Loading...
HomeMy WebLinkAbout18-20513 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20513 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20513 Issued: 11/28/2018 Address: 2987 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER Amount Paid: 17,790.47 Date Paid: 11/28/2018 Parcel Number: 25-26-21-0100-00000-0540 . _ CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION FEES BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 t/I,,/ k V/1"', 0jV -rear Ins ections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. 'CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. COKTRACTbA§SrINKTURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received OCT 2 9 2018 1 1 1 1 � � 1 1 Phone Contact for Permitting 813 363 _ 2891 17� I I I I I I I I . J1 1 1 1 1 1 Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 2987 Moulden Hollow Drive LOT# 0540 SUBDIVISION Hidden River Phase One B PARCEL ID# 25-26-21-0100-00000-0540 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION. BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2276 7 SQ FOOTAGE 1817 HEIGHT 1 Story BUILDING $ VALUATION OF TOTAL CONSTRUCTION tl�/ (ELECTRICAL $ 1 ® PROGRESS ENERGY Q W.R.E.C. AMP SERVICE PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS W1 ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES �J0 BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREK Y/N Address 4600 W. ress St.Ste 0,'Pampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N_J FEE CURREN Address 1034 Sk't r Road, mpa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 8, Bay , L 34674-5308 License# CF0042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREK Y/N Address P.O. Box 5 , Bay t, FL 34674-5308 License# I CAC058062 OTHER COMPANY =Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREK Y/N Address 4211 Shoal-L' a Blvd, Spring Hill, FL 34607 License# I CCCO57991 1111111111111111 1111111111111111111111111111111111111111111111111.1 RESIDENTIAL Attach(2)PlotPlans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. ■Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE��F0£ED RESTRICT IONS: The undersigned un derstands th at this permit pe be subject to"deed" ,6~+ri,*o"�s. which may be more restrictive than County regulationa The undersigned.assumes responsibility for oompliar�ce with any applicable deed restrictions. - .��� ___ �[ UNLICENSED CONTRACTORS CONTRACTOR��� ��������� RESPONSIBILITIES: � �e ownmr ham hired o Contractor or contractors bn undertake work, they may ba required bnbe licensed in accordance with state and local regulations. If the contractor is not Uoanamd as required by |em' both the owner and contractor, be cited fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—LicePsing Section at 727-847- 8009. Furthermore, if the owner has hired m contractor or nontnaobnro, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the oontnacbor, that may be on indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION ]88PAC37UTlL1TIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may to the construction of new bui|dingo, change of use in existing buildings, or expansion of existing bui\dinga, as specified in Pasco County Ordinance number8Q-O7 and 90-07. as amended. The undanaigped also undenstands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve o certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must b�paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713` Florida Statutes, mmammeoded): {f valuation uf work io$2,5UO.00ormore, | certify that |, the oppUoont, hava'beon provided with m copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared,by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", | certify that | have obtained a copy of the above described document and promise in good faith to deliver itto the"mwner" prior hocommencement. CONTRACTOR'0VOWNER"SAFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in comp|ioncevvith all applicable laws regulating-construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating cnnotructinn. County and City uodsm, zoning nygu|odonn. and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended xwork, and that it is my responsibility to identify what,actions I must take to be in compliance. Such ogencieo'ino|ude but are not limited to: - Department ofEnvironmental Protection-Cypress 8myheods. Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management D|sthct-VVoUa, Cypress 8myheads. Wetland Areas, Altering Watercourses. - Army Corps ofEngineens'GeawoUe. Donha. Navigable Waterways. - Department of Health,8 Rehabilitative Services/Environmental Health Unit-AeUs, Wastewater Tneednoant. Septic Tanks. - UG Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authorit/-Runvxoyo. | understand that the fdUmminQ restrictions apply to the use of fill: . - Use of fill io not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Rood Zone "A", it is understood that s drainage plan addressing a .compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State ofFlorida. ' - If the 5U material is to be used in Flood Zone "A" in connection with a permitted building using stem vvaU construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to advonemk/ nfhaot adjacent pnopartiea, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |ome than one (1) acre which are elevated by fill, on engineered drainage plan is required. If amth AGENT FOR THE OWNER, I. i !i good faith t inform the owner ofthe permitting conditionsset forth |n this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority,to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless-the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the,permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension.. If work ceases for ninety,(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS G CONSULT WITH YOUR LENDER OR AN ATTPkttg1BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER uuAGENT CONTRACTOR - - Subscribed and sworn to(or Waffia)before me this Subscribed and sworn-to-(or affirmed)before me this WRo islare per onally knowgg me or-harahave produced- Who is/are personally known to me or hasihave pfe Notary Public Notary Public Commission No. FF98537 Commission No. PF98537 ElissaM.Holleran Elissa M.Bolleruo Name of Notary twed.Printed or stamPed Name of Notary typed,printed or stamped ����� � Lennar Homes-2987 Moulden Hollow Drive 2,276 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,790.47 o.. t COBI US" City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 2-%p 97 AZOyG�� Permit Type: 2Z7 (a 39 Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ L i This comment sheet shall be kept with the permit and/or ans. NOV 2 7 2018 Kalvi er—Plans Examiner Date on ctor an omeowner (Required when comments are present) i illiil lilii 1111i ii11i illli lili[illli 11111 ilili iliii Nii illi 20181.9 Rcpt:2008645 -Rec: 10.00 DS: 0.00 IT: 0.00 11/27/2018 K. S. , Dpty Clerk PAULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER 11/27/2018 10:43am 1 of 1 OR BK 9822 PG 2366 Permit No. Parcel ID No 25-26-21-0100-00000-0540 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 54 Street Address: 2987 Moulden Hollow Drive zephryhills FL 33541 2. General Description of improvement Single Family Residence!Pooi!Screen Enclosure!Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (if other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: . N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes. LLC Name 4600 W Cypress St,Ste 200 Tampa FL.,33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Ltenor's Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT iN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WiTH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PiNELLAS �= Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 9 day of October ,by Steve Robert Smith as Vice President (type of aut�ctty�r,trustee,attorney in fact)for Lennar Homes LLC (name of pa a fbf whom Instrument inns executed)., Personally Known 2 QR Produced Identification❑ Nota Slgn Type of Identification Produced Name(Print) Elissa.Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,1 declare that 14 have read the foregoing and that the facts stated In It are true to the best of my knowledge and belief. ELISSAM.HOLLERAti Signature of NaturhrPerson Signing Above CemmileJnnIFF886031 s p Extlre3 June 0,2020 wpdata/bcs/bcsform: dl++ IlondM>hiuTroyt'�Iril�uuriflcelOplirigtp Die� STATE OF FLORIDA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A i}" : TRUE AND CORRECT COPY OF THE DOCUMENT "1 ON FILE OR OF PUBLIC RECORD IN THIS OFFICE " WITNESS MY HAND AND F-ICIAL SEAL THIS DAY OF A 9 A PAUtAS.O'NEI CL RK COMPTROLLER BY DEPUTY CLERK 25-26-21-0100-00000-0540 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive- Saturday, November 24, 2018 Parcel ID 25-26-21-0100-00000-0540 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 2987 MOULDEN HOLLOW DRIVE ZEPHYRHILLS, FL 33540 Just Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 See Plat for this Subdivision Taxable Value $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 54 OR 9814 PG 778 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line_ Use _D_escriptionZoning Units_ Type Price ;Condition Value _ --- --i- - 1— 0100--� SFR MPUD —1 6,000.00 -SF _ .$4.50 j—1.00 _$27,000 2 0100 SFR MPUD 600.00 SF $0.90 i 1.00 $540 Additional Land Information _ _ Acres 0.15 iTax Areai 30ZH i FEMA __ Residential Code HDRVLPI Code � Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line IDescrI tion iYear !Units �Value No Extra Features Sales History - See All 6 sales Previous'Owner: DUNE FL LAND I SUB LLC Month/YearBook/Page Type_ _ 1DOR Code Condition Amount 11/2018—- 9814 / 0778 - - Warranty Deed j 05 -- Vacant Multi-Parcel Sale 09/2011 8606 / 3376 1 Warranty Deed 05 Vacant Multi-Parcel Sale 06/2010 ( 8360 / 1872 I Certificate of Title 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126250100000000540 11/28/2018 Lennar Homes-2987 Mollden Hollow Dr:2,276 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 Public Fee 1% TOTAL $ 2,067.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES . PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,194.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,795.47 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R40-1.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt.is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4.sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first-. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). I L.Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least_ 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. MI620.4 15. Smoke detectors are to be installed in accordance with R3111 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means'of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board"shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all_locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with,the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to:unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with.the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25. Blower door test and blown in insulation card shall be provided before C.O. 26. A copy of the energy cacls shall be with permit at all times. 27. Conv of final insulation report shall be..provided with.permit before.finab 2$i No fence:,pool or screen enclosure is.issued with this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) I SKETCH ONLY SEC. 25 , TWP. 26 S, RNG. 21 E. PLOT PLAN • NOT A BOUNDARY SURVEY BEARING BASIS: LOT 54 HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT 1� MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 660o_-00SO. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =_18_38 SQ.. FT. b ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 32__$Q, FT• "o UNDERGROUND FOOTER, STEM WALL, AND _ GARAGE = 406 gq, FT, II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI = N/A —SQ. FT. SHOWN. ww► = PROPOSED DRAINAGE FLOW PATIO = 23 SQ. FT. i;.i DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE CONC. DRIVE = 339 —SQ, FT. i NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & CONC PAD =9---SQ. FT. PRIVATE SIDEWALK = 72 Q. FT. ur DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: IMPERVIOUS =__4_L—_% t PAGE PRELIMINARY INDICATES STAGE AND ISAT IS SUBJECT IN TO LOT GRADING TYPE = A = 2719 SQ. FT. PROPOSED PAD ELEVATION = SOD =_3881 SQ. FT. CHANGE AND/OR REVISION. FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON L SIDE SETBACK = 10' RIGHT WAY = 720_00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 10' DRIVE APRON =__144 SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK = 240 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD = 336 SQ. FT. TO PROPERTY LINE. TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA = 7320.00 SO. FT. ** = 5' DRAINAGE EASEMENT DRIVEWAY =483 SQ. FT. SIDEWALK = 312 SQ. FT. SOD = 4217 _S0. FT. �0 250� C>o y27 o Q LOT 53 (66 ioo �O •'oo. O T 0 • '\ moo. s g5;1 r \ s o C� 0 *\ / 00 PLAT \ o/ BOUNDARY \ O �o..r LOT 55 Q \ M PC(P) Go PLAT N TRACT "L" \ \ f BOUNDARY HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) o LANDSCAPE& \ \ PROPOSED: � BUFER EASEMENT m LOWEST FLOOR ELEVATIONS: 3 LIVING AREA: 72.20' DESCRIPTION: GARAGE AREA: 71.66' ELEVATIONS REFERENCED TO m LOT 54, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL z AS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA u, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. a nz APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 Project Number: Square Feet: 6600.00 t LENNAR HOMES Z LEGEND: 0 (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, 2 F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT v REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, m U P= UTILITY POLE W F= WOOD FENCE 0. JOHN R.BEACH&ASSOCIATES,INC. Drawn ey: SMS SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JRB w ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: = 1"=30' NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 9/19/18 ACS O �o o THE ORIGINAL RAISED SEAL OF A FLORIDA SI TURE DA •0 LICENSED SURVEYOR AND MAPPER . . BEACH a Revisions: FLORIDA G. LAND SURVEYOR No. 2984 LB 4493 JEFF M. H TLEY LL -PROFESSiONAI SURVEYOR & MAPPER No.7123 �;'�• •t• 5�.+` -,�:�' »,,.��,s '�i ''°a,--?;.' '�' ,�Ay .�'r*^�� •�,.s"M�,�, w^''�i �ra w at ,c :.o a �� 'aey'� c�}i •- ''" wr' IMP FF 63 -,y# `y 1.'� V� C'i"3r•M 4 ..�,�.,.,-.-.mow^"`.. f 'P4 ed` M�'� 56 FF E ol owl pip _ •t•`", s. � S d p el • '' ,�. d �.`,ajj _ p.pr,�.p—'- M`'9+�' 4 11�,�, d��,"�� day f i FF ol Pk LK •- .,• �:"xv.'I,i� -'fH •'�� �' 4'a 'l!1 �W T * •'1 j�y�j %G� f _ ! w a:' c� „5 e a r• ...::cs..... elf, "- •••: I; ,LS.• .t ��` +1l` . 'p ,• •dr 6 it..r Q �ing/ •• '• in o• s d to :ARFA SCE did yea 171 ow Ole oo i a . . i PASCO COUNTY, FLORIDA Permit No. Date Permitted l(- 2�- Builder Name/Owner Name FPS LLe' Control#' County Parcel No. ��p- ,�, —bO/-6C ��-/OSdSu\bDiv: AddeA Address/Location Classification/Type of Use �2 m� 2, 2-76 'S�& TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2, 27�o Exempt ❑ Yes ❑ No How Determined Impact Fee Amount $. 3[ 3 �' Zone No. TAZ: SCHOOL IMPACT FEE '7 9�.Z g Account (056) Single-Family Detached House Amount $ , (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt �Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 26 q• Exempt ❑ Yes ❑ No How Determined i LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By I NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY I Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Zrsy PASCO COUNTY PAS i" DEVELOPMENT SERVICES C 873'I.Citizens:Drive Date:2/1?J2019 COUNTY' FLORIDA New Poit Richey,FL 34654 727-847-2411 NOT A PST Receipt#: 1830211 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100429010 1.00 1427574 $60.30 $60.30 1830211 2/12/19 Waste Single Family TOTALS: $60.30 $60.30 Receipt# Paid By Check# CC Auth#• Cashier ID Workstation Receint.Date Amt Paid 1830211 Check 1155446 BCCCP59W 02/12/2010 $60.30 Total Payments: $60.30 Payor Address Phone Lennar Homes, LLC Comments: 2987 Moulden Hollow DR Whlle you will be paying your bill with Pasco County Development Services;thedull amount of the eredit card or a-check fees;NOT"shown above;Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptP-OS V6.rpt 2/12/2019 Page 1 of 1 Jacqueline Boges From: City of Zephyrhills Support <support@zephyrhillsfl.zendesk.com> Sent: Thursday, November 29, 2018 5:07 PM To: Jacqueline Boges Subject: [Request received) 2987 moulden hollow dr bp*20513 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: htti)s://zephyrhilisfl.zendesk.com/hc/reguests/252854 ............ ................1-................"............ ........................... ..................................... ............. ................................. ................................. ............ ................. Jacqueline Boges Nov 29, 3:07 PM MST new service 2987 Moulden hollow dr bp#20513 This email is a service from City of Zephyrhills Support ( �b-�-- 5'- \ �f- dos 13 n e Jet Stream° Ultra Blowing Wool Insulation kNAU ��C�JU�TXO Attic and Cavity Wall Card �� Ol' bL�J` if1 hwle{01gVe e;1e+cy Batts and Blankets Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'/40 internal corrugation,a minimum length recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed provide the full R-value. rate is 15-25 lbs/minute. R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label (R-Value)of: not to less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. R-38HD 10.25" R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum R-30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF insulation per 1,000 square feet Contents of this The weight per square R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. R-21 HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. R-19 6.25"" R-15HD 3.50" 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. R-11 3.50" R means resistance to heat How.The higher the R-value,the greater the insulating pourer.To get the marked R-value,it is essential that this insulation be installed property, R-8 " 2.50 "R-18ina5.5•cavity.conforms toASTMC62.50 ederal Open Attic Application Bag Net Weight-Nominal 321bs.,Minimum 31 Ills. Specification HH-1-521F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should Ba s/MSF Ba S/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more 9 9 resistance(R-Value)of: than: more than: be less than than: than: Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF 9521bs. 19.750" 19.750" R-Value Dimensions Framing Framing 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375' 16.375" R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875' 14.875" 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000" 13.000" 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125' 9.125' 2x8 22.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" 2x4 20.4 20.6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750' 6.750" 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750' 4.750" 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 4.000" R-38 2x6 17.0 17.2 Bag Net Weight-Nominal32lbs.,Minbnum37lbs. 2x8 16.7 17.0 Coverage and installation data were determined using a Vn Matic-II blmvng machine In third gear wdh 13'gate opening,2.0 psi air pressure and 150'of 3'intemally-conugated hose. 2x4 13.2 13.3 This product conforms to the performance requirements of ASTM C 764,Type I,and cancelled Federal specification HH-1-1030B,Type[,Class B.R-values are determined in accordance with C 687 and C 518. "R'means resistance to heal flax.The higher the R-ralue,the greater the insulating power.To get the marked R-value,B is essential that this insulation be installed propedy.If you do d yourself,gel instruc- R-30 2x6 12.9 13.1 Dons and follow them cerelulty.Instructions do not come mth this package. "Based on Third Party 2-year setting study,the predicted settlement over a 20-year period would be 1 percent or less.This amount of settling is thermally insignificant.Therefore,the installed and settled 2x8 12.6 12.9 Uddmesses are effecWely the same. 2X4 11.3 11.4 Volu-MaMl is a registered trademark of Unisul. R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 2x6 9.1 9.3 Attic Area R- at Inches 2x8 8.8 9.1 Sloped Ceilings R- at Inches 2x4 7.9 8.1 Walls R- at Inches R-19 2x6 7.7 7.9 Floors(over an unheated crawl space) R- at Inches 2x8 7.4 7.7 2x4 5.3 5.4 Crawl Space Pe' eter R- at Inches R-13 2x6 5.0 5.2 Date Installed F 2x8 4.8 5.0 Blown jypulation has been in all in conformance with the above rec g atio4to provide an R-value of: 2x4 4.3 4.4 R- 6 using (f bags of this insulation to cover square feet of area R-11 2x6 4.1 4.3 at a minimum thickness of /t inches. 2x8 3.8 4.1 UL Emimnmenr Insulation Contractor(signatunv)/� was♦ GREENGUARD Gold- �1 Keouf Insolotion building inwl"n"n-hived Company A 1 rr -Dal_ /,7 UL Environment GREENGUARD Gold,md is ' UL Emhonmem mlidomd w bee /'be 6-ldehyde , 111 UL Environment GREENGUARD Home Builder(signature) 0 Certifimtion Program'•' Pmduds ore mni6ed ro UL En.;- GREENGUARD smnd-k Fur bw d,emic"I Company Date Fm sws into indoor air during pradu usage. ore informolion,risii ul.cam/gg. The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). www.knaufinsulation.us Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-4434 ext.8300 FAX:(317)398-3675 ©2015 Knauf Insulation,Inc. Building and Construction Services C8 S C PA COUNTY FLORIDA Property Address: Unit M Permit#: Testing Company Name: Test Date: Tester Name: Tester Cert M Contact Phone: 402�1.2 Testing. Building envelope air tightness shall te demonstrated 6w Section 402/il2 The building or dwelling unit shall be tested and verifled as having an air leakage rate ofnot exceeding 5 air changes per hour. Testing shall be conducted with ublower door atupressure ofO2 inches mg. (50}ascals). As required by the Building Official, testing shall be conducted byuo approved third party.Awritten report of the results o[the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior to Certificate of Occupancy ioouu000. Toxbug obuD be performed at any time after czcoduu of all scheduled penetrations oC the building thermal envelope. During testing:(check bmverify condition met) U Exterior windows and doom, fireplace and stove doom shall be closed, but not sealed, beyond the intended weather-stripping or other 91 Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration C8Interior doors,if installed at the time uf the test,shall beopen ` Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed Heating and cooling systems, if installed at the time of the test,shall be turned off Supply and return registers,if installed at the time of the test,shall be fully open //°��� � Vu 8ui|{�in(� volunne �t ) = '~=^�^^ ^� Qso Airflow at 50 Posoo| (CFM) = (U ACHm Air changes per hour ot50 Pascal � Qxox 60+' Vb ~~ /&CHxo (I0ACHminimum) PaoJW F[� El Outside Air mechanically introduced to space (less than 3.0ACH) /heraby certify that the above envelope leakage performance results demonstrate compliance with Florida Enerp Code requirements in accordancewith SectionR4Q%4.2.2.