HomeMy WebLinkAbout19-21028 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21 FIRE ALARM SYSTEM PERMIT t PERMIT'INFORMATION _ LOCATION INFORMATION ''E Permit Number: 21028 Address: 6215 ABBOTT STATION UNIT 102 Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVER OAKS VILLAGE Est. Value: Parcel Number: 03-26-21-0200-00000-OOCO Improv. Cost: 1,600.00 OWNER INFORMATION Date Issued: 4/18/2019 Name: ASHINGTON MANAGEMENT LLC Total Fees: 150.00 Address: PO BOX 48155 Amount Paid: 150.00 TAMPA FL 33646-0144 Date Paid: 4/18/2019 Phone: Work Desc: ADD 6 FIRE ALARM DEVICES TO EXISTING SYSTEM CONTRACTORS APPLICATION FEES " SPECIALTY ELECTRONIC SYSTEMS. IN FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 Inspection Inspectiong Required FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME ENT " rw- 15-0—NtIYACtOR SIGNATURE PERMIT OFFIC PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 ,813-780-0b20 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received 37 Phone Contact for Permit��®T Owner's Name li"Z&10-01 44- 4- / ck Ct,-e Owner's Phone Number Owner's Address /4- 4 7- %�oN >Lo Le Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address (�.Z� �"/jrrl / F N �c.y /J�2r:� Je�� Lot# Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL Fumigation Tent 0 Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL t FyJ emi Wn-9 Sprinkler ❑ ❑ ❑ ❑ Recreational Bum Fire Alarm ❑ ❑ ❑ ❑ Sparklers n g'cr�' Hood Cleaning ❑ ❑ ❑ Sprinkler System Installations �(�� Al Hood Suppression ❑ ❑ ❑ Standpipes(Sprinkler Sys) 1 Fire Alarm Installation Torch Roofing/Tar Kettle Fire Pumps a Waste Tire Storage ANNUAL U' a Flammable Application-ANNUAL f 6,ob Uv Valuation of Project Fuel Tanks Other: Contractor Company $' edi"# Signature )2Registered Y/N Fee Current I YIN Address 7 c/ 2 64 r ei' FL License# ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered I Y/N Fee Current Y/N Address F License# Directions: - Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and-'installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in'good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally known to me or has/have produced Who is/are personally known to me or hasthave produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped' Name of Notary typed,printed or stamped F ,<< y �Cl) • O� U w pU ULL. C [4 c-1 �� 5TA-4'64 Jar"Jt Cat ► S ��oa . lf�AAYA,t it Data Sheet 2106 T" AsB_�u � tt Engineered Systems - - Discove PhotoelectricP Detector �. • DISC-P - - r 0_eserip-tion The AsBuilt intelligent analog addressable photoelectric detector(DISC-P) operates seamlessly with the AsBuilt IP Fire SeriesTm network fire control. The DISC-P communicates to and is managed and controlled by the IPF SeriesTm analog loop module(ALM). The Disc-P is physically distinguished from the Discovery ionization IF.eatures detector(DISC-])by the clear colored dual LED's.The LED's light steady when in an alarm condition and flash briefly when polled by the ALM.The Improved detection capabilities with dual LED's provide for 360 degree visibility. smoldering,smoky fires • Discovery detectors distribute O eration intelligence across the installed system The DISC-P constantly monitors its sensing chamber and its internal e Patented infrared smoke sensing electronics utilizing a patented smoke chamber and infrared smoke design sensing design. . Sleek,non-fading white polycarboriate An infrared light emitting diode with its collimator is arranged at an obtuse enclosureZero insertion force base angle to the photo-diode.The photo-diode has an integral daylight blocking filter.The IR LED emits a burst of collimated light every second. i 5 user selectable modes In clear air the photo-diode receives no light directly from the IR LED 0 Powerful transient rejection algorithms because of the angular arrangement and the chamber baffles.When 0 Conventional device mode smoke enters the chamber it scatters light from the emitter IR LED onto . Patented XPertprogramming card the photo-diode in an amount-related to the smoke characteristics and eliminates addressing errors during density.The photo-diode signal is processed to provide an analog value for transmission when the detector is interrogated by the ALM. system installation and maintenance • Alarm flag sends signal to system Upon crossing the alarm threshold the detector will make the even when device is not being determination that an alarm condition exists and send a signal to the ALM interrogated that interrupts the normal polling process to signal the alarm condition. 9 Wide variety of addressable The ALM puts the changed state on the IP network and all outputs input/output devices associated with the specific detector are activated. 0 Relay and synchronized temporal sounderbases The DISC-P manages its own automatic drift compensation thereby 0 Green/RoHS Compliant accelerating overall system performance by offloading the management of the device compensation values from the ALM to the DISC-P. Compensation is made to adjust the detector for the infiltration and Listings accumulation of dirt and dust over time.By compensating the detector alarm thresholds the sensing window is adjusted to remain at original UL File: S5022 factory specifications. CSFM:7272-1394:118 MEA:294-95-E-4 Like all Discovery devices,the DISC-P has five pre-programmed user settings that may be accessed and changed from the IPF Series network control.Further,the pre-programmed settings are utilized in establishing the automatic sensitivity values in place with the IPF Day/Night sensitivity programming. Product Data Sheet Number Rev/Revision Date = = = IPF.SeriesTm Detectors DISC-P 2106 1.4/10/1/2009 P.FIRESERIES', ©Copyright 2008 AsBullt Engineered Systems,Inc. Engineer.Specification The contractor shall furnish and install,where indicated on the plans,intelligent photoelectric smoke detectors with one of the.several addressable mounting base options available.The detector base will contain the patented XPERT programming card which will permit the free interchange of sensor heads without requiring_additional programming of the detector head or attached.base.The intelligent detector shall be self compensating,self reporting and contain dual integral LED's which will flash intermittently when polled and shall latch when the unit goes into Alarm.The detector head shall have 5 programmable settings that can be accessed automatically or by manual setting from the fire control which will allow the detector sensitivity settings of the individual detector to be modified as required.The combination of the detector head and twist lock mounting base shall be UL listed and UL listed as compatible with the AsBuilt IP Fire Series network fire controls.The detector base shall be installed without regard to wire polarity.The photoelectric detector shall be the AsBuilt model DISC-P. Technical Data Five Pre-Programmed User Sensitivity Settings Operating Voltage: 17-28VDC . Model 11%/ft.Obscuration 5 Seconds to Alarm Standby Current:400uA avg./650uA peak Alarm'LED Current:3.4mA Remote Alarm Output:5mA max Mode 2 1:7%/ft.Obscuration 30 Seconds to Alarm Temperature range:32°F to 140°F(0°C-60-C) Relative Humidity(non-condensing):0%-95% . Mode 3 . 2.3%/ft. Obscuration 5 Seconds to Alarm Clean-air Analog Value:23+4/-0 Alarm Level Analog Value:55 Mode 4 2.3%/ft.Obscuration 30 Seconds to Alarm Wire Supply:Two-wire supply, polarity insensitive • Recommended Spacing: Meets the 30%(9.1 m)spacing guidelines in NFPA 72 Mode 5 2.9%/ft.Obscuration 5 Seconds to Alarm Chapter 2, however,this spacing is based on ideal conditions and should be used as a layout guide only. Ordering Information Part Number Data Sheet Description DISC-P 2106 Intelligent Analog Addressable Photo Detector(model 58000-650) DXP-6 2310 6"Low Profile Base w/Expert Card(model 45681-250) DXP-4 2310 4"Low Profile Base w/Expert Card(model 45681-210) DXP-RLY 2310 6"Low Profile 4-wire Relay Base(model MB-RLYT-AA) DXP-SND/T 2310 6"Low Profile 4-wire Sounder Base(model MB-SDRT-AA) - DXP65 2310 Sync Module for Temporal Sounder.Bases(model MB-SDRT-SM/G/R) DXI 2300 Line Isolator(55000-750) DXP-LIB 2300 Isolating Base for DXI only(45681-211) DXP-IB 2300 Line•Isolating Base for Use with XP/DISC Detectors(45681-321) DXP-XPC Additional XPERT programming card DXP-XPC#A Order"A"for Addresses 1-42,."B"for 43-84, "C''for 85-126,#for Loop# DXP-126 126 Pre-Programmed XPERT cards DXP-REM Remote LED(24V) Related Data Sheets Discovery Detectors: DISC-I,2107;DISC-T,2108;DISC-M,2109 XP Detectors:XP-P,2101;XP-I,2102;XP-T,2103;XP-M,2104 Addressable Devices: DXP-PIM/MPIM, DXP-PID/MPID, 2810; DXP-IOM,2812; DXP-SDR,.2814, DXP- 2PID, 2816; DXP-OCR;2818 Addressable Base Options:All Bases,2310 Product Name Data Sheet Number Rev/Revision Date = _ = I PF SeriesTM' Detectors DISC-P 2106 -1.4/10/1/2009 IP F4 E SEMEs-. As Built Engineered Systems,Inc. Phone: (508)788-8333 ■1451 Concord Street Fax: (508)788-8334ta'� ITAsBuilt` Framingham, MA 01701-7782 Contact:info _asbuiltes.com USA Visit: www.asbuiltes.com Engineered Systems ©Copyright 2008 AsBuilt Engineered Systems,Inc. Data Sheet 5000 ASBuLlt" Engineered Systems IP Fire Series TM FIRE FIRE FIRE FIR Addressable and Gonven#ional Pull P�sH , PULL PULL. �#a#ions f dAsBuilt D.escri pa n The AB-42SK Series are single contact, key-reset, manual pull stations designed to meet the requirements for many Features applications. They are constructed from a rugged, but lightweight, die-cast metal alloy for increased performance and • Single or Dual Action longevity. This series of stations is available in single action • Addressable or (PULL lever)or dual action(PUSH bar and PULL lever)models. Conventional The stations are provided with one normally open contact • Screw Terminal nnections connected to a terminal strip that can accommodate wiring from • Connections and AC Voltage Contact #22 to#12 AWG. Contacts are gold plated to minimize risk of corrosion. All models have been tested by UL and found in Ratings compliance with the pull force requirements of the Americans • Gold Plated Alarm Contacts with Disabilities Act(ADA). The AB-42SK Series stations are • Surface or Weatherproof key resettable. Back-box • Deeper Back-boxes O eration available The stations are operated by pulling the handle marked"PULL" • Optional Station Colors, on the front of the unit as far down as it will go. At that point, Labels & Contacts the handle will lock in place and is easily visible from up to 50 • Green/RoHS Compliant feet. The activation handle is reset by opening the station with the key, placing the"PULL" handle to its normal upright position (resetting the toggle switch when applicable)and relocking the station. On the dual action, the"PUSH"or optional "EMERGENCY"bar moves inward allowing the"PULL"handle to be operated by a single hand. Mounting Configurations Semi-Flush--All models mount on a standard single-gang back- ,AO i r box. C Q P us Surface Mount Interior--Use pat number SGB-32S or the deeper LISTED APPRQU@ metal back-box(SGB-32SD). MEA Surface Mount Exterior--Use part number SGB-32C(SG-WP)or NYC Approved the deeper die-cast,weatherproof back-box(SGB-32CD) Product Data Sheet Number Rev/Revision Date = - IPF Series Tm Pull Stations 5000 1.0/7/1/2009 IP FIRE SERIES- 0 Copyright 2008 AsBuilt Engineered Systems,Inc. Engineer-Specification The contractor shall.furnish.and install,where indicated on the plans,individually identifiable manual pull stations connected to the Fire Alarm control.The pull stations shall be monitored for device identification,alarm reporting and. trouble supervision.The pull station shall be capable of reporting to the fire alarm control and storing in.the history log activation,trouble and reset information.The single-action and double action stations shall consist of a die-cast metal alloy housing fitted with a pull out lever which,when operated, locks in position after activating an alarm initiating contact.The double-action station shall also contain an additional lever which requires depression in order to reach the pull out lever. Pull station shall utilize gold plated contacts to minimize the risk of corrosion. Pull Stations shall be key-resettable and shall be compliant with the Americans with Disabilities Act(ADA).The addressable interface device must be UL listed and UL listed as compatible with the AsBuilt IP Fire SeriesTm network 'fire controls.The manual stations shall be As Built Engineered Systems part numbers AB-42SK2(single action),and AB-42SK1 (double action). Technical Data Listings: UL, ULc, FM,CSFM, MEA Temperature: -400 to 1500F,90%relative humidity @ 1000F Switch Rating: SG-32-Micro switch 1 Amp @ 30 VDC, 1Amp-@ 125 VAC SG-42-.Toggle switch 2 Amps @ 125 VDC,2 Amps @ 240 VAC Weight: _ 1.2lbs Dimensions: 4 3/4"h x 3 1/4"w x 1.1"d Surface-Mount Backbox Dimensions: 4 3/4"h x 3 1/4"w x 2 1/4"d(outside);2 1/8"d(inside)cast and sheet metal Deep Surface-Mount Backbox Dimensions: 4 3/4"h x 31/4"w x 2 3/4"d Ordering.I nformation Part Number Data Sheet Description A1342SK2 5000 Single Action Pull Station, Key Reset, Red AB-42SK1 5000 Double Action Pull Station, Key-Reset, Red AB-42SK2-NY 5000 Single Action Pull Station, Key.Reset, Red—New York City AB-42SK1-NY 5000 Double Action Pull Station, Key.Reset, Red- New York City Related Modules SGB-32S Interior, red,surface mount,sheet metal backbox with 3/4"knockouts SGB-32SD Deep-Interior,red,surface mount,sheet metal backbox with 3/.4"knockouts SG-WP Weatherproof, red,surface mount,die-cast metal backbox with one tapped hole for 3/4" NPT fitting(same as SGB-32C) SGB-32CD Deep Weatherproof, red,surface mount, die-cast metal backbox with one tapped hole for 3/4"NPT fitting SG-GR01 12 pack of scored,plastic(acrylic)break-rods for spares or replacement Related.Data Sheets Discovery Detectors: DISC-P,2106;DISC-I,2107;DISC-T,2108;DISC-M,2109 XP Detectors:XP-P,2101;XP-I,2102;XP-T,21.03;XP-M,2104 Addressable Base Options:All Bases,2310 Addressable Devices: DXP-PIM/MPIM, DXP-PID/MPID,2810;DXP-IOM,2812; DXP-SDR,2814,DXP-2PID,2816; DXP-OCR,2818 Product.Name. Data Sheet Number Rev/Revision.Date IPF.SeriesTm Pull Stations 5000 1.0/7/1/2009 iP FIRE sewEs7 As Built Engineered Systems,Inc. Phone: (508)788-8333 �. - T.� 1451 Concord Street Fax: (508)788-8334 � ' I Framingham, MA 01701-7782 Contact:info(cDasbuiltes.com USA Visit: www.asbuiltes:com Engineered Systems ©Copyright 2008 AsBuilt Engineered Systems,Inc. SYSTEM - SENSOR® F F 1 Strobes, and Horn Strobes for � � . System Sensor L-Series audible visible notification / g� products are rich with features guaranteed to cut �t .��rE'"� F installation times and maximize profits with lower current draw and modern aesthetics. • Updated Modern Aesthetics The System Sensor L-Series offers the most versatile and • Small profile devices for Horns and Horn Strobes easy-to-use line of horns,strobes,and horn strobes in the industry with lower current draws and modern aesthetics.With white and red • Plug-in design with minimal intrusion into the back box plastic housings,standard and compact devices,and plain,FIRE, • Tamper-resistant construction and FUEGO-printed devices,System Sensor L-Series can • Automatic selection of 12-or 24-volt operation at 15 and 30 meet virtually any application requirement. candela The L-Series line of wall-mount horns,strobes,and horn strobes • Field-selectable candela settings on wall units: include a variety of features that increase their application versatility 15,30,75,95, 110, 135,and 185 while simplifying installation.All devices feature plug-in designs • Horn rated at 88+dBA at 16 volts with minimal intrusion into the back box,making installations fast • Rotary switch for horn tone and two volume selections and foolproof while virtually eliminating costly and time-consuming ground faults. • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before To further simplify installation and protect devices from construction device installation damage,the L-Series utilizes a universal mounting plate for all • Electrically Compatible with legacy SpectrAlert and SpectAlert models with an onboard shorting spring,so installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range • Listed for wall mounting only of application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING ��� APPROVED S5512 FM approved except 7125-16530504 S4011 for ALERT models 7135-1&r,30503 3057383.3057072 L.Series Specifications Architect/Engineer Specifications General L-Series standard horns,strobes,and horn strobes shall mount to a standard 2 x 4 x 1 7/e-inch back box,4 x 4 x 1'/.—inch back box,4=inch octagon back box,or double-gang back box.L-Series compact products shall mount to a single-gang 2 x 4 x 17/e-inch back box.A universal mounting,plate shall be used for mounting ceiling and wall products for all standard models and a,separate universal mounting plate shall be used for mounting wall compact models.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also, L-Series products,when used with the SyncsCircuit-Module accessory,shall be powered from a non-coded•notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notificatioh appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L=Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered•power supply. Strobes and horn strobes shall have field-selectable candela settings including 16,30,75,95;110,135,and 185: Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary.-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model. listed to UL 1971 and UL 464 and shall.be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash,tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe . models shall operate on a coded or non-coded power supply. Synchroniiation Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize SpeotrAlert strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair.of wires.The module shall mount to a 41 V16 x.411/16 x 21/8-inch.back box,The module shall also control two-Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded powersupply. Standard Operating Temperature 32'F to 120°F(0'C to 49°C) Humidify Range: 10 to 931/6 non-condensing Strobe Flash Rate 1 flash per second NominA.Voltage Regulated.12 DC or regulated 24 DC/FWR'•? Operating Voltage Range 6 to 17.5.V(12 V nominal)or 1'6 to 33 V(24.V nominal) 'Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal) . 'Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7"W x 1.91"D.(143 mm L x 119 mm W k 49 mm D) Compact Wall-Mount Dimensions(including lens) 5.26"L x 3.46' W x 1:91"D(133 mm L x 88.mm W x 49 mm D) 'Horn Dimensions 5.6-L x 4.7"W z.1.25`D(143 trim L x.119 mm.W x,32 mm D) Compact Horn Dimensions. .5.25"'L x 3.45"W x 1.25".D(133mm L x 88mm W x 32mm D):- - 1.Full Wave Rectified(FWR)voltage is a non-regulated;time-varying power source that is.used on some power supply and panel outputs. 2:Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. co m V m w A w Q— 'M '_ :P? co 'W ;co 'Z �Z --I '1 W W co Co. Z. Z ]I'D' do CL er. " z z m m o. o z z . m m m' °'v (D o 03 3 w "w ° °" 3" 3 w c—I 3'. 3 a s c > > 3 3 a az. z � �. . . MI ° � m m o' o' � ° ff gyp. o. _. a > > 3 '3 c fD 3 3 w".w .w m .F 3 3 w w w. w � 7 o T m T. T T :T '=i =1.a a. N o' o. r 2 'r. 2 o o r 2 r ? rr " 2 a 2 S 2 2 m m o o a o:cfl ° ° (n. °' (o N N' N 'N N 3 �' w w_, p1' w" w �. w w ° g m w 1 tv)7 o n Z z m m a a m 3 r = r. _ Ul Ul o ° a 3 3 Q. W CD a m m" o o. CO) W. 5 3 3 g 1p O O .V m Co V -� m' m -� (D (D (D (D (D (D' '(D co D m w. .7 V O. m W CO W u+ Q) C.) (D "� W CO .o w .m as z z z z z CO •v .1: 01 W U1• v CD :ul 0. Q < N O O O10 O cc o< - O• m pO W' W W D O` W O O O W O O Ul O Ul Ul U7 m 'Ui U1 O' .. 7 rt N. 1 Ul A Ut V a m N A m m m .A .m O. co m V m V m V m V".m G ,< �. N N m W la p A Ul V A °m W 0) Ul A n 0 W. CT v rt (D fn rr. p _ -+ V U1 m* A' Ul' Ul' V A Ul i Ul' V A M "Cn m A Ul N N (D Ul Co -+ .W 'A A, cn _ _ ) CO (D p� m "O7. Oo, pppp (D, m, m m V Ul Ul V Ul Ul m o .N N pppp mO (D O W (D N m A• O W CD• O o< O. 'W Ul O V U7 W W (� V cD cD cn m � 10 co W co m co m m m m m N s .� N -1 (O V W m V V. CO m V CO (D O W W :N m A .O. W CD V A m V m Ut V 0N O m' W" s ,A' m A 40 n CL G: Go (� W W"W 'w z z "-1 1 .N m m• � a � � � � = = 3' 3 c 2 a 2 2 2 2 i � -0 o. CL _ _ _ N N N N N m":co "m W do (o W u , W N N "C) �Z Z --I � �.'30' w N' 0�1 '(D O. m 'm V O Ul Do' .G W Ul' N (D co' co' i G O. 0 7 3 3 N W. (D d (CD O O, _ 3, 3 0 0 — co: w w WNW W• NNN• WWN W W W N W W Ul W A. W m (�,1 A. cn - - 'A A N 'A Ul J, 'W cn CO. V W O CD" CD W N O. 4 CL ? ? r = r ? r ? r ? c=r s =r c=r J J " (D N• V W CO V CO m V 0 m m N 'Ul a) ' m m'. W � --� V V(71 N m O' Am 'N' V N Cf ,P• N 4A 1i 'A Q.' N CO CO. N (D (D (D W co (D WW A v N 00 N DOD Ln O O 1 'T. m N 0) CL AA Q. � .A .N W N A N V N r, ..a. W V" (D W A m W A W '0) A OD G N y (Jl N (D N W �Ul to .o .n: Ul Ul Ul Ul Ul .1 �U7ll m U1 Ul. N. A A A A. A A A . L-Series.Dimensions 1.91 3.46 3.46 1.25 1.25 0 0 0000 0 o o°o oyh° p°°°pop°0po oloofoo e 00000000000 ....... °0°0°0000000 5.27 5:27 0 o0 o0 00000• o°o°o°o°o°o° o°o°o°�° 5o���a�o ��o�0ror o o Compact Strobe/Horn Strobe Compact Horn 00 1.91 1.25 1:25 5.67 .67 �4444�� Strobe/Horn Strobe Horn 6Series Ordering Information Model Description Model Description Wall Horn Strobes Homs P2FiL 2-Wire,Horn Strobe;Red HRL Horn;Red' P2WL. 2-Wire,Horn Strobe,-White' HWL- - Horn,.White : P2GRL 2-Wire,Compact Horn Strobe,Red HGRL Compact Horn,Red - P2GWL 2-Wire,Compact:Horn Strobe,White HGWL. Compact Horn;.White - P2RL-P 2-Wire,Horn Strobe,Red,Plain. Accessories P2WL-P 2-Wire,Horn Strobe;White,Plain TR-2 Universal Wall Trim Ring Red P2RL=SP 2-Wire;Horn Strobe,.Red,FUEGO TR-2W. Universal Wall Trim Ring White P2WL-SP. 2-Wire,Horn Strobe,White,FUEGO SBBRL Wall Surface Mount Back Box,Red Wall.Strobes SBBWL Wall Surface Mount.Back Box,White SRL : Strobe,Red SBBGRL Compact Wall Surface:Mount Back Box,Red SWL Strobe,White, SBBGWL Compact Wall Sur%66 Mount Back Box,White. SGRL Compact Strobe,Red SGWL' : Compact Strobe,_White SRL-P Strobe,Red,Plain SWL-P Strobe,White,Plain SRL-SP. Strobe,Red,FUEGO SWL-CLR-ALERT Strobe,White;ALERT . Notes: All-P models have a plain housing(no"FIRE"marking on cover) All-8P models have"FUEGO"marking on cover All-ALERT models have"ALERT"marking on cover �'� STEw/l change 3825 Ohio Avenue•St.Charles,IL 601.74 mzot7 system,sensor. •r` ��I� Phone:800-SENSOR2•Fax:630-377-6495 Product specifications subject to wi)hout notice.visit systemsensoccom SENSOe for current product information,including the latest Oersion of this data sheet. R www:systemsensor.com AVDS86503.03/17 A City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: S et? ( Date Received: Site: � 2 1-5- Permit Type: 4// Approved w/no comments: ' Approved w/the below comments: Cl Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Gene Brown—Fire Safety Officer IYate Contractor and/or Homeowner (Required when comments are present)