Loading...
HomeMy WebLinkAbout18-20194 CITY OF ZEPHYRHILLS 5335-8TH STREET ` (813)780-0020 20194 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - LOCATION INFORMATION_ Permit#:20194 Issued: 8/30/2018 Address: 3241 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work, 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 226,201.20 Total Fees: 17,565.47 Subdivision: HIDDEN RIVER Amount Paid: 17,565.47 Date Paid: 8/30/2018 Parcel Number: 24-26-21-0100-00000-1250 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,008 SQ FT APPLICATION FEES BUILDING FEE 1,273.49 ELECTRICAL FEE 264.38 PLUMBING FEE 176.25 MECHANICAL FEE 123.38 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections Required FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ORS S'fdNATTL RE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 8x3-780-0020 . , , City ofZeohvrh||b; Permit Application Fax-83-780-002 . ^ Building Department Date Received Owner's Name Lennar Homes, LC Owner Phone Number 813.574.5700 -' ress Owner's Address 4600 FL 33607 Owner Phone Number Fee Simple Titleholder Name I NIA Owner Phone Number . mm Simple Titleholder Address JOB ADDRESS LOT# 11250�����____] ouomm|e|oN Hidden River Phase One A I PaRnsLiD# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW cowsTn AD` LT F--� SIGN �--1 [--� DEMOLISH P INSTALL �_] REPAIR PROPOSED USE eFR �-1 COMM �--� Or*en TYPE OF CONSTRUCTION �uoon F-1 ���m� �--� STEEL [--1 DESCRIPTION oFWORK Single Family Residence Pool/Screen Enclosure/Pence BUILDING SIZE mQ FOOTAGE L���� � VE/onT 7FB~'^-'''~ VALUATION oF TOTAL CONSTRUCTION ��UeLE[xn|CxL [5��l pno8R�oe�wsa�Y �--T vxR�C l�_� AMP SERVICE �= � �-� ' � � ' ��� _ �� VPLUwo|wG ` �� �� ;MECHAN|CAL VALuAT0wOF MECHANICAL|NGTALU�|ON �� [--loAS ROOFING �-) SPECIALTY OTHEROr*sn ��- �-�k F--�. RN|BHEoFLOOR ELEVATIONS FL0Oo�0N�ARE� YsS O DYES | � . omLDsm Z COMPANY I Lennar Homes,LLC SIGNATURE o/ o [_y/ N ] rseounneN L=N Address 14600 Uuonuw# sLsonaoIAm COMPANY =Edmonson Electric, Inc. SIGNATURE REGISTERED pesounns^ Address 11034 Skipper Road,TAKpa, FL 33613 i Uoonua# PLUMBER COMPANY I Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERo FEE ` Address License# MECHANICAL COMPANY [Eay::O::n�et Plumbing, Heating &AC, Inc a|mmxTuRE REGISTERED ��� LY/_N_] rseuunnsN Address Uuensa# OTHER COMPANY o|om4omRE REGISTERED lFEE Address 14211 Shoal Line Blvd, Spring Hill, FL 34607 . Ummae# xumnxumxxunuumoxonnnmxxumxumxxumnxmxxxmxxmmnx � xnnmxxmnxxmononxomoxx RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set m Energy Forms;R�-vv Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus oLife (1)set u(Energy Forms.R-0-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence instal-led, - - Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(q sets m Engineered Plans. °"PnOPERlYGURvsY'requ/md for all NEW construction. - Fill out application completely. Owner&Contractor sign back vf application,notarized n over*cao0,a Notice vf Commencement Isrequired. (wC upgrades over$7aon) ° Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy m contract required) nommmifshingles aammm Service Upgrades /VC renreu(p!ouSurvey/FootaSe) Driveways-Not over Counter ifun public moUvayo..naeduROW NOTICE OF DEED RESTRICTIONS: The undersigned;understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations.; The undersigned assumes responsibility�for compliance with any applicable deed.restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has. hired a contractor or contractors to undertake work, they may be required to!be licensed in accordance with state and local regulations. If the- contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation;Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to,permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department�of Agriculture and Consumer Affairs. If the applicant is someone other than the,"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application.is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management; District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks; Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. understand that the following-restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material -is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. I ' If the fill material is-to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area; I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an enginee eed drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing-construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every,permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.nA 3)OWNER OR AGENTCONTRACTOR J -/,/;j Subscribed and sworn to(or a med)before me this Subscribed and sworn to(or a i ed before-me-this — -- - !0-dur-1--t o by Ashlee Callahan - 13-Jun-1e by Ashlee Callahan Who is/are personally known to me or has1have predused Who is/are personally known to me or hasihave predueed as identification. as identification. Notary Public Notary Public, Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �.I��J4'N,NID6t��lPl' �tl��bkW�t�I�IV:.. - ^�IPtIt1i�A1MNi°Aff�®�7' iE1Rkliadfu�!m,,�p�d I!!�d+�'inarPr�aXFda.�9a9t�fCi�a15,1p11 ,EQ fait illiYN?Ap�WJe:twr�go I#h119,lpil = Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Friday,August 31, 2018 4:25 PM To: Jacqueline Boges; Subject: [Request received]3241 Kresterbrooke lane bp#20194 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/­­requests/237121 ........................ ............ ............ ........................................................... ................... ............ F Jacqueline Boges L-- _J Aug 31, 1 :25 PM MST 3241 kresterbrooke lane bp#201 94 water sewer This email is a service from City of Zephyrhills Support i to City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: l Ynkx-�,(4) Permit Type: 2,00 5 Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ IAWlee � This comment sheet shall be kept with the permit and/or plans. Kalvin S itze`r— ans Examiner Date Co acto and/or Homeowner (Required when comments are present) Jacqueline Boges From: Pamela M. Walton <pwalton@pascocountyfl.net> Sent: Thursday,August 30, 2018 3:11 PM To: Vicki Lewis(viewis@pascopa.com) Cc: Christopher Smith (Christopher.Smith@Lo,onar.com); Jacqueline Boges Subject: Parcel ID Error Vicki, For the highlighted parcel below, it appears that the section and township numbers are reversed. 0 L'ennar Homes-3241 Kresterbrooke Lane 2,008 sq ft SQ. FEET PRICE MAIN OR LIVING: 2,008 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 226,201.20 FEE SHEET $ 1,175.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,273.50 ELECTRICAL: $ 264.38 PLUMBING: $ 176.25 MECHANICAL: $ 123.38 SUB-TOTAL $ 1,837.50 TOTAL $ 1,837.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:j $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL 6,964.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: 17,565.47 Lennar Homes-3241 Kresterbrooke Ln:2,008 sqft Column El SQ. FEET PRICE MAIN OR LIVING: 2,008 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 226,201.20 FEE SHEET $ 1,175.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,278.50 ELECTRICAL: $ 264.38 PLUMBING: $ 176.25 MECHANICAL: $ 123.38 SUB-TOTAL $ 1,842.50 Public Fee 1% TOTAL $ 1,842.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,969.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,570.47 Single Family.Dwelling Pl an Review Comments 1: F.F.E. shall be a.mmimum:00" above the road elevation and an-engineered site plan. 2.. Lots shall be graded.to.comply with R401.3 of the F.B:C. .. : - 3. :Compaction test required if 24" or more of fill dirt is brought in at any one place: 4:. :Tie in survey required before pouring concrete. . . 5.. Drivewaysrequire a R.O.W. use permit:. All sides of driveway thru the sidewalk shall have, - :expansion matenal:. 6.. All setbacks shall be met.: . 7.: All property:markers shall be 'uncovered and'marked at time of first 'inspection: 8:- :All A.D.A. requirements shall"be met.:. , 9.: No.electric;plumbing,mechanical, or Training shall be covered without an:inspection and approval first., 1 O. A11.Gara es shall:com 1_ _.with:section R302:6.of the:F.B.C.: (Fire Separation . 11.Appliances:shall'not:be installed in:-a location where subjectto.mechanical damage unless protectedby approved barriers. M303.4-of-the F.B:C 12. Water heaters shall comply with section.P607,3 of the F.B.C: 13. Foundation supports for."A/C units.shall be raised at least 3". above finished grade,. M1308.1. 14._'Return aifin all-bedrooms. F.B.C. ,M,1620:4 - - . 15:"Smoke detectors are.to be installed:in accordance:withi R313:.1.of the:F.B-.C. 16::Ail glazing requirements are..to be in accordance with R308.4.of the F.B:C. 17. All means.of egress are to be in.accordance with R31 l of the F.B.C., 18. `.`Green gypsum board" shall not be used:as.a-backer.in:sho'w' ortubs. R702.4.2:F.B.C. 19_'Combination-type AFCI breakers'are_required:at all 1ocations-requiring.an AFCI_type breaker: 20: Carbon monoxide alarms will.be required in new:construction-that uses-fossil-burningheating or appliances or an attached garage.. They shall be installed in accordance with the F.B.C. .21. All plumbing,mechanical,:and-electrical shaltbe separate from-unit to unit. This4ncludes all : underground'plurnbin and electric: 22. All 2016.NI C. Codes:will:be enforced.. . 23:Tamper= Resistant Receptacles 1n-accordance with 406.11 of the 2016 N.E:C .24::In aecordance:.With the Land.Development.Code,:lots shall be go'odded before final at least 10. . feet around:the structure.:. 25. Blower_door test and blown in insulation card shall be provided before C.O. 26.A copymofthe energy edcls shall be with permit.at all tinier -.27.. Copy of final insulation report shall be provided wi&permit before FnaL. F:F:E.-Finished Floor Elevation F.B.C=Florida Building Code 6h Edition R:O.W.-Right of Way A.D.A.-Americans.with.Disabilities Act' N.E.C. National Electric Code(2011) 2018147350 Rcpt.:1986282 IT: 10.00 DS: 0.00 Clerk 00 08/29/2018 C. F. , DptY. PAULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER 08/29/20 OR BK 1 m PG '1 Permit No. Parcel ID No 26-24-21-0100-00000-1250 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 125 Street Address: 3241 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: ` N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signa ure of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 13 day of March ,by w Steve Robert Smith as Vice President (type of autho' stee,attorney in fact)for Lennar Homes. LLC (name of party on be alf whom" ment was executed). Personally Known a OR Produced Identification❑ Notary Sign ture Type of Identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ELISSAM.HOLLERAN Signature of Natural Person Signing 9 Above COMMISSIon#FF 985637 � o'=Ex'IresJune 8,2020 wpdata/bcs/bcs form: "'lid , B6nded7hiuTroyFolnlMunncetoe3*7nolp Lennar Homes-3241 Kresterbrooke Lane 2,008 sq ft Column ts / SQ. FEET PRICE MAIN OR LIVING: 2,008 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 226,201.20 FEE SHEET $ 1,175.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,273.50 ELECTRICAL: $ 264.38 PLUMBING: $ 176.25 MECHANICAL: $ 123.38 SUB-TOTALl $ 1,837.50 TOTAL $ 1,837.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% .$ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,964.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,565.47 Ff EL lo 7423 A 127 UL L A AN z FAt 126 'A jr— i9l . • I I !o M.. . r--T-7— Af. 44:0 PH I 'M 100 ANUM L A rk lu j I FFM. I Lu 33 1 FFEL 124 �i A . L k- i FF KL 73M .34 1 WEL A FFF m: 102 123 72M \Masi A EZ I -—————————— A 35 FFEL Mu)o 11.2 A A 7, L AL lsv 36 Ff=r- -. F—Fr-a i 104 L A!5Z FF EL 8 rFF r7;L AN 37 FF P.L 72M 106 -120- A f A A r—FFEL I A A 8 ML 106 A _166 A FF EL I FF EL A I nm -80 INS, A 118 I- t FFr;L 07 72,75 72M Jo 10 A W_ Ile ;.o MID MAC/ N 166 79 FFM_ 7 M ___1 FFM_ 110 FFF9L. I / A ol Now MWAL X, ATC -VD" SHE SCALE lWay-Hom AS NOT ED and ksoclistes, Inc. far-swim Nf 59 HIDDEN RIVER SUB[ -HORN AND ASSOCIATES, NC. BY 042 ZEPHYRKILS, fLCMDA _35 -04130 FAX (81,J) -782-497P. CKMED BY MORNMOM CA =000525 CLC C17Y OF ZLE"'PHYPHILLS R EL, A Alto 7"_EL I Lu LL ffA 0- PASCO COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name 4r Control#' County Parcel No. (� SubDiv: (; Address/Location J� 2, / 6Vt'�` braky Classificatlon/Type of Use �S �p �,r•,,1!�i i� TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: ��17 Exempt []Yes ❑ No How Determined Impact Fee Amount $. 3, Z Cb Zone No. TAZ: SCHOOL IMPACT FEE C�q Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [] Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total i. Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By 4 Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. i DATE RECEIVED BY RECEIPT NO. DATE BY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551131 sf ADS Carrier Builder Name: Lennar Homes 0125 Street: 3241 Kresterbrooke Lane Permit Office: City of Zep h�yirhills City,State,Zip: ,FL, Permit Number:�tCf(�i Owner. Lennar Homes Jurisdiction: el I�O� Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.322 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.96 PASS Total Baseline Loads: 50.93 I hereby certify that the plans and specifications covered by Review of the plans and `_tk1E`Sx�q?,.. this calculation are in compliance with the Florida Energy specifications covered by this 'Qp Code. calculation indicates compliance + �aVeGal>'tGGt with the Florida Energy Code. PREPARED BY: Before construction is completed - -. DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. 'Al with the Florida Energy Code. / � OWNER/AGENT: '� BUILDING OFFICIAL: DATE: 17 It DATE: - Compliance requires certification by Je air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 7/25/2018 9:23 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0125 Project Name: 1551131 sf ADS Carrier Builder Name: Lennar Homes Street: 3241 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.322 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation• R=0.0 1555.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.96 PASS Total Baseline Loads: 50.93 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this leo Code. calculation indicates compliance �,, ''� `'=z�:��. + with the Florida Energy Code. PREPARED BY: Dale A1.01pich Before construction is completed94 DATE: this building will be inspected for compliance with Section 553.908herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9, 9 P with the Florida Energy Code. OWNER/AGENT: BUILDING OFFJCIAI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 7/25/2018 9:23 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0125 Project Name: 1551 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3241 Kresterbrooke Lane Permit office: City of ZephyrhiRs City,State,Zip: FL, Permit Number: 'Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor. Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.322 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 EF:0.950 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.96 PASS Total Baseline Loads: 50.93 I hereby certify that the plans and specifications covered by Review of the plans and -'T1 S7. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance Dave �G� with the Florida Energy Code. D PREPARED BY: A Before construction is completed rid DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building g compliance as designed, is in liance Florida Statutes. !� with the Florida EnergyCode. p OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 7/25/2018 9:23 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 r FORM R405-2017 , INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1551131 sf ADS Carrier Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1555 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1555 12440 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 134 ft 0 1555 ft2 -__ 0.3 0 0.7 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1684 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1555 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1555 ft2 0.11 Wood 7/25/2018 9:23 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM-R4054017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 432.0 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 4 W=>NW Exterior Concrete-Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0 5 N=>NE Garage Frame-Wood Main 11 19 8 8 157.3 ft2 0.23 0.01 0 _ 6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ft2 0.23 0.01 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 1 ft 0 in 4 ft 2 in Drapes/blinds None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 408 ft2 408 ft2 40 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1451.3 79.68 149.84 .2649 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 7/25/2018 9:23 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 4 r ' FORM R405-2017 . INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 311 ft2 Main 77.8 ft2 Proposed Qn Main —cfm 62.2 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May X Jun Jul rj Au Se Oct [ ]Nov ]Dec Heatin HJan Feb f X�Mar Apr May f Jun Jul AuSep Oct [X]Nov X]Dec Ventin Jan Feb X Mar [X]A r Ma [ Jun Jul Aug Se [X Oct [X]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68, 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 7/25/2018 9:23 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13.Cooling system: Capacity 24.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1555 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.556 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.322 14.Heating system: Capacity 24.0 c)Area 7c. 104.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9.00 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 fl Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 07/25/18 Address of New H 3241 Kresterbrooke Lane City/FL Zip: , FL Ze-12hyriUs,FL 33540 7/25/2018 9:24:52 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 BuildingAnalysis Job: 1551B1 sf ADS.Carrier Y Date: 7/2512018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: ` 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.6 6121 28.1 Duds Glazing 30.2 3154 14.5 wait nfiltration Doors 23.5 480 2.2 Ceilings 1.3 1950 8.9 Floors 3.7 5815 26.7 Infiltration 1.9 2372 10.9 Ducts 1901 8.7 Floors Hlumidification 0 0 Glazing Ventilation 0 0 Doors Ceilings Adjustments 0 Total 21794 100.0 • • Component Btuh/ft2 Btuh % of load Walls 2.8 3045 16.4 Wall Glazing 59.1 6172 33.3 Internal Gains Doors 18.4 376 2.0 Ceilings 1.7 2697 14.5 Floors 0 0 0 Infiltration 0.4 531 2.9 Ducts Ducts 2200 11.9 Ventilation 0 0 Internal gains 3520 19.0 Glazing Infiltration Blower 0 0 Adjustments 0 Ceilings Total 18540 100.0 Doors Latent Cooling Load=2292 Btuh Overall U-value= 0.103 Btuh/ft2-°F Data entries checked. -Fk- =ightsoft- 2018-Jul-25 09:22:33 ^�^•t Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCX ..equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: E Project Summary Job: 1551B1 sf ADS Carrier J ry Date: 7/25/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19893 Btuh Structure 16340 Btuh Ducts 1901 Btuh Ducts 2200 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21794 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18540 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1902 Btuh Ducts 390 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1555 1555 Equipment latent load 2292 Btuh Volume(ft') 12700 12700 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 20832 Btuh Equiv.AVF (cfm) 55 30 Req. total capacity at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 470F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 30 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fk- wrightsoft, 2018-Jul-25 09:22:33 Right-Suite®Universal 2018 18.0.16 RSU05714 Pagel '�� ...equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 1551B1 sf ADS Carrier Date: 7/25/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: ' 91.3°F Sensible gain: 18540 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2292 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 20832 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 110% of load Latent capacity: 3600 Btuh 157% of load Total capacity: 24000 Btuh 115% of load SHR: 85% Heating Equipment, Design Conditions Outdoor design DB: 30.8°F Heat loss: 21794 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18304 Btuh 84% of load Capacity balance: 30 °F Supplemental heat required: 3490 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 800 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. - wrightsoft® 2018-Jul-25 09:22:33 �. •w��ate•=w -,�m�� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCK ...equipment\1551 sf ADS template 2ton Cartier.rup Calc=MJ8 Front Door faces: E Ly Lis FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Emi-e-lope Leakage Test Report and Performance Method Priojea Narne.- I. Builder Name: L&Ut_zq S- 9,;2 9//' Permit Office: ffkly"m S Permit Number Siasizn ZE'Aw"11-I L Jurisdiction: SQU=r=- Feez Conditioned Volume: 10?t1y6) Envelope Leakage Test Results Single Point Tom, D_a�-: HOUSE PEES SL'RE: - Q FLOW: q Leakage Characteristics [?/Pass FFail C-FM, ,5 j — R402.4.1.2 Testing. zuidrc zr=,keiirc_rir S.—al ze amzvenfiec�as having an air lea.,Nage rate of not exceeding 7 air --e- -o-r r �_-ir-z2e Z::r,--,z T arc- z 7---strc :e =rcuc.,�± wf_i a blower door at a pressure of 0.2 inches w.g. (50 �Bsm*': --amr-c s-al --e :_-n:u:, rd--,,cLzs% aa _t red it Sectcr, 52: c3k ) or (7). Florida Statutes or ilze-se!: as S-:* 0 r Sea­cr -LE: _c., zr -Lird par., A writter, report of the results of the test shall be a-c :r--,,cez - cccce cff..c.ei. Tesllrc s^all ce cenbrTned at any time after creation of all wr-ozas---n=--r-'r-s Irsciace_-a-c st=. *e--Ccrz-Sral ce C-c-se-c. ZU't nct sealed.teyond the intended weatherstripping or other ri::uj= 3k7a_zr_ 7= —=4�_:c ar ackj aft andzadamselsrs snw ze desed. but net sealed be.. nd intended i-7te--cr 37o-s f r-_-zaleruz a:7e:r-,-=Zz':'C-� Sr-al =e Cce :c sealed: .crs- CZ cicsed and sn: --n-nirt; a-,�_E tr-e:ft.re=—z-, :al :e t-T-ec and S-cce. S-1:-e::-- rsm I--Z 7-____r c es:. N cce- V-1--_ at. Where required by the code official. testing shall be - .7 with 1 conducted by an approved third-party. A witten report of Fionw-4a E-)snun, 7eq- wit�-, the test results shall be signed by the third Party conducting the test and provided to the Code official. SIGNATURE: 'erS PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: f ®R4 A%zz. '7n 1 7, r=.t;Aznh=1 am-AMV 1N'%1Q •p . PPF7 Florida Building Code Duct Leakage Results Builder: Neighborhood: &1,_79si�-i Rlas;e Lot#: /A S_ Address: City: 2�1dr�1�2►>�«�5 State: PL- 33S''FG Permit#: Square Footage: Stage of Construction for Test Rough in with Air Handler Rough in no Air Handler Post Construction Duct Leakage Test Results: Duct Leakage percent requirement: % System CFM25 Square Duct Leakage Location Pass or Fail Footage CFM/100s ft. � `�• t 5 SS' �-g � /�.,./tJ� firs S 2 3 4 5 E:� Pass Fail Rating Company: SkYeTec® Inspection Date: Rater Name: Thomas K. Peters Rater Signature: >''-�%��► � 17�'�� 0 The Energy Code Experts 9570 Regency Square Blvd.Suite 410 Jacksonville, FL 32225 Phone:904.482.4000 1 1.866.SKYETEC www.SkyeTec.com 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3241 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL,33607 Parcel: 24-26-21-0100-00000-1250 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ sprinklers Use Classification: NOT APPLICABLE Permit Number: 20194 Date: /1X1/2018 ISSUED BY:\- BUILDI{OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE