Loading...
HomeMy WebLinkAbout19-21166 CITY OF ZEPHYRHILLS 5335-sTH STREET (813)780-0020 2116 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:21166 Issued: 5/01/2019 Address: 35885 SADDLE PALM WAY Permit Type: NEW SINGLE FAMILY DWELLING . ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 383,685.90 Total Fees: 15,775.19 Subdivision: SILVERADO Amount Paid: 15,775.19 Date Paid: 5/01/2019 Parcel Number: 05-26-21-0080-00500-0270 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,406 SQ FT APPLICATION FEES PLUMBING FEE 294.00 ELECTRICAL FEE 441.00 MECHANICAL FEE 205.80 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 2,074.20 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 ," �s � r Inspections' Re uired FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. A � x �Affllj &__ 6"�_ - RACtQM WMtUR E PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-35885 Saddle Palm way 3406 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,406 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 383,685.90 FEE SHEET $ 1,960.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 2,074.20 ELECTRICAL: $ 441.00 PLUMBING: $ 294.00 MECHANICAL: $ 205.80 SUB-TOTAL $ 3,015.00 TOTAL $ 3,015.00 SEWER: $ - na WATER: $ - na IRRIGATION: $ - TOTAL: $ - WATER METER: $ - na IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,568.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 159775.19 3SIFS-3— Lennar Homes-31SM Saddle Palm Way-3,40,E sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,406 $ 69.00 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 235,014.00 FEE SHEET $ 1,215.00 ADDRESS $ 30.00 DRIVEWAYI $ 45.00 BUILDING: $ 1,314.30 ELECTRICAL: $ 273.38 PLUMBING: $ 182.25 MECHANICAL: $ 127.58 SUB-TOTAL $ 1,897.50 TOTAL $ 1,897.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,450.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,657.69 FORM R405-201,7 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS VW SR Builder Name: Lennar Homes 0526 Street: 3 'Saddle Palm Way Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600�lG Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade,(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c. R= ft2 11.Duct s R ft? 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.33 159.00 ft2 SHGC: . SHGC=0.23 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 16.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.670 ft. Area Weighted Average SHGC: 0.249 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-bn-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 69.38 PASS Total Baseline Loads: 73.00 hereby certify that the plans and specifications covered by Review of the plans and fj T E is this calculation are in compliance with the Florida Energy specifications covered by this - p Code. calculation indicates compliance ' with the Florida Energy Code. PREPARED BY: Dave AU01 Before construction is completed C DATE: this building will be inspected for It ;. compliance with Section 553.908 hereby certify that this building,as designed, is in complia a Florida Statutes. with the Florida Energy Code. G'Op � OWNER/AGENT: BUILDING OFFICIAL: . DATE: DATE: - Compliance requires certification by the air hand r unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/22/2019 12:51 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 4 r FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS VW SR Builder Name: Lennar Homes 0526 Street: 35893 Saddle Palm Way Permit'Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2., Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2. 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. U-Factor: Dbl,U=0.33 159.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 16.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.670 ft. Area Weighted Average SHGC: 0.249 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 69.38 PASS Total Baseline Loads: 73.00 I hereby certify that the plans and specifications covered by Review of the plans and T_UE:ST,� Q ." this calculation are in compliance with the Florida Energy specifications covered by this4 p Code. calculation indicates compliance with the Florida Energy Code. �+ hrri a..:'?_. •,��,;�� �ti O PREPARED BY: JA') ye Aupich Before construction is completed r3 DATE: this building will be inspected for compliance with Section 553.908 n hereby certify that this building,as designed,is in compliance Florida Statutes. .S. with the Florida Energy Code. G'OD ll OWNER/AGENT: BUILDING%WI81- DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/22/2019 12:51 PM EnergyGaugeB USA Section R405.4.1 Compliant Software Page 1 of 4 i FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2606B sf ADS VW SR Builder Name: Lennar Homes 0526 Street: 35893 Saddle Palm Way Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County: Hillsborough(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2 b.Frame-Wood,Adjacent R=11.0 380.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2 6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2 a. 0-Factor: Dbl,U=0.33 159.00 ft2 SHGC: SHGC=0.23 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 35.0 SEER:15.50 c. U-Factor: Dbl,U=0.33 16.00 ft2 SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.670 ft. Area Weighted Average SHGC: 0.249 14.Hot water systems 8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation.features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.083 Total Proposed Modified Loads: 69.38 PASS Total Baseline Loads: 73.00 hereby certify that the plans and specifications covered by Review of the plans and a .Tk1ESxA ,.' this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. !. rirrr "%% '=f 'a� ��ti PREPARED BY: �l�V� (�l�tGl'l Before construction is completed DATE: this building will be inspected for . compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 � P , . -- with the Florida Energy Code. �!PD,•{NE1 OWNER/AGENT: BUILDING O lA14:0 19 DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an.Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/22/2019 12:51 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: 2606B sf ADS VW SR Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2576 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Hillsborough Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Vinyl windows,Shingle roof EWH CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 2576 20608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2576 20608 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 174 ft 0 2576 ft2 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2790 ft2 0 ft2 Medium 0.85 No 0.9 No 0' 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2576 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 2576 ft2 0.11 Wood 2/22/201 9 1 2:51 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Omt To Wall Type 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 18 8 8 149.3 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 67 4 8 538.7 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.600000 0 4 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 7 8 56.0 ft2 0 0.600000 0 5 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0 _ 6 N=>NE Garage Frame-Wood Main 11 31 8 248.0 ft2 0.23 0.01 0 7 E=>SE Garage Frame-Wood Main 11 2 8 16.0 ft2 0.23 0.01 0 8 W=>NW Garage Frame-Wood Main 11 14 6 8 116.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.812 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Vinyl Law-E Double Yes 0.33 0.21 N 16.0 ft2 5 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 2 E=>SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 3 E=>SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 4 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 92.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 5 S=>SW 4 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft2 3 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5 6 W=>NW 5 Vinyl Low-E Double Yes 0.33 0.23 N 12.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 7 W=>NW 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 674 ft2 674 ft2 57 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 2404.3 131.99 248.23 .2649 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1 2/22/2019 12:51 PM EnergyGauge®USA.Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1050 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 515.2 ft Main 128.8 ft Proposed Qn Main —cfm 77.3 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cool!n Jan Feb ar Aprr JM ing Jan ]Feb f X�M ss:p Ooctt Nov Dec Heat ar A Jun Ju Au Apr May rl Jun Jul Au Jun rl Jul ri Aug ri Sep Oct Nov Dec Nov € Dec Venting Jan Feb [X Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 '78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 1 st Floor Default(8 Ibs/s .ft. 0 ft2 Oft 0.3 2nd Floor Name: Signature: Rating Compant: Date: 2/22/2019 12:51 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4 2017 EPL DISPLAY CARD ENERGY'PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 95 The lower the Energy Performance Index, the more efficient the home. 1. New home or,addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b)Return ducts R 6.0 c)AHU location Attic/Main 3. No.of units(if multiple-family) 3. 1 4. Number of bedrooms 4. 4 13.Cooling system: Capacity 35.0 a)Split system SEER 15.5 5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER c)Ground/water source SEER/COP 6. Conditioned floor area(sq.ft.) 6. 2576 d)Room unit/PTAC EER e)Other 7.Windows,type and area a) U-factor:(weighted average) 7a. 0.371 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.249 14. Heating system: Capacity 34.6 c)Area 7c. 215.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE f)Other 8.50 9. Floor type, insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 15.Water heating system c)Concrete, raised (R-value) 9c. a)Electric resistance EF 0.95 b)Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A. Exterior: d)Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g)Other 1.Wood frame(Insulation R-value) 10131. 11.0 2. Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a)Ceiling fans a) Under attic 11 a. 30.0 b)Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d)Multizone cooling credit d)Radiant barrier installed 11 d. No e)Multizone heating credit f)Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed.(or exce ed)in this home before final inspection. Otherwise, a new EPL display card will be completed based on insta ed code compliant features. Builder Signature: An 0 Date: APR al Address of New Home: 35893 Sadie Palm WE City/FL Zip: FLZephyrhiIls,FL 33541 2/22/2019 12:52:44 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Building Anal Job: 2606Bsf ADS VWSR g Y$I$ Date: 3I7/2019 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(°F) 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftZ Btuh % of load Walls 5.0 10504 31.3 �«s Glazing 21.3 4555 13.6 wall nfiltrafion Doors 19.6 746 2.2 Ceilings 1.3 3231 9.6 Floors 2.9 7385 22.0 Infiltration 2.2 3433 10.2 Ducts 3687 11.0 Floors Piping 0 0 Humidification 0 0 Glavng Ventilation 0 0 Doors Ceilings Adjustments 0 Total 33542 100.0 Component Btuh/ftZ Btuh % of load Walls 2.4 5107 18.1 walls Internal Gains Glazing 46.7 9987 35.4 Doors 15.4 584 2.1 Ceilings 1.7 4468 15.8 Ducts Floors 0 0 0 Infiltration 0.4 714 2.5 Ducts 3602 12.8 - Infiltration Ventilation 0 0 Internal gains 3750 13.3 Blower 0 0 Glazing Ceilings Adjustments 0 Total 28212 100.0 Doors Latent Cooling Load= 3245 Btuh Overall U-value= 0.090 Btuh/ftZ-°F Data entries checked. I -Fp- =i-ghtsc ft- 2019-Mar-07 14:33:09 ACC ^�^• Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ipment12606 sf ADS template VW 3ton Carrier.rup Cale=MJ8 Front Door faces:SE Project Summary Job: 2606B sf ADS VW SR 1 •7 Date: 317/2019 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Notes: Vinyl windows Shingle roof Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 29855 Btuh Structure 24610 Btuh Ducts 3687 Btuh Ducts 3602 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none -(none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 33542 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 28212 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2481 Btuh Ducts 764 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ft2) 2576 2576 Equipment latent load 3245 Btuh Volume(ft3) 21723 21723 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 31457 Btuh Equiv.AVF (cfm) 80 40 Req. total capacity at 0.85 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade PERFORMANCE 15 HP Trade PERFORMANCE 15 HP Model 25HBC537AO030 Cond 25HBC537AO030 AHRI ref 10487322 Coil FX4DNF037L AHRI ref 10487322 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 29750 Btuh Heating output 34600 Btuh @ 47°F Latent cooling 5250 Btuh Temperature rise 26 OF Total cooling 35000 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 32 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigjfttsoft® 2019-Mar-07 14:33:09 ^w^r a• ^• �� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...ipment12606 sf ADS template VW 3ton Carrier.rup Calc=MJ8 Front Door faces:SE r o Manual S Compliance Report Job: 2606E sf ADS VW SR p p Date: 317/2019 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson -Project • • For: Lennar Homes Cooling'Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 28212 Btuh Entering coil DB: 75.5°F Outdoor design WB: 77.3°F Latent gain: 3245 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 31457 Btuh Indoor RH: 50% Estimated airflow: 1200, cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: • SplitASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Sensible capacity: 29750 Btuh 105% of load Latent capacity: 5250 Btuh 162% of load Total capacity: 35000 Btuh 111% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 33542 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L Actual airflow: 1200 cfm Output capacity: 26719 Btuh 80% of load Capacity balance: 32 OF Supplemental heat required: 6823 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. wrightsc ft- 2019-Mar-07 14:33:09 .dR.�..m .ow. Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1- ..ipment%2606 sf ADS template VW 3ton Carrier.rup Calc=MJ8 Front Door faces:SE PASCO COUNTY, FLORIDA Permit No. 211 Date Permitted Builder Name/Owner Names 5 Control# . County Parcel No. SubDIV: AddresslLocation 05,626,5 Classificationfrype of Use cSi}'lGle y��m. TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:3;4a 4 � Exempt n Yes [l No How Determined I Impact Fee Amount $ �� Zone No. TAZ: I SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7,, 14 y (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt "Yes n No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ -76—F,6,1 Exempt ❑Yes ❑ No How Determined . LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt []Yes ❑ No How Determined Total Amount _ RESOURCE FEE ERU TOTAL AMOUNT Prepared By LbT:�4= Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the condltions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-780-0020 City of ZephyrhillsPe[mit �»0��mo &o�\k��toO »»�"u Building Department ' Date Received Phone Contact for Permitting xnuuxu xI I Lxuux�- xouxoun " Owner Phone Num�v owner's Name Owner's Address 4600 ress FL 33607 Owner Phone Number Fee Simple Titleholder Name owner Phone Number Fee Simple Titleholder Addimss N/A JOB ADDRESS 135-68�Sa_d_dle Palm Way LOT# Silverado Ranch Subdivision Ph 6,8,9A SUBDIVISION PARCEL/v*105-26-21-0080-00500-0270 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW cowsm xDDx�o' �--1 G|om �--1 �--\ DEMOLISH INSTALL R REPAIR OTHERPROPOSED USE SFR COMMF--� TYPE OF CONSTRUCTION BLOCK FRAME STEEL DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure/Pence BUILDING SIZE sitt 06oTAGE- 1,/IBUILDING $ VALUATION OF TOTAL CONSTRUCTION �^�ELEuTn|uAL F��—1 PnoGREOSENEeGY F—� ��R.E.C. ��� AMP SERVICE OPLUMs|NG J—���E�HAN|[:\ VALUATION�� / u°� . �� SPECIALTY[--lgAG �� ROOFING �—| SP�o|� � F--� OTHER ^��' �—� �--1 FINISHED FLOOR ELEvAT0NG FLOOD ZONE AREA DYES | No - - - - - - - - - - - - - - - ou|LDsR COMPANY FLennar Homes,LLC o|amxTume REGISTERED _Y/ N 'EE:«wnE» LYLNL_] 4600 Address License# sLEuTmoxm COMPANY I Edmonson Electric, Inc. m|amATumE REGISTERED Y/ N Fss«unnsN L_lLNL_| omumms Uoanmn# PLUMBER COMPANY I Bayonet Plumbing, Heating & AC, SIGNATURE REGISTERED Y/ �— rss«»RnEx LY/NLJ Address Uoonaa# MsCMAm|oaL COMPANY =Bayonet Plumbing, Heating &AC, Inc a|mm4TumE GISTERED Y/ N _| FEsuunnsN L� /N_J Auumas License# OTHER COMPANY C=Sterling Quality Roofing, Inc a|Gm*numE REGISTERED L_l/_N_] Fssu»nmsN L_Y/NLJ xuumss 4211 Shoal Line Blvd, Spring Hill, FL 346 Ummso# xuxoomunxmxxmxxoxuxxuxnmuxnmnxmxuu � xxmxxxuxxmxxumxxumxumxxumxxmnxuu RsS/DBuTu& Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1N working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wt Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach V4sets of Engineered Plans. '~ °~`PROPEnlY SURVEY relbired for all NEW construction. Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) � Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy vf contract required) Ramofsifshingles Sowers Service Upgrades A/C Fanoou(P|uVGumny/roota0e) Driveways-Not over Counter ifon public mauwxgm'nomdaROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 17.03) OWNER OR AGENT ,AAI Adieu CONTRACTOR Subscribed and swo ( r affirmed) efore me this Subscribed and swor (or affirmed)before me this u r-iviar-1 y by Ashlee Callahan 07-ma,-19 by Ashlee Callahan Who is/are personally know hasihave PFGdUG Who is/are personally known to me or hasfhave predeee� a entification. s identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa'M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped E -- 1II1ShM.Wi9mPl ratrtnMpP�l�4T ( . , �IC�Rn�ta!atnMpP� ?. � �,�.M#�1JuMi�,��� bead.�twrsyr{tetU�al�i0s�l�;iVtl 9i�7�1BYrJTa�F+t�1St1F996114t�717�(1! - - INsTR#2019063083 OR BK 9889 PG 3752 Page 1 of 1 04/16/2019 10:36 AM Rcpt:2046188 Rao:10.00 OS:0.00 IT:0.00 Pau(a S.O'NeiC,PFL2).,Pasco County Clerk&ComptYOQ67' Permit No. Parcel ID No 05-26-21-008M0500-0270 NOTICE.OF COMMENCEMENT state of Florida County,of Pasco THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and In accordance wfih Ctlapter 713,Florida Statutes, the following Information Is provided In this Notice of Commencement: 1. Description of Property:Legal SILVERADO RANCH SUBDIVISION PHASES 6.8&9A PB 75 PG 75 BLOCK 05 LOT 27 street Address: 35885 Saddle Palm Way Zephryhilis FL 33541 2. General Description of Improvement Single Family Residence 1 Pool I Screen Enclosure/Fence 3. Owner Information: Lennar Homes,LLC: 4600 W Cvoress St Ste 200 Tampa FLU 31607 Addreae City state Interest In Property. Name of Fee Simple Titleholder. N/A (If other than owner) coractor Lennar Homes,LLC city state 4. contractor Name 4600 W Cypress St,Ste 200 Tampa FLU 33607 Address city State Contractors Telephone Na: 813.574.6700 S. surety.ow N/A Name Address Cfiy Stfltm ®� ® .o Amourd of Bond: td Telephone No.: 8. L'ender; NIA Name p Address Clty• ' State w..*fit Lender's Telephone No.: o� ` ,y7 .0 ca k s� 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by A' �ig` .; V Section 713.13(1)(a)M.Florida'Statutes: �'"gam Lennar Homes.LLC• Name 4600 W Cypress St,Ste 200 Tampa FL-33607 f Address City State e� M af Telephone Number of Designated Person: 813.574.57013 r, 8. In addition to himself,the ovmer designates N/A of LU to receive a copy of the Uenore Notice as provided In Section 713.13(1)(b),Florida Statutes. Z C) T Cr W Telephone Number of Person or Entity Designated by Owner: 4 W LL co W J J CJ 9. Expiration date of Notice of Commencementd is one year from the datteRof recording unless a different dale is specified: (f) Z U F- Q IL ARE WARNING TO CONSIDEREED OWNER: PAYMENTS ENTS N ERTMC OWNER 71AFTER PRART I SECTION 713.13N OF TMFLORIDA STATUTESOF AN COMMENCEMENT `l' O W N LLU. RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTH OF-COMMENCEMENT MUST BE (L LL1 W U) RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING CONSULT o WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENC&ENT. L, �t) —1 STATE OF FLORIDAE W � W U COUNTY OF PINELLAS "' _ 0 LL ud Signature of Owner or Owner's Authorized Officer/Olrector/Partnar/Maneger o W O Vice President _ I,—) U Slgnatorys^^111le/08ice F— The foregoing Instrument was acknowledged before me this day of March`r0lq. ,by Fa � r C m AIL Steve Hobert Smith. as Vice president (type of r,truateo,attorney in fact)for n-e a omes LLC (name ofpe o of whom Inatrumentwas executed). .i W O QPersonalty Known■O$Produced Identification❑ Notary gnu L_ O OType of IdentfilcetionProduced Name Pdrn) .Ellssa Holleran C I— z'Verification pursuant to Section 92626,Florida Statutes. Under penalties of J perjury,)declare That I have reed tha foregoing and that the facto elated N � � W �8 are true to the best of my lowMedge and belief. LL EI�881111:H011�I1AN Slgnahrre of NaftuN Person SlgnIm Above ' Gafini(dan1lFFNtiAl11 . . E1gkwJuerD,1010' '' wirdatelbcsibrafarml; bla�+nxrn.lrrawurr.i(oftiwwtltsi. PLOT PLAN SKETCH ONLY SEC. 05 TWP. 26 S. RNG, 21 E. NOT A BOUNDARY SURVEY LOT 27, 'BLOCK 5 BEARING BASIS: SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A WEST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E PASCO COUNTY, FLORIDA. T� THIS SURVEY IS SUBJECT TO ANY FACTS THAT PRELIMINARY DRAWING: N MAY BE DISCLOSED BY A FULL AND ACCURATE THIS PLAN IS FOR PERMITTING PURPOSES TITLE SEARCH, ALSO SUBJECT TO SETBACKS, ONLY, NOT FOR CONSTRUCTION. VERIFY 1 TRACT E EASEMENTS AND RESTRICTIONS OF RECORD. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. /CONSERVATION AND M UNDERGROUND FOOTER, STEM WALL, AND LEGEND: ! AREA p UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. PROPOSED DRAINAGE FLOW 'N—WETLAND (00.00) = PROPOSED GRADE J LINE DO NOT SCALE THIS PRINT, DIMENSIONS AND E-00.00 = EXISTING GRADE / ! U NOTES TAKE PREFERENCE. NOTES: j Cn CERTAIN DATA SHOWN HEREON BASED ON �V FLOOD ENGINEERING PLANS PROVIDED BY CLIENT. LOT GRADING TYPE = B �' a ZONE PROPOSED PAD ELEVATION = 106.2' X. STRUCTURE TEES SHOWN HEREON DENOTES FRONT SETBACK = 20' j f � MEASUREMENT FROM FORM BOARDS/FOUNDATION SIDE SETBACK = 7.5' REAR SETBACK = 15' � /• � R.OQ° 70 PROPERTY LINE. / I ZONE * = 10' UTILITY EASEMENT o`V •A„ ON LOT AREA CALCULATIONS LOT = 8261.41 SQ. FT. LIVING AREA = 2278 SQ. FT. ^0 ENTRY = 126 SQ. FT. GARAGE = 617 - FT. COVERED LANAI =NA SQ. FT. `♦ ` PATIO = 32 _SQ. FT. POOL AREA =�ASQ. FT. CONC. DRIVE = 559 SQ. FT. lot \ T ACT E y`;.• S LOT 26 A/C & CONC PAD = 12 -0. FT. \\ \ BLOCK MMON AREA s 5 PRIVATE SIDEWALK = 31 -SQ. FT. gyp. IMPERVIOUS = 44 s� __ 96 \ \\ D = 3655 SQ. FT. SOD = 4606 SQ. FT. OFF LOT AREA CALCULATIONS \ \\ \ RIGHT OF WAY =_1172.66 e _SQ. FT. \ DRIVE APRON = 352 SQ. FT. .` TRACT E \ (�p4`20,I �i�'� PUBLIC SIDEWALK = 327 SQ. FT. FLOOD COMMON AREA \ 30 •s SOD = 494 SQ. FT. ZONE \ 8. '3 }' TOTALS „X„ > DRAINAGE v ,Q, EA EMENT \ h� AREA = 9434.07 SQ. FT. LOT 27 DRIVEWAY =_911 SQ. FT. FLOOD< �, \\ \`(1d6 to) BLOCK 5 Q\S g SIDEWALK = 358___SQ. FT. ZONE •.\ \\ .$�a oy� 4OaG1'C SOD = 5100 _.SQ. FT. A' >> ••.cos �\ �s• dti�. ��: Q \ aArA "Y (105.17' �J CLEAR_/\\ �: f/ TRIANGLE CURVE RADIUS ARC CHORD BEARING DELTA C122 718.97 120.67 120.52 N 39.3415 IN 1 09'36 57 PROPOSED: C126 225.00' i 5.55 15.55 S 43-45 2B W 03.57 37 0139 1 26.00' 1 7.14' 7.11' 1 S 49.57'25" W 16'21'30" LOWEST FLOOR ELEVATIONS: LIVING AREA: 106.90' DESCRIPTION: GARAGE AREA: LOT 27, BLOCK 5, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION. ELEVATIONS REFERENCED TO PHASES 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 NORTH •AMERICAN VERTICAL THROUGH 080, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. DATUM OF 1988. MEAN SEA LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X & A" COMMUNITY PANEL NO, 12101C 0288 F EFFECTIVE DATE: 9/26/14 Project Number: Square Feet: 8261.41 t LENNAR HOMES LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, @- CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH- CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET-NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE W F= WOOD FENCE JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SM SURVEYORS AND MAPPERS Checked By. 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA,34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: r� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 2/15 19 JBS 02 fB 2-W THE ORIGINAL RAISED SEAL OF A FLORIDA OfSIGRE DATE LICENSED SURVEYOR AND MAPPER JOHN BEACH Revisions: FLORIDA EG. LAND SURVEYOR No, 2984 LB 4493 JEFF M. H RTLEY AL SURVEYOR & MAPPER Na.7123 OT3.280 ga: o- _ s s �! .� tl Q, , 11'PE:B � P 7dP.10.1.:4 --� E.B r -��`�. �g 7c,9 •'. ;�GZ4, ,'". '� - 1 •• � /�/, .`. z.. _ gf42 �- Oa: �' ." 6 8:7�. �g �35j ji ,�`.. �nr6�0 , i �� - Xtoo. _105 ai lXss r` iLggCT.: --- - tt,� .. �' g .` �cj• `' ti`. ,00fi; T)'P� B . �,�.• '�;♦ - '; ,;�, Gc�,j�S' do •: t . ,, ,..{�' _ �,- },. 4:8 q � � .. •,, {,+' :1 . 1 .00 01 . � ,s. ,y a�z� •�' ;F�,�1''`s'��', x6����.42,1' �. M ,�p1-. �-9 --- __1 4 F'�',�` 2 r ' '. �r - •'„. �"._ ' ' 49 7 .�' d'. ,J!PE B<` • C�6y ` a o4. �. � '�.'' t",'' � �, s' '{�� -r..©.a 'r g-` ` ,AD'100,4 ri :,1 a; ;g"�• . , lu I �'. j \ a.` a - ' /--.:-_ ��'• 11 AG'�: 1 ` a FFa10.1:30` g$5 (/ '��' oi-V 20 b pAO�106 6 ZAD ,� ` g .37 '` 7YpE ',aor LOT 1 Z?i 06.3 FF=1.Of 9 0 c` Cfl '.50 COT -3 0 �0 '` 7 ,3�pAD'T a$ ,. 0 D A. . 01.76'` +. °a.p Lo.T 17 O's}' ;9*_�. Az F7RU.='jOj kjA IN 7 }? FF026. '7, PAD`1013 h TY '� �. TYPE A FFl Ov PAD_; , , 05-26-21-0080-00500-0270 1 Pasco County Property Appraiser Page 1 of 1 Due to a software conversion, changes in ownership and sales may be delayed. Data Current as Of: Weekly Archive - Saturday, January 12, 2019 Parcel ID 05-26-21-0080-00500-0270 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $2,966 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 35885 SADDLE PALM WAY ZEPHYRHILLS, FL 33541 Just Value $2,966 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,966 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 5 Taxable Value $2,966 LOT 27 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _ Use _ IDescription,Zoning jUnits __Type Price ^iCondition_Value _ 1 0100 1 _ SFR I MPUD I 6,000.00 SF_ _ $0.40 1.00 , $2,400 2 I 0100 j SFR MPUD 2,262.00 SF $0.25 �_1.00 $566 Additional Land Information _ Acres i 0.19 Tax Area 30SI l FEMA Code I -- Residential Code i SLVRCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line jDescription jyear jUnits _ Value No Extra Features Sales History - See All 6 sales Previous Owner: ------ — - --- --------- Month/_Year Book/Page Type _ _ ,DOR Code_ Condition4Amount___ 04/2019 9888 / 0446 _ _Warranty Deed _ _ 1 05 Vacant 1 $104,000 05/2017 19535 / 0 - I Certificate of Title _—' �— 05 Vacant ;Multi-Parcel Sale 11/2016— 19462 10384 (Mineral Rights or Royalty Transfer] 05 Vacant IMulti-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080005000270 5/1/2019 PASCO COUNTY P A BUILDING CONSTRUCTION SERVICES 8731 Citizens Drive Date:7/12J20119 COUNTY FLORIDA Suite 230 0imN SpAcEs.Vmmmr.PrAcEs. New Port Richey,FL 34654 727-847-8126 NOT A PERMIT Receipt#: 1874187 FEE DESCRIPTION ACCOUNT COPE UNITS INVOICE 0 FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1478833 $33.66 $33.66 1874187 7112119 Waste Single Family 35885 SADDLE PALM WAY. TOTALS: $33.66 $33.66 Receipt Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Arnt Paid 1874187 Check 01257324 EBESS BCCCP58W 07/12/2019 $33.66 Total Payments: $33.66 EU-01 Address Phone LENNAR HOMES LLC TAMPA DIVISION 4600 WEST CYPRESS ST STE 200 TAMPA,FL 33607 Comments: 3588.6 SADDLE PALM WAY While you will be paying your bill with Pasco county Building Construction Services,the full amount of the credit card or e-check fees,NOT shown above,is collected by First Billing payment services. myreports/reports//PASCOPROD/PASC0/ReceiptAA,_V7.rpt 7112/2019 Page 1 of 1