HomeMy WebLinkAbout18-20168 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20168
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20168 Issued: 8/30/2018 Address: 3244 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER
Amount Paid: 17,790.47 Date Paid: 8/31/2018 Parcel Number: 24-26-21-0100-00000-0870
CONTRACTOR INFORMATION' OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS STE STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT
APPLICATION FEES
BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75
MOBILE HOME ELECTRICAL 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
2,
In' ections Required
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
Ch PA I I L
W
RS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
PASCO COUNTY
DA DEVELOPMENT Citizens Dve SEkVICES
JI-11 ISC 8731 Date: 11/6/2018
COUNTY FLORIDA. New Port.zlhisq,FL 34654
OPIN SRAMS.IIM16LVTPIALM% 727-847-24 11
NOT A PERMIT
Receipt M 1806886
FEE DESCRIPTION ACCOUNT CODE UNITS INVOI CE# F.EE AMOUNT PAID RECEIPT# DATE
impact Fee Residential Solid 2450100-:329010 -1.00 1400612 $12.68 $12.56- 1806866 1 1/6h 8
'Waste Single Family
P6ftlt#201611
TOTALS: $12.58 $12.58
Receipt# Paid By Check# CC Auth# Cashier ID Workstation, Receipt Date 'Arrit Paid.
1806686 ibho& 1076134 556 BCCCP05W 11/Q6/2018 $12.58
Total Payments: $12.58
Pa or Address Phone
nnar-Homes, LLC 3244 Kresterbrooke Lane
Comments:
24-26L21-01 bO-00000-6810 -7 A
L/V
While you Will be paying your blllAilih Pesco County Development Services;the full amau.ntofthe craclitcarcl ore-check fees,NOT shown above,Is collected by
First Billing payment services.
MyR�pports/regorts//PASCOPROD/PASC0/ReciBiptPOS—V6.rpt 11/6/2618 page-1 of 1
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Friday,August 31, 2018 4:12 PM
To: Jacqueline Boges
Subject: [Request received]3244 Kresterbrooke lane bp#20168
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/237111
............ ................ ............ ............... ............. ............. ..................
Jacqueline Boges
Aug 31, 1 :11 PM MST
3244 kresterbrooke lane bp#201 68 water sewer
This email is a service from City of Zephyrhills Support
r_ J
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 179161 sf ADS Carrier Builder Name: Lennar Homes 0087
Street: 3244 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction:
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079
Total Proposed Modified Loads: 57.78 PASS
Total Baseline Loads: 58.15
hereby certify that the plans and specifications covered by Review of the plans and Tk1E STD?
this calculation are in compliance with the Florida Energy specifications covered b this a
P 9Y P Y
Code. calculation indicates compliance
with the Florida Energy Code. rtrrr '?� y .°;;•� „ 0
PREPARED BY: Dave Aupich Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
hereby certify that this building,as designed, is in compliance 1.Florida Statutes. .t
with the Florida Energy Code. C'O �
OWNER/AGENT: LDA
DING OFFICIAL
DATE: E:
- Compliance requires certification by tw4R.403.3.2.1.
andler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
7/25/2018 8:25 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE:FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791131 sf ADS Carder Builder Name: Lennar Homes 0087
Street: 3244 Kresterbrooke Lane Permit office: City of ZephyrhiEs
City,State,Zip: FL, Permit Number
Owner Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a-Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=1 1.0 331.33 ft2
3. Number of units,if multiple family I c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1817.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft;t
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor. Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtuthr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 57.78
Glass/Floor Area: 0.079 Total Baseline Loads: 58.15 PASS
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance Zr Z
with the Florida Energy Code.
PREPARED BY: Dave AWich Before construction is completed
DATE: this building will be inspected f :a. .....
or compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory�ealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSIIRESNET/ICC 380,is not greater than 0.030 Qn for whole house.
7/25/2018 8:25 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0087
Project Name: 1791 B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3244 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes .jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079
Total Proposed Modified Loads: 57.78 PASS
Total Baseline Loads: 58.15
I hereby certify that the plans and specifications covered by Review of the plans and • _HE S ,gT
Q
this calculation are in compliance with the Florida Energy specifications covered by this _ p
Code. calculation indicates compliance
with the Florida Energy Code.
Dave AGa p cGc
PREPARED BY: Before construction is completed
DATE: this building will be inspected for .��i - .
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes. .5
with the Florida Energy Code. •�� y �'OXj` ..
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE: Y.
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
7/25/2018 8:25 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4
1
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 1791131 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1817 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume -
1 Blockl 1817 14536
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 ___ 0.3 0 0.7
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1817 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood
7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0
_ 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0
3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0.23 0.01 0
4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0
5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0
6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height . Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in 4 ft 2 in Drapes/blinds None
2 E=>SE 4 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 It 0 in 0 ft 10 in Drapes/blinds None
3 S=>SW 5 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None
5 W=>NW 6 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 427 ft2 427 ft2 42 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000305 1453.6 79.8 150.08 .227 6
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1
7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow _SHR Block Ducts
1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar [ ]Apr May X Jun Jul rj Aug �Xj Se Oct N Nov Dec
Heatin HJan Pq Feb Mar [ ]Apr l May l Jun Jul [ ]Au Sep Oct Nov Dec
Ventin Jan Feb Mar [X]A r [ Ma [ Jun Jul [ ]Au Se [x]Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 Main
Name: Signature:
Rating Compant: Date:
7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
e
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13.Cooling system: Capacity 28.4
a)Split system SEER 15.0
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.553
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14.Heating system: Capacity 28.2
c)Area 7c. 143.3 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 8.50
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised (R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a)Electric resistance EF 0.95
b) Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 11.0
2. Masonry(Insulation R-value) 1062.
16.HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls Ile. d)Multizone cooling credit
d)Radiant barrier installed 11 d. No e)Multizone heating credit
f)Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed (or exceeded)in this home before final inspection. Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: 07/25/18
Address of New Ho : 3244 Kresterbrooke Lane City/FL Zip: FLZephyrhiHs,FL 33540
7/25/2018 8:26:24 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
BuildingAnalysis Job: 1791B1sf ADS Carrier
Y Date: 7/24/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information.
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(OF) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Heating
Component Btuh/ft2 Btuh % of load
Walls 5.6 6433 24.7 acts
Glazing 30.2 5288 20.3 Wall
Doors 23.5 466 1.8 Infiltration
Ceilings 1.3 2271 8.7
Floors 3.4 6125 23.5
Infiltration 2.2 2887 11.1
Ducts 2616 10.0
Piping 0 0 Glazing Floors
Humidification 0 0
Ventilation 0 0 Other Ceilings
Adjustments 0
Total 26087 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 3200 14.3 Walls Internal Gains
Glazing 47.6 8332 37.2
Doors 18.4 365 1.6
Ceilings 1.7 3140 14.0
Floors 0 0 0
Infiltration 0.5 647 2.9 Ducts
Ducts 2982 13.3
Ventilation 0 0
Internal gains 3750 16.7 Glazing Infiltration
Blower 0 0
Adjustments 0 ceilings
Total 22415 100.0 Other
Latent Cooling Load= 2875 Btuh
Overall U-value= 0.106 Btuh/ft2-°F
Data entries checked.
w.-ightsc ft- 2018-Jul-25 08:44:09
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces: W
1
Project Summary Job: 1791B1 sf ADS Carrier
J •y Date: 7/24/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Notes: FBC 2017
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23471 Btuh Structure 19433 Btuh
Ducts 2616 Btuh Ducts 2982 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 26087 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 22415 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2341 Btuh
Ducts 534 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ft2) 1817 1817 Equipment latent load 2875 Btuh
Volume(ft') 15459 15459
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 25290 Btuh
Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC53OA00300 Cond 25HBC53OA00300
AHRI ref 9154945 Coil FX4DNF031L
AHRI ref 9154945
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24140 Btuh
Heating output 28200 Btuh @ 47°F Latent cooling 4260 Btuh
Temperature rise 26 OF Total cooling 28400 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.038 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 31 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- - wrightsoft® 2018-Jul-25 08:44:09
^-^•� • ��••w� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..uipment11791 sf ADS template 2.5ton Carienrup Calc=MJ8 Front Door faces: W
Manual S Compliance Report Job: 1791B1 sf ADS Carrier
Date: 7/2412018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 22415 Btuh Entering coil DB: 75.7°F
Outdoor design WB: 77.3°F Latent gain: 2875 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 25290 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Sensible capacity: 24140 Btuh 108% of load
Latent capacity: 4260 Btuh 148% of load
Total capacity: 28400 Btuh 112% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 26087 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Output capacity: 22528 Btuh 86% of load Capacity balance: 31 OF
Supplemental heat required: 3559 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1000 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 OF
Meets all requirements of ACCA Manual S.
wrightsoft- 2018-Jul-25 08:44:09
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
14CCk ...uipment%1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces: W
V �1�
ILO 11111H
....,...uw.;r W
r
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: (1�;�
Date Received:
Site: 3 -, t`r 14,,o-4"ra k, W
Permit Type: �G 4�� f ` 7iZ7�0
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
_-e--e
This comment sheet shall be kept with the permit and/or plans.
Kalvin Switzr—Plans Examiner Date Contr ctor and/or Homeowner
(Required when comments are present)
i uiiii lull iiui lull iiui lull lull uii�iiii��ui�0ii�ii�i -_
2018147346
Rept:1986282 Rec: 10.00
DS: 0.00 IT: 0.00
08/29/2018 C. F. , Dpty Clerk
2RULR S.O'NEIL,Ph.D.PRSCO CLERK & COMPTROLLER
08 OR 13K 197 m PG 166 L
Permit No. Parcel ID No 24-26-21-0100-00000-0870
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 87
Street Address: 3244 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(If other than owner)
Address City State
4: Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. Surety: ! N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
�
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 13 day of March ,by
Steve Robert Smith as Vice President (type of a er,trustee,attorney in fact)for
Lennar Homes LLC (name of pa on beha w instrument was executed).
Personally Known N OR Produced Identification❑ Notary ' nature
Type of Identification Produced Name(Print) Elissa Holleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief. — j
; ?i ;;ELISSAM..HOLLERAN Signature of Natural Person Signing Above
Wm.
r C MMI1810n aM FF 88583T
`, EXP83 June 8,2028
wpdata/bcs/bcsform: Dcnde0ruTroyFolnfmunnee1QHQa .7D1D
PASCO COUNTY, FLORIDA
Permit No. -Zd
Date Permitted 9-4Z--M--
Builder Name/Owner Name kAACZ, -901,, - Control#'
County Parcel No. SubDIv: t tzAdE&i
r;
Address/Location 3 2 q' C ve ��tlbl
` Classification/Type of Use Yt L
l TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2, Z J
'E Exempt []Yes ❑ No How Determined
S
Impact Fee Amount $- y'r b 3 Zane Na. TAZ:
y SCHOOL IMPACT FEE
Account (056) Single-Family petached House Amount $
(057) Mobile Home �—
(058) Other Residential
123) Collection Fee
Exempt H Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
is Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
1.`
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑ No How Determined Total Ampynt,��
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
c
DATE RECEIVED BY
r
RECEIPT NO. DATE BY
Lennar Homes-3244 Kresterbrooke lane,2,276 sq ft
Column Its
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,426.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,062.50
TOTAL $ 2,062.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER:1 $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,189.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,790.47
24-26'2l-0l0O-OOOOO-O87O|Pasco County Property Appraiser Page lofl
. ^
Data Current as Of: Weekly Archive - Saturday, August 18, 2018
Parcel ID 24-26-21-0100-00000-0870 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
Physical Address Extra Features $0
KRESTERBROOKE LANE
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540
See Plat for this
Subdivision Taxable Value $27,540
HIDDEN RIVER PHASE ONE B
LOT 87
OR 9767 PG 2864
Jurisdiction �
City of Zephyrhills
Land Detail (Card: 001 of 001)
Additional Land Information
FEMA
Code
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
lCondition Amount
07/2018 9767 / 2864 Warranty D_eed 05 Vacant Multi-Parcel Sale
bttp .aupx7yuzoel=2l2624OlO000OOOU07O 8/33/2010
Lennar Homes-3244 Kresterbrooke Ln:2,276 sgft
o umn ts
SO. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,431.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,067.50
Public Fee 1%
TOTAL $ 2,067.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER:j $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,194.63
PARK IMPACT FEES $ 769.56
i
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,795.47
'Sin g e Family Dwellin
g
Plan Review Comments:
1:' F.F.E. shall be a niinimum.of.8" above.the road.elevation and an engineered site plan.
2. Lots shall be'graded.to comply with-R40L3 of the F.R.C. .
3.. -Compaction:test required.if 24" or more of fill dirt is.brought in:at any one place. .
4'.. :Tie in survey required before pouring concrete.
5. Driveways:require a R:O.W.use permit. All 4:sides of driveway thru the sidewalk shall have
exp n ansio material:
-6. All setbacks shall,be met.:.
.7.. Ali.property:markers shall be uncovered and marked at time of first inspection:
8. .All A.D.A.requirements shall be met.
9. No.electric;plumbing,mechanical, or framing shall be covered without an inspection and
:approval first.
10. All Garages shall:comply with section R302:6 of the_F.B.C.: (Fire Separation)..
I L'Appliances:shall not-be installed in a location where subjectto mechanical'da.ni e unless.
protected by approved-barriers. M303.4 of'the RB.0
12. Water heaters shall comply.with sectionT607.3 of the F.R.C.-
hall
13. Foundation supports`for A/C.units s be raised at least 3" above finished grade.. M1308.1.
M. Return air in all bedrooms. F:B.C. .M1620.4. - -
15.' Smoke detectors are to be installeddn' accordance with.R313.1'of the:F.B.C.
16: All glazing requirements are.to be in accordance with R308.4-'6f the.F.B.C. .
.17. All means,of egress are to be in:accordance with R311 of the F:B.C.
18. "Green gypsum board"shall not be used:as.a hacker showers or tubs. R702:4:2.F.B.C.
19. Combination-type AFCI breakers are required:at all.locations requiring an AFCLtype breaker:
- 20.' Carbon moiioxido alarms will be required in.new construction that uses;fossil-burning heating
:or appliances or'-an attached garage: They shall be.installed in accordance with.the
21. All plumbing,mechanical :and:electrical shall be s eparate from unit to:unit. This includes all. .
underground plumbing and electric:
22.. All 2016.N.E.-C. Codes:will.be enforced-..
23.Tamper-' Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24.:In accordance.With the Land:Development.Code; lots.shall be sodded before final at leash 10.:.
feet around:the structure.
25. Blower door'test and blown in insulation card shall be provided before C:O:
. 26.A copy of the energy cacls.shall be with permit.at all tinier .
2Z Copy of rival insWalibn report shall be:provided Wi&perirtit before finab .
F.F.E.-Finished-Floor Elevation
F.B.C=Florida Building Code 6 h Edition
R.O.W.-Right of Way
A.P.A.-Americans with Disabilities Act N.E.C.-National Electric Code-(2011)
_
813.780-002u City of ZephvrhiUs Permit Application �_ Fa»813-700-002
Building Department .
Date Received e Contact for Permitting 813 363 2891
Phon
nuxxomon �
7
��ne phoneNvmh�
Owner's Name "wnv
v
Owner's Address 4600 ress FL 33607 Owner Phone Number
Fee Simple Titleholder wome Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS
000Doma/om Hidden River Phase OnepxmcEL/u# 24-26-21-0100-00000-0870
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED wexcuNSTn xoow`cT F--1 8|am F--i DEMOLISH INSTALL R
REPAIR �
PROPOSED USE SFn �—1 COMM F--� OTHER
TYPE opCONSTRUCTION ouocK F—1 FRAME �--� �Ts�c
l/Screen Enclosure Fence
osSCFopnONOpVUoRKidence I i
BUILDING SIZE
mOrOOT7xas�^�// \ nE|o*T �
j(IBUILDING VALUATION OF TOTAL CONSTRUCTION
MECHANICAL VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS �:]' __FLOOD ZONE AREA EIYES Do
su|LDsm COMPANY Lermar Homes,LLC
SIGNATURE
}� u [_Y/ N rssoonnsx
Auumes Ucense#
sLEoTn|cmm COMPANY Edmonson Electric, Inc.
SIGNATURE pssuunnex
4mumss Liuonae#
p�u�osmC Bayonet Plumbing, Heating &AC, Inc
euoN/�um� ��
���� p��n� ��_J
m1umas License#
�soHAm|
CAL COMPANY
SIGNATURE F
--_-__-
uuumss
OTHER COMPANY
�
o|om/TunE
Address Licenua#
o n x n nn w n n n n m u u m o n u m_nn m n k u m n x u u n n m!
RESIDENTIAL Attach(2)Plot Plans;(2).oetsm Building Plans;(1)set m[Energy Forms;R-o+w Permit for new construction,
Minimum ten(10)working days after submittal,date. Required onsite,Construction Plans,Stormwater Plans w/,.Slft Fence Installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisionsAarge projects
�
COMMERCIAL Aopuh;gcomp|�eoomufBun Li
fe 4w
yFonna�R'OPonn/t�rnmwuonstmction.
minimum ten(10)working days after submittal date. Required uno|te.Construction Plans,Smnnvater Plans w/Silt Fence inata/md!
Sanitary Facilities&1dumpatec Site Work Permit for all new projects.All commercial requirements must meet compliunoe
SIGN PERMIT Attach(2)sets vf Engineered Plans. ' �
^^~PnopEnr/SURVEY required for all NEW construction.
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500)
� Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
-
OVER THE COUNTER PERMITTING (copy vf contract required) �
Ramofsifshingles oavem Service Upgrades */C Fenxox(P|uUSumey/Fomoge)
Driveways-Not over Counter|fun public mauwoya'no,dmROW
/ -
i
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions. i
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco ICounty Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact-Fees-and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees-must be paid prior to permit issuance. Furthermore,_if Pasco County Water/Sewer Impact
fees.are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify-that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take toi be in compliance. Such agencies include but are not limited to:
Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks. I
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W"'unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted 'at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood 'Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
I
WARNING TO OWNER: . YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FQR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT ab CONTRACTOR
Subscribed and sworn (or a r d before me this Subscribed and swbfr to(or affirmed)before me this
1.3-Jun-i o by Ashlee Call an 13-Jun-18 by Ashlee Callahan
Who is/are personally known to me or Who is/are personally known to me or
as identification. as identification.
I
Notary Public Notary Public
Commission No. FF98537 on N 98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
E
- � � _� �11��4,�leNfpt��lAW.
I
I,,
IE�4whN,r�d',�(1�9 6tadMI1�1N'rtl��il4lGPlflR4ila#47
Lennar Homes-3244 Kresterbrooke lane, 2,276 sq ft
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,426.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,062.50
TOTAL $ 2,062.50 ,
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
C
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL 6,189.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: 17,790.47
-- FFgL
26
A
E FF !. 7k 17+3.it3
Z
.' '2 i ?4.1
Fr-EL
a
.ems 28 �.
E I
138
125
DWI'
EL
AU
WE
ui
2781
1 2 ., EL
no
,
FM
120. 7 82
40
EL
Mao
FF�l. 314
A '
. - �---9--..
Ff
17
146
FFM-
ff El
-��, ._
�� �• : t A
OWNS
now
WE 147 -
DATE
06/20/06
HIDDEN
HILLS S FLORIDA.- 049-767000
t
yx
' SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 87 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
1� MAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6600.00 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1838 SQ. FT. �� UNDERGROUND FOOTER, STEM WALL, AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =_42 _SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
GARAGE =_406`SQ. FT. SHOWN.
LEGEND: COVERED LANAI =_ N A SO. FT,
rmn.—= PROPOSED DRAINAGE FLOW PATIO =-_23 SQ. FT. w DO NOT SCALE THIS PRINT. DIMENSIONS AND
(00.00) = PROPOSED GRADE CONC. DRIVE = 3_3_9 SQ. FT. ¢ NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE A/C & CONC PAD = 9 SO. FT.
PRIVATE SIDEWALK = 72 Q. FT.
DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS =_41 9 PAGE INDICATES THAT PLAT IS IN
NOTES: = -2719 SQ FT PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = A PROPOSED PAD ELEVATION SOD =-
38- 81_SQ. FT. CHANGE AND/OR REVISION.
=
FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
U
SIDE SETBACK = 10' RIGHT OF WAY = 720. SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 10' DRIVE APRON = 144_SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK = 240,SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
SOD =_ 33_6_-$q• FT. TO PROPERTY LINE.
TOTALS * = 10' DRAINAGE/UTILITY EASEMENT
AREA = 7320.00 SQ. FT.
DRIVEWAY =_483 SQ. FT.
SIDEWALK = 312 SQ. FT_
SOD = 4217 _SQ. FT.
PLAT
BOUNDARY
LOT 88 PLAT
BOUNDARY
�I
2 . o' ~;;. � S 89'36'58" E 1 10.00'
L LJ :.
Z o:
o:
36.17'...
o;
0 .......... .........
w� O ��•.1.7 30.17 00
z 0 O
w^ o O
Y¢w3 ^w .I'^ 'I:^ :'o. w w n LOT 324
Ox co '.. . �' cn mom o
o a .: a S on' w i HIDDEN RIVER PHASE ONE.A
N 1:``:
On, o o a-�¢J O N (PLAT BOOK 74, PAGES 101-121)
n�//wn� 0 ........ 0' -J J
Iy�,�" r 7 2D.50' a_ w O
MM
WZmLd O N
f
�og O I 59._4" ¢ 00
V
w=°y Z ........ ........ 30.17'
�/•► o
/ o:
6:
N 89`36'58" W 110.00
�r�2
Y aJ sJJ.
N
U
w LOT 86
N
(V
N
Co
o �'—PRM(P)
PROPOSED:
LOWEST FLOOR ELEVATIONS:
3 LIVING AREA: 73.60'
DESCRIPTION: GARAGE AREA: 73.06'
ELEVATIONS REFERENCED TO
m LOT 87, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B NATIONAL GEODETIC VERTICAL
o AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA
W OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
a
a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9 30 1992
Project Number: Square Feet: 6600.00 t LENNAR HOMES
Z LEGEND:
oW (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
2 F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
m' PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
ti
m REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
t U P= UTILITY POLE, W F= WOOD FENCE
CL
JOHN R.BEACH&ASSOCIATES INC. Drawn By:
SMS
SURVEYORS AND MAPPERS hec
911 WEST ST. PETERSBURG DRIVE Checked By:
v ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
x 1"=30'
NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 6/21/18 ACS Ora
o THE ORIGINAL RAISED SEAL OF A FLORIDA NA E DATE
LICENSED SURVEYOR AND MAPPER JOHN R. CH
Revisions: FLORIDA REG. LAND SURVEYOR No. 2984 LB 4493
JEFF M. HA EY
ii AL SURVEYOR_& MAPPER No.7123
t
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY i
i
Address: 3244 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W. CYPRESS STE STE 200
Subdiv: HIDDEN RIVER TAMPA FL 33607-4099
Parcel: 24-26-21-0100-00000-0870 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 20168
Date: 2/14/2018
07�tc-&�/
ISSUED BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE