Loading...
HomeMy WebLinkAbout19-21350 CITY OF ZEPHYRHILLS ` 5335-8TH STREET (813)780-0020 21350 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION W' Permit#:21350 Issued: 6/06/2019 Address: 6987 SILVERADO RANCH BLVD Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 347,525.25 Total Fees: 15,505.19 Subdivision: SILVERADO Amount Paid: 15,505.19 Date Paid: 6/06/2019 Parcel Number: 05-26-21-0100-00600-0550 CONTRACTOR INFORMATION OWNER INFORMATION .: Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE, FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,085 SQ FT APPLICATION FEES . ' PLUMBING FEE 267.00 ELECTRICAL FEE 400.50 MECHANICAL FEE 186.90 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,890.60 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 0 Inspections ftecjWked FOOTER 2ND ROUGH PLUMB MISCO IN ULATION CEILING FOOTER BOND DUCTS INSULATED SEwfflR MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or, first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental, entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance' with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. i i CONTWACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name 'b 4'�—VN Control#* County Parcel No. b6-2,6-U-0tqa-61Qbx--6,99-l2 SubDIv: Address/Location 41W-A &V-P ClassificationlType of Us@ 31-- 40 TRANSPORTATION IMPACT FEE Rate* Sq.FtUnIt: Exempt n Yes 0 No How Determined Impact Fee Amount $. 31(0 Vy Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 2 (057) Mobile Home (058) Other Residential (123) Collection Fee Exempt Lj Yes 0 No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ Exempt 0Yes FINo How Determined LIBRARY FEE Land Account Land Credit Land Total Facility.Account Facility Credit Facility Total Exempt 0 Yes F1 No How Determined Total Amounq�L RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply recelpt of�'a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for soma. DATE RECEIVED BY RECEIPT NO. DATE BY i D.R. Horton-6987 Silverado Ranch Blvd:3,085 sgft Column SQ. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 347,525.25 FEE SHEET $ 1,780.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,890.60 ELECTRICAL: $ 400.50 PLUMBING: $ 267.00 MECHANICAL: $ 186.90 SUB-TOTAL $ 2,745.00 TOTAL $ 2,745.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,298.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 15,505.19 F4aniun City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: e— —j� Date Received: Site: L� /8 CS) lG� '0AV-kg11jn Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ 6-el ilG This comment sheet shal'be kept with the permit and/or plans. JUN Q 6 2019 h Kalvin '' z —Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Fax-813-780-0021 . . City of Zephyl'h'ills Permit Application . Building Department Date Received I?` Phone Contact for Permitting - -[T �i Owner's Name - c j-, ¢= Owner Phone Number l Owner's Address Owner Phone Number Fee Simple Titleholder.Name -r i '� �i Owner Phone Number i Fee Simple Titleholder Address JOB ADDRESS 19y \ r- LOT# 'Er SUBDIVISION L=''"�r PARCEL ID# 5 r - (OBTAINED FROM PRO ERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR ADD/ALT SIGN F DEMOLISH ; INSTALL REPAIR PROPOSED USE F-9f SFR COMM OTHER TYPE OF CONSTRUCTION _ �� 'BLOCK FRAME STEEL p DESCRIPTION OF WORK BUILDING SIZE �! 7 SQ FOOTAGE 3085 (� HEIGHT r-rl a a �P—t'-e'^t"YTP"TF—k-4"�16T"r"a�'T�AT6'r—r"r'PT BUILDING $ Coo VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $. ow AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING =MECHANICAL $ (4 VALUATION OF MECHANICAL INSTALLATION ' t =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS �• FLOOD ZONE AREA [ YES NO -4--II-9--i-i-6-F-g-i'-5--1-C--i-C--i-i-C-i-8-�6-�1-i- -s`-9-E--Ir-:-4 fir,'- - 9, '-r.-R-i+-i-i-➢--6-1�' BUILDER' J� COMPANY F.. -�rJ.''A-c-""� �1r C SIGNATURE REGISTERED Y/ N FEE CURRER Y/N Address %cUl 1 f l e-<,o.-r) License# - cam' 0 6 ..F-LECTRiCIAN �'� COMPANY SIGNATURE REGISTERED I Y/ N FEE CURRER Y/N Address ds'?- '1����= P �rC° , License# r c" 4c r PLUMBER COMPANY f p ) a+ ~ .SIGNATURE REGISTERED Y/ N FEE CURRER YY/�N/ Address �£ rr. mids��. .t License# MECHANICAL' a r COMPANY ,, ae, r ° x SIGNATURE f �" " �' `--REGISTERED I Yq,N FEE CURRER Y/N Address . License# OTHER � f j COMPANY SIGNATURE ' REGISTERED Y/ N FEE CURRER Y/N ' Address License# 11I611iNi1' litiilii = iiiiittitiitltllli11II1iiEitllllilIIlQl61. 7i90fIp98i991 RESIDENTIAL Attach(2)Plat Piar:a; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten (10)vxirking days after submittal date. Required onsite,Construction Plans,Stormwater Plans wi Slit,Fence installed, Sanitary Facilities&1 dumpster;Site Wark'Permit for subdivisions/large projects COMMERCIAL Attach (2) complev. sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new-construction. Minimum ten (10)\ Irking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit Fence installed, Sanitary Facilities c..1 dumpster.Site Work.Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. i ""*PROPERTY•SI.!,IVEY required for all NEW construction. .,.a..�..b-i-.8-1-t-7-.6..-0-a..l--i-q-Y-f..-0..•',�-1-�-1-..d-i-R-lS-4-1F.-i..II-H--'�i-.6--i--i.-b..,&-i.-6--�-I!-6-6-i-i..5..8-6--d--�-4..9--@-1-E1...8�.D-i...&.i-�9-6.-^..8.-0..E-. Directions: Fill out application completely. Owner�Contractor sign back of 0plication,notarized If over$2500,a Notice of Comw.vricement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Pownr of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy Of contract required) 75p b: a, .,.><•„r,, ,.-. ,...,,-: Reroofs•if shingles • Sewers t,ervice Upgrades A/C Fences(Plot/Survey/Footage) ." Driveways-Not over Counter if on public roadways-needs ROW _ . . ` . . . NOTICE K]FDEED RESTRICTIONS: The undersigned understands that this permit may bo subject to "deed^ ne", ' which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND K_001 RACTOR RESPONSIBILITIES: If the owner has hired a contractor or oontranbonotoundertakemmrk. theymaybanaquiredtobe |icansedinacnordannewithsta1eand |oms| regu\atione. If-the contractor is not-licensed as required by |aw, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended-contractorare requirements as to what licensing requir� enta may apply for the intended work, they are advised to contact the Pasco County' Building Inspection Division—Licensing Section at72T-847' ` 8008. Furthermore, if the owner has hired a contractor or oontramtons, he is advised to have the contractor(s) sign portions of the "controctor B\onK' of this application for which they l be responsible. If you,*as the owner sign as the y contractor, that mabe an indication that he is not properly licensed and is not entitled to parmitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation lmpa:ct Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing bui|dings, or expansion of existing buildings, as specified in Pasco County Ordinance number8Q'O7 and QO-O7. aoamended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. it in further understood that Transportation Impact Fees and Resource Recovery Fees,must be paid prior to receiving a "certificate ofoccupancy" or final power release. If the project does not involve a certificate of occupancy or final power re|eosa, the fees must be paid prior to permit issuance. Furthermore. if Pasco-County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter?13, Florida Statutes, omammeodecH: |f valuation of Work io $2.5OO.08or more, | omrdfv that |, the app|ioant, have been provided with � oopy of the "Florida Construction- Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAghcu|ture.and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"oxvner" prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating nonotruCdion. County and City codes; zoning regulations, and land development regulations. in the jurisdiction. | also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions | must take tobgincompliance. Such agencies include but are not limited to: ' Department of Environmental Prntection-(�ypreas Bayhaads. VVe�andAreas and Environmentally Sensitive Lands.VVa1eV�Jastewo1erTreo1nnent. ' ' ' Southwest Florida VVotnr Management Diotriot4Wo||o, Cypress. Bayheada, Wetland Areas. Altering VVetarnounaea. ' Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' Department of Health & Rehabilitative Services/Environmental Health Und-Na)\a' Wastewater Treatment, Septic Tanks. ' UG-Environmental Protection Agency'Aabe8hoaabatement. - Federal Aviation Authohty-F\unwsya. | understand that the following restrictions apply to the use offill: - Use of fill ia not allowed in Flood Zone'V" unless expressly permitted. ' If the fill material is to be used in Hood Zone "/Y'. it is understood that a drainage plan addressing a compensating volume" will be submitted at time of permitting which is prepared by a professional ang|oee'r licensed by the State ofFlorida. ' If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem vvaU construction, | certify that fill w ill be used only to fill the area within the stem wall. . ' M fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent . properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building per?nit issued under the attached permit application, for lots |aso than one (1) 8n[e which are elevated by fill, an engineered drainage plan is required. \f | amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction, | understand that a separate permit may be.required for electrical vvork, p|unnb)ng, aiOna, vvo\|a, pools, air nonditioning, gas,,or other inata||ed|ane not specifically included in the application. A pe[mit issued shall be conatfuod to be a license to proceed vvith-thevvork and not as authority to vio|o1e, oanoe|, a|ter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter r*quiringaoonaotionofernnnoinp|ans. nonstnurhonorvio|sUoneofmnyoodas. Every permit issued shall become invalid un|eas,the work authorized by such permit is commenced within six months of permit iaauanoa, or if work authorized by the pe[[O\t|ssVnpHOdedo[abandoned for 8 period,of six (S) months after the time the Work |acommenced. An extension may be requestad, in writing, from the Building Official for a period not to exceed ninety (QO) dayo' and will demonstrate � justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE [�F COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TQ OBTAIN FYNA0Cj0G, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA^un*/ (Fo ``' u) _C\NNER OR AGENT CONTRACTO*R Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed). _before—e this ' is/are personally known tomi�or has/have,produced Who isiam personallyxn to me or has/have identification. - Notary Public Notary 4is/ar,e Public ` Commission No. Name of Notary typed,printed or stampedState of Florida-Notary Public ;k My Commission Expires NI ' 05-26-21-0100-00600-0550 1 Pasco County Property Appraiser Page 1 of 1 Parcel ID 05-26-21-0100-00600-0550 (Card: 1 of 1) Classification 00000-Vacant Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $25,046 TEMPLE TERRACE, FL 33637-0935 Building $0 Extra Features $0 Physical Address 6987 SILVERADO RANCH BOULEVARD, Just Value $25,046 ZEPHYRHILLS, FL 33541 Assessed (Non-School Amendment 1) $25,046 Legal Description (First 200 characters) Non-School Taxable Value $25,046 See Plat for this School District Taxable Value $25,046 Subdivision SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A AND 11B PB 77 PG 079 BLOCK 6 LOT 55 OR 9535 PG 0546 Jurisdiction CITY OF ZEPHYRHILLS Land Detail (Card: 1 of 1) Line'Use Code Description Zoning Units IType jPrice Condition Value 1 0100V LP1-1 SFR_ MPUD 6,000.00 SF $4.00 1.00 _ $24,000 2 0100V LP1-2 SFR ^� MPUD 2,615.00 1 SF 1 $0.40 1.00 $1,046 Additional Land Information Acres_ Tax Area FEMA Code Res Code Com Code _ Condo Code 0.20 30SI -- SLVR SLVR SLVR Building Information (Card: 1 of 1) Unimproved Parcel _ Extra Features (Card: 1 of 1) Line _ Code ascription ,Year Units Value No Extra Features Sales History Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type DOR Code Condition jAmount 05/201S 9907 / 2781 Warranty Deed _ 05 Vacant I$336,300 05/2017 9535 / 0546 Certificate of Title 05 Vacant I $0 11/2016� 9462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant $0 04/2016 9364 / 0688 Mineral Rights or Royalty Transfer 05 Vacant $0 03/2016 9356 / 1231 Mineral Rights or Royalty Transfer 05 Vacant $0 09/2011 f 8606 / 3376 _ Warranty Deed 05 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126050100006000550 6/6/2019 9. V d k o. Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of-8" above the road elevation and d an engineered site plan. 2. Lots shall be graded to cor' ly with R401.3 of the F.B.C:. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit: All 4 sides of driveway thru the sidewalk shall have expansion material. -6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.requirements shall be.niet: 9. No electric,plumbing;mechanical,or framing shall be covered without an inspection and . approval first. 10: All Garages shall comply with section R3016 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.:4 of the F.B.0 12. Water heaters-shall comply with section P607.3 of the F.B.C: 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.1- 14: Return air in all bedrooms. F.B.C. M1620:4 1.5. Smoke detectors are to be installed in accordance with R313.1 of.the F.B.C. 16.All glazing requirements are to be iri accordance with R308.4 of the F.B.-C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum,board" shall not be used as a backer in showers or tubs. R702A.2 F.B.C. 19. Combination-type AM breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 2-1. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. i 23. Tamper- Resistant.Receptacles in accordance with 406.11 of the 2016 N:E.0 24. In accordance with the Land Development Code,lots.shall be sodded before final at least 10 feet around the structure. 25. R403.5.3Hot Water'pipe insulation.' Insulation for hot water.•pipe with-a minimum thermal resistance (R-value) of R-3.shall.be applied to the following: Piping 31. inch (1.9.1 mm) and larger in nominal diameter. Piping serving more than one dwelling unit. Piping located outside the conditioned space.. Piping from the.water-heaterto a distribution manifold.- Piping.located under,a floor slab: Buried in piping.. Supply and return piping in recirculation systems other than demand recirculation systems, 25.Blower door test shall be provided before C.O: 26.A copy of the energy:eacls'shall be:with at all times. 27. Copt/of fnal."insulation report shaft be provided with permit before frnaL 28. No fence,pool or screen enclosure :is issued with:this permit F.F.E..-Finished Floor Elevation F.B.C- Florida Building Code 6t'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) i j PLOT PLAN DESCRIPTION:(AS FURNISHED) PT LOT 55, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASES 7, 9B, 11A & 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve III Length Radius Delta Chord Bearing Chord I I � Cl 50.79' 2140.00' 1z1'35• SO7z9.17•E 50.78' LOT 56 C2 506.34' 21DO.00' 13'5rO9' SO42W33•E 507.10' I BLOCK 6 C3 351.17' 2100.00' 9'34'52' S0211'54•E 350.76' I = 04 157.17' 21DO.00 417'17• S09-07.59•E 157.13• I I `r�9�,,U�� « RC TEARING) I 1" = 30' PREPARED FOR: i HIC SCALE S87'24'28"E 167.97' ?�`�' N67z4'28•W 1 to 0 15 30 D-RR'/14DiR/ N-� > 0 I 105.2' � � C 5'DQtAE u -- 40_56' — OIo, � N -- tbtJf'CSL2=S y?LLESi' 8 0 I I 40.T — --- CZ a I Fa BUILDING SETBACKS _is-- w Z. W a cV I i m W O \ v }t.' :m:`.. .o;.:, :.t.:: r�-REDO FRONT: 22' �m �m M �� n o 'wo a g9 �$ woc)�70 REAR: 15' I m i- o K8 20' �;:..r-1;:ai:i% ,:,, '.. ON LOT CALCULATIONS SIDE: 5 71 (50' LOTS) SSI 7.5' (55' & 60' WIDTH LOTS) xo o a ;`� 3 I MI} � ` po• _': I I y n LOT = 8,615 SQ. FT. ag m o .0 1 SIDE STREET: 15' ^O o n < = LIVING AREA = 1,104 SQ. FT. x I O o;.; ' I GARAGE = 437 SQ. FT. m 8.0 NOTES: Z I a=�: 4267' 1 "t ENTRY = 43 SQ. FT. 1. ELEVATIONS SHOWN ARE PER LOT GRADING 1 3' 7, 1 LANAI = 0 SO. FT. PLANS PROVIDED BY THE CLIENT. I 5'D&AE '^ - 3 PATIO = 80 SQ. FT. 2. ELEVATIONS ARE BASED ON NAVD 1988 °'A �� �.aa N87*24'28"WDATUM. N A/C DRIVEWAY 527 SQ. FT. 3. FOR ALL LOTS WHERE SIDE-YARD I I s m d (NON-RADIAL) 176.85' I WALKWAY = 30 SQ. FT. SETBACKS ARE LESS THAN 7.50 FEET, A I 1�ro IMPERVIOUS = 26% MINIMUN 5.00 FOOT WIDE DRAINAGE AND I I .ry 1 = 2263 SQ. FT. ACCESS EASEMENT IS REQUIRED PER PASCO I SOD = 6.352 SO. FT. COUNTY LAND DEVELOPMENT CODE. OFF LOT CALCULATIONS LOT 54 1 RIGHT OF WAY = 1233 SO. FT. THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES BLOCK 6 DRIVE APRON = 203 SQ. FT. ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF I PUBLIC S/W = 242 SO. FT. THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND SOD - 788 SO. FT. OPTION UST FOR CONSTRUCTION. ALL BUILDING SET BACK TOTALS LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT AREA = 9.848 SQ. FT. AND IS FOR INFORMATIONAL PURPOSES ONLY. PI DRIVEWAY = 760 SO. FT. THIS IS NOT A SURVEY SIDEWALK = 272 SO. FT. THIS IS A PLOT PLAN ONLY SOD = 7.140 SO. FT. FLOOD NOTE: LEGEND: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M.MAP NO.12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE HAVE SEPTEMBER 26. 2014,AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE•X•,AREAS DETERMINED TO BE OUTSIDE THE —•—•— BUILDING SETBACK LINE PI POINT OF INTERSECTION OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO PC POINT OF CURVATURE MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE CONTACT THE ——— CENTERUNE PT POINT OF TANGENCY LOCAL F.EM.A.AGENT FOR VERIFICATION. ———— RIGHT OF WAY LINE RP RADIUS POINT 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN PRC POINT OF REVERSE CURVATURE LOCATED EXCEPT AS SHOWN. BEARING BASIS: PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE BEARINGS SHOWN HEREON ARE BASED ON THE NORTHERLY LINE OF CS CON PROPOSED A5hft 3. NOT VALID WITHOUT THE AUTHENTIC LOT 55. BLOCK 6 BEING S87z4'28•E, PER PLAT. ED DRAINAGE FLOW CS �CRETE SLAB ELECTRONIC SIGNATURE AND THE AUTHENTIC PLAT ELECTRONIC SEAL OF A FLORIDA LICENSED ' CONCRETE (C) CALCULATED NA E C A IC FR I I SURVEYOR AND MAPPER. (FIELD DATE:) REVISED: PB PLAT BOOK A/C AIR CONDITIONER P(S PAGES S U FR V E Y I N G oleman SCALE: 1'-30 FEET S/W SIDEWALK SO.FT. SOUARE FEET �'e•A+: oNDig'c Ii 11m Bo emigned yan o Jim BAmerkan F.EM.A. FEDERAL EMERGENCY MANAGEMENT AGENCY K3cM A P P I N G I N C. " APPROVED BY: `B F.I.R.M. FLOOD INSURANCE RATE MAP . SurveyingleMapping,ou, NAVD NORTH AMERICAN VERTICAL DATUM CERTIFICATION OF AUTHORIZATION NUMBER LB/6393 emac:-Us lemanpasmcorporatec _ 1ODB20 LOT 55, NGVD NATIONAL GEODETIC VERTICAL DATUM „".r�•,°.".�` 3191 MAGUIRE BOULEVARD, SUITE 200 a .•om,c=US. FOR JOB NO. BLOC(6 D&UE DRAINAGE&UTILITY EASEMENT ORLANDO, FLORIDA 32803 Date:2o19.at.2476:06:44-os'0o' THE POE PRIVATE DRAINAGE EASEMENT FIRM DS8 RDRAWN BY & E DRAINAGE Af S EASEMENT WWW.AMERICANSURVEYINGANDMAPPING.COMDA DAUC ETIEA J 426-7979 AMES W. BOLEMAN PSM# 6485 DATE PLOT PLAN 1 23 19 RMB INSTR#2019084360 OR BK 9908 PG678 Page I of I 05/17/2019 03:09 PM Rcpt:2055796 Rec:10.00 DS:0.00 IT:0.00 PauCa S. O'WeX PfLD., Pasco County CCerk&Comptroller Permit No. Parcel ID No D Q(0 uco - Q2!QM:- NOTICE OF COMMENCEMENT state of Florida County of PaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain reisi property,and In accordance with Chapter 713,Florida Statutes, the following Information is provided In this Notice of Commencement n' . 1 Description of Property: Parcel Identificaflon No. s 5 GLM LA Si k verado Prosie CA e) - - S 't\Vk CoAn RajKk 61 vA -Zap kwchil Is. R-3 35R Street Address:*Cog?01 2. General Description of improvement Now Single Family Residence 3. Owner Information or,Lessee Information If the Lessee contracted for the improvement: D.R. Horton. Inc Name 19BQ2 TtPdecam Drive Tampa 33637- Address city state Interest In Property: Fee Simple Name of Fee Simple Titleholder. Of dffferent from Owner listed above) Address city:. state 4. Contractor. D.R. Holton. Inc Name 12602 Telecom Drive Tampa 33537 FL Address city state Contractors Telephone No.: 5. surety: N/A Name Address city State Amount ofBond: N/A Telephone No.: 6. Lender -N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: --David Guds Name 12602 Telecom Nye Tampa 33637 FL Address City State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates - N/A of toreceive a copy of the Lienor's Notice as provided in Section 713.13(2)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration data may not be before the completion of construction and final payment to the contractor,but wilt.be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notic commencement and that the fact stated therein we true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signature of Owner or Lessee,or Owner's or Lessee's Authorized Officer/Director/Partner/Manager Assistant Secretarv/D.R. Horton, Inc Signatory's We/Office The foregoing instrument was acknowledged before me this ` day of r024 20'%Q kby as Assistants ecrefa (type Of authority,e.g.,officer,trustee,attorney in fact)for D.R. Horton. lnr,, name Of party on behalf of whom ran t was executed). Personally Known Produced Identification 0 Notary Signature "C-1 CZ, Type of Identification Produced Name(Print) EDANA ANNE NAGHTIN of FloridaOF' Notary Public-State of Flol O108, o .,.F Commission#GG 0 Jul 2.2020 My Comm,Expires ul 12.2020 tvpdatalbesinoUcecommencement_poDS3048 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev J Builder Name: PRJA Express Homes Street: v et 0J 241a'1 `g IUC,� n Permit Office: C Xb 2epky/-�j�'(�S City,State,Zip: Zephyrhills,FL, 3 I y Permit Number: 24 3J-0 (_ Owner: Jurisdiction: (1(060 Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2389.10 ft2 b.Frame-Wood,Adjacent R=11.0 314.89 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(252.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl, U=0.34 212.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.208 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features EF:0.950 b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.097 f1�7�7ASS Total Proposed Modified Loads: 86.41 P Total Baseline Loads: 86.20 I hereby certify that the plans and specifications covered by Review of the plans and 'S%E S�^,�r; this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance e with the Florida Energy Code. PREPARED BY: Before construction is completed w DATE: 1-23-M this building will be inspected for - a . compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code OWNER/AGENT: BUILDING OFFICIAL: DATE: i DATE: r - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.060 Qn for whole house. 1/23/2019 12:58 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev J Builder Name: DRH Express Homes Street: �q`72 5111"ad� 044'161 46-tud Permit Office: 10 City,State,Zip: Zephyrhills,FL, �� �✓ Permit Number: Owner: �C Jurisdiction: Design Location: FL,Tampa `-�J County: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2704.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2389.10 ft2 b.Frame-Wood,Adjacent R=11.0 314.89 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (1541.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11.Duct c. R= ft2 s R ft2 7. Windows(252.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 212.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.208 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.097 Total Proposed Modified Loads: 86.41 PASS Total Baseline Loads: 86.20 I hereby certify that the plans and specifications covered by Review of the plans and 114E S�� this calculation are in compliance with the Florida Energy specifications covered by this -"v l T;` 0, Code. calculation indicates compliance ';, with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 1-23-1`1 this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. , with the Florida Energy Code � 0 WTI OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: j - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, ! tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.060 Qn for whole house. 1/23/2019 12:58 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT s Title: Hayden 2605 Elev J Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 2605 Lot# 55/6 Owner Name: Total Stories: 2 Block/Subdivision: Silverado #of Units: 1 Worst Case: No PlatBook: Phase 9 Builder Name: DRH Express Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face E CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 2605 22630.4 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 13058.7 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ft2 ---- 0.2 0 0.8 2 Raised Floor 2nd Floor ---- ---- 437 ft2 19 0.5 0 0.5 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1669 ft2 0 ft2 Dark 0.92 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC i 1 Full attic Vented 300 1541 ft2 Y N I 1/23/2019 12:58 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 I FORM•11405-2017 INPUT SUMMARY CHECKLIST REPORT CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below TO Well Type 1 N=>E Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 2 W=>N Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 3 S=>W Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0 4 E=>S Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0 5 N=>E Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 6 W=>N Garage Frame-Wood Main 11 16 0 8 8 138.7 ft2 0.23 0.01 0 7 N=>E Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 8 W=>N Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 9 S=>W Exterior Concrete Block-Int Insul2nd Floor 4.1 39 8 8 8 343.8 ft2 0 0.6 0 10 E=>S Exterior Concrete Block-Int Insul2nd Floor 4.1 40 8 8 8 352.4 ft2 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated Main None .4 3 6 8 20 ft2 2 N=>E Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 90 degrees). / Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 1 ft 0 in 10 ft 11 in None None 2 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 N 2.5 ft2 6 ft 0 in 1 ft2 in None None 3 S=>W 3 Vinyl Low-E Double Yes 0.34 0.31 N 46.5 ft2 1 ft 0 in 11 ft 0 in None None 4 S=>W 3 Metal Low-E Double Yes 0.55 0.34 N 40.0 ft? 2 ft 0 in 1 ft 4 in None None 5 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 1 ft 0 in 0 ft 11 in None None 6 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 N 8.0 ft2 1 ft 0 in 0 ft 11 in None None 7 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 N 31.0 ft2 1 ft 0 in 3 ft 7 in None None 8 S=>W 9 Vinyl Low-E Double Yes 0.34 0.31 N 62.0 ft2 1 ft 0 in Oft 11 in None None GARAGE I # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 j I 1/23/2019 12:58 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 5 FORM•R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 2640.2 144.94 272.59 .363 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ft2 2nd Floor 45 ft2 Proposed Qn 2nd Floor' cfm 156.3 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan r l Feb r Mar r Apr r May rX�Jun rX�Jul rX�AugrX�Seepr Oct Nov r 1 Dec Heatin f X�Jan [X]Feb [X]Mar []Apr [ May [ ]Jun [ ]Jul E ]AuT ] [ ]Oct Nov [X]Dec Ventingl Jan [[[ ]]]Feb [[[XXX]]]Mar [[[XXX]]]Apr [[[ ]May [[[ ]Jun [[[ ]Jul ]Aug [[ ]Se [[[XXX]]]Oct X Nov [[[ ]]]Dec i 1/23/2019 12:58 PM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule'Fype 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80. 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 •78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68' 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 Main Default 8 Ibs/s .ft. 0 ftz Oft 0.3 2nd Floor Name: Test Rater Signature: Rating Compant: Test Rater Date: 1/23/2019 12:58 PM EnergyGaugeOO USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level a)Supply ducts R 6.0 2.Single-family or multiple-family 2. Single-family b) Return ducts R 6.0 c)AHU location Attic/2nd Floor 3.No.of units (if multiple-family) 3. 1 4.Number of bedrooms 4. 5 13.Cooling system: Capacity 40.0 a) Split system SEER 5. Is this a worst case?(yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6.Conditioned floor area(sq.ft.) 6. 2605 d) Room unit/PTAC EER e)Other 14.0 7.Windows,type and area a) U-f actor:(weighted average) 7a. 0.373 b)Solar Heat Gain Coefficient(SHGC) 7b. 0.315 14.Heating system: Capacity 41.0 c)Area 7c. 252.0 a)Split system heat pump HSPF b)Single package heat pump HSPF 8.Skylights c) Electric resistance COP a) U-factor:(weighted average) Ba. NA d) Gas furnace, natural gas AFUE b)Solar Heat Gain Coefficient(SHGC) 8b. NA e) Gas furnace, LPG AFUE f)Other 8.20 9.Floor type,insulation level: a)Slab-on-grade(R-value) 9a. 0.0 b)Wood,raised(R-value) 9b. 19.0 15.Water heating system c)Concrete, raised(R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10.Wall type and insulation: c)Gas fired, LPG EF A.Exterior: d) Solar system with tank EF 1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B.Adjacent: g) Other 1.Wood frame(Insulation R-value) 10131. 11.0 2.Masonry(Insulation R-value) 10132. 16. HVAC credits claimed(Performance Method) 11.Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 30.0 b) Cross ventilation No b)Single assembly 11 b. c)Whole house fan No c) Knee walls/skylight walls 11 c. d) Multizone cooling credit d) Radiant barrier installed 11 d. Yes e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy saving features which will be installed(or exceeded) in this home before final inspection.Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home:R -s Vc nc) Ln) F) Loity/FL Zip: Zephyrhills• FL 1/23/2019 12:58:53 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 Florida Building Code, Energy Conservation, 6th Edition (2017) Mandatory Requirements for Residential Performance, Prescriptive and ERI Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. ✓ SECTION R401 GENERAL R401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statutes)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate code compliance for the building.A copy of the EPL display card can be found in Appendix RD. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.4.1 through R402.4.5. Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to comply with Section C402.5. R402.4.1 Building thermal envelo`PW building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2. The sealing methods between dissimilar materials shall allow for differential expansion and contraction. EJ R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1,as applicable to the method of construction.Where required by the code official,an approved third party shall inspect all components and verify compliance. EJ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air changes per hour in Climate Zones 1 and 2,and three air changes per hour in Climate Zones 3 through 8.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g.(50 pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(1)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. Exception: Testing is not required for additions,alterations,renovations,or repairs,of the building thermal envelope of existing buildings in which the new construction is less than 85 percent of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers or doors,and outdoor combustion air.Where using tight-fitting doors on factory-built fireplaces listed and labeled in accordance with UL 127,the doors shall be tested and listed for the fireplace.Where using tight-fitting doors on masonry fireplaces,the doors shall be listed and labeled in accordance with UL 907. ❑ R402.4.3 Fenestration air Ieakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 1/23/2019 12:58 PM EnergyGauge AO USA -FBC 6th Edition(2017) Compliant Software Page 1 of 5 MANDATORY REQUIREMENTS - (Continued) ❑R402.4.4 Rooms containing fuel-burning appliances. In Climate Zones 3 through 8,where open combustion air ducts provide combustion air to open combustion fuel burning appliances,the appliances and combustion air opening shall be located outside the building thermal envelope or enclosed in a room,isolated from inside the thermal envelope.Such rooms shall be sealed and insulated in accordance with the envelope requirements of Table R402.1.2,where the walls,floors and`ceilings shall meet not less than the basement wall R-value requirement.The door into the room shall be fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403.The combustion air duct shall be insulated where it passes through conditioned space to a minimum of R-8. Exceptions: 1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside. 2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code,Residential. R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1 Controls. SECTION R403 SYSTEMS ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.3.2 Sealing(Mandatory) All ducts,air handlers,filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers,shall be constructed and sealed in accordance with Section C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below. Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5)or (7),Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f),(g)or(i),Florida Statutes,to be"substantially leak free"in accordance with Section R403.3.3. ❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent of the design airflow rate when tested in accordance with ASHRAE 193. ❑ R403.3.3 Duct testing(Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods: 1, Rough-in test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa)across the system,including the manufacturer's air handler enclosure if installed at the time of the test.All registers shall be taped or otherwise sealed during the test. 2. Postconstruction test:Total leakage shall be measured with a pressure differential of 0.1 inch w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.Registers shall be taped or otherwise sealed during the test. Exceptions: 1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building thermal envelope. 2. Duct testing is not mandatory for buildings complying by Section 405 of this code. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. ❑R403.3.5 Building cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. R403.4 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105OF(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3. I R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage,including that ❑ caused by sunlight,moisture,equipment maintenance and wind,and shall provide shielding from solar radiation that can cause degradation of the material.Adhesive tape shall not be permitted. ❑ R403.5.1 Heated water circulation and temperature maintenance systems(Mandatory). Heated water circulation systems shall be in accordance with Section R403.5.1.1.Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2. Automatic controls,temperature sensors and pumps shall be accessible.Manual controls shall be readily accessible. R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump.The system return ❑ pipe shall be a dedicated return pipe or a cold water supply pipe.Gravity and thermosiphon circulation systems shall be prohibited. Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the occupancy.The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and when there is no demand for hot water. ❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515.Controls for such systems shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance with the times when heated water is used in the occupancy. 1/23/2019 12:58 PM EnergyGauge@ USA -FBC 6th Edition(2017)Compliant Software Page 2 of 5 MANDATORY REQUIREMENTS - (Continued) R403.5.5 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. R403.5.6 Water heater efficiencies(Mandatory). R403.5.6.1.1 Automatic controls. Service water-heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). Fi R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)of combustion types of service water-heating systems to be turned off. R403.5.6.2 Water-heating equipment. Water-heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water-heating category.Solar water heaters shall meet the criteria of Section R403.5.6.2.1. EJ R403.5.6.2.1 Solar water-heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol.Collectors in installed solar water-heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential,or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation including:Natural,Infiltration or Mechanical means.Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6.1 Whole-house mechanical ventilation system fan efficacy. When installed to function as a whole-house mechanical ventilation system,fans shall meet the efficacy requirements of Table R403.6.1. Exception: Where whole-house mechanical ventilation fans are integral to tested and listed HVAC equipment,they shall be powered by an electronically commutated motor. R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation shall meet the following criteria: 1. The design air change per hour minimums for residential buildings in ASHRAE 62.2,Ventilation for Acceptable Indoor Air Quality,shall be the maximum rates allowed for residential applications. 2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics, crawlspaces,attached enclosed garages or outdoor spaces adjacent to swimming pools or spas. 3. If ventilation air is drawn from enclosed space(s),then the walls of the space(s)from which air is drawn shall be insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19,space permitting,or R-10 otherwise. R403.7 Heating and cooling equipment(Mandatory). R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This Code does not allow designer safety factors,provisions for future expansion or other factors that affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems.New or replacement heating and cooling equipment shall have an efficiency rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed. TABLE R403.6.1 WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY FAN LOCATION AIRFLOW RATE MINIMUM MINIMUM EFFICACY a AIRFLOW RATE MAXIMU (CFM) (CFM/WATT) (CFM) Range hoods Any 2.8 cfm/watt Any In-line fan Any 2.8 cfm/watt Any Bathroom,utility room 10 1.4 cfm/watt <90 Bathroom,utility room 90 2.8 cfm/watt Any For SI:1 cfm=28.3 Umin. a. When tested in accordance with HVI Standard 916 1/23/2019 12:58 PM EnergyGaugeOO USA -FBC 6th Edition(2017) Compliant Software Page 3 of 5 MANDATORY REQUIREMENTS - (Continued) ' R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.7,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacturer's expanded performance data shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry-bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower CFM provided by the expanded performance data,the design value for entering wet-bulb temperature and the design value for entering dry-bulb temperature. Design values for entering wet-bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multiple-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. , When signed and sealed by a Florida-registered engineer,in attached single-and multiple-family units,the capacity of equipment may be sized in accordance with good design practice. R403.7.1.2 Heating equipment capacity. R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section R403.7.1.1,and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if the design heating load is 1.15 times greater than the design-cooling load. R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.7.1. Fi R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.7.1. R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. R403.8 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections 0 C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403. R403.9 Snow melt and ice system controls(Mandatory) Snow-and ice-melting systems,supplied through energy service to the building, shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F(10°C),and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF(4.8°C). ❑ R403.10 Pools and permanent spa energy consumption(Mandatory). The energy consumption of pools and permanent spas shall be in accordance with Sections R403.10.1 through R403.10.5. Ei R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on-off switch that is an integral part of the heater mounted on the exterior of the heater,or external to and within 3 feet(914 mm)of the heater.Operation of such switch shall not change the setting of the heater thermostat.Such switches shall be in addition to a circuit breaker for the power to the heater.Gas-fired heaters shall not be equipped with continuously burning ignition pilots. R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule shall be installed for heaters and pump motors.Heaters and pump motors that have built-in time switches shall be in compliance with this section. Exceptions: 1. Where public health standards require 24-hour pump operation. 2. Pumps that operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. ❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Where more than 70 percent of the energy for heating,computed over an operation season,is from site-recovered energy,such as from a heat pump or solar energy source,covers or other vapor-retardant means shall not be required. ❑ R403.10.4 Gas-and oil-fired pool and spa heaters. All gas-and oil-fired pool and spa heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013,when tested in accordance with ANSI Z 21.56.Pool heaters fired by natural or LP gas shall not have continuously burning pilot lights. 1/23/2019 12:58 PM EnergyGauge@ USA -FBC 6th Edition(2017) Compliant Software Page 4 of 5 I R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. R403.11 Portable spas(Mandatorg)he energy consumption of electric-powered portable spas shall be controlled by the requirements of APSP-14. SECTION R404 ELECTRICAL POWER AND LIGHTING SYSTEMS R404.1 Lighting equipment(Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or not less than 75.percent of the permanently installed lighting fixtures shall contain only high-efficacy lamps. Exception:Low-voltage lighting. R404.1.1 Lighting equipment(Mandatory).Fuel gas lighting systems shall not have continuously burning pilot lights. I i 1/23/2019 12:58 PM EnergyGauge@ USA -FBC 6th Edition(2017) Compliant Software Page 5 of 5 2017- AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev J Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: v Owner: Jurisdiction: _ Design Location: FL,Tampa o COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air-permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows,skylights The space between window/door jambs and framing,and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above-garage subfloor decking,or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing,or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation,insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts,penetrations Duct shafts,utility penetrations,and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit,or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac 3s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall nytp.nd behind p1pino and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. j Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Concealed When required to be sealed,concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids a.In addition,inspection of log walls shall be in accordance with the provisions of]CC-400. 1/23/2019 12:59 PM EnergyGauge@ USA FBC 6th Edition(2017)Compliant Software Page 1 of 1 Envelope Leakage Test Report (Blower Door Test) Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: ) Permit#: I.Jot:lnformation�• - - Builder: DRH Express Homes Community: Lot: 55/6 Address: City: Zephyrhills State: FL Zip: 141C'Leakage',Tes_t;,Res.ultsl Pa"ssing,results:must'meet'eitlieahe Peff4rmance,•.P�escr�ptive;orERGllilg[hod . -r• �jp ESCRII?TIVi,METHOD?The 6uildin'or.dwellin?unit stialf6eaesteel and;verifieii•:as Fjagiii:an'air lea Rap,fatg;of'nofiexceeding:7 air cli'an es:'erfiouf,:af,`a''ressu�ecof;0:2`iricfi w: 50:Pascals inEClirriafe Zones 1.and2; 1j ...-77 _ _ _ _ -_ ceedin" �. PERFORMANCE=of,ERI;METHOD_-1 he:6uildin or;dwellin sliall be;tested ari8..verified_as fiaving an:air leakage'raf`e".of .�, 9 9 ttieselectedACH(5 vluw 5 e) R , tm rf m 50! :,ACH(50)'spe'cified on.Form R405=201.7-Energy{Calc(Performance)lor='R406`20.17(ERI)` ; 7.000 x 60 _ 22630 — Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans 1-1 PASS 0 Code software calculated When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated must be verified by building department. R402.4.1.2 Testing.Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals) Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statues.or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to thecode official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures. 2.Dampers including exhaust,intake,makeup air,back draft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures. 3.Interior doors,if installed at the time of the test,shall be open. 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed. 5.Heating and cooling systems,if installed at the time of the test,shall be turned off. 6.Supply and return registers,if installed at the time of the test,shall be fully open. i:Testind Company - - - - Company Name: _ Phone: I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above. Signature of Tester: Date of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 1/23/2019 12:59:13 PM EnergyGaugeO USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 = f Duct Leakage Test Report Residential Prescriptive, Performance or ERI Method Compliance 2017 Florida Building Code, Energy Conservation, 6th Edition Jurisdiction: Permit#: :Jobanfor.Fnaton< _• `_ - Builder: DRH Express Homes Community: Lot: 55/6 Address: City: Zephyrhills State: FL Zip: <D:ucf Leakage,Test7'Result:-s: �; 'Prescri'ptive=Methods :Perfolrmance%ERI,:Methotl, . :: System 1 cfm25 Q� Prescripfive Method:; cfm25.(Totalj 1 System 2 cfm25 :,To•`qualfy'as"substantally leakfr0e"i`Qn`Tgtal.mus#be lesstla`nf;or;; equalFto 0 04 If alr handler unit3ls.installed If alr_handlerrurnt Is not .iinstalled':,Qn"Total m.usf be lessi-ftiai:or:e""ual'fo:0:03': System 3 cfm25 r:�rriettiod�meets<the:F"re�uir:ementsin'�acco:rdanee'with#;Section,R40333;- li ir:7iandler un�f installed duriri`<"iesfiri"~•7.0 YES'r 'o� 0'NO; -:9 Sum of any cfm25 " ; ',Is t e„a -7 a -Total of all cfm25 Performance/ERL'Methods`cfm25'=',Oiaf;or Totah r::' 's` :mustsno,'tie' r`.eatertYiaii°f he: To;qualifyiasirg,thls�m`ethod;,Qri t,- g, � - ro osed°'duef+leaka"e'Qn's`'ecif ed'`,oni FormiR405::20:17'o rR9 7-'2017 2605 - Qn P:_-P. v7 ,.;:,, 9� _,I? %% :�.: :,: Total of all Total Conditioned - :'ii:;` systems Square Footage ;=i': - _ ],. Leaka`e T `e.selectea!%on,'Formecif'q,,Qh F6f'R405720.1 :R405.=20'17- Ener` Cale or�R406;2017; p= Ever' 'Cale :or R406=2017:::_::: PASS FAIL Proposed Qn 0.06 I k: • . , i i, Duct tightness shall be verified by testing in accordance with ANSI/RESNET/ICC380 by either individuals as defined in Section 553.993(5)or(7), Florida Statutes,or individuals licensed as set forth in Section 489.105(3)(f), (g)or(i), Florida Statutes. TestriCoin an. g. p Y Company Name: Phone: I hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above,either the Prescriptive Method or Performance Method. Signature of Tester: Date.of Test: Printed Name of Tester: License/Certification#: Issuing Authority: 1/23/2019 12:59:20 PM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 - - Manual S Compliance Report wrightsofte Da Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton Lot 55 Blk 6 Silverado, Zephyrhills, FL Cooling Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 32540 Btuh Entering coil DB: 76APF Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 36683 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042''**A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 100%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 38714 Btuh 106%of load SHR: 84% i Heating Equipment Design Conditions. Outdoor design DB: 40.0°F Heat loss: 28704 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Output capacity: 37299 Btuh 130%of load Capacity balance: 33 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 102%of load Temp. rise: 18 OF I Meets are all requirements of ACCA Manual S. I"1 I1tSOft 2019-Jan-2312:59:57 W 9 ® Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 AC'CA ...press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: E Load Short Form Job: -F f- Wrightsofto Date: Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3098 Fax:727-815-3399 License:CAC033669 Project Information For: DR Horton Lot 55 Blk 6 Silverado, Zephyrhills, FL Design. Information Htg CIg Infiltration Outside db(°F) 40 91 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=33 OF Backup: Input=9 kW, Output=29290 Btuh, 100 AFUE ROOM NAME Area Htg load CIg load Htg AVF CIg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7235 9496 345 399 bed 2 164 2906 2160 138 91 powder 59 950 364 45 15 flex 156 3048 2720 145 114 foyer 75 1416 840 67 35 stairs 44 0 0 0 0 bed4 181 1973 2361 94 99 bed3 184 2272 2862 108 120 wic 60 141 176 7 7 wic 2 32 849 783 40 33 m suite 277 2889 3567 138 150 j bath 135 391 353 19 15 upstairs living 234 1451 3068 69 129 stairs 2 50 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsofte 2019-Jan-2312:59:57 g Right-Suite®Universal 2017 17.0.21 RSU25554 Page e 1 ..press homes\Hayden 4EHB 2605-2nd fl block.rup Calc=MJ8 House Front faces: E bed5 175 1925 2318 92 97 laundry 41 468 913 22 38 a/c 19 0 0 0 0 bath 3 96 791 558 38 23 hall 63 0 0 0 0 Entire House d 2651 28704 32540 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 32540 Latent cooling 4144 TOTALS 2651 28704 36683 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Jan-23 12:59:57 wrightSOW Right-SulteG Universal 2017 17.0.21 RSU25554 Page 2 ACCA ...press homes\Hayden 4EHB 2605-2nd f]block.rup Cale=MJ8 House Front faces: E I Project Summary Job: wrightsoft- Date: Entire House By: Progressive Air Systems, Inc Plan: Hayden 2605 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax 727-815.3399 License:CAGO33669 Project Information For: DR Horton Lot 55 Blk 6 Silverado, Zephyrhills, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22114 Btuh Structure 23550 Btuh Ducts 6590 Btuh Ducts 8990 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh 13113199 0 Btuh Equipment load 28704 Btuh Use manufacturer's data y Rate/swing multiplier 1:00 Infiltration Equipment sensible load 32540 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent (0 cfm) 0 Btuh Heating Coolin (none) Area(ft2 2651 26M Equipment latent load 4144 Btuh Volume�fv) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 36683 Btuh Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh 9 47OF Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.048. cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=33 OF Backup: Input=9kW, Output=29290 Btuh, 100AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right-Suite®Universal 2017 17.0.21 R,9U25554 2019-Jan-23 12:59:57 ACCK Page 1 ...press hornes\Hayden 4EHB 2605-2nd if block.rup Calc=MJ8 House Front faces: E FORM'R405-2017 . RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2017 Florida Building Code,Energy Conservation via the residential Simulated Performance Method shall include: ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(one page)and an input summary checklist that can be used for field verification (usually four pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) i ❑ HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7 ❑ Mandatory Requirements(five pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 1/23/2019 1:14:02 PM EnergyGauge@ USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1 ,;•..y PASCO COUNTY Receipt Date: 4/11/2016 12:19:f D I�C BUILDING CONSTRUCTION SERVICES Receipt Number 1902102 8731 Citizens Drive COUNTY FLQR1tDA Suite 230 ChVN SPACES.I"IBMW NACES. New Port Richey,FL 34654 727-847-8126 ** NOT A PERMIT ** Paid By Check CC Auth Cashier ID Workstation Check 992064 SLEBLANC BCCCP06W Fee Dsscrinflon Amt Pa Id Impact Fee Residential Solid Waste Single Family 12.74 Total Payments: 12.74 Pay—Or Address Phone DR Horton,Inc. 1341 Horton Circle Arlinton TX 76011 Cominents• I City of Zephyrhills Solid Waste 6987 Silverado Ranch Blvd. 05 26 210100 00600 0550 While you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit cord or*-check roes,NOT shown above,Is collected by First Bliihig payment satvke& i myreportslreportsllPASCOPROD)PASCOICustomer Receipt vld.rpt Print Date: 10/21/2019 Page 1 of 1 CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DA E PERMIT f 15tuj 16[(9 THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. c-0 cam. N D lL- LF i It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR P, CITY OF " NOTICE " / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT,f (9 q � -7 c5/ [yee-ctda gc�,�t& 1 _0� -L(�-3,st THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. i It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 78�-��2� FOR P ON or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR CITY OF r " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS_ � V� l DATE l PERMIT .� THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections s ail be made before the job will be accepted. doe X)0 1- k(-2S M S ` f, It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-I $PECTION or other material,until the proper inspector has had ample time to approve the installation. le�lzl OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR