HomeMy WebLinkAbout19-21164 CITY OF ZEPHYRHILLS • 5335-8th Street (813)780-0020 21164 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:21164 Issued: 5/01/2019 Address: 38620 PIEDMONT AVE Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 21,800.00 Total Fees: 225.00 Subdivision: ALPHA VILLAGE Amount Paid: 225.00 Date Paid: 5/01/2019 Parcel Number: 35-25-21-0050-0000-0850 CONTRACTOR INFORMATION OWNER INFORMATION Name: PALMETTO CLEAN TECHNOLOGY INC Name: HAYNES JAMES & DIANE Addr: 1505 KING STREET LLC DBA Address: 38620 PIEDMONT AVE NORTH CHARLESTON SC 29405 ZEPHYRHILLS, FL. 33540-1431 Phone: (707)716-0084 Lic: Phone: (813)395-8454 Work Desc: ROOF MOUNT SOLAR SYSTEM APPLICATION FEES ELECTRICAL FEE 225.00 INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE J PRE-METER p0 �O FINAL L �UV 1 -5 REINSPECrION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. CONTRA T PER OFFI PERMI IRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 702-716L-0084 owners Name JAMES HAYNES Owner Phone Number (813)788-7777 Owners Address 1 38620 PIEDMONT AVENUE ZEPHYRHILLS,FL 33540 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 38620 PIEDMONT AVENUE ZEPHYRHILLS, FL 33540" LOT# SUBDIVISION ALPHA VILLAGE ESTATES I PARCEL ID# 35-25-21-0050-00000-0850 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK Roof Mounted solar system. BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION x=ELECTRICAL $. I J�OC) AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ( =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES NO I - —— i :-i BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address A License# ELECTRICIANT v v L I�COMPANY Palmetto SIGNATURE REGISTERED Y/ N FEE CURREK Y/N Address 150 King St Ext,Ste 114 North Charleston,SC 29405 License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREK Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREK Y/N Address License# 1111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Storrnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ` NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,600.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone'V'unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INT ND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUlk NaTICE bF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGEN* � TRACTOR Subscribed and sw to(or affirm d)b fore me this Sub d sw n to or affir )bef°�e me this by .by y . $3 L 1 is/ a pgrsonally known to me or hasihave produced is/are p rsonall known to me or has/have produced (� as identification. I as identification. Notary Public a- )A_2 Notary Public Commission No. Commission No. am ti e d r sta/hp€ Nam of Notary typed printed or stamped r rtyG Notary Public S to of Florida r Erica Marie McCurdy a My Commission GG 112270 Expires O6/O6/2021 =o1�t Pu�� Notary Public State of Florida Erica Matte McCurdy y My Commission GG 112270 Expires 06/0612021 _ DgcuSign Emvelope ID:0188E296-0506-4052-A70B-570F20BB6501 Envirosolar Purchase Summary Contractor Name: EnviroSolar Customer Names: James Haynes Purchase Date: 2/5/2019 1 2:47:39 PM CST Itemized List of Purchased Products and Services: 1. 4.13 kw system 2. 0 solar attic fans 3. 1 Energy Management System 4. 50 LEDs 5. 6. 7. 8. 9. Total Purchase Price: 21800 THIS PURCHASE SUMMARY DOES NOT CREATE A BINDING AGREEMENT BUT SOLELY IS A SUMMARY OF THE BINDING AGREEMENT WHOLY CONTAINED IN THAT CERTAIN SALES CONTRACT OF EVEN DATE BY AND BETWEEN CUSTOMER AND CONTRACTOR. DocuSigned by: Customer(s): ,;;(s (ka Vxs 803OA934771MB2... Contractor: EnviroSolar_ By: Ffocuftned by: r AUV. i M W uur DBO i 4AC... Name: Trevor Monci bai s YOU, THE BUYER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAY AFTER THE DATE OF THIS TRANSACTION. SEE THE ATTACHED NOTICE OF CANCELLATION FORM FOR AN EXPLANATION OF THIS RIGHT. Enclosure:Three Day Cancellation Notice DATE: March 15,2019 RE: 38620 Piedmont Avenue, Zephyrhills, Florida 33540 To Whom It May Concern, As per your request, we have conducted a structural assessment of the building at the above address that included a site inspection on March 8,2019.This inspection included an examination of the roof structure and condition as well as any structural drawings that were available. PV solar panels are proposed to be installed on roof areas as shown in the submitted plans.The panels are clamped to rails which are attached to the roof with a lagged mounting system, and installed per manufacturer's specifications and recommendations. It was found that the roof structure as noted on S3 satisfactorily meets the applicable standards included in the FBC 2017 61h Edition,2015 IBC/IRC and 2018 IEBC. Design Criteria: Wind speed = 137 MPH Ground snow load =0 psf Roof dead load =9 psf Solar system dead load =3 psf The roof was determined to have asphalt shingles atop half-inch plywood sheathing. Overall the roof area is structurally adequate to support the additional load of the solar panels and,their framework. ,p��uuurn4rr Acknowledged by: O`ON "A215 by signed No.81142 s Chris by Chris H Kim E 'Date: = 2019.03.15 Q •. EH K•m- P '15.46:32-0400 Chris Kim, P.E. � AL r r City of Zephyrhills BUILDING PLAN REVIEW COMMENTS � E Contractor/Homeowner:Date Received: Yh Site: �0,6 ye, ' Permit Type: p O V jr)��� Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet hall be keXpaitli the permit and/or plans. Kalvin itzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2099056764.OR BK 9884..PG,3807 Page 1 of 1 , a 04/04/2619.12:10 PM Rapt::2043010 Rec: 10.00 DS:0.00 IT:0'.00 Paufei S. O'NeiC Ph.D.,Pasco County Cf&k&Cbntptroller Perrirll No. Parcel ID Na.3S•25.214050.000DO-0860 NOTICE OF COMMENCEMENT FLORIDA . Sbte of Count'of PASCO. THE UNDERSIGNED her paves notce That improvement wdD De mode to CQrfAtt teal property,end ki accordance vrtth Chi p[er 713,Florida Statutes, the foIIovdnp thiortnedon la provded In this Notice of Commencement 1. Description of Prop art-..Parcel ldentifiagon No.3f2S210054C090o-ea50. Se tat Address:-38620 PIEDMONT AVENUE ZEPHYRHILLS,FL 33540 2. General Description of improve.ment INSTALLATION OF ROOF MOUNTED PHOTO VOLTAIC SYSTEM' 3, 'Owner Intoenatlyn or Lessee Information it the Lessee eenbaded for the linprovemont JAMES&DIANE HAYNES >aaw¢ao.+aona. Name ZEPHYRHILLS FL' . AdQ ass City State Interest In Property:.OWNER" Name of Fee Slmple Titleholder fit-different from Owner listed strove):. Address Gry - State 4: Contractor: Name rrasrcardox� North Charleston'_ SC, 'Address City. State:. Contrecto/sTclepboneNo'.t 8437201844 • 8. 6woty: , Name , ` Address city. State' = Amount of Bored;-S Telephone No.:. 8. Lender Name Address City_ State Comdata Telephone No.: 7. PorsoM within the Stela of Florida designated by the owner upon whom notices or other dowmanls may ba sorvod as proV.ded by Section 713.13(1)(e)(7),Florida Statutes: Name . Address . . City State `� ~ UIt' Telephone Number of Designated Pareon t4 W-lL ' U U � � U— —1 8. In addition to himge8,the ovmer designates of_ O � to rece)va a copy of the Uenor i Notice as provided In Section 71 rid 3.13(1)(b),Floa Statraes. Q U '<..N O :Tele hone NumW of Person or P ErSy Deslpnated by Owner_ L .p F E w U.)a W. 8. Expiration date ofNotice of Commencement(the expiration dab may not ba before.the domplotan of constriction and final payment io.tho W jE eonlra ior,[cot v.0 be one year Irarn the dale of recordiI.ng uNesa i ddfammi Este is specified): O 5, V WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT.' lJ1 O�'•— ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713.PART 1 SECTION 713.13 FLORIDA,STATUTES..AND CAN ' }:W'LL RESULT.IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROARTY. .A NOW69 OF COMMENCEMERF MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION,IF YOU INTEND TO OBTAIN FINANCING,CONSULT 0 1- d a O' WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.' V S 00 Cr W'. Ungar penally of per)ury;I declare I mt 1 have read thi foregoing notice of commenearnonl and that the fads stated therein era trite 10 the best of my knowledge and belleL 0 m V STATE OF FLORIDA LLI �Z O J COUNTY OF PASCO �� lei W Signs fownerar ssee,or erL essedsAuthorized W'O O 0_ 0 odl dl or/PaMsr/Managor U () �. lZ bw+.i dy. . .0 o 0 SignatorysTmerofka LLI fn¢Lif cw� • W _j UJ fieum foregoing Instrument was ada W towfedged before me s .!' day of 20 ft by. 0'$4FC cn=_.-)I of -'0"3 . of only,a.g.,outer.tru tee.adbmay in tad)for s 1 Z _� ( _ IM pa baheM c o m Instrument eras executed). r ~ O v � Perso4!ly Known[3 9E Produced ldentificati-on Lzl' Notary Signature G��G • 'a Type of ldontMcation Produced- L V4 Name(Primp o ar-•zy_i4•uts•ubtit:Stile tit Fbrid 0 �%' .-S' ,s ':�� � rea11Y P.. -E MaAa/AeCutoY oo t' ylCot11m1ubn t30172270 .� r •, C Dy Ina 0810ed2DZ1 xf`/y. N9dala/bWnollccmmmenearrtenL,pc053040 I Power Optimizer ForNorthAmerica P320/P340/P37/P400/P405/P5 _.. Alwk�etpixxrlyrt �, *} U #7 A k w.w�Arae saw us Ps nac Ar uus x al a6 Iwt 1►44 +, 1 w � � 14iiw/�xni�lrx At 11 l�Iltirs111f aisalaz$I t2$i slat 22$ ilix>Zt CMM�M�O�l4WIII2$ t sa i22 afsxs,Iu Sxs,$:Ln SiclrLai Sxs$ 2a rwti SLIM 722117 3*11.2 1N$I2J tit wM aarriwirtcra 3 I Utti stit t1sl1ts7 rti ar PV power optimization at the module-trod • • I Vuft t didto wort with SolsEdpe ! F ban wRh a side bolt Irwaftrs It _Rh nnodde- Up bo 2914 mare eneer iced I Supecbr 1 td s1 G re crtsior arc tavlt w« ar+ttcrar► n ss P and PbQtwj0Rair Rapid Mibrs aR types of nm*ie ni loses, w.r .wr..assrro s or+cc- smr aaxs w *ate nman�aacrrinp tolerance do p[rtiei I IW0dule-lard voltage 3hmb$own tar i aRer > s I fiedble syi deslyn icx m drown space •Ar t �rrsw+�ir�r�rsrrp7S+SarrAw +M�I+iN►1n1�Fi�rrtrrwlNrrwr#111i1+n+R sole " z PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE A5-OPTIMIZER SPECIFICATIONS PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 \`��� WWW.PALMETTO.COM CLIENT:J. HAYES REV:- solar • • • Single Phase Inverter solar ' e with HD-Wave Technology for North America SE3000H-US/SE3800H-US I SE5000H-US/ Single Phase Inverter SE6000H-US/SE7600H-uS/SE10000H-US/SE11400H-US with HD-Wave Technology • for North America SM 6°e %00 = 0 1140 VA SE3OOOH•US/SE OOH-US/SE5000H•US/ i .ACpowshra phA 3Qoo �: "°"' Sw s000�24ov 7sao 10°°°.,. 11400 VA kahrphht i f .. f vx SE61 H-US/SE760OH-US/SE1OOo0H-US/SE1140OH-US .... NomrFAhnc ' AC Output ftItaie Mn-Nor;:Max, / / .r ✓ ✓ / v: ACFrsquency(Nominail ... ....... 583-6060.5 _•., i!z ... lulii�n urn ccl thuot5 Output Current 16 2°...... ......:........ A CY ......:.............................. ............. . ..... ..... _...,....,.,.. .., .,,....... .....47..S ..,.. . CohtlrNhatr3Outp t 12S Y6 21 .. 3242 47S A•{ fF0IYltresi!oid... _........ ................ .. ...... .. A.... 1j • t,N l'Moil andin4 Protectlon. lBes MiodnwtrhW:Powar 240Y 4650 X00 T750 • 9104 11800 15500 37550 4V WlnhimunsOtpawer•Zdfft 5100..... ............. 7710 .... .............,. ,... ......... . .......,. s .. lies. Maximum.h ............ .......................... . ... ' .100 .. .......PmmaIhtVolte .3oi .. • Mndrthurn Mhut Chure�t 208V „ - 9 13S - .. .. i Ma�dmun Currerht 2A0Y ..BS.. ..RU.S. .13.5.. 16.5 2Q.. 27 .:...... ............... .... . .. . ... .....:.. . ..... ..... :... .... .. , ,, . y.4ne���a .T!NCMM! ..... ............... ................ ...r .... ...........,.. .............. ,.,...x w. atlpoeeh ........ .. ... jj ..... ..... ....a .:...x. '• ......w.,,,. .. ..,a.,............,...... wa - Mikhrll11111(IY'lfTer C•".-.`. . ........ ..... ......3 99.3 .......... ......,........,..,,............ % .., • c. a.............. ........,....... ...a . .... ... . ,...a..,,.,..... .......;..,,,.>,. .,....,....... .a for Consu <2 3 w SupcortedGorernu ionlMerfaces.. 85485 Ethernet. ee(o*Iona).Cellular{oplbrai�...,....... ReMeehyp. ....R ta..ANSI12.2) . . ., ,..... h n Rapid Shutdown-N 2014 and 2017 ........... .... ............ .. . Autmudc RWW Shutdosrtn upon AC Grid Obcomed Sit . ...... ................. ......x.w...a...UL1741.uu7ex SA,ut 1699ew,C5A C22 Zr cans an AFcl accord to TI L M- 7 cdcomer{onsearas............... ............, .. .x.a... EYsa,au+e1iieil..,..,,. ... . ......a.. .............. ........ Ehrhitsi4ns FCC Part 15 Class ac Output or! sme fawn atp ...... ..........3a"mMdmaera/14.6 AW ..... ............... ,.Y4•rw, wn,/Y-4 Aws Drdu.tSinejiofark 3�4'rthkhiarnam/i3stdrags 3<4" +m/13 strk+gs J 14..AwG ........ ....I........... .... ... ...... ... ... ........ ........... Wmensions with Safety Switch(NxWxD) 17.7x 14.6x6.8/450 x 37Dx 174 21.3x14.6:7.3/540x370 in/mm ...... . Wenightwhh5afetySwch 22/10 I 251!114 I 26,2/11.9 ....,... 98(176 /kd 25 d8A ...Noise .., kN6 ............. ................. ......IlstwaI ortyectlaxh ...... Natural con ectlan ..... -4a'copaon�".............'..; .... .. ,....... .Fc., Prot on.lgtlni... ... ... ..I+EMA t{inwertw wNh 5atetY riDch� uhwaar..de.ut ptwa------.a«E4rNOW w�e...rhre:Iw www.solaredge.us PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE A4-INVERTER SPECIFICATIONS PHONE: +1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 WWW.PALMETTO.COM CLIENT:J.HAYES REV:- IIIIIIIIIIIUIIl I_ ♦ �� • i � Ali • # r 1 I iii 1T w ,_ 6 i.1I4i1.I IJ1 ■ W !R iii-.■L:SiJi 1 ;_,h'_1I' i tv �.�®iii `: .tip► ;rtt, ►�I it :.'l;i I ( * :... 8NAPNRACK,STANDARD RAL DRyan SflaINvodç - REVISION: tifl S1UU 232-01067,232-01068,232-01069,232-01070, J .� 232-02112,232-02113 Ir _______ B JJ7Jr 44 ALL DIMU6IONS IN V MA1 1ALS: 6400 SERIES ALUMINUM OPTIONS: DESIGN L (LES): WA /I ULTIMATE LOAD(M: N/A MILL FINISH TORQI SP JLTION: N/A LOFT 12?!16?LE CERTIFICATION: UL 2703,FU.E 059313 BOXES OF 216 WEIGHT(1.68): 7.65-10.16 BUNDLES OF 112 PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE A2-RACKING SPECIFICATIONS PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19 WWW.PALMETTO.COM CLIENT:J. HAYES REV:- { Test talons NOCT Module Per 227 24 `pmt ttwer V g t.. Alat�tum curatt A 769 OpedrtvItjge V 369: # Short draua currant A 736 MoA�e s *13 V edesfuse r A Tolerance wp 01+5 r ► moa,iatror � a w •wurris+�ss 1 lsc %/K T CoafldettVoc %lK Te aetecoeflidentPtnax WK 100%MAXIMUM POWER DENSITYl t:T r 45 Silfa&s SEAM 300 ultra-high-efficiency p Ic modules are optimized for both Residential and Commercial projects where maximum power density is preferred• Module t • It Qmertsions(H x L x D;t 1 mm 1650*990x 100%NORTH AMERICAN Maximum surfaEeioad tainelsn M'' Nh QQUAUTY MATTERS " tF rtxrt x s km/h Silfab's fuily automated manufacturing facility teas ._._ ensures precision engineering is applied at 3.2 rhm hipt a a stnibtattce� atttir ve costirt every stage.supelor reliability and performance -based combine to produce one of the highest #rra me, quality modules with the lowest defect rate 3 dlod iiJ12M tP67JiF in the Industry, t':ahies and cars#see tnA Lion cr,a j NORTH AMERICAN Module productttiarraoty CUSTOMIZED SERVICE jl Silfab`s 1tl0%NorthA nerlcan based teamLkear power perfc.mance> ≥90%endorI2yea leverages just-one manufacturing to deliver service on-time delivery and :a of25•year tlexittle prt�at solutktns. UtC ORDC1.703,Ut 1743.IEC 6121$,lE 61730,IEC61701,CEC listed Product1 UL Fire Retir2f Ion recpj LWanilng Read Uie lnstallaUon and User Manual before _____________ hen Mistat tg and modules Tlfrd-partygenerated panfNes from 'm PVEvolttlon tabs available g far do en lcad oavaa *Pa$et Cwutt 26 Contains'Gaunt 936 a �lwwsar 4J ) 56fabSolar Inc. ..�...�... 24CCow wparkDdveE.'s+fi aug& " 1j 0rft oC.anaaatsT2 r Tel+1905.256.2501'Fax+1905-696-0267 -wNrsEab.ca PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR:EE Al -PANEL SPECIFICATIONS PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 WWW.PALMETTO.COM CLIENT:J. HAYES REV:- I 1 FORMAT 1.WHITE LETTERING ON A RED BACKGROUND • 2.MINIMUM 3/8 INCHES LETTER HEIGHT 3.ALL LETTERS SHALL BE CAPITALIZED ELECTRIC SHOCK HAZARD 4.ARIAL OR SIMILAR FONT(NON-BOLD) TERMINALS ON BOTH THE LINE AND LOAD SIDE I I I [NEC 690.13(B)]ALL AC DISCONNECT SHALL BE MATERIAL MAY BY ENERGIZED IN THE OPEN POSITION LABELED REFLECTIVE,WEATHER RESISTANT MATERIAL TURN RAPID SHUTDOWN SUITABLE FOR THE ENVIRONMENT(USE UL-969 SWITCH TO THE"OFF" AS STANDARD FOR WEATHER RATING). [NEC 690.131 PLACE THIS LABEL ON ALL POSITION,TO SHUTDOWN I • • • • A DURABLE ADHESIVE MATERIALS DISCONNECTING MEANS WHERE CONDUCTORS OUTSIDE ENERGIZED IN AN OPEN POSITION THE ARRAY. CONDUCTORS WITHIN ARRAY REMAIN ENERGIZED IN SUNLIGHT [NEC 690.13(B)]ALL DC DISCONNECT SHALL BE LABELED PHOTOVOLTAIC • 46o vDc J POWER SOURCE [NEC 690.56(C)]PLACE AT MAIN SERVICE PANEL 15 AMPS [NEC 690.31 (G)3&4]PLACE ON ALL JUNCTION PLACE THIS LABEL WITHIN MAIN SERVICE DISCONNECT(OR ON OUTSIDE 15 AMPS BOXES.EXPOSED RACEWAYS EVERY 10' DISCONNECT OF OPERABLE WITH COVER CLOSED) [NEC 690.53]PLACE AT EACH DC EQUIPMENT DISCONNECTING MEANS j • ui ♦ II1mnh', [NEC 690.54]PLACE LABEL AT"INTERACTIVE +�* � '." rrrs * POINT OF INTERCONNECTION"(AT MAIN �` Q N $1142 ". SERVICE PANEL AND SUBPANEL IF APPLICABLE) t 9 CONTAINS MULTIPLE j': ST £ POWER SOURCES '% ip'`=•' [NEC 705.12(D)3]PLACE LABEL ON ALL QL " { EQUIPMENT CONTAINING OVERCURRENT D s !! DEVICES IN CIRCUITS SUPPLYING POWER [NEC 690.56(C)]PLACE NO MORE THAN 3.3FT TO A BUSBAR OR CONDUCTORS SUPPLIED FROM SWITCH FROM MULTIPLE SOURCES NOTES: 1) ALL LABELING USED OUTDOORS MUST BE ENGRAVED METAL, UV STABILIZED ENGRAVED PLASTIC OR OF A MATERIAL SUFFICIENTLY DURABLE TO WITHSTAND THE ENVIRONMENT INVOLVED. VALUES HAND WRITTEN OR IN WRITTEN IN MARKER ARE NOT ACCEPTABLE PER NEC 2017. 2) LABELS USED INDOORS MAY BE MADE OF DURABLE VINYL OR PAPER 3) DO NOT COVER ANY EXISTING MANUFACTURER APPLIED LABELS WITH INSTALLA11ON SPECIFIC LABELS 4) LABEL COLORS CHOSEN PER NFPA 70 2017 DIRECTION THAT ANSI Z535-2O11 BE USED 5) REQUIREMENTS COMPLY WITH NEC 2017 6) ADDITIONALLY, IT IS HIGHLY RECOMMENDED THAT THE INSTALLER ATTACH A LABEL WITH THE COMPANY NAME AND CONTACT INFORMATION AT THE INVERTER 7) ALL WARNING SIGNS OR LABELS SHALL COMPLY WITH NEC 110.21(6) { PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE E3-WARNING LABELS PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 WWW.PALMETTO.COM CLIENT:J. HAYES REV:- SYSTEM SUMMARY STRING 1 STRING 2 STRING 3 POWER OPTIMIZER MAXOUTPUT CURRENT 15A N/A N/A SOLAREDGE MAXSTRING SIZE OPTIMIZERS IN SERIES 14 N/A N/A MODEL SE38WH-US ARRAY STC POWER 4200W MAXSTRING POWER 5700W MAX AC CURRENT 16A PMAX PANEL 300W NOMINAL AC POWER 3800W MAXSTRING SIZE 19 MODULES QUANTITY MAKE AND MODEL PMAX ISC IMP VOC VMP TEMP COEFF OF VOC FUSE RATING 14 SILFAB SLA-M 300W 30OW 9.71A 9.16A 39.85V 32.80V -0.30%/°C 15A POWER OPTIMIZERS QUANTITY MAKE AND MODEL RATED INPUT POWER MAX OUTP UT CURRENT MAX INPUT ISC MAX DC VOLTAGE WEIGHTED EFFICIENCY 14 SOLAREDGE P320 320W 15A 11A 48V 988% INVERTERS QUANTITY MAKE AND MODEL AC VOLTAGE MAX OCPD RATING RATED POWER MAX OUTPUT CURREI�I'F MAX INPUT CURRENT MAX INPUT VOLTAGE CEC WEIGHTED EFFICIENCY 1 SOLAREDGE SETH-US 240V 50A 3800W 16A 10,5A 480V 99% OCPDS OCPD SOLAR BREAKER CALCULATION QUANTITY RATED CURRENT MAX VOLTAGE MAX OUTPUT CURRENT NEC MULTIPLIER MIN OCPD SOLAR BREAKER 1 20A 240V 16A 125% 20A ID CONDUCTOR CONDUIT #OF CCCs IN CONDUIT* OCPD EGG CONT. CURRENT MAX CURRENT 1 10 AWG PV WIRE, COPPER FREE AIR N/A N/A 6 AWG BARE, COPPER 15A(PER STRING) N/A 2 10 AWG THWN-2, COPPER 0.75" DIA. EMT 2 N/A 10 AWG THWN-2, COPPER 15A(PER STRING) N/A 3-4 10 AWG THWN-2, COPPER 0.75" DIA. EMT 2 20A 10 AWG T WN-2, COPPER 16A 20A ID CONDUCTOR BASE. AMP FILL FACTOR DERATED AMP. TEMP. FACTOR** TEMP. DERATING ' +�r 2 10 AWG THWN-2, COPPER 35A 1.00 35A (1.96 33 6A . .«,...* . 3-4 10 AWG THWN-2,COPPER 35A 1.00 35A 0.96 33.6A ��El1►s •. . *CCCs REFERS TO CURRENT CARRYING CONDUCTORS a � "TEMPERATURE FACTOR IS BASED ON 2% DRY BULB HIGH WITH NO TEMPERATURE ADDER THEREFORE RACEWAYS MUST BE AT LEAST 7/8"ABOVE ROOF PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR. EE E2-ELECTRICAL CALCULATIONS PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 11� WWW.PALMETTO.COM CLIENT:J. HAYES REV:- BI-DIRECTIONAL UTILITY METER •� ,•'• 4 TO BE INSTALLED BY DUKE ENERGY No,81142 .�• �, E �g L7 L2 i sir �'•,• ,t +�* MAIN SERVICE PANEL �!i# •�•••+,r+ 240/120 V 10,3W,150A MAIN 1S0A/2P (E) 0 LD (E) (E) ® (E) VISILE LOCKABLE B MAIN (E) ® (E) SERVICE DISCONNECT (E) (E)jE INVERTER 1 240/120 V 10,3W SOLAR EDGE SE3800H-US 3 20AF/30AS 4 (E) ui (E) WITH DC DISCONNECT,NEMA3R NEMA3R JUNCTION BOX (E) ® (E) 1 STRING OF 14 MODULES EACH NEMA3R CONNECTED TO P320 OPTIMIZERS 1 240V (E) ® ® (E)jE Lç (N)2oArzP (E) DC+ • DC+ O 0� DC ono SOLAR BREAKER LOCATED ® AT THE FURTHEST END OF EGC BUS BAR FROM THE MAIN G G BREAKER OR FEEDER UNIT EGC G GEC PHOTOVOLTAIC SYSTEM GROUND EQUIPPED WITH RAPID ROD SHUTDOWN,INTEGRATED DC DISCONNECT&ARC FAULT PROTECTION INVERTER SPECS MODULE SPECS ASHRAE AMBIENT AIR SPECS OP11MI2ER SPECS MAKE: SOLAREDGE TECHNOLOGIES LTD. MODULE MAKE: SILFAB SLA-M 300W 2% DRY BULB TEMP: 92.8°F MAKE: SOLAREDGE TECHNOLOGIES LTD. MODEL: SE3800H-US MODULE QUANTITY: 14 MODEL: P320 MODULE POWER. 300W DISTANCE ABOVE ROOF (> 7/8"): 92,8°F INPUT INPUT OUTPUT MAX INPUT VOLTAGE: 480V VOC: 39.85V VMP: 32.80V EXTREME MINIMUM: 12.7°F MAX VOLTAGE 48V 60V MAX INPUT CURRENT 10.5A ISC: 9.71A IMP: 9.16A MAX CURRENT 13.75A 15A MAX DC POWER: 5900W WIRE SCHEDULE ID CONDUCTOR NEUTRAL EGC CONDUIT KIT OUTPUT 1 (2)#10 AWG PV WIRE, COPPER N/A (1)#6 AWG, BARE, COPPER EGC N/A FREE AIR NOMINAL AC POWER OUTPUT: 3800W 2 (2)#10 AWG THWN-2, COPPER N/A (1)#10 AWG, THWN-2, COPPER EGC 0.75" DIA. EMT NOMINAL AC OUTPUT VOLTAGE: 240V 3-4 (2)#10 AWG THWN-2, COPPER (1)#10 AWG THWN-2, COPPER (1)#10 AWG, THWN-2, COPPER EGC 0.75" DIA. EMT MAX OUTPUT CURRENT: 16A PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE El -LINE DIAGRAM PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 WWW.PALMETTO.COM CLIENT:J. HAYES REV:- Materials included-L Foot Fk tdng Kit .(0 LF.a5 •rn••. ad*000."'._L •mvw- n w@"a'!wg • LAG SCREWS SHALL Other Materials Required tl n eov'rwor.. BE S.S. 5/16 X 4 W/ 2.5" MIN EMBED IN r RAFTERS/TRUSS TOP CHORDS TOP CHORD °'~ "� TOP CHORD 2x4 @ 24" O/C in WEBBING 2x4 @ 24" O/C BOTTOM CHORD 2' f 12'-4" ROOF 1 uIni ,,,,, f' .<$CEN .. 3 No.81142 * - MAX. 48" `*. ST E . TOP CHORD SPACING: 24" MAXIMUM MOUNT SPACING: 48" MOUNT PATTERN: STAGGERED rSCALE-.NTS PANEL TYPE: SILFAB SLA-M 300W NOTES: PANEL SIZE: 65.0"x 39.0" - SCALE AS SHOWN RACKING TYPE: SNAPNRACK 100 - ALL DIMENSIONS IN FEET UNLESS MOUNT TYPE: SNAPNRACK FLASHED L FOOT OTHERWISE STATED SOLAR SYSTEM DEAD LOAD: 3.0 PSF PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE S3-STRUCTURAL DETAIL PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19 mo WWW.PALMETTO.COM CLIENT:J. HAYES REV:- S I . f - -- 48'-7" - CABLE (MOVABLE); :; u i % ��//// / / // ////i / iii/////// //� ///ii //ii X/ i////ii it//!/ir/ /i/ii/� �t Iii//ii%i/viii�'//iiri/✓��fii 1 ._ �i//��iii/��ii!/''viii�/////��iiii� i� VET BOX ///�/✓////i/iii iii PVC VENT 10"TYP 4'-64' / / uuu LEGEND ROOF 1 a .•w�GE�sF��: , , TOP CHORD PITCH 18.5° Na81142 AZM 182 METER STATE .'• 3 FIRE ACCESS ¶ 4P' / PATH DECIDUOUS TREE DECIDUOUS TREE A�- FIRE TREETOP 29' 1 VENTILATION TREETOP 26' CANOPY 15' CANOPY 15' I SCALE: 18 I ROOF PITCH: 18.5° SLOPED SHINGLE ROOF PANEL TYPE: SILFAB SLA-M 300W NOTES: AZIMUTHS: 182 DEGREES PANEL SIZE: 65.0"X 39.0" - SOLAR PANEL LAYOUT SUBJECT TO CHANGE ACCORDING TO III RACKING TYPE: SNAPNRACK 100 NUMBER OF PANELS: 14 EXISTING CONDITIONS MOUNT TYPE: SNAPNRACK FLASHED L FOOT SYSTEM SIZE:4.20 kW - SCALE AS SHOWN GROUND TO EAVES DISTANCE: 8'-3" - ALL DIMENSIONS IN FEET UNLESS OTHERWISE STATED PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE S2-PANEL LAYOUT PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS, FL DATE: 14/MAR/19 t\ WWW.PALMETTO.COM CLIENT:J.HAYES REV:- I PIEDMONT AVENUE f___ 73'-8<" __ 38620 PIEDMONT AVE ✓ 48'-8z" ,r DWELLING N. WALL INVERTER w/WARNING LABEL AC DISCONNECT w/WARNING LABEL SERVICE POINT & UTILITY METERING N DISTRIBUTION PANEL w/WARNING LABEL of Vii„ O) Lii z •�f•rrG rr�f f {� f • � • Digitally signed 38620 PIEDMONT AVE C i i Chris by Chris H Kim DWELLING ate: H K' x.15 15:45:47-04'00' I SCALE: 1" 18' NOTES: SAFETY PLAN: NEAREST URGENT CARE FACILITY j - SCALE AS SHOWN - INSTALLERS SHALL DRAW IN DESIGNATED SAFETY AREA AROUND HOME NAME: - ALL DIMENSIONS IN FEET UNLESS - INSTALLERS SHALL UPDATE NAME,ADDRESS,AND PHONE NUMBER OF ADDRESS: OTHERWISE STATED NEAREST URGENT CARE FACILITY RELATIVE TO THE SITE BEFORE STARTING PHONE NUMBER: WORK PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE S1 -SITE PLAN PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19 j ," WWW.PALMETTO.COM CLIENT:J.HAYES REV:- GENERAL NOTES: III ALL MATERIALS, EQUIPMENT, INSTALLATION AND WORK SHALL COMPLY WITH THE FOLLOWING APPLICABLE CODES: IBC 2015, IRC 2015, IFC 2015, NEC 2017 • WHEN A BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION,THE BREAKER SHALL BE • PV SYSTEMS SHALL BE PERMITTED TO SUPPLY A BUILDING OR OTHER STRUCTURE IN ADDITION TO ANY INSTALLED AT THE OPPOSITE END OF THE BUS BAR OF THE MAIN BREAKER. OTHER ELECTRICAL SUPPLY SYSTEM(S)[NEC 690.4(A)1 • TO REDUCE FIRE HAZARDS, DC PV SYSTEMS WILL BE EQUIPPED WITH A GROUND FAULT PROTECTION • THE INSTALLATION OF EQUIPMENT AND ALL ASSOCIATED WIRING AND INTERCONNECTION SHALL BE SYSTEM IN ACCORDANCE WITH NEC 690.41(B) PERFORMED ONLY BY QUALIFIED PERSONS[NEC 690.4(C)] • WHERE GROUND-FAULT PROTECTION IS USED,THE OUTPUT OF AN INTERACTIVE SYSTEM SHALL BE • EXISTING PLUMBING VENTS, SKYLIGHTS, EXHAUST OUTLETS,VENTILATIONS INTAKE AIR OPENINGS CONNECTED TO THE SUPPLY SIDE OF THE GROUND FAULT PROTECTION[NEC 705.32] SHALL NOT BE COVERED BY THE SOLAR PHOTOVOLTAIC SYSTEM. • ALL PLAQUES AND SIGNAGE REQUIRED BY THE LATEST EDITION OF NATIONAL ELECTRICAL CODE. LABEL • INVERTERS, MOTOR GENERATORS, PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS,AC SHALL BE METALLIC OR PLASTIC, ENGRAVED OR MACHINE PRINTED IN A CONTRASTING COLOR TO THE PHOTOVOLTAIC MODULES, SOURCE-CIRCUIT COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR PLAQUE. PLAQUE SHALL BE UV RESISTANT IF EXPOSED TO SUNLIGHT. USE IN PV SYSTEMS SHALL BE LISTED OR FIELD LABELED FOR THE PV APPLICATION [NEC 690.4(B)] • ALL THE NEC REQUIRED WARNING SIGNS, MARKINGS,AND LABELS SHALL BE POSTED ON EQUIPMENT • ALL OUTDOOR EQUIPMENT SHALL BE NEMA 3R RATED(OR BETTER), INCLUDING ALL ROOF MOUNTED AND DISCONNECTS PRIOR TO ANY INSPECTIONS TO BE PERFORMED BY THE BUILDING DEPARTMENT. TRANSITION BOXES AND SWITCHES. • CONNECTORS SHALL BE OF LATCHING OR LOCKING TYPE. CONNECTORS THAT ARE READILY • ALL EQUIPMENT SHALL BE PROPERLY GROUNDED AND BONDED IN ACCORDANCE WITH NEC ARTICLE 250. ACCESSIBLE AND OPERATING AT OVER 30 VOLTS SHALL REQUIRE TOOL TO OPEN AND MARKED"DO NOT • SYSTEM GROUNDING SHALL BE IN ACCORDANCE WITH NEC 690.41 DISCONNECT UNDER LOAD"OR"NOT FOR CURRENT INTERRUPTING". [NEC 690.33(C)&(E)(2)] • FOR PV MODULES, EQUIPMENT GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL COMPLY WITH • FLEXIBLE, FINE-STRANDED CABLES SHALL BE TERMINATED ONLY WITH TERMINALS, LUGS, DEVICES, OR NEC 250.120(C)[NEC 690.46] CONNECTORS IN ACCORDANCE WITH NEC 110.14 • ALL PV SYSTEM DC CIRCUIT AND INVERTER OUTPUT CONDUCTORS AND EQUIPMENT SHALL BE • WORK CLEARANCES AROUND ELECTRICAL EQUIPMENT WILL BE MAINTAINED PER NEC 110.26(A)(1), PROTECTED AGAINST OVERCURRENT UNLESS STATED OTHERWISE IN NEC 690.9(A) 110.26(A)(2)AND 110.26(A)(3). • OVERCURRENT DEVICES USED IN PV SYSTEM DC CIRCUITS SHALL BE LISTED FOR USE IN PV SYSTEMS • ALL EXTERIOR CONDUITS, FITTINGS AND BOXES SHALL BE RAIN-TIGHT AND APPROVED FOR USE IN WET LOCATIONS PER NEC 314.15. [NEC 690.9(B)] • PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION IN • ROOFTOP MOUNTED PHOTOVOLTAIC PANELS AND MODULES SHALL BE TESTED, LISTED&IDENTIFIED IN ACCORDANCE WITH UL1703 ACCORDANCE WITH NEC 690.12 • EACH MODULE TO BE GROUNDED USING THE SUPPLIED CONNECTION POINT PER MANUFACTURER'S • DISCONNECTING MEANS SHALL BE LOCATED IN A VISIBLE, READILY ACCESSIBLE LOCATION WITHIN THE REQUIREMENTS.ALL SOLAR MODULES, EQUIPMENT,AND METALLIC COMPONENTS ARE TO BE BONDED. PV SYSTEM EQUIPMENT OR A MAXIMUM OF 10 FEET AWAY FROM THE SYSTEM [NEC 690.13(Aj] IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED OR IS ONLY METALLIC WATER • ALL WIRING METHODS SHALL BE IN ACCORDANCE WITH NEC 690.31 PIPING, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING • CONNECTORS SHALL REQUIRE A TOOL TO OPEN AND BE MARKED"DO NOT DISCONNECT UNDER LOAD" ELECTRODE. OR"NOT FOR CURRENT INTERRUPTING". [NEC 690.33(E)] • DC CONDUCTORS SHALL BE RUN IN EMT AND SHALL BE LABELED, "CAUTION DC CIRCUIT'OR EQUIV. • ALL GROUNDED CONDUCTOR SHALL BE PROPERLY COLOR IDENTIFIED AS WHITE. [NEC 200.6] EVERY 5 FT. • CONFIRM LINE SIDE VOLTAGE AT ELECTRIC UTILITY SERVICE PRIOR TO CONNECTING INVERTER.VERIFY • PV SYSTEM CONNECTED ON THE LOAD SIDE OF THE SERVICE DISCONNECTING MEANS OF THE OTHER SERVICE VOLTAGE IS WITHIN INVERTER VOLTAGE OPERATIONAL RANGE. SOURCE(S)AT ANY DISTRIBUTION EQUIPMENT ON THE PREMISES SHALL MEET THE FOLLOWING[NEC 705.12(B)]: • SERVING UTILITY TO BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM. 1) EACH SOURCE CONNECTION SHALL BE MADE AT A DEDICATED CIRCUIT BREAKER OR FUSIBLE • ELECTRICAL CONTRACTOR TO PROVIDE CONDUIT EXPANSION JOINTS AND ANCHOR CONDUIT RUNS AS DISCONNECTING MEANS. [NEC 705.12(B)(1)] REQUIRED PER NEC. 2) THE SUM OF 125 PERCENT OF THE POWER SOURCES OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR WILL EXCEED THE AMPACITY OF THE BUS BAR [NEC 705.12(B)(2)] 3) EQUIPMENT CONTAINING OVERCURRENT DEVICES IN CIRCUITS SUPPLYING POWER TO A BUS BAR OR CONDUCTOR SHALL BE MARKED TO INDICATE THE PRESENCE OF ALL SOURCES. [NEC 705.12(B)(3)] 4) CIRCUIT BREAKER, IF BACK FED, SHALL BE SUITABLE FOR SUCH OPERATION. [NEC 705.12(B)(4)] PALMETTO PROJECT:38620 PIEDMONT AVE AUTHOR: EE N1 -GENERAL NOTES PHONE:+1 843-720-1844 MUNICIPALITY:ZEPHYRHILLS,FL DATE: 14/MAR/19 WWW.PALMETrO.COM CLIENT:J. HAYES REV:- 4tF RESIDENTIAL SOLAR PHOTOVOLTAIC SYSTEM a 38620 PIEDMONT AVE 0C,I ENERGY ZEPHYRHILLS, FL NEW AGE ENGINEERING 4.20 k v V DC +1 833 392 2887 14/MAR/ 1 9 208-888 DUPONT STREET PALMETTO E17O TORONTO,ON +1 843-720-1844 1505 KING ST EXT#114, CHARLESTON,SC 29405,USA SHEET INDEX Cl COVER PAGE NI GENERAL NOTES S1 SITE PLAN S2 PANEL LAYOUT S3 STRUCTURAL DETAIL El LINE DIAGRAM E2 ELECTRICAL CALCULATIONS E3 WARNING LABELS Al PANEL SPECIFICATIONS A2 RACKING SPECIFICATIONS A3 MOUNT SPECIFICATIONS A4 INVERTER SPECIFICATIONS A5 OPTIMIZER SPECIFICATIONS SYSTEM SPECIFICATIONS GOVERNING CODE: ING SYSTEM SIZE:4.20 kW IBC 2015 ALL WORK s A Bu M W"V* ' 172019 CODES FLOR MODULE:SILFAB SLA-M 300W IRC 2015 DIALCECTRIC CiTY OF INVERTER:SE3800H-US IFC 2015 ORDINATES .A1S EXAMINER OPTIMIZER: P320 NEC 2017 RACKING SYSTEM:SNAPNRACK 100 Cl COVER PAGE