Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-20514
CITY OF ZEPHYRHILLS > 5335-8TH STREET (813)780-0020 20514 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:20514 Issued: 11/28/2018 Address: 2971 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER Amount Paid: 17,790.47 Date Paid: 11/28/2018 Parcel Number: 25-26-21-0100-00000-0560 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2, 276 SQ FT APPLICATION FEES . BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 3,j q-�9 Ole, Inspections Required FO TER 2ND ROUGH PLUMB misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CON RAC S SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-2971 Moulden Hollow Drive 2,276 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,790.47 o I rL Muff. I City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Lq ab Date Received: / Allwne, Site: 17f N �N[�� Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ i I This comment sheet shall be kept with the permit and/or pl V NOV 2 7 2018 ]Jim- K-alr,p6er—Plans Examiner Date ontractor and/or Homeowner (Required when comments are present) 7 ' Ilffilifllii11111IIllliIillllflllllllllllllllllllillllllllls -- 2018198382 ---------- Rcpt*:,2008645 Rec: 10.00 DS: 0.00 IT: 0.00 11/27/2018 K. S. , Dpty Clerk PAULA S.O'NEIL,Ph.1).PASCO CLERK & COMPTROLLER 11/27/2018 10:43ayn I of I OR SK 9822 PIS 2368 Permit No. Parcel ID No 26-26-21-0100-00000-0560 NOTICE OF COMMENCEMENT state of Florida County of— Pasco THE UNDERSIGNED hereby gives notice that improvement V411 be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following Information Is provided In this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PI3 76 PG 77 LOT 66 Street Address: 2971 Moulden Hollow Drive Zephryhills FL 33541 2. General Description of Improvement Single Family Residence Pool Screen Enclosure I Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL�33607 Address city State Interest In Property: Name of Fee Simple Titleholder: N/A (if other than owner) Address city State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL,,33607 Address city State Contractor's Telephone No.: 813.574.5700 5. Surety: — NIA Name Address city State Amount of Bond: Telephone No.: 6. Lender: N/A Name Address city state Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes. LLC Name 4600 W Cypress'St. Ste 200 Tampa FL, 33607 Address city State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration.date of Notice of Commencement Is one year from the date of recording unless a different date Is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY, A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING'WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS SiJ11-ature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 18 day of October ,by Steve Robert Smith as Vice President (type of attorney In fact)for Lennar Homes, LLC (name of!a�rty,,On ��s4t�rumTent was executed),* Personally Known N OR Produced Identification n Notary Signature Type of Identification Produced Name(pr4niN Z-H§—sa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated In it are true to the best of my knowledge and belief. C4 ELISSAX HOUERAN Signature of Natural Person Signing Above C1111111111810n Al FF 985631 Explres June 8;�020 wpdatatbcsibcs formi im Al T STATE OF FLORIDA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE ANC CORRECT COPY OF THE DOCUMENT �'»r rr•u>y o ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HAND AND OFF AL SEAL THIS '7 A DAY OF 2() too PAULA S. O'NEIL', L R &COMPTROLLER `n�� BY DEPUTY CLERK I PASCO COUNTY, FLORIDA Permit No. 2-6 51 Date Permitted -Z - Builder Name/Owner Name ►" LL C Control County Parcel No. 25--Zlo- 2l- 0t0--()U)aO- US(90Div: p�!-fi[�d U��e.r, Address/Location ZCI 7 1 /vw,d&C'n P'-6 C�&4D Classification/Type of Use �e- 7r Z7 TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2 z Z Exempt ❑ Yes ❑ No How Determined Impact Fee Amount $ ��('3 6b Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7j C(.q. 2-t (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ _7 69� S Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By "`� 32� Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY I Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permif owner on notice of this assessment and the conditions of payment for same. i DATE RECEIVED BY RECEIPT NO. DATE BY i I PASCO COUNTY PADEVELOPMENT SERVICES il. _L A.SG- Y 8731 Citizens Drive Date:2/12/2019 COUNTY FLORID New Port Richey, FL 34654 ?rrrl.'irn i:.VrUrcLvrlh.nirr.• 727-847-2411 NOT EST Receipt M 1830225 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential.Solid 24503100-329010 1:00 1427591 $60.30 $60.30 1830225 2/12119 Waste Single Family TOTALS: $60.30 $60.30 Receipt# Paid By Check# CC Auth# Cashier ID. Workstation Receipt Date Amt Paid 1830225 Check 1155447 BCCCP59W 02/12/2019 $60.30 Total Payments: $60.30 Pavor Address Phone Lennar Homes, LLC Comments: 2971 Moulden Hollow DR 41/5 --- - While you will be paying your bill with Pasco County Development Services,the full amount of the credit card ore-check fees,NOT shown above,Is collected by -- - - - - First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6.rpt 2/12/2019 Page 1 of 1 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received OC 2 Phone Contact for Pe 813 363 _ 2891 1 1 1 1 1 1 1 1 �18 1 1 1 1 1 Owner's Name Lennar Homes,LLC Owner Phone Number T813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number I Fee Simple Titleholder Name N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 2971 Moulden Hollow Drive LOT# 0560 SUBDIVISION Hidden River Phase One B PARCEL ID#1 25-26-21-0100-00000-0560 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT 0 SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 2276 SQ FOOTAGE 1817 HEIGHT 1 Story OBUIL ING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE ® PROGRESSENERGY Q W.R.E.C. PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS 171 ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Flo BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.C ess St.Ste. ,Tampa,FL 33607 License# I CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N i Address 1034 Skip Road,Pwlipa, FL 33613 License# I EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 8, Bayon t, 34674-5308 License#' I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE F REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 53 Bayone 34674-5308 License# I CAC058062 OTHER COMPANY KSterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N J FEE CURREN I Y/N Address 4211 Shoal Li a Ivd, Spring Hill, FL 34607 License# CCC057991 111111111111 .1111 111111111111111111111 .11111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. 1 : 1 1 1 1 : : 1 1 : 1 1 1 . 1 1 1 1 1 1 1 :—:..:--. ..--:•-:.-. . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) `* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW I NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and.land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida 'Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN A-Tr6RNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR .Subscribed and sworn to(or affi d)before me this Subscribed and sworn to(or affirmed)before me this 1 o-yc[-1 o by Ashlee C n by Ashlee Callahan Who is/are personall knownddme or Who is/are personaliv kno 0 as entification. identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,orinttiedyvor stamr)ee??dyy Name of Notary typed,printed or stamped p p J r q 3qp 13618+F19NeI1VNMNId}� Ell — �1� . i Lennar Homes-2971 Mollden Hollow Dr:2,276 sq ft Column SO. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 i OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 Public Fee 1% TOTAL $ 2,067.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,194.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,795.47 i i i Single Family Dwelling Plan Review Comments 1: F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt.is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage.unless protected by approved barriers. M303.4,of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke�detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C.- 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker: 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage: They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23..Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25: Blower door test and blown in insulation card shall be provided before C.O. 26. A cony-of the energy cacls shall be with permit at all times. 27. Copy of final insulation report shall be pr'oiided with perinit before:fnaL 28: No fence,.pool or screen-enclosure is,ksued with this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) 25-26-21-0100-00000-0560 Pasco County Property Appraiser Page 1 of 1 i Data Current as Of: Weekly Archive - Saturday, November 24, 2018 Parcel ID 25-26-21-0100-00000-0560 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 2971 MOULDEN HOLLOW DRIVE ZEPHYRHILLS, FL 33540 ,lust Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 See Plat for this Subdivision Taxable Value $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 56 OR 9814 PG 778 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) _ Line Use Description!ZoningTnits____IType _ Price - Condition Value 4- -- 1 0100 SFR MPUD 1 6,00_0.00_ i _ SF _ _ $4.50 _1.00_ i $27,000 - - 600.00 SF 1.00 $5402 0100 MPUD _ Additional Land Information Acres 0.15 Tax Area FEMA Residential Code HDRVLPI �- --- I 30ZHI Code 1 Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line D—__ _ escription iYear _ _ ,Units ___ ____VValue No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC M onth/Year -jBook/Page Type _ IDOR Code Condition ;Amount 11/2018 9814 / 0778 Warrant Deed 05 Vacant Multi-Parcel Sale -Co --Amount -------- -- ---- - I -- --� ----- Y ------ ----------------- ------- _ 09/2011 1 8606 / 33_76__ _ _Warranty Deed -05 _ _Vacant Multi-Parcel_Sale_ 06/2010 l 8360 / 1872 Certificate of Title j 12 I Vacant j�— $0 http://search.pascopa.com/parcel.aspx?parcel=2126250100000000560 11/28/2018 a e � - e � d°^ 4 • co •,.• �E $ 1 � h, � { { ,,, ,,� A ' a a = * # ,��'�.'►' �� to"� � � �� '�'� '..._ � � � �w +•••-.+......wn—.-.•..a;r...:�yp.r.e�w.s E7 �.....1•...,�,,� �1 - -^'�-.•.••`•�...•••.+�-�_. r .i j .,,.:.`.;J. .. 3 a�[.��jaeJ ,�j3�i •1"`j_•' �'��FF.F R/q# � � 3�iEs+:....�. ... '• t-�'S/�' �'t r '_- -ij!"ly.:.' � ,yar- .,•p•"'"•.•�lp•' �{� '"`�.�°'+a� 'a'�tlr�j , t� � -- _ - �''+ -'^. ,+•�i.�.•`.'-`r. •. _ -':- {$$' • � :.�;,.' d�, �� �M ate. 'b' ''\'�`•S,. ¢ � �',`�`"�"".`;•-••• v-::y"":=�'.•-:__: '.i-'r :: i. 1 t r PIP r Co R 60 4 t t $ Oleve Nd- XL lie Fil 7" Buildin-and Construction Services(BCS) PASC �4 COUNTY FLORIDA-, Blower Door Test Report Form 01,Fs", Property Address: o19-71 MovVen tkito Or%-VP— ?-P-9hyrWIkI.5, F-I 3 35-L-10 5-(0 Permit M Testing Company Name: Skyetec Test Date: 3 A5-/l-I Tester Name: Jeffery Morford Tester Cert#: Contact Phone: WTLD7R 904-903-0660 Email: jmorford@skyetec.com 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). As required by the Building Official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled penetrations of the building thermal envelope. During testing:(check to verify condition met) E6xterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather-stripping or other E(Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond 2/tended infiltration Interior doors,if installed at the time of the test,shall be open V21"Er. erior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed Mea ,ting and cooling systems,if installed at the time of the test,shall be turned off U/sup-Ply and return registers,if installed at the time of the test,shall be fully open Vb Building volume(ft 3 /S. 0 Q50 Airflow at 50 Pascal(CFM) ACH50 Air changes per hour at 50 Pascal Q50 x 60—Vb== s,q ACH50(3.0 A CH minimum) Pass Fail M Outside Air mechanically introduced to space(less than 3.0 ACH) I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Signature of Test ff Date Ler S(S 6-SIB hit Strbam° Ultra Blowing Wool Insulation kNAUF4�U4��� Attic and Cavity Wall Card �-1 MD U Iclen � I I ow ib i7wfe>Lo 1AV2 Uerq/f Batts and Blankets Equipment Required (�/ When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'/4'internal corrugation,a minimum length recommendations,Knauf Insulation batts and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed provide the full R-value. rate is 15-25 lbs/minute. R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the Installed insulation should required number of bags per 1,000 square feet and exceedingthe maximum square feet of coverage per bag as recommended b the label insulation resistance not be less than: g p q p 9 y (R-Value)at: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. R 49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. R-38HD 10.25" R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum To obtain an The number of bags Coverage per Bag Weight per SF R-30HD 8.25" insulation per 1,000 square feet Contents of this The weight per square R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. R-21HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 lbs. R-19 6.25"'" R-15HD 3.50" 2°x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. R-13 3.50" 2nx 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. R-11 3.50" •R means resistance to heat Dow.The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulation be installed property. I R-8 2.50" R-18 in a 5.5'cavity.Conforms toASTM C 665 and Federal Open Attic Application Bag Net Weight-Nominal 321bs.,Minimum 31 Ibs. Specification HH-1-521F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members,the number of bags per Thickness The number of bags/ Contents of this The weight/SF Contents of this 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should Ba s/MSF Ba s/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more 9 9 resistance(R-Value)of: than: more than: be lessthan than: than: Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952 lbs. 19.750" 19.760" R-Value Dimensions Framing Framing 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs, 16.375" 16.375' R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875' 14.875" I 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 lbs. 13.000, 13.000' 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10,375' 10.375" R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" 2x8 22.4 22.7 2x4 20.4 20.6 R 22 9.8 102.2 SF 313 lbs. 7.750° 7.750" R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 lbs. 6.750" 6.750" 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 lbs. 4.750" 4.750" 2x4 17.3 17.4 R-11 4.7 1 210.8 SF .152 lbs. 4.000" 4.000" R-38 2x6 17.0 17.2 Bag Net Weight-Nominal32 lbs.,Minimum 31 lbs. 2x8 16.7 17.0 Coverage and installation data were deterr med using a Volu-Malice II blowing machine in thind gear with 13'gate opening,2.0 psi air pressure and 15D or 3'intema0y oormgated hose. This product conforms to the performance requirements of ASTM C 764,Type I,and cancelled Federal Specification HH-1-1030B,Type I,Class B.R-values are determined in accordance Wth C 687 and C 518. 2x4 13.2 13.3 "R'means resistance to heat fiaw.The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulation be installed property.If you do k yourself,get inst c- R-30 2x6 12.9 13.1 tons and follow them carefully.Instructions do not come with this package, '*Based an Third Party 2-year settling study,the predicted settlement over a 20-year period would be 1 percent or less.This amount of settling is thermally insignificant Therefore,the installed and settled 2x8 12.6 12.9 thicknesses are effectively the same. 2x4 11.3 11.4 Vol-Marcell is a registered trademark of Unisul. R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 2x6 9.1 9.3 Attic Area R- at Inches 2x8 8.8 9.1 Sloped Ceilings R- at Inches j 2x4 7.9 8.1 Walls R- at Inches R-19 2x6 7.7 7• 2x8 7.4 7.7 Floors(over an unheated crawl space) R- at Inches 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches R-13 2x6 5.0 5.2 Date Installed 2x8 4.8 5.0 Blown' lation has been i tat ci in conformance with the above recq nend do o provide an R-value of 2x4 4.3 4.4 R- � using bags of this insulation to covert square feet of area R-11 2x6 4.1 4.3 at a minimum thickness of�_inches. 2x8 3.8 4.1 00uL E..imnmenr Insulation Contractor(signal ) GREENGUARD Gold°' UL Enw.vlanon GREEN UARD on odnd i, Company r� Date I 1� UL Environment boding UARD Gdd and is 6 UL Emiro"menr volidmed b be formaldehyde flee G. / UL Envimnmant GREENGUARD Home Builder(signature) 0 certification Pmgmmi- Pmdvm me oem6,1 w UL Ermronmem GREENGUM,D dmdrlml-demlcal Company Date mo Inaaar air d"eng prod,mage. Far mom Inrormmion,vinh ul.com/gg. The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). www.knaufinsulation.us Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-4434 ext.8300 FAX:(317)398-3675 ©2015 Knauf Insulation,Inc. t � Jacqueline Boges From: City of Zephyrhills Support <support@zephyrhillsfl.zendesk.com> Sent: Thursday, November 29, 2018 4:34 PM To.� Jacqueline Boges Subject: [Request received] 2971 Moulden Hollow Dr by#20514 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/reouests/252829 ! I ................................................................................................................................................................................................................................................................................................................................................... I 1 Jacqueline Boges - Nov 29, 2:34 PM MST new service 2971 Moulden Hollow Dr by#20514 I This email is a service from City of Zephyrhills Support . I 1