Loading...
HomeMy WebLinkAbout19-21137 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020.,. 21137 BUILDING PERMIT PERMIT-INFORMATION LOCATION INFORMATION Permit Number: 21137 Address: 39978 6TH AVE Permit Type: COMMERCIAL ZEPHYRHILLS, FL. Class of Work: NEW CONST/COMM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 07-26-22-0000-00300-0010 Improv. Cost: 628,000.00 OWNER INFORMATION Date Issued: 4/30/2019 Name: US GOVERNMENT Total Fees: 4,830.00 Address: GENERAL SERVICES ADM Amount Paid: 4,830.00 WASHINGTON DC 20405 Date Paid: 4/30/2019 Phone: Work Desc: INSTALLATION NEW LIFT STATION W/ELECTRIC BY AIRPORT CONTRACTORS APPLICATION FEES POSPIECH CONTRACTING BUILDING FEE 4,410.00 CHUCK'S STOKES ELECTRICAL OF CE ELECTRICAL FEE 420.00 C, �2 ns ections Re uired FOOTER 2 N D R OTJ H P UMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME. MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. . NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received C phone Contact for Permitting ' 3 3 S — �V 5 Owner's Name W S G d V Q sM v-- Owner Phone Number Owner's Address I Ca Lw GN v ce-3 Owner Phone Number Fee Simple Titleholder der Na Nam ! ` �d��� Owner Phone Number Fee Simple Titleholder Address // JOB ADDRESS 1 bNJ LOT# SUBDIVISION PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW COLSTR B ADDI REPAALT IR SIGN = = DEMOLISH PROPOSED USE = SFR COMM = OTHER TYPE OF CONSTRUCTION '= BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK �♦ , S — G.S �'S \�►�^� BUILDING SIZE SO FOOTAGE HEIGHT EVALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ Q OCR ©CAMP SERVICE Q PROGRESS ENERGY W.R.E.C. =PLUMBING $ j� P o =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION Z � =GAS = ROOFING 0 SPECIALTY = OTHER � C� FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA Y/N —_ �\ 1_—Addressl __3_ ---License`#- ELECTRICIAN COMPANY �— �S STVF��� T`� `� SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address F\1 qA License# C.puG�CJZ.. PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN LILN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# IIIIIIIIIIIII111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormmwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)Complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions. Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 89» cRy Of zaphyrhWs Pflfl}t Appj{Cll{)on 1 87 9 Sutldtrg DepobnWd ftmftNam. Gov s����•+�•"� o�n..R,onoNrmriree OWmftAd*d 4t. %r.Z E• AWO' OveseaPboMNumbar 71 %f?ee lYt�le� �� — ���`► 9weerPtraes llaraier Rae 8lntpk At4dreee JONA®BRM LOT# lUliBf�ICN PAR#'. IL 00 (�i►9®t+9gM e1gP�ir t]18 aai1BO WOMPROPOW NZWCMM[3 ADDIALT ® SIGN ® ® OEMOUBH INSTALL REPAIR 1818 �] BFIz ® COMM ® OTHER TYM OF WkwMXM ® BLOM ® FRAME ® STEEL bmil1tfm0N O!SIwom IISACO6tfi M lO PQIZTA6f1 1fePGilY Mamma i�' VALUATION OF TOTALCONETRLICT(ON ® AMPS ® PROORm ENERGY WJLLC. ®PLUMswe Enum irAL VALUATION OF MECHANICAL INSTALLATION ®pAf ROOFINCI ® spacmirY® CTm RR FINISHED FLOW ELEVATIONS FLOOD ZONE ARPA ®YES NO BUILDER foe P��pirj �, GDnt 'tA Ar%q ax"TURE I sT®teD FEE a)RM Y f M Addle" 1 low 4 ` B r.91IPAW b 4%%roNw. ' •� /fO11AT11 REGISTERED rae com Address Lto�ane®N PLUM SB COMPAW l 81011ATM REMITZrea I YIN pEacumm I YIN Lb.rre 1 Y>ceRANleu cow my fllf4iN1AT1J r'gatsrmrEnL11 N J rs[eteu m Ads ucertee a OTH1911 COMPANY 11011AT PE(9wrff D I YIN FS6mMm / A4�eis Lleenw i PAMDZKnAL IIIB111111111111111111111111111111111111111111111111111111111111111 A2ec4r ®a'%of Building Plins;(1)eat d Energy Fermi;R-0-W Penrtit fa rAm omsuwftn, 6Rnlnxanr ton He! n2 op oiltar sufxr tUl data.Ragtdted amb,C.crehcLloa Platte,fttm War Pins Wall Few hoWled, berJhq Fadgm&t dwnpeter;Olte Wark Permit for aa&dlvlebn tw projeete COMMEMMAL Ahab R)awro is sate of BuUM Platte plye a Lfh f9tfety Papa;(1)a d d Energy Forme.R."Psm*for now cm"wdsn. hftl rarr tart(10)trR Mng drys KW eubmlgel date. Rsgrdted anal I Construalan Plea,BtcrmwWr Plena rd Blt Feriae Irmi&ed, swft+Fadmae 61 dimpstsr.Lilts work Permit for ap now projects.All commeairl Mgwwnm must moot eomplluw /11N1 P91WIT Aftah M eats of EttgintKW Pyre, "°"PROPERLY SURVEY requimml laral NEVf eonaimalcrt. . . . . .. . . .. . . . . . . . . . . . . . . . . . . . . . . . FE out tpploetbn aornpta". Oww A CaffiweW Op be&of spplosam%natteied %Dear�6,■Notl�of Catrvnenoereent M requtnd (Fife upffmdee amr$7M Apt(laelFsae )arPmkeralAtiorrwfoftiXYhaowner)waufdbaeomennarAthtator�dtsl�rhomtrxneret+bwt�rfpsame craR THE coumm (espy of o ragtdded) Rsradfe 9 shh*11 11119100m; SstYlce Upgtedee A/C Fences( yWoote a) awv OmmA rr tf an publa rae top s RCW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations._The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed:and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner',I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTI MMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this S bscr bed and sworn to(or affirmed)before me this by by C�..—%=d - S b,.\'da.1 Z C, Who is/are personally known to me or has/have produced Who is are personally know_n to me or has/have produced as identification. as identification. Notary Public C p c� Notary Public o�[Commission No. fission N ' \�, LA\ Name of Notary typed,printed or stamped Name o177= 71 Y NEAL CECIL ion �FF 997841 mission Expires 01. 2020 CHUCK'S STOKES ELECTRIC OF CENTRAL FLA INC. P O Box 930 OCALA, FL. 34478 352-351-4605 OFFICE 352-351-4436 FAx ff: u . City of Zephyrhills Building Dept 4/2/2019 I, Charles B Stokes Jr,from Chuck's Stokes Electric of Central Florida, Inc, authorize Zachary Cecil to sign on behalf of Chuck's Stokes Electric for any permits. SINCERELY, Charles B Stokes,Jr. President Chuck's Stokes Electric of Central Florida, Inc , 'Y"" SHARI PRIVALLE z: ± :Commission#GG 072M Ex�resApril9,2021 80p38y7pt9 "!•:•<. +ThruirayFVnsurenoe „ v•., fiord , k City of Zephyrhills BUILDING PLAN REVIEW COMMENT`S/ Contractor/Homeowner: YTO R I Date Received: "/ Site: 3 9 � 1 7 9 Permit Type: ./,4, Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment she t shall be kept with the permit and/or plans. Kalvin wi er—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) .wTv-mIs--d T--xio pie 3aHaRplm aS[a[mawj dm3o inq v*m onn me 31 n!PMB!Pg atg #aRE P�3alo8ataq a*Pans aesq,M wgaap 1'AmWd3o saplsaad mPDII' alS vpjmja'SLS'Z6 aol-S of W--d aoR-m-A paonpwjaolmgwapI3oadSL v�Us�I34ialoN _ao[pTo9RqPIPaaaPDldiI0 uaaotTXA[PTwand ` •{polnoaxo seas iaanmr;sal.aTogm o31Sgaq ao dzss o sa3(�Tn danm>;s ha>iazF' o`d a'krtogiaa3o edlCj 6q BUT/�OZ P X3P sPN am P°I�omPs sem vmmnlinq 3 nLL rtrNa UZv fdowN leuelles 48nom Papao9 f-sZidi`£I Inv satldx3•wwo�Rly ' tick raFa»� ema++Om�+Oaor�is 1iLfOL'M�Y uo1a] L� .�� oplia d 10 ms-311gnd LtelaN ti;r. o xa�uto� Nv1M IN I IYol ',!hr doarvls no,ma xamodd v DIv 2io usam'I-4aox L msxoa`Jmotjvma MRLSO O,L QNff LNI Ao]L tit '90=xasNl •L3211ai$SL as a m am aor am NO amoa QNw(mmoon 9ff,ie4aw,LNmffJN3moo flO ta0Id.0N v 'AmMOUA IMOQL 01 SLNZMAO7iJM MOd MMU 0MlVa IMOA NI JLT1 ?I NVJ aNv`s&LuvLS YQC>au '£I'£TL momm II.Luva'£ib UnavYiJtI ama SLN'aB xva Imos NII agaff(IISNOO Ray.LNS>+ aaxz ()D 40 ZOUON=L AO NO1LvtIIMM MU IIff,L!IV WHNMO MU 2M$QVW SLItI3MVa.AMV 'H&4M0 01 JMMWAA nogaI rIIo�IT;uId Ia3s> noT>r auo 6i/Oi/L I aq o;sops. 8I/£Z/L(d.LN)Ya;o id of aor (pa3F0 sj.wp l�[p a worm*gpmat�O alep ot1 -04 aao el qq W.421! aq;)3aaWaavmiwJ3o oagoXJo alsp�gSRdKT6 (,;do)-oK Yvg- 7 :'ox oaogdato y(R :51 r l is pav atuum(a -q-S m Papinold se aagaN S.Z=rI vtP3o Adoa■a400a,t o;«oerad ffIm0[I03 aql saW021saP Iottmo 7[MMnq CO aopiPpa tTR (';dO)'oklxwd OZ00-08L-6i8 :'oNaaagda[a3(q 'Z6SEE sPIIoI3`snyq T{ aZ`laa.4S q;3 SEES" '( aZ3o tD 13psog Tiro j :seatppv p� K(s sas-pae aq dsm s;aa=op taTpo.so saapoa taogm aoda.ammo ARP IMP aPlmld3o olal5 ag;alglla aosted3a kpmpi'L "UK oUogd :ssaipps Pas OWN(s =PWT9 (Ydo)'ON kVA tsN avngda[a.L(o pjq a,P Jo Tuavad aeu :Pwgjo=wmv(q 9ITZ{I'rllarsu •uotr 7aaq ti 6ued »uema nta :—tPPa Ptea aan)q(I gn�if oa S fnfAe SLi• �'J QI R wAu+q�'T apnatmo;al AIa�S'S {zdO)•o[y xag ors¢-9r�-ue :'orI SQogdalay(g ZSii£EPP%3 martianvT anaaey nldadv'S rim-jq strp muo:)giataod MwPP9 pm QMN(2 = a01;8aI7t13¢I IO;D871aD�'ir disadotd.a;7ewalal(o (Iaamo tisga 12*0 ji)sap[oga[Ig a[daga 2a33o NUM Pas SMIJ(q ZpS£E EP?Ioi3`sat L(, daZ'panS xD9 SEES'S[I!414lq aZ3o Allo :firlm ptm am m(it aopuut��riamO'£ Ju i M Mad aql UnPVA PaZ9ao7• M lm- lJ.L J T¢nvia Ai FAA aE�w uurtwuuw 1pm stair S UM vI loa P'PT°A=IU u Pu*e9=eaoPel AM, auo(T)p aop7=9UO3;elaam0A03 IMt30110pCbZMP PuaMUZ Zl?S£E -py2a` iT ,4 'animV t[39 - SL66C : >JMS(s C•'uolu4-W p&7)6uadoid3o mop l.wmQ•I .LbMMKgj oa aIo 3DUON W Ur MqAotd s<tmllmx3%Vo[ew[[o3 a*tmn 13%4mld a'930 EI'£IL MIMS tplm aaaePtoaos T$pw 14tadazd[Sat o;opem aq IL--m2wmidsq mp pql-4=mM eel AR=q aamismama ma OI00 OOEo0 0000 ZZ 9Z LO 'oN opwggwpIAuadosd L� 1� 2- •oN;Im�d IRMUNZWK00 No u u .ta[[oildwoo 8 MJ8[3 Alunoo oared 'Q'4d '[iaN,0 -S vinwd 00'0 :lI 0010 :SQ 00,01 / tla1SNI 0,0i :oas MOM :idoa 7d "Wit SOL �d s9t66 6�a 8 £ 6O6Z0Zt/81SNI Y CITY, OF / / / / BUILDING tEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT 21 1 -� THIS JOB HAS NOT BEEN COMPLETED, The following additions or corrections shall be made before the lob will be accepted. U'_�2 J e, It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0 0 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR !7 � r� CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS D TE PERMIT 70 (� �`U� 2lie THIS JOB HAS NOT BEEN COMPLETED, The following additions or correcti ns shall be made before the job will be accepted. �C_F_T F eb L4 N A N CoA­G�cT tNidELi her - L4 It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. fl OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR Vo , PLOTTED: 2/15/2018 12:02 PM JON ALLEN F POWER AND CONTROL WIRING SCHEDULE F WRE DATA CIRCUIT FROM TO HP VOLTS QARC GROUNDING(C) CONDUIT REMARKS NUMBER POWER OR CONTROL NEUTRAL N � ) P100 INCOMING SERVICE SERVICE DISC. 480 - - 3' BY POWER COMPANY P101 ENTRANCE BKR ATS 480 4-3/0 1-1 3" P102 GEN SET ATS 480 3-3/0 1-1 3' P103 ATS MCP #68 480 4-3/0 1-1 3' P104 MCP #68 JB 480 4-8(+) 1-10 2" P1 POWER (INCLUDE OTHER CONDUCTERS AS PER MOTOR MPR02) P105 MCP #68 JB 480 4-8(+) 1-10 2" P2 POWER (INCLUDE OTHER CONDUCTERS AS PER MOTOR MPR02) P106 MCP #68 PNL L1 240 3-8 1-10 1' E E P107 PNL LI GEN SET 240 2-10 1-12 1' GEN SET H7R P108 PNL L1 GEN SET 120 2-10 1-12 1" GEN SET POWER P109 JB WETWELL 480 CFWE P110 JB WETWELL 480 CFWE Pill SERVICE DISC. METER 480 3-3/0 1-1 3" P200 MOTOR SERVICE DISC. 480 4-3/0 1-1 3" P201 ENTRANCE BKR ATS 480 4-3/0 1-1 3' P202 GEN SET ATS 480 3-3/0 1-1 3' 8 P203 ATS MCP #69 480 4-3/0 1-1 3" P204 MCP #69 JB 480 4-6(+) 1-10 2" P1 POWER (INCLUDE OTHER CONDUCTERS AS PER MOTOR MPR02) P205 MCP #69 JB 480 4-6(+) 1-10 2" P2 POWER (INCLUDE OTHER CONDUCTERS AS PER MOTOR MPR02) w P206 MCP #69 PNL L1 240 3-8 1-10 1' I p P207 PNL L1 GEN SET 240 2-10 1-12 1" GEN SET POWER D P208 PNL L1 GEN SET 120 2-10 1-12 1" GEN SET POWER P209 JB WETWELL 480 CFWE P210 JB WETWELL 480 CFWE P211 INCOMING SERVICE METER 480 4-3/0 1-1 3• W U C100 MCP #68 JB 120 6-12 1-12 1 1/Y FLOAT C1o1 JB WETWELL - CFWE 1 1/2" FLOAT zC102 ATS RTU 120 6-12 1-12 3/4" ATS STATUS TO RTU o C103 ATS GRN SET 120 SEE REMARKS 3/4" AS READ BY MFR v~i C200 MCP #69 J8 120 6-12 1-12 1 1/2' FLOAT rz C201 JB WETWELL - CFWE 1 1/2" FLOAT ► C202 ATS RTU 120 6-12 1-12 3/4" ATS STATUS TO RTU o0 C203 ATS GRN SET 120 SEE REMARKS 3/4" AS READ BY MFR 0.C C o S100 MCP #68 JB 4/20 1 / TSP 1 1/2' ANALOG SIGNAL LEVEL S101 JB LT 1-10 4/20 CFWE 1 1/2' ANALOG FROM LT S102 MCP #68 ANTENNA - CFWE 3/4" AS REDD BY MFR o S103 GEN SET RTU - SEE REMARKS 3/4" AS READ BY MFR Ia a S104 PUMP RTU - SEE REMARKS - AS READ BY MFR j 5200 MCP #69 JB 4/20 1 / TSP 1 1/2" ANALOG SIGNAL LEVEL S201 JB LT 2-10 4/20 CFWE 1 1/Y ANALOG FROM LT S202 MCP #69 ANTENNA - CFWE 3/4" AS REDD BY MFR S203 GEN SET RTU - SEE REMARKS 3/4" AS REDO BY MFR S204 PUMP RTU - SEE REMARKS - AS REOD BY MFR LU Z o PL UB 8B O N 10 Y c Z itNj„1 N,ry'o •,• iiNo 48898 a DE51c1ED M CLARK 41!OMNES �' a r N0 oRh: a \` CITY OF ZEPHYRHILLS 3 F 10-o18-ot FEB 2018 oaNtN J ALLEN EDMUNDS AIRPORT LIFT STATION AND FORCE MAIN POWER CONTROL WIRING SCHEDULE `ND 0MG N0:II II; LtR 0RtE IiE�51oN5 �, OfO ED J OPPOLD 730 NE WALDO ROAD,CAINESVIILE,FLORIDA 32641/(352)377-5821 PASCO COUNTY,FLORIDA •• �••' E5 7 6 5 4 3 > +sso V• ,�� ''rrIrrrrruu111up lV%„``'` I 7I PLOTTED: 2/15/2018 12:00 PM JON ALLEN I ' • F RADAR LIQUID LEVEL DETECTOR AND TRANSMITTER - F MOUNTED IN TOP OF WET WELL(REFER TO PLAN) SS CABLE HANGER TRIPLE DOOR ACCESS HATCH r/LOCKSET AND RECESSED HANDLE(3E x84 CLEAR OPENING) (HALLIDNY PRODUCTS 5383684) ELECTRIC SERVICE METER CONBINA1TON AND CONTROL PANEL AIR ACUIMI VALVE T E E REFER TO ELECTRICAL EXPLOSION PROOF JUNCTION BOX. SEE DETAIL M3 COMBINATION REFER TO ELECTRICAL \/ EMERGENCY PUMP HOOKUP. AIR ACUUM VALVE 4 CAMLOCK W/DUST CAP. QUICK SEE DETAIL M3 TOP WET WELL FL(SEE TABLE) 6. FDA DISCONNECT W/FEMALE ADAPTER 4 DIP VENT CAP W/SS 6. DI CHECK VALVE MESH SCREEN 6. DI PUJG VALVE 6' DI TEE 9' DI PLUG VALVE(W/RMJ 3 PRESSURE GAUGE (REFER TO SECTION 8 ADAPTERS AS REQUIRED)iN o B FOR CONTINUATION) ADJUSTABLE VALVE BOX. 1 N 225 I r o - TTTYPE PPE 1 I 10'x6' DI REDUCER 1Il1 t° SEE DETAIL 1YP M3 ITT 01 45 BEND U FT D I ( TAO PLAN) (REFER TO PLAN) I 2 90' D U a W HOPE DRI1 RISER PPE WITH 1IY' PVC WELDED JOINTS.FLANGED AT _ CONDUIT FOR PUMP CONTROLS, _ z - EACH END W/SS BACKING RINGS FORCE MAIN QPOWER&FLOAT CONTROLS. HOPE Y PVC FROM MTV VENT(SHOWN ROTATED FOR CLARITY) p REFER TO ELECTRICAL LINER CONDUIT AND WALL SLEEVE SS PUMP CRP-EYE CABLE ZO _ •I SS GUIDE RAIL AND LIFTING SYSTEM PER PUMP MFR INFLUENT SANITARY SEWER W/DROP RECOMMENDATIONS SECTION �B1 Q CONNEC1TON. (SHOWN ROTATED FOR ^ N CLARITY)SEE TABLE ON THIS DWG. 6. HOPE DRI1 RISER PIPE WITH WELDED JOINTS.FLANGED AT �� tz FLEXIBLE CONNECTOR W/316 55 PIPE I EACH END W/SS BACKING RINGS CLAMP AND HOPE WALL SLEEVE INTEGRALLY CAST INTO WALL(TYP) WALL swPMOUNTED S a_ SEE DETAIL 113 a _ I PRECAST WET WELL.PRECAST SEGMENT /,� FLOAT LEVEL SWITCHES JO W 5 (JOINTS NOT SHOWN) ! q pj AND ASSEMBLY SEE DETAIL(TYP) C22 POWER CABLE FROM 1, PANEL BOX 6.X4 DI REDUCING BASE ELBOW W SUMBRSIBLE PUMPS(2 PUMPS •P MPSCIFICATION 11535 I GROUT T.FOORMt PER PUMP MFR'S LIFT STATION ELEVATION DATA(FT) AR 0 FOR MFR AND MODEL No. ID• LIFT STATION I LS-68 I LS-69 1 PROVIDE ADDITIONAL BALLAST AS REQUIRED TO PUMP CONTROL SETTING I PREVENT FLOTATION DURING CONSTRUCTION A: HIGH WATER LEVEL/REDUDANT ALL PUMPS ON 68.7 67.5 BASE EL(SEE TB • • • B: LAG PUMP ON 68.2 67.0 C: LEAD PUMP ON 67.7 66.5 D: ALL PUMPS OFF 63.9 63.0 I.I �j Cl) E: LOW WATER LEVEL/REDUNDANT ALL PUMPS OFF 63.4 62.5 Z • WET WELL DATA UI PREPARE SUBGRADE AND TOP 86.4 84.8 UFOUNDATION ACCORDING TO PUMP BASE BASE 61.4 60.5 (� o B THE CONTRACT DOCUMENTS ���PPPTTT `� INFLUENT SEWER INVERT 69.2 68.0 O B Co G i SECTION (A\ Im C0. 00 p A CERTIFICATE of AUMORVATDN 1641 PROJECT N0: DATE: A DESIGNED U ROSARIO 111 4ES _.. CITY OF ZEPHYRHILLS E1 BY 26110-018-01 FEB 2018 N DRAwN J ALLEN ' .4 UI� JEDMUNDS AIRPORT LIFT STATION AND FORCE MAIN LIFT STATION MECHANICAL SECTIONS PASCO COUNTY FLORIDA ENI T ROSARIO Ilr oWc LW. (WE REVISIONS BY N'PRD CHECKED M CLARK 730 NE WALDO ROAD,LMNENILLE,FLORNA 32641/(3321377-3821 , P.E.P. I 68327 M2 i 3 i PLOTTED: 2/15/2018 12:02 PM JON ALLEN F PROVIDE ROUND POLE r SPAULDING MODEL F ADAPTER TO MATCH POLE CL1S-A-16L1-4K-5M-BL-RPAx FURNISHED OR EQUAL LED FIXTURE WARNING TAPE PER WARNING TAPE PER - CONTRACT SPECIFICATIONS CONTRACT SPECIFICATIONS 15' FIBERGLASS DIRECT \ I / BURIAL POLE II E E PROVIDE WEATHERPROOF 1 \ I7 LIGHT SWITCH AND COVER ; MOUNTED 48" AFG CONDUIT(S) CONDUIT(S) GRADE L OD ' TO CONTROL L i4 PANEL r! ' (TYPICAL ALL UNPAVED AREAS) (TYPICAL ALL PAVED AREAS) PROVIDE 3/4X10-O' GROUND GROUND ROD AND CONNECT o D TO POLE GROUND STUD WITH #4 BARE CU WIRE— D UNDERGROUND TRENCH DETAIL (1 UNDERGROUND TRENCH DETAIL (f\ LIGHT FIXTURE DETAIL( '\ NTS E2 NTS E2 NTS E5 o 0 N GAW910 - TEST WELL BY HARGER, AT ALL PULL BOXES, AND POLE BASES, OR EQUAL ENDS OF CONDUIT SHALL BE SEALED ALL SPLICES SHALL BE MADE ce C Q WITH ELECTRICAL PUTTY AFTER WIRING IN PULL BOX OR POLE BASE rv4c4 o p IS COMPLETED. WITH COMPRESSION SLEEVES OR SPLIT BOLT o c5-'3 PROPERLY TAPED AND CONNECTORS C 0 WEATHERPROOFED. NO. 305 - GROUND ROD CLAMP, BY TRAFFIC RATED PULL BOX, HARGER, OR EQUAL 247x24"x24' DEEP. PROVIDE 12 BED OF PEAROCK AS MANY SECTIONS AS OR CRUSHED STONE NEEDED TO REACH FINAL j /1/0 COPPER FOR DRAINAGE. EGRADE.CCOVER TO SAY = GROUND TRIANGLE CONDUCTOR W I. COPPER CLAD STEEL z O GROUND ROD W U N3 nl NOTE: NOTE: O B PROVIDE 2-2' CAPPED DR FUTURE ON EACH MOUNT TOP OF TEST WELL tLLinwvt�t►fj FLUSH WITH FINISHED GRADE SIDE OF PULL /r FUTURE USE. mFOR FUTURE ACCESS. `\ ` EE CZ ,'y GROUND ROD TEST WELL DETAIL( NTS E5 PULL 'CAI .4o. ".,._/ o = A DEsm M CLARK 1 ' ET ND: OAIE: ONES CITY OF ZEPHYRHILLS FEB 2018 A IIIb�/11 J ALLEN EDMUNDS AIRPORT LIFT STATION AND FORCE MAIN ELECTRICAL DETAILS , • �P. uR. D REVS= B,. Ago OEcRED J OPPOLD 730 NE WALDO ROAD,GA1NESVILL�FLORIDA 32641/(352)377.5821 PASCO COUNTY,FLORIDA L K`:•° _ Rlr oMe N° P. . ii �� E7 PLOTTED: 2/15/2018 12:02 PM JON ALLEN NOTES: 1. PUMP MOTOR CONDUIT SHALL BE SIZED TO MAX 40% CONDUIT FILL. MINIMUM CONDUIT SIZE SHALL BE 2 1/2. ABOVE F F GROUND CONDUITS SHALL BE PVC COATED RIGID GALVANIZED STEEL DOWN TO BELOW THE FIRST ELBOW BELOW GRADE. TVSS UNDERGROUND CONDUITS BETWEEN THE JUNCTION BOX AND WETWELL SHALL BE SCHEDULE 80 PVC ENCASED WITH A AUTOMATIC TRANSFER SWITCH MAIN BREAKER MINIMUM OF Y OF CONCRETE. REFER TO NEC 501.10(A)(1)(a) AND THE EXCEPTION FOR THE INSTALLATION OF THESE METER CONDUITS. ANALOG SIGNAL CONDUITS SHALL BE PVC COATED RIGID GALVANIZED STEEL ABOVE AND BELOW GRADE. ALL 1 PANELBOARD L1 OTHER UNDERGROUND CONDUITS SHALL BE SCHEDULE 80 PVC. UTILITY POWER DISCONNECT 2. INSTALL AN ELECTRICAL GROUNDING SYSTEM IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AS WELL AS LOCAL CODES AND ORDINANCES. INSTALL AN UNDERGROUND PERIMETER CABLE GROUNDING SYSTEM WITH CONNECTIONS TO AT I II LEAST WET WELL COVER, VALVE VAULT COVER. CONTROL PANELS. GENERATOR, UTILITY COMPANY TRANSFORMER. AUTOMATIC TRANSFER SWITCH, AND ANTENNA MANUAL DISCONNECT SWITCH, AND METAL FENCE. 3. THE STATION NAME, PCU I.D. NUMBER. AND ADDRESS SHALL BE AFFIXED TO THE FRONT OF THE METER CABINET. 4. ALL MOUNTING HARDWARE & BRACKETS SHALL BE 316 STAINLESS STEEL. E j E 5. COAT PORTIONS OF ALUMINUM IN CONTACT WITH CONCRETE WITH COAL TAR EPDXY. CONTROL PANEL PLAN VIEW W 1O O .o SU NTPPTD W CONDUIT SEALS (TIP). PROVIDE OUTDOOR LIGHT LISTED SEALING MATERIAL VANDAL-PROOF ALARM STROBE SWITMOTIONCHL YDETECTOR D aD 6 PANEL W/ 3-POINT LOCKABLE HANDLE CONTROL MAIN CIRCUIT BREAKER DISCONNECT TRANSIENT VOLTAGE AUTOMATIC li ALARM UTILTIY POWER SURGE SUPRESSOR TRANSFER HORN (NON-AUTOMATIC) (ASS) SWATCH b Ia AN DISCONNECT K I 3' SS CHNEL 6'x6" CONC POST a STRUT (1W) SEE NOTE o7 PANEL L1 BOND ENCLOSURE 1/2/0, YC. WITH I4 SDBC a CONNECTED TO �0 CONTROL C a J1ll GROUNDING RING UTILITY C 6'x6" CONIC POST CONDUIT, SEE NOTE 1 METER PANEL Er L I I 4' THICK CONCRETESEE NOTESLAB CENTERED AND TO SUPPORT POSE 6O TO PANELBOARD PANEL L1 AROUND PANEL GROUND ROD 4 SDBC TO O. 16" MAX TEST WELL W ' a • e 24'MIN /2/0 TO N = GROUNDING J v RING I.. . . : __ iI] 4TMIN GROUND ROD 6' MIN. I- 0 SET IN CONCRETE z uJ 0 1118' ROUND LONG SWEEP ELBOW TO GENERATOR U B TONG SWEEP ELBOWS TYP INCOMING POWER FROM 0 B ( ) UTILITY POINT OF SERVICE p 10 p i NOTE: EQUIPMENT LAYOUT REVERSED FOR LIFT STATION 168. ,Nnnwro°urnrpr, FRONT VIEW REAR VIEW m ELECTRICAL SERVICE AND CONTROL PANEL DETAIL�1 ;r�•�Q,•��GENSF ...�Q�,,' E-2 u 8 NTS 140 48 98 1O • lg Na h11E: A \A 11ESM M CLARK �ES�/�"'� CITY OF ZEPHYRHILLS fJ 'i-018-01 FEB 2018 MM J ALLEN EDMUNDS AIRPORT LIFT STATION AND FORCE MAIN ELECTRICAL DETAILS owc Na s PASCO COUNTY,FLORIDA E6 owa J OPPOLD 730 NE WALDO ROAD,GAINESVILLE.FLORIDA 32641 1(352)377-5821 •• .• r` L1R. OAtE NEVI90Lrs tr Imo. SIONA� '"rggnuunNnMnnn", PLOTTED: 2/15/2018 12:02 PM JON ALLEN POWER CO SERVICE. CONTRACTOR SHALL INSTALL P-100-..... SERVICE UP TO HAND HOLD AT BASE OF SERVICE POLE F AND COIL 10' FOR CONNECTION BY POWER CO F 30 200A NON-FUSED DISCONNECT LIFT STATION NOTES I 7K SWITCH (COORDINATE WITH POWER CO) 1. PANEL LOCATION IS AS SHOWN ON THE PLANS. P-111 2. CONDUCTORS EXITING CONTROL PANEL SHALL BE TYPE THWN INSULATED COPPER. METER CAN BY INTERNAL CONTROL PANEL WIRING SHALL BE TYPE MTW OR AS REQUIRED BY THE O CONTRACTOR AS REQUIRED MANUFACTURER. BY POWER COMPANY MAST MOUNTED ANTENNA 3. PROVIDE A SURGE PROTECTION DEVICE (SPD) ON THE LOAD SIDE OF THE MAIN P-100 CIRCUIT BREAKER. SPD SHALL BE AN ADVANCED PROTECTION TECHNOLOGIES 3m, 150A SERVICE \� TE/4XT, PO PROTECTION POC100, OR APPROVED EQUAL. ENTRANCE BREAKER 1"C, SEE NOTE 9 NEMA 4X, SS 4. PROVIDE EXPLOSION-PROOF JUNCTION BOX, AKRON AXJ SERIES OR EQUAL, WITH E SURGE ARRESTOR TYPE EYS SEAL FITTINGS FOR ALL CONDUITS SHOWN. MAKE CONNECTIONS OF E IMMERSIBLE CABLE TO PANEL WIRING IN JUNCTION BOX USING TERMINAL BLOCKS DESIGNED TO ELIMINATE THE POSSIBILITY OF ACCIDENTAL ARCING BETWEEN TO GROUND LOOP (SEE NOTE 8) S-102 TERMINALS. PROVIDED SEPARATE TERMINAL BLOCKS AND PHYSICAL BARRIER BETWEEN NG. GIOUNROD (TYP) P-102 5. THE PUMP CONTROL PANEL ENCLOSURE SHALL BE NEMA 4X STAINLESS STEEL FITTED WITH A 3 POINT LOCKABLE LATCH AND DEAD FRONT PANEL. c G i o 150 AMP MIN, 48OV, 3-POLE L 150 6. ALL CONNECTIONS TO THE STATION SHALL BE INTRINSICALLY SAFE AND THE PANEL La P-101 :__s AUTOMATIC TRANSFER SWITCH (ATS) I SHALL INCLUDE, BUT NOT BE LIMITED TO, THE FOLLOWING: (SEE SPECIFICATIONS FOR 1 g SPD, SEE NEMA 4X, SS, SOLID NEUTRAL STANDBY GENERATOR S103 FURTHER REQUIREMENTS) NOTE 3 80 KW, 277/480V, 3� PUMP STATION ATS GENERATOR START CONTROL C103 CONTROL PANEL A. THERMAL MAGNETIC CIRCUIT BREAKERS INDICATED. i m P-103 B. MULTI-STAGE PUMP CONTROL SYSTEM (SEE SPECIFICATION) % SEE NOTE 5 C. CONTROL POWER TRANSFORMERS, AS REQUIRED. C102 SURGE ARRESTOR E. SURGE PROTECTION FOR EACH PUMP. F. HAND-OFF-AUTO SELECTOR SWITCH FOR EACH PUMP. D H. ALARM STROBE AND HORN WITH SILENCEG. GREEN PUMP STOP, RED PUMP RUN LIGHTS FOR EACH PUMP. D ( I. SEAL FAILURE RELAY WITH INDICATING LIGHT FOR EACH PUMP. 6 �150A 3P MCB 480V 240/120V RTU J. CONTROL SYSTEM SHALL BE 120 VOLT. SEE NOTE 10 K. TYPE GFCI 20 AMP, 125 VOLT DUPLEX RECEPTACLE. 60A I L. SUBMERSIBLE LEVEL TRANSMITTER CONTROL. La iT 80A 80A 2P 20A 20A 7. THE CONTROL PANEL INTEGRATED INTERRUPT RATING SHALL BE EQUAL TO THE 3P 3P 1P 1P AVAILABLE FAULT CIRCUIT CURRENT AT THE POINT OF INSTALLATION WITH A MINIMUM --------------------------------------- OF 22,000 RMS SYMMETRICAL AMPS. PUMP O DUPLEX 15A 2 /12 SPD (SEE NOTE 3 CONTROLLER ° RECEPTACLE tP 1 112(G) 8. GROUND ALL ENCLOSURES AND EQUIPMENT IN ACCORDANCE WITH THE NATIONAL bTO R ( ELECTRICAL RODS HALO AROUND THE EQUIPMENT NT PROTECTION TO MINIMUM OF 5 GROUND RESISTANCE OF NOT GREATER THAN 3 OHMS. P-104 S-100 9. PROVIDE ANTENNA, COAXIAL CABLE. ANTENNA MAST AND ALL APPURTENANCES AS P-106 5104 APPROVED BY THE COUNTY AND CONFORMING TO THEIR STANDARDS. SECURE CABLE P-105 C-100 R TO THE ANTENNA MAST WITH STAINLESS STEEL CABLE TIES. ALARM ALARM C C HORN STROBE 10. CONTRACTOR SHALL PROVIDE THE TELEMETRY SYSTEM RTU AND ALL REQUIRED SCADA EQUIPMENT. CONFORM TO THEIR THE TELEMETRY MDSSTANDARDS. BE A S APPROVED BY THE CITY AND c SHALL c CONDUIT C-) SEAL (TYP) a PANEL"L1" a 120/240. NEMA 3R SEE 11111 NOTE 4 LI SS PANELBOARD 9 2P-60 u r4 1P-20 w a (SPARE) P-107 W { N 1 O P-109 S-101 C-101 t — 0 ci B P-108 O B P-110 CoN I I } fi ` 1111/111Urypf/�,,,, WET WELL TYPICAL FLOAT SWITCHES �p���\ t,.EE C AND/ OR SENSORS �(y�jv......�i••�� "�7/ ���iy a110 ����\�•\��N�7�••••��`,'yi= I. No 4 • tt Iq: M7E: A A I>ESKED M cuRK �ES CITY OF ZEPHYRHILLS mqw&-_' F X10-018-01 FEB 2018 II IIII IIIIRANM J ALLEN EDMUNDS AIRPORT LIFT STATION AND FORCE MAIN LIFT STATION 68 ONE LINE DIAGRAM �; , Itr�,�: PASCO COUNTY FLORIDALhR DAN REVOM grOtOCED J OPPOLD 730 NE WALDO ROAD,GNNFSNLLE, LORIDA32611/(352)377-Sl21 ! E3 N ..•r• ssrot4p; .► ttt11N111i11t1111N PLOTTED: 2/15/2018 12:01 PM JON ALLEN I � F I I F I I -N- I I / I „ =�4 4. \- `0 OH POWER BY POWER COMPANY GRAPHIC SCALE10 20 40 E _ SCALE IN FEET �' SEE NOfE 1 I Mao mlo SFr S r_ P-100 �_-_ _,.a5 GRAPHIC SCALE i � •= x� � ��,.� ����� SCALE IN FEET t-: 1.1 y '•' MENT T SPP RESTORATION �� SEE DETAIL C20 -�-'�SF _ SF SF SF —SF SF —"_SFj11 F-4 �ys W aJ I tt z c I p I NEMA 7 JUNCTION BOX 85 -��- O' - - A =4 0f` SEE DETAIL THIS SHEET o I � rj4 _ 1 _Po4. Lrn5, r l ?v SEE�DET L (TYP)I +)fr -' I z \ \ ©1•7 ., ' 80 KW STANDBY d I GENERATOR W/ SUBBASE TANK� SEE SPECS SF ALL WORK SHALL COMPLY WITH ' CODES FLORIDA BUILDING CODE/ I Z oNAL ELECTRIC ZEPHYR oL _B NAME$ Wit. - - - - - - - -< Z `,,,`,� {{Nl/llllllhlfyJl JJ �J >- NOTES AREA DETAIL �```"{' EC C uJ m 1. INSTALL 4"C TO I HH AT BASE OF POLE. COORDINATE W$ POWER CO O��` Vv.. "G •.�qA����i FOR CONNECTION TO SERVICE. ' ��`� �•.°'•ENSF•�'•, 1 ��S. 1 _ j 4SS9 • 1 1 cT Iq are: A �A OE slrt+eo M CLARK CITY OF ZEPHYRHILLS / % `10-018-01 FEB 2018 N oRR.1 J ALLEN IUIEDMUNDS AIRPORT LIFT STATION AND FORCE MAIN LIFT STATION 68 ELECTRICAL SITE PLAN �, • 1 P, Z ` No: o„c W. LiR DATE IlEytlpp5 gF ppj. UE(CKeO J OPPOLD 730 NE WALDo ROAD,GAINFSVILLE,FLORIDA 32647/1352)377.3821 PASCO COUNTY,FLORIDA I El 7 6 14/11 P.E. JJJJJgfJJlii7NefillR{ti{t�ttt`1,,1