18-20444
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20444 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20444 Issued: 11/13/2018 Address: 6756 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 14,291.69 Subdivision: SILVERADO Amount Paid: 14,291.69 Date Paid: 11/13/2018 Parcel Number: 05-26-21-0100-01100-0010 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT APPLICATION FEES BUILDING FEE 1,477.49 ELECTRICAL FEE 309.38 PLUMBING FEE 206.25 MECHANICAL FEE 144.38 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 [2 Inspections Required FOOTER 2ND R UGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first rinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER DR Horton Inc-6756 Wagon Trail St-2,362 sq ft Column Es SO. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 1,375.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,477.50 ELECTRICAL: $ 309.38 PLUMBING: $ 206.25 MECHANICAL: $ 144.38 SUB-TOTAL $ 2,137.50 TOTAL $ 2,137.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER:1 n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,690.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,291.69 ram/�jnU�or��uu City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: / Site: Permit Type: 1� �2- Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: M i � te X sh tV shall be kept with the permit and/or plans. - - NOV 7 2.818 Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) PASCO COUNTY, FLORIDA Permit No. �6Z Z Date Permitted — — Builder Name/Owner Name Control#' County Parcel No. 65-2G-2-(-6100-01100-0I010 SubDIV: S loeradb Address/Location cS 11)&0eAL d� Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 21 3 6 2- Exempt ❑ Yes ❑ No II How Determined Impact Fee Amount $. 3�p 32' Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ � Z� (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7��•sb Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amoun RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By Id NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing' . the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY D.R. Horton 6756 Wagon Trail St.-2,362 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 1,375.00 ADDRESS $ 40.00 DRITEWAYJ $ 40.00 BUILDING: $ 1,482.50 ELECTRICAL: $ 309.38 PLUMBING: $ 206.25 MECHANICAL: $ 144.38 SUB-TOTAL $ 2,142.50 Public Fee 1% TOTAL $ 2,142.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,695.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,296.69 05-26-21-0100-01100-0010 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Tuesday, November 6, 2018 Parcel ID 05-26-21-0100-01100-0010 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $2,723 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6756 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,723 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,723 See Plat for this Subdivision Taxable Value $2,723 SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B PB 77 PG 079 BLOCK 11 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) i Condition _Line 'Use ;Description'Zoning 'Units !Type .Price ;Value 1 j 0100 SFR MPUD 16,807.00 ; SF $0.40 1.00 $2,723 Additional Land Info_r_m_a_tion Acres 1 0.16 !Tax Area; 30SI FEMA Residential Code NEWSUBB Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line !Description Year ;Units ,Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/YearBook/Page ,Type POR Code.Condition'Amount 11/2018 19813 / 3320 i Warranty Deed 05 Vacant IMulti-Parcel Sale 05/2017 ;9535 / 0546 } Certificate of Title 05 Vacant !Multi-Parcel Sale 11/2016 19462 / 0384 ;Mineral Rights or Royalty Transfer; 05 ! Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050100011000010 11/9/2018 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site a plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt'is brought in at any one place. 4. Tie in s.urvey required before pouring concrete.. .6. Driveways require ak.O..W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material.- 61 All setbacks shall be met: 7. All property markers shall be uncovered and marked at time of first inspection. 8, All A.D.A, requirem-tints shall be met. 9. No electric,plumbing,mechanical,or framing shall be covered without an inspection and approval first. 10,All Garages shall comply with section R302.6 of the F.B.C,-(Fire Separatioon). 11. Appliances shall not be installed in a location where sub ed to mechanical damage unless protected by approved barriers. M303.4 of the F.B:C 12. Water heaters shall comply with section P607.3 of the FRC. 13. Foundation supports for A/C units shall be raised at least 3"above finished grade. M1308,1 14. Return air in all bedrooms. F.B.C. M1620.4 15, Smoke detectors are to be installed in accordance with R313.1 of the F.P.C. 16. All glazing requirements are to be in accordance with R308.4.of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18."green gypsum board shall not be used as a backer.in showers or tubs.R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new constniction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing,mechanical, and electrical shall be separate from unit to unit, This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23.Tamper:Resistant Receptacles in accordance with 406.11 of the 2016 N:E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25. Blower door test and blown in insulation card shall be provided before C.O. 26 A copy of the en=v cacls shall be with permit at all tin:es 27. Couy of vital insulation-report shall be.provided with.perozit before final: 28. No fence;.pool or screen enclosure is issued with this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) City of Zephyrhilis Permit Application FaX a1a-Tao-oo21 Building Department • —" ,��':< P�e�2�d d^�'r-'� r°�rig•-' ��^^�`�a c'�.' �""'n Date Received Phone Contact for Permitting - -iTr-r-x I Il�_ Owner's Name5- rs �= Owner Phone Number �! r•� y �• a��. Owner's Address (csi�+�oS���'� �="� '�' �''� �'��^!��''�� '� Owner Phone Number Fee Simple Titlehoider.Name Owner Phone Number Fee Simple Titleholder Address 9 •" JOB ADDRESS V�LI J LOT# SUBDIVISION ✓ .�� PARCEL ID# 1Sp O - b (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE F_9— SFR 0 COMM OTHER TYPE OF CONSTRUCTION • BLOCK 0 : FRAME �� STEEL Q DESCRIPTION OF WORK �"1�'t" i -r��• ' .ck"i Z_ 614)-t 54 j BUILDING SiZE SQ FOOTAGE F 1�L. HEIGHT r-r-r- -z-r-rrm-r-tl-r-ri-i--rr�-c-ci-r-c-s-r rrl-l-a-r4-r-mrr-rrI a A ar- =BUILDING Is b 51 coo I VALUATION OF TOTAL CONSTRUCTION DELECTRiCAL $. _ j COO AMP SERVICE Q PROGRESS ENERGY W.R.E.C. OPLUMBING $ .}l,3 00 , =MECHANICAL Is 51 co C) VALUATION OF MECHANICAL INSTALLATION =GAS EE" ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS 109.90 ^ FLOOD ZONE AREA OYES NO -C-+C-- -i-i--0- -II-i-'-1--¢-A-F--C-C-C-G-i-i-C-O-i-:-t--C-64r44-4-6r-'*--11 1a-:-1-fe=r¢-1+-i-v-:-i-1-� -"r-�r-9--6, ,:-C-1-- t-1{-t--*- BUILDER 67-11 COMPANY 4 p -�-""�" ae c SIGNATURE REGISTERED Y( N FEE CURRER Y/N. Address %a'��G',Q )-c-1 r-<70,ram License# .FLECTRICIA(J � �m-� *' -- COMPANY G'�e�'`�' o gl d'1c 6-9 SIGNATURE REGISTERED Y/ N FEE CURRER Y/N / - Address License# --� �•' ' PLUMBER �C ��-��^.�'" ...r. COMPANY .SIGNATURE ^� REGISTERED Y/ N FEE CURRER^ Y/N Address f� i13 f � , -i 2l /T��C!� ` License# a( c F 2, A` irS .., MECHANICAL COMPANY SiGNA7l1RE f .-- _ .REGISTERED Y/( N FEE CURRER Y/N Address 1��7,� � / � fix*' f �a a "c1r.•tf1` s License# �!� l' I OTHER COMPANY / _SIGNATURE REGISTERED Y( N FEE CURRER Y/N Address 'd N c� 3'���_4�rt� /�k`€n=- ,�1•' �,a��<�� License# Itltlili► t' litlilltiitiltltililiiitttlilltlllt1111111 •lit"tl• itlli � illlll RESIDENTIAL Attach(2)Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit.Fence installed, Sanitary Facilities&1 dumpster,Site Work'Permit for subdivisions/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,S4ormwater Plans w/Slit Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. *'*PROPERTY-SURVEY required for all NEW construction. Directions: Fill out application completely. Owner�Contractor sign back of application,notarized If over$2500,a Notice of Commemcemeht is required. (A/C upgrades over$7500) ?1* Agent(for the-contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs•if shingles • Sewers - Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ' NOTICE 0F DEED RESTRICTIONS: The undersigned 4nderstundathatthkspeDnitmaybaaub'eotto "deed" Ksstr|otiono", which may ba more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CC0TBACTOB BESP�N8}BlL[T\ES� If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If'-'the contractor is not-licensed as required by |avv, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended�contractor are uncertain as to what licensing requirementsmay apply for the intended work, they are advised to contact the Pasco County Building Inspection Division--Licona|Dg Section at727'847- ` 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) oign portions of the "contractor B\ook. of this application for which they will be responsible. If you,'as the owner sign' �m th� contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privi|aga&in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation |rnpocL Fees and Recourse Recovery Fees may apply Lnthe construction of new buUdinga, change of use in existing bui|dinga, or expansion of existing buildings, as specified in Pasco County Ordinance number 89'07 and 90-07. as amended, The undersigned also.understands, that such fees` as may be due, will be identified at the time of permitting, it is further understood that Transportation Impact Fees and Resource Recovery Fees.must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, ifPaaoo-County Water/Sewer Impactfmeearedue.theymuotbooaid iortopornl|t issuance |n accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation ofvtork is $2.500.00 or more. | certify that |, the appUnant, have been provided with o copy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgricu|ture.and Consumer Affairs. If the applicant is someone other than the"owner", | certify that | have obtained a copy of the above described document and promise in good faith to deliver|tto the "nvvne/' prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this*application is accurate and that all work will ba done in compliance with all applicable laws regulating conatruotion, zoning and land development. Application is � hereby made to obtain o permit to do.work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes,' zoning regulations, and land development regulations. in the jurisdiction. | also certify that | understand that the regulations nfothe'r government agencies may apply to the intended vvorh, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited tcc Department of Environmental Protection-Cypress Bayhendo` Wetland Areas and Environmentally Sensitive [ands, Water/Wastewater Treatment. ' Southwest Florida Water Management District-Wells, Cypress. Bayhoado, Wetland Areao, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative 8erv|nao/Env\ronmanta) Health Unit-Wells, Wastewater Treatment,� Septic Tanks. ' U5-Environmental Protection Agenoy-Asba8toaabatement. ' Federal Aviation Authority-Runways. | understand that the following restrictions apply tothe use of fill: ' Use nf fill io not allowed in Flood Zone"V~ unless expressly permitted. ' If the fill material is to be used in Flood Zone "A''. it in understood that a drainage plan addressing a ''connpanmoting volume" will be submitted at time of permitting vvh}oh is prepared by a professional engineer licensed by the State of Florida. ' If the fi|| material is to be used in Flood Zone "A" in connection with a permitted building using stem vva|| construction, I certify that fill will be used only to fill the area within thestem wall. If fill material is to be used in any area. | certify that use of such fill will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots \eoa than one U\ acre which are elevated-by fill, en engineered drainage plan iarequ|[ed. |f | am the AGENT FOR THE OWNER, \ promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that e separate permit may be.required for electrical vvork, plumbing, aigno, wells, pools, air conditioning, gas' or other installations not specifically included in the application, Apermit issued'shall be uonet�ued to be a license to proceed with-the work and not as authority to vio|o1e, oanue|, a|ter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors 1n plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit in commenced within six months of permit issuance, or if work authorized by the permit)asuspandedor abandoned for a period,of six (G) months after the time the Work (scommenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety /QO> days' end will demonstrate � justifiable cause for the extension. |f work ceases for ninety (BO) consecutive days,the job 'a considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS T[3 YOUR PROPERTY. IF YOU INTEND T0 OBTAIN FlNA0CJ0G, CONSULTWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA (F.S. 117.03) OWNER OR AGENT cnmTRxoro Subscribed and sworn to(orVirme- before me this Subscribed and sworn to(or affirmed)before me this ho W __ ~."^"" Who is/are p.==^. ally known mmvorhas/have Identification.'�'s identification. as ~ ' Notary Public Notary PublicCommission No. ` Commission No. NotaryName of typed,printed or stampedNotary typed,_ ,---_— stamped Notary pUbile State of Flodndaa Michelle moyes 1212112020 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 1, BLOCK 11, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A & 11B NOT YET RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. S.`R- P PG� ON LOT CALCULATIONSLOT 6,807 SQ. AREALIVING — 1.828 SQ. FT.GARAGE Vv PGO� e�P�R\GN yo`6 6a ENTRY = 16 SQ. FT. 'o\ � RtNo� LANAI = 88 SQ. FT. 4 \ 6 PATIO = 0 SQ. FT. mo\ lE6pSg�\ DRIVEWAY = 335 SQ. FT. A/C PAD = 12 SQ. FT. 9\ aB WALKWAY = 27 SQ. FT. y� Yoo IMPERVIOUS = 40% 2736 SQ. FT. PI SOD = 4,071 SQ. FT. \ ' o OFF LOT CALCULATIONS _ z RIGHT OF WAY = 818 SQ. FT. 107.84 1" = 30' DRIVE APRON = 237 SQ. FT. o GRAPHIC SCALE PUBLIC S/W = 250 SQ. FT. \ �• SOD = 331 SQ. FT. o TOTALS �!• d AREA = 7,625 SQ. FT. DRIVEWAY = 572 SO. FT. p? ° 3 SIDEWALK = 277 SQ. FT. �' ....... SOD = 4,402 SQ. FT. 00�'l I 108.9 0.6 a 3 ENS \J 53 O� 1 w lop tS\; �0�>0 0-0 � - \Zo�• AF.eep Ft'o99O � \ \\ �10 t9. \ �'• PN\5\�\4a�o o. \ <to ✓ V, �. LA 4 'o• c?' 9zlu \;v�o�9\\� � 6 k - O_ 107.0 Line Table -I'0 -J \y Line Direction Length 0 n�y�2 \ �O�C'1��\� \ Q` , 1 �•\\, �s C� �'y c\ - �• 1 iiYY L7 N64'39'45'E 45.45' ti��S v,'•5, ' v \ 0 Lp y \ o s�v C1\ 6 ao0 poS Curve Table �Fa OG A. pRp\N Curve Length Radius I Delta I Chord Bearing Chord Cl 4.59' 25.00' 10-31.17' N59-24.06`E 4.58' 01 9T 130 N�yi�\9 S6Dr Jg A \ aG\ '(RPZE CEP PREPARED FOR: \ \\\ \ D•R•HORTON' fs�aNiu�`r �irYr \ \ ZDo BUILDING SETBACKS � FRONT: 20' REAR: 15' SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) LEGEND: SIDE STREET: 15' NOTES: — — — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING - CENTERLINE PT PONT OF TANGENCY PLANS PROVIDED BY THE CLIENT. - - RIGHT OF WAY LINE RP RADIUS POINT PRC POINT OF REVERSE CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 XX.XX PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES �� CONCRETE (P) PER PLAT CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PB PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT THIS IS A PLOT PLAN ONLY POE PRIVATE DRAINAGE EASEMENT PUE PUBUC UTILITY EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26. 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE-X-, AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. A5hA BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N64'39'45'E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC (FIELD DATE:) REVISED: A M E FR I C A N SURVEYSURVEYORIC SEALND OF A FLORIDA LICENSED U R V E Y I N G gg°,°°.,� 1' = 30 FEET , °.�.e;;,�„v yo D191M11ysTgnedbyJamesW.Bo1eman SCALE: 8cM A P P I N G INC. �:�°""•..` DN:cn,lam.W.B4I—N-Amed— a'+` '� Surveying&Mapping,l.c.—H% APPROVED BY: JB ew11=jbo1 man@asmwgmmtemm CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 s*.re a. o rus 180820 LOT 1, 3191 MAGUIRE BOULEVARD, SUITE 200 E"'%'•"°`m''•"' Date:2018A9.2414:11:16-"00' FOR JOB NO. BLOCK 11 ORLANDO, FLORIDA 32803 'J%•^'1 Adobe Aaobat,enlon:11.0.23 THE (407) 426-7979 °'"�nm�mnaw FIRM DRAWN BY.- DSB WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE PLOT PLAN 09 19 2018 JL FORM 1c 405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILMN ,CONSTRUCTM Florida Department of Business and Professional Regulation - Residential.Performance Method Project Na Cali 1828 Elev D Builder Name: DRH Ex res�s�Ho es [AlStreet: U Permit Office: 1' City,State,Zip: Zep yrhilis,FL, Permit Number: ZO Owner: -3 ?y 5 4 j � l� Jurisdiction: Design Location: FL,Tampa County: �� rlda Climate Zone S) i. New construction or existing New(From Plans) 9. Wall Types(1710.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 b.Frame-Wood,'Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2- 10.Ceiling Types (1828.0 sgft.) Insulation' Area 5. is this a worst case? Ne- a.Under Attic(Vented) R=30.0 . 1828.00 ft2• 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 Conditioned floor area below grade(49 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(166.5 sgft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356 . a. U-Factor: Dbl,U=0.34 126.50 ft2 SHGC: SHGC=0.31' b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (1828.0 sqft.) Insulation Area a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 . 1828.00 ft2 EF:0.950 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat x Total Proposed Modified Loads: 61.27 ���� Glass/Floor Area: 0.091 Total Baseline,Loads: 61.29 I hereby certify that the plans and specifications covered by Review of the plans and © 114E ST,q � this calculation are in compliance with the Florida Energy specifications covered by this �+IV M I Code. calculation indicates compliance p„r`� with the Florida Energy Code. PREPARED BY: �1"tL . . .,,�,. Before construction is completed DATE: ° x-ar-fR r-� a this building will be inspected for compliance with Section 553.908 hereby certify that this building, as designed,is in compliance Florida Statutes: 5c; with the Florida Ener o . G0 OWNER/AGENT: - BUILDING OFFICIAL: DATE: 9 DATE: qnl e S3' - Compliance requires certification by the air handler unit manufacturer that the air hand enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with AN8I/RESNET/1CC 380,is not greater than 0.060 On for whole house.. 8/31/2018 10:13 AM EnergyGauge@)USA Section R405.4.1 Compliant Software- Page 1 of 4 FORM R405-2017 L.ORMENERGY EFFMENCY CODE FOR BU MIN ta: CMSTRUC T M Florida Department of Business and Professional Regulation - Residential Performance (Method # Project Name: Cali 1828 Elev D Builder Name DRH Express Homes Street: '-le, -C Chit Permit Office: City,State,Zip: Zep yrhills,FL, �1 -V Permit Number: Owner: �� ?� 4 f `l Jurisdiction: Design Location: FL,Tampa County: y Z rida Climate ZonelS ) tl 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sgft) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ft2 b. Frame-Wood,Adjacent R=11.0 306.22 ft2 ` 3. Number of units,if multiple family 1 c.N/A' R- ft2 ' 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1828.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft2 7. Windows(166.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 a. U-Factor Dbl,U=0.34 126.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems. 8. Floor Types (1828.0 sgft.) Insulation Area a-Electric Cap:50 gallons a.Slab-On-Grade Ede Insulation R=0.0 1828.00 ft2 EF:0.950 9 b. Conservation features b.NIA R= ft2 None s c•N/A R= - ft2 15.Credits Pstat Total Proposed Modified Loads: 61.27 PS Glass/Floor Area: 0.091 Total Baseline Loads: 61.29 I hereby certify that the plans and specifications covered by Review of the plans and Q -f��E SIP , this calculation are in compliance with the Florida Energy specifications covered by this �( '�.r ^ Q Code.. calculation indicates compliance �` rr„ - `,�� rs1 I with the Florida Energy Code. ti rru gar; '�� �� �Q 9Y PREPARED BY.- ),A Q Lo- Before construction is completed ;� DATE: this building will be inspected for '"'';EPE ` ' compliance with Section 553.908 * ;� I hereby certify that this building, as designed,is in compliance Florida Statutes, 1 with the Florida Energ • ode- Gob 1 OWNER/AGENT,: BUILDING OFFICIAL:. DATE: 9 t DATE: - Compliance requires certification by the air_handler unit manufacturer that the air han er enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4,1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2),. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSURESNET/ICC 380,is not greater than 0.060 Qn for whole house. 8431/2018 10:13 AM EnergyGaugeO USA Section 171405A,i.Compliant Software. Page 1 of 4- FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT :. Title: Cali 1828 Elev D Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1828 Lot# 1/11 Owner Name: Total Stories: i Block/Subdivision: Silverado #of Units: 1 Worst Case: No PlatBook: Phase 7 Builder Name: DRH Express Homes Rotate Angle: 315 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction:- Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family. FL, New/Existing: New(From Plans) Comment: Garage L Face NW CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design'Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS S Number Name Area Volume 1 Blockl 1828 15848.8 SPACES # Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 198.6 it 0 1828 ft2 ---_ 0 0.25 0.75 ROOF i Roof Gable Roof Solar SA Emitt Emitt Deck Pitch { # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2044 ft2 0 ft2 Dark 0.92 No 0.9 No 0 26.6 w ATTIC J' V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1828 ft2 Y N tf (I CEILING # Ceiling Type Space R-Value 'Ins Type Area Framing Frac Truss Type y 1 Under Attic(Vented) Main 30 Blown. - 1828 ft2 0.11 Wood '8131J2018 10:13 AM EnergyGauge4 USA Section R405.4.1 Compliant Software Page 2 of 4 fl.FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below 9 Ornt To Wall]:Vpp Space C V, In P-\/�11.. P-�t;� R- !"a I n Area o 1 N=>NW Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 164.7 ft2 0- 0.6 0 2 E=>NE Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 ft2 0 0.6 0 -3 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 39 8 8 8 343-8 ft2 0 0.6- 0 4 W=>SW Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ft2 0 0.6 .0 5 N=>NW Garage Frame-Wood Main I 1 20 0 8 8 173.3 ft2 0.23 0.01 0 6 E=>NE Garage Frame-Wood Main 11 15 4 8 8 132.9 ft2 0.23 0.01 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NW Insulated Main None. .4 3 6 8 20 ft2 2 N=>NW Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>, changed to As Built(rotated 315,de2rees). Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NW I Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 I ft 0 in 4 ft I in Drapes/blindb Exterior 5 2 N=>NW I Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft' 3 it 8 in 0 ft 0 in Drapes/blinds Exterior 5 3 E=>NE 2 Vinyl Low-E Double Yes 0.34 .0.31 N 15.5 ft2 1 ft 0 in 0ft9in Drapes/blinds Exterior 5 4 S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 I It 0 in 0 ft 9 in Drapes/blinds Exterior 5 5 S=>SE 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 8 ft 0 in 0 ft 8 in Dr I apes/blinds- Exterior 5 6 W=>SW 4 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ft2 1 ft 0 in 0 ft 9 in. Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 430.0128 ft2 430.0128 ft2 46.6 ft 8.67 ft 0 INFILTRATION Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1849 101.51 7190.9 .2941 7 HEATING SYSTEM System Type Subtype Efficiency Capacity Block Ducts I Electric Heat Pump/ None HSPF.8.2 28.6 kBtu/hr 1 sy s#1 8/31/2018 10:13 AM EnergyGaugeG USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts I Central Unit/ None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS. ----Supply ----Return Air CFM 25 CFM25 HVAC# V # Location R-Value--Area Location Area Leakage Type Handier TOT OUT ON RLF Heat Cool 1 Attic' 6 356ft2 Main 40 ft2 Proposed On Main ---cfm 109.7 cfm 0.06 0.60 1 1 = I . TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Mar Apr Ma Jun X Jul Aug Sep Oct Nov Dec He Jan Feb M Apr- May Jun Jul Aug Sep Oct Nov Dec Vel Jan Feb M Apr Ma Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78- 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68- 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 �68 68 68 66 66 MASS- Mass Type Area Thickness Furniture Fraction Space Default lbs/s 0 ft2 Oft 0.3 Main Name: Test Rater Signature: -Rating Compant: Test Rater Date: 8131/2018 10:13 AM EnergyGauge@ USA Section R405..4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1.New home or,addition 1. New(From Plans) 12.Ducts,location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3.No.of units (if multiple-family) 3. 1 4, Number of bedrooms 4. 4 13.Cooling system: Capacity 28.6 a)Split system SEER 5.Is this a worst case?(yes/no) 5. No b)Single package SEER c) Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1828 d) Room unit/PTAC EER e)Other 14.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.390 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.317 14. Heating system: Capacity 28.6 -• c)Area 7c. 166.5 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace,LPG AFUE f)Other 8.20 9.Floor type,insulation level: a) Slab-on-grade(R-value) 9a. 0.0 b)Wood, raised (R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 90. a) Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A.Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2.Masonry(insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16.HVAC credits claimed (Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b) Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed lid. Yes e)Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT. . I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded)in this home before final inspection.Otherwise,a new EPL display card will be compWted based on installed code compliant features.- Builder Sig nature. Date:NS . Address of New Home:^ � � � u' City/FL Zip: Zeahyrhills,FL 35 8/31/2018 10:13:27 AM EnergyGauge@ USA 6.0.02-FlaRes2017F13C 6th Edition(2017)Compliant Software Page 1 of 1 Florida wilding Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Zephyrhills,FL, Mt ANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information'indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelope building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance, R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or,repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in.accordance with UL 907. .R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested.according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 8/31/2016 10:13 AM Energy0auge@ USA -FBC 6th Edition(2017) Compliant Software Page 1 of 5 . MANDATORY.REQUIREMENT'S o (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated.where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1008 of the Florida Building Code,Residential. ❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. SECTION R403 SYSTEMS R403.1 Controls. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 beat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent-supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for-air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403,2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/iCC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. ❑ R403.3.2.1 Seated air handier. Air handlers shall"have a manufacturers designation for an air leakage of no more than.2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure.tested to determine air leakage by one of the following methods: 1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the,test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.. ❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of,carrying fluids above 105OF(41°C) or below 55'F(I WC)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return ❑ pipe Shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systeriis shall be prohibited. - Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515A or UL 515:Controls for such systems EJ shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 8/31/201 8 1 0:13 AM EnergyGauge®USA,-FBC 6th Edition(2017)Compliant Software Page 2 of.5 ' ^ ' WHANDATIORY REQUIREMENTS ~ (Continued)R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed un both the inlets and outlets.External heat traps shall consist of either^commercially available heat trap=~ downward and upward bend of at least o1/2 inches(89mn)in the hot water distribution line and cold water line located as close as possible m the storage tank. n4nn.5.s Water heater efficiencies(Mundato,y)' n�on.5.�1.1'4ummoV co ntrols. Somipewa�� �h � sy stems au tomatic te mperature LJ o(adjustment from the lowest 6othe highest acceptable temperature settings for the intended use.The minimum temperature setting range shall ba from 1oo^Fm14o^F(38rCmGm~o). Rvno����x�hu du�o xmvpa�msn��ma marked shall�l � ' °°"v ~~�' ~~~^r~`d`~~ ^the power—supplied— �� electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types ofservice water-heating systems touo turned off. n�nu5a�m/am~heuinooquipmont VY�o~hm�inoequipmominsmUedmm»�oub���uub�|meet the minimum e��omieunf F� ' ` ` Table C4U4.oin Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria n/Section n4o3.5.s.oJ. �l Solar for domestic hot water production rated by the annual solar mny factor of the systeml The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar stems.*Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, a`d8pcc Smn^ardTM'1.Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and o. Bo installed mpm orientation within^5 degrees cf true south. �7 R«Vn.sMnnhan�o|wpnui�Uon(Mandu� �� , The buUdinOshall unpm wit h me ets�� Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system iv not operating. �l n«nu s.1 Whole-house mechanical ventilation system fan efficacy. When installed m function as a pUn��nuau mechanical �� ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. i Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered byon electronically commutated motor. nonn.6.2 Ventilation air. Residential buildings designed mbe operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. e. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached e nclosed-garages or outdoor spaces adjacent to swimming pools or spas. 3. V ventilation air is drawn from enclosed spano($ walls from which air is drawn shall ho insulated ma minimum ofR-11 and the ceiling shall bo insulated wa minimum ofn19.space permitting,o,R'10 otherwise. ' n403.7 Heating and cooling equipment(Mandatory . ' �l n4037.1 Equipment sizing. Heating and cooling equipment shall ue sized in accordance with ACCA Manual S based onthe equipment loads calculated in accordance with ACCA Manual,J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipmentis installed. TABLER403'6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACy a AIRFLOW RATE MAXIMU Range hoods Any 2.8 cfm[watt Any In-line fan Any 2.8 cfm/watt Any ' go 2.8 qfm/watt Any Bathroom,utility room — For Gt1ofm~z8.3Umin. � ` � When tested in accordance with HV Standard V1s� ' ' 8/3//20810:13 AN EnergyGavge@USA FoCBh Edition(20.17) Compliant Software Page oqf 5 ' RMANDATORY REQUIREMENTS - (Continued) nR403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and sl3all not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. Fi R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.1 5.11mes greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less.than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that'space by one or more of the following options: I A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas, 2. A variable capacity system sized for optimum performance during base load periods is utilized, R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C40.3 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow'melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(1 01C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4t8oC). Fi R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.1 0.1 through R403.10.5. R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switchesor other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance With this section. Exceptions.: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. 1`1403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a.liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,'is from site--recovered energyisuch as from a heat pump or solar energy source,.covers or other vapor-retardant means shall not be required. R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal F] efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool, heaters fired by natural or LP gas shall not have continuously burning pilot lights. 8/31/2018 10:13 AM EnergyGaugeO USA FBC 6th Edition(2017) Compliant Software Page 4 of 5 Ej R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 11 60 jable 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure,compliance.Geothermal swimming pool heat pumps are not required to meet this standard. Fi R403.11 Portable spas(Mandatorg)he energy cons I umption of electric-powered portable spas shall be controlled by the requirements of APSP-14: SECTION R404 . ELECTRICAL POW'ER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 8/31/2018 10:13 AM EnergyGaugq8 USA FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 = AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: V Owner: Jurisdiction: w Design Location: FL,Tampa _ a: COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a seating material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped cellind/soff it shall be aligned with The insulation in any dropped ceilingisoffit the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,.or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawispace Shafts,penetrations Duct.shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Pyttand behind 12112ing and Wring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be.sealed,concealed fire sprinklers shall only be sprinklers _ sealed in a manner that is recommended by the manufacturer. . Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions.of ICC-400. 8/31/2018 10:13 AM EnergyGaugeO USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: ;Jai« riforitiatior: Builder: DRH Express Homes Community: Lot: 1/11 Address: City: Zephyrhills State: FL Zip: L4alg(' Test RBSIIItS Passing-results;must meet erther the Performance P(escrrpfive or ERilVlethoo 1PRESCR1PTtVE METHOE4he b ll•ding'cir=tiwsliing„uciit shah be'.testeii.arid verified as having,ar air`leakage..rate of not exceedmg 7 air oura a ress g . . i;and2 ,'':Chan e a PER>^ORMANCE or ERI METHOD The build ng,or dw,elhng urnt,•shall be tested and verified as Having an air leakage'rate of not exceeding the selected ACH(50)value as shown on Form R405 2tTi 7(Performance}or R406 2017:,(ERl},aectian labeled as iri#ilfratioriy sut%s`ec't n ACFt50: AGH(5©}specr€ied &Oyl,.Gafc(Perf9 ance)orR4Q62077( Rf) 7.t100 �i x 60 _ 15849 Method for calculating building volume: CFM(50) _ Building Volume ACH(50) O Retrieved from architectural plans F] PASS (1)Code software calculated When ACH(50)is less than 3,Mechanical Ventilation installation 0 Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond_the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6..Supply and return registers,if installed at the time of the test,shall be fully open, ,.Testing Companyk s Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 8/31/2018 10:13:44 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of i Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th .Edition Jurisdiction: Permit#: :lob.[nformatiort Builder: DRH Express Homes Community: Lot: 1/11 Address: City: Zephyrhills State: FL Zip: a®uct Leakage Test Reslutss Prescr�pE�ve Method Pprforienance/ERiii�thct System 1 cfm25' t�S£ff! tlVe iVfethftd cfi�n25' Total " ?. {. ) S stem 2 cfm25 =To;;qualify as"subsea'nfia!(y:leak#cee'`,Qri`Total boost:te.!'ess:;tl?an;,or.: Y equal to"0 04 if air handler unit is,tnstalled !f air handler unit,ls,not , System 3 cfm25 tnstalled,Qh Total:must fie less_than or equal to 0 03 Thts testing method meets the_requirerents'in acco"rdance with S'ectiori R403 3 3 Sum of any cfm25 !s the atrh 'YES' Total of all cfm25 ( Performance/ERI Method. cfm26 (out,or Total) To ctualify using�this method, Qn`must not"begreater than the 1828 = Qn proposed duct leakage Qri specified an Form R405 2017 dr R406 2017 Total of all Total Conditioned systems Square Footage h Y Q 9 �� Le kage ,ype"s�tected ort,Farm Qn specrfed on Form R405 2D1}7: -'R405 201t7(EnergyCalc)for Ft4062017 (Energyi✓alc)or R406 2tJt7.:y PASS FAIL Proposed Qn 0.06 Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or(i), Florida Statutes. Testi;i�g Company Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Cade requirements with the selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority:" 8/31/2018 10:13:49 AM EnergyGauge®USA 6.0.62-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page i of i Job- manual S Compliance Report : Entire louse By: Progressive Air Systems, Inc Plan: Cali 1828 5907 Dasher Ct,Port Richey,FL 34668 Phone:727.847-3898 Fax:727-815-3399 License:CAC033669 ....,_:-. �`.6', - _' :�ijsf ' „a'° ,.� "."i,>.Ji .0 ..w;s.�XNi:.<;,,;;,y,..<,�ri�➢>i<*.7Y„,;.5 ;'?,rt For: DR Horton Lot 1 Blk 11 Silverado, Zephyrhills, FL = s < ? e Design,Conditions Outdoor design DB: 9-1.2'F Sensible gain: 21821 Btuh Entering coil DB: 75.4°F Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB:. 62.71F Indoor design DB: . 75.0°F Total gain: 24787 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23272 Btuh 107%of load Latent capacity: 3908 Btuh 132%of load Total capacity: 27180 Btuh 110%of load SHR: 86% `�°��- �•; �; ;ai ;"%',"... :`:'.t,`�":Fiu't!� .y,. "r�-:s.`::.y � ��3-.;'«;.s"ti•''%`�. .z';. .a n �� r?34 Design Conditions Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitASHP Manufacturer: Carrier Model: CH14NB030+FB4CNP030 Actual airflow: 1000 cfm Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 6.6 kW 1070/. of-load Temp. rise: 20 OF Meets are a!I requirements of ACCA Manual S. WM"1 lltSO�` 2018-Aug-3110:17:15• g• Right-SuiteD Universal 2017 17.0-21 RSU25554 Page 1 C0. ...ighlsoft FilesWvress homes\Cali 4EBB 1828.rup Calc MJ8 House Front faces:NW e Load Short Farm Job: L�fl9)!'Yfg�'Htsof' Date: Entire House By: Progressive Air Systems, Iris Plan: Cali 1828 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-8V-3898 Fax:727-815-3399 License:CAC033669 - - r ' r✓p. . .NF—i" For: DR Horton Lot 1 Blk 11 Silverado, Zephyrhills, FL ,a'r•ai;.°^a<",«,:,.;..�.;ayw^,3is.a?i�;x"" :,i.�v�`;�•:;,g`q'� e :.,;2i'>s�.;ea' z' x:k�," ^$ .,,/ �},�§a=^ w;7,1•a" . '».�::�ax �; r, £�, i��..7ttL6< ..7q�'1'sY .�M .� I`»� gj• `Vy Y't�+yx"1.',:e'¢k-d � ' °5�,.�;,+,,.;, ems.#'' �'. *..^�sts=' ,:r`<`>'�;t" � D•. 8. t}-. ,t- '�'E.f`,:.`, 1-..�. �+�," -�""I.r°.'.�;"�. +Q.� ;;:r�";,wa i'-� �xfs�• „�•;"`a ;..r -�`�.r`� �'%„;vai. -',,.,-,�P`�", r�,.°�'a-F..F< .�,,, u...t'".: ,�<;'Ay"'..�`."ame' ^.,r Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50, 50 Moisture difference (gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO30 Cond CH14NBO30 AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh(�7a 470F Latent cooling 7500- Btuh Temperature rise 27 .°F Total coaling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=32 OF Backup: Input=7 kW Output= 22477 Btuh 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Cig AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M bed 194 3196 3505 151 161 living room 270 2891 4027 137 185 kitchen/dining 349 4292' 5695 203 261 bed3 155 1420 1079 67 49 bath2 55 604 278 29 13 bed2 168 3411 2869 162 131 we 21 24 35 1 2 M bath 114. 1276 652 60 30 M wic 66 77 112 4 5 - laundry 39 45 668 2 31 bed4/den opt 169 1866 1320 88 60 A/C closet 19 181 114 9 .. 5 . foyer. 200 1817 1468 86 67 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WC� h tsoFt' 2018•Aug-Aug 10:17:15 Right-Suite®Universal 2017 17.0.21 RSU25554 Page_1 AGCA ,,,ighlsotl FileslE,press homos\Cali 4SBB 1828.rup Calc=MJ8 House.Front faces:NW -Entire House d 1820 21100 21821 1000 1000 Other equip loads 0 0 Equip. @ 1.00 RSM 21821 Latent cooling 2966 TOTALS 1820 1 21100 24787 1000 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Aug-31 10:17:15 ,�� � Wt'IghtSOW Right-Suite@ Universal 2017 17.0.21 RSU25554 Page 2 ,ti' C—N...ightsoft Fites\E)press homes\Cati 4EBB 1828.rup Calc=MJB House Front faces:NW a Project Summary Job: Entire House' By: Progressive Air Systems, Inc Plan: Cali 1828 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898-Fax:727-815-3399 License:CAC033669 ,y'rla, a.'.t.VY' ..4 t*'.e;1`u: we.. ^'^�:ans � ]�. �'i';F'�,'.•t'.'.'S .1'4.,'+ (".,�.` .i�f^�:. , Y�•-_ - .'C:>" ?.aid-.v. W:� v` A:Y. r-.+-:( •r:,c'a.•;;',4,:?,.:`' f:``>'=�r. '£.`�.-: .`M .Z, N,S"¢£''-'. `"`'!:,g :^-C"�'. °-'';.7.:�';^'� � 'Si;.4'�;'s'�•nss:.isi.'n ..t-=-.a.aims fl :., c•. - ,-f- .;., :fa,`r+r.-,+:>JY.,, For: DR Horton Lot 1 Blk 11 Silverado, Zephyrhills, FL Notes- 4z-f; ', s;;;".* = «,t'''`;t»i �;.:; `r,"a:,"�` ?'*`- ,�4; � „r s, .« �N,.:,.:..:�" -i' -t4 i,".;�y 5"S<K? vz :-N.+•a y -,•r�.,,. ..;-y n.«,.- p,.' * .Q.. �. ®<, 'K �f`J"- >2'� x,,.. ".% � Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity .50 % Moisture difference 54 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17539 Btuh Structure 17223 Btuh Ducts 3561 Btuh Ducts 4598 -Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 21100 Btuh Use manufacturer's data y Rate/swing mult,'sptier 1.00 Infiltration Equipment sensible load 21821 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2360 Btuh Ducts 606 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1820 1820' Equipment latent load 2966 Btuh Volume(W) 16012 16012 Air changes/hour 0.26 0.14 Equipment total load 24787 Btuh Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NBO30 Cond CH14NBO30 AHRI ref, Coll FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh - Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfnVBtuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point.=32 OF Backup: Input=7 kW, Output—' 22477 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed- WCiigl1t�01Ft' 2018-Aug-3110:17:15 Right-SuiteO Universal 2017 17.0.21 RSU25554 Pagel ..,ightsoft Files\Express homes\Cali 4EBB 1828-rup Calc MJ8 House Front faces:NW FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summaiy, areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual -completing the compliance report(one page) and an input summary checklist that can be used for field verification(usually four pages1may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ HVAC system sizing and selection based on ACCA Manual,S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO for the Performance Method. ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 8/30/2018 11:47:24 AM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 INSTR#2018189203 OR BK 9815 PG 910 Page lofl 11/0712018 03:56 PM Rcpt:200463810.000.00 Paula,S. O'Weil Ph.V, Pasco County Clerk&Comytroffer Permit No. Parcel ID No V5 -X& -D-1 - D I 00- V It 0.0 - E?ci I C"— NOTICE OF COMMENCEMENT State of Florida county of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following Information is provided in this Notice of Commencement 1. Description of Property. Parcel Identification No. Street Address: :3a5-41 2. General Description of improvement New Single Family Residence 3. Owner Information or Lessee Information if the Lessee contracted for the Improvement: D.R. Horton, Inc Name 19602 Tt-lennm Drive Tampa 33637 Address City State Interest in Property: Fee Simple Name of Fee Simple Titleholder (if different from Owner listed above) Address city State 4. contractor - D-R-Horton, Inc Name 12602 Telecom Drive Tampa 33637 FL Address city State Contractor's Telephone No.: 5. surety: NIA Name Address city State Amount of Bond: s. NIA Telephone No.: 6. Lender N/A Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713,13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive Tampa 33637. FL Address city State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates NIA Of to receive a copy of the I-lenor's Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing i om encement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCOSig;tt,:re lofOw�n s or Lessee's Authorized Officer/Director/Partner/Manager Assistant Secretarv/D,R. Hgrton. Inc Signatory's Title/Office The foregoing instrument was acknowledged before me this_ _day of N cuembor 20 by AS Assistant Secretary (type of authority,e.g.,officer,trustee,attomey In fact)for D.R. Horton. Inc ame of party on behalf of whom instrument was executed). S11(XM-L- - n Personally Known D4 OR Produced Identification[3 Notary Signature a Type of Identification Produced Name(Print) DANA ANNE NAGHTIN Slate 01 1`104a. Notary Public 0661) -GG:(110660 Commission* Z.2020 My,Comm.Explres,Jul 1Z,2020 wpdata/bcs/noticecommencementj. pcOS3048 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6756 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6756 Wagon Trail St(Lot 1) Jurisdiction: Cond.Floor Area: 1828 Cond.Volume: 16452 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1667 Single or Multi Point Test Data ELA: 92 HOUSE PRESSURE FLOW: 1 50 Pa 1667 cfmEgLA: 217 ACH: 6.08 2 0 Pa 0 cfm SLA: .05 3 0 Pa 0 cfm ACH(50)': 6.08 4 0 Pa 0 cfm 'For prescriptive projects,tested leakage must be 5 0 Pa 0 cfm —7 ACH(50). For performance projects, tested leakage must be— the ACH(50) shown on Form 6 Pa cfm R405-2017 for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes o4TIiES1'1j� or individuals licensed as set forth in Section 489.105(3)(0,(g),or(i)or an approved third party.A written report of the results of the test shall be Digitally signed by David Burch signed by the third party conducting the test and a - riq'•_ y Date:2019.03.08 12:32:55 EST provided to the code official. mid Burch, TopBuild Hoe S Home Services,OU, CDD tiyE.fa� � EMAI LAD D RESS=David.Burch Signature: @topbuild.com,C=US Printed Name: David Burch BUILDING OF CIAL: Date: 03/08/2019 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 425260 o PASCO COUNTY DEVELOPMENT SERVICES Q%,j .04 8731 Citizens Drive Date:2/2012019 COUNTY FLORIDAIV— New Port Richey,FL 34654 727-847-2411 "NOT A PERMIT Receipt#: 1822657 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICt,# FEE AMOUNT PAID RECEIPT# DATE Impact-Fee Residential Solid 24503100-329010 1.00 1430275 $56.39 $55.39 .1832657 2/20/19 Waste Single Family TOTALS: $55.39 $66.39 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1832667 Check 87559 540 BWCP06W 02/2012019 $55.39 Total Payments- $55.39 Pavor Address Phone DR Horton 13.41 Horton Circle Arlington,TX 76011 Comments: City of Zephyrhills Solid Waste 6756 Wagon Trail Street Parcel ID: 05-26-21-0100-01100-0010 While you will be paying your bill with Pasco County DeveloprnintServices,the full amount ofthe credit card or e-check fees,NoT shown above,Is collected by First,131111hg payment services. MyReportstreportst/PASCOPROD/PASC0/Rer,eiptPOS_V6.rpt 2/20/2019 Page 1 of 1