HomeMy WebLinkAbout18-20430 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20430
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:20430 Issued: 11/05/2018 Address: 36002 SADDLE PALM WAY
Permit Type:-, NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 461,076.45 Total Fees: 15,754.19 Subdivision: SILVERADO
Amount Paid: 15,754.19 Date Paid: 11/05/2018 Parcel Number: 04-26-21-0080-00500-0100
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 4,093 SQ FT
APPLICATION FEES
BUILDING FEE 2,472.00 ELECTRICAL FEE 528.75 PLUMBING FEE 352.50
MECHANICAL FEE 246.75 FIRE IMPACT FEE 273.00 POLICE IMPACT FEE 254.00
PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28
TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 PARK FEES SF 769.56
Inspections Required
FOOTER 2ND R U H PLUMB MI INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
41cbNTRAdTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting 813 363 2891
tttttttt ttttt
Owner's Name Lennar Homes,LLC Owner Phone Number r8l .574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 36002 Saddle Palm Way LOT# IVIS
SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCEL ID#1 04-26-21-0080-00500-0100
,f (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED 11./ II NEW CONSTR H
ADD/ALT SIGN DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR Q COMM = OTHER
TYPE OF CONSTRUCTION BLOCK FRAME = STEEL =
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 4093 SQ FOOTAGE 3255 HEIGHT 2 Story
✓ BUILDING $ VALUATION OF TOTAL CONSTRUCTION
r-71
I�/ 'ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY W.R.E.C.
���. rrr
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS W1 ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do
t t t t t F t . ..fir
BUILDER COMPANY 'Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 License# EC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N I FEE CURREN Y/N
Address 0034 Skipper Road,Tampa, FL 33613 License# E 113005408
PLUMBER COMPANY Bayonet Plumbing, He &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5308 License# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc77
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5308 License# CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCC057991
ttttt � ttttttttttt � ttttttttt � � ltttttttttt � tttllttttt � tttttttttt � ttt � tt
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of'Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater-Plans w/Silt Fence installed, .
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
■ ■
Directions:■
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVERT COUNTER PERMITTING (copy of contract required)
Rev"' Ies Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
of over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance vsith any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor.may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone"A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.1111�7.03)
OWNER OR AG_ENT(J/ � _ CONTRACTOR~
aa-
Subscribed and sworn to(or affirm- )before me this Subscribed and sworn to(or affirmed)before me this
GJ-Jul-1 b by Ashlee Callahan 23.J"i-1e by Ashlee Callahan
Who is/are personally known to me or Who is/are personally known to me or has`have^F^a..� �-
as 1 tification. as identification.
Notary Publ(:::::
Notary Public
COMMssion No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
I�F�i�JilE1���aa(�Q BaS�d�hNToayF�alp�a�lOR.1llRlGll
Lennar Homes-36002 Saddle Palm Way-4,093 sqft
bl .1
o umn ts
SQ. FEET PRICE
MAIN OR LIVING: 4,093 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 461,076.45
FEE SHEET $ 2,350.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 2,477.00
ELECTRICAL: $ 528.75
PLUMBING: $ 352.50
MECHANICAL: $ 246.75
SUB-TOTAL $ 3,605.00
Public Fee 1%
TOTAL $ 3,605.00
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,158.35
PARK IMPACT FEES $ 769.56
SIF'S: .$ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,759.19
e11 ms'
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: Le"Ctiv'
Date Received: ( 7=:�
Site: d 2SAMI
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall e t with the permit and/or pl
Kalvin Switzer P s Examiner Date retractor an or Homeowner
(Required when comments are present)
P-ASCO-COUNTY
DEVELOPMENT SERVICES
8731 Citizens Drive 2/12/2019
PPASCDate:,� ,'COUNTY' FL 0 R I D�V-' New.Port Richey, FL 34654
727-847-2411
MOT JA_% Irn— ERNT
ReciBi'pt#! 1880327
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE'AMOUNT PAID RECEIPT# DATE
Impact-Pee Residelifial Solid 245031 0032901 0 1.60 1427696 $60-3.0 $.50.50 18.30327 2/12/19
Waste Single Family
TOTALS. $60.30 $60.30
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
163027 Check 1466463 BCC-CP59W 62/12/2010 $00.30
Total Payments' $60.30
Pavor Address Phone
Lennar Homes, LLC
Comtriefifik
36002 Saddle Palm'Way
-While you will be paying your bill wlt,h-PascoCounty Development ServlcesTthe full amount-of the credit card or e-check-fees,-NOT-shown above;-is collected
First Billing payment services.
MyRepprtstreports//PASCOPROD/PASCO/Rec6.iptPO,S_.y6.rpt 211-2/2019 Page 1 of 1
PASCO COUNTY, FLORIDA
Permit No. Z6l,36 _
Date Permitted
Builder Name/Owner Name CLY Ytt&S `-'+cam Control#
County Parcel No. SubDiv:
Address/Location
6 2 SMdk �41M way
3
Classification/Type of Use CS 2 4
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: _
Exempt ❑�(es ❑ No How Determined
Impact Fee Amount $. 3,�D3L Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [] Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 70,54
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑ Yes [] No How Determined Total Amou
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY ,
RECEIPT NO. DATE BY
r - _
N0 �NNNNK�UNUNNNU0N \
-- ../�mommmmn�U00N0NNNN
2018184335
��' ^���� 10.00
. . ' 0.00 IT: 0 o0
� '
' S' ' 0#ty Clerk
omNEsL.nx,o p0000 o�snx
~ ` xw/����0 « COMPTROLLER
` �0 �N 1 of
PG 382
Permit No. Parcel mwo |'
..
NOTICE OF COMMENCEMENT
State of Florida county of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice ofCommencement:
1. Description mProperty: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 05 LOT 10
Street Address: FL 33541
/ /
o. General oeoohpuonov|mpnmamem Singled Pool E | Fence
u. Owner Information: bennarHomao L.L.C.
Name
Tampa FL�I3GD7
Address � city State
Interest mProperty:
Name mr Fee Simple Titleholder, N/\
(if other than owner)
Address city State
4. Contractor:
Name
Address city State
Contractor's Telephone mu.: 813.574.5700
e. Surety:
Name
Address city State
Amount ofBond: Telephone No.:
a. Lender: /»
Name
Address city State
uemmerxTelvp»vnewo.:
7. pomono within the State of Florida designated by the nwmo, upon whom nwU000 or other documents may be mnned as provided by
nectiun71o.13(l)$4(7).Florida Statutes:
Name
FL,336O7
Address City State
Telephone Number of Designated Person: 813.574.5700
u. m addition m himself,the owner designates NIA of
to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes.
Telephone Number vvPerson v,Entity Designated by Owner:
e. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
NOTICEWARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE opFLORIDA
COUNTY OFp\wsLuAe
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before mpthis 23 day of by
Steve Robert S ith m fact)for
(name was executed).
Personally Known X OR Produced Identification[I Not gqa1ure
Type of Identification Produced Na=Tn—t) fissa<olleran
Verification pursuantmSomionnu.5uo.RorivaStatuma. Undorpemo|tiemofpe4ury.|dedamthat|havereadoeforegoingandtho8mfaumotatedm
u are true m the best ofmyknmwodQe and belief.
ELISSAM.HOLLERAN ignature of Natural Person Signing Above
wpdata/bcs/bcs form:
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510
Street: 36002 Saddle Palm Way Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number: 20g30
Owner. Lennar Homes Jurisdiction: &U298- 016-a
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 376
a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50
b.Central Unit 24.0 SEER:15.50
c. U-Factor. Dbl,U=0.58 40.00 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.355 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090
Total Proposed Modified Loads: 98.94 PASS
Total Baseline Loads: 98.98
I hereby certify that the plans and specifications covered by Review of the plans and S
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance �;�,'s�
with the Florida Energy Code.
PREPARED BY: ve AUkichBefore construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code. �0
OWNER/AGENT: � BUILDING OFF EI
DATE: DATE: '
- Compliance requires certification by t air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
FOP,M R40,5-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510
Street: 36002 Saddle Palm Way Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft21 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 376
a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.58 40.00 ft2 b.Central Unit 24.0 SEER:15.50
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.355 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.94 PASS
Total Baseline Loads: 98.98
hereby certify that the plans and specifications covered by Review of the plans andk1E'.ST,9?,..
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
Dave �l,�fl'lcGc 9Y
PREPARED BY: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes. ,
with the Florida Energy Code. �'
o�Wf�
OWNER/AGENT: BUILDING OFFI L:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE' FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510
Street: 36002 Saddle Palm Way Permit office: City of ZephyrhiIls
City,State,Zip: FL, Permit Number:
Owner Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2
6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 376
a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275
SHGC: SHGC=0.30
b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.58 40.00 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.355 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950
b.Floor over Garage R=11.0 679.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.94 PASS.
Total Baseline Loads: 98.98
I hereby certify that the plans and specifications covered by Review of the plans and CT S"r
this calculation are in compliance with the Florida Energy specifications covered by this �'Q _ -_ 0'
Code. calculation indicates compliance'
with the Florida Energy Code.
PREPARED BY: Dave Aupich Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 *-
I herebycertify that this building,as designed, is in compliance Florida Statutes. .5
fY 9� 9 P
with the Florida Energy Code. Olj wrl:1��
OWNER/AGENT: BUILDING FICIAL:
DATE: DATE: l "
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.030 Qn for whole house.
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 3246A sf ADS Carrier Bedrooms: 5 Address Type: Street Address
Building Type: User Conditioned Area: 3255 - Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 90 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1880 16168
2 Block2 1375 11000
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1st Floor 1880 16168 Yes 2 1 1 Yes Yes Yes
2 2nd Floor 1375 11000 No 4 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 71 ft 0 1880 ft2 0.3 0 0.7
2 Floor over Garage 2nd Floor ____ __- 679 ft2 11 0.3 0 0.7
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2772 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2559 ft2 N N
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5
i
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1375 ft2 0.11 Wood
2 Under Attic(Vented) 1st Floor 30 Blown 1184 ft2 0.11 Wood
3 Knee Wall(Vented) 2nd Floor 30 Batt 84 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w
1 N=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 20 9 8 8 179.8 ft2 0 0.600000 0
2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 56 8 8 485.3 ft2 0 0.600000 0
3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 43 8 8 372.7 ft2 0 0.600000 0
4 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 7 8 8 60.7 ft2 0 0.600000 0
5 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 27 10 8 8 241.2 ft2 0 0.600000 0
6 N=>E Garage Frame-Wood 1 st Floor 11 28 8 8 8 248.4 ft2 0.23 0.01 0
7 W=>N Garage Frame-Wood 1 st Floor 11 25 8 8 8 222.4 ft2 0.23 0.01 0
8 N=>E Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft' 0.23 0.600000 0
9 S=>W Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft2 0.23 0.600000 0
10 E=>S Exterior Frame-Wood 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0
11 W=>N Exterior Frame-Wood 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>E 1 Metal Low-E Double Yes 0.56 0.3 N 32.0 ft2 3 ft 0 in 0 ft 6 in Drapes/blinds None
2 E=>S 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
3 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
4 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
5 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 9.3 ftz 1 ft 0 in 1 ft 3 in Drapes/blinds None
6 S=>W 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 1 ft 3 in Drapes/blinds None
7 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 32.0 ft2 1 ft 0 in 3 ft 5 in Drapes/blinds None
8 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
9 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 21.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
10 E=>S 10 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
11 W=>N 11 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 679 ft2 679 ft2 56 ft 8.6 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000318 2716.8 149.15 280.5 .2954 6
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubTpe Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 80 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None , None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat, Cool
1 Attic 6 376 ft2 1 st Floor 94 ft2 Proposed Qn 1st Floor —cfm 56.4 cfm 0.03 0.50 1 1
2 Attic 6 275 ft2 2nd Floor 68.75 ft Proposed Qn 2nd Floor —cfm 41.3 cfm 0.03 0.50 2 2
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr May Jun Jul ri Aug �Xj Se [ ]Oct Nov Dec
Heatin Jan Feb Xj Mar APrMay Jun Jul E ]Au SeP []Oct Nov f X�Dec
Ventin Jan Feb X Mar [X A r [ Ma Jun Jul ]Au Se [X]Oct H
Nov [ Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 - 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 1 st Floor
Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 2nd Floor
Name: Signature:
Rating Compant: Date:
7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
. • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts,location&insulation level
a)Supply ducts R 6.0
2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location varies
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 5 13. Cooling system: Capacity 48.0
a)Split system SEER 15.5
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 3255 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.555
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.315 14. Heating system: Capacity 48.0
c)Area 7c. 292.6 a)Split system heat pump HSPF 9.0
b)Single package heat pump HSPF
8. Skylights c)Electric resistance COP
a)U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised(R-value) 9b. 11.0 15.Water heating system
c)Concrete,raised(R-value) 9c. a)Electric resistance EF 0.95
b)Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 11.0
2.Masonry(Insulation R-value) 1062.
16. HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c)Knee walls/skylight walls 11 c. 30.0 d)Multizone cooling credit
d)Radiant barrier installed 11 d. No e)Multizone heating credit
f)Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL
display card will be completed based on i d code compliant features.
Builder Signature: Date: 07/25/18
Address of New Ho e- 36002 Saddle Palm Way City/FL Zip: . FL Zephyrhills,FL 33541
7/25/2018 1:10:50 PM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Building Anal Job: 3246A sf ADS Carrier
g YSIS Date: 7/25/2018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Sarasota Bradenton, FL, US Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD (°F) 38 17
Latitude: 27°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0
Dry bulb(°F) 33 92 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 79 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
• 1
Component Btuh/ft2 Btuh % of load
Walls 5.2 6768 28.6 uas
Glazing 28.9 4556 19.3 wall nfiltration
Doors 22.5 446 1.9
Ceilings 1.3 1508 6.4
Floors 3.1 5823 24.6
Infiltration 1.7 2558 10.8
Ducts 2010 8.5 Floors
Piping 0 0
Humidification 0 0 Glazing
Ventilation 0 0 other Ceilings
Adjustments 0
Total 23670 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.9 3795 19.0 Internal Gains
Glazing 58.4 9212 46.0 walls
Doors 19.0 375 1.9 Ducts
Ceilings 1.9 2216 11.1 Infiltration
Floors 0 0 0
Infiltration 0.4 614 3.1
Ducts 2101 10.5 Ceilings
Ventilation 0 0
Internal gains 1700 8.5 Other
Blower 0 0
Adjustments 0 Glazing
Total 20013 100.0
Latent Cooling Load= 1859 Btuh
Overall U-value= 0.112 Btuh/ft2-°F
Data entries checked.
` -Fk =1ghtsoft- 2018-Jul-2513:58:14
^�^•k Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
Buildin Anal SI$ Job: 3246A sf ADS Carrier
g Y Date: 7125/2018
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Design C• • •
Location: Indoor: Heating Cooling
Sarasota Bradenton, FL, US Indoor temperature ff) 70 75
Elevation: 26 ft Design TD (°F) 38 17
Latitude: 27°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0
Dry bulb(°F) 33 92 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 79 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ftz Btuh % of load
Walls 3.6 4072 30.3 ucts
Glazing 28.9 3827 28.5 wall
Doors 0 0 0
Ceilings 1.2 1650 12.3 nfiltration
Floors 1.9 9 0.1
Infiltration 1.7 2161 16.1
Ducts 1727 12.8 other
Piping 0 0 Ceilings
Humidification 0 0
Ventilation 0 0 Glazing
Adjustments 0
Total 13445 100.0
• • i
Component Btuh/ft2 Btuh % of load
Walls 2.8 3171 18.1
Glazing 50.7 6724 38.4 walls Internal Gains
Doors 0 0 0
Ceilings 1.8 2424 13.8
Floors 0.9 4 0.0 Ducts
Infiltration 0.4 518 3.0
Ducts 1814 10.4
Ventilation 0 0 Infiltration
Internal gains 2855 16.3 other
Blower 0 0
Adjustments 0 Glazing Ceilings
Total 17510 100.0
Latent Cooling Load= 3279 Btuh
Overall U-value= 0.097 Btuh/ftz-°F
Data entries checked.
=1Qhtsc ft- 2018-Jul-25 13:58:14
MCA ^�°° �°°w yam. Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
Summary Project •' Job: 3246A sf ADS Carrier
Date: 7/2512018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
i
For: Lennar Homes
Notes:
Design Information
Weather: Sarasota Bradenton, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 OF Outside db 92 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 17 OF
Daily range L
Relative humidity 50 %
Moisture difference 63 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 21659 Btuh Structure 17912 Btuh
Ducts 2010 Btuh Ducts 2101 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 23670 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 20013 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 1381 Btuh
Ducts 478 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1880 1880 Equipment latent load 1859 Btuh
Volume(ft') 16486 16486
Air changes/hour 0.23 0.12 Equipment Total Load (Sen+Lat) 21871 Btuh
Equiv.AVF(cfm) 62 32 Req. total capacity at 0.85 SHR 2.0 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER. j
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.034 cfm/Btuh Air flow factor 0.040 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.92
Capacity balance point= 33 OF
Backup:
Input= 7 kW, Output=24093 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.� -Fk wrightsoft- 2018-Jul-25 13:58:14
^�^•�a• a•^- - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
Summary ProjectSummary Job: 3246A sf ADS Carrier
Date: 7/25/2018
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Notes:
Design Information
Weather: Sarasota Bradenton, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 33 OF Outside db 92 OF
Inside db 70 OF Inside db 75 OF
Design TD 38 OF Design TD 17 OF
Daily range L
Relative humidity 50 %
Moisture difference 63 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 11718 Btuh Structure 15696 Btuh
Ducts 1727 Btuh Ducts 1814 Btuh
Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 13445 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 17510 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2867 Btuh
Ducts 412 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ft') 1375 1315 Equipment latent load 3279 Btuh
Volume(ft') 10998 10998
Air changes/hour 0.29 0.15 Equipment Total Load (Sen+Lat) 20789 Btuh
Equiv.AVF(cfm) 52 27 Req. total capacity at 0.85 SHR 1.7 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING
Model 25HBC524A00300 Cond 25HBC524A00300
AHRI ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.060 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point= 19 OF
Backup:
Input=4 kW, Output= 13485 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft® 2018-Jul-2513:58:14
Right-Suite®Universal 2018 18.0.16 RSUD5714
ACCk ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Page 2
• i
Loads for Multiple Orientations Job: 3246A sf ADS Carrier
Date: 7/26/2018
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
i
Project • •
For: Lennar Homes
Design C• • •
Location: Indoor: Heating Cooling
Sarasota Bradenton, FL, US Indoor temperature(°F) 70 75
Elevation: 26 ft Design TD (°F) 38 17
Latitude: 27°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0
Dry bulb(OF) 33 92 Infiltration:
Daily range(°F) - 14 ( L )
Wet bulb(°F) - 79
Wind speed (mph) 15.0 7.5
Front Door North' Northeast East Southeast South Southwest West Northwest
Sensible Load(Btuh) 17510 16929 15755 17721 19007 17964 14744 17178
Latent Load (Btuh) 3279 3279 3279 3279 3279 3279 3279 3279
Total Load (Btuh) _20789 20208 19034 21000 22286 21243 18022 20457
Heating AVF(cfm) 800 800 800 800 800 800 800 800
Cooling AVF (cfm) 800. 800 800 800 800 800 800 800
Building Orientation Cooling Load
25000
2000
r
m
v
0 1500
J
m
C i
O
U
m 1000
0
F-
5000
0
N NE E SE S SW W NW
Direction Front Door faces
Current Orientation: Front Door faces North
Highest Cooling Load: Front Door faces South
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-*- wrightsoft® 2018-Jul-2513:58:14
,L ��R•k• �•� ��mwm Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACCA ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
Loads for Multiple Orientations Job: 3246A sf ADS Carrier
Date: 712512018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
• I
8950 New York ave,Hudson
I
Project • •
For: Lennar Homes
Design C• • •
Location: Indoor: Heating Cooling
Sarasota Bradenton, FL, US Indoor temperature(OF) 70 75
Elevation: 26 ft Design TD (OF) 38 17
Latitude: 270N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0
Dry bulb(OF) 33 92 Infiltration:
Daily range(OF) - 14 ( L )
Wet bulb(OF) - 79
Wind speed (mph) 15.0 7.5
Front Door .-North Northeast East Southeast South Southwest West Northwest
Sensible Load(Btuh) r- 20013 18586 15306 17921 18864 18294 16020 18578
Latent Load (Btuh) .1859 1859 1859 1859 1859 1859 1859 1859
Total Load (Btuh) __21871 20445 17165 19780 20723 20153 17879 20437
Heating AVF (cfm) = 800 800 800 800 800 800 800 800
Cooling AVF (cfm) -800 800 800 800 800 800 800 800
Building Orientation Cooling Load
2500
• I
20000
L
Qt
0 1500
J
O1
_C
O
O
U
m 10000
0
H
5000
0
N NE E SE S SW W NW
Direction Front Door faces
Current Orientation: Front Door faces North
Highest Cooling Load: Front Door faces North
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
® -�- wrightsoft- 2018-Jul-2513:58:14
Aurt t•/B ne va 4tluny ampM Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
ACCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
Manual S Compliance Report Job: 3246A sf ADS Carrier
Date: 7/25/2018
lower floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling-
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 92.3°F Sensible gain: 20013 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 78.8°F Latent gain: 1859 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21871 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 102% of load
Latent capacity: 3600 Btuh 194% of load
Total capacity: 24000 Btuh 110% of load SHR: 85%
Heating • •
Design Conditions
Outdoor design DB: 32.5°F Heat loss: 23670 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 18859 Btuh 80% of load Capacity balance: 33 °F
Supplemental heat required: 4811 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 7.1 kW 102% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
-wrightsoft® 2018-Jul-25 13:58:15
CC a�•�a= mow- ------ Right-Suite®Universal 2018 18.0.16 RSU05714
Page 1
...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
Manual S Compliance Report Job: 3246A sf ADS Carrier
Date: 7/25/2018
upper floor By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson-
Project Information
I,
For: Lennar Homes
Coo-ling -Equ'ipment
Design Conditions
Outdoor design DB: 92.3°F Sensible gain: 17510 Btuh Entering coil DB: 75.5°F
Outdoor design WB: 78.8°F Latent gain: 3279 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 20789 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 117% of load
Latent capacity: 3600 Btuh 110% of load
Total capacity: 24000 Btuh 115% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 32.5°F Heat loss: 13445 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 18852 Btuh 140% of load Capacity balance: 19 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 4.0 kW 100% of load Temp. rise: 50 °F
Meets all requirements of ACCA Manual S.
1 wrightsoft® 2018-Jul-2513:58:15
•-I.......— Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
XCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N
1.02.0 t -
D-1•Q1 3 : PAD= 00.4 9:9
t Z
LOT
TYPE B '
1YPE q • �\` �- R''az� h' ��� '
' r r
X)o3,.99�.' ��Q PAD=�1�U 1: ca�'�g6 g8� ` •', // / �---
,. ho. " s 6 h TYPE '
=iQi.i.o ``, 'io .i : . �,� �� 9 .s .�; �, <r EX. POND E1
,.. LOT s'.. . + " `+.f . < TOB=98.0 y
=101.4 �'� � . °� , �`' 1 �9OOYRDFIW=97.
1
TYPE A. .�� ,;� t1 _ ,. �g0' 9. -} 125YRDHW=9&,
'b. ^" ''+.•, i'hx7�:l30 �'\• \``�,\ •' -\Q� `'t `' ry fit' . 1K'�F%iQV.7Q `+� �• •! DLW^93.40F1PAD,NC
F=10z, �;: 9s ihoL,t3T 13 NW�93.CJ°' 9 I � RAC
•toi.0 PAD=100.0LO .ti - O 1` ,YPE S '+"` 1 ` � �� EXIS
PAD'i01�4 O �. h + cp 6-
TYP��A �` 1'09.9� ��0 0 �`. 900 �� Q.,gO ,°�. __-fig,` G L(
3t* �10, \ h \ s' '1 Eg g ra ` I �g�a ENGINEERNCONTRACT(
• � o , �F; � �. � �19.
2. PAD Et.EV,
BUILDING.IN
,1 10o,Ls .LOT. - w
f'Afl= Qt2 `�' Oh. 9�.75 �`9•st �Y t t� 70 `` k 3. LOTS REG
+ :0 % 92 ' ` ` ~ PER FHA' I
�� •A.`, - t1� "gg.p5 was' `. 9�• ,, �i ` `,� ? 0 �•
PF= '?.90 Zit �-- l g�O SIMILAR Tf
0� \��5 h 60�t� �Oh. O { O r t`t )2 + , `. '. ��'� . THE ABSEI
t' -- ` , O `;5 PA --1 oQ:2 j / 4. FOR AL
N, 'I � 'oott . F 1O�170 , , l r ---dbc .• i` 9 +.�g�� �t Qf / ��y O 6?,�-_ BEYOND T
' �Jf� THE APPR
PAS.-i o t o 6 /q'r y/�g6 f r
TYf F A +,�/ ! r�. Il;`L ',' i g'1 p1" f i c - 1 5. SIDE SWA
'O , � t
' ` __ CONSTRUC
. �. Xto . . . 'h,+ .. `. r �' }'a FF=1�A1.40. `�, =z-
`. IN. .. ' `, g LOT ' 1. 0 1 1-____ _ _ �, SHALL GR
'� '," Ok. '+ Oy. O •', `, I0 , PAI0.7 BELOW
N46'-` \' �` k �. � i, L4 1Q$ t HYPE q`, g. �c�o . . --"'__ jE s. R p
+�'" pi
+`. '+, LOTS, ALL
`� ;, ! ' J a' �f' .°" 1 `` ` .� _ -_______ 9$-_--_- , `'I ,1 , 7. FOR TYPI
-� �ti. rod f+ r ,* �, _ ___ __ __ � __ g
'1`• . . 7'`,. + •-r`- ssNf /.1J + `Q1• 99.` _ (� "_ C� �- g� LOTS, ALL
l+ Spy •1 .++ + .� � ',`� /�? f °' ° '-3!`Vf '(� '', "y<--- -. �-
.� , \ - :h1 �9 i � F ff°'p�° +�"' r`' /gyp t 6 9 O i �0 r "�.�_ --- 8• FOR TYPI
_ �.! ti. u g t BUILDER\• `+``�ti �' �� `' O �t �f`.z,� 'f`h0� +� � "• � �^\ 10+0'4 y..��0�'1 g�`1[' O -6` ,`� g'S°' t � R
\.: t t , �f0 3 -� f o o,`b' r$g TO THE F
ENGINEER
IN
MINIMUM
' :\\`�0��` -�-�;' \ \• �' . . ` +r�(? -r� i ��' s '^� i' 1 1 h0 �` 1 t CX19.65
X99.1
.\ .':�:.. \. .. ; ';' , . i t gg,2 10. UTILITIES
; ; 32
THE BASE
.\. .. ��',,��>>" ,� :'�' " 'S .REC.T ' �S' L OC
:.
TED 1N FLOOD • ZONE A, 'AE & X ACCORD/NG TO FEW
:R:M. CdMMUNITY PANEL "NO;:. 12101 C .0288E & �2 9 09 C 0289E ELEVATIONS BASED Ot
DATED a9f2sf2014 (NAVD88), COtVVERS
=__ -
04-26-21-0080-00500-0100 1 Pasco County Property Appraiser Page 1 of 1
i
Data Current as Of: Weekly Archive - Saturday, November 3, 2018
Parcel ID 04-26-21-0080-00500-0100 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $26,525
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
36002 SADDLE PALM WAY
ZEPHYRHILLS, FL 33541
Just Value $26,525
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $26,525
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $26,525
BLOCK 5
LOT 10
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line ,Use �Description'Zoning Units ;Type .Price :Condition ;Value
1 1 0100 SFR MPUD 6,000.00 SF $4.00 1.00 $24,000
2 i 0100 i SFR ! MPUD 6,312.00 SF $0.40 1.00 $2,525
Additional Land Information
FEMA - - -
Acres 0.28 Tax Area 30SI Code -- Residential Code SLVRLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line Description Year ;Units Value
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year;Book/Page ;Type DOR Co_ de;Condition'Amount
10/2018 9811 / 1078 Warranty Deed ! 05 Vacant Multi-Parcel Sale
03/2017 j9356 / 1223 ;Mineral Rights or Royalty Tra_nsfe_ri 05 Vacant 'Multi-Parcel Sale_
09/2011 ;8606 / 3376 Warranty Deed 05 Vacant :Multi-Parcel Sale
http://search.pascopa.com/parcel.aspx?parcel=2126040080005000100 11/5/2018
Lennar Homes-36002 Saddle Palm Way 4,093 sq ft
Column IS
SQ. FEET PRICE
MAIN OR LIVING: 4,093 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 461,076.45
FEE SHEET $ 2,350.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 2,472.00
ELECTRICAL: $ 528.75
PLUMBING: $ 352.50
MECHANICAL: $ 246.75
SUB-TOTAL $ 3,600.00
TOTAL $ 3,600.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 4,153.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,754.19
Single Family Dwelling
Plan Review Coininents
l: F.F.E. shall be a.minim. of 8"above"the road.elevation,and an engineered site plan. "
2.. "Lots shall-be graded.to comply withR401.3 of theF.B:C.
"
3.= ;Compaction test required if24"or m6reof-fill dirt is brought in at any one place:
4: "Tie in.survey-required before pouring concrete..
5.- Driveways:require-a R:Q:W use permit. Alto sides of driveway thru the sidewalk slialthave = `
expansion material:
6. All setbacks.shall be met..
7.: ;All property markers shall be uncovered and marked.at time'of first inispection:
8 All A:D:A:requirements shall be met.
9. "No:electric;plumbing,'mechanicaL_or framing shall be covered without an:inspection.and
approval"first.
10.A11 Garages shall comply: C:with,section R302,6:of the.F.B. (Fire Separation).
11: Appliances:shall not.be installed in,a location ivliere subject to"mechanical"damage"unless
r9tedted b a roved barriers. M303-.4
p. . Y pp . of."the.F.B:C.
12. Water heaters shalt comply with section:P607.3"of the F.R.C. -
13. Foundation supports-for.A/C-units shall be raised at Jeast 3" above finished grade.. M13083 - -
14.Return ai.r in all-bed roozns..F.B.C. NI1620:4
15. Smoke detectors are.to be installed in accordance-with"R3111 of the:F.B.C.
l b:"All glazing requirements"are.to be in accordance with-R308-.4 of the F.B.C.
17. All means,of egress are to.be' in4c'cordance with R311::of the F;B.G. .
18. "Green gypsum board $Ball not be used as a backer.in:showers or tubs. R702.4:2T.B.C: "
19.Combination-type AFCI breakers are required:at all,locations requiring"an AFCI,type breaker:
20*-Carbon monoxide alarms will be required in-row ow construction"that-uses fossil_-burning heating
or appliances organ attached garage . They shall be installed in accordance
ply- g g Y with the F.B.C:
p g� . i p . ..
2 L'All lumbin" mechanical -and.electrical shall be se "arate""from unit.to unit: 'This:includes all -
underground plurribing and electric,
22. All 2616:N.E.C. Codes.will be enforced".
23:;Tamper= Resistant Receptacles in accordance with 406.11�of the 2016 N.E:C
24"-Ah accordance-.with"the Land..Development Code' .lots.shall be sodded"before final at least""10
feet around:the structure.
25. Blower door test and'blown in insulation card shall be provided before C.-O. .
26.A copy ofthe enemy cacls.shall be with permit"at all times.
27. Copy of final insulation report shall be:provided.witli:permit before.rinab
F.F.E.-Finished Floor-Elevation
FB.C-Florida Building Code 6th Edition
R.O.W-Right ofway
A:D.A:-Americans with Disabilities Act N.E.C.-National Electric Code(2011)