Loading...
HomeMy WebLinkAbout18-20457 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20457 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20457 Address: 5554 11TH ST Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est.Value: Parcel Number: 11-26-21-0010-1'0400-0150 Improv. Cost: 6,092.01 OWNER INFORMATION Date Issued: 11/26/2018 Name: BROWN, VICTORIA Total Fees: 112.50 Address: 5554 11 TH ST Amount Paid: 112.50 ZEPHYRHILLS, FL. 33542 Date Paid: 11/26/2018 Phone: 813-614-1247 Work Desc: REPLACE 12 WINDOWS S/S CONTRACTORS APPLICATION FEES POWER HOME REMODELING GROUP LLC BUILDING FEE 112.50 I I Ins actions Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 6DNtRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 1'LU HIUH City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: k, Date Received:Site: Permit Type: (�������C�,S/e� Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ r a i This comment sheet shall be kept with the permit and/or plans. Nov 0 'a tole Kalvin Swj'�� —Plans Examiner Date Co ctor and/or Homeowner / (Required when comments are present) Plan Review Windows & Doors 1) Need manufacturing installation specifications: 2) Must meet sections R308 and R612 of the 2017 F.B.C. 3) If windows are to be installed inside the historical district,.they will need to be approved .by the historical committee. 4) No other work shall be permitted (framing, plumbing, and mechanical) unless otherwise specified.: 5) This is for replacement (glass for glass) only. If you wish to change from screen or vinyl windows to glass,then additional information is required. 6) All windows to wall connections shall be left visible for. inspection. 7) All labeling and stickers shall remain on windows until final inspection. 8) No work shall start without permit first. 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received phone Contact for Permitting L:8=13334 9718 -�T Owner's Name Stephen and Victoria Brown Owner Phone Number (813) 614-1247 Owner's Address Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5554 11 th Street Zephyrhills, FL 33542 LOT# SUBDIVISION PARCEL ID# 11-26-21-0010-10400-0150 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR E ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR COMM = OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Remove and replace 12 windows - size for size BUILDING SIZE I I SQ FOOTAGE= HEIGHT ®BUILDING $ a 6,092.01 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address I License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address \ License# OTHER t�.L1 COMPANY Dan Price - Power Home Remodeling SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4135 Crescent Park Dr Riverview 33578 License# CRC1331654 III I I I I I I I I I III I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ` ^ NOTICE OFDEED RESTRICTIONS: The undersigned understands that this permit may bosubject which may ba more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired o contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations, If the contractor is not licensed as required by |ew, both the owner and contractor may be cited for misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Fudhennona, if the owner has hired o contractor orcontractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the nnntractor, that may been indication that he is not properly licensed and is not entitled hopermitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction cf new buildings, change of use in existing bui/dinga, or expansion of existing bui|dingo, as specified in Pasco County Ordinance number 8S-O7and SO-U7. aoamended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power na}eaoa. If the project does not involve a certificate of occupancy or final power release, the fees must bepaid prior to permiti Furthermore, if Pasco County Wat r/G Impact Protectionfees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that 1, the applicant, have been provided with,a copy of the "Florida Construction Lien Law—Homeowner's .=".de" prepared by the Florida uepu/u/'e'u of ASncwnu": and Consumer*Affairs. none applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the^ovvner" prior tocommencement. CC}NTRACTORVOWNERL`SAFFUDA\DT: | certify that all the information in this application io accurate and that all work will be done in compliance with all applicable laws regulating conotruction, zoning and land development. Application is hereby made to obtain o permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |owa regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | a/ao certify that | understand that the regulations of other government agencies may apply to the intended worh, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Bmyhemdo, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida VVaher. Management District-Wells, Cypress Boyheodo, VVmdmnd Anesm, Altering Watercourses. ' Army Corps cfEngineens-SeawaUo. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unih4NmUm, Wastewater Treatment, Septic Tanks. ' U8 Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authority-Runways. | understand that the following restrictions apply to the use offill: ' Use of fill in not allowed in Flood Zone"\y' unless expressly po,mibad. - If the fill material is to be used in Flood Zone ^A". it is understood that o drainage plan addressing a ,.compensating volume" will be submitted at time of permitting which is prepared by professional engineer licensed by the State nfFlorida. - If the. fill material is to be used in Flood Zone "/Y' in connection with a permitted building using stem vva|| construction, I certify that fill will be used only to fill the area within the stem wall. - If fill motaho| is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to odmenao|y affect adjacent propadiem, the owner may be cited for violating the conditions of the building pannd issued under the attached permit application, for lots |aoa than one (1) ' acre which are elevated by fill, on engineered drainage plan iarequired. |f| om the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that a separate permit may be requiredfora|ecthca| wmrk. p|umbing, signo, weUo, poo|u, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions cf the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension / may be nsqueatad, in writing, from the Building Official for o period not to exceed ninety (SU) days andwiU demonstrate \ justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR ' PAYING TWICE FOR IMPROVEMENTS TC]YOUR PROPERTY. |P YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR -' -CONTRACTOR Subscribed and sworn m(or affirmed)before methis Subscribed and swom o is/are personally known to me or has/have produced Who is/are personallyThown to m66r has/have produce'd as identification. as identification. by by Al�[� 4rh6azel-I Notary Pvwo Notary Public Commission No. com iVn No 813-780-0020 City of Zephyrhilis Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting F( 813 1 334 9718 . . . . . . . . . . . . . . . . . . . . . . . . n Owner Phone Number lI a=(813)61.4-10 247 F . Owner's Name Stephen and Victoria Brow n Owner's Address &X44 fit Owner Phone Number Fee Simple Titleholder Name i Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5554 11 th Street Zephyrhills,FL 33542 LOT# SUBDIVISION PARCEL to# )10-10400-0150 . (OBTAINED FROM,PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR 8ADDIALT SIGN DEMOLISH R INSTALL REPAIR PROPOSED USE = SFR = COMM OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME STEEL = L DESCRIPTION OF WORKRemove I replace 12 windows-size for size BUILDING SIZE So FOOTAGE HEIGHT ®BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE = PROGRESS ENE W.R.E.C. =PLUMBING 1$ =MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATIO =GAS = ROOFING E] SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO . . . . . . . . . . . . . . . . . . II . . . . . . BUILDER COMPANY SIGNATURE I REGISTERED I Y/ N FEE CURREN YIN Address I License# ELECTRICIAN COMPANY [_ SIGNATURE REGISTERED Y1 N FEE CURREN Y/N Address I License# PLUMBER COMPANY = SIGNATURE REGISTERED Y/ N FEE CURREN LILN J Address I License# F_ MECHANICAL COMPANY SIGNATURE l REGISTERED Y1 N FEE CVRREN Ly IN Address License# OTHER COMPANY Dan=Price-Power Home Remodeling SIGNATURE REGISTERED I Y/ N FEE CURREN Address 4135 Crescent Park Dr Riverview 33578 License# FCRC1331654 i 7 I111111 11111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wt Silt Fence Installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivislonsilarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite.Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Directions:' Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ***Please mail Certified Copy to contractor's address*** NOTICE. OF COMMENCEMENT 2018174704 Permit Number Tax Folio# 00 0- I&YI X)- The undersigned hereby gives notice that improvement will be made to O �1997990 Recc: 10 00 certain Real Property,and in accordance with Chapter 713, Florida Rcpt- IT: 0.00 Statutes,the following information is provided in this Notice of Commencement. DS; 0.00 Clerk 10/15/2018 K. D. K. , DptY 1. DESCRIPTION OF PROPERTY: (Legal description.of the noperty and street d Iress,if available.15E Ph-D.PASCO CLERK & COMPTROLLER PAULA s,OINEIL, 125 L9 - I of I lei/15/201 01:40 im, (A OR BK 339%3 2. GENERAL DESCRIPTION OF IMPROVEMENT:— Remove and replace cl- -s"�- ter S< This space reserved for recording 3. OWNER INFORMATION OR LESSEE INFORMATION IF THE LES7E CONTRACTED FOR THE IMPROVEMENT: Name&-Address: V MprA AM-;-q-51 I I" L Z 3 5!12 Interest in Property: Remove and replace Fee Simple Title Holder(if different from owner listed above): 4. CONTRACTOR: Name: Dan Price- Power Home Remodeling Phone Number: 610-874-5000 x4037 Contractors Address: 4135 Crescent Park Dr Riverview FL 33578 6. SURETY(if applicable,a copy of the payment bond is attached): Amount of bond: $ Name: Phone Number: Address: 6. LENDER'S NAME: Phone Number: Lender's address:,, 7. Person's within'the.State of Florida Designated by Ownerupon whom notice or other documents may be served as p(cvld6d by Section 7113.13(1)(a)7., Florida Statutes. Name: Phone Number: Address: 8. In addition, Owner:designates of to receive a copy of the Lienor's Notice as provided in Section 713.5(_1)(b), Florida Statutes. Phone number of person or entity designated by Owner: 9. Expiration of notice commencement(the expiration date will be I year from date of recording unless a different date is specified. 20, WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF Comm ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDAES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPEC U11,.4' 0EN] N_ IN M 0 "5 EN E M -XI �Tv. WM T _E,?OFi,`CO t, G EN (Signatuf6 oTowner or Lessee.or Owner's or Lessee's (Print Name and Provide Signatory's Title/Office) Authorized Officer/Director/Partner/Manager) State of Florida County of Township: The for li_g instrument was acknowledged before me jhissll day of 20L�_SL_ by , Instr for (type of authority,...e.g.officer:trusteii,att§rney iryfact) �(name of party.on If of h trument was executed) w 9AJ 5P Personally Known or,Pro.aj* Z-14-1 Nd0d Sop (signature of is-State of Florida)' b0M.XMisiber 8,2021 GG11991S Nat55t+kffli7_ . Prepared by: Michael George 4"N".. ROW MM As=ft" STATE OF FLORIDA COVAITYOF PASCO _. THIS IS TO CERTIFY THAT THE FOREGOING IS A -^' � • A TRUE%4ND CORRECT ON FILE OR COPY OF THE DOCUMENT q ;PA' ALAS-n OF PUBLIC RECORD IN THIS FFICE In god-we Trust HAND ANQ OF LCI'A'SEALTHIS DAY OF !�i . 'NEIL,CLERK&COMPTROLLER ----- DEPUTY CLERK lvanonal 17eaaquarters OWPI C11 d11U VILAU11d DIUM 2501 Seaport Drive,Chester, PA 19013 33-42878 888-736-6335 September 25, 2018 p ®' WWW.POWERHRG.COM su� CRC1331654 „oar— PRODUCT SPECIFICATIONS naooau a: Buyer(s)'Information and Description of the Property: Project Number: 33-42878 September 25,2018 Stephen Brown Date of Agreement (813)614-1247(Stephen's Cell) Victoria Brown 5554 11 th Street Zephyrhills, FL,33542 County: Pasco Township: Buyer(s) listed above hereby jointly and severally agrees to purchase the goods and/or services listed on the accompanying specification sheets, in accordance with the prices and terms described in the Custom Remodeling and Improvement and the Product Specifications (collectively,this"Agreement"). Pre Installation Inspection Date: Your pre installation inspection is tentatively scheduled for TBD. Windows-WinForce Duraglass Inclusions:All windows meet Florida State product approval.This includes reinforcement, nighttime safety locks(on Double Hung windows only), double locks (on Double Hung and Slider windows only), welded corners, Heatshield 70, Duraglass, installation, clean up and haul away of all job-related debris. It is agreed and understood by and between the parties that the Product Specifications, along with the Custom Remodeling and Improvement Agreement, constitutes the entire understanding between the parties, and replace any and all prior negotiations, representations, or agreements, either written or oral. The Product Specifications may not be changed, modified, or varied in any way unless such changes are in writing and signed by both Buyer(s) and Contractor. Buyer(s) hereby acknowledge that Buyer(s) has read the Product Specifications. I have read and received each page of this 2 page agreement. Power Home Remodeling Group Buyer(s) Buyer(s) /09/25/18 o /09/25/18 Signature of Remodeling Consultant Signature Signature Matthew Holowiak Stephen Brown Victoria Brown YOU,THE BUYER(S), MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION.SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. September 25, 201819:39 11111111111111111 IIH 111111111111111111111111111111111 IN11111 rvavonai rleaaquar-Eers OLUP11VII d1lu vlutulla DIUW11 2501 Seaport Drive,Chester, PA 19013 33-42878 888-736-6335 September 25, 2018 WWW.POWERHRG.COM CRC1331654 Project Specifications Windows: Front 1 73.0"x49.5" WINDOWS: Models WinForce Duraglass Styles Slider Types 2-Lite Configs None OPTIONS: Color White/White: Grid Pattern : None/Removal Block/Additional Details None FrT n JAL- Windows: Front 1 73.0"x49.5" WINDOWS: Models WinForce Duraglass Styles Slider Types 2-1-Ite Configs None OPTIONS: ColdrWhite White Grid Pattern : None I Removal Block I Additional Details None Windows: Front 1 73.0"x49.5" WINDOWS: Models WinForce Duraglass Styles Slider Types 2-Lite Configs None OPTIONS: Color White White Grid Pattern: None 1 Removal Block l Additional Details None Windows: Front small 1 36.0"x49.5" WINDOWS: Models WinForce Duraglass Styles Double Hung Types None Configs None OPTIONS: Color White/White: Grid Pattern : None I Removal Block I Additional Details None ,-U:i September 25, 2018 19:39 11111 HE IIIIIIIIII IN IIE E12 W34 UGR=2711 BAS=816 w 924 324 N 24 12 %NIB E34 FOP=72 i�Ow 84 N4 E18 This is a acceptable Site plan submittal, to be included with the product approval cover sheet for windows; and can be obtained from the Pasco County Property Appraiser web site • 1/16/2018 Florida Building Code Online ait, 1 BCIS Home Log In User Registration Hot Topics I Submit Surcharge ? Stats&Facts Publications FBC Staff BCIS Site Map ? Links ,Search b a 00',zlir,11, Product Approval USER:Public User Product Approval Menu>Product or Application Search>Application List>Application Detail FL# FL22300-R1 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ALL WORK SHALL Product Manufacturer Northeast Building Product�in�ES FLORICq �O�FLY WITH PREVAILING Address/Phone/Email 4280 Aramingo Ave 1VATICNAL ELECTBUI Coj)E,CO®E, Phi(2115)51phia,PA 35-7110 19124 CAND THE CITY OF�IECP�YjILLS L.Knowles@nbpmail.com R®INANCES Authorized Signature Lucas Turner Luke@TurnerEC.com Technical Representative Address/Phone/Email 7 . Quality Assurance Representative [U�E Address/Phone/Email Cl7-y OF 7�� `. NOVt! o p 9®18 Category Windows ��f4'S'+e{1�n. R4 A�r�R��L� G Subcategory Double Hung �9i1 ��V�y4 Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Scott Wolters,PE '3 Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2011 ASTM E 1886 2005 ASTM E 1996 2009 TAS 201/202/203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 12/28/2017 Date Validated O1/07/2018 https://www,floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%a2fK8XPIxi6lKfLNaUwjFbYC3vEIF7geadJ3C6vg%3d%3d 1/2 1/1 6120 1 8 Florida Building Code Online Date Pending FBC Approval Date Approved 01/10/2018 Summary of Products i FL# Model,Number or Name Description .........._...__..__...__....._.........................._..._._..........................._..-____-_.._.._..._...................._.........................._..-_........._ .__...._.._.........._.... ..._...._._........._.___............__...._.... __...._....... 122300.1 WinForce Double Hung Impact WinForce PVC Double Hung Window,Large Missile Impact Limits of Use Certification Agency Certificate E Approved for use in HVHZ:Yes FL22300 Rl C CAC 86-157CAR odf { Approved for use outside HVHZ:Yes Fly R1 C. CAC 86-164C.AR odfDdf I Impact Resistant:Yes FL22300 RI C CAC 86-204CAR.odf Design Pressure:N/A FL22300 R1 C CAC 86-211CAR.odf Other:Please see Certifications,Installation Instructions,and FI.22300 Rl C CAC 86-214 .AR odf Evaluation Report for additional information,design pressures, F 2 300 R1 C CAC86- 15 AR ndf and configurations that are approved for the HVHZ. FL22300 R1 C CAC86- 6 AR odf FL22300 RI C CAC 86-403CAR odf I. FL22300 R1 C CAC 86-412CAR.12df FL22300 R1 C CAC 86-413 AR-orif FL22300 RI C CAC86-414 AR.odf FL22300 Rl C CAC86-415 AR•odf f F 300 RI C CAC_86-419CAR.12df FL22300 R1 C CAC86-4 4 AR.odf Quality Assurance Contract Expiration Date 02/16/2021 Installation InstrFPuctions FL22300 Rl II A-WinForce-DH-LM-A odf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Evaluation Reports FL22300 RI AE EvaIR-Dort-WinForce-DH-LM-A.odf Created by Independent Third Party:Yes 22300.2 WinForce Double Hung Non-Impact WinForce PVC Double Hung Window,Non-Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes F 7 00 Rl C CAC86-156 AR.odf Approved for use outside HVHZ:Yes FL22300 Rl C CAC 86-169CAR.12df Impact Resistant:No FL22300 RI C CAC86-404 AR.odf Design Pressure:N/A FL22300 RI C CAC 86-40 .AR.odf Other:Please see Certifications,Installation Instructions,and FI.7 00 R1 C CAC 86-410 .AR.Ddf Evaluation Report for additional information,design pressures, FL22300 R1 C CAC 86-411CAR.odf and configurations that are approved for the HVHZ. FL22300 Rl C CAC 86-417CAR.odf FL22300 R1 C CAC 86-421 AR odf FL22300 RI C CAC 86-422CAR.pdf Quality Assurance Contract Expiration Date 02/16/2021 Installation Instructions FL22300 Rl ri FPA-WinForce-DH-NI-A.odf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Evaluation Reports FL22300 R1 AE EvalReport-WinForce-DH-NI-A.odf Created bx Inde endent Third Party:Yes 4;acI< rifuxt Contact Us;:7601 Blair Slone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.:;Privacy Statement::Accessibility Statement;:Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395. `Pursuant to Section 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S., please click heM. Product Approval Accepts: Credit Card Safer https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs3M6m9%2fK8XPIxi6IKILNaUwjFbYC3vEIF7geadJ3C6vg%g3d%3d 2/2 GENERALNOTES 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK FL#22300 WINFORCE DOUBLE HUNG WINDOW EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMA/WDMAICSA APPROVED CONFIGURATIONS NON-IMPACT 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA BUILDING CODE,6TH EDITION(2017)..CONFIGURATIONS NOTED AS HVHZ DESIGN APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE CONFIGURATION HVHZ PRESSURE IMPACT ACCEPTABLE FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. APPROVEDRATING RATING LOCK NOTE: 1 LOCK ASSEMBLY 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT 54"x7T'EQUAL LITE YES +50/-50 PSF (ITEMS 23-25)ALLOWED FOR PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 24"x7T'EQUAL LITE YES +501-50 PSF 24°X77"MAX.SIZE ONLY. ALL 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS 45" 86"EQUAL LITE YES +50/-50 PSF OTHER CONFIGURATIONS x LIMITED BYASTM E-1300 GLASS TABLES,AND TESTED WATER AND REQUIRE 2 LOCK ASSEMBLIES STRUCTURAL PRESSURES. 53"x86"EQUAL LITE NO +40t 50 PSF NONE 4,THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE W1 FULL SCREEN INSECT SCREEN NOTE: ALL THE INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE 53"x86"EQUAL LITE NO +50/-50 PSF SIZES EXCEPT 53"X86"MAY USE CONFIGURATIONS SHOWN IN THE ELEVATIONS. INSTALL PRODUCTS W/HALF SCREEN FULL SCREEN 53 HALF SCREEN WITH MAXIMUM SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT, 42 x82"ORIEL NO +501-50 PSF AT FULL DESIGN PRESSURE AND WITH FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. FOR FULL PRODUCT CONSTRUCTION DETAILS 54"MAX. SEE NCTL TEST REPORTS 210-4067-02/02A/03/03A,AND 11"MAX.ON 24"MAX.WINDOW WIDTH 210.4083-03/04/05A/05C/06B/06C. WINDOW WIDTH 6"MAX. 14"MAX.ON CENTER, 5.MINIMUM GLAZING IS INSULATING GLASS 1/8 ANNEALED+1/2"GED FROM STAINLESS STEEL INTERCEPT SPACER+118"ANNEALED,GLAZED WITH CENTER,TYP. � CORNER, TYP. I 6"MAX.FROM 6.THE 4/3 ALLOWABLE STRESS INCREASE FAC OR(SHORT-TERM 111 TYP. CORNER,TYP. INCREASE FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS -- FOR THIS SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE INTO WOOD SUBSTRATE. I _ O O 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS) p y� n 2}a p AND ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND >r E M>C 0 F SHALL BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR X w ;r: ��C X �y+�W AS APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). Q ti �C Lu cC Z W_ BUCKING,OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY 2 w ¢S Lucas DESIGNED&INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO io O Z It. Z a Turner TRANSFER SUPERIMPOSED LOADS TO THE STRUCTURE. WITH O 1- O co V O "' ti O 2017-12-28 MASONRY OPENINGS,WOOD BUCKS ARE OPTIONAL. of = O0 Z a O �`Z 16:26+19:00 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE 2 h n 0 3 H Co p COATED OR OTHERWISE PROTECTED TO PREVENT GALVANIC r XX REACTIONS. WOOD BUCKS,IF USED,SHALL BE PRESSURE TREATED, U A � N lL m WITH EITHER A TREATMENT OR COATING COMPATIBLE WITH THIS Rty°, SILLANCHOR PRODUCT. SILL ANCHOR 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING SPACING SAME AS HEAD SPACING *ar N. 58201 'i SAME AS HEAD ce COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER WINDOW MATERIALS. 54"x77"EQUAL LITE ELEVATION 24"x77"EQ. LITE ELEV. '°'•SrA7E Oo.•s'�,.' 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY A +�''SSj.,.Ok....FLORIDA REGISTERED PROFESSIONAL ENGINEER ON A SITE-SPECIFIC TABLE OF CONTENTS NORTHEAST BUILDING PRODUCTS BASIS. SHEET DESCRIPTION 4280 Aramingo Ave.,Philadelphia,PA 19124 r7� 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER 1 NOTES,ELEV., Ph.(215)535-7110 www.camelotwindows.com 12/27/2017 . P.E. DOCUMENT. INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE CONFIG TABLE SHEET DESCRIPTION: DATE DRAWN: Lucas A.7/2017 RESPONSIBILITY OF OTHERS AND ARE NOT ADDRESSED BY THIS 2 ELEV.,GLAZING NOTES,ELEVATION 4/13/2017 FL PE#58201 3 VERTICAL SECT. 1239 Jabara Ave. 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 4 HOR1Z.SECTIONS SCALE: NTS REV:A SHEET 4. North Port,FL 342$8 5 BOM,PART DWGS DRAWING:FPA-WINFORCE-DH-NI SHEET: 1 OF 5 Ph.941-380-1574 WINFORCE DOUBLE HUNG WINDOW, NON-IMPACT 45"MAX. 53"MAX. WINDOW WINDOW 42"MAX. 11"MAX. WIDTH 6"MAX. 12"MAX, WIDTH 6"MAX WINDOW ON CENTER, FROM ON CENTER, 14"MAX. WIDTH 6"MAX.FROM ON CENTER, FROM TYP. CORNER, TYP• CORNER, -n,P � CORNER, TYP. TYP. TYP. O� p O� N o (WE W H Cl) LL W H LL Z (� Z / = W Q (a 0 x W... aop � !; Cop Nm p Qw 0 w z_ � 1 z I— z W` N O W N O W f U ❑ V p V cc)p & Cl)� cv)� N 2 SILL ANCHOR SILL ANCHOR SILL ANCHOR SPACING SPACING SPACING SAME AS HEAD SAME AS HEAD SAME AS HEAD 45"x86" EQUAL LITE ELEVATION 53"x86" EQUAL LITE ELEVATION 42"x82"ORIEL ELEVATION SEE TYPICAL 1/2"GED 1/8"ANNEALED GLAZING 20 22 SEE LOCK GLASS STAINLESS STEEL DETAIL NOTE, ,c>vs'•. INTERCEPT SPACER SHEET 1 '•�•��'''jo see s ;p2mpy GE SCS2801 D — 1/8"ANNEALED SILICONE _ 16 _ GLASS ;po: STn7€ of ;car 17 D ',,s���A��N``• 36 34 NORTHEAST BUILDING PRODUCTS o 0 EXT. 4280 Aramingo Ave.,Philadelphia,PA 19124 �Z Ph. 215 535-7110 www.camelotwindows.com 8 9 D � rn c ) 12/27/201 7 EXT. INT. N H Z SHEET DESCRIPTION: DATE DRAWN: Lucas A.Turner,P.E. TYPICAL GLAZING � m ELEVATIONS,GLAZING DETAIL 4/13/2017 FL PE#58201 MEETING RAILS DETAIL 1239 Jabara Ave. DETAIL SCALE: NTS REV:A North Port,FL 34288 DRAWING:FPA-WINFORCE-DH-NI SHEET: 2 OF 5 Ph.941-380-1574 WINFORCE DOUBLE HUNG WINDOW, NON-IMPACT SEE GENERAL ANCHOR NOTES,SHEET4. MIN.EDGE DIST., SEE TYP.GLAZING APPLIES TO BOTH DETAIL SHEET 2 9 SUBSTRATE EXT.AND INT.SIDES, z_Lou w� BY OTHERS, SEE TABLE 1 g U Q 15 4 SEE TABLE 1 w I— EXT. INT. CLEARANCE SEALANT BY 30 HOLE AND PLUG INSTALLER 10 D O- INSTALLATION FASTENER,SEE 1 1 TABLE 1,SEE aLOCATIONS V U �� SHEETS 1-2 cn 15 0� 2 U SEALANT BY ❑ I g INSTALLER _ 1 0 35 STRUCTURAL SILICONE D INSTALLATION - r FASTENER,SEE MIN.EDGE DIST., o w SUBSTRATE TABLE 1,SEE z w w EXT. INT. m w m BY OTHERS, APPLIES TO BOTH LOCATIONS g m¢ EXT.AND INT.SIDES, SHEETS 1-2 w l— SEE TABLE 1 SEE TYP.GLAZING SEE TABLE 1 DETAIL SHEET 2 CLEARANCE HOLE AND PLUG TYPICAL HEAD VERTICAL SECTION TYPICAL SILL VERTICAL SECTION ................ Y` :� 'P���. Na 58204 �P TABLE 1:EQUAL LEG/FLANGE FRAME INSTALLATION ANCHOR REQUIREMENTS TABLE a ? * S+= NOTE: ALL ANCHORS ARE PAN HEAD OR HEX WASHER HEAD = = Fa 9. STAIE OF tkly SUBSTRATETYPE ANCHOR TYPE MIN.EMBED. MIN.EDGE DIST. ?"FS <Qa10 1G��1,� CONCRETE(2.0 KSI MIN) 3/16"ITW TAPCON 1" 1 1/8" 0 �;s`0 HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" NORTHEAST BUILDING PRODUCTS 4280 Aramingo Ave.,Philadelphia,PA 19124 yZ CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" Ph.(215)535-7110 www.camelotwindows.com 12/27/2017 2X MIN.SOUTHERN PINE WOOD(G=0.55) #10 GRADE 5 WOOD SCREW 1-3/8" 1" SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. HEAD/SILL INSTALLATION 4/13/2017 FL PE#58201 16 GAUGE(0.060")MIN.STEEL STUD,33KSI #10-16 HILTI KWIK-FLEX OR ITW 1/2" 1239 Jabara Ave. YIELD MIN.,OR 1/8"ALUM.6063-T5 MIN. TEKS SELF-DRILLING SCREW FULL SCALE: NTS REV:A North Port,FL 34288 DRAWING:FPA-WINFORCE-DH-NI SHEET: 3 OF 5 Ph.941-380-1574 WINFORCE DOUBLE HUNG WINDOW, NON-IMPACT 1/4"MAX. 1/4"MAX. INSTALLATION FASTENER, SHIM SPACE INSTALLATION FASTENER, SHIM SPACE SEE TABLE 1,SEE SEE TABLE 1,SEE LOCATIONS SHEETS 1-2 MIN.EMBED., LOCATIONS SHEETS 1-2 MIN.EMBED., SEE TABLE 1 SEE TABLE 1 U) CLEARANCE. u) CLEARANCE w J = F w HOLE AND PLUG w = F_ w r HOLE AND PLUG c0IL ZU) oaLL�z � w z mp o � ❑ INT. z -0� wm� ❑ INT. rn W U) oo (A W (A o0 0 � °o a SEE TYPICAL o a GLAZING DETAIL, SHEET.2 ❑ ❑ o SUBSTRATE T• SUBSTRATE 0 EXT. BY OTHERS, BY OTHERS, 5 SEALANT BY SEE TABLE 1 SEE TABLE 1 INSTALLER SEALANT BY 3 18 9 37 INSTALLER TYPICAL JAMB HORIZONTAL SECTION TYPICAL OPTIONAL ADD-ON FLANGE SECTION, JAMB SHOWN, MAY ALSO BE USED HEAD/SILL GENERAL ANCHOR NOTES: y�pry �cE+.... 1.INSTALL ONE ANCHOR AS INDICATED IN DETAILS ON SHEETS 3 AND 4 AT EACH LOCATION 5e201 SHOWN IN THE ELEVATIONS ON SHEETS 1 AND 2. c x # 2.INSTALL SHIMS AT EACH ANCHOR LOCATION WHERE A GAP OF 1/16"OR GREATER EXISTS srnTe of .+L BETWEEN PRODUCT FRAME AND SUBSTRATE. ,o-. w� 3.SHIMS SHALL BE LOAD-BEARING(PLASTIC OR METALLIC)AND CAPABLE OF TRANSFERRING LOADS TO SUBSTRATE. 4.SPECIFIED ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL FINISH OR NORTHEAST BUILDING PRODUCTS STUCCO,BY OTHERS. FOR ATTACHMENT TO METAL SUBSTRATES ENSURE FULL THREAD 4280 Aramingo Ave.,Philadelphia,PA 19124 Z� ENGAGEMENT THROUGH METAL WALL WITH MIN.3 THREADS BEYOND. Ph.(215)535-7110 www.camelotwindows.com 1212712017 5.FOR MASONRY WITH WOOD BUCKS LESS THAN 1-1/2"THICK,EMBEDMENT SHALL BE SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. BEYOND WOOD BUCKS AND INTO MASONRY. WOOD BUCKS ARE OPTIONAL WITH MASONRY JAMB INSTALLATION/ALT.FLANGE 4/13/2017 FL PE#58201 INSTALLATIONS WHERE MASONRY EDGE DISTANCE CONDITIONS ARE MET WITH NO BUCKS. 1239 Jabara Ave. WOOD BUCKS 1-1/2"THICK OR GREATER SHALL HAVE EMBEDMENT INTO THE WOOD BUCKS. SCALE: NTS REV:A North Port,FL 34288 6. ENSURE 3"MIN.ON-CENTER SPACING BETWEEN ANY TWO INSTALLATION ANCHORS. DRAWING:FPA-WINFORCE-DH-NI SHEET: 4 OF 5 Ph.941-380-1574 BILL OF MATERIALS WINFORCE DOUBLE HUNG WINDOW, ITEM DESCRIPTION PART NO. SOURCE MATERIAL NON-IMPACT 1 HEAD 10005160 DECEUNINCK PVC 2 SILL 10005161 DECEUNINCK PVC 432 15 3 JAMB 10005162 DECEUNINCK PVC ❑ ❑ 432^ 4 SILL EXTENSION 10001 DECEUNINCK PVC �E O 5 ADD-ON FLANGE 10008348341 DECEUNINCK PVC 6 SASH STOP 10008483 DECEUNINCK PVC 7 NItN7 0 N VIN 8 WEATHER STRIPPING .187 BK X.220 HT ULTRA FAB FIN PILE Q p 00�� NC" 9 WEATHER STRIPPING .187 BK X.290 HT ULTRA FAB FIN PILE 10 WEATHER SEAL-SILL FOAM FILLED BULB AMESBURY FOAM/POLYETH. O ❑ ❑ 11 BALANCE CLIP ROLLER TILT-RT562 CALDWELL O 12 FRAME SCREWS-SILL TO JAMB #8 X 1/2"PPH-SS MERCHANTS ST.STEEL 13 BALANCE SCREWS #8 X 7/8"PFH -SS MERCHANTS ST.STEEL 14 -32^ 15 TOP/BOT.LIFT RAIL 10005541 DECEUNINCK PVC 16 KEEPER RAIL 10005543 DECEUNINCK PVC ❑�� 17 LOCK RAIL 10005542 DECEUNINCK PVC �{ 132 12^ 18 TOP/BOT.STILE 10008206 DECEUNINCK PVC Jj_ -� 19 BULB SEAL 10008206 DECEUNINCK PVC 20 GLAZING BEAD-34'IG NON-IMP. 10005456 DECEUNINCK PVC c=104 21 PIVOTBAR 16Y513 STAINLESS STEEL CALDWELL ST.STEEL Nc7 ❑ ��N a° 22 PIVOT BAR SCREW #6 x 5/8"PPH TEK-SS MERCHANTS ST.STEEL D `:IN 23 LOCK D2100AL-XX ASHLAND TIN-ZINC 35 36 15 v 24 LOCK SCREW #8 X 1"PAINTED PFH MERCHANTS STEEL 25 KEEPER 13999-999-XX ASHLAND TIN-ZINC ❑ DE 26 KEEPER SCREW #6 X 3/4"PAINTED PFH MERCHANTS STEEL 27 VENTSTOP 1760 VISION VINYL , 28 TILT LATCH-UPPER SASH 7397 FC-R/7397 FC-L VISION VINYL O 29 TILT LATCH-LOWER SASH 2OF0041 LH /20F0042 RH CALDWELL VINYL 11 30 TILT LATCH SCREW-LOWER SASH #8 X 3/8"PPH TEK MERCHANTS STEEL 2" 1 11" 31 TILT LATCH THUMB BUTTON 20F000501/502 CALDWELL VINYL T[T(o_�i 16 2 CENTER FIN WEATHERSTRIPPING .270 BK.x.270 HT.Adhesive ULTRAFAB FIN PILE i34 LOCK RAIL REINFORCEMENT 10300266 ASTRO SHAPES 6005-T5 ALUM. SIN35 TOP LIFT RAIL REINFORCEMENT 10300159 ASTRO SHAPES 6005-T5 ALUM.36 KEEPER/BOTTOM LIFTRAIL REINF. 10300159 ASTRO SHAPES 6005-T5 ALUM. ' v37 STILE REINFORCEMENT 10300166 ASTRO SHAPES 6005-T5 ALUM. 37 —i _r*; ,,, 5p2ot ;*= �0� STATE OF :4 ;:104 123„ 23 +''%.Scion a�' 32 O 132^ 11^ ,,,n,t�" 8 NORTHEAST BUILDING PRODUCTS _ ❑ 4280 Aramingo Ave.,Philadelphia,PA 19124 Z Z 23"Y IN I l_ _ J I NIA Ph.(215)535-7110 www.camelotwindows.com 12/27/2017 ❑�,= IN L iJ SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. O32 BILL OF MATERIALS,PART DWGS 4/13/2017 FL PE#58201 16 17 D� 34 1239 Jabara Ave. SCALE: NTS REV:A North Port,FL 34288 DRAWING:FPA-WINFORCE-DH-NI SHEET: 5 OF 6 Ph.941-380-1574 8/10/2618 Florida Building Code Online F', -a�Oelt ®R-, 13CIS Home Log In User Registration t Hot Topics Submit Surcharge i stats&Facts Publications p Links i Contact Us BCIS Site Ma Search J Flo'ida Product Approval db r 0 USER:Public User Product Approval Menu>Product or Al2plication Search>AgPlication List>Application Detail FL# FL22293-R2 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments public comment:Ext.Ann. Lite does not comply w/2411.1.11.05/18/18 Archived Product Manufacturer Northeast Building Products Inc. Address/Phone/Email 4280 Aramingo Ave Philadelphia,PA 19124 (215)535-7110 L.Knowles@nbpmail.com Authorized Signature Lucas Turner Luke@TurnerEC.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Windows Subcategory Horizontal Slider Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Scott Wolters,PE Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/l.S.2/A440 2011 ASTM E 1886 2005 ASTM E 1996 2009 TAS 201/202/203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 03/13/2018 Date Validated 04/05/2018 https://www.floridabuilding.org/pr/pr--app—dtl.aspx?param=wGEVXQwtDquYPIHVa8bqMSirRyIl4oTUDmOyUStl%2bG6uOwkbORXKLw%3d%3d 1/2 8/10/1019 Florida Building Code Online Date Pending FBC Approval Date Approved 04/11/2018 Summary_of Products FL# Model,Number or Name 1 Description .... ........................ ........_....-.___..._.......... ...... ........................._...._...._-_.._._..._....................._............._- 22293.1 WinForce Horizontal Slider Impact WinForce PVC Horizontal Slider XX and XOX Window,Large Missile Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22293 R2 C CAC 86-155 AR.pdf Approved for use outside HVHZ:Yes FL22293 R2 C CAC86-163 .AR.pdf Impact Resistant:Yes FL22293 R2 C' CAC 86- 9 .AR.pdf Design Pressure:N/A FL22293 R2 C CAC 86-203CAR.pdf E Other:Please see Certifications,Installation Instructions,and FL22293 R2 C CAC 86- 0 AR.p�df I Evaluation Report for additional information,design pressures, FL22293 R2 C CAC 86-212CAR.p_df ! and configurations that are approved for the HVHZ. FL22293 R2 C CAC 86- 1 AR.p-df FL22293 R2- C CAC 86- 17 AR.pdf j FL22293 R2 C CAC 86-220CAR.pdf FL22293 R2 C CAC 86-401 AR.pdf FL22293 R2 C CAC86-406 .AR.pdf F1 22993 R AC 86-408CAR.pdf FL22293 R2 C CAC 86-416CAR.pdf FL22293 R2 C CAC 86-418 AR.pdf FL22293 R2 C CAC 86-4 4 AR.Rdf [. Fl 7 3 R C CA 86-4 SCAR pdf Quality Assurance Contract Expiration Date i 01/31/2021 Installation Instructions I FIFI 22293 R? TI FPA-WinForce-SI-1 M-B pdf Verified By: Lucas A.Turner PE#58201 j Created by Independent Third Party:Yes Evaluation Reports — FL22293 R2 AF FvalReport-WinForce--c;L-LM-13-pdf Created by Independent Third Party:Yes ____.._._._----._._--_.______�_� 22293.2 WinForce Horizontal Slider Non- WinForce PVC Horizontal Slider XX and XOX Window,Non.- Impact Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL22293 R2 C CAC 86-154CAR.Pdf Approved for use outside HVHZ:Yes FL22293 R2 C CAC 86-168CAR.pdf [I Impact Resistant:No FL22293 R2 C CAC 86-400CAR.pdf Design Pressure:N/A FL22293 R2 C CAC 86-40 AR.Rdf Other:Please see Certifications,Installation Instructions,and FL22293 R2 C CAC 86-405CAR.pdf Evaluation Report for additional information,design pressures, FL22293 R2 Q CAC 86-407 AR.pdf and configurations that are approved for the HVHZ. FI 22293 R AC 86-4 OCAR.pdf FL22293 R2 C CAC86-4 3 .AR pdf FL22293 R2 C CAC86-4 AR.Rdf FL22293 R2 C CAC 86-4 i5 AR.pdf Quality Assurance Contract Expiration Date 01/31/2021 Installation Instructions FL22293 R2 IT FPA-WinForceS -NI-B.pdf Verified By: Lucas A.Turner PE#58201 Created by Independent Third Party:Yes Evaluation Reports FL22293 R2 AE EvalReoort-WinForce-SL-NI-B.Rdf Created by Independent Third Party:Yes 8mtk Next Contact Us;:2601 Blair Stone Road,Tallahassee FL 32399 Phone;850-487-1824 The State of Florida is an AA/EEO employer.Sppyljgh[2007-20t3 State of Florlda.::Privacy Statement;:Accessiblli[v Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic mall to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address If they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here_• Product Approval Accepts: tw_ � tOtrtA Credit Card Safe IMEM https://www.flaridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDquYPIHVa8bgMSirRyl14oTUDmOyUStl%2bG6uOwkbORXKLw%3d%3d 2/2 GENERALNOTES WINFORCE HORIZONTAL SLIDER WINDOW' 1.THE PRODUCT SHOWN HEREIN CONSTRUCTED FROM DECEUNINCK EXTRUDED RIGID PVC FRAMES HAS BEEN TESTED TO AAMANVDMA/CSA NON-IMPACT 101/I.S.2/A440-08/11,AND MEETS THE REQUIREMENTS OF THE FLORIDA APPROVED CONFIGURATIONS BUILDING CODE,6TH EDITION(2017). CONFIGURATIONS NOTED AS HVHZ APPROVED HAVE ALSO BEEN TESTED TO TAS202-94,AND ARE ACCEPTABLE DESIGN REQUIRED HVHZ IMPACT FOR USE IN THE HIGH VELOCITY HURRICANE ZONE. CONFIGURATION GLAZING` APPROVED PRESSURE RATING 2.THIS PRODUCT IS NON-IMPACT AND REQUIRES THE USE OF IMPACT RATING PROTECTIVE DEVICES(SHUTTERS)IN WINDBORNE DEBRIS REGIONS. 74"x63"XX 2SL TYPE A YES +50/-50 PSF 3. THE DESIGN PRESSURES INDICATED IN THIS DRAWING ARE AS LIMITED 84"x66"XX 2SL TYPE B YES +50/-50 PSF BY ASTM E-1300 GLASS TABLES,AND TESTED WATER AND STRUCTURAL PRESSURES. 104"x66"XOX EQUAL LITE TYPE A YES +50/-50 PSF 4.THIS DOCUMENT ADDRESSES PRODUCT ANCHORAGE TO ACHIEVE THE 93"x66"XOX 1/4-1/2-1/4 TYPE A SASH YES +55/-55 PSF NONE INDICATED DESIGN PRESSURES AT THE INDICATED SIZES,IN THE TYPE B FIXED CONFIGURATIONS SHOWN IN THE ELEVATIONS. 'X'INDICATES OPERABLE PANEL,'O'INDICATES FIXED PANEL. INSTALL PRODUCTS WITH MAXIMUM 104"x66"XX 2SL TYPE B NO +40/40 PSF SHIM GAP,MINIMUM EDGE DISTANCE AND EMBEDMENT,AND WITH FASTENER TYPE AS SHOWN IN THE DETAILS AND AS INDICATED IN TABLE 1. 104"x66"XOX 114-1/2-1/4 TYPE B NO +40/-40 PSF FOR FULL PRODUCT CONSTRUCTION DETAILS SEE NCTL TEST REPORTS 2104067-01/01AI01B/01C,AND 2104081-01 B/01C/02B/03B/04A/04C 'SEE GLAZING DETAILS,SHEET 2 5.APPROVED MINIMUM GLAZING IS AS SHOWN IN GLAZING DETAILS ON SHEET 2 AND AS SPECIFIED IN ALLOWABLE CONFIGURATIONS TABLE ON INSTALLATION 74"MAX.WINDOW WIDTH THIS SHEET. FASTENER 10-1/2"MAX. 6"MAX. 6.THE 4/3 ALLOWABLE STRESS INCREASE FACTOR(SHORT-TERM INCREASE LOCATION,TYP. FROM FACTOR)HAS NOT BEEN USED IN THE ANCHOR ANALYSIS FOR THIS F ON CENTER, CORNER, SYSTEM. THE 1.6 Cd FACTOR WAS USED IN THE ANALYSIS OF ANCHORAGE I TYP• TYP, INTO WOOD SUBSTRATE. 7.THE OPENING SUBSTRATE MATERIALS(FRAMING,MASONRY,BUCKS)AND �- ATTACHMENT OF BUCKS TO THE SUBSTRATE ARE BY OTHERS AND SHALL !%` 32-5/8"MAX. BE VERIFIED BY THE ARCHITECT OR ENGINEER OF RECORD OR AS APPROVED BY THE AUTHORITY HAVING JURISDICTION(AHJ). BUCKING, o DLO,TYP. w OPENINGS,&BUCKING FASTENERS MUST BE PROPERLY DESIGNED& 0 X X m LUCBS INSTALLED BY OTHERS IN ACCORDANCE WITH THE FBC TO TRANSFER u 3: Turner SUPERIMPOSED LOADS TO THE STRUCTURE. WITH MASONRY OPENINGS, w m p 2018-03-13 WOOD BUCKS ARE OPTIONAL. w z 21:43+20:00 8.DISSIMILAR MATERIALS THAT COME INTO CONTACT SHALL BE COATED O L OR OTHERWISE PROTECTED TO PREVENT GALVANIC REACTIONS. WOOD U H BUCKS,IF USED,SHALL BE PRESSURE TREATED,WITH EITHER A W r �- ,����"''DREl4T TREATMENT OR COATING COMPATIBLE WITH THIS PRODUCT. r,U CENsfi L;Qg!.,� a`.... , . 9.ALL ANCHORS USED SHALL BE OF A MATERIAL OR HAVE A COATING z SILL ANCHOR SPACING O �30 562Q1 :P G COMPATIBLE WITH THE PRESSURE TREATED WOOD BUCKS AND ALL OTHER SAME AS HEAD WINDOW MATERIALS. 74"x63"XX 2SL ELEVATION 10.ALL HARDWARE&FASTENERS SHALL BE IN ACCORDANCE WITH THESE O,c., DRAWINGS,OR AS APPROVED,SIGNED,AND SEALED BY A FLORIDA %,FS' REGISTERED PROFESSIONAL ENGINEER ON ASITESPECIFIC BASIS. TABLE OF CONTENTS %.S�o�;� ��� 11.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER SHEET DESCRIPTION NORTHEAST BUILDING PRODUCTS INFILTRATION RESISTANCE OF THE INSTALLED PRODUCT SHALL BE THE 1 NOTES,ELEV., 4280 Aramingo Ave.,Philadelphia,PA 19124 i RESPONSIBILITY OF OTHERS AND ARE NOTADDRESSED BY THIS CONFIG.TABLE Ph.(215)535-7110 www.camelotwindows.com 3/12/201B DOCUMENT. 2 ELEV.,GLAZING SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. 12. FOR ADDITIONAL REQUIREMENTS SEE GENERAL ANCHOR NOTES, 3 XOX ELEV. NOTES,ELEVATION 4/13/2017 FL PE#58201 SHEET 5. 4 VERTICAL SECT. SCALE 1239 Jabara Ave. : NTS REV:B 5 HORIZ.SECTIONS North Port,FL 34288 6 BOM,PART DWGS DRAWING:FPA-WINFORCESL-NI SHEET: 1 OF 6 Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT 84"MAX.WINDOW WIDTH 104"MAX.WINDOW WIDTH 8-1/4"MAX.O.C.,TYP. 12"MAX.O.C.,TYP. INSTALLATION CENTER OF INSTALLATION CENTER OF FASTENER INTERLOCK 6"MAX. FASTENER INTERLOCK 6"MAX. LOCATION,TYP. 1 FROM LOCATION,TYP. FROM 3" CORNER, �3" CORNER, TYP. TYP. ' 37-5/8"MAX. —_ �:' 47-12"MAX. DLO,TYP. CO DLO,TYP. C7 0 � X X �� L� X X � LL io 0 w io 0 Lu mo z z_ �� �zz � o 2 � �° C, to C.) z li �0 NV� p SILL ANCHOR SPACING p SILL ANCHOR SPACING SAME AS HEAD SAME AS HEAD 84"x66"XX 2SL ELEVATION 104"x66"XX 2SL ELEVATION GED GED STAINLESS STEEL STAINLESS STEEL INTERCEPT SPACER 1/8"ANNEALED INTERCEPT SPACER 3/16"ANNEALED 1/8"ANNEALED GLASS 3/16"ANNEALED GLASS GLASS GE SCS2801 GLASS GE SCS2801 "Pt1DREbY T,,� E SILICONE EXT. SILICONE �.'�._' f�a 5B2Cf7 •tp ,7 D 17 D 'f S Ta7E OF :tV� OR FBC.SECT.2411.3.3.1 FBC.SECT.2411.3.3.1 . ........ COMPLIANT SETTING U w COMPL EM IANT SETTING w NORTHEAST BUILDING PRODUCTS BLOCKS 0 N I—? BLOCKS N I-- ,— �m O m g 4280 Aramingo Ave.,Philadelphia,PA 19124 Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 SHEET DESCRIPTION: DATE DRAWN: Lucas A.Turner,P.E. TYPICAL GLAZING TYPICAL GLAZING ELEVATIONS,GLAZING DETAILS 4/13/2017 FL PE 958201 1239 Jabara Ave. DETAIL,TYPE A DETAIL,TYPE ISSCALE: NTS REV:B North Port,FL 34288 DRAWING:FPA-WINFORCESL-NI SHEET: 2 OF 6 Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT 104"MAX.WINDOW WIDTH 104"MAX.WINDOW WIDTH INSTALLATION 9-MAX.O.C.,TYP. INSTALLATION 9"MAX.O.C.,TYP. FASTENER -CENTER OF CENTER OF LOCATION,TYP. r INTERLOCK 6"MAX FASTENER CENTER OF CENT.OF 6"MAX. �E INT'LOCK INTERLOCK FROM LOCATION,TYP. INTERLOCK 3-3 3- -1 _ 3 3. FROM - 3 CORNER, - CORNER, TYP. 3" 3-1 TYP. --T 31"MAX. 23"MAX.SASH DLO, C, DLO,TYP. ;E a: .0 0 w w m 0 w u- x 0 x C> w �X ul X 0 X (Do Z 0 Co 0 w , z CO Of �& 0 uJ 0 uj 47"MAX. a: 0 0 ul z a: FIXED DLO Uj z 0 SILL ANCHOR SPACING SAME AS HEAD C;z 0 SILL ANCHOR SPACING SAME AS HEAD 104"x66"XOX EQUAL LITE ELEVATION 104"x66"XOX 114-1/2-1/4 ELEVATION 93"MAX WINDOW WIDTH INSTALLATION —9"MAX.O.C.,TYP. FASTENER CENTER OF CENT.OF LOCATION,TYP. LOCK INTLOCK 6"MAX 3" FROM IN I. TERLOCK 3 3- 3.1 CORNER, .0 0-0- 000 TYP. 20-1/2"MAX.SASH DLO,TYP. S2 0 No 53?fit "."A w w LL x 0 X ;,gyp: SrATE OF r*4t4 ul 60 �0. z x C) .......%..**' z 0 41-1/2"MAX NORTHEAST BUILDING PROD Zo 0 :R 1-- a: z FIXED DLO'--J . U N UJI 4280 Aramingo Ave.,Philadelphia,PA 19124CTS :;-0 Ph.(215)535-7110 www.camelotwindows.com c; z 3/12/2018 0 SILL ANCHOR SPACING SAME AS HEAD SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. FL E 93"X66"XOX 1/4-1/2-1/4 ELEVATION XOX ELEVATIONS 4/13/2017 1239 P Jaba#58201ra Ave. SCALE: NTS REV-B North Port,FL 34288 DRA-1-1- --' -fINFORCESL-NI SHEET: 3 OF 6 Ph.941-380-1674 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT SEE GENERAL ANCHOR NOTES,SHEET5. SEE TYPICAL GLAZING MIN.EDGE DIST., DETAIL,SHEET 2 APPLIES TO BOTH EXT. INT. CLEARANCE SUBSTRATE EXT.AND INT.SIDES, zw_ W w BY OTHERS, m w GO 26 HOLE AND PLUG SEE TABLE 1 SEE TABLE 1 �m w ~Q 6 D o D INSTALLATION SEALANT BY 14 FASTENER,SEE INSTALLER TABLEI,SEE 4 O O O LOCATIONS 1 SHEETS13 11 3 zt y 0 3 _¢ _ U c m n n ��r=d 1 m 0WIL 403 mwm 9 14 INSTALLATION w H FASTENER,SEE SEALANT BY 6 O O O TABLE 1,SEE INSTALLER LOCATIONS 26 SHEETS 1-3 EXT. D DINT. CLEARANCE MIN.EDGE DIST., HOLE AND PLUG SUBSTRATE APPLIES TO BOTH BY OTHERS, EXT.AND INT.SIDES, SEE TYP.GLAZING SEE TABLE 1 SEE TABLE 1 DETAIL SHEET 2 TYPICAL HEAD VERTICAL SECTION TYPICAL SILL VERTICAL SECTION TABLE 1:EQUAL LEG/FLANGE FRAME INSTALLATION ANCHOR REQUIREMENTS TABLE s` NOTE: ALL ANCHORS ARE PAN HEAD OR HEX WASHER HEAD z� AT ov SUBSTRATETYPE ANCHORTYPE MIN.EMBED. MIN.EDGE DIST. CONCRETE(2.0 KSI MIN) 3/16"ITW TAPCON 1" 1 1/8" ' Its, ` NORTHEAST BUILDING PRODUCTS �Z HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" 4280 Aramingo Ave.,Philadelphia,PA 19124 CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1•' 1" Ph.(215)535-7110 www.ramelotwindows.com 3/12/2018 2X MIN.SOUTHERN PINE WOOD(G=0.55) #10 GRADE 5 WOOD SCREW 13/8" 1" SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. HEAD/SILL INSTALLATION 4/13/2017 FL PE#58201 16 GAUGE(0.060")MIN.STEEL STUD,33KSI #10-16 HILTI KWIK-FLEX OR ITW 1/2" 1239 Jabara Ave. YIELD MIN.,OR 1/8"ALUM.6063-T5 MIN. TEKS SELF-DRILLING SCREW FULL SCALE: NTS REV:B North Port,FL 34288 DRAWING:FPA-WINFORCESL-NI SHEET: 4 OF 6 Ph.941-380-1574 WINFORCE HORIZONTAL SLIDER WINDOW, NON-IMPACT 1/4"MAX. 1/4"MAX. SHIM SPACE SHIM SPACE SEE TYPICAL MIN.EMBED., SEE TYPICAL MIN.EMBED., 1 13 25 6 GLAZING DETAIL, 1 13 25 6 GLAZING DETAIL, SEE TABLE 1 SEE TABLE 1 SHEET 2 SHEET 2 w ~ w wa_0 ❑ INT. W° p t�W ❑ INT. ¢ m vim °dm chop = o z �0o� °- Z1-0 �< wolQ— O- � m wu) � v) wco ❑ a EXT. a EXT. 0 0 CLEARANCE CLEARANCE ° HOLE AND PLUG ° HOLE AND PLUG ❑ ❑ INSTALLATION ❑ ❑ INSTALLATION FASTENER,SEE FASTENER,SEE o TABLE 1,SEE o TABLE 1,SEE SUBSTRATE LOCATIONS SUBSTRATE LOCATIONS BY OTHERS, SHEETS 1-3 BY OTHERS, 2$ SHEETS 1-3 SEE TABLE 1 SEALANT BY SEE TABLE 1 SEALANT BY INSTALLER INSTALLER TYPICAL JAMB HORIZONTAL SECTION TYPICAL OPTIONAL ADD-ON FLANGE SECTION, JAMB SHOWN, MAY ALSO BE USED HEAD/SILL • J``�`i79RE6y����,' GENERAL ANCHOR NOTES: �csrvs•.•R�'. 1.INSTALL ONE ANCHOR AS INDICATED IN DETAILS ON SHEETS 4 AND 5 AT EACH LOCATION SHOWN IN THE ELEVATIONS ON SHEETS 1 THROUGH 3. 2.INSTALL SHIMS AT EACH ANCHOR LOCATION WHERE A GAP OF 1/16"OR GREATER EXISTS �� sr�te op BETWEEN PRODUCT FRAME AND SUBSTRATE. DOE•, c q r��: 3.SHIMS SHALL BE LOAD-BEARING PLASTIC OR METALLIC)AND CAPABLE OF '; a}9' TRANSFERRING LOADS TO SUBSTRATE. ,�''Sio....... a; 4.SPECIFIED ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL FINISH OR NORTHEAST BUILDING PRODUCTS STUCCO,BY OTHERS. FOR ATTACHMENT TO METAL SUBSTRATES ENSURE FULL THREAD 4280 Aramingo Ave.,Philadelphia,PA 19124 Z� ENGAGEMENT THROUGH METAL WALL WITH MIN.3 THREADS BEYOND. Ph.(215)535-7110 www.camelotwindows.com 3/12/2018 5.FOR MASONRY WITH WOOD BUCKS LESS THAN 1-1/2"THICK,EMBEDMENT SHALL BE SHEET DESCRIPTION: DATE DRAWN: Lucas A.Turner,P.E. BEYOND WOOD BUCKS AND INTO MASONRY. WOOD BUCKS ARE OPTIONAL WITH MASONRY JAMB INSTALLATION/ALT.FLANGE 4/13/2017 FL PE#58201 INSTALLATIONS WHERE MASONRY EDGE DISTANCE CONDITIONS ARE MET WITH NO BUCKS. 1239 Jabara Ave. WOOD BUCKS 1-1/2"THICK OR GREATER SHALL HAVE EMBEDMENT INTO THE WOOD BUCKS. SCALE: NTS REV:B North Port,FL 34288 6. ENSURE 3"MIN.ON-CENTER SPACING BETWEEN ANY TWO INSTALLATION ANCHORS. DRAWING:FPA-WINFORCE-SL-NI SHEET: 5 OF 6 Ph.941-380-1574 a BILL OF MATERIALS WINFORCE HORIZONTAL SLIDER WINDOW, ITEM DESCRIPTION PART NO. SOURCE MATERIAL NON-IMPACT 1 HEAD/SILUJAMB 10005163 DECEUNINCK PVC 2 3 HEAD/SILL TRACK INSERT 10300127 ASTRO SHAPES 6005-T5 ALUM. 1" 4 HEAD/SILL TRACK INSERT COVER 10008469 DECEUNINCK PVC 432 5 6 CENTER FIN WEATHERSTRIPPING .187 BK.x.290 HT. ULTRAFAB FIN PILE 7 W'STRIP 1"STRIP @KEEPER INT'LCK .270 BK.x.270 HT.ADHESIVE ULTRA FAB FIN PILE I 31., 6 CENTER FIN WEATHERSTRIPPING .187 BK.x.220 HT. ULTRA FAB FIN PILE 32 9 WEEP COVERS 900-003 LAWRENCE PLASTIC 10 11 HEAD/SILL TRACK SCREWS #8 x 5/8"PPH TEK MERCHANTS STEEL I U E O 12 AIM 13 PULL STILE 100055 DECEUNINCK PVC O �I O 14 TOP/BOTTOM RAIL 10005539 DECEUNINCK PVC ��II 15 KEEPER STILE El 10005543 DECEUNINCK PVC 16 LOCK STILE 10005542 DECEUNINCK PVC 17 GLAZING BEAD-3/4"IG 10005456 DECEUNINCK PVC 18 19 ROLLER 1146 VISION POLYPROPJ BRASS 20 LOCK-DUAL TECH PASSIVE D2100AL-XX ASHLAND NYLON 11„ 21 LOCK SCREW #8 X 1"PAINTED PFH MERCHANTS STEEL 2 22 KEEPER 13999-999-X0( ASHLAND TIN-ZINC 23 KEEPER SCREW #6 X 3/4"PAINTED PFH MERCHANTS STEEL 7" 24 �32 25 REINF.PULL&KEEPER STILE 10300159 ASTRO SHAPES 6005-T5 ALUM. 26 REINF.LOCK STILE&TOPBOT.RAIL 10300266 ASTRO SHAPES 6005-T5 ALUM. 27 FIXED LITE FLANKER STOPS 2991E VISION NYLON 28 JADD ON FLANGE 10008341 DECEUNINCK PVC SEE TYPICAL 16 26 21 20 22 11^ GLAZING 2 DETAIL 00 00 00 COIN LOIN `� �`, N�m NC7 25 `° `'•�ic tiSF�p�.. AUl No 5&20i t'f` 32 z113; STATH OF : •.�3/feel p p;ENp� 8 NORTHEAST BUILDING PRODUCTS 25 S I 4280 Aramingo Ave.,Philadelphia,PA 19124 z� a Ph. 215 535-7110 www.camelotwindows.com EXT. � ) 3/12/2018 15 26 U I NIA 28 v� SHEET DESCRIPTION: DATE DRAWN: Lucas A.Tumer,P.E. U BONI,PART DRAWINGS 4/13/2017 FL PE#58201 LOCK/KEEPER STILES DETAIL 23^ 1239 Jabara Ave. 32 SCALE: NTS REV:B North Port,FL 34288 DRAWING:FPA-WINFORCE-SL-NI SHEET: 6OF6 1 Ph.941-380-1574