Loading...
HomeMy WebLinkAbout18-20414 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20414 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20414 Issued: 10/31/2018 Address: 2947 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER Amount Paid: 17,790.47 Date Paid: 10/31/2018 Parcel Number: 25-26-21-0100-00000-0590 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY HOME 2,276 SQ FT APPLICATION FEES BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 �P, r ©Gi/ sik 6�� fc;?{ Inspections-Re fired FOOT 2ND ROUGH PLUMB MI INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. O TRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-2947 Moulden Hollow Dr-2,276 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,790.47 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Thursday, November 1, 2018 4:52 PM To: Jacqueline Boges Subject: [Request received]2947 Moulden Hollow Dr by#20414 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephvrhillsfl.zendesk.com/hc/requests/248625 ....................................................................................................................................................................................................................................................................................................................................................................................... i' Jacqueline Boges --- ' Nov 1 , 1 :51 PM MST service 2947 Moulden Hollow Dr by#20414 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: r� I -� Site: 2- � 1 Abu ldeo Prb Ir ldl)`Jk Permit Type: ti 2 ?-ZG s Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) 20181.82153 Rcpt 2001351_ 10 ITeO0.00 00 DS: 0.00 10/26/2018 L. S. , Dpty Clerk F'HULH S.U`NE1L,-Pfi o-.-PHSCU'-CLERK"a/COMPTROLLEh 10OR BK 1�80gm PG 748 Permit No. Parcel ID No 25-26-21-0100-00000-0590 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 59 street Address: 2947 Moulden Hollow Drive Zephryhilis FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St, Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes_, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 10 day of September by Steve Robert Smith as Vice President (type of authorit r,trustee,attorney in fact)for Lennar Homes LLC (name of pa .non bh.1f. hom instrument was executed). Personally Known MEOR Produced Identification ElNotaryEnnat Type of Identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I deciare.thatJ have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. --�� " s ELISSAM,HOLLERAN Signature Natural Person Signing Above %� ;A C+mmlealon�FF 885031' 'a=ExPires'June 0,2020 wpdata/bcs/bcsform: DondNThruTroyFdnlMunnal00Ji5T01i1 STATE OF FLORIDA, COUNTY OF PASCU ®� THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT :n qo2?ve rrsr ON FILE OR OF PUBLIC RECORD IN THIS OFFICE r � .. WITNESS MY HAND A F I L SEAL THIS _�-DAY OF 2�1 ,' °' �` `• PAULA S. O'NEI ERK&COMPTROLLER a�aa �j� OF �®®�' QY DEPUTY CLERK .,. {PASCO COUNTY, FLORIDA " Permit No. f Date Permitted Builder Name/Owner Name �a? r- �T�r" S LIL C-- Control# County Parcel No.75—a(e-Z�—© 60 ( Q-1 S%SubDiv: lei o(de", Address/Location _Z1 T/ Ad Q(de-°i M l/ cb.*'" Classification/Type of Use t,�-Q ff- Aim"(C/ 2, 2-74 G� V 6— TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑ Yes ❑ No How Determined Impact Fee Amount " $. 31 �?2. ( Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 714 (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total tt Zone TOTAL AMOUNT $� ,Sto Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY jig _ A.-A, ' ��� ��•' �, Tj:�.:i"��''�t:•' a•�:.�';'•••, ..'� `'fir. . -'', ;J p ,i;:..., ii ter..`.• ••f.r+; •.�;._:�.� - Est...:•• _ '�i �.' •-. •. ._ _. t �t �'.t3L.: - - •. -v ..:`t•• t i i i i- i � . . t t� t i�! l i :� r�, ''3. .n`:: .... � ! t � m •erg. .i .,;..•"""": � �j�('y�'+.„x. _""`�",,,,,.�.. ..`y""'"w.+....,.,,,,i���.. ! i• � 'ja ��iqop� � 1��'r`� =7 S � t +w� cc) mt i I t Tf al Cb .. ... :oar'. ,ir .�' , � �•, � i �� � ! PLOT PLAN SKETCH ONLY : SEC. 25 , TWP. 26 S, RNG. 21 E. LOT 59 NOT A BOUNDARY SURVEY BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. }�j ON LOT AREA CALCULATIONS THIS SURVEY IS SUBJECT TO ANY FACTS THAT 1� LOT_ = 7996.74 Q. FT. MAY BE DISCLOSED BY A FULL AND ACCURATE LIVING AREA = 1838 __gQ, FT, TITLE SEARCH. ALSO SUBJECT TO SETBACKS, ENTRY = 32 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. o GARAGE = 306__SQ. FT. UNDERGROUND FOOTER, STEM WALL, AND ri COVERED LANAI =__N/_6 _SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR PATIO = 23 SQ. FT. SHOWN. CONC. DRIVE = 419 _SQ. FT. A/C & CONC PAD =_9 SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND PCP(P) a PRIVATE SIDEWALK = 72 _SQ. FT. NOTES TAKE PREFERENCE. RADIUS N IMPERVIOUS, = 35 —9 POINT = 2799 Q. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND SOD = 5198 SQ, FT, PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT To OFF LOT AREA CALCULATIONS CHANGE AND/OR REVISION. oo• M O U LD EN RIGHT OF WAY = 421.40 Q. FT. CERTAIN DATA SHOWN HEREON BASED ON DRIVE APRON = 145 S0. FT. ENGINEERING PLANS PROVIDED BY CLIENT. 4 HOLLOW PUBLIC SIDEWALK = 150 _SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES o�'.' DRIVE SOD = 126 _SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION HIDDEN RIVER PHASE ONE A TOTALS TO PROPERTY LINE. _ (PLAT BOOK 74, PAGES 101-121) AREA = 8418.14 SQ. FT. * = 10' DRAINAGE/UTILITY EASEMENT (R/W VARIES) DRIVEWAY = 564 SQ. FT. ** = 5' DRAINAGE EASEMENT SIDEWALK = 222 SQ. FT. SOD = 5324 _SQ. FT. PRELIMINARY DRAWING: " THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. 3: `C2S :'.:,.•'...:'. ? :r LEGEND: N ass PLAT ww—= PROPOSED DRAINAGE FLOW "N;� ?2J BOUNDARY (00.00) = PROPOSED GRADE '",. :`v h• �N• E-00.00 = EXISTING GRADE NOTES: •'ie.00 LOT GRADING TYPE = A 'f� PROPOSED PAD ELEVATION = LOT 58 \ / FRONT SETBACK = 20' SIDE SETBACK = 10' o REAR SETBACK = 10' P�PLAN f 0 i 0.00' 91 EL AG'B1'• W LOT 60 GAR LEFT f =_ LOT 59 40', . O •' A/C 23.24'....... \ :'ry PATIO ..... :N rn \ O Cs7 \ PLAT BOUNDARY PLAT TRACT "B" \ BOUNDARY WEfIAND CONSERVATION AREA/ DRAINAGE EASEMENT PROPOSED: HIDDEN RIVER PHASE ONE A LOWEST FLOOR ELEVATIONS: (PLAT BOOK 74, PAGES 101-121) \ WETLAND ACONNSERVATION LIVING AREA: 71.75' GARAGE AREA: 71.21' m ELEVATIONS REFERENCED TO \ NATIONAL GEODETIC VERTICAL n DATUM OF 1929. MEAN SEA N -\ LEVEL= 00.00 FT. DESCRIPTION: �i� LOT 59, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE 1JO \ B", AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH m Q . 082, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Z CURVE RADIUS ARC CHORD BEARING DELTA O C28 63.00' 1 38.81' 1 38.20' 1 S 78-08.03" E 1 35-17.56- w U57 1 173.00 106.58' 1 104.90 1 N 78'08.03" W 1 35-17.56" a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9 30 1992 Project Number:cc Square Feet: 7996.74 t LENNAR HOMES _4 LEGEND: 0 (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= a CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, m= F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT aw REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE W F= WOOD FENCE Cx JOHN R.BEACH&ASSOCIATES,INC. Drown By: SMS SURVEYORS AND MAPPERS hec 911 WEST ST. PETERSBURG DRIVE Checked By: ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 8/27/18 ACS 2 THE ORIGINAL RAISED SEAL OF A FLORIDA NA QE5 LICENSED SURVEYOR AND MAPPER -0 Revisions: FLORIDJOHN AD SURVEYOR No. 2984 LB 4493 i JEFF M. HARILW SURVEYOR & MAPPER No.7123 Lennar Homes 2947 Moulden Hollow Dr:2,276 sq ft Column Es SQ. FEET PRICE - MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 Public Fee 1% TOTAL $ 2,067.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - i FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,194.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ -3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,795.47 25-26-21-0100-00000-0590 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, October 27, 2018 Parcel ID 25-26-21-0100-00000-0590 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $30,297 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 2947 MOULDEN HOLLOW DRIVE ZEPHYRHILLS, FL 33540 Just Value $30,297 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $30,297 See Plat for this Subdivision Taxable Value $30,297 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 59 OR 9799 PG 708 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use DescriptionZoning Units Type Condition alue 1 0100 SFR __ MPUD 6,000.00 SF $4.75 _ 1.00 $28,500 2 0100 SFR MPUD 1,997.00 SF F $0.90 1.00 $1,797 Additional Land Information _ Acres . 0.18 Tax Areal 30ZH Code -- Residential Code HDRVCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line Description Year Units lValue No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page `Type IDOR Code Condition ,Amount 10/2018 9799 / 0708 Warranty Deed 05 Vacant Multi-Parcel Sale 09/2011 8606 / 3376 _ Warranty Deed 05 Vacant_ Multi-Parcel Sale 06/2010 I 8360 / 1872 Certificate of Title 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126250100000000590 10/29/2018 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received SEP 13 2010 phone Contact for Permitting 813 363 __ 2891 1 1 1 1 1 1 1 1 1 1 1 1 Owner's Name Lennar Homes,LLC Owner Phone Numberr8l .574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 2947 Moulden Hollow Drive LOT# 0590 SUBDIVISION Hidden River Phase One B PARCEL ID# 25-26-21-0100-00000-0590 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED 11■/ II NEW CONSTR e ADD/ALT 0 SIGN Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION BLOCK FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2276 SQ FOOTAGE 1817 HEIGHT 1 Story BUILDING $ ! VALUATION OF TOTAL CONSTRUCTION (ELECTRICAL $oC AMP SERVICE ® PROGRESS ENERGY W.R.E.C. PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do . BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 4600 W.C ress St.Ste,, ,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 SkEVer Ro d, mpa, FL 33613 License# I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 08, BayqA<FL 34674-5308 License# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 8, Bayo FL 34674-5308 License# AAC058062 OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y=N Address 4211 Sho Ine Blvd, Spring Hill, FL 34607 License# 1 CCC057991 11111111111111 1111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ■ . . Directions:■ Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned und'e'rstands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells,-Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W" unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. -FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affir )before me this Subscribed and sworn to armed)before me this r u-0eP-1 o by Ashlee Calla 1osep-1a by As allahan Who is/are personally known t me or h^ Who is/are ersonall own to me or as identification. as identification. Notary Public Commiss Notary Public Commission No. FF98537 ion No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped .' yll'�te�n`aa"ami.ppPb�l44� I ����ur;1A;�N� ���•�4d',�hl��'�Ci�9 � B�a�++l'�wr�ay�otU�waa�lttul�+l1 • , BatdlltilN'I'�Pi%at411�id;�,1�'�II - - Single ami Y we ing: Plan Review Comments 1: F.F.E. shall be a minimum of 8" above.the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction.test required.:if24"or more of fill dirt is brought in.at any one place: .4. Tie in.survey required before pouring concrete.. 5. Driveways.require a R:O:W. use permit: All,_4 sides of driveway thra the sidewalk shall have expansion material:. 6. All setbacks-shall be met.: 7. All property markers shall be uncovered and in. at time of first inspection: 8. All A.D.A:requirements shall be met.. . 9. No electric`plumbing,.mechanical�.or frainirig shall be.covered without an.inspection_and - . g� . . . . . - : . .. approval first.:.. 10.All Garages shall,comply,with:section R302:6 of the:F.B.C:_(Fire Separation).: I L.Appliances shall not:be installed in:a location where subjectto mechanical'damage unless protected'by approved,barriers. .M303.4 of the F.B.0 12. Water heaters shall comply:with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall be raised at least 37 above finished grade, M1308,1 - 14. Return air in all.bedrooms..F.B.C. .M1620.4, - : 15. Smoke detectors are to be installed i ' accordance.witli R313:1 of the F.B.C. 16. All glazing requirements are.to be in accordance with R308.4 of the F.B.C. 17. All means.of egress are to:be in accordance.with R31 l:of the F:B.C.- .: 18. "Green gypsum board shall not be-used-as a backer in:showers or tubs. R702.4.2.F.B.C. 19..Combination-type AFCI breakers.are required,at all.locations requiring an AFCI.type breaker: 20. Catbon monoxide alarms:will be required m-new:construction that uses-fossil-burning heating :or appliances or an attached garage.:. They shall be,installed'in accordance with.the F.B.C: 21. All plumbing, mechanical,:and.electrical shall be separate from unit to:unit: This includes all underground plumbing and electric. 22. A11201-6 N.E.C. Codes will be enforced. 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C 24. In accordance:.with the Land Developmeiit:Code,lots shall be§odd-ed'before final at least 10_ feet around the structure. : . 25. Blower door test and blown in insulation card shall be provided before C.O. 26.A copy of the energy cdclsshall be with permit.at all times.. 27. Copy of final insulation report shall be.provided,with:perjnit before:rnal . 28:No fence;pool or screen enclosure is issued with this Permit- F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) p FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791 B1 sf ADS Carrier Builder Name: Lennar Homes 0059 Street: 2947 Moulden Hollow Drive Permit office: City of Ze hyrhills City,State,Zip: FL, Permit Number: Zd ff/W Owner: Lennar Homes Jurisdiction:- XT21*6/64-�) Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft' 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 - 87.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None -c.N/A R= ft2 15.Credits, Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 57.78 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this �' = ., p Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Aun h Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as des'PSEP is i mpliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: 1 3 20�� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certi ication by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 s FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 17911131 sf ADS Carrier Builder Name: Lennar Homes 0059 Street: 2947 Moulden Hollow Drive Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2. 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 57.78 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this a p Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave >'flo nM Before construction is completed DATE: this building will be inspected for 0: - y compliance with Section 553.908 I herebycertify that this building,as desi ned, ' com liance Florida Statutes. fY 9, 9 P Affty with the Florida Energy Code. OD yj►g 4� OWNER/AGENT: S�� 3 2010 BUILDING OFFICIAL: VLO-r-c ('Q'� DATE: DATE: - Compliance requires cert ication by the air handler unit manufacturer that the air handler 04closure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation = Residential Performance Method Project Name: 11791131 sf ADS Carrier Builder Name: Lennar Homes 0059 ; Street: 2947 Moulden Hollow Drive Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ b.Frame-Wood,Adjacent R=11.0 331.33 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ftZ 6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ftZ. Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ftZ SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ftZ SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.323 14.Hot water systems 8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 57.78 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave AGo HM Before construction is completed DATE: this building will be inspected for 0 -'11��. compliance with Section 553.908 * tr I herebycertify that this building,as desi ned, i om liance Florida Statutes. fY 9, pC-. �� with the Florida Energy Code. OWNER/AGENT: SEP 1 2018 BUILDING OFFICIAL: DATE: DATE: - Compliance requires certi -tion by the air handler unit manufacturer that the air handler closure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 1791 B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 ' Medium BLOCKS Number Name Area Volume 1 Blocki 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip" Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood 7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space CavR_Vaity Width Height Sheathing Framing Solar Below ypp 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0.23 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ftZ 0.23 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 23.0 ft2 1 ft 0 in 4 ft 2 in Drapes/blinds None 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.58 0.32 N 33.3 ft' 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 . Wholehouse Proposed ACH(50) .000305 1453.6 79.8 150.08 .227 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1 7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb ]Mar A r Ma X Jun X Jul ri Au Se Oct Nov Dec Heating HJan Feb �X]Mar APr May Jun f Jul Au �Xj SeP f Oct X Nov Dec Ventin Jan Feb [ki Mar [X A r [ Ma [ Jun [ Jul Aug Se [X Oct [X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 Main Name: Signature: Rating Compant: Date: 7/25/2018 8:25 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 •2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4.Number of bedrooms 4. 4 13.Cooling system: Capacity 28.4 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1817 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.553 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14. Heating system: Capacity 28.2 c)Area 7c. 143.3 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c)Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 1082. 16. HVAC credits claimed (Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a)Under attic 11a. 30.0 b) Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. d)Multizone cooling credit d)Radiant barrier installed 11 d. No e)Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be completed based on insta ed code pliant features. Builder Signature: Date: 09/10/18 Address of New Home: 29474oden Hollow Drive City/FL Zip: FL Ze12hyrhi11s,FL 33540 7/25/2018 8:26:24 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 1 Building Analysis Job: 1791B1sf ADS Carrier Y Date: 9110/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: ! Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 5.2 7792 28.9 Ducts Glazing 30.2 4772 17.7 Wall nfiltration Doors 23.5 466 1.7 Ceilings 1.3 2271 8.4 Floors 3.4 6125 22.8 Infiltration 1.7 2882 10.7 Ducts 2616 9.7 Floors Piping 0 0 Humidification 0 0 Glazing Ventilation 0 0 other Ceilings Adjustments 0 Total 1 1 26924 100.0 Component Btuh/ftZ Btuh % of load Walls 2.8 4159 18.3 Internal Gains Glazing 48.7 7697 33.9 walls Doors 18.4 365 1.6 Ceilings 1.7 3140 13.8 Floors 0 0 0 ucts Infiltration 0.4 645 2.8 Ducts 2982 13.1 Ventilation 0 0 Internal 'gains 3750 16.5 Infiltration Blower 0 0 Glazing Adjustments 0 Ceilings Total 22738 100.0 Other Latent Cooling Load=2873 Btuh Overall U-value= 0.103 Btuh/ftZ-°F Data entries checked. -Pk- =Vghtspft- 2018-Sep-10 14:41:28 °W.• wN- Right-Suite®Universal2018 18.0.16 RSU05714 Page 1 A'Ck ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces: N Project SL1111t17a Job: 1791B1 sf ADS Carrier Summary Date: 9110/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 of Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 24308 Btuh Structure 19756 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 26924 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22738 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2339 Btuh Ducts 534 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft') 1817 1817 Equipment latent load 2873 Btuh Volume(ft') 15431 15431 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 25611 Btuh Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC53OA00300 Cond 25HBC53OA00300 AHRI ref 9154945 Coil FX4DNF031L AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24140 Btuh Heating output 28200 Btuh @ 47°F Latent cooling 4260 Btuh Temperature rise 26 °F Total cooling 28400 Btuh Actual air flow 1000 cfm Actual air flow 1000 Cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 31 °F Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightscx t- 2018-Sep-1014:41:28 - - ---m Right-Suite®Universal 2018 18.0.16 RSU05714 Pagel ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: 1791B1 sf ADS Carrier Date: 911012018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions ,Outdoor design DB: 91.3°F Sensible gain: 22738 Btuh Entering coil DB: 75.7°F 'Outdoor design WB: 77.3°F Latent gain: 2873 Btuh Entering coil WB: 62.87 Indoor design DB: 75.0°F Total gain: 25611 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Sensible capacity: 24140 Btuh 106% of load Latent capacity: 4260 Btuh 148% of load Total capacity: 28400 Btuh 111% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 26924 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Output capacity: 22528 Btuh 84% of load Capacity balance: 31 °F Supplemental heat required: 4396 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. wrightsoft- 2018-Sep-10 14:41:28 AEC .ua.,•rmem wu�,�.� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJe Front Door faces: N PASCO COUNTY DEVELOPMENT SEIRVICES PAS C 8731 Citizens Drive Date:2/11/2019 COUNTY FLORIDAIkOr- New Port Richey,FL 34654 (.)Ilr,4 SPAU-S,I'MRANT PLAGUb. 727-847-2411 WC)IT A PERMT ah Receipt#: 1830068 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEEAMOUNT PAID, RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1427391 $60.30 $60.30 1830068 2111/19 Waste Single Family TOTALS: $60.30 $60.30 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Recelpj Date Amt Paid 1830068 Check 1155450 BCCCP69W 02/11/2019 $60.30 Total Payments., $60.30 Payor Address Phone nnar Homes,LLC Comments: V 2947 Moulden Hollow DR while you will be paying your bill with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS—V6,rpt 2/11/2019 Page 1 of 1