Loading...
HomeMy WebLinkAbout18-20447 CITY OF ZEPHYRHILLS 5335-8TH STREET ' (813)780-0020 20447 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20447 Issued: 11/13/2018 Address: 6776 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 355,185.45 Total Fees: 14,959.19 Subdivision: SILVERADO Amount Paid: 14,959.19 Date Paid: 11/13/2018 Parcel Number: 05-26-21-0100-01100-0030 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,153 SQ FT APPLICATION FEES BUILDING FEE 1,931.40 ELECTRICAL FEE 409.50 PLUMBING FEE 273.00 MECHANICAL FEE 191.10 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 G Inspections Required FOOTER 2 N D R U H PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB " SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION.- 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER a�u City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ing s" f——/je) Date Received: ib—�D Site: WakW Permit Type: �)� I� 5 Approved w/no comments:❑ Approved w/the below comments: LTV Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) DR Horton Inc-6776 Wagon Trail St-3,153 sq ft Column Es SO. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,820.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,931.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,805.00 TOTAL $ 2,805.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER:1 n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,358.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,959.19 ' I PASCO COUNTY, FLORIDA Permit No. ,,��-- Date Permitted - - Builder Name/Owner Name �C 6;�" Control W. County Parcel No. 0 5-26_2(-V L 0 0- D l CO- 60-50 SubDiv: 5' yer aj 0 Address/Location l2-7-1 Classification/Type of Use c5 f'^L1 L TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. 3 (a 32 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Famlly Detached House Amount $ 7, Qq_ 2$ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt F]Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit. Land Total Recreation Account Recreation Credit 'Recreation Total Zone TOTAL AMOUNT $-7�2 6 Exempt ❑ Yes ❑ No How Determined. LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By D Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of'a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 05-26-21-0100-01100-0030 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive -Tuesday, November 6, 2018 Parcel ID 05-26-21-0100-01100-0030 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $2,644 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6776 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,644 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,644 See Plat for this Subdivision Taxable Value $2,644 SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B PB 77 PG 079 BLOCK 11 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line_ !Use iDescriptionZoning iUnits !Type !Price ,Condition Value jr 1 1 0100 SFR MPUD 6,609.00 SF $0.40 1.00 i $2,644 Additional Land Information FEMA Acres 0.15 'Tax Area 30SI i Code -- Residential Code NEWSUBB Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line ;Description .Year Units !Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page ;Type_ DO R Code,ConditiomAmount 11/2018 19813 / 3320 Warranty Deed 05 ! Vacant !Multi-Parcel Sale 05/2017 19535 / 0546 1 Certificate of Title 05 Vacant ;Multi-Parcel Sale 11/2016 f 9462 / 0384 !Mineral Rights or Royalty Transfer! 05 j Vacant ;Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050100011000030 11/9/2018 D.R. Horton 6776 Wagon Trail St:3,153 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,820.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,936.40 ELECTRICAL: $ 409.50 PLUMBING: $ 273.00 MECHANICAL: $ 191.10 SUB-TOTAL $ 2,810.00 Public Fee 1% TOTAL $ 2,810.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,363.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,964.19 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8"above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required.if M'sir more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete.- 5. Driveways require a R.O.M. use permit. All 4 sides of driveway thrg the sidewalk shall have expansion material. 6. All setbacks shall be met> 7. All property markers shall be uncovered and marked at time of first inspection. �. All A.D.A. requirements shall be met. 9. No electric,plumbing,mechanical,or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C..(Fire Separation). I L Appliances shall'not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the RB.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M130$.1 14. Return air in all bedrooms. F.B.C. Ml620.4 15. Smoke detectors are to be installed in accordance with R313..1 of the F.B.C. 16. All glazing requirements are to be in accordance with R.308A of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board"shall not be us.ed.as a backer.in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in,new construction that uses fossil.-burning heating or appliances or an attached garage: They shall be installed in accordance with the F.&C: 21. All plumbing,mechanical,.and electrical shall be separate from unit to unit; This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23.Tamper:resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 . 24. In accordance with.the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25. Blower door test and blown in insulation curd shall be provided before C.O. 26 A copy ofthe engM eacls shall be with Eerruit at all times 27. Conv of final insulation report shall be 0Mvided with nertuit before.rnaL 28 No fenee,.cool.or screen enclosure is issued with this nermiz RRE.-Finished Floor Elevation F.B.C- Florida Building Code 6th Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) Gity of Zephyrhills Permit Application Fax=813-780-0021 Building Department Date Receivedtr Phone Contact for Permitting -- p Owner's Name k c ,-. .. �`= Owner Phone Number =W31 c1 Owner's Address � ° T,>►"',,v,.J3 5.Owner Phone Number Fee Simple Titleholder Name Owner Phone Number [—--- Fee Simple Titleholder Address JOB ADDRESS Qt ��{��� LOT# SUBDIVISION � 'k=�' c., PARCEL ID# 049d1% " (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN � DEMOLISH INSTALL REPAIR PROPOSED USE F_�9""- SFR Comm OTHER TYPE OF CONSTRUCTION r-L/" BLOCK [� FRAME I J STEEL DESCRIPTION OF WORKko BUILDING SIZE SQ FOOTAGE Z5 �J{ HEIGHT ",t-e"rF-r-c'i'rt�-rnr-r"r's"s"rrst•-r�'�-r"i"t�i"r'i-I-r-r-r`rr'rrr'ir-I-t'-r'-r'r'r�rrs'-r-7'�-r'r"r"a-rr+�-r-t-ma-r'r"r-r-tl- BUILDING $ !St(��� VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $. _• AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING $ 0 q MECHANICAL $ 1( }� VALUATION OF MECHANICAL iNSTALLATION =GAS ROOFING SPECIALTY u OTHER FINISHED FLOOR ELEVATIONS 4w� FLOOD ZONE AREA DYES NO --C-•i-C-L'-�'-�-F-�-•i-�'-C-�-•C-�-a'-�-i-➢-�•-➢-I-:--0--F-C-''-➢�'1--:-+i-9-:-:-f,�➢-I'-C-:-@-7;•➢-8-@`-i-'v-@-;-1-I-a-;-@mu®�@-t--�-@-a--I-R--a- BUILDER , ' i COMPANY - � c .-A-Ci SIGNATURE �` �- REGISTERED I Y/ N FEE CURREN Y f N Address Pic'--]v? /r-<,,.n r ,r'� r" .1c i�� � License# a?C- 03 f-7 0 'ram' :2 .EL.ECTRICIA� a, �,- COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address dJA='Pd ° ' fr2� f' License# . r PLUMBER ^ �`'➢'� .^ m COMPANY P ` 1/ .�f7,� rFra ,9y� .SIGNATURE REGISTERED Y! N FEE CURREN I Y/N Address �„ if} � , , �rl ��.- License# arc.- MECHANICAL COMPANY j"'1,%ral-ei-xi " SIGNATURE f/ � '" -`-'-:--REGISTERED Y// N FEE CURREN Y/N Address � 7 �'"� "� f`+so ar cl rt� 'j' License# t �C+f!7 OTHER -. fj1n�� --- . COMPANY - 1 J�t) i.' fj - SIGNATURE 1 REGISTERED Y/ N FEE CURREN Y/N �! Address �tl t� - i� / License# lliti@IiFittlilii ➢ it1111I11111i111I111II111lIIilllJtlll• 1111@1 ➢ II ! !•I RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wi Siit•Fence installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. *"PROPERTY'SURVEY required for all NEW construction. .-1..4..1�-1--I-➢-S.-�...b-i-i..S-.i--1-�I,-M:i.".-L-�..1-�-J-i-i-4-@•-i.i-E-.P-.i-i-k-tF-.D..B-i..[-@•-N-1•-4-1-4�1-.8..G-�-@-@-�-�-➢-L.-9-i!�&.�--@�I.•I6•••1..,L..�..�. Directions: Fill out application completely. Owner�Contractor sign back of Rippiication,notarized If over$2500,a Notice of Commoncemeht is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs•if shingles - Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROVII . . NOTICE QFDEED RESTRICTIONS: The undersigned understands that this permit may ba subject ho ' " restri `ntiona" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR*RESPONSIBILITIES, |f the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. l�the contractor is not-licensed as required by |avv, both the owner and contractor may be cited for a misdemeanor violation under state |eum. If the owner or intended-contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division--Licons|ng Section at727'847- 8009. Furthermore' if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you,'as the owner sign as th.a oontraotor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance numbar89'O7 and 90-07. as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees,must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or, final power release, the fees rnVnt be paid prior to permit issuance. Furthermore, ifo� PasoCounty Water/Sewer Impactfueaaredua.the/ must bepaid prior to perm|tissuance |n accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, asammeodecU: |f valuation of Work \s $2.5OU.00or more, | certify that |, the app|icant, have been provided with a copy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgrinu|ture.ond Consumer Affairs. If the applicant is someone ' uiharthanthe`uvxner". | pertifythat | hoveobtainedaoopyoftheebovedeschbeddoounnentandpnorn|ee |nOoodfaithto deliver i1to the "ovvner" prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: } certify that all the information in this*application is accurate and that all work will be done in compliance all applicable laws regulating oonotruotion, zoning and land development. Application is � hereby made to obtain a permit to do.work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating cnnetruotion. County and City codes; zoning regulations, and land development regulations, in the jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to,: ' Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive [ands.VVotor/Naetewete[Treo1ment. Southwest Florida Water Management District-Wells, Cypress. Bayhmado` Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' Department of Health & Rehabilitative 8en/ices/Env)nonrnenja} Health UnU-We|}o' Wastewater Treatment,� Septic Tanks. ' UB-Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authohty-Runwsyo. | understand that the following restrictions apply to the use offill: - Use of fill io not allowed in Flood Zone"V~ unless expressly permitted. ' |f the fill material is to be used in Flood Zone "A''. it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting vvhi ch is prepared by a professional engineer licensed by the State of Florida. ' If the fill material is to be used in Flood Zone "/Y' in connection vv|ih a permitted building using stem vvoU construction, I certify that fill w ill be used only to fill the area within the'stem wall. ' If 0| material is to be used in any area, | certify that use of such fill will not adversely affect adjacent . properties. If use of fill ia found toadversely affect adjacent properties, the owner may ba cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan |orequired. |f | annthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. / understand that a separate permit may be. required for electrical wnrk, p|umb}ng, signs, wells, pon|s, air conditioning,* gas, or other installations not specifically included in the application. Apermit issued sha|| be oonoVued to be a license to proceed with-the work and not as authority to v|o|ate, uanoe|, alter' or sei aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors�in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the penn�}ssuspendedor abandoned for 8 period,of six (G) months after the time the Work iscommenced. An extension may be requested. in vvdt|ng' from the Building Official for a period not to exceed ninety (QO) dave' and will demonstrate � justifiable cause for the extension,- If work ceases for ninety (90) consecutive days,the job is on��donadabandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS TQYOUR PROPERTY. IF YOU INTEND TO OBTAIN F\NANCjYJG, CONSULTWITH YOUR LENDER OR AN ATTORNEY BEFORE -14ECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.-117.03) OWNER OR AGENT cnwTnAnTo Subscribed and sw95 to(or—affirmed)before me this Subscribed and sworn to(or affirmed)before me this by umuuvu Who is/are personally known mmeor has/have produced as identification. as identification. ~ Publ ic ' ' Notary uuu Public ` CommissionCommission No, Name of Notary typed,printed or stamped _me of Notary typed,printed or stamped 0 P& Notary Public State of Florida A; My Commission GG 057321 Expires IPJ2112020 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 3, BLOCK 11, SILVERADO RANCH SUBDIVISION PHASES 7, 9B. 11A & 11B NOT YET RECORDED IN PLAT BOOK PAGE(S) OF THE PUBLIC RECORDS- OF PASCO COUNTY, FLORIDA. Curve Table Curve Length Radius Delta Chord Bearing Chord Ci 49.92' 50D.00' 5*43'13" N67'31'21"E 49.90' C2 10C35' 530.00' 11*16*51* S70*18'107W 104.1 a' C3 49.91* 530.00' 5-23'43" S67*21'37*W 49.89' C4 54.44' 530.00' 5*53*D8*I S73*00'02"- —42' PRC V� G4 DE \0� SCALE SCALE C5 0 15 30 PC 1p 4's o ".0 07.1 o 0 ;A ON LOT CALCULATIONS LOT = 6,609 SO. FT. LIVING AREA = 1,104 SQ. FT. GARAGE = 437 ENTRY = ill SQ. FT. LANAI = 0 SO. FT. SON-V jig"'If Qa PATIO = 80 SQ. FT. DRIVEWAY = 396 SQ. FT. A/C PAD = 12 SO. FT. WALKWAY = 29 SO. FT. 2 PI IMPERVIOUS = 33% = 2169 SQ. FT. SOD = 4,440 SO. FT, Q 1A OFF LOT CALCULATIONS RIGHT OF WAY = 898 SQ. FT. i> emu, a . DRIVE APRON = 237 SQ, FT va PUBLIC S/W = 251 SQ. FT. �c� SOD VSQ , . TOTALS 410 SO. FT. r.,r'dil� AREA = 7.507 SQ. FT. pW 0 DRIVEWAY = 633 SO. FT. SIDEWALK = 280 SQ. FT. SOD = 4,850 SQ. FT. PREPARED FOR: 01-HOMIN*HOWE* 103.0 BUILDING SETBACKS FRONT- 20' REAR: 15' SIDE: 5' (50' LOTS) 7.5' (55' & 60' WIDTH LOTS) SIDE STREET: 15' LEGEND: NOTES; BUILDING SETBACK LINE PI POINT OF INTERSECTION 1. ELEVATIONS SHOWN ARE PER LOT GRADING POINT OF CURVATURE CENTERLINE PC PT PONT OF TANGENCY PLANS PROVIDED BY THE CLIENT. RIGHT OF WAY LINE RP RADIUS POINT PRC POINT OF REVERSE CURVATURE DATUM. 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCC PONT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF CONCRETE (C) CALCULATED THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PB PLAT BOOK OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK PGS PAGES LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT so.FT. SQUARE FEET F.E.M.A FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M., FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT THIS IS A PLOT PLAN ONLY POE PRIVATE DRAINAGE EASEMENT FLOOD OTE: PUE PUBLIC UTIUTY EASEMENT I HAVE EXAMINED THE FJ.R.M. MAP No. 12101CO288F. SURVEYOR NOTES: DATED SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY I. THE SURVEYOR HAS NOT ABSTRACTED THE APPEARS TO LIE IN ZONE-X-, AREAS DETERMINED TO BE OUTSIDE THE LAND SHOWN HEREON FOR EASEMENTS, RIGHT 0.2/ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO OF WAY, RESTRICTIONS OF RECORD WHICH GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE MAY AFFECT THE TITLE OR USE OF THE LAND. LOCAL F.E.M.A.AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN.3. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING NW39-45-E,PER PLAT. A5hA ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: A NA E_ FR I SURVEYOR AND MAPPER. SCALE- 1' 30 FEET U FR VE 'Y1 N 0 igitallysigned byh­W Wernan APPROVED BY: j9 APPING I N C. ko-American Surveying&Mapping, CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 a 0% r 18082D LOT 3, __mi1Kjb01PmanPwmcorPorate.w FOR JOB NO. BLOCK 11 3191 MAGUIRE BOULEVARD, SUITE 200 t ORLANDO, FLORIDA 32803 rm c-us- THE [_DRAWN BY., DSS (407) 426-7979 Date20I&09.2209;32.W-"W FIRM I PLOT PLAN 09/20/2018 J WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES.W. BOLEMAN PSM# 6485 DATE INSTR#2018189206 OR BK 9815 PG914 Page 1 of 1 11/0712018 04:00 PM Rcpt:2004641 Rea 10.00 DS:0.00 IT:0.00 TauCa S. OXej�ph.D., Pasco County CC�rk&ComytrotTer Permit No. Parcel ID No 0 5 0 1 CC 00-'-0030 NOTICE OF COMMENCEMENT State of Florida county of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement 1. Description of Property: Parcel Identification No. L-g>-A- i k vg-racW hrj!�LZ-1 street Address: (o-7 '7.Lo Qq ol-I 7rc t k 2. General Description of improvement NewSingle Family Residence 3. Owner Information or Lessee information if the Lessee contracted for the improvement D.R. Horton, Inc Name 12602 Tn1prnm Drivi-m. Tampa 33637 El Address city state Interest in Property: Fee Simple Name of Fee Simple Titleholder. (If different from Owner listed above) Address city State 4. contractor D.R. Horton. Inc Name 12602 Telecom Dive Tampa 33637 FL Address City state Contractors Telephone No.: 5. surety: N/A Name Address city state Amount of Bond: $ N/A Telephone No.: 5. Lender.- N/A Name Address City State Lenders Telephone No.: 7. Per-sons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive Tampa 33637, FL Address City State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates N/A Of to receive a copy of the Llenoes Notice as provided in Section 713.13(1.)(b),Florida Statutes, Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing * f commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Sig;ture MafOw—ne�ro r Lessee, Owner's or Lessee's Authorized OffleerlDirector/Partner/Manager Assistant SecretarVOR Horton, Inc Signatory's Title/Office The foregoing Instrument was acknowledged before me this-1day of K10VUh6eC 20 M_by 1-0 as Assistant Secreta (type of authority,e.g.,off istee,attomey infact)for D.R. Horton. Inc (name of party on behalf of whom instrument was executed). Personally Known D4 OR Produced Identification El Notary Signature 1,1 C,- Type of Identification Produced Name(Print) 01.. AGHTIN QANA ANNE N AGHTIN Notary Public-Stkte of Florida. Commission#GG 010660 wpdatalbes/noficecommencement_pc053048 M)"Comm.Expires Jul 12,2020 P V FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6776 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6776 Wagon Trail St(Lot 3) Jurisdiction: Cond.Floor Area: 2601 Cond.Volume: 23409 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 2281 Single or Multi Point Test Data ELA: 125 HOUSE PRESSURE FLOW: EgLA: 297 1 50 Pa 2281 cfm ACH: 5.85 2 0 Pa 0 cfm SLA: .05 3 0 Pa 0 cfm ACH(50)*: 5.85 4 0 Pa 0 cfm * For prescriptive projects,tested leakage must be 5 0 Pa 0 cfm —7 ACH(50). For performance projects, tested leakage must be — the ACH(50) shown on Form 6 Pa cfm R405-2017 for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing:- 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off,and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes pFKST'tTF or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A -4i:' _,; „ O written report of the results of the test shall be _ Digitally signed by David Burch signed by the third party conducting the test and Date:2019.03.2919:07:47 EDT provided to the code official. CN=David Burch,O=TopBuild fy o Home Services,OU, COD WEK� EMAILADDRESS=David.Burch Signature: @topbuild.com,C=US David Burch BUILDING OFFICIAL: Printed Name: 10 Date: 03/29/2019 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 425262 ASCO PAS C PONST COUNTY `� ✓�„' BUILDING CONSTRUCTION SERVICES 8731 Citizens Drive Date:4/4/2019 COUNTY PLORIDA Suite 230 Ovrr Since.OBPAAT PIACES. New Port Richey,FL 34654 727-847-8126 ** NOT A PERMIT ** Receipt#: 1836496 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1434880 $51.13 $51.13 1836496 3/5/19 Waste Single Family TOTALS: $61.13 $61.13 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1836496 Check 886833 SLEBLANC 13CCCP05W 03/05/2019 $51.13 Total Payments: $51.13 Pavor Address Phone DR Horton,Inc. 1341 Horton Circle Arlington TX 76011 Comments• City of Zephyrhills Solid Waste Address:6776 Wagon Trail Street Parcel:05 26 210100 01100 0030 a o unty u ft Construction Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. - i f i MyReports/reports//PASCOPROD/PASCO/ReceiptAA_V7.rpt 4/4/2019 Page 1 of 1 i • f I I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FO.R BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 'Elev H Express Project Na e, Hayden 2605 Builder Name: DRH Expr Home St Permit Office: JU iA 2�' V City,State,Zip: Zephyrhills,FL, Permit Number 7A Owner: -Ss LA l Jurisdiction: 4 11 , &0 Design Location: FL,Tampa County: {Florida e 2) (Florida Climate ZoN 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sqft.) Insulation Area ri Ext ul Concrete Block-Int Ins , Exterior 2. Single family or multiple family Single-family a. R=4.1 2389.10 Itz b.Frame-Wood;Adjacent R=1 1.0 314.89 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 it 4. Number of Bedrooms 5 d.N/A R= 112 10.Ceiling Types (1541.0 sqft.) Insulation Area 8. Is this a worst case? No a. Under Attic(Vented) R=30.0 1541.00 112 , 6. Conditioned floor area above grade(W) 2605 b.NIA R= ft2 rj N/A Conditioned floor area below grade(W) 0 c.11.Duct R= ft2 s R ft2 7. Windows(252.7 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbi,U=0.34 212.67-ft2 li SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.966 ft. yl Area Weighted Average SHGC: 0.315 14.Hot water systems ii 8. Floor Types (1541.0 sqft.) Insulation Area a. Electric Cap:50 gallons EF:0.950 El a.Slab-On-Grade Edge Insulation R=0.0 1104.00 112 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Total Proposed Modified Loads: 84.98 Glass/Floor Area: 0.097 Total Baseline Loads: 86.22. Pkli* o 1 I hereby certify that the plans and specifications covered by Review of the plans and 14E S )k this calculation are in compliance with the Florida Energy specifications covered by this tFl Code. calculation indicates compliance with the Florida Energy Code. 10 416 PREPARED BY: Before construction is completed r, DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this bui , as designed,is in compliance Florida Statutes. 1; with the Florida Energ C od"") OWNER/AGPNNT BUILDING OFFICIAL- DATE: DATE: NhV 1% - Compliance requires certification by the air handier unit manufacturer that the air handler en/closure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4'11.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming'duct leakage to outdoors, tested in accordance with ANSURESINEVICC 380,is not greater than 0.060 On for whole house. 8431/2018 10:53 AM EnergyGauge@ USA Section R405.'4.1 Compliant Software Page 1 of 5 1 : FORM R405-2017 Florida Department of Business and Professional Regulation Residential Performance Method 11 Project Na Hayden 2605 Elev H , Builder Name: DRH Express Homesj streef:�wa-Q��t�3 r Permit Office: I City,State,Zip: Zephyr ills,FL, Permit Number:' Owner: ?�5L4� Jurisdiction: Design Location: FL,Tampa 1� 'County: (Florida Climate Zo 2) 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 2389.10 ft2 1 b.Frame Wood,Adjacent R=11.0 314.89 it, # ;s 3. Number of units,if multiple family 1 c.N/A R= ft2 ] 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (1541.0 sqft.) Insulation Area 5. Is this a worst case? No a-Under Attic(Vented) 11=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 }' Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 t; 7. Windows(252.7 sgft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 212.67 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbi,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency ii SHGC. SHGC-0 34 a.Central Unit 40.0 SEER:14.00 ` c. U-Factor: N/A ft2 j SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 t SHGC: Area Weighted Average Overhang Depth: 1.966 ft. Area Weighted Average SHGC: a.Electric Cap:50 gallons 0.315 i4.Hot water systems F� 8. FlocrTypes (1541.0 sgft.) Insulation Area EF:0.950 'i a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features i b.Raised Floor R=19.0 " 437.00 ft2 None I c.N/A R- - ft2 15.Credits Pstat l4. Total Proposed Modified Loads: 84.98 Glass/Floor Area: 0.097 PASS Total Baseline Loads: 86.22 4 i C� !hereby certify that the plans and specifications.covered by Review of the plans and �J TJiE 5 s; this calculation are in compliance with the Florida Energy specifications covered by this r Code. calculation indicates compliance with the Florida Energy Code. Y ,; O } PREPARED BY: t�21e-�„ r Before construction is completed s - "'""'•i4 '-'s ' DATE: _ s-al-l� this building will be inspected for 0 .1l' compliance with Section 553.908 Florida Statutes. I hereby certify that this bui as designed,is in compliance 1 with the Florida Energ Co /�. OWNER/AGE T: BUILDING OFFICI�y�Y f DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with,envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with'a-proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSURESNET/ICC 380,'is not greater than 0.060 Qn for whole house. 8/31/2018 10:53 AM EnergyGaugeO USA Section R4.05.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT Sl9mmARY CHECKLIST REPORT n, -PROJECT Title: Hayden 2605 Elev H Bedrooms: 5 Address Type: Lot Information i 'i Building Type: User Conditioned Area: 2605 Lot# 3/11 I' Owner Name: Total Stories: 2 Block/Subdivision. Silverado g j; #of Units: 1 Worst Case: No PlatBook: Phase 7 Builder Name: DRH Express Homes Rotate Angle: 315 Street: j ii Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, I Family Type: Single-family FL, New/Existing: New(From Plans) F Comment: Garage R Face NW i it CLIMATE 5 Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range ({ FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS ?y Number Name Area Volume 1 Blockl . 2605 22630.4 �j - SPACES ii Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 i 1 Yes Yes Yes 2 2nd Floor 1501 13058.7 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet f 1 Slab-On-Grade Edge Insuiatio Main 152.8 ft 0 1104 ft2 _--- 0.2 0 0.8 2 Raised Floor a 2nd Floor ____ 437 fie 19 0.5 0 0.5 u ROOF j Roof Gable Roof Sotar SA Emitt Emitt Deck Pitch \/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 4 1 Hip Composition shingles 1669 ft2 0 ft2 dark 0.92 Na 0.9 No 0 22.6 i� ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1541 ft2 Y N 813112018 10:53 AM EnergyGaugeG USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type I Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood WALLS Adjacent Cavityw ity Width Height Sheathing Framing Solar Belo T� mf�ll Space 1P Ft In Ft In A rps B-XIA111p F:MCtfoj___Abs�Grpri�-/ I N=>NW Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 O_ 0.6 0 - 2 W=>SW Exterior Concrete Block-Int Insul Main 4.1 20 8 .8 173.3 ft2 0 0.6 0 3 S=>SE Exterior Concrete Block-Int Insul Main 4.1 39 8 8 ; 8 343.8 ft2 0 0.6 0 4, E=>NE Exterior Concrete Block-Int Insul Main 4.1- 36 8 8 8 317.8 ft2 0 0.6 0 -5 N=>NW Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 6 W=>SW Garage Frame-,Wood Main 11 16 0 8 8 138.7 ft2 0.23 0.01 0 7 N=>N Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 -8 W=>SW Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 9 S=>SE Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft? 0 0.6 o 10 E=>NE Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 DOORS I => Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In N=>NW Insulated Main None .4 3 6 8 20 ft2 2 N=>NW Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation L=.>: changed,to As Built(rotated 315 degrees). Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGO Imp Area Depth Separation Int Shade Screening I N=>NW I Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 6 ft 2 in Oft 1 in Drapes/blinds None 11 2 N=>NW I Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 6 ft 2 in Oft 1 in Drapes/blinds None 3 S=>SE 3 Vinyl Low-E Double Yes 0.34 0.31 N 46.5 ft2 1 ft 0 in 10 ft 10 in, Drapes/blinds None 4 S=>SE 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 2 ft 0 in -1 ft 4 in Drapes/blinds None 5 N=>NW 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 2 ft 0 in 0ft5in Drapes/blinds None 6 N=>NW 7 Vinyl Low-E Double Yes 0.34 0.31 N 8.7 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 7 N=>NW 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 I ft 0 in 6 ft 10 in Drapes/blinds None 8 S=>SE 9 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 I ft 0 in 0 ft 10 in 'Drapes/blinds None 5 GARAGE 4 Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall.Insulation 8131/2018 10:53 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION is # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 I 1 Wholehouse Proposed ACH(50) .000386 2640.2 144.94 272.59 .363 7 tl HEATING SYSTEM fi # System Type Subtype Efficiency Capacity Block Ducts i; 1 Electric Heat Pump/ None HSPF:8.2 41 kBtu/hr 1 sys#1 it r. COOLING SYSTEM ?' # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts f; 1 Central Unil/ None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM ' # System Type SubType Location EF Cap Use SetPnt Conservation 1 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM f� FSEC Collector Storage Cent # Company Name System Model# Collector Model# Area Volume FEF �? None None ft2 . ii DUCTS ----Supply ---Return--- Air CFM 25 CFM25 HVAC# f -__ () �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool [i 1 Attic 6 261 ft2 2nd Floor 45 ft2 • Proposed On 2nd Floor -cfra 156.3 cfm 0.06 0.60 1 1 TEMPERATURES t` Programable Thermostat:Y Ceiling Fans: Cooling an Feb Mar A r Ma Jun X Ju! Au Se Oct Nov Dec Heating �Xj Jan X Feb Mar Apr I Ma 4 Jun Jui Au Sep Oct Nov �X�Dec Ventin Jan Feb H Mar Apr may l Jun Jul Aug ( Se Oct X Nov Dec 8/31/2018 10:53 AM EnergyGauge@ USA Section R405:4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 .10 11 12 !i Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68* 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Defa,lt(B lb,/,q.ft. 0 ft2 0 ft 0.3 Main Default(8lbs/s 0 ft2 0 ft 0.3 2nd Floor Name: Test Rater Signature: Rating Compant: Test Rater Date: 8/31/2018 10:53 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 5 . ` , 2U17EPL DISPLAY CARD . ^ 8���U �� ����� ENERGY PERFORMANCE LEVEL�(EPK����"=. �� " ==""~ ESTIMATED ENERGY PERFORMANCE INDEX* =* 88 The lower the Energy Performance Index,the more efficient the home' ' ' 1.New home or,addition t_New(From Plans) 12.Ducts,location&insulation level Supply ducts n 6.0 2.Single-family ormultiple-family 2._Shngle-1arn8y b) Return ducts H-__-6.0 o)AHUlocation Attio2ndRoor O. No.ofunits (if multiple-family) 3. 1_- 4. Number ofbedrooms 4. 5 13.Cooling system: Copacity___40.I a)Split system 8EER_-____' 5. Is this o worst case? (yes/no) . 5. JV� b)Single package SEER_�_____ o) Ground/water source SEER/COP______ 8.Condi1ionad floor area(sq.ft.) 5. 2605 d) Room unit/pTAC EEF�______ e)Other 1£.0 7.VVind � m owo, �eandaa�_ a) U-faoUoc(weigh0adavomgo) 7u` 0.373-' b)Solar Heat Gain Coefficient(SHGC) 7b 14. Heating system: Capacity_ 41.0 o) Area 7o� 2���_ Split system heat pump HSPF�_____ b)Single package heat pump HSPF______ _ 8.Gky|ightx c) Electric resistance COP_______ a) U-factoc(wmighiedovanaDa) 8o` NA_ d)Gas furnace,natural gas AFUE______ b)Solar Heat Gain Coefficient(SHG[) Ob` N\_ e)Gas furnace,LPG AFUE_______ f)Othor 820 9.Floor type,insulation level: a) S|ab-on-Qnydo(R'va>uo) 9o` 0.0__ b)Wood,raised(R-va|uo) 9b` 19J0_ 15.Water heating system d Concrete,raised(R-va|ue) 8n. a) Electric resistance' EF0.95 b)Gas fired, natural gas EF______ 10.VVu]|type and insu|aUom, o) Gas fired, LPG EF_______ A. Exterior: d)Sdar system with tank EF_____ 1.Wood frame(Insulation FFva\ua) 1UA1` o) Dedicated heat pump with tank EF�____ l Masonry(insulation FHmiva) 10A2`__£.1 __ f)Heat recoveryuni1 MoatRec%______ B.Adjaoant: g){8hor 1. Wood frame(|nmu|adonR'vo|ue) 10131`_11.0___ 2. Masonry(Insulation R- a|uo) 10132` 16. H VAC credits claimed (Performance Meth od) 11.Ceiling type and insulation level a)Ceiling fans o) Under attic 11o` 30.0 b)Cross ventilation �Nl b) Single assembly' 11b` u)Whole house fan �No o) Knee walls/skylight walls 110 . d) Mu{hzone cooling credit d) Radiant barrier installed 11d� l�� a)K8u�zonehe��ingcx»dK f) Programmable thermostat Yes '*Label required nsquirod by Section R3U31�9 of the Florida Building Code. Energy Conservation,if not DEFAULT.' ' - I certify that this home has compiled with the Florida Building Code, Conservation,through the above energy saving features-which. will installed (or exceeded)in thi_-home before� final- in_ ' anew EPL display card will be complet d based installed code compliant features. � Builder Signature. ` ' � - Add roonofNow Ch�FLZ�: Zephyrhills, FL , ` 8/31/20/810:53x2AN EnorgyGauoe@ USA 6.V.0c'BaReuuV17FoCmhEc�itlon(2u7)oomptianSoftware Page 1orI � Florida Building Code, Energy Conservation, 6th Edition (201.7) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: P Zephyrhills FL, NIANDATORY REQUIREMENTS See individual code sections for full details. V SECTION R401 GENERAL F.] R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of, Sections R402.4.1 through R402.4.5. Exe eption: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelo'Phe building thermal envelope shall comply With Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion andcontraction. R402A.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,b.ackdraft and flue.dampers shall be closed,but not sealed beyond intended infiltration control measures, 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if.installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-bbilt fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. R402.4.3 Fenestration air leakage Windows,skylights and sliding glass doors shall have an air infiltration,rate of no more than 0.3 ctm per square foot(1.5 Uslm2),and swinging doors no more than 0.5 cfm per square foot(2.6 Uslm2),when tested_according to NFRC 400 or AAMA/WDMA/CSA 101/i.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 8/31./201 8 1 o:5.3 AM. EnergyGauge.0 USA FBC 6th Edition(2017) -Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall-be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any wafer lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated1where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R4 02.4.2 and Section R1 006 of the Florida Building Code,Residential. _J R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary el6ctdc-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways L for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. R403.3.2.1 Sealed air handier. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1 Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the manufacturer's air handier enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pal across the entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. DR403.3.5,Bu'ildingeavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55*F(1 3'C)shall be insulated to a minimum of R-3. R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. Ej R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R40-3.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump,The system return pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based onthe identification of a demand for hot water witbin'the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515*1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired Water temperature in the piping in accordance with the times when heated water is used in the occupancy. 813112018 10.53 AM .EnergyGaugd9 USA FBC 6th Edition(2017)Compliant Software Page 2 of 5 . ` ^ ` . . 5AANDATORY REQUKREMENTS ~ (Continued) [� R403.5.5 Heat with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1h inches . . in the hot water distribution line and cold water line located as close as possible m the storage tank. . n4Vo�.6 Water heater efficiencies(wandemry). ' �7 n403s.6.1.1 Automatic controls. Service eate,heatinosystems shall be equipped with automatic temperature controlscapable ov adjustment from the lowest m the highest temperature settings for the intended use.The minimum temperature setting range shall b°from Ioo~Fm140^F(3o^CmVo^C). � ��1.2 Shut down. 8 separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turnedoff.A separate valve shall bo provided to permit the energy supplied m the main bmnm(s)of combustion types of service water-heating systems mueturned off. �7 R400.S.8.uVvme�6�ginomqu|pment vVsm�hoaUnQ°quipmo�installed�inms�or�a|un8o shall memthe minimum�hoiondo*nf �� Table coo4.einCha�er4�the F�hdaeuiNingCode,Enegy{*ma�abuo.Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R4pm.5.o.o.1. �l n4no.�n.�1So�rwam�hoa�ngsy�oms. Solar oyo�msfor domemiohm�me,pmouc�on�en�euby the annual o�arnne�y -- factor of the system,The solar energy factor ofa system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,TestMethods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: ` /. Be installed with d�|ud �haanyeboumoan1odonm,sund4Vdegmowo«thohnrizontm;and e. Be installed aton orientation within 45 degrees u[true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ve ntilation that meets the requirements of the Florida Building Code,Residential,u,Florida Building Code,Mechanical,eu applicable,v,,mmmo,xuppmvo°mnonoo,"anu/mmn including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system in not operating. Fl R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R400.a.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered byan electronically commutated motor. Fl R4uo.s.0 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1 The design air per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. system make-up air shall he provided m conditioned space from attics, orawiupaouv.attached enclosed garages o,outdoor spaces adjacent m swimming pools orspas. ^. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-1 I and theceiling shall be insulated to a minimum of R-19,space pen-nitting,or R-10 mhon,un. n403.7 Heating and cooling equipment(Mandatory). [l R4noz1 Equipment sizing. H�� an d m pmovh�|beo� ac cordance F� equipment loads calculated in accordance with ACnA Manual Jo,other appbvndheating and cooling calculation math000| ise. based on building loads for the directional orientation uf the building.The manufacturer and model number m the outdoor and indoor units(if split system)shall be submitted along with the sensible and total coolingcapacities at the design dih described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.Sy§tem sizing calculations shall not include loads created by local intermittent mechanical ventilation such aa standard kitchen and bathroom exhaust systems.New m replacement heating and cooling equipment shall have amefficiency rating equal mor greater than the minimum required by federal law for the geographic location where the equipment minstalled. IABLER403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY AIRFLOW RATE MAXIMUM' Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/waft Any Bathroom,utility room 90 2.8 cfaifivatt Any_. _ For SI:1cfm~000L/min. a- When tested in accordance with HV Standardmo ' 8/31/2oom�w�W � USA`-FBo0xEu�onpV71 Compliant Software Page 8c*� � ` ' ' ^ 111VIANDATORY REQUIREMENTS ~ (Continued)F� ���1� ��i�equ��� selected ���m� � u not less ��o��u������,��/]uU�y������� lated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's.product lines.The corresponding latent capacityof the oquipalont shall not be less than the calculated latent load. The published value for AHR|total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall bo used m select cooling-only equipment.This selection,haU.b based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relat ivo humidity uned)o,the load calculation and shall bo adjusted for return side gains if the return duc|(s)ia installed inon unconditioned space. Exceptions: I. Attached single-and multiple-family residential equipment sizing may be selected xo that its cooling capacity is less than the oalcblamdtotal sensible load but not less than 8o percent vf that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R*oo.r1.2 Heating equipment capacity. �l n403.7'1.2.1 Heat pumps. Hem pump sizingshall uo based nn the cooling requirements mv calculated according mSection R4oa.r.1.1.and the hauu pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is1.15 times greater than the design cooling load. [� R403z122Elentric resistance furnaces. Electric resistance furnaces shall bv sized within 4Kwof the design requirements calculated according m the procedure selected in Section R400I1. � R403��3.Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7,1. ' �� R4ou.� �Ex tra required special occasions. Rex�anooem � qvnOexcess upomgorhoaVngnqu�namoapon8ynnao �� intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system isutilized to provide cooling`or heating to the major entertainment areas. e. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units serving multiple dwelling units shall comply with Sections /—� oovo and u*u4m the/E^C—Cvmmeroa Provisions m lieu m Section R+vu. R403. Snow melt and ice controls(Mandatory) Snow-and building,ice-melting systems,supplied t'hrough energy service to the shall include m� � *h the pavement temperature is above SO»F(I 1C) and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 401F(4.8*C). �l n4Va1Vpuo�and permanent spa ona�yopnsumphon�and�on4. The on�OyuvnuumpUpno(pools�dpermanent o�s �� shall bein accordance with Sections Fwo31V.1 through R4np.1o.5. �l R4Uo1u1Heaters. The electric power to heaters shall bo controlled bya readily accessible hn-o*switch that is an �-� integral part of the heater mounted on the exterior of the heater,vr external tu and within feet 4mn4of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. Fl n4oa.1�o Time switches. Time nwi�hnxm�ho,xon�o\m�hodxth�can a�umatioo|�mmoff and onoum�dingmepnmatschedule �� shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: t Where public health standards require 24-h pump operation. 2. Pumps that operate solar-and pool heating 3. Where pumps are powered exclusively from on-site renewable generation. ' �l '~~ uxCovom. ~~~~~ heatedmwinmin0ponbondoutdvn permanent spas shall be equipped with a`~p~'`�~~~^cover on mg the water surface ova liquid cover or other means proven to reduce heat loss, Exception: Where more than 7o percent of the energy for heating,computed over an operation*season,is from site-recovered energy,such ou from o heat pump nr��a,eno�y000mo^ovwemoro�o vapo�m��am means uoaonot h�mqu|�d. ` n4on.1�4Ge�and ui���dpool and spa xe�e�, /U/�s-and�|�vedpp�and spa hoa�mand|h�numinimumd`anna| efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural orLP gas shall not have continuously burning pilot lights. ' 8/311201810:53Am Eno0yGuugs@USA FBCmb Edition(2017) Compliant Snhram page^of5 ` R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandator0he energy consumption of electric-powered portable spas shall be controlled by the requirements of A PS P-14. SECTION R404 .ELECTRICAL POWER AND LIGHTING SYSTEMS E] R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed.fighting fixtures shall be high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. 8/311/29 18 10:53 AM EnergyGauge@)USA FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev H Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Jurisdiction: z Design Location: FL,Tampa C) COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit Ceiling/attic the insulation and any gaps in the air barrier shall be sealed, shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within.corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of . Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms'to available space shall m(tend behind pininn and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed.. HVAC register boots HVAC register boots,that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids etwon a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400. 8/31/2018 10:53 AM EnergyGauge@ USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: Doti Informs#ton` `•" Builder: DRH Express Homes Community: Lot: 3/11 Address: City: Zephyrhiils State: FL Zip: Te§tfleslrl��S Passing'results:rzaust me'ete`ilher the Performance Preserrptrve;`,or ERl llrlethod: :.;... .: Vt.,. Y f no gv.;,, .: d i;;.;. i PRESGRIP.TIUEMETIit)[3=TFi"e'.buildin or,;dweNlii uriifs}iaiit�e`tested:"and-verifieda"sjha n an'_air;leakage�rate_o,notexceedng"jar .changes per hour at.a pressure of(l:2 inch w:g (50 Pascals)in Clmiata Zones Land 2 . ;.FERFORNIANCE_or ER METHOD-Tile"6ui{'ding or dwelling unit'shal1 be tested and verified as having an airtieakage rate of riot exceeiiing: the selected QCH(50)value,as shown on Farm R405 20i7(P,erformarrce)!�or Fi406 2017(ERl) section labeled-as infiltratiari,sub=se"ction ACN50: ACH(5t7)specified grrForrp F7405 2017 Energy Calo(Performanc"e)or F14t)6 20.i7`(ERI) 7.000 x 60 22630 — Method for calculating building volume: CFM(50) Building Volume ACH(50) Retrieved from architectural plans F-1 PASS �Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing:. 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and.sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. .T n Y 4 - M ; Company Name: Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 8131/201 8 1 0s53:31 AM EnergyGau9e®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software •Page 1 of 1 Duct Leakage Test Report Residential Prescriptive, Performance or ER1 Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: �0�1�IIfOYttkott6n, W a 9 f Builder: DRH Express Homes community: Lot: .3/11 Address: City: Zephyrhills State: FL Zip:' n r�uctakge Test F€'esu4s. Pre scr�pt;!ve`Wfhod o �II�Ri'��fh�d C> ' Per' rr�in� c. Y> System 1 cfm25 --,—.� PreScli•Iptve{�@hl?d ;cfm25 Ta ( tal} System 2 cfm25 To.qualify asu substantially leak free"Qn Tkotal must be(ess than ar >equa{�to 0 04 if air handler unit yswin"stalled if a'ir liatidl',er unit is nat ;�' u.� , System 3 cfm25 install ci, ust:be less;th n r equa kT e QnTota!ni a o lxto Q g3 -This`'testing method rn'eets tfe requir'ementstimaccordance w�th, ection R403 3 3 Sum of any cfm25 !s,the err handler uilttiiristalleca'durrng fet�ng7 YES( a�- -❑N©°( q°nj Total of all cfm25 f (� Phi`fotiCWild IERI'M61-had,{�cfm25{t�utorTota!} ro=qualtfy using this method,4Qn must clot be greater than the r 2605 On proposed dtcct pp ;,AgeyQn specified on- TotalForm R40 241Z of R406 2C117 of all Total Conditioned systems Square Footage Leakge,Type selected on Form tF Qn specified an FormrR4(15 211:f'7= R4Q5 2t?17(Eirerg-yGa%) r..R406 201ar R4506 20 f 7 PASS HAIL =: ` `4x Proposed on = 0.06 «. Duct tightness shall be verified by testing in accordance with ANSURESNETACC380 by either individuals as defined in Section 553.993(5)or(7),.Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f), (g)or(i),Florida Statutes. a•-• Eia z:4'a "M. , o-T r rs Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the, selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#:, issuing Authority: 8/31/201 8 1 0:53:37 AM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Pagel of'1 - wrightsa ft" Manual S Compliance Report Jo Entire Mouse By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 ?;'?E° .• 'ir`sss. :^ y�;a+t+,v�.�,g e g•_,:a4; :'ir,", i y?d-}e'< .�?£' .�wh04 ':-2d,: ,K:.,,s. For: ,-, DR Horton Lot 3 Blk 11 Silverado, Zephyrhills, FL x,=: ,:�t"",.s� �'��,ta'z..�s�a.•:'�; .�, '.• c`�.,-.;„ ..ems �.p- ® ,© ^ .„::~%<?': , >G ,,,, ,,..'k$-sr.,,C,rt's.5.,£, „-�?'....g�a, 'b;.t'' �,{s,'#;�'s .< kx.r,-•e���..-a yro; ,as-*.:'-F,.�u 7,�T:�'Y"'�''"��.s Design Conditions Outdoor design DB: 91.2°F Sensible gain: 30013 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1°F Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 34157 Btuh Indoor RH: 50 Estimated airflow: 1367 .cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier, Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 108%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 38714 Btuh 113%of load SHR: 84% 'g�;'sv. �� °a:,r;�•�-fa`�`'µ�`= ,: �x, �>'> � 0 F $ 9 ,�,'= t 9:. r�`sa :a...s,»as",..-. �;,^ ✓��;,. .b'N,!.-,,SL'. ..rc.' M&_ � �„ _" :{r;ic,�,...,;':.�' `^�,.._ 4'.;✓;�...a�..W.,,'.,., HN�.:a'h�' Design Conditions Outdoor design DB: 40.0°F Heat loss: 28704 Btuh Entering coil DB: 69.5°F Indoor design DB: 70-0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm , Output capacity: 37299 Btuh 130%of load Capacity balance: 33 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 102% of load. Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. ti �.i i71E$O 2018•Aug-31 10:54:31 'A=ACC "( .. g Right-Suite@ Universal 2017 17A.21 RSU25554..press homesiHayden 4EHS 2605-2 N nd tl block,rup, Cale=MJ8 House Front faces:NW Page 1 Lewd Short Form Date ��Il�h����'� Date: EhOre House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 {,mA7..�^,{.s: co;y:.5°.-+.R' SA;k:?„x•,- .:�. --; : ;,.:.mac,;. ..y', k. ,fi,y.:<.'-:r :fy;::.. ,.:r,-ers;<.;,a.y.;w�p.,:.;:'•zgr,. ...-"r;...s^.s^`i%? - =:z>>.�raaer_;°. ..�d,"t:.�..��'f'tt`^ ace` � k:..- ,;::°r,,,','- ";;: m .� '«�.S?'a. =:*t{''r.° .,w.�r;, _.,�'=•;,;:,, .n•;.,;4 For: DR Horton Lot 3 Bik 11 Silverado, Zephyrhills, FL $`�€:.'.;:a' 'R-",`�.,:g.,S.L'<::t,7z` r-.fM ;.•ir 't ':5,- , 5. .'c' .Yars N f s:z' �;s„"'T„2. % �,x,.r. =a','�-'i#�"n�'�'i' .e- =�u' ..»?,�`I. �. �,''ve�,... � 4 t! N� "@, �e. , '-.F� ��;..ri�,. �k , ., da;-,;,a. a; ' :�? .�ff•�,'"rts;. ��� �1�,<.. :�eS'r=:� ��.„,,.a�tl.•�•.``� '.F�• w ,�t° <«�;: fi ;,�g:. �5�. ';�•.^:gy.:;+� . .:iq,;F.:;�;;�:.°�'•.;�ry 's��_::wrms,� ,sz.ps;,"°.. �"�..r Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db (°F) 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces .0 . Daily range - L Inside humidity (°l°) 50 50 Moisture difference (gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency ' 11.3 EER, 13.7 SEER Heating input Sensible coaling 30750 Btuh Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh Temperature rise . 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=33 OF Backup: Input=9 kW Output=29290 Btuh 100 AFLIE ROOM NAME Area Htg load CIg load Htg AV Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7235 7882 345 359 bed 2 164 2906. 1816 138 83 powder 59 950 382 45 17 flex 156 3048 2737 145 125 foyer 75 1416 963 67 44 stairs 44 0 0 0 0 bed4 181 1973 2133 94 97 bed3 184 2272 2922 108 133 wic 60 141 ' 184 7 8. wic 2 32 .849 804 40 37 m suite 277 2889 3659 138 167 bath 135 391 370 19 17 upstairs living 234 1451 2535 69 115 stairs 2 50 0 0 0 0 . Calculations approved by ACCA to meet ail.requirements of Manual J 8th Ed. +ap.� F4sof�° - 20i8-Aug-31 10:54:31 - �.� Right-Suited Universal 2017 17,0.21 RSU25554 Page 1 Cii ...press homeslHayden 4EHB 2605-2nd fl biock.rup Cale=MA House Front faces:NW bed5 175 1925 2088 92 95 laundry 41 468 955 22 44 a/c 19 0 0 0 0 bath 3 96 791 583 38 27 . hall 63 0 0 0 0 Entire House d 2651 28704 30013 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 30013 Latent cooling 4144 .TOTALS 2651 28704 34157 1367 1367 Calculations approved by ACCA to meet all.requirements of Manual J 8th Ed- wry h$SUtt" 2018-Aug-31 10:64:31 Right-Suiteb Universal 201717.0.21 FISU25554 page 2 +CA...press homes\Haydeh 4EH6 2605-2nd It block,rup Calc-=MJ8 House Front faces:NW Wrig,htso t Project Summary Da e: Entire House By: Progressive Air Systems, inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 xy'.,Sv.'".:v7';1+9;:^ ;-Y,.,f 'A:3?'"**9,-�.rr['-0�,-,<;ar; :+`^.aJk> `r'�v�ro`:..�,.�'.a^h>��-i':s zear�% Ft 9 � .,k'.:,.y, ,<;k P;"'�§eu.,, ;.' :,tt:.< r: :.� �=.•' ,✓,�„` .�a;� •^g ..,� ass.': �tb'k ���.:y_a. t s''"a. �.'�=r'i�'�- ,.aa�+'�>'�'t�` 'M;':`-'z�'K=€.�f� i For: DR Horton Lot'3 Blk 11 Silverado, Zephyrhills, FL Notes: N". "�k,�'✓ h:$.L Y. ,, " +�` =�,:d".tJi'��N�,.YS`a^G+i' ' _ - � ....w. Y Weather: ' Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF - Outside db 91 OF Inside db 70, OF Inside db 75 OF Design TD 30 OF, Design TD 16 OF Daily range L. Relative humidity 50 % Moisture difference 54 grllb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22114 Btuh Structure 21050 Btuh Ducts 6590 Btuh Ducts 7 8963 Btuh. Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load. 28704 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration. Equipment sensible load 30013 Btuh Method Simplified Construction quality Semi-tight Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent(0 cfm) 0 Btuh Heating coolin (none) Area(ft2) 2659 26N Equipment latent load 4144 Btuh Volume(W) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 34157 Btuh Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR_ 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier- Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref' -- Coil FB4CNP042 AHRI ref Efficiency _ 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling - 30750 Btuh Heating output 38500 Btuh @ 47OF Latent cooling 10250. Btuh Temperature rise 26 OF Total coaling 4i000. Btuh Actual airflow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.56, in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 . Capacity balance point=33 OF Backup: Input=9 kW, Output=25290 Btuh, 100 AFUE Calculations approved by ACCA to meet ail requirements of Manual J 8th Ed. ' Wt ii�llif80 .Y,--- Right-Suite�el'Universal 201 2018-Aug-31 10:54:31 717.0.21 RSU25554 CCP. m...press hoes\Hayden 4EHB 2605-2nd fi_biock.rup, Catc=MJS House Front faces:NW Page 1 ' FORIU1 R405-2017 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTA77ON CHECKLIST Florida Department of Business and Professional Regulation .Simulated Performance Alternative (Performance)Method Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page)and an input summary_ checklist that can be used for field verification (usually four pages/may be greater). ❑ Energy Performance Level(EPL) Display Card*(one page) ❑ HVAC system sizing and selection based on ACCA.Manual S or per exceptions provided in.Section R403.7 ❑ Mandatory Requirements (five pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 8/31/2018 10:32:18 AM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of i