HomeMy WebLinkAbout18-20428 CITY OF ZEPHYRHILLS
5335-STH STREET
(813)750-0020 20428
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20428 Issued: 11/05/2018 Address: 35989 SADDLE PALM WAY
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 364,084.80 Total Fees: 15,026.70 Subdivision: SILVERADO
Amount Paid: 15,026.70 Date Paid: 11/05/2018 Parcel Number: 04-26-21-0080-00500-0140
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,232 SQ FT
APPLICATION FEES
BUILDING FEE 1,977.30 ELECTRICAL FEE 419.63 PLUMBING FEE 279.75
MECHANICAL FEE 195.83 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
3
Inspections Re uired
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
RAC"TO RS S I kGN t U R E PERMIT OFFIjFA
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
04-26-21-0080-00500-0140 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, November 3, 2018
Parcel ID 04-26-21-0080-00500-0140 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $27,268
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
35989 SADDLE PALM WAY
ZEPHYRHILLS, FL 33541
Just Value $27,268
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,268
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $27,268
BLOCK 5
LOT 14
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line {Use !Description;Zoning !Units -;Type .Price ;Condition ;Value
1 0100 { SFR MPUD 6,000.00 ; SF $4.40 1.00 ! $26,400
2 i 0100 j SFR MPUD 2,169.00 I SF $0.40 ; 1.00 $868
Additional Land Information
FEMA j
Acres 0.19 .Tax Areaf 30SI Code -- Residential Code I SLVRCPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line ;Description Year ;Units ;Value
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year;Book/Page Type DOR Code Condition'Amount
10/2018 ! 9811 / 1078 Warranty Deed i 05 Vacant !Multi-Parcel Sale
05/2017 9535 / 0546 Certificate of Title 05 Vacant Multi-Parcel Sale
11/2016 j9462 / 0384 Mineral Rights or Royalty Transfer; 05 Vacant !Multi-Parcel Sale
http://search.pascopa.com/parcel.aspx?parcel=2126040080005000140 11/5/2018
Lennar Homes-35989 Saddle Palm Way-3,232 Sqft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 3,232 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 364,084.80
FEE SHEET $ 1,865.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,982.30
ELECTRICAL: $ 419.63
PLUMBING: $ 279.75
MECHANICAL: $ 195.83
SUB-TOTAL $ 2,877.50
Public Fee 1%
TOTAL $ 2,877.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 3,430.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,031.69
Single Family.Dwelling ;
Plan Review Coinments
1: F.F.E. shall be a.minimum.of 8".above.the road elevation-and an' engineered site.plan.
2.. Lots shall be graded.to comply with R401.3 of the-F.B.C.
3. .Compaction test required if 24 or more.of fill dirt is brought in at any one place.
4.. :Tie in survey-required before pouring concrete.
5. Driveways require a R.O.W. use permit: All sides of driveway thru the sidewalk shall Have
- expansion material...
6.. All setbacks.shall be met.; .
7. Ali.property markersshall be,uncovered and marked at time of first inspection:
8. .All A.D.A.requirements shall be met. .
9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and
approval first.
10. All Garages shall-comply;.with:section R302.6 of the F.B.C.-(Fire Separation)..
11.Appliances shall not be installed in.a location where subject to mechanical'damage:unless.
protected by approved barriers. M303..4'of the F.B:C
12. Water heaters shall comply.with section.P607.3 of the F.B.C.
13. Foundation supports-for A/C-units shall be raised at least 3" above finished grade. M1308.1.
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be 'installed in accordance with R313:.1 of the:F.B.C.
16::All glazing requirements-are to be in accordance with R308.4.of the F.B.C. .
17. All means.of egress are to be in,accordance,with R311:of the F:B.0 .:
18. `.`Green gypsum board"shall not be used.as.a backer in:showers or tubs. R702.4.2.F.B.C:
19. Combination-type AFCI breakers are required:at all.locations requiring an AFCI,type breaker:
20: Carbori monoxide alarms will be required in.riew:construction that uses fossil-burning:heating
or appliances or an attached garage.:-,They shall be-installed in accordance with the F.B.C:
21. All plumbing,mechanical,:and-electrical shall.be separate from unit to unit: fihis includes all
underground plumbing and electric.
22. All 2016 ME.C. Codes-Will be enforced..
23. -Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 ME:C .
24. In accordance.with the Land:.Development:Code;lots shall be sodded before final at least 10 . . .
feet around the structure.
25. Blower door test and blown in insulation card shall be provided before CO .
26 A coprof the enerzy cacls.shall be with permit at all times.:
27..-Copy of final insulation-report shall be provided with:permit before:finab .
F.F.E.=Finished Floor Elevation
F.B.C-Florida Building Code 6ffi Edition.
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011)
Lennar Homes-35989 Saddle Palm Way 3,232 sq ft Single Family
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 3,232 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 364,084.80
FEE SHEET $ 1,865.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,977.30
ELECTRICAL: $ 419.63
PLUMBING: $ 279.75
MECHANICAL: $ 195.83
SUB-TOTAL $ 2,872.50
TOTAL $ 2,872.50
SEWER:
WATER:
IRRIGATION: $, -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 3,425.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ '71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,026.69
PASCO COUNTY, FLORIDA
Permit No. 2—0 M
Date Permitted l 5—!
Builder Name/Owner Name "vt o_�- _ _ ne.,A !_ Control#'
County Parcel No. 0�_ _2 f_IS(�°t�-�(X�SC)O—I)/ Vo SubDiv: S)1 VP raL10
Address/Location 81 dal w9-
Classification/Type of Use �4Vkq le 3 23Z 3 7 Z
TRANSPORTATION IMPACT FEE Rate: Sq Ft Unit: 3,Z3z
Exempt [] Yes ❑ No How Determined
Impact Fee Amount $. ,(032.6t� Zone No. TAZ:
SCHOOL IMPACT FEE p
Account (056) Single-Family Detached House Amount $ 74 �9
(057) Mobile Home
(058) Other Residential
123 Collection Fee
Exempt F�Yes ❑No How Determined
PARKS AND RECREATION FEE
i
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 7
Exempt ❑Yes ❑ No How Determined
I
j LIBRARY FEE
iLand Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes [:] No How Determined Total Amoun
i
RESOURCE FEE ERU
j TOTAL AMOUNT
Prepared By Checked By
0.
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
PASCO COUNTY
DEVELOPMENT SERVICES'
PASG'', 8731 CitizensZrive -Dates2/12/2019
COUNTY FLORID New_ Port Richey;FL 34'654.
ri,•,. , 4r1,.17 727-847-2411
Receipt#: 1880340
FEE.DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID. RECEIPT# DATE
impact Fee ResidentialiSolid 24503100=329010 1.00 1427711 `$60.30 +$60.30, 1830340 2/12%19
Waste Ingle Family
TOTALS:, $66.:b $60.3.0,
Receipt Paid By Check#. CC Auth# 'Cashier ID workstation. Receipt.Date� Amt Paid
%'30340 Check 1155467 BCCCP59W 02/12/2019 360;30
Total Payments: $60:40
Pavor Address Phone
Lennar Homes,LLC
Comments:_35.989,Saddle Palm Way
---Whlle'you'tvill be paying your bill wlih'Pasco County.Developmenf Ser4ices;the full amouM0'f the credit card'or e-check-fees„NOT shown abb a is collected by-------------------- -----------
Hai fillling payment services,
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6.rpt 2/12/2019 Page-1 of 1
a
f�� I:L'O IIIUP-
1
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: �\� C(�✓ �
Date Received: / r
Site: r
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
(e.D
This comment sheet shall be kept with the permit and/or plans.
Kalvin Swi 'er—P1 Examiner Date C ac or Homeowner
(Required when comments are present)
�� i I�iNI lilll lllii lll�l iIIII IIiII IIIII II��I IIiII IIIII INl llll
2018184339
Rcpt:2002464 Rec: 10.00
IDS: 0.00 IT: 0.00
10/31/2018 K. S. , Dpty Clerk
`PAULA S.O'NEIL,Ph.D.pASCO CLERK f CiMPTROLLER
10103118201 "` PG 386
Permit No. Parcel ID No 04-26-21-0080-00500-0140
NOTICE OF COMMENCEMENT
state of . Florida County of PaSCO-
THE UNDERSIGNED hereby gives_notice that improvement will be made to.certain real property,.and in accordance with Chapter 713,Florida Statutes,
the.foliowing information:is provided in this Notice of-Commencement:
1. Description of Property: Legal"SILVERADO RANCH SUBDIVISION PHASES 6"8&9A PB 75 PG-75 BLOCK 05"LOT 14
Street.Address: 35989 Saddle-Palm.Way zephryhilis FL 33541"
2. General Description of.lmprovement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lennar,Homes,LLC:
Name "
4600 W Cypress St. Ste 200 Tampa F 33607
Address City State
Interest in Property:
Name of.Fee Simple Titleholder:" N/A
(if other than owner)
Address City State,
4. Contractor: Lennar Homes, LLC,
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607.
Address City State
Contractor's.Telephone.No.: 813.574.5700
5. surety: :: N/A
Name
Address City State
Amount of Bond: $ Telephone.No,:
6. Lender: 'NIA
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by .
Section 713.13(1)(a)(7),Florida Statutes:
Letinar Homes."LLC
Name
4600 W Cypress St, Ste 200 . Tampa FL, 33607`
AddressCity State'
Telephone Number of Designated Person: 813.574.5700
8.. In addition-to himself,the owner designates N/A of
to receive a copy of the Lienor's-Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is oneyear from the-date of recording unless a different date is specified:
WARNING TO.OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER. PAYMENTS UNDER CHARTER 713,-.PART.1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING"TWICE FOR IMPROVEMENTS"TO YOUR.PROPERTY. A NOTICE-OF'COMMENCEMENT.MUST BE
RECORDED AND POSTED*ON THE JOB.SITE BEFORE THE FIRST INSPECTION. IF.YOU INTEND TO OBTAIN FINANCING,CONSULT..
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE"OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Sigh ure of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The-foregoing instrument was acknowledged before me'this 14 day of August by
Steve-Robert Smith as:•Vice President (type of atithori .stee,attorney in fact)for
Lennar Homes LLC. (name of party o b !'.whom instrument was executed).
Personally Known®OR Produced Identification[I Notary Signature G.
Type of Identification Produced Name(Print) EIISsa Holleran
Verification,pursuant.to Section.92.525,.Flodcla Statutes. Under penalties of perjury,I declare:that l have read the foregoing and that.the facts stated in,
it are true to the best of my knowledge and belief.
EGB.SAM;HCU.ERAN Signature of Natural Person Signing Above
CoMlIS101 MFF98583r
"=EaplrusJune ,2020
wpdata/bcs/bcsform;, $. � ttoridMlhN7royFglnln>Iunnce1003Pgypip
- i
813-780-0020 City of Zephyrhills Permit'Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting 813 363 _ 2891
1 1 1 1 1 1 .p t 1 1 .1 .1•.1
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's.Address 4600 W.Cypress St.Ste.200,Tampa;FL 33607 Owner Phone Number
Fee Simple Titleholder Name N/A / Y Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 35989 Saddle-Palm Way LOT#
0140
SUBDIVISION Silverado Ranch Subdivision Ph 6,8,9A PARCEL ID# 04-26-21-0080-00500-0140
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II✓ II NEW CONSTR B ADD/ALT SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR Q COMM = OTHER
TYPE OF CONSTRUCTION BLOCK 0 FRAME = STEEL =
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 3239 SQ FOOTAGE 2443 HEIGHT 1 1 StOry
✓ BUILDING $ VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ ® PROGRESS ENERGY Q W.R.E.C,
AMP SERVICE
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING = SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES I IVO
II__II'
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W,Cypress St.Ste, ,Tampa,FL 33607 License# CGC1518166
ELECTRICIAN COMPANY =Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 1034 Skipper Road,X-M
pa, FL 33613 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE / REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayo t, FL 346 -5308 License# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &.AC; Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 34 -5308 License.# I CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4211 Shoal Line.Blvd, SpAng Hill, FL 34607 License# C66057991
Itlllllll-111111111111111111111 .111111111111111.11 .111111111111111 .111•I1
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety.Page;(1)set of Energy Forms.R-O-W Permit for new construction.-.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction..
u
Directions:
Fill out.application completely.
Owner&Contractor.sign back of application,notarized
If over$2500,'a Notice-of Commencement is required. (A/C upgrades over$7500) --
** Agent(for the contractor)or Power-of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of.contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW - -
`
'
.
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
vn/icn oe more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
`applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired' o contractor or
contractors to undertake work�they may be required-to be licensed in accordance with state and local regulations. If the
contractor isnot licensed as re quired by law, both-,
nd contractor may be
work,under state' law. 'if the owner or intended contractor are, uncertain as,.to W* hat licensing requirements may apply,for ti-e-,
intended they—` pre advised-- to contact— the.Pasco County— Building— Inspection� � Division—Licensing Section at 72284'
8�. Furthermore, if the owner has hired a contractor or ���� �,,advised to have the sign-
portions of the "contractor Block uf this application for which they will be responsible. Ifyou.-aatheovvnerokJn as the
contractor, that may be an indication-that he is not property licensed and is not efititled to permitting.privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The
' undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction
90-07, as amended, The use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
undersigned , that such fees, as may be due, will be identified a
t the time of
permitting. 'it ha further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving o "oertificateof occupancy" or final power release. |f the project does not involve a certificate of occupancy r
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must bepaid prior to permit issuance in accordance with applicable Pasco County ordinances. '
CONSTRUCTION�LIEN LAW(Chapter 713,Flprida Statutes, mmenmeodmd)- |fwa|umtionof work ia$2.5OD.O0ormore, | �
certify that |, tha opp|icant, have been provided with e copy, of the Florida, Construction. Lien Law—Homeowner's '
Protection Guide" pnaponad by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone .
other than the"owner", I certify'that I have obtained a copy of the above described document and promise in good faith to '
deliver itto the"mwner"prior tncommenuement`
CO0TFACTORyS/OVV0ERIS AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in-nomp|iaAoa with all-applicable laws regulating uonntruction, zoning and land development. Application is
hereby mode to obtain o pe rmit to do work and installation as indicedad. | madhy that no work or installation has
commenced prior to issuance of permit and that all work will be performed to meet standards of all. laws regulating
oonotruction. County and City Codas' zoning regulations, and land development regulations in the jurisdiction. | also
certify thsd | understand that the regulations of other government agencies may apply tVthe intended work, and that it is
my responsibility to identify what actions | must take tobeincompliance. Such agencies include but are not limited to:
- Department.ofEnvironmental Protection-Cypress Beyheado. Wetland Areas and Environmentally Sensitive
Lands,Wafer/Wastewater Treatment.
' Southwest Florida Water Management 0ot�ct-VVeUs. Cypress. Boyheado, Wetland Areeo, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
' Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks. �
' US Envinzn[nenta| Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Rumways.
| understand that the following restrictions apply to the use offill:
' - Use of fill io not allowed in Flood Zone"V" u | expressly permitted.
fill- If the � material is to be used in Flood -Zone "A", it is understood that o drainage plan addressing o
"compensating volume" will be submitted at time of permitting which is prepared by o professional engineer
licensed by the State ofFlorida.
- If the fill material is to be used in Flood Zone "A", in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in �any area, | certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely off»ot adjacent pnopadies, the,owner may be cited for"violating
the conditions ofthe building permit issued under the attached permit application, for lots \eom than one (1)
acre which are elevated by fill, on engineered drainage plan is required.
if I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to cbmmenc(ng construction. | understand that n separate permit may be required for electrical work,
p|umhing. mgnn, yveUo, poo|a, air conditioning, gam' or other installations not specifically included in the application. A
permit issued aheU be construed to be a license to proceed with the vvork�and not as authority toviolate, cancel, eUer, or
set.aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless,the work authorized by such permit is commencedwithin.six months of permit issuance, or if work authorized by
the permit is suspended 6rablaridoned for a period of six(6) months after the time the work is commenced. An extension �
may be naguaetod, in vvriting, from the Building Official fora period not to exceed ninety (88) days and will demonstrate '
justifiable cause for the extension. If work ceases for ninety (90),consecutive days, the job is considered abandoned..
WARNING TO' . ER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY'RESULT IN.,YOUR `
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. /P YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER ORAN TTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
''` '
FLORIDA
.
OWNER O°AGENT CONTRACTOR
Subscribed and sworn to(or affirm d)before me this Subscribed and swqrr�fb(or affirmed)before me this
.
Who is/are persondW known to me or-��;
I as identification. '
--as identification.
Notary Public e, Notary Public
E_~-
Commission No. IF98537 - Commission Fe98537
. ` ` ^
ElissaM.Holleran Blioma M.BoDc/uuName of Notary tvoed,,printed or stamped Name of Notary typed,printed or stamped
tv
'
^
LOT S
PAD�101..E 6
TYPE'A ♦♦`♦ 0��2 u ♦
' ♦ , a1
Q . :1DD'` �01.80 .897` ♦. 3a�', 'LOT .?Q ,
f
d. ♦ 9 \pA�jfOf.Q. t�`"`�
,, ♦9 3D rAv:1O1:i i �'.< ` t03 „ 1d; E 8 p i �O�ti, •'y'• _ ;+
` >> 3� � _ �,03. ��� '.�':: � yea. .�,9 •;` � -
00
`\ � fOD.fi 2 FF,:1 0 to ♦,. X�. � r 6Q ,, g :S �' � �µ'S ;V: ti
03 PLOT S` \o . ♦ PAQ=101
r,
TYPE ♦ ' o, 0• f �
LV , f5 @'` c„Cj 3 — `7J.
004
♦ �,\ \.. ♦ o p 1QD.s FF= i. ; ♦aQ , ', TYP `~' '�'' g.
l♦ �, .� f Q2 1, 40. , }(?Q'gtf , ,. g `'•''
IC
LOT 6
ti y , ♦pa• 4D 10.1,4 ♦ AG?,ft10.1 �p��� yya p .1. 5j
h °a: �`�'. - 5 TYpE A \ 0•" `?" ! .. kPE B;. t! t lY: (y /�' _J
p
POND
/ r �{: ,�05\��' ♦. `� to1. PF= ♦ p, A, g31 ;. 08, FI
/'• 0— t ��• �,.. ,t\ ♦ D iQ2. ' 2; "99' 9 � ` b 0 t , f , ` } J $p
' t t3 y
;; Lor; ' ' '>�: • -i l�, OYRD W_ I
.lOf;d OZ9 i � 1 ,�40g°� � T � '�. r tt" Ff'.a
5 TYa �141 a, 9 ss� f 00.10 M, '.1" ! , R�HW_ .
;�:\__ _ a` ," fio. +LO.T" 13 1 j i DCw` 9
/ \_• ,,N N, 1Ny-." , t. \ . ♦ / A ♦ s.s '�� PADs1oQ,o" a I I 93 40
\.\ `.• `' �'�", \V\ _`. :.�.-` ;J•. ( - - J^T ♦♦�1 , Ot�; ,`, 'ad 1. , , ,, J I V
FFfQ1. I
9Q ♦ 1 s i 69 60�•.�.
�� \�. .��`. ,4, LOT.� 9 2 r i �q t 1 � I
TAG \.\ T D PAD 1+Z - , p Lot" �'.� I I Tag.
`� \'\ �'`. \� $k, '' A; ' tit g
� �,,/'+ F O� `8 ♦. 7Q �p0' ; Q" 1 $, ?' ;.. i r;•, 0 1 k;.
c� \ 061 .`'\ , ti 1 J PAD 9 _ ,9 _,.Y "�, PA&=fD0.2•
:•
X.
YA
? JQ` ,♦.. \\ �;9>�\. .<<. � \a \ ♦ p as �Q a 2
A:�'�` q'i : �`{ FF�1Q
'"�s` ;�� '\. � ,\�`1 ,RE`• `•a�`, � i .\.♦ ,,,".! '� ',, �:h4�' .�,'1 ? i �=1 j} � .0?, L�T ��
\\ ♦ \\ ♦ 6•`� ♦ 3; <. PAD ` 1°� _
\\ \. fly 'i 11 A �E.A �' / I -- .. . `` $
�g . 1
6.
' 01-' 11 '��, d:.' .p. --=••—... -.egg:., +��,",
7 , ,
SKETCH ONLY SEC. 04 TWP. 26 S, RNG. 21 "E.__PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: I
LOT 14, BLOCK 5 WEST BOUNDARY OF SUBJECT PLAT BEING N 02*35*32" E
SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
N MAY BE DISCLOSED BY A FULL AND ACCURATE
TITLE SEARCH, ALSO SUBJECT TO SETBACKS,
PRELIMINARY DRAWING:
THIS PLAN IS FOR PERMITTING PURPOSES EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY M UNDERGROUND FOOTER, STEM WALL, AND
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
SHOWN.
LEGEND:-IUAA. = PROPOSED DRAINAGE FLOW JDO NOT SCALE THIS PRINT. DIMENSIONS AND
(00,00) = PROPOSED GRADE < NOTES TAKE PREFERENCE.
0
E-00.00 = EXISTING GRADE in DESCRIPTION NOT CONTAINING PLAT BOOK AND
T PAGE INDICATES THAT PLAT IS IN
NOTES: PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = B CHANGE AND/OR REVISION.
PROPOSED PAD ELEVATION = 100.1'
FRONT SETBACK = 20' CERTAIN DATA SHOWN HEREON BASED ON
SIDE SETBACK = 7.5' ENGINEERING PLANS PROVIDED BY CLIENT.
REAR SETBACK = 15' TRACT E
DRAINAGE AREA STRUCTURE TIES SHOWN HEREON DENOTES
MEASUREMENT FROM FORM BOARDS/FOUNDATION
ZS TO PROPERTY LINE.
10' UTILITY EASEMENT
10' DRAINAGE EASEMENT
6
01
0)
ry
A) (98.0o')
LOT 15
BLOCK 5 0"
Zo
AD
43
ON LOT AREA CALCULATIONS
LOT 13 LOT = 8169.02 SQ. FT.
BLOCK 5 LIVING AREA =--2443 Q. FT.
ENTRY FT.
GARAGE FT.
COVERED LANAI =NA--SQ. FT.
PATIO = 32—SQ. FT.
(99,03') CONC. DRIVE =_1 —SQ. FT.
A/C & CONC PAD = L� SQ. FT.
PRIVATE SIDEWALK =__2_q_SQ. FT.
IMPERVIOUS
4019--SQ. FT.
SOD = A_!_29__SQ. FT.
00
rn OFF LOT AREA CALCULATIONS
nRIGHT OF WAY = 641.49.__SQ. FT.10 PCP DRIVE APRON = _LZk__SQ. FT.
o RADIUS PUBLIC SIDEWALK = !_4_q_SQ. FT.
POINT 0 SOD = Ul.__SQ. FT.
SADDLE PALM TOTALS
ro AREA = 8810_51SQ. FT-
WAY DRIVEWAY = 920 --SQ. FT.
(R/W VARIES) (TRACT G) SIDEWALK =--17-5SQ. FT.
SOD = !L329 SQ. FT.
PROPOSE LO :
DESCRIPTION:
06 LOWEST FORD ELEVATIONS:
aLOT 14, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES
LIVING AREA: 100.80'
6. 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE
x GARAGE AREA:
z u PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO
0�6 1 CURVE I RADIUS I ARC I CHORD I BEARING I DELTA NORTH AMERICAN VERTICALl
cl 68 300.00 1 32-43' DATUM OF 1988. MEAN SEA
uj
C169 i 55.00 38.57' 1 37.78' LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992
Project Number: Square Feet; 8169.02 f LENNAR HOMES
m LEGEND:
- (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q.7— CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
ITS
-0 PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS,,SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U U/P= UTILITY POLE, W/F= WOOD FENCE
z Drawn By.
9 JOHN R.BEACH&ASSOCIATES,INC. SMS
0 SURVEYORS AND MAPPERS
a t 911 WEST ST. PETERSBURG DRIVE Checked By.
U9 ONE OLDSMAR, FLORIDA 34677 JRB
j> WAY Scale:—1276 FAX (813) 855-8370(813) 854 V=30'
!a � "I?
r NOT VALID WITHOUT THE SIGNATURE AND PLAN 8/7/18 ACS
.2 THE ORIGINAL RAISED SEAL OF A FLORIDA 15rGNATTlW,, DATE
LICENSED SURVEYOR AND MAPPER
Revisions: FLORIDA REG. Q ND SURVEYOR No. 2984) LB#4493
JEFF M. HA
_E80FESSMAL SURVEYOR & MAPPER No.7123
:11
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0514
Project Name: 2485A sf ADS Carrier Builder Name: Lennar Homes
Street: 35989 Saddle Palm Way Permit office: City of Ze hyrhiUs
City,State,Zip: FL, Permit Number:r�1
Owner. Lennar Homes Jurisdiction: �T f�
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ft2
b.Frame-Wood,Adjacent R=11.0 312.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ft2
6. Conditioned floor area above grade(ft2) 2443 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 . c. R= ft2
11.Duct
s R ft2
7. Windows(207.3 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390
a. U-Factor: Dbl, U=0.54 135.25 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 32.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.193 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 2443.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.085 Total Proposed Modified Loads: 69.36 PASS
Total Baseline Loads: 69.70
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this , p
Code. calculation indicates compliance
�ave /w/ C/' with the Florida Energy Code. . i�-_
Wl YC
PREPARED BY: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, g as designed, is in co liance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: AUG 16 20 BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0514
Project Name: 2485A sf ADS Carrier Builder Name: Lennar Homes
Street: 35989 Saddle Palm Way Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ftz
b.Frame-Wood,Adjacent R=11.0 312.00 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ftz
6. Conditioned floor area above grade(ftz) 2443 b.N/A R= ftZ
Conditioned floor area below grade(ftz) 0 c.N/A R= ftZ
11.Ducts R ftz
7. Windows(207.3 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390
a. U-Factor: Dbl, U=0.54 135.25 ftz
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 40.00 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 32.00 ftz
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.193 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grad6 Edge Insulation R=0.0 2443.00 ftz b. Conservation features EF:0.950
b.N/A R= ftz None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.085
Total Proposed Modified Loads: 69.36 PASS
Total Baseline Loads: 69.70
I hereby certify that the plans and specifications covered by Review of the plans and �CtS.Tq"
this calculation are in compliance with the Florida Energy specifications covered by this p
Code. calculation indicates compliance
with the Florida Energy Code.
Dave AGal�icGt
PREPARED BY: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. Y �''Orj ,•
OWNER/AGENT: BUILDING OFF?
FF CIAL
DATE: DATE: - i
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
. f
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0514
Project Name: 2485A sf ADS Carrier Builder Name: Lennar Homes
Street: 35989 Saddle Palm Way Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1720.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1408.00 ft2
b.Frame-Wood,Adjacent R=11.0 312.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2443.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2443.00 ft2
6. Conditioned floor area above grade(ft2) 2443 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(207.3 sgft.) Description Area a.Sup:Attic,Ret:Attic,AH:Main 6 390
a. U-Factor: Dbl,U=0.54 135.25 ft2
SHGC: SHGC=0.33
b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl, U=0.56 32.00 ft2
SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.193 ft.
Area Weighted Average SHGC: 0.323 14.Hot water systems
8. Floor Types (2443.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 2443.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 69.36 PASS
Glass/Floor Area: 0.085 Total Baseline Loads: 69.70
I hereby certify that the plans and specifications covered by Review of the plans and 'fib-s.
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
Dave ,�Coll'rch with the Florida EnergyCode.
PREPARED BY: Before construction is completed '
DATE: this building will be inspected for
compliance with Section 553.908 h '�•
P
I herebycertify that this building,as designed, is in compliance Florida Statutes.
fY 9, 9 P
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFF IA
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 2485A sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2443 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 315 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 2443 19544
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 2443 19544 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 144 ft 0 2443 ft2 i e__ 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2646 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2443 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 2443 ft2 0.11 Wood
8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall Type
1 N=>NW Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft2 0 0.5 0
2 E=>NE Exterior Concrete Block-Int Insul Main 4.0999 58 8 8 469.3 ft2 0 0.5 0
3 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 42 8 336.0 ft2 0 0.5 0
4 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 8 8 64.0 ft2 0 0.5 0
5 W=>SW Exterior Concrete Block-Int Insul Main 4.0999 47 4 8 378.7 ft2 0 0.5 0
6 N=>NW Garage Frame-Wood Main 11 29 8 232.0 ft2 0.23 0.01 0
_7 W=>SW Garage Frame-Wood Main 11 10 8 80.0 ft2 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NW Insulated Main None .2 3 6 8 20 ft2
2 N=>NW Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => chan ed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NW 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 1 ft 0 in 3 ft 6 in None None
2 E=>NE 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None
3 S=>SE 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None
4 S=>SE 3 Metal Law-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 0 ft 10 in None None
5 S=>SE 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 0 ft 6 in None None
6 W=>SW 5 Metal Low-E Double Yes 0.54 0.33 N 48.0 ft2 1 ft 0 in 0 ft 10 in None None
7 S=>SE 3 Metal Law-E Double Yes 0.54 0.33 N 9.3 ft2 1 ft 0 in 0 ft 10 in None None
8 N=>NW 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 1 ft 0 in 5 ft 0 in None None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 636 ft2 636 ft2 60 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000254 1628.7 89.41 168.15 .1892 5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1
8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 390 ft2 Attic 97 ft2 Proposed Qn Main —cfm 73.3 cfm 0.03 0.50 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans: rl Coolin Jan Feb
Mar prr
Nov Dec
j May rl Jun
�j Oct
Venting Jan Feb M HJan Feb X�Maar r �j Apr May Jun f Xi Jul Aug jXj
Sep Oct Nov Dec
Oct Nov Dec
Jun [ Jul Aug Sep
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ft2 Oft , 0.3 Main
Name: Signature:
Rating Compant: Date:
8/14/2018 9:56 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Singgle-family b) Return ducts R 6.0
c)AHU location Attic/Attic
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13. Cooling system: Capacity 34.8
a)Split system SEER 15.0
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 2443 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.551
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.323 14. Heating system: Capacity 34.6
c)Area 7c. 207.3 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f) Other 8.50
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised(R-value) 9b. 15.Water heating system
c)Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 11.0
2.Masonry(Insulation R-value) 1062.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d)Multizone cooling credit
d) Radiant barrier installed 11 d. No e)Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded) in this home before final inspection. Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: 08/14/18
Address of New Hfe: 35989 Saddle Palm Way City/FL Zip: , FL Zephyrhills,FL 33541
8/14/2018 9:57:13 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Building Anal Job: 2485A sf ADS Carrier
g YSIS Date: 811 412 01 8
Entire House By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Design Co nditions
Location: Indoor: Heating Cooling
Tampa Intl AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 38 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.5 53.9
Dry bulb(OF) 32 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb (°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 - 7.5 Fireplaces 0
Component Btuh/ft' Btuh % of load
Walls 5.1 8956 27.6 Ducts
Glazing 29.2 6417 19.8 Wail
Doors 22.7 457 1.4 Infiltration
Ceilings 1.2 2963 9.1
Floors 2.7 6616 20.4
Infiltration 1.7 3498 10.8
Ducts 3517 10.8 Floors
Piping 0 0
Humidification 0 0 Glazing
Ventilation 0 0 Other Ceilings
Adjustments 0
Total 32424 100.0
a
Component Btuh/ft2 Btuh % of load
Walls 2.8 4957 17.9 Wall Internal Gains
Glazing 49.6 10905 39.5
Doors 18.6 373 1.4 Ducts
Ceilings 1.7 4257 15.4
Floors 0 0 0
Infiltration 0.4 757 2.7 Infiltration
Ducts 3519 12.7
Ventilation 0 0
Internal gains 2850 10.3 Ceilings
Blower 0 0 Glazing
Adjustments 0 Other
Total 1 1276181 100.0
Latent Cooling Load= 3267 Btuh
Overall U-value= 0.097 Btuh/ft2-°F
Data entries checked.
t -F-=i0htsoft- 2018-Aug-14 09:55:14
ACCA ^�^h Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...equipment\2485 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces:SW
Project Summary, Job: 2485A sf ADS Carrier
J Summary Date: 8/14/2018
Entire House By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Notes: FBC 2017
---Desicin Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 32 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/ib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 28907 Btuh Structure 24099 Btuh
Ducts 3517 Btuh Ducts 3519 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
Humidification 0 Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 32424 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 27618 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2537 Btuh
Ducts 730 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 2443 2443 Equipment latent load 3267 Btuh
Volume(ft3) 22893 22893
Air changes/hour 0." 0.11 Equipment Total Load (Sen+Lat) 30885 Btuh
Equiv.AVF (cfm) - 84 42 Req. total capacity at 0.85 SHR 2.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model 25HBC536AO0300 Cond 25HBC536AO0300
AHRI ref 9155179 Coil FX4DNF037L
AHRI ref 9155179
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh
Heating output 34600 Btuh @ 470F Latent cooling 5220 Btuh
Temperature rise 26 OF Total cooling 34800 Btuh
Actual air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 32 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Pl&- =ightsott- 2018-Aug-14 09:55:14
��- ^��•� w--ry�mpw Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCA ...equipment\2485 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW
Manual S Compliance Report Job: 2485A sf ADS Carrier
Date: 8/1 412 01 8
Entire House By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 27618 Btuh Entering coil DB: 75.5°F
Outdoor design WB: 77.2°F Latent gain: 3267 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 30885 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Sensible capacity: 29580 Btuh 107% of load
Latent capacity: 5220 Btuh 160% of load
Total capacity: 34800 Btuh 113% of load SHR: 85%
-Heating Equipment
Design Conditions
Outdoor design DB: 32.1°F Heat loss: 32424 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Output capacity: 27079 Btuh 84% of load Capacity balance: 32 °F
Supplemental heat required: 5345 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
Ai -Fo wrightsoft® 2018-Aug-14 09:55:14
, .rR.���.w,�.,� Right-Suite®Universal 2018 18.0.16 RSU05714
�� Page 1
...equipment\2485 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW