Loading...
HomeMy WebLinkAbout18-20183 CITY OF ZEPHYRHILLS 5335-8TH STREET' (813)780-0020 20183 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20183 Address: 7329 APPLEGATE DR Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ALPHA VILLAGE Est. Value: Parcel Number: 35-25-21-005A-00000-1020 Improv. Cost: 15,897.00 OWNER INFORMATION Date Issued: 9/10/2018 Name: RIVERA, JEREMY& BOBBIE Total Fees: 180.00 Address: 7329 APPLEGATE DR Amount Paid: 180.00 ZEPHYRHILLS, FL. 33542 Date Paid: 9/10/2018 Phone: (813)997-5208 Work Desc: REPLACE 10 WINDOWS S/S CONTRACTOR S - APPLICATION FEES HOME PERFORMANCE ALLIANCE INC' BUILDING FEE 180.00 Ins ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR IGNATURE PERMIT OFFICOR PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER o I.1:0 II MR • 5' City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �— Date Received: Site: Permit Type: 4-bkce- /0 Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Ka vi S i er—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) 813-780-0020 City of Zephyrhilis Permit Application Fax-813-780-0021 ^^�� Building Department G ' L , o Date Received �G" Phone Contact for Permitting 7� J -`4 I` 1 1 1 1 1 1 1 . . 1 1 1 1 1 Owner s Nametv-?Vr6l � + Owner Phone Number Owner's Address AfVI -t,-)r Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address ,\'/ f f� JOBADDRESS \r L r ^ l !`LOOT## V SUBDIVISION Q V �T PARCEL ID# 7� �I—lJl/v.!) a� (OBTAINED FROM PROPERTY T.NO WORK PROPOSED a NEW CONSTR B ADD/CLT I J� ISIGN Q QDEMOLISH INSTALL REP T� PROPOSED USE = SFR = COMM = OTHER TYPE OF CONSTRUCTION BLOCK and FRAME = STEEL QX^',`(� (1 j� DESCRIPTION OF WORK �7t'�(/1 �N Ui S 1 CF •1 L I Duna VW J I J�,�+ BUILDING SIZE SQ FOOTAGE� HEIGHT BUILDING $/ GJ� VALUATION OF TOTAL CONSTRUCTION ='ELECTRICAL $ I 1 AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C. I - * ,517 =PLUMBING $ //v l QJ t =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 1 t)D�11/ C � =GAS = ROOFING 0 SPECIALTY = ,OTHER /J FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES NO BUILDER W)CREGISTERED OMPANY 1 1 g c `• ce SIGNATURE IIAra Y/ FEE CURREN I Y/N Address I WAd Av a/ License# Ckf—tZ ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address I License# i OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# IIIIIIItlllllllllllllllllllllllllllllllllllllllllllllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) •' Agent(far the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Permit No. Parcel ID No 35-25-21-OO5A-000004020 NOTICE OF COMMENCEMENT 11111111111111111111111111111111111111111111111111111111lill State of Florida County of Pasco 2018140852 THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description Of Property: Parcel Identification NO. ALPHA VILLAGE ESTATES PH 2(0)PB 23 PGS e-9 LOT 102 OR 7477 PG 117e Street Address: 7329 APPLEGATE DRIVE ZEPHYRHILLS RCpt:1983806 ReG: 10.00 2. General Description of Improvement Replace windows and or doors,size for Size DS: 0.00 I T: 0.00 08/20/2018 L. K. , Dpty Clerk 3. Owner Information or Lessee information If the Lessee contracted for the improvement: RIVERA JEREMY P&BOBBIE JO Name 7329 APPLEGATE DRIVE ZEPHYRHILLS FL Address City State Interest in Property: Owner 100% PAULA S.0'NE IL,Ph.D.PASCO CLERK & COMPTROLLER 08/20/2018 04.21pm Name of Fee Simple Titleholder. OR BK 97 7 (If different from Owner listed above) PG 1210 Address City State 4. Contractor. Home Performance Alliance Name 1780 102nd Ave Suite 500 St.Petersbura FL Address City State' Contractors Telephone No.: (727)53B-4140 5. Surety: Name Address City State Amount of Bond: S Telephone No 6. Lender Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City State Telephone Number of Designated Person: 8. In addition to himself,the owner designates of— to receive a copy of the Uenoes Notice as provided in Section 713A3(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner.. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS.MADE,BY THE OWNER AFTER THE EXPIRATION:OF THE NOTICE OF COMMENCEMENT ER ARE CONSIDERED IMPROPER"PAYMENTS UNDER CHAPT 713 'PART 1;SECTION 713.13, FLORIDA"STATUTES AND CAN RESULT IN YOUR,PAYING.TNACE FOR IMPROVEMENTS.TO YOUR PROPERTY. A NOTICE-OF COMMENCEMENT' MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.'IF YOU INTEND TO OBTAIN.FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE-COMMENCING WORK OR RECORDING.YOUR.NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA '/ " � COUNTY OF PASCO Signature of Owner or Lessee,or Owner's or Lessee's Authorized Officer/Director/Partner/Manager Signaatto►rrys Title/Office The foregoing instrument was acknowledged before me this day of � 04— .20LI by acl�'BV J 6 P+V 51AA as (type of authority,e.g.,officer,trustee,attorney in fact)for _84=f 6 1-£A r4 (name of pgjAWn be fWfSom InStrt Went was executed). Personally Known j]OR Produced Identification 12 Notary Signature Type of Identification ProducediD.L. Name(Print) �A t� Ee ✓ 070-9-1- ?13-0 ,�<'�>,�,. BRIANCOTHERN *: MY COMMISSION#GG 214627 : Po? EXPIRES:May 6,2022 FOFO,. wpdata/bcs/nolicecommencement_pcOS3048 Bonded Thtu Notary Public Underwriters �c STATE OF FLORIDA, IDA,COMM OF����C� THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT rn G�rwe err ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNE flY HAND AND OFFICIALS AL THIS ray , ..� DAY OF � ' �. i887 � P ULA S. O'NEIL, �T -- MPTROLLER 0 �- BY E1'OTY CLERK NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED-CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has-hired--a-contractor-or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the'contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that T'ransportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07; as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Res66rce Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or v i final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify. that 1, the applicant, have been provided with a copy of the 'Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to delive'r it to the"owner'prior to commencement. CONTR CTORSIOWNERIS AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify',that I understand that the regulations of other government agencies may apply to the intended work,and that it Is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Welland Areas and Environmentally Sensitive Lands,WaterMastewater Treatment. Southwest Florida Water Management District-Wells,-Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material is to be used in Flood Zone 'K, it is understood that a drainage plan addressing a compensating volume will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone W in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill Will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I arn the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate,permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to Violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring, a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENPF=R OR AN ATTORNEY BEFORE RECORDING YOVR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F OWNER OR AGENJZL= _ ---'I CONTRACTORf"J!�� d smvwio jc!Mfore me thl Subscribed d forMthis A sw rn y iFit 0-2-2— by 0 4��)be Who' Are pepQnaJi known to me or 0 11 kn tome orhas/have produced VAI as ldendficatio-n. JW=k:Ms=m identification. Notary Public Notary Public , lmmi on 0. Gommissi 0. JACOUFLINE BU Y JACQUELME ROGES) ...... 41 r; 4— Name of Notary t 2,2015 Name of Notary typed,14=101--vinissien#Ff 160422 :.,i Expires DeceMb s December 12,2018 xplre Bonded Thru J'ay Fein Wded Thru Ttoy F&*ft Plan Review - .:W indows & Doors . 1) Need manufacturing install.atiorrspecifications: - 2) Must.meet sections R308 and 4612 of the 2017 F:B.C. 3). :If windows"are to be-installed inside:the historical district,they:will need to be approved: by the historical committee.. 4) No other work-shall lie permitted (framing, plurribing-and..' eclianical) unless otherwise specified: :- p (g . g ) y Y g y 5) This is-for re lacernent_ lass for lass onl .. If ou"w.ish to chan� a from screen.orvin l g . . q .. windows to. lass;then additional information is re uired. . 6)` All windows to-wall connectio.ns:shall be left.visible for. inspection. - 7,) All labeling and stickers shall remain on,windows until final inspection: 8.):. -No work shall:start without permit first:.:: Rivera,Bobbi 10&Jeremy WS Project Manager: Date: te.aer: Green Sky Sent to Friday,August 3,2018 _ Notes: Term. 8.50% $13,897.00 Measure: Rachel tender. Term. In Progress Inspection Required Class/Design Pressure in PSF 45(8.64) Wind Velocity in MPH 137' S11138 5 Bobbi Jo Rivera Cust.Name Jeremy Rivera OC' one Number (813)997-3536 Phone Number (813)244-9001 q2pp Cont.Date 7/28/2018 Address 7329 Applegate Dr =7 7 Zephyrhills,FL 33540 BA< MPA.ffA County Pasco Sales•Rep Jim Hill_ Ns Phone Number (702)750-7638 77. 6EP1 Z% 1 .�. Frame Type —KRENeIEW I Exterior Siding CO . YB 1990 L'1 V f 4 Zi Bucking Req N, Color W /3- x. , Grids Frosted VV 111�� Impact QtY Z. 0 i Non4mpact Qty. 0 N ►' SryO O � �M� ,v Window Shields Qty. Door Shields Q . )/Z l'S Cust.snit Customer agrees to the above Nr Room W H Style Series OBS Temp Screen Grids Notes 1 LlV�rG- (,7� $ s ry �vLL /"oT 2 L� v iti� 4 ^*1 S ov1Nl, 6 i aJ r^'&_ or 8 9 (� ��s (2 :S ASrt Lf2 T:x ?� r PyrT6 10 W1 A-�r�-K 11 IV,-2- 1�5 �d•� 12 13 AUG 3 2018 14 15 ^ � �1,Measured By: Date: Customer Signature: . Date: L Do you live in a flood zone: Yes or No (Please circle one) l l� Last Revision Date:0318 Page i of 12 Rivera,Bobbi Jo&Jeremy WS Bobbi Jo Rivera and Jeremy Rivera S�- 32, r r O � A,4 _E 2 FEP' 3 3 1£ // Last Revision Date:0318 Page 3 of 12 HOME PERFORMANCE AL.-JANCE, INC. State Certified General Contractor License#CGC1608826&CBC1258017 L 1780 102nd Avenue,Suite 500,St Petersburg,FL 33716 Home Performance Office:(727)538-4140*Fax(727)538-4217 www.hpaWindows.com-Email:help@HPAm(indows.com AL L I A N C E CONTRACT PqRCHASER NAME MAIN PHONE OTHER PHONE WORK PHONE C.,teffzm_1 60 22-: STREET E-MAIL 23Z AQD -A,N CITY,STATE,AN LP CUSTOMER ALTERNATE PHONE: SAL RE!p REPS PHONE DATE .77,7 General Description of Work. To furnish and install: !D Windows and 42462sliding glass doors and entry doors -which is further described in the details specification sheet attached hereto as Exhibit"K and initiated by the parties.We Will remove and dispose of all debris from job site.Price below includes building permits and warranty. The above workwill be completed in accordance with the terms,conditions and specifications herein,with payment to be made In accordance with the following payment schedule:' CASH CONTRACT I FINANCE CONTRACT I 1. PROJECT PRICE , $ 2. INITIAL DOWN PAYMENT $ 3. BALANCE DUE $ 4. ADDITIONAL DOWN PAYMENT DUE $ UPON DELIVERY OF.MATERALS, 5. BALANCE DUE UPON COMPLETION $ 6. BALANCE TO BE FINANCED $ BALANCE DUE UPON INSTALLATION OF WINDOWS AND DOORS NOT AFTER THE FINAL INSPECTION, Customer understands and agrees there may be items to be finished after the final Inspection. I.E.Plugs and trim,stress cracks,additional caulking,etc.which Is covered unddr warranties. PAYMENT IS TO BE MADE BY CHECK PAYABLE TO"HOME PERFORMANCE ALLIANCE,INC.-ALL APPLICABLE DISCOUNTS HAVE BEEN APPLIED AT TIME OF SERVICE. Additional Comments: All work is to be completed in a workmanlike manner according to standard practices.Any alteration or deviation from the above scope of work involving extra costs will become an extra charge in addition to the quoted price.Our workers are fully covered by Workmen's Compensation insurance Unless otherwise specified, Contractor's work carries a year limited workmanship warranty. The Contract Documents Consist of this proposal,the terms and conditions,all documents referenced therein and the Limited Workmanship Warranty and are incorporated herein by reference. Buyer's Right to Cancel: This is a home solicitation sale,and if you do not want the goods or services,you may cancel this agreement by providing written notice to the seller in person,by e-mail or by certified mail.Telephonic communications do not constitute valid notice of cancellation under this agreement.Saturday is a business day v for the purposes of this contract.This notice must Indicate that you do not want the goods or services and must be delivered or postmarked before midnight of the third business day after you sign this agreement If you cancel this agreement within-the 3 day Period the seller may not keep any cash down payment.If you cancel after the 3rd business day,you will be liable for a 30%liquidated damages fee in addition to loss of your deposit I HAVE READ AND UNDERSTAND THIS CONTRACT,THE TERMS AND CONDITIONS AND ALL DOCUMENTS REFERENCED THEREIN AND AGREE TO BE BOUND BY THEIR TERMS. ACCEPTANCE OF CONTRACT: The above prices, specifications Respectfully submitted, and conditions are satisfactory and are hereby accepted.Contractor is authorized to do the work as specified.By signing below,Customer HOME PERFORMANCE ALLIANCE,INC. acknowledges that Customer is the owner of the property where work is to be performed. Owner Signature!9C) By.-.(officer of Company) Co-Owner signalwaQ. r. Quotation custom WINDOW SYSTEMS By:Jeremy Kilburn Quote#: 1729424/1 1900 S.W.44th Avenue.Ocala,FL 34474 Ph:352-368-6922 Fax:352-368-2928 HOME PERFORMANCE ALLIANCE, INC i5ill To: Ship To: Cust PO#:BOBBI JO RIVERA SHIP TO 1780 102nd Ave.N. 9843 18th St.N. Route:StPet- ST PETERSBURG,FL 33716 ST PETERSBURG,FL 33716 Job Name:BOBBI JO RIVERA Ph:727 538-4140 Fax:727 538-4212 Ph:727 538-4140 Fax:727 538-4212 Version 1 Cust No.HOM450-P3368 Item No. 1 Qty:1 Model:8900 XO Color: WHITE _ Desc:8900 AB XO(OSLI Sliding Right)PVC-SGD DP:+60/-60'FPA#132 1.1�STD, 2 Track Frame,5 15/16"Depth,PVC 6040 Thresh Io d,PREMIUM ROLLER,WHITE Dimensions _ FRAME,18 x16 Screen,6068 71 v2 x 7s vz LOW E 366,Insulated,Tempered DLO:71 112 x 791/2 SCREEN:18 X 16 THUMBTURN ONLY,AL FXD PNL CLIPS,WELDED FRAME,PVC INTRLK SCREEN AAMA Std.Gold Labeling,(1737)SILLIRISER( Lf �=:'y Kk PAP L4 ,,, , . Disclaimers:PLEASE REVIEW FOR PRICING AND ITEM ACCURACY. This quotation is valid for 30 days.Pricing and availability are based on sizes and quantities listed on this quote.Changes in sizing and/or quantities may result in units having to be re-quoted and/or reviewed.Please verify all sizes,quantities and specifications prior to placing an order.Quote is subject to changes and corrections until it is signed and placed as an order.Mullions between units may indicate a need for additional structural support to be determined by the contractor or architect Additional support should be taken into account when calculating rough openings.CWS,Inc.does not recommend direct mulling above patio doors without additional support.'Thank you.' 8/15/18 9:26:08AM Page 1 of 1 ` cc �-{-�3� Dealer Quotation - Quote 173712 QUOTE EXPIRES VOftTTLl 10250 Philipp Plcwy Phone: (330) 528 3400 30 DAYS FROM W11 doves Streetsboro, OH 44241 Fax: (330) 528 3501 REQUESTED www.soft-lite.com Bid For Shipping Address HOME PERFORMANCE ALLIANCE INC 9843 18TH STREET NORTH 9843 18TH STREET NORTH ST PETERSBURG,FL 33716 ST PETERSBURG,FL 33716 Business: 727 538 4140 Fax: 727 538 4217 Quote Name: BOBBI JO RIVERA Customer Number PO j' Required Date Quoted By 707347 BOBBI JO RIVERA 8/15/2018 davism i Line Qty Description 10-1 1 BCN Multilite Window 71.75 x 48.5 Comment/Room: Viewed from Inside I � Q O .� t V LIVING Sill Type=SLOPED CC33 1 Base Color=Soft-Lite White Half Flex Screen Betterwe 71 E I Sill Expander=Y g Lock Type=Standard Lock Color=Soft-Lite White l �l ED Ell- Foam Fill=Spray Foam 1 Install Note=Yes 1-2 r- 35.375 a5.375 —� Reinforced Sash=Y 7.75 Double Locks=Y Glass Package=Solar Lowe&Argon Clear=Yes __ _�:NFRC vr�lueS Lowe=Solar Control SB70 .?U-FACTOR SHGC` a Argon Gas „u: Stainless Intercept VT CA-- `R Double Strength 0.45 57 Mull Type=JSM Vertical Factory 1"thick,48.5"length Wrap=G Page 1 of 5 Bid Dated: 8/15/2018 8:59 AM Customer Number PO Required Date Quoted By 707347 BOBBI JO RIVERA r j'8/15/2018 davism Line Qty Description 20-1 1 BCN Double Hung Double Hung 35.25 x 48.5 CommentlRoom: Viewed from Inside ROOM I Sill Type=SLOPED n Base Color= Cite White 08 /v�. Half Flex Screen en w Bettere ( Sill Expander=Y m Lock Type=Standard Lock Color=Soft-Lite White Foam Fill=Spray Foam U i Install Note=Yes 3 Reinforced Sash=Y 35.25 Double Locks=Y r--- RO-35.5�~ Glass Package=Solar Lowe&Argon _ Clear=Yes 1VFRC Valu- es 9 Lowe=Solar Control SB70 -t-FACTOR SHGC Argon Gas 0.3 0.19 Js Stainless Intercept VT CR Double Strength 0.45 57 Wrap=G Line Qty Description 30-1 1 BCN Double Hung Double Hung 51.25 x 48.5 Comment/Room: Viewed from Inside DINING Sill Type=SLOPED - 1 Base Color=Soft-Lite White Half Flex Screen enBetBetterwe Sill Expander=Y M,n 7 Lock Type=Standard & Lock Color=Soft-Lite White Foam Fill=Spray Foam U Install Note=Yes 4 Reinforced Sash=Y 5i,25 Double Locks=Y RO-51.5 —, Glass Package=Solar Lowe&Argon Clear=Yes —> "»1VFRC'OFlues': Lowe=Solar Control SB70 '`U-FACTOR "SHGC Argon Gas " 0.3 ;; 01I.9_. ,_, Stainless Intercept Double Strength 0.45 57 Wrap= Page 2 of 5 Bid Dated: 8/15/2018 8:59 AM Customer Number PO -Required Date Quoted By 707347 BOBBI JO RIVE '/ 8/15/2018 davism Line Qty Description 40-1 1 BCN Multilite Window 104 x 48.5 Comment/Room: Viewed from Inside DINING Sill Type=SLOPED Base Color=Soft-Lice White r� ®� f Half Flex Screen Betterwe `�) Cl Sill Expander=Y Lock Type=Standard 1— Lock Color=Soft-Lite White 'f l U L Foam Fill=Spray Foam l Install Note=Yes ( � O 2LO, sis su 5 l Reinforced Sash=Y Double Locks=Y Glass Package=Solar Lowe&Argon Clear=Yes t'rf NFRC'itc�lues Lowe=Solar Control SB70 U-FACTOR SHGC _ Argon Gas L. 0.3 6.19 1 Stainless Intercept VT "-"CR7 Double Strength 0.45 57 Mull Type=JSM Vertical Factory V thick,48.5"length Wrap=G Line Qty Description 50-1 1 BCN Double Slider XX 35 x 24.75 Comment/Room: Viewed from Inside BATH Base Color=Soft-Lite White T Half Flex Screen Betterwe Sill Expander=Y o ° N Lock Type=Standard Lock Color=Soft-Lite White _ N `=1 Foam Fill=Spray Foam t)o r. Install Note=Yes 1111 8 Reinforced Sash=Y 35 Double Locks=Y RO-35.25 Primary Sash=R Glass Package=Solar Lowe&Argon Lowe=Solar Control SB70 �-NFRC T/a ues Tempered=Yes U-FACTOR ,SHGC -� Standard Obscure s Argon Gas 0.3 - 0.19 VT-__ — -CR— Stainless Intercept 0.44 60 Double Strength Wrap=G Page 3 of 5 Bid Dated: 8/15/2018 8:59 AM Customer Number PO y'` Required Date Quoted By 707347 BOBBI JO RIVE 8/15/2018 davism Line Qty Description 60-1 1 BCN Double Slider XX 35 x 24.5 Comment/Room: Viewed from Inside MASTER T Base Color=Soft-Cite White Half Flex Screen Betterwe Sill Expander=Y Lock Type=Standard n — Lock Color=Soft-Lite White o Foam Fill=Spray Foam Install Note=Yes j,0 Q T: 8 1_ Reinforced Sash=Y F 35 Double Locks=Y RO-35.25 Primary Sash=R Glass Package=Solar Lowe&Argon Lowe=Solar Control SB70 r---NFRC V—a-lu s� Tempered=Yes �U=FACT_OR_ SHGC Standard Obscure 4.3 0.19 Argon Gas t ----VT— ICR--` ' Stainless Intercept 0.44 60 Double Strength Wrap=G Line Qty Description 70-1 1 BCN Double Hung Double Hung 3 x 48.7 Comment/Room: Viewed from Inside MASTER Sill Type=SLOPED P Base Color=Soft-Cite White 1 0 4 Half Flex Screen Bettervue Sill Expander=Y Lock Type=Standard Q Lock Color=Soft-Lite White Foam Fill=Spray Foam Install Note=Yes JI ]o Reinforced Sash=Y 36 Double Locks=Y �— RO-36.25 Glass Package=Solar Lowe&Argon Clear=Yes r-'N RC Values� �. Lowe=Solar Control SB70 s U=FACTOR SHGC Argon Gas 0:3 0.19' i Stainless Intercept VT V CR Double Strength 0.45 57 Wrap=G Page 4 of 5 Bid Dated: 8/15/2018 8:59 AM Customer Number PO A&qui red Date Quoted By 707347 BOBBI JO RIVERA 8/15/2018 davism. Line Qty Description 80-1 1 BCN Double Hung Double Hung 50.75 x 48.5 CommentlRomn: Viewed from Inside BED 2 Sill Type=SLOPED C) Base Color=Soft-Lite White Half Flex Screen Bettervue Sill Expander=Y Lock Type=Standard Lock Color=Soft-Lite White Foam Fill=Spray Foam Install Note=Yes 11 Reinforced Sash=Y 50.75 Double Locks=Y , RO-51 Glass Package=Solar Lowe&Argon Clear=Yes Lowe=Solar Control SB70 -U-FACTdk .19 Argon Gas --r Stainless Intercept Z---VT- ---Ck-- Double Strength 0.45 5 Wrap=G Page 5 of 5 Bid Dated: 8/15/2018 8:69 AM 8/17/2018 '" Florida Building Code Online BCIS Home Log In �.User Registration Hot Topics Submit Surcharge j Stats&,Facts Publications i .Contact,Us 1 BCIS Site•Map ' Links ,+ search'.'! Norida . 11 Product Approval y�M USER:Public User - - r - . y—d� Product AoprovalMenu>Product or AopllcaHon Search>Application List>Application Detail .. 3 +-• + = FL#_ - ,. FL13241-R3 ' � Application Type Revision Code Version 2017 Application Status Approved Comments Archived .Product Manufacturer Custom Window Systems_Inc: Address/Phone/Email 1900 SW.44th Avenue .. Ocala,:FL34.474: .. . (352)368-6922 Ext 291 jlathrop@cws.cc:. :Authorized Signature Kevin Pine. kpine@.cws.cc Technical Representative ]ay Lathrop -_ Address/Phone/Email . 1900 SW 44th Ave Ocala; FL,34474 (352)368-6922 Ext291 ; .. jlathrop@cws.cc:. Quality Assurance,Representative Arturo.Monteverde Address/Phone/Email 1900 SW.44th Ave • Ocala,FL 34474:, '(_352)368-6922 Ext 221 am ontevefde@cWs.cc Category. Exterior Doors Subcategory. Sliding Exterior_Door Assemblies . Compliance Method Evaluation.Report from a Florida Registered Architect or a Licensed Florida. ' :- Professional Engineer. . - Evaluation Report-Hardcopy Received_ -. . Florida,Engineer or Architect Name who developed the Lucas A.Turner,: Evaluation Report Florida License PE-58201 Quality Assurance Entity Keystone.Gertifications;inc. Quality Assurance Contract Expiration Date 07/21/2020 - Validated-By. Steven M. Urich, PE d Validation.Checklist-Hardcopy Received.'-. .. . Certificate,of'Independence FL13241 R3-COI .EvalReoort496C.piif . Referenced Standard and Year(of Standard) Standard ,Year AAMA/WDMA/CSA/101/I:S.2/A440=05 2005 ' PA"TAS 202 - 1994 -Equivalence of Product Standards . Certified BY - Sections from the Code. - https://wwW.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgvRk6bsvZ66FA9Q%2be33nyMnL7tHgERNj9RalIPUSF%2fl2Q%3d°/a3d 1/2 8/17/2016 Florida Building Code Online Product Approval Method. Method 1 Option D Date Submitted 09/28/2017 Date Validated 09/29/2017 ' Date Pending FBC Approval 10%02/2017 Date Approved 12/12/2017 Summa of Products Model,Number or Name Description i 13241.1 SGD-8900 PVC Sliding Glass Door. SGD-8900;.Sliding Glass Door,..16080,OXXO,Nohi Impact. e Installation Instructions. Approved for use in HVHZ:Yes FL13241 R3 II CWS-496C;pdf Approved for use-outside HVHZ:Yes Verified By: Lucas A.Turner 58201 ' .Impact Resistant:No Created by Independent Third Party:Yes Design Pressure: +N/A/-N/A Evaluation Reports Other:See Installation,Detail for DP and Max. Sizes,OXXO, FL13241 R3 AE .EvalReport496C.pdf OXO, OX,&XO.Glass Complies to ASTM E1300-04. Created by Independent Third Party:Yes . Contact Us::2601 Blair Stone Road;Tallahassee FL 32399 Phone:850-487-1824 - - The State of Florida,is an AA/EEO•employer.-Copyright 2007-2013 State of Florida. Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic . .. mail.to'this entity..Instead,-contact the office by-phone or by.traditional mail.If you have any questions,please contact 850.487:1395.*Pursuant to Section 455.275(1), :Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must providethe Department with an email address if they have one.The emails . provided may be used for official communication with the licensee.However email addresses are public record.If you.do.nof wish to.supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee unde'r'Chapter 455,F.S.;please click here. Product Approval Accepts:' Credit Card Safe hfps://www.floridabuilding.6rg/pr/pr app_dtl.aspx?param=wGEVXQwtDgvRk6bsvZ66FA9Q%2be33nyHnL7tHgERNj9RaIIPUSF%2fl2Q%3d%3d 2/2 GENERAL NOTES: SLIDING GLASS.DOOR - NON-IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNEDAND MANUFACTURED: TO COMPLY WITH THE FLORIDA BUILDING:CODE(FBC),CURRENT VYiPIDOh/.SYS7fMS' EDITION AND IS RATED FOR USE IN THE HIGH VELOCITY.HURRICANE 1900 SW 44TH AVE. ZONE'(KVHZ).l OCALA,FLORIDA 34474 WWW CWSCC 2:GLAZING OPTIONS:(SEE SHEET 2): 3,APPROVED CONFIGURATIONS INCLUDE:BUT ARE NOT LIMITED TO: 89,00 PVC,SLIDING_ 19PU .MAX:OVERALL WIDTH. "XO","OX"1OX01."OXXO": `GLASS-DOOR .48_518".MAX 41 112 4.DESIGN PRESSURE:RATING.(SEE SHEET 2):.: NON-IMPACT PANEL WIDTH. A GLASS DLO NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE'AND GLASS TABLES ASTM E-1300-04e01/09. . -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER 4 z 'Q'z - - INFILTRATION TEST PRESSURE AND GLASS TABLES' p w O ¢F O W . - ASTM E-1300.04e01109. w ;Z J 2 <t 2_'W MAX 5.'ANCHORAGEi THE 33'1131/STRESS INCREASE HAS NOT BEEN USED a. F w z F 3: _ IN THE DESIGN OF THIS PRODUCT:SEE SHEET 7 FOR ANCHOR z z=' _w Ili O O. OVERALL B R DETAILS. WINDLOAD DURATION FACTORCd=1.6 WAS USED FOR WOOD �.O z a a HEIGHT O X X I 85 718"' ANCHOR CALCULATIONS: p z- z z-I-p vy GLASS t B. z O'Z:Utzp.t2- MAX 7 DLO 6.NOT APPROVED FOR IMPACT RESISTANCE.IMPACT PROTECTIVE } Q tt:w O 0 U.Z PANEL C SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION.' .2 0 H H z L)- . HEIGHT �' 7 7.ALL FRAMES ARE PROCESSED AND SCREWED TOGETHER.'VENTS', w 0 %to a w in w I. ARE FULLY WELDED. a :z ow O'r vi I- 93" p, 'wP0 a.w, LU.i }- 3�_.._� 8.SERIES J MODEL DESIGNATION,SGD-8900: a r :n LU�a A A 7 9.THE DESIGNATION X AND,O STAND FOR THE FOLLOWING:• X=OPERABLE SASH,:O=FIXED.SASH '• .P.......... . W T�Qi's 10.SECTION CALLOUTS APPLY TO ALL CONFIGURATIONS IN A SIMILAR .--`ti� $F'`•,2�g JAU&".,MAX.OVERALL WIDTH'_ LOCATION. ��' No 58201" :P 9.5_1/2";MAX.OVERALL WIDTH *: k �*t 'MAX 4.1 1/2". 11.WEEP SLOTS 1]4";x 1-1/41'LOCATED 3",FROM BOTH ENDS. - PANEL WIDTH GLASS DLO 4$AN/.r .MAX.: : 41 t12" -wt_ ;¢, PANEL W@TH 'GLASS DLO . %9;.'STATE OF :Wp .� :4u OR 953t2° LUQS$ 10NA} y MAX. 95112" " . Turner- OVERALL: MAX. . . . HEIGHT OVERALL . 201M&30 C C. HEIGHT ; 17:12+20:00 ox p. X: - O 'MAX. PANEL ll 8/28/2017 f 0 X HEIGHT 115-m I . m 85 718„ GLASS.. MAX GLASS: LUCAS A.TURNER,A.E. DLO PANEL DLO FL PE#5820.1', . HEIGHT 1239 JABARA AVE. :NORTH PORT,FL 34288. PH.941-380-1574' SHEET DESCRIPTION: 'GENERAL NOTES AND ELEVATIONS' TABLE OF CONTENTS' MAX: PANEL SIZE DESIGN PRESSURE.RATING IMPACT.RATIING DRAWN BY: DATE: GENERAL NOTES&ELEVATIONS.....1 ADE - 16/30109 GLAZING DETAILS.&.DPCHART.+...:...2' Owa#: REV.: SECTION VIEWS.......................:......3a SEE COMPARATIVE'ANALYSIS BOM&.EXTRUSIONS.............:.:...........5 " : 48-5/8 '.93. NONE CWS a96 C. ANCHOR SCHEDULE&NOTES..,..._...6.' CHART,.SHEET.2'. - lNSTALLATION DETAILS:...:..:..........:..? MAX:OF FOUR.(4)PANELS IS ALLOWED AS LONG AS INDIVIDUAL PANELS DO NOT EXCEED PANEL SIZE AS SHOWN, a� 1:4,0 s SHEET " 1 OF 7 59:5 71.5. . gq . . Width 95.5 '91 109 126 145_ _ 11$ Panel Size 30.625 36:625 42.875 .48,625' 30:625 36.625 42.25 48.625 30.625 36 625' 42 625 48 625 Unit Configuration OXXO OXXO OxXO COO ONO. OXO . Heighf. .Glass Type OXO' OXO ' OXXO OXKO OXXO OHO 1900 SW 44TH AVE: 80: A. 901+60. -90J+60. 82.2l+6Q' , .-72l+60. . '9Q/+6Q ' 9Q/+6Q $2.2/+6Q OGALA.FLORIDA 3aa74 ' A -72l+60 90/+60: =90/+60• 822/+60 72/+6Q �'----ws.cc. -9Ql+6Q 87:3/+60 78.4/+60 ': 8.5/+60. 90I#60 87.3/+60 -78.4/+60. .-68.51+6p =9Q/t60 87:3/+6Q 7&.41+60. 6g;5/+60 90 A -90/+60 $0l+60 -71.6/+60' =64I+60 . 90/+60 -80/+60 ::-71.6l+60 641+60 90/+60 : 80t+60 Z1.6/+,60 -64/+60' 96 A -85.3/+60 -73.8/+60 _ -65.8/+60 +60/60- $5.3l+60 73.8l+60 -65.81+60 +60!60. -85.3/+fiQ. .=73:$/+60 65.$J+60 00 PVC SLICING 'GLASS-DOOR NON=IMPACT a .z Www.lo ¢wo:d o UJ ,zOz w—._ IL. Ia-.uOi�zFo,w�s z zamwoo.. L — O . OI-T�-..OtiaSF-tC 1"OVERALL zd. _z1Q0z:_O . 3l16"TEMPERED.. O w 0 2 0 z y z 5/8"AIRSPACE p p F }j 0 _. 3 TEMPERED - - /18"T PEREp 0 w' a: w'= u}i Q' :n .z$a SIKAFLEX S52-OR 13:PURFECT GLAZE.°H^ N%O P130RFtiy TG4� 41 No 58201 U. h U. 13/15" GLASS.BITE t . . . .. . . . . y Q: STATE OF :40 8/28/20 t 7 LUCAS'A.TURNER,P.E.. FL PE#58201' 1239 JABARA AVE. - 8, NORTH PORT,FL 3428 PH 941.380 1574 - - - 'SHEETDESCRIPTIDN: *060 E DP' COMPARATIVE ANALYSIS G AND GLAZING DETAILLASS TYPE A DRAWN BY: DATE: ADE 10/30/09 . NOTE: IF SIZE INTENDED IS NOT SHOWN,USE NEXT LARGER SIZE. "INSTALLATION WITH NO SILL RISER DWG a. REv.:. ALLOWED ONLY WHERE WATER CWS-496 C', E IST INFILTRATION R S ANCE-iS NOT' SCALE; REQUIRED:_ SHEET 1.1 20F7. 25 4 .23. 7 5 1 . 2 0-14 16 }`aJUa]1f 4lI!/ • WINDOMLSYSTEMS, 1900 SW 44TH AVE Q OCALA,FLORIDA 34474 91 -5 ❑ WWW.CWS.CC. 68900 PVC.SLIDING.GLASS DOORa NON, IMPACT �a o0 0 a z z w_,o ¢ ❑ o z.conzi 0m z .Z w -Z f.- =, 1 5 30 33 6 19 2 8 9 19 1 O � 'wp0�. SECTION VIEW'B=B ❑ "z— Z z y z OOO�j-❑U— <" .F"zLLgpOu:U }o �.DFF'FOZ W 00 LL U)c IX w3a� ;pw�uir�� J4Q6'�.CENgGQye. 58201 " . - f O STATE OF' :�� . 33. 30 8/28/2017 4 LUC SA FL'PE#58 Oi. R.P.E. �(' 1 I 10 1239 JABARA AVE. 15" I 3. " :NORTH PORT, FL 34288 MAX SHEET DESCRIPTION: �� 14 SILL RISER POSITIVE DP SECTION VIEWS NONE 60 oxxo- 1 . '1737 � fi0 DRAWN BY: DATE: APE .16/30/09 3 INSTALLATION.WITH NO SILL RISER" Dwc RE SECTION VIEW A-A: ALLOWED ONLY WHERE WATER CWS 496 C INFILTRATION RESISTANCE IS NOT• REQ UIRED SCALE: SHEET. 1;2 67 . 3 OF 7 MIINDOW,SYSTEMS' 1900 SW 44TH AVE. OCALA,FLORIDA 34474 • 1 1 13 5 16 14, "2 1 3. 24 . 8900.PVC SLIDING �. O GLASS-DOOR NON=IMPACT ❑� .: ❑. a Z az� aa� 8 O p oa owp QWop Lu Wdoz Z . fn nn .Z F:W:§aO3�F- �." 81 W�pO 1�e O . O(.O.a. Fa. e ZZZ9 ?Z. Uto o j a F-Z:o.WZ=oZ 0 6 18 25, 30 .Z 8 9 : 19 ¢ 2 F-'V~?w w LL Ofrni.owUnw SECTION VIEW GC r .z m.wa O�v)r D, _ o O—u� O. 'w.r p a.x > a ' F. a .a�w(?. a. ,Q��1ACREW� 71 . 5 G 26 18 2 "No 58201 •%15 '.P , 'STATE OF nn a g . XZ 8/28/2017 °p "CAS'A.TURNER,P E' FL PE#58201 1239 JABARA AVE. 1 ., 5 30 33' 6 : 19 NORTH PORT,FL 34288: SECTION VIEW.D-D PH.941-38011574 SHEET DESCRIPTION: . . SECTION.VIEWS .. .. .. DRAWN BY: DATE: AIDE 10/30/09 DWG#: REV.: CWS=496. C. NOTE:VERTICAL SECTION SIMILAR FOR ALL'CONFIGURATIONS,SEE SHEET 3'. scA E: SHEET 1;2.63 : . '4 0F'7 PARTS LIST FRAME CONSTRUCTION ITEM PART NO.DESCRIPTION VENDOR MATERIAL 5 15/16'' 1 H-6042 FRAME,MAIN;SGD MIKRON. PVC 3/4" � '1 z" 2' S-6040 THRESHOLD/FILLER SGD MIKRON PVC w 32 VWNDOW SYSTEMS 3 S3038. SUPP.ORTBLOCK,F00=D;.SGD : . MIKRON PVC O —�1 Q — _ — 190D,SW 44TH AVE: 4 H�032 PANEL TOP/BOTTOM RAIL, SGD MIKRON PVC' 1 7/8' O 11ni Q 1 3/4", OCALA,FLORIDA 34474 5 H-6032•PANEL SIDE RAIL,SGD MIKRON PVC.' —— — WWW.CWS.CC, 6 H-6033 PANEL,INTERLOCK,FIXED MIKRON PVC. �[ I��DOC1� 1/8" 055. —— — 7 H-6034 PANEL,INTERLOCK,OPERABLE MIKRON 'PVC 8 H3035 INTERLOCK,SNAP=ON, _ MIKRON PVC. PVC OUTER FRAME: PVC WELD SUPPORT. $900 PVC-SLIDING 9 H-6043' ASTRAGAL;SGD, 'MIKRON H-6042 S-6046 Pvc• GLA$S DOOR 10 P3142 ROLLER.TANDEM(SGD,PLATED STEEL) STEEL FRAME CORNERS 11 .P3342 SEAM SEALER SM-5504 1 7/8",--1' 1:718" 1 7/8 SCREWED TOGETHER NOWIMPACT 12 .-P3352 SETTING BLOCK,85 DURA/81 X7/8"X2" -RUBBER I 1:10. 13 P3438 SIKAFLEX552 OR PURFECT GLAZE"H" SIKAIHENKEL ¢ O z . a z ' 14 P3 VENT CONSTRUCTION 492 WSTP.,0.270 X.187,BACK FINSEAL GRAY 5 F= o w 0 'p w O z - w-o. ¢' o . 15. P3539 #8 X3/4"QUAD PHILIPS;TEK ZINC w z.0 z of z 16 P3557' #10 x 2,HEXiEAD;TEK ZINC 3 9/16" 3 9/16" 3 9/16". w z:0� 17 P3752 CAP PLUG,1/2"HOLE NYLON z. z=m¢D_w O 0 18 P3767 #10 X1"HEX WASHER HEAD,•TEK ZINC 00 OO~OF U a 2 F-af 19 P3789 LOCK&HANDLE KIT;PVC,SGD STEEL_ ,/8" p z z H�'y c,z 20 P3792 3/4"KEEPER STEEL 1/8• 118" \ z O O O W z O V- :21 P-3793 MORTISE LOCK STEEL g r •¢ 0 w 0 O Z 22 P-0136,#10 x 2,PAN HEAD PHIL;SMS F¢- W� }0 3 O 23 5-1590 REINFORCEMENT,PVC SGD,PANEL KEYMARK ALUM PVC PANEL INTERLOCK PVC PANEL INTERLOCK PVC PANEL LOCKSTILE VENTS FULLY.WELDED w Ow 0 o �=) co w 24: 7 S-1591 REINFORCEMENT,ALUMINUM,SGD;PAN KEYMARK ALUM 'H3033 H-6032 1:10 .(L Z-a- Ir 0 to 25 S-1618 FIXED PANEL COVER' KEYMARK ALUM p w r 0 a= T 10 26, , S-1597 COVER,I'VED PANEL CLIP KEYMARK ALUM 1518"� a I.- a CC wa 27• 5-1655 PANEL TRACK,ALUMINUM,SGD,SILL KEYMARK ALUM 2 1l87 23 1 5/8" 7l16" tµ REi, 28 S-1726 REINFORCEMENT;ASTRAGAL,SGD- KEYMARK. ALUM. 050' 30 �P�...OR..... li 29 S-1737 HIGHRISE SILL,.ALUMINUM • KEYMARK ALUM - 4 g�� P,......,, lG�i�� 11/8" • 5;• 30 56037 GLAZING BEAD 1.00",SGD MIKRON PVC 1-15/16". 15/16": 13/16" : P DENS•' Q 4 31 S3041 TRACK,SCREEN,SGD. MIKRON PVC IL 1/8" 1— L z,: No 58201 32 S-6046 SUPPORT WELD,SGD MIKRON PVC REINFORCEMENT ROLLER TRACK PVC GLAZING BEAD 33 GLASS SEESHEET2 REINFORCEMENT S-1591 S-1655 - S-6037 = r�= S-1590 - �9 S STATE-OF .�: 5.1/16" .. .5!8",=�- ►�: �i�o<cs <.. ..1O..'��=,:`. J 2" 2 1/16" 1/2" p0 1/8" 0. 25 6 d 8 9 3 3/8"D I I 4 3/8 3.1/16". 2 5/8" 3 3/16" 0 2 13/16" 8/28/2017 D a 0 1/16" 1/16" LUCAS A.TURNER,P.E, h 1b16" FL-PE#58201 :1239 JABARA AVE. FIXED PNL CLIP FIXED P.NLCOVER. - PVC INTERLOCK SNAP HIGHRISE NORTH PORT,FL 34288 ASTRAGAL S-1618- S-1597 H-6035 S-1737 PH.941-360-1574 H-6043, REINFORCEMENT SIHEET DESCRIPTION: S 1726 BOM,AND EXTRUSIONS. . -9H6 - ,1/16", ; DRAWN BY:. DATE: 1114-3 ADE 16/30/09 1116" I DWG#: REV.: 1/8C CWS-496 C PVC SCREEN TRACK. ' PVC FIXED PANEL LIFT. PVC TRACK FILLER SCALE. NOTE:ALL EXTRUSIONS.ARE ALUMINUM 6063 T6 UNLESS OTHERWISE NOTED. �041. SHEET. S 6038 S 6040- 1:2 5 OF 7 18" MAX.O.C:(TYP.} �:�/ttVW/LtUU. 6 MAX. TYP; VANDo SY5TEN8, • ( 3 (TYP.) .. ' SEE NOTE 2 1900 SW 44TH AVE.' 6"MAX.(TYP.), .X (TYP,) OCALA,FLORIOA.34474 .WWW CWS CC 8900 PVC SLIDING. -. GLASS DOOR INSTALLATION NON-IMPACT. ANCHOR(TYP.). { 18... a .z .Qz ! ).C.. �. wLuA . Q�0Io w zoz w t= u.' r-w zr cgs' z zx:-¢awOo !' O Oh.O aT i z -O.Lry U — O zF�t13 <C �zag00'u Z a � 0�.��0 j��...... ���}�30m . w' 0�0 vrnwinw a s~W'CL W�wco. a I a 0: a � I ANCHOR LAYOUT-{FLANGE) _ ..i. Na 58201 :31•- 'STATE OF '�C "F NOTES:. ,rrrrrSl�NA 1:INSTALL TWO ANCHORS AT EACH INSTALLATION LOCATION..SILL ANCHOR SPACING SAME AS'HEAD, 2.SHIM AS REQ ATEACH.INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.'ALLOWABLE SHIMSTACK TO BE 1/4'. USE SHIMS WHERE SPACE GREATER THAN 1/16"IS PRESENT. LOAD BEARING SHIMS SHALL BE y rL CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER,WOOD SHIMS ARE NOT ALLOWED. . 8/28/2017 3.ANCHOR TYPE,SIZE;SPACING AND EMBEDMENT SHALL:BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 7. LUCAS A.TURNER,P.E. 4:ALL INSTALLATION'ANCHORS MUST BE MADE OF OR'PROTECTED WITH'A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR.METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED.WOOD MUST FL PE#5820.1' BE PROTECTED TO PREVENT REACTION. -, 1239 JABARA AVE. 5:INSTALLATION ANCHORS SHALL BE IN'ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM NORTH PORT,FL 34288 SPECIFIED IN TABLE 1,SHEET.7. . PH.941-380-1574 SHEET DESCRIPTION: 6z ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR'CONCRETE)CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD.BUCKS,IF USED,INTO SUBSTRATE:-1 X BUCKS ARE ANCHOR SCHEDULE AND OPTIONAL. NOTES' . 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:2-7/16"FOR MASONRY,2"-FOR FIXED PANEL CLIPS(ALL-SUBSTRATES),.1"FOR WOOD AND METAL. DRAwN ev: DATE: 6.WOOD OR MASONRY OPENINGS;BUCKS AND BUCK FASTENERS SHALL.BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND.LOADS'TO THE STRUCTURE. ADE 10/30/09 SUBSTRATES SHALL'MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 7. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED, DWG : REV.: 9:SEALING AND FLASHING STRATEGIES FOR'OVERALL'WATER RESISTANCE'OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRE_NT•VERSION OF THE REFERENCE DOCUMENTS: . CWS 496 C FMA/AAMA100(FINWINDOWS),.FMAIAAMA20D(FLANGEWINDOWS), FMAfWDMA250(BOXWINDOWS),FMAIAAMAANDMA300(EXTERIORDOORS)' SCALE: SHEET - 125 6 OF 7 .. . 'TYPICAL HEAD ANCHORAGE: _ _ _ -- - _ _ .. MIN.EMBEDMENT 2 7/16" SEE TABLE.11 MIN.EDGE DIST.SEE TABLE 1 1/4" MAX.SHIM WINDOW SYSTEMS: INTERIOR' 1900 SW 44TH:AVE. SUBSTRATE BY.OTHERS. OCALA,FLORIDA 34474 SEE TABLE'1 'MIN.EMBEDMENT W W W.0 W S.CC S � E T 1 T. EE,TABLE 1. fl MIN.EDGE.I LJ SE ABLE 8900,PVC SLIDING' . qOm QD Pq ❑ GLASS'DOOR PERIMETER_SEALANT . 4 I 114".,MAX.SHIM - INSTALLATION ANCHOR 2 7/76'. BY INSTALLER d SEE TABLE 1 NON-IMPACT INSIDE'AND OUT i <. Z. <zo .F _ o'w0 Qwop' INSTALLATION:ANCHOR INTERIOR w Z O Z x Z't SEE TABLE.1 ❑ o �>Om�m F w Z�-3:_m x 'Z Zx:2<wujpO. O OFO(j¢axFm (n�Z I_cn D: inZ.�=,—:)Ci PERIMETER SEALANT.BY INSTALLER Z O Z:O m Z�U INSIDE AND OUT I r Q-3 0 O-�0-OLLZ J yj w SUBSTRATE BY.OTHERS. a m .N m PERIMETER SEALANT II 11 SEE TABLE 1 ' �_ p'm ai o w 9 w Q U B. 'HORIZONTAL SECTION w m w O_j rn F BY INSTALLER m Z-a - �� f ti T� 7 TYPICAL JAMB ANCHORAGE a -x m O w INSIDE AND OUT LI p , w 1.-O 'a x_ r DO NOT COVER. w w W r a y WEEP HOLES MIN.EMBEDMENT SEE TABLE 1BY OTHERS SEE TABLE 1 ,,S�P"OREm/ INSTALLATION ANCHOR JGP ��6ENS` py� SEALANT UNDER SCREW SEE TABLE 1 �+: 'No 5820� HEAD BY.INSTALLER -2 7/16" - MIN:EDGE DIST. TWO ANCHORS PER. 1/4" SEE TABLE 1 FIXED CLIP THROUGH, L„-1 VERTICAL SECTION PRE-DRILLED HOLES 1.9116" STATE OF 7 TYPICAL SILL ANCHORAGE. 1- la! (TYP.). 2 1116" TABLE 1:APPROVED INSTALLATION FASTENERS SUBSTRATETYPE' ANCHOR TYPE . . MIN:EMBEDMENT MIN.:EDGEDIST. CONCRETE(2.0 KSI MIN.) 3/16-RW7APCON 1". 3 ]$p ❑ Z� CONCRETE(2:85 KSI.MIN.) 3116"ELCO ULTRACONMAX.O'C' 8/28/2017 HOLLOW OR GROUT-FILLED CMU(ASTM G90) 3/16 ELCO ULTRACON. 1-1/4 1 (TYP.) ' 2XMIN,SPRUCE-P.INE-FIR(G=0.42) 3116"ITW TAPCON OR 1 3/8"• 7/8" FIXED PANEL'CLIP' LUCAS A.TURNER'P.E: ELCO ULTRACON NOTE:CLIP.ANCHORS FL PE#58201 2XMIN.SPRUCE-PINE-FIR(G=0:42) #10•WOOD SCREW 1-318"' 7/8" MUST�BE LOCATED � 1239 JABARA AVE. A MINIMUM DISTANCE NORTH PORT,FL 34288 S GAUGED(33"j MIN. 910-16 HILT]KWIK-FLEX OR ITW FULL THREAD. 112" OF 3"FROM ANY PH.941-380-1574 STEEL STUD(33 KSI YIELD MIN). TEKS SELF.-DRILLING SCREW THRU 0.060"' MAINFRAME ANCHOR. � SHEET DESCRIPTION:, 1/8"ALUM.(6063-T5 MIN.)OR: #10 GRADE:5 SELF-TAPPING/. FULL THREAD. ` 1/8"STEEL(33 KSI MIN.) - DRILLING'SCREW THRU 0.125" 1�2" INSTALLATION DETAILS FIXED PANEL CLIP ANCHORS INTO CONCRETE(2:0 KSI MIN.)OR HOLLOW:OR 3/16"ITW TAPCON ' p 3,r SUBSTRATE BY OTHERS DRAWN BY: DATE: GROUT-FILLED CMU(117 PCF MIN. FIXED PANEL CLIP DETAIL SEE TABLE 1 ADE 1 U/30/09 FIXED PANEL CLIP ANCHORS INTO ^ Dw q: REV.: CONCRETE(2.85 KSI MIN.)OR HOLLOW OR 3/16"ELCO ULTRACON' 1-1/4": 2-1/2 ( v LHORIZONTAL SECTION GROUT FILLED CMU(ASTM G9f) 7 FIXED PANEL ANCHORAGE CWS-496 C NOTE:FIXED PANEL CLIP ANCHORS INTO WOOD OR METAL SHALL FOLLOW.THE ANCHOR TYPE,MIN.EMBEDMENT AND MIN.'EDGE DISTANCE LISTED IN TABLE 1. C E1:2.5 5 SHEET :7 OF'7 8/17/2016 Florida Building Code Online Tat BCIS Horne j Log In ( User Registration {:Hot Topics J Submit Surcharge 4 'Slats&Facts. 'Publications I Contact Us i BCIS Site Map :.Links !.Search i. Florida . 4 i Product Approval S.. - USER:Public User r � - Product A6proyal Menu>Product or Auplication Search>APbllcatioin Ust>Appllcatfon petal) ' .. . . - - " FL'# FL15780'-R8 a. Application Type Revision. . Code Version 2017 Application Status - Approved Comments Archived . .,Product Manufacturer Soft-Cite L'LC Address/Phone/Email 10250 Philipp Parkway Streetsb oro,.OH 44241 (330)528-1136. , PLangan@soft lite.com Authorized Signature- -Vivian-Wright :rickw@;-wbldgconsultants.com Technical Representative Address/Phone/Email . Quality.Assurance Representative, Address/Phone/Email . Category Windows'. . Subcategory Double Hung Compliance Method, : Evaluation Report from'a Florida Registered Architect or a"Licensed Florida- Professional.Engineer . . ' Evaluation.Report Hardcopy Received Florida.Engineer or Architect.Name who developed the Lyndon-F.' Schmidt,RE: Evaluation'Reporf Florida License. . _ PE-43409 Quality Assurance Entity : Farabaugh Engineering and Testing,Inc ' Quality Assurance Contract Expiration Date 12/31/2018 Validated By. . ... Ryan-1 King;P.E. . Validation Checklist-Hardcopy Received • Certificate of Independence FL15780 R8 COI (p)Certificate of Iridependence.pdf' Referenced Standard and Year of Standard Standard:. (. ) .. Year AA MA%WDMA/C5A101/I.S.2/A440 2008 AAMA/WDMA/CSA101/I.S.2/A440 2011 AAMA/WDMA/CSA101/I.S.2/A440. .2005 ASTM E1886_: 2005 - - ASTM- E1996 2006', - ASTM E1996 2 609 TAS 201, 202i 203 1994 Equivalence of Product Standards Certified By Sections from the Code http4://www.floridabuilding.6rg/pr/pr app_dtl.asox?param=WGEVXQWtDgt3elSAInEOW6yPiCno6ELk3nHvFWLjoQahBYdouwDiUg%3d%3d 1/3 8/17/2018 Florida Building Code Online Product Approval Method Method 1 Option D Date Submitted 06/11/2018 Date Validated 06/13/2018 Date Pending FBC Approval 06/18/2018 . Date Approved 08/15/2018 Summary of Products FL# I Model,Number or Name Description ! 15780.1 !a. "I LS DH12"Double Hung Extruded P.VC Double Hung Window-(X/X Configuration) Window Limits of Use I Installation Instructions Approved for use in HVHZ: No. FL15780 R8 II '(a)Inst 15780.1.pdf Approved for se outside'HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E. 43409 Impact Resistant: No Created by IndependentThird.Party:Yes Design Pressure: N/A Evaluation Reports. Othem See INST 15780.1 for Design Pressure Ratings, any FL15780 R8.AE (a) Eval 15780,1.pdf additional use limitations, installation instructions and product Created,by Independent Third Party: Yes particulars. 15780.2 b. "5400 DH54(135405)" Double Extruded PVC Double Hung Window- (NIX Configuration) 1 Hung Window Limits of Use Installation Instructions Approved for use in HVHZ: No : FL15780 R8 II (a)Inst 15780.2.pdf. Approved for use outside HVHZ;Yes, Verified By: Lyndon-F.Schmidt; P.E. 43409 Impact Resistant: No Created by Independent Third P.arty:.Yes Design"Pressure: N/A Evaluation.Reports Other:See INST 15780.2 for Design Pressure Ratings,any 1`1_15780 R8"AE (a) Eval 15780.2-.Rdf additional use limitations, installation instructions and product Created,by-IndependentThird Party:Yes. particulars. . . 15780.3 c. "5400 DH54(G5405)"Double Extruded PVC Double Hung Window-(X/X Configuration) Hung Window Limits of Use Installation Instructions Approved for:use in HVHZ:Yes: FL15780 R8 II (a)Inst 15780.3:pdf. Approved for use outside"HVHZ:Yes Verified B Lyndon F.Schmidt RE. 43409 _ Y� .Y. , Impact.Resistant:Yes Created by.Ind ependent Third Party:Yes Design Pressure: WA I. Evaluation Reports Other:See INST 15780.3 for Design Pressure Ratings,any -FL15780 R8 AE (b)Eval 15780.3:pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15780.4 d.,"5300 DH53.(G5305)"Double Extruded PVC Double Hung Window-(X%X Configuration)' Hung Window Limits of.Use, Installation Instructions Approved for-use in HVHZ: No : FL15780 R8 II (a)Inst 15780.4:pdf .Approved for.use outside HVHZ:Yes Verified By: Lyndon.R.Schmidt,P.E.43409 Impact Resistant: No: Created by Independent.Third Party:Yes De'sign-Pressure: N/A Evaluation Reports Other:See INST:15780'.4 for Design.Pressure Ratings,any FL15780 R8-AE-(a)-Eva.I 15780.4.pdf additional,use limitations, installation instructions and product Created by Independent Third Party:Yes particulars: 15780.5 e. "5300 DH53(G5305)"Double Extruded PVC Double Hung Window-(X/X Configuration):. . Il ,.Hung Window Limits of Use Installation Instructions. . Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.S:q�f Approved for.use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,:P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A I Evaluation Reports Other:See INST 15780.5 for Design Pressure Ratings,any I FL15780 R8 AE (b)Eval 15780:5:pdf additional:use limitations,'installation instructions and product -i Created by Independent Third Party:Yes. particulars. 15780.6 f. Series"Barcelona"Model."DH30I" Extruded PVC Double Hung"Impact"Window,-Missile Level"C" (X/X Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15780 R8 II (a)-Inst 15780.6.pdf Approved for use outside HVHZ:Yes Verified By:'Lyndon•F.Schmidt,P.E.43409 hfps://www.floridabui,lding.org/pr/pr app_dtl.aspx?pariam=wGEVXQwtDgt3e1SAInEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d 2/3. 8/17/2018 Florida Building Code Online Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15780.6 for Design Pressure Ratings,any .01-15780 R8 AE (b) Eval 15780.6.pdf additional Use limitations, installation instructions and product Created by Independent Third Party: Yes particulars: 15780.7 g.Series"Barcelona" Models .DH30I" Extruded P.VC Double Hung "Impact"Window, Missile Level"W' &"DH30PI" -.(X/X Configuration). Limits of Use Installation Instructions Approved for use in HVHZ: No. FL R8 If (a)Inst 15780.7.pdf Approved for use outside HVHZ:Yes -Verified By: Lyndon F. Schmidt, P.E. 43409 ' Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:N/A Evaluation Reports. Other:See INST 15780.7 for Design Pressure Ratings,any. FL15780 R8 .AE "(b) Eval 15780.7.pdf additional use.limitations, installation instructions and product I Created by Independent Third Party:Yes particulars: J 15780.8 h. Series"Barcelona" Models"DH30I" Extruded PVC Double Hung "Impact!'Window,High Velocity &"DH30PI" Hurricane Zone-(X/X Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes . .1`1_35786 R8.:II (a)Inst 15780.8.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party.: Yes . Design,Pressure: N/A Evaluation Reports. Other:See INST 15780.8.for Design.Pressure Ratings,any - FL15780 R8 AE (b) Eval 15780.8.pdf- I additional use limitations, installation instructions and product Created by Independent Third Party:Yes Part' lars. 15780.9 U ' --- — i.Series"Barcelona" Models"DH30" . Extruded PVC Double Hung "Non-Impact"Window--(X/X &."DH30P" Configuration) se Installation Instructions Approved for,use in HVHZ: No : FL15780 R8-II (b)_Inst 15780.9.pdf Approved.for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant: No -Created by Independent Third Party:Yes Design Pressure: N/A • Evaluation Reports . Other:See INST 15780.9 for Design Pressure Ratings,any - FL15780 R8 AE (ti)_Eval 15780.9.pdf additional use limitations;installation instructions and product Created b Independent Pa particulars. Y P rty:Yes Contact Us::2601 Blair Stone Road,Tallahassee FI.32399 Phone:850-487-1824 ' The State of Florida Is an AA/EEO.employen Copyright 2007-2013 State of Florida.'::Privacy Statement::Accessibility Statement:;Refund Statement Under Florida law,email addresses are public records.If you do'not'want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.'Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850:487.1395."Pursuant to section 455:275(1), - Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have'one.The emails' p�ovlded may be used for official communication with the licensee:However email addresses are public record:If you do not wish to supply a personal address,'please- _ provide the Department with an.email address which can be_made available to the public.To determine if you area licensee under Chapter 455,F.S.,please click here - Product Approval Accepts, . MTgCI�V, Credit Card Safe. . hfps://ww.w.flciridab.uilding.org/pr/pr_apo_dtl.aspk?param=wGEVXdwtC_gt3elSAInEOW6ypiCnocELk3nHvFWLJoQah8YcpuwDiUg%Sd%3d 3/3 t ® A•4•; �• 1r! � Wiz�dcaws (WA z �. . B?ingtng(.jv(.tl3L)1 TO light. l,���I7r rr�{1t p:n 1D z44, 10250 PhlGpp Parkway m o N•: Streetsboro,Ohio 44241 Co a s L x Z°0 z a \` N y tp 9 m 5 w 11, Itl SEE CHART FOR SEE CHART,FOR v a Y� m a a n. ARCELON FItAMESIZES. FRAMESIZFS W modal )H`30 and H30P . - a IL �OUIBLE F111NG /NDO1 ' X ZW _ o � . my. GENERAL NOTES < /. / Q)nw 1. This product has been evaluated and is in compliance•with the 6th Edition(2017)Florida w . i!f i`j a a Building Code(FBC)structural requirements excluding the"High Velocity Hurricane r r Zone"(HVHZ). s 2. Product anchors shall be as listed'and spaced as shown on details.Anchor embedment o to base materidi shall be beyond waft dressing of stucco. " 3. When used in areas requiring wind home debris protection,this product is required to be — protected with an impact resistant covering that complies with FBC Sections 1609.1.2&' W . in 'R3o1.2.1.2. Mode`"DH30" : Model"DH30P" W G A. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction.. . MA - = '.'MAX:-. GLASS.. : DESiGN PRESSURE(PSF), o a 5. Site conditions that deviate from the details of this dravv rig require,further � MODEL'_ FRAME; D.L:O.'.: a engineering analysis by o licensed engineer or registered architect. m _ „DIMENSION-' DlMENSION . : � - ROSlflVE. `NEGATlYE: _. PE _. "DH30" 36.0"X 72.0" •28.125"x 32.00" G1 +50.0 •50.0 TABLE OF CONTENTS m SHEET#-DESCRIMON. "DH30" 40.0"X 63.0' 32.125'x 27.125". Gi +55.0 --55.0 z 1. Typicalelevations,design pressures and genera notes DArE 9 19/17 2: Horizontal cross sections 9 "DH30" 54.0'.'X 76.0" 46.25'x 34.00".: c1 +35.0 •35.0, sue: N.T.S. 3 Vertical cross sections Dwc 0r JK' €. a 4 Buck and frame anchoring S. Components "DH30P" 40.0"X 63.0" 32.125"x 26.625" G1' +55.0 •55.0 CHK BY. .LFS 3 DPAWING NOs. � 6 Bill of materials and glazing detail � "DH30r' 54.0"X 76.0". .46.25"x.33.125". G1 +30.0. -30.0. FL--15780.9 0 O '' sHm I- OF 6 R:\Clents\Soft-Lite Permanent\A-Florida Product Approvals\FL-15780 Double Hung\C-Dmwings\FL-15780(2017)-R1\F1--15780.9.dwg,2 r O O CD z 0 _a cry m O 0 �n v� � O ? -0 � NW NN NISI 08 w p N rn ti � o � z T wN 3 W �•\\ �•�\ W W 13 Go � � N pN N oU O m O 22 J N S n A rota ' otn— on z O 70 � El W Ll0 m to Tv T ' z 0 I0 I0 N w m F2 a xa � ❑ ❑ . o ❑3 ww H ❑ W ❑ z N � _ n L1C3 0 o c Q V A O �t�uuriar/ O p ot� No.43409 JUNE 11,2018 PRODUCT: Document.Prepared ey: �• •• '1 SOFT—CITE WINDOWS Lyndon F. Schmidt �4 5''•�OF..... I I z to P.E. No. 43409 N 0 ` ;i PART OR ASSEMBLY: BUILDING CONSULTANTS, INC. o c� 1 6 11 18 ADDED FRAME SIZE JK VU P.O. Box 230, VDlrico, FL 33595 I°' 0. DATE BY HORIZONTAL Phone No.: 813.659.9197 REVISIONS CROSS SECTIONS FSPE CA No. 9813 ®201 7 R.W.BUILDING CONSULTANtS INC.' 1 R:\Olents\Soft-LIte Permanent\A-Florida Product Appro4s\FL-15780 Double Hung\C-Dmwings\FL-15780(2017)-RI\FL-15780.9.dwg,3 1-I/4"MIN. 1-1/4"MIN. r+ EMB.(TYP.) EMB.(TYP.) m m 0 0 N m — _ N •o w A A .o co om rn v S da oy _A RA Lr5 o N o N Z Z N p O O A to > I� O Z A O = T m m 1-1/4"MIN. Q EMB:[TYP.) .Np A N n m •o W O W W A w A C IA y 1.96" _ �m0 rn �D a ce o c o0 0 a 0 MOO H z l22 A 1-1/4"MIN. EMB.(TYP.) N M m t= D'o W N A P •O ❑ 0 N W{n tr o. ao Im �A 1a•' w � E6 o� c3 A ❑ �O N O N O O O ca 0 N z ca � v,.•�vc�iaE;••.r .� 22 1-1/4"MIN. I0 No.434D9 EMB.(TYP.) i JUNE 11,2018 x Q PRODUCT: Document.Prepared By. r�1 P SOFT—LITE WINDOWS Lyndon F. Schmidt � •�OR1Ct• ���J� I � tp P.E. No. 43409 ��j •���� I1 Lh O .. Z 1 �NA111"k • —i PART OR ASSEMBLY: �K�T��BUILDING CONSULTANTS, INC. o X in 1 6 11 18 DDED FRAME SIZE JK eJ l�Ul/ P.O. Box 230• Vairteo. Fl-33595 h 0. DATE BY VERTICAL ' Y Phone No.: 813.659.9197 REVISIONS CROSS SECTIONS FSPE C.A. No. 9813 0 20 17 R.W.BYILOINS CONSULTANtS INC. 4``�ttttt* tt rrrrr2i ¢ FOR WIDTHS GREATER THAN 40" W. — p n utN o V) z° o Em SmOd TYP. —. SASH a v w d �v m d a s ,2, BUCK o E `o z BUCK v FRAME—"' c ai . o 31 D. MEETING MEEnNG �^ RAIL o 2X BUCK F MASONRY 1 � OPENING 1XBUCK G o z LU MASONRY TO OPENING DMASONRY H m ---- SASH HEAD&JAMBS 5 (NP.) o z •. n a = •.�.�� �i. +�• ,y Z eta BUCKANCHORtN6 1� 'v 3 a FRAME ANCHORING ° z S N 0 g M o CONCRETE ANCHOR NOTES: ZE GI.Concrete anchor locations at the comers may be adjusted to maintain the min. edge distance to mortar joints. :5 2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to o d maintain the min.edge distance to mortar joints,additional concrete anchors = $ mby be required to ensure the"MAX.ON CENTER"dimension ore not exceeded. w m a Concrete anchor fable: tom-• MICJGL9RANC .MIN:;C4EARANC: „ ANGH�R-:x-NCRok iS i€:y:?11?1A1 i;'.is ;::;: .. B ;...,.......,:;r:r;>::..::...::.....:z•::>..;,.. ?::at]MAST NRY>:i 4QJA'.... S)ZE<i:::::_t NIBEDMENT:::::::... o 0 _._............_..EDGE:€:r;;.;;%?;: U :._..:...•.............._.-:........_...........:._..._.................--_._... ITW nay 9119117 E TAPCON® 1-1/4 22" A' swe: N.T.S. ° & ELCO d" 1" 4" MG.ea X m ULTRACON cNw yy; LFS 3 WOOD SCREW INSTALLATION NOTES: DRAW=ND- � 1.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.spacing of FL-15780.9 �- wood screws to prevent the splitting of wood. srM 4 or 6 N g — —... ri R:\Olents\Soft-Ute Permanent\A-Florida Product Approval5\FL-15780 Double Hung\C-Dmwings\FL-15760(2017)-R1\FL-1578D.9.dwg,S 0.059 2 8T' 0-059- 7L, IN A ----��{{{ o W -1 00 Fes—0.41" �I 'a p I � j 0.86" a L l I m 0.05, a F- 1.83" 1.21" I I 1.07- 1.05" IFS q I uJ N o r a 1.98, 0.39" �' o 1.07' w ? I O c m �_ = m w IJ tom' a ❑ 0.093" FFTI V N . 0.84"11 1.05 04U-1.63" I m I I 2.BT' s - n 0.065" r � I � 0.95 r p o y pa a O J o f/r W p H cy H N ¢1 2 lT QO f�0.66" r 2.39" � '\pl Z cc; T �I 11 � ,SCH.y Z � ``� vF��. Qr 0.2T L • No.43409 JUNE 11,2018 $ Q PRODUCT: Documanta Pmpom By:i� :• `� SOFT—UTE WINDOWS P.E. �<`{ps'•••..... L don F. Schmidt ��j � D.. to .E No. 43409 \ // Q�A�.; Vl P Z\ m /1111111{{, r r y PART OR ASSEMBLY: .+/� 81UILDINO CONSULTANTS. INC. ADDED FRAME SIZE JK r!li�P.O. Box 230, ValAco, FL 33595 O 20 NO DATE BY COMPONENTS Phan. No.: 813.659.9197 REVISIONS FBPE CA. No. 9813 ®2017 R.W.BUILDING CONSULTANtS INC. BILL OF MATERIALS ITEM i MATERIAL .���� '•"'/iJ�,� m A IX BUCK SG>=0.42 Q-' a 2 B 2X BUCK SG>=0.42 WOOD " =" C 1/4"MAX.SHIM SPACE N o 'z m z F•C` om D 1/d"X 2-3/4"PFH ELGO OR TIW CON CRETESCREW STEEL sty,:• ;�� z�� MASONRY-3.000 PSI MIN.CONCRETE CONFORMING TO ACI .,, � - E CONCRETE �,,� .....• Y;`.�� a>° m 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 o m m z F #8 X 2"PPH SMS(1-3B"MIN.EMBEDMENT) STEEL I�n+� UM.. G 1/4"X 2-314"HWH ECCO OR ii1N CONCRETE SCREW STEEL o Z,� H 1/4'X 2-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL C Em z m .0 a oa 1 FRAME" PVC T E u o 9 0 o w 2 HEAD' PVC ° a m a a T 3 WEEP HOLE COVER' PVC j ° 4 SILL ADAPTER' PVC - - 5 TOP LIFT HANDLE` PVC 6 KEEPER RAIL` PVC 7 LOCK RAIL' PVC 8 PLAIN STILE' PVC tn=' 9 GLAZING BEAD" PVC o � 10 BOTTOM LIFT RAIL' PVC z w� 11 REINFORCEMENT(6065-T5 ALUM) ALUM.* 3 � ' 12 REINFORCEMENT(6065-75ALUM) ALUM. 5/8 GLASS I/2 WiDEDBLSIDEDGIAZINGTAPE o 13 REINFORCEMENT(6065 T5 ALUM) ALUM. 7/8'THICK 14 HEAD POCKET INSERT' PVC i/8"ANNEALED OR TEMPERED GLASS Li m ry 15 SLOPED INSERT* 4 PVC 16 SLOPED SILL' PVC a a 20 LOCK _ 21 LOCK KEEPER _ m 3 25 TILT LATCH 0 26 #8 X I"PFH TEK STEEL AIRSPACE 27 #6 X 1"PFH TEK STEEL O 28 WEATHERSTRIP•(187-270TRI-FIN) - 1/89'ANNEALED OR TEMPERED GLASS 29 BULB SEAL STEEL INTERCEPT SPACER ra Z 0 30 BULB SEAL - GT GLAZING DETAtI y c�a 31 PIVOT BAR 32 #7 X 3/4"PFH TEK STEEL 33 1 BALANCER BRACKET 8 •THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY z EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". O u 8 z s Z 0 5 GaE 9119117 z' sc N.T.S. i MG.BY. JK m' CHK.BY. LFS 3 SS mPAWM ND- m FL-15780.9 n 0 0 sx�t7 6 of 6 w — — G '8/17/2018- " Florida Building Code-Online BCIS Home Log In ;.User Registration "Hot Topics .j Submit Surcharge Stats&Facts Publicattons ' contact Us I BCIS Site Map Links Search ko.- F1 _ • `Product Approval, USER:Public User :. .,t ''. . Product Approval Menu>'Product or Application Search,>A'g'plicatiodLtst>Application petal) . FL# ". FL16026-R2 Application Type' Revision, Code Version 2017 Application Status Approved" Comments Archived: . . Product Manufacturer :Soft-Lite LLC - Address/Phone/Email 10250 Philipp Parkway 4 . ._ . . Streetsboro,OH 442 Y (330)528-1136 . P La ngan@soft-lite.com • " Authorized Signature .. Vivian Wright _ - rickw@rwbidgconsultants:com Technical Representative Address/Phone/Email Quality Assurance Representative_. . Address/Phone/Email, Category.. - -Windows Subcategory ;. Mullions" Compliance Method Evaluation Report from'a Florida Registered Architect or a Licensed Florida Professional.Engineer u E4al ation Report-HardcopyReceived, Florida.Engineer orArchitect.Name Who developed the Lyndon F.Schmidt,P.E:- Evaluation-Report . Florida License' . . PE-43409 Quality Assurance Entity . Farabaugh Engineering and Testing,Inc Quality Assurance Contract Expiration Date' 12/31/2018 Validated By. Ryan I."King;.P.E. f "Validation_Checklist-Hardcopy•Received Certificate of Independence -: FL16026-R2 COI (a)Certificate of Independence,pdf Referenced.Standard,and Year(of Standard) Standard_ Year l 202, 263 1994 TAS 201; Equivalence of Product Standards ,Certified By Sections from the Code Product Approval Method• Method_1 Option D https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=WGE,VXQwtDgtFPmdYiNDWr65rLx4kiYK7stid4u1cguPeuW7M5Wb6re/o3d%o3d 1/2 8/17/2018 Florida Building Code Online Date Submitted 07/20/2017 Date Validated 07/31/2017 Date Pending FBC Approval 08/04/2017 Date Approved 10/10/2017 Summary of Products Model,'Niimlier or Name Description 1!ti .1 a.Series 19044 Structural Beam Extruded Aluminum Clipped Mullion for use_with impact andMullion non-impactwindow products in Masonry orWood Openings of Use " .. Installation Instructions Approved for use in HVHZ: No FL16026 R2 II ('b)Inst 16026.1.0_df Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, RE.43409' Impact Resistant:-Yes Created.by Independent Third Party:Yes' Design'pressure: N/A Evaluation.Reports Other:See INST 16026:1 for Design-Pressure Ratings,any FL16026 R2 AE ) Eval 16026:1.pdf, additional use limitations,'installation instructions and product Created by Independent Third Party:Yes particulars. 16026.2 b. Series 19044 Structural Beam Extruded Aluminum Clipped Mullion for use with impact and Mullion non-impact window products in Masonry or Wood Openings Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL16026 R2'II (b)Iilst 16026.2.pdf Approved.for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes Created.by Independent Third Party:Yes Design Peessured.N%A, Evaluation Reports,* Otheri.See INST 16026.2 for Design Pressure'Ratings;.any FL16026 R2 AE (b Eval 16026.2.pdf; additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars, ' - Contact Us:i 26011Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 .. .. The State of Fiorida'is an AA/EEO employer.Copy�ght 2b07-2013 State of Florida:::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not,send electronic'. - mail to this entity.Instead,contact the office by phone.or by traditional mail.If you have.any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), .Florida Statutes,effective October 1,2012,licensees licensed under Chapter455,F.S.must provide the Department with an email address if they have one:The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made ayailable10 the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. .. . .. ..Product Approval Accepts: . . . .. I - - Credit.Card Safe https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwEDgtFPmdYiNDWr65rLx4klYK7stid4u1cguPeuW7M5Wb6rg%3d%3d 2/2 • 1 — • 125'MAX.OVERALL FRAME WIDTH(TWIN) Llt 1"MULLION o Q:ii n �0=ATc 62"MAX.SINGLE 62TMAX.SINGLE -N;7 z •'O M�7 UNIT FRAME WIDTH UNIT FRAME WIDTH d%:, o m '•., 6J`, loin j.O(O m Bringing quality to light. .,/,�� ,p ``��• w> 1 m 10250 PM6pp Parkway ��� 1 11111 N m z Streetsboro,Ohlo 44241 o d ry a E o 9"Ng 9 56 L 19044 ALUMINUM MULLION , z b E o z 2 o0. �. 1d o GENERAL NOTES 2 ow $ 1. This product has been evaluated and is in compriance with the 6th,Edition(2017).Florida F' Building Code(FBC)structural requirements,excluding the."High Velocity Hurricane Zone". 3 1 When used in areas requiring wind borne debris protection,this product(if mulled together with. 2 v 3 impact rated windows)does not require protection from an impact resistant covering when' SASH NOT o w o used in Wind Zones 1,2 and 3 as defined by ASTM E 1996 and FBC Sections 1609.1.2.2& SHOWN MULLED TWIN.WINDOW.UNITS SHOWN & a a R3012:12.1. FOR CLARITY .(MDitiples also approved) o a N} 3. In Wind Zone 4,as defined by ASTM E 1996 and FBC Sections 1609.1.2.2&R301.2:1.2.1,this product must be protected with an impact resistant covering complying with FBC Sections_ m m 3 DESIGN PRESSURE(PSI) 4 .. 0 1609.1.2&R301.2,1.2.. 77 : �Y properly MAX SINGLE UNIT FRAME WIDTH .':...,...56"' �58" 4. Wood bucks b others;must be anchoredto transfer loads to the structure:and be 36 1.38 40" Q2-: ;44", '46" sI:�W' iiO 1S" 54 N N 60" 62":, z a reviewed by the Building Official. d o 90 .. 50 .48. 46 *.44. 42 40 39 ' 38 37 " 36 ..35' 35 34 34 w w o 5. Separate product approvals for each glazing product used with these mullions must be se^ 52' 50 48 46 44 42 41 40 39 38 37 36 36 35 submitted along with this mullion product approval.The design pressure rating of the assembly' o o shall,be'the lesser of the load,capacity of.the mullion as specified using this approval or the ,• 'S5 53 50 48 46 .45. 43 42. 41 40 3- 38 37 . 37. design pressure rating of the individual glazing;products used. 94",. 58 55 53 . 51 49'. 47 45 44 43' 42 41; 40 39 39 0 0 6. Anchoring.of each glazing productto the mullion shall be as shown in this drawing or.as shown;. H. 6�" b2 59 56 54 52 51 49- 48 46 45 44 43 42' .42 in each Individual,glazing . G5 62. 59 57 55 54 .52 . 51 49. 48' 47 46 46 45 g g product approval,whichever 1s more stringent. o' o„ .. �.. N.-Q ?. 78". '69 66 63 61 59 57 '55 54 52 51 50 50 49 48 7. Mullion anchor embedment to base material shall be beyond wall dressing or stucco. �' N z° i 76^._ 73 70, 67 65 63- 61. .59 58 56 55 54, 53 52. 52 a B. Any conditions not covered in this evaluation are subject to separate engineering evaluation. -. 94" 75 75 71 69. 67 65 63 62 60 59 58 57 56 56 DATE i 0/1 s/12 i - SUIE 0 TABLE OF CONTENTS 72 75: 75 . 75 74 72 70 68. 66 65 . 63 62 62 61 . 60' N.r.s: SHEET#- DESCRIPTION 70" 75. 75 75 75 75 75 73 71 70 69 67 66 65 65 owo.er: JK m cHN.er: LFS - 3 _ 1: Typical elevatlons,,design pressures&general,notes. 68'; 75: 75 75 75 75: 75 75 75 74 74' 73 72 7b 70 OpnW NG No.: r 2 Mullion deta.Us&cross sections• _ in %o N NO 66^ J5 75 75 75 75 75 75 ' 75 75 75 75 75 75 75 FL=16026.7 ro - sHc[r_L of 2 0.5" Shown with Soft-Lite fixed casement frame undetjy N separate approval. '#10 X 5/8"PPH SMS _•_ 2. o t o N' (4 each bracket) Oil *' 1.436" I 0.125'-y o '. ® i/� II r 1 PL ``` o n m z° 0.727. 9. a x Z DA77' N a`u a 9 m w 0.125' a` N 50.za m a0.T d Eq 1" E a� r�HORIZONTAL CROSS SECTION g.a o C4 N anchor clip MULLION 19044' 6063 TS ALUM. (4)Mullion Bracket anchors C3 required Into substrate a I---2.75 (See ANCHOR SCHEDULE) vi z Refer to separate window approval for quantity,location :z 3 5.5' &size of anchors required to fasten window frame to mullion. g W $ At a minimum,use#10 PPH Self-drilling SMS located 6"from z m •o ANCHOR BRACKET(18102) each end and spaced 18"max o.c: (a min.of 3 threads 6063-T5 ALUM. - 'must protrude through the mullion face). _ o, o o DE 11 WINDOW UNIT NOT a o o MULLION(19044)�r SHOWN FOR CLARITY a r21 HORIZONTAL CROSS SECTION z #lOX'5/8"FPHSMS:�� l g� P w, o v t rough mullion, 2 ANCHOR BRACKET(18102)' �h LL O° as 'MUTAON ANCHOR BRACk&ANCH6RSCHEDOIE - >j i : A:. : ENTER=TO•CENTER �vT o /1 ,SUBSTRATE.; ANCHOR, :EMBEDMEE NT'. ,EDGE'DISTANCE C - `' % w . a / 012 PFH WOOD SCREW ^SPACING' :..` v' •:WOOD. I-1/TMIN. I"MIN. 1-1/TMIN. .o Z s SUBSTRATE" (4)Anchors required into substrate 1/4°ow Pr1a 5 - ® (See ANCHOR SCHEDULE) CONCRETE'' ITW BUILDEKTAPCON®. I-I/4"MIN. 241T MIN. W/4'MIN- DATE:10116112 Z;,•:,.r•,, Dom' 3 ANCHOR BRACKET DETAIL SCALE: N.T.S. 9. € "'<`'"'+.12-14 HWH HIM KWIK-FLIX A MIN.OF iHRFnDs DWG.By.. JK m d #lOXS/8"PPHSMS 2 S1EEL'. SELF•DRILUNGSCREW SHALLPROTRUDETHROUGH 1"MIN. 1-1/TMIN. (2 EACH FACE) Fe THE STEEL SUBSTRATE CHK BY. LFS 3 .. �. - WOOD FRAMING S.G.r_0.55) .. DRAWING ND: N. . BRACKET-TO-MULLION DETAIL CONCRETE CONFORMING TO ACI301(3.000 PSI MIN.)OR HOLLOW BLOCK CONFORMING TOASTM C90 FL-16026..1 ^ STEEL,CONFORMINGTO ASTMA653,16 GA.,0,06UMM.THICKNESS(Fy=33,000 PSI,Fu 45.000 PSI) N 2 DF 2 8/17/2018 Florida Building Code Online * .' �®r, w a { { r ® r { :.:. BCIS Home I.Log In (..User Registration '�:-Hot Topic's'( Submit Surcharge I.Stats&Facts•I:Publications 1 ,contact Us I BCIS Site Map .Links t Search. Product Approval USER:Public User . .- Product'Aoproval Menu>Product or ligation Search.>ApplicationList>Application Detail. FL# FL15781-R8 Application Type- Revision. . Code Version 2017 Application Status. Approved - Comments - Arcftived:. Product Manufacturer Soft-Lite LLC Address/Phone/Email 10250 Philipp Parkway Streetsboro,.OH;44241' (330)528-1136.. PLangan@soft-lite.corri, ,. _Authorized Signature Vivian Wright' rickw@rwbldgconstiltants:c0 m Technical Representative Address/PhonejEmail . Quality.Assurance Representative. Address/Phone/Email, .. :Category - Windows Subcategory::. Horizontal Slider:. Compliance Method : Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report--:Hardcopy Received Florida Engineer or:Architect Name who developed the Lyndon-F. Schmidt, P.E.. Evaluation Report . Florida'License PE-43409 Quality-Assurance Entity Farabaugh Engineering'and Testing, Inc' • Quality Assurance Contract Expiration Date '12/31/2018 • Validated By. Ryan 1:Xing;P.E: Validation'Checklist-Hard copy Received Certificate of Independence. FL15781. R8 COI (b)Certificate of Independence.pdf Referenced Stand ard.and Year(of Standard) ' Standard Year AAMA/WDMA/CSA101/I.S.2/A440_ - 2011 AAMA/WDMA/CSA101/I.S:2/A440 - 2008_ _. ASTM E1300 2004. .. ASTM E1886 2005 ' ASTM E1996 . 2006 ASTM:E1996 009. TA5 201, 202, 203 1994 . , Equivalence of Product Standards Certified By Sections from the:Code https`.//wwW.floridabuildih§.org/or/pr_app_dtl.aspx?param=wGEVXOwtDgt3e1SAInE01N9Taf7MFDxJQgGR4F8K9N%2fsDYeoUiUZ2mQ%3d%3d 1/4.: 8/17/2018 Florida Building Code Online " Product Approval Method Method 1 Option D Date Submitted 02/13/2018 Date Validated 02/14/,2018 Date Pending FBC Approval 02/22/2018 . Date Approved 04/10/2018 Sum mary of Products FL# Model,Number or(dame Description 15781.1 a. "Imperial LS DSL12" Double Slider Extruded PVC Double Horizontal Sliding Window- (XX j Window Configuration) Limits-of Use Installation Instructions i Approved for.use.in HVHZ: No FL15781 R8"II "(a)Inst 15781.1.pdf Approved-for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409 Impact Resistant: No Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports 'Other:See INST 15781.1 for Design Pressure Ratings, any. . FL15781 R8.AE Ya) Eval.15781.1.pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes particulars. 15781.2 b. "Imperial LS.TSL12"Triple Slider Extruded PVC Triple Horizontal Sliding Window (XOX Window . Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No F1_15781 R8 II (a)_Insf 15781.2.pdf" Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt; P.E. 43409 Impact Resistant:No Created by Independent Third Party:Yes Design.Pressure: N/A. Evaluation-Reports. Other:See INST 15781.2 for Design Pressure Ratings,any FL15781 R8-AE (a) Eval 15781.2.odf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15781.3 c. "5300"DSL53 (G5352)"-Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of Use Installation Instructions Approved for.use in.HVHZ: No :" FL15781 R8 II (b),Inst 15781.3_pdf Approved for use outside HVHZ_:Yes Verified"By: Lyndon F:Schmidt;P.E.43409 Impact Resistant:.No Created by.Independenf Third Party:Yes Design Pressure: N/A. Evaluation Reports Othen See INST 15781.3 for Design Pressure Ratings,any FL15781 R8 AE (a)Eval 15781:3:pdf additional use limitations,installation instructions and product Created by Independent Third Party:Yes .particulars. f 15781.4" V d. "5300 DSL53(G5352)" Double Extruded PVC Double Horizontal Sliding Window-(XX Slider Window Configuration) Limits of:Use Installation Instructions: Approved for use in HVHZ: No FL15781 R8 II (b)_Inst15781.4iDdf Approved for use outside HVHZ:'Yes Verified By: Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes' : Created by,Independent Third Party:Yes Design Pressure:N/A Evaluation Reports' Otheri See INST 15781.4 for Design Pressure Ratings,any FL15781. R8 AE (a)Eval 15781:4:pdf additional use limitations, installation instructions and•product Created by Independent Third Party:Yes particulars. 15781.5 e. "5400 SSL54(G5402)"Single Extruded PVC Single,Horizontal Sliding Window (OX or XO. Slider Window Configuration)" Limits of:Use Installation Instructions Approved for.use in HVHZ: No FLI-5781 R8 II (b)Inst 15781.S,pdf Approved for use outside HVHZ:Yes Verified By: Lyndon.F.:Schmidt;-P.E.43409 Impact Resistant: No , " Created-by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See"INST 15781.5 for Design Pressure Ratings,any FL15781" R8 AE la)Eval 15781.5.pdf additional"use limitations, installation instructions and product Created by Independent Third Party:Yes particulars. 15781:6 f. "5400 SSL54(G5402)"Single Extruded PVC-Single Horizontal Sliding"Window (OX or XO Slider.Window Configuration) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781-R8 II (b) Inst 15781.6.pdf Approved r.use outside.HVHZ:Yes Verified B Lyndon F y y ..Schmidt,;P.E.43409 https://www.floridtibuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ%3d%o3d 2/4 8/1712018 Florida Building Code Online Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other:See INST 15781.6 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.6.pdf additional use limitations, installation instructions and product Created by Independent Third Party:Yes particulars'. 15781.7 g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal.Sliding Window-(XOX" Window.. Configuration) Limits of Use Installation Instructions Approved for use in HVHZ: No FLIS781 R8 'II.(a) Inst 15781.7.pdf Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt,'P.E..43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A . Evaluation Reports Other:See INST 15781.7 for Design Pressure Ratings,any FL15781 118 AE (a)-Eval 15781.7.pdf additional use limitations, installation instructions and product Created by'lndependentThird Party:•Yes particulars.. _J 15781.8 h. "54�00 TSLF54"Triple,Slider Extruded PVC Triple Horizontal Sliding Window-(XOX Wing dow. Configuration) "Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 118 II •(a)'Inst 15781.8.pdf Approved for use outside HVHZ_: Yes Verifed By: Lyndon F. Schmidt, RE: 43409 Impact Resistant:Yes Created by Independent Third Party:Yes Design pressure: N/A . - Evaluation Reports Other:See INST 15781.8 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.8.pdf. additional use limitations, installation instructions and product Created by.Independent Third Party:Yes particulars. 15781.9 i. Series"Barcelona"Model "SSL30I Extruded PVC Horizontal Sliding"Impact Window, Missile Level "C"Excludes Wind Zone 3'and 4(XO or OX Configurations) Limits-of Use Installation Instructions Approved for use in HVHZ: No FL15781' R8 II (b)Inst 15781.9 pdf - Approved.for use outside HVHZ: Yes Verified By:Lyndon F Schmidt, P.E.43409- Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure: N/A Evaluation Reports Other;See INST 15781.9 for Design Pressure.Ratings,any-. FL15781 R8-AE (a) Eval 15781.9.pdf " additional use limitations,installation.instructions and product Created by Independent Third Party:Yes particulars. 15781.10 j. Series"Barcelona"Model"SSL30I Extruded PVC Horizontal Sliding "Impact"Window,Missile Level "b".Includes Wind Zone 4(XO or OX Configurations) Limits of Use Installation Instructions Approved foruse In HVHZ: No FL15781- R8 II (b Inst 15781.10.pdf Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt, RE.'43409. Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:.N/A Evaluation Reports Other:See INST 15781.10 for Design Pressure Ratings,any FL15781- R8-AE (a)Eval 15781,1b:pdf additional use limitations,installation instructions and product I Created by Independent Third Party:Yes particulars. 1 15781.11 k. Series"Barcelona" Model"SSL30I" Extruded PVC Horizontal Sliding "Impact"Window,High, -1 Velocity Hurricane Zone Large Missile(No or OX Configurations). Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL1S781 R8-II (b) Inst 15781.11.pdf "Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 Impact Resistant:Yes: Created by Independent_Third Party:,Yes Design Pressure: N/A Evaluation Reports Other:See.INST•15781.11 for.Design Pressure Ratings,.any FL15781 R8 AE (a)_Eval 15781:11:12& additional use limitations;installation instructions and product I Created by Independent Third Party:Yes. particulars. - 15781,12 . I.Series"Barcelona"Model"TSL30I" Extruded PVC Triple Horizontal Sliding 'Impact"Window,Missile Level "C"Excludes Wind Zone 3 and 4(XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ: No FL15781 R8 II (by Inst 15781.12.pdf Approved for use outside HVHZ: Yes Verified By' Lyndon F. Schmidt, P.E.43409 Impact Resistant:Yes Created by Independent Third Party:Yes. Design Pressure: N/A Evaluation Reports Other:See INST 15781.12 for Design Pressure Ratings,any FL15781 R8 AE (a)Eva[ 15781;12.pdf additional use limitations,installation instructions and,product I Created by Independent Third Party:.Yes particulars. 15781.13. m. Series"Barcelona" Model Extruded PVC Triple Horizontal Sliding"Impact"Window,Missile "TSL30I"- Level"D".Excludes Wind Zone 4(XOX 1/4-1/2-1/4 and XOX 1/3-1/371/3 Configurations) hfps://www.floridabuilding.grg/pr/pr app_dti.aspx?param=wGEVXQWtDgt3elSAInEOW9Taf7MFDxJQgqR4F8K9N°/`2fsDYeoUiOZ2niQ%3d%3d 3/4 8/17/2018 Florida Building Code Online Limits of.Use Installation Instructions Approved for use in HVHZ: No FL15781 R8 II"(b)Inst 15781.13.pdf . Approved for.use outside HVHZ:Yes Verified By:"Lyndon F.Schmidt,RE,43409 " Impact Resistant:Yes Created by Independent Third Party:Yes Design Pressure:hi/A Evaluation Reports Other:-See INST 15781.13 for Design Pressure Ratings,any FL1578I'R8 AE (a) Eval 15781:13:pdf additional use limitations, installation instructions and product .Created by Independent Third'Party;Yes particulars. " 15781.14 n. Series"Barcelona"Model "TSL30I" Extruded PVC Triple Horizontal Sliding "Impact"Window, High . Velocity Hurricane Zone Large Missile(XOX 1%4=1/2-1/4 and XOX 1/3-1/3-1/3 Configurations) Limits of Use Installation Instructions Approved for use in HVHZ:Yes FL15781 R8"II (b)Inst 15781.14.Pdf Approved for use outside HVHZ:Yes Verified By:"Lyndon F..Schmidt, P.E. 43409 Impact Resistant:Yes Created by Independent Third Party:Yes . Design Pressure: N/A Evaluation.Reports Other:See INST.15781'.14 for Design Pressure Ratings,.any F1_15781 R8.AE (!I)-Eval 15781.14,pdf additional use limitations, installation Instructions and product Created by Independent Third Party:"Yes particulars. 15781.15 o. Series"Barcelona"Model "DSL30" Extruded PVC Horizontal Sliding "Non:Impact'"Window(XX Configuration) se Installation instructions. Approved for use in HVHZ: No. FL18781 R8 II (b)Inst 15781.15.pdf -Approved-for use outside HVHZ:Yes Verified By: Lyndon'F. Schmidt, P.E.43409 Impact"Resistant: No Created"by.Independent Third.Party:.Yes Design".Pressure: N/A Evaluation Reports Other:See INST-15781.15 for Design Pressure Ratings,any, F1_15781 R8-AE (b) EvaI 15781:15,pdf additional use.limitations;-installation instructions and product Created by Independent Third Party:Yes particulars.. 15781.16, Tp. Series"Barcelona" Model-"TSL30" Extruded PVC Triple Horizontal Sliding "Non-Impact"Window (XOX"1/4-1j2-1/4 and XOX 1/3-1/3-1/3 Configurations) Limits of Use; Installation instructions Approved for use in HVHZ: No - F1_15781 R8 II (b)Inst"15781.16,(�df Approved for use""outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409 Impact Resistant: No; '. Created by.Independent Third Party-Yes Design.Pressure: N/A I Evaluation Reports Other:See INST15781.16 for Design Pressure Raiings,.any FL15781 R8 AE'(l1)Ever15781.16: additional use limitations;installation instructions and product Created•by"Independent,Third Party:Yes; particulars. Contact Us::2601.Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824' ... ,. The State of Florida.is an AA/EEO employer.Copyright 2007-2013 State of Florida.:: r yacy Statement::Accessibility Statement:;Refund Statement . . Under Florida law,email addresses are public records:If you do not want"your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead;contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department-with an email address If they have'one.The emails provided-may be used for official communication with the licensee:However email addresses-are public record.If,you do not wish to supply a personal address,'please provide the Department with an email address which can-be made available to the'Public.To determine If you are a licensee under Chapter 455,,F.S.,please click,here'. - Product Approval Accepts: ® ® cLhccA M - Credit Card SaM https://www.floridabuilding.org/pr/pr_aop_dtl.asox?param=wGEVXQwtDgt3elSAinEOW9Taf7MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ%3d%3d 4/4 `0VVttV V. ixid .BTinging qualit:,1''to tigliL.. 10250 Ph pp Parkway SEE CHART FOR FRAME SIZES sir t``�� 'A , _ r 1111tV z d;6 Streetsboro,Ohio 44241 O Q.m,m G. a g ..=a 'eBARCELONA. � � N d Model "DSLM ��% x .0 N 310. SLIDING W[NbOW ,Q w- ¢c..) �v�3 GENERAL NOTES �. . . . ? o ,In 1. This product has been evaluated and is in compriance with the 6th Edition(2017)Florida o Building Code(FBC)structural requirements excluding the"High Velocity liumcana Zone" (HVHZ). 2. Product anchors shall be,as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or stucco: F 3. When used in areas requiring wind bome debris protection,this product is required to be z protected with an Impact resistant covering that complies with FBC Sections 1604:1.2& N _Q R301.2.1,2. w 4. For 2x-stud framing construction,anchoring of these units shall be the soma as that shown for 2x buck rnasonry construction. y 3 5. Site conditions that deviate from the'detalis of this drawing require further. Y' engineering analysis by a licensed engineer or registered architect, z 0 TABLE OF CONTENTS ,MAX::r•' ; `MAX, _'_- (P__. _o .o z, SHEEN DESCROTION -_ El ' 1 Typical elevations;design pressures and general notes. :..: DESIGNFRESStl- _S ' OtASS' :; z _ ,..FR;4NIE;';.,. ,: ;DaO:-.. -' :,. . ,,.: oAr5:10 08/77 z IYAE;` € 2 Honzontal cross sections ::DIMENSION:°: pfMENSIOM';,".. PO�fAVE.' 'iNEGATNE.i'. scuE N.T.S. B 3 Vertical or=sections 3 4 Buck and frome anchoring T3.0"X 63.0" 3T.431 x 54.375" G1. tQ0,0 -q0.0 °"� g" JK m 0 5 Components CHK Elf. , LFS 6 Bill of materials and lozin detail 63.W X 44.0"- : 26.437"x 35.37V' Gi + DRAWING rro.: rc s s &5.0 =55.0 � — 00ft-Lite _. 578 L t ELT 5 t OF' 6 O - . R:\Cllents\Soft-Lite Pennanent\A-Florida Product Apprmals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-1578L15.dwg,2.2 .. rn . . .. ao ^ O v F. n � T -V Z 7 =o . m � a a n w� rs w N A A .. . . .a a Ca Z Z - O A NW �n y O m Z z i J _ n _ N_ O to cn un 'D Z Q�i" G AS _ No.43409 PRODUCT: Documents Pmpcted'eyl i Lyndon F.'Schmidt" �i �ORIO�;•'• �� ' SOFT—CITE WINDOWS P.E. No. 43409 � s/pNAt6�� U1 D Z� �//11111111� n �_ r —1 to PART OR ASSEMBLY: BUILDING CONSULTANTS, INC.- v1 1 1125118 REVISED PRESSURE RATINGS - LFS - w v�HORIZONTAL I P.O: Box 230, Valrieo, FL 33595 - O1 Ln NO DATE BY CROSS SECTIONS' Phone_No.: o. 9859.9197• .REVISIONS FBPE C.A. No. 813 ®ZO1 7 R.W.BUILDING CDNBULTAN tB INC. - R.\Clients\Soft-Ute,Pennanent\A-:Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\1`I1-157816TH EO(2017)\FL-15781.15.dwg,3.2 .. co n O O C o C n d o n oo O H T u p n N z O CC Z '^ Z N .o O O .. O m 11/4"MIN. z 1-1/4"MIN. EMB.(TYP.) EMB.(TYP.) Ca CID CID . . a -. n a . . n . . 22 .p Oa - .o o 00 W N e Q N n O O O O a O O Co N Z m 1-1/4 MIN. S EMB.(TYP.) ? 1-1/4"MIN. EMB.(TYP.) ni Go Go n Cd CID . .0 o� . olo o . t— o ' oZa t� . Z O O WN cc N _ . I0CID = m . . N •O - - z - 1-1/4"MIN. 1-1/4"MIN. EMB.(iYP.) EMB.(TYP.) SCHM�� .. - ," . . - .� _ - "`� 'V TVCE1I9Ei'•.�' ice'. - -. Z No.43409 PRODUCT: Documents Pmpared By:���• ,: `� "- _ SOFT-LITE WINDOWS Lyndon F. Schmidt ��'(� ''•...«?!DR •Q;`�` IL4 In o \ P.E. No. 43409" 003 •� r— -1 003 PART OR ASSEMBLY: GD��//BUILDING CONSULTANTS, INC. �l in 1 1125118 REVISED PRESSURE RATINGS. LFS YY P.O. Box 230, VoIrIco. FL 33595 _ Imo. N v NO DATE BY CROSSRSECTIONS Phone No:: 813.659.9197 REVISIONS F'BPE CA No. 9813 ®2017 R.W.BUILDING CCNeIJLTANt3 INC. Ln . V:• 'Qom? ' . . �� c •ems.'; U!m Z �.•Q,ti N o S{myy r���•• • �`~ j 6 M to 7(TYP.): SASH 4+. '�r�4111 'pll` o o m z° r(TYP.) RYP.I. 4°(IYP.) p E 8 a om a m. J• 7 t ` ma o Q. o [W 2X BUCK p 8 3a . v 2X II' 1XCTTK G z II D sucK Ii: TYP. BUCK I I,DIRE O ' II FRAME--" RAME I! MASONRY H 3 11 MASONRY II (TYP.yMASONRY O z OPEN NG !I OPENING ' I I } m ry lI o w II II � m 11. a M -SUCK ANCHORING FRAMEANCHORING z . Ix O CONCRETE ANCHOR NOTES:' a w 1.Concrete.anchorlocations at the comers maybe adjusted to maintain the min. J o . edge distance to mortar Joints. 2:Concrete anchartocotions noted as MAX.ON CENTER must be adjusted to.: a maintain the min.edge distance to mortorjoints,additional concrete anchors a i may be required to ensure the'MAX.ON CENTER"dimension are not exceeded. 3.'Concrete anchor table. N :>::•:>:•;::•;:;::•:>:::;;::»:a:;'':' ....................... ;:;:y;ist'`LNILVtGIRA`RA�IG :i 3MIN CLEARANCE: o ; . .....................:AlVIGJR;>:;:;>:';MIN.;;.r:;;:'>:'::::.............................::::...::.... PP I:I...... 70:MRSONRY:;;:;.; `TO ADJACENT ........_:-::::::• ..:::::::-:::::.:.::::::.:::::::.:::::.::::.-:::::::Et? E:; ;:zi;:• = DAM 10/08/17 a1 1/4" 1.1/4 ijq a o � TAPCON - sr+c- N.T.S. ELCO ,1 J4„ 1•t/4" V 4". 6WG BY. JK 5 m a. tA2RACON ancen LFS. 3 WOOD SCREW INSTALLATION NOTES: DWANG,No.: m 'x• .. n 1.Mafntaln a minimum 5/8"edge distance;1"end distance,&'1"o.c.spacing of FL-t 5781.15 wood screNS to prevent the splitting of vrood: 4 ov 6 0 R\Clients\Sah-Ute Permanent\A,-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017J\FL-1578L15.dwg.S2 O� 1IS � 2.25° 2 86" 1.07" y. p- w ❑ c . 0.067' . ;v o 0.28"- 1.25 0V' {- -�0.386" 18 EVR 3 T11 , i.05'—�! o t�-1.5�►i 0 0.67' C. 0.86" N m I Pal T li C O V .c 17 IJ O+. - 0 y 0.091. o -f-- ..% 0.730" -1.05" No.43409 - * E'k' /•2Q/�t s - c PRODUCT: Oeeumenta,Pmpamd 9Yr. ,� rl� SOFT—LITE WINDOWS P Ed No.F43409 Schmidt 7O4 �` �rtntttrut NA 'RWBUILDING CONSULTANTS, INC. PART OR ASSEMBLY: REVISED PRESSURE RATINGS LFS P.O. Bax 230. Volrieo, Fl.33595 I� v NO DATE gy COMPONENTS Phone No.: 813.659.9197 REVISIONS FT3PE C.A. No. 9813 - '02017 R.W.HUT-64G CCNSU'—t9 INC. BILL OF MATERIALSI''' A 1 X BUCK SG>,0.42 WOOD B 2X BUCK SG>=0.42. WOOD _Z' p C 1/4"MAX.SHIM SPACE D 1/4"X 2-314'PHi ELCO OR!TW CONCRETE SCREW STEEL" :�i•:, Z m . MASONRY-3,000 PSI MIN,CONCRETE CONFORMING TO AC-;I '� }'•. E 301 OR HOLLOW BLOCK CONFORMING TO ASTM"C40 CONCRETE. '�i�� .`� m F #8 iS X 2-1'!2"TRUSS HEAD$MS{S 3/8 MIN.EMBEDMENT} : STEEE �n$fill v a z G T/4"X 3-IX HWH ELC0 OR ITW CONCRETE SCREW STEEL a o c i`4 H 1/4"X 2-3/4"HWH ELCO OR:ITW CONCRETE SCREW: STEEL" e E m ?m o 1 FRAME' PVC " n N g 9 a t n. 3 ' "WEEP HOLE COVER* . PVC' N s ' m °' 4 DSL FRAME FILLER' PVC ;z° 5 DSL HANDLE SASH* a N ' _ : PVC c 1a 6 KEEPER RAIL' 7 LOCK RAIL' . . Pvc 51W GLASS BITE' 718 THICK 8 DSL MAIN SASH" PVC 1/9"ANNEALED ' 9 GLAZING BEAD'" PVC ' 10 DSL COVER': PVC $ �� F 11 ANTILIFTTRACK" PVC Z �- 12' ROLLER SILL TRt. K ALUM. w N. 0 -13 REINFORCEMENT(6065-TS ALUM) ALUM. AIR SPACE J o� lb REINFORCEMENT(6065TS,ALUM)' ALUM. p� �o 15 REINFORCEMENT(60b5TSALUM). ALUM. 1/87ANNEALED 19 ROLLER ASSM. o) 20 LOCK' . 1/2'GLAZING TAPE m 21 LOCK KEEPER STEEL tNTERCEPTSPACER a a LAZING DETAIL"' o: 22 #7 X 3/4"PFH TEK"(LOCK) SS, m 26 #8"X 1"PPHTEK(KEEPER) SS " c 28 WEATHERSTRIP 1187--270 TRI-FIN} H THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY ' a EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". ..' F N to a }_N} K W a z z DATE:I0.08 7 7 i SCALE: N.T.S.' DWG,BY: JK m i UK.BY. LFS. 3 DRAVAND.NO.:. LL'. c - FL-15781.15 O ". SHEET G OF 6 Sep---27 18,05:18p Dash Services 352-596-1182 P.1 L-avres"mie(Mitem LLC Permit&- Licetme Adjuirlistmilon Rn-A791 91),k FL 32873 1993 FmL 407593-9 3 51 Letter Of Cancellation 09)27)2018 To the Aiaemfiosinf Building Department "ll'uritlit Okvacr: Bell,Joni Siic A&xss, 39615 Meadowood Loop ZLp"Ils,FL,33542 fiftrior sathroom Renodiq Please cancel the above referenced permit The homeowner has cancelled their contract for Installation with Loweds and has obtained a refund. As a result, Lowe's has not performed any modification to this property.f do not wish to have open or expired permits on my license. This permit has not been,issued. Thank yop fflr your a s stance in this matter. Puhjri�4010ny CiAbro TU S cc;('i.-PA417 :oirig justrumeni vvus acknowleAgd bc.-bre ine this971h day()r September,201 a rfv C:ffw. M'M-io is per-sonall'y kno-wrt CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20184 BUILDING PERMIT PERMIT-INFORMATION -=:' -�f '- -OCATION INFORMATION =` Permit Number: 20184 Ad'dres : 39615 MEADOWOOD LP Permit Type: ADDITION/ALTERATION / ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL ow ship: Range: gets k: Proposed Use: NOT APPLICABLE ot(o): Block: ion: Square Feet: ubdivision: MEADOWOOD TES Est. Value: arcel Number: 13-26-21-0140- -0870 Improv. Cost: 12,990.00 OWNER INFORMATION Date Issued: ame: BELL, JONI Total Fees: 292.50 Ad ress: 39615 MEA�O OOD LP Amount id: �E-P-H'�(RFjILI FL. 33542 D P. Phone: (813)380-1650 rk Desc: BATH REMODE CONTRACTORS APPLICATION FEES LOW 'S HOME CENTERS INC BUILDING FEE 135.00 ELECTRICAL FEE 67.50 PLUMBING FEE 90.00 Ins ections Required 1v41V -- F OTER 2ND ROUGH PLUMB MISCINSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING 'MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER I st3-7ao•oo2o City of Zephyrhills Permit Application Fax-813-780-0021 I Building Department Date Received I Phone Contact for Permitting 47 ZD 7 — 0 7 5 eeeeeeee � eeee Owner's Name Bell, Joni Owner Phone Number 813-W 1550 Owner's Address 39615 Meadowood Lp.,Zephyrhills,FI.,33542 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 3 6615 Meadowood L ., Ze h rhills, FI., 33542 __] LOT# 0 SUBDIVISION Meadowood Estates I PARCEL ID# 13-26-21-0140-00000-0870 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR 8 ADD/ALT SIGN Q = DEMOLISH INSTALL REPAIR PROPOSED USE �] SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK Interior bathroom remodel-See scope of wort( BUILDING SIZE SO FOOTAGE= HEIGHT •=BUILDING $9,335.00 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $453.00 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ i- 3 172.00 {V � =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY = OTHER ] FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO Z S1 BUILDER I�. ' QMPANY Lowe's Home Centers, LLC I SIGNATURE - REGISTERED I Y/ N FEE CURREN I Y/N Address PO Box 781993,Orlando,R.,32878 e J a, License# CGC1508417 ELECTRICIAN �C'C PA ST MNYV SIGNATURE REGIERED Y/N FEE CURREt Y/N Address 3 Joe Sanchez Rd.,Plant City,FI.,33565 License# EC13005909 PLUMBER C MPANY SIGNATUREWCer., REGISTERED Y/�j .N FEE CURREA Y/N AddressCity,FI.,33566 License# CFC1427710 MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsile,Construction Plans,Slornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsile,Construction Plans,Slormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet.compliance SIGN PERMIT Attach(2)sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. teeeeeeeeeeeeeeeaeeeeelteeeeeeeeeeeeeeeeeeeeeeLlLee UJeeeeeeeereeeeeel Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A(C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 'NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" inrhich may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation und'r state law. If the owner nded contractor are uncertain as to what licensing requirements may apply for the �� inten d work,they ar vtsed to contact the Pasco'County Building Inspection Division—Licensing Section at 727-847- 8009. the owtnevhas hired a contractor or contractors, he is advised to have the contractors) sign po ons of the contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County.Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,600.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify ttiat all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone'v"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensafing volume"Will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. _ If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify,that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing,signs,wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of;six(6)months after the time the work is commenced. An extension may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and Will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU-INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER.. AN ATTORNEY BEFORE RECORDING YOU E OF CO NCEMENT. FLORIDA JURAT(FS.117.03 J OWNER OR ���� CONTRALTO ff b ibed d swom (orafi nedb met7s b 'b d sby 1g m((ora d)bfa this�/ �n �Wh is/ ers9allykntomeleis oras/haveroduced Whoi re ersonally known tome orhasfiav ed s identification. as identification. PublicRotary Public Name of Notary typed,printed or stamped Name of Notary typed,printeLP' = Fog & Notary Public State of Florida blic State of Florida Chad W Berkman Berkman v My Commission GG 171158 ission GG 171158Fxoires 12/2712021 2/2 712 02 1 ~ ' »�� K�����U��"�� �~��^=��U�� K_�°~����°~� K' K������ �� �~o "=�8����� �-KK �� ���� Report [�GWE Project Type: Interiors Customer: Bell, Joni Project Subtype Baths Customer Phone: (813) 380-1650 Storm: 1003 Hoffman, Karen Project ID: 7027183 Print Date: 8/1511810:24AM General Bath Location Main Level Bath Type Master Bath Style Standard Hall Bath Budged $1U.DUD and up Installation Notes: Bath and 1/2 bath remodels with new LVTflooring throughout common areas of house, Hall closet and 2 bedrooms and master closet and kitchen all remain existing flooring. Structural Nubao: Remove accessories|n both bathrooms and patch ond texture where accessories were removed and where vanity countertop side splash was attached. Notes: 'Replace vanities w/top (one isonjoboite already)the other ia8O"vvby 18''dprefabricated vanity with top, REVIEW DATE Toilet Notes: PLANS EXAMINER,�� Replace two toilets that were set aside from demo. R& R same toilets (2). F- Tub/Shower Notes: VV o�n1 |neto| new tub ALL WORK VV���P��\�^|�|�JO�' '~ bat h, ' ' 'and sannentboand 0|aahn��rareow�h12xD4tUa ��OO��FLO��|DA�U|�D|N���OO� ^ ' ' N/�|[]NALELECTR|��CODE Lay|nhodzonbs|offset po� ^enn 8uUnwoe around the ' mindowand onva��o|edging. ORDINANCES ' Page Iof 3 Flooring Notes: In bathrooms(2)remove peel n stick tiles and replace with LVT . Install new LVT flooring in Living room, master bedroom and in hallway. Flooring remains in kitchen, 2 bedrooms and hall closet.Transition from tile to LVT at living room to kitchen transition 117" (9'9").All other transitions(master closet to master bedroom,2 bedrooms to hallway, hall closet to hallway)will all be carpet to LVT. Wall Tile Notes: Millwork Notes: Replace baseboards in newly laid flooring areas(both bathrooms, living room, hallway, master bedroom. Paint Notes: Client will paint. Lighting Notes: Replace 2 wall mount vanity light fixtures. One over each minor in each bathroom. Plumbing Notes: Replace two toilets set aside from demo. Replace two prefab vanities w/tops.Connect supply and drain lines for two prefabricated vanities. Replace shower/tub valve mixer and trim kit in 1 bathroom. Window Treatments Notes: None Electrical Notes: Check for GFCI in bathrooms per code requirement. Page 2 of 3 Other Notes: Hang towel ring and Towel bar in 1/2 bath(aready on jobsite)in 1/2 bath only. Hang two mirrors one in each bathroom(mirrors on jobsite). Page 3 of 3 i8" 43" Bath: Demo Plan: Uninstall toilet and set aside for reinstallation Demo vanity,sink mirror,vanity lop Joni Boll Demo baseboards 39615 Meadow Loop Demo vinyl on floor 2ephyrhiIts.FL 33542 D Replace prefab vanity(on jobsile) 813-380 1650 o In Replace 42 St of LVT on bathroom floor email:jenikbell rQgmail.com �r ri Replace 3 1!4'PFJ baseboards over newly laid LVT t. Replace vanity light fixture(same location) Scope of Work: :h v Replace towel ring and tp holder(on jobsile) Full bathroom: >I i ' Remove toilet and set aside for reinstallation �I. u1111J1/ Demo Plan: IN Demo tubk Demo shower wall the --- Demo vanity,sink mirror,vanity top =!• Demo vinyl on floor l.I I Additional Phoning: Demo vanity Tight(same location) c Demo baseboards in Living room,hallway,master bedroom only(closet remains carpet)flooring and replace with LVl -r Demo flooring In riving room,hallway,master bedroom oprily(dose[remians carpel)replace with LVr Install Plan: to Replace baseboards over newy laid LVT in addtl floored areas(161 LF) O 25" Flooring In 2 bedrooms,master closet,hall closet,kitchen remains as existing flooring. 1 Replace 42 SF of LVT on bathroom floor c in Install one 9'9"tmold LVT transition to kitchen Me- Replace 30' 18'D prefab vanity cabinet 11889757 // u _ All other transitions will be to carpet Replace vanity faucet fixture with drain TOIL.STD Replace 3 1W PFJ baseboards over newly laid LVr Qm i - —r I N Set toile)(set aside from demo) c VB3918346UTT.F Replace alcove tub Replace �- �.' ;- m P N 'I I I I I � . Replace tub and shower valve and fixture II _ L1�:.>• •w J,' , Replace vanity light fixture over vanity Replace shower wall Tile with Future while 12 x 24 to—ceiling Replace 3 x 12 but nose tile on vertical edging of shower(18 LF) includes 1011.waste 6 ±-4 3." 30" YV�25 x Replace Bullnose file around window(12 LF)includes waste 10% ' 16" 31;" 9 96 0 1 t All dimensions_size designations This is an original design and must Designed: 7/26/2018 given are subject to verification on not be released or copied unless Printed:8/15/2018 job site and adjustment to tit job applicable fee has been paid or job conditions. 202 order placed. [cell,Joni All Drawing#: 1 I No Scale. 1 O� ILO IIIUfl Q City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: ���p /� ` ��G�OOlX.f410 Permit Type: Approved w/no comments Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Ka in S er—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) G goo 1 Lowes Home Centers, LLC Permit & License Administration PO Box 781993 Orlando, FL 32878— 1993- Bus. 407/832-8085 Fax. 407/393-9151 AUTHORIZATION 1, Peter Anthony Cafaro III ,hereby authorize the following to sign for and acquire permits and licenses using my State of Florida License No. CGC 1509417 Monica Watson V Craig Watson Sarah Watson Kim Sheldon Kathryn Pemberton Franklin Lake.Pemberton✓ David Mahank- Chad Berkman If you s ould ve an qu stions, lease feel free to contact me at 407-393-9150. Peter A tl ony Cafaro i l l State L'celse Qualifier. Lowe' H me Centers Inc. CGC1 08417 CCC 1 2 824 State f lorida County of Orange The forgoing instrument was acknowledged before me as Peter Anthony Cafaro III,who is personally known to me and who did not take an oath. Swor to ub and subscribed before me this day of 20 o.p is My commission pires Qgparat&, '�'�'�`"y" _ =�,9 NotaryP I M Riccabu"icSta"')+=Inrnoi Karon: y �c MyCommissior7 *-,kjoi �oFflo Expires05128/2D2i ac�ltR^_,Fa,xti,,z_.a_z...� _ ` »�� �����U��~�� �~��^~����b ��^������� �� �� �~o "�«U����� �~� ��� ���� Report ~ FLOWE15 1 Project Type: Interiors Customer: Bell,Jon Project Subtype: Baths Customer Phone: (813)380-1650 Store 1003 Employee: Hoffman, Karen Project ID: 7027183 Print Date: 015M810:24AN General Bath Location Main Level Bath Type Master Bath Style Standard Hall Bath Budget $1D.000 and up Installation Notes: Bath and 1/2 bath remodels with new L\/[flooring throughout common areas of house, Hall closet and 2 bedrooms and master closet and kitchen all remain existing flooring. Structural Notes; Remove accessories|n both bathrooms and patch and texture where accessories were removed and where vanity countertop side splash was attached, Notes. Replace vanities w/top(one isonjobnite already)the other im3O"vvby 18''d prefabricated vanity with top. Toilet REVIEW Replace two toilets that were set aside from demo. R& Notes: CITY OF ZEPHYRHfLLS R same toilets(2). Notes: |n full bath, demo tub and cement board. Install new tub �LLVyQRK SMALL COMPLY WITH PREVAILING and cement board.tile shower area with 12x24tile. �ODBS FLORIDA BUILDING CODE, Lay|n horizontal offset pattern. 8uUnooe around the iqA-1|ONAL ELECTRIC CODE. window and on vertical edging. '�ND � �� THE ZEpHYRNU�S |NANCES Page of 3 Flooring Notes: In bathrooms(2)remove peel n stick tiles and replace with LVT . Install new LVT flooring in Living room, master bedroom and in hallway. Flooring remains in •kitchen, 2 bedrooms and hall closet. Transition from tile to LVT at living room to kitchen transition 117" (9'9").All other transitions (master closet to master bedroom, 2 bedrooms to hallway, hall closet to hallway)will all be carpet to LVT. Wall Tile Notes: Millwork Notes: Replace baseboards in newly laid flooring areas(both bathrooms, living room, hallway, master bedroom. Paint Notes: Client will paint. Lighting Notes: Replace 2 wall mount vanity light fixtures. One over each mirror in each bathroom. Plumbing Notes: Replace two toilets set aside from demo. Replace two prefab vanities w/tops. Connect supply and drain lines for two prefabricated vanities. Replace shower/tub valve mixer and trim kit in 1 bathroom. Window Treatments Notes: None Electrical Notes: Check for GFCI in bathrooms per code requirement. Page 2 of 3 Other Notes: Hang towel ring and Towel bar in 1/2 bath(aready on jobsite)in 112 bath only. Hang two mirrors one In each bathroom(mirrors on jobsite). Page 3 of 3 i 112 Bath: Demo Plan: - -- - Uninstall toilet and set aside for reinstallation --_--- Demo vanity,sink mirror,Vanity lop Joel Bell u Demo baseboards 39615 Meadow Loop I I Demo vinyl on floor ZephyrhilIs.FL 33542 ] Replace prefab vanity(on lobsite) 813-380-1650 c i to Replace 42 St of LVT on bathroom floor j email:ionikbcll@gmaii.com =i� ro ': Replace 3 1/4'PFJ baseboards over newly laid LVT _ r- o Replace vanity light fixture(same location) Scope of Work: _t, I n Replace towel ring and Ip holder(on jobsite) Full bathroom: ( l 1 0 1 Remove toilet and set aside for reinstallation = •: i Demo Plan: �l•—N Demo tubI Demo shower wall the _ Demo vanity.sink mirror.vanity top Demo vinyl on floor (,II I Additional Flooring: Demo vanity light(same location) o L Demo baseboards in Living room,hallway,master bedroom only(closel remains carpel)flooring and replace with LVT m Demo flooring In living room,hallway.master bedroom oprity(closet remians carpel)replace with LVr Install Plan: Replace baseboards over nekvy laid LVr in addd neared areas(161 LF) 1 25"--�I}' Flooring In 2 bedrooms,master closet,hall closet,kitchen remains as existing flooring.Replace 42 SF of LVr on bathroom floor C) m Install one 9'9"tmold LVT transition to kitchen tile. Replace 30" 18"D prefab vanity cabinet#889757 I 1 All other transitions will be to carpel Replace vanity faucet fixture with drain TOIL.STD Replace 3114"PFJ baseboards over newly laid LVT o ' Qm I ,� Set toilet(set aside from demo) VB301834eLJTT.F I ? I Replace alcove tub �1. 4, �)J ro Replace tub drain N `� Replace tub and shower valve and fixture 4 �I 1 Replace vanity light fixture over vanity Replace shower wall tile with Future while 12 x 24 to cer m—'f g Replace 3 x 12 bullnose file on vertical edging of shower(18 LF) I Includes 10%waste 63;" Replace 6ullnose Tile around window(12 LF)includes waste 10'4 16" 31J-49 a" 1 I All dimensions_size designations This is an original design and must Designed: 7/26/2018 given are subject to verification on not be released or copied unless Printed:8/15/2018 job site and adjustment to tit job applicable fee has been paid or job conditions. order placed. ' I Bell,Joni All Drawing#: I I No Scale.