Loading...
HomeMy WebLinkAbout19-21295 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020: 21295 ELECTRICAL PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit#:21295 Issued: 5/30/2019 Address: 5024 20TH ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 47,511.00 Total Fees: 420.00 Subdivision: SUMMERHILL Amount Paid: 420.00 Date Paid: 5/30/2019 Parcel Number: 12-26-21-0100-0000-0020 CONTRACTOR INFORMATION OWNER INFORMATION Name: GREEN MINDED SOLAR LLC Name: MARTINEZ ANA COTO & JOSE Addr: 3350 ULMERTON RD #9 Address: 5024 20TH ST CLEARWATER, FL 33762 ZEPHYRHILLS, FL. 33542 Phone: (727)464-3888 Lic: Phone: 813-838-6848 Work Desc: INSTALLATION ROOF MOUNT SOLAR PV APPLICATION FEES ELECTRICAL FEE 420.00 INSPECTIONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER \ ^ FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. CONTRAC PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER o City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �� 911� QO1 S�If, Date Received: Site: nn Permit Type: V Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ r This comment sheet shall be kept with the permit and/or plans. MAY!` 2 8 2019 BiltBurg —Building Official Date ntractor and/or Homeowner - (Required when comments are present) CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 21295 ELECTRICAL PERMIT ,PERMIT INFORMATION LOCATION INFORMATION Permit#:21295 Issued: Address: 5024 20TH ST Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRICAL MISC Township: Range: Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section: Sq. Feet: -��1. e: Book: Page: Cost: .00 Total Fees. 420.00 Subdivision: - _ ILL_ Amou aid Date Paid: Parcel N er: 12-26- 1..l -0000- C NTRAC OR INFORMATION OWNER INFORMATION Na e: GREEN MINDED SOLAR LLC me: MARTINEZ ANA COTO & JOSE dr: 3350 ULMERTON RD #9 A dress: 5024 20TH ST CLEARWATER, FL 33762 ZEPHYRHILLS, FL. 33542 hone: (727)464-3888 Lic: Phone: 813-838-6848 or Desc: INSTALLATION ROOF OUNT SOLAR V APPLICATIO FEES EL CTRICAL FEE 420.0 a INSPECTIONS REQUIRED. ROUGH ELECTRIC CONSTRUCTION POLE PRE-METER FINAL C—C) n r . REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute S53.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. CONTRACTOR PER OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER reGreen Minded S Wa Solar,LLC •. _. ...,,_ 3350 Ulmerton Rd #9 Clearwater FL 33762 r Phone Number727-464-3888 Contractor's Authorization Letter I, Shane J Kelley , license holder for Green Minded Solar, LLC authorize the following people to apply/sign for permits under my license number EC13007555 Please allow ONLY the person(s) listed below to sign. This letter supersedes all others. Jared Ackerman Mary Morrissey Contractor's Signature Contractor's Printed N e The foregoing instrument was acknowledged before me this ��� day of P6Z , 20_j'�7(_ by ak who is personally known to me or has produced as id e n. �- Brandon Wright NOTARY PUBLIC NO ARY B a STATE OF FLORIDA Comrt##GG054353 Expires 115/2021 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 828 333--0781 Owners Name Martinez,Ana Coto Owner Phone Number 813-417-8265 Owners Address 1 5024 20TH STREET ZEPHYRHILLS,FL 33542 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5024 20TH STREET ZEPHYRHILLS, FL 33542 LOT# SUBDIVISION Summer Hill PARCEL ID#1 12-26-21-0100-00000-0020 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = = DEMOLISH X INSTALL a REPAIR PROPOSED USE = SFR 0 COMM = OTHER Solar PV Installs on(10.03kW) TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Roof Mounted Solar PV Installation (10.03k" BUILDING SIZE SQ FOOTAGE 686sgft HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $47,511 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ 9r =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION l " =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO �C-. . . . .... . .. . . . . . ... . . . ...r..-.���T. r .... . ..-. .,. . ...4 . .... ..-. . ... i-. . . . . .... BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# EC13007555 Shane J Kelley ELECTRICIAN COMPANY Green Minded Solar, LLC SIGNATURE I REGISTERED I Y1 N FEE CURREN I Y/N Address 3350 Ulmerton Road#9 Clearwater,FL 33762 License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# 1111111111111111111111111111111111111111111111111111111111111111111 ' RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07,as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter, or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF PQMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Brandon wf�f�llt Subscribed and swom to(or affirmed)before me this Subs ed and om to(or affirme�)pef a me this �� y" by J 10 (� by �hc�ttie Y���e y �, NOTARY PUBLIC Who is/are personally known to me or has/have produced Who is/are personallykrfl to me or hasfhaxd produced ?;STATE OF FLORIDA as identification. as identification. Comm#GG054353 CE rep° Expires 1/512021 Notary Public Notary Public Commission No. Commission No. Bzipp1.) c.()eroc— t Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped r n. Green Minded Solar,LLC in e'd 3350 Ulmerton Rd #9 Clearwater FL 33762 Sola r Phone Number727-464-3888 Contractor's Authorization Letter 1, Shane J Kelley , license holder for Green Minded Solar, LLC authorize the following people to apply/sign for permits under my license number EC13007555 Please allow ONLY the person(s) listed below to sign. This letter supersedes all others. Jared Ackerman Mary Morrissey Kai OL Q±r�&V, Contras ors Signature Contractor's Printed Nam 3 The foregoing instrument was acknowledged before me this � day of 20 ('� by C{lUleLeue-o who is personally known to me or has produced as entif a ' n. Brandon Wright NOTARY PUBLIC NO ARY PU LI o �STATE OF FLORIDA Comm#GG054363 S/wE 1v�t Expires 11512021 INSTR#2019093490 OR BK 9916 PG 1 202 Page 1 of 1 06/04/2019 02:31 PM Rcpt:2060291 Rec: 10.00 DS:0.00 IT:0.00 PauCa S. OW66 Pf.D., Pasco County CCerk&CmnptroCCer This space for use by Clerk of the Circuit Court only. NOTICE OF COMMENCEMENT Permit Number. Tax Folio No. 12-26-21-0100-00000-0020 The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in the NOTICE OF COMMENCEMENT. 1. Legal Description of property(street address required): Single Fami(y Residence 5024 20TH STREET ZEPHYRHILLS,FL 33542 2. General description of improvements: Roof Mounted Solar PV Installation(10.03M 3a. Owner Name:_Martinez.Ana Coto Owner Address:M2420TH STREET Z.PHYRHILI R FL 33542 3b. Owner's interest in site:_Owner 3c. Fee Simple Title holder(of other than owner) Address: 4. Contractor Name: Green Minded Solar LLC Address: 3350 Ulmerton Road#9 Clearwater.FL 33762 Phone: 828-333-0781 5. Surety Name: Amount of bond: Address: Phone: 6. Lender Name: Contact: Address: Phone: 7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)7,Florida Statutes. Name: Address: Phone Number. 8. In addition to himself,Owner designates the following person to receive a copy of the Lienoes Notice as provided in Section 713.13(1)(b),Florida Statutes. Name: Address: Phone Number: 9. Expiration date of Notice of Commencement(expiration date is one(1)year from date of recording unless a different date is specified). WARNING TO OWNER ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF TILE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCE. . Signature of Owner or Lessee,or Owner's or Lessee's Authorized Officer/Director/Partner/Manager i Signatory's Title/Office SPATE OF FLORIDA COUNTY OF t The foregoing iinnst1ru_ment was acknowledge before me this day of J u u � by <IITo O.r�i A ,as for Personally Known OR Produced Identification Type of Identification Produced Signature-Notary Public Under penal'es of perjury'I declare that I tave`iead the foregoing and that the facts stated in it are true to the best of my knowledge and belief. Signature of Natural Person Signing Above W COMMSM W (A copy of my bond mart be anwhed at the time of momdation of mib Notim of Commencement) INME :M 19,210 sled 29NOV2012 V— D gar ti ttG0*let so(11i1ffm "' %\ STATE OF FLORIDA, COUNTY OF PASCO o�THIS IS TO CERTIFY THAT THE FOREGOING ISA ' RUE AND CORRECT COPY OF THE DOCUMENT '` FILE OR OF PUBLIC RECORD IN THIS OFFICE " in ggod bve7wt ® ITN SS MY HAND AIJD OFFICIAL SEAL THIS DAY OF Q 2 AULA S.O"NEIL,CLERK&COMPTROLLER DEPUTY CLERK i 9 8 7 6 5 I 4 I 3 I 2 I 1 NATIONAL ELECTRICAL CODE,NEC(2014) ENGINEER n ALLEN GEZELMAN A 16502 HANNA RD. A LUTZ,FLORIDA 33549. PH.813 909 1956 Allen@GezelmanPE.com www.GezelmanPE.com PE 59180_ fi` s� ■ solar SE3110N-1�/SE ItOON.OS,SE5088H US/SEl900H.118/ I600H•UE solar- • : solarEdp Power Opthnlzer .a 51 rra■ Lss.oawr..■.lrwr.rrrw.a■..+rra.rr.ala� Modils Add-On for North AnN•icu 'FBPE t■� �_- a r■a.. e.rr.ar — .a wnr..,■r.. • P300/P320/P370I P400/P405 - 8 ., i.r■r s»asr.t�a»r•tnarr w.ewHx su�sxan ussoxals Lwow us s[nesws p3 p ►970 p� O.raa.67w.3.alr.rWtlrc.r0 OUTPUT - Owaa.nw P.W 1,+ Y..anII_Idw.r■w err . war►cN.uJralee..a a twswauo..0 w !c�!!1. ................. ?.......:.. ........, woe . ...I w -drarx . e ..-- r ..� + .. _.+ ..._....I................. ........ ...t xw•..... r w AYCY1Ym-ft_MMV~!- ac an ( .ra O _ s .K 9! .......................................... » !C ° Y to p 1ss we 3< .. ..' . . . ,... -r s-Y .•a. ssa.y. vk ...u 1........ I........ I........m ass m m m 6a ......... 0 n a........ R........ ...1. • .a. on itAi w..a lnls mae .................. . .. ......... .. ... ,wr.n aerp;6,ow e.......................i s:. L.................. ....................................... .......:.:.............. ..... �.lr/M■al■ttLi.■■Nho1r.■■ ........... *■■.■wll-' - L M Y.N iYl -a.N YL tl�0 YJ{ _ O rrrrw v w us ue ue Sao sr an 1 0.11m inee.9................................. w v -_ - - oc...... eoo 7r�o __ ___ wi n■aa► T A *10 lt.a I..15 Yaa 7Yi .riff .M}Q!!4!L._�R�Y ...............:..............: ................................................................:. 12000....... ....W...... ButtYtaUYlra/1M71D11 a►ti z1.OeNM[tlWmol016aM SeU1WQ M t aq aY3._— alas.-_-..ur .HA .lU .lU I/.Oe■.e .... YO •. .......m CtJ a� B�IIrO�rM " !................... YO w 1■■..w .rutMlrr....... - ).........R.... ..... O Z C --__-, _. __. -_-- - _ __-_. ,g!n!rtxr}sting! PU!..........:....................................................... ..I ...................................................................... rr■w ti pe ara aaa7 aw --ta/A a.tt a.a ■ .i.ipec..w.awr`...................... - - n,+ - .s wlwlraurwauwo ornrmla■wn�nar�uuxoaarmewl:ou.eoerrvaml N ..............................................................:.................................................. N a ■.ra..r r is aat aat tct au as sm .rrriy.eir..i is as I lea ias ' tas n sal °mpw'r 1 w. Q O ........................................................................................................................................ j w _ tp.r.atr�► u IS loft nw rs nA. nn x« ra�saq!ladigs............... Y 'r sswos..ae■wuaa O 0 N • awrrw IN to :o .11 i110 » zw .a eac_, �actiwcr4caaooa;�cs>smaa X1.1 .hM�}: 4�rrt.41!nlea.................................. !4> r......-............ ............................................... ........... ....... ........................................... wi.�■nr• w at.ta two aim nst u:n aati ......... m9............................ .................!KmaiM-n!..!. !wa .... ................. •w.■arsrwrl.N •.w..rr�s■r■.u¢rn tlwwR.Rw■rr■tN 'wrrarrr.rr ..k!t!p!1llM.. lPAf.........:..................... ........................................!!:#..........................................:.N...... rw wi O (J agltwrawr.rr rsrnwtaaw��.a .gc!! u+r!�l ex.................................... :!!.........................................,..:...... ...?�...... Q O 3 - lt.. <� w ............. O lom >,r —r MI�IMfr .tit __•____�-___r___�--___. . wMlaa3 Z �• �_.-� _- Mr yflr.l�rrAriY1R = i .YM1M......r N10Y1 ��I.1�Wn1M�I.1.Y.N. O '� .+ r±.cwn! r!p!r8.rr.!...................... r.grwn!5.?�!!J!.?m4 mr�x+!!ri..... m:ai:u! ia.m■�ei i — ar,ra■r u-atao ahwwAlm W.L■w iL■ssl■f/A/..sA/.Lw mJM N O - ■rrwrr.r wrsww. �- ...................................................................................9!!!!!r!!............................ .... .... ......... .... .... ... ............ s. .lar ■in. O 3 ................ ... ........... ;... L................. g ------1 , a.r.aM.a...•lassla■rs•7aaes ar.rr■a.r.aire.-,..Kawia..n.r L. .1. U '! w`�.'�'i.r""�'i..+.rr.`.... -—r aauie.romawiLl■a !!►krMLi� I ........ ........*a� ::::.. �..... �........ (....:........1►l....... 0 0 .....uw,.«.mr..r,.. 4 t _ .:... t!!+1.. .....,. w............................. ...i!u?�4 ?M �1�a1 �4!�A !Floxu µm....... ........ .Iw..ta..r. ruo. ".ucatira. '• -..x.e }4.4.ds_.........................._.............. .............................. +!? ......!!.4�! o.rrel/ 0 M rnlw�. rxlresso./ Ay■wat?M1Q-.W V."Mrft*WA0epw. Na/ oorr...rr{Lwc.". k wu.r .■..rr-.w..r xaaiuialorsswaunols .................I................... ......._ MpP44 mik.......................................... J �.'"�. ■' .�.s.�.n"�■--sle+ra .Ka ee..resr/.!!!o"!!' a7sYo.rR 1"Aw R e!M►4�N................... s+4I� 3?Lh+.................................1..R.._ Q LL i ......................................... . .. . ...... .......... :41PA!......4......!A!!.M! ...................................................i? /. :.?l14................................................cl. ,...3 le0ewnwsrl.rad - .... ................... d`r.:rivarnaw..................... .....i.�sia�.u,�+oxrw:vi r/. ... n.rsn�+.........................................,...............................:.!!gL!rw!w�.........,..........................,.......................... Z r-.r■- . ai.. ..a eV.ftv1.rrrr nrw-_. ._ ea ........ N! awe ai iiw ou sss a a-iw s r r.r.nrrrrn. trw '°m w��+w.r+rn� mr tw main 111.5465.30 W4w!!n!.11!.!e/...................................................... 1.to................L....,.../........ L...........................:............./.Mt... fir! !rwrex.................. ... Q J D ___ ._------ - ---....._. ----- -- ------ __-_ - ------'---- .lA!¢.!.......................... ......... <�•.......... lM.... .�w.cn:..,......r.+. p..:rrir�"r'r........................... ............................ ....... J N sn.........................................weir..r ...... N = D aw-■4.war�4.. SR lamas/maaw uwa.. . -.- aae. rw.rm.■.N. M1111WI .sawae«rnwra.w• w.®wa ..wl.a4420 Tom"U■raew 7010116410004 - W L _/ rr�wrr..r4 ■w m PUt!ra Coal/MtIW iwr s00PU10.rriwr r z ar+wranrsr arrt „uamrr rwrw.rrrA.rw .Y+.rrws•r ........................an4laaMN................ a m to Z > o ■nw■aq t s.tnr..a ciw*nlln+.!.!rs............................_.................:as. o�as.�r. +e............ ti 4... P!!K?!!u! ................................................................................................................................... ... — --- rsrl■1 .au n n sa -- -wre - raaw!ai_4wwwrrr - - __.. -- ..r!4o,!P.+P!S!aAl.................................................._...........,.. .. ...1!•�!�.....f+41:�N............................................ ................... ..................... ....... ..P.r!�!Ala.!!r!al....:..............................._.....,........,.... . . ...:.. ...... rrrrr+.r.rrr.cYrar. M.i■.■►■..rP■MiW a1mNm.tae sm asm lose w d e �.w.....+rwra.�i�".o..u.■.n.....r....n J.......:........................................................... �( N 1 a alwr aa...ry ■r.rarrr.nr- .isrratiisairwiarw w, O W m -./4C U.— - a♦•g1Ji1LHw.r1.Y.� a1l.rrr■rr.nelrr ...-.. -. -. -- - ] r. Yyrb..inr 11 ..... ... .. ... LA N 0 CS c eta+arYlROaM _- 54II _.. of • .rrr.. rr rrrarrrra.w■w aUr.4UM.YAM .-,.a. >..... r.. - ^.M.„ U K rrN wr■rrrearrrrrr.r+.-a�.+rrrrrr.r+wr.rrrrrr..wrrw.r.rr ae : hhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhhh1 Tyll.l e.+Ir asi110..YalW4aM�i6.laM71aMM�ONt M..1M/Y4...1YA wtYrN. S. � I E f �'m �. CONTRACTOR: E ma E m w K 1415 Main Street Lot#154 DunedIn,FL 34698 r EC13007555 OS PV MODIA.E SPEC.SHE 02 ET *NERTER SPEC.SHEET 03 POWER OF M12ER SPEC.SHEET jared�greenmindedaoler cote — 828-333-0781 O suH:Ws u:Va W4 SC l:Ww U g b AI—GMS- LL MARTINEZ W J z 3=a DATA F �o F 22.APR.19 wac 9 I 8 I I 6 I 5 I 4 I 3 I 2 I 1 9 I 8 I 7 I 6 I 5 I 4 I 3 I 2 I 1 I CERTIFY THAT THE FRAMING OF THIS STRUCTURE WILL SAFELY ACCOMMODATE CALCULATED CONTRACTOR SHALL CHANGE/ADJUST THIS PLAN AS REQUIRED TO SATISFY FBC PV STRUCTURAL PLAN DESIGNED PER ASCE 7 WIND UPLIFT AND LATERAL FORCES AND EQUIPMENT DEAD LOADS.THIS IS ATTESTED TO BY MY (INCLUDING FBC 2017 SIGNATURE AND SEAL ON THIS DRAWING AT THE UPPER RIGHT. REFERENCED STANDARDS),AHJ,JOBSITE CONSTRAINTS,&OEM DOCUMENTATION FLORIDA BUILT $ - ENGINEER A YcS ALLEN GEZELMAN INSTALLATION NOTES I, 16502 HANNA RD. •THIS PAPER PLAN IS INTENDED TO PROVIDE THE ESSENTIAL INFORMATION NEEDED BY AHJ(AUTHORITY HAVING JURISDICTION AKA BUILDING KOH0011// ® LUTZ,FLORIDA 33549 DEPARTMENT)AND INSTALLERS. PH.8139091956 •THIS IS A SINGLE SHEET STRUCTURAL PLAN. AIIefI�GBZ/ID18I1PE oom •ELECTRICAL PLAN IS A SEPARATELY SEALED AND SIGNED DOCUMENT. AJ www.GezeImanPE.com n •SOLAR EQUIPMENT ADDS LESS THAN 4-PSF GRAVITY LOAD TO STRUCTURE. •SEE DRAWINGS&PHOTOS FOR MEANS&METHODS INFORMATION IN ADDITION TO THESE NOTES. I PE 59180 8 •THERE SHALL BE A PV MODULE TO RAIL MOUNTING CLAMP AT EVERY MODULE/RAIL CROSSING POINT WITH MINIMUM 4 CLAMPS PER MODULE. Flashfoot 2 ..._:_•ADJOINING MODULES ON SAME RAIL SHALL SHARE CLAMPS. UFOs _ •MODULES MAY BE LANDSCAPE OR PORTRAIT AT CONTRACTOR OPTION. S1) s) g(1{ten $ •ROOF IS ASSUMED TO BE COMPLIANT WITH FBC(FLORIDA BUILDING CODE)AS OF TIME OF CONSTRUCTION. •PV MOUNTING RAILS SHALL BE INSTALLED PERPENDICULAR TO ROOF FRAMING. •THERE SHALL BE A MINIMUM OF TWO RAILS UNDER EACH PV MODULE. W g4 o�S` •ROOF ATTACHMENT SPACING SHALL BE NOT GREATER THAN(NGT);6-FT CENTER-TO-CENTER(C-C)IN ROOF PRESSURE ZONE 1(PZ1);NGT 4-FT W C-C IN PZ2;NO INSTALLATION IN PZ3. B •RAILS SHALL NOT CANTILEVER BEYOND OUTSIDE OF END ROOF ATTACHMENT BY MORE THAN 1-FOOL •RAILS SHALL ATTACH TO ROOF THRU L-FEET BY STAINLESS STEEL(SS)LAGS NOT LESS THAN(NLT)5/16-INCH DIAMETER&NLT 3-INCHES IN %. _ ¢. THREAD LENGTH. •ROOF ATTACHMENTS SHALL BE FLASHED AS SHOWN HEREON. 01 AERIALZkt WA " 02 IRONRIDGE XR Ito RAIL&COMPONENTS.&TYPICAL SHINGLE FRAMING ATTACHMENT 6 tis/taa lm.roe � T ; •ALL FLASHINGS SHALL BE INSTALLED IN A GENEROUS BED OF FLORIDA PRODUCT CONTROL APPROVED(PCA)POLYURETHANE ROOF SEALANT. `� tTTre,�cscm4•attar- a € •CONTRACTOR SHALL PROVIDE AHJ WITH ADDITIONAL INFORMATION AS REQUIRED. "• ` V 140 108.4-MPH,RISK 11,EXPOSURE B.PZ2-WIDTH 4-FT;H"VG< 15 FT.& •ENGINEER OF RECORD FOR PREFERS EMAIL COMMUNICATION:alien@gezelman e.com """"P""�°°"'®°" 'H°°`*•w°®nn1�••a'oar,w•a� i utT NASD s (EOR) P � ,.ww�eme� c �sarnas ® oe rov r ; 7°< ROOF SLOPE< 27'.WIND UPLIFT: PZZ 16.1 PSF,PZ2-28.7 PSF,PZ3 41.9 PSF. wm.�wnauuwas.sr Tnx naonro.sr nor PV MODULE--� IRONRIDGE UNIVERSAL FASTENING OBJECT E PV MODULE FRAME4 . W 4 AC DISCELEC.SVC. 26 /-XR.100 IRONRIDGE UNVERSAL 1" ENTRANCE, ' >3-FT.NFPA4 FIRE ROOFLIN FASTENING OBJECT C C (D7 a OEN RETEER ACCESS CLEARANCE 1'-0',TYP. FRAMING O___ Lj p. r----- --------- ----------- T�---P22-- -8`� RASHRN7T2 46',TYP. IRONRIDGESTS R W O TYP. _ I - IRONRIDGE RAIL N O -t O Z3 ( ®MWDIAE.RAIL.ROOF ATTACHMENT CROSS SECTION DETA4MID CLAMP FROM ��DETAIL END CLAMP FRONT O 0 III I O 3 i sva 1rs s 1,5 1n u I I ao N O — 1 11/16 0 L O r 0 cM / 0 EXISTING ASPHALT I ( 1.5-FT.NFPA-1 FIRE N SHINGLE ROOF I ACCESS CLEARANCE MINIMUM Q LL I ON 244NCH C-C K THREAD z (- N D RAFTERS/TRUSSES I I EMBEDMENT Q N I 9 N D z 1---- ------ -� ,� W = o I • Q 0 1 4, I 15/8 Z N } Zc 1 TYP. p c"5 EXISTING SPH ---- ALL WORK SHALL. l: Y�"1 ?. A «rwr. as Q No W co COLLECTORS I 1LI] I IRONRIDGE 54' 5/16 LA N 0 XR1DO RAIL,TYP. CODES FLORIDA t3 I ` O '� " ' _ - W NATIONAL ELE 1r 4, I ii IRON_EFLA OOAND THE CITY S ( ROOF ATTACHMENT,TYP. swt as ROOFLINE I SEE FIGURES 04,05&09. 04 ORDINANCES 23/16 v �y'w.7A �EAu ouo Gs 3Tsw W m I u ( 2 tl ua�- CONTRACTOR: BUILDING RE /1E W`J [)ATE 1'y i E W rc FOOTPRINT PZ2 F ( j 0i o I a I e, CITY () IRONRIDGE HYRHILL 1415 Mau,Sfreet Lot#154 F' -'-e 1 I I PZ2 TYP. I I RAIL SPLICE.TYP. PLANS .,jAA III f Dunedin,FL 34698 PLANS LL O I I I FWW Fpll0�111'<it2T1 /`�7'� EC13007555 I IRONRIDGE IRONRIDGE -333-0781 O 10.08 kW SYSTEM. I e T >3-FT.NFPA-1 FIRE 828lared�9reenmindedsdar.can y 32 60 CELL PV MODULES. I I I I ( ACCESS CLEARANCE �T 2 XR1000 RAIL p SEE.FIGURE 4 O a PZ2 WIDTH=0.4 x EAVE HEIGHT >�, I I I flI T I EXISTING ASPHALT o w: PZ2 WIDTH=0.4 x 10 FT=4 FT. i_L__1 SHINGLE ROOF - 8 53 ROOF ATTACHMENTS. IPzs I Pzz I Pz3 Pz3 Pz31 --- !—J I------ - - --- J a1w14BN;nwiwltr<�sm AI-GMS- z - k _4'.TYP. 3-FT.NFPA-1 FIRE D ■may ■ F MARTINEZ SNFATHING w8 ACCESS CLEARANCE PZ1:ROOF INTERIOR PZ3:OUTSIDE CORNERS F w W PZ2:ROOF PERIMETER L&W= PZ2 5/16"CRS.LAG w/ EXISTING STRUCTURAL 25_o (MIN.3'&LEAST OF 40%EAVE 3"THREAD EMBEDMENT FRAMING F o $. HEIGHT OR 10%BUILDING LJW. a=PZ2 WIDTH.,h=EAVE HEIGHT. IN BLOCKING,JOIST, w a t 07 PL""vIAw OR TRUSS I ASCE 7-18 COMPONENTS GADDING ADDG WIND PRESSURE ZONES. ® OOT 2 SHINGLE ROOF ATTACHMENT 22.AP R.19 RAIL ND sauce ars 9 I 8 I 7 I 6 I 5 I 4 I 3 i 2 I 1 9 I 8 I 7 I 6 I 5 i 4 I 3 H 2 I 1 PV SYSTEM ELECTRICAL DESIGN SYSTEM:32-HANWHA QPEAK DUO-G5 31M+ NATIONAL ELECTRICAL j � THIS PLAN IS CERTIFIED BVENGiNEEROFRECORDASCODECOl4PLUWT6APPROVED 32-SE.P320 OPTIMIZER+ CONTRACTOR SHALL COMPLY WITH SOLAR PROVISIONS 2015 NFPA 1.http://gezelmanpe.com/Generic/NFPAi.pdfIJ coDE,NEC(2O14J $$ FOR FLORIDA USE IN ACCORDANCE WITH He 1021 ON ELECTRICAL PLANS. /www.RorklabuOdin 17-6edidon 611121-Constructlon. 1-SE7600H-US I ENGINEER e°8 ALLEN GEZELMAN 16502 HA NNA RD. I A A 5 1.ALL ASPECTS OF THE ELECTRICAL WORK REQUIRED TO COMPLETE THE MODULE SPECIFICATIOINS INVERTER SPEaFIcATION5 OpuMIzER SPECIFICATIONS LUTZ,FLORIDA 33549 PROJECT REPRESENTED IN THIS DOCUMENT SHALL COMPLY WITH THE Module Make HANWHA I Inverter Make Solardedge Optimizer Make SolarEdge PH 819 9091956 MANUFACTURER'S RECOMMENDATIONS/SPECIFICATIONS AND ALL CODES, Module Model (WEAK DUO-GS 315W Inverter Model SE-760ODH-US Optimizer Model P3zo MARKING AND LABELING REQUIREMENTS: STATUTES,AND STANDARDS ADOPTED BY THE STATE AND THE LOCAL Pnrax(src) 315 W Max AC Power Output 7.6 kW Rated Input DC Power 320 W ARenCGezelmanPE.corn Markings shall comply with 690.31(E)(3)and(4),and shall be wwa GazelmanPE.com AUTHORITY HAVING JURISDICTION. Voc(STC) 39.87 V Max.Input Voltage 480 v Absolute Maximum Input Voltage 48 Vdc placed on ALL interior and exterior DC conduit,raceways, i2.ALL COMPONENTS MUST BE GROUNDED PER NEC 690.43. Vmpp(sTC1 32.98 V Nom.DC Voltage @240V 400 V Maximum Short Circuit Current(Ix) 11 enclosures,and cable assemblies at least every 10 feet;at PE 59180 3.ALL EQUIPMENT SHALL BE LISTED PER NEC 690.4(D). Ix(5Tw) 10.04 A Nom.AC Voltage 240 V MPPT Operating Range 848 vac turns and above/below penetrations and all junction boxes. 4.THE INFORMATION PROVIDED IN THESE DOCUMENTS IS NOT Impp(STC) 9.55 A Max.Continuous Output Current 32 A Maximum DC Input Current 13.75 Adc EXHAUSTIVE.IT REMAINS THE CONTRACTORS RESPONSIBILITY TO NOR 45±3 c Max.DC Current 20 A Maximum output Voltage 60 Vdc WAR G u g ACHIEVE THE PROPOSED INSTALLATION,IN FULL EXERCISE OF AND rc Ix 0.04 16/IL Ma durum DC Power(SIC) 11800 W Maximum Output Current 15 Adc WARNING mLHAzuRD P1 !• �+ �O COMPLIANCE WITH THE ITEMS IDENTIFIED IN NOTE 1. TCVOC o.za %/It ctCESRciency 99 % etEcrlxxSHOCKRzARD. DO NOT T TERMINAL System Current=#Strings X Module Current(Ix or Imp) FAcrmurn°'u�T rs eox°`t�.Noruwlr TERwwALS LINE AND - 5.PER NEC690.17,PROVIDE A WARNING SIGN AT ALL LOCATIONS TcPmpp .037 sL/X SystemVowg�RlcadStringVolatile 1A1pED °"a sroEsttAy Rc®INnIE i MAY BEUrKIIOUND®MDE NERD®. ' WHERE TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED OperadngTemp. -40to85 c nrray#1 ysys v string#1 Imp 12..60 A PosmoN. IN THE OPEN POSITION.SIGN SHALL READ"WARNING-ELECTRIC SHOCK String#1 vsys 400 v String#2 Imp 12.60 A LABEL PLACEMENT LABELPLAcamwr I HAZARD-DO NOT TOUCH TERMINALS-TERMINALS ON BOTH LINE AND stnng#2 Vsn 400 v JUHcnoN Box&yrvmmt AC DISCONNECT.NEAR BREAKER. _ > — B G V LOAD SIDES MAY BE ENERGIZED IN OPEN POSITION"OR EQUIVALENT. (FRONT OF PANEL I DEAD FROM) ernx6rwn vaswax®dLP 6.PER NEC705.10,PROVIDE A PERMANENT PLAQUE OR DIRECTORY OPTIONS aroWtse—ty(DC)=linnX1 6 araRAmpacitl lImax c°utputc"rrent A air rtss 2 SHOWING ALL ELECTRIC POWER SOURCES ON THE PREMISES AT SERVICE string#1 Max 19.7 A Inverter Irnlax 140.0 A WARNING WARNING ktlO�,xea�xmmAei®ri C 5 Number of Modules 32 String#2 max 19.7 A oe Nx_:80vAD. FBPE emxWre sHxor W6cox ENTRANCE. Number�svings 2 PHorovarArcautsw6JiJEer DUAL POWER SOURCES v,,.,,,:NeoY 7.INTERCONNECTION METHOD SHALL COMPLY WITH NEC705.12. String#1 16 Arrwwxts=#MoaaesxMoardeSlCWatrsx.9sXhwenter RATEDMPP1CURRENT 12.60 A g OTOVOLTMC V...4 00V 8.PV METER MAY OR MAY NOT BE REQUIRED BY THE AHJ AND/OR UTILITY String#2 16 Eflicitlncy RATED MPP2 CURRENT 12.60 UA i'^12eA 8... FOR INTERCONNECTION. SIC DC POWER(KW) 10.08 Array#1 9.48 kW RATED MPP VOLTAGE 400.0 LABEL PLACEMENT: LABEL PLACEMENT: DC/AC SRJNG1326 MA%.SYSTEM VOLTAGE 480.0 9.CONDUCTOR SIZING OF THIS DESIGN IS BASED ON RACEWAYS PHOTOVOLTAK"C OUTPUT MAN PANEL NEAR METER JUNCTION BOX .LOCATED OUTSIDE ATTICS OR NOT EXPOSED TO DIRECT NOMINAL AC VOLTAGE zooVMAX.INPUT CURRENT 20.00SUNLIGHT.Exception: Where two different ampacities apply to adjacent portions Ac OtIIPUTCURRENr 32 A MAX sc INPUT CURRENT 65.00 WARN I N ELECTRICAL SHOCKHATARGD. DC SHOCK HAZARD. � WARN I N G of a circuit,the higher ampacity shall be pe►mftted to be used beyond the point of VOLTAGE DROP uuxJurwNs Nd'2"L"R=U1aool NEC 2011 215.2(Ax4) INo txERSERVICArtE PARTS NsnoE. V,,,":Neo v transition,a distance equal to 3.0 m(10 ft)or 10 percent of the circuit length figured FACT ALmaRIZED SERVICER FOR at the higher ampacity,whichever is less.NEC 310.15(BX2) wIRE RUN w blip R L(ft) 1.27 0.%32 WIRE Ass STANCE _:�" PV STRING TO(UNCTION BOX(TYP.Of 2) 4000 0 12.6 1.26 40 0.32 #10I L..,:+2.s A E 10.UTILITY CONNECTION SHALL BE MADE BY LINE-SIDE TAP PER NEC JUNCTION BOX TO INVERTER(TYP.OF 2) 400 12.6 1.26 20 0.64 0.16 #10 Q u ARTICLE 690.64(BX2)LOCATED WITHIN CODE COMPLIANT ENCLOSURE. ERTERN+ECr JLNNCT DN nrox AJNCT ON BOX W INVERTER TO PV AC DISCONNECT 240 32.0 0.783 15 0.75 031 #8 INVERTER C C F-- ui 11.ALL CONDUCTORS AND RACEWAYS SHALL BE SUPPORTED ON O PV AC DISCONNECT TO AC LOAD CENTER 240 32.0 0.783 10 0.50 0.21 n8 P\/AC O Z INTERVALS AND BY METHODS REQUIRED BY THE NEC. PHOVOLTAIC POWER r v v < O CD m 12.CONTRACTOR SHALL PROVIDE ADDITIONAL INFORMATION IF REQUIRED SOURCE DISCONNECT w BY AHJ. 1 13.FOR PREFERS EMAIL COMMUNICATIONS alien OQ9@ZeIR18f1pe.COfi1 sPEGFiCATIONS.CALCULA,IONS.&tABELS EWAY&JUNCTION °'^ W O 02 srlNEfl/A RACEWAY&ANNCTION BOX yy:3zA O O �j Vr PV Modules @ 315 Watts STC LABEL ptACELIEHr: ' CJ 01 ELECTRICAL NOTES 32 Modules per Inverter 10080 watts SIC AC DISCONNECT SCIeLNIA PV Wire in free air or r Z �i 3/4"NMLT conduit O 0 ?� 10 AWG Cu wire each U) V- 6 Bare Copperg EGC 16 15 0 0 0 3 2 1 STRING#1 M 9i SoMrEdge SE7600H US U Inverter 16 MODULES 99%CEC Efficiency @ 240 Vac V LJL CV 7600 Wee Continuous EGC&GEC bond + _ + + — + + — a CD Maximum Output Current 32 Aims — at racking system, _ — — a Cl, (V Maximum Input Current 20 Ada. _ J I Gro nd fault protection provided o 0 o W D Q TO GRID see note#2 D — SolerEdge ACJDC Safety Swit h ot 440 Vac,50 amps continuous �/ ~ } IL 9 600 Vdc,36.5 amps Continuous (4)#10 THWN-2 conductors& N a V Une-side Tap Opens alt ungrounded Coductors (1)#10 THWN-2 EGC in 3/4" Q CJ W tp N L2 T.1 e.g.Iisco Kup-L-Tap per NEC article 69.0.35 FMC or EMT,for exterior L0 N d IPC or equal O O — O O a lication 1"PVC or LNFC. STRING#2 _ pp 16 15 0 0 0 3 2 1 4a'w See note#10 RE:Note#09 16 MODULES a Junction Box DISC(N4NECT w See note#10 40A,240V,2-POLE _ — 40A T.2 E o AC Load Center "e 200 A service G 14tD in.FL t 54 U rr 200 A bulbar EC13007555 L� NEUTRAL D I SolarEdge Power.Optimizer P320 jared@greenmtndedsolarcorn a—i T TO O GROUND Rated DC Input Power-320 watts 828-333-0781 Maximum Input Voltage 48 o8 (3)#8THWN-2 conductors 1 810 THWN-2 EGC JUNCTION BOX MPPT Range-81048 Vdc 3 b ( ) PV Wire in free air or 3/4" Maximum Input Current-13.75 Adc O w (3)#8 THWN-2 conductors in In 3/4"FMC or EMT,for exterior NEMA 3R NMLT conduit,10 AWG Cu Maximum Output Current-15 Adc 3/4"FMC or EMT or 1"PVC or application 1"PVC or LNFC. PV WIRE TO THWN-2 wire each.Positive,Negative String Limitations-8 to 25 Optimizers, W O} 01,0 LNFC for outdoor use, RE:Note#09 TRANSITION 5700 watts STC per string maximum O M! o RE:Note#09 AI—GMS— MARTINEZ Lu z g -11 (1)#1oTHWN-zEGc I AWE G Wo ELECTRICAL F F c7 0 x #6 GEC to existing ZIZft I ground electrode — ELECTRICAL DwoRAM 22.APR.19 Ground 03 scuzsrns 9 I 8 7 I 6 5 I 4 I 3 I 2 I 1