Loading...
HomeMy WebLinkAbout19-21020 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 21020 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:21020 Issued: 3/27/2019 Address: 6679 WAGON TRAIL ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 17,732.00 Total Fees: 195.00 Subdivision: SILVERADO Amount Paid: 195.00 Date Paid: 3/27/2019 Parcel Number: 05-26-21-0080-00600-0400 CONTRACTOR INFORMATION OWNER INFORMATION Name: VIVINT INC Name: MARTINEZ, JASMINA& RAIVEN Addr: 4931 N 300 W Address: 6679 WAGON TRAIL ST PROVO, UT. 84604 ZEPHYRHILLS, FL 33541-2559 Phone: (877)479-1670 Lic: Phone: 813-480-9596 Work Desc: ROOF MOUNT PHOTOVOLTAIC SYSTEM APPLICATION FEES ELECTRICAL FEE 195.00 INSPECTIONS UIR D ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL i REINSPECTION FEES:(c)With respect to Rennspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City) Codes and Ordinances. (ILA F) C CAR PER OFFI PERMIT XPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER i CITY OF / / BUILDING ZEPHYRHILLSNOTI-CE . DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT# THIS JOB HAS NOT BEEN COMPLETED. he following additions or corrections shall be made before the job will be accepted. v eo It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Pertnittin 13 B \Q 0�.j I- Owner s Name rA ry E NH A 2r=N Owner Phone Number (0 13/ Ll b 0 Owner's Address Q NA t L S 1. Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address �- JOB ADDRESS U (p-i W A Cc tr�O fV rt P,r L S r. LOT# SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAMEQ STEEL Q t� tt� e 0 o f DESCRIPTION OF WORK 114 � d F' A ROOF "H O� I-Ob P�0 `-V VO LIRE L BUILDING SIZE I = SO FOOTAGE= HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA I TIN Address (( License# ELECTRICIAN �r Jam` COMPANY V v T N T S 6 L A P— D E,v E O ►Z SIGNATUR REGISTERED N FEE CURREN I Y/N Address 51 On W. HRNWA Q e•TAMP License# E G 13�10 / PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA Y/N Address I License# I OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA Y/N Address License# 1111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions8arge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and.contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not property licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEIgENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR U�. Subscribed and sworn to(or affirmed)before me this Subscribed and swor p jgr of i d)J�efr pi t is (`�^'1 by by /A ,� d(�v Who islare personally known to me or haslhave produced W 's/ar e,onall w me or haslhave produce as identification. as identification. Notary Public Notary Public Commission No. Comm on No. Name of Notary typed,printed or stamped Nam �prin a r,gt�lpt yi�� INSTR#2019044739 OR BK 9874 PG 1895 Page 1 of 1 03/18/2019 01:46 PM Rcpt:2037471 Rec:10.00 IDS:0.00 IT:0.00 PauCa S. O'Neil P6LD., Pasco county orerk&comptroller Permit No. Parcel IDNe _ —d 1—boat) — ooj g IlJ—U4vv NOTICE OF COMMENCEMENT state of Florida County of' Pasco THE UNDERSIGNED hereby gives notice that improvmrnent will be made to certain real property,and hi accordance with Chapter 713,Florida Statutes, the fc9aring Information is provided in the Notice of Cortunemxment 1. Deso"m of Property:Parrot Identification Nm ShastAddtes � 2. General DescdpW cf Improvement Installation Of a roof-mounted solar photo"Ditaid system & OwnerrIIrriamatlon or Laeaes information If the Lessee contracted forthe Improvement P.i�I�� WQ-rr.a.t �P0.rl .S�' lVt.lj1 FL— Address City stare Intmest in Property. Name of Fee Simple Titleholder (If different horn Owner listed above) 4. Adc dress or Wnt Solar Developer,LLC city State Name 5100•W Harms Ave Tampa FL--2N,14 Address City state Contractor's Tdapherre No_ (a13)359-122B 5. Surety: Nerne Address MY Slide ' Amount of Bond:$ Telephone No.: 8. LaMar Name Address City State. Landers Telephone No: 7. Pasam.within the State of Florida designated try the owner upon whom natices or other documerrb may be served as provided by Sedum 713.13(1xa)(7),Florida Stetutas Name Address• city state Telephone Nornber el Designated Person 8 In addition to hYimelf,the owner designates of to receive a copy of the UeroYs Notice as provided In Section 713.13(1)(b),Florida Stehdes Telophom Nranber of Person or Entity Daetgrrated by Owner: 9 Er#ratlar date of Notice of carmmeccement(the expiration date may not be before the completion of cam on and rml erd to the canbactor,but will be acre yearftan the data of recording urdess a di ferent date is spedtledr. WARNING TO OWNER ANY.PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THEN CEO COMMENCEMENT ARE CONSIDERED'IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1. SECTION 71&1& FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENOM OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under lar�ted� beHlI declare Bert I have read the foregoing of commen emend and diet the farts stated therein ate tam to Me best afnvy STATE OF FLORIDA Y COUNTY OF PASCO ' . ar Owners or Lessee's Authorized � irectlorm offica Silinatory Titiar The foregoing frmtnanent vise acknowledged babe me rids'Iday of A s 20 V� as (hype of suit",e.g.,officer.trusme.attorney In fact)for (name of pony on fished whom ins ell was esaarted). Personally Known❑ Produced Identificafbn%_ Notary Sl jnabae^ Type of Identification Produced—`12o�$C Name Wrin t) Notary Public State of 03,ride ; a4 Timothy A times y•_ My Commission GG 14798E +�jona► Expires 09=Q021 ant_pcD53048 \. } �XC���D u.TATEE�OF F',ORIDA, CoUav i Y OF F'a�S(;o THIS IS TO CERTIFY THAT THE FOREGOING IS A •� TRUE AND CORREC T-Copy OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE 4 WIT F I SEAL T�I I S MY HAND �� $,� � •• OF PA O' E ERK MPTROLLER �' o DEPUTY CLERK i i Vivint s,�� � r 1800 W Ashton Blvd. -J Lehi, UT 84043 Structural Group J.Matthew Walsh,SE, PE Samuel Brown, PE Senior Structural Engineering Manager Structural Engineer james.walshL7a vivintsolar.com sam.Brownt?a vivintsolar.com March 12, 2019 Re: Structural Engineering Services Martinez Residence 6679 Wagon Trail St,Zephyrhills, FL S-6068950; FL-01 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and. exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information,we have evaluated the structural.capacity of the existing roof system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Southern Pine#2 or better with standard construction components and consists of the following: • Roof Sections: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access to verify the framing size and spacing. B. Loading Criteria 8.02 PSF= Dead Load (roofing/framing) 2.59 PSF= Dead Load (solar panels/mounting hardware) 10.61 PSF=Total Dead Load 20 PSF= Roof Live Load (based on local requirements) Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) C. Required Structural Repairs The analysis performed has indicated that the existing roof will require the following repairs prior to installation of the photovoltaic array: I Hip Framing -The mounting hardware is not designed to support the array with the roof framing running horizontally (cross-slope). At locations where mounting hardware will be installed, install 2x4 blocks between existing framing members. Each end of the blocks must be secured to the existing framing members with a Simpson Joist Hanger, Simpson A34 Clip Angle on each side (2 total), or with (2) 16d sinker nails into the end-grain of the block. Page 1 of 2 v'v'nt. „j J I e i ;� i Page 2 of 2 D.Solar Panel Anchorage 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website (www.ecofastensolar.com). 2. The solar panels are 11/2'thick and mounted 41/2" off the roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above the existing plane of the roof. 3. The following mounting types shall be used. Please refer to the mounting details for the associated required penetration depth. Based on our evaluation, the pullout demand is less than the maximum allowable per connection and therefore is adequate. • EcoFasten Solar: (1) 5/16" lag screw. Pullout capacity based on National Design Specifications (NDS) of timber construction specifications for Southern Pine is 235 Ibs/inch penetration. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above, using the wind load uplift procedures of ASCE 7-10 and is specified below. These spacing requirements apply to all mount types indicated above. The following values have been verified by in-house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections should be staggered,where possible,to distribute load to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ede Corner Interior Ede Corner Max Vertical Spacing in 40 40 40 66 66 66 Max Horizontal Spacing in 48 48 48 48 48 48 Max Uplift Load Ibs 369 294 271 623 495 457 E.Summary Based on the above evaluation,with the structural repairs completed as prescribed and appropriate panel anchors being utilized,the roof system designed on will adequately support the additional loading imposed by the solar panels, if installed correctly.This evaluation has been performed for the structural elements only and verifies that they are in conformance with the 2017 Florida Building Code- Residential 6th Edition, current industry standards and practice, and the information supplied to us at the time of this report. If there are any questions regarding the above, or if more information is required, please contact me. HE IM Regards, J. Matthew Walsh, PE :* N 84 FL License No. 84923 STATE OF ; 0 , /SS,ONAL 1/l 11 111 03/12/2019 v'v'nt® ,S sl1 ,Y� i vivint s' cr 1800 W Ashton Blvd. • s"` i '! 'a Lehi, UT 84043 Structural Croup J.Mafthew Walsh,PE Samuel Brown,PE Senior Structural Engineering Manager Structural Engineer 7ameavmish(a),vivinmolarcom sam brown(Mvivinmolar com Structural Analysis Report Project Address Date: March 12,2019 Martinez Residence 6679 Wagon Trail St Zephyrhills,FL 5-6068950 Residence Roof Area 2423 sf Upper Floor Area . 1817 sf Number of Stories 2 Type of Construction Wood-Framed with Rated shear panels Mean Roof height 25 ft Upper Floor height loft Location Parameters Latitude 33.841 Longitude -117.85 Site Class D Risk Category II Seismic Parameters SS= 1.50 g 0.2 sec Spectral Response Acceleration SI = 0.55 g 1.0 sec Spectral Response Acceleration Fa= 1.0 Site Coefficient from ASCE 7-10,Table 11.4-1 FV= 1.5 Site Coefficient from ASCE 7-10,Table 11.4-2 SDS = 1.00 g Short Period Design Spectral Acceleration SDI = 0.55 g I Second Period Design Spectral Acceleration Wind Parameters Wind Speed 145 mph Exposure Category D Roof Angle, 0 22.4 deg , Product Information No.of Panels 26 Weight 2.59 psf including mounting system �%c E N s�.;9� tS� Installed Area 457.2 ft2 �' S No.of Connectors 34 * i`1c�84 3 Summary C,� STATE OF ;� = Mexistin = 2876.671b-ft �� �'�� g �j COR1O,. Mnew= 1089.171b-ft ss NA I �1\?\\\3\12/2019 Total Stress Due to New Gravity Loads is less than Existing Loads.OK Page 1 of 3 viv1 ns ' . L L Existing Structural Elements Carrying Gravity Load 2015 International Existing Building Code Section 807.4 2015 International Residential Code Section AJ501.4 2017 Florida Building Code-Residential 6th Edition,Section AJ104.1 Existing Roof Dead Load Roof Live Load Floor Dead Load 4 psf Composite Shingle 20 psf 7.50 psf Floor Finishes 2 psf 3/4" Plywood Sheathing 3.30 psf 1 1/8" Subfloor Sheathing 1 psf Roof Framing @ 24 in.o.c. Ground Snow Load 3.40 psf Joists @ 16'o.c. 0 psf Ceiling,Mechanical,Electrical 0 psf 15 psf Partitions 1 psf Miscellaneous 3.60 psf Ceiling,Mechanical,Electrical 8 psf TOTAL 1.25 psf Miscellaneous 34 psf TOTAL Wall Dead Load 8 ft Wall Height Floor Live Load 300 ft Wall Length 40 psf 12 psf Wall Weight Additional Roof Dead Load Roof Live Load with Solar Panels 2.59 psf Solar Panel Weight 0 psf Total per Rafter Total Existing Roof Load=DLRooF+(LLRooF or Snow)x Spacing 56.04 plf Total New Roof Load=DLRooF+DLADD+(LLRooF or Snow)x Spacing 21.22 plf Change in Demand=(Total New Load-Existing Load)/Existing Load -62.14% Total New Gravity Loads are less than Existing Loads.OK 2015 IEBC Section 807.4 states: "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting such reroofing or equipment shall comply with the gravity load requirements of the International Building Code requirements.EXCEPTION 1.Structural elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." i 2015 IRC Section AJ501.4 states: "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous condition is not created.Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code." 2017 Florida Building Code-Residential 6th Edition,Section AJ104.1 states: "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive reconstruction shall not be required to be evaluated." Page 2 of 3 v'v' r • <_ i Wind Uplift Simplified Procedure for Components and Cladding ASCE 7-10,Section 30.5 V= 145 mph Basic Wind Speed Exposure D ASCE 7-10,Section 26.7 = 1.61 Adjustment Factor for building height,ASCE 7-10,Figure 30.5-1 Kn= 1 Topographic Factor,ASCE 7-10,Section 26.8.2 Roof 0= 22.4 deg sanehor= 48 in Horizontal spacing of roof anchors At b= 12.80 sf Panel Area tributary to each roof anchor Pnet30 Net Wind Design Pressure,ASCE 7-10,Figure 30.5-1 Roof Zone Zone 1 Zone 2 Zone 3 As shown in ASCE 7-10,Figure 30.5-1 31.5 psf 49.1 psf 89.3 psf Pnet= \KztPn.t30= Design Wind Uplift Pressure,ASCE 7-10,Equation 30.5-1 Zone 1 Zone 2 Zone 3 51 psf 79 psf 144 psf Pnet= 16 psf Minimum Design Wind Pressure,ASCE 7-10,Section 30.2.2 Use 51 psf Use 79 psf Use 144 psf Connection to Existing Roof Framing F.S.= 1 Additional Factor of Safety applied to withdrawal force,if desired Atrib= 12.80 ft` DLpanel= 2.59 psf Zone 1 Zone 2 Zone 3 Wnpha= 51 psf 79 psf 144 psf Pia,=F.S.x Atrib x(0.61)-0.6W) Withdrawal force for each roof anchor Zone 1 Zone 2 Zone 3 -369.0lbs -293.6lbs -270.91bs Connection Capacity db= 5/16 in Lag Screw diameter Dpen= 2.50 in Lag Screw penetration into existing framing member Southern Pine Species of wood framing CD= 1.6 Load Duration Factor for Wind Loading,NDS Table 2.3.2 Ct= 0.7 Temperature Factor,NDS Table 10.3.4 W= 235 lb/in Withdrawal Capacity NDS Equation 12.2-1 W'=CD x Ct x W= 263 lb/in Adjusted withdrawal value Panow=Dpen x W'= 657 lbs Based on penetration depth Zone 1 Zone 2 Zone 3 DEMAND= 3691bs 294 lbs 271 lbs Max Load=0.561 OK CAPACITY= 657 lbs 657 lbs 657 lbs Page 3 of 3 v, ' I i s www.jinkosolar.com � K0 Eagle 60 ® ® / Witt MONO MODULE positive power toleranceo 0 - - -- - -- - KEY FEATURES II�III Innovative Solar Cells Five busbar monocrystalline PERC cell technology improves module efficiency High Efficiency S+* Higher module conversion efficiency(up to 18.94%)due to Passivated Emntiter Rear Contact(PERC)technology I.. PID Free em-raEr World's 1"PID-Free module Low-Light Performance wwucNr Advanced glass technology improves light absorption and retention Strength and Durability oP°,' Certified for high snow(54001'a)and wind(24OOPa)loads Weather Resistance El Certified for salt mist and ammonia resistance LINEAR PERFORMANCE WARRANTY ISO9001:2008 Quality Standards 10 Year Product Warranty • 25 Year Linear Power Warranty • •ISO14001:2004 Environmental Standards •OHSAS18001 Occupational Health&Safety Standards Nomenclature: ®taowarrantyLinear performance warranty JKM31 OM- 606 U97% ggartf Standard performance warranty null 8 White e1 95% �n8�VarVe from Jrpko e slack a aosc Sear,"near Y o wa7ant v ^ d C UL US L 802% ro ma , LISTED co years 1 5 12 25 Engineering Prawings, a ■- s-•. •. 992±2mm(39.06') 40mm(t.5T) 942±2mm(37.09.) Current-Voltage&Power-Voltage Temperature Dependence _ A� _ Curves(310M of Isc,Voc,Pmax IIIII I' !I!11I'll II --- tm li IIIII soo ,ao ,o IIIII I! I!'I;!I'llL'll'. i 3 _2W d s Isc a as g >too ° - F max ao IIIIIII �I III,' I: i•,• I' lil o IIIII I' Il:i !il;'i LI'i o 0 5 io +s 2a 2s -VJ , FFI I I I w NJ -50 -25 . 25 SO 75 tW Voltage(V) Crll Tempemture('q Mechanical Characteristics, Cell Type Monocrystalline PERC 156x156mm'(6 inch) No.of Cells - - - -- - -60(6x10) - - -----' Dimensions 165Ox992x4Omm(64.97x39.06x 1.57 inch) a -------L' - Weight 18.5 kg(40.8 lbs.) A� Front Glass - - - 3:2mm,Anti:reflection Coating, High Transmission,Low Iron,Tempered Glass Packaging Configurations - w Frame Anodized Aluminium Alloy(Black) (Two boxes=One Pallet) w Junction Box, -nr IP67 Rated 26 pcs/box,52 pcs/pallet,728 pcs/40'HQ Container Output Cables 12 AWG,Length:900mm(35.43 inch) Fire Type- -- - T — - Type_1 Module Type JKM29OM-60 JKM295M-60 JKM30OM-60 JKM305M-60 JKM31OM-60 SIC .NOCT STC NOCT STC NOCT STC NOCT STC NOCT { Maximum Power(Pmax) 290Wp 216Wp 295Wp 220Wp 30OWp 224Wp 305Wp 227Wp 310Wp 231 Wp Maximum PowerVoltage'(Vmp)- — 32.2V •3O.2V 32AV 30AV 32.6V 30.6V 32.8V 30.8V 33.OV '31.OV, Maximum Power Current(Imp) 9.02A 7.15A 9.10A 7.24A 9.21A 7.32A 9.30A 7.40A 9.40A 7.49A Open-circuit Voltage(Voc)_ - -4 39.5V _36:6V 39.7V 36:8V -�40_1V 37.OV-- 40.3V-37,2V 40^5V 37AV Short-circuit Current(Isc) 9.55A 7.81A 9.61A 7.89A 9.72A 8.01A 9.83A 8.12A 9.92A 8.20A Module Efficiency STC(%) 17.72% 18.02% 18.33% 18.63% 18.94% Operating Temperature(°C) -40°C-+85°C Maximum System Voltage 1000VDC(UL and IEC) Maximum Series Fuse Rating 20A Power Tolerance 0-+3% ! Temperature Coefficients of Pmax -0.39%/°C Temperature Coefficients of Voc -0.29%/°C Temperature Coefficients of Isc 0.048%PC Nominal Operating Cell Temperature.(NOCT) 45±2°C *STC: IN.Irradiance 1000W/m2 19i Cell Temperature 25°C ' J) AM=1.5 NOCT: i4c1rradiance 80OW/m= 1I Ambient Temperature 20°C AM=1.5 ) Wind Speed 1m/s " Power measurement tolerance:±31 CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. L Jinko Solar Co., Ltd.All rights reserved. Specifications included in this datasheet are subject to change without notice. US-MKT-310M-60 1.0 rev2017 S0 Ice)r _ . ® �, So/arEd for �'e 'ogle Phas e Se /nvor�.or r� SE3066 _ SE76 p pN US 1 SE380OH_US 1 SE 5pp pH'US/SE600QH-US solar [j Y. b :Waeeaanty s y r A.may *9 9 Or yt a ` Tw- ..� optimized instatiatio Specificapy desi n Witi� Recor . gned to eHj)Wave t d breaking effic.0 York with pow ptimi echnoiog, • Fixed voltage Irate d f fa erter for longer strings grate " UL uIt Protection gs ' dw Extreme/ SA certified, for and rapid shutdown ExtremelY small CPUC Rule for NEC 21 grid EC 2014 and 2017 High reliabilit and easy to in compliance per ar• f Built-- Y with outdoors or indoors -article 690.11 I module- any electrolytic c ors and 690.12 1 .. Optional:Reve level monitoring apacitors USA- nue grade data,ANSI C12.20 Class 0.5 Jr(0, accuracy) "4_11 SOUTH AFR1CA-P UK H RF_THE NETH 1 D(AND-CZECH REP ERCANUS-JppAN- d A�� Y PUBLIC CHINA-AUSTRALI4-I r�/ e. SRAEL-FRANCE-BE(Gf UM-TURKEY-iNDIA-BU(GARfA-ROMANIA-HUN GARY-S WE,6V- - wWw.solaredge,us solar=se Single Phase Inverters for North America SE3000H-US/SE380OH-US/SE5000H-US/SE6000H-US/SE7600H-US SE3000H-US SE380OH-US SE5000H-US I SE6000H-US I SE760OH-US OUTPUT Rated AC Power Output 3000 3800 5000 l 6000 7600 VA .......P........g...................(......... ... ). ................... ....... Max.AC Power Output 3000 3800 5000 I 6000 7600 VA ........... ......................................... ........ . ........ ......... ......... ................... AC Output Voltage Min:Nom:Max. 183-208-229 - ✓ Vac ............................................. .................. ................... ........................ ..... AC Output Voltage Min.-Nom: .........Max.(211-240:264) ✓ ✓ ✓ ✓ ✓ Vac :............................ ........I...................,................... ........... AC Frequency(Nominal) I 59.3-60..-60.51 I Hz . ................ Maximum Continuous Output Current 208V 24 A ................................................... ................... ................... ...... ... ............ Maximum Continuous Output Current 240V 12:5 16 21 2S I 32 A ........ . GFDI Threshold 1 A ......................................................... ................................................Yes....... ............... Utility Monitoring,Islanding Protection, Country Configurable Thresholds INPUT Maximum DC Power 4650 5900 7750 9300 11800 W Transformer-less,Ungrounded Yes ......................................................... ....... ............................. ....... ......... .. .... Maximum Input Voltage............................... .......................... ....................480.................I...... Vdc ....................... Nominal DC Input Voltage 380 400 Vdc ............ .... ....................................... ...................�..... .... Maximum Input Current 208V"i 13.5 Adc . ......... .... ............... Maximum Input Current 240V Ili 8.5 10.5 135 16;5 20 Adc ....... Max.Input Short Circuit Current 45 Adc ......................................................... ................................................................................................... ............ Reverse-Polarity Protection Yes ......................................................... .................. .................................................. ........... Ground-Fault Isolation Detection 6001cst Sensitivity ......................................................... ................... ................................................. ,............ Maximum Inverter Efficiency ........99........I................................I....99...........I..................I........ ..... .. CEC Weighted Efficiency 99 Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) ......................................................... ...................................................... ............ Revenue Grade Data,ANSI C12.20 Optional131.I............ ............................. Rapid Shutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFCI according to T.I.L.M-07 ....................................................... ..............................................................(..i................................. ............ Grid Connection Standards IEEE1547,Rule 21,Rule 14 HI Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 0.75-1" Conduit/14-6 AWG ................ .......................................................... ............ DC Input Conduit Size/#of Strings/AWG Range 0.75.1" Conduit/1-2 strings/14-6 AWG ...... ...... ........... ................... .... Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm I.. ....... ..... .......... ...... ....................... ............... Weight with Safety Switch... .... ...... ............. ...................22/?�.... ......... I... .... ..1...... (..............26.2/11:9..... .... ... .."lb/...... Noise <25 <50 dBA ......................................................... . Natural convection and Cooling Natural Convection internal fan (user replaceable),,. Operating Temperature Range -13 to+140/-25 to+60("(-40'F/:40•C option)ts) •F/'C .......... . . .... .. Protection Rating I NE MA 3R(Inverter with Safety Switch) ........... .......... ...... ......... ......... .... ........... ul For other regional settings please contact SolarEdge support A higher current source may be used;the inverter will limit its input current to the values stated ul Revenue grade inverter P/N:SExxxxH-USOOONNC2 Power de-r ating From 50'C �sl-40 version P/N:SExxxxH-USOOONNU4 0 SolarEdge Technologies,Inc.All lights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BY SOLAREDG E are trade=rks or registered trademarks. .. - Date: e: a ��- 1800 W Ashton Blvd TM Lehi, UT 84043 vivint-Solarelectricianlicensing@vivintsolar.com I www.vivintsolar.com Phone:801-845-0286 1 Fax: 801.765.5748 January 25, 2019 To Whom It May Concern: I,the undersigned licensed contractor, authorize my employees, named below, to act on my behalf on the performance of the actions listed below: Catherine Russo Ashleigh Janssen James Quillen Adam Mcauley David Hamel Approved Actions: Act on my behalf on any and all matters and dealings including signing plans, paying for/picking up plans/permits, obtaining business licenses, etc. within the City of Zephyrhills. For questions concerning this authorization, please contact me directly by email at electricianlicensing@vivintsolar.com or by phone at 801-845-0286. Best regards, State of: Utah County of: Subscribed and sworn to before me this 0::5 day of m the year 201 Cody Cram State Contractor License#EC13006740 Janee Lyne adfield, otary Public Exp: 08/31/2020 My Commission Expires Oct.28,2020 i C: 801-369-4950 0: 801-845-0286 i JANEE LYNETTE HADFIELD x�f � Notary Public State Of Utah My Commission Expires October 28,2020 ° COM',il'SSION 9691767 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: V 1 Ve /0 � Date Received: Site: l� / Permit Type: ,{-h54-A j1r4,0A O� Y'0 0� pot,'-'1il ys�e nl) Approved w/no comments: ' Approved w/the below comments: ❑ Denied w/the below comments: El I i i This comment sheet s 1-1-be kept with the permit and/or plans. MAR, 2 4 2019 Kalvin itzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present)