Loading...
HomeMy WebLinkAbout18-20429 CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020 20429 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20429 Issued: 11/05/2018 Address: 35997 SADDLE PALM WAY Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 383,685.90 Total Fees: 15,169.19 Subdivision: SILVERADO Amount Paid: 15,169.19 Date Paid: 11/05/2018 Parcel Number: 04-26-21-0080-00500-0130 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,466 SQ FT APPLICATION FEES BUILDING FEE 2,074.20 ELECTRICAL FEE 441.00 PLUMBING FEE 294.00 MECHANICAL FEE 205.80 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspection Inspectiong, keguired FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. IM h � & - &I fw 1� M4fttVCTO1Q,6'.1NGNATLlRE PERMIT OFFIjFA PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER •/ I� - l � 'L9'�--p z City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Q Site: 95 -( � ��1(� r Permit Type: Approved w/no comments:❑ Approved w/the below comments: kp Denied w/the below comments: ❑ JAW— This comment sheets,all be kept-with the permit and/or phins. Kalvin Swit'fy, Plans Examiner Date o ractor and/or omeowner (Required when comments are present) i 111{i1111111111111111111111111111111111111141�1{{I{ll4{lIII 2018184338 iRept:2002464 Rec: 10.00 !Lis: 0.00 IT: 0.00 10/31/2018 K. S. , Ltpty Clerk ^ /PAULA 9.01NEIL,Ph.D.PASCo CLERK & COMPTROLLER i 10OR SK 19811 RG 385 Permit No. Parcel ID No 04-26-21-0080-00500-0130 NOTICE OF COMMENCEMENT state of Florida County of Pasco' THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following.information is provided in this Notice of Commencement: I., Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75.BLOCK 05 LOT 13 Street Address: 35997 Saddle Palm Way Zephryhills FL . 33541 2. General Description of improvement"Single Family Residence 1 Pool!Screen Enclosure/Fence 3. 'Owner Information: Lennar Homes,'LLC. Name 4600 W Cypress St Ste 200 Tampa FL. 33607" Address City State Interest in Property: Name of Fee Simple Titleholder: 'N/A (If other than owner) Address City State " 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City- State Contractors Telephone No.: 813.574.5700 5. Surety: NIA Name Address City: State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida,Statutes: Lennar Homes- LLC Name 4600 W.Cypress.St,Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates NIA of to receive a copy of the Lienot's Notice as provided in Section 713.13(1)(b),Florida-Statutes.. Telephone Number of Person or Entity Designated by Owner: $. Expiration date of Notice-of Commencement is one.year from the date of recording.unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE.EXPIRATION OF THE NOTICE OF COMMENCEMENT. ARE'CONSIDERED IMPROPER PAYMENTS.UNDER CHAPTER 7.13, PART 1, SECTION713.13, FLORIDA STATUTES, AND CAN.' RESULT IN YOUR PAYING, TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.. A NOTICE OF COMMENCEMENT MUST BE. RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION.,-.IF YOU'INTEND TO OBTAIN FINANCING,CONSULT., WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA PINEL � COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President " Signatory's Title/Office The foregoing instrument was acknowledged before-me this 14 day of August by Steve Robert Smith as Vice President (type of autho' ,trustee,attorney in fact)for Lennar Homes LLC (name of p whom instrument was executed). Personally Known®-OR Produced Identification El No ure Type of Identification Produced' Name(Print) Elissa Holleran Verification pursuant to Section 92.625,Florida Statutes. Under penalties of perjury,1 declare that I have read the foregoing and.that the facts stated in it are true to.the best of my knowledge and belief. "11AFt;"O"'RAN Signature of Natura erson"Signing Above =, "Cemm!'eelott FF 90503t i .; F.x'IrerZe 0;2020 wpdata1bcs1bcs form:; ,p `' ¢!�I uTmyrFainlMunnteib03p570to 04-26-21-0080-00500-0130 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, November 3, 2018 Parcel ID 04-26-21-0080-00500-0130 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $28,886 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 35997 SADDLE PALM WAY ZEPHYRHILLS, FL 33541 Just Value $28,886 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,886 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 5 Taxable Value $28,886 LOT 13 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) - - --.. 16 ..-. .. --- .._. -._ ...----- - -_...- — --_ - :---- ------ .-- _ .- --.. - . _ --- - - - - _ Line ;Use escri tionZoning !Units Type ;Price _ ;Condition Value 1 0100 SFR i MPUD 6,000.00 ! SF $4.40 1.00 $26,400 2 0100 SFR MPUD i 6,216.00 { SF i $0.40 I 1.00 $2,486 Additional Land Information Acres 0.28 Tax Area` 30SI FEMA Residential Code SLVRCPI Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line Description ;Year ;Units ,Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page ;Type ;DOR Code;ConditionjAmount 10/2018 9811 / 1078 Warranty Deed i 05 Vacant 'Multi-Parcel Sale 03/2017 '9356 / 1223 Mineral Rights or Royalty Transfer) 05 Vacant !Multi-Parcel Sale 09/2011 ;8606 / 3376 Warranty Deed 05 Vacant ;Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126040080005000130 11/5/2018 Lennar Homes-35997 Saddle Palm Way-3,406 Sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,406 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 383,685.90 FEE SHEET $ 1,960.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 2,079.20 ELECTRICAL: $ 441.00 PLUMBING: $ 294.00 MECHANICAL: $ 205.80 SUB-TOTAL $ 3,020.00 Public Fee 1% TOTAL $ 3,020.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,573.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,174.19 Singe Family Dwellink: Plan Review Comments: 1. F.F.E. shall be a minimum of 8"above.the road elevation and an engineered site plan. . 2. Lots shall be graded to,comply with R401.3 of the F.B.C. ". . 3.. :Compa6tion:test required if 24 or more of fill dirt is brought in at any one place: 4:. :Tie irisurvey required before pouring concrete.. 5.. Driveways require a R.O.W. use permit: All 4 sides'of.driveway.thru the sidewalk shall have, expansion material: 6. All setbacks.shall be met.. . 7. :All property markers shall be.uncovered and marked at time'of first inspection: 8- All A.D.A. requirements shall be met.: . 9. No electric;plumbing,mechanical;,or training shall be covered without an inspection and approval first. . 10. All Garages shall.comply with-section R302,6.of the:F.B.C.(Fire Separation). 11. Appliances:shall not be installed in a location where subject to.mechanical-damage unless. protected by approved barriers. M303.4'ofthe F.B:C 12. Water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for.A/C.units shall be raised at least 3" above finished grade.. M1308.1 14.-Return'air in all.bedrooms.F.B.C. .M.1620.4,, 15. Smoke detectors are.to beinstalled:in accordance With.R313.1 ofthe:F.B..C. 16. A11 glazing requirements axe.to be in accordance with R308.4 of the F.B:C. 17. All means-of egress are to:be in:accordance withR311:of the F.B.C. 18. `.`Green gypsum board shall riot be used:as.a backer.in:showers or tubs.R702.4.2 F.B.C. = yp. .q . . _ . q. 19._'Combination-t . e AFCI breakers are requited.at all,locations re uirmg.an AFCI.type breaker: -20. Carbon monoxide alarms:will.be required in new.construction that uses fossil-burning heating or appliances or an attached garage.:. They shall be.installed in accordance with the F.B.C. 21. All plumbing, mechanical, and.electrical shall.be separate from unit to:unit: This includes all underground plurribin and electric. 22. All 2016 N.E.C-. Codes:will.be enforced. 23. Tamper= Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C . 24. In accordance with the Lan_ d Development.Code; lots.shall be sodded before final at least 10 . .. feet around.the structure. 25. Blower door test and blown in insulation card shall,be provided before C:O.. 26. A copy -of the enerAyy eacls.shall be with permit at.all tines. 27. Copy of fndl insulation report shall be:provided with:perinit before:flnaL . F.F.E.-Finished Floor Elevation F.B.0 Florida Building Code 6t'Edition R.O.w.-Right of Way A.D.A.-Americans with Disabilities Act' . :. N.E.C.-National Electric Code(2011) PASCO COUNTY, FLORIDA Permit No. �Zrj Date Permitted t t- 5-4 6 Builder Name/Owner Name �e~,a r Control#' County Parcel No. () SubDiv: �STlller'Q�v Address/Location s�tdd le Classification/Type of Use �c�IP ltrnl,ly 3; o4 -��— TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 31 (A Exempt ❑ Yes ❑ No How Determined Impact Fee Amount $.3, 3 .f� Zone No. TAZ: SCHOOL IMPACT FEE �, I q1j` 2g Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt H Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ `7 gJ S6 Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By �L Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY J72 PASCO COUNTY DEVELOPMENT SERVICES PASC 8731 Q'itiip'nstirive L0R.1D- I COUNTY F -�)VA - New Pqtt.R*i6hey 171-34654 727-847-2411 N t U-'* T A PERMIT Ri5ce1'pt.#: 1830388: 'FEE DESCRIPTION AddOUNTt'dibE UNITS:, INVOICE# FEEAMOUNT PAID. RECEIPT 9 DATE Impact Fee Residential lZol"d 24503100-329010 1.00 1427709 $6030 :$60.30 183 0 - 2/1 W1 9 i ,Waste'Single Family TOTALS: Uaao 16030 Receipt# Paid By 'Check# CC Auth-9 .Cashier ID Workstation Receint'Date Ami.Paid 1830336 Check 1155466 546 6 BC.CCP59W 02/12/24.019 '$50.30 Total Payments:! $60.30 Parlor Address Phone Lennar-Homes, LLC doffiments-' 35001 Saddle Palm Way While you will be-paving your-blll with Pasco'Courity D6vel&prnenfSe'rv16--s,the full 6riiounf of the credit card, or e-check-fe6s,NOT-shown above,is coll6cted-by first Billing paymerit services. M' Reports/reports/IPASCbPROD/PAbCO/ReceiotPOS V6.rpt 2/12/2019 y Pop I Of-I 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 __ 2891 111'°I 1111 111 1 - - Owner's Name Lennar Homes,LLC Owner;Phone Number I r813"574.5700 Owner's Address. 4600 W.Cypress St.Ste,200,Tampa,FL 33607• Owner Phone Number Fee Simple Titleholder Name NIA Owner Phone Number ,.Fee Simple Titleholder Address N/A JOB ADDRESS._ 35997 Saddle Palm Way LOT# 0130 , _ SUBDIVISION rado Ranch Subdivision Ph 6,8,9A PARCEL ID# 04-26-21-00 Sllve 80-00500-0130 - (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED F17-11 NEW CONSTR ADD/ALT 0 SIGN 0 0 .DEMOLI8H _ INSTALL e REPAIR PROPOSED USE SFR Q COMM 0 OTHER -4' TYPE OF CONSTRUCTION �� -. 'BLOCK 0 FRAME STEEL - DESCRIPTION OF WORK -__ Single Family Residence/Pool/Screen Enclosure/Fence 1 - u/R SF 3406 2576=: 1 Story BUILDING SIZE: - -SQ FOOTAGE, HEIGHT Y BUILDING $r (D�� VALUATION OF TOTAL CONSTRUCTION ` I �I�/-A,ELECTR1CAL. $ ® °PROGRESS ENERGY Q W.R.E.C. �'t,•_ r AMP SERVICE PLUMBING $ _ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION •- =GAS ROOFING•,.Q SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA RYES �10 Lennar Homes,LLC BUILDER - • ,• ! COMPANY � SIGNATURE-- REGISTERED Y/ N FEE CURREN Address 4600 W.Cypress.St:'Ste.2 ,Tampa,FL 33607 License# rEGC1518166 ELECTRICIAN j COMPANY Edmonson Electric, Inc. SIGNATURE I REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road, T pa, FL 336 License# EC13005408 PLUMBER FCOMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address ,P.O. Box 5308;Bayon , FL 34674-5 8 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O..Box 5308', Bayone , FL 34 4-5308 License# 1 CAd058062. OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 421I'Shoal Line Blvd, Spring Hill, FL 34607 = License# CCC057991 � RESIDENTIAL Attach(2)Plot Plans;(2)sets"of,Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.Ail commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER-_PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may-be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned eoaumeo responsibilityfor compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS N C f the owner has hired contractors Aci undertake worK they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law,,both the owner and contractor may be cited for a misdemeanor violation under state-law. If the owner or intended, Coritractor are uncertain as to what licensing requirements may apply for the intended work,'they.are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner*has�, hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of.this applickon for which they will be responsible. If you, as the owner sign.as the ' contractor, that may be on indication that he is not properly licensed and is not entitled to permitting privileges in Pasco ` County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Feeaand Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing bui|dinga, or expansion of existing bui\dingo, as specified in Pasco County Ordinance number88'O7 and 80'07, as emended. The undersigned also undorstonds, that such feeo, as may be due, will be identified at the time of permitting.' It is further understood that Transportation impact Fees and Resource Recovery Fees must be paid prior to receiving o "maddhoatanf occupancy" �[final power release. |f the pn�entdoes not involve aoe�Uiosdaof occupancy or � Yw na| poerre|a themus t Furthermore, If Pasco County Water/Sewer Impact fees due,theyniu-st-be paid prior to permiti in accordancewith applicable Pasco County ordinances.. CONSTRUCTION LIEN LAW'(Chapter7'13, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that |, the applicant, have.been provided with a copy- of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Deportment of Agriculture and Consumer Affairs. If the applicant is someone other than the"ovvnar". | certify that | have obtained a copy of the above described document and promise in good faith to deliver itto the^mwner"priorto commencement. CONTRACTOR'S/OWNER'S |l the inforl-riation-irl'this applicationis accurate andthat all work will be done-in with all applicablekaws regulating construction,,zoningd land deve nt 8p U ` "=e"x "== to obtain� n 'a p"."` to °° w"'" and installation" as indicated." ' certify that, "o work. or " s=°'""�' commenced . . performed onne�ucUnn County, codes, regulations, and land developnlent regulations in the ]u qq certify that I understand-that the regulatiofts,of.,.other.g6vernment agencies may apply to the intended,work, ar1d-thk,it i's at actions I musi-take.to be in h agencies include but are not limited to. - ' ' Department' - viProtection-Cypress Q� o`Wetland Areas and Environmentally Sensitive— - Lands, Treatment. ' Southwest Florida Water Management District-VVeka, Cypress Boyheado. Wetland 'Anaeo. Altering Watercourses, - Army Corps of - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells. ��� Treatment, � ' - Septic Tanks, ' US Environmental PnoteotionAge abatement. - Federal Aviation Auth n��yo� _~ - \ understand that the following restrictions apply to the use offill: ' Use of fill iy not allowed in Flood Zone W u ��d . .~. - If the fill material is to be used in Flood Zone ��, it is understood thet,a dnainaQe plan addresbng o "compenaotng volume" will be submitted at time of permitting.which is prepared by a pnfeuniona| engineer licensed by the State ofFlorida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted,-building using stem wall construction, | certify that fill will be used only to'fiU the area within the stem wall. If fill material is to be used in any area, I certify that use of such' fill will,, adversely properties. If use of fill is found to adversely affect adjacent properties, the owner may be:cited,jor violating the conditions_ _ of the building permit_ issued_ under -' _attached permit- '.lic . ts,loss. ` than . . acre which are elevated drainage plan is If I am,the AGENT FOR THE OWNER, I promise in good faith to inform the owner 'of the permitting conditions set forth in _this affidavit _prior to commencing construction. . _understand that - separate permit may be -`-re- for �l _l work. plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the.application. 'A *dcel, alter, or permit_- -issued shall- be construed _ -- - '__-- to proceed with the work and not as authority_ to violate,_ _ -_ set aside any provisions or the technical cooea. norana/ cmuanx:cna9ennup/evenuu/eou/mx/8vxicia/ xd1ou=xeaux requiring correction of errors in plans, construction violations of any codes. Every permitissued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work,'authorized by the ended or abandoned for a period of six 6) months after the time the work is commenced. An extension m be requested,' in writing, from the Building Official �for a period not to exceed ninety days andwiU demonstrate . justifiable cause for the extension. If work ceases for ninety(90)consecutive days',the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD ` OF COMMENCEMENT MAY RESULT IN YOUR SKETCH ONLY SEC. 04 1 TWP. 26 S, RNG. 21-E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 13, BLOCK SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02*35'32" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT N MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS TITLE SEARCH, ALSO SUBJECT TO SETBACKS, LOT =--1-2-2-1609 SQ. FT. y EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA = jfL7_6SQ. FT. = MUNDERGROUND FOOTER, STEM WALL, AND ENTRY FT. GARAGE = LZ4_SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. COVERED LANAI =_N/_6_SQ. FT. PATIO N/6—SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE FT. aNOTES TAKE PREFERENCE. A/C & CONC PAD = LZ_SQ. FT. C3 PRIVATE SIDEWALK 30 0. FT. fn DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS = 34 __. t PAGE INDICATES THAT PLAT IS IN 4187--SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO SOD = 8029 SQ. FT. CHANGE AND/OR REVISION. CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY =__.j OFF LOT AREA CALC _SQ. FTULATIONS ENGINEERING PLANS PROVIDED BY CLIENT. ;L7jjCL . DRIVE APRON = !Q_SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK = 215 —SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD = !L3_SQ. FT. ~ TRACT E TO PROPERTY LINE. DRAINAGE AREA TOTALS 0 AREA = 12553.89 0. FT. DRIVEWAY = A1_9SQ. FT. 66- SIDEWALK =_215—SO, FT. 119s, SOD =-AQ-7-2—SQ. FT. 7 PRELIMINARY DRAWING: _A THIS PLAN IS FOR PERMITTING PURPOSES 0 1 ONLY, NOT FOR CONSTRUCTION. VERIFY _003 ALL DIMENSIONS BEFORE ANY CONSTRUCTION. fro LEGEND: -A.Alt- = PROPOSED DRAINAGE FLOW LOT 14 (00.00) = PROPOSED GRADE BLOCK 5 G E-00.00 EXISTING GRADE TRACT H DRAINAGE AREA L"Q- NOTES: SILVERADO RANCH PHASES 2, 3 & 4 LOT GRADING TYPE = B (PLAT BOOK 73, PAGE 59) PROPOSED PAD ELEVATION = 100.6 FRONT SETBACK = 20' SIDE SETBACK = 7.5' REAR SETBACK = 15' r 1 16 li- I 'olo d''A ON 0 0 0 fi a, ICA U) 01 rn Cp SADDLE PALM 41 WAY (R/W VARIES) (TRACT G) 91 r_1 s —PRM S.8 .... .. . 4*55'01'E (Typ 55.00, S 89*07'31" W 119.66 PCP 0 RADITS) LN- POINT LLOCOT 1K2 PLAT B 5 BOUNDARY rn 10' UTILITY EASEMENT ca 10' DRAINAGE EASEMENT PROPOSED: p DESCRIPTION: LOWEST FLOOR ELEVATIONS: W LOT 13, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES LIVING AREA: 100.70' 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE GARAGE AREA: z PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO or 0 NORTH AMERICAN VERTICAL 1 CURVE I RADIUS I ARC I CHORD BEARING DELTA DATUM OF 1988. MEAN SEA I C170 1 55.00' 1 45.54' LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 Project Number: Square,Feet: 12216.09 f LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q7- CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/s= tO CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM-T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD,-FN&[)= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT CL !E REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No- 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U U/P= UTILITY POLE, W/F= WOOD FENCE z 9 Drawn By.JOHN R.BEACH&ASSOCIATES,INC. SMS Checked By. 0 SURVEYORS AND MAPPERS a t 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 A u j WAY (813) 854-1276 FAX (813) 855-8370 Scale:1"=30' —NOT VALID WITHOUT THE SIGNATURE AND TDIft e: PLOT PLAN 8/6/18 ACS .2 THE ORIGINAL RAISED SEAL OF A FLORIDA NATUR DATE LICENSED SURVEYOR AND MAPPER JOHN R. BEA Revisions: FLORIDA\REGND SURVEYOR No. 2984 LB#4493 :3 JEFF M. HARVY E St IRVEYOR Ar MAPPER No.7123 aQEESSYW� P4LOT 3 OT4 j 76 t 99 4 "Plol N. tfl0.fi Ff, �aj4' �. a say' ; o ��.. r , LOT PAD 100 g�' ` ' '� C`l '. \,-¢' •� a3 PAd;ial?3 a',, �. ..., A \` ao ' Lod:'t \ . 2 g' ; s PAO"10a;4. Ra ,48. o, ss 1ofl a: \ 'l.• ; Ac: 02.1 v ,= o .i �QQ , tp 80 �� , c f• '�; ,: LOT: g. i , �� , T 114, tiQk P101.4 .\. r C ; 1 PIPE©o.l 54 9 i v r•.. ND po .\ - � ` `"1 4Qj ; 9.Q � � 1 t '� �� r R`�.• '• � t"1 .,ik5a ,�, \ � (y t/ , f 0 h'py i n\. `; \ \ o AADttai:4 9'7. ,"; \ a TYPEA, >` . -,.t raa:a '. �,"�Q {y}y+ '`( /♦y}}��,�//I� 4p t ` \-\ ,, � `;,.\ •\ �,. ;1 . : r 1 ,.. . fly y ti �, , �- ,, p , N �� �ti: �' 9 �� � ��o• ., \.�_ ,�;� ,,,,,\ ; , ,� lflos �''.tal,sa ��� ' ' 9�• ,; 69 � -'�` �'p - � : ?�'- �� 6061:�[ 4 �".. \ gy� � \ ,:` `;. � 1:1 i. �,k rAU A' � vrpla; IA �':,1x.; ` , O FI 41Q 1 �•Jy. , �' f .. �`�"r' t,►M �4tiQ , `\\ "'g1 \ 1 t �, �'i t. g70 rAu-- `1 n J PAf, g faa.2' P` , ,, t .`�, -A Q`�:. C5), 3a Fet 1 40 / 4s f` 6 _v 6 6 Lop o, .: P SOT `_.'1, �g y _ t p FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS Carrier Builder Name: Lennar Homes 0513 Street: 35997 Saddle Palm Way Permit Office: Ci%t�rQf�,ephyrhills City,State,Zip: FL, Permit Number: 2 Y Owner: Lennar Homes Jurisdiction: 61,1 e 'UMPO Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:.Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor:' N/A ft2, a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: z Area Weighted Average Overhang'•Depth;- 1.744 ft. Area Weighted Average SHGC: = 0.326, 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (2576.0 sqft.) Ansulation Area EF:0.950 a.Slab-On-Grade Edge Insulation' R=0'0 2576.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 72.98 PASS Glass/Floor Area: 0.083 - Total Baseline Loads: 73.00 I hereby certify that the plans.and'specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code:, j calculation indicates compliancejv 'Dave /� G� with the Florida Energy Code. PREPARED'BY: Before construction is completed - DATE: this building will be inspected for l compliance with Section 553.908 I herebycertifythat1his building,as designed, is in comp'once Florida Statutes. x, with the Florida Energy Code. aQ4 OWNER/AGENT: BUILDING O FICIAL: DATE: DATE: - Compliance requires certification by the air.h dler unit manufacturer that the air handler enclosure qualifies as t' certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 .i FORM R405-2017. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS Carrier Builder Name: Lennar Homes 0513 Street: 35997 Saddle Palm Wa Permit Office: Y City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ftZ b.Frame-Wood,Adjacent R=11.0 380.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ftZ 6. Conditioned floor area above grade(ftZ) 2576 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl, U=0.54 159.00 ftZ SHGC: SHGC=0.33 b. U-Factor: Dbl, U=0.58 40.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl, U=0.56 16.00 ftZ SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor:' N/A ftZ a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.744 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ftZ EF:0.950 g b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.98 PASS Total Baseline Loads: 73.00 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. _ calculation indicates compliance with the Florida Energy Code. Dave Aup cGt PREPARED BY: Before construction is completed DATE: this building will be inspected for N compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. :: with the Florida Energy Code. `- OWNER/AGENT: BUILDING OFFICI L: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2), - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS Carrier Builder Name: Lennar Homes 0513 Street: 35997 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ftz b.Frame-Wood,Adjacent R=11.0 380.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft 6. Conditioned floor area above grade(ftz) 2576 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ftz SHGC: SHGC=0.33 b. U-Factor: Dbl, U=0.58 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl, U=0.56 16.00 ftz SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.744 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ftz b. Conservation features EF:0.950 b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.98 PASS Total Baseline Loads: 73.00 I hereby certify that the plans and specifications covered by Review of the plans and _:011E!Sx7 this calculation-are in compliance with the Florida Energy specifications covered by this p Code. calculation indicates compliance `'�+r; ' _ ;,•� :�s+. 'Dave with the Florida Energy Code. PREPARED BY: pG{� Before construction is completed 1 DATE: this building will be inspected for J. compliance with Section 553.908 I hereby certify that this building designed,as Florida Statutes. _; with the Florida Energy Code. g , is in compliance OWNER/AGENT: BUILDING OFFICIAL DATE: DATE. - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 'INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 2606E sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2576 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Hillsborough Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 2576 20608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2576 20608 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 174 ft 0 2576 ft2 ___ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2790 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2576 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 2576 ft2 0.11 Wood 8/14/2018 9:02 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 'INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 18 8 8 149.3 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 67 4 8 538.7 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.600000 0 4 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 7 8 56.0 ft2 0 0.600000 0 5 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0 6 N=>NE Garage Frame-Wood Main 11 31 8 248.0 ft2 0.23 0.01 0 7 E=>SE Garage Frame-Wood Main 11 2 8 16.0 ft2 0.23 0.01 0 8 W=>NW Garage Frame-Wood Main 11 14 6 8 116.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 6 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 4 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 92.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 5 S=>SW 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 3 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5 6 W=>NW 5 Metal Low-E Double Yes 0.54 0.33 N 12.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 7 W=>NW 5 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 674 ft2 674 ft2 57 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 2060.8 113.14 212.77 .227 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 515.2 ft Main 128.8 ft Proposed Qn Main —cfm 103.0 cfm 0.04 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma Jun ri Jul rl Au rj Se Oct [ ]Nov ]Dec Heatin Jan Feb f X�Mar f Apr f May Jun Jul Au Sep Oct ]Nov X]Dec Ventin Jan Feb X Mar [X A r [ Ma Jun Jul Aug Se [X Oct [X]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 -11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Coaling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD), AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD' ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts,location&insulation level a)Supply ducts R 6.0 2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 34.8 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2576 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.549 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.326 14. Heating system: Capacity 34.6 c)Area 7c. 215.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c) Electric resistance . COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised (R-value) 9b. 15.Water heating system c)Concrete, raised(R-value) 9c. a)Electric resistance EF 0.95 b) Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10B1. 11.0 2.Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or ex eeded) in this home before final inspection. Otherwise,a new EPL display card will be completed based on i talled code compliant features. Builder Signature: Date: 08/14/18 Address of New Home: 35997 Saddle Palm WE City/FL Zip:- , FL Zephyrhills,FL 33541 8/14/2018 9:03:12 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Buildin Anal sis Job: 2606B sf ADS Carrier g Y Date: 811412018 - Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave.Hudson Project • • For: Lennar Homes -Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.2 9097 26.9 Dias Glazing 30.2 6456 19.1 wall Doors 23.5 473 1.4 nfiltration Ceilings 1.3 3231 9.6 Floors 2.9 7385 21.9 Infiltration 1.7 3433 10.2 Ducts 3687 10.9 Floors Piping 0 0 Glazing Humidification 0 0 Ventilation 0 0 Other Ceilings Adjustments 0 Total 33763 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 4860 16.6 wall Internal Gains Glazing 54.1 11574 39.5 Doors 18.4 370 1.3 Ceilings 1.7 4468 15.2 Ducts Floors 0 0 0 r Infiltration 0.4 714 2.4 Infiltration Ducts 3602 12.3 Ventilation 0 0 Internal gains 3750 12.8 Blower 0 0 Glazing Ceilings Adjustments 0 other Total 1 1293381 100.0 Latent Cooling Load= 3245 Btuh Overall U-value= 0.095 Btuh/ft2-°F Data entries checked. wrightsofit- 2018-Aug-14 09:00:37 •�^h �wq ,P� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..equipment\2606 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:SW ' Job: 2606B sf ADS Carrier Project Summary Date: 8/14/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project I • • For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 30076 Btuh Structure 25736 Btuh Ducts 3687 Btuh Ducts 3602 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33763 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29338 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2481 Btuh Ducts 764 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2576 2576 Equipment latent load 3245 Btuh Volume(ft3) 21723 21723 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 32583 Btuh Equiv.AVF(cfm) 80 40 Req. total capacity at 0.85 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC536AO0300 Cond 25HBC536AO0300 AHRI ref 9155179 Coil FX4DNF037L AHRI ref 9155179 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 26 °F Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 32°F Backup: n/a-n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F�F- wrightsoft- 2018-Aug-14 09:00:38 ^-^•� w-��^pA Right-Suite®Universal 2018 18.0.16 RSU06714 page 1 ACCk ..equipment\2606 sf ADS template 3ton Canier.rup Calc=MJ8 Front Door faces:SW Manual S Compliance Report Job: 26068 sf ADS Carrier Date: 8/14/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 29338 Btuh Entering coil DB: 75.5°F Outdoor design WB: 77.3°F Latent gain: 3245 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 32583 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29580 Btuh 101% of load Latent capacity: 5220 Btuh 161% of load Total capacity: 34800 Btuh 107% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 33763 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26344 Btuh 78% of load Capacity balance: 32 of Supplemental heat required: 7419 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. t -Fk- wrightsoft® 2018-Aug-14 09:00:38 �, •dR•r��.=w� •, Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 A'M ...equipment12606 sf ADS template 3ton Car ier.rup Calc=MJ8 Front Door faces:SW FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606E sf ADS Carrier Builder Name: Lennar Homes 0513 Street: 35997 Saddle Palm Way Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1520.00 ftZ b.Frame-Wood,Adjacent R=11.0 380.00 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10:Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft 6. Conditioned floor area above grade(ftZ) 2576 b.N/A R= ft2 Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl, U=0.54 159.00 ftZ SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 16.00 ftZ SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.744 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ftZ b. Conservation features EF:0.950 b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.98 PASS Total Baseline Loads: 73.00 I hereby certify that the plans and specifications covered by Review of the plans and ~fi�rlE 5 . this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. Dave Aui cG� PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is' compliance Florida Statutes. with the Florida Energy Code. o ;y OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by a air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordan a with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606E sf ADS Carrier Builder Name: Lennar Homes 0513 Street: 35997 Saddle Palm Way Permit office: City of Zephyrhjlls City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.744 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.98 PASS Total Baseline Loads: 73.00 I herebycertify that the plans and specifications covered b Review of the plans and S fY P P y P , �_ �4T'• (Q. this calculation are in compliance with the Florida Energy specifications covered by this - •p" ,�' V Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave AWich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. �,• with the Flonda.Energy Code. OWNER/AGENT: BUILDING OFFICI : DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS Carrier Builder Name: Lennar Homes 0513 Street: 35997 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Black-Int Insul,Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2576.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl, U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.744 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.98 PASS Total Baseline Loads: 73.00 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ABC/- with the Florida Energy Code. Dave PREPARED BY: tf Before construction is completed {2 q, DATE: this building will be inspected for , compliance with Section 553.908 St atutes. tatutes. I hereby certify that this building,as designed, is in compliance Florida with the Florida Energy Code. d Oljy�tf,T¢ OWNER/AGENT: BUILDING OFFI G IAI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 'INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 2606B sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2576 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Hillsborough Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 2576 20608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2576 20608 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 174 ft 0 2576 ft2 ---- 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2790 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2576 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 2576 ft2 0.11 Wood 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 } FORM R405-2017 'INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt To Wall T-y.pe 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 18 8 8 149.3 ft2 0 0,600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 67 4 8 538.7 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.600000 0 4 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 7 8 56.0 ft2 0 0.600000 0 5 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0 6 N=>NE Garage Frame-Wood Main 11 31 8 248.0 ft2 0.23 0.01 0 7 E=>SE Garage Frame-Wood Main 11 2 8 16.0 ft2 0.23 0.01 0 8 W=>NW Garage Frame-Wood Main 11 14 6 8 116.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 6 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 4 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 92.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 5 S=>SW 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 3 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5 6 W=>NW 5 Metal Low-E Double Yes 0.54 0.33 N 12.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 7 W=>NW 5 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 674 ft2 674 ft2 57 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 2060.8 113.14 212.77 .227 - 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 i FORM R405-2017 'INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 515.2 ft Main 128.8 ft Proposed Qn Main ---cfm 103.0 cfm 0.04 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma rj Jun ri Jul rj Au Se Oct Nov ]Dec Heatin Jan Feb f X Mar �JA Pr j j May Jun Jul Au �Xj Sep f i Oct H Nov X]Dec Ventin Jan Feb X Mar Apr May Jun Jul Aug Se [X Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 r Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft2 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 8/14/2018 9:02 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 34.8 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2576 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.549 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.326 14. Heating system: Capacity 34.6 c)Area 7c. 215.0 _ a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised (R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f)Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10B2. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a)Under attic 11 a. 30.0 b) Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat Yes "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be completed based nstalled code compliant features. Builder Signature: Date: 08/14/18 Address of New Home: //35997 Saddle Palm WE City/FL Zip: , FL Zephyrhills,FL 33541 8/14/2018 9:03:12 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Buildin Anal sis Job: 2606E sf ADS Carrier g Y Date: 8114/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration:. Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftZ Btuh % of load Walls 5.2 9097 26.9 Ducts Glazing 30.2 6456 19.1 wall Doors 23.5 473 1.4 nfiltration Ceilings 1.3 3231 9.6 Floors 2.9 7385 21.9 Infiltration 1.7 3433 10.2 Ducts 3687 10.9 Floors Piping 0 0 Glazing Humidification 0 0 Ventilation 0 0 Other Ceilings Adjustments 0 Total 33763 100.0 • • Component Btuh/ftZ Btuh % of load Walls 2.8 4860 16.6 Wall Internal Gains Glazing 54.1 11574 39.5 Doors 18.4 370 1.3 Ceilings 1:7 4468 15.2 Ducts Floors 0 0 0 Infiltration 0.4 714 2.4 Infiltration Ducts 3602 12.3 Ventilation 0 0 Internal gains 3750 12.8 Blower 0 0 Glazing Ceilings Adjustments 0 Other Total 29338 100.0 Latent Cooling Load= 3245 Btuh Overall U-value= 0.095 Btuh/ftZ-°F Data entries checked. -w i_ghtsI - 2018-Aug-14 09:00:37 •�^� M �^^�-°• Right-Sufte®Universal 2018 18.0.16 RSU05714 Page 1 ..equipment%2606 sf ADS template 3ton Carrier.rup Cale=MJ8 Front Door faces:SW Project Summary Job: 2606E sf ADS Carrier J ry Date: 8/14/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 30076 Btuh Structure 25736 Btuh Ducts 3687 Btuh Ducts 3602 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33763 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29338 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2481 Btuh Ducts 764 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 2576 2576 Equipment latent load 3245 Btuh Volume(ft') 21723 21723 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 32583 Btuh Equiv.AVF (cfm) 80 40 Req. total capacity at 0.85 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC536AO0300 Cond 25HBC536AO0300 AHRI ref 9155179 Coil FX4DNF037L AHRI ref 9155179 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 34600 Btuh @ 47'F Latent cooling 5220 Btuh Temperature rise 26 OF Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 32 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^ � wihso= - rigtft- 2018-Aug-14 09:00:38 .'� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCA ...equipment\2606 sf ADS template 3ton Carrier.rup Cale=MJ8 Front Door faces:SW C t Manual S Compliance Report Job: 2606B sf ADS Carrier p Date: 8/14/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 29338 Btuh Entering coil DB: 75.5°F Outdoor design WB: 77.3°F Latent gain: 3245 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 32583 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29580 Btuh 101% of load Latent capacity: 5220 Btuh 161% of load Total capacity: 34800 Btuh 107% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 33763 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26344 Btuh 78% of load Capacity balance: 32 OF Supplemental heat required: 7419 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. - wrightsoft® 2018-Aug-14 09:00:38 1, •dR•�m� w�..�,M Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCK ...equipment\2606 sf ADS template 3ton Carrier.rup Cale=MJ8 Front Door faces:SW