Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19892
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19892 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION- Permit Number: '19892 Address: 36763 EILAND BLVD Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: NEW CONST/COMM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 04-26-21-0000-00100-0060 Improv. Cost: 3,724,552.00 OWNER INFORMATION Date Issued: 6/29/2018 4kA Name: FLORIDA MEDICAL CLINIC Total Fees: 85,206.15VpP Address: 38135 MARKET SQ Amount Paid: 85,206.15 ZEPHYRHILLS FL 33542 Date Paid: 6/29/2018 Phone: 813-780-8440 Work Desc: CONSTRUCT 2 STORY BUILDING 30,350 SQ FT CONTRACTORS APPLICATION FEES WALLACE ASSOCIATES LLC BUILDING FEE 16,011.48 SUNCOAST ELECTRIC INC ELECTRICAL FEE 3,515.40 SOUTHERN EQUIPMENT CORPORATION PLUMBING FEE 2,343.60 BAYSIDE MECHANICAL INC MECHANICAL FEE 1,640.52 ALLIED ROOFING INC � SEWER CONNECTION COMMERCIAL 36,605.72 WATER CONNECTION COMMERCIAL 11,673.76 WATER METER 2 1,733.95 nn POLICE IMPACT FEE 4,947.05 1C �✓� ��, J FIRE PLAN REVIEW FEES 910.50 FIRE IMPACT FEE 5,311.25 I PUBLIC SAFETY 5% 512.92 Ins ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 36763 EILAND BLVD Owner: FLORIDA MEDICAL CLINIC ZEPHYRHILLS, FL. 38135 MARKET SQ Subdiv: CITY OF ZEPHYRHILLS ZEPHYRHILLS FL 33542 Parcel: 04-26-21-0000-00100-0060 Work Type: NEW CONST/COMM Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19892/'/f 0-//.7 it) 7a7PO4 .e707 Date: 6 06/2019 ov-61"(e. iFl� 92--X�� ISSUED BY. BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE 813-780-0020 City ofZephyrhills Permit Application Fax-813-780-0021 Building Department Date Received �.-�C Phone Contact for Permitting p Owner s Name LOR+1 DA E j GAL �.t. N 1 Owner Phone Number b - 00� y fl Owner's Address o Jq F .I If.0 Owner Phone Number Fee Simple Titleholder Name L O"'IO�AI EQIt,•A V C I-11J\C Owner Phone Number Fee Simple Titleholder Address 96135 JOBADDRESS LAdD ^n'RLAa ' %rAot4S VgL9p -ZEP ►�. L S '' LOT# SUBDIVISION IT PARCEL ID#I E)A"ZIW-7.\_000o'Op{00- 010 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR B ADD/ALT = SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE SFR �, COMM = OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK V'1 O S-r o R - llr OE S-TA N +tab— M o6 W ITN �Fv"- S, F' L1EVE o P BUILDING SIZE UJ O STo SQ FOOTAGE HEIGHT TINT ITIT!-IT 1"ITITI"ITI"ITIT BUILDING $ VALUATION OF TOTAL CONSTRUCTION 3 l00 00o ST�MAT�p� /� =ELECTRICAL $ AMP SERVICE _ PROGRESS ENERGY = W.R.E.C. =PLUMBING $ vv I� IV =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION r , r�ype =GAS = ROOFING Q SPECIALTY = OTHER ' a, FINISHED FLOOR ELEVATIONS A q •40 A p FLOOD ZONE AREA =YES NO e� C _._...T._......�.....r...r...... . . ...rT._..._....._. . ... .... . ... . . ....... ...r - - WALLAcc BUILDER C u�QL�C� /1 O ,n COMPANY SIGNATURE 'r 1 {"T F� REGISTERED Y! N FEE CURREn Y/N r Addres • tJl�• 1�• .rJb Sf T.�E E F �31 73 License# C_(0C-*-0'z_-WA ayF ��Ir (�ECECTRICIAN COMPANY i w �/'.�'r SIGNATURE (/ REGISTERED Y/ N FEE CURREt Y/N �7 L_Address] License# ' PLUMBER �' COMPANY l -SIGNATURE A REGISTERED Y/ N FEE CURREN Y/N I /, Address License# r�t A .MECHANICAL ; �`, COMPANY d ](](]( SIGNATURE �J 1�0' REGISTERED Y/ N FEE CURREt` Y/N f Il Address License# I� `OTHER COMPANY f SIGNATURE RE REGISTERED Y/ N FEE CURREA Y!N �_ —' Address License# _I I I I I III I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1t1-1_I�I r RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Fortes;R-0 W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, II/�Gt f�i Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone'V"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A' in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel,alter, or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN.ATTORNEY BEFORE RECORDING YOUR NO OF OMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGE CONTRACTOR Su scribed an swo t r affnned)before me this Subsc bed nd sworn o(or affirme )before me this - 0119 by �2 2'Zo-1 by "Apt AOA.(L.. Who is/are personally known to mg or has/have produced Who is/are personally known to me or has/have produced s identification. as identification. Notary Public Notary Public Commission No. Commission No. Mjonnm tA, LoCl(,c" THoMRS AA. Lo LvLEQ-D Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped 0,10 w Notary Public State of Florida -OY NNotary Public State of Florida ? % Thomas M LOcicerO Thomas M Locicero :< < My Commission GG 049109 r, v My Commission GG 049109 ''nor a Expires 01/13/2021 ?wog Expires01/13/2021 I=rctT�: _ Og/ 1/2�lMA_ ySA� #362 P.001 '�" �••, sl3aeo aoro City of Zephyrhills Permit App4ea6nn Fex ata,7ac dn21 stYidlnQ OipaAment Ditto ReahrrdCbtlta br Parmldl r Owasea(am: R+iGf G . owaorPh onrNumber 'L��'� Fe*6lmptt'1lth�hblderHltmt a0.tpA _�1►tA��Nl<. QrYnarPhonrNumbar fee$lpvptaMeholdvAdtiraee gtt �j i1f}:Y. K - o. l - S-M3 LOTO a 6118D1 16N �-_-w ! PARCEL It7rw ''�• 1�O Rt C?�` 1 C?t� po 4aU IveT,bAeo raax raarrerlr TA Honcq WOlsitPROFOSBO �+cwtAttSit►Q ROWALT Q SIN [- O MOLIS14 INSTALL (a RRPh1R Pllfr'P088D Var 8PR cow OTHERt TYAttCFt:DNStttUt!ttON BLWx FRAM 67M Dl6mpnONOPWORK \Ir0 $'Nro '" ue -MKiQ! tl4JtLWN4*p W C . SQ F(,*TA09 10 4M 8UIL0(NG# +tGO VALUATMOFTOTALCONSTFOUCTION S't'aMlwT ,A" =ELECTRICAL (;«-' AMP 8F.RVICE © PROOREBS ENERGY [,] W.R.E.C. =liMGW CAL it VALUATION OP MECHANCAL INSTALLATION C30AS ® ROOD Q SPWA*4TP Q OTW-ft FINISHED FLOOR ELEVATION$ I "17i y j'�p F4000 ZONE AREA (DYES NO ILf BUILORR C JAA0 t, .t�P,tR, CONNPANY f 1+LNiJC+c 51 dtLaA r1 S e.,1�t. W aK3NATWtC rumaTVM Lyl M P1119 GuRR0A i7V r r / AdAtnu .1r• kR�Ri tlaonee• try f 4�a°X► ltb7(gt=RAN COMPANY "� t� (�+• 81GNATURE - Ramemm FEtx Cal1CIiEh Aaarrrs b'" S to uconee s 3(0 CWPAW Au SONA7tlF1G NE6leTf ID rdll"ouaRrA YIN 1 Addrae I IV "''''''�( �•�• MkCHANI"k ..� CWPANY UA StOH i e t,TURE RE9t4TEMIS r N eta n } --X-) mdma =�� t t OMER COMPANY GMWATUIM RtCnFY4Ra0 m Wxm Lyf Adorn Llama@ M��•_•n_ I 4 tttt11t1[ 1 !#ll#! ( (ttlitttttlltt# Itii ! !1 ! ( tf ## tttEttt(littittltitl#tt Rl6rCAMIAl. Atlarh(2)PM Plorw;M re4 bf 9ulldirm Pkno,(1)eat of Bnsw Forme;ROW Porm)for now boaalRl (0, At1i#ptutm ten(!tl}vroNCna dtya aAot suernittrN dote.Required bnolti,Conattucttan Ftsae.8tamn�tatarPJrmi ud 88t Frnca Gieletted, Sae1WY F"M18e 8!dumptlor;BNIa Work PePM for rubmwela ull"p lWv OWME MAL Atler?l t2}aosslpltte ter.of I3a31dutg Pant plot a rite Straly Papal(ty sat kaatgy Forma R.0.1N Petmlt for nmv mru3Wauan N#nlmuml4+l(10?warkhDWeleldNraub�lllttildste.Requl�dolnito.CautrutUonPfmt►,8totmWtRarPlenewlSAlFtlxekfaRei�a StN�Ny Fadthtea t►t dtrMpthr.Bite WOAI Patsrdt tome newpra}atXt.AA t�ommfnandaN taqukwmonGt must meet tdblpliahca sioNPR'RMNT Nlara►(QytrlrrtEnylnearadPNma. "~RF}OPERT'fSUEiVEY regrRred iW'rif NEWaanattuatbn. l3irresRarNt: PN but sallcrlGm oomplowly. Ownsr3 Canuaot t4n bat k of eppTtottlan,nala+laed tr over$2606,a WOO*or ow"ftneatnaAl Is raqutrod, IAIC upamdar owr l7tiimi Agent(for the 0anlraclor)aftorofANam yprtheownaf}wowdbesamnbne01hn0wlredIsIWrlmmva►erewoftInpStitt" OARTHECOUNTERPEWTTINO (popybrconfir i agwred) Rwoara b emulbe Sewom Sw4cr Up Wafts APO FaneitiPlallSuneYlFoata4r} DAvewtW.NotvArCoumorHon puliftroedwnyt.,mwa ROW MO»9PQW'4[Mpaot7XRd00bwp WOPA4 WWMMORJQ R&mOA4wutpAafJ Musa w•B+40(lopm f Mov Wl1lM(aA1 vft GrtrX�kfu'i�iWloAdao) �NILfNfrtJ'1�11tpif�ff>1Nt>yano ' .kr.a�xpn#sru,�e`[+cy;AgMP�MkauaWnwa•LunaoPp�eatueN+vwlta�f�+CY1+)awndvoNoaryYovw►pl1s�+•M .. i0als;�e�WfuadROR� �utM�+Nlaew�u•�arua�poaAoN['aoe#+�p s::ffi ? �. a°'� ', "'tFk4t;.5':"::'!::',S '91nir3ri' :1 '•., ... �n : WON rZ.�nMi .i�►,RO :•11a '[olYiNilA�a M�N'ta J•fJ7Yl11Cti 1LapyA[ `alrld$W#&**,M W OVAO NM 1!�'+►{imkiKMSuo41b•/i n0aN art•u>R�s +4Nt•11M1•�NB lflom7adouo" oM14•aL Mdlli�lR►wRal�a ''MId 1•a09'gMUO. Ma111 nt�owAlu+4R��•11t B+A OK(ol)U%vmvsm •+wpa�pwoon�wrAixuu aN►ga�. �+•u�e4 'il) rd �n+t�xfaapdevm�+a"Inm"W"tzltow 'Ip!asf+�wwod ��i�fi.�flGb�lA".�•�idumF t!•NAIP7d�l�•!A+[A 'pMt�+ch�•kA,l� ��so)!Y)Ids'wmtoNa+lQ�!!'g1PMpW�MMN�N�'bPfOi)4�1�O�4wItN1�! , aa�aM•O•b�+ad�33af••t`r�ldttypfR87�aa i�)iW�tod(d•4o•�r .. . '•GSS"•:•' •'';"M .. �l%�?�!��!'::1••l��?i���i��.'�#:tel3:Y:l:tM1�s�1N1��1i��?�"�e�t'41f11�1Gt,��''J'?I-'1�r•1'Y,i�1I��F(F�1 �+.tiwlyd�CdlfYtiiwY:7fls'IJIR�If*f'.i'c' # t7 wuppv Mil t !lit ortom" l .r" 05505ZI�L1TJ r+ n ra'��,�r t�asns• ..ogv�iaa�ats� "'PW :.,;;;..n _• ..�.= :s:_�TC. 9�iUE���("�pT� �$ �d ''Rn• !G,': .,�<.;i,��.J � .,''•��1Vy'„. ! ,u. 6.400 orl pyppy -me ARY1f1YDannt .. ,.¢at+-.�d!d" ... .. .,� lit Ai7'J3/• F "•?!!�..�x" ,, �. .R4�h¢!�Ti. �'�:'�1�. ':i: ON LOAM rd 20wm +� Qt�'log 9MMYAMILMODUCON810fa �� tfili(O ©attivgHdq [� eHldooa Ina d' Arm pAQWWMimcmd p s3�rn�dfry � '�w�fetraaia�] tNcPaNi bbV19rI� ttdfi r+ro y�.. : e a�rfr _ a p n. >afann do Noud++fao�o Talc 9Nnrtrd x96'te Nouanaa<iNOx�ldAt NiMLd rMvP� ifJC t[R t1p�c'sdppsd llAtd�!! 17v� fm1�4►Yr�u ( ] M r s, ©, �� "L'IS►p � of 000a.� -a►�,,. �•O1'1Q?tlVd flOiifttlWglfO 1 �d47 r O 1 i0l"'� 61 °ll^ RY6Cr ! �----="L '1. 'A �a7►71�1 auawr�.aNw•at�nawgs.•a ugwlr�y�•aJ�w "IVY -Yo'�O�t, r : ! 1V uPMk+�ipt�t �!a r_"-- i. +.awrw.aallar•uYo �7!'�t1 t'�; '�"Ppv+flu,�o t, 8 h$ - t.. i Na�nN�ae,wuu•p �� ' t "Usum tcoaaerofax.� lt�!iddl��l d$U!((�u loAID F40'd 1�ErI iq�?.b Bf.O�18rGi/pt) '" :wof� Z®01Z00 d E 6ullexiew Spew Z5:9 I 810Zf 80190 813-78MO20 City of Zephyrhills Permit Application Fax-813-780a21 Building Department Date Received ���C phone Contocl for Pennittin Owners Name LOi+�f OA CAL C.C 1 Owner Phone Numhar Owners Address Oo%J� Aa.0 J R.s. Owner Phone Number Foe Simple TdleholderNamc L00.ip(; E�ILAI- �b1P11( � Owner Phone Number Foe Simple W011older Address US LV� � 2 L1A,,w JOB ADDRESS -1LAeJ,0 '9WD ° 1 NS o Z P It LOT# SUBDIVISION i PARCEL ID#IDA'7.b-1%-0000-00100— 00 bt �L (OaTA1Nm FROM FROPEMN TAX NOTIM WORK PROPOSED NEW CONSTR 8 ADDIALT (_] SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE SFR Comm = OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK try o S-T o P, 'FLEE. SETA M , 'o rt-r 1E vETC P BUILDING SIZE W O To SO FOOTAGE HEIGHT O I-O►r BUILDING 1'53. VALUATION OFTOTAL CONSTRUCTION 100 o ST.rotwT�A'�' =ELECTRICAL $ AMPSERVICE = PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL s VALUATION OF MECHANICAL INSTALLATION ( t/ (5� �/ =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I Ck Ck mofjAiipFLOOD ZONE AREA =YES NO 1 %e BUILDER COMPANY wAVliRc(= 910o -rrs LL(- CMGs ES; 2 A.�N1 SIGNATURE REGISTEREDY! N I FEEcuRREn I YIN Address 1A� 1.. L - S-r.?FTf F �3,�1�03 License8 I aoc ELECTRICIAN COMPANY ' SIGNATURE REGISTERED I Y/ N FEE CURREn I Y/N Address License# 1 PLUMBER COMPANY mo-jr SIGNATURE �{.�(AC� , ` TREGISTERED Y.I� �I FEE CuaR !N 13(�L�^� Address U� N. \ �' �JtPI NcenseG SIGNAAlaCAL COMPANY SIGNATURE I YIN FEE cw:REn LILN Address License OTHER COMPANY SIGNATURE REGISTERED I YIN FEM CURREn I Y/N Address License S tlllllllllllllllllllllllllllllllllillllltltllllllllllllllllllllllll � RESIDENTIAL Attach(2)Plot Plans;(2)sets of SuldhRg Plans;(1)eat of Energy Forms;R-O-W Pemdt for noweonsWetisDn, Minimum ten(10)woridrg days after submitlal date.Required onsits,Construction Plans,Stormwater Plans vrl Sit Fence installed Sanitary Facilities&1 dumpster,Site Work Permit for subdnAsior slierge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms,R-O-W Permit for new Construction. Minimum ten(10)worldrg days after submittal date.Required onslte,Constnxtlon Plans,Stamlwater Plans w/Slit Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.AD commercial requcemeMs must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. DIreCtUons: Fig out app0cation completely. Owner&Contractor sign back of appilcatwn,notarized Ifevor$2SOO.a NoBcs of Commencoment Is requlmd. (AIC upgrades overSTt100) Agent(for the contractor)or Power of A@omry(for the owner)would be someone with notartzed letter from owner autho&g some OVER THE COUNTER PERMITTING (Copy of contract required) Reroofs if shingles Sewers Service Upgrades AIC Fences(Plot/Survey/Footage) Drivoways-Not over Counter Non public M26vrdys-needs ROW 813-700AO20 City Of Zephyrhills Permit Application Fax-813 4 80-002 1 Building Department Date Received Phone contact for Permitfin - T["F Owners Name Ti-OILII 1CAL C-L%%)%L, I Owner Phone Number - 1 80- O.'IL101 Owners Address o\. t7 MAUCT s ILE Owner Phone Number Fee Simple Titleholder Name LO0.%O EQ1t.Al. t.t.)rJtL OwnarPhoneNumber ^ '`1)Fee Simple Titleholder�A..ddress 2,&3 AP. -2- e-k,w L 2554 - JOB ADDRESS •r1+_Aob 9Wi 1' \ oNS LAD -Zee t LOTO SUBDIVISION PARCEL]DR "740^-�,'00010'00100- OO63 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED 6 NR9 CONSTR 8 ADDIALT SIGN Q = DEMOLISH INSTALL REPAIR PROPOSED USE SFR Comm OTHER TYPE OF CONSTRUCTION BLOCK Q1 FRAME STEEL DESCRIPTION OF WORK W O Sz o2 P- 0E S A N , ^MCI; LO MA BUILDING S17E W O T o - SQ FOOTAGE� HEIGHT 0 r r TI-fT rT' BUILDING 5 (U, O O VALUATION OF TOTAL CONSTRUCTION ' g•Q.(yt AlrjE 10 =ELECTRICAL S AMP SERVICE 0 PROGRESS ENERGY ENERGY Q W.R.E.C. =PLLtM1tBINGIr =MECHANICAL 1$ VALUATION OFMECHAN3CALINSTALLATION ' ' ) ( �cl�"-" l•� =GAS Q ROOFING Q SPECIALTY = OTHER ! (k S FINISHED FLOOR ELEVATIONS Ck Ck.11 FLOOD ZONE AREA =YES NO ` t BUILDER • /� /g COMPANYAL4sRLl✓ SSOC IgT�S 1-LC. ��1 SIGNATURE C 'yt�iAQL�['�• C'i,DK4t� nEGSTEREoI Y/ N rEEouRRER YIN Address 5 Dr;.tit."' Ma s - r•. ( C � 33"1 A 7� I.I.#I U0C rW '� ELECTAICfAN r�s �JC]bj l j COMPANY p'' SIGNATURE �tC.}....• P t•C LC> REGISTERED I YIN Fix CURREn Y I N • dress — t t Ad at MBER `i _a SIGNATURE1, ! i R. Y/N rEe c mRr n Y!N T't V Address License te COMPANY M42 SIGNATURE � REGIISTOMD I YIN FEE CLIRRa I Y/N �^'9 Address License 3C" nTHER COMPANY Allied Roofing, Inc. SIGNATURE I Y/N FEE Cl1RREN I YIN Address P.O. Box lk38,Tam a, 33684 Licensed 1 CCC049368 ,—. RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms R-O-W Pemmit for new construction, Minimum ten(10)uerking days after subndflal date-Required onsite,ConslntcYoo Plaits,Stormwaler Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Pemlft for subdivlsionsrarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-0-W Permit for newconslnmton. Minimum ten(10)working days after submittal dale.Required onsile,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for ell new projects.All Commercial requirements must meet compliance SIGN PERMIT Attach(2)set;of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. ..-. . . Fill out application completey- Owner&Contractor sign back or appRcation,notarized If over$29oo,a Notice of Commencoment is required. (A/C upgrades over$7600) Agent(for the contractor)or Power of Attorney(for the Omer)would be someone with notarized letter from Owner authorizing same OVER THE COUNTER PERMITTING (copy of contract requires Reroofs if slingles Sewers Service Upgrades AIC Fences(Plot/Survey/Footage) Driveways-Not over Counter If On public roadways..needs ROW ADDRESSING DEPARTMENT GIS /ADDRESSING PASCO COUNTY GOVT. CENTER 8731 CITIZENS DRIVE, SUITE 310 r NEW PORT RICHEY, FL 34654 • , Phone:(727)815-7154 http://pascocountyfl.net/ May 29, 2018 Welcome from the Pasco County Addressing Staff, Please be advised that the following 911 approved address has been assigned: Parcel: 04 26 21 0000 00100 0060 Address Number/Roadway Name: 36763 Eiland Boulevard Zephyrhills, FL 33542 "PLEASE NOTE: IF THIS ADDRESS IS FOR A CORNER LOT, OR IF THE SITE PLAN CHANGES AT A LATER DATE, THE ADDRESS IS SUBJECT TO CHANGE. IT .IS YOUR RESPONSIBILITY TO PROVIDE ADDITIONAL COPIES OF THIS RECEIPT WHEN NECESSARY. If you have any questions regarding your address, please feel free to contact me at: (727) 815-7154. Sincerely, Pam ?Pdr" Pam Walton Addressing/GIS Analyst Wallace&Associates-Two Story Free Standing 30,350sq ft Column El SQ. FEET PRICE MAIN OR LIVING: 30,350, $ 122.72 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: = $ - VALUATION $ 3,724,552.00 FEE SHEET $ 15,624.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 16,011.48 ELECTRICAL: $ 3,515.40 PLUMBING: $ 2,343.60 MECHANICAL: $ 1,640.52 SUB-TOTAL $ 23,511.00 it -0 • ( TOTAL $ 23,511.00 SEWER: $ 36,605.72 WATER: $ 11,673.76 IRRIGATION: $ - TOTAL: $ 48,279.48 WATER METER: $ 11733.95 2' IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 910.50 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 910.50 PUBLIC SAFETY IMPACT FEES POLICE $ 4,947.05 FIRE $ 5,311.25 5% $ 512.92 TOTAL: $ .10,771.22 SUB-TOTAL $ 85,206.15 PARK IMPACT FEESI na SIF'S: 100.0% $ - 1.0% $ . - TOTAL: na TIF'S: na 99% $ - 1% $ - TOTAL: $ 85,206.15 Jacqueline Boges From: Jacqueline Boges Sent: Thursday, June 28, 2018 2:06 PM To: Jacqueline Boges Subject: RE: two story building Thomas, After we ran the number of practitioners for the new site found that the water/sewer would increase so I am going to leave as indicated on the current fee sheet. F; Jackie Boges - - 813-780--0020 ext 3513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have." Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. From:Jacqueline Boges Sent:Tuesday,June 26, 2018 3:34 PM To: 'thomas@wallace-associates.com'<thomas@wallace-associates.com> Subject: RE:two story building Attachment see From:thomas(@wallace-associates.com <thomas@wallace-associates.com> Sent:Tuesday,June 26, 2018 9:53 AM To:Jacqueline Boges<iboges@ci.zephyrhills.fl.us> Cc: 'Charlene Franklin'<charlene@alliedroofingtampa.com> Subject: RE:two story building Jackie, The roofing contractor on FMC Eiland Blvd. is: Eugene Meckley Allied Roofing, Inc.;(813-875-2727) charlene@alliedroofingtampa.com 1 We have finalized the new building address: 36763 Eiland Blvd Zephyrhills, FL 33542 - Can you resend the fee breakout sheet. It was not attached Thank you for your assistance. Please let us know when the building permit is ready for pick up. Thomas M.LoCicero Senior Project Manager CGC#1522215 Wallace Associates,LLC 5435 M.L. King Jr. Street North St. Petersburg, FL 33703 Phone: 727-520-0700/Fax: 727-520-0789 Thomas@wallace-associates.com From:Jacqueline Boges<iboges@ci.zephyrhills.fl.us> Sent:Tuesday,June 26, 2018 9:12 AM To:thomas@wallace-associates.com Subject:two story building Good morning, I currently have subs signed onto the job for the two story building listed are; Suncoast Electric Southern Equipment Bayside mechanical Who will be doing the roof? I also need the address you probably will need to get that from addressing in Pasco 727- 815-7154 will not be able to use the existing address for market square. I also attached the fee sheet disregard previous one sent.As soon as I can receive the address I can place the plans in permit status and will be ready for pick up . Thank you M-3-780--0020 ext 3513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have." Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. 2 Jacqueline Boges From: Jacqueline Boges Sent: Friday, April 13, 2018 9:29 AM To: 'thomas@wallace-associates.com' Subject: plans reviewed Attachments: RO.,. dvc; addressing:pdf;contractor certificat:docx;'vuallace associates-market sq,,two storybuildin.g=30 350:s-q-ft-xls rya------------- Hello Thomas we have reviewed the plans and have no comments Kalvin mentioned if you could give us the#of practitioners that will be occupying the building along with the#hours per shift probably would make a difference in your water and sewer impact fees. Would you need a price for 3' meter or would you just use the 2'we gave cost for 2'which shows on plans as to what is needed, Kalvin said to ask if you would use 3' instead? need : Completed approval of site plan review Wallace business tax receipt and state license of license holder Subs MEP- make sure they are registered and if registered current in our system Row use permit application filled out You will need to get with addressing to retrieve another address for this building Permit for Site need to do a application I have attached the fee sheet for the project. Let me know if you have any additional questions. Thank you Thomas daekk Boges 9IJ-790-0020 ext 3513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed, a mere doctrine, but it is He Himself we have."Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. 1 -OLrVERI ARCHITECTS 2QI iTr 32707 US Highway 19 Palm Harbor, FL 34684 727.781.7525 • Phone 727.781.6623 • Fax www.oliveriarchitects.com Colo `'- Go Green. Please consider the environment before printing this email. CONFIDENTIALITY NOTICE:This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to which they are addressed. If you are not the intended recipient,you may not review, copy or distribute this message. If you have received this email in error, please notify the sender immediately and delete the original message. Neither the sender nor the company for which he or she works accepts any liability for any damage caused by any virus transmitted by this email. "Faith is the most powerful of all forces of humanity. And when you have it,nothing can get you down." From: Richard Joudrey [mailto:richard.joudrey avidgroup.com] Sent: Tuesday, February 27, 2018 7:01 AM To: Amir Yacoub; Terri March Cc: Joe Oliveri; thomas(-Owallace-associates.com; Chad Eichel (ceichel(cbfloridamedicalclinic.com) Subject: RE: 1525 - FW: Florida Medical Clinic Eiland Blvd. Project Amir: Are they saying to use our plans for the ROW work? Thank you, Richard Joudrey, P.E. Project Manager AVID Group° 2300 Curlew Rd.Ste 201 Palm Harbor, FL 34683 Phone: (727)789-9500 Ext. 144 Fax: (727) 784-6662 Cell: (727) 234-5642 Richard.Joudrey@avidgroup.com 4 www.avidgroup.com Tampa * Orlando DISCLAIMER OF t1A8111TY. A-2016�45®RVIIPAVID Group JAM].makes the clectronlrafty sEored data on W6 email avallable fox Informotion purposes only..No warranty tither Y e4ressed or impliad is made regarding afiE aetoraty or relWbility o1 this data.AVI D ie3erves the rlght to revise,update and iroprow .5 y_ its iiedto,4611Y stwed da:a Mthdut notke and'assum6 6o r4iwedibili[y for an);darn+jes"Ith may arfsr 3i t result of the use of ats iwj-.The erser agri ste uerlfy ttre_data in the erru+h to oseeiu6 its nttt aJ ylor tkr frig entled usa AViU makes es ery chart to e'nsuie this emoil Is►irui tree,ha-Awe AVID.osaurries no responsibility for domages eaiued by the instollatlon of thls 6M..Ok of. •'C.leli,aUng 25 years scndnZ the data on thli en rail Fndkdes Uhot the user ptttpts tl eL'm iov On.dlrroni. oua dlerts svl[h eagerness, enthvslasm and tonfidenoe: OPENING THIS EMAIL CONS MESAACCEPTANCEOFTHEAUOVECONDITIONS. From:Amir Yacoub [mailto:amir@oliveriarchitects.com] Sent: Monday, February 26, 2018 5:06 PM To: Richard Joudrey<richard.ioudrev@avidgroup.com>;Terri March<Terri.March @avidgroup.com> Cc:Joe Oliveri<ilo@oliveriarchitects.com>;thomas(@wallace-associates.com; Chad Eichel (ceichel@floridamedicalclinic.com) <ceichel@floridamedicalclinic.com> Subject: 1525- FW: Florida Medical Clinic Eiland Blvd. Project Richard, Please see below and attached from the city and advise. If you have any questions, please call. Thank You. Amir Yacouib Senior Project Manager amir(a)-oliveriarchitects.com ,y- A - - zz 7 32707 US Highway 19 Palm Harbor, FL 34684 727.781.7525 • Phone 727.781.6623 • Fax www.oliveriarchitects.com 5 ya ZEPHYRHILLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills,FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.: Plan No.: Contractor: Business Name: Billing Address: Business Address: Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Eduption,healthcare,De tentionBCorrectional Public Assembly,Business, schools, Storage,Mercantile and Churches ISIte P Industrial. no charge Sprinkler $50 Multi-Family/Commerclal up to 800 sq ft $ 24.00 Standpipes $50 arge$24.00 801-1,500 sq ft $ 34.52 Fire Pump $50 ❑i Plan Revisions DBL 1,501-2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 H10-25 Heads $50 5,501-7,500 sq ft' $ 187.52 Natural Gas $50 26 plus Heads $100 7,501-10,000 sq ft $ 262.52 Fuel Tanks-pertank $50 STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 11 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation' $25 Per Pump $100 30,001-40,000 sq ft $ 1,050.02 Controlled Bum(15da; $100 0 iFIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 H:0-25 Devices $50 60,001-80,000 sq ft $2.100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26 plus Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed until Flammable Application $50 Annual Wet $50 violations corrected) Waste Tire Storage $50 Anneal Dry $50 SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 Hydro Undergrounds $45 Generator>30 KW $100 Other $50 Hydrostatic Test $65 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Acceptance Test $45 per system Fumigation Tenting $50 E]:Hood/Ducts $50 Hydrant Flow $75 Torch PottApplied $50 OTHER Haz.Materials $50-Annual LP Installation pertank $50 FIRE ALARM SYSTEM Fuel Tank Installation $50 System Acceptance $50 (Per Tank) $50 HRecall Acceptance $50 Natural Gas Installation $50 OTHER (Per System) Fire Wall/Smoke Wall $15 per wall ❑'Spray Booth $50 LP Gas $25 per tank Natural Gas $25 per system Tent 10k00'or greater $15 pertent Fire Pump $45 Fire Suppression $30 System Acceptance Exhaust Hood/Duct $30 Re-inspection DBL (other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS TOTAL R's)INSPECTION TOTAL PERMIT TOTAL= GRAND TOTAL Comments: Date: Inspector: nm I 1.ttif f alml �' I ��I [�,061GH.wC)F1W NEFIBNL _ I I p COx ' � j' (Br An01 SXAam OSE PAM o m m 1 Su10`6pOW r MATCNDNP P;,, •••� ' STA.OW0.00 •i .. a I I on-—Pout [ wESi!tiP,0 EwsfAmP ! AyP N p�op"�) f , Ppoo- o PROPOSED Ano7161E.1 FAMILY MEDICAL CENTER �! r I (BY AVID) )I , I i �o ----------------- ki �i I i— i�✓�P�,E_»�[,�E PAM t01 wAYN E 471 I � RYYwAY P�nJ : I COKME EmEW.W� }} �1D61GS,INC — CBD REAL ESTATE INVESTMENT,LLC r� CITY OF ZEPHYRHILLS SIMONS ROAD EXHIBIT fi[ Wallace&Associates-30,350 sq ft Column Es SQ. F PRICE MAIN OR LIVING: 30 350 $ 122.72 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: VALUATION $ 3,724,552.00 FEE SHEET $ 15,624.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 16,011.48 ELECTRICAL: $ 3,515.40 PLUMBING: $ 2,343.60 MECHANICAL: $ 1,640.52 SUB-TOTAL $ 23,511.00 public art 1%1 $ 235.11 TOTAL $ 23,746.11 SEWER: $ 36,605.72 WATER: $ 11,673.76 IRRIGATION: $ - t TOTAL: $ 48,279.48 WATER METER:1 $ 1,733.95 2'meter IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 910.50 INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ 910.50 PUBLIC SAFETY IMPACT FEES jn/a POLICE 1 FIRE TOTAL: $ _ SUB-TOTAL $ 74,670.04 PARK IMPACT FEES n/a SIF'S: n/a 100.0% $ - 1.0% $ TOTAL: $ - T I F'S: n/a 99% $ - 1% $ - TOTAL: $ 74,670.04 RLU UIUU m City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 13 roos Permit Type: r Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Illlli IIIII I IIII Ilill IIIII IIII IIIII Illli IIIII IIIII IIII IIII 2018089439 Permit No. Parcel ID N0 04-26-21-0000-00100-0062 N Rcpt:1960919 Rec: 10.00 NOTICE OF COMMENCEMENT DS: 0.00 IT: 0.00 State of Florida County of Pasco 05/29/2018 L. K. , Dpty Clerk THE UNDERSIGNED hereby gives notice that improvement Wit be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided In this Notice of Commencement: 1. Description of Property: Parcel Identification No._04-26-21-0000-00100-0062 Street Address: Pending; Intersection of Eilarid Blvd. &Simons Road 2. General Description of Improvement Construction of a two story,free standing,single tenant medical office building with full site development 3. Owner Information or Lessee information if the Lessee contracted for the improvement: FMC Eiland, LLC 2150 Via BelfggBlvd Land.O Lakes FL Address City State Interest in Property: Fee Simple Name of Fee Simple Titleholder: NSA (If different from Owner listed above) Address Charles Adair City State 4. Contractor: 5435 D901M. L. King Street,North St. Petersburg FL Address 727-520-0700 city J3 o State Contractor's Telephone No.: 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: _pAJLA S.O'NE I L,Ph.D.PASCO CLERK & COMPTROLLER s. Lender: 2 NIA 05 29 2018 03:29pm PG Hof 1 Nam 9`�31, 26 Address City Slate Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Chad A. Eiehel Name 2150 Via Bella Blvd Land O Lakes FL Address Telephone Number of Designated Person: - (813)712-1384 x24026ty Slate S. In addition to himself,the owner designates or to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration dale of Notice of Commencement(the expiration dale may not be before the completion of construction and final payment to the contractor,but unit be one year from the dale of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ,ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES,'AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoin notr of mmencement d Ihat the facts staled therein are true to the best of my knowledge and belief. STATE OF FLORIDA n �` COUNTY OF PASCO (; V 919DE o. caner or Lessee,or Own is or Lessee's Authorized Office r/Partner/Manager Signatory's Title/Office The foregoing instrument was acknowledged before me this�Y- day of ico,yr :S n�, l �n`iu; i as Ir 11e-l (type of aulhoriry,e.g.,officer,trustee,attorney in fact)for (name nt party on b half of om instrument was executed), Personally Known OR Produced Identification❑ Notary Signatures l L I UCLA I Type of Identification Produced Name(Print) \ a t U Ll PAMELA GOULD 1 Notify Public•State of Florida Commission M FF 997149 �,...... My Comm,Expires May 31.2020 wpdata/bcs/nolice cemme ncertient_pc053048 City of Zephyrhills Water and Sewer Impact Fee Calculation Land Use Type: Office No. of Square Feet 30353 Impact Fees Within City Limits Outside City Limits Water Distribution System $ 11,673.76 $ 14,592.20 Wastewater Collection System $ 23,464.27 $ 29,330.29 Wastewater Treatment Plant Capacity $ 13,141.45 $ 16,426.86 TOTAL $ 48,279.48 $ 60,349.35 c 4m,- <S 3 ,ti . ..City of:Zephyrhills W ater and Sewer Impact Fee Calculation Land Use Type: :Doctor or. Dentist Office . No.of Practitioners.' 11 N o. of.Employees per 8hr Shift. mpact Fees . Within City Limits.. Outside City Limits;: Water Distribution System $ 14,568:18 18,210.23 Wastewater Collection System. $ 2%282:05 $ : 36,602.50. Wastewater Treatment Plant Capacity ' $ : .1.6;399.77 $. : 20,499.77: :" TOTAL $ '60-250;00 $ 751-312.50 - From:thomas@wallace-associates.com [mailto:thomas@wallace-associates.com] Sent:Thursday, February 22, 2018 1:54 PM To:Audrey McGuire<AMcGuire@ci.zephyrhills.fl.us> Cc:Todd Vandeberg<tvandeberg@ci.zephyrhills.fl.us>; Chad A. Eichel<ceichel@floridamedicalclinic.com>; 'Amir Yacoub'<amir@oliveriarchitects.com>; Chuck Adair<chuckadair@wallace-associates.com>; Buddy Cole <buddycole@wallace-associates.com> Subject: Florida Medical Clinic Eiland Blvd. Project Audrey, To follow up with my submittal on Tuesday, see the attached requested documents for the FMC Eiland Blvd. Project. Please advise on an estimated review duration before we can submit plans to the Building Department. The site permit for this project has already been issued to the Avid Group, Richard Joudrey. Give me a call with any questions. Thank you. Thomas M. LoCicero Senior Project Manager CGC#1522215 Wallace Associates, LLC 5435 M.L. King Jr. Street North St. Petersburg, FL 33703 Phone: 727-520-0700/Fax: 727-520-0789 Thomas@wallace-associates.com ---__. vJ �� _" Ga .... C9 � .. o � � G U d c'"` � �" Go Green. Please consider the environment before printing this email. CONFIDENTIALITY NOTICE:This email and any files transmitted with it are confidential and intended solely for the use of the individual or entity to which they are addressed. If you are not the intended recipient,you may not review, copy or distribute this message. If you have received this email in error, please notify the sender immediately and delete the original message. Neither the sender nor the company for which he or she works accepts any liability for any damage caused by any virus transmitted by this email. "Faith is the most powerful of all forces of humanity. And when you have it,nothing can get you down." From .Todd Vande_berg,_[mailto:tvandebera@ci.zephyrhills.fl.us] Sent:[Monday,_F_ebr_uary, 26`2018-5:02-PM To: thomasC wallace-associate'Yb ;Audrey McGuire Cc: Chad A. Eichel; Amir Yacoub; Chuck Adair; Buddy Cole; Bill Burgess; Shane LeBlanc Subject: RE: Florida Medical Clinic Eiland Blvd. Project Mr. LoCicero, Good afternoon. The site plan approval for this project has expired and hence will need to be revisited/approved by the City of Zephyrhills. The City has also taken over ownership/maintenance of Simons Road from Pasco County. The reforeTa-city-ROW-use-permit will be-required the_Simons Road-access-connectio�. The City also has an improvement plan with a cross section for the remainder of Simons Road that will need to be followed for the remaining section of Simons abutting the Florida Medical Center site. Please be advised that this cross section is different than what was original approved and will need to be modified accordingly. I have attached a copy of the cross section for the remainder of Simons Road. We can certainly work with you to expedite this change with you and get the plan reapproved. Please feel free to contact me should you have any questions. Sincerely, Zephyrhills . 2"'�iis T'odd-H. 1Tande Berg Director of Planning Planning Department City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 Phone: 813.780.0006 Fax: 813.780.0005 vandeberg@ci.zephvrhills.fl.us "It's not the Plan that's important.... it's the Planning" 6 Thank you, Richard Joudrey, P.E. Project Manager AVID Group' 2300 Curlew Rd.Ste 201 Palm Harbor, FL 34683 Phone: (727)789-9500 Ext. 144 Fax: (727)784-6662 Cell: (727)234-5642 Richard.Joudrev@avidgroup.com www.avidgroup.com Tampa * Orlando DISCt IMEROF11AMITY: 1991.2G16. riR�Up r AVID Group(AVID)makes the efectron1wRy stand data on ehu ernalt avaitable flan Inroromtion pur".ses op1y. No warranty either. erlpressei!or IrnpRed Is made,regarding the aecdraty or reliability of this data.AVID rtaervesthe right to revise,update and IM, ove its tlectronrrall l scared ifaia is itho tt naLKerid'assumsei na respartslbdily for atsy darti+gta ss4kh may brine as a result of the use dT its data.The'user agrees to verify ifie"a in'ahe ernaA to useertalo is omi?3eyfar the Intended use.AVID makes every effort to ensure thds'emall Is►iris tree,haN it AVID.DSSM8 no rtspansibility for dan;i get cafaed by the Installation of this data,.Use oT 'Celebrating is yesrc srMv a IMAM B on this errs l ind-reates that the user accepts the atiovb tonditiopi. .nur diems Wth'raggne s-, enthasfasmondconfWnie.' OPCNiNGTHIS MAIL CONSTIWISACCEPTAACEOFTAE ABOVE CON DITIONS. FromJTodd Vandeberg=[mailto fvandeber>;@ci�zephyrhills.fl.us] Sent Thursda-yMarch-01,2018 10:58_AMe� To:thoma"s@wallac ae ssociates.com; Richard Joudrey<richard.ioudrey@avidgroup.com>; 'Amir Yacoub' <amir@oliveriarchitects.com>;Terri March <Terri.March@avidgroup.com> Cc: 'Joe Oliveri'<ilo@oliveriarchitects.com>; 'Chad Eichel' <ceichel@floridamedicalclinic.com>; Bill Burgess <bburgess@ci.zephyrhills.fl.us>;Jacqueline Boges<iboges@ci.zephyrhilis.fl.us>;Audrey McGuire <AMcGuire@ci.zephvrhills.fl.us>; Rodney Corriveau <RCorriveau@ci.zephyrhills.fl.us> Subject: RE: 1525- FW: Florida Medical Clinic Eiland Blvd. Project Thomas, I spoke=with=the-Bu�ilding-department-and explained=to_tflem�th�at the FMC-site=plan_had--expired-and-the-issue of'simons Road now-being a=City Road and.that a City ROW use permit will be required._I told ti-e'Building Dept-that we=a e�ok with them moving forward with the Construction plan/ permit reviews. As mentioned in a prior email we just need to reissue a revised site plan with an amendment on the Simons Rd/drainage and we will need to issue a City ROW use permit. We can work with you folks to keep the project on schedule and get the amended plan approved upon completion. By this email I am copying the Building Dept folks to advise them of this information. Thanks, 2 Jacqueline Boges From: _Todd Vandeberg Sent: Thursday, March 1, 201810:58 AM To: thomas@wallace-associates.com; 'Richard Joudrey; 'Amir Yacoub; 'Terri March' Cc: 'Joe Oliveri'; 'Chad Eichel; Bill Burgess; Jacqueline Boges;Audrey McGuire; Rodney Corriveau Subject: RE: 1525-FW: Florida Medical Clinic Eiland Blvd. Project Thomas, I spoke with the Building department and explained to them that the FMC site plan had expired and the issue of Simons Road now being a City Road and that a City ROW use permit will be required. I told the Building Dept that we are ok with them moving forward with the Construction plan/ permit reviews. As mentioned in a prior email we just need to reissue a revised site plan with an amendment on the Simons Rd/drainage and we will need to issue a City ROW use permit. We can work with you folks to keep the project on schedule and get the amended plan approved upon completion. By this email I am copying the Building Dept folks to advise them of this information. Thanks, d1 Zephyrhills 7'oddd-H 1Tande Berg Director of Planning Planning Department City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 Phone: 813.780.0006 Fax: 813.780.0005 vandeberg@ci.zephvrhills.fl.us "It's not the Plan that's important.... it's the Planning" From:thomas@wallace-associates.com [mailto:thomas@wallace=associates.com] Sent:Thursday, March 1, 2018 10:35 AM To:Todd Vandeberg<tandeberg@ci.zephyrhills.fl.us>; 'Richard Joudrey'<richard.joudrey@avidgroup.com>; 'Amir Yacoub'<amir@oliveriarchitects.com>; 'Terri March'<Terri.March@avidgroup.com> Cc: 'Joe Oliveri'<jlo@oliveriarchitects.com>; 'Chad Eichel'<ceichel@floridamedicalclinic.com> Subject: RE: 1525-FW: Florida Medical Clinic Eiland Blvd. Project Todd, Are the site permit/plan renewal & ROW use permit releases required prior to the drawings being sent in for building department review? 1 Thomas M.LoCicero Senior Project Manager CGC#1522215 Wallace Associates,LLC 5435 M.L. King Jr. Street North St. Petersburg, FL 33703 Phone: 727-520-0700/Fax: 727-520-0789 Thomas@wallace-associates.com From:Todd Vandeberg [mailto:tandeberg@ci.zephvrhills.fl.us] Sent:Thursday, March 1, 2018 10:26 AM To: Richard Joudrey<richard.ioudrev@avidgroup.com>;Amir Yacoub<amir@oliveriarchitects.com>;Terri March <Terri.March @avidgroup.com> Cc:Joe Oliveri<ilo@oliveriarchitects.com>;thomas@wallace-associates.com;Chad Eichel (ceichel@floridamedicalclinic.com)<ceichel@floridamedicalclinic.com> Subject: RE: 1525- FW: Florida Medical Clinic Eiland Blvd. Project Richard, The exhibit is provided to show the cross section to the north to be replicated abutting the Florida Medical Clinic for the ROW use permit that will be required from the City. Thanks, � IrP+y s IV dw Ir 2030 Dodd H. 'Vande Berg Director of Planning Planning Department City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 Phone: 813.780.0006 Fax: 813.780.0005 vandeberg@ci.zephvrhills.fl.us "It's not the Plan that's important.... it's the Planning" From: Richard Joudrey [mailto:richard.loudrey@avidgroup.com] Sent:Thursday, March 1,2018 8:42 AM To:Amir Yacoub<amir@oliveriarchitects.com>;Terri March<Terri.March@avidgroup.com>;Todd Vandeberg <tandeberg@ci.zephvrhills.fl.us> Cc:Joe Oliveri<ilo@oliveriarchitects.com>; thomas@wallace-associates.com; Chad Eichel 2 v Jacqueline Boges From: Todd Vandeberg Sent: Thursday, March 1, 2018 11:37 AM To: Richard Joudrey;.thomas@wallace-associates.com;-'Amir Yacoub; Terri March; Charlie Potter Cc: 'Joe Oliveri;'Chad Eichel; Bill Burgess;Jacqueline Boges;Audrey McGuire; Rodney Corriveau Subject: RE: 1525-FW: Florida Medical Clinic Eiland Blvd. Project Richard, A city ROW use permit will be required and we want the cross section of Simons Road to be consistent with the cross section that I sent in an,earlier,email. These changes should be reflected on a revised engineered site plan. Thanks, ls 203V 7'odd H. 1Tande Berg Director of Planning Planning Department City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 Phone: 813.780.0006 Fax: 813.780.0005 vandebere@ci.zephyrhills.fl.us "It's not the Plan that's important.... it's the Planning" From: Richard Joudrey [mailto:richard.joudrey@avidgroup.com] Sent:Thursday, March 1, 201811:12 AM To:Todd Vandeberg<tandeberg@ci.zephyrhills.fl.us>;thomas@wallace-associates.com; 'Amir Ya"coub' <amir@oliveriarchitects.com>;Terri March<Terri.March@avidgroup.com>;Charlie Potter <Charlie.Potter@avidgroup.com> Cc: 'Joe Oliveri'<jlo@oliveriarchitects.com>; 'Chad Eichel'<ceichel@floridamedicalclinic.com>; Bill Burgess <bburgess@ci.zephyrhills.fl.us>;Jacqueline Boges<jboges@ci.zephyrhills.fl.us>;Audrey McGuire <AMcGuire@ci.zephyrhills.fl.us>;'Rodney Corriveau<RCorriveau@ci.zephyrhills.fl.us> Subject: RE: 1525- FW: Florida.Medical Clinic Eiland Blvd. Project Todd: I need to know if anything is required on our end. 1 (ceichel@floridamedicalclinic.com) <ceichel@floridamedicalclinic.com> Subject: RE: 1525- FW: Florida Medical Clinic Eiland Blvd. Project Todd: Does this exhibit indicate that we are following our plans for the southern portion of Simons Road? Thank you, Richard Joudrey, P.E. Project Manager AVID Group° 2300 Curlew Rd.Ste 201 Palm Harbor, FL 34683 Phone: (727)789-9500 Ext. 144 Fax: (727)784-6662 Cell: (727)234-5642 Richard.Joudrev@avidgroup.com www.avidgroup.com Tampa * Orlando DI�CL NIAER00IIA WI"M 1998 2415 Lsf��1�P' AVID Group[AWD]Ynakes the ereetronlratiy stored tfats on ehss eri.mir avalrable tar lnformation purposes only. No wyrranty tither �. :}"" ; o+cprdsedorlrnpriedlsiiiaele,reg�r8in6aF.earcur�eyorrclia3111tynfthtsdata.AVtDre3ervrs1iitrightttires+ise,updnteundi�srnye . its ticctra+rsirally stared date Mthosrt mike and aas(nrsg no rg'sroiWbility for,5mydaniagin whith may arise as a resuit nt the use of a."- 6rsdats.4h us roRrc`�ilavcrityfhed.+tdinthepri wllbascertolrs�tiotcii5tyfeYthBir�tendedils�.AVID me_kes 146rtta `' enwrrth s crnail is Yfrils free,hnvtcvr'r i1YJ0 ussUmcs nn vxsponsihiliey!ai damage's taiaed bV the Installation of this data.-Wt of 'Ccicbrating 25 yr�rs srriiiyr the'dMA on Ulls email indicates that tM Usgr oaepts the Taw:eendhrons. .. .. our dlenu with eagerness, e!t"sisirnandoin66ate.` Of ENINGTHISIMAItCONSTITUESACCEPTANCEOFTHEABOVECOPIPMONS. From:AmirYacoub [mailto:amir@oliveriarchitects.com] Sent:Tuesday, February 27, 2018 8:26 AM To: Richard Joudrey<richard.ioudrev@avidgroup.com>;Terri March<Terri.March @avidgroup.com> Cc:Joe Oliveri<ilo@oliveriarchitects.com>; thomasCa@wallace-associates.com; Chad Eichel (ceichel@floridamedicalclinic.com) <ceichel@floridamedicalclinic.com> Subject: RE: 1525- FW: Florida Medical Clinic Eiland Blvd. Project Richard, I am not sure, may be it is worth a phone call from you to get to the bottom of this. If you have any questions, please call. Thank You. Amir Yacoub Senior Project Manager amirna.oliveriarchitects.com 3 Jacqueline Boges From: Todd Vandeberg Sent: Sunday, July 1, 2018 8:17 AM To: Jacqueline Boges; Charlie Potter; thomas@wallace-associates.com Cc: James Harlow; 'Rene Gosselin' Subject: RE: Eiland Address FMC MOB Jackie, Yes,this is correct the applicant will not be officially connecting to Simons Road at this time until the City constructs Simons Road. Therefore we do not need to obtain a City ROW use permit at this time. Thanks, M W. _ Zephyrhills 3 iz Todd H 'Vandde Berg Director of Planning Planning Department City of Zephyrhills 5335 8th Street Zephyrhills, FL 33542 Phone: 813.780.0006 Fax: 813.780.0005 vandeberg@ci.zephvrhills.fl.us "It's not the Plan that's important.... it's the Planning" From:Jacqueline Boges Sent: Friday,June 29, 201811:12 AM To: Charlie Potter<Charlie.Potter@avidgroup.com>;thomas@wallace-associates.com;Todd Vandeberg <tandeberg@ci.zephyrhills.fl.us> Cc:James Harlow<james.harlow@avidgroup.com>; 'Rene Gosselin'<rene@wallace-associates.com> Subject: RE: Eiland Address FMC MOB The Row will not hold up picking up the permit. I just need to know from planning that it is not needed on their end. From:Charlie Potter<Charlie.Potter@avidgroup.com> Sent: Friday,June 29,201810:48 AM To:Jacqueline Boges<iboges@ci.zephvrhills.fl.us>;thomas@wallace-associates.com;Todd Vandeberg 1 Jacqueline Boges From: thomas@wallace-associates.com Sent: Wednesday, June 20,2018 4:07 PM To: Jacqueline Boges . Subject: RE: plans reviewed Attachments: NOC.pdf Jackie, Can you please confirm you have received all information needed in order to release the Building Permit? If not, please advise what is left outstanding. See the attached recorded NOC. See below in RED. Thomas M.LoCicero Senior Project Manager CGC#1522215 Wallace Associates,LLC 5435 M.L. King Jr. Street North St. Petersburg, FL 33703 Phone: 727-520-0700/Fax: 727-520-0789 Thomas@wallace-associates.com From:Jacqueline Boges<jboges@ci.zephyrhills.fl.us> Sent: Friday,April 13,2018 9:29 AM To:thomas@wallace-associates.com Subject: plans reviewed Hello Thomas we have reviewed the plans and have no comments Kalvin mentioned if you could give us the#of practitioners that will be occupying the building along with the#hours per shift probably would make a difference in your water and sewer impact fees. Would you need a price for 3' meter or would you just use the 2'we gave cost for 2'which shows on plans as to what is, needed, Kalvin said to ask if you would use 3' instead? need Completed approval of site plan review I am told this was released today. Wallace business tax receipt and state license of license holder Sent in—please confirm. Subs MEP-make sure they are registered and if registered current in our system I am told this is complete. Row use permit application filled out Not required—we do not have any ROW work within our project drawings.Simons Road work has been deleted. You will need to get with addressing to retrieve another address for this building Complete-36763 Eiland Blvd Zephyrhills, FL 33542 Permit for Site need to.do a application I am told this was completed today. I have attached the fee sheet for the project. Let me know if you have any additional questions. 1 Jacqueline Boges From: Jacqueline Boges Sent: Tuesday, June 26, 2018 9:12 AM To: 'thomas@wallace-associates.com' Subject: two story building Attachments: two story.pdf Good morning, I currently have subs signed onto the job for the two story building listed are; Suncoast Electric Southern Equipment Bayside mechanical Who will be doing the roof? I also need the address you probably will need to get that from addressing in Pasco 727- 815-7154 will not be able to use the existing address for market square. I also attached the fee sheet disregard previous one sent.As soon as I can receive the address I can place the plans in permit status and will be ready for pick up . Thank you dackie Boges 813-780-0020 ext 3513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed, a mere doctrine, but it is He Himself we have."Dwight L.Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. 1 Florida Building '0 e Sixth Edition 7): ,_Energy .Cariservation EnergyGauge SUinrriit FILCom-2Q'f7; Effective.:Date: Dec 31,.2011, IECC_2015.=;Total-Building.Performance Compliiarice.Option Check Lisa Applications for compliance with the Florida Building Code, Energy Conservation shall include- � This Checklist - The full compliance report generated by the software that contains the-project summary, compliance summary, certifications and detailed component compliance reports. i The compliance report must include the full input report generated by,the software as cprftlgous part of the compliance report. OR/Boxes appropriately checked in the Mandatory Section of the complaince report. MD01 FLORIDA, INC. 405 2nd Street South a Suite 0 Safety Harbor, Florida 34695 Engineering,Business No. 9204 EnergyGauge Summit@ Fla/Com-2017,TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy_Conservation IECG 2015-Total Building Performance Compliance Option 2/13/2019" Page.1 of 25 PROJECT SUMMARY Short Desc: FMC Description: Florida Medical Clinic (hwner: Florida Medical Clinic Addressl: Eiland Blvd.&Simon Road City: Zephyrhills Addressl: State: Florida Zip: 0 Type: Office Class: New Finished building Jurisdiction: ZEPHYRAILLS,PASCO COUNTY,FL(611600) Conditioned Area: 31284 SF Conditioned&UnConditionedArea: 31284 SF No of Stories: 2 Area entered from Plans 30976 SF Permit No: 0— Max Tonnage 21 If differeint,write in: EnergyGauge Summit®FWCom-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Gonservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 2 of 25 Compliance Summary Component Design Criteria Result Gross Energy Cost(in$) 21,894.0 24,503.0 PASSED LIGHTING CONTROLS PASSES EXTERNAL LIGHTING No Entry HVAC SYSTEM PASSES PLANT No Entry ' WATER HEATING SYSTEMS PASSES PIPING SYSTEMS : No Entry Met all required compliance from Check List? 6ROINA IMPORTANT MESSAGE Info 5009 -- -- --An input report of this design building must be submitted along with this I Compliance Report EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 3 of 25 CERTIFICATIONS I hereby certify that the plans nd I s covered by this calculation are in compliance with the Florida Energy Code . Prepared By: .G and tterson� Building Official: XAA Date: 3 �� Date: certify that this building is in compy n e h the FLorida Energy Efficiency Code 0 Own''e Agent: Date; If Required by Florida later; I hereby certify,(*)that the system design is in compliance with the_ Florida.Energy Efficiency Code Architect: Joseph Oliveri Reg No: 14028 Electrical Designer:'William Bitola Reg No: 59480 Lighting Designer: William Ritola Reg No: 59480 Mechanical Designer: Garland Patterson Reg No: 14175 Plumbing Designer: Garland Patterson Reg No: 22812. (`) Signature is required where Florida Law,requires design to.be performed by registered design professionals. Typed names and registration numbers may be-used where all releva_ nt information is contained on signed/sealed plans. FIL EnergyGauge.Summit@ Fla/Com-2017.TAM 20.17-1.0_Compliant Software.Effective Date: Dec 31,201.7 Florida Building Code,Sixth Edition(2017)-Eneirgy Conservation IECC 2015:Total Building Performance Compliance Opti6n- 2%13/2018 - Page-4-of 25 . 1 1 Project:FMC Title: Florida Medical Clinic Type: Office (WEA File:FL_TAMPA_INTERNATIONAL 'AP.tm3) Building End Uses 1)Proposed 2)Baseline Total 1,409.90 1,845.80 $21,894 $28,827 ELECTRIC ITY(MBtulkWh/$) 1,409.90 1,845.80 413094 540842 $21,$94 $28,827. AREA LIGHTS 337:90 362.90 99008 106338 $5,247 $5,668 MISC EQUIPMT 469.30. 469.30 . 137506 137506 .$7,288 $7,329 PUMPS&MISC 0.10 0.00 17 11 $1 $1 SPACE COOL 454.40 547.90 133131 160532 $7,056 $8,556 SPACE HEAT 1.30 . .. 3.60 .. 394 1051 $21 $56 . VENT FANS 146.90 462.10 43038 135404 $2,281- $7,217 Credits Applied: None PASSES Passing Criteria=24503 Design (including'any credits)=21894 Passing requires Proposed Building cost to be at most 85% of Baseline cost.This Proposed Building is 'at 75.9% Energy0auge Summit@ Fla/Com=2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec.31,2017 Florida Building Code,Sixth Edition(2017)-Energy.Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 5 of 25 S External Lighting'Comphance Description Category. Tradable? Allowance Area or Length ELPA CLP (W/Unit) or.No.of Units (W) (W) (Sgft or ft) None Project:FMC Title:Florida Medical Clinic Type:Office (WEA File:FL TAMPA WrERNATIONAL_AP.tni3) ' Lighting Controls Compliance Acronym Ashrae Description Area. Design Min Compli- ED (sq ft) CP CP ante PrOZol Spl 17 Office-Enclosed 31,284 9 4 PASSES - PASSES EnergyGauge Summit@ Fla/Com-2017.-TAM 2017-1.0 Compliant Software.Effective Date_.Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option. 2/13/1018 Page 6 of 25 Project:FMC Title:Florida Medical Clinic Type:Office (WEA File:FL TAMPA_INTERNATIONAL AP,tm3) € System Report Compliance PrOSyl System 1 Variable Air Volume No.of Units Packaged System 1 i Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria 1PLV Criteria fiance Cooling System Air Conditioners Air Cooled 252020 12.20 10.00 12.20 11.60 PASSES 240000 to-760000 Btu/h Cooling Capacity Heatinng.System Electric Furnace 61434 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 7650 0.50 1.12 PASSES System-Supply Variable Volume Air Handling Air Handler(Return)- 6800 0.50 1.12 PASSES System-Return Variable Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution Not in Check list- 6.00 .6.00 N/A System(Ret) Compliance Ignored PrOSy2 System 2 Variable Air Volume No.of Units Packaged System _ 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria fiance Cooling System :Air Conditioners Air Cooled 252020 12.20 10.00 12.20 11.60 PASSES 240000 to 760000 Btu/h Cooling Capacity Heating System Electric Furnace 54608 1.00 1.00 PASSES Air Handling Air Handler(Supply)- 7700 0.5.0 1.12 PASSES System-Supply Variable Volume Air Handling Air Handler(Return)- 6900 0.50 1.12 PASSES System-Return Variable Volume Air Distribution ADS System(Sup) 6.00 4.20 PASSES System(Sup) Air Distribution Not in Check list- 6.00 6.00 N/A System(Ret) Compliance Ignored PrOSy3 System 3 Variable Air Volume No.of Units Packaged System i Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria iPLV Criteria !lance Cooling System Air Conditioners Air Cooled 252020 12.20 10.00 12.20 11.60 PASSES 240000 to 760000 Btu/h Cooling Capacity EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2016-Total Building Performance Compliance Option 2/13/2018 Page 7 of 15 Project:FMC Title:Florida Medical Clinic Type:Office I (WEA File:FL TAMPA_MERNATIONAL_AP.tm3) f Water Heater Compliance I Description Type Category Design Min Design .Max Comp Eff Eff Loss Loss fiance Water Heater 1 Electric water heater <=12 [kW] 0.92 0.90 PASSES k PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick[in] Thick[in] [F] .SF.F] I I None 0 I . I EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 9 of 25 Mandatory Requirements (as applicable) Mandatory requirements uhrements compiled by US Department of Energy nergy and Pacific Northwest National Laboratory. Adopted with permission Topic Section component Description Yes NIA Exempt 7— T"I 5— Insulation C303.2 Envelope Below-grade wall'insulation installed per 0 11 manufacturers instructions. Insulation C303.2 Envelope Slab edge Insulation installed per manufacturer's El Q instructions. Insulation C303.2 Envelope Above-grade wall Insulation installed per ❑ ED manufacturer's instructions. Insulation C402.3 Envelope High-atbeldo roors satisfy one of the following: 3-year-aged,solar reflectance—0.55 and thermal emittance—0.75 or 3-year-aged solar reflectance index>=64.0. 13 0 Fenestration C402.4.4 Envelope U-fa6tor of opaque doors associated with the building thermal envelope meets requirements. SYSTEM—SPECIFIC C403.2.12.1 Mechanical HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM SPECIFIC C403.2.12.2 Mechanical HVAC fan motors not oversized beyond allowable ❑ limits. SYSTEM—SPECIFIC C403.2,3(8)Table Mechanical Heat Rejection Equipment:Minimum Efficiency Requirement meet those listed in Table 0 0 C403-2.3(8) HVAC C403.2.7 Mechanical- Exhaust air energy recovery on systems meeting 0 &,o Table C403.2.7(1)and C403.2.7(2). SYSTEM—SPECIFIC C403.3 Mechanical Air economizers provided where-required,meet 11 the requirements for design capacity,control signal,ventilation controls,high-limit shut-off, integrated economizer control,and provide a means to relieve excess outside air during operation. SYSTEM—SPECIFIC C403.3.2 Mechanical Economizer operation will hot - I .increase heating 11 energy use during normal operation. SYSTEM—SPECIFIC C403.3A, Mechanical Water economizers provided where required, C403.3.4.1, meet the requirements for design capacity, C403.3.4.2, maximum pressure drop and integrated C4033.1 economizer control. VSTEM—SPECIFIC C403A.2.1 Mechanical Three-pipe hydronle systems using a common 0 e( 1:1 return for hot and chilled water are not used. SYSTEM SPECIFIC Q403.4.2.3.1 Mechanical Hydronic heat pump systems connected to a El r"'oe common water loop meet heat rejection and heat addition requirements. SYSTEM—SPECIFIC C403.4.3.4 Mechanical Open-circuit cooling towers having water cooled 13 �Ko chiller systems.,atid multiple or valrable speed condenser pumps,are designed so that tower SYSTEM SPECIFIC C404.2 Mechanical cells can run in parallel with larger of flow ortieria. Service water heating equipment meets efficiency ri requirements. Wattage, C405.3 Interior Lighting Exit signs do not exceed 5 watts per face, r '71 �in,, eview 2 rd-66--1 iWA&W Plan Review C103.2 y Envelope Plans and/or specifications l with which compliance can be determined for' the building envelope and%document where exceptions to the standard are claimed. EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Softare.Effective Date:Dec 31,2017 Florida Building Code',"Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 10 of 25 Plan Review C103.2 Mechanical Plans,specifications,and/or calculations provide all information with which compliance can be determined for the mechanical systems and equipment and document where exceptions to the standard are claimed. Load calculations per acceptable engineering st �❑ Plan Review 0103.2 Mechanical Plans,specifications,and/or calculations provide all information with.which compliance can be determined for the service water heating systems and equipment and document where exceptions to the standard are claimed. Hot water system sized per manufact Plan Review C103.2 Interior Lighting Plans,specifications,and/or calculations provide all information with which compliance can be E determined for the interior lighting and electrical if systems and equipment and document where exceptions to the standard are claimed. Information provided shoul Plan Review C103.2 Exterior Lighting Plans,specifications,and/or calculations provide 1 all information with which compliance can be determined for the exterior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. iiii Information provided shoul Insulation C402.2.5 Envelope Slab edge insulation depth/length.Slab insulation extending away from building is covered by pavement or>=10 inches of soil. Insulation C4o2.2.6. Project Radiant heating systems panels insulated to >=R-3.5 on face opposite space being heated. HVAC C402.2.6 Mechanical Thermally ineffective panel surfaces of sensible heating panels have insulation>=R-3.5. Insulation C402.2.6 Envelope Radiant panels and associated components, i designed for heat transfer from the panel surfaces to the occupants or indoor space are insulated with a minimum of R-3.5. Air Leakage C402.5.7 Envelope Vestibules are installed on all building entrances. Doors have self-closing devices. SYSTEM—SPECIFIC C403.2.12.3 Mechanical Fans have efficiency grade (FEG)>=67.The total efficiency of the fan at the design point of operation—15%of maximum total efficiency of the fan. ® —/ HVAC C403.2.13 Mechanical Unenclosed spaces that are heated use only radiant heat. HVAC C403.2.4.2 Mechanical Each zone equipped with setback controls using automatic time clock or programmable control system. SYSTEM—SPECIFIC C403:2.4.4 Mechanical Zone isolation devices and controls installed where applicable. SYSTEM_SPECIFIC C403.2.4.7 Mechanical Fault detection and diagnostics installed with. ® 2( 13 air-cooled unitary DX units having economizers. SYSTEM—SPECIFIC C403.2.5 Mechanical Hot water boilers supplying heat via one-or two-pipe systems include outdoor setback control. HVAC C403.2.6.1 Mechanical Demand control ventilation provided forspaces 0 El >500 ft2 and>25 people/1000 ft2 occupant density and served by systems with air side economizer,auto modulating outside air damper control,or design airflow>3,000 cfm. SYSTEM—SPECIFIC C403A.1.1 Mechanical Hydronic and multizone HVAC system controls v( 0 0 I areVAV fans driven by mechanical or electrical — variable speed drive per Table C403.4.1.1. SYSTEM SPECIFIC C403.4.1.3 Mechanical Reset static pressure setpoint for DDC controlled VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM.SPECIFIC C403.4.2 Mechanical Temperature,reset by representative building loads in pumping systems for chiller and boiler systems>500,000 Btu/h. I i EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 11 of 25 SYSTEM—SPECIFIC C403.4.2"3.2.1 Mechanical Closed-circuit cooling tower within heat pump loop, have either automatic bypass valve or lower leakage positive closure dampers.Open-circuit tower within heat pump loop have automatic valve to bypass all heat pump water flow around the tower.Open-or cl ❑ ❑ SYSTEM—SPECIFIC C403.4.2.4 Mechanical Hydronic systems greater than 500,000 Btu/h designed for variable fluid flow. SYSTEM-SPECIFIC C403.4.2.5 Mechanical System turndown requirement met through ❑ 2(El multiple single-input boilers,one.or more modulating boilers,or a combination of single-input and modulating boilers. Boiler input between 1.0 MBtu/h and 5 MBtulh has 3:1 turndown ratio,boiler Input between 5.0 ❑ ❑ SYSTEM—SPECIFIC C403.4.2.6 Mechanical Chilled water plants,with multiple chillers have capability to reduce flow auto matically'through the chiller plant when a chiller is shut down. Boiler plants with multiple boilers have the capability to reduce flow automatically through the boiler plant SYSTEM—SPECIFIC C403.4.3, Mechanical Fan systems with motors>=7.5 hp associated C403.4.3.2 with heat rejection equipment to have capability to operate at 213 of full-speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. i/❑ ❑ SYSTEM—SPECIFIC C403.4.4.5 Mechanical Multiple zone HVAC systems have supply air temperature reset controls. SYSTEM—SPECIFIC C403.4.4.6 Mechanical Multiple zone VAV systems with DDC of individual zone boxes have static pressure setpoint reset controls. SYSTEM—SPECIFIC C404.2.1 Mechanical Gas-fired water-heating equipment installed in new buildings:where a singular piece of water-heating equipment=1,000 kBtu/h serves the entire building,thermal efficiency—90 Et. Where multiple pieces of water-heating equipment serve the building wi SYSTEM—SPECIFIC C404.4 Mechanical All piping insulated in accordance with section details and Table C403.2.10. SYSTEM_SPECiFIC C404.5,C404.5.1, Mechanical Heated water supply piping conforms to pipe C404.5.2 length and volume requirements:Refer to section details. Or SYSTEM SPECIFIC C404.6.3 Mechanical Pumps that circulate water between a heater and storage tank have controls that limit operation from startup to—5 minutes after end of heating cycle. ❑ SYSTEM—SPECIFIC C404.7 Mechanical Water distribution system that pumps water from 11, a heated-water supply pipe back to the heated-water source through a cold-water supply pipe is a demand recirculation water system.Pumps within this system have controls that start the pump upon receiving ❑ Wattage C405.5.1 Exterior Lighting Exterior lighting power is consistent with what is shown on the approved lighting plarfs, demonstrating proposed watts are less than or equal to allowed watts. Plan Review C405.6 Project Group R-2 dwelling units have separate electrical meters. Plan Review C406 Project Plans,specifications,and/or calculations provide 12(13 all information with which compliance can be determined for the additional energy efficiency package options. SYSTEM—SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have means to balance and have pressure test connections. SYSTEM—SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have V(El means to balance and have pressure test connections. EnergyGauge Summit@)Fla/Com-2017.TAM 2017-1.0 Compliant Software"Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 12 of 25 insulation C303.1 Envelope Roof insulation installed per manufacturers€rMs ❑ instructions. Blown or poured loose-fill insulation is installed only where the roof slope is<=3 in 12. insulation C303.1 Envelope Building envelope insulation is labeled with ❑ R-value or insulation certificate providing R-value and other relevant data. Fenestration C303.1.3 Envelope Fenestration products rated in accordance with ® ❑ 13 NFRC. Fenestration C303.1.3 Envelope Fenestration products are certified as to performance labels or certificates provided. Insulation C303.2,C402.2.4 Envelope Floor insulation installed per manufacturer's instructions.Cavity or structural stab insulation installed in permanent contact with underside of decking or structural slabs. Insulation C303.2.1 Envelope Exterior insulation protected against damage, ❑ ® ❑ sunlight,moisture,wind,landscaping and equipment maintenance activities. insulation C303.2.1 Envelope Exterior insulation is protected from damage with a protective material.Verification for exposed foundation insulation may need to occur during Foundation Inspection. Insulation C402.1.3 Envelope Non-swinging opaque doors have R-4.75 insulation. insulation C402.2.2 Envelope Skylight curbs are insulated to the level of roofs o ❑ p with insulation above deck or R-5. ' Insulation C402.2.2 Envelope Insulation intended to meet the roof insulation t requirements cannot be installed on top of a suspended ceiling.Mark this requirement compliant if insulation is installed accordingly. Air Leakage C402.5 Envelope Building envelope contains a continuous air j barrier that has been tested and deemed to limit air leakage<=0.40 cfm/ft2. Air Leakage C402.5.1 Envelope The building envelope contains a continuous air ® ❑ 0 barrier that is sealed in an approved manner and either constructed or tested in an approved manner. Air barrier penetrations are sealed in an approved manner. Air Leakage C402.5.1.1 Envelope All sources of air leakage in the building thermal ❑ ❑ envelope are sealed,caulked,gasketed,weather stripped or wrapped with moisture vapor-permeable wrapping material to minimize air leakage. Air Leakage C402.5.1.2.1 Envelope The building envelope.contains a continuous air barrier that is sealed in an approved manner and material permeability<=0,004 cfmtft2. Air barrier penetrations are sealed in an approved manner. Air,Leakage C402.5.1.2.2 Envelope The building envelope contains a continuous air barrier that is sealed in an approved manner and average assembly air leakage<=0.04 cfmtft2. Air barrier penetrations are sealed in an approved manner. Air Leakage C402.5.2,C402.5.4 Envelope Factory-built fenestration and doors are labeled 0 as meeting air leakage requirements. ��11 Air Leakage C402.5.3 Envelope Where open combustion air ducts provide ® r rr--u El combustion air to open combustion fuel burning appliances,the appliances and combustion air opening are located outside the building thermal, envelope or enclosed in a room,isolated from inside the thermal envelope Air Leakage C402.5.5, Envelope Stair and elevator shaft vents have motorized 110 C403.2.4.3 dampers that automatically close. Air Leakage C402.5.5, Envelope Outdoor air and exhaust systems have motorized 11 C403.2.4.3 dampers that automatically shut when not in use and meet maximum leakage rates,Check gravity dampers where allowed. Air Leakage C402.5.6 Envelope Weatherseals installed on all loading dock cargo ® ® ❑ doors. EnergyGauge Summit@ Fla/Com-2017.TEAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 13 of25 Air Leakage C402.5.8 Envelope Recessed luminaires in thermal envelope to limit, infiltration and be IC rated and labeled.Seai between interior finish and luminaire housing. r HVAC C403.2.1 Mechanical HVAC systems and equipment design loads ❑ ❑ calculated in accordance with ANSI/ASHRAE/ACCA Standard 183 or:by an approved equivalent computational procedure SYSTEM_SPECIFIC C403.2.10 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab,verification may need to occur during Foundation Inspection. HVAC C403.2.3 Mechanical HVAC equipment efficiency verified: i SYSTEM_SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16.in.by 42 in. labeled for replacement only as per Footnote b to Table C403.2.3(3). SYSTEM_SPECIFIC C4032.4.1 Mechanical Heating and cooling to each.zone is controlled by a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. SYSTEM—SPECIFIC C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric resistance heat from coming on when not needed. HVAC C403.2.4.1.2 Mechanical Thermostatic controls-have a 5'A'F deadband. 00 HVAC C403.2.4.1.2 Mechanical Thermostatic controls have a 5 A°F deadband. HVAC C403.2.4.1.3 Mechanical Temperature controls have setpoint overlap restrictions: HVAC C403.2.4.2.1, Mechanical Automatic Controls:Setback to 55°F(heat)and C403.2.4.2.2 85°F(cool);7-day clock,2-hour occupant override,10-hour backup SYSTEM—SPECIFIC C403.2.4.2.3 Mechanical Systems include optimum start controls. HVAC C403.2.4.5, Mechanical Snowfice melting system sensors for future C403.2.4.6 connection to controls.Freeze protection systems have automatic controls installed. HVAC C403.2.6.2 Mechanical Enclosed parking garage ventilation has a11 El automatic contaminant detection and capacity to stage or modulate fans,to 5036 or less of design capacity. HVAC C403:2.9 Mechanical HVAC ducts and plenums insulated. Where ducts or plenums are installed in or under a slab, verification may need to occur during-Foundation Inspection. SYSTEM—SPECIFIC C403.2.9.1.3 Mechanical Ductwork operating>3 in.water column requires air leakage testing. SYSTEM—SPECIFIC C403.4.1.2 Mechanical. VAV fans have static pressure sensors located so controller setpoint—1.2 w.c.. SYSTEM SPECIFIC C403.4.2.2 Mechanical Two-pipe hydronic systems.using a common 0 El distribution system have controls to alloy✓a deadband>=150,F,allow operation in one mode for at least 4 hrs before-changeover,and have rest controls to limit heating and cooling supply temperature to< 30.OF. SYSTEM SPECIFIC C403.4.2.3.3 Mechanical Two-position automatic valve interlocked to shut off water-flow when hydronic heat pump with pumping system>10 hp is off. j SYSTEM—SPECIFIC C403.4.4.5,' Mechanical Zone controls can limit simultaneous heating and C403.4.4.5.1-4 cooling and sequence heating_ and cooling to each zone. SYSTEM—SPECIFIC C403.4.5 Mechanical Condenser heat recovery system that•can heat water to 85OF or provide 60%of peak heat rejection is installed for preheating of service hot water. SYSTEM—SPECIFIC C403.4.6 Mechanical Hot gas bypass limited to: < 240 kBtulh-50%capacity, >240'kBtu/h -25%capacity SYSTEM—SPECIFIC C404.3 Mechanical Heat traps installed on non-circulating storage water tanks. EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0.Compliant Software.Effective Date:Dec 31,2017 Florida Building Code;Sixth Edition(2017)-Energy.Conservation IECC 2015-Total Building Performance Compliance Option 2/012018 Page 14 of 25 j SYSTEM—SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge piping of non-circulating systems. SYSTEM—SPECIFIC C404.3 Mechanical Heat traps installed on supply and discharge piping of non-circulating systems. SYSTEM—SPECIFIC C404.6.1 Mechanical Controls are installed that limit the operation of a recirculation pump installed to maintain temperature of a storage tank.System return pipe is a dedicated return pipe or a cold water supply pipe. SYSTEM—SPECIFIC C404.6.1,C404.6.2 Mechanical Automatic time switches installed to automatically switch off the recirculating hot-water system or heat trace. SYSTEM—SPECIFIC C404.9.1 Mechanical Pool heaters are equipped with on/off switch and 11 El no continuously burning pilot light. SYSTEM—SPECIFIC C404.9.2 Mechanical Time switches are installed on all pool heaters and pumps. SYSTEM—SPECIFIC C404.9.2 Mechanical Time switches are installed on all pool heaters and pumps. SYSTEM—SPECIFIC C404.9.3 Mechanical Vapor retardant;pool covers are provided for heated pools and permanently installed spas. Controls C405.2.1 Interior Lighting Lighting controls installed to uniformly reduce the lighting load by at least 50%. Controls C405.2.1 Interior Lighting Occupancy sensors installed in required spaces. ❑ ❑ Controls C405.2.1. Interior Lighting Independent lighting controls installed per C405.2.2.3 approved lighting plans and all manual controls readily accessible and visible to occupants. Controls C405.2.2.1 Interior Lighting Automatic controls to shut off all building lighting installed in all buildings. Controls C405.2.3 Interior Lighting Daylight zones provided with individual controls that control the lights independent of general area lighting. Controls C405.2.3, Interior Lighting Primary sidelighted areas are equipped with C405.2.3.1, required lighting controls. C405.2.3.2 Controls C405.2.3, Interior Lighting Enclosed spaces with daylight area under C405.2.3.1, skylights and rooftop monitors are equipped with C405.2.3.3 required lighting controls. Controls C405.2.4 Interior Lighting Separate lighting control devices for specific uses installed per approved lighting plans. Wattage C405.2.4 Interior Lighting Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. Controls C405.2.5 Exterior Lighting Automatic lighting controls for exterior lighting installed.Controls will be daylight controlled,set based on business operation time-of-day,or reduce connected lighting>30%. Wattage C405.4.1 Interior Lighting Interior installed lamp and fixture lighting power Is consistent with what is shown on the approved lighting plans,demonstrating proposed watts are less than or equal to allowed watts. Mandatory Additional C406.4 Project Enhanced digital lighting controls efficiency package:Interior lighting has following enhanced lighting controls in accordance with Section C405.2.2: Luminaires capable of continuous dimming and being addressed individually,—8 luminaires controlled in Mandatory Additional C406.6 Project Dedicate outdoor air system efficiency package: Buildings with hydronic and/or multiple-zone HVAC systems are equipped with an independent ventilation system designed to provide>_ 100-percent outdoor airto each individual occupied space,as specified by Energypauge Summit(D Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 15 of 25 Mandatory Additional- C406.7,C406.7.1 Project Enhanced Service Water Heat System efficiency package_One of the following SWH system enhancements must satisfy 60 percent of hot water requirements;or 100 percent if the building, otherwise complies with heat-recovery per Section C403.4.5:Waste heat re HVAC C.408.2.2.1 Mechanical Air outlets and zone terminal-devices have means for air balancing. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means for air balancing. Testing C4082.3.2 Mechanical HVAC control systems have been tested to ensure proper operation;calibration and adjustment of controls. Pr.,rQe.. - : tTo }1�leoi ��erti i a f.0 G Post Construction C303.3,�C408.2.5.2 Interior Lighting Furnished O&M instructions for systems and ❑�❑$i❑ equipment to the building owner or designated representative. Post Construction C303.3,C408.2.5.3 Mechanical Furnished O&M manuals for HVAC systems ® ❑ 0 within 90 days of system acceptance. Fenestration C402.4.2.2 Envelope Skylights in office,storage,automotive service, manufacturing,non-refrigerated warehouse,retail store,and distribution/sorting area have a measured haze value>'90 percent unless designed to exclude direct sunlight. Post Construction C408.2.1 Mechanical Commissioning plan developed by registered design professional or approved agency. Post Construction C408.2.3.1 Mechanical HVAC equipment has been tested to ensure ® ❑ 0 proper operation.. Post Construction C408.2.3.31 Mechanical Economizers have been tested to ensure proper 11 ❑ 11 operation. Post Construction C408.2.4 Mechanical Preliminary commissioning report completed and certified by registered design professional or 'approved agency. Post Construction C408.2.5.1 Mechanical Furnished HVAC as-built drawings submitted a within 90 days of system acceptance: Post Construction C408.2.5.1 Interior Lighting Furnished as-built drawings for electric power systems within 90 days of system acceptance. Post Construction C4082.5.3 Mechanical An air and/or hydronic system balancing report is provided for HVAC systems. Post Construction C408.2.5.4 Mechanical Final commissioning report due to building owner within 90 days of receiptof certificate of occupancy. Post Construction C408.3 Interior Lighting Lighting systems have been tested to ensure proper calibration,adjustment,programming,and operation. EnergyGauge.SummitO Fla/Com-20.i.T TAM 2017-1A Compliant Software.Effective Date:Deo 31,2017 iii Florida Building Code,Sixth Edition(2017)-Enetgy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 16 of 25 Input Data Report �I Project Information Project Name: FMC Project Title:. Florida Medical.Clinic Address; Eiland Blvd.&Siuion'Road State Florida Zip: 0 Owner: Florida Medical Clinic" Buflding.l j pe: Office Building 0assificatiion: New.Finished building No.of Stories: 2 GrossArea(SF): 31,284 Bldg.Rotation: None Zones No Acronym. Description Type Area Multi Total Area [s [sf! i I PrOZol Zone 1 CONDITIONED 31284.0 1 31284.0 E] 1 a t 9 Spaces No Acronym Description Type Depth Width, HeightMlult Total Total IN [ft] IN Area Vol[cf] [sfJ In Zone: PrOZol 1 Pr0Zo,l Spl Offices Office-Enclosed % 176.00 177.75 10.00 1 31284.0 312840.0 Lighting No Type Category No.of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: PrO7661Sp1 1 Recessed.Fluorescent- General Lighting 1 32329 32329 Occupancy sensor without 9 ❑ No vent Daylighting EnergyGauge Summit0 Fla/Com-W17.TAM 2017A.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building-Code,Sixth Edition(2017)-Energy"Conservation iECC 2015-Total,Building Perlormance Compliance Option 2/13/2018 Page 17"o£25 Walls (Walls will be rotated clockwise by building rotation value) No Description Type Width H(Effec)Multi Area Orient Cond- Heat Dens. R-Value [ft] [ft] plier [sf] ation uctance Capacity [lb/cfJ [h.sf.F/Btu] Btu/h.sLFl [Btu/sf.F] In Zone: PrOZol 1 PrOZo1Wal 4"Brick .177.75 10.00 2 1717.5 North 0.2180 17.695 80.01 4.6 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" GYP 2 PrOZo1Wa2 Brick 176.00 10.00 2 1760.0 South 0.2180 17.695 80.01 4.6 ❑ /8"CMU/3/4"ISO_ BTWN24"oc/.5" Gyp 3 PrOZol Wal 4"Brick 177.75 10.00 2 '1777.5 East 0.2180 17.695 '80.01 4.6 ❑ /8"CMU/3/4"ISO BTWN24"oc0" GYP 4 PrOZol%4 4"Brick 177.75 10.00 2 1777.5 East 6.2180 17.695 80.01 4.6 ❑ /8"CMU/3/4"ISO. BTWN24"oc/.5" Gyp Windows (Windows will be,rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hr sf F] IN [ft] plier [S fl In Zone: PrOZoI In Wall: Pr0Zo1Wa1 1 PrOZolWalWi1 North No 0.4700 0.45 -0.47 6.00 4.66 3 83.9 ❑ 2 PrOZol Wa]Wi2 North No 0.4700 '0.45 0.47 5.33 4.66, 3 74.5 ❑ In Wall: Pr0Zo1Wa2 2 PrOZolWa2Wi2 South No 0.4700 0.45 0.47 6.00 4.66 4 111.8 ❑ 3 PrOZolWa2Wil South No 0.4700 0.45 0.47 5.33 4.66 3 74.6 ❑ In Wall: Pr0Zo1Wa3 1 Pr0Zo1Wa3Wil East No 0.4700 0.45 0.47 6.00 4.66 11 307.6 ❑ 2 PrOZo1Wa3Wi2 East No 0.4700 0.45 0.47 5.33 4.66 2 49.7 ❑ 3 Pr0Zo1Wa3Wi3 East No 0.4700 0.45 0.47 3.00 7.00 4 84.0 ❑ In Wall: P07_41Wa4 I PrOZol%4Wi2 East No 0.4700 0.45 0.47 5.33 4.66 2 49.7 ❑ 2 PrOZo1Wa4Wil East No 0.4700 0.45 0.47 6.00 4.66 9 251.6 ❑ 3 PrGZo 1 Wa4Wi3 East No 0.4700 0.45 0.47 3.00 7.00 4 84.0 ❑ EnergyGauge Summit®Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-.Energy Conservation IECC 2015-Total Building Performance Compliance Option 2111/2111 'Page' 18 of 25 Doors No Description Type Shade? Width H(Effec) Multi Area Cond. Dens. Ht Cap. R IN [ft] plier [sf] [Btu/h.sf.F] [lb/cf] [Btu/sf. [h.sf.F/ F] Btu] In Zone: PrOZoI In Wall: PrOZo1Wa1 1 PrOZol WalDFI Solid core flush No 3.00 7.00 2 21.0 0.7600 16.00 0.75 1.32 C] In Wall: PrOZo1Wa2 I PrOZol Wa2DrI Solid core flush No 3.00 7.00 1 21.0 0.7600 16.00 0.75 1.32 [� In Wall: PrOZo1Wa3 I PTOZolWalDrl Solid core flush No MO 7.00 1 21.0 0.7600 16.00 0.75 1.32 0 Roofs No Description Type Width H(Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN [ft] plier [sf] [deg] [Btu/h.Sf Fl [Btu/sL F]]lb/cf][h.sf.F/Btu i In Zone: PrOZol i PIOZolRfI Shnn1/1/2"WD KOO 176.00 1 15664.0 0.00 0.0320 1.50 8.22 31.2 [ Deck[WD Truss/4" Batt/Gyp Brd Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multi- Area TotalArea [Btu/hr sf F] [ft] [ft] plier [Sf] [Sf[ In Zone: In Roof: EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Cade,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2113/20I9 Page 19 of 25 Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. R=Value [ft] [ft] plier [sf] [Btu/h.sf.F [Btu/sf.F] [lb/cf] [h.sf.F/Btu In Zone: PrOZO 1 Pr0ZoIF11 Concrete floor,carpet 176.00 89:00 2 15664.0 0.5987 9:33 140.00 1.67 ❑ and rubber pad EnergyGauge Summit@ Fla/Com-2017.TAM 2017-1.0 Compliant Software.Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total'Building,Performance Compliance Option 2/13/2018 Page 20 of 25 i . . \ EnergyQaugeSummit0FWCom'2)17 TAM 2O174D Compliant Software.Effective Date: Dec 31.2O17 Plant Equipment. Category Size Inst.NaEff. TPLV Water. Heaters W-Heater Description Capacity Cap.Unit VP Rt. Efficiency Loss 1, Electric water heater 50 [Gal] 5 [kW] 0.9200 [Efl [Btu/h] ❑ Ext-Lighting Description Category No.of Watts per Area/Len/No Control Wattage_ Lumin- Lumin- [sf/ft/Nol Type [W] aires aire Fi Piping No Type Operating Insulation Nomonal pipe Insulation Is Temp Conducthrity Diameter Thickness Runout? .11pl [Btu-in%h.sf:Fl [in] [in) Fenestration Used Glass Name Glass Type No.of Conductance SHGC. VLT Panes [Btu/h.sf.Fl ApLbWnd11 User Defined 2 0.4700 0.4500 0.4700 Energypauge Sumn N Fla/Com-2017.TAM 2017-1.0 Compliant Software:Effective Date:Dec 31,2017 Florida Building Code,Sixth Edition.(2017)-Energy Conservation,IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 22 of 25 Constructs Used Simple Massless Conductance Heat Cap Density RValue No Name Construct. Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] @.sf.F/Btu] 1004 Concrete floor,carpet and rubber No No 0.60 9.33 140.00 1.7 pad Layer Material Material Thickness Framing No. IN Factor 1 151 CONC HW,DRD, 140L8,41N 0.3333 0.000 ❑ 2 178 CARPET WIRUBBER PAD 0.000 ❑ Simple Massless Conductance Heat Cap Density RValue . No Name Construct Construct [Btu/h.sf.F] [BtWsf.F] [Ib/cfJ [h.sf.F/Btu] 1013 4"Brick/8"CMU/314"ISO No No 0.22 17.70 80.01 4.6 BTWN24" oc/.5" Gyp Layer- Material Material Thickness Framing No. IN Factor 1 86 BRICK,COMMON,41N 0.3333 0.000 ❑ 2 105 CONC BLK HW,8IN,HOLLOW 0.6667 0.000 ❑ 3 269 .7S" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD,1/21N 0.0417 0,000 ❑ Simple Massless Conductance Heat Cap Density RValue, No Name Construct 'Construct [Btu/h.sf.F] [BtuA LF] [lb/cf] [h.sf.F/Btu] 1023 Solid core flush Yes No 0.76 0.75 16.00 1.3 Simple Massless Conductance Heat Cap Density RValue No Name Construct Construct tu/h.sf F[B ] [Btu/sf.F] [Ib/cfJ @.sf.F/Btuj 1038 Shngl/1/2"WD Deck/WD Truss/9" No No 0.03 1.50 8.22 31.2 Batt/Gyp Brd Layer Material Material Thickness Framing No. IN Factor 1 81 ASPHALT-ROOFING,ROLL 0.000 ❑ 2 244 PLYWOOD, 1/2IN 0.0417 0.000 ❑ 3 12 3 in. Insulation 0.2500 0.000 ❑ 4 23 6 in.Insulation 0.5000 0.000 ❑ 5 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ EnergyGauge Summit@ Fla/Com-2017`TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conservation IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 24 of 25 i f a EnergyGauge Summit@ Fla1Com-2017.TAM 2017-1.0 Compliant Software.Effective Date: Dec 31,2017 Florida Building Code,Sixth Edition(2017)-Energy Conserv' ation'IECC 2015-Total Building Performance Compliance Option 2/13/2018 Page 25 of 25 STANDARD LOAD OUTPUTS Company Name: . 02-14-18 Block Load v1.0 Page 2 of 2 Zone Name: FMC FLRI NORTH COIL SELECTION PARAMETERS Coil temp enter = 76.6/ 64.7 Total sensible load 170, 765 Coil temp out =. 54.6/ 54 .0 Total coil load 225, 179 Specified room RH= 50% Resulting room RH = sill, ------------------------------------------------------------------------- Terminal air temp=55.0/110 .0 Degrees rotated 0 Supply fan static= 0 .50 No ceiling return Building U-factor= 0 .09 Mechanical Design ------------------------------------- ---------------------------------- 6W STANDARD LOAD OUTPUTS Company Name: 02-14-18 Block Load v1.0 Page 1 of 2 Zone Name: FMC FLRI SOUTH City Name TAMPA FLORIDA Weight - Wall: 30- Latitude (deg) : 28 (lb/S- qft) Roof: 40 Elevation (ft) : 35 Bldg: 30 Indoor -Summer: 74 F 50 RH Color - Wall : LIGHT -Winter: 75 F Roof: LIGHT ------------------- ---------------------------------------------------- TEMP TOTAL TONS RSH TONS CFM 1. JAN at 8 A.M. 61.2 12 .74 10.31 5,920 2 . FEB at 9 A.M. 71.2 14.09 11.08 6,3,62 3 . APR at 10 A.M. 78 .6 15 .70 11 .20 6,429 4. MAY at 2 P.M. 91.0 17 .23 11 .60 6, 663 5 . JUN at 5 P.M. 92 .0 18 .87 12 .51 7,183 6. AUG at 5 P.M. 93.0 19.08 12 .71 7,298 7. NOV at 11 A.M. 77.6 15 .56 11.31 6,492 Heating Load (Btuh) = 49,796 w/Infil.= 49,796 Airflow= 1,293 cfm --------------------------------------------------- -------------------- ORIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0.16 0.16 0 .16 0.16 0.03 Glass Fac. :0 .56 Lights Fluorescent? Y Shade Fac. :0 .56 Floors: I Length: 86 Width: 84 Height: 10 , Vent Air Percent: 14 ----------------------------------------- ------------------------------- Number of people = 80 Sensible people load = 19, 665 Total lights = 11,558 Lighting load 49, 311 Other electrical = 10, 836 Other electrical 36,983 Area of N glass = 0 North glass solar 0 E3 m� Area of 8 glass = 191 z . South glass solar 1, 089 -:!e(D Rq Area of 9 glass = 254 East glass solar 2 -374 C== 4 , Area of W glass = 199 West glass solar = 171564. 0:-5:cz 2 M Total glass area 644 Total glass solar 21, 007 - 0.9 2 n:U)- a Total glass trans. 6, 852 lRrn 0 t 'qEwm" Area of E . O Area of N wall 860 N wall load 2 7152 j M 2 Area of S wall 669 S wall load 2Y532 wall 586 E wall load 3- 940 N8) Area of W wall 641 W wall load 3, 740 p Ln 0 La Total wall area 2, 756 Total wall trans. 10, 964 Area of roof = 7,224 Roof load = 7, 722 Safety factor = 01 Safety load 0 W i Supply fan hp 1.04 Fan heat gain (DT) = 3,204 <ZD Ventilation cfm 939 Vent sensible load 19,628 _r :, z: Cn Vent latent load 37,101 < ::E People latent load 16,455 < - LLJ Total cfm-std air= 7,298 Total latent load 53,556 0 = (D LLJ Room sensible 152, 526 Room latent 16,,455 < Plenum return exhaust credit = 0 < GRAND TOTAL LOAD 228, 913 Btu/hr or 19.08 tons <-- CO Q < z 0 Load tun for # 6. AUG at 5' P-M. Area (sq ft) = 7,224 Sq ft/ton 379 10 Total cfm-std air= 7,298 Cfm/sq ft 1.01 HEATING LOAD ------------------------------------------------------------------------- Ventilation load = 41,321 Roof heating load = 8, 669 Glass heat load = 14,426 Wall heating load 17, 638 STANDARD LOAD OUTPUTS Company Name: - - - 02-14-18 Block Load vl.0 Page 2 of 2 Zone Name: FMC FLR1 SOUTH COIL SELECTION PARAMETERS Coil temp enter = 76.4/ 64.5 Total sensible load = 175,357 Coil temp out = 54 , 6/ 54.0 Total coil load = 228, 913 Specified room RH= 5001 Resulting room RH = 510-. ------------------------------------------------------------------------ Terminal air temp=55.0/110 .0 Degrees rotated - 0 Supply fan static= 0 .50 No ceiling return BuildingU_factor_-- _------- -0.10MechanicalDesign- ------------ ---------- i I j ,I 6W STANDARD LOAD OUTPUTS Company Name: 02-14-18 Block Load v1.0 Page 1 of 2 Zone Name: FMC FLR2 NORTH City -Name TAMPA *, FLORIDA Weight - Wall: 30 Latitude (deg) : 28 (lb/sqft) Roof: 40 Elevation (ft) : 35 Bldg.: 30 Indoor. -Summer: 74 F 50 RH Color Wall: LIGHT -Winter: 75 F Roof: LIGHT --------------------------- TEMP TOTAL TONS RSH TONS CFM 1. JAN at S .A.M. 67.2 11.15 8_'82 5, 061 2 . FEB at 9 A.M. 71.2 12-.29 9 .36 5,376 3 . APR at 10 A.M. 78.6' , 14.53 10 .05 5, 769 4. MAY at 2 P_M_ 91.0 16.59 10.93 6,277 5 . TUN at 5 P.M. 92 .0 18 .26 11. 85 6, 804 6. AUG at 5 P.M. 93.0 18.30 11.89 6, 827 7. NOV at it A.M. 77.6 13 .53 9 .40 5,395 Heating Load (Btuh) = 51,415 w/Infil.= ' 51,415 Airflow= 1, 335 cfm ORIENTATION OF BUILDING N S E W RF TRANSMISSION FACTORS 0 .16 0.16 . 0.16 0.:16 0.05 f Glass Fac. :0 .5.6 Lights Fluorescent? Y Shade Fac. :0.56 Floors: 1 Length: 85 Width: 81 Height: 10 Vent Air Percent: 18 --- -------------------------------------------------------------------- ' Number of people = 77 Sensible people load = 18, 743 Total lights = 11, 016 Lighting load = 46, 997 Other electrical = 10,328 Other electrical = 35,248 Area of N glass = 162 North glass solar = 1, 110 Area of S glass = 0 South glass solar T 0 ��°�o Area of E glass 199 East glass solar = 1, 860 ;�54- Area of W glass = 112 West glass solar 9, 885 B az Total glass area = 473 Total glass solar 12, 855 D�oN Total glass trans. = 5, 033 Area of N wall = 688 N wall load = 2,202 OmQ 01 al of S wall = 850 S . wall load = 3,217 '� �;�,_ Area of E wall = 611 E wall load = 2,023 Area of W wall = 698 W wall load = 4,072 U N Total wall area = 2, 847 Total wall trans. = 11, 514 o�LS Area of roof = 6, 885 Roof load = 12,266 Safety factor = 0 a Safety load = 0 Supply fan lip = 0.98. Fan heat gain (DT) = 2,997 w¢ Ventilation cfm = 964 Vent sensible load = 20,146 ca Vent latent load = 38, 059 a < People latent load = 15, 683 Q Total cfm-std air= 6, 827 Total latent load = 53, 741 = o Room sensible = 142, 675 Room latent = 15, 683 C Plenum return exhaust credit = 0 Q Q J --> GRAND TOTAL LOAD = 219, 559 Btu/hr or 18 .30 tons <- m z v Load run for # 6 . AUG at 5 P.N . o J 0 Area (sq ft) = 6, 885 Sq ft/ton = 376 O O ao Total cfm-std air= - 6,827 Cfm/sq ft = 0.99 _ 0 J HEATING LOAD ------------------------------------------------------------------------ Ventilation load = 42,412 Roof heating load = 13, 770 Glass heat load = 10;595 Wall heating: load = 18,221 STANDARD -LOAD OUTPUTS Company Name: 02-14-18 Block Load v1.0 Page 2 ,of 2 Zone Name: FMC FLR2 NORTH COIL SELECTION PARAMETERS o Coil temp, enter = 76.7/ 64.7 Total sensible load 165,818 Coil temp out = 54.8/ 54.0 Total coil load 219,559 Specified room RH= so%- Resulting room RH '5106 ------------------------------------------------------------------------ Terminal air temp=55 .0/110 .0 Degrees rotated 0 Supply fan static= 0.50 No ceiling return Building U-factor= 0.10 Mechanical Design ------------------------------------- ---------------------------------- f STANDARD LOAD OUTPUTS Company Name: _ - _ —. _ A 02-14-18 Block Load v1.0 Page 2 of 2 Zone Name: FMC FLR2 SOUTH COIL SELECTION PARAMETERS Coil temp enter =' 76.4/ 64 .4 Total sensible load = 174,462 Coil temp out = 54.6/ 54 .0 Total coil load = 226, 198 Specified room RH= 50o Resulting room RH = 510 ------------------------------------------------------------------------ Terminal air temp=55.0/110 .0 Degrees rotated = 0 Supply fan static= 0 .50 No ceiling return Building U-factor 0 .11 Mechanical Design ---------------=-------------------------------------------------------- 1 I i I I �I I I I i I I I Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Tuesday, September 11, 2018 12:02 PM To: Jacqueline Boges Subject: [Request received] 36763i Eiland Blvd by#19892 4-4-Please type your reply above this line-4 Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated.One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS,reply to this email or click the link below: hqps://zgphyrhillsfl.zendesk.com/hc/requests/238918 ...................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges L.- ` Sep 11,9:01 AM MST irrigation meter 36763i Eiland Blvd by#1 9892 This email is a service from City of Zeph}shills Support. 1 CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT �� V� . 1-6 1 THIS JOB HAS NOT BEEN COMPLETED, The following additions or corrections shall be made before the job will be accepted. wag t4 SO,02 N� t�-- � It is unlawful for-any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION \orother material,unfll the proper inspector has had ample time to approve the installation. a y LOFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR �`�'1Zcng-,- 1J,-r T Gt' Nlc7�0►u� . Contractors Material and Test Cgrtificate for Aboveground Piping A.P'ocedure Upon completion of work,inspection and tests shall be mad by the-contractor's representative and b T "�`4ATK)KWrl witnessed by an owner's representative. All defects shall be correctgd and system left in service before contractor's personnel finally leave the job. A certif}rate shall be filled out and signed by both representatives. Copyes shall be prepared for approving authorities,owners and contractor. It is understood the owner's representative's signature in no way prejudices any Maim against contractor for faulty material,poor workmanship,or failure to comply with approving authority's requirements or local ordinances.All 'No"answers shall be explained in the Comments portion of this form. Property Name:FmC. Address: Date: %01 g 1/1tr O.Tests B.Plans 1. All piping hydrostatically tested at 20 psi for k hours 1. AFcepted by Approving Authorities(Na es):T I 2• Dry piping pneumatically tested C(Yes ❑No 2. Address: ! 3.Equipment operates properly Yes O No 3. Installation conforms to accepted plans es ❑No, 4. Do you certify as the sprinkler contractor that additives and 4.Efluipment used is approved Yes ❑Nd corrosive c}jemicals,sodium silicate or derivatives of sodium C.I tI uctions silicate,brine,or other corrosive chemicals were not us d for 1.H�s person in charge of fire equipment ben testing systems or stopping leaks? O Yes ❑No instructed as to location of control valves d cure and maintenance of this new equipm nt Yes ❑No 5. Drain Test: 2.Have copies of the following been left on he premises- a.Static pressure reading of gage located near water supply connection ?0 psi. a. ystem components instructions c4 es o No b. Residual pressure with b.Cure and maintenance instructions es o No valve in test connection open wide _sGO psi. c.r6TA 25 dyes ❑No- 6.Underground mains and lead in connections to D."' tion of system-Supplies building(s): risers flushed before connection made to sprinkler E.Sprinklers j piping and verified by copy of form No: 13-U Yes es ❑No M e Model Year Made Orifice uantity Temperatur 7.Flushed by installer of underground piping O No 8.If powder driven fasteners are used in concrete, has representative sample testing been satisfactorily completed? d/Yes ❑No P.Blank Testing Gaskets I. Number used: 2.Locations: 3.Number removed: j Q.Welded Pipijng-If welded piping was used in the system, F.Pipe and Fittings complete thei following: 1.T e of Pipe: V- yD 1.As the sprinkler contractor,were welding procedures in 2.Ty of Fittings: compliance with the requirements of at least AWS B2 , G.Al rm Valve or Flow Indicator ASME Section IX or other required standards C�Yes ❑No 2.Was welding performed by welders qualified in compliance with the requirements of at least AWS B2 SW' ASME Section IX or other required standards fd Yes ❑No Hq�4 Pipe Valve 3. Do you certi�y that welding was carried out in compliance Model and Serial Number: with a documented quality control procedure to insure that I.Quik Opening Device(Q.O.D.) all discs are retrieved,openings in pipe are smooth,slag and Mak ,Model and Serial Number: other welding residue are removed,the internal diameters of J.Dry-Pipe System Operating Test Without Q.O.D. piping are not penetrated,completed welds are free from cracks, incomplete fusion,surface porosity greater than 1/16 inch in I.Time to trip through test connection*: 2.W�ter pressure psi. Air pressure psi. diameter,undercut deeper than the lesser of 25%of the wall 3.Trip point air pressure psi. thickness or I1/32 inch,and the completed circumferen ial 4.Time water reached test outlet*: butt weld reinforcement does not exceeds 3) inch?( Yes Cl No 5.Alarm operated properly ❑Yes ❑No R.Cutouts(Disks) K.Dry-Pipe System Operating Test With Q.O.D. Do you certify that you have a control feature to �/ 1.Tirne to trip through test connection*: ensure that all cr touts(disks)are retrieved? Nes es ❑No 2. W ter pressure psi. Air pressure psi. S.Hydraulic Data Nameplate Provided ❑No 3.Trip point air pressure psi. 4.Ti e water reached test outlet*: T.Date left in service(with all control valves open): U.Signatures 5.Alarm operated properly ❑Yes ❑No 1.Name of sprinkler contractor: L.Deloge and Preaction Valves 2.Tests witnessed by: 1.M e&Model: For property;owner(Signed): 2. Operation: ❑Pneumatic ❑Electric O Hy raulic Title: LGGI- Sv 'T Date:f _i/f For sprinkler contractor(Signed�� &,� 3.Piping and detecting media supervised ❑Yes ❑No .� 4. Dos valve operate from manual trip and/o TitIe:�`ir� �''��'�- Date: Z-'� V.Comments(This section is for additional'explanation and notes. All remote control stations ❑Yes O No Wo"answers must be explained here.) 5.Is t ere an accessible facility in each cir -,re for testing ❑Yes ❑No 6. DoTs each circuit operate supervision loss alarm OYes 0 No - 7.Dogs each circuit operate valve release OYes ❑No `..z.-�� 8.M imum time to operate release: M.Pture Reducing Valve 1.Lo ation and Floor: 2.M e and Model: 3.Setting: Static Pressure: Inlet nsi, Outlet _ nsj 4.Residual Pressure(Flowing): Inlet psi, Outlet psi 5.Flow Rate: gpm N.Tesi Description Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi for two hours or 50 psi above static pressure in exc ss of 150 psi for two hours. Differential dry-pipe valve clappers shal be left open during tes'i ""��to prevent damage. All aboveground piping le age shall be stopped. xPneumatic: Establish 40 psi air pressure and m asure drop. Test pressure tanks at normal water level and air pre sure and measure air pressure drop. In both cases,the pressure drop hall not exceed 11/z psi in 24 hrs. I *Measured from the time the inspector's test co nection is opened ❑Check here if comments continue on the reverse side of this form ©2007 National Fire Sprinkler Association,40 on Barrett Road Patterson,NY 12563(845)878-4200 Form 13-A,Page 1 of 1 i �f.Cj1l Ci ��6C7C,,' W4T:Z - Contractors Material and Test Certificate for Aboveground Piping ,�.R A.Procedure Upon completion of work,inspection and tests shall be made by the-contractor's representative and ASS0CAT1D jw. witnessed by an owner's representative. All defects shall be corrected and system left in service before contractor's personnel finally leave the job.A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities,owners and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material,poor workmanship,or failure to comply with approving authority's requirements or local ordinances.All "No"answers shall be explained in the Comments portion of this form. Property Name: Frn C Address: 3 `uol E' Date: 0 U O.Tests B.Plans 1.All piping hydrostatically tested at 20 psi for_ , ours 1.Accepted by Approving Authorities(Names): ,� o� 7,, ,j Vvk1S 2.Dry piping pneumatically tested es Q No 2. Address: 3.Equipment operates properly Nes ❑No 3.Installation conforms to accepted plans dYes ❑No 4.Do you certify as the sprinkler contractor that additives and 4.Equipment used is approved ayes Q No corrosive chemicals,sodium silicate or derivatives of sodium C.Instructions silicate,brine,or other corrosive chemicals were not u ed for 1.Has person in charge of fire equipment been testing systems or stopping leaks? IYes 0 No instructed as to location of control valves and ff care and maintenance of this new equipment r3Yes ❑No 5.Drain Test: 2.Have copies of the following been left on the premises/ a.Static pressure reading of gage Yes Ss O No located near water supply connection 70 psi. a.System components instructions b.Residual pressure with b.Care and maintenance instructions a No valve in test connection open wide S::p psi. c.NFPA 25 s ❑No 6.Underground mains and lead in connections to D.Location of system-Supplies building(s): risers flushed before connection made to sprinkler f E.Sprinklers piping and verified by copy of form No. 13-U Vyes es 0 No Make Model Year Made Orifice Quantity Temperature 7.Flushed by installer of underground piping Q No 8.If powder driven fasteners are used in concrete, has representative sample testing been satisfactorily / completed? Q Yes ❑No Ca L QI Zvi-d I h lit t,S.s P.Blank Testing Gaskets 1.Number used: C1rL S-6ol 2vs t2 las I5S 2.Locations: 3.Number removed: Q.Welded Piping-If welded piping was used in the system, F.Pipe and Fittings complete the following: 1.Type of Pipe: 1.As the sprinkler contractor,were welding procedures in 2.Type of Fittings: compliance with the requirements of at least AWS 132.1, G.Alarm Valve or Flow Indicator ASME Section IX or other required standards a/Yes ❑No Tvne Make I Modn.] I May Time to Operate Tbronorh Insp.Test 2.Was welding performed by welders qualified in compliance with the requirements of at least AWS 132..)-, ASME Section IX or other required standards Q Yes 0 No H.Dry-Pipe Valve 3.Do you certify that welding was carried out in compliance Make,Model and Serial Number: with a documented quality control procedure to insure that I.Quick Opening Device(Q.O.D.) all discs are retrieved,openings in pipe are smooth,slag and Make,Model and Serial Number: other welding residue are removed,the internal diameters of J.Dry-Pipe System Operating Test Without Q.O.D. piping are not penetrated,completed welds are free from cracks, 1.Time to trip through test connection*: incomplete fusion,surface porosity greater than 1/16 inch in 2.Water pressure psi. Air pressure psi. diameter,undercut deeper than the lesser of 25%of the wall 3.Trip point air pressure ksi. thickness or 1/32 inch,and the completed circumferentIal 4.Time water reached test outlet*: butt weld reinforcement does not exceed 3/32 inch? ,es ❑No 5.Alarm operated properly QYes Q No R.Cutouts(Disks) K.Dry-Pipe System Operating Test With Q.O.D. Do you certify that you have a control feature to /' 1.Time to trip through test connection*: ensure that all cutouts(disks)are retrieved? O Yes ❑No 2.Water pressure psi. Air pressure psi. S.Hydraulic Data Nameplate Provided Cd Yes ❑No 3.Trip point air pressure psi. T.Date left in service(with all control valves open): 4.Time water reached test outlet*: U.Signatures 5.Alarm operated properly QYes ❑No 1.Name of sprinkler contractor: s`� � � L.Deluge and Preaction Valves 2.Tests witnessed by: 1.Make&Model: For property owner(Signed): �Ci 2,Operation: ❑Pneumatic ❑Electric ❑Hydraulic Titler''"'��'C t-r¢Gt�r9��' f "Op y r✓� T" Date: 3.Piping and detecting media supervised QYes Q No For sprinkler contractor(Signed): " . �i�.���i�.s Title: �sysT aC Date:,2 ::3/,r 4.Does valve operate from manual trip and/or V.Comments(This section is for additional explanation and notes. All remote control stations QYes 0 No "No"answers must be explained here.) 5.Is there an accessible facility in each circuit for testing QYes 0 No '�.0 S c' c 1-25't 6.Does each circuit operate supervision loss alarm QYes 0 No 7.Does each circuit operate valve release QYes 0 No 8.Maximum time to operate release: M.Pressure Reducing Valve 1.Location and Floor: 2.Make and Model: 3.Setting: Static Pressure: Inlet !psi, Outlet psi 4.Residual Pressure(Flowing):Inlet psi, Outlet psi r 5.Flow Rate: gpm N.Test Description Hydrostatic: Hydrostatic tests shall be made at not less than 200 psi for two hours or 50 psi above static pressure in excess of 150 psi for two hours. Differential dry-pipe valve clappers shall be left open during test to prevent damage. All aboveground piping leakage shall be stopped. Pneumatic. Establish 40 psi air pressure and measure drop. Test pressure tanks at normal water level and air pressure and measure air pressure drop. In both cases,the pressure drop shall not exceed 1'/z psi in 24 hrs. *Measured from the time the inspector's test connection is opened ❑Check here if comments continue on the reverse side of this form @2007 National Fire Sprinkler Association,40 Jon Barrett Road Patterson,NY 12563(845)878-4200 Form 13-A,Page I of I F„�- Contractors Material and Test ICe r tificate.for Aboveground Piping , , A.Procedure Upon completion of work, inspection and tests shill tt made by the-contractor's representative and witnessed by an owner's representative. All defects shall be cor ectcc and system)left in service before contractor's person iel finally leave the job.A certificate shall be filled out and signed by both representatives. Cop es shall be prepared for approving authorities,owner 3 and contractor. It is understood the owner's representative's signature in no way prej l dic any claim against contractor for faulty material,poor workmanship,or failure to comply with approving authority's requirements or local ordirianc . All "No"answers shall be explained in the,Comme its portion of this form. Property Name: FrvtG Address: 8 61 Da e: 1 t>/k f l k O.Tests B.Plans 1.All piping hydrostatically tested at 20P psi for Z- bours 1.Accepted by Approving Authorities(Names): -7-a whkkb 2.Dry piping pneumatically tested es ❑M 2.Address: 3.equipment operates properly Yes ❑.No 3. Installation conforms to accepted plans es Nc 4.Do you certify as the sprinkler contractor that additives and 4.Equipment used is approved Yes Q Nc corrosive chemicals,sodium silicate or dc rivatives of sodium C.Instructions silicate,brine,or other corrosive chemica s were not us d for 1. Has person in charge of fire equipment been instructed as to location of control valves and C testing systems or stopping leaks? Yes ❑No care and maintenance of this new equipment oyes LD N 5.Drain Test: a. 2. Have copies of the following been left on the premises:,, iStatic pressure reading of gage TOa.System components instructions [� s q N located near water supply connection psi. i b.IResidual pressure with b.Care and maintenance instructions es C]N valve in test connection open wide psi. c.NFPA 25 Yes Q No 6.Underground mains and lead in connectioris to D.Location of system-Supplies building(s): risers flushed before connection made to sprinkler /. E.Sprinklers piping and verified by copy of form No. 3-U OYes ElNo Make Model Year Made Orifice Quantity Tempeiritui 7.Flushed by installer of underground piping dyes Yes O No 8.If powder driven fasteners are used in con rete, G1L S(915 �l2\LS a aco has representative sample testing been sat sfactorily completed? Yes ❑No L �tyo ��a o2p lss P.Blank Testing Gaskets 1.Number used: (� s(O\ ogokg R 2.Locations: 3.Number removed: Q.Welded Piping-If welded piping was use J in the system, F.Pipe and Fittings complete the following: 1.Type of Pipe: Y.- 5 0 1. As the sprinkler contractor,were welding roceddres in 2.Type of Fittings: r L gompliance with the requirements of at le t AWS B2 Y G.Alarm Valve or Flow Indicator ,ASME Section IX or other required star(d ds Yes ❑No Tvne Make I Model I Max,Time to Operate Through Iris t 2.Was welding performed by welders qua]if ed in 0 SvC- compliance with the requirements of at I't ist AWS 132/I; ASME Section IX or other required stand irds dYes ❑No H.Dry-Pipe Valve 3.Do you certify that welding was carried o in compliance Make,Model and Serial Number: with a documented quality control proceed re to insure that I.Quick Opening Device(Q:O.D.) all discs are retrieved,openings in pipe i r smooth,slag and Make,Model and Serial Number: other welding residue are removed,the in ernal diameters of J.Dry-Pipe System Operating Test Without Q.O.D. piping are not penetrated,completed welds are free from cracks, 1.Time to trip through test connection*: incomplete fusion,surface porosity grea(e than 1/16 inch in 2.Water pressure psi. Air pressure psi. diameter,undercut deeper than the lesser of 25%of the wall 3.Trip point air pressure psi. thickness or 1/32 inch,and the completed ircumfere0161 4.Time water reached test outlet*: butt weld reinforcement does not exceed /32 inch?d Yes ❑No 5.Alarm operated properly DYes q No R.Cutouts(Disks) K.Dry-Pipe System Operating Test With Q.O.D. Do you certify that you have a control featuTc to 1.Time to trip through test connection*: ensgre that all cutouts(disks)are retrieved? d YY s ❑No 2.Water pressure psi. Air pressure psi. S.Hydraulic Data Nameplate Provided Q Yes 0 No 3.Trip point air pressure psi. T.Date left in service(with all control valves open): 4.Time water reached test outlet*: U.Signatures r 5. Alarm operated properly DYes 0 No 1. Name of sprinkler contractor: L.Deluge and Preaction Valves 2.Tests witnessed by: 1.Make&Model: For property owner(Signed): 2.Operation: ❑Pneumatic O'Electric ❑Hydraulic Title: k. 1'7- Date: �l5 3.Piping and detecting media supervised DYes 0;No 1i or sprinkler contractor(Signed). Title: �T" Date: 4.Does valve operate from manual trip and/or V.Comments(This section is for additional!e planation and notes. All remote control stations ❑Yes Ell,No "No""answers must be explained here.) 5. Is there an accessible facility in each circuit for testing ❑Yes Q No 6. Does each circuit operate supervision loss alarm ❑Yes ❑INo 7 7.Does each circuit operate valve release DYes ❑!No 8.Maximum time to operate release: �u M..Pressure Reducing Valve �. 1.Location and Floor: ` 2.Make and Model: 3.Setting: Static Pressure: Inlet _psi, Outlet i t t 4. Residual Pressure(Flowing):Inlet psi, Outlet p 5.Flow Rate: gpm N.Test Description )�-Flydrostatic: Hydrostatic tests shall be made at not less than 200 psi two hours or 50 psi above static pressure in excess of 150 psi for two hours. Differential dry-pipe valve clappers shall be left open duri�g t t to prevent damage.All aboveground piping leakage shall be stopped. Pneumatic: Establish 40 psi airpressure and measure drop. Test pressure tanks at normal water level and air pressure and measureiair pressure drop. In both cases,the pressure drop shall not exceed It z p i in 24 hrs. *Measured from the time the inspector's test connection is opened o Check here if comments continue on the reverse side of this form ©2007 National Fire Sprinkler Association,40 Jon Barrett Road Matte on,NY 12563(845)'878-4200 Form 13-A,Page 1 of I Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Friday, June 29, 2018 5:07 PM To: Jacqueline Boges Subject: [Request received] 36763 Eiland Blvd by#19892 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: htti)s://zephyrhillsfl.zendesk.com/hc/requests/223585 ....................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Jun 29, 2:07 PM MST service 36763 Eiland Blvd by#19892 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 Jacqueline Boges From: Nichole Spence(City of Zephyrhills Support )<support@zephyrhillsfl.zendesk.com> Sent: Saturday, July 14, 2018 12:11 PM To: Jacqueline Boges Subject: [FATHOM] Re: 36763 Eiland Blvd by#19892 ##- Please type your reply above this line -## Your request (#223585) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/223585 ....................................................................................................-................................................................................................................................................................................................................................. .......................... ......... Nichole Spence (City of Zephyrhills Support ) Jul 14, 9:1 1 AM MST Duplicate ticket! Ticket# 223583 submitted with same BP info. I 36763 Eland Blvd by#19892 Add t incident A-223583 Ai 1 ! ' 36763 Eiland Blvd [gyp#19892 Jun 20 02:04 pm �' CJ Funnell <cjfunnell@ci.Zeph�,rhilis.fl.us> Best Regards, Nichole I FATHOM Support ................................................................... ............. ........................................................................................................................................................ ................................................................................................................ i Jacqueline Boges , - Jun 29, 2:07 PM MST service 36763 Eiland Blvd by#19892 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 mil. 1 i City of Zephyrhills Uniform Notice of a Low-Volta e Alarm�^S/yste Project Owner's/CustomerName /� l C(a JG #2101� Address 3 0 7 3 'CA04 j6I V9 City a 5 St Zip Z ---- — Phone3,5 '- _573-&4q -mail Contractors i_CZ7,,,,,'lle& "4AI C _6'nS Lic.#GS f2aa1338 AddressIA (p (Nr1/e2 g V D g City l^��� St TL zip s 36l 9 Phone —Date ProjectComc bete Scope of Work;C L4 V L�4G dJ w1 A r!4g f e C''4(3Lr7Q - CRT)I Signatur . Tt or tenant or contractor or authorized representative Notice is hevoltage alarm system project has been completed at the address specified abf the foregoing information is true and accurate. 10/1/13 section 553.793 FS 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 352 573 — 8446 Owners Name FLORIDA MEDICAL CLINIC Owner Phone Number 813-780-8440 Owners Address 38135 MARKETSQUARE Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 36763 EILAND BLVD LOT# SUBDIVISION CITY OF ZEPHYRHI PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH e INSTALL e REPAIR PROPOSED USE = SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK INSTALL LOW VOLAGE DATA CABLE AND CATY CABLE BUILDING SIZE SQ FOOTAGE= HEIGHT rrrrrr 1'•rIT'� =BUILDING $ VALUATION OF TOTAL CONSTRUCTION ©ELECTRICAL $ 60000 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO ��...-. ..-.—.—..- . .-. 1—. . . . .�F:—. . . ..-t— . . . . . . Cam. BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address I License# OTHER I COMPANY I KCI COMMUNICATIONS INFRASTRUCTURE SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address 616 WARE BLVD,TAMPA,FLORIDA 33619 License# I ES12001338 IIIIIIIIIIIIIIIIIIIIIIIIIIillllllllllllllllilllllllllllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionstlarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . .. ..�4.��' ....... . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) •• Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Yf1J r (/�(—/ Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) c�� Driveways-Not over Counter If on public roadways..needs ROW C VNO G'C t CITY OF ZEPHYRHILLS 5335-8th Street 20709 (813)780-0020 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit 9:20709 Issued: 1/22/2019 Address: 36763 EILAND BLVD Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: Total Fees: Subdivision: CITY OF ZEPHYRHILLS Amount Paid: Date Paid: Parcel Number: 04-26-21-0000-00100-0060 CONTRACTOR INFORMATION OWNER INFORMATION Name: ELKINS ENTERPRISE Name: FLORIDA MEDICAL CLINIC Addr: 14529 N FLORIDA AVE Address: 38135 MARKET SQ TAMPA FL 33612 ZEPHYRHILLS FL 33542 Phone: (813)264-1907 Lic: Phone: 813-780-8440 Work Desc: LOW VOLTAGE APPLICATION FEES INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL REINSPECTION FEES:(c)With respect to Reinspection fees:will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. 6 CONTRACTOR PER M M-85FFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Op City Of Zephyrhills Uniform Notice ofa Lout-Voltage Alarm System Projectyn Owner's/CustomerNam !'�e O�rrlA*44 W t-/`t�Wk, Address 3 �ffrf �!�to City �P�lt if/`� .g St)Zip Phone E-mail Contractor' t Lic.#i&Q,0,6*0 9 Address /ys2 City d� St Zip j Phanef/.3fn/�y�� DateProjectComplete j Scope of WorU /,7 141 A s�t!/1'1 {� Signatur ll' s f Owner or tenant or contractor or authorized representative Notice is hereby given that a low-voltage alarm system project has been completed at the address specified above.I certify that all of the foregoing information is true and accurate. r 10/1/13 section 553.793 FS 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received / Phone Contact for Permitting Owner's Nam ON•�Je;t- �'4. AI r Owner Phone Number Owner's Address I Owner Phone Number Owner Phone Number JOB ADDRESS fo G � And �/ LOT# SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED R NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK �r5 BUILDING SIZE SQ FOOTAGE= HEIGHT F_ =BUILDING �- $ �Srdo� VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = DUKE ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATUR� REGISTERED Y/ N F CURREN Y/N Address Lice ns G Or�D 0 ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities& 1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" 6._ which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but'are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. `I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19921 BUILDING PERMIT PERMIT INFORMATION = LOCATION-INFORMATION Permit Number: 19921 Address: 36763 EILAND BLVD Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: SITE WORK Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 04-26-21-0000-00100-0060 Improv. Cost: 501,000.00 OWNER INFORMATION Date Issued: 7/05/2018 Name: FLORIDA MEDICAL CLINIC Total Fees: 2,575.00 Address: 38135 MARKET SQ Amount Paid: 2,575.00 ZEPHYRHILLS FL 33542 Date Paid: 7/05/2018 Phone: 813-780-8440 Work Desc: SITE WORK CONTRACTORS APPLICATION FEES CIVIL SITE CONSTRUCTORS INC BUILDING FEE 2,545.00 CONTRACTOR CERTIFICATE 30.00 Ins ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER misc.- ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ti CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: Jacqueline Boges Sent: Monday, July 9, 2018 10:16 AM To: 'scott@civilsiteconstructors.com' Cc: 'thomas@wallace-associates.com' Subject: RE: Eiland Address FMC MOB Attachments: Permit form Page 1.xlsx; Permit form Page 2.doc Hello Scott, Thank you for stopping by on Friday to take care of you contractor license and picking up the permit card. I did not leave instructions for Debra to get you to fill out application .So I have attached an application for you I need it fill out and you may email back to me so I can place with the permit card. Thank you If you have any question let me know .1 also left you a message on your machine. daekie Boges SIJ-790-0020 ext 39IJ "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have."Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. From:Jacqueline Boges Sent: Monday,July 2, 2018 7:39 AM To: 'thomas@wallace-associates.com'<thomas@wallace-associates.com>; Bill Burgess<bburgess@ci.zephyrhilis.fl.us> Cc: 'Rene Gosselin'<rene@wallace-associates.com>; Kalvin Switzer<kswitzer@ci.zephyrhills.fl.us>; 'Charlie Potter' <Charlie.Potter@avidgroup.com>; 'James Harlow' <james.harlow@avidgroup.com>; 'Charlene Franklin' <chaHene@aI lied roofingtampa.com> Subject: RE: Eiland Address FMC MOB Thank you . What is the name of the company so that I can be on the look out ?The cost of the permit will be $2,545.00. From:thomas@wallace-associates.com <thomas@wallace-associates.com> Sent: Monday,July 2, 2018 7:03 AM To:Jacqueline Boges<jboges@ci.zephvrhills.fl.us>; Bill Burgess<bburgess@ci.zephvrhills.fl.us> Cc: 'Rene Gosselin'<rene@wallace-associates.com>; Kalvin Switzer<kswitzer@ci.zephyrhills.fl.us>; 'Charlie Potter' 1 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20 7 FIRE ALARM SYSTEM PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20767 Address: 36763 EILAND BLVD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 04-26-21-0000-00100-0060 Improv. Cost: 30,000.00 OWNER INFORMATION Date Issued: 2/15/2019 Name: FLORIDA MEDICAL CLINIC Total Fees: 200.00 Address: 38135 MARKET SID Amount Paid: 200.00 ZEPHYRHILLS FL 33542 Date Paid: 2/15/2019 Phone: 813-780-8440 Work Desc: INSTALLATION FIRE ALARM CONTRACTORS APPLICATION FEES CRITICAL SYSTEMS SOLUTIONS ING FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 100.00 FIRE INSPECTION FEES 50.00 Ins ections Required FIRE ACCEPTANCE Final FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME ENT " rw- tl� - CO RACTOR SIGNATURE PERMIT OFFIC PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received Phone Contact for Permit Owner's Name I^ ` � / Owner's Phone Number Owner's Address Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address I �.kJ Lot# Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Bum Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale 0 Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL t y Pelm7i F 7n ter Sprinkler 0 ❑ ❑ ❑ = Recreational Burn Fire Alarm ❑ ❑ ❑ = Sparklers Hood Cleaning ❑ ❑ ❑ Sprinkler System Installations Hood Suppression ❑ ❑ ❑ El Standpipes(Sprinkler Sys) V ' Fire Alarm Installation Torch Roofing/Tar Kettle lJ l ar Fire Pumps Waste Tire Storage ANNUAL " Flammable Application-ANNUAL 13 6 / Valuation of Project Fuel Tanks 0 Other: Contractor Company �' I'ca, S J v s hl Signature Registered Y/N Fee Current Y/N Address License# Z — 0 0 0 G 2 ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y/N Address License# OTHER Company Signature Registered Y/N Fee Current Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED The undersignedunderstamds that this permit may be subjectto"deed"restrictions" which may be more reathuU Cou nty The undaroignedassumes rmnponoibi|i �r compliance xv�hany applicable deed restrictions. ' UNLICENSED CONTRACTORS AND CONTRACTK��� �XES RESPONSIBILITIES: If the owner has hired aomn�o�o or oontnacU»m; buundmrtako work, they may be required to be licensed in accordance with state and local regulations. If the onndnaohor in not licensed as required by |ovx both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they,are advised 0o contact the Pasco County Building Inspection Division—Licensing Section ot727c847- 8008. Fudhermona, if the owner has hired a contractor or oontmoobzro, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. 'Kyou' as the owner sign as the oontnaotor, that may baan indication that he is not properly licensed and is not entitled to permitting 'privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, FKorida Statutes, amamnewded): |f valuation of work|m$2.6O0.00or more, | certify that |' the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant iesomeone other than the "owner", | certify that | have obtained a copy ofthe above described document and promise in good faith to deliver ithm the"mwner"prior&ocommencement. - CONTRACTOR'S/OWNER'S AFFIDAVIT: i certify that all the information in this application is accurate and that eU'xmorhwill be done in compliance with all applicable laws regulating monstruotiPn, zoning and land development. Application is hereby made to obtain a permit to do work anf installation as indicated. YcsrtKv that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws nagu|obnQ oonotn|xt|on. County and City codes, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take bn be-in compliance. If| am the AGENT FOR THE OWNER. | pnmm|mo in good faith to inform the owner of the permitting conditions set forth in this affidavit priorbmcommencing construction. | understand that a separate permit may be required for electrical vxork, p|umbing, gigng, xveUe, poo|o, air conditioning, Qan, or other installations not specifically included in the application. A permit issued shall be-construed toboa license bo proceed with the work and not an authority ho violate, cancel, alter, mr set aside any provisions of the technical oodeo, nor ahoU ioauonom of a permit prevent the Building Official from thereafter requiring a correction of errors iriplans, construction or violations of any codes. Every permit issued shall become invalid unless the xvmrh authorized by such pmnnD is commenced within six months of permit iaauanoe, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work iocommenced. An extension maybe requested,'in writing, from the Building Official for o period not to exceed nineh/ (GO) days and Will demonstrate justifiable cause for the extension. If work ceases for ninety/9O\consecutive days, the job ioconaideredab�ndmn�d� ' . WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this b by Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. asidentification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowners Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COM NCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTM TO OBTAIN FI CING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N6609-0-)F-COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACT / G Subscribed and swornto(or affirmed)before me this Subscribed an b r r affirmed before me this ` 11 t v t Y Y "�Av �I Z— Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. T -4 06.V�CIL e 6 W(OL Name of Notary typed,printed or stamped Name of Nota typed, rinted or s a p 4O NNotary Public State of Florida Diane K Naszkiewlcz MY Commission GG 262657 \1 Or W Expires 0912t W22 ZEPHYRHIL.ILS FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.:Plan No.: Contractor: Business Name: �JDI c 4-Z Billing Address: Business Address Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: s✓) 1 K& PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Education,healthcare,De tention&Correctional Public Assembly,Business, schools, Storage,Mercantile and Churches Site Plan N/C Industrial. no charge Sprinkler $50 Multi-Family/Commercial .03 sf up to 800 sq ft $ 24.00 Standpipes $50 (Minimum Charge$24.00 801 -1,500 sq ft $ 34.52 Fire Pump $50 Plan Revisions DBL 1,501 -2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 )C Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-25 Heads $50 5,501-7,500 sq ft $ 187.52 Natural Gas $50 26 plus Heads $100 7,501-10,000 sq ft $ 262.52 Fuel Tanks- pertank $50 STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation' $25 Per Pump $100 30,001-40,000 sq ft $ 1,050.02 Controlled Bum(15da. $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25 Devices $50 60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual 80,001-($2,100.02)per 26 plus Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed until Flammable Application $50 Annual Wet $50 violations corrected) Waste Tire Storage $50 Annual Dry $50 SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 Hydro Undergrounds $45 Generator>30 KW $100 Other $50 Hydrostatic Test $65 per system. Bio-Hazard Waste $100 Annual KITCHEN EXHAUST Acceptance Test $45 per system . Fumigation Tenting $50 ® Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual LP Installation per tank $50 FIRE ALARM SYSTEM Fuel Tank Installation $50 MSystem Acceptance $50 (Per Tank) $50 nRecall Acceptance $50 Natural Gas Installation $50 OTHER (Per System) Fire Wall/Smoke Wall $15 per wall Spray Booth $50 LP Gas $25 per tank Natural Gas $25 per system Tent 10'x10'or greater $15 per tent Fire Pump $45 Fire Suppression $30 System Acceptance Exhaust Hood/Duct $30 Re-inspection - DBL (other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS TOTAL /00 INSPECTION TOTAL PERMIT TOTAL S- 6 GRAND TOTAL 1 $r o Comments: Date: 4ZI 4t'l Inspector: — see back nlh FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm N/C 3rd Alarm -N/C 4th Alarm .$100 5th Alarm $150 6th Alarm -$200 NONCOMPLIANCE $150 Cont.Annual lnspectlen Fees 3-11 Units price per'unit. $ 5.36 12-25 Units price per unit $ 4.82 26 50 Units price per unit $ 449 51-100 Units price per unit $ 3.75 100 or more Units price per unit $ 2.68 Fire Safety re-inspection types First Re-inspectior N/C Second re-inspect $75 Third re-inspectior $' 125.00 Inspection-scheduled but cancelled-24 hrs $ 50.00 4. TOTAL nlh o . ri`diitin City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: c, Date Received: 6 _ t V-- W Site: Permit Type: Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Ge Brown—Fire Safety Officer Da / Contractor and/or Homeowner (Required when comments are present) CMI-Cp' FIRE ALARM—SPRINKLER—ACCESS CONTROL—SECURITY-CCTV—MONITORING Official Distributor: *NOTIF1ER® AESIlntelliNet August 23, 2018 To whom it may concern: At a meeting of the Board of Directors of Critical Systems Solution, LLC held on August 22, 2018, it was duly and jointly resolved that the following individuals, whose names are hereby attested, are empowered on behalf of Critical System Solutions, LLC and State of Florida Electrical Contractors License holder EF20000427 to perform on behalf of David Kirk. For t4/Oweicensee: avier it isl �� Date Designated individuals listed below: Bill Rhodes Drivers License R320-926-56-024-0 Kevin Lang Drivers License L520-513-74-414-0 Mike Cyra Drivers License C600-550-57-171-0 Yoel Alfonso Drivers License A415-960-86-226-0 Plot Public Stft of fllide o . DianaM K lVnsz*ikiewicz Stare of: Florida Ex Res00/Comsion 22 zsses7 �� ExpNes a0@srzo22 County of: Pinellas 04 Sworn to and subscribed before me this: 8 S*` Day of 0 A(V LA-ar o�U lfi �c Notary Public State of Florida at Larg _ 2830 Scherer Drive,Suite 300♦St.Petersburg,FL♦33716 Phone:727-209-5122 ♦ Fax:727-209-5126 EF#20000427 ♦ FPC18-000060 www.criticalsystemsolutions.com r_. CRITICAL SYSTEM SOLUTIONS,.LLC FIRE+SECURITY*NURSE CALL+ACCESS CONTROL*CCTV*MONITORING www.criticalsystemsolutions.com FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL PROJECT: Florida Medical Clinic Eiland Boulevard & Simons Road Zephyrhills, FL ELECTRICAL CONTRACTOR: Suncoast Electric 7199 30t"Avenue North St. Petersburg, FL 33610 FIRE ALARM CONTRACTOR: Critical System Solutions, LLC 2830 Scherer Drive, Suite 300 St. Petersburg, FL 33716 727-209-5122 Office 727-209-5126 Fax 813-618-2170 Cell CONTACT Mike Cyra 2830 Scherer Drive Ste.300•St Petersburg, FL•33716 St. Pete: 727-209-5122 Tampa: 813-341-5102 Fax: 727-209-5126 Toll Free: 866-434-4CSS EF#20000427 FIRE ALARM SYSTEM EQUIPMENT SUBMITTAL. Florida Medical Clinic-Zephyrhills May 18, 2018 - - - - ---- ------------------ QTY PART# DESCRIPTION ------ --- --- - - - - ----- - - - -------- - 1 NFW2.-100- ---- -Notifier- - Addressable----- - Fire Alarm-- -- Cont-rol Panel consisting of:- 1 -XRM-24B Power Expansion Transformer 2-PS-1212012v 12ah Sealed Lead Acid Backup Batteries 2 N-ANN-80 Notifier Remote LCD Annunciator. Mounts to a 2.1/8" deep 4sq box furnished and installed by electrical contractor 1 FCPS-24S8 Notifier Remote Notification Power Supply consisting of: 2-PS-127012v 7ah Sealed Lead Acid Backup Batteries 17 NOT-BG12LX Notifier Addressable Pull Station. Mounts to a single gang electrical --- ---- -- - --------- - --- --- box furnished and installed by electrical contractor 64 NP-100 - Notifier Addressable Smoke Detector. Furnished with one(1)B210LP� Detector Base. Mounts to an octagonal electrical box furnished and installed by electrical contractor 4 NH-100 Notifier Addressable Heat Detector. Furnished with one(1) B210LP Detector Base. Mounts to an octagonal electrical box furnished and -installed b electrical contractor ------- - ----------- ----- - ----- ---- -- - ---------- -- - - ---------- 4 DNR Notifier Addressable Duct Smoke Detector. Furnished with the following: 1 -NP-100R-Addressable Smoke Detector Head 1 -DST5-Duct Sample Tube, 5' Length 1 -RTS151 -Duct Remote Test Station 6 NMM-100 Notifier Addressable Monitor Module. Mounts to a 2-1/8" deep electrical box furnished and installed by electrical contractor 14 NC-100R Notifier Addressable Relay Module. Mounts to a 2.1/8" deep electrical box furnished and installed by electrical contractor -I ------ --- --- ------- ----- -- ------------------- --- - -- - -- 45 P2WL System Sensor Horn Strobe,Wall Mounted,White. Mounts to-a--2-.1—/8" Deep 4 square electrical box furnished and installed by electrical contractor 20 SWL System Sensor Strobe,Wall Mounted,White. Mounts to a 2.1/8" Deep 4 l square electrical box furnished and installed by electrical contractor 2 P2RK System Sensor Horn Strobe,Weatherproof,Wall Mounted, Red. Mounts to a factory supplied surface,weatherproof back box installed b electrical contractor -- - - - -- ------- --- ectri-- ----------- -- --- --- -- - - ---- DK-120HW Ditek 120VAC Surge Suppressor 2 DK- Ditek Phone Line Surge Suppressor MRJ31 SCPWP 2830 Scherer Drive Ste.300•St. Petersburg, FL.33716 St. Pete: 727-209-5122 Tampa: 813-341-5102 Fax: 727-209-5126 Toll Free: 866-434-4CSS EF#20000427 DN-60602:A1 FireWarden-100-2(E) Rev 3 (1 N OTI F I E R° Intelligent Addressable FACP by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3(NFW2-100)with Version 5.0 firmware is a combination FACP(Fire Alarm Control Panel) and DACT(Digital Alarm Communicatorlfransmitter) all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol W�`1Otl technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The's quick-remove chassis protects the electronics during con- yoriRun struction.The backbox can be installed allowing field wiring to be pulled.When construction is completed, the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS, and increased power for the reset- table and remote sync outputs. s Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public . Remote site or local USB port upload/download, using PS- switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four (4) Style Y (Class B) NAC circuits, which can be con- load utility. In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windows®XP or greater, a com- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software . Selectable strobe synchronization for System Sensor,Whee- kit--may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, . Remote Acknowledge, Silence, Reset and Drill via address- walktest data, current status and system voltages. The panel able monitor modules or FDU-80, N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged . ANN-BUS for connection to following optional modules(cannot directly into the printed circuit board.This permits easy typing of address labels and other programming information. be used if ACS annunciators are used): Version 5.0 firmware supports the following: Primary and Sec- ondary ANN-bus devices,NP-Al00,USB port,NAC circuit diag- —N-ANN-1/0 LED Driver nostics, a new report has been added to the walk-test that lists —N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone —N-ANN-RLY Relay Module type code for NFV-25/50ZST,Photo Supervisory and auto-reset- —N-ANN-LED Annunciator Module table Drill(non-latching). —N-ANN-BLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT2 —ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone —ACS Annunciators:Up to 32 Legacy ACM Series annuncia- line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE. Unless otherwise specified, the term 'FireWarden-100-2" —Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the FireWarden-100-2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NF1412-100E as well. cuit board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lation is excessive. • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm'Silence printout. Drill • Point trouble identification. System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point . Enter (NFPA 72 compliant). NOTE.Only detectors may participate in PAS. Product Line Information SLC LOOP: +NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E:Same as NFW2-100,except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NA CS): tion. • Four onboard NACs with additional NAC capability using out- 4XTM Reverse Polarity Transmitter Module: Provides super- put control modules (NC-100). The four Class B NACs can aided output for local energy municipal box transmitter, alarm, and trouble. be converted to four Class A NACs with optional ZNAC-92 converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y(Class B) NAC circuits to four(4) Style Z(Class A) cir- cuits. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. PS Tools: Programming software for WindowsC�-based PC • Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. • 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. NOTE.Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi-flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE. CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram(learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHGA20: Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than • Continuous fire protection during online programming at the 18AH. front panel. BAT Series:Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not+XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows(D-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable;required for printer or for local upload/download program- able on www.magni-fire.com). Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT 2/2UD, IPDACT Internet Monitoring Module: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). Connects to primary and secondary DACT telephone output User Interface ports for internet communications over customer provided ether- LED INDICATORS net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) IP.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT:Mounting kit for IPDACT2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-60(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or..black fication appliances. enclosure(see DN-60242). NC-10OR: Addressable relay module containing two isolated N-ANN-RLED:Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SM13500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: Serial/Parallel Printer Gateway module provides modules in a BB-XP cabinet(optional).Mount up to six modules a connedtion for a serial or parallel printer.(See DN-7103.) on a CHS-6 chassis in a 1313-25. N-ANN-UO: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R:Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional).Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a 1313-25. of providing up to 99 software zones of annunciation.Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N1004SO(DN-6994),NP-100 series custom graphic annunciators. (DN-6995),NI-100(DN-6996), NH-100 series(DN-6997),ND-100 series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point-annunciator: 80-char- NDM-10017VZM-100 (DN-6999), NC-100/NC-1001? (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the FireWarden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(DN- 0524),LDM Series(DN-0551),FDU-80(DN-6820). While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mmz) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector. manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-10OT:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100:Fast-response,low-profile heat detector. NH-10OR: Fast-response, low-profile heat detector with rate-of- rise option. NH-10OH: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-10OR separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-10OR separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-10OP: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification DN-60602:A1-12/07/2010—Page 3 of 6 I FireWarden-100-2 Rev 3 f-------f--------------------------- Fire Alarm ControU ANN-BUS Communicator or ANN-BUS DEVICES i EIA-485 N-ANN-80,N-ANN-LED, ? in ACS mode N-ANN-S/PG,N-ANN-1/0 (two wires) : ■■I■■ SMOKE DETECTORS MEMO NP-100,NP-100T, 24 VDC NI-100,NP-A100 Optional f REVERSE� POLARITY/ HEAT DETECTORS� CITY BOX NH-100,NH-100R,NH-100H OUTPUT ANNUNCIATORS ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS DUCT DETECTORS NOTE:System can use (optional,order ACM-8R) ND-100,ND-100R,DNR either ANN-BUS devices OR ACS-mode annunciators. They cannot be used o simultaneously. 01 NACs(Notification Appliance Circuits) ' BELLS,SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-10OR INTERFACE (PIM-24)built into the motherboard 0 11111 ADDR• ABLE MULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They (� cannot be used simultaneously. EIA-485 INTERFACE 24 VDC (four wires) MINI-MONITOR _ NMM-100P OIOIDI"o FDU-80 Up to 6,000 ft.(1825.8 m) between each FDU-80 in • the EIA-485 loop,and between PULL STATION each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.) deep.Trim Ring(TR-CE- B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Intelligent Signalling Line Circuits.........................................1 • Addressable device capacity..........................................`.198 Shipping Specifications • Programmable software zones...........................................99 • ACS Annunciators..............................................................32 Weight: lbs. ( kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • ANN-bus devices................................................................16 Electrical Specifications Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 49°C/32—120°F and at a relative humidity 93%t 2%RH(non- amps. FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C t 2°C (90°F t 3°F). However, the useful Wire size:minimum 14 AWG(2.00 mmz)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH-18 AH batteries.Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet. Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120, and a separate battery cabinet such as the BB-26 or temperature of 15—270C/60—80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y (Class B)for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B) or with an optional ZNAC-92 module converts to four —LOCAL (Automatic, Manual, Waterflow and Sprinkler Style Z(Class A) NACs. Maximum signaling current per circuit: Supervisory). 2.5 amps.End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 UL listed)for Style Y(Class B)NAC. Refer to panel documenta- —AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notirier Device Compatibility Document for listed com- 4XTM). patible devices. —REMOTE STATION (Automatic, Manual, Waterflow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps @ 30 VDC (resistive),0.5 amps @ 30 alarm,trouble and supervisory relays may be connected to VAC(resistive).Form-C relays. UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTM is required.) Special Application Non-resettable Power (24 VDC Nome- —PROPRIETARY (Automatic, Manual, Waterflow and Sprin- nal):Jumper selectable(JP4)for conversion to resettable power kler Supervisory). output. Up to 1.0 amp total DC current available from each out- put.Power-limited. —CENTRAL STATION (Automatic, Manual, Waterflow and Sprinkler Supervisory). Special Application )for Coble Power on VDC nominal): —OT,PSDN(Other Technologies, Packet-switched Data Net- Jumper selectable(JP6)for conversion to non-resettable power. work) Up to 1.0 amp total DC current available. Refer to the Notirier Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA.End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel.In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed: S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line . FM approved directly from your local phone company. Do not use shared phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER@ is a registered trademark of Honeywell International Inc. Wheelock@ is a registered trademark of and ExcederTm is a trademark of Cooper Notification. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9oo1 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate.all requirements. 11111INEERINC 9MMINIC71MNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118, www.notifier.com Page 6 of 6—DN-60602:A1•1 2/0 712 0 1 0 ,. 0 I 1 12 Volt 12.0 AH Rechargeablei e a 0 Absorbent Glass Mat (AGM) technology for superior performance -----_ Valve regulated, spill proof construction allows safe operation in any position Ppu/EB �rON/� MODEL pS-12120'F2 I • Power/volume ratio yielding unrivaled energy density 12Volt 12.DAMP-Hr. • Rugged impact resistant ABS case and cover (UL94-HB) • Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B. certified • U.L. recognized under file number MH 2O845 Terminals: (mm) Performance Specifications • F2-Quick disconnect I-3.4--1 Nominal Voltage.......................................................12 volts (6 cells) tabs,0.250"x 0'032" I6.35 Nominal Capacity -Mate with AMP.INC 20-hr. (600mA to 10.50 volts) .......................................... 12.0 AH FASTON"250"series F--7.99] ®=0.8 10-hr. (1.1 A to 10.50 volts) ............................................. 11.0 AH • NB-Tin plated brass .12 H T 5-hr. (2.1 A to 10.20 volts) ............................................. 10.5 AH "'I posts with nut&bolt 1q 1;Itt 00 1-hr. (7.25A to 9. volts) fasteners 7.25 AH 15-min. (21.5A to 9.00 volts) ...............................................5.38 AH Physical Dimensions: in (mm) Approximate Weight ......................................... 7.92 lbs. (3.59 kg) Energy Density(20-hr. rate) ............. 1.69 W-h/in3 (103.41 W-h/1) Specific Energy(20-hr. rate) ............ 18.18 W-h/lb (40.08 W-h/kg) w Internal Resistance (approx.) ..................................... 20 milliohms e Max Discharge Current(7 Min.) ............................... 36.0 amperes E Max Short-Duration Discharge Current(10 Sec.) .. 120.0 amperes Shelf Life (%of nominal capacity at 68OF (20°C) TFla— f`1 1 Month ................................................................................. 97% T 3 Months................................................................................ 91% wot�r mifat. � HT H MODEL PS-1]110F] 6 Months ............. 83% Operating Temperature Range L Charge .................................................4°F (-200C) to 1221F (50°C) (1 F2: tP8 9 8 «. _ Discharge .............................................40°F (-40°C) to 140OF (60°C) L:5.94 51)N/ 36( )'Hi 3R6 6(9 3)`HT: 3.8 6 (9 8) 9 are+/,0.04 in. m a a � Case..................................................................................ABS Plastic t8 (,98)H; 6 (93')HT:4.09(104') Power-Sonic Chargers.............................PSC-122000A, 122000A-C Tolerances 0.08 in.(+/-2mm)for height dimensions.All data subject to change without notice. To ensure safe and efficient operation All data subject to change / I 12 Volt1 AH / `I Shelf Life & Storage Discharge Characteristics 100 ChaM14.0 necessary snot AmbientTem Temperature 20°C 68°F necessary unless' p ( ) p 1 00%of capacity 13.0 a80 is required. j -- Charging before 12.0 c 5°C use is necessary m - p (41°F) to help recover Ol fug capacity. -- .pp. 60 ; 11 A Chargernayfalr,to restore full 0.60 40°C 30°C 20°C capacity.Do not c 10.0 1.2 - t� 40 (104°F) (86°F) (68°F) let batteries reach £ P2.4 to this state. 6.0 C ~ V 0 9.0 Final 12 0 2 4 6 8 10 12 14 16 18 20 Voltage Standing Period(Months) 6•0 24 1.2 2.4 6 12 24 36 481 2 4 6 810 20 40 Discharge Time vs. Discharge Current 1 min -I• h 1 Discharge Time 20 15 10 Life Characteristics in Stand-By Use tv 5 Final 0 100 Ambient Temperature 20. (68°F) E Voltage v 2 10.5V \� 80. 10.2V 60 H 1 c ao Float Charging Voltage 9XV \� 2.25-2.30 V/Cell 30 aci 20 Y QI c \ 0 F 9.0V 0 1 2 3 4 10 \ \40°C(104°F) 20°C (68°F) Years 0°C (32°F) Life Characteristics in Cyclic Use 0.60 1.2 2.4 6.0 12 24 120 Discharge Current(A) 100 0 80 Cycle Applications: Limit initial current to 3.6A.Charge until battery voltage(under to charge)reaches 14-4 to 14.7 volts at 68°F(200C). Hold at 14-4 to 14.7 volts until r 60 Discharge Discharge Discharge current drops to under 120mA. Battery is fully charged under these conditions,and r_ Depth 100/ Depth 501 Depth 30% charger should be disconnected or switched to"float'voltage. p 40 d 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold battery across constant voltage source of 13.5 d 20 2.Charge Current:0.1C to 13.8 volts continuously.When held at this voltage,the battery will seek its own 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) current level and maintain itself in a fully charged condition. 0 Note:Due to the self-discharge characteristics of this type of battery,it is imperative 0 200 400 600 800 1000 1200 that they be charged within 6 months of storage,otherwise permanent loss of Number of Cycles capacity might occur as a result of sulfation. Further Information Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to our website www.power-sonic.com for a complete range of useful Please refer to the Charger Selection Guide in our specification sheets for"C-Series downloads,such as product catalogs,material safety data sheets(MSDS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Technical department for advice if you have difficulty in locating suitable models. Contact Information •• - DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650.364-5001 Fax:+1-619-661-3650 Fax:+1-619.661-3648 Fax:+1-619.661-3648 Fax:+1-650.366-3662 nofionalmles@power-sonic.com customerservice@power-sonic.com support@power-sonic.com internafionafsales@power-sonic.com CORPORATE OFFICE e 7550 Panasonic Way e San Diego,CA 92154 e USA e Tel:+1-619-661-2020 e Fax:+1.619-661-3650 0814 Inn ®2013.Power-Sonic Corporation.All rights reserved.All trademarks are the property of their respective owners. dn-7114:c•Al-65 N-ANN-80 �J N OTI F I E R° SO-Character LCD Serial Annunciator by Honeywell General The N-ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power,Alarm,Trouble, Supervisory, and Alarm Silenced condi- tions. The N-ANN-80 and the FACP communicate over a two- wire serial interface employing the ANN-BUS communication e format. Connected devices are powered, via two additional t—r� wires, by either the host FACP or a remote UL-listed, filtered •�" power supply. N-ANN-80 is black;for white order N-ANN-80-W. The N-ANN-80 displays English-language text of system point `' n"" " R' " information including device type, zone, independent point ;w 0"k6.4w6fir alarm, trouble or supervisory status, as well as any custom . alpha labels programmed into the control panel.It includes con- g '"' t'ACC ' trol switches for remote control of critical system functions. (A keyswitch prevents unauthorized operation of the control switches.) Up to eight N-ANN-80s may be connected to the ANN-BUS of - each FACP.Minimal programming is required,which saves time during system commissioning. The N-ANN-80 is compatible with NOTIFIER FACPs with an ANN-BUS,such as the NFW-50. Features • Trouble • Supervisory • Listed to UL Standard 864,9th Edition. • Alarm Silenced • Backlit 80-character LCD display(20 characters x 4 lines). • Mimics all display information from the host panel. Specifications • Control switches for System Acknowledge, Signal Silence, . Operating voltage range: 18 VDC to 28 VDC. Drill,and Reset. . Current consumption @ 24 VDC nominal(filtered and non- • Control switches can be independently enabled or disabled at the FACP. resettable):40 mA maximum. • Keyswitch enables/disables control switches and mechani- • Ambient temperature:327 to 120°F(0°C to 49°C). cally locks annunciator enclosure • Relative humidity: 93%t 2% RH (noncondensing)at 32°C • Keyswitch can be enabled or disabled at the FACP. t 2°C(90°F t 3°F).• Enclosure supervised for tamper. • 5.375" (13.65 cm.) high x 6.875"(17.46 cm.) wide x 1.375" (3.49 cm.)deep. • System status LEDs for AC Power,Alarm, Trouble, Supervi- . For use indoors in a dry location. sory,and Alarm Silence. • Local sounder can be enabled or disabled at the FACP. All connections are power-limited and supervised. • N-ANN-80 connects to the ANN-BUS terminal on the FACP Agency Listings and Approvals and requires minimal panel programming. • Displays device type identifiers, individual point alarm, trou- The listings and approvals below apply to the N-ANN-80. In ble,supervisory,zone,and custom alpha labels. some cases, certain modules may not be listed by certain • Time-and date display field. approval agencies,or listing may be in process.Consult factory • Surface mount directly to wall or to single, double, or 4° for latest listing status. square electrical box. • UL:S635 • Semi-flush mount to single, double, or 4" square electrical • FM approved box.Use ANN-SB80KIT for angled view mounting. • CSFM:7120-0028:240 • Can be remotely located up to 6,000 feet(1,800 m)from the • MEA:442-06-E Vol.2 panel. • Backlight turns off during AC loss to conserve battery power The ANN-BUS but will turn back on if an alarm condition occurs. • May be powered by 24 VDC from the host FACP or by remote POWERING THE DEVICES ON THE ANN-BUS FROM power supply(requires 24 VDC). AUXILIARY POWER SUPPLY • Up to eight N-ANN-80s can be connected on the ANN-BUS. The ANN-BUS can be powered by an auxiliary power supply when the maximum number of ANN-BUS devices exceeds the Controls and Indicators ANN-BUS power requirements. See the FACP manual for more • AC Power information. • Alarm dn-7114:c•5/22109—Page 1 of 2 ANN-BUS DEVICE ADDRESSING After calculating the total worst case current draw,the following Each ANN-BUS device requires a unique address(ID Number) table specifies the maximum distance the modules can be in order to communicate with the FACP.A maximum of 8 devices located from the FACP on a single wire run.The table ensures can be connected to the FACP ANN-BUS communication circuit. 6.0 volts of line drop maximum.In general,the wire length is lim- See the FACP manual for more information. ited by resistance, but for heavier wire gauges, capacitance is the limiting factor. WIRE REQUIREMENTS:COMMUNICATIONS CIRCUIT These cases are marked in the chart with an asterisk(').Maxi- The N-ANN-80 connects to the FACP ANN-BUS communica- mum length can never be more than 6,000 feet (1,800 m), tions circuit.To determine the type of wire and the maximum wir- regardless of gauge used. See table below. ing distance that can be used with FACP ANN-BUS accessory WIRE REQUIREMENTS:POWER CIRCUIT modules,it is necessary to calculate the total worst case current draw for all modules on a single 4-conductor bus.The total worst • 14 to 18 AWG(0.75-2.08 mm2)wire for 24 VDC power cir- case current draw is calculated by adding the individual worst cuit is acceptable. case currents for each module. • All connections are power-limited and supervised. NOTE: For total worst case current draw on a single ANN-BUS • A maximum of eight N-ANN-80 modules may be connected refer to appropriate FACP manual. to this circuit. Communication Pair Wiring Distance: FACP to Last ANN-BUS Module Total Worst Case Y2 Gauge 18 Gauge 16 Gauge 14 Gauge Current Draw(amps) 0.100 1,852 ft. 4,688 ft. *6,000 ft. -6,000 ft. 0.200 926 ft. 2,344 ft. 3,731 ft. 5,906 ft. 0.300 617 ft. 1,563 ft. 2,488 ft. 3,937 ft. 0.400 463 ft. 1,172 ft. 1,866 ft. 2,953 ft. 0.500 370 ft. 938 ft. 1,493 ft. 2,362 ft. 0.600 309 ft. 781 ft. 1,244 ft. 1,969 ft. 0.700 265 ft. 670 ft. 1,066 ft. 1,687 ft. 0.800 231 ft. 586 ft. 933 ft. 1,476 ft. 0.900 206 ft. 521 ft. 829 ft. 1,312 ft. 1.000(max.) 185 ft. 469 ft. 746 ft. 1,181 ft. WIRING CONFIGURATION ORDERING OPTIONS: The following figure illustrates the wiring between the FACP and+ N-ANN-80: Black 80 character LCD Annunciator. ANN-BUS devices. N-ANN-80-W:White,80 character LCD Annunciator. ANN-BUS and power ANN-SB80KIT B: Black surface mount backbox with angled wiring are supervised wedge. and power-limited. ANN-SB80KIT W: White surface mount backbox with angled ® B A . - wedge. TB1 4 3 2 1 ANN-BUS Device ' AB O NFW 50 TB3 1 2 3 4 5 6 7 8 FACP Wiring to ANN-BUS Device 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. IM11UUtlNO a MMURIM1111Yi All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-7114:c•5/22/09 DN-6927:A2 FOPS-24S6(C/E) & FOPS- 24SS(C/E) NOT 1 F 1 E R° �J 6• & 8-Amp 24-volt by Honeywell Remote Power Su lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S6/- 2458 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance circuit (NAC) expansion (to support ADA requirements and NAC synchroni- zation) or auxiliary power to support 24 volt system accesso- vies.The FCPS-24S6/-2458 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as - either four Class B(Style Y)or Class A(Style Z,with ZNAC-4 _ option module). Alternately, the four outputs may be config- ured as all non-resettable, all resettable or two non-resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 2456 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the _ FCPS-24S6E and FCPS-24S8E — - Features • UL-Listed NAC synchronization using System Sensor, • Includes integral battery charger capable of charging up to Wheelock,or Gentex"Commander2"appliances. 18 AH batteries.Cabinet capable of housing 7.0 AH batter- • Operates as a "sync-follower' or as a "sync-generator" ies. (default). See note on page 2. • Battery charger may be disabled via DIP switch for applica- • Contains two fully-isolated input/control circuits -triggered tions requiring larger batteries. from FACP NAC (NAC expander mode) or jumped perma- • Fixed, clamp-type terminal blocks accommodate up to 12 nently"ON"(stand-alone mode). AWG(3.1 mm2)wire. • Four Class B (Style Y) or four Class A (Style Z, with ZNAC-4 module)NACs. Specifications • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- Primary(AC)Power: put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. output in stand-alone mode(UL 1481). • Wire Size: minimum#14 AWG (2.Omm2)with 600 V insula- • Compatible with coded inputs;signals passed through. tion. • Optional power-supervision relay(EOLR-1). Control Input Circuit: • In stand-alone mode, output power circuits may be config- • Trigger Input Voltage: 9 to 32 VDC. ured as: resettable, (reset line from FACP required), • Trigger Current: 2.0 mA(16-32 V);Per Input: 1.0 mA(9 non-resettable,or a mix of two and two. -16 V). • Fully regulated and filtered power output-optimal for pow- Trouble Contact Rating: 5 A at 24 VDC. ering four-wire smoke detectors, annunciators, and other Auxiliary Power Output: Specific application power 500 mA system peripherals requiring regulated/filtered power. maximum. • Power-limiting technology meets UL power-limiting require- ments. Output Circuits: • Form-C normally-closed trouble relay. • +24 VDC filtered,regulated. • Fully supervised power supply,battery,and NACs. • 3.0 A maximum for any one circuit. • Selectable earth fault detection. • Total continuous current for all outputs(stand-alone mode): • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S6: 4.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- —FCPS-24S8: 6.0 A maximum. lizes an industry-standard reverse-polarity notification cir- • Total short-term current for all outputs(NAC expander mode): cuit(including unfiltered and unregulated NAC power). —FCPS-24S6: 6.0 A maximum. • Requires input trigger voltage of 9-32 VDC. —FCPS-24S8: 8.0 A maximum. • Self-contained in compact, locking cabinet-15"H x 14.5"W Secondary Power(Battery)Charging Circuit: x 2.75"D(cm:38.1 H x 36.83W x 6.985D). Supports lead-acid batteries only. DN-6927:A2.5/17/13—Page 1 of 2 • Float-charge voltage: 27.6 VDC. Standards and Codes • Maximum current charge: 1.5 A. The FCPS-24S6 and FCPS-24S8 comply with the following • Maximum battery capacity: 18 AH. standards: • NFPA 72 National Fire Alarm Code. Applications . UL 864:Standard for Control Units for Fire Alarm Systems Example 1: Expand notification appliance power an additional (NAC expander mode). 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four . UL 1481 Power Supplies for Fire Alarm Systems. Class B (Style Y) outputs or four Class A (Style Z) outputs (using ZNAC-4). For example,the FACP notification appliance Agency Listings and Approvals circuits will activate the FOPS when reverse-polarity activation occurs. Trouble conditions on the FOPS are sensed by the These listings and approvals apply to the modules specified in FACP through the notification appliance circuit. this document.In some cases,certain modules or applications Example 2: Use the FOPS to expand auxiliary regulated 24- may not be listed by certain approval agencies, or listing may volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A be in process.Consult factory for latest listing status. (FCPS-24S8). Both resettable and non-resettable power • UL Listed: S635,S674 options are available. Resettable outputs are created by con- . ULC Listed:S635(FCPS-24S6C&FCPS-24S8C) necting the resettable output from the FACP to one or both of • CSFM Approved: 7315-0028:225 the FOPS inputs. . -E Example 3: Use addressable control modules to activate the A: proved FM FOPS instead of activating it through the FACP notification FM Approved appliance circuits.This typically allows for mounting the FOPS at greater distances' away from the FACP while expanding Ordering Information system architecture in various applications. FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. For example, an addressable control module is used to acti- Includes main printed circuit board, transformers, enclosure vate the FCPS,and an addressable monitor module is used to (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and sense FOPS trouble conditions. Local auxiliary power output installation instructions. from the FOPS provides power to the addressable control FCPS-24S6C: Same as above,ULC-listed. module. *NOTE. Addressable FACPs are capable of locating control and FCPS-24SISR: Same as FCPS-24S6 with red enclosure. monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Includes main printed circuit board, transformers, enclosure Sync Follower/Generator Note (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installation instructions. In some installations, it is necessary to synchronize the flash timing of all strobes in the system for ADA compliance.+FCPS-24SB: 8.0 A, 120 VAC remote charger power supply. Strobes accomplish this by monitoring very short timing pulses Includes main printed circuit board, transformers, enclosure on the NAC power which are created by the FACP. When (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and installed at the end of a NAC wire run,the FCPS-24S6/-24S8 installation instructions. can track (i.e. "follow") the strobe synchronization timing FCPS-24S8C Same as above,ULC-listed. pulses on the existing NAC wire run.This maintains the overall FCPS-24S8R: Same as FCPS-24S8 with red enclosure. system flash timing of the additional strobes attaches to the FOPS. FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. When the FCPS-24S6/-24S8 is configured(via DIP switch set- Includes main printed circuit board, transformers, enclosure tings) as a"sync follower,"the FCPS's NAC outputs track the (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and strobe synchronization pulses present at the FCPS's sync installation instructions. input terminal.The pulses originate from an upstream FACP or ZNAC-4: Class A(Style Y)NAC option module. other power supply. EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire When the FCPS-24S6/-24S8 are configured (via DIP switch smoke detector power. settings) as a"sync generator," the FCPS's sync input termi- BAT 1270: Battery, 12-volt, 7.0 AH (two required, see BAT nals are not used. Rather, the FOPS is the originator of the Series data sheet DN-6933). strobe synchronization pulses on the FCPS's NAC outputs. In "sync generator'mode,the sync type(System Sensor,Whee- lock,or Gentex)is selectable via DIP switch settings. System Sensor@ and NOTIFIER@ are registered trademarks of Honeywell International Inc. ©2013 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. 'SO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. FIVIRE11Ni 8 NIIWSfA EMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6927:A2.5/17/13 DN-6995:D•Al-320 NP.100(A) Series �J N OTI F 1 E R° Addressable Photoelectric Detectors by Honeywell Addressable Devices , General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the-art - photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's -_ .-"_ FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels a FACPs.The NP-100T A adds thermal sensors that will alarm Z at a fixed temperature of 135°F (57°C). Since these detectors m are addressable, they will help emergency personnel quickly locate a fire during its early stages, potentially saving precious - rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local, visible sensor indication. Remote LED annunciator capability is available as an optional NP-100(A) in B210LP(A) Base accessory, PN RA100Z(A). The NP-100R(A) is a remote test capable detector for use with DNR(A)/DNRW duct smoke detec- tor housings. OPTIONS Features • Remote LED output connection,PN RA100Z(A). SLC LOoP Applications • Two-wire loop connection. • Unit uses base for wiring. Use photoelectric detectors in life-safety applications to provide a broad range of fire-sensing capability, especially where smol- ADDRESSING dering fires are anticipated. Ionization detectors are often better • Addressable by device. than photoelectric detectors at sensing fast,flaming fires. • Rotary, decimal addressing: 01 —99 with FireWarden-100-2 Construction and NSP-25,and 01—50 with FireWarden-50. ARCHITECTURE These detectors are constructed of off-white fire resistant plas- tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A) series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple field base to simplify installation,service and maintenance. cleaning. Mount base(all base types)on an electrical backbox which is at OPERATION least 1.5" (3.81 cm) deep. For a chart of compatible junction • Withstands air velocities up to 4,000 feet-per-minute (20 m/ boxes,see DN-60054. sec.)without triggering a false alarm. NOTE.Because of the inherent supervision provided by the SLC Factor reset at 1.5% nominal sensitivity for panel alarm loop, end-of-fine resistors are not required. Wiring "Flaps" or • y p y p branches are permitted for Style 4 (Class B) wiring. NP-100R(A) threshold level. mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed(communicat- ing with the fire panel)and latches on in alarm. Operation MECHAN/CALS Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25, or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Circuit • Mounts to:single-gang box,3.5"(8.89 cm)or 4.0"(10.16 cm) (SLC). It responds to regular polls from the system and reports octagonal box,or 4.0"(10.16 cm)square electrical box(using its type and status. a plaster ring—included). The addressable photoelectric sensor in the NP-100(A) series has a unique unipolar chamber that responds quickly and uni- OTHER SYSTEM FEATURES formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient protec- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tion. sending an alarm level signal.Because of its unipolar chamber, 94-VO plastic flammability rating. the NP-100(A) series is approximately two times more respon- • sive than most photoelectric sensors.This makes it a more sta- • Low standby current. ble detector. DN-69950•2/11/2015—Page 1 of 2 Detector Sensitivity Test INTELLIGENT BASES Each detector can have its sensitivity tested(required per NFPA NOTE:'A"suffix indicates ULC Listed model. 72, Chapter 14 on Inspection, Testing and Maintenance) when NOTE:For details about intelligent bases and their mounting,see installed/connected to a FireWarden-100-2 or FireWarden-50 DN-60054. addressable fire alarm control panel.The results of the sensitiv- g210LP A : Plug-in detector base (included); standard U.S. ity test can be printed off the FireWarden-100-2 or FireWarden-�flanged low-profile mounting base. 50 for record keeping. B21 OLPBP:Bulk pack of B210LP;package contains 10. Specification B501(A):Standard European flangeless mounting base. Voltage range: 15-32 VDC(peak). B501 BP Bulk pack of B501;package contains 10. Standby current:300 NA @ 24 VDC. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. LED current:6.5 mA @ 24 VDC(latched"ON"). Replaces 8501 BH series bases in retrofit applications. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B224RB(A): Plug-in System Sensor relay base. Screw termi- Size:2.1"(5.33 cm)high;base determines diameter. nals: up to 14 AWG (2.0 mmz). Relay type: Form-C. Rating:2.0 -B210LP(A):6.1"(15.5 cm)diameter. A @ 30 VDC resistive;0.3 A @ 110 VDC inductive; 1.0 A @ 30 -B501(A):4.1"(10.4 cm)diameter. VDC inductive. -B200SR(A):6.875"(17.46 cm)diameter. B224BI(A): Plug-in System Sensor isolator detector base. -B224RB(A):6.2"(15.748 cm)diameter. Maximum 25 devices between isolator bases(see DN-6994). Weight:3.6 oz.(102 g). ACCESSORIES Operating temperature range: for NP-100(A): 0°C to 490C F110: Retrofit flange to convert B210LP(A) to match the (320F to 1200F); for NP-100T(A):0°C to 380C(320F to 100°F). B710LP(A)profile,or to convert older high-profile bases to low- NP-100R(A):installed in a DNR(A)/DNRW-200C to 700C (-4°F profile. to 158°F). F110BP:Bulk pack of F110;package contains 15. Temperature:0°C-490C(320F-120°F). F210: Replacement flange for B210LP(A)base. Relative humidity: 10%-93%, non-condensing. RA100Z(A):Remote LED annunciator.3-32 VDC.Mounts to a U.S. single-gang electrical box. For use with 8501(A) and Listings B210LP(A)bases only. Listings and approvals below apply to the NP-100(A), NP- SMB600:Surface mounting kit 100T(A), and NP-100R(A) detectors. In some cases, certain M02-04-00:Test magnet. modules may not be listed by certain approval agencies,or list- M02-09-00:Test magnet with telescoping handle. ing may be in process.Consult factory for latest listing status. UL Listed:S1115. XR2B: Detector removal tool.Allows installation and/or removal • of detector heads from bases in high ceiling applications. • ULC Listed:S1115. XP4:Extension pole for XR2B.Comes in three 5-foot(1.524 m) • CSFM:7272-0028:0231. sections. • MEA:243-02-E Vol.2. T55-127-010: Detector removal tool without pole. • Maryland State Fire Marshal:permit 2173. BCK-20OB: Black detector covers for use with NP-100(A)only; • FM approved. box of 10. WCK-20OB:White detector covers for use with NP-100(A)only; Product Line Information box of 10. NOTE:A"suffix indicates ULC Listed model. NP-100: Addressable photoelectric detector; B21OLP base included. NP-100A: Sames as NP-100 with ULC Listing; B21OLPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA:Same as NP-100T with ULC Listing; B21 OLPA base included. NP-10OR: Remote test capable addressable photoelectric detector for use with a DNRA/DNRW duct detector housing; B210LP base included. NP-100RA: Same as NP-10OR with ULC Listing for use with a NOTIFIERO and FireWarden@ are registered trademarks of Honeywell DNRA duct detector housing;B210LPA base included. International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. I3ICIBEIKINS I MA6IFACTIRIIYC All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6995:1)•2/11/2015 DN-6997:D•Al-320 HH-100(A) Series �J N OTI F 1 E R° Intelligent Addressable Thermal Detectors for FireWarden Series by Honeywell Addressable General The NOTIFIER NH-100(A) Series thermal detectors are y addressable sensors that use a state-of-the-art thermistor sensing circuit for fast response.These sensors provide open- area protection and are intended for use with FireWarden Series (FireWarden-100-2 and FireWarden-50) and Spartan (NSP-25)addressable Fire Alarm Control Panels(FACPs). The NH-100(A) and NH-100R(A) sensors provide fixed tem- perature alarm detection at 135°F (570C). The NH-100R(A) sensor also responds to rate-of-rise conditions of greater than 15°F(8.3°C)per minute.The NH-100H(A)is a fixed high-tem- perature detector that activates at 190°F (88°C). These ther- mal detectors provide addressable property protection in a a variety of applications. NH-100(A) in 6210LP(A) Base Two LEDs on each sensor light to provide a local,visible sen- sor indication. Remote LED annunciator capability is available using an optional accessory,the RA100Z. • Low standby current. • 94-5V plastic flammability rating. Features Options: SLC loop: • Remote LED output connection to optional RA10OZ remote • Two-wire SLC loop connection. LED annunciator. • Unit uses base for wiring. • Flanged surface mounting kit. Addressing: Installation • Addressable by device. NH-100(A) Series plug-in intelligent thermal detectors use a • Rotary, decimal addressing: 01 —99 with FireWarden-100- detachable base to simplify installation, service and mainte- 2,NSP-25,01—50 with FireWarden-50. nance.Installation instructions are shipped with each detector. Architecture: Mount base(all base types)on an electrical backbox which is • Sleek,low-profile,stylish design. at least 1.5"(3.81 cm)deep.For a chart of compatible junction • State-of-the-art thermistor technology for fast response. boxes,see DN-60054. • Integral communications and built-in device-type identifica- NOTE:Because of the inherent supervision provided by the SLC tion. loop, end-of-line resistors are not required. Wiring 7--taps" or • Built-in tamper resistant feature, branches are permitted for Style 4(Class 8')wiring only. • Built-in functional test switch activated by external magnet. Applications Operation: • Factory preset at 135°F(57°C)for the NH-100(A)and NH- Use thermal detectors for protection of property. 100R(A); 190°F(88°C)for the NH-100H(A). Construction • Rate-of-rise triggers at 15°F(8.3°C)per minute for the NH- 100R(A). These detectors are constructed of off-white fire-resistant • 360°-field viewing angle of the visual alarm indicators (two plastic. The NH-100(A) Series plug-in intelligent thermal bicolor LEDs). LEDs blink red in Normal condition and turn detectors are designed to commercial standards and offer an on steady red in Alarm. attractive appearance. • Visible LEDs"blink"every time the unit is addressed. Operation Mechanicals: • Sealed against back pressure. Each NH-100(A)Series detector uses one of 99(FireWarden- 100-2, NSP-25)or 50(FireWarden-50)possible addresses on • SEMS screws for wiring of the separate base. a control panel SLC loop. It responds to regular polls from the • Designed for direct-surface or electrical-box mounting. control panel and reports its type and the status.If it receives a • Plugs into separate base for ease of installation and main- test command from the panel(or a local magnet test),it stimu- tenance. lates its electronics and reports an alarm. It blinks its LEDs • Separate base allows interchange of photoelectric, ioniza- when polled and turns the LEDs on when commanded by the tion and thermal sensors. panel.The NH-100(A)Series offers features and performance Other system features: that represent the latest in thermal detector technology. • Remote test feature from the panel. • Walk test with address display. DN-6997:D•5/17/13—Page 1 of 2 Spefications INTELLIGENT BASES Size:2.1'(5.3 cm)high;base determines diameter. NOTE:A"suffix indicates ULC Listed model. —B210LP(A):6.1'(15.5 cm)diameter. NOTE:For details about intelligent bases and their mounting,see DN-60054. —B501(A):4.1'(10.4 cm)diameter. B210LP A: Plug-in detector base Included standard U.S. —B200SR(A):6.875'(17.46 cm)diameter. ( ) g (included); flanged low-profile mounting base. —B224RB(A):6.2'(15.748 cm)diameter. B21OLPBP:Bulk pack of B210LP;package contains 10. Shipping weight:4.8 oz.(137 g). B501(A):Standard European flangeless mounting base. Installation temperature: B501BP: Bulk pack of B501; package contains 10. —NH-100(A),NH-100R(A):—40F to 100OF(-20°C to WC). B200SR(A): Intelligent sounder base capable of producing —NH-100H(A):—4°F to 150OF(-20°C to 660C). sound output with ANSI Temporal 3 or continuous tone. Humidity range: 10% to 93% relative humidity (noncon- Replaces B501 BH series bases in retrofit applications. densing). B224RB(A): Plug-in System Sensor relay base.Screw termi- Voltage range: 15 to 32 VDC peak. nals:up to 14 AWG(2.0 mmz).Relay type:Form-C.Rating:2.0 Standby current: 300 pA @ 24 VDC (one communication A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ every five seconds with LED blink enabled). 30 VDC inductive. LED current:6.5 mA @ 24 VDC. B224BI(A): Plug-in System Sensor isolator detector base. Mounting: B210LP(A) flanged base, included. See "Product Maximum 25 devices between isolator bases(see DN-6994). Line Information:Intelligent Bases"if using a different base. ACCESSORIES Fixed-temperature setpoint: 135°F (57°C) for the NH-100 F110: Retrofit flange to convert B210LP(A) to match the and NH-100R(A)(A); 190°F(88°C)for the NH-100H(A). B710LP(A) profile, or to convert older high-profile bases to Rate-of-rise detection:responds to greater than 15°F(8.3°C) low-profile. per minute. F110BP: Bulk pack of F110;package contains 15. F210: Replacement flange for B210LP(A)base. Listings and Approvals RA100Z(A): Remote LED annunciator.3—32 VDC.Mounts to Listings and approvals below apply to the NH-100(A) Series a U.S. single-gang electrical box. For use with B501(A) and detectors. In some cases, certain modules may not be listed B210LP(A)bases only. by certain approval agencies, or listing may be in process. SMB600:Surface mounting kit Consult factory for latest listing status. M02-04-00:Test magnet. • UL Listed:S747. • ULC Listed:S747. M02-09-00:Test magnet with telescoping handle. • CSFM:7270-0028:0234. XR213: Detector removal tool. Allows installation and/or • MEA:387-02-E Vol.11. removal of detector heads from bases in high ceiling applica- tions. • FM approved. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 Product Line Information m)sections. NOTE:'A"suffix indicates ULC Listed model. T55-127-010:Detector removal tool without pole. +NH-100: Intelligent thermal sensor; 1350 F (570 C); B21OLP base included. NH-10OA: Same as NH-100 but with ULC Listing; B21OLPA base included. NH-100R: Same as NH-100 with rate-of-rise feature; B210LP base included. NH-100RA:Same as NH-10OR but with ULC Listing;B21 OLPA base included. NH-10OH: Intelligent fixed high-temperature thermal detector; 190'F(88'C);B210LP base included. NH-100HA:Same as NH-100H but with ULC Listing;B21 OLPA base included. NOTIFIERO and FlreWarden0 are registered trademarks of Honeywell International Inc. 02013. All rights reserved. Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EWJI MINI A MANUFACHMNS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6997:1)•5/17/13 DN-60429:C1 DNR(A)/DNRW InnovairFlex Intelligent Non-Relay Photoelectric 0 N oT I Fill E R Duct Smoke Detector by Honeywell DevicesIntelligent General The Notifier InnovairFlex®DNR(A)intelligent non-relay photo- electric duct smoke detector and DNRW watertight non-relay photoelectric duct smoke detector feature a pivoting housin •, w� that fits both square and rectangular footprints capable of mounting to a round or rectangular duct. DNRW duct smoke detector, with its NEMA-4 rating, is listed ' ",.. as a watertight, UV resistant enclosure providing protection against falling dirt, rain, and windblown dust, splashing and T' ' K• hose directed water,allowing operators to use the detector in the most extreme environments. These units sense smoke in the most challenging conditions, �"" '°�,• _� operating in airflow speeds of 100 to 4,000 feet per minute(0.5 to 20.32 m/s), temperatures of-4°F to 158°F(-20°C to 700C), and a humidity range of 0 to 95 percent(non-condensing.) An improved cover design isolates the sensor head, which Specifications allows for ease of maintenance. A cover tamper feature indi- Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) cates a trouble signal for a removed or improperly installed Width,2.5 in(6.6 cm)Depth. sensor cover.The Notifier InnovairFlex housing provides a 3/ 4-inch conduit knockout and ample space to facilitate easy wir- Size:(Square)7.75 in(19.7 cm)Length;9 in (22.9 cm)Width; ing and mounting of a relay module. 2.5 in(6.35 cm)Depth. The Notifier InnovairFlex duct smoke detector can be custom- weight: 1.6 lb(0.73 kg). ized to meet local codes and specifications without additional Operating Temperature Range: -4°F to 158°F (-20°C to wiring.The new InnovairFlex product line is compatible with all 70°C). previous Innovair models,including remote test accessories. Storage Temperature Range: -22°F to 158°F (-30°C to Features 700c)' Operating Humidity Range: 0% to 95% relative humidity • Photoelectric,integrated low-flow technology.' (non-condensing). • Air velocity rating from 100 ft/min to 4,000 ft/min(0.5 m/s to Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s). 20.32 m/s). • Versatile mounting options: square or rectangular configu- Accessories ration. • Broad ranges for operating temperature (-46 F to 158°F - Notifier provides system flexibility with a variety of accessories, including two remote test stations and di 20°C to 70°C)and humidity(O�la t0 95°l°non-condensing), different means of visi- Patented sampling tube installs from front or back of the deble and audible system annunciation,As with our duct smoke • t detectors,all duct smoke detectors accessories are UL listed. detector with no tools required. • Cover tamper signal. DNR(W)s with a date code of 0013 or higher do not require external 24VDC for remote test applications when used with a • Increased wiring space with a newly added 3/4" conduit remote-test-capable detector. knockout. • Available space within housing to accommodate mounting ACCESSORY CURRENT LOADS AT 24 VDC of a relay module, • Easily accessible code wheels on sensor head (sold sepa- Device Standby Alarm rately). RA1 OOZ OmA 12 mA Max • Clear cover for convenient visual inspection., RTS151/ • Remote testing capability. RTS151 KEY OmA 12mA Max • Requires com line power only. • Accommodates the installation of an addressable relay Agency Listings and Approvals module, sold separately, (FRM-1 or NC-100R) for applica- tions requiring a Form-C relay. Consult product manual for lists of compatible UL-Listed devices. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Con- sult factory for latest listing status. • UL:S911,S3705. • ULQ S635. DN-60429:C1•4/19/2012—Page 1 of 2 • CSFM: 3242-1653:0209. • FM approved. Product Line Information NOTE:A suffix indicates ULC listed model. DNR(A): Intelligent non-relay photoelectric low flow smoke detector housing.Requires photoelectric smoke detector(sold separately). DNRW: Watertight intelligent non-relay photoelectric low flow duct smoke detector housing. Requires photoelectric smoke detector(sold separately). FSP-851R(A): Remote test capable addressable low-profile photoelectric smoke detector. FSP-851(A): Addressable low-profile photoelectric smoke detector. NP-100:Addressable low-profile photoelectric smoke detector for FireWarden series panels. NP-100R(A): Remote test capable addressable low-profile photoelectric smoke detector for FireWarden series panels. DCOIL: Remote test coil. Required for older DNR(W) duct detector housing. DST1(A):Metal sampling tube duct width up to 1 ft(0.3m). DST1.5(A): Metal sampling tube duct widths up to 1 ft to 2 ft (0.3 to 0.6 m). DST3(A):Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m). DST5(A):Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m). DST10(A): Metal sampling tube duct widths up to 8 ft to 12 ft (2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX: Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z(A):Remote annunciator alarm LED. RTS151(A): Remote test station. RTS151 KEY(A): Remote test station with key lock. Important Note • DNRW duct detector housings with a date code of 0013 or higher do not require a DCOIL or auxiliary 24 VDC for remote test applications when used with a remote test capable detector. • DNRW duct detector housings with a date code of 0012 or earlier require a DCOIL and auxiliary 24 VDC power for remote test applications. Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. 02012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1S0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. B01HEi1N111 8 MWIU 11ING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-60429:C1•4/19/2012 DN-6999:E Monitor Modules �J N OTI F 1 E R° NMM-100(A), NMM-100P(A), NZM-100(A), and NDM-100(A) for FireWarden Series by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's JA FireWarden Series intelligent control panels for a variety of applications. Monitor modules supervise a circuit of dry-con- tact input devices, such as conventional heat detectors and .Q pull stations, or monitor and power a circuit of two-wire _ _ P •M smoke detectors(NZM-100(A)). _- NMM-100(A)is a standard-sized module(typically mounts to a 4"[10.16 cm] square box)that supervises either a Style D "s`A;.,•- kc,4)n (Class A) or Style B (Class B) circuit of dry-contact input - - -- devices. — NMM-100P(A) is a miniature monitor module a mere 1.3" (3.302 cm) H x 2.75"(6.985 cm)W x 0.65"(1.651 cm) D that supervises a We B (Class B) circuit of dry-contact input devices. Its compact design allows the NMM-100P(A) to be R mounted in a single-gang box behind the device it monitors. ' 's NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire, 24 volt, smoke detectors on a Style D(Class A)or Style B(Class B)circuit. NMM-100(A)(Type H) NDM-100(A) is a standard-sized dual monitor module that monitors and supervises two independent two-wire Style B to monitor normally-open supervisory devices with special (Class B) dry-contact initiating device circuits (IDCs) at two supervisory indication at the control panel. Monitored circuit separate, consecutive addresses in intelligent, two-wire sys- may be wired as an NFPA Style B(Class B)or Style D(Class tems. I A) Initiating Device Circuit. A 47K Ohm End-of-Line Resistor LiteSpeedTm is a communication protocol that greatly (provided) terminates the Style B circuit. No resistor is increases the speed of communication between analog intel- required for supervision of the Style D circuit. ligent devices. Intelligent devices communicate in a grouped NMM-100(A) OPERATION fashion. If one of the devices within the group has new infor- mation,the panel CPU stops the group poll and concentrates Each NMM-100(A) uses one of the available module on single points. The net effect is response speed greater addresses on an SLC loop. It responds to regular polls from than five times that of other communication protocols. the control panel and reports its type and the status (open/ normal/short) of its Initiating Device Circuit (IDC). A flashing NMM-100(A) Monitor Module LED indicates that the module is in communication with the control panel. The LED latches steady on alarm (subject to • Built-in type identification automatically identifies this current limitations on the loop). device as a monitor module to the control panel. • Powered directly by two-wire SLC loop. No additional NMM-100(A)SPecrF�car�oNs power required. Nominal operating voltage: 15 to 32 VDC. • High noise(EMF/RFI)immunity. Maximum current draw:5.0 mA(LED on). • SEMS screws with clamping plates for ease of wiring. Average operating current: 375 pA(LED flashing), 1 com- • Direct-dial entry of address: 01 -99 on FireWarden-100- munication every 5 seconds,47k EOL. 2,01—50 on FireWarden-50. Maximum IDC wiring resistance: 1500 Ohms. • LED flashes during normal operation and latches on Maximum IDC Voltage: 11 Volts. steady to indicate alarm. The NMM-100(A)Monitor Module is intended for use in intel- EOL resistance:47K Ohms. ligent, two-wire systems, where the individual address of Temperature range:32•F to 120°F(0°C to 49•C). each module is selected using the built-in rotary switches. It provides either a two-wire or four-wire fault-tolerant Initiating Humidity range: 10%to 93%noncondensing. Device Circuit(IDC)for normally-open-contact fire alarm and Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x supervisory devices.The module has a panel-controlled LED 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x indicator. 2.125"(5.398 cm)deep box. NMM-100(A)APPLICATIONS Use to monitor a zone of four-wire smoke detectors, manual NMM-1 OOP(A) Mini Monitor Module fire alarm pull stations,waterflow devices, or other normally- • Built-in type identification automatically identifies this open dry-contact alarm activation devices. May also be used device as a monitor module to the panel. DN-6999:E•07/30/2015—Page 1 of 4 ^ Powered directly by two-wire 8LC loop. No additional Wire length:6'M5.24 cm) minimum. power required. ^ High noise(EMRRFVimmunity. NZM4 OO(A) Interface Module ^ Tinned,stripped leads for ease ofwiring. ^ Supports compatible two-wire smoke detectors. ^ Direct-dial entry of address:O1—S9onFineWarden-1OO-2. , Supervises |DC wiring and connection u[external power 01-50onF|neWarmen-50. . anunm./ ~ High noise(EMF/RF|)immunity. ADDRESS 0 .. ~ GEMGscrnws with clamping plates for ease of wiring. � ^ Direct-dial ofaddress:,01-99onFineWanien- � LOOP 100-2. 01-50vnFineWandon-50. ^ LED flashes during normal operation. ~ LED latches steady to indicate alarm on command from TENS ONES control panel. The OOInterface Module is intended for use i intelligent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface J __J LU and monitor two-wire conventional smoke detectors. It trans- �� u nc '� mUothe status `�m» <nnnna! open— or alarm) of one full zone of �� �� qz conventional d�a�oraback the uontm|ponuiAUhwu�ine detectors being monit ored co mpatible module. U U U U AZM-100(A) AppucAnomu TheNK8N-10UPVV Mini Monitor Module can be installed ina Use the NZN-100KV to monitor a zone oftwo+wire smoke single-gang junction di ct| behind the monitored unit. Its detectors. The monitored circuit may be wired as anNFRA small size and light weight allow it to be installed without rigid Style B (Class B) or Style D (Class A) Initiating Device Cir- mounting. The NMM-100P(A) is intended for use in intelli- cuit.A 3.9 K Ohm End-of-Line Resistor(provided)terminates gent,two-wire systems where the individual address of each the end of the Style B or D (class B or A) circuit (maximum module is selected using rotary switches. It provides a two- IDC loop resistance is 25 Ohms). Install ELR across termi- wire initiating device circult for normally-open-contact fire nals 8 and 9 for Style D application. alarm and security devices. NMM-100P(A) NZM-100(y)Opeaonqw AM0-10Of(4)AppLICAnowa Each NZM-100(A) uuoo one of the available module Use to monitor a single device ora zone of four-wire smoke addresses onan8LCloop. |t responds to regular polls from detectors, manual fire alarm pull stations,vw*terflmwdevices, the control panel andreports its type andthe status (oeV or other normally-open dry-contact devices. May also be normal/short) o[its Initiating Device Circuit(|DC). Aflashing used humonitor || aupemiuurydaviceowithupa- LED indicates that the module iein communication with the da|supervisory indication ed the control panel. Monitored cip control panel. The LED latches steady on alarm (subject hu ouiVdevice is wired as on NFPA Style B (C|oon B) Initiating current limitations nn the|oop). Device Circuit. A47K Ohm End-uf-Lina Resistor (pruvided) terminates the circuit. kZM-100(A)SpacmicAnoxs 80xM-100"(A) OpzRxnom Nominal operating voltage: 15to32VDC. Each NMN-100P(A) uses one of the available module Maximum current draw:5.1mA(LED on). addresses onanSLC loop. It responds tu regular Polls from Maximum[DC wiring resistance:25Ohms. the control panel and reports �mpea��e ��a (open/ normal/short) Initiating operating cmrms�: 270p\ 1onmmuniu�iunand - — 1 LED flash every 5 seconds,3.Skeo|. hMM-10UP(A)SpEcoicAnowy EOL resistance:3.9KOhms. Nominal operating voltage: 15tm32VDC. External supply vmDoQe (between Terminals T10 and Average operating current: 350 p\ 1 communication T11): every 5seconds, 47h EOL; 000 pAK0ox (Communicating, |DCGhuded>. ~ DC voltage:24 volts power limited. ^ Fh����go �1�mnmo�mum Maximum;DCx��ng resistance: 1500 Ohms. ' Maximum|DCVwltage' 11 Vb|� , � ' ~ Cur�n:SOmA per module maximum. Temperature range:32^Fto12O^F(O^C\o4SC). Mmumm�m����un�w�45O��-- Humidity range: 1OY60o9396nunoondonsing. EOLreoistanue'47KOhma' ' Dimensions: 4.5' (11.43cm) high x4�' (1O1O cm) wide x Temperature range:32~Fhn 120^F KrC0u4R^C>. 1.25"(3175 um) deep. Mounts to o 4' (1[\18 cm) square x Humidity range: 10Y60o9396 noncondonming. 2.125''(5.39Ocm)deep box. Dimensions: 1.3^(3.3O2 cm)high x275'(8.985 cm)wide v O.G5"<1.O51 cm)deep. NDM-100(A) Dual Monitor Module CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- The NDM-100(A) Dual Monitor Module is intended for use in 100);7300-0028:0237(NDM-100). intelligent, two-wire systems. It provides two independent two- ;MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); wire initiating device circuits(IDCs)at two separate,consecutive 227-03-E Vol.3(NDM-100). addresses.It is capable of monitoring normally open contact fire alarm and supervisory devices.The module has a single panel- Product Line Information controlled LED. NOTE:"A"suffix indicates ULC-listed model. NOTE: The NDM-100(A)provides two Style 8 (Class B) IDC cir- cuits ONLY. Style D(Class A) IDC circuits are NOT supported in+NMM-100(A): Monitor module. any application. NMM-100P(A): Monitor module, miniature. NDM-100(A)SPEcmicATioNS NZM-100(A): Monitor module,two-wire detectors. Normal operating voltage range: 15 to 32 VDC. NDM-100(A): Monitor module, dual, two independent Class Maximum current draw:6.4 mA(LED on). B circuits. Average operating current:750 pA(LED flashing). SM13500:Optional surface-mount backbox. Maximum IDC wiring resistance: 1,500 Ohms. NOTE: See installation instructions and refer to the SLC Wiring Maximum IDC Voltage: 11 Volts. Manual,PN 52304. Maximum IDC Current:240 pA EOL resistance:47K Ohms. Temperature range:32°to 120°F(0•to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. NDM-100(A)AUTOMATIC ADDRESSING The NDM-100(A)automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address"26", then it will automati- cally assign itself to addresses"26"and"27". NOTE."Ones"addresses on the NDM-100(A)are 0, Z 4, 6, or 8 only. Terminals 6 and 7 use the first address, and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A),NZM-100(A),and NDM-100(A)modules mount directly to a standard 4" (10.16 cm) square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and instal- lation instructions are provided with each module. All wiring must conform to applicable local codes, ordinances,and reg- ulations. These modules are intended for power-limited wir- ing only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electri- cal box. All wiring must conform to applicable local codes, ordinances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635. • ULC:S635. • FM Approved. DN-6999:E•07/30/2015—Page 3 of 4 Notifier®and FireWarden®are registered trademarks and LiteSpeedT and FireWatchTM are trademarks of Honeywell International Inc. ©2015 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. AIIIFE®INI I MANIFACTIRING All specifications are subject to change without notice. QUALITY SYSTEMS For more informaton,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:E•0 7/3 012 0 1 5 dn-60383:A2 NC-100R(A) NOT 1 F 1 E R® Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices, such as fans,dampers,door hold- ers, control equipment, etc.Addressability allows the dry con- tact to be activated, either manually or through panel µ programming,on a select basis. Features = • Built-in type identification automatically identifies these devices to the control panel. •�""""''" • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED "blinks" green each time a communication is —�- received from the control panel and turns on in steady when 2 activated. 's • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). I Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Norm four-wire smoke detector power. al operating voltage: 15 to 32 VDC. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll(CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 320F to 120OF(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop.It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Ratin Rotary switches set a unique address for each module. The Voltageg address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(UR=5ms) Coded 30 VDC 0.5 A Inductive(UR=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UUULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-10OR: Intelligent addressable relay module. NC-100RA:Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE. For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EVItgBUfK a MANOFAoIULIM All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383:A2.06/17110 DN-60918:A Indoor Selectable-Output N OTI F I E R® Horns, Strobes, and Horn J Strobes for Wall Applications by Honeywell Devices General The L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry with lower cur- rent draws and modern aesthetics.With white and red plastic housings, standard and small footprint devices, and plain, FIRE-printed devices, L-Series can meet virtually any applica- tion requirement. + k The L-Series product line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back P2RL box,making installations fast and foolproof while virtually elim- inating costly and time-consuming ground faults. To further simplify installation and protect devices from con- struction damage, L-Series utilizes a universal mounting plate for all standard and compact models with an onboard shorting F F spring,so installers can test wiring continuity before the device is installed. R Installers can also easily adapt devices to a suit a wide range R ,'„m^�+�:. ..• .�r���� ' '__ of application requirements using field-selectable candela set- tings, E. automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Features P2GWL SGWL • Updated modern aesthetics. • Small profile devices for Horns and Horn Strobes. --�, • Plug-in design with minimal intrusion into the back box. • Tamper-resistant construction. • Automatic selection of 12-or 24-volt operation at 15 and 30 NMI candela. ;. ar • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135,and 185. • Horn rated at 88+dBA at 16 volts. _ • Rotary switch for horn tone and two volume selections. • Universal mounting plate for all standard and all compact HWL wall units. • Mounting plate shorting spring checks wiring continuity. before device installation. • Electrically Compatible with legacy SpectrAlert® and 12 or 24 volts. When used with the Sync-Circuit Module, 12- SpectrAlert Advance devices. volt-rated notification appliance circuit outputs shall operate • Compatible with MDL3 sync module. between 8.5 and 17.5 volts; 24-volt-rated c appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor • Listed for wall mounting only. L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unaltered Architectural/Engineering Specifications power supply.Strobes and horn strobes shall have field-select- General: L-Series standard horns, strobes, and horn strobes able candela settings including 15, 30, 75, 95, 110, 135, and shall mount to a standard 2" x 4" x 17/S back box, 4" x 4" x 185. 11/2"back box,4"octagon back box,or double-gang back box. Strobe. The strobe shall be a L-Series Model listed to UL L-Series compact products shall mount to a single-gang 2" x 1971 and shall be approved for fire protective service. The 4' x 17/8" back box. A universal mounting plate shall be used strobe shall be wired as a primary-signaling notification appli- for mounting ceiling and wall products for all standard-size ance and comply with the Americans with Disabilities Act models and a separate universal mounting plate shall be used requirements for visible signaling appliances,flashing at 1 Hz for mounting compact wall models.The notification appliance over the strobe's entire operating voltage range. The strobe circuit wiring shall terminate at the universal mounting plate. light shall consist of a xenon flash tube and associated lens/ Also, L-Series products, when used with the Sync•CircuitTm reflector system. Module accessory, shall be powered from a non-coded notifi- cation appliance circuit output and shall operate on a nominal DN-60918:A•2/3/2017—Pagel of 4 Horn Strobe Combination. The horn strobe shall be a L-Series Drawings L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be Compact Horn wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visi- 3.a6 1.25 ble signaling appliances, flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(contin- Le 0 0000000 uous) pattern. These options are set by a multiple position 0 switch. The horn on horn strobe models shall operate on a 5.27 ° coded or non-coded power supply. � Synchronization Module.The module shall be a Sync•Circuit �;�model MDL3 listed to UL 464 and shall be approved for fire �'�protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three.Also,while oper- ating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411/6" x 411/16" x 21/8" back box. The module shall Compact Combo also control two Style Y(class B)circuits or one Style Z(class 1.91 A)circuit.The module shall synchronize multiple zones.Daisy 3.46 chaining two or more synchronization modules together will 1.25 synchronize all the zones they control. The module shall not operate on a coded power supply. PHYSICAUELECTR/CAL SPECIFICATIONS LCJ • Standard Operating Temperature: 32°F to 120°F (0°C to 49°C). 5.27 • Humidity Range: 10 to 93%non-condensing. • Strobe Flash Rate:1 flash per second. • Nominal Voltage: Regulated 12 DC or regulated 24 DC/ FWR1 (full wave rectified). • Operating Voltage Range2: 8 to 17.5 V (12 V nominal)or 16 to 33 V(24 V nominal). • Operating Voltage Range:MDL3 Sync Module 8.5 to 17.5 V(12 V nominal)or 16.5 to 33 V(24 V nominal). Horn • Input Terminal Wire Gauge: 12 to 18 AWG. —4.70 Wall-Mount Dimensions(including lens):5.6"L x 4.7"W 1.25 • x 1.25'D(143 mm L x 119 mm W x 32 mm D). • Compact Wall-Mount Dimensions(including lens):5.26" L x 3.46"W x 1.93"D(133 mm L x 88 mm W x 49 mm D). • Horn Dimensions:5.6" L x 4.7"W x 1.25"D(143 mm L x 5.67 • 119 mm W x 32 mm D). ��•••442 ••••• • Compact Horn Dimensions: 5.25" L x 3.45"W x 1.25" D oil (133mm L x 88mm W x 32mm D). Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time- varying power source that is used on some power supply and panel outputs. Combo 2.P,S, PC,and SC products will operate at 12 V nominal only 4.70 for 15 cd and 30 cd. 1.91 1.25 5.67 o Page 2 of 4—DN-60918:A•2/3/2017 UL Current Draw Data UL MAX.HORN CURRENT DRAW(MA RMS) UL MAX.STROBE CURRENT DRAW MA RMS 8- ( ) Voo ltslts 16-33 Volts volts 16-33 Volts Sound Pattern dB DC DC FWR Volts Candela DC DC FWR Temporal High 39 44 54 15 88 43 60 Temporal Low 28 32 54 30 143 63 83 Non-Temporal High 43 47 54 75 N/A 107 136 Non-Temporal Low 29 32 54 95 N/A 121 155 3.1 KHz Temporal High 39 41 54 110 N/A 148 179 3.1 KHz Temporal Low 29 32 54 135 N/A 172 209 3.1 KHz Non-Temporal High 42 43 54 185 N/A 222 257 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL MAX. CURRENT DRAW(MA RMS),2-WIRE HORN STROBE,CANDELA RANGE(15-115 CD) DC Input: DC Input: FWR Input: 8-17.5 Volts 16-33 Volts 16 FWR 15 30 15 30 75 95 110 135 185 15 30 75 95 111 131 111 cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd cd EM Temp Hi 98 158 54 74 121 142 162 196 245 83 107 156 177 198 234 287 EM Temp Low 93 154 44 65 111 133 157 184 235 68 91 145 165 185 223 271 EM Cont Hi 106 166 73 94 139 160 182 211 262 111 135 185 207 230 264 316 EM Cont Low 93 156 51 71 119 139 162 190 239 79 104 157 175 197 235 283 3.1 K Temp Hi 93 156 53 73 119 140 164 190 242 81 1 105 1 155 177 196 234 284 3.1 K Temp Low 91 154 45 66 112 133 160 185 235 68 90 145 166 186 222 276 3.1K Cont Hi 99 162 69 90 135 157 175 208 261 104 131 177 204 230 264 326 3.1k Cont Low 93 156 52 72 119 138 162 192 242 77 102 156 177 199 234 291 HORN TONES AND SOUND OUTPUT DATA:HORN AND HORN STROBE OUTPUT(DBA) 8-17.5 Volts 16-33 Volts Pos. Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 on-Temporal High 85 90 90 4 on-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 1 88 6 3.1 KHz Temporal Low 76 82 82 7t P.1 KHz Non-Temporal High 84 89 89 8t .1 KHz Non-Temporal Low 77 83 83 9t oded High 85 90 E90 10 .1 KHz Coded High 84 89 89 DN-60918:A•2/3/2017—Page 3 of 4 Agency Listings and Approvals The listings and approvals below apply to L-series devices. In some cases,certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. • UL/ULC-Listed —S4011 Wall Horn Strobes —S5512 Wall Strobes —S5512 Wall Horns • FM Approved Product Line Information Note: ULC-listed devices include required French labeling. See Agency Listings for listing details, WALL HORN STROBES P2WL(A),132RL(A).2-Wire, Horn Strobe(White,Red). P2GWL(A), P2GRL(A).2-Wire,Compact Horn Strobe(White, Red). P2WL(A)-P, P2RL(A)-P. 2-Wire, Horn Strobe, Plain (White, Red). 132WL-SP, P2RL-SP. 2-Wire, Horn Strobe, FUEGO (White, Red). WALL STROBES SWL(A),SRL(A).Strobe, Red(White,Red). SGWL(A),SGRL(A).Compact Strobe(White, Red). SWL(A)-P,SRL(A)-P.Strobe,Plain(White, Red). SRL-SR Strobe, FUEGO(Red). SWL-CLR-ALERT.Strobe,ALERT(White). SWL-ALERT.Strobe,Wall,Amber Lens,Alert(White). HORNS HWL(A),HRL(A).Horn(White, Red). HGWL(A),HGRL(A).Compact Horn(White, Red). ACCESSORIES TR-2W,TR-2.Universal Wall Trim Ring(White, Red). SBBWL,SBBRL.Wall Surface Mount Back Box(White, Red). SBBGWL, SBBGRL. Compact Wall Surface Mount Back Box (White,Red). Notes: • All -P models have a plain housing (no"FIRE"marking on cover). • All-SP models have"FUEGO"marking on cover. • All-ALERT models have"ALERT'marking on cover. • ULC-listed"A"models have FIRE/FEU marking on cover. NOTIFIERO and SpectrAlert® are registered trademarks and Sync-Circuit' is a trademark of Honeywell International Inc. 02017 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'SO 9oo1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 611IlESUR aMANEFACM11111 All specifications are subject to change without notice. QUALITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-60918:A•2/3/2017 SYSTEM SENSOR Outdoor Selectablem Output Horns, _ I Strobes, and Horn Strobes for Wall Applications SPECTRAlert SpectrAlertO Advance outdoor audible visible products a► o v .®► N c E are rich with features that cut installation times and maximize profits. Features SpectrAlert Advance offers the broadest line of outdoor horns, • Weatherproof per NEMA 4X, IP56 strobes,and horn strobes in the industry.With white or red plastic housings,wall or ceiling mounting options,and plain or FIRE-printed • Listed to UL 1638(strobe)and UL 464(horn) devices,SpectrAlert Advance can meet virtually any application • Compatible with System Sensor synchronization protocol and requirement,including indoor,outdoor,wet,and dry applications in legacy SpectrAlert products temperatures from_-40°F to 151*F. • Field-selectable candela settings: 15, 15/75,30,75,95, 110, 115, Like the entire SpectrAlert Advance line,outdoor horns,strobes, 135, 150, 177,and 185 and horn strobes for wall applications include a variety of features • Automatic selection of 12-or 24-volt operation at 15 and that increase application flexibility and simplify installation.First, 15/75 candela field-selectable settings,including candela,automatic selection of • Rotary switch for horn tone and three volume selections 12-or 24-volt operation,horn tones,and three volume options enable • Horn rated at 88+dBA at 16 volts installers to easily adapt devices to meet requirements. • Rated from—40°F to 151°F Next,SpectrAlert Advance devices use a universal mounting plate • Universal mounting plate with an onboard shorting spring that for both wall and ceiling applications.This mounting plate includes tests wiring continuity before devices are installed an onboard shorting spring that ensures wiring continuity before • Plug-in design with minimal intrusion into the back box devices are installed,so installers can verify proper wiring without mounting the devices and exposing them to potential construction • Tamper-resistant construction damage.Once the plates are mounted,all SpectrAlert Advance • Listed for ceiling or wall mounting devices utilize a plug-in design with a single captured screw to speed installation and virtually eliminate costly ground faults. Outdoor devices ship with weatherproof plastic back boxes(metal back boxes are available separately)that accommodate in-and- Agency Listings out wiring for daisy chaining devices.Plastic back boxes feature removable side flanges and improved resistance to saltwater SicxAuec corrosion.Knock-outs located on the back eliminate the need to drill Oholes for screw-in mounting.Plastic and metal weatherproof back U� boxes come with 3/4-inch top and bottom conduit entries and 3/-inch F M MEA 7300-1663 187(outdoor strobes) LISTED approved 7125-1663:188(horn strobes, knock-outs at the back.A screw-in NPT plug with an O-ring gasket S4011(chimes,horn strobes,horns) APPROVED pP chime strobes) S3593(outdoor and alert strobes) 3023572 MEA452-05-E 7135-1653:189(horns,chimes) for a watertight seal is included with each back box. SpectrAlert Advance Outdoor Horn,Strobe, and Horn Strobe Specifications ArchitectlEngineer Specifications General SpectrAlert Advance outdoor horns,strobes,and horn strobes shall mount to a weatherproof back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate. Also,SpectrAlert Advance products,when used with the Sync-Circuit"Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts.When used with the Sync•Circuit Module,12-volt-rated notification appliance circuit outputs shall operate between 9 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 17 and 33 volts.Outdoor SpectrAlert Advance products shall operate between-40 and 151 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply.Strobes and horn strobes shall have field-selectable candela settings including 15, 15/75,30,75,95,110, 115,135,150, 177,and 185. Strobe The strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL.The strobe shall be suitable for use in wet environments. Horn Strobe Combination The horn strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have three audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options shall be set by a multiple position switch. On four-wire products,the strobe shall be powered independently of the sounder.The horn or horn strobe models shall operate on a coded or non-coded power supply.The horn strobe must be installed with its weatherproof back box in order to remain outdoor approved per UL. The horn strobe shall be suitable for use in wet environments. PhysicallElectrical Specifications Temperature -4O°F to 151°F(-40°C to 66°C) Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC/FWR or regulated 24 DC/FWR1 Operating Voltage Range 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions(including lens) 5.6-L x 4.7-W x 2.5"D(142 mm L x 119 mm W x 64 mm D) Horn Dimensions 5.6-L x 4.7-W x 1.3-D(142 mm L x 119 mm W x 33 mm D) Wall-Mount Weatherproof Back Box Dimensions(SA-WBB) 5.7-L x 5.1-W x 2.0"-D(145 mm L x 130 mm W x 51 mm D) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 15/75 cd. AVDS01201 UL Current Draw Data UL Max.Strobe Current Draw(mA RMS) UL Max.Horn Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts 8-17.5 Volts 16-33 Volts Candela DC FWR DC FWR Sound Pattern dB DC FWR DC FWR Standard 15 123 128 66 71 Temporal High 57 55 69 75 Candela 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Range 30 NA NA 94 96 Temporal Low 38 44 44 48 75 NA NA 158 153 Non-Temporal High 57 56 69 75 95 NA NA 181 176 Non-Temporal Medium 42 50 60 69 110 NA NA 202 195 Non-Temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 High 135 NA NA 228 207 Coded Medium 44 51 56 69 Candela 150 NA NA 246 220 Coded Low 40 46 52 50 Range 177 NA NA 281 251 185 NA NA 286 258 StandardUL Max.Current Draw(mA RMS),2-Wire Horn Strobe, Range 8-17.5 Volts 16-33 Volts DC Input 15 15/75 15 15/75 30 75 95 110 115 Temporal High 137 147 79 90 107 176 194 212 218 Temporal Medium 132 144 69 80 97 157 182 201 210 Temporal Low 132 143 66 77 93 154 179 198 207 Non-Temporal High 141 152 91 100 116 176 201 221 229 Non-Temporal Medium 133 145 75 85 102 163 187 207 216 Non-Temporal Low 131 144 68 79 96 156 182 201 210 FWR Input Temporal High 136 155 88 97 112 168 190 210 218 Temporal Medium 129 152 78 88 103 160 184 202 206 Temporal Low 129 151 76 86 101 160 184 194 201 Non-Temporal High 142 161 103 112 126 181 203 221 229 Non-Temporal Medium 134 155 85 95 110 166 189 208 216 Non-Temporal Low 132 154 80 90 105 161 184 202 211 UL Max.Current Draw(mA RMS),2-Wire Horn Strobe,High Candela Range(135-185 cd) 16-33 Volts 16-33 Volts DC Input 135 150 177 185 FWR Input 135 150 177 185 Temporal High 245 259 290 297 Temporal High 215 231 258 265 Temporal Medium 235 253 288 297 Temporal Medium 209 224 250 258 Temporal Low 232 251 282 292 Temporal Low 207 221 248 256 Non-Temporal High 255 270 303 309 Non-Temporal High 233 248 275 281 Non-Temporal Medium 242 259 293 299 Non-Temporal Medium 219 232 262 267 Non-Temporal Low 238 254 291 295 Non-Temporal Low 214 229 256 262 Candela Derating Horn Tones and Sound Output Data For K series products used at low temperatures,listed Horn and Horn Strobe Output candela ratings must be reduced in accordance with 8-175 16-33 24-Volt Nominal this table. Switch Sound Volts Volts Reverberant Anechoic OutputStrobe Position Pattern dB DC FWR DC FWR DC FWR DC FWR Listed Candela Candela rating at-40'F 1 Temporal High 78 78 84 84 88 88 99 98 15 2 Temporal Medium 74 74 80 80 86 86 96 96 15/75 Do not use below 32°F 3 Temporal Low 71 73 76 76 83 80 94 89 30 4 Non- High 75 44 Temporal 82 82 88 88 93 92 100 100 95 70 5 Non- Medium 78 78 85 85 90 90 98 98 110 110 Temporal 115 115 6 Non- Low 135 135 Temporal 75 75 81 81 88 84 96 92 150 150 7t Coded High 82 82 88 88 93 92 101 101 177 1177 8t Coded Medium 78 78 85 85 90 90 97 98 185 1185 9t Coded Low 75 75 81 81 88 85 96 92 tSettings 7,8,and 9 are not available on 2-wire horn strobe. AVDS01201 SpectrAlert Advance Diagrams �4.7"� 2.5" 5.6" ° O 0 Wall-Mount Horn Strobes ® Wall Plastic Weatherproof Back Box 0 1; Wall-Mount Horn Strobe with Plastic Weatherproof Back Box SpectrAlert Advance Ordering Information Model Description Horn Strobes P2RK*t 2-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P2RHK*t 2-Wire Horn Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) P2WK*t 2-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2WHK*t 2-Wire Horn Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) P4RK1 4-Wire Horn Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) P4WK 4-Wire Horn Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) P2RHK-120 2-Wire Horn Strobe,High cd,Red,Outdoor, 120 V(includes plastic weatherproof back box) Wall Strobes SRK*t Strobe,Standard cd,Red,Outdoor(includes plastic weatherproof back box) SRHK*t Strobe,High cd,Red,Outdoor(includes plastic weatherproof back box) SWK*t Strobe,Standard cd,White,Outdoor(includes plastic weatherproof back box) SWHK*t Strobe,High cd,White,Outdoor(includes plastic weatherproof back box) Horns HRKt Horn,Red,Outdoor(includes plastic weatherproof back box) Accessories SA-WBB Red,Metal Weatherproof Back Box SA-WBBW White,Metal Weatherproof Back Box Notes: *Add"-P"to model number for plain housing(no"FIRE"marking on cover),e.g.,P2RK-P. t Add'-R"to model number for weatherproof replacement device(no back box included),only for use with weatherproof outdoor flush mounting plate,WTP and WTPW. "Standard cd"refers to strobes that include 15,15/75.30.75,95,110,and 115 candela settings."High cd"refers to strobes that include 135,150,177,and 185 candela settings.When replacing standard outdoor units both the device and back box must be replaced. SYSTEM 3825 Ohio Avenue•St ®t o c System Sensor. .Charles,IL 60174 Product speahcatlons s�rb�ec to change vntnout notice.Visa systemsensoccom SENSOR' Phone:800-SENSOR2•Fax:630-377-6495 for current product information.including tee latest version of this datasneet AVDS01201-3/12 ries �Niftjft.,Surge Protective Device l _ - DITEK's DTK-HW Series of surge protectors are designed and manufactured to meet the standards of the life safety industry. These compact, parallel-mount surge protectors are widely used to protect fire alarm panels and other dedicated branch circuit loads. ®usLISTED ® & y ;,. Part Number: K■ DTK-120HW DT -120/240HW Service Voltage: Single(2W+G), Split(3W+G), 120VAC 120/240VAC DTK-120HW MCOY: 130V 130/260V Product Features Protection Modes: L-G, L-N, N-G L-L, L-G, L-N, N-G ■Available for 120V and 120/240V systems Voltage Protection Rating: 700V L-N, L-G 700V L-N, L-G _ ■Approved for 20A circuit breakers 600V N-G 600V N-G, 1200 L-L Surge Current Rating: 18,000A 32,000A ■ Diagnostic LED indicates ground presence, system power and SPD function SCCR:. 1o,000A Nominal Discharge ■Weatherproof enclosure 3kA ,Current Ratin a ■ Small footprint enables installation in a variety of locations Mechanical Characteristics ■ Complies with ANSI/IEEE C62.41 and C62.45 Connection Method: '/<"NPT threaded fitting Category B standards Houaing: ABS Temperature Range: -40°F-185°F(-40°C-85°C) Maximum HuM11811 : 95% non-condensing Applications Dimensions: 2.83"L x 1.68'1N x 2.93"H 71.9mm x 42.7mm x 74.4mm ■ Equipment Panel Weight: 0.51b(227g) ■ Dedicated Branch Circuit Quality, Standards&Approval ------------------------------- +/A ncyApprovals: UL 1449, cUL Accessories SPD Type: SPD Type 2 ■ DIN Rail Mounting Kit—Part Number Standartls Compliance IEEE Category B DTK-DRK yyarynty: , Ten Year Limited ,e_ Every precaution has been taken to ensure that this literature is accurate and complete.DrrEK Corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. One DITEK Center 1720 Starkey Road-Largo,FL 33771 Doc.Number:SPS-100057-001 Rev 10 03/15 O MADE IN Phone:1-800-753-2345 Direct:727-812-5000 ©2015 DITEK Corp. Imp C I. I1S Technical Support:1-888-472-6100 Page 1 of 1 LISTED U. S. A. www.ditekcorp.com SCPWP DITEK's DTK-MRJ31XSCPWP is a modular "plug & play" device designed to protect fire and security system dialer circuits. This point of use surge protector can be easily installed in series with the circuit. ' Technical Specifications Servke Voltage: Ring up voltage 11 OV MCOY• 130V Clamping Voltage: 200V Product Features Protection Modes: Pin 4—Ground, Pin 5-Ground ■Single pair RJ31X dialer circuit protection with Surge Currant Rating: 9,000 Amps(8/20NS wave form) patch cord MaxContirxiousCirrent 150mA ■ RJ45 modular jack with external grounding - screw Mechanical Characteristics ■The Sneak Current Protection—SCP, 150mA self-resetting fuse protects against repeated Connection Method: RJ45 In/Out, 8 pins surges Housing: ABS Operating Temperature: -40°F-158°F(-40°C-70oC) ------------------------------ M ix-I ffi--uffil Humidity: 95%non-condensing Applications 3.0"L x 1.7"W x 1.2"H ■ Fire Alarm Dialer Circuits Dimensions: (76mm x 43mm x 30mm) ■ Burglar Alarm Dialer Circuits Weight: 4 oz. (113g) ------------------------------- Quality,Standards& Approval Accessories Agency Approvals: UL497A ■ DIN Rail Mounting Kit—Part Number DTK-DRK Warranty: Ten Year Limited Warranty Every precaution has been taken to ensure that this literature is accurate and complete.DrIEK corporation assumes no responsibility and disclaims all liability for damages resulting from the use of this information or for any errors or omissions. One DITEK Center 1720 Starkey Road-Largo,FL 33771 Doc.Number:SPS-100065-001 Rev 3 01115 MADE IN Phone:1-800-753-2345 Direct:727-812-5000 ©2015 DITEK Corp. Technical Support:1-888-472-6100 Page 1 C U� US www.ditekcorp.com I N'Rp'A U. S. A. 0 t I / 12 Volt ZO AH Rechargeable Sealed Lead Acid Battery We've Got The Power.Tm In - 0 Absorbent Glass Mat (AGM) technology for superior performance 0 Valve regulated, spill proof construction allows safe operation in any position 27. F 1 MooE� P5- Power/volume ratio yielding unrivaled energy density 12 Volc 7.0 AMP r 9w Rugged impact resistant ABS case and cover (UL94-HB) Approved for transport by air. D.O.T., I.A.T.A., F.A.A. - and C.A.B. certified • U.L. recognized under file number MH 2O845 Terminals: (mm) Performance Specifications • F1 -Quick disconnect tabs, Nominal Voltage.......................................................12 volts (6 cells) 0.187"x 0.032"-Mate with AMP.INC. FASTON"l 87" F1 Fz Nominal Capacity series I3.21 �-3.a� 20-hr. (3500 mA to 10.50 volts) ........... �� � -, 6.35 j 7.00 AH -OR - S all I4.75 ()- auT • F2-Quick disconnect tabs, 1 10-hr. (650mA to 10.50 volts) .......................................... 6.50 AH 0.250"x 0.032"-Mate ®=o.e ®=o.e 5-hr. (1.2A to 10.20 volts) ............................................. 6.00 AH with AMP.INC FASTON ' r 250"series 1-hr. (4.5A to 9.00 volts) ............................................... 4.50 AH 15-min. (14A to 9.00 volts) ..................................................3.50 AH Physical Dimensions: in (mm) I Approximate Weight ......................................... 4.80 lbs. (2.18 kg) Energy Density(20-hr. rate) ............... 1.49 W-h/in3 (90.95 W-h/1) DIDSpecific Energy(20-hr. rate) ............ 17.50 W-h/lb (38.58 W-h/kg) ® W Internal Resistance (approx.) ..................................... 23 milliohms m E> Max Discharge Current(7 Min.) ............................... 21.0 amperes Max Short-Duration Discharge Current(10 Sec.) .... 70.0 amperes of nominal capacity at 68°F (20°C) 0 T Shelf1 Month( nth(O/o1 so�rric. - 3 Months..:.................. 91°/ MODEL P HT S-1]]o F1 � H ........................................................... O iz Vuh rangy v ro 6 Months ............................................................................... 83% Le 4 -� -- t Operating Temperature Range Charge .................................................4°F (-20°C) to 122°F (50°C ) Discharge .............................................40°F (-40°C) to 140°F (60°C) Li 5.95(tl 51) W:2.56(65) L37<0'(94 HT:3x86 98 Case................................................... ....ABS Plastic Tolerances are+/-0.04 in.(+/-1 mm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers.................................PSC-12800A, 1280OA-C height dimensions.All data subject to change without notice. To ensure safe r efficient operation always refer to the latest edition of our Technical Manual,as published on our website. changeAil data subject to without notice. www.power-sonic.com i 1 • Shelf Life & Storage Discharge Characteristics 0 14.0 100 Charging is rat 100%o o 0 recess unless Ambient Temperature 20 C(68 F O tl is required. 13.0 80 j -- Charging before C 5°C use is necessary m 12.0 _ O (41°F) to help recover ts1 full capacity. «Cd 60 ; 11.0 Chagemaytai 40°C 30°C to restore fug 0.35 20°C capacity.Do not c 10.0 70 - 3 40 (104°F) (86°F) (68°Fl let batteries reach E J141t. tp this state. `m 3.5 v0 ~ 9.o Final 7.0 0 2 4 6 8 10 12 14 16 18 20 Voltage Standing Period(Months) 6.0 11 14 1.2 2.4 6 12 24 36 48 1 2 4 6 810 20 40 Discharge Time vs. Discharge Current I� min �1• h I Discharge Time 20 15 10 Life Characteristics in Stand-By Use L 5 Ambient Temperature 20°C(68'F) a Final a 100 E Voltage , 2 10.5V \� 80 CD rn 10.2V o ra A 60 N L c 40 Float Charging Voltage in g.sv \K 2.25-2.30 V/Cell 30 Q 20 C 0 E 9.O 0 1 2 3 4 10 40°C(104°F) 20oC (68°F) Years 0°C (32°F) Life Characteristics in Cyclic Use 0.35 0.70 1.4 3.5 7.0 14 120 Discharge Current(A) 100 0 80 Cycle Applications:Limit initial current to 2.1 A.Charge until battery voltage 1"a (under charge)reaches 14.4 to 14.7 volts at 68°F(200C).Hold at 14.4 to R 60 Discharge Discharge Discharge 14.7 volts until current drops to under 70mA.Battery is fully charged under these fJ Depth 100% Depth 50% Depth 30% conditions,and charger should be disconnected or switched to"float"voltage. 0 40 d 1.Discharge Current 0.2C(Final Voltage 1.7V/Cell) "Float" or"Stand-By"Service:Hold battery across constant voltage source of 20 2.Charge Current:0.1C 13.5 to 13.8 volts continuously.When held at this voltage,the battery will seek its 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) own current level and maintain itself in a fully charged condition. 0 Note:Due to the self discharge characteristics of this type of battery, it is imperative 0 200 400 600 800 1000 1200 that they be charged within 6 months of storage,otherwise permanent loss of Number of Cycles capacity might occur as a result of suffation. Power-Sonic offers a wide range of chargers suitable for batteries up to 100AH. Please refer to the Charger Selection Guide in our specification sheets for"C-Series Please refer to our website www.power-sonic.com for a complete range of useful Switch Mode Chargers"and"Transformer Type A and F Series". Please contact our downloads,such as product catalogs,material safety data sheets(MSDS),ISO Technical department for advice if you have difficulty in locating suitable models. certification,etc.. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICAL SUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1.619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1.619-661-3648 Fax:+1-650-366-3662 nagonakdes@power-sonic.com customer-service@powersonic.com support@power-sonic.com intemafionakoles@power-sonic.com CORPORATE OFFICE•7550 Panasonic Way•San Diego,CA 92154•USA•Tel:+1.619.661-2020•Fax:+1-619.661.3650 0616110 0 2016.Power-Sonic Corporation.All rights reserved.All trademarks are the property of their respective owners. oINI-7000°At-380 ����������� ��� �� ��o��« ������ m ��m���� (� �����x��� 0�y� 0�� �� ��� m�� � � �— � 0�� ��� ����������$� U������� ���� ������� �� Honeywell' K��� u n��K� xV Intelligent/Addressable Devices i General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG1 2LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. Features • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in b1color LED, which is visible through the handle of the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to • Can be surface mounted (with SB-10 or SB-1/0) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. ° Smooth dual-action design. The NOT-BG12LX ~ Meets ADAAQ onnonb and operating mechanisms guide Addressable Manual Pull Station Unam (Section 4.1,3[131>; mootsADA requirement for 5lb. maximum activation force. ° Highly visible. The BG12TRiu usually needed for semi-flush mounting with 4^ ° Attractive shape and textured finish. (10'18 cm)o'double-gang boxes(not with single-gang bmma. ~ Key reset. " |nduuou0n�Uemeoono�'ionhandle. Operation ° Optional trim ring(BG12TR). Pushing in,then pulling down on the handle it to latch position.Once latched, the word"ACT[- ° MeetsUL 38. Standard for Manually Actuated Signaling VATED" (in bright yellow)'� '----'^~-``~~~ ovve,. while 'rUoo��the hun�e 'onmdeo ,m ears at the -e'bottom o;f the the -- ' station.Tb reset the atadun simply Construction k�/and puKmodoor open. 'This action resets the handle;cloa- GUoU. door, and handle are molded uf durable pu|yuodbonato |nQ the door automatically resets the switch. material with a textured finish. Each manual otaion, on command from the ountnd pomel, sends data\o the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 -99nnNFVV2-100/NFVV2'1V0C 1 -5UhorNFV�� NF ^ Shipping Weight:3/6 oz.�7e.1sQ) 50[). ' � V�" Normal operating voltage:o*VDC. ~ Maximum SLC loop voltage:uu.0voC. Architectural/Engineering ^ Maximum SILCstandby current:375pA. Specifications ^ Maximum SILC alarm current:smA. Manual Fire Alarm Stations shall banon-coded' with om,y ° Temperature Range:3e°Fon120°F(o^Cm49°0) operated reset lock)n order that they may be tested, and an " Relative Humidity: 1nY6»oe8%(noncondunoing) designed that after actual Emergency Operation, they m ^ For use indoors Iwa dry location ~~restored~normal except by use of=key.~v/operated sta- tion oheU eumm0000|ly condition itself on as to be visually detected aaactivatou Manu�s��onaah�| beonnauumad/� Installation reu�o|oreupu|yca--nate material with clearly visible opnuat- Tko NOT-BG12LX will mount semi-flush into a oingle'gang, inA in«x/mxi«»a provided on the cover. The word FIRE shall doub|e-gang.orotundand4^(1V.18 cm)square electrical outlet appear o»the front uf the stations in white letters, 1.OVinches box, or will surface mount m the model G8-10orSB'yOaur- (2'54 «m) or larger. Stations mhoU be suitable for surface hyoe backbox. If the N[rFBG12LK is being semi-flush mounting»»matching baokbuxS8'1OorGB'|K];orsemi-flush mnun»ad, than the optional trim ring (BG12TR) may be used. mounting on a standard oingle-gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops.The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-UO:Surface backbox;plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UUULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol.IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERO is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I�O �oo� This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. SVIINE31NI 6 M1111EFACTEAIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:13•4/13/2012