Loading...
HomeMy WebLinkAbout18-20445 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20445 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20445 Issued: 11/13/2018 Address: 6764 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est.Value: Book: Page: Cost: 252,110.70 Total Fees: 14,186.69 Subdivision: SILVERADO Amount Paid: 14,186.69 Date Paid: 11/13/2018 Parcel Number: 05-26-21-0100-01100-0020 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,238 SQ FT APPLICATION FEES BUILDING FEE 1,406.09 ELE TRICAL EE 293.63 PLUMBING FEE 95.75 MECHANICAL FEE 137.03 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. 2-6q qS I Date Permitted Builder Name/Owner Name �� � Control#' 20 County Parcel No. __ _ -�JC-2(Q-Zj-D�0���p�SubDiv: V lj Address/Location 7�n.'t ou"O I Q <S7 Classification/Type of Use c5 i�9 ��-}�,nv (� 2(3(Q Z TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Zr�' (n2 Exempt ❑ Yes ❑ No // How Determined Impact Fee Amount $. 3t� 3Z'n Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $��q ��o Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amountr-� RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY DR Horton Inc-6764 Wagon Trail St-2,238 sq ft o umn ts SQ. FEET PRICE MAIN OR LIVING: 2,238 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 252,110.70 FEE SHEET $ 1,305.00 ADDRESS $ 30.00 DRIVEWAYJ $ 45.00 BUILDING: $ 1,406.10 ELECTRICAL: $ 293.63 PLUMBING: $ 195.75 MECHANICAL: $ 137.03 SUB-TOTAL $ 2,032.50 TOTAL $ 2,032.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER:1 n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,585.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,186.69 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received `Ma � Phone Contact for Permitting Owner's Name C�; f- c- Owner Phone Number Owner's Address p •TG�''��'��� '� .�Owner Phone Number Fee Simple Titleholder,Name Owner Phone Number — Fee Simple Titleholder Address l JOB ADDRESS �a ( p LOT# SUBDIVISION c� PARCELiD# a13`/' p' "' olm"C)tl "Loz7b (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN C] DEMOLISH 'INSTALL, • REPAIR PROPOSED USE F 79-- SF COMM OTHER TYPE OF CONSTRUCTION _ BLOCK FRAME STEEL DESCRIPTION OF WORK (v1� -5�v'yje•�'��►� � � �?Se)e��." � ,lEc Z ^� �� G� . . BUILDING SIZE F SQ FOOTAGE HEIGHT 1�r~7—t"rif"1'1"Y's'r—r'rP'r'f�a m s 1 . 9 - =BUILDING $ }�} -- ^ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $. ,� AMP SERVICE 0 PROGRESS ENERGY 0 . W.R.E.C. (�12 uL PLUMBING MECHANICAL $ �} y�pn VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING � SPECIALTY OTHER FINISHED FLOOR ELEVATIONS q FLOOD ZONE AREA =YES NO -8-F-1-D--6-D--D--4-D-i-1-D••D-D-D--i••D--D-F( D-1--0-D-C-D-F-D-*-C-4- --D-i*-i-D- --C-h-:- -F-:--:-9--1--&--D-:-'� BUILDER C. COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address %oflanC7v� /��z�K�.r+i r" g License# [~LECTRtCiAN `:fl e rr,/ COMPANY C=°�en"0'(9��'r�o Ell°C7� P SIGNATURE d` REGISTERED Y/ N FEE CURREN Y/N Address �`d 'ys� = pp"Co� �r License# � i� 71414? ., PLUMBER COMPANY P' (/��'"etfa,l` .. 'b">tifi ,r✓aI/��'rd'%/ � .SIGNATURE REGISTERED Y/ N FEE CURREN Y/N ,r� Address f Ark �r �,a c Y" License# a re MECHANICAL r �-R- COMPANY SIGNATURE f ��'" "` REGISTERED Yl/ N FEE CURREN Y J N Address C}�� f'c�-. '�� ea� cJrtr �}'. License# �� ,� IF OTHER �f,/��..�..---.--.^, COMPANY SIGNATURE / REGISTERED Y/ N FEE CURREN Y/N Address L2_1 3',3 5-4 ?y License# �! i i1i11111t' 1lli1ii111111t11lIlliillllllttltllillllllillll• D111@llllllt RESIDENTIAL Attach (2)Plot Plans;(2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/SM.Fence installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10)marking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for ail new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. *`PROPERTY-SURVEY required for all NEW construction, L4--1-{-4---1-�I-I.i,•-J1-i1...1 S-D-I-S-i�l--i--1..4-.b-i-.l- -3.D--D-i-i-d--2F-F-D--4.i-8.-d-.D--D.*6-.6--1.-i-D-.I-.D-D-.E-&-IUD-i-t-@-i.. Directions: .Fill out application completely. Owner� Contractor sign back of duplication,notarized if over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) *' Agent(for the,contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs•lf shingles • Sewers Service Upgrades A/C Fences (Plot/Survey/Foptage) Driveways-Not over Counter if on public roadways..needs ROW ' NOTICE 8FDEED RESTRICTIONS: The undersigned understands that this permit may beaUbirct1o "d�ed" -Ds� vvhiohnleybon�oreraothcbve than County regu|a�ona. The undersigned amaumamrespnnsibil ^' for oon�pUan"~w�h � aoo�ab|edeed roethobona. � ^ UNLICENSED CONTRACTORS AND CONTRACTOQ RESPO0S|B|UT|ES� If the owner has hired e contractor or coo�actoxotounda�ake work, they may be required toba |imanoed |n accordance with state and local regulations. If-'the contractor is not-licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contnactor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Lice'nsing Section at 727-847- ` 8009. Furthernnora, if the owner has hired a contractor or uontraotona, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. ifyou. aa the owner sign' as' th� contnac1mr, that may be an ind|ob1inn that he is not properly licensed and is not entitled to permitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation Impact Fees and Recourse Recovery Fees may apply tothe construction of now buildings, change of use in exiot|ng buUd|ngn. or expansion of existing bui|dingo, as specified in Pasco County Ordinance number88'O7 and 90'07. as amended. The undersigned also undersbands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees.must be paid prior to receiving a "certificate ofoccupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid-prior to permit issuance. Furthermore, if Pason-CountyVVate�Bovver Impact fees are due,the y must bepaid d t perm|tissuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of Work is $2 5DO bO or more, | certify that (. the applicant, have been provided with a copy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgr|cu|ture.and Consumer Affairs. If the applicant is oonnoona otharthantho"nxvner". | PertKythatihoxaobta|nedanopyoftheabovedesoribeddonurnentondpronnine (ngoodfabhto deliver i1to the "ovvneC' prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this' application is accurate and that all work will bo done in compliance all applicable laws regulating oonstruction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | oarbfv that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating construction, County and City oodao. zoning regulations, and land development regulations, inthe jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to*: Department of Environmental Protection-Cypress Bayheadn, Wetland Areas and Environ mentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management Dintrict-Wa||a, Cypress. Bayhoada, Wetland Areas, Altering Watercourses. ' Army Corps ofEngineona-Saawa||a' Docks, Navigable Waterways. - Department of Health & Rehabilitative Sen/ioes/Envinonnner¢a| Health Un\t4Ne|\s, Wastewater Treatment,-. Septic Tanks. ' U5-Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authority-Runways. \ understand that the following restrictions apply tu the use offill: - Use of fill ia not allowed in Flood Zone"V" unless expressly permitted. ' If the fill nno1aha| is to be used in Flood Zone "X. it is understood that a drainage plan addressing a .,compensating volume" will be submitted at time of permitting which is prepared by a prufesa|onal eng|nea'r licensed by the State nfFlorida. � ' If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall conotrucdon. lne� fi ll ' If fill material is to be used in any araa. | certify that use of such f||| will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent properUaa, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eoa than one (1) -acre which are elevated by fill, an engineered drainage plan is requir,ed. 'if | am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that o separate permit may be.required for electrical vvork, plumbing, aiOna, vve}la` poo|a, air condbion|ng, gas, or other installations not specifically included in the application. /\ permit issued shall be construed to be a license to proceed with-the work and not as authority to vio|ote, oanue|, a|ter, or set aside any provisions of the technical codes, nor shall issuanceof a permit prevent the Building Official from thereafter requiring a correction of errors�in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit ianuanne, or if work author/zed by the permit issuspended or abandoned for a period,of six (6) months after the time the Work is commenced. An extension may be requested, in vvr|Ung^ from the Building Official for a period not to exceed ninety /QO> dayo' and will demonstrate ` justifiable cause for the extension, If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINA0CJ0G. CONSULTWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR CONTRACTOR ,5uo oo u ou(onxm u)before me this Subscribed and sworn tn(or affirmed)before mothis by moucom Who is/are p.ersonany known*omoor has/have produced as identification. as|demification. , . ~, Notary Public Notary pumm 0 Commmomn Commission Name of Notary typed,printed- stamp._ ' ,,-_ printed- -stamped Notary=Public'State of ftrlda My Commission GG 067321 Nx PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 2, BLOCK 11, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A & 11B NOT YET RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PC 1 t� 6p •g\O� O� / 'p,6ou NK' 1 EN, Z r 107. 1" = 30' GRAPHIC SCALE 09 •L. .. 30 0 15 Pi r, 107..3 ..t`` ]DB. '� .3 0 0o° a.iAs � 4Hp \ a0 �O tp pvo ti�',p9 \ ON LOT CALCULATIONS LOT = 6,650 SO. FT. LIVING AREA = 1,672 SO. FT. GARAGE = 432 SQ. FT. <O ENTRY = 38' SO. FT. O JA \ ? LANAI = 6 SO*PATIO = 0 SQ. FT. DRIVEWAY = 378 SQ. FT. �> 00. A/C PAD = 12 SQ. FT. WALKWIMPERVIOUS US = 40% SQ. FT. �K 1N = 2655 SO. FT. SOD = 3,995 SQ. FT. g65°PGE 10���OFF LOT CALCULATIONS RIGHT OF WAY = 900 SQ. FT. s r ^off r r DRIVE APRON = 237 SQ. FT. a. PUBLIC S/W = 250 SQ. FT. �\ SOD = 413 SQ. FT. TOTALS AREA = 7.550 SO. FT. DRIVEWAY = 615 SO. FT. , SIDEWALK = 277 SQ. FT. SOD = 4,408 SO. FT. f•/ �,,,• �'J PRRP���Pt,1P PREPARED FOR: 161101-elwo�1ucMi, BUILDING SETBACKS FRONT: 20' REAR: 15, SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET. 15' LEGEND: NOTES: '— — BUILDING SETBACK LINE PI POINT OF INTERSECTION 1. ELEVATIONS SHOWN ARE PER LOT GRADING - - CENTERLINE PG POINT OF CURVATURE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. — — —— RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NASD 1988 PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE DATUM. PCC POINT OF COMPOUND CURVATURE TYP ==> PROPOSED DRAINAGE FLOW CS CONICRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C) CALCULATED THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PB PLAT BOOK OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK PGS PAGES LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT �•FT. FEDERAL RE FEET F.I.R.M. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.LR.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&U77LITY EASEMENT THIS IS A PLOT PLAN ONLY POE PRIVATE DRAINAGE EASEMENT FLOOD OTE: PUE PUBLIC UTILITY EASEMENT N I HAVE EXAMINED THE F.I.R.M.MAP NO. 12101CO288F. SURVEYOR NOTES: DATED SEPTEMBER 26.2014,AND FOUND THE SUBJECT PROPERTY 1. THE SURVEYOR HAS NOT ABSTRACTED THE APPEARS TO UE 1N ZONE"X', AREAS DETERMINED TO BE OUTSIDE THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT 0.2X ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO OF WAY, RESTRICTIONS OF RECORD WHICH GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE MAY AFFECT THE TITLE OR USE OF THE LAND. LOCAL F.E.M.A. AGENT FOR VERIFICATION, 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF WAGON A5hA 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N64'39'WE, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC REVISED: M E R I C A N ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) SURVEYOR AND MAPPER. SCALE: 30 FEET U R V E Y ts�M I N G DlgllallyslgnedbyJamesW 1 = ,41y� � eoleman c�eM A P P I N G INC. ' "` DN:rn=,amen W BWeman, f APPROVED BY: JB `'�'' Do �scus J� :i�o=Amedran Surveying&Mapping, CERTIFICATION OF AUTHORIZATION NUMBER LB 6393 00, 180820 LOT 2, r� .s� JOB NO. BLOCK 11 3191 MAGUIRE BOULEVARD, SUITE 200 '%s,,, ,r+ m�Ilusplemanpasmmrporate.co FOR ORLANDO, FLORIDA 32803 THE Date:2018.09.220431:49-04'00' FIRM DRAWN BY: DSB WWW 426-7979 .AMERICANSURVEYINGA DMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE PLOT PLAN 09 19 2018 JL D.R. Horton 6764 Wagon Trail St:2,238 sq ft Column SO. FEET PRICE MAIN OR LIVING: 2,238 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 252,110.70 FEE SHEET $ 1,305.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,411.10 ELECTRICAL: $ 293.63 PLUMBING: $ 195.75 MECHANICAL: $ 137.03 SUB-TOTAL $ 2,037.50 Public Fee 1% TOTAL $ 2,037.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,590.85 PARK IMPACT FEES $ 769.56 i SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,191.69 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. 2. Lots shall be gWed to comply with R40.1.3 of the F.B.C. 3. Compaction test required if 24" or more.of fill dirt is brought in at any one place. 4' Tie in survey required before ppuring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk.shall have expansion material. 6. All setbacks shall be met: 7. All property markers shall be uncovered and marked at time of first inspection, 8. All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10.All Garages shall comply with section .R302.6 of the F.B.C._ (Fire Separation). 11.Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the FB:C 12. Water.heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3"above .finished grade, M13.08.1 14. Return air in all bedrooms. F,B.C. M1620.4 15, Smoke detectors are to be installed in accordance with R313.1 of the F B.C. 16. All glazing requirements are to be in accordance with R308A of the F.B.C. 17.All means of egress are to be in accordance with R311 of the F.B.C.. 18. "Green gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker 20. Carbon rtionoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be:installed in accordance with.the F.B.C. 21. All plumbing,mechanical, and,electrical shall be separate from unit to unit, This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced: 23,Tamper: Resistant Receptacles in accordance with 406.11 of the 2016 N:E.-C 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure: 25. Blower door test and blown in insulation card shall be provided before C.-O. 26 A cotes of the enemy cacls shall he with hermit at all times 27. CORE O riial insulation report shall be.provided with.permit before.rnah 28,No fence,.pool.or screen 'nclosure is.issued with this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code Oh Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) FORM R405-2017 "FLORIDA ENERGY EFFICIENCY CODE FOR BUILDiNG CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Na Aria 1672 Eiev C Builder Name: DRH Ex ress H mes Na 3G 4 joy arc. v Permit Office: C � f ht �S City,State,Zip: Zephyrhills,FL,. �� Permit Number: 2-0 Owner: "?���St}\ \ �l Jurisdiction Design Location: FL,Tampa 1 County: iorida Climate Zone 2) i. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int lnsul,Exterior R=4.1 1372.20 ft2 b. Frame-Wood,Adjacent R=11.0 286.00 112 3. Number of units,if multiple family 1 c.N/A 2 R= ft 4. Number of Bedrooms 3 d.N/A R= 112 10.Ceiling Types (1672.0 sqft.) Insulation Area 5. is this a worst case? No a. Under Attic(Vented) R=30.0 1672.00 ft2 6. Conditioned floor area above grade(ft2) 1672 b.N/A ' R= ft2 Conditioned floor area below grade{ft2) c.c. R= ft2 11,Duct s R ft2 7. Windows(182.0 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 334 a. U-Factor: Dbi,U=0.34' 142.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: NIA ft2 SHGC: 13.Heating systems kBtulhr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.701 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (1672,0 sqft.) Insulation Area a. Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.109 Total Proposed Modified Loads: 57.45 g�� Total Baseline Loads: 57.17 �""'' S. 3 hereby certify that the plans and specifications covered by Review of the plans and Tk4iE ST, �` this calculation are in compliance with the Florida Energy specifications covered by this, �� Code. calculation indicates compliance , ''�% "__p'�o` rs+ with the Florida Energy Cade. rrrnrr PREPARED BY: t I Before construction is completed DATE: s-ai-tom this building will be inspected for '.-...I`'s!i'v . compliance with Section 553.908 * ,; I hereby certify that this b ipg, as designed,is in compliance Florida Statutes. ' fir; with the Florida Energ o G©rj WEE OWNER/AGE T: BUILDING OFFICIAL: DATE: DATE: . - Compliance requires certification by the air handler unit manufacturer that the air handier a closure qualifies as certified factory-sealed in accordance with R403.32.1. -Compliance requires an Air Barrier.and insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 8/31/2018 10:32.AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4 i FORM R405-2017 6 LQMDA ENERGY EFF111 ENCY CODE FOR BMUNG CONSTRUCMN Florida Department of Business and. Professional Regulation - Residential Performance Method Project Na Aria 1672 Elev C Builder Name: DRH Express Homes `Street: Ye� rz 1 - Permit Office: ry I City,State,Zip: Zephyrhills,FL,, Permit Number: Owner: . `3_:Is4 . a�`� Jurisdiction: Design Location: FL,Tampa County: Florida Climate Zone 2) C°�X t 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sgft.) Insulation Area t 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 b.Frame-Wood,Adjacent R=i 1.0 286.00 ft2 3. Number of units,if multiple family f c.N/A R= ft2 4. Number of Bedrooms 3 d_N/A R= ft2 10.Ceiling Types (1672.0 sgft.) Insulation Area 5. Is this a worst case? -No a.Under Attic(Vented) - R=30.0 1672.00 ft2 i 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2' I Conditioned floor area below grade(ft2) 0 c.NIA R= ft2 11.Ducts R ft2 7. Windows(182.0 sgft.) Description Area a.Sup:Attic, Ret:Main,AH:Main .6 334 f a. U-Factor: Dbl,U=0.34' 142.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency1 . a.Central Unit 28.6 SEER:14.00 SHGC: SHGC=0 34 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.701 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems. t 8. Floor Types (1672.0 sgft.) Insulation Area a. Electric Cap:50 gallons I a.Slab-On-Grade Edge Insulation R=0.0, 1672.00 ft2 b. Conservation features EF.0.950 b.NIA R= ft2 None c.N/A R= ft2. 15.Credits Pstat Total Proposed Modified Loads: 57.45 Glass/Floor Area: 0.109 PA - Total Baseline Loads: 57.17 1 hereby certify that the plans and specifications covered by Review of the plans and tJ Jjili t this calculation are in compliance with the Florida Energy specifications covered by this . �. , _ gyp. Code, calculation indicates compliance �ff„ with the Florida Energy Cade. i Before construction is completed PREPARED BY: __�tt��..M P j -DATE: x-3Eia this building will be inspected for compliance with Section 553.908 I hereby certify that this bui 'ng;as designed,is in compliance Florida Statutes. tl with the Florida Energ o OWNER/AGE T: BUILDING OFFICIAL: DATE: Lo DATE: . - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires.an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 8/31/2011 8 10:32 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Aria 1672 Elev C Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1672 Lot# 2111 Owner Name: Total Stories: 1 Block/Subdivision: Silverado t,) #of Units: 1 Worst Case: No PlatBook: Phase 7 Builder Name: DRH Express Homes Rotate Angle: 315, Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhllls, Family Type: Single-family FL, New/Existing: New(From Plans) E Comment: Garage L Face NW CLIMATE f Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75. 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block-I 1672 14496.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated i i Main 1672 14496.2 Yes 4 3 1 Yes Yes Yes FLOORS ��ii # Floor Type Space Perimeter R-Value Area Tile Wood Carpet Cj 1 Slab-On-Grade Edge Insulatio Main 192.68 ft 0 1672 ft2 -_-- 0.5 0 0.5 ROOF r• j Roof Gable Roof Solar SA, Emitt Emitt Deck Pitch ' V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 3 t, 1 Hip Composition shingles 1870 ft2 0 ft2 Dark 0.92 No 0.9 No 0 26.6 ATTIC li }} # Type Ventilation Vent Ratio(i in) Area RBS IRCC 1 Full attic Vented 300 1672 ft2 Y N CEILING II F # Ceiling Type. Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1672 ft2 0.11 Wood, 8/31/2018 10:32 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent V y Width Height Sheathing Framing Solar Below 9 Ornt Tn Wn I-Typ. Space Cavity RV111V i- �,1 e Ft In Et In Area RValue EmcUoa---Abscr---Grade--/-, 1 N=>NW Exterior Concrete Block-Int Insul Main 4*0199 18 0 8 8 156.0 ft2 0 0.6 0 2 E=>NE Exterior Concrete Block-Intinsul Main 4.0999 44 0 8 8 381.3 ft2 0 0.6 0 3 S=>SE Exterior Concrete Block-Int Insul Main 4.0999 38 8 8 8 335.1 ft2 0 0.6 0 4 W=>SW Exterior Concrete Block-Int Insul Main 4.0999 57 8 8 8 499.8 ft2 0 = 0.6 0 5 N=>NW Garage Frame-Wood Main 11 20 0 8, 8 173.3 ft2 0.23 0.01 0 6 E=>NE Garage Frame-Wood Main 11 13 0 8 8 112.7 ft? 0 0.23 0.01 0 DOORS Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NW Insulated Main None .4 3 6 8 20 ft2 - 2 N=>NW Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation f=> changed to As Built(rotated 315 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp . Area Depth Separation Int Shade Screening I N=>NW I Vinyl Low-E Double Yes 0.34 - 0.31 N 15.5 ft2 1 ft 0 in 3 it 3 in Drapes/blinds Exterior 5 - 2 N=>NW 1 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ft2 I ft 0 in 4 ft 9 in Drapes/blinds Exterior 5 3 N=>NW I Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 7 ft 8 in 0 ft 2 in Drapes/blinds Exterior 5 4 S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 5 . S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 8 ft 0 in Oft 1 in Drapes/blinds Exterior 5 6 W=>SW 4 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 12 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 7 W=>SW 4 Vinyl Low-E Double , Yes 0.34 0.31 N 1 ft2 1 It 0 i.5.5 n 0 ft 9 in Drapes/blinds Exterior,5 GARAGE Floor Area Coiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 432.1771t2 432.177 f12 49 ft 8.67 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 I Wholehouse Proposed ACH(50) 000386 1691.2 92.85 174.61 .2941 7 HEATING SYSTEM 7 System Type Subtype Efficiency Capacity Block Ducts I Electric Heat Pump/ None HSPF:8.2 28.6 kBtu/hr 1 sys#1 8/31/2018 10:32 AM EnergyGaugo@ USA Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts I Central Unit/ None SEER:1.4 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation Electric None Garage 0.95 50 gal 70,gal .120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name - System Model# Collector Model# Area Volume FEF None None ft2 DUCTS Supply--- ----Return--- Air CFM'25 CFM25 HVAC# V. V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 334 ft2 Main 40 ft2 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling,Fans: Coolin Jul W Au Se Oct an May Jun 9 p Nov J Feb Mar Apr No, Dec Jan Feb M Apr M Jun Jul Se OctDec He� ng X [ ]Aug P Venting Jan Feb M Apr I M 11 Jun r]Jul Aug Sep Oct Nov j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 .78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 -66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68. PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default lbs/sq 0 112 0 ft 0.3 Main Name: Test Rater Signature: Rating Compant: Test Rater Date: 8/31/2018 10:32 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX*= 100 The lower.the Energy Performance Index,the more efficient the home. 1.New home or,addition 1. New(From Plans) 12. Ducts,location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 3 13.Cooling system: Capacity 28.6 a)Split system SEER 5. is this a worst case?(yes/no) 5. No b)Single package SEER c)Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 1672 d) Room unit/PTAC EER e)Other 14.0 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.386 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.317 14.Heating system: Capacity 28.6 c)Area 7c. 182.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights e) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace,LPG AFUE f)Other 8.20 9.Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised (R-value) 9b. 15.Water heating system c)Concrete,raised(R-value) 9c. a)Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c) Gas fired, LPG EF A.Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic i i a. 30.0 b)Cross ventilation No b) Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d) Radiant barrier installed 11d. Yes e)Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code', Energy Conservation,if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed (or exceeded)in this home before final inspection.Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Si nature. Date: g Address of New Home: t City/FL Zip: Zephyrhips:FL �� 8/31/201810:32:30 AM, EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 lorida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERi Methods ADDRESS: Permit Number: Zephyrhills, FL, iWANDATORY REQUIREMENTS See individual code sections for full details. SECTION R401 GENERAL. R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)'requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of-components installed in a dwelling unit.The building official shall verity that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the,requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal enveloT3W building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. the building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones i and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSURESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or ,an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in,accordance with UL 907. EjR402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested.according to NFRC 400 or AAMAI WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 8/31/2018,10:32 AM EnergyGauge@ USA -FBC 6th Edition(2017) Compliant Software Page 1 of 5, MANDATORY REQUIREMENTS a (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal enve(opeor enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be, fully gasketed and any water lines and ducts in the room insulated in accordance with.Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. - Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1 006 of the Florida Building Code,Residential, F1 R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS F-] R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. Ej R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Comm ercial,Provisio ns of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section489.105(3)(f),(g)or(1),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. Fi R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent. of the design airflow rate when tested in accordance with ASHRAE 193. E] R403-.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1 Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pal across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postoonstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and;air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test-shall be signed by the party conducting the test and provided to the code official. FIR403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. F]R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55'F(1 3'C)shall be insulated to a minimum of R-3. ❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall*provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. R403.5.1 Heated Water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in LJ accordance with Section R403.5.1A.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification.of a demand for hot water within the occupancy.The controls'shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems F-1 shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 8/31/20i 8 10:32 AM EdergyGaugA USA FBC 6th Edition(2017)Compliant Software' Page 2 of 5 ' ` . . ` ^ MANDATORTREQUIREM ENTS ~ (Continued) (Mandatory). Storage waterheaters�l n4ox��no�naps not equipped with inte ral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and.outlets.External heat traps shall consist of either a commercially available heat trap or a downward ap m a m inc hes distribution = m �. " ."�w.="" �u�/ � uum m m�mu=cs�a,v"xv »u�eummnetank. R��o Water heater efficiencies(wundatury). �l R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest mthexighoxtrmcoptab|emmpoonu,eoouinno,ortheinoendeduae.Thaminimvmtompoouue setting range shall be from ImrFtu14o^F(no^Ctp60r[). nun�5.s1:o Shut down. A separate switch oru clearly marked circuit breaker shall be provided to permit the power suppliedm electric service systems tobe turned off.A separate valveh ll be providedtopermit the energy supplied w the main bvmer(s)ox combusUon'types of service water-heating systems mbe turned off. F� n403.5.6.2nKat*phemting equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C4n4.ein Chapter 4n(the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipmentinstal|od. Equipment used to provide heating functions as part of combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. F1 n.��s.2.� Su|o,wahe�ing� m systems. Solar systems � wa ter ra ted--� R4o water -heating the system.The solar energy factor m/osystem shall be determined from the Florida Solar Energy Center Directory o Certified Solar Systems.Solar collectors shall be xmmd/n accordance with ISO Standard ooVG.Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and o. on installed mam orientation within 45 degrees of true south. �l R«o3.oMm:han/co/vmmi|uUon(Mondo�n0. The building shall bepom�ed with v*nU|nbun�mmee�the mq�mmon�uf�o -- Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural, Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. �l R400.a1 Whole-house mechanical ventilation system fan efficacy. When installed m function uoa whole-house mechanical ventilation system,fans shall meet the efficacy requirements ov Table R400.uA. ' Exception: VVhemvholo'huvnn mechanical ventilation fans are integral tntested and listed HVAC equipment,they shall bo powered byan electronically commutated motor. F� n40n.V.o Ventilation air. Residential buildings designed to be operated at a positive indoor pressure.or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in 4GHRAEo2.o'Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlsponoo,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. |f ventilation air is drawn from enclosed ($ then the wallsNthe from which air is drawn shall bo insulated mo minimum ofn-11 and the ceiling shall be insulated to a minimum of R-1 9,space permitting,or R-1 0 otherwise. R4on.7 Heating and cooling equipment(0andavory). �l R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipmentmethodologies,|oedoralcu|atodinaccoodanmewithACCAManua|Jnrmh��opp�vedheabnOandcou|ingoa[ov|�|nn �mednnbui�i loads for the directionalmi �� of the bui|dinQ.The manufacturer and model number nv the outdoor and indoo,unit's(if split system)shall be submitted a|nng*oith the sensible and total cooling capacities at the design diti desert*bed in Section R302.1.This Code does not allow designer safety factors,provisionsfor future expansion other factors that affect equipment sizing.System sizing calculations shall not"include loads created"r local intermittent".°c.u.""".ventilation such an standard kitchen d bathroom exhaust New or replacement heating and cooling equipment shall have anefficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLEB4U3'O'1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACYRange hoods Any 2.8 cfm/watt Any FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACy a AIRFLOW RATE'MAXIMUIv ` Bathroom,utility room 90 ` 8Qfm/watt Any � For SI:1 cfn 28.3 Umin. a. When tested in accordance with HV Gtandaudn1G ` . <*��o 8�V�uNN Eno� � � yGauge�UGA 'FBC �� Unn�D�7> Compliant Software ` � Pago�of�� MANDATORY REQUIREMENTS ® (Continued) R403,.7.1.1-Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the'closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's .expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the toad calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached.single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may bei sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. ❑ R403.7.1.2-1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section. R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. Fi R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: I A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections ❑ C403 and G404 of the JECC—Commercial Provisions in lieu of Section R403. ❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10*C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F(4.8'C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.1 0.1 through R403.1 OZ. ❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 rnm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. ❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and an according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at IJ the water surface or a liquid cover or other means proven to reduce heat loss. Exception. Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered, energy,such as from a heat pump or solar energy source,.covers or other vapor-retardant means shall not be required. R403.10A Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal El efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 8/31/261810:32AM EnergyGauge@ USA FBC 6th Edition(2017) Compliant Software Page 4 of 5 R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. DR403.11 Portable spas(Mandatory)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75 percent.of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 8/31/201 8 1 0:32 AM EnergyGaugeO USA -FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Aria 1672 Efev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: x 0 Owner: Jurisdiction: _ Design Location: FL,Tampa c3 COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in.any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the.top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/doorjambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed_edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed fighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall, thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs, be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be. sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids hptwppn fire sl2d and wells or ppilin a.In addition,inspection of log walls shall be in accordance with the provisions of 16C-400.. . 8/3.1/2018 10:32 AM EnergyGaugeO USA FBC 6th Edition(2017)Compliant Software Page'1 of 1 , Enve ope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERi Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Job tnfortnatton ;7u F Builder: DRH Express Homes Community: Lot: . 2/11 Address: City: Zephyrhills State: FL Zip: t 1.E kad4 ,TeSIC R�sulftS , Passing resuJts'rrrust meet either the Fedor' ce,:', Tescriotrve or Rt Method'. F!RBSCft(Pl iUE METH{?L1 The building or dvieIIln ,bhft shall b6 tested'and verified as haying an air ieakagp rate ofxnot exceeding 7 air changes per hour at a pressure of 0,2 inch uy g:(50 Pascals)in.Climate Zones 1 and 2 . t PEt3FORiUlAt3fCE or ERI{METHAD the building or dwelling unit shall be,tesled arid'verified as having an air leakage fate ofi not exceeding ;the selected ACH(%)Yalue as shpwn an dorm Fi405 2p17(Performance),or R406 2017.(ERI),section labeled as:infiltratiop,subsection ACH56. ACFf(�0)specified on`Form r?4C15 2017 4Energy Gaio(P rfomaanceJ or R406 20 t 7(ERJ), : 7.000 x 60 _ 14496 = Method for calculating buildingv olume: CFM(50) Building Volume ACH(50) Q Retrieved from architectural plans ❑ PASS 0 Code software calculated When ACH(50)is less than 3, Mechanical Ventilation installation- 0 Field measured and calculated must be verified by building department. - R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended we-atherstripping or other infiltration control measures'. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall.be fully open. ;Testing`Company Company(Name: Phone:- I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. - Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 8/31/201 8 1 0:32:46 AM Energypauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2617)Compliant Software. Page 1 of 1 -r - wrightsoft9. Manual S Compliance Report Jo Entire House By: Progressive Air Systems, Inc Pla" "a 41EAs 1672 5907 Dasher Ct,Port Richey,FL 34668,Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 x��� :iyc^c��� }' ss .,.s-=. �'-��'%a'�`.';;'i22.q-•,• ;;�b: .. -agog =.t •�°�' a "x x ® For: DR Horton Lot 2 Blk 11 Silverado, Zephyrhills,FL F % Design Conditions Outdoor design DB: 91.2OF Sensible gain: 21334 Btuh Entering coil DB: 76.1OF Outdoor design WB: 77.1 OF Latent gain: 2877 Btuh Entering coil WB:. 63.00E Indoor design DB: 75.0*F Total gain: 24211 Btuh. Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model` CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23532 Btuh 110%of load Latent capacity: 3786 Btuh 1320%of load Total capacity: 27318 . Btuh 113%of load SHR: 86% IN >.r.a x Design Conditions Outdoor design DB: 40.00F Heat loss: 20312 Btuh Entering coil DB: 69.60F Indoor design DB: 70.00F Manufacturer's Performance Data at Actual Design Conditions Equipment type: . Split ASH Manufacturer:: Carrier Model: CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm Output capacity:, 25625 Btuh 126%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 6.4 kW 108%of load . Temp. rise: 20 OF Meets are all requirements'of ACCA Manual S.' . Wf'1 h'�SOft` 2018-Aug-3110:33:15 ^` g Right-Suiteg universal 2017 17.0.21 RSU25554 CA . Page 1 -. E ...ightsoft Files%Express homes\Aria 4EAB 1672.rup Calc=-MJ8 House Front faces:NW, Load Short dorm Jab: F ��igh s�� Date: Entire House By: Progressive Air Systems, IncPlan: Aria 4EAB 7572 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 r�="�:�"'.:. .�h.3�.:J'E�:" .,'r,:£, a�� -•H ",�7�1f,,.,rein,;�3�$ , i r,= J, •.'!+ 't" r, ' -n.- I' 0 tl � ,;'-'r^.;. v,z�x :^`.;"'`F,.-,•-"..t"=,',r ';;.`-�'" ^*s ,:�' S>^�. ,c:`•�:,;:ds .. .emss ,2 `�.r.-`.%,�:r�"" ;ti��,"�r.,,y�: s:� `,,;", �.,,�-."'�.,. :,,.�.� s`• - _.�,. r.,.��.;+�' f���mG�='ice'„ � ._. n.- ,•.�,.�,; r� s.,:.. �1., For: DR Horton Lot 2 Blk 11 Silverado, Zephyrhills, FL d;'.i`°-ri -x�:: t' �`,..r,. ,.��' :3':._f4,, t��Mr,,�;;s.�,,.^,-,y. ""-"'a�:as�y%'•z?' "&,°.< .,ft''.'''�"'�°4`�`'+' ,:���_ ..Sec • -wa'•�y`';��r,,Mh.,:,�' .6�':;G;., i£ .�uy�;,w e..�.�.. .&5.-, ���:.• �t a„�'`; ... Htg Clg Infiltration Outside db (°F) 40 91 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier = Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @a 47°F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 Cfm Actual air flow 1000 Cfm Air flow factor 0.049 cfm/Btuh Air flow factor, 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF 'Backup: Input=6 kW Output=21934 Btuh 100 AFLIE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (Cfm) (Cfm) M bed 237 3345 3280 165 154 dining 202 2812 3947 138 185 greatroom 257 3318 4133 163 194 M wic 49 744 338 37 16 WC 25 372 169. 18 8 M bath 135 1579 845 78 40 kitchen 146 170 1547 8 73 -laundry 42 252 843 12, 40 ' A/C closet 14 16 25 1 1 bed3 154 1615 1675 80 79 foyer. 162 1679 _ 1494 83 70 bath2 60 659 322. 32 15 bed2 166 3751 2716 185 a 127 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. m 2018-Aug-3110:33:16 P, • --rp- 41h so ft Right-Suite@ Universal 2017 17.0.21 RSU25554 Page.1 i Ch ..,Ightsoft Files\Express,homes\Aria 4EA13 1672.rup Cato=MJ8 House Front faces:NW Entire House- d 1647 20312 21334 1000 1000 Other equip loads 0 0 Equip.'@ - 1.00 RSM 21334 Latent cooling 2877 TOTALS 1647 20312 24211 1000 1000 Calculations approved by ACCA to meet all.requirements of Manual J 8th Ed- wt 1 hitSoft' 2018-Aug-31 10:33:15 . .� Right-Suite®Universal 2017 17.0.21 RSU25554,I+CA..., m ightsott Fifes\Express hoes\Aria 4EA6 1672.rup Catc,=MJ3 House Front faces:NW Page 2 Job +Wrightsoft, Project Summary Daft: Entire House BY: Progressive Air-Systems, Inc Plan: Aria 4EAB 1672 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3893 Fax:727-815-3399 License:CAC033669- .,5.a _ _ yf ^T.., < ,e .• ' xf.•: �ra' .a?: --aYe. .N-. T!•:�.,, s�'x-~F''e n"'k"x.a Le;.ti,"'.�".,. k,f.}-.'"'""i>," For: DR Horton Lot 2 Blk 11 Silverado, Zephyrhills, FL Notes: ,15 fl e 'S: Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design_Conditions Outside db 40 OF' Outside db 91 OF Inside db 70 OF Inside db 75 IF Design TD 30 OF Design TD 19 IF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing. Structure 16693 Btuh Structure 16219 Btuh Ducts 3619 Btuh Ducts - 5114 Btuh U Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 20312 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21334 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2231 Btuh Ducts 646 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingq (none) Area(ft2) 1647 1647 Equipment latent load 2877 Btuh Volume(W) 14494 14494 Air changes/hour 0.26 0.14 Equipment total load 24211 Btuh Equiv.AVF(cfm) 63 34 Req.total capacity at 0.75 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary_ Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030**"*A AHRI ref Coil FB4CNP030 - AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow . 1000 cfm Actual air flow 1000 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat.ratio 0.88 Capacity balance point=31 IF Backup: . Input=6 kW, Output,=21934 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft4 2018-Aug-3110:33:16 ACGA Right-Suite®Universal got 17A21 RSU25554 Page 1 _..ightsoft Flies\Express homes\Aria 4EAB 1672.rup Calc=MJB House Front faces:NW FORM R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or-fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page) and an input summary checklist that can be used for field verification(usually four pageslmay be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ NVAC system sizing and selection based on ACCA,Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything_other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 8/31/2018 10:13:15 AM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 INSTR#2018189204 OR BK 9815 PG 911 Page I Of 1 11/0712018 03:56 PM Rcpt:2004639 Rec:10.00 DS:0.00 IT:0.00 TauCa s. O'NeiC PFLD, Pasco County CCerk&ComytrotCer Permit No. e2A Parcel ID No 05~-1-to -DA 0 100 D 1100 4)09kD NOTICE OF COMMENCEMENT State of Florida county of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided In this Notice of Commencement No. L-.o+ c)c-%,t- IL a V_ejr-ac) P hr'Se -7 1. Description of Property: Parcel Identification Street address: &7&4 ZgeN6%ills, F-L 31541 2. General Description of Improvement New Single Family Residence 3. Owner Information or Lessee information if the Lessee contracted for the improvement: D.R. Hotton, Inc Name 19609 TP-Isirnm Drivp Tampa 33637 Address state Interest in Property: Eee Simpip. Name of Fee Simple Titleholder. (if different from Owner listed above) Address city State 4. Contractor: - D-R-Horton. Inc Name 12602 Telecom Delve Tampa 33637 FL j. Address City State Contractors Telephone No.: 5. surety: N/A Name Address city State Amount of Bond: $, N/A Telephone No.: 6. Lender- N/A Name Address city State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive Tammna 33637 FL Address city State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates - N/A Of to receive a copy of the Lienors Notice as provided in Section 713.13(4)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK-OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing Commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Si um of er or Lessee, 4s or Lessee's Authorized Officer/Director/Partner/Manager Assistant Secrdtai dD.R. Horton. Inc Signatory's TdIelOffice The foregoing Instrument was acknowledged before me this=day ofy 201V by ..as Assistant Secreta[y (type of authority,e.g.,officer,trustee attorney in fact)for D.R. Horton, Inc (name of party on behalf of whom instrument was executed). Personally Known C4 OR Produced Identification[I Notary Signature i�r _ a .:n_c, Type of Identification Produced Name(Print) gANA ANNE NAGHTIN Nota ry Public-State of Florida Commission M V Co" �z� Commission#GG 010660 wpdatafbcslnoUcecommencement_pcO53048 My COMM. Expires jul 12,20201 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6764 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6764 Wagon Trail St(Lot 2) Jurisdiction: Cond.Floor Area: 1672 Cond.Volume: 15048 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1364 Single or Multi Point Test Data ELA: 75 HOUSE PRESSURE FLOW: EgLA: 177 1 50 Pa 1364 cfm ACH: 5.44 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm ACH(50)`: 5.44 4 0 Pa 0 cfm .For prescriptive projects,tested leakage must be 5 0 Pa 0 cfm <=7 ACH(50). For performance projects, tested leakage must be<=the ACH(50) shown on Form 6 Pa cfm R405-2017 for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes 04TIST4T` or individuals licensed as set forth in Section 489.105(3)(0,(g),or(i)or an approved third party.A written report of the results of the test shall be Digitally signed by David Burch signed by the third party conducting the test and - r Date:2019.0 Burch, 0=To 19 EST provided to the code official. CN=David Burch,O=TopBuild Home Services,OU, CpDTa EMAI LADD RESS=David.Burch Signature: @topbuild.com,C=US Printed Name: David Burch BUILDING O ICIA r Date: 0 310 8/2 0 1 9 DATE: I Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 425259 PASCO COUNTY DEVELOPMENT SERVICES PAS C 8731 Citizens Drive Date:2/20/2019 O-U N-TY FLORIDA' New Port Richey, FL 34654 727-847-2411 Nu,"T A PERMIT Reoeipt* 1832667 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1430288 $55.30 $55.39 1832667 2/20119 Waste Single Family TOTALS: $65.39 $65.39 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Aint Paid 1832667 Check 877560 540 BCCCP06W 02/2012019 -$5539 Total Payments.: $06.39 Pavor, Address Phone -DR'Horton 1341 Horton Circle. Arlington TX 76011 Comments: City of Zephyrhills Solid Waste 6764 Wagon Trail Street Parcel ID: 05-26-21-0100-01100-0020 I While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by First Billing payment services. Mykeports/reports/IPASCOPROD/PASCO/R6ceiptPOS_y6xipt 2/20/2019 Page 1 of 1 CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS WqDATE PERMITLI_7 '4 - (� The fol owing additions or corrections shall be made before the job . THIS JOB HAS NOT BEEN COMPLETED. will be accepted. Ud6lK.,> L12CLE&& It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 78�-�Q2U FO RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR :i