Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-20518
CITY OF ZEPHYRHILLS 'i 5335-STH STREET F (813)780-0020 20518 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - LOCATION INFORMATION Permit#:20518 Issued: 11/28/2018 Address: 39607 DAWSON CHASE DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 18,442.97 Subdivision: HIDDEN RIVER Amount Paid: 18,442.97 Date Paid: 11/28/2018 Parcel Number: 24-26-21-0100-00000-0170 . CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 WATER CONNECTION RESIDENI 1,010.00 SEWER CONNECTION RESI DEN- 2,090.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections R uired FO TER 2ND ROUGH PLUMB M13C INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Rennspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. i C RA ORS IGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER S` City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 3���7 CT �� ► ('� �. Permit Type: s Approved w/no comments:❑ Approved w/the below comments Denied w/the below comments: ❑ L� This comment sheet shall be kept with the permit and/or pl s. P/11/1 N�-" 2 7 2�D1� \ Kalvin Skvitze Plans Examiner Date Df ontractor and/or Homeowner (Required when comments are present) 2018198374 Rcpt:2008645 10-00 DS: 0.00 IT: 0.00 11/27/2018 K. S. , Dipty Clerk PAULA S.O'NEIL,Ph.D.PASCO CLERK & COMPTROLLER 11/27/2018 10:43am 1 of I OR 8K 98242 PG 23660 Permit No. Parcel ID No 24-26-21-0100-00000-0170 NOTICE OF COMMENCEMENT State of Florida County of — PaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following Information Is provided In this Notice of Commencement: I Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 17 Street Address: 39607 Dawson Chase Drive Zephryhills FL 33541 2. General Description of Improvement Single Family Residence I Pool Screen Enclosure Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St.Ste 200 Tampa FL. 33607 Address city State Interest In Property: Name of Fee Simple Titleholder: N/A (if other than owner) Address city State 4. Contractor: Lennar Homes, LLC 1Name 4600 W Cypress$t, Ste 200 Tampa FL,33607 Address city State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address city State Amount of Bond: Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone NO,: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: I Lennar Homes. LLC Name 4600 W Cypress St, Ste 200 Tampa FL,33607 Address city State Telephone Number of Designated Person: 813.574,5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement Is one year from the date of recording unless a different date Is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR.NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 9 day of October ,by Steve Robert Smith as Vice President (type of authority,%g.,officer,trustee,attorney In fact)for Lennar Homes, LLC (name W-ob o whom Instrument was executed), Personally Known Z OR Produced Idenifficatlon 0 Notary Si ignSa ISf S� � Type of Identification Produced Name( liss�.Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated In It are true to the best of my knowledge and belief. ELISSAM.HOLLERAN Signature of Natural Person Signing Above C-61111111181on I FO 111115637 EXPIres June 0,2020 wpdatalbes/bes form., i c STATE -FLOP11DA,COUNTY OF POW THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT f ~ ON FILE OR OF PUBLIC RECORD IN THIS OFFICE- WITNESS MY HAND AND OF ICIAL SEAL THIS a ,, yG: ;�•r Trcur DAY OF _z PAULP S.O'NEIL,CLE K& OMPTROL ER V�qJ BY DEPUTY CLERK fcs�r Lennar Homes-39607 Dawson Chase Dr-3,046 sq ft _ i Column SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES j PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 I SUB-TOTAL $ 6,842.13 j PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 i TOTAL: $ 18,442.97 24-26-21-0100-00000-0170 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, November 24, 2018 Parcel ID 24-26-21-0100-00000-0170 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 39607 DAWSON CHASE DRIVE ZEPHYRHILLS, FL 33540 Just Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 17 Taxable Value $27,540 OR 9814 PG 778 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use jDescriptioniZoning Units Type— Price Condition Value ----- ------- --- 1 i 0100 SFR MPUD_ 6,000.00 SF $4.50-- 1.00 _ $27,000- ------- ------------- ----- 2 I 0100 SFR MPUD 600.00 SF $0.90 j 1.00 $540 Additional Land_Information Acres 0.15 Tax Areai 30ZH i FE Code de Residential Code ( HDRVLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line _ Description-tion Year Units ;Value — ----- - -----'—j ----------- — ---- -- --- ----- —--No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type ODOR Code Condition Amount - 11/2018 j 9814 / 0778 Warranty Deed 05 ��Vacant— Multi-Parcel Sale 09/2011_ / 33 8606 76 Warranty Deed _05 _ Vacant ( _Multi-Parcel Sale 06/2010� 8360 / 1872 , Certificate of Title 1 12 — Vacant $0 I I I i http://search.pascopa.com/parcel.aspx?parcel=2126240100000000170 11/28/2018 • I PASCO COUNTY, FLORIDA Permit No, ,, Date Permitted 11 Builder Name/Owner Name e A-n -f l Mq�-� Control#' County Parcel No. 2 00 - bW-6/70 SubDiv: ` ddfa Address/Location Z 9 7 k Ct Classification/Type of Use 131 TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit* M Exempt ❑Yes [] No How Determined Impact Fee Amount $. Zone No. TAZ: i SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ _y24 (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total i Recreation Account Recreation Credit Recreatioonn Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total l I, Exempt ❑ Yes ❑ No How Determined Total Amount c RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY s � A606W lei 16A L'dr/7 PASCO COUNTY P DEVELOPMENT SERVICES 8731 Citizens Drive Date:2/11/2019 COUNTY FLORIDA'y New Port Richey,FL 34654 OPEN SPACES.I/iewv n•NACB. 727-847-2411 NOT A PERMIT Y. Receipt#: 1830072 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1427398 $60.30 $60.30 1630072 2/11/19 Waste Single Family TOTALS: $60.30 $60.30 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1630072 Check 1155434 BCCCP59W 02/11/2019 $60.30 Total Payments: $60.30 Pavor ddress Phone Lennar Homes, LLC ` (� Comments: ee)l 'll 39607 Dawson Chase DR -While you will be paying your bill with Pasco County Development Services,the full amounfof the credit card or a-check fees,NOT shown above,Is collected by__ First Billing payment services, • I L i I MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 2/11/2019 Page 1 of 9 Lennar Homes-39607 Dawson Chase Dr:3,046 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 Public Fee 1% TOTAL $ 2,720.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER IVIETER:l $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,847.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,447.97 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be.graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie iri survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be.met. 7. All property markers shall be uncovered and marked at time of-first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302,6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B:C 12. Water heaters'shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M13.08.1 14. Return-air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be 'installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308A of the F.B.C. 17. All means of egress are to be- in accordance with R311 of the F.B.C. 18. "Green gypsum board"shall not be used as a backe'r.in showers or tubs. R702.4.2-T.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil�burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2616 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 . 24. In accordance with the Land Development Code, lots shall be.sodded before final at least 10 feet around the structure. 25. Blower door test and blown in insulation card shall be provided before C.O. 26. A cony of the enemy cacls shall be with permit at all times. 27. Copy of final insulation'report shall be.provided with:permit before.rnab 28. No fence,.pool or screen-enclosure is.issued with this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6 h Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) 813780-002O City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received OCT 2 9 2PIR Phone Contact for Permlftln 813 363 2891 I 1 11 a Lermar Homes,LLC 813.574.5700 Owner's Name Owner Phone Number Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name [N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS [39607 Dawson Chase Drive LOT# 0170 SUBDIVISION Hidden River Phase One B PARCEL ID# 24-26-21-0100-00000-0170 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH Pq INSTALL8 REPAIR PROPOSED USE SFR 0 COMM 0 OTHER TYPE OF CONSTRUCTION u r o BLOCK 0 FRAME STEEL Q _J DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence I I 3046 IP C Story BUILDING SIZE � U/R S SQ FOOTAGE HEIGHT . . . . . . . . . . . . . . . . BUILDING $Atf I?, VALUATION OF TOTAL CONSTRUCTION ELECTRICAL 1$ AMP SERVICE ® PROGRESS ENERGY Q W.R.E.C. b0 PLUMBING 1$ MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY Q OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDER COMPANY I Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN 2 Ste W.C#ess St. . mpa,FL 33607 Address 4600 W p5-, f a I License# EGC1518166 ELECTRICIAN COMPANY I Edmonson Electric, Inc. SIGNATURE REGISTERED L_Y_L N J FEE CURREN LILN__j Address 1034 Skip r oad,T FL 33613 License# EC13005408 PLUMBER COMPANY [Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N J FEE CURREN L_yl N_J Address P.O. Box 53&, ayonet/FX4674-5308 License# [6FC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE F REGISTERED Y/ N FEE CURREN Address P.O. Box 5308 yonet,YL,8674-5308 �A7C058062 License# F OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N I Address 14211 Shoal Lin&d, Spring Hill, FL 34607 License# CFCCO57991 I I I I I I I I I I I I I "t/hs;,l I I I I I I I I I I I I I I I I 1 .1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RESIDENTIAL Attach(2)Plot- ;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Iwo Minimum ten(I )working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets.of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7600) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW . . ,. . NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations, The undersigned assumes responsibility for compliance with any applicable deed restrictions. ' UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by |ew, both the owner and contractor may be cited fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to vvhed licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building inspection Division—Licensing Section at 727-847- 8009. Furthanno*e, if the owner has hired a contractor or contracton*, he in advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may ba on indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION l8HPACTIUTYLYTTE0 IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply tothe construction of new buildings, change of use in existing bui|dingu, or expansion of existing bui|dingo, as opeoUUmd in Pasco County Ordinance numnberDS-O? and 90'07' as amended. The undersigned also undenatondo, that such fees, as may be due, will be identified et the time of permitting, It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power release. |f the project does not involve o certificate of occupancy or final power na|eaoe, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, aearmendmd): |f valuation of work io $2.5DO.O0or more, | certify that (, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" pnaponad by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"mmner"prior hzcommencement. CONTRACTOR`S/OVVNER'SAFPID&V[T: | certify that all the information in this application ie accurate and that all work will be done in compliance with all applicable laws regulating oonatruoUon, zoning and land development. Application is hereby made to obtain a permit to do work and installation an indicated. | codify that no work or i otaU tion has commenced prior to ionuonma of permit and that all work will be performed to meet standards of all laws nagu|mUn8 construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that I understand that the regulations nf other government agencies may apply to the intended vvork, and that it is my responsibility to identify what actions | must take tobeincompliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress8ayhoodo. Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management D|othot-WaUn, Cypress Bayheadm, Wetland Aneoo, Altering Watercourses. - Army Corps ofEngineonm-SesmveUm. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVeUe, Wastewater Treatment, Septic Tanks. ' UG Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authority-Runways. | understand that the following restrictions apply to the use offill: - Use of fill im not allowed in Flood Zone"V~unless expressly permitted. ' |f the fill material is to be used in Flood Zone "A", it is understood that n drainage | addressing a " compensating volume" will be submitted at time of permitting which ie prepared bva professional engineer licensed by the State ofFlorida. - If the fill material is to be used in Flood Zone "A" in connection with o permitted building using stem vvaU construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, '_oed�/ that use of such fill will not adversely affect adjacent properties. If use of fill is found to adveel affect acUmoont pnopedias, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for |obo |ooa than one (1) acre which are elevated by fill, an engineered drainage plan |orequired. If| am the AGENT FOR THE OWNER. | promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that oseparate permit may be required for electrical work, p|unmbing, oiQno, vwa||o, pVo|o, air oonditioning, gao, or other installations not opocUicoUy included in the application. /\ permit issued shall be construed to be o license to proceed with the work and not as authority to vio|ata, oonce|, o|ter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit in commenced within okv months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be naqueutod, in vvriUng, from the Building Official for o period not to exceed ninety (QO) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE T0RECORD A0OT|CE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTOR FORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT V CONTRACTOR Subscribed and sworn to(or affirme0before me this Subscribed and sworn to(or affirmed)before me this Who is/are personally known to 'have pFGduGe4 Who Ware personally known to me or hasihave pFedueed Notary Public Notary Public Ehssa M.Holleran ElioouM.Holleran SKETCH ONLY SEC. 24 TWP. 26 S, 'RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 17 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT 1 MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6600.00_SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA 1093 _SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY 35____SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 42_7 SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI = N,�A--SQ. FT. SHOWN. ,AAA,— = PROPOSED DRAINAGE FLOW PATIO =--1-3—SQ. FT. 10 = DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) PROPOSED-GRADE CONC. DRIVE __ 408 SQ. FT. ¢ NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & CONC PAD = 18--SQ. FT. 6 PRIVATE SIDEWALK =_ 31 SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: IMPERVIOUS = 31 % PAGE INDICATES THAT PLAT IS IN LOT GRADING TYPE = A = 20_M SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION = SOD 4565 _Sp, FT, CHANGE AND/OR REVISION. FRONT SETBACK = 20' SIDE SETBACK = 10' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON REAR SETBACK = 10' RIGHT OF WAY = 720_00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON = 144 SQ. FT.336 STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK = --SQ. FT. MEASUREMENT FROM FORM BOARDS FOUNDATION SOD =_ 336 -SQ. FT. TO PROPERTY LINE. / TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA = 7320_00 SQ. FT. DRIVEWAY = 552 SQ. FT. SIDEWALK =_ 271SQ. FT. TRACT "H" SOD = 4901—SQ. FT. LANDSCAPE &BUFER EASEMENT THE EMERALD POINTE HIDDEN RIVER PHASE ONE A RV RESORT PHASE THREE (PLAT BOOK 74, PAGES 101-121) (PLAT BOOK 38, PAGES 7-11) _ S 89'40'43" E 60.00' �,sv o�1BOUNDARY 6`• 6• :ld m: 211 O p O O O p Pln.. :10.00, L I 40'-0" LOT 18 _ U❑^ ' LOT 16 r- PROPOSED Q j- PLAN 2575 ELEV "Al b GARAGE LEFT i M O O LOT 17 " O zC (� 10:00' 10:00' t s.00' o l —_N. . — o• Q, N.N .. —N:— r�s :N N: .yl 186.15' .N 89'40'43" W 60.00' �•:.+ PLAT BOUNDARY �_PRM(P) EL , 00 N ' in in _ 00 DAWSON CHASE DRIVE HIDDEN RIVER PHASE ONE A PROPOSED: (PLAT BOOK 74, PAGES 101-121) LOWEST FLOOR ELEVATIONS: 3 (50'R/w) LIVING AREA: 77.20' DESCRIPTION: GARAGE AREA: 76.66' ~ ELEVATIONS REFERENCED TO m LOT 17, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL oAS RECORDED IN PLAT BOOK 076, PAGES 077 THROUGH 082, DATUM OF 1929. MEAN SEA; w OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. a a APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9 30 1992 Project Number. Square Feet: 6600.00 t LENNAR HOMES Z LEGEND: o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, ¢= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= p CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, 2 F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT as REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, t U P= UTILITY POLE W F= WOOD FENCE t JOHN R.BEACH&ASSOCIATES INC. SMS Drawn By: SURVEYORS AND MAPPERS hec 911 WEST ST. PETERSBURG DRIVE Checked By: y ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' n NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 8/15/18 ACS 06 /G os o THE ORIGINAL RAISED SEAL OF A FLORIDA SIGNA % ATE •5 LICENSED SURVEYOR AND MAPPER JO R. B Revisions: F RIDA REG. ND SURVEYOR No. 2984 LB 4493 JEFF M. HART i SURVEYOR & MAPPER No.7123 'Q� aor as ,..,4u MMa " _..`.. . . ..... .....-7� 74, . - - rs' :.� cif .._.. ... - �y• ..�e :-�- .. - •-... ,.�.,-,,.... .., f-'T � # �- I I ! I '. ! I I l ! ! i � I I - # # :! ! -• # �',r • ! ! I FFl, i ! I # # �- I I FF :9 # FF�� # ' ! ! w o i ( I FF fit. 9.• € i t I ! rft�a 1 .# a' € i ��rrP i ! a # E ° ! 8 'rs ! i �t :ILl i °t'� '�► r -:::l - ....... _. .. ........._.. _ . 74.70 39 92 .. 28 44 FF U. I ! I 3 A ' 9 € —————— o.�a..f - •��•.� a a eo � ❑ Pr t� io �I— �'•� �..a�o+..+.�_^.•,-.•,vnv aru raa 83 YG7alvi ,i ' -•F:,_ C� 441 6 0 O � ® � C] [9 tl L 3 ,y�� a 7 3Q = ___:—,®_ __- PASCBuilding and Construction Services(BCS) �I .� COUNTY FI.URII�A, Blower Door Test Report Form � i Property Address: Unit A: 3qCpQ7 7P /RuJScn q I �e t Permit It: 20 r Testlns Company Name: C V� C Test Date: GJ Tester Name: O / N Agbro Tester Cert n: qn C Contact Phone: 9c _ 73 a _I Email: `7 [ndt7 e .ve 402.4.1.2 Testing.Building envelope air tightness shall he demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).As required by I the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled penetrations of the building thermal envelope. j i During testing:(check to verify condition met) Id Exterior windows and doors,fireplace and stave doors shall be closed, but not sealed, beyond the intended weather-stripping or other [;Dampers Including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond �ntended infiitration I!J Interior doors,if installed at the time of the test,shall be open R(Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed eating and cooling systems,If installed at the time of the test,shall be turned off L7 Supply and return registers,if installed at the time of the test,shall be fully open Vb Building volume(W) Qso Airflow at 50 Pascal(CFM) ACHso Air changes per hour at 50 Pascal Qso x 60—Vb= ,0 ACHso (3.0 ACH minimum) Pass Fail ❑ 0 Outside Air mechanically introduced to space(less than 3.0 ACH) I hereby certify that a abo- e lope leakage performance results demonstrate compliance with o ida E re r ments in accordance with Section R402.4.1.2. Sigfurc of Tester Tate W--F I -- , #- dos I Jet Stream° Ultra Blowing Wool Insulation kNAUF4 Tw�p Attic and Cavity Wall Card 7Jo� 4 �)� C1/10 -Se, ib hme h i4ve e4er(�(/i Batts and Blankets Equipment Required ` When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum'/4'internal corrugation,a minimum length recommendations,Knauf Insulation bans and blankets will of 150'.Coils in the hose should not be less than 36'in diameter.Acceptable material feed rate is 5-35 Ibs/minute.Recommended feed provide the full R-value. rate is 15-25 Ibs/minute. R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label (R-value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. R-38HD 10.25" R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum R-30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF insulation per 1,000 square feet Contents of this The weight per square R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation R-26 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: R-22 6.50' 2"x 4" 3.50' R-15 1.8 Ibs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 Ibs. R-21 HD 5.50" 2"x 6" 5.50" R-23 1.8 Ibs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 Ibs. R-19 3.50"" 2mx 8" 7.25" R-31 1.8 Ibs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088lbs. R-15HD 3.50" R-13 3.50" 2"x 10" 9.25" R-39 11.8 Ibs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 Ibs. R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the Insulating power.To get the marked R-value,it is essential that this insulation be installed property. R-8 " 2.50 R-18ina5.5'cavity.ConformstoASTMC62.50 ederal Open Attic Application Bag Net Weight-Nominal 32 lbs.,Minimum 31 Ibs. Specification HH-1-521F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members,the number of bags per The number of bags/ Contents of this The weight/sF Thickness Contents of this 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should Ba S/MSF Ba S/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more 9 9 resistance(R-Value)of: than: more than: be lessthan than: than: Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952lbs. 19.750" 19.750" R-Value Dimensions Framing Framing 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375" 16.375" R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 lbs. 14.875" 14.875" 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 Ibs. 13.000" 13.000" 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 Ibs. 9.125" 9.125" 2x8 22.4 22.7 R-22 9.8 102.2 SF .313 Ibs. 7.750" 7.750" 2x4 20.4 20.6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 Ibs. 6.750" 6.750" 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 Ibs. 4.750" 4.750" 2x4 17.3 17.4 R-11 1 4.7 210.8 SF .152 lbs. 4.000" 4.000" R-38 2x6 17.0 17.2 Bag Net Weight-Nominal 32 cos.,Knimum 31 lbs. 2x8 16.7 17.0 Coverage and Installation data were determined using a Volu-Matic!II blowing machine in third gear w8h 13'gate opening,2.0 psi air pressure and 150'of 3'intemafiytamgamd hose. This product conforms to the performance requirements ofASTM C 764,Type I,and cancelled Federal Specification HH-1-1030B,Type I,Gass B.R-values are detemined In accordance mth C 697 and C 518. 2x4 13.2 13.3 •'R'means resistance to heat flow.The higher the R-value,the greater the insulating power.To gel the marked R-value,it is essential that this insulation be installed properly.If you do it yourself,gel insbuo- R-30 2x6 12.9 13.1 bons and fofiow them carefully,Instructions do not come with this package. ^Based on Third Party 2-year settling study,the predicted settlement over a 213•year period would be 1 percent or less.This amount of setlGng is thermally inslgnificanl Them me,the installed and settled 2x8 12.6 12.9 Ihi knesses are e8emwely the same. 2x4 11.3 11.4 Volu-Ma"I is a registered trademark of Unisul. R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 2x6 9.1 9.3 Attic Area R- at Inches 2x8 8.8 9.1 Sloped Ceilings R- at Inches 2x4 7.9 8.1 Walls R- at Inches R-19 2x6 7.7 7.9 2x8 7.4 7.7 Floors(over an unheated crawl space) R- at Inches 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches R-13 2x6 5.0 5.2 Date Installed - 2x8 4.8 5.0 BlowO' sulation has been i s Iled in conformance with the above rec m da' s p provide an R-value of: 2x4 4.3 4.4 R- �o using bags of this insulation to cover square feet of area R-11 2x6 4.1 1 4.3 at a minimum thickness of inches. 2x8 3.8 4.1 UL Emi,anm"nt Insulation Contractor(signature) a GREENGUARD Gold" N kma"f I,-.1 GREEN GREENGUARD amid-d 1d Company j�yte UL Eflln,d.s WI&9 UARD Gold and h (�- U1 Ern:,-"t validm"d b b"t«maldehyde free UL Enrir"nmenf GREENGUARD Home Builder(signature) 0 CediRr"Hon Program" Produc"are-A,d b tR Enri-M GREENGUARD"bndardr for for chemical Company Date W.indoor air d",mg produch arage For more I"IormoEon,risit ul.com/gg. The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). www.knaufinsulation.us Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825.4434 ext.8300 FAX:(317)398-3675 ©2015 Knauf Insulation,Inc. ,� 1 . Jacqueline Boges From: City of Zephyrhills Support <support@zephyrhillsfl.zendesk.com> Sent: Thursday, November 29, 2018 4:39 PM To: Jacqueline Boges Subject: [Request received] 39607 Dawson Chase dr by#20518 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zeephyrhillsfl.zendesk.com/hc/requests/252832 ....................................................................................................................................................................................... ................................................................................................................................................................. y Jacqueline Boges _ Nov 29, 2:38 PM MST new service 39607 Dawson Chase dr by#2051 8 This email is a service from City of Zephyrhills Support . 1