Loading...
HomeMy WebLinkAbout18-20430 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20430 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20430 Issued: 11/05/2018 Address: 36002 SADDLE PALM WAY Permit Type:-, NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 461,076.45 Total Fees: 15,754.19 Subdivision: SILVERADO Amount Paid: 15,754.19 Date Paid: 11/05/2018 Parcel Number: 04-26-21-0080-00500-0100 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 4,093 SQ FT APPLICATION FEES BUILDING FEE 2,472.00 ELECTRICAL FEE 528.75 PLUMBING FEE 352.50 MECHANICAL FEE 246.75 FIRE IMPACT FEE 273.00 POLICE IMPACT FEE 254.00 PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 PARK FEES SF 769.56 Inspections Required FOOTER 2ND R U H PLUMB MI INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 41cbNTRAdTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 2891 tttttttt ttttt Owner's Name Lennar Homes,LLC Owner Phone Number r8l .574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 36002 Saddle Palm Way LOT# IVIS SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCEL ID#1 04-26-21-0080-00500-0100 ,f (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED 11./ II NEW CONSTR H ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM = OTHER TYPE OF CONSTRUCTION BLOCK FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 4093 SQ FOOTAGE 3255 HEIGHT 2 Story ✓ BUILDING $ VALUATION OF TOTAL CONSTRUCTION r-71 I�/ 'ELECTRICAL $ AMP SERVICE ® PROGRESS ENERGY W.R.E.C. ���. rrr PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS W1 ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do t t t t t F t . ..fir BUILDER COMPANY 'Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 License# EC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N I FEE CURREN Y/N Address 0034 Skipper Road,Tampa, FL 33613 License# E 113005408 PLUMBER COMPANY Bayonet Plumbing, He &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc77 SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License# CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCC057991 ttttt � ttttttttttt � ttttttttt � � ltttttttttt � tttllttttt � tttttttttt � ttt � tt RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of'Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater-Plans w/Silt Fence installed, . Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ■ ■ Directions:■ Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVERT COUNTER PERMITTING (copy of contract required) Rev"' Ies Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) of over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance vsith any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor.may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone"A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.1111�7.03) OWNER OR AG_ENT(J/ � _ CONTRACTOR~ aa- Subscribed and sworn to(or affirm- )before me this Subscribed and sworn to(or affirmed)before me this GJ-Jul-1 b by Ashlee Callahan 23.J"i-1e by Ashlee Callahan Who is/are personally known to me or Who is/are personally known to me or has`have^F^a..� �- as 1 tification. as identification. Notary Publ(::::: Notary Public COMMssion No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped I�F�i�JilE1���aa(�Q BaS�d�hNToayF�alp�a�lOR.1llRlGll Lennar Homes-36002 Saddle Palm Way-4,093 sqft bl .1 o umn ts SQ. FEET PRICE MAIN OR LIVING: 4,093 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 461,076.45 FEE SHEET $ 2,350.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 2,477.00 ELECTRICAL: $ 528.75 PLUMBING: $ 352.50 MECHANICAL: $ 246.75 SUB-TOTAL $ 3,605.00 Public Fee 1% TOTAL $ 3,605.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,158.35 PARK IMPACT FEES $ 769.56 SIF'S: .$ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,759.19 e11 ms' City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Le"Ctiv' Date Received: ( 7=:� Site: d 2SAMI Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall e t with the permit and/or pl Kalvin Switzer P s Examiner Date retractor an or Homeowner (Required when comments are present) P-ASCO-COUNTY DEVELOPMENT SERVICES 8731 Citizens Drive 2/12/2019 PPASCDate:,� ,'COUNTY' FL 0 R I D�V-' New.Port Richey, FL 34654 727-847-2411 MOT JA_% Irn— ERNT ReciBi'pt#! 1880327 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE'AMOUNT PAID RECEIPT# DATE Impact-Pee Residelifial Solid 245031 0032901 0 1.60 1427696 $60-3.0 $.50.50 18.30327 2/12/19 Waste Single Family TOTALS. $60.30 $60.30 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 163027 Check 1466463 BCC-CP59W 62/12/2010 $00.30 Total Payments' $60.30 Pavor Address Phone Lennar Homes, LLC Comtriefifik 36002 Saddle Palm'Way -While you will be paying your bill wlt,h-PascoCounty Development ServlcesTthe full amount-of the credit card or e-check-fees,-NOT-shown above;-is collected First Billing payment services. MyRepprtstreports//PASCOPROD/PASCO/Rec6.iptPO,S_.y6.rpt 211-2/2019 Page 1 of 1 PASCO COUNTY, FLORIDA Permit No. Z6l,36 _ Date Permitted Builder Name/Owner Name CLY Ytt&S `-'+cam Control# County Parcel No. SubDiv: Address/Location 6 2 SMdk �41M way 3 Classification/Type of Use CS 2 4 TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: _ Exempt ❑�(es ❑ No How Determined Impact Fee Amount $. 3,�D3L Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [] Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 70,54 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes [] No How Determined Total Amou RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY , RECEIPT NO. DATE BY r - _ N0 �NNNNK�UNUNNNU0N \ -- ../�mommmmn�U00N0NNNN 2018184335 ��' ^���� 10.00 . . ' 0.00 IT: 0 o0 � ' ' S' ' 0#ty Clerk omNEsL.nx,o p0000 o�snx ~ ` xw/����0 « COMPTROLLER ` �0 �N 1 of PG 382 Permit No. Parcel mwo |' .. NOTICE OF COMMENCEMENT State of Florida county of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice ofCommencement: 1. Description mProperty: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 05 LOT 10 Street Address: FL 33541 / / o. General oeoohpuonov|mpnmamem Singled Pool E | Fence u. Owner Information: bennarHomao L.L.C. Name Tampa FL�I3GD7 Address � city State Interest mProperty: Name mr Fee Simple Titleholder, N/\ (if other than owner) Address city State 4. Contractor: Name Address city State Contractor's Telephone mu.: 813.574.5700 e. Surety: Name Address city State Amount ofBond: Telephone No.: a. Lender: /» Name Address city State uemmerxTelvp»vnewo.: 7. pomono within the State of Florida designated by the nwmo, upon whom nwU000 or other documents may be mnned as provided by nectiun71o.13(l)$4(7).Florida Statutes: Name FL,336O7 Address City State Telephone Number of Designated Person: 813.574.5700 u. m addition m himself,the owner designates NIA of to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes. Telephone Number vvPerson v,Entity Designated by Owner: e. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: NOTICEWARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE opFLORIDA COUNTY OFp\wsLuAe Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before mpthis 23 day of by Steve Robert S ith m fact)for (name was executed). Personally Known X OR Produced Identification[I Not gqa1ure Type of Identification Produced Na=Tn—t) fissa<olleran Verification pursuantmSomionnu.5uo.RorivaStatuma. Undorpemo|tiemofpe4ury.|dedamthat|havereadoeforegoingandtho8mfaumotatedm u are true m the best ofmyknmwodQe and belief. ELISSAM.HOLLERAN ignature of Natural Person Signing Above wpdata/bcs/bcs form: FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510 Street: 36002 Saddle Palm Way Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: 20g30 Owner. Lennar Homes Jurisdiction: &U298- 016-a Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2 6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 376 a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275 SHGC: SHGC=0.30 b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50 b.Central Unit 24.0 SEER:15.50 c. U-Factor. Dbl,U=0.58 40.00 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.355 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=11.0 679.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.94 PASS Total Baseline Loads: 98.98 I hereby certify that the plans and specifications covered by Review of the plans and S this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �;�,'s� with the Florida Energy Code. PREPARED BY: ve AUkichBefore construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. �0 OWNER/AGENT: � BUILDING OFF EI DATE: DATE: ' - Compliance requires certification by t air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 FOP,M R40,5-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510 Street: 36002 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2 6. Conditioned floor area above grade(ft21 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 376 a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275 SHGC: SHGC=0.30 b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.58 40.00 ft2 b.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.355 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=11.0 679.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.94 PASS Total Baseline Loads: 98.98 hereby certify that the plans and specifications covered by Review of the plans andk1E'.ST,9?,.. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. Dave �l,�fl'lcGc 9Y PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. , with the Florida Energy Code. �' o�Wf� OWNER/AGENT: BUILDING OFFI L: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE' FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 3246A sf ADS Carrier Builder Name: Lennar Homes 0510 Street: 36002 Saddle Palm Way Permit office: City of ZephyrhiIls City,State,Zip: FL, Permit Number: Owner Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(3190.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1380.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1339.70 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 470.89 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2643.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2559.00 ft2 6. Conditioned floor area above grade(ft2) 3255 b.Knee Wall(Vented) R=30.0 84.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(292.6 sqft.) Description Area a.Sup:Attic,Ret: 1st Floor,AH:1st Floor 6 376 a. U-Factor: Dbl,U=0.56 133.33 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 275 SHGC: SHGC=0.30 b. U-Factor: Dbl,U=0.54 119.25 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.33 a.Central Unit 24.0 SEER:15.50 b.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.58 40.00 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.355 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (2559.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1880.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=11.0 679.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 98.94 PASS. Total Baseline Loads: 98.98 I hereby certify that the plans and specifications covered by Review of the plans and CT S"r this calculation are in compliance with the Florida Energy specifications covered by this �'Q _ -_ 0' Code. calculation indicates compliance' with the Florida Energy Code. PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 *- I herebycertify that this building,as designed, is in compliance Florida Statutes. .5 fY 9� 9 P with the Florida Energy Code. Olj wrl:1�� OWNER/AGENT: BUILDING FICIAL: DATE: DATE: l " - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNETIICC 380, is not greater than 0.030 Qn for whole house. 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 5 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 3246A sf ADS Carrier Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 3255 - Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1880 16168 2 Block2 1375 11000 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1880 16168 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1375 11000 No 4 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 71 ft 0 1880 ft2 0.3 0 0.7 2 Floor over Garage 2nd Floor ____ __- 679 ft2 11 0.3 0 0.7 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2772 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2559 ft2 N N 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 5 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1375 ft2 0.11 Wood 2 Under Attic(Vented) 1st Floor 30 Blown 1184 ft2 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 30 Batt 84 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w 1 N=>E Exterior Concrete Block-Int Insul 1 st Floor 4.0999 20 9 8 8 179.8 ft2 0 0.600000 0 2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 56 8 8 485.3 ft2 0 0.600000 0 3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 43 8 8 372.7 ft2 0 0.600000 0 4 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 7 8 8 60.7 ft2 0 0.600000 0 5 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 27 10 8 8 241.2 ft2 0 0.600000 0 6 N=>E Garage Frame-Wood 1 st Floor 11 28 8 8 8 248.4 ft2 0.23 0.01 0 7 W=>N Garage Frame-Wood 1 st Floor 11 25 8 8 8 222.4 ft2 0.23 0.01 0 8 N=>E Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft' 0.23 0.600000 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 50 8 400.0 ft2 0.23 0.600000 0 10 E=>S Exterior Frame-Wood 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0 11 W=>N Exterior Frame-Wood 2nd Floor 11 36 3 8 290.0 ft2 0.23 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>E 1 Metal Low-E Double Yes 0.56 0.3 N 32.0 ft2 3 ft 0 in 0 ft 6 in Drapes/blinds None 2 E=>S 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None 3 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 32.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None 5 S=>W 3 Metal Low-E Double Yes 0.54 0.33 N 9.3 ftz 1 ft 0 in 1 ft 3 in Drapes/blinds None 6 S=>W 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 2 ft 0 in 1 ft 3 in Drapes/blinds None 7 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 32.0 ft2 1 ft 0 in 3 ft 5 in Drapes/blinds None 8 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 9 N=>E 8 Metal Low-E Double Yes 0.56 0.3 N 21.3 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 10 E=>S 10 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 11 W=>N 11 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds None 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 679 ft2 679 ft2 56 ft 8.6 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000318 2716.8 149.15 280.5 .2954 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None , None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat, Cool 1 Attic 6 376 ft2 1 st Floor 94 ft2 Proposed Qn 1st Floor —cfm 56.4 cfm 0.03 0.50 1 1 2 Attic 6 275 ft2 2nd Floor 68.75 ft Proposed Qn 2nd Floor —cfm 41.3 cfm 0.03 0.50 2 2 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May Jun Jul ri Aug �Xj Se [ ]Oct Nov Dec Heatin Jan Feb Xj Mar APrMay Jun Jul E ]Au SeP []Oct Nov f X�Dec Ventin Jan Feb X Mar [X A r [ Ma Jun Jul ]Au Se [X]Oct H Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 - 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 1 st Floor Default 8 Ibs/s .ft. 0 ft2 Oft 0.3 2nd Floor Name: Signature: Rating Compant: Date: 7/25/2018 1:09 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD . • ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts,location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location varies 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 5 13. Cooling system: Capacity 48.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 3255 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.555 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.315 14. Heating system: Capacity 48.0 c)Area 7c. 292.6 a)Split system heat pump HSPF 9.0 b)Single package heat pump HSPF 8. Skylights c)Electric resistance COP a)U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 11.0 15.Water heating system c)Concrete,raised(R-value) 9c. a)Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. 11.0 e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 1062. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. 30.0 d)Multizone cooling credit d)Radiant barrier installed 11 d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection. Otherwise,a new EPL display card will be completed based on i d code compliant features. Builder Signature: Date: 07/25/18 Address of New Ho e- 36002 Saddle Palm Way City/FL Zip: . FL Zephyrhills,FL 33541 7/25/2018 1:10:50 PM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Anal Job: 3246A sf ADS Carrier g YSIS Date: 7/25/2018 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Sarasota Bradenton, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (°F) 38 17 Latitude: 27°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0 Dry bulb(°F) 33 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 79 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • 1 Component Btuh/ft2 Btuh % of load Walls 5.2 6768 28.6 uas Glazing 28.9 4556 19.3 wall nfiltration Doors 22.5 446 1.9 Ceilings 1.3 1508 6.4 Floors 3.1 5823 24.6 Infiltration 1.7 2558 10.8 Ducts 2010 8.5 Floors Piping 0 0 Humidification 0 0 Glazing Ventilation 0 0 other Ceilings Adjustments 0 Total 23670 100.0 Component Btuh/ft2 Btuh % of load Walls 2.9 3795 19.0 Internal Gains Glazing 58.4 9212 46.0 walls Doors 19.0 375 1.9 Ducts Ceilings 1.9 2216 11.1 Infiltration Floors 0 0 0 Infiltration 0.4 614 3.1 Ducts 2101 10.5 Ceilings Ventilation 0 0 Internal gains 1700 8.5 Other Blower 0 0 Adjustments 0 Glazing Total 20013 100.0 Latent Cooling Load= 1859 Btuh Overall U-value= 0.112 Btuh/ft2-°F Data entries checked. ` -Fk =1ghtsoft- 2018-Jul-2513:58:14 ^�^•k Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Buildin Anal SI$ Job: 3246A sf ADS Carrier g Y Date: 7125/2018 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Sarasota Bradenton, FL, US Indoor temperature ff) 70 75 Elevation: 26 ft Design TD (°F) 38 17 Latitude: 27°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0 Dry bulb(°F) 33 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 79 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftz Btuh % of load Walls 3.6 4072 30.3 ucts Glazing 28.9 3827 28.5 wall Doors 0 0 0 Ceilings 1.2 1650 12.3 nfiltration Floors 1.9 9 0.1 Infiltration 1.7 2161 16.1 Ducts 1727 12.8 other Piping 0 0 Ceilings Humidification 0 0 Ventilation 0 0 Glazing Adjustments 0 Total 13445 100.0 • • i Component Btuh/ft2 Btuh % of load Walls 2.8 3171 18.1 Glazing 50.7 6724 38.4 walls Internal Gains Doors 0 0 0 Ceilings 1.8 2424 13.8 Floors 0.9 4 0.0 Ducts Infiltration 0.4 518 3.0 Ducts 1814 10.4 Ventilation 0 0 Infiltration Internal gains 2855 16.3 other Blower 0 0 Adjustments 0 Glazing Ceilings Total 17510 100.0 Latent Cooling Load= 3279 Btuh Overall U-value= 0.097 Btuh/ftz-°F Data entries checked. =1Qhtsc ft- 2018-Jul-25 13:58:14 MCA ^�°° �°°w yam. Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Summary Project •' Job: 3246A sf ADS Carrier Date: 7/2512018 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • i For: Lennar Homes Notes: Design Information Weather: Sarasota Bradenton, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 63 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21659 Btuh Structure 17912 Btuh Ducts 2010 Btuh Ducts 2101 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23670 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20013 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1381 Btuh Ducts 478 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1880 1880 Equipment latent load 1859 Btuh Volume(ft') 16486 16486 Air changes/hour 0.23 0.12 Equipment Total Load (Sen+Lat) 21871 Btuh Equiv.AVF(cfm) 62 32 Req. total capacity at 0.85 SHR 2.0 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER. j Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.034 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.92 Capacity balance point= 33 OF Backup: Input= 7 kW, Output=24093 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� -Fk wrightsoft- 2018-Jul-25 13:58:14 ^�^•�a• a•^- - Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Summary ProjectSummary Job: 3246A sf ADS Carrier Date: 7/25/2018 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Notes: Design Information Weather: Sarasota Bradenton, FL, US Winter Design Conditions Summer Design Conditions Outside db 33 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 38 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 63 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11718 Btuh Structure 15696 Btuh Ducts 1727 Btuh Ducts 1814 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 13445 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17510 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2867 Btuh Ducts 412 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft') 1375 1315 Equipment latent load 3279 Btuh Volume(ft') 10998 10998 Air changes/hour 0.29 0.15 Equipment Total Load (Sen+Lat) 20789 Btuh Equiv.AVF(cfm) 52 27 Req. total capacity at 0.85 SHR 1.7 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER AIR CONDITIONING Trade CARRIER AIR CONDITIONING Model 25HBC524A00300 Cond 25HBC524A00300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.060 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point= 19 OF Backup: Input=4 kW, Output= 13485 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft® 2018-Jul-2513:58:14 Right-Suite®Universal 2018 18.0.16 RSUD5714 ACCk ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Page 2 • i Loads for Multiple Orientations Job: 3246A sf ADS Carrier Date: 7/26/2018 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson i Project • • For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Sarasota Bradenton, FL, US Indoor temperature(°F) 70 75 Elevation: 26 ft Design TD (°F) 38 17 Latitude: 27°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0 Dry bulb(OF) 33 92 Infiltration: Daily range(°F) - 14 ( L ) Wet bulb(°F) - 79 Wind speed (mph) 15.0 7.5 Front Door North' Northeast East Southeast South Southwest West Northwest Sensible Load(Btuh) 17510 16929 15755 17721 19007 17964 14744 17178 Latent Load (Btuh) 3279 3279 3279 3279 3279 3279 3279 3279 Total Load (Btuh) _20789 20208 19034 21000 22286 21243 18022 20457 Heating AVF(cfm) 800 800 800 800 800 800 800 800 Cooling AVF (cfm) 800. 800 800 800 800 800 800 800 Building Orientation Cooling Load 25000 2000 r m v 0 1500 J m C i O U m 1000 0 F- 5000 0 N NE E SE S SW W NW Direction Front Door faces Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces South Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -*- wrightsoft® 2018-Jul-2513:58:14 ,L ��R•k• �•� ��mwm Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCA ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Loads for Multiple Orientations Job: 3246A sf ADS Carrier Date: 712512018 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling • I 8950 New York ave,Hudson I Project • • For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Sarasota Bradenton, FL, US Indoor temperature(OF) 70 75 Elevation: 26 ft Design TD (OF) 38 17 Latitude: 270N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 33.1 63.0 Dry bulb(OF) 33 92 Infiltration: Daily range(OF) - 14 ( L ) Wet bulb(OF) - 79 Wind speed (mph) 15.0 7.5 Front Door .-North Northeast East Southeast South Southwest West Northwest Sensible Load(Btuh) r- 20013 18586 15306 17921 18864 18294 16020 18578 Latent Load (Btuh) .1859 1859 1859 1859 1859 1859 1859 1859 Total Load (Btuh) __21871 20445 17165 19780 20723 20153 17879 20437 Heating AVF (cfm) = 800 800 800 800 800 800 800 800 Cooling AVF (cfm) -800 800 800 800 800 800 800 800 Building Orientation Cooling Load 2500 • I 20000 L Qt 0 1500 J O1 _C O O U m 10000 0 H 5000 0 N NE E SE S SW W NW Direction Front Door faces Current Orientation: Front Door faces North Highest Cooling Load: Front Door faces North Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ® -�- wrightsoft- 2018-Jul-2513:58:14 Aurt t•/B ne va 4tluny ampM Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ACCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: 3246A sf ADS Carrier Date: 7/25/2018 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling- 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.3°F Sensible gain: 20013 Btuh Entering coil DB: 75.6°F Outdoor design WB: 78.8°F Latent gain: 1859 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 21871 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 102% of load Latent capacity: 3600 Btuh 194% of load Total capacity: 24000 Btuh 110% of load SHR: 85% Heating • • Design Conditions Outdoor design DB: 32.5°F Heat loss: 23670 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18859 Btuh 80% of load Capacity balance: 33 °F Supplemental heat required: 4811 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 7.1 kW 102% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. -wrightsoft® 2018-Jul-25 13:58:15 CC a�•�a= mow- ------ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: 3246A sf ADS Carrier Date: 7/25/2018 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson- Project Information I, For: Lennar Homes Coo-ling -Equ'ipment Design Conditions Outdoor design DB: 92.3°F Sensible gain: 17510 Btuh Entering coil DB: 75.5°F Outdoor design WB: 78.8°F Latent gain: 3279 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 20789 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 117% of load Latent capacity: 3600 Btuh 110% of load Total capacity: 24000 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 32.5°F Heat loss: 13445 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18852 Btuh 140% of load Capacity balance: 19 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 4.0 kW 100% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 1 wrightsoft® 2018-Jul-2513:58:15 •-I.......— Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 XCK ..pment\3246 sf ADS template 2,2 ton Carrier.rup Calc=MJ8 Front Door faces: N 1.02.0 t - D-1•Q1 3 : PAD= 00.4 9:9 t Z LOT TYPE B ' 1YPE q • �\` �- R''az� h' ��� ' ' r r X)o3,.99�.' ��Q PAD=�1�U 1: ca�'�g6 g8� ` •', // / �--- ,. ho. " s 6 h TYPE ' =iQi.i.o ``, 'io .i : . �,� �� 9 .s .�; �, <r EX. POND E1 ,.. LOT s'.. . + " `+.f . < TOB=98.0 y =101.4 �'� � . °� , �`' 1 �9OOYRDFIW=97. 1 TYPE A. .�� ,;� t1 _ ,. �g0' 9. -} 125YRDHW=9&, 'b. ^" ''+.•, i'hx7�:l30 �'\• \``�,\ •' -\Q� `'t `' ry fit' . 1K'�F%iQV.7Q `+� �• •! DLW^93.40F1PAD,NC F=10z, �;: 9s ihoL,t3T 13 NW�93.CJ°' 9 I � RAC •toi.0 PAD=100.0LO .ti - O 1` ,YPE S '+"` 1 ` � �� EXIS PAD'i01�4 O �. h + cp 6- TYP��A �` 1'09.9� ��0 0 �`. 900 �� Q.,gO ,°�. __-fig,` G L( 3t* �10, \ h \ s' '1 Eg g ra ` I �g�a ENGINEERNCONTRACT( • � o , �F; � �. � �19. 2. PAD Et.EV, BUILDING.IN ,1 10o,Ls .LOT. - w f'Afl= Qt2 `�' Oh. 9�.75 �`9•st �Y t t� 70 `` k 3. LOTS REG + :0 % 92 ' ` ` ~ PER FHA' I �� •A.`, - t1� "gg.p5 was' `. 9�• ,, �i ` `,� ? 0 �• PF= '?.90 Zit �-- l g�O SIMILAR Tf 0� \��5 h 60�t� �Oh. O { O r t`t )2 + , `. '. ��'� . THE ABSEI t' -- ` , O `;5 PA --1 oQ:2 j / 4. FOR AL N, 'I � 'oott . F 1O�170 , , l r ---dbc .• i` 9 +.�g�� �t Qf / ��y O 6?,�-_ BEYOND T ' �Jf� THE APPR PAS.-i o t o 6 /q'r y/�g6 f r TYf F A +,�/ ! r�. Il;`L ',' i g'1 p1" f i c - 1 5. SIDE SWA 'O , � t ' ` __ CONSTRUC . �. Xto . . . 'h,+ .. `. r �' }'a FF=1�A1.40. `�, =z- `. IN. .. ' `, g LOT ' 1. 0 1 1-____ _ _ �, SHALL GR '� '," Ok. '+ Oy. O •', `, I0 , PAI0.7 BELOW N46'-` \' �` k �. � i, L4 1Q$ t HYPE q`, g. �c�o . . --"'__ jE s. R p +�'" pi +`. '+, LOTS, ALL `� ;, ! ' J a' �f' .°" 1 `` ` .� _ -_______ 9$-_--_- , `'I ,1 , 7. FOR TYPI -� �ti. rod f+ r ,* �, _ ___ __ __ � __ g '1`• . . 7'`,. + •-r`- ssNf /.1J + `Q1• 99.` _ (� "_ C� �- g� LOTS, ALL l+ Spy •1 .++ + .� � ',`� /�? f °' ° '-3!`Vf '(� '', "y<--- -. �- .� , \ - :h1 �9 i � F ff°'p�° +�"' r`' /gyp t 6 9 O i �0 r "�.�_ --- 8• FOR TYPI _ �.! ti. u g t BUILDER\• `+``�ti �' �� `' O �t �f`.z,� 'f`h0� +� � "• � �^\ 10+0'4 y..��0�'1 g�`1[' O -6` ,`� g'S°' t � R \.: t t , �f0 3 -� f o o,`b' r$g TO THE F ENGINEER IN MINIMUM ' :\\`�0��` -�-�;' \ \• �' . . ` +r�(? -r� i ��' s '^� i' 1 1 h0 �` 1 t CX19.65 X99.1 .\ .':�:.. \. .. ; ';' , . i t gg,2 10. UTILITIES ; ; 32 THE BASE .\. .. ��',,��>>" ,� :'�' " 'S .REC.T ' �S' L OC :. TED 1N FLOOD • ZONE A, 'AE & X ACCORD/NG TO FEW :R:M. CdMMUNITY PANEL "NO;:. 12101 C .0288E & �2 9 09 C 0289E ELEVATIONS BASED Ot DATED a9f2sf2014 (NAVD88), COtVVERS =__ - 04-26-21-0080-00500-0100 1 Pasco County Property Appraiser Page 1 of 1 i Data Current as Of: Weekly Archive - Saturday, November 3, 2018 Parcel ID 04-26-21-0080-00500-0100 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $26,525 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 36002 SADDLE PALM WAY ZEPHYRHILLS, FL 33541 Just Value $26,525 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $26,525 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $26,525 BLOCK 5 LOT 10 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line ,Use �Description'Zoning Units ;Type .Price :Condition ;Value 1 1 0100 SFR MPUD 6,000.00 SF $4.00 1.00 $24,000 2 i 0100 i SFR ! MPUD 6,312.00 SF $0.40 1.00 $2,525 Additional Land Information FEMA - - - Acres 0.28 Tax Area 30SI Code -- Residential Code SLVRLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line Description Year ;Units Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year;Book/Page ;Type DOR Co_ de;Condition'Amount 10/2018 9811 / 1078 Warranty Deed ! 05 Vacant Multi-Parcel Sale 03/2017 j9356 / 1223 ;Mineral Rights or Royalty Tra_nsfe_ri 05 Vacant 'Multi-Parcel Sale_ 09/2011 ;8606 / 3376 Warranty Deed 05 Vacant :Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126040080005000100 11/5/2018 Lennar Homes-36002 Saddle Palm Way 4,093 sq ft Column IS SQ. FEET PRICE MAIN OR LIVING: 4,093 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 461,076.45 FEE SHEET $ 2,350.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 2,472.00 ELECTRICAL: $ 528.75 PLUMBING: $ 352.50 MECHANICAL: $ 246.75 SUB-TOTAL $ 3,600.00 TOTAL $ 3,600.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,153.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,754.19 Single Family Dwelling Plan Review Coininents l: F.F.E. shall be a.minim. of 8"above"the road.elevation,and an engineered site plan. " 2.. "Lots shall-be graded.to comply withR401.3 of theF.B:C. " 3.= ;Compaction test required if24"or m6reof-fill dirt is brought in at any one place: 4: "Tie in.survey-required before pouring concrete.. 5.- Driveways:require-a R:Q:W use permit. Alto sides of driveway thru the sidewalk slialthave = ` expansion material: 6. All setbacks.shall be met.. 7.: ;All property markers shall be uncovered and marked.at time'of first inispection: 8 All A:D:A:requirements shall be met. 9. "No:electric;plumbing,'mechanicaL_or framing shall be covered without an:inspection.and approval"first. 10.A11 Garages shall comply: C:with,section R302,6:of the.F.B. (Fire Separation). 11: Appliances:shall not.be installed in,a location ivliere subject to"mechanical"damage"unless r9tedted b a roved barriers. M303-.4 p. . Y pp . of."the.F.B:C. 12. Water heaters shalt comply with section:P607.3"of the F.R.C. - 13. Foundation supports-for.A/C-units shall be raised at Jeast 3" above finished grade.. M13083 - - 14.Return ai.r in all-bed roozns..F.B.C. NI1620:4 15. Smoke detectors are.to be installed in accordance-with"R3111 of the:F.B.C. l b:"All glazing requirements"are.to be in accordance with-R308-.4 of the F.B.C. 17. All means,of egress are to.be' in4c'cordance with R311::of the F;B.G. . 18. "Green gypsum board $Ball not be used as a backer.in:showers or tubs. R702.4:2T.B.C: " 19.Combination-type AFCI breakers are required:at all,locations requiring"an AFCI,type breaker: 20*-Carbon monoxide alarms will be required in-row ow construction"that-uses fossil_-burning heating or appliances organ attached garage . They shall be installed in accordance ply- g g Y with the F.B.C: p g� . i p . .. 2 L'All lumbin" mechanical -and.electrical shall be se "arate""from unit.to unit: 'This:includes all - underground plurribing and electric, 22. All 2616:N.E.C. Codes.will be enforced". 23:;Tamper= Resistant Receptacles in accordance with 406.11�of the 2016 N.E:C 24"-Ah accordance-.with"the Land..Development Code' .lots.shall be sodded"before final at least""10 feet around:the structure. 25. Blower door test and'blown in insulation card shall be provided before C.-O. . 26.A copy ofthe enemy cacls.shall be with permit"at all times. 27. Copy of final insulation report shall be:provided.witli:permit before.rinab F.F.E.-Finished Floor-Elevation FB.C-Florida Building Code 6th Edition R.O.W-Right ofway A:D.A:-Americans with Disabilities Act N.E.C.-National Electric Code(2011)