HomeMy WebLinkAbout18-20570 CITY OF ZEPHYRHILLS
5335-STH STREET
(813)750-0020 20570
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT JNFORMATION LOCATION INFORMATION
Permit#:20570 Issued: 12/12/2018 Address: 6878 WAGON TRAIL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 266,079.30 Total Fees: 14,291.69 Subdivision: SILVERADO
Amount Paid: 14,291.69 Date Paid: 12/12/2018 Parcel Number: 05-26-21-0100-0.1100-0140
CONTRACTOR INFORMATION OWNER INFORMATION
Name: DR HORTON INC Name: DR HORTON INC
Addr: 12602 TELECOM DR Address: 12602 TELECOM DR
TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935
Phone: Lic: Phone: 813-549-1968
Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT
APPLICATION FEES
BUILDING FEE 1,477.49 ELECTRICAL FEE 309.38 PLUMBING FEE 206.25
MECHANICAL FEE 144.38 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
C,
Inspections Re uire
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFIjFA
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
INSTR#2018189668 OR BK 9815 PG 2078 page 1 of 1
11/08/2018 02:47 PM Rcpt:2004877 Rec:10.00 DS:0.00 IT:0.00
pauCa S. O'Nei4 A.D., Pasco County CCerk&comytroffer
Permit No. Parcel!IDNo 05-
NOTICE OF COMMENCEMENT
State of Florida county of Pasco
THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement
1 Description of Property: Parcel Identification No. L-,o+ OCA< t 1i Si 1 y-e-rafk U P va:sp- I
Street Address: 6!E5-7<9 V'f-CL n I(—(:2t Leo h N y-h i I I S, FL
I -
2- General Description of Improvement New Single Family Residence
3. Owner Information or Lessee information if the Lessee contracted for the improvement
D.R. Horton, Inc
Name
12609 Tale-rom Drlyt- Tampa 33637 1=1
Address city state
Interest in Property: Fee Sim ple
Name of Fee Simple Titleholder.
(if different from Owner listed above)
Address city State
4. Contractor . D.R. Horton. Inc
Name
12602 Telecom Drive Tampa 33637 FL
Address city State
Contractors Telephone No.:
5. surety: NIA
Name
Address city State
Amount of Bond: $ N/A Telephone No.:
6. Lender. N/A
Name
Address city state
Lenders Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)M,Florida Statutes:
David Gude
Name
12602 Telecom Drive Tampa 33637 FL
Address city State
Telephone Number of Designated Person: _ 813-740-9720
8. In addition to himself,the owner designates NIA Of
to receive a copy of the Lienor's Notice as provided In Section 713.13(l)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF,COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the foregoing commencement and that the facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OF PASCO ja,
Q-nature of Owner or Lessee,or Owners or Lessee's Authorized
Officer/Director/Partner/Manager
Assistant Secretary/D.R. Horton, Inc
Signatory's Title/Office
-1-11n Novtm The foregoing instrument was acknowledged before me this day of— NLV_�20 O&y_
as Assistant SecretaI3 attorney in fact)for
(type of authority,e.g.,officer,trustee,a
D.R. Horton, Inc (name of party on behalf ofwh i I.mentwas executed).
Personally Known D4 OR Produced IdentfficationEl Notary Signatur
Type of Identification Produced Name(Print)
,0k
0ANA ANNE NAGHTIN
Notary
P, 1,c_ t 0
Notary Public-State of Florida
Commission #GG 010660
-W�-
.0
MY COMm E Expires Jul 12.2020
wpdata/bcsinoticecommencement_pc053048
t DR Horton-6878 Wagon Trail Si-2,362 sq ft
Column
SQ. FEET PRICE n ' Z
MAIN OR LIVING: 2,362 $ 112.65 �Y
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 266,079.30
FEE SHEET $ 1,375.00
ADDRESS $ 30.00
DRIVEWAYJ $ 45.00
BUILDING: $ 1,477.50
ELECTRICAL: $ 309.38
PLUMBING: $ 206.25
MECHANICAL: $ 144.38
SUB-TOTAL $ 2,137.50
TOTAL $ 2,137.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
I
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,690.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,291.69
PASCO COUNTY, FLORIDA
Permit No. . Zo 5Z0
Date Permitted /2- z-
Builder Name/Owner Name Control#'
County Parcel No. 0 5 2fP�2- b 00-61100-0 1110 SubDiv: Uerah _
Address/Location 0_ 4 c5T—
�
ClassificationlType of Use le Vtn, 13(,Z
TRANSPORTATION IMPACT F E Rate: Sq.Ft Unit: 2r3 Z
Exempt ❑Yes ❑ No ow Determined
Impact Fee Amount $. Z,6b Zone No. TAM
SCHOOL IMPACT FEE
Account (056) Single-Faml y Detached House Amount $ 7 , (4��
(057) Mobile Hoff e
(058) Other Resicential
123) Collection epee
Exempt �Yes ❑No How Determined
PARKS AND RECREATION F E
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 7647.5k
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total Exempt E] Yes E] No How Determined Total Amount-- �
&
RESOURCEFEE ERU
TOTAL AMOUNT
Prepared By 2i-- Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not I mply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owns on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
05-26-21-0100-01100-0140 1 Pasco County Property Appraiser Page 1 of 1
Zo -76
Data Current as Of: Weekly Archive - Saturday, December 8, 2018
Parcel ID 05-26-21-0100-01100-0140 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DR HORTON INC Ag Land $0
12602 TELECOM DR Land $2,286
TEMPLE TERRACE FL 33637-0935 Building $0
Physical Address Extra Features $0
6878 WAGON TRAIL STREET
ZEPHYRHILLS, FL 33541 Just Value $2,286
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,286
SILVERADO RANCH SUBDIVISION
PHASES 7, 9B, 11A AND 116
PB 77 PG 079 Taxable Value $2,286
BLOCK 11
Jurisdiction
City of Zephyrhills
_ ___ Land Detail (Card: 001 of 001)
Line _ _ DescriptionZo ing jUnits T_ ype Orice —Condition Value
1 duse 0100 SFR j MPUD 1 5,715.00 SF $0.40 I 1.00 $2,286
Additional Land Info_r_mation
Acres 0.13 ,Tax Area 30SI Code -- Residential Code NEWSUBB
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001) _
Line _ __Description jYear --�— _-Units — -_ 1Value -----
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/YearBook/Page Type 'D_OR Code Conditio_mount _
11/2018 9813 / 332Q__j Warranty Deed _ 05 Vacant Multi-Parcel Sale
05/2017 f 9535 / 0546 Certificate of Title 05 Vacant Multi-Parcel Sale
11/2016 9462 0384 ,Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale
http://search.pascopa.com/parcel.aspx?parcel=2126050100011000140 12/11/2018
Lennar Homes 6878 Wagon Trail St-2,362 sq ft
Column
SQ.FEET PRICE
MAIN OR LIVING: 2,362 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 266,079.30
FEE SHEET $ 1,375.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,482.50
ELECTRICAL: $ 309.38
PLUMBING: $ 206.25
MECHANICAL: $ 144.38
SUB-TOTAL $ 2,142.50
Public Fee 1%
TOTAL $ 2,142.50
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,695.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,296.69
Single Family Dwelling
Plan Review Comments
1: F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C:
I. Compaction test required if.24 or.more of fill dirt is brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru-the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All-pro''erty.markers shall be uncovered and marked at time of first inspection.
8. All A.D.A. requirements shall be met.
9. No electric,plumbing,mechanical; or framing shall be covered without an,inspection and
approval first.
10. All Garages shall comply with section R302.6 of the F.B.C..(Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303.4-of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M13.08.1
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are to be installed in accordance with R313.1 ofthe F.B.C.
16. All glazing requirements are to be in accordance with R308.4-of the F.B.C.
17. All means of egress are to,be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in-new construction that uses fossil.-burning heating
or appliances'or an attached garage. They shall be installed in accordance with the F.B.C.
21. All plumbing, mechanical, and electrical shall be separate from unit to.unit. This:includes all
underground plumbing and electric:
22. All 2016 N.E.O. Codes will be enforced.
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.C.
24.. In accordance with the Land Development Code, lots shall be sodded_ before final at least 10
feet around the structure.
25. Blower door test and blown in insulation card shall be provided before C.O.
26.A copy of the energy cacls shall be with permit at all times
27. Cony of final insulation report shall be.:provided with.permit before.rinaL
28. No fence,.poolor screen enclosure is.issued with this permit
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code Wh Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016)
813-780-0020 City of ZephyrhillS Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting -
Owner's Name C ,- c I-, <: Owner Phone Number ��d f�
Owner's Address �, ` `� 'r' �'"r T�/y,fpJu^ �' Owner Phone Number
Fee Simple Titleholder Name ,� —� Owner Phone Number —�
Fee Simple Titleholder Address /
JOB ADDRESSE a �1 1 !'G i � " LOT#
SUBDIVISION L r=F' PARCEL lD# 1`' �n (� �� ' 01f 6 y f
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN DEMOLISH .
INSTALL. REPAIR
PROPOSED USE �''� SFR 0 COMM �� _ OTHER
TYPE OF CO,NSTRUCTiON . �� BLOCK : FRAME. STEEL 0
DESCRIPTION OF WORK rlel:,o -VI
BUILDING SiZE SO FOOTAGE �'� HEIGHT [�
'.r'x-e-s-Y-¢'-a'i-t-�-•a-P'-r'�-i-R"r-�-c-�r~�-�-g-¢-'a��-�^a-e->a-t-v�- r-a.es°'i n�-e�'-C���a�°»�o��e-��ra-+r�a�•-
=BUILDING $ L �0= VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $. AMP SERVICE 0 PROGRESS ENERGY W.R.E.C.
=PLUMBING $
OMECHANiCAL $ �� VALUATION OF MECHANICAL INSTALLATION
=GAS ED/ ROOFING SPECIALTY �_i OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES ' NO
-�i-➢-➢-i-8--➢-➢-➢-➢•-G-�'-@--9-•�•-➢-y-€-➢-E-�-�•-8-➢�,°-➢--E-�-ir-➢-,"rs`- "�Ilt�:•�-�"�_�" ➢�°�➢�r°�°e� i��°�°�i ice^-6�5��P�
--BUILDER �1 ,,/ COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address �o� ��vl l��r'<in License#
1=LECTRiCiA(V ,! --- COMPANYG�,^d'FC�°n�. a?k? ('
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
�'d. '�:>`= �O" ram- License#
Address �� f?' --
PLUMBER COMPANY 1' "!' � •fi �� � � � �
.SIGNATURE � T_! REGISTERED Y I N I FEE CURREN Y I N
Addresser License
MECHANICAL r r COMPANY
SIGNATURE f«^ "�C/� �"' _'`_"-REGISTERED Y`/ N FEE CURREN Y/N
Address ✓Hai�ri,�r" �. f*uca,a ,,.u! f�:r j License# CAL-�
OTHER,• -_ -�_.._ COMPANY .�� �t /.v vl c, � _4 J)..' f
SIGNATURE' REGISTERED Y/ N FEE CURREN LY/N
Address !� l{ !" / n License# "-
➢ l.➢ � 6 ➢ ➢ ➢ i' i1 ➢ ➢ ➢ ➢ i1 :I ➢ ➢ ➢ i ➢ i ➢ ➢ ➢ ➢ ➢ ➢ Il ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ ➢ Il ➢ 18p ➢ ➢ Il ➢ ➢ ➢ @ ➢ ii ➢ ➢ ➢ ➢ ➢ ➢ ➢ B ➢ ➢ ➢ i .
RESIDENTIAL Attach (2) Plot Plar:a; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)%-orking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit.Fence installed,
Sanitary Facilities&; i dumpster;Site Work'Permit for subdivisions/large projects
COMMERCIAL Attach(2).compietl: Sets Of Building Plans plus a Life Safety Page; (1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten (10)i. )rking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities 1 dumpster.Site Work Permit for all new projects.Ail commercial requirements must meet compliance
SIGN PERMIT Attach (2)sets of F,igineered Plans.
"PROPERTY•Si.,:tVEY required for all NEW construction,
,-➢-.6.-b...i-.d-.➢-�i-.➢--�-�-6-➢-➢--➢.-.B.:�i.,:.�.➢-$-�,-➢-�➢vi,.ib.-$.-ge.C-@-4•-$-pe.&�8,.s4-@�9-G�8- i> ➢- E4=C�g�Il-.m19�.m➢.�➢�.u..�rs°,t�B®5�
"Directions:
Fill out application completely. ,
Owner§L Contractor sign back of upiication,notarized
if over,$2500,a Notice of Comnsancement is required. (A/C upgrades over$7500)
�* Agent(for the contractor) or PO of Attorney(for the owner)would be someone with notarized letter from owner;-authbrizirig.same"
OVER THE COUNTER PERMITTING {copy Of contract required}
Reroofs•if shingles Sewers !Service Upgrades A/C Fences(Plot/Survey(Footage)
Driveways-Not over Counter if on public roadways..needs ROW
`
'
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions".
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
' applicable deed restrictions. �
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired e contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local negukationa. lf:the '
contractor is not-licensed an required by |aw, both the owner and contractor may be cited for u nn|ademe�anor violation
under state law.' If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,.they are advised to contact the Pasco County Building Inspection Division—Licensing Section et727-847-
8009. Furthermore, if the owner has hired s contractor or onntractora, he is advised to have the contractor(s) aign
portions of the "contractor 8\oCK' of this application for which they will be responsible. If you, ea the owner,sign as th�
contractor, thad.mey be an indication that he is not properly licensed and is not entitled to permitting privileges.in Pasco
County. '
TRANSPORTATION lD0P/\CT7QT|LlT|ES IMPACT AND RESOURCE RECOVERY FEES.: The undersigned understands
that Transportation,\mpa:ct Fees and Recourse Recovery Fees may apply to the constructionn-of new bui|dings, change of '
use in existing buildings, or expansion of existing_buildings, as specified in Pasco County Ordinance number 89-07 and
90 0 as amended. The undersigned also understands, that such foes' as may be due, will be identified at the time of
i! i h i� fu�h�r understood that Transportation Impact Fees and Resource Recovery F�as must be paid prior to
porm�ng�
receiving a "certificate of occupancy" or final power release. ,|fthe project does not involve u certificate of occupancy or
final power ra|eaae, the fees must be paid prior to permit issuance. Furthermore, if paaoo�Cou nty Water/Sewer Impact
fees are due,they must be paid prior to permit issuance )n accordance vv�happlicable Pasco C|oVntyordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of Work is $2.500.00 or more. |
cerbfv that |, the applicant, have been provided with a copy of the "Florida Construction- Lien Law—Homeowner's:.Pro 'ution Guide" prepared by the Florida Department of Agriculture-and Consumer Affairs. If the applicant is someone
other than the-"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the^ovvner" prior to oVnnmanoernenL
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regul
ating oonetruot|on, zoning and {and development. Application is
hereby made to obtain a permit to do work and installation as indicated. \ certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes; zoning regulations, and land development reQu\o±ions in the jurisdiction. | also
oe�\fv that | understnnd 1ha1the regulations ofothe� government agencies may apply to the intended work, and that it is.
�myr^aponaibi|\tytoidentUvvvho1eodons \ musttaketobeinoompUance. Such agencies include but are not Unn�edto:
Department of' Environmental P rote otion-Cypreoo Boyheado, Wetland Areas and Environmentally .Sensitive
Lands,Water/Wastewater Treatment.
Southwest Florida Water Management District-Wells, Cypress- Bayhaada. Wetland Areas. Altering
Watercourses. .
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. �
Department of Health @ Rehabilitative Sen/ivaa/Environmen¢o| Health Unit-Wells, Wastewater Traatment.�
Septic Tanks. _
- US-Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runwaye.
| understand that the following restrictions apply to the use nffill:
' Use of fill iu not allowed in Flood Zone"V" unless expressly permitted.
If the f||| material is to be used in Flood Zone ^A., it is understood that u drainage plan addressing a
' ''compensating volume" will be submitted at time of permitting which in prepared by a professional,engineer
licensed by the State of Florida. �
- If the fill nnatuha| is to be used in Flood Zone "K in connection with o permitted building using stern vva\\
construction, | certify that fill wIll be used only to fill the area within the ntannvvaU.
M fill material is to be used in any area, | nertifk that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be nMad forvioluUng
' the conditions of the.building permit issued under the attached permit appUcatinn, for lots |eaa than one U\
' acre which are elevated by fill, an engineered drainage plan is raquir6d.
If | am the AGENT FOR THE OWNER, | promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction.' \ understand that a separate permit may be.required for electrical xvork,
p|umbing, signs` vveUs, pools, air oondidoning, gan, or other installations not specifically included in the application. A
permit issued �ha|| be nnoe1h/ed to be a license to proceed with-the work and not as authority to violate, cancel, altor, or
set aside any provisions of the technical codes, nor shall issuanbe .of a permit prevent the Building Official from thereafter
requiring a correct!?n of errors-in p|ans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit \sauance, or if work authorized by
the permit is suspended or abandoned for a period,ofsix (G) months after the time the Work is nonnmenned. An extension
may be requested, in writing, from the Building Official for u period not to exceed ninety (AO) days' and will demonotrete '
` juntifiab|e'nause for the extension. -If work ceases for ninety (QO) consecutive days,the job is considered abandoned. '
WARNING
TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF C[}88K0ENCB&EMT MAY RESULT IN YOUR,
PAYING TWICE FOR IMPROVEMENTS TQ YOUR PROPERTY. |F YOU INTEND TO OBTAIN FlNAN[i0G, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT:
Fuvn/u*:on*/ (-.S.n/.om
OWNER OR AGENT cnwTRacTo
Subs """=^'"""= d"��" ~ p" �'""'=v "=="="this
by by
vvx4nbe
pemonaly known to meo,hao/haxe,pmduuod Who���p�mnn��kno�nx,�o o,xao�a,o produced
as Identification. ` ^
'
Notary Public Notary
'
Public. `
' Commission No. Commission No
Nam
.
___N—_' ,,-�.,--__ _--m,-_ `
Commission #
on Expires
MY Commissi
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 14, BLOCK 11, SILVERADO RANCH SUBDIVISION PHASES 7, 96, 11A & 11B
NOT YET RECORDED IN PLAT BOOK PAGE(S) OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
Curve Table
Curve # Length Radius Delta Chard Bearing Chard
C1 19.53- 30.00- 37-17-27- N15-58-54-E 19.18-
Line Table
Line # Direction Length
Ll NO2.39-49-W .31,83-
1" = 30'
GRAPHIC SCALE
0 is 30
\7
A, 15-
rj *C�:
70,.0
f1E 108.8 7
N87-20 11
LL
22 5- D&AE 2 1 7.3'—
51.7'
rn
T� 'D il" , f—
o
S II
C: 4. ;U
A I — ::I -- �1'
;0 m�to 0. 0 0
Ct --i
PT Aw.0 --i
z >0
> C5 11 iq �, 0
4.7' 0 2 1 0
rn
m 0 :1
m C) �0 A
W >0
to Ln
Z ;D p
>
I" rq Lo 'Rz i9c:1
< 0 z
;. Cy
59.67'
I.........
> Z %
10> "D 59.7' 27.3y
;a -F co-6
C! r>qg (p 5' D&AE
%U m Il iN__ s
m ;a t115.00'
0 S N -20`11 ;E S87-20'1 1 W
n 30.00
:e m
>
lot I LOT 13
PC BLOCK 11 ON LOT CALCULATIONS
LOT = 5,715 SQ. FT.
LIVING AREA = 1,828 SQ. FT.
GARAGE = 430 So. FT.
ENTRY = 16 SQ. FT.
LANAI = 88 SQ. FT.
PATIO = 0 SQ. FT.
DRIVEWAY = 465 SO. FT.
A/C PAD = 12 SQ. FT,
WALKWAY = 28 SO. FT.
IMPERVIOUS = 50%
B-B-HOKRJN* — 2857 SQ. FT.
SOD = 2,848 SQ. FT.
OFF LOT CALCULATIONS
RIGHT OF WAY = 979 SO. FT.
BUILDING SETBACKS DRIVE APRON = 228 SO. FT.
PUBLIC S/W = 268 SQ. FT.
FRONT: 22' SOD = 483 SO. FT.
REAR: 15' TOTALS
SIDE: 5- (50- LOTS) AREA = 6,694 SQ. FT.
7.5- (55- & 60- WIDTH LOTS) DRIVEWAY = 693 SO. FT.
SIDE STREET. 15' SIDEWALK = 296 SO. FT.
NOTES: LEGEND: SOD = 3,331 SO. FT.
1. ELEVATIONS SHOWN ARE PER LOT GRADING
PLANS PROVIDED BY THE CLIENT. • BUILDING SETBACK LINE PI POINT OF INTERSECTION
2. ELEVATIONS ARE BASED ON NAVD 1988 PC POINT OF CURVATURE
DATUM. CENTERLINE PT POINT OF TANGENCY
3. FOR ALL LOTS WHERE SIDE SETBACKS ARE RIGHT OF WAY LINE RP RADIUS POINT
LESS THAN 7.5', A MINIMUM 5' WIDE PRC PONT OF REVERSE CURVATURE
DRAINAGE AND ACCESS EASEMENT WILL BE PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE
TYP TYPICAL
LOCATED ON ALL SIDE LOT LINES, PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
P PLAT EEO CONCRETE (P) PER PLAT
(C) CALCULATED
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/C AIR CONDITIONER PGB S PAGES BOOK
THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND S/W SIDEWALK SO. FT. SQUARE FEET
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK F.E.M.A, FEDERAL EMERGENCY MANAGEMENT AGENCY
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.I.R.M. FLOOD INSURANCE RATE MAP
AND IS FOR INFORMATIONAL PURPOSES ONLY. NAVD NORTH AMERICAN VERTICAL DATUM
NGVD NATIONAL GEODETIC VERTICAL DATUM
UE DRAINAGE&UTILITY
THIS IS NOT A SURVEY PD D&E PRIVATE DRAINAGE EASEMENT EASEMENT
THIS IS A PLOT PLAN ONLY PUE WC PUBLIC UTILITY EASEMENT
ASS WETLAND CONSERVATION AREA SETBACK
FLOODNOTE; SURVEYOR NOTES:
'HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F. 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DATED SEPTEMBER 26, 2014. AND FOUND THE SUBJECT PROPERTY
APPEARS TO LIE IN ZONE-X'. AREAS DETERMINED TO BE OUTSIDE THE LAND SHOWN HEREON FOR EASEMENTS. RIGHT
WAY. RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO OF
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE MAY AFFECT THE TITLE OR USE OF THE LAND.
LOCAL F.E.M.A. AGENT FOR VERIFICATION.
2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
BEARING BASIS: -- LOCATED EXCEPT AS SHOWN.
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC
TRAIL STREET BEING NO2-39-49-W. PER PLAT, ELECTRONIC SIGNATURE AND THE AUTHENTIC
REVISED: ]NA F= FR I ELECTRONIC SEAL OF A FLORIDA LICENSED
(FIELD DATE:) SURVEYOR AND MAPPER.
SCALE: 30 FEET U R V E- I N 0 Digitally signed byJim Soleman
ON:cn=Jim Boleman,
o=Ame Ican Surveying&
ja APPING INC. r
APPROVED BY;
in Lan@asmcorporatex tpalpf7b'oole
180820 LOT 14, CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 Y%;g-,:
3191 MAGUIRE BOULEVARD, SUITE 200 FOR
BLOCK 11 --0-m C�us-' THE
JOB NO.
ORLANDO, FLORIDA 32803 Date:2018.10.30 08:31:05-04'00' FIRM
DRAWN BY: DEB (407) 426-7979
PLOT PLAN 10/29/18 RMB WWW.AMERICANSURVEYINGANDMAPPING.com JAMES W. BOLEMAN PSM# 6455 DATE
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional,Regulation - Residential.Performance Method
Project Name: Cali 1828 Elev D Builder Name: DRH Expreas Ho'�omps
Street: Wa c,o" k r-c. Permit Office: C4V or 2e
City,State,Zip: Zephyrhil%,FL, 3-35441 Permit Number: 7,6-570 US
Owner: S L V Jurisdiction:
Design Location: FL,Tampa 144 County: Pasdfo(tFlo(roid'a0li mate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 scift.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=41 1404.00 ft2
b.Frame-Wood,Adjacent R=1 1.0 306.22 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1828.0 scift.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area above grade(W) 1828 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(I 66.5 scift.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356
a. U-Factor: Dbl,U=0.34 126.50 ft2
SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency
b. U-Factor: Dbl,U=0.55 40.00 ft2 a.Central Unit 28.6 SEER:14.00
SHGC: SHGC=0.34
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.722 ft. 14.:Hot water systems
Area Weighted Average SHGC: 0.317 a.Electric Cap:50 gallons
8. Floor Types (1828.0 scift.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.25 PASS
Total Baseline Loads: 61.29
1 hereby certify that the plans and specifications covered by Review of the plans and v 01113 S7,4
this calculation are in compliance with the Florida Energy specifications covered by this
F=
Code. calculation indicates compliance '9'
with the Florida Energy Code.
PREPARED BY: Lgc-". Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 646
I hereby certify that this building,as designed,is in compliance Florida Statutes. Q01)WT,-TV
with the Florida Energy Code.
OWNER/AGENT. BUILDING OFFICIAL:
-
DATE: V DATE.,
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualities as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 On for whole house.
11/6/2018 3:32 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 4
,
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes
Street: (p$`f$ L,-'CaclOY1 lrC«� �� " Permit Office:
City,State,Zip: Zephyrhills,FL, 3354 J Permit Number:
Owner: S`-V Jurisdiction:
Design Location: FL,Tampa 144 I I County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2
b.Frame-Wood,Adjacent R=11.0 306.22 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1828.0 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356
a. U-Factor: Dbl,U=0.34 126.50 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.25 PASS
Total Baseline Loads: 61.29
hereby certify that the plans and specifications covered by Review of the plans and JAB 87.
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. ti rtrrr ''( °: ? ��",,�0
PREPARED BY: L'M4-,Q.,.:� Before construction is completed •+
,A a"...._.._ .
DATE: 11-9-11 this building will be inspected for
compliance with Section 553.908 * a
hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Code. �oD y�1 �
OWNER/AGENT•-� C, r �''�""� BUILDI F ICI
DATE: H , 1� ( � DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 On for whole house.
1 1/6/201 8 3:32 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4
y
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Cali 1828 Elev D Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 1828 Lot# 14/11
Owner Name: Total Stories: 1 Block/Subdivision: Silverado
#of Units: 1 Worst Case: No PlatBook: Phase 7
Builder Name: DRH Express Homes Rotate Angle: 270 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Garage R Face W
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
V/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocki 1828 15848.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ft2 ---- 0 0.25 0.75
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V/ # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2044 ft2 0 ft2 Dark 0.92 No 0.9 No 0 26.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1828 ft2 Y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1828 ft2 0.11 Wood
11/6/2018 3:32 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
Omt To WAT TVPP1 N=>W Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 164.7 ftz 0 0.6 0
2 W=>S Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 ftz 0 0.6 0
3 S=>E Exterior Concrete Block-Int Insul Main 4.0999 39 8 8 8 343.8 ftz 0 0.6 0
4 E=>N Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ftz 0 0.6 0
5 N=>W Garage Frame-Wood Main 11 20 0 8 8 173.3 ftz 0.23 0.01 0
6 W=>S Garage Frame-Wood Main 11 15 4 8 8 132.9 ftz 0.23 0.01 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>W Insulated Main None .4 3 6 8 20 ftz
2 N=>W Wood Main None .46 2 8 6 8 17.8 ftz
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ftz 1 ft 0 in 4 ft 1 in None Exterior 5
2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ftz 3 ft 8 in 0 ft 0 in None Exterior 5
3 W=>S 2 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ftz 1 ft 0 in 0 ft 9 in None Exterior 5
4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ftz 1 ft 0 in 0 ft 9 in None Exterior 5
5 S=>E 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ftz 8 ft 0 in 0 ft 8 in None Exterior 5
6 E=>N 4 Vinyl Low-E Double Yes 0.34 0.31 N 15.5 ftz 1 ft 0 in 0 ft 9 in None Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 430.0128 ftz 430.0128 ftz 46.6 ft 8.67 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000386 1849 101.51 190.9 .2941 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.2 28.6 kBtu/hr 1 sys#1
1 1/6/201 8 3:32 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler. TOT OUT QN RLF Heat Cool
1 Attic 6 356 ftz Main 40 ftz Proposed Qn Main ---cfm 109.7 cfm 0.06 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar r 1 Apr May Jun Jul AugSe Oct Nov Dec
Heatin Jan f X}Feb Mar r 1 Apr f May 4 Jun 4 Jul f Auf Sep Oct Nov Dec
Vent in Jan Ill Feb Mar [X]Apr [ May l Jun l Jul [ Aug [ Se Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78, 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default 8 Ibs/s .ft. 0 ftz Oft 0.3 Main
Name: Test Rater Signature:
Rating Compant: Test Rater Date:
11/6/2018 3:32 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or,addition 1. New(From Plans) 12. Ducts,location&insulation level
a) Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13.Cooling system: Capacity 28.6
a)Split system SEER
5. Is this a worst case? (yes/no) 5. No b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 1828 d) Room unit/PTAC EER
e)Other 14.0
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.390
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.317 14. Heating system: Capacity 28.6
c)Area 7c. 166.5 a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace,natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 8.20
9. Floor type,insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood, raised(R-value) 9b. 15.Water heating system
c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95
b) Gas fired,natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 11.0
2.Masonry(Insulation R-value) 10132.
16.HVAC credits claimed(Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11 a. 30.0 b)Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11c. d) Multizone cooling credit
d) Radiant barrier installed 11d. Yes e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation,if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded) in this home before final inspection.Otherwise,a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: < < (3
Address of New Home: (o rl lr'a, �T City/FL Zip: Zephvrhills, FL J3�4
11/6/2018 3:32:53 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: Permit Number:
Zephyrhills, FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
✓ SECTION R401 GENERAL
❑ R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveloW building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Instal lation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required
by the code official,an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either
individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i)or
an approved third party.A written report of the results of the test shall be signed by the parry conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures.
3.Interior doors,if installed at the time of the test,shall be open.
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
❑ R402.4.2 Fireplaces. New woad-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where
using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the
fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907.
R402.4.3 Fenestration air IeakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
11/6/2018 3:33 PM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to
open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2,where the walls,floors and ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential.
❑R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 controls. SECTION R403 SYSTEMS
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or
(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(1), Florida Statutes,to be"substantially leak free"in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
1. Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the system,including the
manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test.
2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the
entire system,including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 550F(13°C)shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that
caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause
degradation of the material.Adhesive tape shall not be permitted.
❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return
❑ pipe shall be.a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
11/6/2018 3:33 PM EnergyGauge®USA -FBC 6th Edition(2017)Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies(Mandatory).
R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature
setting range shall be from 100°F to 140DF(38°C to 60oC).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of
combustion types of service water-heating systems to be turned off.
R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar
water-heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation
including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical
ventilation system,fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable
Indoor Air Quality,shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10
otherwise.
R403.7 Heating and cooling equipment(Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that
affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMUIV
(CFM) (CFM/WATT) (CFM)
Range hoods Any 2.8 cfm/watt Any
In-line fan Any 2.8 cfm/watt Any
Bathroom,utility room 10 1.4 cfm/watt <90
Bathroom,utility room 90 2.8 cfm/watt Any
For SI:1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916
1 1/6/201 8 3:33 PM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's
expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded
performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4.8°C).
❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an
integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation
of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the
power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots.
R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered
energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required.
R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
11/6/2018 3:33 PM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas(Mandatorgohe energy consumption of electric-powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps.
Exception:Low-voltage lighting.
R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights.
11/6/2018 3:33 PM EnergyGauge®USA -FBC 6th Edition(2017) Compliant Software Page 5 of 5
2017-AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills,FL, Permit Number: Y
Owner: Jurisdiction: W
Design Location: FL,Tampa U
COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall
The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material.
requirements Breaks or joints in the air barrier shall be sealed.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier.
Access openings,drop down stairs or knee wall doors to
unconditioned attics aces shall be sealed.
Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity
sealed. with a material having a thermal resistance of R-3
Knee walls shall be sealed. per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows,skylights The space between window/doorjambs and framing,and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to
(including insulation. maintain permanent contact with the underside of
above-garage subfloor decking,or floor framing cavity insulation
and cantilevered shall be permitted to be in contact with the top side
floors) of sheathing,or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation
a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace
Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit,or narrow
Narrow cavities cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac as.
Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building
shall be sealed to the drywall. thermal envelope shall be air tight and IC rated.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls,or insulation that on
installation readily conforms to available space shall
Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the showers and tubs. be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air-sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub-floor or drywall.
Concealed When required to be sealed,concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a.In addition,inspection of log walls shall be in accordance with the provisions of ICC-400.
1 1/6/201 8 3:33 PM EnergyGauge®USA FBC 6th Edition(2017)Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit#:
Job Information
Builder: DRH Express Homes Community: Lot: 14/11
Address:
City: Zephyrhills State: FL Zip:
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
O PRESCRIPTIVE METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g.(50 Pascals)in Climate Zones 1 and 2.
0 PERFORMANCE or ERI METHOD-The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50)value,as shown on Form R405-2017(Performance)or R406-2017(ERI),section labeled as infiltration,sub-section ACH50.
ACH(50)specified on Form R405-2017-Energy Calc(Performance)or R406-2017(ER!): 7.000
x 60 _ 15849 = Method for calculating building volume:
CFM(50) Building Volume ACH(50) 0 Retrieved from architectural plans
1-1
PASS •Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration
control measures.
2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control
measures.
3.Interior doors,if installed at the time of the test,shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5.Heating and cooling systems,if installed at the time of the test,shall be turned off.
6.Supply and return registers,if installed at the time of the test,shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
11/6/2018 3:33:11 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Duct Leakage Test Report
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction- Permit#:
Job information
Builder: DRH Express Homes Community: Lot: 14/11
Address:
City: Zephyrhills State: FL Zip:
Duct Leakage Test Result s 0 Prescriptive Method Q Performance/ERI Method
System 1 cfm25 0 prescriptive Method cfm25(Total)
System 2 cfm25 To qualify as,°substantially leak free"On Total must be less than or
equal to 0.04 if air handler unit is installed. If air handler unit is not
System 3 cfm25 installed,On Total must be less than or equal to 0.03.This testing
method meets the requirements in accordance with Section R403.3.3.
Sum of any cfm25 Is the air handler unit.installed during testing?❑YES(sa°.) El NO{50
Total of all cfm25 0 performance/ERI Method cfm25(Out or Total)
To qualify using this method,On must not be greater than the
= 1828 = Qn proposed duct leakage On specified on Form R405-2017 or R406=2017
Total of all Total Conditioned
systems Square Footage Leakage Type selected on Form Qn specified on Form R405-201 7
R405=20 f 7(EnergyCalc)or R406-2017 (EnergyCalc)or R406-2017
PASS FAI L Proposed C In o.os,
Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section
553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i), Florida Statutes.
Testing Company.,
Company Name: Phone:
hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the
selected compliance path as stated above, either the Prescriptive Method or Performance Method.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification#: Issuing Authority:
1 1/6/201 8 3:33:17 PM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
+� wrightsoft®
Manual S Compliance Report Date:
Entire House By:
Progressive Air Systems, Inc Plan: Cali 1828
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Project • •
For: DR Horton
Lot 14 Blk 11 Silverado, Zephyrhills, FL
Cooling, Equipment
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 20893 Btuh Entering coil DB: 75.4°F
Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB: 62.7°F
Indoor design DB: 75.0°F Total gain: 23859 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB030+FB4CNP030
Actual airflow: 1000 cfm
Sensible capacity: 23272 Btuh 111%of load
Latent capacity: 3908 Btuh 132%of load
Total capacity: 27180 Btuh 114%of load SHR: 86%
Heating 'equipment
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB030+FB4CNP030
Actual airflow: 1000 cfm
Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: . Elec strip
Manufacturer: Model:
Actual airflow: 1000 cfm
Output capacity: 6.6 kW 107%of load Temp. rise: 20 OF
Meets are all requirements of ACCA Manual S.
4� wri htsoft° 2018-Nov-0615:33:26
�� 9 Right-Suite®Universal 2017 17.0.21 RSU25554..ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 House Front faces: W Page 1
Load Short Form Job:
wrightsoft Date:
Entire House By:
Progressive Air Systems, Inc Plan: Cali 1828
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Projecte •
For: DR Horton
Lot 14 Blk 11 Silverado, Zephyrhills, FL
D- • • •
Htg Clg Infiltration
Outside db(OF) 40 91 Method Simplified
Inside db(OF) 70 75 Construction quality Semi-tight
Design TD (OF) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/lb) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NBO30 Cond CH14NBO30
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh Cab 47OF Latent cooling 7500 Btuh
Temperature rise 27 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=32 OF
Backup:
Input= 7 kW Output= 22477 Btuh 100 AFUE
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
M bed 194 3196 3104 151 149
living room 270 2891 3627 137 174
kitchen/dining 349 4292 5088 203 244
bed3 155 1420 1098 67 53
bath2 55 604 278 29 13
bed2 168 . 3411 3268 162 156
we 21 24 35 1 2
M bath 114 1276 652 60 31
M wic 66 77 112 4 5
laundry 39 45 668 2 32
bed4/den opt 169 1866 1306 88 63
A/C closet 19 181 114 9 5
foyer 200 1817 1542 86 74
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoftq 2018-Nov-0615:33:26
9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=W8 House Front faces: W
Entire House d 1820 21100 20893 1000 1000
Other equip loads 0 0
Equip. @ 1.00 RSM 20893
Latent cooling 2966
TOTALS 1820 21100 23859 1000 1000
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
.L wri htsoft, 2018-Nov-0615:33:26
g Right-Suite®Universal 2017 17.0.21 RSU25554...ightsoft Files\Express homes\Cali 4EBB 1828.rup Calc=MJ8 House Front faces: W Page 2
Project Summary Date:
wrightsoft- Entire House By:
Progressive Air Systems, Inc Plan: Cali 1828
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
■ • • •
For: DR Horton
Lot 14 Blk 11 Silverado, Zephyrhills, FL
Notes:
Design Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 40 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 30 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17539 Btuh, Structure 16295 Btuh
Ducts 3561 Btuh Ducts 4598 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21100 Btuh Use manufacturer's data
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 20893 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2360 Btuh
Ducts 606 Btuh
Central vent (0 cfm) 0 Btuh
Heating Coolingg (none)
Area(ft2 1820 1820 Equipment latent load 2966 Btuh
Volume(ft3) 16012 16012
Air changes/hour 0.26 0.14 Equipment total load 23859 Btuh
Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NBO30 Cond CH14NBO30
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh
Temperature rise 27 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual airflow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=32 OF
Backup:
Input=7 kW, Output=22477 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
t - - wrigfrtsoft' 2018-Nov-06 15:33:26
�— Right-Suite®Universal 2017 17.0.21 RSU25554 14CCN ...ightsoft Files\Express horn Page 1
'FORMbR405-2017
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative(Performance)Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(one page)and an input summary checklist that can
be used for field verification (usually four pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
❑ Mandatory Requirements(five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
1 1/6/201 8 3:32:37 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
PASCO COUNTY
BUILDING CONSTRUCTION SERVICES
PASC a 8731 Citizens Drive Date:4/4/2019
COUNTY FLORIDA Suite 230
OHN SP.AQ3.RIBRAN7.PIACES• New Port Richey, FL 34654
727-847-8126
** NOT A PERMIT **
Receipt#: 1836495
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1434877 $51.13 $51.13 1836495 3/5/19
Waste Single Family
TOTALS: $51.13 $51.13
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1836495 Check 886832 SLEBLANC BCCCP06W 03/05/2019 $51.13
Total Payments: $51.13
Pa or Address Phone
DR Horton,Inc. 1341 Horton Circle
Arlington TX 76011
Comments:
City of Zephyrhills Solid Waste
Address:6878 Wagon Trail Street
Parcel:05 26 210100 01100 0140
Whi a you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card or a-check fees,NOT shown above,Is
collected by First Billing payment services.
i
i
f
I
i
MyReports/reports//PASCOPROD/PASCO/ReceiptAA_V7.rpt 4/4/2019 Page 1 of 1
i