Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-20431
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20431 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20431 Issued: 11/06/2018 Address: 36024 SADDLE PALM WAY Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 14,869.19 Subdivision: SILVERADO Amount Paid: 14,869.19 Date Paid: 11/06/2018 Parcel Number: 04-26-21-0080-00500-0110 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 V g� Inspections uired FOOTER 2ND ROUGH PLUMB I INSULATION CEILING FOOTER BOND DUCTS INSULATED S ER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. J/ �gn Oil I�j &__ f"�* OR IG A PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 04-26-21-0080-00500-0110 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, November 3, 2018 Parcel ID 04-26-21-0080-00500-0110 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $25,611 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 36024 SADDLE PALM WAY ZEPHYRHILLS, FL 33541 Just Value $25,611 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $25,611 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $25,611 BLOCK 5 LOT 11 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line ;Use Description Zoning Units Type ;Price 'Condition ;Value 1 0100 SFR MPUD 6,000.00 SF $4.00 1.00 $24,000_ 2 0100 SFR MPUD 4,027.00 SF $0.40 1.00 $1,611 Additional Land Information Acres 0.23 'Tax Area; 30SI ! FEMA Residential Code : SLVRLPI Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra_ Features (Card: 001 of 001) Line ,Descrip_t_ion Year Units ,Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/PageType DOR Code_ ;Condition.Amount 10/2018 .9811 / 1078 Warranty Deed 05 Vacant 'iMulti-Parcel Sale 03/2017 9356 / 1223 ;Mineral Rights or Royalty Transfer; 05 Vacant Multi-Parcel Sale 09/2011 S606 / 3376 Warranty Deed 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126040080005000110 11/6/2018 �13-780 0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department i e Received Phone Contact for Permitting L 813 363 __ 2891 Atttttt tttI /Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 36024 Saddle Palm Way LOT# IVIS SUBDIVISION Silverado Ranch Subdivision Ph 2,3,8,4 PARCEL ID# 04-26-21-0080-00500-0110 ,�, (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II✓ II NEW CONSTR e ADD/ALT SIGN Q 0 DEMOLISH rI INSTALL REPAIR PROPOSED USE SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R IF 3406 SQ FOOTAGE 2 HEIGHT 1 Story BUILDING /l VALUATION OF TOTAL CONSTRUCTION n ELECTRICAL $ �--// F PROGRESS ENERGY Q W.R.E.C. �• r AMP SERVICE PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS 14 ROOFING 0 SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA EIYES Do BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200, pa,FL 3 License# I CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road,T44a, FL 3 License# I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayo , FL 34674 3 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N J FEE CURREN I Y/N Address P.O. Box 5308, Bayone , L 34674;�5308 License# I CAC058062 ,OTHER COMPANY SIGNATURE REGISTERED Y/ N J FEE CURREN Y/N Address 4211 Shoal Line Blvd, S ng Hill, FL 34607 License# CCC057991 11111111111111111111111 11 11 11 1ltttlllllllllllllllllllllllllllllllllllllllt RESIDENTIAL Attach(2)Plot Plans;(2) s of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)workin6 days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW F OTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco',County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND,RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood-Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of"such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority-to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTJCE OF COMMENCEMENT. FLORIDA JURAT(F.S. 7.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn t or affirmed)before me this Subscribed ands n to(or affirmed)-before me this --- LJ-JUI-1 O by Ashlee Callahan 23Jul-18 by Ashlee Callahan Who is/are personally known to me or hasihave preddsed Who is/are personally known to me or hasfhaee predeee# as identification. as identification. Notary Public Notary Public Commission F 8537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Ftl6II:AW.CUMN' IR n�M alscWaO "iyl�tPRly�8111�,��l1l��7` I �,MBi7dIlL�d,��d El B�a�l'IbaTaaXPtlgtu�tyeblllRUl4�pl1 Lennar Homes-36024 Saddle palm Way-3,046 sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 I OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER:1n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 I 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,273.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,874.19 Single Family Dwelling -Plan . an Review.Com, ments 1: F.F.E. shall be a minimum of 8--'-above.the road:elevation and an engineered site plan. -'2.. Lots shall be graded to comply with R401.3 of the F.R.C. .3.. .Compaetion=test required if 24" or more:of-fill dirt is.brought in:at any one place: _ . 4.. Tie in survey required before pouring concrete. 5.: Driveways:require a R.O.W.use permit: A114:sides of driveway thru the sidewalk shall have- . - . . expansion material: 6.. All setbacks shall be met:. . .7. All.property markers shall be uncovered:and marked at time of first inspection: 8:: All A.D.A. requireiiients shall be met._. 9.. No:electric;plumbing,:mechanical; or framing shall be.covered without an inspection and approval-first. 10.,All Garages shall,comply with,section R302.6 of the F.B.C.:(Fire-Separation).. 11. A' liances:shall not be installed in:a location where subject to mechanical damage finless protected by-approved barriers-. M303.4 of the F.B:C 12. Water heaters shall-comply:with section P607.3 of the F.B.C: 13. Foundationsupparts for.A/C shall be raised at least 3"above finished grade.. M1308,1. . . . . '14.Return air in all,bedrooms. F.B.C. M,I620:4:: : - 15: Smoke detectors are to be installed in' accordance with R313.1 of the F.B.C. 16:.A11 glazing requirements are..to be in accordance with R308.4 of the F.B.C. 17. All means,of egress are to be in:accordance with R311:of the ERG. 18. "Green gypsum board"shall not be used:as a backer.iri:showers or tubs:R702.422.F.B.C, 19,'Combination-typeA.M breakers.are required at all.locations requiring.anAFCltype breaker: 20:.Carbon monoxide alarms will be required in riew construction.that-uses*-fossil-burning heating - :or appliances or;an attached garage.: They shall lie.installed'in accordance with the F.B.C. _ . 21. All plumbing,mechanical,:and_electrical shall.be-separate from unit to unit. This includes all . underground plumbing and electric: 22. Al1-2016.N.E:C. Codes:will be enforced 23:Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E:C 24.:In accordance:.with the Land Development:Code;lots shall be sodded'before final at least 10 . feet around:the structure. .. n irsuaioicd shall rvidedbforeC:O.25. Blowerdotestndlowi 26 copy ofthe energy cacls.shall be with-permit at all flnies. 27'� bo _y of fi�iril insulation report s1iaZZ be:tiroviiZerZ with:taeritiit 15efore.final F.E.E.-Finished Floor Elevation FB.C-Florida Building Code 6 'Edition R.O.W.-Ri t of Way Y A.D:A;,'Americans with Disabilities Act N.E.C.-National Electric Code(2011) SKETCH ONLY SEC._.q4 , TWP_2�6 S, RNG.-11--E- NOT A BOUNDARY SURVEY - PLOTPLAN , BEARING BASIS: LOT 11, BLOCK 5 WEST BOUNDARY OF SUBJECT PLAT BEING N 0235'32!' E SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A-FULL AND ACCURATE N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, PRELIMINARY DRAWING' EASEMENTS AND RESTRICTIONS OF RECORD. THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY UNDERGROUND FOOTER, STEM WALL, AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. II UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. LEGEND: T DO NOT SCALE THIS PRINT. DIMENSIONS AND PROPOSED DRAINAGE FLOW NOTES TAKE PREFERENCE. 00.00) = PROPOSED GRADE cai E-00.00 = EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND + PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO CHANGE AND/OR REVISION. S) ,A T G} CERTAIN DATA SHOWN HEREON BASED ON SN(?- \8 PCP�P) ENGINEERING PLANS PROVIDED BY CLIENT. RADI S POINT STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. 10' UTILITY EASEMENT ON LOT AREA CALCULATIONS LOT = 1_0025-11 SQ. FT. LIVING AREA = 2576 0. FT. (99.25) ENTRY = 57 --SQ. FT. GARAGE = 674 SQ. FT. op COVERED LANAI = N4A -SQ. FT. , NI A7 C3 0 =PATIO -A Q. FT. CONC. DRIVE = !1Q_2SQ. FT. pC(P A/C & CONC PAD = 12 ---SQ. FT. LOT 12 PRIVATE SIDEWALK 0--!—SQ. FT. BLOCK 5 IMPERVIOUS 41 3951 SQ. FT. SOD = 6_074SQ. FT. OFF LOT AREA CALCULATIONS RIGHT OF WAY = 549.99 -SQ. FT. DRIVE APRON =___9_1SQ. FT. PUBLIC SIDEWALK = 27_6SQ. FT. SOD = 183 SQ. FT. PRopOSED TOTALS 60g - fV <�" V0 V AREA =--10-5-75—.10 SQ. FT. GNR 17 DRIVEWAY = A91SQ. FT. 0111 1z SIDEWALK =_3_011_SQ. FT. B\,pry- ' SOD =__.k257 SO. FT. -(100.22') LOT 10 0' BLOCK 5 5 TRACT H DRAINAGE AREA SILVERADO RANCH PHASES 2,3&4 36. (PLAT BOOK 73, PAGE 59) 56.15' Z S 86-14'32" w 00 -104 80) PRM(P) es PLAT (TYP) LOT 31 M LOT 32 �4 BOUNDARY-) IA7A BLOCK 1 10 70 BLOCK I SILVERADO RANCH PHASES 2, 3&4 SILVERADO RANCH PHASES 2, 3 &4 4 (PLAT BOOK 73, PAGE 59) (PLAT BOOK 73,PACE 59) LOT 33 NOTES: di BLOCK 1 1 LOT GRADING TYPE = A 3: SILVERADD RANCH PHASES 2, 3&4 PROPOSED PAD ELEVATION 100.7' �q (PLAT BOOK 73,PAGE 59) LOT 34 FRONT SETBACK = 20' BLOCK 1 SIDE SETBACK = 7.5' SILVERADO RANCH PHASES 2, 3& 4 REAR SETBACK = 15' (PLAT BOOK 73, PAGE 59) PROPOSED: ,600 DESCRIPTION: LOWEST FLOOR ELEVATIONS: 9- LOT 11, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES LIVING AREA: 101.40' U= 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE GARAGE AREA: z ELEVATIONS REFERENCED TO If PUBLIC RECORDS OF PASCO-COUNTY, FLORIDA. 0 NORTH AMERICAN VERTICAL I CURVE I RADIUS I ARC CHORD BEARING I DELTA DATUM OF 1988. MEAN SEA I C1 72 1 55.09 1 22-32' 22.161 449" LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 Project Number: -T7q.-.-,. Feet: 10025.11 f LENNAR HOMES LEGEND: 00 (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CHI= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM*T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED aPIPE. LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U U/P= UTILITY POLE, W/F= WOOD FENCE z Drawn By. 9 JOHN R.BEACH&ASSOCIATES,INC. SMS 0 SURVEYORS AND MAPPERS t 911 WEST ST. PETERSBURG DRIVE Checked By ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 555-8370 Scale: NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 7/18/18 ACS .2 THE ORIGINAL RAISED SEAL OF A FLORIDA S 4ATN DA� W p -5 LICENSED SURVEYOR AND MAPPER o� 9 H JOHIS R 3X a . .0 Revisions: FLORIDA REGND SURVEYOR No. 2984 LB#4493 cn JEFF M. HAR_jI0!EY _E L SURVEYOR & MAPPER No.7123 LV'l 1? %/ SO \ ./ . PAD=100.4 9:9 1\�0.80 �2� i�`. / / / LOT-5 �.� \\ ti�� ��� '` TYPE\\B L07 '14 e ' ''ea• 8 . ' / / POND F ,D-=1.0113 '{ o. 02 ��� EX. \ PAD=1©0.1 - iYI'E A . `\ 9 - \�Q.�` '\ TYPE 1d g 6 " \\`, \ TOB=98.0 >, X10 , 9a. ,,. 1°0. g 6 c, .•\X' 1100YRDHW=97.$ I �25YRDHW- . + •C 1. DLW=.93..40 LOT 6 A0=101.4 _ nJW�93.0 �. PAD GRAC TYPE. A o '���. ��. ` ,o`'� � �� LOT 0.30 `..� 0�`� , LOTS, EXIS ,CPC 99� �` P`AD-i00:0 , ` ��., LEAVING L( gg o- -1g. CONTRACT( 'T\YPE B ENGINEER �- 101.0 'i:OT-� ... ' ti� \ {- +'� 'o�\ 'o'`. 99.00 �' �, - 2. PAD ELEV �° 9.9 0 0 1 1`z BUILDING. TYPE\A.' �.\ O \ �� a� ,\ �6g " �,, 3. LOTS REG e'3, `\ ` t 9.5` . - �o o� �0 J J" J ,. f �� PER FHA I :°P '�, 70 c SIMILAR TE / 1.. F�1.01-90 99 1 ° \\ . 9 .. �� t� 7 J-• J f +o�o�� +Ogg THE ABSEI \` inn LOT. :a 92 ' , � PF- �.�0 u J f �- J J. 4. FOR ALL 94i' ,/ 9g .SOT 1 6� J J-- J BEYOND 1. PAD=100.2 `°' J `-`145 7 THE APPR .6° TY�, B �' 1 9 �• . 1 6� + 5. SIDE SWA CONSTRUC 1 : F•F=10;V0 -- 11 SHALL GR 6 Of1fU ' �,( • g �f BELOW TH PAS?10 10 `� rr J� j�J I TYI�� A f^ 6. FOR iYPI N. � : _ .'� Lola a�7;f. �;� ;`` , tie �6 ` % L_� - "--�-z"a-T _ LOTS, ALL X10 .as b<,fF 1 fad 4b PA' - �� '\� L0 10 1E;A `;f�° r�P`,.�+ +9g• o , L�� -._ "_ ->9, p 7. FOR TYP ` \.� \;l \` `\' . 0� �6 , PAD=100.8 ` tP;_. , E /� --------_ ------- 'l �g� LOTS, ALL ` TYPE A- f 1 `'-- o 8. FOR TYP _ BUILDER ag6 \,\ \' \ �� : �N. p \j'.\ E t9 6 '° 0 b °' q ENGINEER ` ``\ .. `, \ • -..\ . \ . ..• T`,• . � 9. MINIMUM •Q- ' °� g s. 10. UTILITIES \�, X7 ?jj;, 0 1 , 1 ir�,l Q• `,. •. .\`\1\ \.;' `' 10`1: ..6� OSci � �' `Lttt--, ,�,,�o ��,� r ' �0°�` �' THE BAS! \ A 01 . ` ` ' ` ELEVATIONS BASED OI s' `�� •AE & X ACCO.RDING TO FEMA ..' :: PROJECT IS L.QCATED IN FLOOD ZONE A, 89F DATED 0 9/2 612014 (NAVD88), CONVERS :\ : '' .� F.I.R:M. -CbMMUN1TY PANEL :�NO:_: .12101 C 0288E & 12101 C 02 1 PASCO COUNTY, FLORIDA • Permit No. 2-6 // - Date Permitted - —C // �L Builder Name/Owner Name L4�/ Control# County Parcel No. Q 4/, _2�6—2,1—OV,50 d AID SubDiv: 6 t Address/Location c3(0 z3/ k ClassificationfType of Use �� ` �/ D TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 3iO 7' Exempt ❑Yes ❑ No / How Determined (O Impact Fee Amount $. 4 Zone No. TAZ: SCHOOL IMPACT FEE �99 Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt R Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation/Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amou RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the bullding permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY PASCO COUNTY DEVELOPMENT-SERVICES PAS Ah" 8731 Citizens ens Dfive Date;211 2/2019 C0UNT_y- Ro"RmAjvv New PorkRichey,FL 34654. 727-8. 47-2411 NOT A PERMIT Rec'eipt#: -1 9363$0 FEE DESCRIPTION ACdOUNTCOIJE UNITS INVOICE# FEE AMOUNT PAID, RECEIPT# DATE Impact Fee Residential Solid 245031 QO-3290.1 0 1.00 1427702 $60.30 $6Q.30 1830330 -2/12/19, Waste Single:Family TOTAL;& $6b.30 $60.30 Receipt# Paid Bv. Check# CC Huth# Cashier ID Workstation Receipt Date Aifrtt'Paicl 1830330 Check 1155464 'BCCCP50ViJ 02/12/2019 $6030 Total Payments:- $00.40 Pa or Address Phone hone Lennar Homes,,LLC Comments: 36024 Saddle Palm Way --while yg4will'be paying your bill milth Pasco county Development Services,-the full arno6ni.'of'the credit card or'e-check fees,NO7-sh6wn above,is collected by Flrs,tBllllngpayment services. MyRepprts,/reports//PAISCOPROD/PASCO/ReceiptPOS'V§.rpt 2112/2019 Page 1:of 1 J FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606A sf ADS Carrier Builder Name: Lennar Homes 0511 Street: 36024 Saddle Palm Way Permit Office: City of Zephyrhills City,State,Zip: ,FL, Permit Number: �Z$p�3//�� Owner: ' Lennar Homes Jurisdiction: P( Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ftz b.Frame-Wood,Adjacent R=11.0 380.00 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types (2576.0 sqft.) Insulation Area 5. .Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ftZ 6. Conditioned floor area above grade(ftz) 2576 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ftz SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 16.00 ftz SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.372 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.12 PASS Total Baseline Loads: 73.00 I hereby certify that the plans and specifications covered by Review of the plans andHE.S?�2F .. this calculation are in compliance with the Florida Energy specifications covered by this - Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: pave Awfich Before construction is completed W DATE: this building will be inspected for �' � compliance with Section 553.908 a I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: I. DATE: - Compliance requires certification b the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordan a with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 7/26/2018 7:45 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606A sf ADS Carrier Builder Name: Lennar Homes 0511 Street: 36024 Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2576.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.372 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.12 PASS Total Baseline Loads: 73.00 hereby certify that the plans and specifications covered by Review of the plans and T1r1E SZ' ., this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave ,UPich Before construction is completed W1 DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. rG'O OWNER/AGENT: BUILDING OF IC L: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 7/26/2018 7:45 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606A sf ADS Carrier Builder Name: Lennar Homes 0511 Street: 36024 Saddle Palm Way Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611200 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (2576.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.54 159.00 ft2 SHGC: SHGC=0.33 b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.30 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.372 ft. Area Weighted Average SHGC: 0.326 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 72.12 PASS Total Baseline Loads: 73.00 hereby certify that the plans and specifications covered by Review of the plans and THE.ST.q , this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: have Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. COD- "" � .. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: = Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 7/26/2018 7:45 AM EnergyGauge®USA Section R405.4.1 Compliant Software Pagel of 4 i FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 2606A sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2576 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 2576 20608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2576 20608 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 174 ft 0 2576 ft2 ___ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2790 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2576 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 2576 ft2 0.11 Wood 7/26/2018 7:45 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 18 8 8 149.3 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 67 4 8 538.7 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.600000 0 4 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 7 8 56.0 ft2 0 0.600000 0 5 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0 _6 N=>NE Garage Frame-Wood Main 11 31 8 248.0 ft2 0.23 0.01 0 7 E=>SE Garage Frame-Wood Main 11 2 8 16.0 ft2 0.23 0.01 0 _ 8 W=>NW Garage Frame-Wood Main 11 14 6 8 116.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.3 N 16.0 ft2 1 ft 0 in 4 ft 6 in Drapes/blinds Exterior 5 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 E=>SE 2 Metal Low-E Double Yes 0.54 0.33 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 4 S=>SW 3 Metal Low-E Double Yes 0.54 0.33 N 92.0 ft2 1 ft 0 in 0 ft 10 in Drapestblinds Exterior 5 5 S=>SW 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 3 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5 6 W=>NW 5 Metal Low-E Double Yes 0.54 0.33 N 12.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 7 W=>NW 5 Metal Low-E Double Yes 0.54 0.33 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 674 ft2 674 ft2 57 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000305 2060.8 113.14 212.77 .227 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 7/26/2018 7:45 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4 f FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 515.2 ft Main 128.8 ft Proposed Qn Main —cfm 77.3 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar ]A r rj Jun rj Jul rj Au Se Oct [ ]Nov ]Dec Heatin Jan Feb �X�Mar E ]APr f jMa May Jun Jul Aurj Sep Oct [X)Nov X]Dec Ventin Jan Feb X Mar [X]A r [ Ma Jun Jul Aug Se [X]Oct [X]Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ftz Oft 0.3 Main Name: Signature: Rating Compant: Date: 7/26/2018 7:45 AM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 34.8 a)Split system SEER 15.0 5. Is this a worst case?(yes/no) 5.. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2576 d) Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.549 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.326 14. Heating system: Capacity 34.6 c)Area 7c. 215.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c)Electric resistance COP a)U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised(R-value) 9b. 15.Water heating system c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e)Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10B2. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c)Knee walls/skylight walls 11 c. d)Multizone cooling credit d)Radiant barrier installed 11d. No e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection.Otherwise,a new EPL display card will be completed ba d on installed code compliant features. Builder Signature: Date: 07/26/18 Address of New Home: 36024 Saddle Palm Way City/FL Zip: , FL ZeFhyrhills,FL 33541 7/26/2018 7:46:05 AM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Analysis Job: 2606A sf ADS Carrier g Y Date: 7/26/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb ff) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.6 7607 23.6 Ducts Glazing 30.2 6456 20.0 wall Doors 23.5 473 1.5 nfiltration Ceilings 1.3 3231 10.0 Floors 2.9 7385 22.9 Infiltration 2.2 3433 10.6 Ducts 3687 11.4 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 Other Callings Adjustments 0 Total 32273 100.0 • • I RIM Component Btuh/ft2 Btuh % of load Walls 2.8 3784 13.4 walls Internal Gains Glazing 54.2 11597 41.0 Doors 18.4 370 1.3 Ceilings 1.7 4468 15.8 Floors 0 0 0 Ducts Infiltration 0.4 714 2.6 Ducts 3602 12.7 Infiltration Ventilation 0 0 Internal gains 3750 13.3 Glazing Blower 0 0 Ceilings Adjustments 0 Other Total 28284 100.0 Latent Cooling Load=3245 Btuh Overall U-value= 0.095 Btuh/ft2-°F Data entries checked. -�- wrigF�tsoft® 2018-Jul-26 07:50:40 ^�^• d,;•w�-+�-P Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..equipment\2606 sf ADS template 3ton Carrier.rup Cale=MJ8 Front Door faces: N Project Summary Job: 2606A sf ADS Carrier ry Date: 7/26/2018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 28586 Btuh Structure 24682 Btuh Ducts 3687 Btuh Ducts 3602 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 32273 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28284 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2481 Btuh Ducts 764 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ft2) 2576 2576 Equipment latent load 3245 Btuh Volume(ft') 21723 21723 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 31529 Btuh Equiv.AVF (cfm) 80 40 Req. total capacity at 0.85 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC536AO0300 Cond 25HBC536AO0300 AHRI ref 9155179 Coil FX4DNF037L AHRI ref 9155179 Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 26 OF Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 30 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F�t- wrightsoft® 2018-Jul-26 07:50:40 .MCA ^•�a• »•^ ��-p Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipment12606 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: 2606A sf ADS Carrier p p Date: 7/2612018 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 28284 Btuh Entering coil DB: 75.5°F Outdoor design WB: 77.3°F Latent gain: 3245 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 31529 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29580 Btuh 105% of load Latent capacity: 5220 Btuh 161% of load Total capacity: 34800 Btuh 110% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 32273 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26344 Btuh 82% of load Capacity balance: 30 °F Supplemental heat required: 5929 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets all requirements of ACCA Manual S. wrightsoft® 2018-Jul-26 07:50:40 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipment\2606 sf ADS template 3ton Carrierrup Calc=MJ8 Front Door faces: N Lennar Homes-36024 Saddle Palm Way,3,046 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 ' FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,268.35 PARK IMPACT FEES 1 $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,869.19 NNU�|NNKN�UN8N0NU0N �W 2018184336 . — ���: / ���°^�~--- ,�00.00 ' . ' =� `DS` 0100 � �IT: ��mr� ~" a.o'NEzL.pxo.pusou CLERK $ COMPTROLLER .10/31 ^ Of I OR 13K 913� �� � Pin- ����� � - Permit No. Parcel ID No 04-26-21-0080-00500-0110 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713.Florida Statutes, the following information is provided in this Notice ofCommencement: I. Description oxProperty: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 05 LOT 11 Street Address: 36024 Saddle Palm Way Zephryhills FL 33541 u. General Description of Improvement Single Family Residence Pool Screen Enclosure I Fence 3. Owner Information: LennorHoman LLC Name 4600 W Cypress St. Ste 200 Tampa FL�336O7 ^oomxs um/ State Interest inProperty: Name of Fee Simple Titleholder: N/A (if other than owner) Address city State 4. Contractor: Name 4600 W Cypress St, Ste 200 Tampa FL^33GO7 auumss City State Contractor's Telephone No.: 813.574.5700 a Surety: Name Address city State Amount mBond: Telephone No.: . o Lender: Name Address city � State - Lender's Telephone wu.: r Persons within the State of Florida designated by the owner upon whom notices m other documents may be served as provided by Section 71n13(1)(a)(7).Florida Statutes: Name Address city State Telephone Number m Designated Person: 813.574.6700 u. m addition mhimself,the owner demicinateu N/Ao[ � to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes. Telephone Number nf Person orEntity Designated uyOwner: V. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE m8THYOUR LENDER'mRAw�rTcx*w�~�EFORE COMMENCINGFIRSTVO��x��R RE�OR IF �NG'YOUR NOTICE OF COMMENCEMENT. -^-~' ^'^~'-IN~~ ' ,CONSULT° STATE OF FLORIDA COUNTY OpPINELu\a Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before mothis 23 day of March —by Steve Robert Smith s Vice President (type ofauthority,_ta_gjfflRZr,trustee,attorney in fact)for Personally Known N OR Produced Identification E] NQffr`y Sicinature Type of Identification pmuum:u wamerr—in0 ��||�8 l|eraD Verification pursuant m8aoUonV2.5un.Florida Statutes. Under penalties nvpeUuw.|declare that|have read the foregoing and that the facts stated in it are true to the best mmy knowledge and belief. COMIT111810111#FF 085837 Signature of Natural Person Signing Above wodotumcsmusfoxn, ` I % � o City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: � Date Received: Site: 3 N 0 2- -add L , f A-lm 11-11-7 Permit Type: ✓L � ? S - Approved w/no comments:❑ Approved w/the below comments. ? Denied w/the below comments: ❑ I This comment sheet shall be kept with the permit and/or plans./00 / f-(f-, Kalvin S itz - lans Examiner Date on actor and/or omeowner (Required when comments are present)