Loading...
HomeMy WebLinkAbout18-20404 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20404 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20404 Issued: 10/31/2018 Address: 3316 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total Fees: 17,872.97 Subdivision: HIDDEN RIVER Amount Paid: 17,872.97 Date Paid: 10/31/2018 Parcel Number: 24-26-21-0100-00000-0930 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT APPLICATION FEES BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00 MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 /ks_',LU i InspeWtions Re uired FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS-SIGNATURE PERMIT OFFI PERMIT EXPIRES IN MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received SE 13 2018 phone Contact for Permitting 813 363 __ 2891 dingJLJ� Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address I N/A JOB ADDRESS 3316 Kresterbrooke Lane LOT# 0930 SUBDIVISION Hidden River Phase One B PARCEL ID# 24-26-21-0100-00000-0930 ,�� (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ II NEW CONSTR E ADD/ALT SIGN Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR COMM OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL 0 DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2376 SQ FOOTAGE 1936 HEIGHT 1 Story � BUILDING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ ®AMP SERVICE PROGRESSENERGY 0 W.R.E.C. �• r PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION OGAS ROOFING 0 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA RYES Do BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Ly/N Address 4600 W. ress St.Ste.20 ,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skip Road,T a, FL 33613 License# I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 018, Bay et, FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 53 , Bayone , L 34674-5308 License# CAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4211 Shoal Lin Ivd, Spring Hill, FL 34607 License# CCCO57991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ■ . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW - NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subjdct to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six-(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTO BEFORE RECORDING YOUR NOTICE O C NCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirm before me this Subscribed and sworn to(or ed)before me this i U-oep-10 by As lee CaHah 10-sep.18 by Ashlee ahan Who is/are personally known to me or hasihave PFGdu^��' Who is/are personally kno n to me or has/have predue s i tification. as identification. Notary Public Notary Public ommission No. FF98537 Commissi o. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped •�1���.1�9UtEi�1#W' . ��rcrr4s'anii�.ppnlaa��' Lennar Homes-3316 Kresterbrooke Dr-2,376 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,145.00 TOTAL $ 2,145.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,272.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,872.97 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Thursday, November 1, 2018 4:42 PM To: Jacqueline Boges Subject: [Request received] 3316 Kresterbrooke Lane by#20404 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/248616 ....................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Nov 1 , 1 :41 PM MST services 3316 Kresterbrooke Lane by#20404 water, sewer , water meter This email is a service from City of Zephyrhills Support . 1 FLU#31 u fly City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ku,MW Date Received: f Site: 3 3( Permit Type: Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or pl s. Nib, Kalvin Switzer—Plans Examiner Date Contractor an or Homeowner (Required when comments are present) I I��II�IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIIIIIII IIII 2018182158 Rcpt 2901351 —Rec: - DS: 0.00 IT: 0.00 10/26/2018 L. S. , Dpty Clerk PAUL-9-$.-O-NEIL,-PF.0. gSCO CLERK& 10 COMPTROLLEh %R6BK 1980m PG of 1 753 Permit No. Parcel ID No 24-26-21-0100-00000-0930 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 93 Street Address: 3316 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St, Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (if other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: :.:.:.` : N/A Name Address city State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by ` Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA � COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 10 day of September by Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes, LLC (name of party ehalf instrument was executed). Personally Known I OR Produced Identification[INotary Signature Type of Identification Produced Name( is Sa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. = f( s ELISSAM.HOLLERAN" . Signature of Natural Person Signing Above 13eroln1ee10n#FF OM637 EXPROS June 0,2020 wpdata/bcs/bcsform; 'BondeiThm7royFolnlMunncelODai5dOto l S?A.TE OP FLORIDA, COUNTY OF PASCO THiS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE ` � o 41 WIT MY HAND AND OFFIC SEAL THIS G t}I� . o".. DAY 2� }4 rii-ilPAULA S.O' I LERK&COMPTROLLER 188F �',8�d BY DEPUTY CLERIC PASC O COUNTY, FLORIDA Permit No. 2-6't� / Date Permitted ,-I ct- L 2 —( Builder Name/Owner Name &Ap,- es Control County Parcel No. 01 DO- a ^d`�30 SubDiv: �12ctctc ` Address/Location 3 f d -+ A Classification/Type of Use St, TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2.-13-1 Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. 3r6�2�60 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ a, j 99. 2$ (057) Mpbile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ ir2�S,6 Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By � Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes 3316 Kresterbrooke Ln-2,376 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2;376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 I BUILDING: $ 1,487.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,150.00 Public Fee 1% TOTAL $ 2,150.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,277.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,877.97 KETCH PLOT PLAN NOT ASB UND RYLSURVEY SEC. 24 TWP. 26 S, RNG. 21 E. LOT 9 3 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS 1 MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 8116.22 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = ----SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =_40-_SQ. FT. r�i UNDERGROUND FOOTER, STEM WALL, AND GARAGE =_407 _SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI = N-A SQ. FT. SHOWN. = PROPOSED DRAINAGE FLOW PATIO =-23---SQ. FT. (00.00) = PROPOSED GRADE CONC. DRIVE =-475 --SQ. FT. w DO NOT SCALE THIS PRINT. DIMENSIONS AND E-00.00 = EXISTING GRADE A/C & CONC PAD = 9 __SQ. FT. _j NOTES TAKE PREFERENCE. PRIVATE SIDEWALK =29----SO. FT. N DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: IMPERVIOUS = 31_ 2539 Q. FT. PAGE INDICATES THAT PLAT IS IN —S LOT GRADING TYPE = A PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION = SOD =-557_7_—SQ. FT. CHANGE AND/OR REVISION. FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS = 10' � CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK REAR SETBACK = RIGHT OF WAY = 2264.52 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON =_144_—SQ. FT. PUBLIC SIDEWALK =_710 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES SOD =-1411 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. TOTALS ► = 10' DRAINAGE/UTILITY EASEMENT AREA = 10380.74 SQ. FT. DRIVEWAY =-619 `SQ. FT. SIDEWALK = 739 SQ. FT. SOD =-6988___SQ. FT. DAWSON CHASE DRIVE HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) (50'R/W) o. PLAT W BOUNDARY Z I 'S 89'40'43" E 85.03%,,'.': . �w^ d,?SJ. PRM(P) zj /-M- - - - - - - - - - -o - - - - (TYP) W O^ M o: ui: Yw N N: ¢w� � O Oal. ....... .........' A/cE1: 6 0 w^,o I rjS 20150' .......24.50'....... t` 65--0" �wpv RAJI O • �om .....20'50•..... o - w N Lil=� * 28.33' oz�mLJ= rn o O w ........�.......... n gm��c� o of o o a= N w c9 � � o W 1 r ' z O O O . o I� r,1 ,? :.. I.:": ..'... '�: :^ LOT 324 N' ' HIDDEN RIVER PHASE ONE A O +. .•f N 89'36'58'W 24.50' (PLAT BOOK 74, PAGES 101-121) ........ ......... ..................... 29.67 ry ;0 2 . o' r�� .- �"^^' N 89'40'43" W 1 10.00''�"'v f�nn �q, Srj SS• - J. PLAT BOUNDARY T Q BOIJDARY LOT 92 N O '-1 Oi W '-1 O PROPOSED: DESCRIPTION* LOWEST FLOOR ELEVATIONS: 3 LIVING AREA: 74.90' o LOT 93, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", GARAGE AREA: 74.36' F AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, ELEVATIONS REFERENCED TO m OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. NATIONAL GEODETIC VERTICAL lb z CURVE RADIUS ARC CHORD BEARING DELTA DATUM OF 1929. MEAN SEA 'L ui C18 25.00- 39.24- 35.34• N 45'21.10'• E 1 89-56.15" 1 LEVEL= 00.00 FT. ul Q a APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30 1992 Project Number: Squrea Feet: 8116.22 t LENNAR HOMES z LEGEND: o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q.= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, 2 F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, m U P= UTILITY POLE W F= WOOD FENCE n JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS a SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JRB a, ONE OLDSMAR, FLORIDA 34677 v WAY (813) 854-1276 FAX (813) 855-8370 Scale: QQ NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 8/16/18 ACS 0 o THE ORIGINAL RAISED SEAL OF A FLORIDA SIGNATVNl D TE •5' LICENSED SURVEYOR AND MAPPER JOH BEA Revisions: FL VI REG. D SURVEYOR No. 2984 LB 4493 J F M. HARTL LL P URVEYOR & MAPPER No.7123 W�- p �C_�, - .... _ I1 1 - _ C2 } ETEM KE 9 �. ....... . .................... .... ............. , P I V�l aA B Jco co �.. 8, t � .. f ' I = I { � I ° - ' •{ ; . .... 1 I I t 1. t I B 3 j ,� � . � �' � � -•- �-- I B -i t t { � I :{ k t E 3 I { I I I B 11 I � l� � �4- - - I I 1 t t { I R . "-.- t R I r I t I I ( t I t - f t-• t B —� t { � ..�._ pA :.;.. w _.._ .............. HALL € r � 11 � RB d 11 f B 1 g @ 1 I R - � <.a • f 1 ! I .. '� t { � -t I _16 t� I 'l CO CD Olt - . G m ro I'-"I ba Se F Sing an�h :Y Dwe ing P h Review Comments 1: F.F.E. shall'be above.ther vn and' n an engineered site plan. - 2. Lots-shall be graded to.comply with R401.3 of the F.B:.C. . 3. Compaction:test required if24" or more of fill dirt is.brought-in at any one place. 4: Tie in survey-required before pouring concrete. 5. Driveways.require a R.O:W.use permit:' All•4 sides of driveway.thru the sidewalk shall have. , . _ expansion material: 6. All setbacks shall be met.. . 7. Ali property: ' arkers shall be.uricovered and marked at time of first-ins pection: . . 8: All A.D.A. requirements shall be met.: . 9. No electric;plumbing, mechanical,.or lfraffiina shall be covered without an inspection•arid approval first. . 10. All Garages shall:comply with section R302.6-of the F.B.C:, (Fire Separation). 11: Appliances shall not:be installed iri a location where subject to_mechanical damage unless proteded.by approved barriers. M303.4 of the F.B:C 12. Water_heaters shall comply with section P607,3 of the F.B.C.* 13. Foundation supports for.A/C units shall be raised at least 3'.' above finished grade. M1308.1 14. Return air in all-bedrooms. F.B.C. M.1620.4 15. Smoke detectors are to be installed:in accordance with R313:1 of the:E.B.C. M. All glazing..r u. .r.r. ements are:to be in accordance with R308.4.of the F.B:C. . 17. All means of egress are to be in accordance with R311:of the RB.C.. 18. "Green gypsum.board shall not be used:as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI•breakers are required-at all_locations requiring an AFCI.type breaker: 20. Carbon monoxide alarins:will be required in new:construction that uses-fossil-burning-heating, or appliances of' attached garage. They shall-lie_installed in accordance with the F.B.C. 21. All plumbing, mechanical,:and electrical shall:be separate from unit to unit: 1This-includes all. . underground plumbing and electric: 22. All 2016.N.E.C. Codes will be enforced. .23. Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C . 24.1h accordance with the Land.Development.Code, lots shall be sodded before final at least 10 . feet around the structure. 25. Blower door test and blown in insulation card shall be provided before C.D. 26 A copy of the energy cacls.shall be with permitt at all tines. 2Z. Copy of final insulation-i'eport shall be:provided fvith:permit before,final, . 28. No fence:pool onscreen enclosure is.issued with this perntiz F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W.-Right of Way. - A.D.A.-Americans with Disabilities-Act N.E.C.-:National Electric Code(2016) 24-26-21-0100-00000-0930 j Pasco County Property Appraiser Yage 1 of 1 Data Current as Of: Weekly Archive - Saturday, October 27, 2018 Parcel ID 24-26-21-0100-00000-0930 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $28,904 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3316 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 Just Value $28,904 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,904 HIDDEN RIVER PHASE ONE B PB 76 PG077 9 LOT3 Taxable Value $28,904 OR 9799 PG 708 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use — — Description!ZoningUnits Typev _!Pace ;Condition ;Value _ - 1 ;_0100 __ SFR _ _; MPUD j 6,000.00 SF 4.50 1.00 ; $27,000 2 0100 SFR j MPUD 2,116.00 1 SF j $0.90 1.00 1 $1,904 Additional Land_Information Acres 1 0.19 Tax Area] 30ZH I FEMA� Residential Code HDRVLPI j { Code I I -- �-------------- Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line_-- _ `_ -1Description _ �Y, ear -_T_jUnits --_`--, �Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year_ _ Book/Page Type _ _ D_OR Code Condition mount nt 10/2018_ - 9799 / 0708 j--Warranty Deed i 05 Vacant Multi-Parcel Sale 09/2011 8606 / 3376 I- Warranty Deed — 05 _ Vacant i Multi-Parcel Sale- 06/2010 18360 / 1872 I Certificate of Title 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000000930 10/29/2018 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes 0093 Street: 3316 Kresterbrooke Lane Permit Office: City JZephyrhills City,State,Zip: FL, Permit Numbeg Owner: Lennar Homes Jurisdiction: Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5: Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7..Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 309.76 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=b.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:_40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS Total Baseline Loads: 62.90 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliancewith the Florida Energy Code. ti' iwli' PREPARED BY: Dave AUnM Before construction is completed - -" DATE: this building will be inspected for a. 1, compliance with Section 553.908 ,* ° I hereby certify that this building,as designed, 's in compliance Florida Statutes. C, with the Florida Energy Code. OWNER/AGENT: 3 2018 BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qri requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941131 sf ADS Carrier Builder Name: Lennar Homes 0093 Street: 3316 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction:611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1936.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 309.76 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS �+ Total Baseline Loads: ASS 62.90 I hereby certify that the plans and specifications covered by Review of the plans and �ti'QT ST•q?� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave AWch Before construction is completed r DATE: this building will be inspected for 0.�, compliance with Section 553.908 I herebycertify that this building,as de i n , is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. SEP 13 2018 OWNER/AGENT: BUILDING OFFICIAL: DATE: la 1DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). ' - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941131 sf ADS Carrier Builder Name: Lehnar Homes 0093 Street: 3316 Kresterbrooke Lane Permit office: City of Zephyrhills _City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction:611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst.case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area 2 a.Under Attic(Vented) R=30.0 1936.00 ft 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 309.76 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.33 b: U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS Total Baseline Loads: 62.90 I hereby certify that the plans and specifications covered by Review of the plans and DKE S7•q?� ` this calculation are in compliance with the Florida Energy specifications covered by this 0' Code. calculation indicates compliance /. with the Florida Energy Code. PREPARED BY: Dave �{�Ol�lM Before construction is completed r '' DATE: this building will be inspected for O compliance with Section 553.908 I hereby certify that this building,as desi ed, is in compliance Florida Statutes. with the Florida Energy Code. CpD yyE 1'�� OWNER/AGENT: SEP 2a�9 BUILDING OFFI DATE: DATE: ®� - Compliance requires certi elation by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in cordance with R403.3.2.1. -Compliance requires an A Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, , tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page.1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1941 B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 - Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished- Cooled Heated 1 master 210 1680 No 2 1 1 Yes Yes Yes 2 family rm 341 3171.3 No 0 1 Yes Yes Yes. 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 e__ 0 0 1 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 0 0 1 i 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 ___ 0 0 1 4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 1 0 0 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 e__ 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 -__ 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 -___ 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 1 0 0 11Slab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 e__ 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft . 0 100 ft2 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 _ Wood 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Ahhip Space CavitR_Vaty Width Height Sheathing Framing Solar Below -Vpp 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ftZ 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ftZ 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 Q.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ftZ 0 0 0.6 0 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ftZ 0 0 0.6 0 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ftZ 0 0 0.6 0 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ftZ 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ftZ 0 0.23 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ftZ 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ftZ 0 0 0.6 0 16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.23 0.01 0 _17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ftZ 0 0 0.6 0 _18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 .0 0.23 0.01 0 _19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0 20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang - V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>SW 1 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1-ft 0 in Oft 11 in None None 2 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 46.0 ft2 1 ft 0 in 0 ft 11 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 8 in None None 4 E=>SE 7 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in Oft 11 in None None 5 E=>SE 8 Metal Low-E Double Yes 0.54 0.33 N 16.0 ftZ 1 ft 0 in Oft 11 in None None 6 N=>NE 10 Metal Low-E Double Yes 0.56 0.3 N 23.0 ftZ 1 ft 0 in Oft 11 in None None 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017' INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft2 416ft2 43.7ft -8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000376 1908.7 104.79 197.06 .2844 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— --Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN. RLF Heat Cool 1 Attic 6 309.76 family rm 77.44 ft Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]]Jan [[ ]]Feb [[ ]]Mar ]A r [ ]Ma [[X]]Jun [X]Jul ri Au jXj.,9:PpOct Nov HD ecHeatin [X]Jan [X]Feb [X]Mar ]APr [ ]May [ ]Jun [ ]Jul Au S [ ]Oct N Nov DecVentin [[ ]]Jan [[ �)Feb [[XX]]Mar ]A r [ ]Ma [[ ]]Jun [ ]Jul Aug Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft, Oft 0.3 Main Default(8 Ibs/s .ft. 0 ftz 0 ft 0.3 Casita with Bonus Name: Signature: Rating Compant: Date: 7/26/2018 12:37 PM EnergyGauge®'USA Section R405.4.1 Compliant Software Page 6 of 6 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic/family rm 3. No.of units(if multiple-family) 3. 1 4.Number of bedrooms 4. 4 13.Cooling system: Capacity 34.8 a)Split system SEER 15.0 5.Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 1936 d)Room unit/PTAC EER e)Other 7.Windows,type and area a)U-factor:(weighted.average) 7a. 0.551 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14. Heating system: Capacity 34.6 c)Area 7c. 157.3 a)Split system heat pump HSPF 8.5 b)Single package heat pump HSPF 8.Skylights c)Electric resistance COP a)U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1, e)Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 fl Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11 d. No e)Multizone heating credit f)Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 09/10/18 Address of New Home: 3316 Kresterbrooke Lane City/FL Zip: FLZe1_2hyrhi11s, FL 33540 7/26/2018 12:38:37 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Anal Job: 1941BI sf ADS Carrier g Y$IS Date: 8/13/2018 Entire House By: Dave Bayonet,Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(7) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph)• 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 5.2 8237 28.6 Ducts Glazing 30.2 4709 16.3 walls Doors 23.5 466 1.6 Infiltration Ceilings 1.3 2429 8.4 Floors 3.5 6726 23.3 Infiltration 1.7 3056 10.6 Ducts 3221 11.2 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Other Ceilings Adjustments 0 Total 28843 100.0 Component Btuh/ftz Btuh % of load Walls 2.8 4367 16.7 Walls Glazing 56.7 8852 33.8 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.8 Floors 0 0 0 Infiltration 0.4 684 2.6 Ducts Ducts 3628 13.9 Ventilation 0 0 Internal gains 4900 18.7 Glazing Infiltration Blower 0 0 Adjustments 0 Ceilings Total 26154 100.0 Other Latent Cooling Load=4080 Btuh Overall U-value= 0.102 Btuh/ftZ-°F Data entries checked. -Pk wrightsc t- 2018-Aug-1314:36:54 '_Z_ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 AC(>, ...equipment\1941 sf ADS template 3ton Camerrup Calc=MJ8 Front Door faces: W Project Summary Job: 1941B1 st ADS Carrier 1 ry Date: 811 312 01 8 Entire House By: Dave Bayonet Plumbing Heating and Air Project Inf• • For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 'F Inside db 70 °F Inside db 75 'F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25622 Btuh Structure 22526 Btuh Ducts 3221 Btuh Ducts 3628 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28843 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26154 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3419 Btuh Ducts 660 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1936 193g Equipment latent load 4080 Btuh Volume(ft') 16360 16360 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30234 Btuh Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC536AO0300 Cond 25HBC536AO0300 AHRI ref 9155179 Coil FX4DNF037L AHRI ref 9155179 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 26 °F Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point=28°F Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- 2018-Aug-13 14:36:54 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipmenM941 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 1941B1 sf ADS Carrier Date: 8/13/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26154 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4080 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30234 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29580 Btuh 113% of load Latent capacity: 5220 Btuh 128% of load Total capacity: 34800 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 28843 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26331 Btuh 91% of load Capacity balance: 28 °F Supplemental heat required: 2512 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. -�- wrightsoft® 2018-Aug-13 14:36:54 "� ..• «-»w. Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipment%1941 sf ADS template 3ton Carrier.rup Calc=MJB Front Door faces: W 141 Poe, V% q3 . PASCO COUNTY ��� DEVELOPMENT SERVICES 8731 Citizens Drive Date:2/12/2019 COUNTY FLORIDA� New Port.Richey, FL 34654 Uri:.l:an_u.l4rucrti l t.,�s. TA 727-847--241''1p� �g T A 9 p E i 9�SY N T Receipt M 1830310 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee.Residential Solid 24503100-329010 1.00 1427674 $60.30 $60.30 1830310 2/12/19 Waste Sidjle Family TOTALS: $60.30 $60.30 Receipt# Paid BV Check# CC Auth# Cashier ID Workstation Receipf Date Amt Paid 1830310 Check 1155470 BCCCP59W 02/12/2019 $60.30 Total Payments: $60.30 Pavor Address Phone Lennar Homes, LLC Comments: WIM !�v 3316 Kresterbrooke Lane -- Whlle.you wlll be paying your bill with Pa_sco County Development Services;the full amount of the credit card or a-check fees;NOT shown above;is collected by- - - - Flrst Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6.rpt 2/12/2019 Page 1 of 1 Jet Stredmo Ultra Slowing wool Insulation Attic and Cavity Wall Gard rf! frl�e�O lgve Batts and and Blankets Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with aminimum'/,'internal corrugation,a minimum length recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35 rbslminute.Recommended feed provide Me full R-value, rate is 15-25tbs1minufe. Rail Nola POW111 W attic Ohliml Thesiaiad terfaalresislance(R-value)is VON byias?alligioacudaa eoml he aufv,uresmsbfoons,Failure loiasmme To obtain an � Installed insulation should required number of bags per 1,000 square feel and exceeding the maximum square feel of coverage per bag as recommended by file label insulation resistance a0���iBSS lia3�, 1 RtVnue 011[�s ll1i lo���i�s��ll� OlEi�ldl91I�is�l�uc�d0o fImlilliasula!105isaolrecolaa idedbyihemaaufacturer, C I a { R49 13. 5' R-38HQ 10.25° Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. 38 R-38 12,00' R-Value* Bags per 1000 SF Maximum Not Minimum R-30HQ $.25' To obtain an The number of bags Coverage per Bag Weight per SF ; insulation par 1,000 square feel Contents of this The weight per square R-30 10,00, Cavity resistance of not area should not bag should not feel of installed insulation I` R 26 9 00, Framing Depth of. Density be less than: cover more than: should not be less than: t R-22 6.50' 2"x 4" 3.50" 1 R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft 0.525 tbs. R 21HD 5.50' 2'x 6" 5.50, R-23 1.8 lbsJcu.fL 25.8 bags 38.8 sq.ft. 0.825lbs. i R-19 6.25"'" 2'x 8" 7.25" R-31 1.81bs./cu,ft. 34.0 bags 29.4 sq.ft. 1.088 tbs, I R-15HD 3.50, R-13 3.50' 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. R-11 3.50' R means resistance to heat flow.The hgher the R•vatpe•the greater the insuta*pesser.To get the marked R-value,d is essential that this insulation be Installed properly. R-8 2.50' ^R-18ma5S�avity.Conforms tohSirACB2,50 derai Open Attic Application Bag Net Weight-Nominal 32 tbs.,Minimum 31 lbs. Spe-fcation HH-1.521F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness*" To compensate for training members,the number of bags per The number of bags/ Contents of this The weighlrSF Thickness Contents of this 1,000 sq.ft.of area to be insulated should be as shown below. R-Value" 1,000 SF of net area bag should not of installed Installed insulation bag should Ba SiMSF Sa S(MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more 9 $ resistance(R-Value)of: than: more than: be less than than: than: Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952 tbs. 19,750' 19.750" R-Value Dimensions Framing Framing 2x4 29.2 29.4 R-49 23.5 42.6 SF .753 lbs. 16.375' 16.375' R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 tbs. 14,875, 14.875" 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" 2x4 23.0 23.2 R-30 13.6 78.3 SF .437 tbs. 10.375' 10.375' R-49 2x6 22.7 22.9 t R-26 11.8 85.0 SF .377 lbs. 9.125° 9.125" 2x8 22A 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750' 7.750' 2x4 20.4 20.6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750' 6.750" 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 ibs. 4.750" 4.750' 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 tbs. 4.000' 4.000° R-38 2x6 17.0 17.2 annetvmye"omnaa2t._ursnwms1ks. 2x8 16.7 17.0 cPxage�a nstata mdsa.�eae�ns smeatiwe tctmgretfs a pis gaeog.zor��a�sre�oua�z auemason . � This pd wntmmstothaT +ce requ¢emenhatASTM Glbs,type t aid canceCad Fed-xz specraa5m tat+tD3aB,Type 1,t]ass B.R-rates aro da:amaaad m aamEaxa unh C s$7 eM CStB 2x4 13.2 13,3 ••R'mmdaeans sestVance b Not Ib".Tice hgher the R-vwe,the War me i nadathg poxes To get the mmksd R-ae,it is essential that ruts mswa5on be ur:toted property.Il you do it ywrsalf,get hstnx- R-30 2x6 12.9 13.1 001 srdW-thE wems:"s-ansda'wt -,In INS px'er- "Based on Thal Paly2lex ses:tr.3 study.Mepedded seatemers-a 20 year pemd w,wk be i perwntatass.This amount cs seUgis mamrety irsgrufcans Thenrom the mstaeed end swat 2x8 12.6 12.9 thxWmses ara e8ad sryfiesm e. 2x4 11.3 11.4 vola-rlaX%is a re#---ad oa,!ak at tlriwl. R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream flora has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 26 9.1 9.3 Attic Area R- at Inches 2x8 8.8 9.1 Sloped Ceilings R- at Inches 2x4 7.9 8.1 Walls R- at Inches R-19 26 7.7 7.9 Floors(over an unheated crawl space) R- at Inches 2x8 7.4 7.7 2x4 5.3 5.4 Crawl Space Peri eter 17 R- at Inches R-13 2x6 5.0 5.2 Dato installed 2x8 4.8 5,0 Blow tion has been i tailed in conformance with the above re ca m provide an R-value of 2x4 4-3 4.4 R_ �jj using bags of this insulation to cover square feet of area R-11 2x6 4.1 1 4.3 at a minimum thickness of inches. 2x8 3.8 4.1 Men Buildings TaIg.We Listen FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: -14ORV 7.5 Builder Name: GEAuN.4P2 Street: Permit Office-, City, State,Zip: z eo Permit Number: 20al6q Design Location: Jurisdiction: Square Feet: 15'3e, Conditioned Volume: )63(po Envelope Leakage Test Results Single*Point Test Data: HOUSE PRESSURE: —156 FLOW: 165 11r Leakage Characteristics CFM (50): 2�pass D Fail ACH(50): 27 R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones I and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(T�, (g), or(i) or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. 1. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures-, 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and 6.Supply and return registers, if installed at the time of the test,shall be fully open hereby certify that the above envelope leakage Where required by the code official, testing shall be' )erformance results demonstrate compliance With conducted by an approved third-party. A written report of :lorida Energy Coder quirements in accordance with the 'Lest results shall be signed by the third party ;ection R402.4.1.2. conducting the test and provided to the code official. "IGNATURE: IRINTED NAME BUILDING OFFICIAL: )ATE: DATE: