Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-20175
CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 20175 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:20175 Issued: 8/28/2018 Address: 6823 OAKCREST WAY Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s):7 Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 20,000.00 Total Fees: 277.50 Subdivision: OAK CREST ESTATES Amount Paid: 277.50 Date Paid: 8/28/2018 Parcel Number: 02-26--21-0250-00000-007 CONTRACTOR INFORMATION OWNER INFORMATION Name: SET UP MY SOLAR Name: MILLER CHARLES D &TAYLOR CYNTHIA Addr: 4845 ALLEN RD Address: 6823 OAK CREST WAY ZEPHYRHILLS FL 33541 ZEPHYRHILLS, FL. 33542 Phone: (844)340-6996 Lic: Phone: 813-714-5818 Work Desc: INSTALL SOLAR SYSTEM ROOF TOP MOUNT APPLICATION FEES ELECTRICAL FEE 210.00 BUILDING FEE 67.50 INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL TIY� REINSPECTION FEES:(c)With respect to Reinspection fees i I comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. j CONTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received (/ / Phone Contact for Permitting :Number Owner's Name �1Lf/lY Owner Phon 'I f Owner's Address (� V v Owner Phone Number p Ol -T�'f f7 W0 L Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS t�/ Vv 7r- ��' LOT# M SUBDIVISION L VIT- PARCELID# — (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR' ADDIALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE hZN SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK i ') ."U lFii/1 BUILDING SIZE SQ FOOTAGE HEIGHT BUILDING $ „rt1 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER CO) FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO /`, l BUILDER i Q ` / �l OMPANY 3C LOB ( iZ Chi (ryI SIGNATURE REGISTERED CYJJ N FEE CURREN I Y/N l' Address G License# ELECTRICIAN OMPAN REGISTERED N cu Y/N SIGNATURE t(/ � Address License# ,oo l y- � PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN L11 N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. WC upgrades over$7500) •• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS'AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation understate law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-071 as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiv-ing a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,600.00 or more,I certify` that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to delive'r it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify`,that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating i the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An.extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and swom to(or affirmed)before me this S c' d by �rgsworq to Z rm before m h(N� Who is/are personally known to me or hasthave produced giIyar¢.pers��onatffyy MUM .m-e has/have have produced p y as identification. T-Lr 0 -� lG��-�S'�as identification. Notary Public Notary Public Commission No. Com isslo N J P.QUELINE BGGES ;.; Commission#FF 150422 Name of Notary typed,printed or stamped Name of Nota tppe o ecem er s+•. *r ' Pr+ � 0i9 Bonded Thru Troy Fein Insurance BOB-3B5-7 I I[ill[14[ll�[�II Iliill[III NIII Iliil i11�i 1[II[Illil 111111[I 2018145995 r Permit No. o2yf}/75— Parcel ID No co-- � Qz] qxt m~ o NOTICE OF COMMENCEMENT OOo((A p State of i 4 County of ,hCO CD THE UNDERSIGNED hereby.gives notice that improvement vAll be made-to certain real property,and In accordance with Chapter 713,Florlda Statutes, j O the.following information Is provided In this Notice of Commencemn .e G CD CD 1. Description of Property: Parcel Identification No. r 1Cµj co r� f9 Street Address: x tT 2. General DDe�scriOt ort of'lmprovement }r CfW 3. Owner Information or Lessee informaJtt on if the Lessee contracted for the improvement: 'CD Nam Address /' City State t9 Interest In Pioperty: Name of Fee Simple Titleholder: 7 (if different from Owner listed above) x Address ' C State 4. Contractor. - I AAG Address 7 �J City isle W e Contractors Telephone No.:'2t-1f,'4 , 4 Q' S. Surety: �t3 Name CD 4' r�N tr Address City State W� Amount of Bond: $ Telephone No.: �+ 8. Lender. Name (�N � p a Address City State Lenders Telephone No.: 7, Persons within the•-State of Ffodda designated by the owner upon wham notices or other documents may be served as provided by m Section 713.13(1)(a)(7),Florida Statutes: �0 �f�-q a• Name dVtS,t � Address City State c Telephone Number of Designated Person: r- fn 8. In addition to himself,the owner designates of.� ;a to receive a copy of the Lienars Notice as provided in Section 713.13(1Xbf,Florida Statutes, Telephone Number of Person or Entity Designated by Owner; 9. Expiration data of Notice of Commencement(the expiration dale may not be before the completion of construction and final payment to the contractor,,but wig be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS.MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS-.UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE,THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and th%the fasts stated therein are true to the best of my knowledge and babel. �� STATE OF FLORIDA �`� COUNTY OF PASCO Signature of Owner or Lessee, Owners or Lessee's Authorized Officer/Dlrector/Partn or/Manager_ 1 SlgnalorysTille/Office '(1l �y 'f The foregoing instrument was'acknowtedged before m r wa this day of c 20.lO by .' %cs. 0 V es n (type of su ority,e.g.,officer,trustee,- homey in fact)for (name of party on behalf of whom instrument was.executed). Personally Known[]OR Prod d Identification Notary Signature' Type of Identification Produced I 0005<Name(Pe.nt) ;Ne"Puaiia State of Ftw4a F 'f-fiCB A Heli�E. My(;o,ttrtti911ian 22 x3zasr. I�t;pifia G814C312i C22 wpdatalocs/noticecommenaem enf_pc053048 o M 111 IUH City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: (0'r- Date Received: Site: 23 ©Q W Permit Type: A Approved w/no comments: Approved w/the below comments: l7 Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Ilei� Kalvin Switzer s Examiner Date Contractor and/or Homeowner (Required when comments are present) sammys o arr 6.6KW Photovoltaic Solar Array Project Charles Miller& Cynthia Taylor 6823 Oakcrest Way Zephyrhilb,FL 33542 813-714-5818/813-714-2092 6823 •. IV Y S Install New 6.6KW Photovoltaic Solar Electric 22 Panels- Heliene—60M30OW SMA SB-7.7-1 SP-US-40 Ironridge Roof Mount Rail System 22 Panel Placement ALL WORK SHALL CODES FLORIDA BUILDING CODE, Area Panels Roof Mounted (Flus NAL ELECTRIC CODE -H PREVAILING TIO COMPLY W17 2D THE ORDINANCES OF ZEPHYQLLS DINANcES z 0& PHOTOVOLTAIC SYSTEM APPROVAL CERTIFICATE AWARDED TO: CERTIFICATION#: DJ-17-02907 FSEC 1 A CEDGreentech DESIGNATION: SMAS3Zr Inverter-Hyundai HiS-S29OROModules 1 \� 2460 12th St SYSTEM SIZE: 8,990 Wdc Sarasota,FL 34237 DATE: 2017-10-23 http://cedgreentechfi.com/ EXPIRATION: 2022-10-23 Module Manufactuer Module Model FSEC Registration Number Strings' Shortest String` Longest String` Total Hyundai Heavy Industries Green En HiSS290RG HH17-NT90-0134 3 10 11 31 I •torcyetevo using ACW modulesorme—dera,Wsdata reAeda bench ch to ratherdmn0tvs Inverter Manufacturer Inverter Model Min.Input Voltage Max.Input Voltage Max DC Input AC Power Rating Output Voltage SMA SB7.7-1SP-US-40 100 V 550 V 7,950 W 7,680 W 208/240 V Charge Controller Manufacturer Charge Controller Model Battery Manufacturer Battery Model IBattery Type Capacity(C/20 rate) JQuantity N/A N/A N/A N/A N/A N/A WA Review Comments Inspection Electrical Design(Verify the following items for agreement between the installed components and the supplied electrical schematic.) ❑Size,type and location of all conductors in the PV system; ❑Conduit,raceways,junction boxes,and combiner boxes; o Size,current rating,voltage ratings,and location of all over-current protection devices; ❑Rating and location of all disconnects; ❑Point of connection to the utility; o PV module and equipment grounding system(including conductor size); 1 ❑PV DC circuit and system grounding(including grounding electrode conductor size); / / ❑Ground fault detection&interrupter(GFOI)rating and location; I� ❑Battery wiring and cable sizes(if applicable). i Inspector Name(printed) Inspector Signature Date '.I Installer Information and Certification Company Name: Website: Address: Phone Number: Florida Contractor License Number. Florida Contractor License Type: 1 ❑Solar ❑Electrical ❑Other,please specify: }� I hereby certify that this PV system has been installed in full accordance with the National Electrical Cade. Installer Name(printed) Installer Signature Date Note: FSEC approvals do not replace or exempt any requirements of electrical utilities or local jurisdiction authorities in matters such as permitting,inspections,or utility interconnection agreements as required for PV system installations. When referring to FSEC approvals in any documentation produced by the supplier,including technical or marketing information,the fallowing statement shall be included: 'The photovoltaic system design described in this manual,when property installed and maintained,meets the minimum recommended practices established by the Florida Solar Energy Center. This approval'does not imply endorsement or warranty of this product by the Florida Solar Energy Center or the State of Florida." i Solar Testi 9r Certification oordinator Standard�203 SMA S137.7-US Inverter with Hyundai HIS-S290RG Modules 8.99 kW DC Photovoltaic System Electrical Diagram with (3) Series Strings 1-11, 2-10 5 6 7 8 s Optional Supply Side Connection NEC 705.17A ToN-de' s2so- _ U--�Modules 1)Hyundai HiS-S290 in series L1 G N N M GEC re capper 3)06 1 UNai.mefer THHNRHWN-2 2ooA $290- 3l4"PVC condole .. #10 60 A fused RG disconnect with - Hyundai HiS-S290RG 40A fu SMA SB7.7-US Inverter fuses existing Main Distribution grounding Panel Module Specifications Pmax:290 Wp Max.Input DC Voltage:600 VDC szso (10)Hyundai Max ISC per string: 18 A RG —� QQU*h HiS-S290RG VOC: 38.8 V 200A Panelboard with Vm 32.0 V MPPT Range: 100-550 VDC Modules in series pp' Max Output Voltage:240 VAC 200 A Main breaker Isc: 9.7 A O6)#10 AWG PV Wire 3-R,3-B (1)#6 AWG Bare Copper Impp: 9.1 A Max Output current: 32A(AC) 3 200A.2 .C.Voltage. -0.30/61C AC Nominal Power:7680 Watts O (6)#10 AWG THHN/THWN-2 Notes: All work to meet or exceed NEC 2011 OO 3-13,3-11 0Junction box to be located within the array boundary. Junction box must be minimum Nema 311 UL listed 10 (1)#8 AWG THHN/THWN-2 enclosure.Free air conductors must be installed in raceway if readily accessible as per 690.31(A). Nema 3R 1-G Orhe minimum volume of the Nema 311 enclosure for the transition of PV wire to THWN-2 wire shall be 11 Junction 3/4"EMT,FMC(inside structure 48 cubic inches. Heyco 5 wire Masthead gland seals or similar connector are required as strain relief 40Al2 Box LFNC,PVC(outside structure) for PV wire into Nema 311 junction box at array. jp��_i 690.31E Olnterconnection with 40 Amp 2 pole OCPD via 2011 NEC 705.12(D)(2)Load Side Connection. The 40 A i backfed breaker must be located at the opposite end of the bus from the 200 A main supply breaker SMA Sunny Boy 7.7-US a@The required PV Backfed breaker plus the main breaker rating must be less than or equal to 120%of i Dc Transformerless Inverter with the Main service bus rating. 705.12(D)(2) exrstery n 9 OOptional Supply Side connection via 705.12A using parallel line taps in a NEMA 3R box(as required) ground'mg 4 p� integrated DC disconnect electrode • (4)#8 AWG THHN/THWN- using NSI IPCS4002, Ilsco IPC-KUP-L or NSI Tork IPLD 310-3 Multi-Tap Connector or equivalent. i ss - PV service disconnecting means for"optional"supply side connection must have neutral/EGC bond 1B,1-R,1-W 1-G i within and must be listed as"suitable for use as service equipment." 230.66 1 3/4"EMT,FMC,LFNC, OThe fuses in the disconnect for the"supply side"option must be rated to handle the maximum short- or PVC circuit current available at the supply terminals.110.9,110.10 Over-current protection for the supply side �••— -----•—• connected conductors shall be located within 10 feet of the connection to the service. 705.31 s0 Grounded conductor shall be routed with ungrounded conductors to PV Service disconnecting means as (4)#8 AWG THHN/THWN-2 per 250.24(C)if"Supply Side"option is used. 1-B,1-11,1-W,1-G sO For"Supply Side option" Continuous or irreversibly spliced Grounding Electrode Conductor installed 3/4"EMT,FMC,LFNC,or PVC per 250.24(D). Grounding Electrode Conductor shall be specified as per 260.64 and sized per 260.66 8The following label is required on meter can and main panelboard"Services fed from dual power sources Utility and Photovoltaic system" ff required by Utility 71 "PV input Do not relocate this OCPD"label required adjacent to backfed breaker. 705.12(d)(7) 60A 240V AC Disconnect with label On-site Utility Generation 73 12 onding of module to rail and module to module accomplished through WEEB washers or self grounding Disconnect Switch DC Disconnect Label Requirements mid-clamps. Vmpp 352 vdc 13 "Warning:DC conductors of this system are ungrounded and may be energized"required on the MaxV459 vdc DC Disconnect 690.35E PV AC Disconnect Label Requirements 14."Warning:Photovoltaic Power Source"label required on conduit per 690.31(E)(3)(4) Operating Current:32 A Impp 27.3 A 15. Total voltage drop%for all circuits based on listed conductors is 1.640/6 Operating Voltage:240 VAC [max 36.37 A 1 16. Fuses are required on positve and negative conductors of systems with 3 or more strings(source circuits). POLY 6oAf NECiE1V E �a CEL 410 LINE ® it / 1 i1 r t� e f 1 ' YEAR'*"""""------------------------1-7��I PRODUCT WARRANTY GUARANTEED POSITIVE POWER 25 YEAR SORTING:(0;+4.99 Wpj AVAILABLE IN PERFORWNCE 10D0 V OR 1500V SYSTEM VOLTAGE RA "_-- -- -- TING MANUFACTURED ACCORD ^' HELIENE INC. QUALITY SYSTE RD1NG TO INTERNATIONAL MANUFACTURER A PREMIER M STANDARDS.ING IS09001 r SERVICING THE SOLAR MODULE `" —_ SOLAR ENERGY GROWING MARKETS OF NORTH t ;� . "COMBININGP AMERICA, H-BLACK WITH ROVEN EUROPEAN TECHNOLOGY ION AVAILABLE t HELIENE TO II AMERICAN INGENUITYq(LO ARE (ALL-BLACK MODULE) M A REAL COMMITMENT/N S ( 1 N�A R p E PROVIDING SMARTER RF 0 R M A THE FUTURE Y CHOICES FOR N E GUARANTEE ENERG ��v 700,ODo/ Ours ®ltodust HELIENE _'" ..».-�..,...,�, c 95.00% q© --.__,_�ls�dartl !I�!heliene.c - 00% 80.009. >0.00% N ` Year N N ry N N N 60N ELECTRICAL DATA(STC) DIMENSIONS I' HELIENE ROM I I Peak Rated Power ; P Pp(W) p 305 ' 300 1 295 290 ; 285 Maximum Power Voltage Vmoo(V) 33.44 33.14 32.$44 32.537 32,236 I Maximum Power Current s Impp(A) 9.196 i 9.127 ¢ 9.06 8.989 ; 8.92 _ 992 mm -- — - �I Voltage Circuit Open Voc(V) -�39.981 39.83 39.68 39.528 39.38 40 mm P g amm Short Circuit Current Ise(A) 9.673 9.59 i 9,51 s 9.424 9.34 � E faxo9mm Module Efficiency* j Eff(°I°} 18.9 18.5 1$.3 18.D 17.7 tz -4 ( Power Output Tolerance 0,+4.991 Wp STC-Standard Test Conditions:Irradiation 1000 W/m2-Air mass AM 1.5-Cell temperature 25°C I I *Calculated using maximum power based on full positive output tolerance[-0,+4.991 Wp j MECHANICAL DATA °R°°bmdeHm� Dimensions(L x W x D) 1650 x 992 x 40 mm(65 x 39 x 1.6 inch) E; Weight* 19.9 kg(43.9 Ibs) tq 10.5mm Output Cables 1.1 m(43.3 inch)symmetrical cables with MC4 type connectors I8xa4mm Junction Box IP-67 rated with bypass diodes Frame I Double webbed 15 micron anodized aluminum allay �� �Qmm -•- - - --� Front Glass Low-iron content,high-transmission PV solar glass Solar Cells 9 60 Monocrystalline cells(156 x 156 mm) *Calculated using 3.2mm PV glass,if 4mm profile is requested weight load will vary I-V CURVE FOR HELIENEBOM SERIESCERTIFICATIONS UL Listed ULC/ORD-Cl703-1,1.11-1703,UL1703 Fire Classification Type 1 -�-�-- IEC Listed �— IEC 61215,IEC 61730 a - -- All Heliene modules are certified under the California Energy Commision(CEC)Listing Report 3 -- TEMPERATURE RATINGS PACKAGING CONFIGURATION- r y g,asio v+s za 75 sa sus 40 46 sa Nominal Operating Cell ^ Modules per box: }� 26 pieces t Temperature(NOCT) +45°C(±?°C) _ Modules per 53'trailer: 936 pieces Temperature Coefficient of Pmgx -0.39%/°C Po ' _. Temperature Coefficient of V i -0.31%/°C 8 Temperature Coefficient of 1. 0.045°I°!°C =E'El s to is xa ss �a ss as ss sa ' MAXIMUM RATINGS Operational Temperature i -40°C-+85°C Max System Voltage�I i DOW/1500V CERTIFICATIONS Max Series Fuse Rating " 15 A tr, L WARRANTY I� ek mcerrek F 10 Year Manufacturer's Workmanship Warranty-1 -, 25 Year Linear Power Guarantee p z (Refer to product warranty page for details),gob.1 w '1 CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. ® ©2017 Heliene Inc.All rights reserved.Specifications included in this datasheet are subject to HELIENE change without notice. SUNNY BOY 300-US / . -US / 5.0-US / .0-US / 7.0-US / 7®7-US G vA a.. I i i I I'j SPS WORLD'S FIRST g SECURE POWER SUPPLY C ® L US Value-Added Improvements Reduced Labor Unmatched Flexibility Trouble-Free Servicing • World's first Secure Power Supply New Installation Assistant with SMA's proprietary OptiTracT"' • Two-part enclosure concept now offers up to 2,000 W direct access via smartphone Global Peak technology mitigates allows for simple,expedited • Full grid management capabilities minimizes time in the field shade with ease servicing ensures a utility-compliant solution Integrated disconnect simplifies Multiple independent MPPTs • Enhanced AFCI technology reduces for any market equipment stocking and speeds accommodate hundreds of false tripping while improving installation stringing possibilities sensitivity in real arcs,greatly reducing unneeded service calls SUNNY BOY 3.0-US / 3.8-US / 5.0-US / 6.0-US / 7.0-US / 7.7-US Reduce costs across your entire residential business model The residential PV market is changing rapidly, and we understand that your bottom line matters more than ever. That's why we've designed a superior residential solution that will help you decrease costs throughout all stages of your business operations.The Sunny Boy 3.0-US/3.8-US/5.0-US/6.0-US/7.0-US/7.7-US join the SMA lineup of field-proven solar technology backed by the world's#1 service team,along with a wealth of improvements.Simple design,improved stocking and ordering, value driven sales support and streamlined installation are just some of the ways that SMA is working to help your business operate more efficiently. www.SMA-America.com Technical data Sunny Boy 3.0-US* Sunny Boy 3.8-US* Sunny Boy 5.0•US 208 V 240 V 208 V 240 V 208 V 240 V Input(DC) Max.usable DC Power 3100 W 3100 W 3450 W 3900 W 5250 W 5250 W- Max.DC voltage 600 V Rated MPP voltage range 155-480 V 195-480 V 220-A80 V MPPT operating voltage range 100-550 V Min.DC voltage/start voltage 100 V/125 V Max.operating input current per MPPT 10 A Max.short circuit current per MPPT 18 A Number of MPPT tracker/string per MPPT tracker 2/1 Output(AC) AC nominal power 3000 W 3000 W 3330 W 3800 W 5000 W 5000 W Max.AC apparent power 3000 VA 3000 VA 3330 VA 3800 VA 5000 VA 5000 VA Nominal voltage/adjustable 208 V./• 240 V/• 208 V/• 240 V/• 208 V/• 240 V/• AC voltage range 183-229 V 211 -264 V 183-229 V 211 -264 V 183-229 V 211 -264 V AC grid frequency 60 Hz/50 Hz Max.output current 14.5 A 12.5 A 16.0 A 16.0 A 24.0 A 24.0 A Power factor(cos(p) 1 Output phases/line connections 1/2 Harmonics <4% Efficiency Max.efficiency 97.2%* 97.5%* 97.2%* - 97.5%* 97.2% 97.5% CEC efficiency . 96.5%* 97.0%* 96.5%* 97.0%* 96.5% 97% Protection devices DC disconnect device • DC reverse polarity protection • _ Ground fault monitoring/Grid monitoring • AC short circuit protection • Opole sensitive residual current monitoring unit(RCMU) • Arc fault circuit interrupter(AFCI) • Protection class/overvoltage category I/IV General data Dimensions(W/H/D)in mm(in) 535 x 730 x 198(21.1 x 28.5 x 7.8) Packaging Dimensions(W/H/D)in mm(in) 600 x 800 x 300(23.6 x 31.5 x 11.8) Weight 26 kg(57 lb) Packaging weight 30 kg(66 lb) Operating temperature range -25*C...+60*C - Noise emission(typical) <25 dB(A) Internal power consumption at night <5 W Topology Transformedess Cooling concept Convection Features Secure Power Supply • Display(2 x 16 characters) • Interfaces:Ethernet/WLAN 0/0 Sensor module/External WLAN antenna 0/0 Warranty:10/15/20 years a/O/o Certificates and approvals UL 1741,UL 1998,UL 1699B,IEEE1547,FCC Part 15(Class A&B),CAN/CSA V22.2 107.1-1 •Standard features O Optional features -Not available Data at nominal conditions NOTE:US inverters ship with gray lids. *Preliminary data,UL pending Type designation SB3.0-1 SP-US-40 SB3.8-1 SP-US-40 SB5.0-1 SP-US-40 Accessories 4_ Sensormodule �t Exlemal WIAN antenna MD.SEN-US40 EXTANT-US-00 l � r--------------------------------------------------------------------------- r------------------? Preliminary efficiency curve SUNNY BOY 6.0-1SP-US-40 'r-------------------i '---------------------------------------------------------------------------' 98 94 io v 92-E• -- -- i 9' r 88-+----- - Eta(VH-220 VI_Ve 96 Era(Ve.-375 VI azo aeo 66.:.-_____-•• Eta(V„-480 VI 0.0 0.2 0.4 0.6 0.8 1.0 Output power/Rated power ----------------------------'----------------------------------------------------`---------------------------------------- i Sunny Boy 6.0-US Sunny Boy 7.0-US* Sunny Boy 7.7-US Technical data 208 V 240 V 208 V 240 V 208 V 240 V_, Input(DC) Max-ysable DC power 5500 W 6300 W, 6900 W 7350 W 6950 W 8100 W Max.DC Voltage'. , 600 V Rated MPP Voltage range 220-480 V 245-480 V 270-480 V MPPT operating voltage range 100-550 V -Min.DC voltage/start voltage 190 V/125 V Max.operating input current per MPPT 10 A Max.short circuit current per MPPT 18 A Number of MPPT tracker/string per MPPT tracker 3/1 Output(AC) AC nominal power _- 5200 W 6000,W 6660 W 7000 W 6660 W 7680 W Max.AC apparent power 5200 VA 6000 VA 6660 VA 7000 VA 6660 VA 7680 VA Nominal voltage/adjustable -208 V/• 240 V/• 208 V/_• 240 V/• 208 V/• - 240 V AC voltage range 183-229 V 211 -264 V 183-229.V 21 1 -264 V 183-229 V 211 -264 V AC grid frequency 60 Hz/50-Hz Max.output current 25.0 A 25.0.A 32.0 A 29.2A 32.0 A 32.0 A Power factor(cos P) 1 _ Output phases/line-connections 1/2 Harmonics <4 Efficiency ' Max.efficiency 97.2% 97.6% 97.1 %* 97.2 7.* 97.1%* 97.2 CEC efficiency_ 96.5% 97% 96.5%* 96.5%* 96.5%* 96.5 Protection devices DC disconnect device • DC reverse polarity protection • Ground fault monitoring/Grid monitoring AC'short circuit protection • All-pole sensitive residual current monitoring unit(RCMU) • Arc fault circuit interrupter(AFCI) • Protection class/overvoltage category I/IV_ General data Dimensions(W/H/D)in mm(in) 535 x 730 x 198(21.1 x 28.5 x 7.8) Packaging Dimensions(W/H/D)in mm(in) 600 x 800 x 300(23.6 x 3 1.5 x 11.8) Weight 26 kg(57 lb) Packaging weight 30 kg(66 lb) Operating temperature range -25°C..+60*C Noise emission(typical) 26 dB(A) 30 dB(A) Internal power consumption at night <5 W Topology Transformedess Cooling concept Convection Fan Features Secure Power Supply • Display(2_x 16 characters) • Interfaces:Ethernet/WLAN •/ - Sensor module/External WLAN antenna 0/0 Warranty:10/15/20 years •/O/o Certificates and approvals UL 1741,UL 1998,UL 1699B,IEEE1547,FCC Part 15(Class A&B),CAN/CSA V22.2 107.1-1 •Standard features -O Optional features —Not available Data at nominal conditions NOTE:US inverters ship with gray lids. Preliminary data,UL pending Type designation SB6.0-1 SP-US-40 S0.0-1 SOUS-40 SB7.7-1 SP-US-40 SAME NAME, NEW GAME The Sunny Boy 3.0-US through 7.7-US are once again raising the bar by offering improved performance, enhanced features, and most importantly, an economical approach to residential solar. Your business model is a value chain. The new Sunny Boy-US series can help you stay competitive in an increasingly price sensitive residential market by driving down costs across all of your business operations.