18-20094
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20094 FIRE SPRINKLER SYSTEM PERMIT PERMIT INFORMATION - LOCATION-INFORMATION.- Permit Number: 20094/19892 Address: 36763 EILAND BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 04-26-21-0000-00100-0060 Improv. Cost: 71,000.00 OWNER INFORMATION Date Issued: 10/05/2018 Name: FLORIDA MEDICAL CLINIC Total Fees: 225.00 Address: 38135 MARKET SQ Amount Paid: 225.00 ZEPHYRHILLS FL 33542 Date Paid: 10/05/2018 Phone: 813-780-8440 Work Desc: INSTALLATION FIRE SPRINKLER-MEDICAL OFFICE CONTRACTORS APPLICATION FEES BENEFICIAL FIRE PROTECTION INC FIRE SPRINKLER SYS 50.00 FIRE SPRINKLER SYS 50.00 FIRE INSPECTION FEES 45.00 FIRE PLAN REVIEW FEES 50.00 CONTRACTOR CERTIFICATE 30.00 Ins ections Required FIRE-PRESSURE TEST FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE UCORDIPIG YOUR NOTICE OF COMMEN ENT." CONTRACTOR SIGNATURE PERMIT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application ` 2 Date Received Phone Contact for Permit Owner's Name 6h1 L /- C Owner's Phone Number Owner's Address a k / Sm af iT— sA vt,a Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address p /I' Job Address C�l /¢''�� �L6�'✓', (i£ /L /G`L �' Lot# Sub Division Parcel# D'7" -.' -2 —6000—00/60— Q 77_ (OBTAINE—FROM:P-ROP_ERT_Y.TAX:N Off ICE) - - FJ Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Burn Hood Installation Emergency Generator<30 kw, LP/Natural Gas-Installatior Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale rotection Maintenance-ANNUAL Places of Assembly-ANNUAL Qtrl Semi An Sprinkler � ❑ ❑ Recreational Bum 1 Fire Alarm El ❑ ❑ ❑ ers Hood Cleaning ❑ ❑ ❑ ti ll t I t Sprinkler System Installations p y �V Hood Suppression ❑ ❑ ❑ ipes prinkler Sys) Fire Alarm Installation Torch Roofing/Tar Kettle v Fire Pumps Waste Tire Storage ANNUAL Flammable Application-ANNUAL (D 00 Valuation of Project Fuel Tanks Other: ��✓fTi6 >/L �-I a LEA" ��`' /�G :'YI�/ji c.4' o /C G Contractor Company C/ //LLB Signature Registered N i Fee Current Y/N Address ut f �741 4I 1 License# $ O�"��Z®CP ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N J Fee Current Address License# OTHER Company Signature Registered I Y/N Fee Current Y/N Address License# Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000: Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTO Subscribed and sworn to(or affirmed)before me this Subs ribed and swor to(or affirmed) efore me this by by Who is/are personally known to me or has/have produced Who is/are p rsonally known to me or has/have produced as identification. L) //i`P/C // as identification. Notary Public 91Z.141'/'/ F &�D 6d ,& Notary Public Commission No. Commission No. 66— 06,1�3 42 Z�e_bro Fl�r./ia e_ e491 -f Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �;....;„�••. DEBRAELAINE RUFFEL <. ;Commission#GG 045343 ?p.,••, r o Expires November 7,2020 Bonded Thru Troy Fain Insurance 800-385-7019 jtXt81IIH City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Horneowner: 1 � & -P-04 4-1., Date Received: Site: 3 l'a rl la4 Permit Type: Ivc , l lr n 64e,,� Approved w/no comments:2�/ Approved w/the below comments: EJ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Gene Brown—Fire Safety Officer Date Contractor and/or Homeowner (Required when comments are present) ZEPHYRHILLS FIRE DEPARTMENT 38410.6th Aye.Zephyrhills,FL• 33542 FIRE.SERVICE'USER FEES increase 1/112018 Occupancy No:: .., Plan No:: Contractors Business Name:." Billing Address: Business Address: Business Phone No.'. : ` (j` ICA3 Billing Phone.No:: Business fax No::. . . Billing Fax No.: Contact: Contact-. ' • PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual : . Education,healthcare,De " tention&Correctional. Public Assembly,Business,: schools, S. torage,,Mercantile and Churches , Site Plan: N/C Industrial. no charge Sprinkler -$60 _ Multi-Family/Commercial " .03 sf" up.to 800 sq ft $" .24.00" . Standpipes $50 (Minimum Charge$24;00 801 -1,500 sq ft: $ 34.52 Fire Pump.: $50 E] Plan Revisions. DBL. 1,501-72,500 sq.ft: $: . 60:02" Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm SPRINKLER SYSTEMS 3,501-5,000 sq ft: $. 1,27.52 . LP Gas " $50 . 0-25 Heads $50 5,501-7,500 sq ft : $: ', 187.52 Natural Gas : ' $60-.: . 26 plus Heads $100 7,501-10,000 sq ft $ 262.52 Fuel Tanks- per tank " $50 TAN SYSTEM 10,001=15;000 sq ft $ R5..02 Sparklers. $100 . ® P is $50 15,001-20,000 sq ft. $. 525.02 - Fire Works" $500 FIRE P P. 20,001-30,000 sq ft $ 750:02 Camp Fire(recreation' .$25 E Per Pump .,.$100 . 30,001-40,000 sq ft .$ :1',050.02 . " Controlled.Bum(15da.. $100. FIRE ALARM.SYSTEM. 40,001-60,000.sq ft $.1,500.02. Hood/Duct $50 0-26 Devices: : $50 " : 60,001-80,000 sq ft. $ 2,100.02 Place"of Assembly $50 Annual 80,001-($2,100.02)per. 26 plus Devices: $100 eo add 1,000sq ft $ 0.06 Fire Protection $25. . " •SUPPRESSION SYSTEMS (Business closed until. Flammable Application $50 Annual Wet $5.0 violations corrected) Waste Tire Storage $60 Annual Dry .$50, - -SPRINKLER SYSTEMS Generator<KW. . . $100. , CO2 $56 : Hydro.Undergrounds $45 . Generator KW $100- Other. $50 Hydrostatic Test $65 _ :Per system: Bio-Hazard.Waste: $100 Annual KITCHEN EXHAUST .Acceptance Test $45 per system Fumigation Ten,'ting $50" El. $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50. Annual BLP Installation per tank: $50 FIRE ALARM SYSTEM " Fuel Tank Installation $50. System Acceptance $50, Per Tank $50 Recall Acceptance $50 ❑Natural Gas Installation $50" OTHER . (Per System) Fire Wall/Smoke"Wall $15. perwalr Spray Booth $50 LP Gas $25 per tarik. 'Natural Gas $25 " per system .Tent 10'z10'or greater $15 pertent. Fire Pump. $45 . . „F• ire Suppression $30 System. Acceptance. . . . . . ." Exhaust Hood/Duct : " . . .$80 Re-inspection . DBL (other than annual) Inspection scheduled DBL and cancelled less than 24 hours .eConstruction Insp. N/C Emergency Vehicle.Acce .$50--- PLAN � STOTAL Sib INSPECTION"TOTAL PERMIT TOTAL [ . . 'GRAND.TOTAL4. .: . . -Comments: Date: $•AS..j:f : Inspector: -. see back filh � I I . . I . . FALSE.ALARM FEE. I.. 1st Alarm N/C 2nd Alarm N/C. . : . 3rd Alarm. N/C 4th Alarm. $100 . :5th Alarm $150 6th Alarm $200. NON COMPLIANCE $150 Cont.Annual Inspection.Fees 3-11.Units price per unit. $ 5.36 12-25,Units price per unit $ 4:82 26-50 Units price per unit. $ 4.29: 517100 Units price per unit $ 3.75 I. 100 or-more Units price per unit $ 2.68 Fire Safety_re-inspection.types First Re-inspectioi . N/C . Second re-inspect .$75 . Third re=inspectior $ 125.00 Inspection scheduled but cancelled 24 hrs $ 50.00 I 1 . 1 j . I TOTAL .nlr, SUBMITTAL DATA FOR: FLORIDA MEDICAL CLINIC 36757 EILAND BLVD. ZEPHYRHILLS, FLORIDA JULY 6, 2018 BENEFICIAL FIRE PROTECTION, INC. 12522 US Highway 301 N. Suite 1 Thonotosassa, Florida 33592 Phone: (813) 986-5819 Fax: (813) 986-5837 State Certification: #45018800011989 State Certification: #67451300012005 INDEX SPRINKLER HEADS: Globe'/2" QR 155'White Semi-Recessed Pendent GL5601 --5.6 K-Factor Globe 3/a" QR 155' Brass Upright GL5615 -- 5.6 K-Factor Globe 1/z" QR 155' White Concealed Pendent GL5606 -- 5.6 K-Factor Globe 1/z" QR 200' White Concealed Dry Pendent GL5634—5.6 K-Factor PIPE: Black Thinwall Pipe Black Schedule 40 Pipe Black Schedule 40 Pipe VALVES: Butterfly Control Valve Riser Check Valve Dry Pipe Valve Globe Valve Angle Valve FITTINGS: Threaded Fittings Grooved Fittings Welded Fittings MISC: Hanger Rings Hanger Fasteners Flow Switch Pressure Switch Air Compressor Electric Bell QUICK RESPONSE AUTOMATIC SPRINKLERS ■' " GL SERIES UPRIGHT• PENDENT HKC rKINUL 4Orymi in VERTICAL SIDEWALL HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION CONVENTIONAL (OLD STYLE) The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approxi- mately six times faster than ordinary sprinklers. While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles,orifices, temperature ratings and finishes to meet many varying design require- ` ments. Quick Response Sprinklers should be used advisedly and under _ the direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating QUICK RESPONSE assembly is a hermetically sealed frangible glass ampule that contains UPRIGHT CONVENTIONAL a precisely measured amount of fluid. When heat is absorbed,the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending , upon the deflector style used. 1 The sprinkler and escutcheon are not factory assembled. As- sembly is done in the field. TECHNICAL DATA QUICK RESPONSE •See reverse side for Approvals and Specifications. PENDENT VERTICAL •Temperature Ratings - 1350F (570C), 1550F (680C), 175°F (790C), SIDEWALL 200OF (930C), 286°F (141°C). •Water Working Pressure Rating - 175 psi (12 Bars). • Factory tested hydrostatically to 500 psi (34 Bars). •Maximum low temperature glass bulb rating is -670F (-550C). • Frame - bronze • Deflector - brass • Screw - brass d •Bulb seat - copper • Spring - nickel alloy • Seal - teflon • Bulb - glass with alcohol based solution, 3mm size. QUICK RESPONSE HORIZONTAL SIDEWALL • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER E BULB N.F.P.A. MAXIMUM TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 135{F[�1,t55•,F57�C/68 C ::' ORANGE/RED38_C '0.� ! 4S,yk �s ,'w..' .._.. �a'w}""•,N�w INTERMEDIATE "175°FV266.- 4D' ;479°C/93°C.- YELLOW/GREEN °C <* : HIGH 286°.F 141°C BLUE 225°F = 107r C-,; , 4077AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 FAX989-846-9231 DECEMBER 2006 A-20 BULLETIN GL5615, REV.#6 e QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT• PENDENT• VERTICAL SIDEWALL HORIZONTAL SIDEWALL e CONVENTIONAL (OLD STYLE SPECIFICATIONS NOMINAL"K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester 3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. 9 AVAILABLE AS cULus LISTED CORROSION APPROVALS RESISTANT WHEN SPECIFIED ON ORDER. STYLE SIN K 135°F 155°F 175°F 200°F 286°F NYC-DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C cULus F.M. LPC CE MEA101-92-E GL2815 2.8 X X X X X X --- --- --- X GL4215 4.2 X X X X X X --- -- -- X UPRIGHT GL5615 5.6 X X X X X X X X X X GL8115 7.8' X X X X X X X -- X GL8118 8.1 X X X X X X X X X X GL2801 2.8 X X X X X X --- - X GL4201 4.2 X X X X X X --- --- --- X PENDENT GL5601 5.6 X X X X X X X X X X GL8101 7.8' X X X X X X X --- -- X GL8106 8.1 X X X X X X X X X X VERTICAL GL5632 5.6 X X X X X X X -- -- SIDEWALL GL8133 8.1 X X X X X X --- -- -- -- GL2826 2.8 X X X X X X --- -- -- X HORIZONTAL GL4226 4.2 X X X X X X --- --- -- X SIDEWALL§ GL5626 5.6 X X X X X X X -- -- X GL8127 8.1 X X X X X X --- --- -- -- CONVENTIONAL GL5624 5.6 X X X X X - X X -- (OLD STYLE) GL8125 8.1 X X X X X --- --- X X -- s HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING,FM APPROVED 4"TO 6". t VERTICAL SIDEWALL SPRINKLER cULus LISTED FOR LIGHT HAZARD ONLY. PENDENT VERTICAL SIDEWALL cULus LISTED FOR V MIN.SPACING. UPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9'MIN.SPACING. ORDERING INFORMATION *1/2"NPT. SPECIFY GLOBE@ PRODUCT WARRANTY •Quantity • Model Number • Style Globe agrees to repair or replace any of its own ,Orifice • Thread Sizes • Temperature manufactured products found to be defective in mate- •Finishes desired rial or workmanship for a period of one year from date -Quantity-Wrenches - P/N 325390 (1/2"); of shipment. P/N 312366 (L.O.) For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 10&&Zb= 989-846-4583 FAX 989-846-9231 FIRE SPRINKLED CORPORATION 1-800-248-0278 www.globesprinkler.com DECEMBER 2006 PRINTED U.S.A. BULLETIN GL5615, REV.#6 "THE INCH"' 1b113 QUICK RESPONSE AUTOMATIC SPRINKLERS MODEL GL5606 FIRE SPRINKLER CORPORATION ONE INCH ADJUSTABLE DESCRIPTION AND OPERATION CONCEALED PENDENT The Globe Quick Response GL5606 Adjustable Concealed Pendent Sprinkler has a low profile, aesthetically pleasing design. It provides sprinkler operation approximately six times faster than ordinary sprinklers and can be installed wherever standard concealed spray sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and should be used advisedly and under the direction of approving authorities having jurisdiction. The sprinkler is available with a nominal 1"of adjustment and a low profile cover plate assembly. All that is seen at the ceiling is a 3 5/16"diameter ceiling plate or an optional 2W diameter ceiling plate color finished to match the specifier's exact requirements. The GL Series Concealed Sprinkler may be virtually invisible as it does not interrupt the"smooth flow" of the ceiling. Globe's Concealed Sprinkler utilizes its 3mm frangible glass ampule which is located above the ceiling and concealed from view by the ceiling plate. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench.The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on -screw off' designed cover plate is easily installed and with a nominal 1" inch of adjustment makes it easier to get a proper fit at the ceiling. Operation of the sprinkler occurs when heat build up causes the solder holding the cover plate to the support shell to melt allowing the cover plate to fall clear. Continued heat build up causes the 3mm glass bulb to burst allowing the deflector to drop down and distribute water in an approved pattern to extinguish or control the fire. TECHNICAL DATA •See reverse side for Approvals and Specifications. •Temperature Ratings- A-- t- ---� 135'F (57°C) Sprinkler, 1350F (57°C) Cover Plate; 1550F (68°C) Sprinkler, 1350F (57°C) Cover Plate; 155OF (68°C) Sprinkler, 155°F (68°C) Cover Plate; 3 5116"diameterplate 1750F (79°C) Sprinkler, 155OF (68°C) Cover Plate; 200°F (93°C)Sprinkler, 1550F (68°C) Cover Plate. •Water Working Pressure Rating - 175 psi (12 Bars). •Factory tested hydrostatically to 500 psi (34 Bars). MW •Maximum low temperature glass bulb rating is-670F (-550C). •Frame - bronze • Deflector- brass • Screw- brass •Bulb seat-brass • Spring - nickel alloy • Seal -teflon 2 314"diameter plate •Bulb -glass with alcohol based solution, 3mm size. QUICK RESPONSE •Drop Pin -stainless steel WHITE ADJUSTABLE •Cover Plate - brass CONCEALED PENDENT *Upper Escutcheon Assembly- plated steel. (VOTE. Globe's wrench P/N 332765 must be used to install this sprinkler. • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE BULB N.F.P.A. MAXIMUM CEILING SPRINKLER TEMPERATURES COLOR TEMPERATURE ORDINARY 13�6?�FQ% 56y°F 57,p68°C ORANGE/RED 1OQ'F= „`: 38 C .y y9M- -L .S"... • '.. i r ...7.. _ry,'P.:< _ �q 1, q._.:•.. INTERMEDIATE 175,°F7200'F 79°C/93°6 it YELLOW/GREEN 150°F 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 (989)846-4583 • FAX 989-846-9231 JULY 2009 A-38 BULLETIN GL5606 REV#5 QUICK RESPONSE AUTOMATIC SPRINKLERS MODEL GL5606 ADJUSTABLE CONCEALED PENDENT SPECIFICATIONS NOMINAL"ITC'FACTOR THREAD SIZE LENGTH FINISHES Bright Chrome White Painted 5.6 (80 metric) 1/2"NPT 2 1/2"(6.4 cm) Bright Brass' Satin Chrome' Other Painted Finishes' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. APPROVALS 135•F(57•C) 155"F(68•C) 155•F(68•C) 175•F(79•C) 200•F(93•C) STYLE SIN K with plate with plate with plate with plate with plate cULus *FM NYC-DOB MODEL FACTOR MEA101-92•E 135"F(57"C) 135•F(57•C) 155•F(68•C) 155"F(68•C) 155•F(68•C) Adjustable Concealed GL5606 5.6 X X X X X X X X Pendent *FM APPROVED AS STANDARD RESPONSE CROSS SECTION 1 7/8" 1 7/8" DIA. DIA. 1"X 1/2" 1"x 1/2" REDUCER REDUCER Cu Cu DEFLECTOR ee DEFLECTOR DROP PIN ' p DROP PIN OL 2 3/4"MAX SUPPORT 9 ' 6 1 7/8"MIN. SUSS°LL SHELL CEILING COVER PLA 1/8" 1/6"� CEILING COVER PLATE 2 3/4" 3 5/16-__T_ OPTIONAL COVER WHITE 135•F WHITE 155°F CHROME 135°F CHROME 155•F PLATE SIZE PART# PART# PART# PART# 2 3/4" 332726 332731 332724 332729 35/16" 332706 332711 332704 332709 ORDERING INFORMATION GLOBE® PRODUCT WARRANTY SPECIFY Globe agrees to repair or replace any of its own •Quantity • Model Number • Style manufactured products found to be defective in mate- •Orifice • Thread Sizes • Temperature rial or workmanship for a period of one year from date •Finishes desired of shipment. •Quantity-Adjustable Concealed Wrenches - For specific details of our warranty, please refer to P/N 332765 Price List Terms and Conditions of Sale(Our Price List). L4)13E 4 97879 I846A 83 F DRIVE, IAX989-846 9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com JULY2009 PRINTED U.S.A. BULLETIN GL5606 REV#5 "THE INCH" G �,.. QUICK RESPONSE AUTOMATIC SPRINKLERS FIRE SPRINKLER CORPORATION GL SERIES DRY TYPE ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Adjustable Concealed Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. All that is seen at the ceiling is a 3 5/16" diameter ceiling plate color finished to match the specifier's exact requirements. The Quick Response GL Series Dry Adjustable Concealed Sprinkler may be virtually invisible as it does not interrupt the "smooth flow" of the ceiling. The quick response sprinkler with operation approximately six times faster than ordinary sprinklers, should be used advisedly and under the direction of approving authorities having jurisdiction. Globe's Dry Adjustable Concealed Sprinkler utilizes its frangible 3mm glass bulb type sprinkler which is located above the ceiling and concealed from view by the ceiling plate. The plate is soldered to the sprinkler special upper support assembly in three places. Upon the application of sufficient heat,the plate falls to the floor exposing the pendent spray sprinkler. At the ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move allowing the spring assembly to pivot alongside the inner tube. At this time, water flows through the sprinkler and is distributed by the deflector in an approved discharge pattern. The provided protective cap needs to be removed in order to install the sprinkler with the proper wrench. The protective cap must be replaced on the sprinkler until the time the cover plate is to be installed. The "push on-screw off'designed cover plate is easily installed and with a nominal 1"inch of adjustment makes it easier to get a proper fit at the ceiling. TECHNICAL DATA -See reverse side for Approvals and Specifications. ®Temperature Ratings - ' 135°F (57°C)Sprinkler, 1350F (57°C) Cover Plate 155°F (68°C) Sprinkler; 1350F (57°C) Cover Plate 1750F (79°C) Sprinkler; 1550F (68°C) Cover Plate 200OF (93°C) Sprinkler; 1550F (68°C) Cover Plate i -Water Working Pressure Rating - 175 psi (12 Bars) ®Factory tested hydrostatically to 500 psi (34 Bars) , -Maximum low temperature glass bulb rating is -670F (-55°C) =_ Frame- bronze o Deflector- brass- Screw- brass - Bulb Seat- brass -Spring - nickel alloy-Seal -teflon ° Retainer- brass° Pin -stainless steel Torsion Spring -stainless steel o Lodgement Wire -stainless steel -Bulb - glass with alcohol based solution, 3mm size• Orifice Insert- brass QUICK RESPONSE °1"NPT- Outer Tube - galvanized steel pipe • Inner Tube - stainless steel FLAT PLATE DRY -Cover Plate - brass •Upper Escutcheon Assembly- plated steel CONCEALED PENDENT NOTE: Globe's wrench P/N 337014 must be used to install this sprinkler. •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N•F.P.A.MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY 135'F/155°F 57°C/68°C ORANGE/RED 100°F 36°C INTERMEDIATE 1751F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C JULY 2014 A-54 BULLETIN GL5634,REV.#1 "THE INCH" QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES DRY TYPE ONE INCH ADJUSTABLE FLAT PLATE CONCEALED PENDENT SPECIFICATIONS SIN MODEL NOMINAL THREAD SIZE LENGTH FLAT COVER "K"FACTOR PLATE FINISHES GL5634 5.6(80 metric) cULus Variable to 48" Chrome 1"NPT FM Variable to 36" White Painted GL8134 8.1 (116 metric) Other Painted Finishes'-' NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. 'FORPAINTED PLATES OTHER THAN WHITE,CONTACT GLOBE FOR ORDERING SPECIFICATIONS. APPROVALS TEMPERATURE **135°F(57°C) 155°F(68°C) -175°F(79°C) 200°F(93°C) MIN.DISTANCE STYLE SIN HAZARD' Sprinkler with Sprinkler with Sprinkler with Sprinkler with BETWEEN cULus *FM MODEL 135°F(57°C) 135°F(57°C) 155°F(68°C) 155°F(68°C) SPRINKLERS Flat Cover Flat Cover Flat Cover Flat Cover Feet(Meters) Plate Plate Plate Plate Adjustable GL5634 LH/OH X X X X X X Concealed 6(1.8) Pendent GL8134 LH/OH X X X X X --- 'SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. *FM APPROVED AS STANDARD RESPONSE *NO FM APPROVALS OR ORDINARY HAZARD LH:LIGHT HAZARD CROSS SECTION IMPORTANT INSTALLATION DATA --- -- Globe GL Series Dry Concealed sprinklers should TEE IMIG ANSI BI6.3 CIlS5155 be installed in accordance with the requirements set I I °r I AN51BI6.4�A45175 forth in NFPA 13.These sprinklers are to be installed FACE OF using a pipe wrench applied to the outer tube. When Fr TEEmNG '--� 'i'--' this is not possible,the proper sprinkler head wrench I may be used with extreme care for lengths up to approximately 18". Excessive force may distort the frame thus destroying the unit. When installed in a wet system extending into a freezing area see chart on Dry Caution sheet 9 u4 •" for minimum exposed barrel length to prevent MW. (FACE OF FDN.G TO ice plugs. Please refer to our Dry Caution Sheet for FW>9mm`BG' CUP-, OV further important installation data. 5/LORDERING INFORMATION TDRTo 1AX. °�� MA%. SPECIFY I51161 •Quantity•Model Number°Style •Orifice•Temperature•Finishes desired MUNG 35/16•DIA •Quantity-Wrenches-P/N 337014 muNG COVER PLATE •Quantity-Protective Caps-P/N 332868 1"ADJUSTMENT FLAT PLATE CONCEALED PENDENT GLOBE®PRODUCT WARRANTY FLAT COVER Globe agrees to repair or replace any of its own manufactured PLATE SIZE 135°F(57°C)PART# 155°F(68-C)PART# products found to be defective in material or workmanship for a 3 5116"DIA. period of one year from date of shipment. WHITE 332892 332898 For specific details of our warranty please refer to Price List CHROME 332891 332897 Terms and Conditions of Sale(Our Price List). 4077AIRPARK DRIVE,STANDISH,MICHIGAN 48658 GL613E 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com JULY 2014 PRINTED U.S.A. BULLETIN GL5634,REV.#1 Dyna-Flow' :- High .I'r i ,r; p • Exceptional hydraulics • Lightweight and easy to NPS Nominal I.D. Wt. Wt.(H20 Filled) CRR install In;mm In;mm Lbs/Ft;Ulm Lbs/Ft;k /m Unthreaded 1" 1.191 0.830 1.31 2.41 • Available factory roll 25 30.3 1.2 1.95 - grooved 1114" 1.536 1.059 1.87 1.55 32 39.0 1.6 2.78 - • ABFII coated I® 11k" 1.728 1.667 2.71 3.44 UL and cUL listed 40 43.9 2.5 4.03 - • 2" 2.203 2.104 3.79 2.78 • FM approved 50 56.0 3.1 5.64 - 21/2" 2.703 2.564 5.10 1.60 -65 68.7 3.8 7.59 - O The original high-strength 3" 3.314 3.387 7.18 1.48 light wall sprinkler pipe 75 84.2 5.0 10.69 with superior hydraulics. 4" 4.310 4.473 10.86 1.00 100 109.5 6.7 16.16 - Dyna-Flow°-ABFII is the"original" high-strength light wall sprinkler pipe. FM With outstanding hydraulic capabilities, APPRDYED Dyna-Flow is recognized as the most Superior Coating O American Made popular alternative to Schedule-10 pipe. Able to meet"Buy American"requirements, Lightweight and easy to cut, Dyna-Flow Dyna-Flow products are coated with an and is available through distributors in the is a valuable addition to an fire environmentally approved and specially Y USA,Canada,Mexico and Latin America. protection system. formulated modified-acrylic or water-based coating.This durable coating is paintable With an inside diameter(ID)up to 11% and acts as an excellent primer while O Specifications &Approvals larger than Schedule-40 and up to 7% resisting weather and UV degradation Dyna-Flow pipe is manufactured to meet larger than Schedule-10,Dyna-Flow from outdoor storage. ASTM A-795 Type E,Grade A and is in pipe hydraulics are exceptional. compliance with NFPA-13 and NFPA-14. Larger ID's enable Dyna-Flow and related The internal surface of all black Allied Tube All sizes of Dyna-Flow are UL and cUL components to be down-sized within the &Conduit Fire Sprinkler pipe products listed and FM approved. system,increasing the potential for job up to 4.500" in diameter is coated with our new Antibacterial Formula,"ABFII". Dyna-Flow is UL and cUL listed for use cost savings.For complete Hazen Williams with roll grooved, lain end and welded charts,refer to"Dyna-Flow Hydraulic In scientific laboratory tests,ABFII proved 9 P Data Tables". to have superior resistance to microbial joints for wet,dry,pre-action and deluge colonization of pipe walls,thereby systems.It is FM approved for roll grooved, Dyna-Flow pipe has metallurgical inhibiting or possibly preventing the onset plain end and welded joints for wet properties that provide excellent of Microbiologically Influenced Corrosion systems.Dyna-Flow is available"hot-dip" fabrication characteristics for end prep (MIC)upon installation and the first 25 galvanized"and has been specifically finishes,welding and roll grooving. flushes of the fire sprinkler system.* approved by FM for dry system uses. There are no special processes or Dyna-Flow complies with NFPA 13 and is equipment needed for fabrication rated at 300 psi working pressure. and installation. 'SeeABFlI warranty **must be ordered in 10 bundle increments 0-rdliedCustomer Service (800)882-5543 Fax: (800) 659-7730 www.alliedtube-sprinkler.com •16100 S Lathrop Ave. •11350 Norcom Rd. •2525 N 27th Ave. •600 Dean Sievers Place TUBE&CONDUIT* Harvey,IL 60426 Philadelphia,PA 19154 Phoenix,AZ 85009 Morrisville,PA 19067 02008-10 Tyco Int.,All Rights Reserved,STP-S2-3-1001 n R � � a • allied TUBE & CONDUIT c+� JA SCHE LE = 10/ 40 'x I J rim - du U ft. - dut'l- ol '&/, M Fully Listed and FM Approved Sprinkler Pipe When you specify Schedule-10/Schedule-40 sprinkler pipe you get a UL listed and FM approved product.Although these products do not require separate approvals,Schedule-10/Schedule-40 gives you the extra quality assurance you demand. Our Sch-10(11/4"-8")pipe and Sch-40(1"-2'/2")pipe have passed the same thorough lab testing as our other listed pipe products, and receive periodic mill inspections from both UL and FM agents to ensure consistent quality. Galvanized Pipe Sch-40 Specifications Schedule-10/Schedule-40 product can be NPS Nominal I.D. Wt. Wt.(1120 Filled) Pcs/ Wt/Lift(21') WtlLlft(24') W1/Lift(25') In;mm In,mm Lbs/Ft•Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg "hot-dip"galvanized to meet FM 1" 1.049 1.680 2.05 70 2,470 2,822 2,940 requirements for dry systems in accordance with the zinc coating 25 26.6 2.5 3.05 70 1,120 1,280 1,334 specifications of ASTM A-123. 1'/4" 1.380 2.270 2.93 51 2,431 2,778 2,894 32 35.1 4.36 4.36 51 1,103 1,260 1,313 Superior Coating 1'/2" 1.610 2.720 3.61 44 2,513 2,872 2,992 40 40.9 4.0 5.37 44 1,140 1,303 1,357 Our advanced formula mill coating of- 2° 2.067 3.650 5.13 30 2,300 2,628 2,738 fers a clean,durable surface.It is also 50 52.5 5.4 7.63 30 1,043 1,192 1,242 paint-ready for custom color applications 2,/2" 2.469 5.790 7.86 19 2,310 2,640 2,750 without special preparation. 65 62.7 8.6 11.73 19 1,048 1,197 1,247 The internal surface of all black Allied Tube&Conduit Fire Sprinkler pipe Sch-10 Specifications products up to 4.5000"in diameter is coated with our new Antibacterial For- NPS Nominal I.D. Wt. Wt.(H20 Filled) Pcs/ WflLift(21') WKift(24') WVLift(25') mula,"ABF".In scientific laboratory In;mm In;mm Lbs/Ft,Kg/m Lbs/Ft;Kg/m Lift Lbs;Kg Lbs;Kg Lbs;Kg test,ABS proved to have superior resis- 1" 1.097 1.400 1.81 91 2,675 3,053 3,185 tance to microbial colonization of pipe 25 27.9 2.1 2.70 91 1,213 1,385 1,445 walls,thereby delaying or possibly pre- 1'/4" 1.442 1.810 2.52 61 2,319 2,664 2,760 venting the onset of Microbiologically 32 36.6 2.7 3.75 61 1,052 1,208 1,252 Influenced corrosion(MIC)when the 1'/2" 1.682 2.080 3.04 61 2,664 3,045 3,172 First Sprinkler System is first installed. 40 42.7 3.1 4.52 61 1,208 1,381 1,439 American • 2" 2.157 2.640 4.22 37 2,051 2,344 2,442 50 54.8 3.9 6.28 37 930 1,063 1,108 Meets"Buy American"requirement 21/2" 2.635 3.530 5.89 30 2,224 2,542 2,648 and is available through distributors in 65 66.9 5.3 8.77 30 1,009 1,153 1,201 the USA,Canada and Mexico. 3" 3.260 4.330 7.94 19 1,728 1,975 2,057 Specifications & Approvals 80 82.8 6.4 11.82 19 784 896 933 4" 4.260 5.610 11.78 19 2,238 2,558 2,665 Schedule-10/Schedule-40 pipe are in 90 108.2 8.3 17.53 19 1,015 1,160 1,209 compliance with the following: T 5.295 7.77 17.33 10 1,632 1,865 1,943 125 134.5 11.56 25.80 10 740 846 881 ASTM A-135,and NFPA 13.Both pipe 6" 6.357 9.290 23.03 10 1,951 2,230 2,322 products have a working pressure rating 150 161.5 13.8 34.27 '10 885 1,012 1,053 of 300 psi maximum and also meet the 8" 8.249 16.490 40.15 7 2,424 2,770 2,885 stringent requirement for the following 200 209.5 24.5 59.75 7 1,100 1,256 1,309 tests: •Welded Outlets •Hydrostatic Pressure •Side Wall Rupture Listed Approved Listed •Vibration Test t CO Flow Control n Q^I 16100 S. Lathrop• Harvey, IL 60426 Customer Service: y / _•' allied 11350 Norcom Rd.•Philadelphia, PA 19154 (800)882-5543 TUBE&CONDUIT 2525 N.27 th Ave.•Phoenix,AZ 85009 Fax 708-339-1806 S5 - 3 Design Requirements The Globe grooved butterfly valve should be connected to the piping system with approved couplings or flange adapters. Flow may be from either direction, and the valve may be positioned in any direction. Globe butterfly valves have been designed with a slow close hand wheel operator, which effectively minimizes water hammer. These valves feature minimum flow restriction and pressure loss when in the fully open position. Installation When the valves are received from the manufacturer they-should be handled carefully to avoid breakage and damage to the seating area. Before installation of the valve,clean piping,flange and coupling.When the valve closes hard, it is usually due to debris lodged in the sealing area. Often this may be corrected by backing off the hand wheel and closing again. The valve should never be forced to seat by applying a wrench to the hand wheel as this may distort the valve components or score the sealing surface. The use of excessive force to open or close the valve violates all warranties whether express or implied. The inlet and outlet pipe adjacent to the valve should be properly supported to prevent excessive stress on the valve body.The valves should not be used to force a pipeline into position as this may result in distortion of the valve body. Conduit and electrical connections to the optional tamper switch must be in accordance with National Electrical Code (NFPA 72) and requirements of the local authority having jurisdiction. Care and Maintenance Globe butterfly valves require no regular maintenance,however,it is advisable to inspect and verify proper operation of the unit annually or in accordance with the authority having jurisdiction. The inspection should include a visual check for leakage at the valve pipe connection and body to operator connection. Inspection and maintenance should be performed by a qualified inspection service. Switch Installation Globe butterfly valves are provided with internal supervisory position switches.The tamper switch operates by a cam connected to the valve stem.The switch will change position within two (2)full turns of the hand wheel from the fully open position. Switch #1 S-1 -OPEN(YELLOW) For connection to the supervisory circuit. COMMON(WHITE) CLOSED(RED) Normally closed: 2 Red FIRE A ARM END OF LINE CONTROL PANEL RESISTOR OR SUPERVISORY CIRCUIT NE%T DEVICE Normally open: 2 Yellow (GREEN) ACTUATOR CASE GROUND Common: 2 White $WItCh #2 O OPEN(BLUE) Auxiliary switch connected per authority. VOLTAGE COMMON(BLACK) CLOSED(ORANGE) AD%. DEVIGE SOURCE (BELL OR HORN) Normally closed: 1 Orange NOTES 1.RATED:5A-1/6HP-125/250V Normally open: 1 Blue Shown with valve in closed position Common: 1 Black Ground Lead: 1 Green AUGUST2006 Pagel BULLETIN BUTTERFLY REV#2 XA R, ® GLR30OG IO � FIRE SPRINKLER Grooved Butterfly Valves LOB CORPORATION Grooved End, Sizes : 2112",3►►,4►►, 6►►and8►► Specifications Working Pressure : 300 PSI (21.4 Bars) Max. Test Pressure : 600 PSI (42.8 Bars) Max. Working Temp : 250°F (120°C) Factory installed UL Listed Double Tamper Switch For Indoor and Outdoor Use. Materials of Primary Components Body: ASTM A-536 Nylon-11 Coated Disc : ASTM A-536 EPDM Encapsulated < Upper and Lower Stems : AISI 420-SS ' Worm Gear Shaft : AISI 410-SS Housing : ASTM A-536 Hand Wheel : ASTM A-536 Flag Indicator : ASTM A-536 Sheer Pin : ASTM A-510 Segment Gear : ASTM B-148 or B-584 Housing Gasket : EPDM Grade "E" O-Rings (All) : EPDM Grade "E" Approvals NYC - DOB MEA Approved 155-06-E UL, ULC Listed FM Approved r A E B l O 5.00 �. ►�� D 4.37 (127.0) ( l 1 1 .0) DIMENSION UNIT:IN(mm) SIZE A B C D E Part No. 21/2' 5.31 (135) 5.04(128) 4.13(105) 3.30(85) 3.80(96.4) 311785-G 3" 5.59(142) 5.04(128) 4.41 (112) 3.60(92) 3.80(96.4) 311790-G 4" 6.89(175) 5.04(128) 5.71 (145) 4.30(108) 4.54(115.4) 311795-G 6" 8.23(209) 8.66(220) 7.05(179) 5.71 (145) 5.21 (132.4) 311865-G 8" 9.21 (234) 8.66(220) 8.03(204) 6.70(170) 5.80(147.4) 311815-G AUGUST2006 Page4 BULLETIN BUTTERFLY REV#2 GROOVED END Flow Characteristics 1.2 Y i 21/2' 6n 8- 1.0 0.8 L,a W N � a 0.6 - —� W zz 04 0.2 ` OF 0.0 100 1,000 10,000 FLOW RATE IN GALLONS PER MINUTE(GPM) WAFER AND GROOVED END Friction Loss Friction Loss in Friction Loss in Valve Size in. Equiv. Feet of Valve Size in. Equiv. Feet of Valve Model (mm) Pipe Valve Model (mm) Pipe DW(Wafer) 2'/Z(65) 4.8 DG(Grooved) 2%2(65) 6.9 3(76.2) 3.5 3(76.2) 4.1 4(100) 2.4 4(100) 3 6(150) 5.1 6(150) 5.5 8(200) 5.4 8(200) 5.4 GROOVED END Flow coefficient : Cv DN (mm) SIZE(in) Disk Open Angle 300 400 500 600 700 800 900 65 2'/z" 12 27.4 53.1 96 138 156 163 80 3" 18.9 39.4 78.9 144 210 243 249 100 4" 30 65.1 129 226 377 488 514 150 6" 84 184 369 634 964 1196 1286 200 8" 165 339 677 1230 2002 2850 3129 WAFER TYPE Flow coefficient : Cv at full open DN (mm) 65 80 100 150 200 Size (in.) 2'/z' 3" 4" 6" 8" Cv 222 389 1000 1998 4619 Cv= flow(9pm) = Q pressure loss(psi) %r4 P AUGUST2006 Page6 BULLETIN BUITERFLYREV#2 SWING CHECK VALVE STANDARD & "SHOTGUN" MODEL RCV FIRE SPRINKLER CORPORATION GROOVE/GROOVE DESCRIPTION AND OPERATION 2", 2 Y2'vrt 3 rr 4" & 61`1 SIZES Globe Model RCV Swing Check Valves feature a swing type clapper designed for use in fire sprinkler or other types of water piping systems that incorporate grooved connecting pipe ends. They are effectively used when it is necessary to permit water flow in one direction only, preventing flow in the reverse direction (non- return). Because the RCV incorporates a spring-loaded clapper assembly, it may be installed in either the vertical or horizontal position. Most commonly, it is used with various configurations of fire department connections for fire sprinkler systems, by-pass connections,gravity pressure tank and, pump discharge in connec- tions from public water supplies to automatic sprinkler systems,etc. As an alternative to using an alarm check valve with a wet sprinkler system, an RCV Swing Check Valve may be used in a "Shotgun" arrangement whereby the valve is trimmed in a similar manner but utilizes an electric water flow switch and alarm bell instead of a water motor gong for fire notification. The body of the Globe RCV Swing Check Valve is constructed MODEL RCV of high tensile strength cast iron having considerable ductility to SWING CHECK VALVE reduce damage in field handling. It meets the ASTM A126 Class B rating. The RCV clapper assembly is made of stainless steel and has an E.P.D.M. rubber facing. The RCV incorporates a special stainless steel spring assembly which allows its use in the down- ward flow direction. It effectively provides a leak tight seal against back pressures greater than one (1) psi. PHYSICAL DIMENSIONS APPROVALS • cULus Listed "H' ® FM Approved OPTIONAL FOR RISER O . NYC - DOB MEA 305-05-E INSTALLATION TECHNICAL DATA • Water Working Pressure Rating -300 psi (20.7 Bars). ® Factory tested hydrostatically to 600 psi (41.4 Bars). E O Equivalent feet of pipe: 2"Valve= 7.2 feet, 2 1/2" 1� Valve=7.2 feet, 3"Valve=7.2 feet, 4"Valve-9.9 feet, 6"Valve= 16.1 feet. %-14NPT J. WEIGHT SIZE A C E F G H I J K L (Ibs.) no trim 2" 1" 4" 3 1/2" 4 1/2" 6 1/2" 1/4" 1 1/2" 2 1bf 2 1/2" 4 3/4" 4.5 2 1/2" 1 1/4" 4 1/2" 4" 5" 7" 1/4" 1 1/2" 2 1/2" 2 3/4" 5 1/2" 8 3" 1 1/4" 5" 4 1/2" 6" 7 3/4" 1/4" 2" 3" 3 3/4" 6 3/4" 12 4" 2" 6 1/4" 4" 6 1/2" 8 1/2" 1/4" 2 I/2" 3 I/2" 4 I/4" 7 I/2" 17.5 6" 2" 8" 5" 8" 10 1/2" 1/4" 3 I/4" 4 I/4" 5 I/2" 10" 40.5 4077AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-8464583 • FAX989-846-9231 OCTOBER2005 .-10 BULLETIN RCV REV.#1 SWING CHECK VALVE - 2", 2 %", 3 Ff 4" & 6'r MODEL RCV - STANDARD & "SHOTGUN" GROOVE/GROOVE 3 ITEM DESCRIPTION MATERIAL 2"P/N 2%i'P/N 3"P/N 4"P/N 6"P/N I Hinge Pin Stainless Steel 321521 321528 321535 321541 321549 \'` O 12 2 Torsion Spring Stainless Steel 321523 321531 321531 321545 321554 0 2 3 Machined Body Cast Iron 321501 321503 321505 321507 321509 8 ` 10 4 1/2"NPT Plug Cast Iron 311003 311003 311003 311003 311003 5 Seat Ring Brass 321516 321530 321537 321543 321551 1 6 Locknut Stainless Steel 321556 321556 321556 321556 321556 9 op 7 Nameplate Aluminum 321558 321558 321558 321558 321558 5 8 Clapper Stainless Steel 321515 321 S27 321534 321540 321548 4 9 Clapper Facing Disc EPDM 321516 321529 321536 321542 321550 11 e 10 Sealing Washer Hard Fiber 321518 321518 321518 321518 321518 CROSS SECTION I I Disc Retainer Stainless Steel 321517 321517 321517 321544 321544 12 Hex Head Bolt Stainless Steel 1 321519 1 321519 1 321555 321555 321559 "SHOTGUN TRIM ARRANGEMENT 2 SIZE A B C 4 2" 10" 5 8 3/4" 2 1/4" 7 3 J2 I/2" II" 9 I/4" 2 I/4" 6 1 3" 12" 9 I/2" 2 I/2" 4 4" 13 1/2" 10" 3 1/4" 8 O g 6" 14 1/4" 10 3/4" 4" 6 TOP VIEW FRONT VIEW ITEM DESCRIPTION 2" 2%" 3" 4" 6" QTY. I RCV 321526 321533 321539 321547 321557 1 2 Angle Valve 311614(1") 311615(1 1/4") 311615(1 1/4") 311617(2") 311617(2") 1 3 Close Nipple 310500(1") 310600(1 1/4") 310600(1 1/4") 310800(2") 310800(2") 1 4 1/4"Water Gauge 300119 300119 300119 300119 300119 2 5 1/4"3 Way Valve 311683 311683 311683 311683 311683 2 6 1/4"Plug 311001 311001 311001 311001 311001 2 7 1/4"Nipple 311 101 (1 1/2") 31 1 102(2") 310102(2") 310103(21/2") 310103(2 1/2") 1 8 1/4"x 5 1/2"Nipple 310109 310109 310109 310109 310109 1 ORDERING INFORMATION GLOBE° PRODUCT WARRANTY Globe agrees to repair or replace any of its own SPECIFY manufactured products found to be defective in material •Quantity • Model Number or workmanship for a period of one year from date of •Standard or Shotgun style. shipment. For specific details of our warranty please refer to Price List Terms and Conditions of Sale(Our Price List). GLO 4077AIRPARK DRIVE,STANDISH,MICHIGAN 48658 - -ABA; FIRE SPRINKLER CORPORATION 989-846-4583 FAX989-846-9231 OCTOBER2005 PRINTED U.S.A. BULLETIN RCV REV.#1 tL�CO Fire & Building Products Technical Services:Tel:(800)381-9312/Fax:(800)791-5500 Model DPV-1 Dry Pipe Valve, External Resetting 2-112 thru 61nch (DN65 thru DN150) 250 psi (17,2 bar) General Description �- The Tyco@ Model DPV-1 Dry Pipe Valves are differential valves used to 16 automatically control the flow of water - into dry pipe fire protection sprinkler t_ systems upon operation of one or more automatic sprinklers.The DPV-1 t also provides for actuation of fire alarms upon system operation. The Model DPV-1 features are as follows: • External reset. • 250 psi (17,2 bar) pressure rating. • Unique offset single clapper design enabling a simple compact valve to minimize installation labor. , • Ductile iron construction to ensure a lightweight valve to minimize ship- ping cost. • A variety of inlet and outlet connec- Available End Connections and Sizes tions. Nominal Valve Size • Compact, semi-preassembled Or End Connection 2-1/2 Inch 3 Inch 4 Inch 6 Inch fully assembled,and easy to operate (DN65) (DN80) (DN100) (DN150) valve trim. • Simple reset procedure through the Flange x Flange N/A N/A • • elimination of priming water. Dry pipe sprinkler systems are used in Flange x Groove N/A N/A • • unheated warehouses, parking ga- rages, store windows, attic spaces, Groove x Groove • • • • loading docks, and other areas ex- posed to freezing temperatures,where • Available water filled pipe cannot be utilized. N/A Not Available When set for service, the dry pipe sprinkler system is pressurized with air (or nitrogen). The loss of pressure responsible for maintain- WARNING The owner is res through an operated automatic sprin- P kler in response to heat from a fire The Model DPV-1 Dry Pipe Valves de- ing their fire protection system and de- permits the DPV-1 Dry Pipe Valve to scribed herein must be installed and vices in proper operating condition. open and allow a flow of water into the maintained in compliance with this The installing contractor or manufac- sprinkler system piping. Table B es- document,as well as with the applica- turer should be contacted with any tablishes the minimum required sys- ble standards of the National Fire Pro- questions. tem air pressure that includes a safety tection Association, in addition to the factor to help prevent false operations standards of any other authorities hav- that might occur due to water supply ing jurisdiction. Failure to do so may fluctuations. impair the performance of these de- vices. Page 7 of 20 AUGUST, 2007 TFP1020 Page 2 of iO TFP1020 NO.DESCRIPTION QTY. REF. I Valve Body ....... 1 NR 2 Air and Water Seat ............ I NR 3 Handhole Cover ... 1 NR 4 Handhole Cover Gasket .......... 1 See(b) 0-11 5 1/2-13 UNC x 1"Hex Head Cap Screw: 2-1/2&3 Inch 12 Valves...........5 CH 6 4 Inch Valve ......6 CH 13 6 Clapper.......... 1 See(a) 7 7 Clapper Facing.... 1 See(a)or(b) CLAPPER RESET 8 Clapper Facing ASSEMBLY 14 PLUNGER Retaining Plate.... I See(a) 8 PARTS 9 2-1/2 and 3 Inch Valves: 1/4"x 3/8"Long _'15,18 #10-32 Shoulder Screw ...........5 See(a) 16 4 Inch Valve: 1/4-20 UNC x 1/2" Socket Head Cap 17 Screw ...........7 See(a) 10 Clapper Hinge Pin ............. I See(a) 11 Reset Knob ...... I See(c) 12 Reset Spring ..... 1 See(c) 13 Reset Bushing .... 1 See(c) 14 Reset Bushing 0-Ring........... 1 See(b)or(c) 15 Reset Plunger O-Ring .......... 1 See(b)or(c) 16 Reset Plunger..... I See(c) 2 17 Reset Latch Subassembly ..... 1 See(c) 18 Dow Corning FS3452 Flourosilicone Grease,1.5 g ..... 1 See(b)or(c) 4 NR:Not Replaceable CH:Common Hardware REPLACEMENT PARTS 0 NO. DESCRIPTION P/N (a) Clapper Assembly 0 0 Includes Items 6-10: 2-1/2&3 Inch Valves .. 92-309-2-203 4 Inch Valve ......... 92-309-2-403 10 Q (b) Repair Parts Kit Includes Items Q0- 5 4,7,14,15,&18: 2-1/2&3 Inch Valves.. 92-309-1-204 4 Inch Valve ......... 92-309-1-404 (c) Reset Plunger Parts Kit Includes Items: [11 through 18 ........ 92-309-1-405 FIGURE 1 Part 1 of 2 MODEL DPV-I DRY PIPE VALVES 2-112,3,and 4 INCH(DN65,DN80,and DN100) —ASSEMBLY— TFP1020 Page 5 of 20 FLOW RATE IN LITRES PER MINUTE(LPM) (1 GPM=3.785 LPM) 500 700 1000 2000 3000 5000 7000 10000 9.0 0,60 8.0 7.0 0,50 JF 6.0 0,40 IF 5. If 0,30 4.0 JF 1=4 3.0 0,20 Co x z 2.0Uj Q2� ¢ U� 7 Q O� 0,10 C° z aw goy �o� 0,09 a o �� p= 0,08 xo M Z) 1.0 2V U� �y� 0,07 �m 0- ti = _ Mo Z 0.9 ti d 0,06 w o d 0.8 U ¢W 0 0.7 0,05EC ¢a 0.6 0,04 0 Co O Z w 0.5 Q a z 0.4 O Z 0.3 0,02 0.2 0,01 0.1 100 200 300 400 500 700 1000 2000 3000 FLOW RATE IN GALLONS PER MINUTE(GPM) The approximate friction losses,based on the Hazen and Williams formula and expressed in equivalent length of Schedule 40 pipe with C=100 are as follows: 2.2 feet for the 2-1/2 inch valve at a typical flow rate of 250 GPM 4.9 feet for the 3 inch valve at a typical flow rate of 350 GPM 8.9 feet for the 4 inch valve at at typical flow rate of 600 GPM 22 feet for the 6 inch valve at a typical flow rate of 1500 GPM FIGURE 2 MODEL DPV-1 DRY PIPE VALVES —NOMINAL PRESSURE LOSS VERSUS FLOW— Page 6 of 20 TFP1020 This action permits water flow into the Operating system piping and subsequently to be Maximum System Air discharged from any open sprinklers. Water Supply Pressure Principles Also,with the Clapper Assembly open, Pressure, Range, the intermediate chamber is pressur- psi psi The Model DPV-1 Dry Pipe Valve is a ized and water flows through the alarm differential type valve that utilizes a port(Ref. Figure 36) at the rear of the 20 10 substantially lower system(air or nitro- DPV-1 Valve to actuate system water gen) pressure than the supply (water) flow alarms. The flow from the alarm 60 15-23 pressure, to maintain the set position port is also sufficient to close the oth- shown in Figure 3A. The differential erwise normally open Automatic Drain 80 20-28 nature of the DPV-1 is based on the Valve in the valve trim. area difference between the air seat After a valve actuation and upon sub 100 25-33 and the water seat in combination with P the ratio of the radial difference from sequent closing of a system main con- 120 30-38 the Hinge Pin to the center of the trol valve to stop water flow,the Clap- Water Seat and the Hinge Pin to the per Assembly will latch open as shown 145 35-43 center of the Air Seat. The difference in Figure 3D. Latching open of the is such that 1 psi (0,07 bar) of system DPV-1 will permit complete draining of 165 40-48 air pressure can hold approximately the system(including any loose scale) 5.5 psi(0,38 bar)of water supply pres- through the main drain port. 185 45-53 sure. During the valve resetting procedure 205 50-58 Table B establishes the minimum re- and after the system is completely quired system air pressure that in- drained; the external reset knob can 225 55-63 cludes a safety factor to help prevent be easily depressed to externally un- false operations that occur due to latch the Clapper Assembly as shown 250 60-68 water supply fluctuations. in Figure 3E. As such, the Clapper Assembly is returned to its normal set TABLE B The Intermediate Chamber, of the position to facilitate setting of the dry SYSTEM AIR PRESSURE DPV-1 is formed by the area between pipe sprinkler system, without having REQUIREMENTS the Air Seat and Water Seat as shown to remove the Handhole Cover. in Figure 313.The Intermediate Cham- ber normally remains at atmospheric pressure through the Alarm Port con- nection and the valve trim to the nor- mally open Automatic Drain Valve (Fig.4,5, or 6). Having the Intermedi- ate Chamber, Figure 313, open to at- mosphere is critical to the DPV-1 Valve remaining set,otherwise the full resulting pressure of the system air pressure on top of the Clapper Assem- bly cannot be realized. For example and assuming a water supply pressure of 100 psi(6,9 bar), if the system air pressure is 25 psi (1,7 bar) and there was 15 psi (1,0 bar) pressure trapped in the Intermediate Chamber, the resulting pressure across the top of the Clapper would only be 10 psi (0,7 bar).This pressure would be insufficient to hold the Clap- per Assembly closed against a water supply pressure of 100 psi (6,9 bar). It is for this reason that the plunger of the Automatic Drain Valve must be de- pressed during several of the resetting steps, as well as during inspections, making certain that the Automatic Drain Valve is open. When one or more automatic sprin- klers operate in response to a fire, air pressure within the system piping is relieved through the open sprinklers. When the air pressure is sufficiently reduced, the water pressure over- comes the differential holding the Clapper Assembly closed and the Clapper Assembly swings clear of the water seat, as shown in Figure 3C, TFP1020 Page 9 of 20 20 32 16 NOTES: 1 1. SEE FIGURE 3 FOR VALVE 19 PORT IDENTIFICATION. 20 5 6 9 32 23 2. ROUTE 1/4"TUBING,ITEM 14, 34 32 32 TO DRIP FUNNEL,ITEM 12. 9 32 30 15 33 31 24 16 4 3 25 ® 27 22 41 40 31 LOCATION 32 23 8 FOR OPTIONAL 36 18 ELECTRICALLY 10 Og 5 SUPERVISED 32 0 N.O.ALARM 31 CONTROL 20 11 12 0� VALVE 2-1/2 INCH(DN65) 26 (BVS-1/2") or 3 INCH(DN80) 39 p2 MODEL DPV-1 31 13 6 35 17 Ok 28 DRY PIPE VALVE 14 (GREEN TINT) 37 NO.DESCRIPTION CITY. P/N 7 32 2 21 27 1/2"x 1/2"x 3/4" 26 38 Reducing Tee .....1 CH 28 1"x 1"x 1/2" NO.DESCRIPTION CITY. P/N 30 15 Reducing Tee .....1 CH 29 Not Used 1 250 psi11750 kPa 3 30 1/4"x 3"Nipple....2 CH Air Pressure 31 1/2"x Close Gauge...........1 92-343-1-012 NO.DESCRIPTION CITY. P/N Nipple ...........4 CH 2 300 psi/2000 kPa 32 1/2"x 1-1/2" Water Pressure 13 3132"Vent Nipple ...........8 CH Gauge...........1 92-343-1-005 Fitting ...........1 92-032-1-002 33 1/2"x 2"Nipple....1 CH 3 1/4"Gauge Test 14 1/4"Tube, 34 1/2"x 4-1/2" Valve............2 46-005-1-002 18"Long .........1 CH Nipple ...........1 CH 4 Model AD-1 15 1/4"Plug.........2 CH 35 1/2"x 6"Nipple....1 CH Automatic 16 1/2"Plug.........2 CH 36 3/4"x Close Drain Valve.......1 52-793-2-004 17 1"Plug ..........1 CH Nipple...........1 CH 5 1/4"Pressure 18 1/2"Union........1 CH 37 3/4"x 1-1/2" Relief Valve.......1 92-343-1-020 19 1/2"x 1/4"Reducing Nipple ...........1 CH 6 1/2"Ball Valve ....2 46-050-1-004 Bushing .........1 CH 38 3/4"x 2-1/2" 7 3/4"Angle Valve ...1 46-048-1-005 20 1/2"90'Elbow ....3 CH Nipple...........1 CH 8 1-1/4"Angle Valve .1 46-048-1-007 21 3/4"901 Elbow ....1 CH 39 1"x Close Nipple ..1 CH 9 112"Swing 22 1-1/4"90°Elbow...1 CH 40 1-1/4"x Close Check Valve ......2 46-049-1-004 23 1/2"Cross........2 CH Nipple...........1 CH 10 Drip Funnel 24 1/2"x 1/2"x 1/4" 41 1-1/4"x 4"Nipple ..1 CH Connector........1 92-211-1-005 Reducing Tee .....1 CH 11 Drip Funnel 25 1/2"Tee .........1 CH All Fittings and Nipples Bracket..........1 92-211-1-003 26 1/2"x 1/4"x 1/2" are Galvanized 12 Drip Funnel.......1 92-343-1-007 Reducing Tee .....2 CH CH:Common Hardware FIGURE 4—Part 1 of 2 2-112 and 3 INCH(DN65 and DN80)MODEL DPV-1 DRY PIPE VALVES —EXPLODED VIEW OF VALVE TRIM— Page 16 of 20 TFP1020 that it will not cause accidental dam- Installation age to property or danger to persons. valve Setting NOTES Step 7.Unused pressure alarm switch procedure Proper operation of the Model DPV-1 and/or water motor alarm connections Dry Pipe Valve depends upon its trim must be plugged. Steps 1 through 11 are to be per- being installed in accordance with the Step 8.The Pressure Relief Valve pro- formed when initially setting the Model instructions given in this Technical vided with the Valve Trim is factory set DPV-1 Dry Pipe Valve;after an opera- Data Sheet. Failure to follow the ap- to relieve at a pressure of approxi- tional test of the fire protection system; propriate trim diagram may prevent mately 45 psi(3,1 bar),which can typi- or,after system operation due to a fire. the DPV-1 Valve from functioning cally be used for a maximum normal properly, as well as void listings, ap- system air pressure of 40 psi(2,8 bar). NOTES provals, and the manufacturer's war- The Pressure Relief Valve may be re- If the DPV-1 is equipped with a Dry ranties. set to a lower or higher pressure;how- Pipe Valve Accelerator, refer to its re- Failure to latch open the Clapper As- ever,it must be be reset to relieve at a setting instructions before resetting sembly prior to a system hydrostatic pressure which is in accordance with the DPV-1. Refer to TFP1100 for the test may result in damage to the Clap- the requirements of the Authority Hav- QRS or TFP1112 for the ACC-1. per Assembly. ing Jurisdiction. Based on the instructions provided,re- The DPV-1 Valve must be installed in To reset the Pressure Relief Valve, set the Accelerator at the appropriate a readily visible and accessible loca- first loosen the jam nut and then adjust time during the resetting of the DPV-1. tion. the cap accordingly—clockwise for a Step 1.Close the Main Control Valve, higher pressure setting or counter- and close the Air Supply Control Valve The DPV-1 Valve and associated trim clockwise for a lower pressure setting. (Fig. 4, 5, or 6). If the DPV-1 is must be maintained at minimum tem- After verifying the desired pressure equipped with a Dry Pipe Valve Accel- perature of 40 F14 C. setting,tighten the jam nut. erator,remove the Dry Pipe Valve Ac- Heat tracing of the DPV-1 Valve or its Step 9. Installation of an Air Mainte- celerator from service in accordance associated trim is not permitted. Heat nance Device, as described in the with its Technical,Data Sheet(Refer to tracing can result in the formation of Technical Data Section, is recom- TFP1100 for the°QRS or TFP1112 for hardened mineral deposits that are ca- mended. the ACC-1). pable of preventing proper operation. Step 10.An Inspector's Test Connec- Step 2. Open the Main Drain Valve The Model DPV-1 Dry Pipe Valve is to tion as required By NFPA 13 must be (Fig.4,5,or 6)and all auxiliary drains be installed in accordance with the fol- provided on the system piping at the in the system.Close the auxiliary drain lowing criteria: most remote location from the Model valves after water ceases to dis- Step 1. All nipples, fittings, and de- DPV-1 Valve. charge. Leave the Main Drain Valve vices must be clean and free of scale Step 11. Conduit and electrical con- open. and burrs before installation. Use pipe nections are to be made in accordance Step 3. Depress the plunger of the thread sealant sparingly on male pipe with the requirements of the authority Automatic Drain Valve(Fig.4,5, or 6) threads only. having jurisdiction and/or the National to verify that it is open and that the Step 2. The DPV-1 Valve must be Electric Code. DPV-1 Valve is completely drained. trimmed in accordance with Figures 4, Step 12. Before a system hydrostatic Step 4.Open the Optional Alarm Con- 5, or 6, as applicable. If the DPV-1 is test is performed in accordance with trol Valve (Fig. 4, 5, or 6), as applica- to be equipped with a Dry Pipe Valve NFPA 13 system acceptance test re- ble, if it was closed to silence local Accelerator, refer to the Technical quirements, the Clapper Assembly is alarms. Data Sheet TFP1100 for the Model to be manually latched open(Ref. Fig. Step 5. As necessary, replace all QRS Electronic Dry Pipe Valve Accel- 3D);the Automatic Drain Valve(Fig.4, sprinklers that have operated. Re- erator or TFP1112 for the Model ACC- 5, or 6) is to be temporarily replaced placement sprinklers must be of the 1 Mechanical Dry Pipe Valve Accel- with a 1/2 inch NPT plug,the 3/32 inch same type and temperature rating as erator. Vent Fitting (Item 13, Fig. 4; Item 15, those which have operated. Step 3. Care.must be taken to make Fig. 5; or Item 15, Fig. 6) is to be sure that check valves, strainers, temporarily replaced with a 1/4 inch NOTE globe valves,etc.are installed with the NPT plug, and the Handhole Cover In order to prevent the possibility of a flow arrows in the proper direction. Bolts are to be tightened using a cross- subsequent operation of an over- draw sequence. heated solder type sprinkler, any sol- Step 4. Drain tubing to the drip funnel der type sprinklers which were possi- must be installed with smooth bends bly exposed to a temperature greater that will not restrict flow. than their maximum rated ambient Step 5.The main drain and drip funnel must be replaced. drain may be interconnected provided Step 6.Push down on the Reset Knob a check valve is located at least 12 (Fig. 3E)to allow the Clapper Assem- inches(300 mm)below the drip funnel. bly to reseat. The Low Body Drain Valve (Fig. 4, 5, or 6) may be piped so as to discharge Step 7. Pressurize the system with air into the Drip Funnel or to a separate (or nitrogen) to 10 psi (0,7 bar), and drain. then individually open all auxiliary Step 6. Suitable provision must be drain valves in the system piping to made for disposal of drain water. drain any remaining water in trapped sections. Close each drain valve as Drainage water must be directed such soon as water ceases to discharge. UNITED BRASS WORKS, INC. ,�,,,A�wuA 714 S. Main St., Randleman, NC 27317 f509001 Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com REGISTERED DDARANY Model 125SUL Globe Valve Soft Disc -- c �U L SUL Listed for Fire Sprinkler Service at 250 WOG 200 WOG @ 180 ' Max 100% Pressure Tested Threaded Ends • Integral Seat Rising Stem Swivel Disc Holder B �O 3 MATERIAL LIST 4 NO. DESCRIPTION MATERIAL ` s 1 Hex Nut Steel 2 Hand Wheel Aluminum i 3 Packing Nut Brass s 4 Packing Graphite Non-Asb. 5 Bonnet('/,." —I") Brass Bonnet(1'/4"—2") Bronze a 6 Stem&Disc Assm. Brass i 7 Disc Buna N A 8 Body Bronze Size 1/21 g/49 1" 1 1/4» 1 Y2" T5 A 2.22 2.47 2.97 3.56 4.06 4.69 B 2.03 2.38 2.75 3.00 3.72 3.72 C(closed) 3.38 3.50 4.25 4.75 5.50 5.50 Ship Wt.(lbs.) 0.69 0:94 1.76 2.50 3.26 5.32 Qty.Unit Pack 12 6 6 4 2 2 Qty.Per Case 72 60 36 24 1 12 12 Id si,,,T, INS-P-MOTO-A" I Remote Inspector's Test for Single Story and Other Applications Systems Requiring Pressure Relief Valve > -lit C&S � 3: • The AGF Manufacturing Inc. Model 3011 INSPECTOR'sTEST°family of valves are designed to perform the remote inspector's test function on single story and other applications with the benefit of locating the orifice indoors. • The Model 3011 INSPECTOR'sTEST° is available in four different models: - Model 3011BV ball valve only - Model 3011SG ball valve with sight glass - Model 3011A ball valve with Model 7000 Pressure Relief Valve and drainage piping - Model 3011ASG ball valve with sight glass, Model 7000 Pressure Relief Valve, and drainage piping • Available with test orifice sizes of 3/8" (2.8K), 7/is" (4.2K), 1/2" (5.6K), 17/32" (8.OK), and 5/s" (11.2K, ELO). • The Models 3011A and 3011ASG have the added feature of a Model 7000 Pressure Relief Valve with drainage piping designed to relieve excess system pressure caused by surges or temperature changes as well as solve the difficult problem of providing the relief valve with a drainage piping outlet. • The Models 3011A and 3011ASG comply with the requirements of NFPA-13 for the installation of a pressure relief valve on all gridded systems and downstream of all pressure reducing valves. • The included UUFM Model 7000 Pressure Relief Valve features a flushing handle and is rated at 175 PSI. Other pressure settings are also available. (see note below) • To expedite system testing, the unit is shipped semi-assembled with relief valve and bypass drain ports plugged. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve.Standard relief valves are required to OPEN in a range of pressure between 90%and 105%of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for main- tenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. ReftabfflyVbmaff tCode I NSP ECTORSTEST is a registered trademark of AGF Manufacturing Inc. CS3011 3/08 Model 13 cousINSPECTOPIsTEST AF ® Model 3011 300„ ,, , Pressure APPR9VED Relief Valve Factory Rated at 175 PSI with other settings . - MODEL 3011A MODEL 3011ASG DIMENSIONS —B— Orifice Size Available:3/8",7/16", 1/2","/32", ELO(5/8") B~ i Model A B C D 1 o A 0 lil 3011A 1 31/16 411/16 77/8" 47/8" +I (75 mm) (118 mm) (200 mm) (124 mm) c 3011 ASG 31/16" 411/16" 95/16" 61/4" ® (75 mm) (118 mm) (237 mm) (159 mm) ° 3011 BV 31/16" 411/1 6" ID / V5 mm) (118 mm) 1 3011 SG 31/6" 411/16" 63/16" 31/8" © p5 mm) (118 mm) (157 mm) (79 mm) L -,L MODEL 3011 BV MODEL 3011 SG MATERIALS APPROVALS I— B—I Handle:Steel UL and ULC Listed: I. s I Stem: Rod Brass [EX4019(N)&EX4533(N)] Ball:C.P. Bronze FM Approved llil Body: Bronze NYC-BSA No.720-87-SM n O 1 c Valve Seat:Virgin Teflon°t Relief Valve: Bronze® �1 ° Bypass Fittings: Brass �1 1 Bypass Tubing: Nylobraid Sight Glass: Bronze&Glass MADE IN U.S.A. FROM THE NFPA 13 2007 EDITION Models 3011 BV,3011 SG,3011A,&3011ASG,depending on the variant chosen,provide some or all of the requirements listed below: Chapter 8.16.2.4.1' Provisions shall be made to properly drain all parts of the system. Chapter 8.16.2.4.2 Drain connections, Interior sectional or floor control valve(s)-shall be provided with a drain connection &8.16.2.4.3 having a minimum size as shown in Table 8.16.2.4.2. Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling the flow of the drain. Chapter 8.16.2.4.6 The test connection shall be permitted to be used as main drain connection. Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into a drain capable of accepting full flow... using an approved sight test connection containing a smooth bore corrosion-resistant orifice giving a flow equivalent to one sprinkler...(M3011SG and M3011ASG only) Chapter 8.17.4.2.2 The test connection valve shall be readily accessible Chapter 8.17.4.2.4 shall be permitted to be installed in any location ...downstream of the waterflow alarm. Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure,whichever is greater. Chapter 8.16.1.2.3` A relief valve of not less than 1/2" in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 psi. Chapter A8.16.1.2.3 -consideration should be given to piping the discharge from the(pressure relief)valve Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion- resistant orifice,to provide a flow equivalent to one sprinkler... Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less than 1", at least one of which shall be brass. USA Patent # 4971109 . !Other Patents Pending AGF Manufacturing Inc. Job Name: 100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 Architect: ® Fax:610-240-4906 Engineer: www.testandrain.com Contractor: UNITED BRASS WORKS,, INC. R 714 S. Main St., Randleman, NC 27317 Tel: 800-334-3035 Fax: 800-498-4696 www.ubw.com IS09001 REGISTERED COMPANY Model 126SUL Angle Valve Soft Disc cO L us UL Listed for Fire Sprinkler Service at 250 WOG 200 WOG @ 180 ' Max 100% Pressure Tested Threaded Ends Rising Stem • Integral Seat B I 7 ' 3 4 C MATERIAL LIST \ \ 5 NO. DESCRIPTION MATERIAL \ 1 Hex Nut Steel 2 Hand Wheel Aluminum • s 3 Packing Nut Brass i 4 Packing Graphite Non-Asbestos 5 Bonnet(%2" - 1") Brass A Bonnet(1 1/4"—2") Bronze i 6 Stem&Seat Assembly Brass 8 7 Disc Buna N 8 Body Bronze A Size ''/21 3/4" 1" 11/4" 11/2" 2" A 1.03 1.22 1.47 1.75 2.00 2.34 B 2.03 2.38 2.75 3.00 3.72 3.72 C(closed) 3.13 3.25 4.38 4.50 5.25 5.63 Ship Wt.(lbs.) 0.69 0.94 1.76 2.50 3.26 5.32 Qty.Unit Pack 12 6 6 4 2 2 Qty.Per Case 72 60 36 24 12 12 SHURJOINT® FIRE PROTECTION PRODUCTS " www,shugoint.com Approvals Products for Fire Protection Piping Systems COUPLINGS AND FITTINGS Listing Pipe Rated Working Pressure Pipe Notes(See Coupling and Shurjoint Wall El psi Pub. Approval Size Range Fitting Notes on page Product❑Model No. Agency Inches Standard Light 13-14) IPS Carbon Steel Grooved Couplings #7705 Flexible Coupling 1"-8" 300 300 UL 8"(7705H) 450 450 1,2-1,14,15 10"-12" 175 175 C-01 1"-8" 300 300 o� FM 8"(7705H) 450 450 2-2,18,19 10"-12" 250 250 #7707 Flexible Coupling 3/4"-1 1/4'"' 500 500 2"-8" 500 450 UL1,3-1,14,17 10"-16" 300 18"-24" 250 - C-02 1 1/2"-10" 500 500 FM 12" 300 300 3-2,18,19 14"-22" 175 175 24" 250 250 #7771 Rigid Coupling 2"-8" 300 300 UL 10"-12" 175 175 1,5-1, 14"-20" --- 300 22"-24" --- 250 11/2" 500 500 C-05 2"-S" 300 500 FM 10" 200 200 5-2, 12" 300 300 14"-24" 175 175 #Z07 Angle Pad Coupling 1 1/4"-4" 500 500 UL 5"-8" 400 400 1 81 10" 350 350 12" - i C-06 $ 11/4"-4" 500 500 FM 5"-8" 400 400 8 2, 10" 350 350 12" 350 350 #K9 Lightweight Rigid Coupling UL, 1-1/4"-8" 300 300 ,. - 8"(K-9H) 350 300 G-01 FM 1-1/4"-8" 300 300 4 2, 8"(K-9H) 300 300 1/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED 9 Las Vegas,Nevada USA• www.shurjoint.com SHURJOINT® PRODUCTS wwm.shugoint.com #Z05 Angle Pad Rigid Coupling UL 1 1/4"-8" 350 350 1,7-1 G-03 � r FM 11/4"-8" 350 350 7-2 to , a #7706 Reducing Coupling UL 2"x 1-1/2" 300 300 1,10-1 C-07 FM 2"x1-1/2"_ 300 300 10-2 8"x6" #R20 Rigid Coupling UL 1-1/4"-6" 300 300 1,64 C-13 4D� FM 1-1/4"-6" 300 300 6-2, IPS Carbon Steel Grooved Flanges #7041 Flange-ANSI 125/150 UL 2"-8" 175 175 1,9-1 D-01 k4158-5110 FM 2"- 175 9-2 24' 175 #7043 Flange-ANSI 300 UL 2"-12" 300 300 1 o - D-03 FM 2"-12" 300 300 (b IPS Carbon Steel Hole Cut Products #7721 Mech.Tee,Threaded Outlet UL 2"x 1/2"- 300 300 1,13 8"x 4" f F-01 j FM 2"x 1/2" 300 300 -- 4"x8"x4" #7722 Mech.Tee,Grooved Outlet UL 3"x 1 1/2"- 300 300 1,13 8"x 4" F F-02 YY FM 3"x 1 1/2"- 300 300 8"x 4" 2/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products 9 1 800 746-GROOVED • Las Vegas,Nevada USA. www.shurjoint.com SHURJOINT® PRODUCTS mmshugant.com #C-7T Outlet Couplings UL 1-1/2"x 1/2"- 300 300 1 6"x 1-1/2" IN C-10 FM 1-1/2"x 1/2"- 300 300 - 1` 6 6"x 1-1/2" #C-7G Outlet Couplings UL 2"x 1" 300 300 1, 6"x 2" C-10 FM 2"x 1" 300 300 - i 6"x 2" #723 Saddle Let UL 1 1/4"x 1/2"- 300 300 1,12-1, 3"x 1" 11l F-03 / FM 1 1/4"x 1/2"- 300 300 12-2 3"x 1" IPS Carbon Steel Grooved Fittings #901 Short Radius 90'Elbow UL 2"-8" 300 300 1, G-02 FM 2"-8" 300 300 -- #903 Short Radius Tee UL 2"-8" 300 300 1, G-02 41 FM 2"-8" 300 300 -- #7110 90'Elbow UL 300 300 1 20"—24" 250 250 1"-8" 500 500 E-02 10"—12" 300 300 FM 14"-18",24" 175 175 ' 20" 250 250 3/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products e 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shudoint.com SHURJOINT® FIRE PROTECTION PRODUCTS www.shugoint.com #7111 45°Elbow UL 1-1/4"-18" 300 300 1, 20",24" 250 250 1-1/4"-8" 500 500 E-02 10"-12: 300 300 FM 14"-18",24" 175 175 20" 250 250 #7110DR Drain Elbow UL 2"-6" 300 300 1, G-05 if FM 2"-6" 300 300 -- #7110LR 1.51)Elbows UL 2"—8" 300 300 1 E-04 FM 2"—8" 300 300 #7112 22-1/2'Elbow UL 1-1/4" 500 500 1 1-1/2"-8" 300 300 E-04 it, FM 2"-8" 300 300 #7113 11-1/4'Elbow UL 2"—8" 300 300 1 E-02 FM 2"—8" 300 300 #7120 Tee UL 1-1/4"—18" 300 300 1 20"—24" 250 250 E-05 1-1/4"—8" 500 500 FM 10"—14" 300 300 16" 175 175 #7121 Reducing Tee UL 2"x 1-1/2"—12"x 300 300 1 10" E-06 FM 2"x 1-1/2"— 300 300 4/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shudoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA. www.shudoint.com SHURJOINT® PRODUCTS mmshugoint.com #7151 Eccentric Reducers UL 2 1/2"x 2"- 300 300 1, 8"x 6" E-07 16 FM 2 1/2"x 2" 300 300 S"x6" #7160 End Cap UL 1-1/4"-8" 300 300 1, E-08 FM 1-1/4"-12" 300 300 -- #7160H End Cap UL 10"-18" 300 300 1 20"—24" 250 250 E-08 40 FM 10"-12" 300 300 14"—24" 175 175 #7160T Transition Fittings 2"x V, UL 6"� 300 300 1, x 2" G-08 FM 2"x 1" 300 300 -- W1 x 2" #7170 Flange Adapter UL 21/2"-6" 175 175 1 D-04 FM 21/2"-6" 175 175 ro u ! -- r #7180 Universal Flange Adapters UL 2"-8" 300 300 -- D-08 0 FM 2"-8" 175 175 21 #55 Nipple Adapters UL 1 1/2"-2" 300 300 1 G-07 FM 1 1/2"-2" 300 300 6/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED 9 Las Vegas,Nevada USA• www.shurjoint.com TSHUMOINTO FIRE PROTECTION PRODUCTS www.shugoint.com #899 End All Fitting 1n 1 1/4"x 1/2"— 300 300 1, 2-1/2"x 1" G-06 i FM I 1/4"x 1/2"— 300 300 2-1/2"x 1" IPS Carbon Steel Outlet Fittings #71 Female Threaded Outlet Outlet x Header Fitting %11 x 1"x 1%"-8" 1'W x 2"—8" LIL I Y2"x 2"—8" 300 300 1, 2"x2"-8" 2%"x2'Y2"-8" 2'/2(76.1)"x2,Y2"-8" 3"x 3"--8" H-01 4"x 4"-8" %,1"x 1"-8" 1�/a",1�/2 x 2"-8" FM 2"x 2Y2-'-8" 300 300 2'/2"x3"—8 3"x 4"-8" 4"x 5"-8" 472C Cut Grooved Outlet 2"x 2"-8" Fittings 2-1/2"x2-1/2"-8" UL. 3"x 3"-8" 300 300 1, 4"x4"-8" fl 6"x6"x8" r' 8"x8"x10" x-oz 2-1/2"x3"-8 3"x 4"-8" FM 4"x 5"-8" 300 300 6"x 8" 8"x 10" #72R Roll Grooved Outlet 1-1/4"x 1-1/2"-8" Fittings 1-1/2"x 1-1/2"-8" UL 2 x 2"—8 300 300 1, 2-1/2"x2-1/2"-8 11 3"x 3"-8" 4"x 4"-8" H-03 1-1/4"x 1-1/2"-8" 1-1/2"x 2"-8" FM 2"x 2-1/2"-8" 300 300 2-1/2"x3"-8 3"x 4"-8" 4"x 5"-8" 7/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shudoint Piping Products • 1 800 746-GROOVED • Las Vegas,Nevada USA a www.shugoint.com PSISHURJOINTO FIRE PROTECTION PRODUCTS www.shudoint.com #74 Universal Threaded 1/2"x 1"-8" Outlet Fitting 3/4"x 1"-8" UL 1"x 1-1/4"—1-1/2" 300 300 1, 1"x 2"—2-1/2" 1"x 3"�8" H-04 1/2"x 1"-8" 3/4"x 1"-8" FM 1"x 1-1/4"—1-1/2" 300 300 1"x 2"-•2-1/2" 1"x 3"—8" Ductile Iron Fittings #811 90'Elbow UL 1/2"-2-1/2" 300 300 1 I-01 FM 1/2"-2-1/2" 300 300 #812 Reducing 90'Elbow 3/4"x 1/2"— UL 300 300 1 % I-01 3/4"x 1/2"— FM 300 300 -- #813 45'Elbow UL 1/2"—2-1/2" 300 300 1 it I-Ol FM 1/2"-2-1/2" 300 300 -- #814 Straight Tee UL 1/2"-2-1/2" 300 300 1 I-01 FM 1/2"-2-1/2" 300 300 -- #815 Reducing Tee UL 3/4"—2-1/2" 300 300 1 I-01 3/4"x3/4"xl/2" FM — 300 300 2-1/2"x2"x3/4" 8/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products 9 1 800 746-GROOVED • Las Vegas,Nevada USA• www.shurjoint.com TSHURJOINTO FIRE PROTECTION PRODUCTS mmshudoint.com #816 Reducing Coupling UL 3/4"xl/2"— lbaft2-1/2"x 2" 300 300 1 I-01 it FM 3/4"x 1/2"— 300 300 2"x 1-1/2" #817 Cross UL 1"-2" 300 300 1 I-01 1/2"-2" FM 1-1/4"x1"-2"xl" 300 300 -- #818 Straight Coupling UL 1/2"—2-1/2" 300 300 1 I-01 all, FM 1/2"-2-1/2" 300 3000 — #819 Plug UL 1/2"—2" 300 300 1 I-01 Is FM 1/2"—2" 300 300 - #820 Caps UL 1/2"—2-1/2" 300 300 1, I-01 ON FM 1/2"-2-1/2" 300 300 #825 Extension Pieces 1/2"x 1-1/2"— UL 3/4"x 2" 300 300 1, I-01 1/2"x 1-1/2"L— FM 3/4"x 2"L 300 300 9/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED 9 Las Vegas,Nevada USA. www.shudoint.com SHURJOINT® FIRE PROTECTION PRODUCTS wmv.shudoint.com Couplings and Fittings Notes 1. MEA Approved#322-06-E. 2. 2-1)UL Listed at 300 psi on the following sizes&pipe. i 1-I/4"-4"on XL,XL-II pipe,Dyna-Flow,Super-Flo pipe manufactured by Allied Tube&Conduit Corp,1-1/4"--6"on BS1387(IVi),British Standard Medium Steel pipe, 1-1/2"-3"on Eddy Flow pipe.,1-1/4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co, 1-1/4"--2"on Fire-Line Threadable pipe manufactured by Western International Forest Products Inc. UL Listed at 175 psi on the following sizes&pipes. 1-1/2"-3"on Eddy Flow Pipe manufactured by Bull Moose Tube Co, 1-1/4"—4"on Fire-Line Flow pipe manufactured by Western International Forest Products Inc., 1-1/4"-2"&3"on SPS pipe manufactured by Yieh Phui Enterprise Co.,Ltd. 1-1/4"—3"on Sch.5 pipe,10"on Sch.10(0.188 in)pipe,12"on Sch.30(0.330 in)pipe. 2-2)FM approved at 300 psi on the following sizes&pipes. 1-1/4"-6"on BS1387M or heavier grade pipe. 1"-4"on Dyna-Flow,Super-Flow(Allied)pipe 1"-2"&3"on Super 40,Super-XL(Allied)pipe. 1"-3"on XL-II(Allied)pipe 1"—2"on BLT,Dyna Thread(American Tube),Fire-Thread,Eddylite(Bull Moose),TL(Central),LS pipe, 1-1/2"--4"on Eddy Flow(Bull Moose Tube)pipe 1-1/4"&1-1/2"on Fire-Flow pipe FM approved at 175 psi on the following sizes&pipes. 1"-2"on WST(Weatland),Ultra Eddy(Bull Moose)pipe. 3. 3-1)UL Listed on the following sizes&pipe. At 500 psi in 2-1/2",5"-6"on BS1387(M),British Standard Medium Steel pipe pipe, At 450 psi in 1-1/2"&4"on Dyna-Flow pipe manufactured by Allied Tube&Conduit Corp, At 300 psi in size 10"&12"on sch.10(0.188 in)pipe,14"&16"on Sch.30(0.375 in)pipe, At 250 psi in 18"-24"on Sch.20(0.375 in)pipe. 3-2)FM approved on the following sizes&pipe. At 500 psi in 2-1/2",5"-6"on BS 1387 medium or heavy grade pipe 4. 4-1)UL Listed at 300 psi on the following sizes&pipe. 1-1/4"-8",3.00D,6.5013 on BS1387(IVi),British Standard Medium Steel pipe pipe, 1-1/4"&2"on Eddylite pipe manufactured by Bull Moose Tube Co, 1-1/4"—2"on Fine-Line Threadable pipe manufactured by Western International Forest Products Inc., 2"on Eddythread 40 pipe manufactured by Bull Moose Tube Co. UL Listed at 175 psi on the following sizes&pipes. 2"—3"on XL-Il,XL pipe manufactured by Allied Tube&Conduit Corp, 2"—4"on Dyna-Flow,Super-Flo pipe manufactured by Allied Tube&Conduit Corp, 1-1/4"-4"on FLF pipe manufactured by Western International Forest Products Inc., 1-1/4",2"-3"on SPS pipe manufactured by Yieh Phui Enterprise Co.,Ltd., 1-IA",2"-3"on Sch.5 pipe. 4-2)FM approved at 300 psi on the following sizes&pipes. 2-1/2",5"-6"on BS1387(M)medium or heavy grade pipe, 1-1/4",1-1/2"&4"on Fire-Flow(Allied)pipe, 1-1/2"&2"on Fire-Thread pipe, 1"—3"on Super40,Super-XL pipe, 1"-2"on TL(Central)&LS pipe. FM approved at 175 psi on the following sizes&pipes. 1-1/4"-3"on XL-II(Allied) pipe, 1-1/4"—2",3"-4"on BS1387 pipe, 1-I/4"--4"on Eddy-Flow,Super-Flo pipe, 1-1/4"-2"on BLT,Eddylite,WST(Wheatland),Gal-5(IDOD Systems)pipe, 1"-2"on Ultra Eddy(Bull Moose)pipe, 1-1/2"—4"on Eddy-Flow pipe. 5. 5-1)UL Listed at 300 psi on the following sizes&pipes. 2"-6"on BS1387(M),British Standard Medium Steel pipe pipe, 14"&16"on Sch.30 pipe, 18"&20"on Sch.20 pipe. UL Listed at250 psi in size 22"&24"on Sch.20 pipe. 5-2)FM approved at 175 psi in size 22"&24"on Sch.20 pipe. 6. 6-1)UL Listed at 300 psi on the following sizes&pipe. 1-1/4"--6"on BS1387 pipe,1-1/4"--3"on Super 40,Super-XL pipe,1-1/4"--4"on Dyna-Flow,Super-Flo pipe,1-1/4"-1-1/2"on Fire-Line Flow pipe,1-1/4"—2"on Fire-Thread pipe&Eddlylite pipe. UL Listed at 175 psi in size 1-1/4"--2"on Sch.5 pipe. 6-2)FM approved at 300 psi on the following sizes&pipes. 1-1/4"--6"on BS1387 pipe, 1-1/4"—3"on Super 40,Super-XL(Allied)pipe, I"—4"on Dyna-Flow,Super-Flo(Allied)pipe, 1"-2"on Ultra Eddy(Bull Moose)pipe, 13/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shudoint Piping Products • 1 800 746-GROOVED a Las Vegas,Nevada USA 9 www.shugoint.com SHURJOINT® FIRE PROTECTION PRODUCTS " wwuv.shudoint.com 1-1/2"-2"on Fire-Thread pipe, 1-1/4"-2"on Eddylite(Bull Moose),WST(Wheatland)pipe. 7. 7-1)UL Listed at 350 psi on the following sizes&pipe. 1-1/4"-4"on BS 1387(M)British Standard Medium Steel pipe pipe 2"--4"on Dyna-Flow,Super-Flo pipe manufactured by Allied Tube&Conduit Corp, UL Listed at 300 psi on the following sizes&pipe. 1-1/4"-2"on XL,BLT,WLT pipemanufactured by Allied Tube&Conduit Corp, 1-1/4"-2"on WLS manufactured by Wheatland Tube Cc 1-1/4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co. 1-1/4"-2"on Fire-Line Threadable pipe manufactured by Western International Forest Products Inc.1-1/4"-1-1/2"on Dyna-Flow, Super-Flo pipe manufactured by Allied Tabe&Conduit Corp, 1-1/4"-4"on Mega-Flow pipe manufactured by Wheatland Tube Co. 1-1/4"on Eddy Flow pipe manufactured by Bull Mosose Tube Co. 3"&4"on EZ-Flow pipe manufactured by Northwest Pipe Co., 1-1/4"&2"on MT pipe manufactured by Wheatland Tube Co. UL Listed at 175 psi on the following sizes&pipes. 1-1/2"—3"on Eddy Flow pipe manufactured by Bull Mosose Tube Co., 1-1/4"--2"on Sch.5 pipe, 6"on EZ-Flow pipe manufactured by Northwest Pipe Co.,. 7-2)FM approved at 350 psi in size 1-1/4"on XL pipe. FM approved at 300 psi on the following sizes&pipes. 2"-4"on Dyna-Flow,Super-Flo pipe, 1-lA"--4"on Mega-Flow pipe. FM approved at 175 psi on the following sizes&pipes. 2"--4"on Dyna-Flow,Super-Flo pipe, 1-1/4"--4"on Mega-Flow pipe. 1-1/2"-3"on Eddy Flow,Fire-Thread pipe. 8. 8-1)UL listed at 300 psi on the following sizes&pipe. 1-1/4"-4"on Dyna-Flow manufactured by Allied Tube&Conduit Corp.,and EF pipe manufactured by Bull Moose Tube Co.,and Mega-Flow pipe manufactured by Wheatland Tube Co. 3"—4"on EZ-Flow pipe manufactured by Northwest Pipe co 1-1/4"-2"on Eddylite pipe manufactured by Bull Moose Tube Co.,and MET,WLS pipe manufactured by Wheatland Tube Co. UL Listed at 175 psi on the following sizes&pipe. 1-1/4"-4"on Eddy Flow pipe manufactured by Bull Moose Tube Co. 1-1/4"-2"on Sch.5 pipe, 6"on EZ-Flow pipe manufactured by Northwest Pipe Co. 8-2)FM approved at 350 psi in size 1-1/4"-2"on XL pipe. FM approved at 300 psi in size 1-1/4"-4"on Mega-Flow pipe. FM approved at 175 psi in size 1-1/211-3"on Fire-Thread,Eddy Flow pipe. 9. 9-1)UL listed at 175 psi on the following pipe. 3"OD,4"-5"on BS1387(Ivi)British Standard Medium Steel pipe pipe, 12"on Sch.30(0.330 in)pipe.. 10"on Sch.10(0.188 in)pipe. 9-2) FM approved at 175 psi on the following pipe. 2-1/2,4 in.British Standard BS 1387 medium or heavy pipe. 2"—12",14",16"24"Min schedule cut groove pipe to be joined:8 in.or smaller Schedule 40. 2"—12",14",16"24"Min schedule rolled groove pipe to be joined:8 in.or smaller Schedule 10. 10. 10-1)UL listed at 300 psi in size 311x2"-2-1/2",4"x2-1/2"-3",6"x4"on BS1387 and 10-2)FM approved at 300 psi on BS1387(M)or heavy grade pipe. 11. UL listed at 175 psi in size 1-1/4"-2"on BS1387 pipe. 12. 12-1)UL listed at 300 psi in size 1-1/4"-2-1/2"on XL,Super-Flo pipe,175 psi in size 1-1/4"-2-1/2"on Dyna-Flow,XL-II,BS1387 pipe. 12-2)FM approved at 300 psi in size 1-1/4"-2-1/2"on Dyna-Flow,XL,Super-Flo(Allied)pipe,1-1/4"—2"on BLT(Allied)pipe,TL (Central),Eddylite(Bull Moose),WLS,LS (Wheatland)pipe. 13. 13-1)UL listed at 300 psi in size 2"x 2%"--8"x 4"on BS1387 pipe 13-2)UL listed at 300 psi in size 3"x 1%11-8"x 4"on BS1387 pipe 14.Light wall pipe shall be of the minimum wall thickness 0.188 in.Sch.10. 15.Rolled and Cut grooved basked on Sch.30(0.330")pipe. 16.Rolled and Cut grooved based on Sch.20(0.375 wall thickness pipe) 17.Rolled and Cut grooved based on Sch.30(0.375 wall thickness pipe) 18.Minimum schedule cut groove pipe to be joined:6"in or smaller-Sch.40;8"in or larger—Sch.30 19.Minimum schedule roll grooved pipe to be joined:6"or smaller—Sch.10,8 and 10"-0.188 in wall;12"-0.250 in wall. 20.UL listed at 300 psi in size 76.1mm,139.7mm,165.1mm on Sch.10S,46S pipe. 21.a)Provides a rigid transition between flanged components and a grooved system. b)Min schedule cut groove pipe to be joined:8 inches or smaller-Sch.40 c)Min schedule rolled groove pipe to be joined:8 inches or smaller—Sch.10. 14/14 SHURJOINT®IS AN ISO 9001 CERTIFIED COMPANY Shurjoint Piping Products • 1 800 746-GROOVED 9 Las Vegas,Nevada USA 9 www.shudoint.com ADJUSTABLE SWIVEL RING HANGERSA ' FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The knurled insert nut that allows a vertical adjustment after installation,is Fig. 141 & 141F to ped to NFPA reduced rod size standards. Fig.141F has a layer of felt NFPA SWIVEL which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.141 RING HANGER %"to 8"sizes only.Complies with Federal Specification A-A-1192A(Type 10),Manufacturers'Standardization Society SP-69(Type 10)and NFPA Fig. 141 PRE-GALVANIZED standards for reduced rod sizes. Fig. 141F PRE-GALVANIZED ORDERING: Specify pipe size and figure number. WITH FELT LINING Pipe $1Ze Ad* Max.Rec.Wt.Each = �A Size A B C D E Load/lbs. (in lbs.) - 1/2 % 17/8 17/16 23/4 31/16 300 .10 3/4 % 111/16 11/6 21/2 31/16 300 .10 - 1 3/6 15/e 1 21/2 33/16 300 1 .10 C 11/4 3/6 115/16 11/16 213/16 39/16 300 .11 �- I B 11/2 3/6 21/6 11/16 31/8 37/8 300 .11 2 3/8 2'/16 11/8 35/16 43/s 300 .14 �� D 21/2 3/s 23/4 11/4 311/16 5 525 .19 3 3/8 27/8 11/8 33/4 59/16 525 .23 ; 31/2 3/8 3% 13/6 45/16 66/16 525 .25 4 3/s 37/6 1112 41/2 7 650 :30 5 1/2 4% is/s 5% 8% 1000 .50 6 1/2 5% 21/4 61/2 913/16 1000 .58 8 1/2 613/16 27/,6 715/16 121/4 1000 .90 F O Note: If ordering Fig.141F felt lined hangers for pipe sizes of Yh"or under,order the next largest size to allow for the thickness of the felt lining. MATERIAL: Low carbon steel FUNCTION: Designed for the suspension of non-insulated stationary pipe lines.The Fig. 151 & 151E knurled insert nut,allows for vertical adjustment after installation. Fig.151F has a layer of felt which separates the pipe from the hanger to SWIVEL reduce vibration and sound. APPROVALS: Underwriters'Laboratories listed and Factory Mutual approved Fig.151 RING HANGER 21/2"to 8"sizes only.Complies with Federal Specification A-A-1192A (Type 10),and Manufacturers'Standardization Society SP-69(Type 10). Fig. 151 PRE-GALVANIZED ORDERING: Specify pipe size and figure number. Fig. 151F PRE-GALVANIZED WITH FELT LINING Rod Pipe Sze Adi. Max.Rec.Wt.Each `-.► A Size A B C p E Load/lbs. (in lbs.) _ 21/2 1/2 23/4 11/4 311/16 51/8 600 .33 3 1/2 31/s 11/8 4 57/8 600 .35 31/2 1/2 1 3% 11/2 45/16 6% 600 1 .37 C 4 % 37/8 11/4 415/16 71/s 1000 .48 13 5 % 4% 13/8 5% 81/2 1000 .57 �- 6 3/4 55/16 2 611/16 101/8 1250 1.06 . D 8 3/4 1 615/16 1 2% 85/16 127/s 1250 1.32 Note: If ordering Fig.151E elt lined hangers or pipe sizes of 3'h or under,order the next r { largest size to allow for the thickness of the felt lining. _ MATFRTAL• Tow carbon steel PHD Manufacturing, Inc. •44018 Columbiana-Waterford Road • Columbiana, OH 44408 Toll Free(800)321-2736•Phone: (330)482-9256•Fax: (330)482-2763•www.phd-mfg.com MALLEABLE IRON BEAM CLAMPS Fig. 350 FUNCTION: Designed for attaching hanger rod to the top flange of a beam or SEAM CLAMP bar joist,where the flange thickness does not exceed 3/4 inch.The open U design permits rod adjustment.The universal design of the 3/8 Fig.350 allows it to be used in an inverted position on the bottom flange of a beam as well. APPROVALS: Underwriters'Laboratories listed.Factory Mutual approved 3/8' and 1/2"sizes only. Complies with Federal Specification A-A-1192A D� (Type 19)and Manufacturers'Standardization Society SP-69(Type f 19).When used in an inverted position on the bottom of a beam flange the 3/8 Fig.350 also complies with Federal Specification A-A- 1192A(Type 23)and Manufacturers'Standardization Society SP-69 C (Type 23) MATERIAL: Ductile iron with hardened steel cup point set screw 3 3/4" 1 FINISH: Plain or electro-galvanized i4 ORDERING: Specify rod size,finish and figure number. A _tea Rod Max. Size Pipe Max. Rec. Wt. Each E� I A B C . D E Size Load/Ibs. (in Ibs.) B� A3/8 1 11/2 1% 1/2 4 400 .33 � 1/2 1 11/2 111/16 1/2 8 500 .34 5/8 11/16 11/2 17/8 5/8 8 600 .39 �JL FM 3/4 15/16 13/4 2% % 8 800 .63 7/8 15/16 13/4 23/8 % 8 1200 .60 Note: See MSS SP-69 specs for proper set screw torque values. 0 Reversible design approved for bottom beam use. PHD Manufacturing, Inc. •44018 Columbiana-Waterford Road • Columbiana, OH 44408 Toll Free(800)321-2736•Phone: (330)482-9256•Fax: (330)482-2763•www.phd-mfg.com ARGCO GUARANTEED THREADED ROD 'FASTENERS FOR STEEL - SIDE MOUNT FOR STEEL -One piece self drilling and tapping in steel up to 3/16"thick 25-30-526V RETAINER EMBEDMENT ITEM# ROD SIZE SHANK DIA. SHANK LENGTH NUT DEPTH LOAD CAPACITY APPROVALS 25-30-526V 3/8"-16 1/4" 1" 1" 1,500 U� 0 25-30-527V 3/8"-16 12-24 1-1/2" 1-1/2" 1,500 FM 25-30-528V 25-30-528V 3/8"-16 1/4" 1-1/2" 1-1/2" 1,500 FM SCREW SHANK POINT MAX. MINIMUM CROSS REFERENCE ITEM# &LENGTH STYLE PIPE SIZE STEEL THICKNESS UL TEST LOAD ELCO ITW SAMMY 25-30-526V 1/4"x 1" #3 4" .060"(1.5 MM) 1500 LBS. ITEM# HANGERMATE° SUPERSCREW' 25-30-527V 12/24"x 1-1/2" #3 4" .060"(1.5 MM) 1500 LBS. 25-30-526V EZH-476 SWDR-1 25-30-528V 1/4"x 1-1/2" #5 4" .060"(1.5 MM) 1500 LBS. 25-30-527V - SWDR-516 Recommended to be installed with 25-30-528V EZH-496 SWDR-15 Universal Steel&Wood Nut Driver(25-30-324V) ' . ^ SENSOR �����0�m Series ���� ������� ����� ����� ��������� �������������� �������~=� ������� �����~�"����� System SeD0r's WFD series is compatible with schedule /0 through 40 steel pipe,sizes 2^th rough 8^and can beCnOu0/ed/navertical Or horizontal position. Features Robust Construction.7heWFD�e,|�consists ofarugged, NEMA4 rated enclo �enclosure. ^Twn'|nch conduit openings in new VVFD]U'2models use,the VVFD series operates across a wide temperature range,from `UL||sted models are NEM84rated 32.Foo130rE 'Sealed retard mechan|sm|mmunemdustandothe,concaminamz Reliable Performance.UL listed models are equipped with tamper esimamcover sc*xwsmpns�m unauthorized emry|ngd� ^Visua|switchacbm�|on two sets of5PDT(Form[}synchronized switches are enclosed ina ^Field replaceable retard mechanism and 6PDTswitches durable terminal b|ockm assure reliable performance. .Rugged,dual SpDT switches enclosed ina durable terminal block False Alarm Ummmmunity.TheYVFD series incorporates amechanical ~Accommodates upml2AxGwire retard feature,which m|nimizes the risk of false alarm due m p�ssuresu�esor air tmppedinthe sphnk|ersystem.|naddition, ^De |gned�h/��hindoonbu�doo'u�e the mechanical nga»dt unique sealed design is immune m dust and ~l00 percent synchronization activates both alarm panel and other contaminants. local bell Simplified Operamiom.TheWFD series is designed msimplify ^Tamper resistant cover screws installation.Two conduit openings permit easy attachment tothe local alarm system.The retard mechanism and dual SPD7mwinches ae0dd'ep|aceab|e. Agency L stings @ @ MM LISTED approved APFR� / Waterflow Detector Specifications Engineering Specifications Vane-type waterflow detectors shall be installed on system piping as'designated on the drawing and/or as specified herein.Detectors shall mount on any clear pipe span of the appropriate nominal size,either a vertical upflbw or horizontal run,at least 6-from any fittings which may change water direction, flow rate,or pipe diameter or no closer than 24"from a valve or drain.Detectors shall have a sensitivity in the range of 4 to 10 gallons per minute and a static pressure rating of 450 psi*for 2"-8"pipes.The detector shall respond to waterflow in the specified direction after a preset time delay which is field adjustable.The delay mechanism shall be a sealed mechanical pneumatic unit with visual indication of actuation.The actuation mechanism shall include a polyethylene vane inserted through a hole in the pipe and connected by a mechanical linkage to the delay mechanism.Outputs shall consist of dual SPDT switches(Form C contacts).Two conduit entrances for standard fittings of commonly used electrical conduit shall be provided on the detectors. A grounding provision is provided.Unless noted,enclosures shall be NEMA 4 listed by Underwriters Laboratories Inc.All detectors shall be listed by Underwriters Laboratories Inc.for indoor or outdoor use. I Standard Specifications Static Pressure Rating 450 PSI* Operating Temperature Range 32aF to 120oF(O°C to 49oQ Maximum Surge 18 Feet Per Second(FPS) Enclosure Rating* NEMA 4-suitable for indoor/outdoor use Triggering Threshold 4-10 GPM Cover Tamper Switch Standard with ULC models,optional for UL Bandwidth(Flow Rate) models,part no.546-7000 Conduit Entrances Two openings for 1/2-conduit. Service Use Automatic Sprinkler:NFPA-13 One open,one knock-out type One orTwo Family Dwelling:NFPA 13D Residential Occupancies up to 4 Stories:NFPA 13R National Fire Alarm Code:NFPA-72 Contact Ratings Two sets of SPOT(Form Q U.S.Patent Numbers 3,845,259 10.0 A,1/2 HP @ 125/250 VAC 4,782,333 2.5 A @ 6/12/24 VDC 5,213,205 Compatible Pipe Steel water pipe,schedule 10 through 40 Warranty 3 Years WFDE Field Wiring Diagram Delay Adjustment Dial Overall Dimensions,Installed Delay Camnw us n end Scwmcmv DONTADTRATINOS di.]adjustment 2�cV a 0 '14� .s. I ccosa wDan vane is 1-tatl.i.e,wfienwe le IPS26o VAC IDAMP6 IIaMnB Duet hee ppee X O —_—m Lra4analoge cambinotl Be VDC ]sAMPS q a� Motlel WItlID Motle WI I tlnBb dat 3.0' WFDPO dfi' WFDaO 6e' L WFDP6 16' WFo50 7.e' WFD WFD 45 WFDe62 62' WFT)fin 9.0' WFD36 5.]' WFDee 10.9' I a • e To mn lenmeNe m Hme Its'. mne mvsror Uboll nutWT"ab fLetaOPlpe eeddle TypmvFACP e*nn.euon NOTE:Retard tune may exceed 9D semads. Adjust and verity that time does not exceed Bo seconds. pipo co eIOtal Plaadavane � ofmrmecDon DO NOTelbavnllauslnB.aDONOTb%pwoepe UDollTyPI Lo 1CanncNan• h•ammbty Ordering Information UL Model ULC Model Pipe Size Hole Size Shipping Weight WFD20 WFD20A 2" 11/4" 4.2lbs. WFD25 WFD25A 21/2" 11/4" 4.3lbs. WFD30-2 WFD30-2A 3" 2" 4.5lbs. WFD35 WFD35A 31/2" 11/4" 4.7lbs. WFD40 WFD40A 4" 2" 5.2lbs. WFD50 WFD50A 5" 2" 6.31bs. WFD60* WFD60A 6" 2" 6.81bs. WFD80* WFD80A 8" 2" 7.5lbs. Accessories A3008-00 Retard mechanism A77-01-02 Terminal block 546-7000 Tamper proof switch kit WFDW Tamper proof wrench for cover WFDN4 Gasket kit *Maximum pressure rating 400 psi as approved by Factory Mutual. "STE/Vl 020076yste pout or. �E/0/%S®R* 3825 Ohio Avenue•St.Charles,IL 60174 Product mproductI subject0on,i angewthoutnstvers ofthis an sheet. Phone:800-SENSOR2•Fax:630-377-6495 anent produalnfo maDon,indudung the 3/07.0 erslon o(h da asheet. A05-0IBD-011.3/07•p1676 FS10 SERIES (E) POTTER The Symbol of Protection PRESSURE SWITCH UL, cUL,.and CSFM Listed, FM and LPC Approved, NYMEA Accepted,CE Marked Dimensions:3.78"(9,6cm)W x 3.20"(8,1cm)D x 4.22"(10,7cm)H ©POTTER Conduit Entrance:Two knockouts provided for 1/2"conduit. Individual switch compartments and ground screws suitable for dissimilar voltages. PS10-2 �<> Enclosure: Cover-Die-cast with textured red powdercoat finish,single cover screw and rain lip. Base-Die-cast Pressure Connection:Nylon 1/2"NPT Male Factory Adjustment: 4-8 PSI(0,27-0,55 BAR) Differential: 2 PSI(0,13 BAR)typical Maximum System Pressure: 300 PSI(20,68 BAR) Switch Contacts: SPDT(Form C) 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC Ordering Information One SPDT in PS10-1,Two SPDT in PS10-2 Model Description Stock No. Environmental Specifications: PS10-1 Pressure switch with one set 1340103 NEMA 4/I1`66 Rated Enclosure-indoor or outdoor when used SPDT contacts with NEMA 4 conduit fittings. PS10-2 Pressure switch with two sets 1340104 Temperature range:-40°F to 140°F(-40°C to 60°C) SPDT contacts Service Use: Hex Key 5250062 Automatic Sprinkler NFPA-13 Cover Tamper Switch Kit 0090200 One or two family dwelling NFPA-13D Tamper Residential Occupancy up to four stories NFPA-13R Cover incorporates tamper resistant fastener that requires a special key for National Fire Alarm Code NFPA-72 removal.One key is supplied with each device. For optional cover tamper switch kit,order Stock No.0090200. See bulletin#5401200 PSCTSK. Installation The Potter PS10 Series Pressure Actuated Switches are designed for the into alarm port piping on the input side of retard chamber and electrically detection of a waterflow condition in automatic fire sprinkler systems of connect PSI 0 to control unit that provides a retard to compensate for surges. particular designs such as wet pipe systems with alarm check valves,dry Insure that no unsupervised shut-off valves are present between the alarm pipe,preaction,or deluge valves. The PS10 is also suitable to provide a check valve and PS 10. low pressure supervisory signal;adjustable between 4 and 15 psi(0,27 and Method 2: When using the PS10 for local bell application or with a control 1,03 BAR). that does not provide a retard feature-the PS 10 must be installed on the alarm 1.Apply Teflon tape to the threaded male connection on the device. outlet side of the retard chamber of the sprinkler system. (Do not use pipe dope) Testing: Accomplished by opening the inspector's end-of-line test valve. 2.Device should be mounted in the upright position(threaded connection down). Allow time to compensate for system or control retard. 3.Tighten the device using a wrench on the flats on the device. Note: Method 2 is not applicable for remote station service use,if there is an Wiring Instructions unsupervised shut-off valve between the alarm check valve and the PSI 0. 1.Remove the tamper resistant screw with the special key provided. Wet System With Excess Pressure 2.Carefully place a screwdriver on the edge of the knockout and Connect PSI 0 into alarm port piping extending from alarm check valve. sharply apply a force sufficient to dislodge the knockout plug.See Fig 9 Retard provisions are not required. Insure that no unsupervised shut-off 3.Run wires through an approved conduit connector and affix the connector valves are present between the alarm check valve and the PSI 0. to the device. Testing: Accomplished by opening the water by-pass test valve or the 4.Connect the wires to the appropriate terminal connections for the inspector's end-of-line test valve.When using end-of-line test,allow time service intended.See Figures 2,4,5,and 6.See Fig 7 for two switch,one for excess pressure to bleed off. conduit wiring. Dry System Testing Connect PS10 into alarm port piping that extends from the intermediate The operation of the pressure alarm switch should be testedupon completion chamber of the alarm check valve. Install on the outlet side of the in-line of installation and periodically thereafter in accordance with the applicable check valve of the alarm port piping. Insure that no unsupervised shut-off NFPA codes and standards and/or the authority having jurisdiction valves are present between the alarm check valve and the PS10. (manufacturer recommends quarterly or more frequently). Testing:Accomplished by opening the water by-pass test valve. Wet System Note: The above tests may also activate any other circuit closer or water Method 1: When using PS10 and control unit with retard-connect PS10 motor gongs that are present on the system. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-0988/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5400928-REV D-1 PAGE 1 OF 3 12/10 POTTER PS10 SERIES The Symbol of Protection PRESSURE SWITCH Dimensions Switch Clamping Plate Terminal Fig. I t Fig.2 F47 GROUND I 2 m .87 m- SCREWS ---f ADJUSTMENT 172.97]� KNOB PEN 4.22 —11 [107.19] DWG#923-3 1/2"NPT 0 2.48 1.60 TI NT I (62.87] [40.64] ON 3.78 3.20 An uninsulated section of a single conductor [95.891 (81.281 should not be looped around the terminal and serve as two separate connections. The wire NOTE:To prevent leakage,apply Teflon tape sealant to male threads only. must be severed,thereby providing supervision of the connection in the event that the wire DWG#930-1 becomes dislodged from under the terminal. Typical Sprinkler Applications Fig.3 WET SYSTEM WITH WET SYSTEM WITHOUT DRY SYSTEM EXCESS PRESSURE EXCESS PRESSURE PS10 WATER WATER PS10 PS10 WATER MOTOR MOTOR MOTOR WATER MOTOR MOTOR O� '0 GONG GONG GONG GONG REVS CHECK WET REVS DRY VALVE REVS RE WET REVS SYSTEM VALVE VS ALARM SYSTEM ALARM SYSTEM K ALARM CHECK C.'- VALVE CHECK RETARD VALVE VALVE WATER WATER WATER BY-PAS BY-PASS OS&Y BY-PASS VALVE S S VALVE VALVE OS&Y BY-PAS VALVE VALVE VALVE VALVE DWG.ff923-2AA A CAUTION Closing of any shutoff valves between the alarm check valve and the PS 10 will render the PS 10 inoperative.To comply with NFPA-72 any such valve shall be electrically supervised with a supervisory switch such as Porter Model RBVS. Low Pressure Signal Connection Waterflow Signal Connection Local Bell For Waterflow Connection Fig.4 Fig.5 Fig.6 TO FIRE ALARM PANEL TO FIRE ALARM PANEL NEGATIVE DC OR NEUTRAL AC BELL POSITIVE DC LINE LOAD ORHOTAC 0 0 0 0-L fc 0@ D.&91 1 DWG4 9 3 PRINTED IN USA NEG.#5400928-REV D-I PAGE 2 OF 3 12/10 MODEL PS40 (VdS) (2,) POTTER The Symbol of Protection `" SUPERVISORY PRESSURE SWITCH `UL, cUL, and CSFM Listed, FM and LPC Approved, NYMEA Accepted,CE Marked,VdS Dimensions:(9,6cm)3.78"W x(8,lcm)3.20"D x(10,7cm)4.22"H Conduit Entrance: Two knockouts provided for 1/2"conduit.Individual T i switch compartments and ground screw suitable for dissimilar voltages. P Enclosure: Cover-Die-cast with textured red powdercoat finish,single cover screw and rain lip. Base-Die-cast Pressure Connection:Nylon 1/2"NPT male Factory Adjustment: PS40-1 operates on decrease at 2,1 BAR(30 PSI) PS40-2 operates in increase at 3,5 BAR(50 PSI)and on decrease at 2,1 BAR(30 PSI) Pressure Range: 0,7-4,1 BAR(10-60 PSI) Differential: Typical 0,07 at 0,7 BAR(1 lb.at 10 PSI) 0,28 at 4,1 BAR(4 lbs.at 60 PSI) Maximum System Pressure: 17,2 BAR(250 PSI) Switch Contacts: SPDT(Form C) 10.1 Amps at 125/250VAC,2.0 Amps at 30VDC One SPDT in PS40-1,Two SPDT in PS40-2 Models: PS40-1 VDS Environmental Specifications: PS40-2 VDS NEMA 4/IP66 Rated Enclosure-indoor or outdoor when used with NEMA 4 conduit fittings. Service Use = Temperature range:-40°C to 60°C(-40°F-140°F) Automatic Sprinkler NFPA-13 Tamper: Cover incorporates tamper resistant fastener that requires a One or two family dwelling NFPA-13D special key for removal. One key is supplied with each device. Residential Occupancy up to four stories NFPA-13R For optional cover tamper switch kit,order Stock No.0090200. National Fire Alarm Cade NFPA-72 See bulletin#5401200 PSCTSK. Installation Adjustment And Testing The PotterPS40 Series Supervisory PressureActuated Switches are designed The operation of the supervisory pressure switch should be tested upon primarily to detect an increase and/or decrease from normal system pressure completion of installation and periodically thereafter in accordance with in automatic fire sprinkler systems. Typical applications are: Dry pipe the applicable NFPA codes and standards and/or the authority having systems,pre-action air/nitrogen supervision,pressure tanks, air supplies, jurisdiction(manufacturer recommends quarterly or more frequently). and water supplies. The PS40 switch is factory set for 2,8 BAR(40 PSI) normal system pressure. The switch marked with the word LOW is set to Note. Testing the PS40 may activate other system connected devices. operate at a pressure decrease of,7 BAR(10 PSI)at 2,1 BAR(30 PSI). The The use of a Potter BVL(see product bulletin 8900067 for details)is switch marked with the word HIGH is set to operate at a pressure increase recommended to facilitate setting and testing of the PS40 pressure switch. of,7 BAR(10 PSI)at 3,5 BAR(50 PSI). See section heading Adjustments When a BVL(bleeder valve)is used,the pressure to the switch can be and Testing if other than factory set point is required. isolated and bled from the exhaust port on the BVL without effecting the 1. Connect the PS40 to the system side of any shutoff or check valve. supervisory pressure of the entire system. See Fig.3 2. Apply Teflon tape to the threaded male connection on the device. (Do not use pipe dope) The operation point of the PS40 Pressure Switch can be adjusted to any 3. Device should be mounted in the upright position. point between 0,7-4,11 BAR(10 and 60 PSI)by turning the adjustment (Threaded connection down) knob(s)clockwise to raise the actuation point and counter clockwise to 4. Tighten the device using a wrench on the flats on the device. lower the actuation point. In the case of the PS40-2,both switches operate Wiring Instructions independent of each other. Each switch may be independently adjusted to 1. Remove the tamper resistant screw with the special key provided. actuate at any point acrosss the switch adjustment range. Initial adjustment 2. Carefully place a screwdriver on the edge of the knockout and sharply can be made with a visual reference from the top of the adjustment knob apply a force sufficient to dislodge the knockout plug. See Fig.9 across to the printed scale on the switch bracket. Final adjustments should 3. Run wires through an approved conduit connector and affix be verified with a pressure gauge. the connector to the device. A NEMA-4 rated conduit fitting is required for outdoor use. 4. Connect the wires to the appropriate terminal connections for the service intended.See Figures 2,4,5,6,and 8 PotterElectric Signal Company•St.Louis,MO•Customer Service:866-572-3005•Tech Support:866-956-0988•Canada 888-882-1833•www.pottersignal.com PRINTED IN USA WG.#5401161-REV D PAGE 1 OF 8 09/12 MODEL PS40 (VdS) (E)POTTER The Symbol of Protection SUPERVISORY PRESSURE SWITCH Dimensions Switch Clamping Plate Terminal Fig.1 Fig.2 GROUND 00 SCREWS 2.87 I I 172.971 I ADJUSTMENT ®KNOB � 4.22[107.19] �VGp 1/2"NPT _e --- Q% 2.48 1.60 ��j0�0 DWGk 9233 [62.87] [40.64] O 378 3. AWARNING [95.69] [81.2.28] C NOTE:To prevent leakage,apply teflon tape sealant to male threads only. An uninsulated section of a single conductor should not be looped around the terminal and AWAt NI I I NLGM serve as two separate connections. The wire must be severed,thereby providing supervision Use of pipe joint cement may result in obstruction of the aperture and loss of the connection in the event that the wire of signal. becomes dislodged from under the terminal. Typical Sprinkler Applications Fig.3 PS40 SUPERVISORY PRESSURE SWITCH A CAUTION AIR LINE Closing of any shutoff valves between the VALVEHUT-OFF BLEEDER ALARM alarm check valve and the PS10 will render TEST PRESSURE the PSI inoperative.To comply with IBC, CHECK VALVEVALVE BVL SWITCH IFC,and NFPA-13,any such valve shall be WATER electrically supervised with a supervisory __> MOTOR switch such as Potter Model RBVS GONG CHECK REVS DRY PIPE VALVE VALVE WATER DWG.#924-1A OS&Y BY-PASS VALVE TEST VALVE Typical Connections Fig.4 PS40-1 PS40-2 WITH NORMAL SYSTEM PRESSURE TO FIRE APPLIED LOW-TERMINAL 2 CLOSES ALARM ON PRESSURE DROP. PANEL WF9 ; HIGH COM2L"^ AIR COM COM I 1 11 2 WITH NORMAL SYSTEM EOLR LAIR PRESSURE APPLIED HIGH TO FIRE V -TERMINAL I WILL CLOSE ALA ON PRESSURE INCREASE. PANEL �\ EOLR PRINTED IN USA MFG.#5401161- REV D PAGE 2 OF 8 09/12 AIR PRODUCTS �", t`ie Pew WecU"o 17ctee"tvp Olrrs OILLESS RISER MOUNTED COM_P_RE_SS_ORS - _ _ - r rS rl__ -___ for Dry Pipe Sprinkler5ystenis -= le - 112"Outlet Connections { U - Thermal Overload Protection C us - Riser Mounting Kit Included with "AC"Models Fully Automatic - Fills System to 40 PSI in 30 Minutes (NFPA 13) - - Direct Drive ' -Air Intake Filter(s) c► f - Oil Less Piston Compressor - UL Listed Pressure Switch +j - Bubble Tight Air Check Valve - Permanently Lubricated Bearings de__Un t5--50 Cycle Available-Consult-Facto -- — - - - System Model Average Motor Min. Wire Dimensions Weight Capacity Number CFM* H.P. Size ++ L W H (gallons)** 110 OL11016AC 1.33 1/6 12 14 9 9 31 215_ OL21533AC 2.61 1/3 10 16 9 10 37 i 335 OL33550AC 4.06 1/2 8 16 11 9 49 425 OL42575AC 5.27 3/4 8 20 14 10 54 610 OL610V100AC 7.40 1 8 20 14 10 55 900 OL900V150AC 10.91 11/2 6 26 17 14 78 1200$ OL120OV200AC 14.55 2 10 26 17 14 78 *Average CFM is the average free air delivery from 0 to 40 PSIG. O ++ Based on 100 foot run. H Consult Factory for longer or shorter runs. **Based on 70 degree F system temp. For other conditions consult factory for pump up times. L W $-230 volt only, all other units 115/230 volt. 3 Phase Units available-Consult Factory. Magnetic Line Starters - Thermal Overload Protection 9 Air Maintenance Device Single Phase j Part#AMD-1 115_V 230V _ S_ ize Model f'' °' The AMD-1 is used when 1/3 HP 1 HP 00 MGOOA* compressed air is supplied through an existing factory air supply or when Maximum 1 HP 2 HP 0 MGXOA* using tank mounted units. HP 2 HP 3_HP 1 MG01A* !_3 HP 5 HP 1P MG15A* Call 1-800-345-8207 When Ordering a Magnetic Line Starter you must specify Fax: 610-524-8965 HP, Voltage and Phase that is supplied to the motor. E-Mail: genairpro@generalairproducts.com Remember-You can rind this sheet and more at www.GENERALAIRPRODUCTS.com RISER MOUNT OIL-LESS COMPRESSORS *** GENERAL INSTALLATION INSTRUCTIONS ** AIR PRODUCTS,INC. ALL PIPING AND WIRING TO BE IN ACCORDANCE WITH APPLICABLE STATE, LOCAL IF SYSTEM IS FEEDING FREEZER AND NATIONAL CODES& ROOM OR AREA EXPOSED TO TEMPERATURES BELOW SHOULD BE APPROVED BYAHJ CONNECT TO REQUIRED MULTIPLE CHECK ISEE DRY AIR PAC FORMATIOIN.11 SYSTEM TRIM VALVES IN FEED LINES CAN RESULT IN LOWER SYSTEM PRESSURES DUE TO PRESSURE DROPS ril 200 F MAX. ACCELERATOR T O D P V TANK MOUNTED UNITS ARE %' RECOMMENDED FOR USE WITH ACCELERATORS PRESSURE RELIEF VALVE PM VR3P25080 PiNMD-1 AIR M X ••• AIR MAINTENANCE DEVICE WARNING! DO NOT INSTALL IN AREAS EXPOSED TO 1/2"MINIMUM, TEMPERATURES LARGER IF REQUIRED BELOW 40 DEGREES F BY CODE. OR AREAS EXPOSED MANUAL DRAIN TO WEATHER. CONSULT •• RECOMMENDED AS L FACTORY FOR --- - - WEATHERPROOF OPTIONS. MINIMUM. FLEX HOSE OR PM P1202MP MAGNETIC STARTER AUTOMATIC DRAIN(P/N FD-1) REQUIRED FOR ALL RECOMMENDED ON DRIP LEG 3 PHASE UNITS AND SINGLE TO REMOVE EXCESS WATER. COPPER TUBING OR LARGER. ITS 1 HP AND RUBBER HOSE NOT RECOMMENDED DUE MOST MOTORS ARE MULTIPLE TO HIGH TEMPERATURES VOLTAGE.CHECK NAMEPLATE AND HIGH PRESSURE FOR CORRECT INTERNAL DROPS WHEN USED. CONNECTIONS FOR VOLTAGE �� BEING SUPPLIED TO UNIT. { X. J RISER MOUNTING KIT N AN AIR MAINTENANCE INCLUDED IN COMPRESSOR DEVICE IS USED MOVE SENSING PACKAGE LINE TO SYSTEM SIDE OF SYSTEM CHECK VALVE AND INSTALL PRESSURE SWITCH SETTING RELIEF VALVE(PM VR3P25080) IS 27#CUT IN 40#CUT OUT;FOR HIGHER PRESSURES CONSULT FACTORY PART NUMBERS LISTED ARE FOR ACCESSORY ITEMS RECOMMENDED FOR COMPLETE INSTALLATION-CONSULT YOUR LOCAL DISTRIBUTOR FOR AVAILABILITY OUS.TCW 10/4/00 11 ah - ARGCO GUARAN4EED FIRE ALARM BELLS • Four wire, 120 and 24 volt U� 10 DIA.GONG • Indoor and outdoor installation •Weatherproof backbox 120 VAC:. 6", 8", 10" / \ ; t 5" 24 VAC: 6", 10" 8"DIA.GONG -I--f� I �i 4„ / 3" 6"DIA.GONG 4-3/8" Base 3-29/32" 3-11/32" 3-15/32" RATING 60 GONG SIZE 80 GONG SIZE 100 GONG SIZE Rated Sound Level Rated Sound Level Rated Sound Level VOLTAGE Current at 1 Meter Current at 1 Meter Current at 1 Meter Co O O 6VDC 250mA 95dB 250mA 95dB 250mA 95dB 12VDC 180mA 95dB 180mA 95dB 180mA 96dB o o Back Box 24VDC 100mA 95dB 100mA 95dB 100mA 96dB 120VAC 25mA 95dB 25mA 95dB 25mA 98dB 220VAC 20mA 95db 20mA 95db I 20mA I 97db WIRING INSTRUCTIONS D.C. BELLS (observe polarity) A.C. BELLS RED(IN) RED(OUT) RED(IN) RED(OUT) O O from control panel or to next bell or from control panel or preceding bell end-of-line resistor preceding bell BLACK IN O O BLACK(OUT) BLACK IN O O BLACK OUT) When electrical supervisor is required use in and out leads as shown. When electrical supervisor is required use in and out leads as shown. 1. Observe polarity to ring DC bells 1. When using AC bells,terminate each extra wire separately 2. Red wires positive(+) after last bell 3. Black wires negative() 2. End-of-line resistor is not required on AC bells. INSTALLATION: 1.The bell should be mounted a minimum of 8 ft. from the floor or as close to the ceiling as possible. 2. Remove the gong 3. Connect the wiring (see diagram). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong(be sure that the gong positioning pin, in the mechanism housing, is in th hole in the gong). 6.Test all bells for proper operation that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). 800-854-1015 www.argco.com FAX 760-727-3270 Beneficial Fire Protection Page 1 FMC ZEPHYRHILLS WEST EXTERIOR ENTRANCE Date 070518 Hydraulic Design Information Sheet Name - Florida Medical Clinic Date - 7-5-18 Location - 36757 Eiland Blvd. Zephyrhills, Florida Building - System No. - Contractor - Beneficial Fire Contract No. - Calculated By - SG. Drawing No. - FP2 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - Varies Occupancy - Light Hazard -- Assembly -- No storage : S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 647 SF System Type Sprinkler/Nozzle Density - .10 ( ) Wet Make Globe D Area Per Sprinkler - 225 (X) Dry Model GL5634 E Elevation at Highest Outlet - 16.5 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 283.24 Press Required - 47.40 Riser Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 9-20-17 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 70 @ Press - R Residual Press - 50 Elev. - Well Flow - 993 Proof Flow S Elevation - 0 U P Location - Eiland Blvd. 450 feet east of Simons Rd. P L Source of Information - City of Zephyrhills Utilities Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: =W DATE °/ ✓ LANNCO,ir'C. �ROFE OF ZEPHYR ILLS `�(� ENGINEERING C-7 3ULTING AND.LIFE SAFETY EXAMINEt �_.,.. CERTIFICATE OF ti�a NORIZATION ALL WORK SHALL COMPP.O.LY WITH 13L;;41481 NFFA CODES AND STANDARDS 3T.PETE' :;URG FL0RIC;.:S3743 FRANI:C',(�';;<<: ^ 345•8556 FLOR16 E.,: - Water Supply Curve C Beneficial Fire Protection Page 2 FMC ZEPHYRHILLS WEST EXTERIOR ENTRANCE Date 070518 City Water Supply: Demand: C1 -Static Pressure 70 D1 - Elevation 7.146 C2- Residual Pressure: 50 D2- System Flow : 183.245 C2- Residual Flow 993 D2- System Pressure : 47.402 Hose ( Demand ) : 100 D3- System Demand :283.245 Safety Margin 20.634 150 140 130 P 120 R 110 E 100 S 90 S 80 C1 U 70 R 60 2 E 50 40 D3 30 20 10 D1 100 200 300 400 500 600 700 800 900 FLOW N ^ 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Beneficial Fire Protection Page 3 FMC ZEPHYRHILLS WEST EXTERIOR ENTRANCE Date 070518 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 .0 0 0 0 0 D Generic Dry Pipe Valve 0 0 0 0 0 0 9.5 17 0 28 0 47 0 0 0 0 0 0 0 0 E 90'Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Beneficial Fire Protection Page 4 FMC ZEPHYRHILLS WEST EXTERIOR ENTRANCE Date 070518 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. D001 11.5 5.6 16.14 na 22.5 0.1 225 7.0 D002 11.5 5.6 16.14 na 22.5 0.1 225 7.0 3A 16.5 K=K @ EQ01 21.69 na 22.5 3B 16.5 K=K @ EQ01 22.57 na 22.95 3C 16.5 K=Kg E001 21.83 na 22.57 3D 16.5 K=K @ EQ01 22.72 na 23.03 3E 14.17 K=K @ EQ01 21.76 na 22.53 3F 14.17 K=K @ EQ02 23.16 na 23.0 3G 14.17 K=K @ E001 22.86 na 23.1 3H 14.17 K=K @ EQ02 24.33 na 23.57 50 16.5 23.66 na 51 16.5 23.81 na 52 14.17 26.84 na 53 14.17 28.18 na 65 12.17 35.28 na DTOR 12.17 35.63 na DBOR 3.0 40.47 na BOR -3.0 43.23 na BFD 3.0 40.96 na BFS -3.0 48.62 na SRCE 0.0 47.4 na 100.0 The maximum velocity is 17.32 and it occurs in the pipe between nodes 3H and 53 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 •Final Calculations - Hazen-Williams Beneficial Fire Protection Page 5 FMC ZEPHYRHILLS WEST EXTERIOR ENTRANCE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ' "*'" Notes **" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 22.50 1.049 E 2.0 1.500 16.143 K Factor=5.60 to 120.0 0.0 2.000 4.981 EQ01 22.5 0.1617 0.0 3.500 0.566 Vel = 8.35 0.0 22.50 21.690 K Factor= 4.83 D002 22.50 1.049 T 5.0 1.500 16.143 K Factor= 5.60 to 120.0 0.0 5.000 4.981 EQ02 22.5 0.1618 0.0 6.500 1.052 Vel = 8.35 0.0 22.50 22.176 K Factor= 4.78 3A 22.50 1.049 T 5.0 7.170 21.690 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 50 22.5 0.1618 0.0 12.170 1.969 Vel = 8.35 0.0 22.50 23.659 K Factor= 4.63 3B 22.95 1.049 T 5.0 1.500 22.568 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 50 22.95 0.1678 0.0 6.500 1.091 Vel = 8.52 0.0 22.95 23.659 K Factor= 4.72 3C 22.57 1.049 T 5.0 7.170 21.832 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 51 22.57 0.1628 0.0 12.170 1.981 Vel = 8.38 0.0 22.57 23.813 K Factor= 4.63 3D 23.03 1.049 T 5.0 1.500 22.716 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 51 23.03 0.1688 0.0 6.500 1.097 Vel = 8.55 0.0 23.03 23.813 K Factor= 4.72 3E 22.53 1.049 0.0 8.670 21.757 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 3F 22.53 0.1623 0.0 8.670 1.407 Vel = 8.36 3F 23.00 1.049 T 5.0 1.170 23.164 K Factor @ node EQ02 to 120.0 • 0.0 5.000 0.0 52 45.53 0.5961 0.0 6.170 3.678 Vel = 16.90 0.0 45.53 26.842 K Factor= 8.79 3G 23.10 1.049 0.0 8.670 22.856 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 3H 23.1 0.1699 0.0 8.670 1.473 Vel = 8.58 3H 23.56 1.049 T 5.0 1.170 24.329 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 53 46.66 0.6238 0.0 6.170 3.849 Vel = 17.32 0.0 46.66 28.178 K Factor= 8.79 50 45.45 2.157 0.0 8.670 23.659 to 120.0 0.0 0.0 0.0 51 45.45 0.0178 0.0 8.670 0.154 Vel = 3.99 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 6 FMC ZEPHYRHILLS WEST EXTERIOR ENTRANCE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 51 45.60 2.157 3E 18.46 13.000 23.813 to 120.0 0.0 18.460 1.009 52 91.05 0.0642 0.0 31.460 2.020 Vel = 7.99 52 45.53 2.157 0.0 9.830 26.842 to 120.0 0.0 0.0 0.0 53 136.58 0.1359 0.0 9.830 1.336 Vel = 11.99 53 46.66 2.157 3E 18.46 8.160 28.178 to 120.0 0.0 18.460 0.866 65 183.24 0.2341 0.0 26.620 6.232 Vel = 16.09 0.0 183.24 35.276 K Factor= 30.85 65 183.24 4.26 2E 26.334 15.500 35.276 to 120.0 0.0 26.334 0.0 DTOR 183.24 0.0085 0.0 41.834 0.356 Vel = 4.12 0.0 183.24 35.632 K Factor= 30.70 DTOR 183.24 4.26 E 13.167 9.170 35.632 to 120.0 B 15.8 92.169 3.972 DBOR 183.24 0.0085 D 36.868 101.339 0.862 Vel = 4.12 T 26.334 DBOR 0.0 4.31 E 13.937 6.000 40.466 to 120.0 0.0 13.937 2.599 BOR 183.24 0.0080 0.0 19.937 0.160 Vel = 4.03 0.0 183.24 43.225 K Factor= 27.87 BOR 183.24 6.09 3E 64.749 251.000 43.225 to 150.0 2F 21.583 86.332 -2.599 BFD 183.24 0.0010 0.0 337.332 0.334 , Vel = 2.02 BFD 0.0 6.09 Zid 0.0 6.000 40.960 to 150.0 E 21.583 21.583 7.629 ** Fixed Loss=5.03 BFS 183.24 0.0010 0.0 27.583 0.027 Vel = 2.02 BFS 0.0 6.09 E 21.583 14.000 48.616 to 150.0 G 4.625 72.457 -1.299 SRCE 183.24 0.0010 T 46.249 86.457 0.085 Vel = 2.02 100.00 Qa= 100.00 283.24 47.402 K Factor= 41.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 A Beneficial Fire Protection Page 1 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 Hydraulic Design Information Sheet Name - Florida Medical Clinic Date - 7-5-18 Location - 36757 Eiland Blvd. Zephyrhills, Florida Building - System No. - Contractor - Beneficial Fire Contract No. - Calculated By - SG Drawing No. - FP2 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - 9'-0" Occupancy - Light Hazard-- Offices S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C (X) Figure 11.2.3.2.3.1 Curve Qr Head Red S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 978 SF System Type Sprinkler/Nozzle Density - .10 (X) Wet Make Globe D Area Per Sprinkler - 220 ( ) Dry Model GL5601 E Elevation at Highest Outlet - 24.67 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 352.46 Press Required - 54.24 Riser Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 9-20-17 Cap. - T Time of Test - - Rated Cap.- Elev.- E Static Press - 70 @ Press - R Residual Press - 50 Elev. - Well Flow - 993 Proof Flow S Elevation - 0 U P Location - Eiland Blvd. 450 feet east of Simons Rd. P L Source of Information - City of Zephyrhills Utilities Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled o Palletized o Rack M ( ) Single Row ( ) Con ven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: LANNCO' ,I!,C. REVIEW DATE ENGINEERING GC",S ULTING CITY OF ZEPHYRHILLS CERTIFICATE OF A: NORIZATION FIRE AND LIFE SAFETY EXAMINER-A& _ #20222 P.O.130f 4-; 31 ALL WORK SHALL COMPLY WITH ST.PETE R'SBURG NFFA CODES AND STANDARDS FLORID 1 Z3743 'FRANK�ONGi4?. j (727)345-8556 FL691DA P:I:.547 . Water Supply Curve C Beneficial Fire Protection Page 2 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 City Water Supply: Demand: C1 -Static Pressure : 70 D1 - Elevation 10.685 C2- Residual Pressure: 50 D2-System Flow :252.467 C2- Residual Flow 993 D2-System Pressure 54.247 Hose ( Demand ) : 100 D3-System Demand :352.467 Safety Margin 12.809 150 140 130 P 120 R 110 E 100 S 90 S 80 C1 U 70 R 60 02 2 E 50 D3 40 30 20 10 D1 100 200 300 400 500 600 700 800 900 FLOW ( N " 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Beneficial Fire Protection Page 3 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90'Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S Generic Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 65 76 87 98 109 130 T 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Beneficial Fire Protection Page 4 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. D001 11.5 5.6 15.43 na 22.0 0.1 220 7.0 D002 11.5 5.6 7.0 na 14.82 0.1 120 7.0 2A 24.67 K=K @ EQ01 28.83 na 25.85 2D 24.67 K=K @ EQ01 20.88 na 22.0 2F 24.67 K=K @ EQ01 22.26 na 22.72 2G 24.67 K=K @ EQ01 24.46 na 23.81 2H 24.67 K=K @ EQ01' 28.6 na 25.75 21 24.67 K=K @ EQ01 24.19 na 23.68 213 24.67 K=K @ EQ02 28.41 na 22.4 2C. 24.67 K=K @ EQ02 29.05 na 22.65 14 24.67 22.57 na 2E 24.67 K=K @ EQ02 22.79 na 20.07 15 24.67 23.42 na 16 24.67 25.46 na 17 24.67 25.93 na 2J 24.67 K=K @ EQ02 26.28 na 21.55 2K 24.67 K=K @ EQ02 27.39 na 21.99 30 24.67 30.94 na 31 24.67 30.94 na 32 24.67 30.99 na 33 24.67 31.14 na 34 24.67 31.31 na 35 24.67 34.06 na 36 24.67 35.4 na 37 24.67 36.04 na 44 11.5 41.94 na 43 11.5 43.34 na TOR 11.5 44.63 na BOR -3.0 52.01 na BFD 3.0 50.02 na BFS -3.0 55.39 na SRCE 0.0 54.25 na 100.0 The maximum velocity is 15.34 and it occurs in the pipe between nodes 16 and 32 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 •Final Calculations - Hazen-Williams Beneficial Fire Protection Page 5 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 22.00 1.049 E 2.0 1.000 15.434 K Factor=5.60 to 120.0 0.0 2.000 4.981 EQ01 22.0 0.1550 0.0 3.000 0.465 Vel = 8.17 0.0 22.00 20.880 K Factor= 4.81 D002 14.82 1.049 T 5.0 1.000 7.000 K Factor=5.60 to 120.0 0.0 5.000 4.981 EQ02 14.82 0.0747 0.0 6.000 0.448 Vel = 5.50 0.0 14.82 12.429 K Factor= 4.20 2A 25.85 1.049 E 2.0 8.080 28.829 K Factor @ node EQ01 to 120.0 0.0 2.000 0.0 30 25.85 0.2092 0.0 10.080 2.109 Vel = 9.60 0.0 25.85 30.938 K Factor= 4.65 2D 22.00 1.049 E 2.0 3.880 20.880 K Factor @ node EQ01 to 120.0 T 5.0 7.000 0.0 14 22.0 0.1552 0.0 10.880 1.689 Vel = 8.17 0.0 22.00 22.569 K Factor= 4.63 2F 22.72 1.049 T 5.0 2.000 22.265 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 15 22.72 0.1647 0.0 7.000 1.153 Vel = 8.43 0.0 22.72 23.418 K Factor= 4.69 2G 23.81 1.049 T 5.0 0.540 24.463 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 16 23.81 0.1798 0.0 5.540 0.996 Vel = 8.84 0.0 23.81 25.459 K Factor= 4.72 2H 25.75 1.049 T 5.0 7.250 28.597 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 33 25.75 0.2076 0.0 12.250 2.543 Vel = 9.56 0.0 25.75 31.140 K Factor= 4.61 21 23.68 1.049 T 5.0 4.750 24.191 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 17 23.68 0.1779 0.0 9.750 1.735 Vel = 8.79 0.0 23.68 25.926 K Factor= 4.65 2B 22.40 1.536 2E 10.108 15.500 28.413 K Factor @ node EQ02 to 120.0 0.0 10.108 0.0 2C 22.4 0.0251 0.0 25.608 0.642 Vel = 3.88 2C 22.66 1.536 T 10.108 10.580 29.055 K Factor @ node EQ02 to 120.0 0.0 10.108 0.0 31 45.06 0.0913 0.0 20.688 1.888 Vel = 7.80 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 6 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "*'"` Notes Point Qf Pf/Ft Eqv. Ln. Total Pf Pn 45.06 30.943 K Factor= 8.10 14 22.00 1.536 0.0 9.330 22.569 to 120.0 0.0 0.0 0.0 2E 22.0 0.0242 0.0 9.330 0.226 Vel = 3.81 2E 20.07 1.536 0.0 7.750 22.795 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 15 42.07 0.0804 0.0 7.750 0.623 Vel = 7.28 15 22.71 1.536 0.0 11.420 23.418 to 120.0 0.0 0.0 0.0 16 64.78 0.1787 0.0 11.420 2.041 Vel = 11.22 16 23.82 1.536 T 10.108 7.250 25.459 to 120.0 0.0 10.108 0.0 32 88.6 0.3189 0.0 17.358 5.535 Vel = 15.34 0.0 88.60 30.994 K Factor= 15.91 17 23.68 1.536 0.0 12.875 25.926 to 120.0 0.0 0.0 0.0 2J 23.68 0.0277 0.0 12.875 0.357 Vel = 4.10 2J 21.55 1.536 0.0 12.000 26.283 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 2K 45.23 0.0919 0.0 12.000 1.103 Vel = 7.83 2K 21.99 1.536 T 10.108 10.420 27.386 K Factor @ node EQ02 to 120.0 0.0 10.108 0.0 34 67.22 0.1913 0.0 20.528 3.928 Vel = 11.64 0.0 67.22 31.314 K Factor= 12.01 30 25.85 3.314 0.0 7.330 30.938 to 120.0 0.0 0.0 0.0 31 25.85 0.0007 0.0 7.330 0.005 Vel = 0.96 31 45.06 3.314 0.0 10.170 30.943 to 120.0 0.0 0.0 0.0 32 70.91 0.0050 0.0 10.170 0.051 Vel = 2.64 32 88.59 3.314 0.0 6.540 30.994 to 120.0 0.0 0.0 0.0 33 159.5 0.0223 0.0 6.540 0.146 Vel = 5.93 33 25.75 3.314 0.0 5.875 31.140 to 120.0 0.0 0.0 0.0 34 185.25 0.0296 0.0 5.875 0.174 Vel = 6.89 34 67.22 3.314 E 10.191 42.330 31.314 to 120.0 0.0 10.191 0.0 35 252.47 0.0523 0.0 52.521 2.747 Vel = 9.39 35 0.0 4.31 T 27.874 64.170 34.061 to 120.0 0.0 27.874 0.0 36 252.47 0.0145 0.0 92.044 1.339 Vel = 5.55 36 0.0 4.31 E 13.937 13.580 35.400 to 120.0 B 16.724 30.661 0.0 37 252.47 0.0146 0.0 44.241 0.644 Vel = 5.55 0.0 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 7 FMC ZEPHYRHILLS 2ND FLOOR REMOTE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ... *" Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 252.47 36.044 K Factor= 42.05 37 252.47 4.31 0.0 13.170 36.044 to 120.0 0.0 0.0 5.704 44 252.47 0.0146 0.0 13.170 0.192 Vel = 5.55 44 0.0 4.31 2E 27.874 68.540 41.940 to 120.0 0.0 27.874 0.0 43 252.47 0.0145 0.0 96.414 1.402 Vel = 5.55 43 0.0 4.31 3E 41.811 46.795 43.342 to 120.0 0.0 41.811 0.0 TOR 252.47 0.0145 0.0 88.606 1.289 Vel = 5.55 0.0 252.47 44.631 K Factor= 37.79 TOR 252.47 4.31 E 13.937 14.500 44.631 to 120.0 B 16.724 61.322 6.280 BOR 252.47 0.0145 S 30.661 75.822 1.103 Vel = 5.55 0.0 252.47 52.014 K Factor= 35.01 BOR 252.47 6.09 3E 64.749 251.000 52.014 to 150.0 2F 21.583 86.332 -2.599 BFD 252.47 0.0018 0.0 337.332 0.604 Vel = 2.78 BFD 0.0 6.09 Zid 0.0 6.000 50.019 to 150.0 E 21.583 21.583 5.324 '" Fixed Loss=2.725 BFS 252.47 0.0018 0.0 27.583 0.049 Vel = 2.78 BFS 0.0 6.09 E 21.583 14.000 55.392 to 150.0 G 4.625 72.457 -1.299 SRCE 252.47 0.0018 T 46.249 86.457 0.154 Vel = 2.78 100.00 Qa= 100.00 352.47 54.247 K Factor= 47.86 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Beneficial Fire Protection Page 1 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 Hydraulic Design Information Sheet Name - Florida Medical Clinic Date - 7-5-18 Location - 36757 Eiland Blvd. Zephyrhills, Florida Building - System No. - Contractor - Beneficial Fire Contract No. - Calculated By - SG Drawing No. - FP2 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - Varies Occupancy - Ordinary Hazard I -- Porte Cochere S (X) NFPA 13 ( ) Lt. Haz. Ord.Haz.Gp. (X) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 2036 SF System Type Sprinkler/Nozzle Density - .15 ( ) Wet Make Globe D Area Per Sprinkler - 130 (X) Dry Model GL5634 E Elevation at Highest Outlet - 17.5 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.200 G Hose Allowance - Outside - 250 N Note Calculation Flow Required - 564.17 Press Required- 52.51 Riser Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 9-20-17 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 70 @ Press - R Residual Press - 50 Elev. - Well Flow - 993 Proof Flow S Elevation - 0 U P Location - Eiland Blvd. 450 feet east of Simons Rd. P L Source of Information - City of Zephyrhills Utilities y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled o Palletized o Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: , LANNCO,FIC. REVIEW DATE ��'1�� ENGINEERING G' '3ULTING = CITY OF ZEPHYRHILLS CERTIFICATE OF A:i 0RIZATION FIRE AND LIFE SAFETY EXAMINE - P.O.B 0;'f 41�31 ALL WORK SHALL C:Uivi'r'LI vvi ST.PETE ,"DLIRG 1 NFFA CODES AND STANDARDS FLORID S3743 NK 80N (7. -,3 5.8556 FLORIDA P.E.-5470, e Water Supply Curve C Beneficial Fire Protection Page 2 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 City Water Supply: Demand: C1 -Static Pressure : 70 D1 - Elevation 7.579 C2- Residual Pressure: 50 D2-System Flow :314.172 C2- Residual Flow 993 D2-System Pressure 52.515 Hose ( Demand ) :250 D3-System Demand : 564.172 Safety Margin 10.458 150 140 130 P 120 R 110 E 100 S 90 S 80 C1 U 70 R 60 D2 2 E 50 40 D3 30 20 10 LD1 100 200 300 400 500 600 700 800 900 FLOW ( N 11 1.85 ) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Beneficial Fire Protection Page 3 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 D Generic Dry Pipe Valve 0 0 0 0 0 0 9.5 17 0 28 0 47 0 0 0 0 0 0 0 0 E 90'Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Beneficial Fire Protection Page 4 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. D001 11.5 5.6 12.13 na 19.5 0.15 130 7.0 D002 11.5 5.6 12.13 na 19.5 0.15 130 7.0 4C 17.5 K=K @ EQ01 22.35 na 22.01 4F 17.5 K=K @ EQ01 22.44 na 22.06 41 17.5 K=K @ EQ01 22.87 na 22.26 4L 17.5 K=K @ EQ01 23.6 na 22.62 4M 15.17 K=K @ EQ01 21.0 na 21•.34 4N 15.17 K=K @ EQ01 22.33 na 22.0 40 15.17 K=K @ EQ01 22.33 na 22.0 4A 17.5 K=K @ EQ01 17.54 na 19.5 413 17.5 K=K @ EQ02 18.95 na 20.06 4D 17.5 K=K @ EQ01 17.62 na 19.54 4E 17.5 K=K @ E002 19.03 na 20.1 4G 17.5 K=K @ EQ01 17.95 na 19.73 4H 17.5 K=K @ EQ02 19.39 na 20.29 4J 17.5 K=K @ EQ01 18.54 na 20.05 4K 17.5 K=K @ EQ02 20.02 na 20.62 18 15.17 22.58 na 19 15.17 24.0 na 60 17.5 23.97 na 61 17.5 24.07 na 62 17.5 24.52 na 63 17.5 25.3 na 64 15.17 33.98 na 65 12.17 39.43 na DTOR 12.17 40.39 na DBOR 3.0 46.7 na BOR -3.0 49.74 na BFD 3.0 48.04 na BFS -3.0 53.58 na SRCE 0.0 52.52 na 250.0 The maximum velocity is 24.26 and it occurs in the pipe between nodes 19 and 64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 5 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ""*"* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 19.50 1.049 E 2.0 1.500 12.125 K Factor=5.60 to 120.0 0.0 2.000 4.981 EQ01 19.5 0.1243 0.0 3.500 0.435 Vel = 7.24 0.0 19.50 17.541 K Factor= 4.66 D002 19.50 1.049 T 5.0 1.500 12.125 K Factor=5.60 to 120.0 0.0 5.000 4.981 EQ02 19.5 0.1242 0.0 6.500 0.807 Vel= 7.24 0.0 19.50 17.913 K Factor= 4.61 4C 22.01 1.049 T 5.0 5.420 22.347 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 60 22.01 0.1553 0.0 10.420 1.618 Vel = 8.17 0.0 22.01 23.965 K Factor= 4.50 4F 22.06 1.049 T 5.0 5.420 22.442 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 61 22.06 0.1560 0.0 10.420 1.625 Vel = 8.19 0.0 22.06 24.067 K Factor= 4.50 41 22.26 1.049 T 5.0 5.420 22.866 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 62 22.26 0.1587 0.0 10.420 1.654 Vel = 8.26 0.0 22.26 24.520 K Factor= 4.50 4L 22.62 1.049 T 5.0 5.420 23.601 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 63 22.62 0.1633 0.0 10.420 1.702 Vel = 8.40 0.0 22.62 25.303 K Factor= 4.50 4M 21.34 1.049 T 5.0 5.750 21.005 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 18 21.34 0.1467 0.0 10.750 1.577 Vel = 7.92 0.0 21.34 22.582 K Factor= 4.49 4N 22.00 1.049 T 5.0 5.750 22.332 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 19 22.0 0.1552 0.0 10.750 1.668 Vel = 8.17 0.0 22.00 24.000 K Factor= 4.49 40 22.00 1.049 T 5.0 5.750 22.332 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 19 22.0 0.1552 0.0 10.750 1.668 Vel = 8.17 0.0 22.00 24.000 K Factor= 4.49 4A 19.50 1.049 0.0 11.330 17.541 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 4B 19.5 0.1242 0.0 11.330 1.407 Vel = 7.24 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 6 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """" Notes *" Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 4B 20.06 1.049 T 5.0 5.920 18.948 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 60 39.56 0.4594 0.0 10.920 5.017 Vel = 14.69 0.0 39.56 23.965 K Factor= 8.08 4D 19.54 1.049 0.0 11.330 17.617 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 4E 19.54 0.1246 0.0 11.330 1.412 Vel = 7.25 4E 20.10 1.049 T 5.0 5.920 19.029 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 61 39.64 0.4614 0.0 10.920 5.038 Vel = 14.72 0.0 39.64 24.067 K Factor= 8.08 4G 19.73 1.049 0.0 11.330 17.955 K Factor @ node EQ01 to , 120.0 0.0 0.0 0.0 4H 19.73 0.1269 0.0 11.330 1.438 Vel = 7.32 4H 2O.29 1.049 T 5.0 5.920 19.393 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 62 40.02 0.4695 0.0 10.920 5.127 Vel = 14.86 0.0 40.02 24.520 K Factor= 8.08 4J 20.05 1.049 0.0 11.330 18.541 K Factor @ node EQ01 to 120.0 0.0 0.0 0.0 4K 20.05 0.1307 0.0 11.330 1.481 Vel = 7.44 4K 20.61 ' 1.049 T 5.0 5.920 20.022 K Factor @ node EQ02 to 120.0 0.0 5.000 0.0 63 40.66 0.4836 0.0 10.920 5.281 Vel = 15.09 0.0 40.66 25.303 K Factor= 8.08 18 21.34 1.049 0.0 9.670 22.582 to 120.0 0.0 0.0 0.0 19 21.34 0.1466 0.0 9.670 1.418 Vel = 7.92 19 44.00 1.049 T 5.0 3.580 24.000 to 120.0 0.0 5.000 0.0 64 65.34 1.1632 0.0 8.580 9.980 Vel = 24.26 0.0 65.34 33.980 K Factor= 11.21 60 61.56 2.635 0.0 8.670 23.965 to 120.0 0.0 0.0 0.0 61 61.56 0.0118 0.0 8.670 0.102 Vel = 3.62 61 61.70 2.635 0.0 10.670 24.067 to 120.0 0.0 0.0 0.0 62 123.26 0.0425 0.0 10.670 0.453 Vel = 7.25 62 62.28 2.635 0.0 8.670 24.520 to 120.0 0.0 0.0 0.0 63 185.54 0.0903 0.0 8.670 0.783 Vel = 10.92 63 63.29 2.635 3E 24.711 24.580 25.303 to 120.0 0.0 24.711 1.009 64 248.83 0.1556 0.0 49.291 7.668 Vel = 14.64 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 3 a Final Calculations - Hazen-Williams Beneficial Fire Protection Page 7 FMC ZEPHYRHILLS EAST PORTE COCHERE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv *'"''*' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 64 65.34 4.26 5E 65.835 114.000 33.980 to 120.0 0.0 65.835 1.299 65 314.17 0.0231 0.0 179.835 4.150 Vel = 7.07 0.0 314.17 39.429 K Factor= 50.03 65 314.17 4.26 2E 26.334 15.500 39.429 to 120.0 0.0 26.334 0.0 DTOR 314.17 0.0231 0.0 41.834 0.965 Vol = 7.07 0.0 314.17 40.394 K Factor= 49.43 DTOR 314.17 4.26 E 13.167 9.170 40.394 to 120.0 B 15.8 92.169 3.972 DBOR 314.17 0.0231 D 36.868 101.339 2.339 Vel = 7.07 T 26.334 DBOR 0.0 4.31 E 13.937 6.000 46.705 to 120.0 0.0 13.937 2.599 BOR 314.17 0.0218 0.0 19.937 0.434 Vel = 6.91 0.0 314.17 49.738 K Factor= 44.55 BOR 314.17 6.09 3E 64.749 251.000 49.738 to 150.0 2F 21.583 86.332 -2.599 BFD 314.17 0.0027 0.0 337.332 0.904 Vel = 3.46 BFD 0.0 6.09 Zid 0.0 6.000 48.043 to 150.0 E 21.583 21.583 5.466 Fixed Loss =2.867 BFS 314.17 0.0027 0.0 27.583 0.074 Vel = 3.46 BFS 0.0 6.09 E 21.583 14.000 53.583 to 150.0 G 4.625 72.457 -1.299 SRCE 314.17 0.0027 T 46.249 86.457 0.231 Vel = 3.46 250.00 Qa= 250.00 564.17 52.515 K Factor= 77.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Beneficial Fire Protection Page 1 FMC ZEPHYRHILLS 1 ST FLOOR REMOTE Date 070518 Hydraulic Design Information Sheet Name -- Florida Medical Clinic Date - 7-5-18 Location - 36757 Eiland Blvd. Zephyrhills, Florida Building - System No. - Contractor - Beneficial Fire Contract No. - Calculated By - SG Drawing No. - FP2 Construction: ( ) Combustible (X) Non-Combustible Ceiling Height - 9'-0" Occupancy - Light Hazard-- Offices S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. y ( ) NFPA 231 ( ) NFPA 231C (X) Figure 11.2.3.2.3.1 Curve Qr Head Red S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 959 SF System Type Sprinkler/Nozzle Density - .10 (X) Wet Make Globe D Area Per Sprinkler - 225 ( ) Dry Model GL5601 E Elevation at Highest Outlet - 11.500 ( ) Deluge Size 1/2 S Hose Allowance - Inside - ( ) Preaction K-Factor 5.6 I Rack Sprinkler Allowance - ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 339.27 Press Required - 53.30 Riser Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 9-20-17 Cap. - T Time of Test - Rated Cap.- Elev.- E Static Press - 70 @ Press - R Residual Press - 50 Elev. - Well Flow - 993 Proof Flow S Elevation - 0 U P Location - Eiland Blvd. 450 feet east of Simons Rd. P L Source of Information - City of Zephyrhills Utilities y C Commodity Class Location O Storage Ht. Area Aisle W. M Storage Method: Solid Piled a Palletized o Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: -- LANNCO,ir!C. _ _ 'is J ENGINEERING U-73ULTING REVIEW DATE O "'�' CERTIFICATE OF AU'y NORVATION _ CITY OF ZEPHYRHILLS FIRE AND LIFE SAFETY EXAMINER P.O.BOX 41431 ST.PETERSBURG ALL WORK SHALL COMPLY WITH FLORIDA FRA 3743 � K J ` NKB -ill NFFA CODES AND STANDARDS (727)345.8556 FLORIDA,,p.E:a47!)2 -=- Water Supply Curve C . Beneficial Fire Protection Page 2 FMC ZEPHYRHILLS 1 ST FLOOR REMOTE Date 070518 City Water Supply: Demand: Cl -Static Pressure : 70 D1 - Elevation 4.981 C2- Residual Pressure: 50 D2-System Flow :239.272 C2- Residual Flow 993 D2-System Pressure 53.309 Hose ( Demand) : 100 D3- System Demand :339.272 Safety Margin 13.948 150 140 130 P 120 R 110 E 100 S 90 S 80 C1 U 70 R 60 D 2 E 50 D3 40 30 20 10 100 200 300 400 500 600 700 800 900 FLOWN ^ 1.85) Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Fittings Used Summary Beneficial Fire Protection Page 3 FMC ZEPHYRHILLS 1ST FLOOR REMOTE Date 070518 Fitting Legend Abbrev. Name 1/2 3/4 1 11/4 11/2 2 21/2 3 31/2 4 5 6 8 10 12 14 16 18 20 24 B Generic Butterfly Valve 0 0 0 0 0 0 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E 90'Standard Elbow 2 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 F 45'Elbow 1 1 1 1 2 2 3 3 3 4 5 7 9 11 13 17 19 21 24 28 G Generic Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 S Generic Swing Check Valve 4 5 5 7 9 11 14 16 19 22 27 32 45 55 65 76 87 98 109 130 T 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zid Wilkins 350DA Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD Beneficial Fire Protection Page 4 FMC ZEPHYRHILLS 1 ST FLOOR REMOTE Date 070518 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. D001 11.5 5.6 16.14 na 22.5 0.1 225 7.0 D002 11.5 5.6 16.14 na 22.5 0.1 225 7.0 1 B 11.5 K=K @ EQ01 24.58 na 23.86 1 D 11.5 K=K @ E001 21.85 na 22.5 1 H 11.5 K=K @ EQ01 25.11 na 24.12 11 11.5 K=K @ EQ01 27.01 na 25.02 1 A 11.5 K=K @ EQ02 25.33 na 23.96 10 11.5 25.66 na 1 C 11.5 K=K @ EQ02 26.81 na 24.65 11 11.5 22.8 na 1 E 11.5 K=K @ EQ02 23.03 na 22.84 1 F 11.5 K=K @ EQ02 24.13 na 23.39 1 G 11.5 K=K @ EQ02 25.99 na 24.27 12 11.5 26.63 na 11 11.5 K=K @ EQ02 26.83 na 24.66 13 11.5 28.14 na 40 11.5 31.93 na 41 11.5 32.02 na 42 11.5 32.58 na 43 11.5 42.65 na TOR 11.5 43.82 na BOR -3.0 51.1 na BFD 3.0 49.04 na BFS -3.0 54.47 na SRCE 0.0 53.31 na 100.0 The maximum velocity is 16.1 and it occurs in the pipe between nodes 1 G and 41 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 5 FMC ZEPHYRHILLS 1 ST FLOOR REMOTE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv """""* Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn D001 22.50 1.049 E 2.0 2.500 16.143 K Factor=5.60 to 120.0 0.0 2.000 4.981 EQ01 22.5 0.1618 0.0 4.500 0.728 Vel = 8.35 0.0 22.50 21.852 K Factor= 4.81 D002 22.50 1.049 T 5.0 2.500 16.143 K Factor=5.60 to 120.0 0.0 5.000 4.981 EQ02 22.5 0.1617 0.0 7.500 1.213 Vel = 8.35 0.0 22.50 22.337 K Factor= 4.76 1 B 23.86 1.049 T 5.0 1.000 24.581 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 10 23.86 0.1805 0.0 6.000 1.083 Vel = 8.86 0.0 23.86 25.664 K Factor= 4.71 1 D 22.50 1.049 T 5.0 0.875 21.852 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 11 22.5 0.1619 0.0 5.875 0.951 Vel = 8.35 0.0 22.50 22.803 K Factor= 4.71 1 H 24.12 1.049 T 5.0 3.250 25.113 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 12 24.12 0.1841 0.0 8.250 1.519 Vel = 8.95 0.0 24.12 26.632 K Factor= 4.67 1 J 25.02 1.049 T 5.0 0.750 27.012 K Factor @ node EQ01 to 120.0 0.0 5.000 0.0 13 25.02 0.1969 0.0 5.750 1.132 Vel = 9.29 0.0 25.02 28.144 K Factor= 4.72 1 A 23.96 1.536 0.0 11.670 25.332 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 10 23.96 0.0284 0.0 11.670 0.332 Vel = 4.15 10 23.86 1.536 0.0 11.210 25.664 to 120.0 0.0 0.0 0.0 1 C 47.82 0.1019 0.0 11.210 1.142 Vel = 8.28 1 C 24.65 1.536 T 10.108 13.170 26.806 K Factor @ node EQ02 to 120.0 0.0 10.108 0.0 40 72.47 0.2199 0.0 23.278 5.119 Vel = 12.55 0.0 72.47 31.925 K Factor= 12.83 11 22.50 1.536 0.0 8.830 22.803 to 120.0 0.0 0.0 0.0 1 E 22.5 0.0253 0.0 8.830 0.223 Vel = 3.90 1 E 22.84 1.536 0.0 12.000 23.026 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 1 F 45.34 0.0923 0.0 12.000 1.108 Vel = 7.85 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 i Final Calculations - Hazen-Williams Beneficial Fire Protection Page 6 FMC ZEPHYRHILLS 1 ST FLOOR REMOTE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv "'**'"' Notes Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 F 23.39 1.536 0.0 9.330 24.134 K Factor @ node EQ02 to 120.0 0.0 0.0 0.0 1 G 68.73 0.1994 0.0 9.330 1.860 Vel = 11.90 1 G 24.27 1.536 T 10.108 7.170 25.994 K Factor @ node EQ02 to 120.0 0.0 10.108 0.0 41 93.0 0.3489 0.0 17.278 6.028 Vel = 16.10 0.0 93.00 32.022 K Factor= 16.43 12 24.12 1.536 0.0 6.920 26.632 to 120.0 0.0 0.0 0.0 11 24.12 0.0286 0.0 6.920 0.198 Vel = 4.18 11 24.66 1.536 0.0 12.420 26.830 K Factor Qa node EQ02 to 120.0 0.0 0.0 0.0 13 48.78 0.1058 0.0 12.420 1.314 Vel = 8.45 13 25.02 1.536 T 10.108 9.420 28.144 to 120.0 0.0 10.108 0.0 42 73.8 0.2274 0.0 19.528 4.440 Vel = 12.78 0.0 73.80 32.584 K Factor= 12.93 40 72.47 2.703 0.0 6.875 31.925 to 120.0 0.0 0.0 0.0 41 72.47 0.0141 0.0 6.875 0.097 Vel = 4.05 41 93.01 2.703 0.0 8.705 32.022 to 120.0 0.0 0.0 0.0 42 165.48 0.0646 0.0 8.705 0.562 Vel = 9.25 42 73.79 2.703 T 18.651 60.125 32.584 to 120.0 0.0 18.651 0.0 43 239.27 0.1278 0.0 78.776 10.067 Vel = 13.38 43 0.0 4.31 3E 41.811 46.790 42.651 to 120.0 0.0 41.811 0.0 TOR 239.27 0.0132 0.0 88.601 1.167 Vel = 5.26 0.0 239.27 43.818 K Factor= 36.15 TOR 239.27 4.31 E 13.937 14.500 43.818 to 120.0 B 16.724 61.322 6.280 BOR 239.27 0.0132 S 30.661 75.822 0.999 Vel = 5.26 0.0 239.27 51.097 K Factor= 33.47 BOR 239.27 6.09 3E 64.749 251.000 51.097 to 150.0 2F 21.583 86.332 -2.599 BFD 239.27 0.0016 0.0 337.332 0.547 Vel = 2.64 BFD 0.0 6.09 Zid 0.0 6.000 49.045 to 150.0 E 21.583 21.583 5.379 ' " Fixed Loss=2.78 BFS 239.27 0.0016 0.0 27.583 0.044 Vel = 2.64 BFS 0.0 6.09 E 21.583 14.000 54.468 to 150.0 G 4.625 72.457 -1.299 SRCE 239.27 0.0016 T 46.249 86.457 0.140 Vel = 2.64 100.00 Qa= 100.00 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen-Williams Beneficial Fire Protection Page 7 FMC ZEPHYRHILLS 1 ST FLOOR REMOTE Date 070518 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 339.27 53.309 K Factor= 46.47 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087