HomeMy WebLinkAbout18-20410 CITY OF ZEPHYRHILLS
5335-STH STREET
(813)780-0020 20410
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION : LOCATION INFORMATION
Permit#:20410 ' Issued: 10/31/2018 Address: 3292 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 267,656.40 Total Fees: 17,872.97 Subdivision: HIDDEN RIVER
Amount Paid: 17,872.97 Date Paid: 10/31/2018 Parcel Number: 24-26-21-0100-00000-0910
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT
APPLICATION FEES
BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00
MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
b I �x 9
-0C/
Inspection Inspection4 Required
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CTORS §tit-NAtURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Lennar Homes-3292 Kresterbrooke Dr-2,376 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,482.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,145.00
TOTAL $ 2,145.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,272.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S : $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,872.97
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Thursday, November 1, 2018 4:49 PM
To: Jacqueline Boges
Subject: [Request received] 3292 Kresterbrooke Lane by#20410
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/248624
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
-- —' Nov 1 , 1 :48 PM MST
service 3292 Kresterbrooke Lane by#20410 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
mr
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: I` r
Site: Z�Z K BQsc�ro�'e La. ,
Permit Type: y c 2 ,3 70-5 `-
Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
2018182156
�ept: 661351-.— Rec: 10.00-- =
DS: 0.00 IT: 0.00
10/26/2018 L: S. , Dpty Clerk
PAULA S.0'IVEIL,PFi.D.Pg5C0 CLERK&_COMPTR0LEEh
106 19809
OR BK m PG 751
Permit No. Parcel ID No 24-26-21-0100-00000-0910
NOTICE OF COMMENCEMENT
state of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1.. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 91
Street Address: 3292 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence!Pool/Screen Enclosure/Fence
3. owner Information: Lennar Homes, L.L.C.
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(if other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813-574.5700
5. Surety: : N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT BUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION: IF YOU INTEND TO OBTAIN FINANCING,rONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office The foregoing instrument was acknowledged before me this 10 day of September ,by
Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for
Lennar Homes. LLC (name of party on be ment was executed).
Personally Known Z OR Produced Identification❑ Notary Signature
Type of Identification Produced Name(Print) Eli n
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that[.have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
..ELISSAM.HOLLERAN, Signature of Natural Person Signing Above
Gmmle9lon it FF 88583T
'off=ExpIres June 6,2010
wpdata/bcs/bcsform;. '"'''f. Dond14Thru7royFolnlMunneetOflai5Tetp
S AXE OF FLORIDA, COUNTY OF PASCO
THIS IS TO CERTIFY THAT THE FOREGOING IS A
TRUE AND CORRECT COPY OF THE DOCUMENT
In ycd"'h+e!'rite c ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
A WITN S MY HAND AND OF IC AL SEAL TM
PA LA S. 0' IL C ERK OMPTROL ER
��� OF ®�' BY _DEPUTY CLERK
PASCO COUNTY, FLORIDA
r
Permit No. ,_6 4t 0
Date Permitted _/n-2
Builder Name/Owner Name Wt wr<a�✓ trl'nS�.a< Control#
County Parce!No. ?_4-2-4-2.(,6(Ott--60LW-09 f t) SubDiv: 1 GIIdPn
Address/Location ZZcM beg J,J pk La,
Classification/Type of Use i/1�i k--7 T,k
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2, kV7
Exempt [] Yes ❑ No How Determined
Impact Fee Amount $..37 jz.(}� Zone No. TAZ:
SCHOOL IMPACT FEE qq Z$
Account (056) Single-Family Detached House Amount $ �, � ! t,
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes [] No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $
Exempt ❑ Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes ❑ No How Determined Total Amounen f `
RESOURCEFEE ERU
TOTAL AMOUNT
Prepared By �° �I^{'�— Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Lennar Homes 3292 Kresterbrooke Dr.-2,376 sq ft
Column
SQ. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - - $ 88.00
OTHER: - $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,487.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,150.00
Public Fee 1%
TOTAL $ 2,150.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,277.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,877.97
Single. Family Dwelling
Plan R&view Comments
1: F.F.E. shall be a minimum of 8" above.the road elevation and an engineered.site plan.
2. Lots shall be graded to comply with R401.3 of the R.C.
3. :Compaction.test required if 24" or more of fill dirt is.brought.in:at any.one place:
4: .Tie in-survey required,before pouring concrete.
5.. Driveways require a R.O.W. use permit. All 4 sides of driveway.thru the sidewalk shall have
expansion material:.
6. All setbacks.shall be met.
7.- All property markers shall be uncovered and marked.at time of first inspection:
8. All A.D.A:requirements shall be met. .
9. No:electric,plumbing, mechanical; or framing shall be:covered without an inspection.'and
approval first. .
10. All Garages shall comply with:section R302.6.of the.F.B.C.:(Fire Separation)..
11.Appliances shall not be installed in:a location where subject to mechanical damage unless
:protected by approved barriers. M303.4 of the F.B.0
12. Water heaters shall comply with section.P607.3 of the F.B.C.,
13. Foundation supports-for A/C.units §hall be raised at least 3" above finished grade, M 13-08.1 .:
14. Return air in all.bedrooms. F.B.C. M,1620.4.,
15. Smoke detectors are to be installed.in accordance with:R313:.1 of the F.B.C.
16; All glazing requirements are:to be in accordance with R308.4'of the F.B.C: .
I T All means of egress are to be in accordance with R311,of the F.B.0
18. `.`Green gypsum.boaid" shall riot be used as a backer in showers or tubs. R702.4.2:F.B.C.
19.'Combination-type AFCI breakers are,requited at all locations requiring an AFCI.type breaker:
20. Carbon monoxide alarins:will be required in new construction that uses-fossil-burning heating
or appliances or an attached garage,: They shall be,installed in accordance with-the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to.unit: This-includes all
underground plumbing and electric.
22. All 2016 N.E.C-. Codes:will be enforced.
23. Tamper- Resistant Receptacles'in accordance with 406.11 of the 2016 N.E:C .
24. In accordance-With the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25. Blower door test and blown in insulation card shall be provided before C.O.
26.A copy of the enemy cdcIs shall be with permit-at all tines.
27. Copy of final insulation report shall be.provided with.permit before.fenaL
.28:No fence; pool or screen enclosure is issued with this perniz
F.F.E.=Finished Floor Elevation
F.B.C- Florida Building Code Oh Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.=National Electric Code(2016)
24-26-21-0100-00000-0910 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, October 27, 2018
Parcel ID 24-26-21-0100-00000-0910 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $27,540
TAMPA FL 33607-4099 Building $0
Physical Address Extra.Features $0
3292 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540
Just Value $27,540
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 91 Taxable Value $27,540
OR 9799 PG 708
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001) _
Line Use DescriptionZ_oning Units Type--Price Coon Value
1� 1 100 SFR MPUD 6,000.00 SF $4.50 1.00-$27,000
2 0100 SFR MPUD 600.00 SF $0.90 1.00 I $540
_ Additional Land Information
`- — ---
Acres 0.15 Tax Area 3 F ME A 0ZH I Code Residential Code HDRVLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ Extra Features (Card: 001 of 001)
Line _ Des_cription _ { ear Units Value
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page Type_ _ D_OR Code Co- and tion Amount
_ 10/2018_ 9799 / 0708 Warranty Deed 05 Vacant Multi-Parcel Sale
09/2011 8606 / 3376 _ Warranty Deed 05 Vacant Multi-Parcel Sale
06/2010 8360 / 1872 Certificate of Title 12 Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126240100000000910 10/29/2018
81,3-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received SEP 13 2018 813 363 2891
Phone Contact for Permitting
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 a I 1 1 1 1 1
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 1
4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address I
N/A
JOB ADDRESS 3292 Kresterbrooke Lane LOT# 0910
SUBDIVISION Hidden River Phase One B PARCEL ID# 24-26-21-0100-00000-0910
r� I, (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED 11 11 NEW CONSTR E
ADD/ALT 0 SIGN Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR COMM OTHER
TYPE OF CONSTRUCTION BLOCK FRAME STEEL
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 2376-7 SQ FOOTAGE 1936 HEIGHT 1 Story
J BUILDING $ 1Z0 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE ® PROGRESSENERGY 0 W.R.E.C.
�• r
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
„OGAS 171 ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA DYES Do
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4600 W.C s St.Ste.2 ampa,FL 33607 CGC1518166
License#
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 1034 Skip Road, T pa, FL 33613 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5 , Bayonet,_EL 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5 , Bayone , L 30 34674-58 License# CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc
SIGNATURE REGISTERED Y/ N J FEE CURREN Y/N
Address 4211 Shoal&e Blvd, Spring Hill, FL 34607 License# CCC057991
� � � ttt � tttttttt ttttiiittttt � ttt � � ttttitttttttttttttttt � � ttt � tttitt
RESIDENTIAL Attach(2)Plot Plans; (2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days aftersubmittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
�.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions",
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor,shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned.
WARNING TO'OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN AITORNEY BEFORE RECORDING YOUR NOTICE OF CQMMENGKMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT 4K CONTRACTOR
Subscribed and sworn to(or affirm96Aefore me this Subscribed and sworn to(or affir d) efore me this
i u-pep-1 o by Ashlee Calla n 10-seP-1e by Ashlee Call a
Who is/are personally known to or hasihave pFed red Who is/are personally known to or
has/have pfedueed-
as identification. as identification.
r�o�
Notary Public Notary Public
Commission No. FF98537 Commission o. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped
- al[l;llq)��YhLl�11W
alw11.,pi�llli W' P' fan ntitifiia '
- ;yl�Rmltsamiippof�6tT' ��Ht�klr��d;�05d
2NOi�+l,n,Nrt ,wa�voA�e� +ii
SKETCH ONLY SEC. 24 , TWP. 26 S, RNG. 21 E.
PLOT PLJkN NOT A BOUNDARY SURVEY
LOT 9 1 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH, ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITTING PURPOSES LOT =_ 6600.00 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1556 _SQ. FT.
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 45 __SO. FT. M UNDERGROUND FOOTER, STEM WALL, AND
GARAGE = 407 —SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
LEGEND' COVERED LANAI = N/A Q. FT. SHOWN.
= PROPOSED DRAINAGE FLOW PATIO — 23 SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
CONC. DRIVE =_475 SQ. FT. w
(00.00) PROPOSED GRADE A/C & CONC PAD =_9____SQ. FT. ¢ NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE 6
PRIVATE SIDEWALK =_ 29 SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
NOTES' IMPERVIOUS =_ 39 % PAGE INDICATES THAT PLAT IS IN
—�2544 S
PROPOSED PAD ELEVATION Q. FT. PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = A SOD =__4051 _SQ. FT. CHANGE AND/OR REVISION.
=
FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
SIDE SETBACK = 10' RIGHT OF WAY =_720.00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 10' DRIVE APRON = 144 SQ. FT.
PUBLIC SIDEWALK =+240 Q. FT. STRUCTURE TIES SHOWN HEREON DENOTES
SOD =_336 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
TO PROPERTY LINE.
TOTALS * = 10' DRAINAGE/UTILITY EASEMENT
AREA =�7320.00 SQ. FT.
DRIVEWAY =_ 619 Q. FT.
SIDEWALK = 269 SQ. FT.
SOD =_092 SQ. FT.
�PRM(P)
N LOT 92 PLAT
BOUNDARY
�I
w 2 . o' ?. _ , ,,,v, S 89'36'58" E 1 10.00'_,_,,,,,,_
Z •, io o;
........I.29,67:....... :o
o:
ga,
O 24.50'
woo , , . ..' QD
Y¢w3 "w ^''.I '';: '.e:^.:' �w w LOT 324
xc�� cnZ�ao rn o
O° °4 ` I29.00' a rn �w I 1 HIDDEN RIVER PHASE ONE A
Q o N o a= ¢� o o cV (PLAT BOOK 74, PAGES 101-121)
w,�v 0 ........0I..:..... Of -10 w + O
Y r7 2 .50 a w 0
m Z m N
O
65'-0" a. O
20.50'..... .......24.50
O
:o A/c�:o
a N 89'36'58" W 1 10.00'�"�----,ram,
Y 92J RSA
BOUNDARY
LOT 90
00
ti
0
PROPOSED:
o LOWEST FLOOR ELEVATIONS:
3 LIVING AREA: 74.40'
DESCRIPTION: GARAGE AREA: 73.86'
ELEVATIONS REFERENCED TO
m LOT 91, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL
z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA
° OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
W
a
a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0460 D EFFECTIVE DATE: 9 30 1992
Project Number: Square Feet: 6600.00 t LENNAR HOMES
Z LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
T F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
m' PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
y REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
2 U P= UTILITY POLE, W F= WOOD FENCE
C JOHN R.BEACH&ASSOCIATES,INC. Drawn By:
SMS
SURVEYORS AND MAPPERS
°C 911 WEST ST. PETERSBURG DRIVE Checked By:
y ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
= 1"=30' Q
NOT VALID WITHOUT THE SIGNATURE AND [7a77LOT PLAN 8/16/18 ACS
o THE ORIGINAL RAISED SEAL OF A FLORIDA SIGNYME DAT
LICENSED SURVEYOR AND MAPPER JO R. CH
.fl
Revisions: F 0RIDA REG. ND SURVEYOR No. 2984 LB 4493
JEFF M. HART
�, ROF SURVEYOR & MAPPER No.7123
23 22 �j . 21 20 19 ! t 18 17 16 ii 15
'4 of
Fgg I WM. A:SE I FF:EL
0.40 irm M
IA L A A
A
........... ........... .. ............. ......... ..................... ....... .
"CHASt"P_RIYE
tr
All,
FF EL EL 93 1321 1FEJ A
Wo
I A 1 317 M8 .2
A
r——————————
EL 92 133 \Ts.'M/
A I
I Ft-9L
2 ig�m
8
EL
OW14 5A*
74AG
Ao
FFEL
283 'A
I FF FP
A
IF EL
135
4m
A 90
A
7am
26
EL kA
36
A
CM
A
— —— ———— FFEL I.
E E E
74AI
281
FFEL ,
A
r WFUL7
rF—F i p, 4
=A1
A 1 0
286W I
A
13 FEL FFEL 11 R
138 A' :Z-
87
I A I A LA
FrEL I
FF uj 27 711s
FF EL
MAU/ 415—
86
A
MA-
277
I FF EL'j
IFFIRL 278
0(11 FFF EL
V1,267
140
A"
... ........ .. .......................
.......................
1W DT
14
a— 84 M,
1 WE
316
t FF EL I
-M.
83 \r
NAW
LA4 2 8
FF
FFEL
FF EL
FFEL
71M
EL WAI A
40T
7 4 T-W/
FF MD
ffA,
143
A A 82
28
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0091
Project Name: 1941A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3292 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:J d 4/a
Owner: Lennar Homes Jurisdiction: 6412()9`(QJ1
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1119.8 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2
b.Frame-Wood,Adjacent R=11.0 307.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft') 1936 b.N/A R= ft2
Conditioned floor area below grade(ft') 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1936.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.68 PASS
Total Baseline Loads: 61.53
I hereby certify that the plans and specifications covered by Review of the plans and D�,TI�E ST,g�� '
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. f:. rrrrii�. . ;;: A,,,:``=� ,�0'
Dave AGol�r'cGc
PREPARED BY: Before construction is completed v
DATE: this building will be inspected for 0.
compliance with Section 553.908 * '
I hereby certify that this building,as design i Cin comp an g��yq Florida Statutes.
with the Florida Energy Code. C�
OWNER/AGENT: BUILDING OFFICIA
DATE: DATE:
- Compliance requires ce ' 'cation by the air handler unit manufacturer that the air handler en sure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0091
Project Name: 1941A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3292 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1719.8 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ft2
b.Frame-Wood,Adjacent R=11.0 307.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 sgft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1936.0 sgft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081
Total Proposed Modified Loads: 61.68 PASS
Total Baseline Loads: 61.53
I hereby certify that the plans and specifications covered by Review of the plans and ,OHE.STg?�
this calculation are in compliance with the Florida Energy specifications covered by this 1• ,�l `_ p,
Code. calculation indicates compliance rrj��ii, '% _= vp.
with the Florida Energy Code.
PREPARED BY: Dave A(. n� h Before construction is completed '
DATE: this building will be inspected for g
compliance with Section 553.908
I hereby certify that this building,as d ned, is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: need,
13 2018 BUILDING OF I
DATE: DATE:
- Compliance requires certi tion by the air handier unit manufacturer that the air handier closure qualifies as
certified factory-sealed in cordance with R403.3.2.1.
-Compliance requires an A Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0091
Project Name: 1941Al sf ADS Carrier Builder Name: Lennar Homes
Street: 3292 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) .9. Wall Types(1719.8 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1412.00 ftZ
b.Frame-Wood,Adjacent R=11.0 307.78 ftZ
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 4 d.N/A R= ftZ
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ftZ
6. Conditioned floor area above grade(ftZ) 1936 b.N/A R= ftZ
Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ
11.Ducts R ftZ
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ftZ
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ftZ
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftZ a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:.40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features
b.N/A R= ftZ None
c.N/A R= ftZ 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 61.68 PASS
Total Baseline Loads: 61.53
I hereby certify that the plans and specifications covered by Review of the plans and 0 '1 ST9?�
this calculation are in compliance with the Florida Energy specifications covered by this y_' Off,
Code. calculation indicates compliancefz
�a�eGol�icl� with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: this building will be inspected for O
compliance with Section 553.908
I hereby certify that this buildin as desi d, is in com liance Florida Statutes.
Y fY 9, pG,
with the Florida Energy Code. OD y�rg Y�
OWNER/AGENT: 13 2018 BUILDING O I
DATE: DATE: 6
- Compliance requires certi ation by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in ccordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 1941A1 sf ADS Carrier Bedrooms:: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1936 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: No County: Pasco
Jurisdiction: Whole House Fan: No City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1936 16360.3
SPACES
Number Name Area Volume Kitchen Occupants. Bedrooms InfilID Finished Cooled Heated
1 master 210 1680 No 2 1 1 Yes Yes Yes
2 family rm 341 3171.3 No 0 1 Yes Yes Yes
3 cafe 161 1288 No 0 1 Yes Yes Yes
4 kit 182 1692.6 Yes 0 1 Yes Yes Yes
5 -- bdrm2 147 1176 No 1 1 1 Yes Yes Yes
6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes
7 bath2 61 488 No 0 1 Yes Yes Yes
8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes
9 o wic 104 832 No 0 1 Yes Yes Yes
10 privy 24 192 No 0 1 Yes Yes Yes
11 o bath 117 936 No 0 1 Yes Yes Yes
12 laundry rm 100 800 No 0 1 Yes Yes Yes
13 foyer 148 1376.4 No 0 1 Yes Yes Yes
14 hall 43 344 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 e__ 0 0 1
2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 ____ 0 0 1
3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1
4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 e� 1 0 0
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value' Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 0 0 1
6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ftZ ____ 0 0 1
7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0
8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1
9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ftZ 0 0 1
10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 1 0 0
11Slab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0
12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 1 0 0
13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 -__ 1 0 0
14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 ____ 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 . 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1936 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood
2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood
3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood
4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood
5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood
6 Under Attic(Vented) bdrm3 ,30 Blown 149 ft2 0.1 Wood
7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood
8 Under Attic(Vented) 'bdrm4 30 Blown 149 ft2 0.1 Wood
9 Under Attic(Vented) 0 wic 30 Blown 104 ft2 0.1 Wood
10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood
11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood
12 Under Attic(Vented) laundry rm 30 Blown 100 ft2. 0.1 Wood
13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood
14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0
2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0
3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0
4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0
5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0
7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0
8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0
10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
13 N=>NE Garage Frame-Wood o wic 11 12 0 8 0 96.0 ft2 0 0.23 0.01 0
14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0
15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0
16 N=>NE Garage Frame-Wood laundry rm 11 7 5 8 0 59.3 ft2 0 0.23 0.01 0
_17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ftZ 0 0 0.6 0
18 W=>NW Garage Frame-Wood foyer 11 16 4 9 4 152.4 ft2 0 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft An
1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2
2 N=>NE Insulated foyer None .2 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
I/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 S=>SW 1 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None
2 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None
3 S=>SW 5 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in None None
4 E=>SE 71 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None
5 E=>SE 8 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None
6 N=>NE 10 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in 4 ft 2 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 416ft2 416f12 43.7ft 8ft 1
I
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R465-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000349 1772.4 97.3 182.99 .2641 6.5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 387.2 ft family rm 96.8 ftz Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb ki
Mar [ ]Apr [ I
May rl
Jun ri
Jul [X]Aug
Se r Oct [[ ]]Nov [[ ]]Dec
Heatin Jan Feb Mar [ ]Apr [ May Jun Jul [ ]Au Sep [ Oct [X]Nov [X]Dec
Ventin Jan Feb Mar [ i Apr [ May Jun Jul [ ]Aug Se [[[XXX Oct [X]Nov [ ]Dec
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 6
FOkM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78- 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 master
Default(8 Ibs/sq.ft. ft2 ft 0.3 family rm
Default(8 Ibs/sq.ft. ft2 ft 0.3 cafe
Default(8 Ibs/sq.ft. ft2 ft 0.3 kit
Default(8 Ibs/sq.ft. ft2 ft 0.3 bdrm2
Default(8 Ibs/sq.ft. ft2 ft .0.3 bdrm3
Default(8 lbs/sq.ft. ft2 ft 0.3 bath2
Default(8 Ibs/sq.ft. ft2 ft 0.3 bdrm4
Default(8 Ibs/sq.ft. ft2 ft 0.3 o wic
Default(8 Ibs/sq.ft. ft2 ft 0.3 privy
Default(8 Ibs/sq.ft. ft2 ft 0.3 o bath
Default(8 Ibs/sq.ft. ft2 ft 0.3 laundry rm
Default(8 Ibs/sq.ft. ft2 ft 0.3 foyer
Default(8 Ibs/sq.ft. ft2 ft 0.3 hall
Name: Signature:
Rating Compant: Date:
6/13/2018 1:36 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 6 of 6
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location AtticKamily rm
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13. Coaling system: Capacity 34.8
a)Split system SEER 15.0
5. Is this.a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6.Conditioned floor area(sq.ft.) 6. 1936 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a)U-factor:(weighted average) 7a. 0.551
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14. Heating system: Capacity 34.6
! c)Area 7c. 157.3 a)Split system heat pump HSPF 8.5
b)Single package heat pump HSPF
8.Skylights c) Electric resistance COP
a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised(R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10B1. 11.0
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed(Performance Method)
11. Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c)Knee walls/skylight walls 11 c. d) Multizone cooling credit
d)Radiant barrier installed 11 d. No e)Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in t ' ome before final inspection.Otherwise, a new EPL
display card will be completed based on installed c e compliant features.
Builder Signature: Date: 09/10/18
Address of New Home: 329 resterbrooke Lane City/FL Zip: FL Zephyrhi11s,FL 33540
6/13/2018 1:37:28 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Building Anal Job: 1941A1 sf ADS Carrier
g Y$I$ Date: 6113/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(7) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Walls 5.6 7036 25.5 acts
Glazing 30.2 4709 17.0 wall
Doors 23.5 466 1.7 nfiltration
Ceilings 1.3 2429 8.8
Floors 3.5 6726 24.3
Infiltration 2.1 3056 11.1
Ducts 3221 11.7
Piping 0 0 Glazing Floors
Humidification 0 0
Ventilation 0 0 D�Ceilings
Adjustments 0
Total 27641 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 3500 13.3 wall
Glazing 56.7 8852 33.7 Internal Gains
Doors 18.4 365 1.4
Ceilings 1.7 3358 12.8
Floors 0 0 0
Infiltration 0.5 684 2.6
Ducts 3628 13.8
Ventilation 0 0 Glazing Ducts
Internal gains 5915 22.5
Blower 0 0 Infiltration
Adjustments - 0
Total 26302 100.0 Other Ceilings
Latent Cooling Load=4180 Btuh
Overall U-value= 0.103 Btuh/ftz-°F
Data entries checked.
-rk =Ightsc ft- 2018-Jun-13 13:39:35
�. •�^a w- Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
i4CC1�...equipment\1941 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces: W
Project Summary Job: 1941A1 sf ADS Carrier
J ry Date: 6/13/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Notes: FBC 2017
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 'F Outside db 91 'F
Inside db 70 'F Inside db 75 'F
Design TD 39 'F Design TD 16 'F
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24421 Btuh Structure 22674 Btuh
Ducts 3221 Btuh Ducts 3628 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 27641 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26302 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3519 Btuh
Ducts 660 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1935 1936 Equipment latent load 4180 Btuh
Volume(ft') 16360 16360
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30482 Btuh
Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC536AO0300 Cond 25HBC536AO0300
AHRI ref 9155179 Coil FX4DNF037L
AHRI ref 9155179
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh
Heating output 34600 Btuh @ 470F Latent cooling 5220 Btuh
Temperature rise 26 'F Total cooling 34800 Btuh
Actual air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.86
Capacity balance point=26°F
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft` 2018-Jun-1313:39:35
� Right-suite®Universal 2018 18.0.16 RSU05714 Page 1
...equipment\1941 sf ADS template 3ton Carrier.rup Calc=MJB Front Door faces: W
Manual S Compliance Report Job: 1941A1 sf ADS Carrier
Date: 6113/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 26302 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.3°F Latent gain: 4180 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 30482 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Sensible capacity: 29580 Btuh 112% of load
Latent capacity: 5220 Btuh 125% of load
Total capacity: 34800 Btuh 114% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 27641 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Output capacity: 26331 Btuh 95% of load Capacity balance: 26 °F
Supplemental heat required: 1310 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
-�- wrightsoft®
2018-Jun-13 13:39:35
•re.mn..wu®,c— Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...equipment11941 sf ADS template 3ton Carrierrup Cale=MJ8 Front Door faces: W
PASCO COUNTY
PAS-C `� DEVELPMENT873O1 Citizen SEDriveRVI S Date:2/12/2019
COUNTY FLORID New Port Richey, FL 34654
,vr h u.ns. 727-847-2411
T A PERMIT
Receipt#: 1830303
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1427668 $60.30 $60.30 1830303 2/12/19
Waste Single Family
TOTALS: $66.30 $60.30
Receipt# Paid By Check# CC Auth#- Cashier ID Workstation -Receipt-Date Amt Paid
1830363 Check 1165458 8CCCP50W 02/12/2019 $60.30
Total Payments: $60.30
Pavor Address Phone
Lennar Homes, LLC /�
Comments:
v
3292 KFesterbrooke Lane
- ---- —While you will be paying your bill with Pasco County Development services,the full amount or the credit card or e•check fees;NOT shown above,is collected by - - - - -
First Billing payment services.
I
I
MyReports/reports//PASCOPROD/PASC0/ReceiptPOS_V6.rpt 2/12/2019 Page 1 of 1
' +1s m4 ,I
When Bulldings Talk.We Listen.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
CONSTRUCTION
Envelope Leakage Test_Report
Prescriptive and Performance Method
Project Name: J,oxlil P/ Builder Name: Z.eA1Ar42 14brAcx
Street: 32 92 Permit Office:
City, State,Zip: Gr,oxlye f,41el S' �� 33 540 Permit Number: Za i1!4
Design Location: Jurisdiction:
Square Feet: /q34 Conditioned Volume:
Envelo' pe Leakage Test Result
Single'Point Test Data:
HOUSE PRESSURE: —fib FLOW: gf
Leakage Characteristics
CFM (50): 19172
ffPass F]Fail
ACH(50): 3.3
R402.4.'i.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour in Climate Zones 1 and 2 ... Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50
Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Slatuies or individuals
licensed'as set forth in section 489A05(3)(f), (g), or(i)or an approved third party. A written report of the results of the test shall be
signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
9. Exterior windows and doors,fireplace and stove doors shall be closed, but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off:and
6.Supply and return registers,if installed at the time of the test,shall be fully open
hereby certify that the above envelope leakage Where required by the code official, testing shall be
)erformance results demonstrate compliance with conducted by an approved third-party. A written report of
=lorida Energy Code requirements in accordance with the test results shall be signed by the third parts
.ection R402.4.1.2.L conducting the test and provided to the code official.
19GNA URE: — zz:7� -
aRINTED NAME: Wit// BUILDING OFFICIAL:
?.ATE: MATE:
I
Jet Stream" Ultra Blowing Wool Insulation kNA1
Attic and C D
Cavity wall Card � ,::.=:•... . ,
.r��r � .,� r• fi fie »ve�e;�er� '
Batts and Blankets Equipment equired j
When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a conbgated hose with a minimum W inlemal corrugation,a minimum length
recommendations,Knauf Insulation balls and blankets will of 150'.Coils in the hose should not be less than X in diameter.Acceptable material feed rate is 5-35 ibslminute.Recommended feed E.
provide the full R value, rate is 15-25115s/minute.
R-Value* Minimum Thickness, Thermal Performance Sidewall and`Attic:Application)
4.' The stated thermal resistance(R-value)is provided by ioslailing in accordance with the manufacturers instructions,Failure to install the
1 To obtain an hli6lled insulation should required number of bags per 1,000 square feet and exceeding'the maximum square feet of coverage per bag as recommended by the label
insulation resistance not be less Than:
'R Yalue�oh will result in lower installed R-values.Field blending of this Proddc-Olh other 1005e tAll insulations is not recommended by the manufacturer, 11
M
Cavity Wall Bag Net,Weight-Nominal 32 lbs.,Minimum 31 lbs.; i
R-38HD 10.25"
i R-38 12.00' R-Value* Bags per 1000 SF. Maximum Net Minimum
R 30HD 8.Q5' To obtain an The number of bags Coverage per Bag Weight per SF 4
insulation per 1,000 square feet Contents of this The weight per square .
R-30 10.00, Cavity resistance of net area should not bag should not teat o1 installed insulation
R-26 9.OD" Framing Depth of: Density be less than: covermorethan: should not be less than: i
E R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs.
R-21HD 5.5Cr -7
2"x 6" 5t50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. i.
R 19 6.25°" 2•x 8" 7.25' R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs.
1 R-15HD 3.50"
R-13 3.50" .2"0 9.25' R-39 1.8 lbs./Cu'ft. 43.4 bags 23.1 sq.fl. 1.388 lbs.
- Il R-i 1 3.50" R means resistance to heat Cow.The higher the R-value,Vre greater the insulating power.To get the marked R-value,It is essential that Pds insulation De installed propedy.
R-8 .2.50. - _
"R-18 In a 5 5"cavity.C5"niorins to ASTM C 685 and Federal Open Attic Application Bag Net Weight-Nominal 32 lbs.,Minimum 31 Ibs.
III
Specdic6on HH-1-521F. I ..-k Minimum
Bags/ Maximum Minimum Initial Settled f
Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** It
To compensate for framing members,the number of bags per The number of bags/ Contents of this The weighu'sF Thickness Contents of this fi
1,000 sq-ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should I
To obtain an losulalion should not be less cover insulation should not should.not be less not cover more
Bags/MSF BagsIMSF
Joist 16'D.C. 24'O.C. resistance(R-Value)at: than: more than: .be less than than ,.: •than:
(
R-Value Dimensions Framing Framing
R-60 29.7' 33.6 SF .952 lbs. 19.75D',` 19.750" f,
_ ---
2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs: -- 16.375' 16.375' t
R-66 2x6 28.9 29.1 R44 20.9 47.8�F .676 lbs: 14.875 14.875"
2x8 28.6 28.9 R-38• 17.8 56.2 SF .569 lbs'. 13,000' 13.000" I
2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375' i
i R•49 2x6 22.7 22.9
- R-26 11.8 85.0 SF .3771bs. 9.125° 9.125" • ''
2x8 22.4 22.7 R-22 . 9.8 102.2 SF .313 lbs. 7.750' 7,750"
2x4 .20.4 20.6 i
i R•44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750' 6..750'..;
2x8 19.8 20.1 R-13,. ? 5.7 175.3 SF .183lbs. 4.750' 437 0
! 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 4.000"
R-38 2x6 17.0 17.2
f Bag Netweighh-Norrmol ML,Ihnn'ir,-31 b¢.. `
2X8 16.7 17.D Cove age eW ns a1atlM Y,a r�a de m A using a V&OAale II bbmg mafte n Nod gear n,th 13•pate opening,2.0 psi ar presnue ud 15C or 3-tntemaer<arw°xed hose.
This product contotmt'to Ne prlkm'inoe reTuvemena of ASTM C 764,Type I,and Car re FeWrd specdca%n Wi-1-10308,Tire 1,Class B.R-va5rs are de:emved in a=rdaue vian C 687 and C 51k
2x4 13.2 13.3 ,R* earns resisw"bheat eux Ire higher Ne R-v&e.Ne greater the nsuUmr poxes To get Ne marked Roue,s is essential Nat this MLAWn to Waged pt".a you do k ymuff,gas
tans aM Io"Inern caetu8l.BnsrudJttis do rrot come Vb this package.
R-30 2x6 12.9 13.1 "Based on Third Parry 21ea se*j�Wy Or Reftled settlement mera Mirear penod would be 1 percent or$-Rh amaad o'se&g is ten y ns+riY T ftbre.Ne nsh&d w w tled
2x8 12.6 12.9 tbkknessas are eCedxdy Ne same., r
2x4 11.3 11.4 vdlMare4lsaagsteeao- aiaaa
11-2s 2x6 11.0 11.2 Builder's Insulation Statement i
2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of.t.
2x4 9.3 9.5 R-Value Thickness
R-22 2x6 9.1 9.3 Attic Area R- at Inches i
2x8 8.8 9.1 Sloped Ceilings R- at Inches
2x4 7.9 8,1 Wails R- at Inches
R-19 24 7.7 7.9 Floors(over an unheated crawl space) R- at Inches
2x8 7.4 7.7
2x4 5.3 5.4 Crawl Space Perimeter R- at Inches
R-13 2x6 5.0 52 Date In
w f
2x8 4.8 5.0 Blown an�stgiation has been t lied in conformance with the above recom ndatio�ps�t9 provide an R value of:
2x4 4.3 4.4 R- (J using to- bags of this insulation to cover� I t square feet of area 4
R-11 2x6 4.1 4.3 at a minimum thickness of d f inches.
2x8 3.8 4.1
uk G.onmenl Insulation Contractor(signatu
GREENGVAl10 Gold'-
Kwuf Inwa a b,l&rg cv:'aan l i-e� Company DatP�`7 1
a lnEm'vowddG7.EEtY,,UA4DGaNdh .s d3 !
11lEttiawTetwtv3•.ibtixlana�rlasL•a-
Home6ciddei�sgl+aldre� ,