Q5o x 60—.* Vb = 5-s ACH5o (10 ACH minimum) Pass 16' Fail E-1 r7 Outside Air mechanically introduced to space(less than 3.0 ACH) I hereby certify that the above envelope leakage per, results demonstrate compliance with Florida Energy Code requirements in accordance With Section R402.4.1.2. ;L0 Signa 0 ester Date