HomeMy WebLinkAbout19-21164 CITY OF ZEPHYRHILLS
• 5335-8th Street
(813)780-0020 21164
ELECTRICAL PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit#:21164 Issued: 5/01/2019 Address: 38620 PIEDMONT AVE
Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL.
Class of Work: ELECTRICAL MISC Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 21,800.00 Total Fees: 225.00 Subdivision: ALPHA VILLAGE
Amount Paid: 225.00 Date Paid: 5/01/2019 Parcel Number: 35-25-21-0050-0000-0850
CONTRACTOR INFORMATION OWNER INFORMATION
Name: PALMETTO CLEAN TECHNOLOGY INC Name: HAYNES JAMES & DIANE
Addr: 1505 KING STREET LLC DBA Address: 38620 PIEDMONT AVE
NORTH CHARLESTON SC 29405 ZEPHYRHILLS, FL. 33540-1431
Phone: (707)716-0084 Lic: Phone: (813)395-8454
Work Desc: ROOF MOUNT SOLAR SYSTEM
APPLICATION FEES
ELECTRICAL FEE 225.00
INSPECTIONS REQUIRED
ROUGH ELECTRIC
CONSTRUCTION POLE J
PRE-METER p0 �O
FINAL L �UV 1
-5
REINSPECrION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City
Codes and Ordinances.
CONTRA T PER OFFI
PERMI IRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting 702-716L-0084
owners Name JAMES HAYNES Owner Phone Number (813)788-7777
Owners Address 1 38620 PIEDMONT AVENUE ZEPHYRHILLS,FL 33540 Owner Phone Number
Fee Simple Titleholder Name I Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 38620 PIEDMONT AVENUE ZEPHYRHILLS, FL 33540" LOT#
SUBDIVISION ALPHA VILLAGE ESTATES I PARCEL ID# 35-25-21-0050-00000-0850
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR 0 COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL =
DESCRIPTION OF WORK Roof Mounted solar system.
BUILDING SIZE SQ FOOTAGE HEIGHT
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION
x=ELECTRICAL $. I J�OC)
AMP SERVICE = PROGRESS ENERGY = W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION (
=GAS = ROOFING 0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES NO I -
—— i :-i
BUILDER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N
Address A License#
ELECTRICIANT v v L I�COMPANY Palmetto
SIGNATURE REGISTERED Y/ N FEE CURREK Y/N
Address 150 King St Ext,Ste 114 North Charleston,SC 29405 License#
PLUMBER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREK Y/N
Address I License#
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREK Y/N
Address License#
1111111111111111111111111111111111111111111111111111111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Storrnwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
` NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,600.00 or more,I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone'V'unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INT ND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUlk NaTICE bF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGEN* � TRACTOR
Subscribed and sw to(or affirm d)b fore me this Sub d sw n to or affir )bef°�e me this
by .by y . $3 L 1
is/ a pgrsonally known to me or hasihave produced is/are p rsonall known to me or has/have produced
(� as identification. I as identification.
Notary Public a- )A_2 Notary Public
Commission No. Commission No.
am ti e d r sta/hp€ Nam of Notary typed printed or stamped
r rtyG Notary Public S to of Florida
r Erica Marie McCurdy
a My Commission GG 112270
Expires O6/O6/2021 =o1�t Pu�� Notary Public State of Florida
Erica Matte McCurdy
y My Commission GG 112270
Expires 06/0612021 _
DgcuSign Emvelope ID:0188E296-0506-4052-A70B-570F20BB6501
Envirosolar
Purchase Summary
Contractor Name: EnviroSolar
Customer Names: James Haynes
Purchase Date: 2/5/2019 1 2:47:39 PM CST
Itemized List of Purchased Products and Services:
1. 4.13 kw system
2. 0 solar attic fans
3. 1 Energy Management System
4. 50 LEDs
5.
6.
7.
8.
9.
Total Purchase Price: 21800
THIS PURCHASE SUMMARY DOES NOT CREATE A BINDING AGREEMENT BUT SOLELY IS A SUMMARY OF THE
BINDING AGREEMENT WHOLY CONTAINED IN THAT CERTAIN SALES CONTRACT OF EVEN DATE BY AND BETWEEN
CUSTOMER AND CONTRACTOR.
DocuSigned by:
Customer(s): ,;;(s (ka Vxs
803OA934771MB2...
Contractor: EnviroSolar_
By: Ffocuftned by:
r AUV. i M
W uur DBO i 4AC...
Name: Trevor Monci bai s
YOU, THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF
THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. SEE THE ATTACHED
NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT.
Enclosure:Three Day Cancellation Notice
DATE: March 15,2019
RE: 38620 Piedmont Avenue, Zephyrhills, Florida 33540
To Whom It May Concern,
As per your request, we have conducted a structural assessment of the building at the above
address that included a site inspection on March 8,2019.This inspection included an examination
of the roof structure and condition as well as any structural drawings that were available.
PV solar panels are proposed to be installed on roof areas as shown in the submitted plans.The
panels are clamped to rails which are attached to the roof with a lagged mounting system, and
installed per manufacturer's specifications and recommendations.
It was found that the roof structure as noted on S3 satisfactorily meets the applicable standards
included in the FBC 2017 61h Edition,2015 IBC/IRC and 2018 IEBC.
Design Criteria:
Wind speed = 137 MPH
Ground snow load =0 psf
Roof dead load =9 psf
Solar system dead load =3 psf
The roof was determined to have asphalt shingles atop half-inch plywood sheathing.
Overall the roof area is structurally adequate to support the additional load of the solar panels
and,their framework.
,p��uuurn4rr
Acknowledged by: O`ON
"A215
by
signed No.81142 s
Chris by Chris H Kim E
'Date: =
2019.03.15 Q •. EH K•m-
P
'15.46:32-0400
Chris Kim, P.E. � AL
r
r
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
� E
Contractor/Homeowner:Date Received: Yh
Site: �0,6 ye, '
Permit Type: p O V jr)���
Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑
This comment sheet hall be keXpaitli the permit and/or plans.
Kalvin itzer—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
INSTR#2099056764.OR BK 9884..PG,3807 Page 1 of 1 ,
a 04/04/2619.12:10 PM Rapt::2043010 Rec: 10.00 DS:0.00 IT:0'.00
Paufei S. O'NeiC Ph.D.,Pasco County Cf&k&Cbntptroller
Perrirll No. Parcel ID Na.3S•25.214050.000DO-0860
NOTICE OF COMMENCEMENT
FLORIDA .
Sbte
of Count'of PASCO.
THE UNDERSIGNED her paves notce That improvement wdD De mode to CQrfAtt teal property,end ki accordance vrtth Chi p[er 713,Florida Statutes,
the foIIovdnp thiortnedon la provded In this Notice of Commencement
1. Description of Prop art-..Parcel ldentifiagon No.3f2S210054C090o-ea50.
Se tat Address:-38620 PIEDMONT AVENUE ZEPHYRHILLS,FL 33540
2. General Description of improve.ment
INSTALLATION OF ROOF MOUNTED PHOTO VOLTAIC SYSTEM'
3, 'Owner Intoenatlyn or Lessee Information it the Lessee eenbaded for the linprovemont
JAMES&DIANE HAYNES
>aaw¢ao.+aona. Name ZEPHYRHILLS FL' .
AdQ ass City State
Interest In Property:.OWNER"
Name of Fee Slmple Titleholder
fit-different from Owner listed strove):.
Address Gry - State
4: Contractor:
Name
rrasrcardox� North Charleston'_ SC,
'Address City. State:.
Contrecto/sTclepboneNo'.t 8437201844
• 8. 6woty: ,
Name ,
` Address city. State' =
Amount of Bored;-S Telephone No.:.
8. Lender
Name
Address City_ State
Comdata Telephone No.:
7. PorsoM within the Stela of Florida designated by the owner upon whom notices or other dowmanls may ba sorvod as proV.ded by
Section 713.13(1)(e)(7),Florida Statutes:
Name .
Address . . City State `� ~ UIt'
Telephone Number of Designated Pareon t4 W-lL ' U
U � � U— —1
8. In addition to himge8,the ovmer designates of_ O �
to rece)va a copy of the Uenor i Notice as provided In Section 71 rid 3.13(1)(b),Floa Statraes. Q U '<..N O
:Tele hone NumW of Person or
P ErSy Deslpnated by Owner_ L .p F E
w U.)a W.
8. Expiration date ofNotice of Commencement(the expiration dab may not ba before.the domplotan of constriction and final payment io.tho W
jE
eonlra ior,[cot v.0 be one year Irarn the dale of recordiI.ng uNesa i ddfammi Este is specified): O 5, V
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT.' lJ1 O�'•—
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713.PART 1 SECTION 713.13 FLORIDA,STATUTES..AND CAN ' }:W'LL
RESULT.IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROARTY. .A NOW69 OF COMMENCEMERF MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION,IF YOU INTEND TO OBTAIN FINANCING,CONSULT 0 1- d a O'
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.' V S 00 Cr W'.
Ungar penally of per)ury;I declare I mt 1 have read thi foregoing notice of commenearnonl and that the fads stated therein era trite 10 the best
of my knowledge and belleL 0 m V
STATE OF FLORIDA LLI �Z O J
COUNTY OF PASCO �� lei W
Signs fownerar ssee,or erL essedsAuthorized W'O O 0_
0 odl dl or/PaMsr/Managor U () �.
lZ
bw+.i dy. . .0 o 0
SignatorysTmerofka LLI fn¢Lif
cw� • W _j UJ
fieum foregoing Instrument was ada W towfedged before me s .!' day of 20 ft by. 0'$4FC cn=_.-)I
of -'0"3 . of only,a.g.,outer.tru tee.adbmay in tad)for
s 1
Z
_� ( _ IM
pa baheM c o m Instrument eras executed). r ~ O
v �
Perso4!ly Known[3 9E Produced ldentificati-on Lzl' Notary Signature G��G • 'a
Type of ldontMcation Produced- L V4 Name(Primp
o ar-•zy_i4•uts•ubtit:Stile tit Fbrid 0 �%' .-S' ,s ':�� �
rea11Y P..
-E MaAa/AeCutoY oo
t' ylCot11m1ubn t30172270 .� r •, C Dy Ina 0810ed2DZ1 xf`/y.
N9dala/bWnollccmmmenearrtenL,pc053040
I Power Optimizer
ForNorthAmerica
P320/P340/P37/P400/P405/P5
_..
Alwk�etpixxrlyrt �,
*} U #7 A k
w.w�Arae saw us Ps nac
Ar uus x
al a6 Iwt
1►44 +, 1
w � �
14iiw/�xni�lrx
At 11 l�Iltirs111f
aisalaz$I t2$i slat 22$ ilix>Zt
CMM�M�O�l4WIII2$ t sa i22 afsxs,Iu Sxs,$:Ln SiclrLai Sxs$ 2a rwti
SLIM 722117 3*11.2 1N$I2J tit
wM aarriwirtcra
3 I Utti stit
t1sl1ts7 rti
ar PV power optimization at the module-trod
•
• I Vuft t didto wort with SolsEdpe ! F ban wRh a side bolt
Irwaftrs
It _Rh nnodde-
Up bo 2914 mare eneer iced
I Supecbr 1 td s1 G re crtsior arc tavlt
w« ar+ttcrar► n ss P and PbQtwj0Rair Rapid
Mibrs aR types of nm*ie ni loses,
w.r .wr..assrro s or+cc- smr aaxs w *ate nman�aacrrinp tolerance do p[rtiei
I IW0dule-lard voltage 3hmb$own tar i aRer
> s
I fiedble syi deslyn icx m drown space
•Ar t �rrsw+�ir�r�rsrrp7S+SarrAw
+M�I+iN►1n1�Fi�rrtrrwlNrrwr#111i1+n+R
sole " z
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE A5-OPTIMIZER SPECIFICATIONS
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
\`��� WWW.PALMETTO.COM CLIENT:J. HAYES REV:-
solar • • •
Single Phase Inverter
solar ' e with HD-Wave Technology for North America
SE3000H-US/SE3800H-US I SE5000H-US/
Single Phase Inverter SE6000H-US/SE7600H-uS/SE10000H-US/SE11400H-US
with HD-Wave Technology •
for North America SM 6°e %00 = 0 1140 VA
SE3OOOH•US/SE OOH-US/SE5000H•US/ i .ACpowshra phA 3Qoo �: "°"' Sw s000�24ov 7sao 10°°°.,. 11400 VA
kahrphht i f .. f vx
SE61 H-US/SE760OH-US/SE1OOo0H-US/SE1140OH-US .... NomrFAhnc '
AC Output ftItaie Mn-Nor;:Max, / / .r ✓ ✓ / v:
ACFrsquency(Nominail ... ....... 583-6060.5 _•., i!z ...
lulii�n urn ccl thuot5 Output Current
16 2°...... ......:........ A
CY ......:.............................. ............. . ..... ..... _...,....,.,.. .., .,,....... .....47..S ..,.. .
CohtlrNhatr3Outp t 12S Y6 21 .. 3242 47S A•{ fF0IYltresi!oid... _........ ................ .. ...... .. A....
1j • t,N l'Moil andin4 Protectlon. lBes
MiodnwtrhW:Powar 240Y 4650 X00 T750 • 9104 11800 15500 37550 4V
WlnhimunsOtpawer•Zdfft 5100..... ............. 7710 .... .............,. ,... ......... . .......,.
s .. lies.
Maximum.h ............ .......................... . ... ' .100 .. .......PmmaIhtVolte .3oi .. • Mndrthurn Mhut Chure�t 208V „ - 9 13S - .. ..
i
Ma�dmun Currerht 2A0Y ..BS.. ..RU.S. .13.5.. 16.5 2Q.. 27
.:...... ............... .... . .. . ... .....:.. . ..... ..... :... .... .. , ,, .
y.4ne���a .T!NCMM! ..... ............... ................ ...r .... ...........,.. .............. ,.,...x w.
atlpoeeh ........ .. ... jj ..... ..... ....a .:...x. '• ......w.,,,. .. ..,a.,............,...... wa
- Mikhrll11111(IY'lfTer C•".-.`. . ........ ..... ......3 99.3 .......... ......,........,..,,............ % ..,
• c. a.............. ........,....... ...a . .... ... . ,...a..,,.,..... .......;..,,,.>,. .,....,....... .a
for Consu <2 3 w
SupcortedGorernu ionlMerfaces.. 85485 Ethernet. ee(o*Iona).Cellular{oplbrai�...,.......
ReMeehyp. ....R ta..ANSI12.2) . . ., ,..... h n
Rapid Shutdown-N 2014 and 2017 ........... .... ............ .. .
Autmudc RWW Shutdosrtn upon AC Grid Obcomed
Sit . ...... ................. ......x.w...a...UL1741.uu7ex SA,ut 1699ew,C5A C22 Zr cans an AFcl accord to TI L M- 7
cdcomer{onsearas............... ............, .. .x.a... EYsa,au+e1iieil..,..,,. ... . ......a.. .............. ........
Ehrhitsi4ns FCC Part 15 Class
ac Output or! sme fawn atp ...... ..........3a"mMdmaera/14.6 AW ..... ............... ,.Y4•rw, wn,/Y-4 Aws
Drdu.tSinejiofark 3�4'rthkhiarnam/i3stdrags
3<4" +m/13 strk+gs J 14..AwG
........ ....I........... .... ... ...... ... ... ........ ...........
Wmensions with Safety Switch(NxWxD) 17.7x 14.6x6.8/450 x 37Dx 174 21.3x14.6:7.3/540x370 in/mm
...... .
Wenightwhh5afetySwch 22/10 I 251!114 I 26,2/11.9 ....,... 98(176 /kd
25 d8A
...Noise ..,
kN6 ............. ................. ......IlstwaI ortyectlaxh ...... Natural con ectlan
.....
-4a'copaon�".............'..; .... .. ,....... .Fc.,
Prot on.lgtlni... ... ... ..I+EMA t{inwertw wNh 5atetY riDch�
uhwaar..de.ut ptwa------.a«E4rNOW
w�e...rhre:Iw
www.solaredge.us
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE A4-INVERTER SPECIFICATIONS
PHONE: +1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
WWW.PALMETTO.COM CLIENT:J.HAYES REV:-
IIIIIIIIIIIUIIl
I_ ♦ �� • i � Ali • # r 1
I iii 1T
w ,_ 6 i.1I4i1.I
IJ1 ■
W !R
iii-.■L:SiJi 1 ;_,h'_1I' i tv
�.�®iii `: .tip► ;rtt,
►�I it :.'l;i I ( * :...
8NAPNRACK,STANDARD RAL DRyan SflaINvodç
- REVISION: tifl S1UU
232-01067,232-01068,232-01069,232-01070, J .�
232-02112,232-02113
Ir
_______ B JJ7Jr
44
ALL DIMU6IONS IN V
MA1 1ALS: 6400 SERIES ALUMINUM OPTIONS:
DESIGN L (LES): WA /I
ULTIMATE LOAD(M: N/A MILL FINISH
TORQI SP JLTION: N/A LOFT 12?!16?LE
CERTIFICATION: UL 2703,FU.E 059313 BOXES OF 216
WEIGHT(1.68): 7.65-10.16 BUNDLES OF 112
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE A2-RACKING SPECIFICATIONS
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19
WWW.PALMETTO.COM CLIENT:J. HAYES REV:-
{
Test talons NOCT
Module Per 227
24
`pmt ttwer V g
t..
Alat�tum curatt A 769
OpedrtvItjge V
369:
# Short draua currant A 736
MoA�e s *13
V
edesfuse r A
Tolerance wp 01+5
r ► moa,iatror � a w •wurris+�ss
1 lsc %/K
T CoafldettVoc %lK
Te aetecoeflidentPtnax WK
100%MAXIMUM POWER DENSITYl t:T r 45
Silfa&s SEAM 300 ultra-high-efficiency p Ic
modules are optimized for both Residential
and Commercial projects where maximum
power density is preferred• Module t
• It Qmertsions(H x L x D;t 1 mm 1650*990x
100%NORTH AMERICAN Maximum surfaEeioad tainelsn M'' Nh
QQUAUTY MATTERS " tF rtxrt x s km/h
Silfab's fuily automated manufacturing facility teas
._._
ensures precision engineering is applied at 3.2 rhm hipt a a stnibtattce� atttir ve costirt
every stage.supelor reliability and performance -based
combine to produce one of the highest #rra me,
quality modules with the lowest defect rate 3 dlod iiJ12M tP67JiF
in the Industry, t':ahies and cars#see tnA Lion cr,a j
NORTH AMERICAN Module productttiarraoty
CUSTOMIZED SERVICE
jl Silfab`s 1tl0%NorthA nerlcan based teamLkear power perfc.mance> ≥90%endorI2yea
leverages just-one manufacturing to deliver
service on-time delivery and :a of25•year
tlexittle prt�at solutktns.
UtC ORDC1.703,Ut 1743.IEC 6121$,lE 61730,IEC61701,CEC listed
Product1 UL Fire Retir2f Ion recpj
LWanilng Read Uie lnstallaUon and User Manual before _____________
hen Mistat tg and modules
Tlfrd-partygenerated panfNes from 'm
PVEvolttlon tabs available g
far do en lcad oavaa
*Pa$et Cwutt 26
Contains'Gaunt 936
a
�lwwsar
4J )
56fabSolar Inc. ..�...�...
24CCow wparkDdveE.'s+fi aug& "
1j 0rft oC.anaaatsT2 r
Tel+1905.256.2501'Fax+1905-696-0267
-wNrsEab.ca
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR:EE Al -PANEL SPECIFICATIONS
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
WWW.PALMETTO.COM CLIENT:J. HAYES REV:- I
1
FORMAT
1.WHITE LETTERING ON A RED BACKGROUND
• 2.MINIMUM 3/8 INCHES LETTER HEIGHT
3.ALL LETTERS SHALL BE CAPITALIZED
ELECTRIC SHOCK HAZARD 4.ARIAL OR SIMILAR FONT(NON-BOLD)
TERMINALS ON BOTH THE LINE AND LOAD SIDE I I I [NEC 690.13(B)]ALL AC DISCONNECT SHALL BE MATERIAL
MAY BY ENERGIZED IN THE OPEN POSITION LABELED REFLECTIVE,WEATHER RESISTANT MATERIAL
TURN RAPID SHUTDOWN SUITABLE FOR THE ENVIRONMENT(USE UL-969
SWITCH TO THE"OFF" AS STANDARD FOR WEATHER RATING).
[NEC 690.131 PLACE THIS LABEL ON ALL POSITION,TO SHUTDOWN I • • • • A DURABLE ADHESIVE MATERIALS
DISCONNECTING MEANS WHERE CONDUCTORS OUTSIDE
ENERGIZED IN AN OPEN POSITION THE ARRAY.
CONDUCTORS WITHIN
ARRAY REMAIN
ENERGIZED IN SUNLIGHT [NEC 690.13(B)]ALL DC DISCONNECT SHALL BE
LABELED
PHOTOVOLTAIC • 46o vDc
J POWER SOURCE [NEC 690.56(C)]PLACE AT MAIN SERVICE PANEL 15 AMPS
[NEC 690.31 (G)3&4]PLACE ON ALL JUNCTION PLACE THIS LABEL WITHIN MAIN SERVICE DISCONNECT(OR ON OUTSIDE 15 AMPS
BOXES.EXPOSED RACEWAYS EVERY 10' DISCONNECT OF OPERABLE WITH COVER CLOSED)
[NEC 690.53]PLACE AT EACH DC EQUIPMENT
DISCONNECTING MEANS
j •
ui
♦ II1mnh',
[NEC 690.54]PLACE LABEL AT"INTERACTIVE +�* � '." rrrs
*
POINT OF INTERCONNECTION"(AT MAIN �` Q N $1142 ".
SERVICE PANEL AND SUBPANEL IF APPLICABLE) t 9
CONTAINS MULTIPLE j': ST £
POWER SOURCES '% ip'`=•'
[NEC 705.12(D)3]PLACE LABEL ON ALL QL "
{ EQUIPMENT CONTAINING OVERCURRENT D
s !!
DEVICES IN CIRCUITS SUPPLYING POWER [NEC 690.56(C)]PLACE NO MORE THAN 3.3FT
TO A BUSBAR OR CONDUCTORS SUPPLIED FROM SWITCH
FROM MULTIPLE SOURCES
NOTES:
1) ALL LABELING USED OUTDOORS MUST BE ENGRAVED METAL, UV STABILIZED ENGRAVED PLASTIC OR OF A MATERIAL SUFFICIENTLY DURABLE TO WITHSTAND THE ENVIRONMENT INVOLVED. VALUES HAND WRITTEN OR IN
WRITTEN IN MARKER ARE NOT ACCEPTABLE PER NEC 2017.
2) LABELS USED INDOORS MAY BE MADE OF DURABLE VINYL OR PAPER
3) DO NOT COVER ANY EXISTING MANUFACTURER APPLIED LABELS WITH INSTALLA11ON SPECIFIC LABELS
4) LABEL COLORS CHOSEN PER NFPA 70 2017 DIRECTION THAT ANSI Z535-2O11 BE USED
5) REQUIREMENTS COMPLY WITH NEC 2017
6) ADDITIONALLY, IT IS HIGHLY RECOMMENDED THAT THE INSTALLER ATTACH A LABEL WITH THE COMPANY NAME AND CONTACT INFORMATION AT THE INVERTER
7) ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(6)
{ PALMETTO
PROJECT:38620 PIEDMONT AVE AUTHOR: EE E3-WARNING LABELS
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
WWW.PALMETTO.COM CLIENT:J. HAYES REV:-
SYSTEM SUMMARY
STRING 1 STRING 2 STRING 3
POWER OPTIMIZER MAXOUTPUT CURRENT 15A N/A N/A SOLAREDGE MAXSTRING SIZE
OPTIMIZERS IN SERIES 14 N/A N/A MODEL SE38WH-US
ARRAY STC POWER 4200W MAXSTRING POWER 5700W
MAX AC CURRENT 16A PMAX PANEL 300W
NOMINAL AC POWER 3800W MAXSTRING SIZE 19
MODULES
QUANTITY MAKE AND MODEL PMAX ISC IMP VOC VMP TEMP COEFF OF VOC FUSE RATING
14 SILFAB SLA-M 300W 30OW 9.71A 9.16A 39.85V 32.80V -0.30%/°C 15A
POWER OPTIMIZERS
QUANTITY MAKE AND MODEL RATED INPUT POWER MAX OUTP UT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY
14 SOLAREDGE P320 320W 15A 11A 48V 988%
INVERTERS
QUANTITY MAKE AND MODEL AC VOLTAGE MAX OCPD RATING RATED POWER MAX OUTPUT CURREI�I'F MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED
EFFICIENCY
1 SOLAREDGE SETH-US 240V 50A 3800W 16A 10,5A 480V 99%
OCPDS OCPD SOLAR BREAKER CALCULATION
QUANTITY RATED CURRENT MAX VOLTAGE MAX OUTPUT CURRENT NEC MULTIPLIER MIN OCPD SOLAR BREAKER
1 20A 240V 16A 125% 20A
ID CONDUCTOR CONDUIT #OF CCCs IN CONDUIT* OCPD EGG CONT. CURRENT MAX CURRENT
1 10 AWG PV WIRE, COPPER FREE AIR N/A N/A 6 AWG BARE, COPPER 15A(PER STRING) N/A
2 10 AWG THWN-2, COPPER 0.75" DIA. EMT 2 N/A 10 AWG THWN-2, COPPER 15A(PER STRING) N/A
3-4 10 AWG THWN-2, COPPER 0.75" DIA. EMT 2 20A 10 AWG T WN-2, COPPER 16A 20A
ID CONDUCTOR BASE. AMP FILL FACTOR DERATED AMP. TEMP. FACTOR** TEMP. DERATING ' +�r
2 10 AWG THWN-2, COPPER 35A 1.00 35A (1.96 33 6A . .«,...* .
3-4 10 AWG THWN-2,COPPER 35A 1.00 35A 0.96 33.6A ��El1►s •. .
*CCCs REFERS TO CURRENT CARRYING CONDUCTORS a �
"TEMPERATURE FACTOR IS BASED ON 2% DRY BULB HIGH WITH NO TEMPERATURE ADDER THEREFORE RACEWAYS MUST BE AT LEAST 7/8"ABOVE ROOF
PALMETTO
PROJECT:38620 PIEDMONT AVE AUTHOR. EE
E2-ELECTRICAL CALCULATIONS
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
11� WWW.PALMETTO.COM CLIENT:J. HAYES REV:-
BI-DIRECTIONAL UTILITY METER
•� ,•'• 4 TO BE INSTALLED BY DUKE ENERGY
No,81142
.�• �, E �g L7 L2
i sir �'•,• ,t +�*
MAIN SERVICE PANEL
�!i# •�•••+,r+ 240/120 V 10,3W,150A
MAIN
1S0A/2P
(E) 0 LD (E)
(E)
® (E)
VISILE
LOCKABLE B MAIN (E) ® (E)
SERVICE
DISCONNECT (E) (E)jE
INVERTER 1 240/120 V 10,3W
SOLAR EDGE SE3800H-US 3 20AF/30AS 4 (E) ui (E)
WITH DC DISCONNECT,NEMA3R NEMA3R
JUNCTION BOX (E) ® (E)
1 STRING OF 14 MODULES EACH NEMA3R
CONNECTED TO P320 OPTIMIZERS 1 240V (E) ® ® (E)jE
Lç (N)2oArzP (E)
DC+ • DC+ O
0� DC ono SOLAR BREAKER LOCATED
® AT THE FURTHEST END OF
EGC BUS BAR FROM THE MAIN
G G
BREAKER OR FEEDER UNIT
EGC G
GEC
PHOTOVOLTAIC SYSTEM GROUND
EQUIPPED WITH RAPID ROD
SHUTDOWN,INTEGRATED
DC DISCONNECT&ARC
FAULT PROTECTION
INVERTER SPECS MODULE SPECS ASHRAE AMBIENT AIR SPECS OP11MI2ER SPECS
MAKE: SOLAREDGE TECHNOLOGIES LTD. MODULE MAKE: SILFAB SLA-M 300W 2% DRY BULB TEMP: 92.8°F MAKE: SOLAREDGE TECHNOLOGIES LTD.
MODEL: SE3800H-US MODULE QUANTITY: 14 MODEL: P320
MODULE POWER. 300W DISTANCE ABOVE ROOF (> 7/8"): 92,8°F
INPUT INPUT OUTPUT
MAX INPUT VOLTAGE: 480V VOC: 39.85V VMP: 32.80V EXTREME MINIMUM: 12.7°F MAX VOLTAGE 48V 60V
MAX INPUT CURRENT 10.5A ISC: 9.71A IMP: 9.16A MAX CURRENT 13.75A 15A
MAX DC POWER: 5900W WIRE SCHEDULE
ID CONDUCTOR NEUTRAL EGC CONDUIT KIT
OUTPUT 1 (2)#10 AWG PV WIRE, COPPER N/A (1)#6 AWG, BARE, COPPER EGC N/A FREE AIR
NOMINAL AC POWER OUTPUT: 3800W 2 (2)#10 AWG THWN-2, COPPER N/A (1)#10 AWG, THWN-2, COPPER EGC 0.75" DIA. EMT
NOMINAL AC OUTPUT VOLTAGE: 240V 3-4 (2)#10 AWG THWN-2, COPPER (1)#10 AWG THWN-2, COPPER (1)#10 AWG, THWN-2, COPPER EGC 0.75" DIA. EMT
MAX OUTPUT CURRENT: 16A
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE El -LINE DIAGRAM
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
WWW.PALMETTO.COM CLIENT:J. HAYES REV:-
Materials included-L Foot Fk tdng Kit
.(0 LF.a5
•rn••. ad*000."'._L
•mvw- n w@"a'!wg
•
LAG SCREWS SHALL
Other Materials Required
tl n
eov'rwor..
BE S.S. 5/16 X 4 W/
2.5" MIN EMBED IN
r RAFTERS/TRUSS TOP
CHORDS
TOP CHORD °'~ "�
TOP CHORD
2x4 @ 24" O/C
in
WEBBING
2x4 @ 24" O/C
BOTTOM CHORD
2' f 12'-4"
ROOF 1 uIni ,,,,,
f' .<$CEN ..
3 No.81142
* - MAX. 48"
`*. ST E . TOP CHORD SPACING: 24"
MAXIMUM MOUNT SPACING: 48"
MOUNT PATTERN: STAGGERED
rSCALE-.NTS
PANEL TYPE: SILFAB SLA-M 300W NOTES:
PANEL SIZE: 65.0"x 39.0" - SCALE AS SHOWN
RACKING TYPE: SNAPNRACK 100 - ALL DIMENSIONS IN FEET UNLESS
MOUNT TYPE: SNAPNRACK FLASHED L FOOT
OTHERWISE STATED
SOLAR SYSTEM DEAD LOAD: 3.0 PSF
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE S3-STRUCTURAL DETAIL
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19
mo WWW.PALMETTO.COM CLIENT:J. HAYES REV:-
S
I .
f - -- 48'-7" -
CABLE
(MOVABLE); :; u
i % ��//// /
/ // ////i
/ iii/////// //�
///ii //ii X/ i////ii it//!/ir/ /i/ii/� �t
Iii//ii%i/viii�'//iiri/✓��fii 1 ._ �i//��iii/��ii!/''viii�/////��iiii� i�
VET BOX
///�/✓////i/iii iii
PVC VENT
10"TYP
4'-64' / / uuu
LEGEND
ROOF 1 a .•w�GE�sF��: , ,
TOP CHORD PITCH 18.5° Na81142
AZM 182
METER STATE .'• 3
FIRE ACCESS ¶ 4P' /
PATH
DECIDUOUS TREE
DECIDUOUS TREE
A�-
FIRE TREETOP 29' 1
VENTILATION TREETOP 26'
CANOPY 15' CANOPY 15'
I SCALE: 18 I
ROOF PITCH: 18.5° SLOPED SHINGLE ROOF PANEL TYPE: SILFAB SLA-M 300W NOTES:
AZIMUTHS: 182 DEGREES PANEL SIZE: 65.0"X 39.0" - SOLAR PANEL LAYOUT SUBJECT TO CHANGE ACCORDING TO
III RACKING TYPE: SNAPNRACK 100 NUMBER OF PANELS: 14 EXISTING CONDITIONS
MOUNT TYPE: SNAPNRACK FLASHED L FOOT SYSTEM SIZE:4.20 kW - SCALE AS SHOWN
GROUND TO EAVES DISTANCE: 8'-3" - ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE S2-PANEL LAYOUT
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19
t\ WWW.PALMETTO.COM CLIENT:J.HAYES REV:-
I
PIEDMONT AVENUE
f___ 73'-8<" __
38620 PIEDMONT AVE
✓ 48'-8z" ,r
DWELLING N.
WALL INVERTER w/WARNING LABEL
AC DISCONNECT w/WARNING LABEL
SERVICE POINT & UTILITY METERING
N DISTRIBUTION PANEL w/WARNING LABEL
of Vii„
O)
Lii
z
•�f•rrG rr�f
f {�
f • �
• Digitally signed
38620 PIEDMONT AVE C i i Chris by Chris H Kim
DWELLING ate:
H K' x.15
15:45:47-04'00'
I SCALE: 1" 18'
NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY
j - SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME:
- ALL DIMENSIONS IN FEET UNLESS - INSTALLERS SHALL UPDATE NAME,ADDRESS,AND PHONE NUMBER OF ADDRESS:
OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING PHONE NUMBER:
WORK
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE S1 -SITE PLAN
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19
j ," WWW.PALMETTO.COM CLIENT:J.HAYES REV:-
GENERAL NOTES:
III
ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE
CODES:
IBC 2015, IRC 2015, IFC 2015, NEC 2017 • WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION,THE BREAKER SHALL BE
• PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER STRUCTURE IN ADDITION TO ANY INSTALLED AT THE OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER.
OTHER ELECTRICAL SUPPLY SYSTEM(S)[NEC 690.4(A)1 • TO REDUCE FIRE HAZARDS, DC PV SYSTEMS WILL BE EQUIPPED WITH A GROUND FAULT PROTECTION
• THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE SYSTEM IN ACCORDANCE WITH NEC 690.41(B)
PERFORMED ONLY BY QUALIFIED PERSONS[NEC 690.4(C)] • WHERE GROUND-FAULT PROTECTION IS USED,THE OUTPUT OF AN INTERACTIVE SYSTEM SHALL BE
• EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS,VENTILATIONS INTAKE AIR OPENINGS CONNECTED TO THE SUPPLY SIDE OF THE GROUND FAULT PROTECTION[NEC 705.32]
SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. • ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL
• INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS,AC SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE
PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT.
USE IN PV SYSTEMS SHALL BE LISTED OR FIELD LABELED FOR THE PV APPLICATION [NEC 690.4(B)] • ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS,AND LABELS SHALL BE POSTED ON EQUIPMENT
• ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED(OR BETTER), INCLUDING ALL ROOF MOUNTED AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT.
TRANSITION BOXES AND SWITCHES. • CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY
• ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED"DO NOT
• SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 DISCONNECT UNDER LOAD"OR"NOT FOR CURRENT INTERRUPTING". [NEC 690.33(C)&(E)(2)]
• FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL COMPLY WITH • FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES, OR
NEC 250.120(C)[NEC 690.46] CONNECTORS IN ACCORDANCE WITH NEC 110.14
• ALL PV SYSTEM DC CIRCUIT AND INVERTER OUTPUT CONDUCTORS AND EQUIPMENT SHALL BE • WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1),
PROTECTED AGAINST OVERCURRENT UNLESS STATED OTHERWISE IN NEC 690.9(A) 110.26(A)(2)AND 110.26(A)(3).
• OVERCURRENT DEVICES USED IN PV SYSTEM DC CIRCUITS SHALL BE LISTED FOR USE IN PV SYSTEMS • ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET
LOCATIONS PER NEC 314.15.
[NEC 690.9(B)]
• PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN • ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED&IDENTIFIED IN
ACCORDANCE WITH UL1703
ACCORDANCE WITH NEC 690.12 • EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S
• DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE REQUIREMENTS.ALL SOLAR MODULES, EQUIPMENT,AND METALLIC COMPONENTS ARE TO BE BONDED.
PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(Aj] IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER
• ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING
• CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED"DO NOT DISCONNECT UNDER LOAD" ELECTRODE.
OR"NOT FOR CURRENT INTERRUPTING". [NEC 690.33(E)] • DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC CIRCUIT'OR EQUIV.
• ALL GROUNDED CONDUCTOR SHALL BE PROPERLY COLOR IDENTIFIED AS WHITE. [NEC 200.6] EVERY 5 FT.
• CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER.VERIFY
• PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER
SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE.
SOURCE(S)AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING[NEC
705.12(B)]: • SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM.
1) EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE • ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS
DISCONNECTING MEANS. [NEC 705.12(B)(1)] REQUIRED PER NEC.
2) THE SUM OF 125 PERCENT OF THE POWER SOURCES OUTPUT CIRCUIT CURRENT AND THE RATING OF
THE OVERCURRENT DEVICE PROTECTING THE BUS BAR WILL EXCEED THE AMPACITY OF THE BUS BAR
[NEC 705.12(B)(2)]
3) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR
CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [NEC 705.12(B)(3)]
4) CIRCUIT BREAKER, IF BACK FED, SHALL BE SUITABLE FOR SUCH OPERATION. [NEC 705.12(B)(4)]
PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE N1 -GENERAL NOTES
PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19
WWW.PALMETrO.COM CLIENT:J. HAYES REV:-
4tF RESIDENTIAL SOLAR
PHOTOVOLTAIC SYSTEM
a
38620 PIEDMONT AVE
0C,I ENERGY
ZEPHYRHILLS, FL NEW AGE ENGINEERING
4.20 k v V DC +1 833 392 2887
14/MAR/ 1 9 208-888 DUPONT STREET
PALMETTO E17O TORONTO,ON
+1 843-720-1844
1505 KING ST EXT#114,
CHARLESTON,SC 29405,USA
SHEET INDEX
Cl COVER PAGE
NI GENERAL NOTES
S1 SITE PLAN
S2 PANEL LAYOUT
S3 STRUCTURAL DETAIL
El LINE DIAGRAM
E2 ELECTRICAL CALCULATIONS
E3 WARNING LABELS
Al PANEL SPECIFICATIONS
A2 RACKING SPECIFICATIONS
A3 MOUNT SPECIFICATIONS
A4 INVERTER SPECIFICATIONS
A5 OPTIMIZER SPECIFICATIONS
SYSTEM SPECIFICATIONS GOVERNING CODE:
ING SYSTEM SIZE:4.20 kW IBC 2015
ALL WORK s A Bu M W"V* ' 172019
CODES FLOR MODULE:SILFAB SLA-M 300W IRC 2015
DIALCECTRIC CiTY OF INVERTER:SE3800H-US IFC 2015
ORDINATES .A1S EXAMINER OPTIMIZER: P320 NEC 2017
RACKING SYSTEM:SNAPNRACK 100
Cl COVER PAGE