HomeMy WebLinkAbout18-20128 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 20128
BUILDING PERMITp
PERMIT-INFORMATION: LOCATION INFORMATION
Permit Number: 20128 Address: MIS SEE DESCRIPTION 6136 FT KING
Permit Type: MISC ZEPHYRHILLS, FL.
Class of Work: RIGHT-OF-WAY Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 03-26-21-0000-00500-0010
Improv. Cost: I . OWNER INFORMATION
Date Issued: 8/ 0/2018. Name: CHARTER COMMUNICATION
Total Fees: l �' Address: 6136 FORT KING RD
Amount Paid: ZEPHYRHILLS FL 33542
Date Paid: Phone:
Work Desc: SEE DESCRIPTION /6136 FORT KING-FEE WAIVED
CONTRACTORS APPLICATION FEES
CHARTER COMMUNICATION
C�U<
Ins ections Required
F OTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application. All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
&_�� � 9�1& , — —&__ &ei(�
CONT OR SIGNATURE PERMIT OFFIgOR
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
CITY OF ZEPHYRIHLLS-BUILDING DEPARTMENT
DATE: RIGHT-OF-NAY USE PERMIT PERMIT" '
No construction under ground or above ground of any facility shall be accomplished on any City Rights of Way without written approval from the
City Building Department.Any application for approval of construction operations on any City owned Rights of Way shall furnish a detailed drawing
shoving the complete scope of the proposed work in triplicate to the office of the Building Official for approval prior to the commencement of any work.A
copy of this permit is to be kept readily available at the site of the work at all times.
PARCEL LD.# 03-26-21-0000-00500-0010 CITY ROAD Fort King
DATE--BTT3Tl8
LOCATION(Legal Description): 6136 Fort King Road,See attached legal description
Permission is hereby granted to Charter Communications or 30432 SR-54 WESLEY CHAPEL,FL 33543
for the construction and maintenance of-
Installation of new cats conduit&cable within road right of way
_subject to the following conditions:
1. The construction and maintenance of such utility shall not interfere with the property and rights of a prior occupant.
2. All work shall be done in keeping with the standards of the City Streets Department and under the supervision of the City Building Official,who
will he notified at least one day prior to commencement of construction.
3. All materials and equipment shall be subject to inspection by the City Building Official.
4. During construction all safety regulations of the Department of Transportation shall be observed and the City shall be relieved of all
responsibility from damage of any nature arising from this permit.Subject to the same terms and conditions,the permit holder may take such safety
measures,including placing and display of caution signs,as it may deem necessary in conduct of construction and maintenance work hereunder. It is the
responsibility of the permittee to????
5. All private and all City properly shall be restored to its original condition as far as practical in the opinion of the City Building Official.
6. All underground crossing installations shall be laid at such depth as maybe specified by the City Building Official.
7. The sketch covering the details of this installation shall be made apart of this permit.This permit is granted with the understanding that the
applicant has notified all other utility users in the area covered by the permit and takes full responsibility for any damage incurred by prior installations as a
result of his operations in order that they may safe guard their interests.
8. It is expressly stipulated that this permit is a license for permissive use only and that the placing or facilities upon public property pursuant to
this permit shall not operate to create or to vest any property right in said holder.
9. Whenever the City decides to further exploit the City Rights of Way,any or all said poles,wires,pipes,cables,or other facilities and
appurtenances authorized hereunder,shall be immediately removed from said Rights of Way,or reset or relocated thereon as required by the City Building
Official at the expense of the holder of this permit.
10.The holder shall save and keep the City harmless from any and all damages,claims,or injuries that may occur by reason of the construction,
maintenance,and operation of said facility.
11.The holder shall complete the requested work within days or this permit shall become null and void.In the event the work
requested is not completed upon the expiration date of this permit,the City shall have the right to complete such work and to charge the holder of the permit
for all costs incurred in completing said work.
12.The holder shall post a cash or surety bond with the City Manager in the sum of S dollars to guarantee performance of the
obligations herein,and to guarantee maintenance of the right-of-way described herein for a period of one(1)year following completion of the requested
installation.In the event a surety bond is posted,the surety bond shall be made payable to the City and shall obligate the surety to hold the City harmless in
the event the holder of this permit should fail to meet any of its obligations hereunder.The bond shall also indemnify the City for all court costs and
reasonable attorneys fees in the event legal action is required to collect on said bond.
SUBMITTED BY:
(Permittee) Charter
Signature&Title � r(y / Construction Coordinator II
Address 30432 SR 54,Wesley Chapel 33543
APPROVED BY:
CITY OF ZEPHYRIIILLS
Building Official
Date:
Utilities Supervisor
Date: -+ ra
Public Works e rt (Js 0AW1 C XG—SW 4a Z)fS
-Meet-
Date: l �-
City Manager
Date
. • Legel Description 1 03-26-21-0000-00500-0010 1 Pasco County Property Appraiser Page 1 of 1
i
Legal Description
03-26-21-0000-00500-0010
Assessed in Section 03, Township 26 South, Range 21 East
of Pasco County, Florida
COM AT SE COR OF SEC TH .N89DG 52' 37"E ALG SOUTH
LINE OF SEC 2 TWP 26S R 21 E 287.96 FT TO SWLY R/W
LINE OF VACATED SCL RR TH N25DG 23' 18"W 903.85
FTALG SAID SWLY R/W LINE FOR POB TH CONT ALG
SAID SWLY R/W LINE N25DG' 23' 18"W 50.85 FT TH
N89DG 53' 27"E 16.59 FT TH N25DG 23' 18"W 110 FT TH
N89DG53' 27"E 149.28 FT TO ,EAST LINE OF SEC TH
SOODG 13' 30"E 99.46 FT ALG EAST LINE OF SEC TH
S64DG 36' 42"W 107.69 FT TO POB SUBJECT TO R/W
EASEMENTPER OR 3142 PG '1794 OVER WLY 5 FT
THEREOF OR 9528 PG 3271
Please`be advised that our legal descriptions are for
assessment purposes only, and are not intended for use in
legal conveyances.
http://search.pascopa.conVparcel-legal.aspx?parcel=2126030000005000010&cache=False 8/2/2018
JOB LOCATION MAP
General Notes
-STADIUM PARK SLEEPY H O L L O' I.AI Catv Construction within the Public Viollits of Way shall be in conformity
Eil—I ON I 1 21 MOBILE M ESTATE with the Local Jurisdiction's"Mlnlmi n Staitda-ds"
E\\��60Nd
LITTLE A 6 R E S ZEPHYR PARK and meet N.E,S,C.,F.L.C.,M.UXLP.and F.P.OS.standards,
Woodland C 2.fhe Contractor shall notify Call Sunshine and other utlltles prior to
ClemeritarySchool F Klu—n.Am
L V E R O A K S E I L A N D PARK S C O T T S D A L E commencement of construction,
VILLAGE T 0 W N H 0 M E S 3,Use the"Pirectlonal Pore Method"for all'Madwa{&drivewa{crossings,
�er.iA.,, "ram rn"accu
GREEN HILLS ptu tiro missle"bores permitted.
Y ' 4.No open asphalt cuts will be permitted wlless pre-approved y
ESTATES -T
+eina+o v u Must.Pcfer to Pasco Canty Open Cut Petal
ZEPHYR RIDGE,'` @ United States s "Pasco Came{Enojincerlriq 5ervlce5 Pesicin 5taidards,Index No.102"
Postal Service 0 A K PAR K
P I N E''(i R 0 V E u nortnavo 5.Al side walk removal and replacement shall be restored to
A D D I T,I 0 N the Local Jurisdiction's and F.P.OS.5Landard 5 ecification No,522
FOREST V I L IL A'S '� �'+ybP ?v y 6.AI aerial construction shall maintain a minimum of 18'clearance parallel to
WEDGEWOOD ,.a. +�
MAN 0 R and crossing all F.P.O,T.,Canty&Municipal Rlcf its of Way
Map data C2018Gao0le I.Must maintain an munmum 3'clearance from Al water&sewer lines,
8.Pepartmant of Public Works,Utilities Inspection Pivislon shall be notified
three M workirlq days prior to commencement of construction.
9.Undercround utilities have been plotted from avalll]le records ad
field o6ervations,but are rot wcessarily exact,ihereforre utility OUIUO K
will be verified IOOft In advance of trenchlrq,plowinq add bo-Inq•
so that cahnairges can be wade III evelit of conflict.
10,Restoration shall begin within three(5)weeks after the installation
of cable/conduit.Full crass by seed and mulch or sodding as approved.
II.No open trenches to be left open overniollit.Needs to be 6ackfilled
or covered.(Public safety Hazzard)
12,No excavation shall be permitted within 10'of protected trees
UTILITY LEGEND (20'for Crand Oaks)•All utility nnstallal ion shall be placed by directional bore
beginnnq outside of protected radius,
x PWR WOOD POLE — — — — — ROW 13.Froslon Control Measures must be used at all times.
EOP 14,these dra+mngs are for permitting purposes only.
PWR CONCRETE POLE —-—-—-—-—-— CENTER LINE 15.Al proposed utllity located within roadside drainage ditches shall be a
151 PWR STEEL POLE — — —- - POWER minfirum of 50"below the lowest•point of the ditch or the invert of ail
)K ST LITE —�f COMM culverts within right of way whichever Is Iowa-.
0 JOINT USE TRANS - -'" - TELEVISION 16,All materials used for bxkfill shall be free from large lumps,clan
® JOINT USE —- -- -- — WATER wood or other extraneous material,FPOr 55 5ection 125-8
f3ackfillinq s1va11 be redone accords nq to FPOf 55 Section 125-
6 FIRE HYDRANT --- -- -- -- SEWER 8,3.1 Ingdralhc method of backfill Is not acceptable.L'Iackflllriq
---- CULVERT ------------- RECLAIM under wet coditions shall conform to FPOr 55 Section 125-8
0 STORM DRAIN ------------- GAS
N APPLICATION CITY OF ZEPHYRHILLS PERMIT PROJECT NAME:6136 FORT KING RD COUNTY:PASCO
Charter - W >�
TO PLACE NEW CONDUIT&CABLE CROSSING COUNTY RIGHT OF WAY DATE:8-13-I8 SECTION:3 TOWNSHIP:26 RANGE:21
® ENGINEER:HELEN FIFE DRAWN BY:K.L.
Ea JOB DESCRIPTION: PRISM NUMBER:807846 NTP 0:207643 SCALE:NONE
h M4f CATV UNDERGROUND CONSTRUCTION TYPE OF PERMIT:CITY TRACKING II: DRAWING SHEET:I OF
PLANVIEW OF CATV UNDERGROUND CONSTRUCTION
a] N
M M
� b
Proposed Placement of
64ft Catv Cable & (1) 2" HOPE Innerduct
1 Directional Bore Minimum 36" Depth
'\ Refer to Directional Bore Profile A
\ End construction
out of R/W
'—..----. .._.. _------'.—..—'.—.. /grass
sw
FORT KING RD 4 Y EOP
—.—'—'-----'-----k------------------------------------------•-------------------- --------C/L3" 8''
—- — 24' — — --
_grass EOP
2
..—._—..—_.—..—..—..—..—.._.._.._..—_---.--._.._..—._—..—..—..—..—. —..—.
Begin construction
\ dw at Pole #2769926
APPLICATION CITY OF ZEPHYRHILLS PERMIT PROJECT NAME:6136 FORT KING RD COUNTY:PASC'O
N®E TO PLACE NEW CONDUIT CABLE CROSSING COUNTY RIGHT OF WAY DATE:8.13-18 SECTION:3 TOWNSHIP:26 RANGE:21
Charter ENGINEER:HELEN FIFE DRAWN BY:K.L.
N' y JOB DESCRIPTION: PRISM NUMBER:807846 NTP k:207643 SCALE:V=50'
iTyeo-wis_aro CATV UNDERGROUND CONSTRUCTION TYPE OF PERMIT:CITY TRACKING @: DRAWING SHEET:2 OF 3
PROFILE VIEW OF CATV UNDERGROUND CONSTRUCTION
PROFILE A
TYPICAL CATV DIRECTIONAL BORE TO PARALLEL ROAD ROW
NORTHWEST ON FORT KING RD
_ ROW BD' Row
'2• Eoo 16' CA 17' Eop 23'
I '
grade 5' sw i II grade
24"----�---------------- --24-------y------------ 40-----------_—_!-__-_24"
6'
30" 23'-----:-tr - --r-- -----------i----- 30"
13'
-- ------ ----------- ------------ --------- -----
36" �------- r----36'.
42 ---------------- -----------I----- ------ ----------------- ----42"
60 ---:----------------- ----------- ----
--------------- ---
i
Proposed Placement of _
64ft Caty Cable &(1) 2" HDPE Inner-duct
Directional Bore Minimum 36" Depth STANDARD TRENCH DETAIL
gal m awn i.pia cmm�cna
s o10r�i�er°oa�roa em As
NOTE: ALL EXISTING UTILITY DEPTHS & LOCATIONS BASED ON A 36-MIN. 2. 3B•MIN.
STANDARD, AVAILABLE RECORDS AND FIELD OBSERVATIONS. a
WILL REQUIRE UNDERGROUND LOCATES PRIOR TO CONSTRUCTION. e
A MINIMUM OF 24" VERTICAL AND 24" HORIZONTAL SEPARATION x•
FROM EXISTING UTILITIES MUST BE OBSERVED.
A MINIMUM OF 16" VERTICAL AND 36" HORIZONTAL SEPARATION wrn.—T TO BE axn
FROM EXISTING GAS MAINS MUST BE OBSERVED. m W TO Ka—no i moo':�o caws
w s•sn
N APPLICATION CITY OFLEPHYRIiILLS PERMIT PROJECT NAME:6I36 FORT KING RD COUNTY:PASCO
�� � � TO PLACE NEW CONDUIT CABLE CROSSING COUNTY RIGHTOF WAY DATE:S-I3-IS SECTION:3 TOWNSHIP:26 RANGE:21
W®E ENGINEER:HELEN FIFE DRAWN BY:K.L.
JOB DESCRIPTION: PRISM NUMBER:RI17Ra6 NTP N:207643 SCALE:NONE
Iv 9 CATV UNDERGROUND CONSTRUCTION TYPEOFPERMIT:C1TY TRACKING H: DRAWING SHEET:3 OF
ROAD
WORK
END AHEAD
ROAD WURK
A
■ c to '
B -1 Taper Length m V,,L Work Area
See Table!I END
Table I/
ROAD ROAD woRK Taper Length - Shoulder
WORK Device Spacing-Taper Device Spacing-Tangent 500
See Table I See Table I Speed YL(ft)
AHEAD SPEEDING FINES DO BLED (mph) 8' 10, 12, Notes
WHEN WORKERS Shldr. Shldr. Shldr.
PRESENT
25 28 35 42
Table I 30 40 50 60 L=WS'
Device Spacing 35 55 68 82 60
Max.Distance Between Devices(ft.) 40 72 90 107
_ Speed Cones or Type I or Type 1f 45 720 I50 180
(mphl Tubular Markers Barricades or Vertical - 50 133 167 200
DISTANCE BETWEEN SIGNS Panels or Drums
Spacing(!t.)
Taper Tangent Taper Tangent 55 147 1B3 220
Speed A B 25 25 50 2550 60 160 200 240 L=WS
40 mph or less 200 200 30 to 45 25 1 50 30 50 65 173 217 260
45 mph 350 350 50[0 70 25 50 50 100 70 187 233 280
50 mph or greater 500 500
'Midway between signs. 8 minimum shoulder width
YL= Length of shoulder taper in feet
SYMBOLS GENERAL NOTES DURATION NOTES W- Width of total shoulder in feet
(combined paved and unpaved width)
® Work Area 1.When four or more work vehicles enter the through traffic lanes In a one hour 1.Signs and channellzing devices may be omitted If all of the
period or.fess(excluding establishing and terminating the work area),the advanced following conditions are met: 5- Posted speed limit(mph) -
■ Channelizing Device(See Index 102-600) FLAGGER sign shall be substituted for the WORKERS sign.For location of flaggers a.Work operations are 60 minutes or less.
and FLAGGER signs,see Index 102-603. b.Vehicles in the work area have high-Intensity,rotating,
flashing,oscillating,or strobe lights operating.
[]I Work Zone Sign 2.SHOULDER WORK sign may be used as an alternate to the WORKER symbol sign only
on the side where the shoulder work is being performed.
b Lane Identification+Direction of Traffic
3.When a side road Intersects the highway within the TTC zone,additional TTC
devices shall be placed In accordance with other applicable TCZ Indexes.
CONDITIONS
4.For general TCZ requirements and additional information,refer to Index 102-600. WHERE ANY VEHICLE,EQUIPMENT,
WORKERS OR THEIR ACTIVITIES
c ENCROACH THE AREA CLOSER
THAN 15'BUT NOT CLOSER THAN
' 2'TO THE EDGE OF TRAVEL WAY.
R
LAST o DESCRIPTION:
REVISION 2 FY 2018-19 INDEX SHEET
FDOT TWO-LANE, TWO-WAY, WORK ON SHOULDER
11101117 s— STANDARD PLANS
102-602 1 of 1