HomeMy WebLinkAbout18-20408 CITY OF ZEPHYRHILLS
5335-8TH STREET
_ , l (813)780-0020 20408
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20408 Issued: 10/31/2018 Address: 3304 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class-of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 226,201.20 Total Fees: 17,565.47 Subdivision: HIDDEN RIVER
Amount Paid: 17,565.47 Date Paid: 10/31/2018 Parcel Number: 24-26-21-0100-00000-0920
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,008 SQ FT
APPLICATION FEES
BUILDING FEE 1,273.49 ELECTRICAL FEE 1 264.38 PLUMBING FEE 176.25
MECHANICAL FEE 123.38 SEWER CONNECTION RESIDEN 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
ocf J i�
I . A
So
C�as
Inspections a wired
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
�A )w_ W I ! � &__
'UUN SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Lennar Homes-3304 Kresterbrooke Lane-2,008 sq ft
o umn ts
SQ. FEET PRICE
MAIN OR LIVING: 2,008 $ 112.65
OTHER AREA UNDER ROOF: - :$ 88.00
OTHER: - $ -
VALUATION $ 226,201.20
i
FEE SHEET $ 1,175.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
i
BUILDING: $ 1,273.50
ELECTRICAL: $ 264.38
PLUMBING: $ 176.25
MECHANICAL: $ 123.38
SUB-TOTAL $ 1,837.50
TOTAL $ 1,837.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,964.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,565.47
a� m
I:CORIUR
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: /—CA Aa,
Date Received: ,/ /
Site: 3,3D7" l�J�►'t ,
Permit Type: CS fe T4U
n , l Z6
Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑
I
This comment sheet shall be kept with the permit and/or plan .
Kalvin Switzer—Plans Examiner Date Co actor and/or Homeowner
(Required when comments are present)
2018182157.
Rcpt c 2001351- -Rec: -10:0® - -----
DS: 0.00 IT: 0.00
10/26/2018 L. S. , Dpty Clerk
PROLR-S,-U'-NE1L;Ph K-D.PASCo CLERK &-COMPTROLLE,,
10/26/2018 12:19 m 1 of 1
OR BK 980 PG 752
Permit No. Parcel ID No 24-26-21-0100-00000-0920
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 92
Street Address: 3304 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information:' Lennar Homes, LLC.
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
'Interest in Property:
Name of Fee Simple Titleholder: N/A
(If other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. Surety: N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS c
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 10 day of September ,by
Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for
Lennar Homes, LLC (name ument was executed).
Personally Known 9 OR Produced Identification❑ Notary Sl5ea re
Type of Identification Produced Name(Print) Elissa Holleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have,read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
, } ELISSAM,HOLLIRAN Signature of Natural Person Signing Above
.Cemmleel04 FF 88583T
Expires June 8,2020
wpdata/bcs/bcsform; 56ndMfi;uTmy.RInIm unit nce too 3W1019
Sim, �� STA E '.''F FLORIDA, COUNTY OF PASCO
'I'I-iiS IS TO CERTIFY'THA('THE FOREGOING IS
AIN
TRUE AND CORRECT COPY OF THE DOCUMENT
ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
WIT S IiY HAND�AND OFF�ALAL T�1
.In Gmf"We T-wt V -0 (/
0 DAY OF 2�
��11 e...r. PA, S.O' ER & ROLLER
'" 188.7 `; BY� DEPUTY CLERK
PASCO COUNTY, FLORIDA
Permit No. '2 0! -D8
Date Permitted
!
Builder Name/Owner Name �_e* 1-a LL(!-- Control#
County Parcel No. SubDiv: 4idde t, iev txer
Address/Location 33aq
Classification/Type of Use
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: bO
Exempt ❑Yes ❑ No How Determined
Impact Fee Amount $. 316 32-, n Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ ��� Z
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑ Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amount C ' _
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Sing e Family.Dwelling .
Plan Review' Comments
1:- RFI `shall be a minimum of.8" above the road elevation and an engineered site plan.
2.. Lots shall be graded to comply with R401.3 of the F.R.C.
3. Compaction test required..if'24" or more of fill dirt is brought in:ai any one-place:
4:. Tie in survey required before pouring concrete.
5.' Driveways require a R.O.W. use permit.. All-4 sides of driveway thru the sidewalk shall have
:expansion matenal:
'6. -All. setbacks.shall be met...
7.: All property.markers shall be.uncovered and marked at time of first.inspection:
8:- .All A:D.A. requirements shall'be met. .
9.' No electric;plumbing, mechanical,or fraining shall be covered without an.inspection and
approval first.
10..All Garages shaR comply with.section R302.6:of the F.B.C,: (Fire Separation).
11.Appliances shall not:be installed in:a location-where subject to mechanical damage unless
p-
rotected bY approved roved barriers. M303.4 of the F.B.0. . _ .
12. Water heaters shall comply with section P607.3 of the F.B.C:
13. Foundation supports for.A/C units shall be raised at least 3 above finished grade. M1308.1.
14. Return air in all_bedrooms. F.B.C. .M.1620.4.
15. Smoke detectors are to be installed-in accordance with:R313:1 of the:F.B.C.
16: All glazing requirements are to be in accordance with R308.4 of the F.B.C.
17. All means,of egress are to be in:accordaiice with R3I t of the R.B.G.
18. `.`Green gypsum board"shall riot be used as a backer_in:showers or tubs. R702.4.2.F.B.C.
19.'Combination-type AFCI-breakers are required-at all.locations requiring-an AFCI,type breaker.-
Carbon'Monoxide alarms:will be required in new construction that uses fossil-burning heating
or appliances or an attached garage:. They shall be installed in accordance with the F.B.C.
21. All plumbing,mechanical, and electrical shall be separate from unit-to:unit. This includes ali .
underground plumbing and electric.
22. A112016.N.E:C:. Codes.Will be enforced.
23.Tamper-'Resistant Receptacles in accordance with 406.11 of the 2016 N.E.C..
24::In accordance.with the Land.Development.Code, lots.shall be sodded before final at least 10
feet around.the structure.
25. Blower door test and blown in insulationi card shall be'provided before C.O.
26.A cony of the energy edcls.shall be with permit at all times.
27. Copy of final insulation report shall be,iwovided.with:permit before:rinaL
28. No fence;pool or screen enclosure is issued with this periniz
F.F.E.-Finished Floor-Elevation
F.B.C- Florida Building Code 6 h Edition .
R.O.W:-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-.National Electric Code(2016)
Lennar Homes 3304 Kresterbrooke Ln.-2,008 sq ft
Column ts
SQ., FEET PRICE
MAIN OR LIVING: 2,008; $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 226,201.20
FEE SHEET $ 1,175.00
ADDRESS $ 40.00
DRIVEWAY1 $ 40.00
BUILDING: $ 1,278.50
ELECTRICAL: $ 264.38
PLUMBING: $ 176.25
MECHANICAL: $ 123.38
SUB-TOTAL $ 1,842.50
Public Fee 1%
TOTAL $ 1,842.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 5,969.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,570.47
24-26-21-0100-00000-0920 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, October 27, 2018
Parcel ID 24-26-21-0100-00000-0920 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $27,575
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3304 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540
Just Value $27,575
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,575
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 92 Taxable Value $27,575
OR 9799 PG 708
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use DescriptionZoning Units Type Price lCondition Va Value
1 0100 SFR MPUD 6,000.00 I SF $4.50 1.00 I $27,000
2 0100 SFR MPUD 639.00. SF $0.90 ; 1.00 $575
Additional Land Information
Acres F
0.15 Tax Area 30ZH FEMA
_ Code -- Residential Code HDRVLPI
�
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ Extra Features (Card: 001 of 001)
Line VIDescription Near jUnits _�alue
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page Type _ DOR Code_ lCondition Amount
10/2018 1 9799 / 0708 Warranty Deed 05 Vacant Multi-Parcel Sale
09/2011 8606 / 3376 Warranty Deed 05 Vacant Multi-Parcel Sale
06/2010 ( 8360 / 1872 Certificate of Title 12 ( Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126240100000000920 10/29/2018
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received SEI 1 3 2090 813 363 _ 2891
Phone Contact for Permitting
1 1 1 1 1 1 1 1 1 1 1 1 1
Owner's Name Lennar Homes,LLC Owner Phone Number r813.574.5700
Owner's Address 1
4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address I
N/A
JOB ADDRESS 3304 Kresterbrooke Lane LOT# 0920
SUBDIVISION Hidden River Phase One B PARCEL ID# 24-26-21-0100-00000-0920
rah (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II./ II NEW CONSTR B ADD/ALT 0 SIGN Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR Q COMM = OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME = STEEL
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 2008 SQ FOOTAGE 1 HEIGHT 1 Story
BUILDING „/) VALUATION OF TOTAL CONSTRUCTION
`ELECTRICAL $} (�J ® PROGRESS ENERGY W.R.E.C.
AMP SERVICE
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do
7—f .
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/
4600 W.C N
Address ss St.Ste.200,T pa,FL 33607 License# CGC1518166
ELECTRICIAN COMPANY =Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
i
Address 1034 S ' r Road, Tamp L 33613 License# I EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE REGISTERED Y/ N J FEE CURREN Y/N
Address P.O. Bo 08, Bayone 34674-5308 License# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. B 308, Bayonet, F 4674-5308 License# CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal ne Blvd, Spring Hill, FL 34607 License# CCC057991
11111111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary'Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be'subject:to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the-fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land.development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed) ore me this Subscribed and sworn to(or affirme fore me this
I v-Jep-1 o by Ashlee Callaha 1osep-1e by Ashlee Calla
Who is/are personally known to rdVor hasihave PFOdUG Who is/are personall known t or has/have ffedue
as identification. as identification.
Notary Public Notary Public
Commission No. FF98537 Commis on No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
� �IrmYumM.pp�b��T' ; IHiq,l�r�il,�6��
I�.��i9dYlP�d'��Q &Ki�1"iYr1'iajlR�lg4voH,7511GS�115��'Rll
23 22 . 21 I20
19 1 18 1 1 17 1 , 1 IN
FF EL FF FJ_ I FRE I 'L Fr SL I FF EL FF EL F—FPE7L I I
3
A MAC \T=/
I �Rl
4
............ .. .. ............. .......... ..........
.......................
....... . ...........
P, ,""'DAWSON'CHASE��I'DRfVE"'*
.......... ............
FFEL
IR 9:
132
FF EL A4
A 1 317 M I
133
74M A opt"
rm L
JIM
284M
EL A
r r;L
4 Ag 134 40
91
A
7.1
j:FEL rA T
13#5
90
FF
28 Ww
Ffe.
A
FF EL 36
A
T4.W
r
281
FFEL A
FFEL t
rF_FBL 1 137-
813
#
rxl 0
EL
I———————————
28
FWEL I A
Fps.
`K14.557 138
A 87
FF EL I
27 RAW
A
HM:Q FF EL
11439 A n
MAO/
86 7-
A
4� M --------
I 1 ' 277
%
U;wzz.� FF ELA
I FFEL 2781 FF SL
mi
FFEL i 140 Va,237
73M ...... 85 A%
.. ...... ........... ......
FF EL ...... ..........
41
..........................................
84,
A I
in 316 i FFEL I
83
I A I
28
Ff
A PrE
FF M.
A S-
um7 . 143
I FF OL EL Pl:EL
rgm
\MAO/
SL m
.;IA
MA.
gA,
RA A
r r
A*IEL
r r A
A
A
82
LV
4P
28,
PLOT PlYAN NOT ASKETCH ONLY
LRY SURVEY SEC. 24 , TWP. 26 S, RNG. 21 E.
LOT 9 2 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
1� MAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6639_60_SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1556 __SQ. FT.
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =_45_____SQ. FT. UNDERGROUND FOOTER, STEM WALL, AND
GARAGE =_406 _SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
LEGEND:
COVERED LANAI = N/A Q. FT. SHOWN.
= PROPOSED DRAINAGE FLOW PATIO = 23 SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
CONC. DRIVE = 456 SQ. FT. w
(00.00) = PROPOSED GRADE A/C & CONC PAD =_9 _S0. FT. a NOTES TAKE PREFERENCE.
-E-00.00 = EXISTING GRADE
PRIVATE SIDEWALK =_28 _S0. FT. cn DESCRIPTION NOT CONTAINING PLAT BOOK AND
NOTES' IMPERVIOUS =_38 PAGE INDICATES THAT PLAT IS IN
2523 __SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = A SOD = 4117 SQ. FT. CHANGE AND/OR REVISION.
PROPOSED PAD ELEVATION =
FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
SIDE SETBACK = 10' RIGHT OF WAY = 723_60 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 10' DRIVE APRON = 144 _SQ. FT.
PUBLIC SIDEWALK FT. STRUCTURE TIES SHOWN HEREON DENOTES
SOD = 339 _SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
TO PROPERTY LINE.
/ TOTALS • = 10' DRAINAGE/UTILITY EASEMENT
AREA 2 7363 0 S Q. FT.
-
DRIVEWAY 600 SQ. FT_
SIDEWALK = 269—SQ. FT.
PRM(P) SOD FT.
LOT 93
o PLAT
o BOUNDARY
2• 0' � S 89'40'43" E 110.00',, ,LSO
A/C :
N 35.50'
Ld I 54'-0"
Woo
o
p=� w inz�¢� _ � o o
n-a - 20.50' .:` o n Lo' qa I LOT 324
O w^v '; NO„M:. + o�a J o N HIDDEN RIVER PHASE ONE A
ie o _ I o r: o w f0 (PLAT BOOK 74, PAGES 101-121)
..
O
S
(14
zm
Ld
z ..........8..... .....
35....
12 .50' -�
V/ :o o:
W . .. .
Of 21. o' ��J�^^^ �"^^ N 89'36'58" W 1 10.00' �
�'LAT
B NDA
LOT 91
0
fV
in
00
CO
0
PROPOSED:
LOWEST FLOOR ELEVATIONS:
3 LIVING AREA: 74.60'
N DESCRIPTION'• GARAGE AREA: 74.06'
ELEVATIONS REFERENCED TO
m LOT 92, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL
z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA
° OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
w
a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0460 D EFFECTIVE DATE: 9�30 1992
z Project Number: Square Feet: 6639.60 t LENNAR HOMES
Z LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
IM CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
= F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
m PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
y REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
m U P= UTILITY POLE, W F= WOOD FENCE
CL Drawn BY
< JOHN R.BEACH&ASSOCIATES,INC. SMS
SURVEYORS AND MAPPERS Checked 8
911 WEST ST. PETERSBURG DRIVE Y•
w ONE JRB
OLDSMAR, FLORIDA 34677 cal
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
= 1"=30'
NOT VALID WITHOUT THE SIGNATURE AND Date: Pic
LOT PLAN 8/16/18 ACS ���� 2oI6
o THE ORIGINAL RAISED SEAL OF A FLORIDA SIGNAT TE
LICENSED SURVEYOR AND MAPPER JOH R. BEA
Revisions: FL IDA REG. D SURVEYOR No. 2984 LB 4493
JrFF.M. HARTL
i SURVEYOR & MAPPER No.7123
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1551A1 sf ADS Carrier Builder Name: Lennar Homes 0092
Street: 3304 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:"4 b0 Owner: _ Lennar Homes Jurisdiction:6-1-1-208' Git l II
60D
Design Location: FL,Tampa _ County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2
b.Frame-Wood,Adjacent R=11.0 321.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
10.Ceiling Types (1555.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented),_ R=30.0 1555.00 ft2
6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311
a. U-Factor: Dbl,U=0.54 55.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 16.00 ft2
'SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 1.473 ft.
Area Weighted Average SHGC: 0.322 14.Hot water systems
8. Floor Types (1555.0 sg a.Electric Cap:40 gallons
ft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.81 PASS
Total Baseline Loads: 50.93
I hereby certify that the plans and specifications covered by Review of the plans and ftTT .3Tgp
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Dave AGo 11M Before construction is completed
rz
DATE: this building will be inspected for �:-t X_
compliance with Section 553.908
I herebycertify that this building,as desi ne , is in compliance Florida Statutes.
fY 9, 9 P
with the Florida Energy Code. COD;yv6' '
OWNER/AGENT: SEP 13 2018 BUILDING OFFICIAL:
DATE: DATE: ''
Pln
- Compliance requires ceAccordance
cation by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house.
7/25/2018 7:32 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1551A1 sf ADS Carrier Builder Name: Lennar Homes 0092
Street: 3304 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction:611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2
b.Frame-Wood,Adjacent R=11.0 321.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a.worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2
6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(104.3 sqft.) Description Area a.Sup:Attic_,Ret:Main,AH:Main 6 311
a. U-Factor: Dbl,U=0.54 55.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 16.00 ft2
SHGC: SHGC=0.30 - 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 1.473 ft.
Area Weighted Average SHGC: 0.322 14.Hot water systems
8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.81 PASS
Total Baseline Loads: 50.93
I hereby certify that the plans and specifications covered by Review of the plans and OfeTTi>ESTA?,�
this calculation are in compliance with the Florida Energy specifications covered by this ti
Code. calculation indicates compliance
with the Florida Energy Cade. ri rr
haveGal�icGt gY f=00;3 Sti Gw
PREPARED BY: Before construction is completed C
DATE: this building will be inspected for 0 -
t
compliance with Section 553.908 *. „.
I herebycertify that this building,as desi is in compliance Florida Statutes.
fY 9, g
with the Florida Energy Code. CAD WE
OWNER/AGENT: LUOU BUILDING CI
DATE: DATE:
- Compliance requires c ftification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with'envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house.
7/25/2018 7:32 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1551A1 sf ADS Carrier Builder Name: Lennar Homes 0092
Street: 3304 Kresterbrooke Lane Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction:611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2
b.Frame-Wood,Adjacent R=11.0 321.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2
6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311
a. U-Factor: Dbl,U=0.54 55.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 16.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC:
Area Weighted Average Overhang Depth: 1.473 ft.
Area Weighted Average SHGC: 0.322 14.Hot water systems
a.Electric Cap:40 gallons
8. Floor Types (1555.0 sqft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.81 PASS
Total Baseline Loads: 50.93
I hereby certify that the plans and specifications covered by Review of the plans and Q�:Tla sz, TA
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Dave Aut ch Before construction is completed v
DATE: this building will be inspected for
compliance with Section 553.908
I herebycertifythat this building,as desi is in com liance Florida Statutes.
with the Florida Energy Code. g pcoD
OWNER/AGENT: EP1 3 2018 BUILDING OF L:
DATE: DATE:
- Compliance requires cetrBarrier
ion by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed iordance with R403.3.2.1.
-Compliance requires an and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house.
7/25/2018 7:32 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 1551A1 sf ADS Carrier Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1555 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocks 1555 12440
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main - 134 ft 0 1555 ftz 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1684 ftz 0 ftZ Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1555 ft' N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1555 ftZ 0.11 Wood
7/25/2018 7:32 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-201'7 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft2 0 0.600000 0
2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 432.0 ft2 0 0.600000 0
3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0
4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0
5 N=>NE Garage Frame-Wood Main 11 19 8 8 157.3 ft2 0.23 0.01 0
6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ft2 0.23 0.01 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20.ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation =>)changed to Worst Case.
Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 2 ft 0 in 0 ft 9 in Drapes/blinds None
2 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
3 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None
5 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 408 ft2 408 ft2 40 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1451.3 79.68 149.84 .2649 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1
7/25/2018 7:32 AM EnergyGauge®USA Section R405.4.1 Compliant Software -Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 311 ft2 Main 77.8 ft2 Proposed Qn Main —cfm 62.2 cfm 0.04 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar A r May Jun Jul [X]Au Se Oct ki Nov Dec
Heatin Jan Feb X�Mar Apr May rl Jun (ri Jul E ]Aug SepOct Nov Dec
Ventin Jan Feb X Mar A r [ Ma Jun [ Jul ]Au Se [X Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 Main
Name: Signature:
Rating Compant: Date:
7/25/2018 7:32 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity 24.0
a)Split system SEER 15.5
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6.Conditioned floor area(sq.ft.) 6. 1555 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a)U-factor:(weighted average) 7a. 0.556
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.322 14. Heating system: Capacity 24.0
c)Area 7c. 104.3 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8.Skylights c) Electric resistance COP
a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 9.00
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised(R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 11.0
2.Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a)Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c)Knee walls/skylight walls 11 c. d)Multizone cooling credit
d)Radiant barrier installed 11 d. No e)Multizone heating credit
f)Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL
display card will be completed based on installed compliant features.
Builder Signature: Date: 09/10/18
Address of New Home: 3304 Kresterbrooke Lane City/FL Zip: FL Zephyrhills,FL 33540
7/25/2018 7:33:52 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Building Analysis Job: 1551A1 sf ADS Carrier
g Y Date: 8/1712018
Entire House By: Dave
BAYONET PLUMBING COOLING HEATING
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD ('F) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 5.2 7308 31.8 Ducts
Glazing 30.2 3154 13.7 nfiltration
Doors 23.5 480 2.1 Wall
Ceilings 1.3 1950 8.5
Floors 3.7 5815 25.3
Infiltration 1.6 2372 10.3
Ducts 1901 8.3 Floors
Piping 0 0
Humidification 0 0 Glazing
Ventilation 0 0 Doors Ceilings
Adjustments 0
Total 22980 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 3902 20.1
Glazing 59.1 6172 31.8 Walls Internal Gains
Doors 18.4 376 1.9
Ceilings 1.7 2697 13.9
Floors 0 0 0 Ducts
Infiltration 0.3 531 2.7
Ducts 2200 11.3
Ventilation 0 0 Infiltration
Internal gains 3520 18.1
Blower 0 0 Glazing
Adjustments 0 Ceilings
Total 19397 100.0 Other
Latent Cooling Load=2292 Btuh
Overall U-value= 0.103 Btuh/ft2-°F
Data entries checked.
s
-rk- wrigFttsoft- 2018-Sep-10 14:48:09
AEI •W w��m Right-Suite®Universal 2018 18.0.16 RSU05714 page 1
...equipment%1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: W
Project Summary Job: 1551A1 sf ADS Carrier
J ry Date: 8/17/2018
Entire House By: Dave
BAYONET PLUMBING COOLING HEATING
Project • •
For: Lennar Homes
Notes: FBC 2017
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 °F Outside db 91 'F
Inside db 70 °F Inside db 75 'F
Design TD 39 °F Design TD 16 'F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 21079 Btuh Structure 17197 Btuh
Ducts 1901 Btuh Ducts 2200 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 22980 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 19397 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 1902 Btuh
Ducts 390 Btuh
Central vent (0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ft') 1555 1555 Equipment latent load 2292 Btuh
Volume(ft') 12700 12700
Air changes/hour 0.26 0.14 Equipment Total Load(Sen+Lat) 21689 Btuh
Equiv.AVF(cfm) 55 30 Req. total capacity at 0.85 SHR 1.9 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh
Temperature rise 27 'F Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.035 cfm/Btuh Air flow factor 0.041 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 32°F
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
a -Pk- wrightsoft- 2018-Sep-10 14:48:09
•-- Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...equipment11551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: W
Manual S Compliance Re oft Job: 1551A1 sf ADS Carrier
p p Date: 8117/2018
Entire House By: Dave
BAYONET PLUMBING COOLING HEATING
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 19397 Btuh Entering coil DB: 75.7°F
Outdoor design WB: 77.3°F Latent gain: 2292 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21689 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 105% of load
Latent capacity: 3600 Btuh 157% of load
Total capacity: 24000 Btuh 111% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 22980 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 18304 Btuh 80% of load Capacity balance: 32 °F
Supplemental heat required: 4676 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 800 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
wrightsoft- 2018-Sep-10 14:48:09
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
�� ...equipment11551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces: W
Y Z'
PASCO COUNTY
PASCDEVELOPMENT87311 C ens DriveSERVICES Date:2/1k019
COUNTY FLORID New Port Richey,FL 34654
)IT;:Srnr+S.I'+nr rrr l't.nctti. 727-847-2411
NOT /'-'\ PERMIT
Receipt#: 1830805
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1427670 $60.30 $60,30 1830305 2/12119
Waste Single Family
TOTALS: $60.30 $60.30
Receipt# Paid By Check# CC Auth# Cashier ID. Workstation Receipt Date Amt Paid
1830305 Check 1155450 BCCCP59W 0 211 2/2 0 1 9 $60.30
Total Payments: $60.30
Pavor Address a< Phone
Lennar Homes,LLC' -
.17 A
Comments:
3304 Kresterbrooke Lane
-While you vdll be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,'is collected by
First Billing payment services,
MyReports/reports%/PASCOPROD/PASCO/ReceiptPOS V6.rpt 2/12/2019 Page 1 of 1
Jacqueline-Boges '
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Thursday, November 1, 2018 4:29 PM
To: Jacqueline Boges
Subject: [Request received] 3304 Kresterbrooke Lane by#20408
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/248609
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
L- Nov 1 , 1 :28 PM MST
services 3304 kresterbrooke lane by#20408 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
6 G
Wnen Buildings Tech,Vie listen.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Builder Name: LewNA2 ctsvt S
Street: 3304/ -Sr,--,eS Permit Office:
City, State,Zip. 2d7�Pf1y21,11GGS A2 7X-54/6 Permit Number: 26gbI?
Design Location: Jurisdiction:
Square Feet: 15$5 Conditioned Volume: 2-444b
Envelope Leakage Test Results
Single'Point Test Data:
HOUSE PRESSURE: --56 FLOW: 166 7
Leakage Characteristics
EPass Fail
CFM (50): 1J77y
ACH(50): �-
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50
Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5), or (7), Florida Statutes or individuals
licensed as set forth in Section 489.105(3)(T), (g), or(i) or an approved third party. A written report of the results of the test shall be
signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed, beyond the intended weatherstripping or other
infiltration control measures;
2_ Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond-intended
infiltration control measures:
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and
6.Supply and return registers,if installed at the time of the test,shall be fully open
hereby certify that the above envelope leakage Where required by the code official, testing shall be
)erformance results demonstrate compliance with conducted by an approved third-party. A written report of
lorida Energy Code requirements in accordance with the test results shall be signed by the third party
;ection R402.4.1.2. conducting the test and provided to the code official.
>IGNATURE:
)RINTED NAME: "y421d/S BUILDING OFFICIAL:
)ATE: Z"5- DATE:
- I
f
A
Jet Streams° Ultra Blowing Wool Insulation
Attic and Cavity Wall Card G,
L c7� c t�� , ,� �pva if1 fire fo�Q1r evierrgt�
Batts and Blankets Equipment Required q `, (�J
When installed in accordance with the manufacturer's : It ernal corrugation,a mlinimum length
is recommended that a pneumatic blowing machine and a corrugated hose with am inimum'/.'int
recommendations,Knauf Insulation balls and blankets will of 150'.CCilS in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35lbslminute,Recommended feed
pdEdlBVR-6a [ale is Imlbslmiaute.
1M t r r Nnaou ini�u� icnc��
it mil ad Arc ill
,
I
b ain an The stated e�mal IPAS�Iai►r�(R"�alu2j is pro�d�by i�stal►i�g in a fda�ce ih ufe ina�ulaciufef's iNW0113.Fails to MIA mo
i0°! Installed iDSDIaIiDD shDDld �equi� �u�be�of bags per 1,�square feel aid e><c iag the uim sg o(eel 1 c��op pet bag as lout 4 the lid
insulagon rosisfatce not be less Mao, urill resulf in lower;inslalled Revalues,Field blendiog of this pfoduci OM olhef loose Ell insulations is nol iec ommended 4 the manufactuler, i
i (R-Uue)of; i
i
' R-49 13.75" I
Cavity Wall,Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs.
R-3BHD 10.25° !
{ R-38 12.00° R-Value" Bags per 1000 SF Maximum Net Minimum i
To obtain an The number of bags Coverage per Bag Weight per SF
R-30HD 8.25' I insulation per 1,000 square feet Contents of this The weight per square
R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation I
R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than:
R-22 6.50' 2"x 4' j3.50' R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs.
R-21HD 5.50" 2'x 6' �5.50° R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs.
R-19 6.25"" 2"x 8" t7.25' R-31 9.8 Ibs.lcu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs.
R-15HD 3.50"
R-13 3.50" 2'x 10" 19.25° 1 R-39 1.8 Ibs./cu.ft. 43.4 bags 23.1 sq,ft. 1.388 lbs.
R-11 3.50" 'R means resistance to heat flow.The higher the R-valuo,the greater the insu[attisg power.legal the marked R-value,h is essenfial[hall this inswation be Installed property.
R-8 2.50'
••R-lainas.s•cavily Conforms toASTMc6iis and Federal Open Attic Application Bag Net Weight-Nominal32 lbs.,Minimum 31 lbs.
specification HH-1-521F. Minimum
Bags/ Maximum Minimum Initial Settled
Framing Adjustment 1,000 SF Coverage Weight Installed Thickness"
To compensate for framing members,the number of bags per The number of bagsl Contents of this The weightlSF Thickness Contents of this
1,000 sq.ft.of area to be insulated should be as shown below. R-Value' 1,000 SF of net area bag should not of Installed Installed insulation bag should
Ba s/MSF Ba SIMSF To obtain an insulation should not be less cover insulation should not should not be less not cover more
9 9 resistance(R-Value)of: than: more than: be less than than: than:
Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952 lbs. 19,750' 19.750"
R-Value Dimensions Framing Framing
2X4 29.2 29.4 R49 23.5 42.5 SF .753 lbs. 16.375' 16.375"
R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670lbs. 14.875" 14.875"
2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000"
2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375"
R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125' 9,125'
2x8 22.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7,750' '7,750'
2x4 20.4 20.6
R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750' 6.750"
2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750' 4.750"
2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 1 4.000" 4.000'
R-38 26 17.0 17.2 Bag HNwVA-Nmmmtl320s.,binlmm"31Ds.
2xB 16.7" 17.0 C-Iie and k,staaalkn daa were dd-bed WM a Volu-Adatc'II Mewing machine in it"gaswiU 13•gxa opera,2.0 psi Die pressor.and 15P of T nt-V-nugsm hose
This pmducl cvVm to me peMmance reauhemants WAST1A C 764.Type I.a^d rancefled Fedcd Spedfi ian RM-1e308,Typo I,Cow B.R--lees we de,emened in msadance wnh C 687 wd C 6%
2x4 13.2 13.3 •'R•means msbtarKe m twat Box The h+ha the R-vabe,ft rd.ew in.temgower ft m k R vaUo,p To get ed It Is essence Dial 6ds La on to Inst ied pmpey.a youdo nywrself,gM bs%c-
J M aid foaowthem rarafuey,Insimcbms do not cane wM this package.
R-3e 2x6 12,9 13.1
"Based on Thad Party 2-1 6ECEng 5".W rued setaement wer a 20-year pemd would to 1 cer=a a Im.This arn&A of seing is inc-Vit msignfcard.Treebm,e,e k,staW and seined
2x8 12.6 12.9 uddmessesareeflcelveyheacme.
2x4 11.3 11.4 %bkWzbc91is a raged trademark of Unisid
R-26 26 11.0 11.2 Builder's Insulation Statement
2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of...
2x4 9.3 9.5 R-Value Thickness
R-22 2x6 9.1 9.3 AtticArea R- at Inches
2x8 8.8 9.1 Sloped Ceilings R- at Inches
2x4 7.9 8.1 Walls R- at Inches
R-19 2x6 7.7 7.9 Floors(over an unheated crawl space) R- at Inches
2x8 7.4 7.7
2x4 5.3 5.4 Crawl Space Perimeter R- at Inches
R-13 2x6 5.0 5.2 Date Installed
2x8 4.8 5.0 Blowri4asu ation has been t Red in conformance with the above reco mend ti ns two,provide an R-value of:
2x4 4.3 4.4 R. '9C1 using_�bags of this insulation to cover�_square feet of area