HomeMy WebLinkAbout18-20407 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20407
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20407 Issued: 10/31/2018 Address: 3052 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 267,656.40 Total Fees: 17,872.97 Subdivision: HIDDEN RIVER
Amount Paid: 17,872.97 Date Paid: 10/31/2018 Parcel Number: 24-26-21-0100-00000-0700
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT
APPLICATION FEES
BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00
MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMP CT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
6 1 C
rS t k Ins ections a uired
F ER 2ND ROUGH PLUMB M16C INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
41 1A (� DJA - &__ fW10
O C ORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Lennar Homes-3052 Moulden Hollow Dr-2,376 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,482.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,145.00
TOTAL $ 2,145.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,272.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,872.97
i
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Thursday, November 1, 2018 4:25 PM
To: Jacqueline Boges
Subject: [Request received] 3052 Moulden Hollow Dr by#20407
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/248608
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
Nov 1 , 1 :24 PM MST
services 3052 Moulden Hollow Dr bp# 20407 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
' � I10f11UH
r �
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: ( �J Site: c� (�J' Z di.C,l�2yt �l/
yc�
J
Permit Type: Z 3?6 S
Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plan .
Kalvin Switzer—Plans Examiner Date tractor and/or Homeowner
(Required when comments are present)
201818215
Rcpf:2001351 R6C: 10.00 --
DS: 0.00 IT: 0.00
10/26/2018 L. S. , Dpty Clerk:
PRULR S U1-NEIL-,-Ph D:PASCO CLERK- g CONP.TROLLE
10OR 1111 19 1�2ogm PG '�C�;
OR BK �
Permit No. Parcel ID No 24-26-21-0100-00000-0700
NOTICE OF COMMENCEMENT
State of Florida county of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 70
Street Address: 3052 Moulden Hollow Drive Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W Cypress St, Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(If other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. Surety: - N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 10 day of September by
Steve Robert Smith as Vice President (t ority,a er,trustee,attorney in fact)for
Lennar Homes LLC me on alf of whom instrument was executed).
Personally Known 2 OR Produced Identification❑ Nota rgnature
Type of Identification Produced Name(Print) Elissa Holleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief. ]
ELISSAM,HOLLERAN Signature of Natural Person Signing Above
41.C111mtnleslonNFF985837
�? Ex0013 June 8,2020
wpdata/bcs/bcsform:, nderThruTroyFralnlmudrnce10o.3WIOto
S TA:TE OF FLORIDA, COUNTY OF PASCO
THIS IS TO CERTIFY THAT THE FOREGOING IS A
TRUE AND CORRECT COPY OF THE DOCUMENT
ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
o WIT MY HAND AN F SEA H
In ,ndlye 7-7'ust �
DAY OF a
PAULA S. ONE ERK&COMPTROLLER
BY DEPUTY CLERK
PASCO COUNTY, FLORIDA
Permit No, 2—o467
Date Permitted I --
Builder Name/Owner Name lipnfl0-r' �`2sS ,��� Control#
County Parcel No. 24-2.6-2-(-010b,000OQ-t)700 SubDiv: wo(dtil4leer
Address/Location -3052- (koL. VCkt'1 t-tt 4)lout,) j
Classification/Type of Use �t to , t4 2 S
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2r2
Exempt ❑Yes [] No How Determined
Impact Fee Amount $. 31(O3Z OU Zone No. TAZ:
SCHOOL IMPACT FEE �$
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑ Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑ No How Determined Total Amount
RESOURCEFEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing !
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
ing e aml .y we ,ing
Plan Review Comments
1: _F.F.E. shall-�be a.minimum:of 8" above,the road.elevation and an engineered.site plan.
2. :Lots shall be graded,to comply with R401.3 of the F.B.C.
3.: ;Compaction test required if 24 or more of fill dirt is brought in:at any one place: -
4: Tie in.survey reguired before pouring concrete.
5.: Driveways:require a R;O:W. use permit. A114 sides of driveway thru the sidewalk shall Have.
expansion material:
6.. All setbacks.shall be met..
.7.: All property:markers shall be uncovered and marked.at time of first.'inspection:
8.: All A.D.A.-requirements shall be met..'.
9.: Na electric,plumbing,.mechanical, or fframing shall be covered without an inspection and
approval first. ..
10. All Garages shall:comply-with section R302:6.of the F.B.C.(Fire Separation).:
11.Appliances_shall riot.be installed in.a location'where subject to mechanical damage unless.
protected:by approved barriers: M303.4 of the F.B.0
12. Water heaters shall_comply with section:P607.3 of the F.B.C.,
13. Foundation supports-for A/C units shall be raised at least 3'.' above finished grade.. M1308.-1
14. Return-air in all.:bedrooms..F:B.C. .M1620.4..
15. Smoke detectors are to be installeddn' ace6rdance:with R313:.1 of theT.B.C.
.16.: All glazing requirements are:.to bein accordance with R308.4.of the F.B.C.
17. All means_of egress,are to be in accordance with R3 1 Y of the F:B.C. ..
18. `-"Green gypsum-board" shall not be used.a' s.a backer.in:showers or tubs. R702.4:2 F.B.C.
19. Combination-type AFCI breakers.are,required at all locations requiring an AFCI type breaker: . .
20. Carbon monoxide alarms will be required in.new construction that uses fossil-burning heating
or appliances or an attached garage:_ They shalllie-installed in accordance with.the V.R.C.
21. Al_l plumbing, mechanical, and.electrical shall:be separate from unit to:unit: This includes all
underground:plumbing and electric:
22. All 2016.N:E:C. Codes.will.be enforced:.'
23. Tamper-*Resistant Receptacles in accordance with 406.11-of the 2016 ME C
.24.-An accordance:With the Land Development.Code;lots.shall be sodded before final at least 10
feet around the structure. . .
25._Blower door:test and blown in in-nsulation card shall be provided:before C:O:
26 A copy of the energy edels.shall be with permit at all times.,
2Z. Copy of final insulation report shall be:provided with permit before.finab
.28:No fence:pool or screen enclosure is issued with this permit
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code Oh Edition
R.O.W.-Right of .
A:D.A:-Americans with Disabilities Act N.E.C.-:National Electric Code(2016)
Lennar Homes 3052 Molden Hollow Dr.-2,376 sq ft
Column
SQ. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,487.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,150.00
Public Fee 1%
TOTAL $ 2,150.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER:1 $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,277.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,877.97
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting 813 363 __ 2891
1 1 1 1 1 1 1 1 1 1 if I I I I I I I I I 1 1 1 1 1 1
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 3052 Moulden Hollow Drive LOT# 0700
SUBDIVISION Hidden River Phase One B PARCEL ID# 24-26-21-0100-00000-0700
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED P
NEW CONSTR ADD/ALT 0 SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE u v u SFR COMM OTHER
TYPE OF CONSTRUCTION 10 u BLOCK FRAME 0 STEEL
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R IF 2376 SQ FOOTAGE 1936 HEIGHT 1 Story
BUILDING co 1 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY W.R.E.C.
• r
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
,7..,6
=GAS � ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES CIO
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE 77REGISTERED Y/ N FEE CURREN
Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 License# CGC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N I FEE CURREN Y/N
Address 1034 Skipper Road, Tampa, FL 33613 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE REGISTERED Y/ N iFEE CURREN I Y/N
Address P.O. Box 5308, Bayonet, 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE R5PISIERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 674-53 I License# I CAC058062
OTHER COMPANY =Sterring Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal Line Blvd, Spring ill, FL 34607 License# 1 CCC057991
1111111111111111111111111111111111111111111111111111111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy,Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a.separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically.included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmegPelFore me this Subscribed ands rn to ffirmed)before me this
i U-0ep-1 o by Ashlee Call i m-Sep-1a y ee Callahan
Who is/are personally kno o me or. Who is/are p ally known to me or has/have preduee4
as identification. identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped
E40RIMAIHAMUMN ernrt3t�mnrll�pa e r
�C�rnm�itam�,pPla�3�'' I ;I�Jt�r�d;�4��
.
��kl�dtilt��d',g9�0 i i �1fJ��'iYN'riaJ(Ft141S11P1AN1�7L��111 �
&�dd�►t�'r �+lelt�lIt�s,7i14�1G11 _
24-26-21-0100-00000-0700 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, October 27, 2018
Parcel ID 24-26-21-0100-00000-0700 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $29,040
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3052 MOULDEN HOLLOW DRIVE
ZEPHYRHILLS, FL 33540
Just Value $29,040
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $29,040
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 70 Taxable Value $29,040
OR 9799 PG 708
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use _ Description Zoning lunits Type Price Condition Value _
1 j 0100 SFR -1 MPUD 6,000.00 SF $4.75 1.00 $28,500
2 j 0100 SFR i MPUD 600.00 SF $0.90 1.00 j $540
Additional Land Information _
Acres 0.15 Tax Area 30ZH I F ME A -- I Residential Code HDRVCPI
I { Code
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line IDescription jyear UnitsValue
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page Type_ DOR Code Condition Amount
10/2018 9799 / 0708 Warranty Deed 05 _ Vacant Multi-Parcel Sale
09/2011 8606 / 3376 Warranty Deed 05 Vacant Multi-Parcel Sale
06/2010 8360 / 1872 Certificate of Title 12 Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126240100000000700 10/29/2018
EL 7
114
A
AC
112
3 ?6..•.-
FF EL
1
7.5
A
PF EL
74
73
tern..:. . p
NJ
FFF EL
71
44 , .r' a r a. .it
Po
100
�nA
•n ''� A{j .i�'�'�G i� Ind{
.. -
• •< ;<� � ' �1..�� �t�1��ssA' J'���f�. } ' r i • ,of � a ,h
FFM
46
FFEL
47 Ile
481 .
Fi R h R f h 4
A.
HE
49 AI
' �. !''\''w. , •`< ''Y a � � �y.�` � b Jlr • R +ry/IY it~
5Q MA
ow
.01
68
�. ,. r- �# FF F . 7 ,..
�. 52 r
SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 70 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6600.00 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =_1556 __SQ. FT.
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 40 -SO. FT. M UNDERGROUND FOOTER, STEM WALL, AND
GARAGE =_407 SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
LEGEND: COVERED LANAI =_N/_A_SQ. FT. SHOWN.
-vvn = PROPOSED DRAINAGE FLOW PATIO =_23__-SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
CONC. DRIVE = 475 _SQ- FT.
(00.00) PROPOSED GRADE a NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE A/C & CONC PAD =--9`__SQ. FT.
PRIVATE SIDEWALK =_ 29 SQ. FT. in DESCRIPTION NOT CONTAINING PLAT BOOK AND
NOTES: IMPERVIOUS =_ 38 % PAGE INDICATES THAT PLAT IS IN
LOT GRADING TYPE = A
-_ 2539 _SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION = SOD = 4061 SQ. FT, CHANGE AND/OR REVISION.
FRONT SETBACK = 20'1 OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
SIDE SETBACK = 1 RIGHT OF WAY = 720_00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 0' DRIVE APRON = 144 SQ. FT.
PUBLIC SIDEWALK = 240 SQ• FT, STRUCTURE TIES SHOWN HEREON DENOTES
SOD = 336 _SQ. FT, MEASUREMENT FROM FORM BOARDS/FOUNDATION
TO PROPERTY LINE.
TOTALS • = 10' DRAINAGE/UTILITY EASEMENT
AREA =_7320.00 SQ. FT.
DRIVEWAY =_6_19 _SQ. FT.
SIDEWALK =_26_9 _SQ. FT.
SOD =_43 L7 SQ. FT.
PLAT
�PRM(P) BOUNDARY o°
h�
LOT 71
TRACT "B"
HIDDEN RIVER PHASE ONE A
(PLAT BOOK 74, PAGES 101-121)
WETLAND CONSERVATION
AREA
rn
o •��o. -o �O. o
y�;�`7
00)
o Q� / 6'0 L°5q. '0
o0 6D
L \ s
U),
o Q </ f LOT 69
080)
a T
C, BO DARY
(V
'•I
00 \
0
O
m PROPOSED:
LOWEST FLOOR ELEVATIONS:
3 LIVING AREA: 72.30'
Cj DESCRIPTION: GARAGE AREA: 71.76'
ELEVATIONS REFERENCED TO
m LOT 70, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL
z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA
cl OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
L
u,
a
a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9 30 1992
Project Number: Square Feet: 6600.00 t LENNAR HOMES
Z LEGEND:
, CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA.- %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
2 F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
m PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
a, REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
m U P= UTILITY POLE, W F= WOOD FENCE
CL
< JOHN R.BEACH&ASSOCIATES INC. Drawn By:
SMS
SURVEYORS AND MAPPERS
911 WEST ST. PETERSBURG DRIVE Checked By:
y ONE OLDSMAR, FLORIDA 34677 JR8
WAY (813) 854-1276 FAX (813) 855-8370 Scale: J
1"=30' i
NOT VALID VATHOUT THE SIGNATURE AND Date: PLOT PLAN 9/13/18 ACS
o THE ORIGINAL RAISED SEAL OF A FLORIDA NAT DATE
LICENSED SURVEYOR AND MAPPER JOHN R. B H -
Revisions: FLORIDA REG. ND SURVEYOR No. 2984 LB 4493
JEFF M. HART
LL SURVEYOR & MAPPER No.7123
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes 0070
Street: 3052 Moulden Hollow Drive Permit Office: �;t�,�Qf�phyrhills
City,State,Zip: FL, Permit Number:�(j'tU
Owner: Lennar Homes Jurisdiction: 61„oco l I��
Design Location: FL,Tampa County: Pasco(Fl ri a imate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 309.76
a. U-Factor: Dbl, U=0.54 101.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U=Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1936.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS
Total Baseline Loads: 62.90
I hereby certify that the plans and specifications covered by Review of the plans and HE ST.g2�
this calculation are in compliance with the Florida Energy specifications covered by this '
Code. calculation indicates compliancewith the Florida Energy Code. b:. Motif" .Y
PREPARED BY: Dave Aupich Before construction is completed
this building will be inspected for
DATE: 9 P
compliance with Section 553.908
I hereby certify that this building,as designed, is in compli a Florida Statutes. +
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: OCT n 2018DATE:
- Compliance requires certification b the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accorda ce with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes 0070
Street: 3052 Moulden Hollow Drive Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 11.Duct
c. R= ft2
s R ft2
7. Windows(157.3 sqft.) Description Area. a.Sup:Attic, Ret:family rm,AH: laundry rm 6 309.76
a. U-Factor: Dbl, U=0.54 101.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl, U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1936.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS
Total Baseline Loads: 62.90
1 hereby certify that the plans and specifications covered by Review of the plans and 11KE S ,1?,
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
/w/�G with the Florida Energy Code. 1~ tiff", ',�I"
'Dave
AWl
PREPARED BY: ,`t h Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. 00D4
OWNER/AGENT: BUILDING OF CIAL.
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941B1_sf ADS Carrier Builder Name: Lennar Homes 0070
Street: 3052 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1454.60 ftz
b.Frame-Wood,Adjacent R=11.0 506.78 ftZ
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ftz
6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ft2
Conditioned floor area below grade(ftz) 0 c. R= ftz
11.Duct
s R ftz
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 309.76
a. U-Factor: Dbl,U=0.54 101.00 ftz
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ftz
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-Oh-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features
b.N/A R= ftz None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.62 PASS
Total Baseline Loads: 62.90
I hereby certify that the plans and specifications covered by Review of the plans and O�'g)tE 5�.91
this calculation are in compliance with the Florida Energy specifications covered by this ;
Code. calculation indicates compliance
A,,/�C with the Florida Energy Code. r�,,,FC�; _? ,t O
�aVe (NI
PREPARED BY: t! h Before construction is completed r �r
DATE: this building will be inspected for ;�;;i. a
compliance with Section 553.908 *_
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. CCT},_ iJ
OWNER/AGENT: BUILDING OFA4�
DATE: DATE: �V"I ` s
Oor
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 1941B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1936 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 `Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: No County: Pasco
Jurisdiction: Whole House Fan: No City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1936 16360.3
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 master 210 1680 No 2 1 1 Yes Yes Yes
2 family rm 341 3171.3 No 0 1 Yes Yes Yes
3 — cafe 161 1288 No 0 1 Yes Yes Yes
4 kit 182 1692.6 Yes 0 1 Yes Yes Yes
5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes
6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes
7 bath2 61 488 No 0 1 Yes Yes Yes
8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes
9 o wic 104 832 No 0 1 Yes Yes Yes
10 privy 24 192 No 0 1 Yes Yes Yes
11 o bath 117 936 No 0 1 Yes Yes Yes
12 laundry rm 100 800 No 0 1 Yes Yes Yes
13 foyer 148 1376.4 No 0 1 Yes Yes Yes
14 hall 43 344 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft' ____ 0 0 1
2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ftz ___ 0- 0 1
3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ftZ 0 0 1
4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ftZ -__ 1 0 0
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 e__ 0 0 1
6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 0 0 1
7Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 ____ 1 0 0
8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 ____ 0 0 1
9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 0 0 1
10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 ____ 1 0 0
11Slab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 e__ 1 0 0
12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 ____ 1 0 0
13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 ____ 1 0 0
14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 ____ 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1936 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood
2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood
3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood
4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood
5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood
6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood
7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood
8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood
9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood
10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood
11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood
12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood
13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood
14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6
5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
o
To Wall Ty pe
_ 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0
_ 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0
3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0
4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0
5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
_ 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0
7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0
8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0
10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.23 0.01 0
14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0
15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0
_16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.23 0.01 0
17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0
18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 0 0.23 0.01 0
19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0
20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 - 2 0 8 0 16.0 ft2 0 0 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2
2 N=>NE Insulated foyer None .2 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
/ Wall Overhang
v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 S=>SW 1 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in Oft 11 in None None
2 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 46.0 ft2 1 ft 0 in Oft 11 in None None
3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 8 in None None
4 E=>SE 7 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in Oft 11 in None None
5 E=>SE 8 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in Oft 11 in None None
6 N=>NE 10 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in Oft 11 in None None
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 416ft2 416ft2 43.7ft 8ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000376 1908.7 104.79 197.06 .2844 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC , Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ --Supply--- —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 309.76 family rm 77.44 ft Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1
r'
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb ]Mar A r Ma [X]Jun ri
Jul n
Augri
Se Oct [ ]Nov Dec
Heatin Jan f X Feb f X]Mar E j APr, f May [ ]Jun Jul Au SeP Oct [X]Nov X Dec
Ventin Jan [ Feb X Mar [X A r [ Ma [ ]Jun Jul Aug Se [X Oct [X]Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 Main
Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Casita with Bonus
Name: Signature:
Rating Compant: Date:
7/26/2018 12:37 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/family rm
3. No. of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13.Cooling system: Capacity 34.8
a)Split system SEER 15.0
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1936 d) Room unit/PTAC EER
e) Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.551
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14. Heating system: Capacity 34.6
c)Area 7c. 157.3 a)Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
8.Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised (R-value) 9b. 15.Water heating system
c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d) Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10B1. 11.0
2. Masonry(Insulation R-value) 1062.
16. HVAC credits claimed (Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e) Multizone heating credit
f) Programmable thermostat Yes
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded) in thi .home before final inspection.Otherwise,a new EPL
display card will be completed based on installed c compliant features.
Builder Signature: Date: 09/17/18
Address of New Home: 3 Z2Moulden Hollow Drive City/FL Zip: , FL ZeFhyrhills, FL 33540
7/26/201 8 12:38:37 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Building Anal Job: 1941B1 sf ADS Carrier
g Y$lS Date: 9/1712018
Entire House By: Dave
Bayonet Plumbing Heating and Air
F;Oject In • mcition,
For: Lennar Homes
® - •Ksi • • • 150
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Wails 5.2 8141 27.8 Ducts
Glazing 30.2 5225 17.9 Walls
Doors 23.5 466 1.6 Infiltration
Ceilings 1.3 2429 8.3
Floors 3.5 6726 23.0
Infiltration 1.7 3056 10.4
Ducts 3221 11.0
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Other Ceilings
Adjustments 0
Total 1 1 29263 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 4320 16.2 wall
Glazing 54.1 9360 35.2 Internal Gains
Doors 18.4 365 1.4
Ceilings 1.7 3358 12.6
Floors 0 0 0
Infiltration 0.4 684 2.6 i Ducts
Ducts 3628 13.6
Ventilation 0 0
Internal gains 4900 18.4 Glazing Infiltration
Blower 0 0
Adjustments 0 Ceilings
Total 26614 100.0 Other
Latent Cooling Load=4080 Btuh
Overall U-value= 0.104 Btuh/ft2-°F
Data entries checked.
-Fk wri-ghtsoft- 2018-Sep-1714:09:55
CI1 w i4 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..equipment\1941 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW
Project Summary Job: 1941B1 sf ADS Carrier
J ry Date: 9/17/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
• - • •
For: Lennar Homes
Notes: FBC 2017
- • • •
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 26042 Btuh Structure 22986 Btuh
Ducts 3221 Btuh Ducts 3628 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 29263 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26614 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3419 Btuh
Ducts 660 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1936 1936 Equipment latent load 4080 Btuh
Volume(ft3) 16360 16360
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30694 Btuh
Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC536AO0300 Cond 25HBC536AO0300
AHRI ref 9155179 Coil FX4DNF037L
AHRI ref 9155179
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh
Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh
Temperature rise 26 OF Total cooling 34800 Btuh
Actual air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.041 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.87
Capacity balance point= 28 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-F - wrightsoft- 2018-Sep-17 14:09:55
o 1-1°- l-1-^•--.1 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCK ...equipment%1941 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW
Manual S Compliance Report Job: 1941B1 sf ADS Carrier
Date: 9/1712018
Entire House By: Dave
Bayonet Plumbing Heating'and Air
Rroj4d informa •
For: Lennar Homes
® • i ng.- • •
Design Conditions
Outdoor design DB: 91XF Sensible gain: 26614 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.3°F Latent gain: 4080 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 30694 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Sensible capacity: 29580 Btuh 111% of load
Latent capacity: 5220 Btuh 128% of load
Total capacity: 34800 Btuh 113% of load SHR: 85%
at n
• • •
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 29263 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Output capacity: 26331 - Btuh 90% of load Capacity balance: 28 °F
Supplemental heat required: 2932 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
-Fk wrightsoft, 2018-Sep-1714:09:55
CA >.—��•,��M.,ona., Right-Suite® 9
Universal 2018 18.0.16 RSU05714 Page 1
Ar- ..equipment\1941 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces:SW
Aobe/v ,CoV t'L ID
PASCO COUNTY
PASC am\ DEV87o Citi ens DMNT R�VICES Date:2/11/2019
COUNTY FLORIDAIV- New Port Richey, FL 34654
Orri'l Srnc:rs.Fnin"y r Pl.u:rs. 722�7-847-2411
Receipt#: 1830070
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
impact Fee Residential Solid 24503100-329010 1.00 1427395 $60.30 $60.30 1830070 2111/19
Waste Single Family
TOTALS: $60.30 $60.30
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1830070 Check 1156456 BCCCP59W 02/11/2019 $60.30
Total Payments: $60.30
Pavor Address Phone
Lenhar Homes, LLC
Comments: /�
3052 Moulden Hollow DR Ij
v
-- - While you will be paying your bill with Pasco County Development Services;the full amount of the credit card or e•check fees,NOT shown above,is collected by -
First Billing payment services.
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 2/11/2019 Page 1 of 1
Jet Stream° Ultra Blowing Wool Insulation kiufpW
Attic and Cavity Wall Card D� Mo u I Jem �6 16i ih lime h jave, e4ierf
Batts and Blankets Equipment Required
When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'/4'internal corrugation,a minimum length
recommendations,Knauf Insulation batts and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed
provide the full R-value. rate is 15-25 lbs/minute.
R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application)
To obtain an The stated thermal resistance(R-value)Is provided by installing in accordance with the manufacturer's instructions.Failure to install the
insulation resistanca Installed insulation should required number of bags per 1,000 square feet and exceeding Me maximum square feet of coverage per bag as recommended by the label
(R-Value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer.
R-49 13.75' Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs.
R-38HD 10.25"
R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum
R-30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF
insulation per 1,000 square feet Contents of this The weight per square
R-30 10.00" Cavity resistance of net area should not hag should not feet of Installed insulation
R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than:
R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs.
R-21HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs.
R-19 6.25"**
R-15HD 3.50" 2"x 8" 7.25" R 31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 Ibs,
R-13 3.50" 2"x 10" 9.25° 1 R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs.
R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be Installed property.
R-8 2.50"
"R48 in a 5.5'cavity.Conforms toA8TMC665 and Federal Open Attic Application Bag Net Weight-Nominal 32lbs.,Minimum 31 lbs.
Specificaflon HH-1.521F. Minimum
Bags/ Maximum Minimum Initial Settled
Framing Adjustment 1,000 SF Coverage Weight Installed Thickness**
To compensate for framing members,the number of bags per The number of bags/ Contents of this The wef ht(SF Thickness
1,000 s ft.of area to be insulated should be as shown below. R-Value* g Contents of this
q• 1,000 SF of net area hag should not of installed Installed insulation hag should
Ba s/MSF Ba S/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more
g 9 resistance(R-Value)of: than: more than: he less than than: than:
Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF 952 lbs. 19.750" 19.750"
R-Value Dimensions Framing Framing
2x4 29.2 29.4 R49 23.5 42.5 SF .753 lbs. 16.375' 16.375"
R-60 2x6 28.9 29.1 R44 20.9 47.8 SF .670lbs. 14.875" 14.875"
2x8 1 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000"
2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375"
R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125"
2x8 22.4 22.7 R-22 9.8 102.2 SF 313 lbs. 7.750" 7.750"
2x4 20.4 20.6
R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750"
2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750"
2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000° 4.000"
R-38 2x6 17.0 17.2 Bag Net Weight-Nominal32 lbs.,Knimum31Its.
2x8 16.7 17.0 Coverage and installation data were determined using a Votu4Aal1&II bowing machine in third Bearwn Is'gate opening,2.0 psi air pressure and 150'of W intemaly-comgated hose.
2x4 13,2 13.3 This product conforms to the performance requirements ofASTM C 764,Type I,and cancelled Federal Specification HH-I.1030B,Type I,Class B.R-values are determined In accordance with C 687 and C 618.
"R'means resistance to heat Dow.The higher the R-value,the greater the insulating power.To gel the marked R-value,It is essential that this Insulation be Installed properly.If you do it yourself,gel inmuo-
R-30 2x6 12.9 13.1 Dons and follow them carefully.Instructions do not come with this package.
"Based on Third Party 2-year settling study,the predicted settlement over a 20-year period wauld be 1 percent or less.This amount of setting is thermally Insignificant.Therefore,the installed and settled
2x8 12.6 12.9 tNdmesses are effectively the same.
2X4 11.3 11.4 Volu-MaDdll Is a registered trademark at Unisul.
R-26 2x6 11.0 11.2 Builder's Insulation Statement
2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of...
2x4 9.3 9.5 R-Value Thickness
R-22 2x6 9.1 9.3 Attic Area R- at Inches
2x8 8.8 9.1 Sloped Ceilings R- at Inches
2x4 7.9 8.1 Walls R- at Inches
R-19 2x6 7.7 7.9 Floors(over an unheated crawls ace) R- at Inches
2x8 7.4 7.7
2x4 5.3 5.4 Crawl Space Perimeter R- at Inches
R-13 2x6 5.0 5.2 Date Installed
2x8 4.8 5.0 Blow s lation has been' t led in conformance with the above reco�n��do to provide an R-value of:
2x4 4.3 4.4 R�_using bags of this insulation to cover�-- square feet of area
R-11 2x6 4.1 4.3 at a minimum thickness of inches.
2x8 3.8 4.1
1�kj-iidjng alld ('t)nstl'uctioll Services
PANU
COUNTY Fi-oRHIVA
ES-lo-wev 00cm- 7est Report Form
Property Address: #:
,3o,T2 IM&�,le-l-eit-)
Permit#: Testing Company Name: SKYETEC
Test Date, j
17 Tester Name:
KIM SWEARINGEN
Tester Cert 41. 920541 Contact Phone: 904 482 4260
r- Email: BHARRIS@SKYETEC.COM
402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes
per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).As required by
the Building Official, testing shall be conducted by an approved third party. A written report of the results of the test
shall be signed by the party conducting the test(including Agency Name) and provided to the Building Official prior
to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled
penetrations of the building thermal envelope.
During testing:(check to verify condition met)
Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended
weather-stripping or other I
XDampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond
intended infiltration
Ointerior doors,if installed at the time of the test,shall be open
Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed
CKHeating and cooling systems,if installed at the time of the test,shall be turned off
Upply and return registers,if installed at the time of the test,shall be fully open
Vb Building volume(ft')
Q5o Airflow at 50 Pascal(CFM)
ACHM Air changes per hour at 50 Pascal
Q50 x 60+Vb = ACH50 (3.0 A CH minimum)
Pass Fail ❑
❑Outside Air mechanically introduced to space(less than 3.0 ACH)
I hereby certify that the above envelope leakage performance results demonstrate compliance
iZthlorid En Code requirements in accordance with Section R402.4.1.2.
14" 4e�
Signature of Tester Date