HomeMy WebLinkAbout18-20102 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20102
FIRE SPRINKLER SYSTEM PERMIT
PERMIT INFORMATION_.'___ _ -=-LOCATION INFORMATION
Permit Number: 20102 Address: 7306 GALL BLVD
Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. ;f
Class of Work: FIRE-SPRINKLER SYS Township: Range: Book:
Proposed Use: COMMERCIAL Lot(s): Block: Section.
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 35-25-21-0010-08800-0000
Improv. Cost: 2,487.00 OWNER INFORMATION
Date Issued: 8/16/2018 Name: BEAR STEARNS COMMERCIALMORTGA E
Total Fees: 175.00 Address: 5221 N O CONNOR BLVD STE 600
Amount Paid: 175.00 IRVING TX 75039-4414
Date Paid: 8/16/2018 Phone:
Work Desc: INSTALLATION FIRE SPRINKLER SYSTEM-
CONTRACTOR(S) APPLICATION FEES
ROSE FIRE PROTECTION FIRE SPRINKLER SYS 50.00 FIRE INSPECTION FEES 45.00
FIRE PLAN REVIEW FEES 50.00 CONTRACTOR CERTIFICATE 30.00
5 �
Ins actions Required
FIRE-PRESSURE TEST
FIRE ACCEPTANCE Final
Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire
prevention and protection related activities-such as inspections, plan review,administrative fees,and other
costs related to the aforementioned.
Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of
the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final
inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All
work shall be performed in accordance with City Codes and Ordinances.
"WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF
COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN
FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE
RECORDING YOUR NOTICE OF COMMEN ENT."
/�,--Zzz, I I I I
ONT CTOR SIGNATURE PERMIT OFFICE
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED
ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041
,(tpftl4fl'
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: /7-
U
Site:
Permit Type:
Approved w/no comments:Lot Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Gene Brawn—Fire Safety Officer Date Contractor and/or Homeowner
(Required when comments are present)
\ / Sales
Designs
Installations
\\ SENILE
FI EI�OtE�Ct1011 Inspection
PROPOSAL
Submitted To: Work to be performed at:
Name: Fudin Construction LLC Proposed Restaurant
Street: 2530 NE 4611 Avenue 7306 Gall Blvd
City: Ocala Zephyrhills, Florida 33541
State: Florida
Phone: 352-208-7879
Fax:
Attn: Li Wen
Email: wenhlee2005@yahoo.com
We propose to furnish labor and materials for the installation of:
Modifications to the existing fire sprinkler system to provide protection for the new interior
alterations per NFPA-13 2013 and local codes.
1. All new chrome pendent fire sprinklers to match the existing
2. Fire sprinklers will not be centered in the ceiling tiles
3. Price includes fire sprinkler shop drawings, and permit fees required by the fire Marshall's
office.
4. All work and material to be in accordance with NFPA-13 2013and local codes.
5. Restaurant seating area fire sprinklers to be spaced per light hazard, kitchen area fire
sprinklers to be spaced per ordinary hazard,two New Dry pendent fire sprinklers to be
installed in freezer and coolers
Our base price for this work will be: $2,487.00
(No final inspection will be scheduled unless final payment is received)
Exclusions from our work will be: alarm system, no shut down fees are included for the fire
sprinkler system (if required by the property manager ) electrical connections, painting,fire
extinguishers, relocation/raising of existing branch lines and or mains to accommodate other
trades.
Submi y, Accepted By:
Signature:
902 Carter Rd.,Suite 240 Winter Garden, FL 34787 Ph:407.347.5976 Fax:407.347.5978
813-780-0020 City of Zephyrhills Fire Fax-813-780-0021
FQ Permit Application
Date Received P Phone Contact for Permit D 25 S
Owner's Name </ ti D �L 1 �+ Owner's Phone Number E= r
Owner's Address
Fee Simple Titleholder Name Titleholder Phone Number
Fee Simple Titleholder Address 2 / (�
Job Address ✓6 �j l' �} L�- �✓I V Lot#
Sub Division C
/� I l Parcel# agoC�- (Jo /y
G 1 h
.. - ., •133AID1ED.:E,�011ti_ef3° . _ ,< .� E, _ „ ,.
Bio-Hazard Waste Storage-ANNUAL Fumigation Tent
Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL
Controlled Bum Hood Installation
Emergency Generator<30 kw LP/Natural Gas-Installatior
Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale
0 Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL
Qtrl Semi Anl Other
Sprinkler El ❑ ❑ ❑ Recreational Bum
Fire Alarm ❑ ❑ ❑ Sparklers `J
Hood Cleaning El ❑ ❑ ❑ n Sprinkler System Installations
Hood Suppression ❑ ❑ ❑ Standpipes(Sprinkler Sys)
Fire Alarm Installation Torch Roofing/Tar Kettle
Fire Pumps Waste Tire Storage ANNUAL
eFlammable Application-ANNUAL I LIEU Valuation of Project
Fuel Tanks
Q Other:
Contractor Company
Signature Registered Y/N Fee Current I Y/N
Address 0 2 5/ 5-1 Ir yp IAI In 6&� L License# Y oUo n6
ELECTRICIAN �( 167 Company
Signature Registered Y/N Fee Current Y/N
Address License#
PLUMBER Company
Signature Registered Y/N Fee Current Y/N
Address License#
MECHANICAL[-------7— Company
Signature Registered Y/N Fee Current Y/N
Address F License#
OTHER Company
Signature Registered Y/N Fee Current Y/N
Address License#
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner)
If over$2500,a Notice of Commencement is required(Mechanical work over$5000)
Supply two(2)sets of drawings with applicable documentation
Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com)
I '
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more_restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and
that all work will be done in compliance with all applicable laws regulating construction, zoning and land
development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify
that no work or installation has commenced prior to issuance of a permit and that all work will be performed to
meet standards of all laws regulating construction, County and City codes, zoning regulations, and land
development regulations in the jurisdiction. I also certify that I understand that the regulations of other
government agencies may apply to the intended work, and that it is my responsibility to identify what actions I
must take to be in compliance.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTE O OBTAIN FINANCING, CONSULT
WITH YOUR-LENDER O A RNEY BEFORE RECORDING YOUR NOTICE ENCEMENT
FLORIDA JURAT(F.S.117 )
OWNER OR AGENT At CONTRACTOR
ubscnbed and sw or affirmed) fore me his Subscribed and sworn to(or affirmed before me this
4 ��by U� �. R6�— -s by �uu�
ho /are rson illy know Ao me or has/have produced Who is/ar sonally know to me or has/have produced
as identification. as identification.
Notary Public �1! ri ` ` —Notary Public
Commission No.G.C7 a Commission No. l2 a 02 1G
Lr (V�_A Con k,t k.
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
Cori Holton
Cori Holton NOTARY PUBLIC
_ NOTARY PUBLIC STATE OF FLORIDA
c STATE OF FLORIDA `�?Comm#GG210257
?Comm*GG210257 •N E 19�� Expires 4/23/2022
•�Nc 1.1b Expires 4/23/2022
Bulletin 157 Rev.I
R M.odel F30R
Quick Response
1 ble
Dry Sprinklers
Features
1. The Model F3QR sprinkler utilizes Belleville Spring
Closure Technology. Reliable is the first in the industry
to produce a Quick Response Dry Concealed sprin-
kler utilizing this technology.
2. Styles available
R
• Pendent
ko)
• Recessed FP Pend t
• Recessed F1
A
• Conceale 'S o Pendent Pendent HB
• Hod (See Fig. 1) (See Fig.2)
• i iz
zontal Sidewall
• R 1 Horizontal Sidewall
3. 11/2"(38 escutcheon adjustment on pendent sprinkler.
4. Y2" (13mm) escutcheon adjustment on recessed sprin-
kler with push-on/thread-off FP Model Escutcheon ring.
5. 3/8" (9.5mm) cover plate adjustment on c V,ca
sprinkler with push-on/thread-off CCP Cov
6. 3/4" (19mm) escutcheon adjustmp
'fV sed
sprinkler with F1 Escutcheon 0
7. Attractive appearance. frangible glass Aecessed FP Pendent Concealed
bulb and galvanized nip (See Fig.3) (See Fig.4)
8. Lengths available to accommodate installation di-
mensions from 2" -to- 48" (51 mm -to- 1219mm), in
1/4" (6mm) increments. See specific styles for correct
'A" dimension range. 00,
9, Available in a variety of plated and painted finishes.
10.Polyester Coated Corrosion Resistant Sprinklers.
US Patent Numbers 5,775,431 and 5,967,240.
Other US Patents pending.
Approvals Recessed F1 Pendent Horizontal Si Zij_
1. Listed by Underwriters Laboratories Inc. and UL (See Fig.5) (See Fig.6)
Certified for Canada (cULus)
Style Response System Sprin kle Ty r pe Hazard
Pendent
Recessed Pendent Wet Pipe Light
Recessed F1 Pendent Quick Dry Pipe Ordinary
CCP Concealed All Preaction
I' riz
Horizontal Sidewall Wet Pipe Horizontal Sidewall
Recessed Horizontal Sidewall Quick Dry Pipe Light (See Fig.7) -.00
(R5734) All Preaction
2. Certified by—FM Approvals
Style Response Sprinkler
System Type Hazard
Light
Pendent Wet Pipe
Recessed F1 Pendent Quick Dry Pipe Ordinary, t'
(R5714) All Preaction Groups
1&2
Horizontal Sidewall Wet Pi Recesse Recesses
Quick Dry Pipe � Light Horizo idewall
Recessed F1 Horizontal Sidewall �ip Horizontal Sidewal
(R5734) All Preaction ee Fig.8) (See Fig.9)
3. NYC; MEA 25-8-93-E —
The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
1
Model F30R Dry Pendent Sprinkler Model F30R Dry Pendent w/HB Escutcheon
"A"Dim. 1 2"to 48"(51mm to 1219mm)in 1/4"(6mm)increments "A"Dim. 31/2"to 48" 89mm to 1219mm in 1/4" 6mm increments
Finishes"] Standard Temperature Ratings
Sprinkler Escutcheon Sprinkler Max.
Bronze Brass(3) Classification Temperature Ambient Bulb Color
Chrome Plated Chrome Plated RatingTemp.
White Pol ester(2) White Ordinary 135°F (57°C) 100°F (38°C) Orange
(1)Other finishes and colors are available on special order. Ordinary 155°F (68°C) 100°F (38°C) Red
Consult factory for details. Intermediate[7] 175°F (79°C) 150°F (66°C) Yellow
(2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate 200°F (93°C) 150°F (66°C) Green
White, High(1) 286°F 141°C 225°F 107°C Blue
(3)Not available for HB escutcheons. Sprinkler can and escutcheon fabricated of brass for better weather
resistance in exterior applications.
_ ___ ______ (1)Listed and Certified only by cULus.
--Eli#--f------I--��k---�
r_ r
u t�System Tee �=j
i"NPT — System Tee
DIG. �
A'Dimension le i Cm]
Hole n Ce7ng i'NF[
-1/4 [- Range 'A'Dimension DIe Hole6+n�Ceii'�[n
-1/4"[-5.4mm] 1 43/64°Dio. Adjustment Ronge g //_
+1 1/4"[+31.6mm] [42.5mm] 1 1/2'[38.1mm] +,%2'[+127mm] Eseuth2 Din.
Total Adjustment eO
Sprinkler Co.
Ceiling t 1j4'[31.8mm] C 7mm]
Escuthean Adj.
1/4'[6.4mm] t
1' 26.4
Escutcheon Escutcheon [ ]
Ceiling ei m Adjustment Escu Total Ad].
1/2'[1'72
m1
Escutheon Adj.
Sprin Nominal Position
of Escutcheon
Nominal Position
of Escutcheon [4t.3mm1
Nominal Pmiruston [41/8'
1/4"[6.4mm]
Protrusion 3'Dio.
[76.2mm] NEM'157RiVf
2 13j84'[56.88mm] NEly/57FIX12
Fig. 1 Dla.
Note: The sprinkler can protrudes 114"when escutcheon is in nominal Fig.2
position. Escutcheon adjustment provides 114"(-6mm)to +11/4" Note: The sprinkler can protrudes 1114"when escutcheon is in nomi-
(+32mm)"A"dimension adjustment range. nal position. Escutcheon adjustment provides-1/2"(-12.7mm)to
+1112"(+12.7mm)"A"dimension adjustment range.
Sprinkler Guard: Modes C-2
Sprinkler Installation Wrench: Model F3 Sprinkler Wrench
Sprinkler Identification Number(SIN): R5714
Model F30R Dry Recessed FP Pendent Sprinkler
"A"Dim. 31b"to 48" 89mm to 1219mm in 1/4" 6mm increments �___- ----- ----- _
Finishes(') I - --;'--- ----r-- -�I
-III--I—Sprinkler Escutcheon _--� __.i Bronze Brass
Chrome Plated Chrome Plated -System Tee
White Poi ester{zj White i"NPT
t11 Other finishes and colors are available on special order. [63 50mma�
Consult factory for details,Cup remainds unfinished. •A" Dimension Hole in Ceiling
Only the escutcheon will contain desired finish. Adjustment Range
(2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or [ts 35mm] 2[se Sam]
White.
Standard Temperature Ratings Nominal Position Sprinkler
of Escutcheon Cup Assembly
Sprinkler Max.
Classification Temperature Ambient Bulb Color Ceiling Escutcheon
Ratin Temp. Ceiling
Ordinary 135°F (57°C) 100°F (38°C) Orange 1/4"[6.35mm]
Ordinary 155-F (68°C) 100°F (38°C) Red Escutcheon Adjustment
Intermediate(1] 175°F (79°C) 150°F (66°C) Yellow 1/4'Escutcheon
[6.35mm] 3 7/32"DIG.
Intermediate 200°F (93°C) 150°F (66°C) Green Escutcheon AdjustmentJL [81J6mm]
s t nHi h(1) 286°F 141°C 5°F 107°C Blue Total Adjustment
N£Xt57FSQT
Sprinkler cup and FP Escutcheon fabricated of steel and recommended Fig.3
for interior applications. Note: Do not install the Model F3OR Dry Recessed FP Pendent Sprin-
a1 Listed and Certified only by cULus. kler in ceilings which have positive pressure in space above.
Sprinkler installation Wrench: Model XL02 Sprinkler Wrench
Sprinkler Identification Number(SIN): R5714
2,
t�
7
Model F3QR Dry Pendent Concealed Sprinkler
"A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments ---- �� r-- ---r
--
"'Finishes`2'CCP Cover Plate -II'�II�I� I {I! -
===�'�'F--3 1---3��===�
Standard Finishes S ecial Application Finishes �r r -- 51�
Chrome Plated Bright Brass Plated System Tee
White Black Plated
Black Paint 1 NPr
Off White 2 1/2" Dia.
[6.35mm]
Satin Chrome "A" Dimension Hole in Ceiling
(1)Utilizes the 1/2"cover plate with 3/8"total adjustment. Adjustment 3/16•ange 2 19/64" Dia.
(2)Other finishes and colors are available on special order. [f4.76mm] [58.34mm]
Consult factory for details.
Nominal Position Sprinkler
of Coverplate Cup Assembly
Standard Temperature Ratings
Coverplate
Sprinkler Cover Plate Max. Ceiling Assembly
Classification Temperature Ambient Ceiling
Temp.Rating
Rating Temp. 3/16• [4.76mm]
Coverplate Adjustment
Ordinary 135°F (57°C) 135°F (57°C) 100°F (38°C) 3/16" [4.76mm]
Ordinary 155°F (68°C) 135°F (57°C) 100°F (38°C) Coverplate Adjustment 3 5/16 Dia.
[84.13mm]
Intermediate(1) 175°F (79°C) 165°F (74°C) 150°F (66°C) 3/8• [9.53mm]
Intermediate 200°F (93°C) 165°F (74°C) 150°F (66°C) Total Adjustment NM57FG04
High(1) 286°F(141°C) 165°F (74°C) 150°F (66°C) Fig.4
Sprinkler cup fabricated of steel and CCP Cover Plate fabricated of Note: Do not install the Model F3QR Dry Concealed Pendent Sprinkler
brass and recommended for interior applications. in ceilings which have positive pressure in the space above.
(1)Listed and Certified only by cULus.
Sprinkler Installation Wrench:
Model XL02 Sprinkler Wrench
Sprinkler Identification Number(SIN): R5714
Model F3QR Dry Recessed F1 Pendent Sprinkler
"A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments
Finishes"' =-- l ---- -_- r--
S rinkler Escutcheon Collar - -
Chrome Plated Chrome Plated Chrome Plated ===a --�
White Polyester(2) White White L 5
System Tee
Other finishes and colors are available on special order.
Consult factory for details. z 1/2• Di.. 1"NPr
(2) cULus Listed as a Corrosion Resistant sprinkler in standard Black or _[63.5omm]
White. Hole in Ceiling
1 15/16"
"A" Dimension [49.2mm]
Standard Temperature Ratings Ad;us}1/4Ronge
Sprinkler Max.
[f6.35mm] 15/16"
Nominal Position Sprinkler [z3.emm
Classification Temperature Ambient Bulb Color of Escutcheon Cup Assembly
Rating Temp.
"
Ordinary 135°F (57°C) 100°F (38°C) Orange Ceiling
Ceiling [31/8.2mm]
Ordinary 155°F (68°C) 100°F (38°C) Red 1/4• [s Adjustment
Intermediate(1) 175°F (79°C) 150°F (66°C) Yellow Escutcheon Adjustment
Intermediate 200oF (93°C) 150°F (66°C) Green 1/4•[6.35]
High(1) 286°F(141°C) 225°F(107°C) Blue Escutcheon Adjustment Escutcheon
1/2" 112.7mm]
Adjustment 2 27/32"[72.2mm] NEW157FGG5
Listed and Certified only by cULus. Fig.5
Sprinkler Installation Wrench:
Model XL02 Sprinkler Wrench
Sprinkler Identification Number(SIN): R5714
3.
Model F30R Dry Horizontal Sidewall Sprinkle Model F30R Dry HSW w/HB Escutcheon
"A"Dim. 1 2"to 48" 51mm to 1219mm in 1/4" 6mm increments I "A"Dim. 31/z"to 48" 89mm to 1219mm in Y4" 6mm increments
Finishes"'
Sprinkler Escutcheon Standard Temperature Ratings
Bronze Brass(3) Sprinkler Max.
Chrome Plated Chrome Plated Classification Temperature Ambient Bulb Color
White Polyester(2) White
Rating Temp.
(1)Other finishes and colors are available on special order. Ordinary 135°F (57OC) 100°F (380C) Orange
Consult factory for details. Ordinary 155-F (680C) 100°F (380C) Red
(2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or Intermediate(1) 175°F (79°C) 150OF (660C) Yellow
White. Intermediate 200OF (93°C) 150-F (660C) Green
(3)Not available for HB escutcheons. High 2860E 141°C 2250E 1070C Blue
1 1/2" [38.10mm] Sprinkler can and escutcheon fabricated of brass for better weather
Totol Adjustment resistance in exterior applications.
Ceiling
Totr[25.4mm]
o al Adjustment
3 4" [101.60mm] Mi Ceiling
1 1/4" [31.75mm] 12" [304.80mm] M r
2 T
Escutcheon Adjustment Escutcheon Adjustment 4"[101.60mm]Min.
System Tee Escutcheon Adjustment 1/2"[127mm] 12"[304.80mm]Max.
1" NPT Escutcheon Adjustment 2 3/32.
2 3/32" system Tee 3 [53.18mm]
[53.18mm] 1'NPT
I II III _
3' _
[76.20mm] [55�88mm] 3-1/2•
Did. m]
Escutcheon Din.
2 1/8• Dia. 3 2 1/2" Dia.
[53.98mml [63.5mm]
Hole 'n Wall 1/4" [6.35mm] Hole in Wall 1-1/4"[31.75mm]Nominal
Sprinkler Can Protrusion p Pro"sion
"A" Dimension
"A"Dimension Escutcheon Can
Adjustment Nominol Position Adjustment Nominal Position
Range - 1/4" [-6.35mm] of Escutcheon Range+ I/2•[+12.7mm] of Escutcheon
-
NEwIs)aros + 1 1/4 [+31.75mm] 1/2"[-12.7mm]
Fig. 6 Fig. 7
Note: The sprinkler can protrudes 1/4"when escutcheon is in nominal Note: The sprinkler can protrudes 11/4"when escutcheon is in nomi-
position. Escutcheon adjustment provides'/4"(-6mm)to +1114" nal position. Escutcheon adjustment provides'/2"(-12.7mm)to
(+32mm)"A"dimension adjustment range. +1/2"(+12.7mm)"A"dimension adjustment range.
(1)Listed and Certified only by cULus.
Sprinkler Installation Wrench: Model F3 Sprinkler Wrench
prinkler Identification Number(SIN): R5734
Model F30R Dry Recessed FP Horizontal Sidewall Sprinkler
"A"Dim. 31/2"to 48"(89mm to 1219mm)in 1/4"(6mm)increments
Finishes"' 3/32
Escutcheon [35.7mm]
Sprinkler Escutcheon 4 [101.6mm]Min.
Bronze Brass System T e Cup 3 12•[304.8mm]M...*
Chrome Plated Chrome Plated NPT
White Polyester(2) White
(1)Other finishes and colors are available on special order. i"`i ,s - --- -- 37/am
Consult factory for details.Cup remainds unfinished."See page 2" _
(2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or 2[632-Di
ml
White. Hole In Wall 3 Nominal
ms ult o^ion
2 19/64•Die. °
[56.3mm] I/4•[6.35]
Standard Temperature Ratings �°`°"h°°°Adj°°"'°°`
'A•Dimension _
Adjustment Range 1/2 .n Adjustment
NEtn37rixV f1/q• Escutcheon Adjustment
Sprinkler Tem- Max. [f6.35mm] 1/4•[6.35]
Classification erature RatingAmbient Temp. Bulb Color Escutchean Adjustment
�+ #'•FOR FACTORY MUTUAL(FM)
Ordinary 135°F (57°C) 100°F (380C) Orange 4--6•FOR UNDERWRITERS LABORATORIES(UC)
Ordinary 155-F (680C) 100-F (38°C) Red Fig.8
Intermediate(1) 175°F (79°C) 1500F (660C) Yellow Notes: Do not install the Model F3QR Dry Recessed FP Horizontal
Intermediate 200oF (93°C) 150°F (66°C) Green Sidewall Sprinkler in walls which have positive pressure in their
High(1) 2860E(141°C) 225oF(1070C) Blue j side space.
• Listed by cULus for Quick Response. Approved by FM for
(1)Listed and Certified only by cULus. Standard Response.
• Recessed Horizontal sidewall sprinklers are listed with cULus
Sprinkler Installation Wrench: for installation of min.4"(100mm)-to-max.6"(150mm)below
Model XL02 Sprinkler Wrench ceiling and approved by FM for installation of min.4"(100mm)
Sprinkler Identification Number(SIN): R5734 -to-max.12"(300mm)below ceiling.
4.
Model F3QR Dry Recessed F1 Horizontal Sidewall Sprinkler
"A"Dim. 31b"to 48"(89mm to 1219mm)in 1/4"(6mm)increments F_ Ceiling —
j�lr---;/B.
O -�
Finishes Escutcheon L.• IJ [3.2mm]
Sprinkler Escutcheon Collar rl System Tee Sprinkler cup 4"[701mm]Min.
Chrome Plated Chrome Plated Chrome Plated
Assembly 3' 12•[0.6 imm]M
White Polyester(2) White White NPT
(1)Other finishes and colors are available on special order.
Consult factory for details. � _-- _ 2 27/32•
°.`. J I [72.2mm]
(2)cULus Listed as a Corrosion Resistant sprinkler in standard Black or
White.
``-�- - 2 1/2" Di...
[63.5mm]
Standard Temperature Ratings Hole in Wall i 3 i
Nominal Position
1 15/16" of Escutcheon
Sprinkler Max. [49.2mm] , 4^ 6.351
Classification Temperature Ambient Bulb Color Escutcheon Adjustment
•A'Dimension 1/2" [12.7mm]
Rating Temp. NEW157FG09 Adjustment Range Adjustment
f1/4
[36.35mm] 1/4"[6.35]
Ordinary 135°F (570C) 100-F (38aC) Orange Escutcheon Adjustment
Ordinary 155-F (68-C) 100-F (380C) Red *• FOR FACTORY MUTUAL
• 4"- 6•FOR UNDERWRITERS LABORATORIES (UL)
Intermediate(1) 1750F (790C) 150OF (66oC) Yellow
Intermediate 200-F (930C) 150-F (660C) Green Fig.9
High(11 286aF(141-C) 225'F(107°C) Blue
• Listed by cULus for Quick Response.Approved by
FM for Standard Response.
(1)Listed and Certified only by cULus. • Recessed Horizontal sidewall sprinklers are listed
Sprinkler Installation Wrench: with cULus for installation of min. 4" (100mm) - to
Model XL02 Sprinkler Wrench -max.6"(150mm)below ceiling and approved by
Sprinkler Identification Number(SIN): R5734 FM for installation of min.4"(100mm)-to-max. 12"
(300mm)below ceiling.
Technical Data: Ordering Information
Orifice Size:1/2"(15mm) Specify:
Thread Size: 1" NPT per ANSI 132.1 1. Sprinkler Type(select one):
Working Pressure: 175 psi(12 bar) (a)Model F3QR Dry Pendent
Nominal K Factor-US/(Metric):5.6/(80) (b)Model F30R Dry Pendent/HB
Product Description (c)Model F3QR Dry Recessed FP Pendent
Reliable ModelF3QRDrySprinklersarequickresponsesprinklers (d)Model F3QR Dry Recessed F1 Pendent
utilizing a durable 3mm frangible glass bulb. This quick response (e)Model F30R Dry Concealed Pendent
enables these sprinklers to apply water to a fire much sooner than (f)Model F3QR Dry Horizontal Sidewall
standard response sprinklers of the similar temperature rating. (g)Model F3QR Dry Horizontal Sidewall/HB
Model F3QR Dry Sprinklers are intended for use in dry and preac- (h)Model F30R Dry Recessed FP Horizontal Sidewall
lion systems and in areas subjected to freezing temperatures,such (i)Model F3QR Dry Recessed F1 Horizontal Sidewall
as freezers and unheated portions inside and outside buildings. 2. Sprinkler Temperature Rating.
Environments wherein dry sprinklers are employed can be cor- 3. Sprinkler Finish.
rosive.For this reason,Model F3 Sprinklers have a special wax fillet 4. Escutcheon type (F1 or FP).
placed in the gap between the cup that supports the bulb and the 5. Cover Plate/Escutcheon Finish.
wrenching boss.This wax will not interfere with the operation of the 6. Length:
sprinkler, and it prevents contaminents from entering the internal "A"Dimension(face of tee to face of ceiling or wall)in
portion of the drop nipple.The wax must not be removed. (6mm)increments.
Operation 7. Model F3QR Dry Pendent (a) is available without
The glass bulb consists of an accurately controlled amount of sprinkler can and escutcheon.
special fluid hermetically sealed inside a precisely manufactured
glass capsule. This glass bulb is specially constructed to provide Note:
fast thermal response. When the temperature increases sufficiently, 1. The "A" dimension is based on a nominally gauged
due to a fire,the bulb shatters allowing operating parts to clear the pipe thread "make-up" of 0.600" (15mm) per ANSI
waterway. This enables the inlet seal to release air or water and 132.1 [71/2 threads approximately].
subsequently, cause water flow over the deflector in a uniform 2. All platings and paintings are decorative and intend-
spray pattern,controlling or extinguishing the fire. ed for interior use.
5.
3
l
General Installation Instructions Maintenance
Model F3QR dry sprinklers must be installed only in stan- The Model F3QR Quick Response Dry Sprinklers should
dard (ANSI B 16.3 class 150 and ANSI B 16.4 class 125) be inspected and the sprinkler system maintained in accor-
pipe tees in the horizontal position,even at branch line ends. dance with NFPA 25. Do not remove the factory applied
They should not be installed into elbows or pipe couplings thermally sensitive wax fillet between the bulb supporting
located on drop nipples to the sprinklers. For these and cup and the wrenching boss. Do not replace this wax with a
other fittings including CPVC", the dry sprinkler should be substitute substance. An Alternate substance may interfere
installed into a fitting to allow protrusion into the fitting in ac- with proper operation of the sprinkler.Do not clean sprinklers
cordance with the diagrams. The "A" dimension of the dry with soap and water, ammonia or any other cleaning fluids.
sprinkler,which extends into the freezers or a freezing zone Remove dust by using a soft brush or gently vacuuming.
from wet pipe systems, should be selected to provide, as a Remove any sprinkler which has been painted (other than
minimum,the specified lengths in inches shown in Fig. 10. factory applied) or damaged in any way. A stock of spare
Caution: sprinklers should be maintained to allow quick replacement
Do not install Model F3QR Dry sprinklers into CPVC of damaged or operated sprinklers. Prior to installation,
adapter fittings or tees that have an internal obstruction. sprinklers should be maintained in the original cartons and
This will damage the sprinkler and/or the fitting. Refer to packaging until used to minimize the potential for damage
Fig. 11. to sprinklers that would cause improper operation or non-
operation.
During installation, the following steps must be followed: Caution:
Use specified by RASCO wrenches only, which are
1. Cut the specified size hole(see illustrations)for the sprin- designed to engage sprinkler's wrenching pad. (Fig. 15,
kler in the ceiling or wall directly in line with the tee. page 9)
2. Apply pipe joint compound to the 1" (25mm) pipe
threads and install sprinkler using the Model F3 or
XLO2 Sprinkler Wrench as specified.
3. Install the Model FP push-on /thread-off escutcheon
or CCP cover plate if required.
Note: Installation of the Model F3QR Sprinklers is not rec-
ommended in copper pipe systems, as this may reduce
the life expectancy of the sprinklers.
Model F3QR Concealed and Recessed In-
stallation Instructions
• The Model XLO2 wrench (Fig. 12) is designed to lo-
cate on the wrenching pads of the recessed sprin-
kler while centering in the cup. A standard '/2" drive
ratchet may be used to drive this wrench. Fig. 13 and
Fig. 14 show sequentially the insertion of the wrench.
First the wrench, with its jaws above the sprinkler de-
flector, is moved laterally until centered with the cup.
Then raise the wrench inside of the cup until its jaws
engage the sprinkler's square wrenching pads (Fig.
14). To remove the wrench, follow this procedure in
reverse order. Care should be taken to avoid striking
the deflector, with the wrench.
• Model F3 Wrench (Fig. 15) is used for installation of
Pendent and Horizontal Sidewall sprinklers.
• Glass bulb sprinklers have orange bulb protectors
to minimize bulb damage during shipping, handling
and installation. REMOVE THIS PROTECTION AT THE
TIME THE SPRINKLER SYSTEM IS PLACED IN SER-
VICE FOR FIRE PROTECTION. Removal of the pro-
tectors before this time may leave the bulb vulnerable
to damage. RASCO wrenches are designed to install
sprinklers when covers are in place. REMOVE PRO-
TECTORS BY UNDOING THE CLASP BY HAND. DO
NOT USE TOOLS TO REMOVE THE PROTECTORS.
6.
RECOMMENDED EXPOSED MINIMUM BARREL LENGTH BASED ON AMBIENT TEMPERATURE IN THE PROTECTED AREA
(STANDARD DRY PENDENT SPRINKLER SHOWN)
INSTALL 1 INCH NPT THREADED
END OF DRY PENDENT SPRINKLER
WET PIPE INTO 7HE 1 INCH NPT SIDE OUTLET
OF A MALLEABLE IRON TEE FRRNG
AMBIENT AMBIENTEXPOSED
�p�N� PER ANSI B 16.3(CLASS 150)
TEMPERATURE OR CAST RON THREADED TEE FRTING
OF PROTECTED 40'F 4C I 50'F 10'C I WF 16'C - III' PER ANSI 16.4(CLASS 125)ONLY.
AREA•DISCHARGE THE EXPOSED MINIMUM BARREL LENGTH-
OF
OF PRINNKLER (FACE OF TEE TO TOP OF CEILING)
IN. IN. YY IN. MY IF HUMIDITY AND TE PEIUTURE DIFFERENTIAL
,WF(4C) 0 0 D CAUSES CONDENSATION ON THE EXPOSED DRY
WF(-1'C) 0 0 0 'f BABARid�IH KWuT WRAPPING INSULATINN EXPOSED
20'17(-TC) 4(101) 0 0 TAPE OR EQUIVALENT.
i
10•F(-120) 6(203) 1 (25.1) D
0'F(-I&C) 12(305) 3(75) 0 MIDO6NEXPOSED (FITTED AREA) I SEAL THE CLEARANCE SPACE
-I OF(-2SC) 14(356) 4(101) 1 (25.1) e I AROUND G THE SPRINKLER TO AVEIM
LEAKAGE OF AIR INTO THE PROTECTED
-2CrF(-2PC) 14(356) 6(152) 3(75) LENGTH
i AREA AND CONSEQUENT FORMATION[IFC13MO SATE AROUND THE FRAME,WHICH
-wF(-3cc) 16(406) 8(203) 4(101) I COULD Bi USE flBIT OPERATION OR CA
-4QF(-40'C) 16(4'S7.) B (203) 4(101) , PREMATURE OPERATIOX SEE BELOW FQ2
RECOMMENDED METH OM
CLEARANCE
-50-F(-49C) 20(508) 10(254) 6(152) BL}ENS1Oi HOLE
-WF(-51-C) 20(508) 10(2 44) 6(152)
•THE PROTECTED AREA REFERS TO THE AREA BELOW THE CEILING.
THE AMBIENT 7EMPERATLRtE IS THE TEMPERATURE AT THE DISCHARGE
END OF THE SPRINKLER.
FOR PROTECTED AREA TEMPERATURES THAT OCCUR BETWEEN THE VALUES R
LISTED.USE THE NEXT COOLER TEMPERATURE
J"THE MIN. REQUIRED BARREL LENGTH IS NOT THE SAME AS THE*9 DIMENSION. CEILING ESIXITCHEDHN
NOTE EXPOSED MINIMUM BARREL LENGTHS ARE INCLUSIVE UP 70 30YPH
WIND VELOCITIES IN THE PROTECTED AREA.
(PROTECTED AREA)
*RECOMMENDED EXPOSED MINIMUM BARREL LENGTHS ALSO APPLY TO HORIZONTAL SIDEWALL DRY SPRINKLERS*
RECOMMENDED DRY SPRINKLER SEAL ARRANGEMENTS
WET PIPE (STANDARD DRY PENDENT SPRINKLER SHOWN) WET PPE
r r
ONEATED AREA)
KOa>(LM CHEATED AREA) NINIMIN
EXPOSED EXPOSED
BARREL R BARREL
LENGTH DECKDTE FLASHING INSIDE FACE I SEAL LENGTH
(SEE RASCO}4003910 (SEE ABOM
(RECOMMENDED)ENDED)
CLEARANCE HOLE
i
i
INSULATED FREIIEIi
i OR COOLER STRUCTURE
OR EXTERIOR FRAMING
i
R
(PROTECTED AREA) DRY SPRINKLER (PROTECTED AREA) DRY SPRINKLER
IN COLD AREA IN COLD AREA
NEW157FG10
Fig. 10
7.
t
*CAUTION*
DO NOT INSTALL MODEL F3, MODEL F3QR OR MODEL DH56 HSW DRY SPRINKLERS INTO
CPVC ADAPTER FITTINGS OR TEES THAT HAVE AN INTERNAL OBSTRUCTION. THIS WILL
DAMAGE THE SPRINKLER AND/OR THE FITTING.
CPVC ADAPTER FITTINGS AND TEES WITH INTERNAL OBSTRUCTIONS ARE ALSO COMMONLY
FOUND DURING THE RETROFITTING PROCESS OF RELIABLE'S OLDER MODEL G3 DRY
SPRINKLERS.
INTERNAL NO
OBSTRUCTION INTERNAL
OBSTRUCTION
FEMALE FEMALE
PIPE PIPE
THREAD THREAD
INCORRECT CORRECT
CPVC ADAPTER CPVC ADAPTER
FITTING OR TEE FITTING OR TEE
1
SHORTER LONGER
INLET INLET F-7-jl-7-
MALE I MALE
PIPE f PIPE f I
THREAD THREAD
-77 -77
MODEL F3-PL,
MODEL F3QR-PL OR STANDARD
MODEL DH56 HSW-PL MODEL F3,
DRY SPRINKLER MODEL F30R OR
MODEL DH56 HSW
DRY SPRINKLER
BE SURE TO ORDER THE CORRECT SPRINKLERS FOR YOUR
APPLICATION
016fgO8A
Fig. 11
8.
a
f
t
Fig. 12-XL02 Wrench Fig. 13-XL02 Wrench Fig. 14-XL02 Wrench
f wR .
Fig. 15-F3 Wrench
9.
i
Reliable. . . For Complete Protection
Reliable offers a wide selection of sprinkler components. Following are some of the many
precision-made Reliable products that guard life and property from fire around the clock.
• Automatic sprinklers • Deluge valves
• Flush automatic sprinklers • Detector check valves
• Recessed automatic sprinklers • Check valves
• Concealed automatic sprinklers • Electrical system
• Adjustable automatic sprinklers • Sprinkler emergency cabinets
• Dry automatic sprinklers • Sprinkler wrenches
• Intermediate level sprinklers • Sprinkler escutcheons and guards
• Open sprinklers • Inspectors test connections
• Spray nozzles • Sight drains
• Alarm valves • Ball drips and drum drips
• Retarding chambers • Control valve seals
• Dry pipe valves • Air maintenance devices
• Accelerators for dry pipe valves • Air compressors
• Mechanical sprinkler alarms • Pressure gauges
• Electrical sprinkler alarm switches • Identification signs
• Water flow detectors • Fire department connection
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory
Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years,and are installed and serviced by the most highly
qualified and reputable sprinkler contractors located throughout the United States,Canada and foreign countries.
Manufactured b
The Reliable Automatic Sprinkler Co.,Inc. Recycled
0 (800)431-1588 Sales Offices Paper
iab
(800)848-6051 Sales Fax Revision lines indicate updated or new data.
Rel le (914)829-2042 Corporate Offices
www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.10/13 P/N 9999970175
Bulletin 131 Rev. M
Model GFR CIO
R
Model GFR Recessed co
e-
n 11abi Quick Response
Sprinklers
Model GFR Sprinkler Types UL Listing Category
Sprinklers, Automatic& Open
Standard Upright Quick Response Sprinkler
Standard Pendent UL Guide Number
Horizontal Sidewall VNIV
HSW1 Deflector Product Description
Intermediate Level Upright Reliable Models GFR and GFR Recessed Sprinklers are
Quick Response fusible solder type automatic sprinklers.
Intermediate Level Pendent These sprinklers have demonstrated response times in
Conventional laboratory tests which are five times faster than standard
response sprinklers.
Model GFR Recessed This quick response enables the Models GFR and GFR
Sprinkler Types Recessed Sprinklers to apply water to a fire much faster
than standard response sprinklers of the same temperature
Recessed Pendent rating.
Recessed Horizontal Sidewall Application
HSW1 Deflector Quick response sprinklers are used in fixed fire protec-
Approvals tion systems: Wet, Dry, Deluge or Preaction. Care must be
1. Underwriters Laboratories, Inc. (UL) exercised that the orifice size, temperature rating, deflec-
2. Underwriters' Laboratories of Canada(ULC) for style and sprinkler spacing are in accordance with the
3. NYC BS&A No. 587-75-SA latest published standards of the National Fire Protection
4. Factory Mutual Approvals(FM) Association or the approving Authority Having Jurisdic-
5 tion. Quick response sprinklers are intended for standard
6. MIL-S-901C and MIL-STD-167-1 area coverage and standard water densities as specified
7. NYC MEA.258-93-E in NFPA 13, Quick response sprinklers and standard re-
sponse sprinklers should not be intermixed.
Upright Pendent Intermediate Level Intermediate Level Small Orifice
Pendent Upright Upright
IL
Conventional Horizontal Sidewall Recessed Recessed Recessed FP
HSW-1 Deflector Horizontal Sidewall Pendent Pendent
NSW-1 Deflector
Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523
C '
Model GFR Quick Response Upright, Pendent & Conventional Sprinklers
Upright Pendent Conventional Small Orifice Upright
Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench
Installation Data:
Nominal K Sprinkler Sprinkler
Sprinkler Type Factor Height Approvals Identification
Numbers SIN
US Metric SSU SSP
Standard-Upright(SSU)and Pendent(SSP)
Deflectors Marked to Indicate Position
1/2'(15mm)Standard Orifice with 1/2"NPT(R1/2)Thread 5.6 80 27/6"(73mm) 1,2,3,6,7 R3125 R3115
7/16'(11mm)Small Orifice with 1/2"NPT(R1/2)Thread(11mm) 4.2 60 27/6"(73mm) 1,2,3,6,7 R3123 R3113
%"(10mm)Small Orifice with 1/2"NPT(R1/2)Thread(10mm) 2.8 40 21/6"(73mm) 1,2,3,7 R3121 R3111
10mm Orifice XLH with R%Thread 4.2 60 73mm ------------- R3124 R3114
17/ "(20mm)Large Orifice with 3/4"NPT(R3/a)Thread 8.0 115 215/1 "(75mm) 1,2,3,4,7 R3127 R3117
Conventional-Install in Upright or Pendent Position
10mm Orifice XLH with R%Thread
15mm Standard Orifice with 1/2"NPT(R1/2)Thread 4.2 60 73mm ------------- R3174
5.6 1 80 1 73mm ------------ R3175
Model GFR Quick Response Upright & Pendent Intermediate Level Sprinklers
4-1/2'Dia. 4-112'Did.
[I 14.3mm] [I 14.3mm]
Locknut To be Assembled
at lnstallatlon To Be Assembled
Spring At Installation
O'Ring
Shield 00 t/a
Shield
3-7/16' 45 e 2-7/8'
[87.3mm] 'E'Ring [73.0mm]
o c
RA CO
Sprinkler Sprinkler
Assembly
i Assembly
131/MU-B I I I1311NM-B
Upright Pendent
Installation Wrench: Model D Sprinkler Wrench Installation Wrench: Model GFR2 Sprinkler Wrench
or Model W2 Sprinkler Wrench
Installation Data:
Nominal K Sprinkler
Sprinkler Type Factor Sprinkler Approvals Identification
P YP Height PP Number SIN
US Metric SSU SSP
Standard Upright(SSU)and Pendent(SSP)
Deflectors Marked to Indicate Position
1/2"(15mm)Standard Orifice with 1/2"NPT(R1/2)Thread 5.6 80 27/6"(73mm) 1,2,3,7 R3195 R3115
"/32"(20mm)Large Orifice with 3/4"NPT(R3/4)Thread 8.0 115 275/ " (75mm) 1,2,3,7 R3197 R3117
NOTE:The protective shield must be assembled in the field per the assembly drawings.
2.
i
Model GFR Quick Response Horizontal Sidewall Sprinkler
Deflector: HSW1
Installation Wrench: Model D Sprinkler Wrench or Model W2 Sprinkler Wrench
Installation Data:
Nominal K Approval Organization Sprinlder
Nominal Factor Sprinkler and T of Approval
Thread Size Identification -
Orifice US Metric Height Light Ordinary Hazard Hazard Number(SIN)
1/2'(15mm) 1/2"NPT(RI/2) 5.6 80 35/16"(84mm) 1,2,3,7 1,2,3,7 R3135 -
7/16"(11mm) 1/2'NPT(RI/2) 4.2 60 35/16"(84mm) 1,2,3,7 — R3133
%"(10mm) 1/2"NPT(R�/2) 2.8 41 35/,fi'(84mm) 1,2,3,7 — R3131
77/ "(20mm) 3/4"NPT(R3/4 8.0 119 35/ "(84mm) 1,2,3,7 — R3137
Model GFR Quick Response Recessed Pendent Sprinklers
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data:
Sprinider Type Nominal K Factor Sprinkler Height Approvals(2) Sprinkler Identification
US Metric Number(SIN)
1/2"(15mm)Standard Orifice with 1/2'NPT(RI/2)Thread 5.6 80 27/e"(73mm) 1,2,3,7 R3115
7/1 fi'(11mm)Small Orifice with 1/2"NPT(R1/2)Thread 4.2 60 27/,"(73mm) 1,2,3,7 R3113
%"(10mm)Small Orifice with 1/2'NPT(R1/2)Thread 2.8 40 27/e'(73mm) 1,2,3,7 R3111
10mm Orifice XLH with R3/,Thread 4.2 60 (73mm) — R3114
77/ "(20mm)Large Orifice with 3/a'NPT(R3/4)Thread 8.0 115 215/,"(75mm) 1,2,3,7 R3117
(1)Refer to escutcheon data table for specific escutcheon approvals and dimensions.
2 114'[57.1mm]Did.
Hole Did. in Ceiling 2 5/6•DK[661
NDLC M LaUNG
1 15116"Did. 2 5/16•DN
Turn Spring Collor [�'l'""'j
P 9 [49.2mmJ cur
Until tight
Against Sprinkler r i1
Wrench Boss
r
1 "1 1 I I r•x 1/2•xmuc
L dr
J
Fare of Fitting 1�
Adjustment(2) 00 da to Ceiling i2j
e Dimension
r
_ J
mull
n F/
1/B• oJsYa r 1/2-[M..1 m]INX.
r cE DF M—
!D F—Of CE2INL
1 518•
[41.Jmm] o
r/a•wus[VUS uax
Fr nruFNr
15/I6•[TSfimmJ
2 27/32'D/A.
1JIRECP-B [72.2mm] _rJr�cr_m
Recessed Pendent/F1 -ssecl Ilenclent
Model GFR Quick Response Recessed Horizontal Sidewall Sprinklers
Deflector: HSW1
Installation Wrench: Model GFR2 Sprinkler Wrench
Installation Data
Approval F o1 Fif6q 1/B
Nominal K APp Wog �[ .•ro 15
Thread Factor Organization(2) Sprinkles ameDslod f�1 [101.6mm m/szsm
Nominal s� Sprinkler T of roval Identification '1 T 9
Orifice NPT Height Light Ordinary Number M G7 °'
--
US Metric Hazard Hazard (SIN) I-T- —
I 15/fe•DK 2 27/J2•Dio.
[722mm]
1/2'(15mm) 1/2"(R7/2) 5.6 81.0 35/,s'(84mm) 1,2,3,7 1,2,3,7 R3135 [492—j
7/,s'(11mm) 1/2"(RI/2) 4.2 61.0 35/16"(84mm) 1,2,3,7 — R3133 �L-Li
3/,"(10mm) 1/2"(R7/2) 2.8 40.6 35/1fi'(84mm) 1,2,3,7 — R3131 --
7/m'(20mm)I 3/4"(R3/4) 8.0 118.2 35/16"(84mm) 1,2,3,7 — R3137
2 I/4"a-
Refer to escutcheon data table for specific escutcheon approvals and dimensions. [572m 1
Hole In Well Cry 2 1/e•
[54.Dmm]
Adjustment(2) I5I/SaI�
3.
w
�
Model GFR & GFR Recessed Quick Response Sprinklers
Unitallatioo Fixishms(,)(2»
Quick response sprinklers are intended for standard area cov- Standard Finishes
emga and standard water densities aospecified in NFR«,13.
Quick response sprinklers and standard response sprinklers Sprinkler Escutcheon
should not bointermixed, Bronze Brass
The Model GFR Recessed Quick Response Sprinkler into be Chrome Plated Chrome Plated
installed asshown. The Model F1cxF2 Escutcheons illustrated Polyester Coated"' Polyester Coated
are the only recessed escutcheons toba used with the Model Special Application Finishes
8FR Pendent cx Horizontal 8idcma||Sprinklers. The use ofany Sprinkler Escutcheon
other recessed escutcheon will void all approvals meaquick Bright Brass Bright Brass
response sprinkler and negate all warranties. Black Plated Black Plated
When installing Model GFR Sprinklers,use the Model DSphn' Satin Chrome Satin Chrome
Wer Wrench or Model VV2 Sprinkler Wrench and when install- "'Other finishes and colors are available,consult factory for details
w/m sprinklers10o" (741C) have black painted solder links and alling�nd�GFRReoaomed8phnNersendpendan\|n�rnn*di�a oprink|om212"�(1'OD"o)have white painted solder links.
| Sprinklers use the Model SFR2 Sprinkler Wrench. Any other w/FM Approved for n3127only.
type of wrench may cause sprinkler damage.
K0aimbemamoe Temperature Ratings
The Models GFR and GFR Recessed Sprinklers should be Sprinkler Mwdmum Ambient
inspected and the sprinkler system maintained inaccordance Classification Rating Temperature
withNRPA 25. Oo not clean the sprinklers with soap and water, OF OC OF oc
ammonia or any other cleaning fluids. Remove any dust using
a soft brush or gentle vacuuming. Remove any sprinkler which
has been painted (other than factory applied)or damaged in
any way. A stock of spare sprinklers should be maintained to al-
low quickxsplaoementofdamagedoropanatedoprinklem. Pri- Escutcheon Data
orto installation,sprinklers should be maintained in the original Face of Fitting To
cartons and packaging until used. This minimizes the potential Escutcheon Approvals Adjustment Ceiling or Wall
for damage resulting inimproper operation ornon~operation. Model Vimension
Ordering Information:
Specify
1. Sprinkler model
2. Sprinkler type "`Approved for Pendent only.
3. Orifice size
4. Temperature rating
5. Sprinkler finish
8. Escutcheon type
7. Escutcheon finish (where applicable)
Note: When Recessed Model GFR/F1 or F2ere ordered,sprinkler and es-
cutcheon mrepookaged separately
Sprinkler Types '
Standard Upright
Standard Pendent
SidemaU
--Horizontal HSVV1 Deflector
Conventional
Recessed
--Pendent
--Horizontal 8idavvaU HGVV 1 Deflector
Intermediate Level
—Uphght
--Pendent
The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory
Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.
Products manufactured and distributed by Reliable have been protecting life and property for over 90 years.
Manufactured by
Reliable Automatic Sprinkler Co.,Inc. Recycled
(800)431'1588 Sales Off ices Paper
Relmlable (800)848-0051 Sales Fax nowown lines indicate updated m new data.
(914)829'2042 Corporate Offices
w�w,o||ub|oaprink|or.onm Internet Address su.Printed mu.aAom,r P/wueoeero024
r
s
Rose Fire Protection
Steel Pipe Submittal
All of the steel pipe to be used on this project meets or exceeds the requirements of one or
more of the following standards as required by paragraph 6.3 NFPA 13-2010:
ASTM A795 Specification for Black and Hot-Dipped Zinc Coated (Galvanized)
Welded and Seamless Steel Pipe for Fire Protection Use
ANSI/ASTM A 53 Specification for Black and Hot-Dipped Zinc Coated (Galvanized)
Welded and Seamless Steel Pipe
ASTM A 135 Specification for Electric — Resistance Welded Steel Pipe
Manufacturers may vary. As per paragraph 6.3.8.1, NFPA 13-2010, all pipe shall be marked
along its length to properly identify its type, schedule and manufacturing standard.
Additional approvals or listings are not required when:
1. Steel pipe meeting the above referenced ASTM specifications is used and joined by welding
or roll-grooved pipe and fittings, the minimum nominal wall thickness for pressures up to 300
psi shall be in accordance with Schedule 10 for sizes up to 6 inches and .188 inches for 8" —
10" pipe.
2. Steel pipe meeting the above referenced ASTM specifications is used and joined by
threaded fittings, the minimum wall thickness shall be in accordance with Schedule 40 in
sizes less than 8 inches for pressures up to 300 psi.
Exception: Pipe meeting the above referenced ASTM specifications with wall thickness and
pressure limitations less than Schedule 40 for threading or Schedule 10 for welding and roll-
grooving, which have been investigated for suitability in automatic sprinkler installations and
listed for this service, shall be permitted when installed in accordance with their UL or FM listing
limitations.
All steel pipe is to be installed in strict accordance with the guidelines of NFPA 13 and therefore
requires no special submittal of specific manufacture's installation instructions as noted in
NFPA 13-2010.
NOTE:
All piping 2" and less shall be Schedule 40.
All piping 2
r
Rose Fire Protection
Threaded and Flanged
Fittings Submittal
All of the threaded or flanged fittings to be used on this project meet or exceed the
requirements of one or more of the following standards as required by paragraph
6.4, NFPA 13-2010:
ANSI B16.4 Cast Iron Fittings Class 125 and 250
ANSI B16.1 Cast Iron Pipe Flanges and Flanged Fittings
ANSI B16.3 Malleable Iron Fittings, Class 150 and 300
Manufacturers may vary.
Fittings are to be installed in strict accordance with the guidelines of NFPA 13 and
therefore require no special submittal of specific manufacture's installation
instructions as noted in NFPA 13-2010.
'i
a
Model-#100
R5-- --
Swivel Loop Hanger - Heavy Duty
APPLICATION:#100 pipe support for stationary piping.
Lowest in-place cost available. Easy adjustment. AIL
�.
NOTE: Meets MSS requirements. O '9
Part No. Pipe H CL IRS MRI A Max. Recom. Finish*
Size Load (lbs.)
1000050EG 1/2 2-3/4 1-1/4 3/8 1 13/16 300 EG
1000050FL 112 2-3/4 1-1/4 3/8 1 13/16 300 FL
1000075EG 3/4 3-1/16 1-7/16 3/8 1 15/16 300 EG
1000075FL 3/4 3-1/16 1-7/16 3/8 1 15/16 300 FL
1000100EG 1 3-5/16 1-9/16 3/8 1 15/16 300 EG
1000100FL 1 3-5/16 1-9/16 3/8 1 15/16 300 FL
1000125EG 1-114 3-9/16 1/5/8 3/8 1 13/16 300 EG
1000125FL 1-1/4 3-9/16 1-5/8 3/8 1 13/16 300 FL
1000150EG 1-1/2 3-13/16 1-3/4 3/8 1 13/16 300 EG
1000150FL 1-1/2 3-13/16 1-3/4 3/8 1 13/16 300 FL
1000200EG 2 4-1/4 1-15/16 3/8 1 13/16 300 EG
1000200FL 2 4-1/4 1-15/16 3/8 1 13/16 300 FL
1000250EG 2-1/2 5-5/8 2-15/16 1/2 1-1/4 1-5/16 1000 EG
1000250FL 2-1/2 5-5/8 2-15/16 1/2 1-1/4 1-5/16 1000 FL
1000300EG 3 6-9/16 3-1/2 1/2 1-1/4 1-7/16 1000 EG
1000300FL 3 6-9/16 3-1/2 1/2 1-1/4 1-7/16 1000 FL
1000350EG 3-1/2 7 3-3/4 1/2 1-1/4 1-11/16 1000 EG
1000350FL 3-1/2 7 3-3/4 1/2 1-1/4 1-11/16 1000 FL
1000400EG 4 7-3/4 4-5/16 5/8 1-5/16 1-3/4 1100 EG
1000400FL 4 7-3/4 4-5/16 5/8 1-5/16 1-3/4 1100 FL
1000500EG 5 9-1/8 4-5/16 5/8 1-5/16 1-13/16 1100 EG
1000600EG 6 10-5/8 5-7/8 3/4 1-9/16 2-1/8 1 1250 EG
1000800EG 8 13-1/8 7-1/16 7/8 1-5/8 2-3/8 1 1250 EG
Conforms With: Federal Specification WW-H-171 (Type 10), Manufacturers Standardization Society
ANSI/MSS-SP-58(Type 10),install in accordance with ANSI/MSS-SP-69.
All dimensions are in inches unless otherwise noted.
`See page 2 for finish and material descriptions.All material is Carbon Steel unless otherwise noted.
Phone: 800-333-0852 a Fax:800-677-5403 49 ����®�
www.erico.com
(DTOLCO' - -------- -www.t01C0.00M
■ 00
. 98 - Rod Stiffener Component of State of
California OSHPD Approved
Seismic Restraints System
Size Ra — Secures 3/8" thru 7/8" hanger rod
Material — on Steel t:?
Function — Secur channel to hanger rod for vertical seismic bracing.
9 9
Approvals — Include ' our Seismic Restraints Catalogapproved
ci
b the State of California O of Statewide Health Plannin and t=;i
Development (OSHPD). For ad nal load s acin and lacement
information relatina to OSHPD ro'ec lease refer to the TOLCO
Seismic Restraint Systems Guidelines
Finish — Electro Galvanized
Note — Available in HDG finish or Stainless Steel m erials.
Order By — Figure number
Fig. 99 - All Thread Rod Cut to Length
Size Range — Secures 3/8" thru 7/8" rod in Dimensions
1" increments od Max.Rec.Load Lbs.
Material — Carbon Steel SI For Service Temps
Maximum Temperature — 750OF 650°F 750°F
Finish — Plain 3/8 0 540
1/2 113 1010
Note — Available in Electro-Galvanized and 5/8 1810 1610
HDG finish or Stainless Steel materials. 3/4 2710 0
Order By — Figure number, rod diameter, rod 7/8 3770 3360
length and finish
Fig. 100 - All Thread Rod Full Lengths
Size Range — Secures 3/8" thru 1 t/2" rod in
10' lengths
Material — Carbon Steel
Maximum Temperature — 750OF
Finish — Plain
Note — Available in Electro-Galvanized and
HDG finish or Stainless Steel materials.
Order By — Figure number, rod diameter
and finish
Dimensions •Weights
Max Rec.Load Lbs.
Rod For Service Temps Approx.
Size 650°F 750OF WtJ100
1/4 240 215 12
3/8 730 540 29
1/2 1350 1010 53
5/8 2160 1610 84
3/4 3230 2420 123
7/8 4480 3360 169
1 5900 4420 222
1 1/4 9500 7140 360
11/2 13800 10370 510
OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330
CUSTOMER SERVICE•800.786.5266
www.tolco.com
Model #300 Maybe mounted T� I]in either position. ��F•i _
Domestic Beam Clamp f
;r
Universal/Reversible (Double Rod Hole)
LIJ
Model #3001 as''�
r.
"Import Beam Clamp TOP BOTTOM
WID
APPLICATION: Structural attachment (with infinite adjustment)to top or bottom
of metal beams, purlins, channel or angle iron to support hanger rod.
NOTE:Set screw must be tightened onto the sloped side of the I-Beam, channel or angle iron flange
and torqued to 60 inch pounds. Set screw and locknut supplied are hardened steel.
Available with a HD finish by special order. For corresponding retainer strap see Models 300C and 30OR
Part No. IRS Max CL D MRI F T Max. Recom. Finish*
Pipe Load (Ibs)
Size Top Bottom
3000037EG 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 EG
3000037PL 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 PL
3000050EG 1/2 8 9/16 1-1/16 11/16 1/2 1/2 950 760 EG
3000050PL 1/2 8 9/16 1-1/16 11/16 1/2 1/2 950 760 PL
3000062EG 5/8 8 9/16 1-1/16 11/16 1/2 112 950 760 EG
3000062PL 5/8 8 9/16 1-1/16 11/16 1/2 1/2 950 760 PL
3000075EG 3/4 8 9/16 1-1/8 13/16 5/8 3/8 950 760 EG
3000075PL 3/4 8 9/16 1-1/8 13/16 5/8 3/8 950 760 PL
3000087EG 7/8 8 9/16 1-1/8 13/16 5/8 3/8 950 760 EG
3000087PL 7/8 8 9/16 1-1/8 13/16 5/8 3/8 950 760 PL
**30010037EG 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 EG
**30010037PL 3/8 4 7/16 1-1/8 1/2 3/8 3/8 500 250 PL
Conforms With: Federal Specification WW-H-171 (Type 23), Manufacturers Standardization Society
SI/MSS-SP-58 (Type 19 & 23), install in accordance with ANSI/MSS-SP-69.
Model 05 Op _„ f`B�
Steel Top Bea lamp m
APPLICATION: For attachment the top of flange of structural H �BS�*_ A
shapes or for use under roof insta 'ons with bar joist type
construction where the thickness of fla does not exceed 5/8". --------
i -
NOTE: Specify Carbon Steel or Stainless Steel �.
�RS� .R
Part IRS A B W H B Max. Recom. Finish* W
No. ad (Ibs.)
3050037PL 3/8 3/4 31/32 1-13/32 1-21/32 3/8 5 PL
305003756 3/8 3/4 31/32 1-13/32 1-21/32 3/8 500 56
3050050PL 1/2 3/4 29/32 1-15/32 1-23/32 3/8 1130 �Sl
3050050S6 1/2 3/4 29/32 1-15/32 1-23/32 318 1130
Conforms With: Manufacturers Standardization Society SP-69(Type 23).
All dimensions are in inches unless otherwise noted.
'See page 2 for finish and material descriptions.All material is Carbon Steel unless otherwise noted.
Phone:800-333-0852 • Fax: 800-677-5403 17 ����0�