HomeMy WebLinkAbout19-21363 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 21363
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 21363 Address: 37413 PICKETTS MILLS AVE
Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL.
Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: SILVER OAKS VILLAGE
Est.Value: Parcel Number: 03-26-21-0200-00000-0530
Improv. Cost: 20,000.00 OWNER INFORMATION
Date Issued: 6/11/2019 Name: MAGUIRE, COLLEEN
Total Fees: 210.00 Address: 37413 PICKETTS MILL AVE
Amount Paid: 210.00 ZEPHYRHILLS, FL 33542
Date Paid: 6/11/2019 Phone: (570)856-3934
Work Desc: REPLACE 5 WINDOWS S/S
CONTRACTORS APPLICATION FEES
HOME PERFORMANCE ALLIANCE INC BUILDING FEE 210.00
� I
Ins ections Required
FOOTER 2ND ROUGH PLUMB MI C INSULATION EILI
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR SIG TURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-013-780-0021
Building Department
Date Received Phone Contact for Permittin —
111111II /� 1 ^ 11111
Owner's Name Co L.LG. A t�2 Owner Phone Number
Owners Address 3Jy 1LL Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
ll 1, V� �•p
JOB ADDRESS 3�Y13 ICIr4-GTI�S .1 tl LL 6Vi. LOT#
SUBDIVISION 91bh1S&%11!qftJPARCEL ID# E> " "0240•®COC • b O
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED e NEW CONSTR B ADD/ALT 0 SIGN Q DEMOLISH
INSTALL REPAIR
PROPOSED USE = SFR Q COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK n �y� FRAME ,`'� �n'S'TEEL dQ /'��
DESCRIPTION OF WORK RC(/r10k �eGrl�c��i W 1NDuWS ✓J 2,G ITJn, &ZG
BUILDING SIZE SO FOOTAGE HEIGHT
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C.
=PLUMBING $
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING 0 SPECIALTY = OTHER v
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N- FEE CURREn Ly/N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED Y/N FEE CURREn
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREn Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREn
Address DLicense.# p�
OTHER w' t COMPANY f ftal&tfi�
SIGNATURE 1 Y/ N FEE CURREEn I Y/N
Address License# CA"tSO Z0
IIIIIIIIIIIIIIIIIIIIIIIIIII1. tlllllllllllllllllllltlllllllllllllllll
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpsteF;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
""PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and
that all work will be done in compliance with all applicable laws regulating construction, zoning and land
development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify
that no work or installation has commenced prior to issuance of a permit and that all work will be performed to
meet standards of all laws regulating construction, County and City codes, zoning regulations, and land
development regulations in the jurisdiction. I also certify that I understand that the regulations of other
government agencies may apply to the intended work, and that it is my responsibility to identify what.actions I
must take to be in compliance.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. if work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE WCOMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT CONTRACTOR
____'�-74-)
Subscribed and sworn to(or affirmed)before me this Subscribed and swor o(or Irme efore me this
by by 1 LaipffiegC
Who is/are personally known to me or has/have produced Who is/are oersonWW =Qwn to me or has/have produced
as identification. as identification.
Notary Public Notary Public
Commission No. Commission No. 4 2A14 14
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
Z00%. Notary'Public State of Florida
Frank Thompson
My Commission GG 244192
Expires07/31/2022
WqMLIMWW MapeDuo➢
t 1 4D �b'NYrlal�tf7'N��Z-
-FWMgs PAWN •w Pad W 0 Um!xm N•L—Qd
• Pam. �oy�uni0m'oas�a�arp400e�6�g '
_ rf
' / 00SYdd0AJNf107
" - 1u9W1.IM4aW�OP.1.1��1DgY1�LP� Fp9P..��11i�W�A[e'�N!G�P �1 ', .
' 'L13PB�p3Xf da 3�lL0N lYlOA JNtOaD�Y l40>RiOM 0lQ�AM1003tl0339 A34i401LV NV!!O MflOA F4111{M1 -
3B1 18[01'�d9JVNH 14MtB0 30�T43Lp1J�tl fV�•4 a UL eLNDEMM IM SHL ONIA d W �J
tiYJ ONV •83ilLL VGRfD7d Ci 6L1.40wou I 1Wd'¢&LM3LdVFi�.BMW SLNM&Vd L3dMkK OMSMS=3bV
IN313DIEMN"30 371M W•d01IOILV kDG ML HW"lS MW 3HL A9 3"GINMVd MV ZGMW GL DCNbVA
' :(v4•�•aw.+.mb.+•n��+�pa�vowwos,.�c.�ova�s�a:iova�mo
a0•i PwuFit P!A 1 1?uopgdwoo aig 9•!l I-A-"mp�•9U P 5411p 9 '6
_ - i- - � _ ..JaueDA4Pq!u�0��o` 3cr+4uawa±ugd�+1� _
•.:Py��7ox�>Qt;scc�a.s�a!p;om o�go�*gown AgP Idro.o�.o.,w -
�s A�
RV PQPPwd•w Pam•.�0 Aeoi qi-uj op-p A-p-u-*wdn siyio'w0 Rq PWu*!P P OARS 00 w4WR KK•Lvd '[
- "ot4•+�IdaAl4aPo1 -
Q79 - - - 94V
U@FM 0
am
668 /
_ Julm
opts' 9 -VN—Idpl-vm-*m
MUMN
_.._..
-a. ,�P'�WpILMdWS'••dP�+rl1
-� sjjj4jAgdsz anN3nV IIIW SIJ-gNDld WFL£
_.
. . '.,".•.-....... .-'N33I1003211f1JVW'"'
- - aMOm4p14q.Auoo.aw aam, Mamrggwumipqmio "'B
_ . ... eare,o)eZIB Woop to pug moptgm omq.ws P .a lam'
ZbS££Id'9-mHHAHd3Z 3nN3AV IIIW ellamOid wra:'
M10°Jd NIPS a0£S 101 LM SJd St 9d 2NO I S O 3 .°H P-d"�'djD`°�O .1
pY:*•=P •N►wPd q a�•ms�•0
*mid'��t • a pw�u•dmd tw w WIT w• dw io0• R�•!w Q3lRJi8190Nf13H1
lAHOB9/i311WW d0 3dIM
- oeso-00000-0ozo-LZ-z-£o
Aaj)0,Qdut0D 2,9 J-JaJJ h UnoD oasnd `¢•yd�iaM o 'S vjnvd
00'0:11 00'0=S0 00'0L:osN 996990Z:ldob WV 60:60 6WZ/0Z/90
L jo L 96ed BOB� Jd 8066>18 210 908VB06I OZ M:USNI -
COUNTY OF PASCO )liga�.
STATE OF FLORIDA, NGiSA
!�'�\,
THIS IS TO CERTIC CQPY OF O EEDOCUMEN E
TRUE AND CORR I TNIS:OF.F1C � "
U UBL
;PlCPE ORp "IS �ti.
`ON FILE Of
F. �' ICIAL�EA2
MY HAND A D =r ,
t1TNESS1 F Fn y,tr„sc
DAY 0 `... ,
?A.LfLR S•O' lL=CLERK&C MpTROLLER
�f
DEPUTY CLERK
BY OF
f' S13828
Colleen Maguire
2 F 3
1.3
.!q. �S
21
16
BAS
1�] FrMO41
52
((V.
1�
FOP IV
42
Last Revision Date:0918 Page 3 of 6
PRODUCT.APPROVALSUBMITTAL SHEET
A Iloatlon/Permit#: Building Address: 6 ' owner; I Contractor: is
Openings. Sllding Glass Doors,Exterior Swing Doors, Overhead Doom, Flxea Olass, Windows, Mullions, Skylight's
**Pressure Product Approval Product Model#or Glees Attachment Approval Expiratl,
*Qty Manufacturer Category, Number/So #, Name Serlee a/Slae Method Ent it Date
Is zma UN
79
wy-OW !S79D-9
12
0 '
Service Finance i 6
AOA
sent to Measure: Tuesday,April23,2019 Notes: 19ssoly
Date Measured: '
0.
Class/Design Pressure to PSF 45(8.64) Wind Velocity In MPH 138 S13828
Home PerformonceAllionce
Applicant Colleen Maguire Frame Type Gp�-
Applicant Phone/Email (570)856-3934 :calleenmOnn.ii.usf.edu Exterior Siding r
Co-Applicant Year Built 2003
Co-Applicant Phone/Email i Bucking Req
Contract Date 4/11/2019 Color i L�
Home 37413 Picketts Mill Ave Grids .�
----------
Address Zephyrhills,FL 33542 — ------- Frosted
County Pasco' Impact
Sales Rep Alex Reviczky Non-impact
Phone Number (407)924-3460 Window Shields
Email Address atexreviczky@yahoo.com Door Shields
Supervisor Aaron Weiand CuSt`Init ..X Ciistom`er=agrees Eo the above'
Nr Room W H Style Series OBS Temo Screens Grids Notes
3 17 5/.?-r _A /Z fv.-I::; Y rs
Iry S.°v7 !> v /v / '
7
e '
9
So
11 -
u
. 13
14
ss
i6
17 .
16
19
m
t Yl(jlpj f Do you have an HO Yes or No
Customer Signature; / Date: / / 9 (Fleasedrdeme)
Measured By: / .rZ/✓"''- "--
Do you live in a Flood zone; Yes or No.
Date Measured: J / (Hieasedrdeone)
last Revision Date:0918 Page 1 of 6
Colleen Maguire $13828
OBS Temp Screens Grids Notes
22
u
23
24
2s
26
27
28
Caulk.... Trim.... • Ta cons.... Foam
O01
� G
G
i
I
Last Revision Date:0918 Page 2 of 6
5/14/2019 Florida Building Code Online
i
g C Q
BCIS Home Log In E User Registration ( Hot Topics Submit Surcharge Stats&Facts Publications ( Contact Us 1, BCIS Site Map Links 1 Search 1•
Florida
as Product Approval
USER:Public User
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL15780-R9
9^d
Application Type Revision
Code Version 2017
Application Status Approved_
Comments
Archived s...i
ALL WORK SHALL COIVIPLy
Product Manufacturer Soft-Cite LLC CODES FLOR�pA BUiLDIiV WITH PREVAILING
NATIONAL ELECTRIC CODE,
CODE,
Address/Phone/Email Philipp P
0 THE C,0'p�+
(330)528-113s0 DIN OF�EPH�RHILLS .
PLangan@soft-lite.com �CE
Authorized Signature Vivian Wright
rickw@rwbldgconsultants:c
Technical Representative ot
L' Id
Address/Phone/Email FC=
ILI
Quality Assurance Representative
Address/Phone%Email
Category Windows
Subcategory Double Hung
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
1 .Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity Farabaugh Engineering and Testing,Inc
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan J. King, P.E.
ti Validation Checklist-Hardcopy Received
Certificate of Independence FL15780 R9 COI (d)Certificate of Independence.pdf
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2008
AAMA/WDMA/CSA101/I.S.2/A440 2011
AAMA/WDMA/CSA101/I.S.2/A440 2005
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
TAS 201, 202, 203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW6yPiCnocELknenknQR5cQUe6yvwOg5lLg%3d%3d 1/3
5/14/20,19 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 11/21/2018
Date Validated 12/11/2018
Date Pending FBC Approval 12/16/2018
Date Approved 02/19/2019
Summa of Products
FL# Model,Number or Name Description
15780.1 a.'"Imperial LS DH12"Double Hung Extruded PVC Double Hung Window-(X/X Configuration)
Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No LL15780 R9 II (a)Inst 15780.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.1 for Design Pressure Ratings,any FL15780 R9 AE (a) Eval 15780.1.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15780.2 b. 95400 DH54(G5405)"Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS780 R9 II (a)Inst 55780.2.pdf,
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant: No I Created by Independent Third Party: Yes
Design Pressure:,N%A Evaluation Reports
Other:See INST 15780.2 for Design Pressure Ratings,any FLIS780 R9 AE (a) Eval 15780.2.pdf
additional use limitations, installation instructions and product Created by.Independent Third Party: Yes
particulars.
15780.3 c."5400 DH54(G5405)"Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15780 R9 II (a)Inst 15780.3.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 1.5780.3 for Design Pressure Ratings,any FLIS780 R9 AE (b) Eval 15780.3.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15780.4 d. "5300 DH53(G5305)" Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS780 R9 II (a)Inst 15780.4.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.4 for Design Pressure Ratings,any FL15780 R9 AE (a) Eval 15780.4.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.5 e. "5300 DH53 (G5305)"Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R9 II (a)Inst 15780.5.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.5 for Design Pressure Ratings,any FL15780 R9 AE (b) Eval 15780.5.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.6 f.Series"Barcelona" Model "DH30I" Extruded PVC Double Hung"Impact"Window, Missile Level"C"
-(X/X Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R9 II (d)Inst 15780.6.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E. 43409
https:%/www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAinEOW6yPiCnocELknenknQR5cQUe6yvwDg5lLg%3d%3d 2/3
5/14/2Q19 Florida Building Code Online
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.6 for Design Pressure Ratings,any FL15780 R9 AE (b) Eval 15780.6.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.7. g.Series."Barcelona" Models"DH30I" Extruded PVC Double Hung"Impact"Window, Missile Level"D"
&"DH30PI" - (X/X Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R9 II (c) Inst 15780.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.7 for Design Pressure Ratings,any FL15780 R9 AE (b) Eval 15780.7.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.8 h. Series"Barcelona" Models"DH30I" Extruded PVC Double Hung"Impact"Window,High Velocity
&"DH30PI" Hurricane Zone-(X/X Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15780 R9 II (c) Inst 15780.8.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.8 for Design Pressure Ratings,any FL15780 R9 AE (b) Eval 15780.8.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
r 157$9� i.a es"Barcelona"Models.t"�D—H30" Extruded PVC Double Hung"Non-Impact".Window-(X/X
6H30P""`' 1 Configuration)
Limits of Use i^' Installation Instructions
Approved for use in HVHZ: No FL15780 R9 II (b)Inst 15780.9.pdf
Approved for use.outside`HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact-;Piesi!stant:.No -I Created by Independent Third Party:Yes
Design-Pressure:N%A Evaluation Reports
Other:See INST 15780.9 for Design Pressure Ratings,any FL15780 R9 AE (b) Eval 15780.9.pdf
additional use limitations, installation instructions"and product Created by Independent Third Party:Yes
particulars.
. Back Next
I
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy tatement::Accessibility Statement::Refund Statement "
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal.address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
Rhack M
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW6yPiCnocELknenknQR5cQUe6yvwOg5lLg%3d%3d 3/3
oft-Lite
111 lows N:J 2 '65"i- . -2:2
o
Bringing quality to light. o�o
10250PhilippParkway fl rlttt� 0 c"ry ,a
Streetsboro,Ohio 44241 co
m v o xzq
_ N tom' Sm�w
SEE CHART FOR SEE CHART FOR n Ng got tt a
8�4RCELON�4tt �- FRAME SIZES FRAMESIZES w
Model "DH30" and "DH30P" ' E oz
I�
-- o v
DOUBLE HUNG WINDOW/
"NON-IMPACT'
0
H OW
o �cr
GENERAL NOTESFZ
0
1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida w �// %// a a
Building Code(FBC)structural requirements excluding the"High Velocity Hurricane
Zone"(HVHZ).
3 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment
e to base material shall be beyond wall dressing or stucco.
3. When used in areas requbing wind bome debris protection,this product Is required to be z.
aprotected with an impact resistant covering that complies with FBC Sections 1609.1.2& U�11 N o
Riot 2.1.2. Model"DH30" Model"DH30P"
4. For 2,stud framing construction,anchoring of these,units shall be the same as that
shown for 2x buck mcisonry construction.
_..... .MAXI
_
..r-:•_:_.-=�;:'2;:f:`.-;;`_.:-.>r': -aY_:..:M/U(ia.:i•"i :r'.--,.:':. 'DESIGN PRESSORE;(PSff= o
5. Site conditions that deviate from the details of this drawing require further
a TYRE
engineering analysis by a licensed engineer or registered architect. a:..-._,..__ "_."DIMENSION, ,DIMENSION `POSRIYE .;NEGATNE:.
7
"DH30" 36.0"X 720 28.125'x 32.00" G1 +50.0 -50.0
TABLE OF CONTENTS
SHEET# DESCRIPTION "DH30" 40.0"X 63.0" 32.125"x 27.125" G1 +55.0 -55.0 'z
.13
I Typical elevations,design pressures and general notes _
zo
2 Hodzontal cross sections a+� 9/19 17
3 Vertical cross sections "D=' 54.0"X 76.0" 46.25"x'34.0(r GI +35.0 -35.0 scut N.T.S: m
g4 Buck and frame anchoring m+e• JK
5 Components "DH30P" 40.0"X 63.0" 32.125"x 26.625" G1 +55.0 -55.0 ftSHEEr.. @(9
3
6 BT of materials and glazing detail
n
"DH30P" 54.0"X 76.0" 46.25"x 33.125" G1 +30.0 -30.0
G
R:\Clents\Soft-URe Permanent\A-Florida Product Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)-RI\FL-15780.9.dwg,2 -
O2
a0F
O T�O
3 N�
m.-.O
09ID
N
ID..
QO
7
O
�cO vZ W W INN NI—+I _
0 O
oZ a m a
oA Wa o
' O
N
N �
Z n
W
.OD y n
prn
N N
rn T�1
A 0 = n 5 A
a ) W ?
� El
00
N
m
R
Z u Oo rn
m
m
Ln 0
a D
�3
22
IA IA
N W m
y
€o
17
ca o
A ❑ FR
y
❑ o �U1U1
n
n C CIO .. .
O c1
tl OD m O V I�
m �
O
I� cm
����V.••VOplj'ge'y'�J'��i� .
No.43409
JUNE 11,2018
PRODUCT: Document. Proparod By:
I�. ndon F. Schmidt �i;�`��' �OR1D1`.••' ���
SOFT—CITE WINDOWS Ly
;t tD P.E. No. 43409
IN �d /7� ////lllllllll
V•• y PART OR ASSEMBLY: ..K BUILDING CONSULTANTS, INC. '
Io x !n 1 6 11 18 ADDED FRAME SIZE JK t/lJ P.O. Box 230, VDlrieo, FL 33595
O1 to v NO DATE BY HORIZONTAL Phone No.: 813.659.9197
REVISIONS CROSS SECTIONS FBPE G.A. No. 9813
®2017 R.W.BUILDING CONSULTANtS INC.'
R:\Oients\Soft-Ule Permanent\A-Florida Product ApprOvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)-RI\FL-15780.9.dwg,3
1-114'MIN. 1-114'MIN.
EMB.(TYP.) EMB.(TYP,)
_ !J
m n � N
wN Wr A
� � t
O >
0.0 CCU
O22
y
,� Z ttt is
{O
0
m
W
1-114'MIN.
a EMB.(TYP.)
.a No .o is a D m
wa v ( ww n
0� W oa
o10
o con
a to
-0H to
` N V
w w z a Q
. o N iA .
1-114"MfN.
EMB.(TYP,) G1
N
m m
ty
❑ N
P
W Ch
c
0 O
t�
O ❑
N ® 3
M ,
V7 N
- CDA' V mow.. O V ``ttttllpNJl//�
1-114°MIN. is ��`* VBF�r rrr'
EMB.(TYP.) ���* No,
JUNE 11,2018' PRODUCT: Documents Prepared By: A�
tW SOFT—CITE WINDOWS L don
P..E NoF434hmidt rrrrr S09 sjQ�A�.
INC.
� '� � PART OR ASSEMBLY: GF BUILDING CONSUt.TAKiS, INC.
Io Ei c- in�I' 1 6 11 18 DDED FRAME SIZE JK CW P.O. Box 230.Valrfco, FL 33S95
O0 `t NO DATE BY CROSS SECTIONS PhonO No.: 613.BSB.9197
REVISIONS FBPE G.A. No. 981.3
0 20 17 R.W.BUH-VING 0-ULTANtS iNO.
o♦♦♦�``"`i� a►►►����.
,``p'�• Ln
4 FOR WIDTHS GREATER THAN 40 a o J_d n
X.
gyp 7 o y p
'v A. Z fig` d`m
• :�•
n 1
U N••Z
v U p Z
U
D N &=g 9m2W
e N i o t a
TYP. SASH v W LL"� m a a
BUCK `o E Z
BUCK v FRAME g w (�
_ o Sd �a
MEETING —————— ———— MEETING
RAIL ------ ---- } RAIL o
2X BUCK F o czi
MASONRY o iE
MASONRY `* OPENING 1XBUCK G i W
OPENING DIRECTTO H Z_ J
SASH
MASONRY eo 5 m
F HEAD&JAMBS N o
d (TYP•) o .
Ir
j a U
F' f I H
0 a DD
a �m
s `P
3
BUCKANCHORING FRAMEANCHORING
i N z
z
0
3 N
N
CONCRETE ANCHOR NOTES:
G; 1.Concrete anchor locations at the comers maybe adjusted to maintain the min.
edge distance to mortar joints. o
2. Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to o
maintain the min.edge distance to mortar joints,additional concrete anchors 3
g maybe required to ensure the"MAX.ON CENTER"dimension are not exceeded. m "
3. Concrete anchor table:
8 rl ..E.......... .1:.: -
.IN::CIEARANGE; yUN7CLEARA.NCE:
:A .HA
...:.....:_: .. TO.MASONRY'r': 'TO:ADJACENT
m
.:SIZEMUDMENT. : o
ED Z °;::a: ::.:.-
.,.......... A_D
..... ..................................................
0
ITW Dim 9119117® 1 4" 1.1 4" . o
TAPCON j j SCAM N.T.S.
€ ELCO M.BY. JK m
& ULTRACON® CHYL ar: LFS 3
WOOD SCREW INSTALLATION NOTES:
DHAWNG ND.:
I.Maintain a minimum 5/8"edge distance,1"end distance,&1"o.c.spacing of FL-15780.9 0
n wood screws to prevent the splitting of wood. N
SHET 4 Or 6
o — —
R:\Clients\Soft-Ute Pe=anent\A-Florida Product Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)-R3\FL-15780.9.dwg,S
A J
_ Ul 2.87'�
b O
0.059" ,{o
ee y
A
O C7
1.44"
A
`0 w o
O i OAl" oI;� A..L
10.86' •I .I O � �
w N
O.OS' y r F
! n 0.093" a D
I Ti, I
A F�-1.83" I
1.21" 3
1.07. 1.05"
Tit
� a
y 1J2
�{ 1.21"
o
(12
o T o
- o
1.96" 1.21" 0.39" ' o
1.07r" wt yo
p 10' m A = W ca -
a r y a 0.093" y 0
V v
1.os. LL0.84'
A �r-I.TT'---�
1.96 h-1.63
4.8T'
o
0.06S'
o W
II � 0.9S' �--
o
L � y
o
3
00 1.96"
w
H G1 A
tS
O a y m y
O �O c
N
2.39"—I
m
a
o _J_ �11111111///j
Y„
0.2T' `` V• �` ��.
/AiPt!:ZZ No.43409
JUNE 11,2018-
Q. PRODUCT: Documents Prepared 9Y:i�
ty SOFT-CITE WINDOWS Lyndon F. Schmidt '� S�O �d
I� I R \ P.E. No 43409 i`�r�1VA1.�11����
t— -1 -PART OR ASSEMBLY: a q��BUILDING CONSULTANTS, INC.
C, z N 1 61711 a DDEO FRAME.SIZE 6Y COMPONENTS UV P,O, Box 230, Valrrco, FL 33595
DATEPhone No.: 813.659.9197
REVISIONS FBPE CA. No. 9813
®20 1 7 R.W.BUILDING CONBUL—Nba IND.
rtFM BILL OF MATERIALS .. * •
`�O•:' ��
A IX BUCK SG>=0.42 WOOD �x"uf' o Q_ZLLn
B 2X BUCK SG>=0.42 WOOD
Nt
C 1/4"MAX.SHIM SPACE - Z o a,
D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL ����••.. �p�.` F u°,n
PSI MIN.CONCRETE CONFRMNG
E MASONRY HOLLO
W WBLOCK CONFORMING TO AOSTMIC OTO ACI CONCRETE '''��i�• � `` o n°°i
r nna
F #8 X 7'PPH SMS(1 3/8 •;
MIN.EMBEDMENT) STEEL U No 4
G 1/4"X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL o o E z m o 0
H 1/4"X 2-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL ` °a S `o a
1 FRAME' PVC n �'t mm a Q.
2 HEAD* PVC z`
3 WEEP HOLE COVER' PVC E o
o dui.
4 SILL ADAPTER' PVC
5 TOP LIFT HANDLE' PVC
6 KEEPER RAIL" PVC
7 LOCK RAIL* PVC y -�
8 PLAIN STILE' PVC o �
9 GLAZING BEAD' PVC
10 BOTTOM LIFT.RAIL" PVC
11 REINFORCEMENT(6065-T5 ALUM) ALUM. 5/8"GLASS BITE 1/2'WIDE DBL SIDED GLAZING TAPE m o
12 REINFORCEMENT(6065-T5 ALUM) ALUM.
13 REINFORCEMENT(6065-T5 ALUM) ALUM. 7/8"THICK `2 a,o
14 HEAD POCKET INSERT* PVC 1/8"ANNEALED OR TEMPERED GLASS of o mQ
15 SLOPED INSERT* PVC m
16 SLOPED SILL* PVC a a
G 20 LOCK m
21 LOCK KEEPER
ILI
3 25 TILT LATCH AIR SPACE
0 26 #8 X 1"PFH TEK STEEL
27 #6 X 1"PFH TEK STEEL 1/8'ANNEALED OR TEMPERED GLASS
28 WEATHERSTRIP(187-270TRI-FIN) rn
29 BULB SEAL STEEL INTERCEPT SPACER w o
N —
30 BULB SEAL G1 GLAZING DETAIL, w N
$ 31 PIVOT BAR STEEL 2
32 #7 X 3/4"PFH TEK STEEL
33 BALANCER BRACKET
•THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY i
g EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". ro
go
•'qc O o
^z u
DAB 9 17 z
5 5
5 s N.T.S.
€ DWG.Err. JK m
CM BY. LFS ;
DRAWING NO. �
.9 FL-15780.9 0
p N
SHEET 6
OF-6
s
5/14/2019 Florida Building Code Online
A
O ► ' Y O B * � � tl V C
BCIS Home ( Log In E User Registration Hot Topics i Submit Surcharge € Stats&Facts Publications E Contact Us BCIS Site Map Links Search i
Florida .
M; f Product Approval
y
USER:Public User
a
2
X;c3mx .
Product Approval Menu>Product or Application Search>Application List>Application Detail
o FL# FL15781-R9
Application Type Revision
Code Version 2017
Application Status .Approved
Comments
Archived (:J ALL WORX SHALL
CODES"FL®121b COrVIPLY WITH p
Product Manufacturer Soft-Lite LLC NATIONAL ELECr$UILDING CODE,.�EVAILING
Address/Phone/Email 10250(330) 5281l.ipp Park r11036 4 INANCES ® ZEI°HYRHILLS
PLangan@soft-lite.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
JU
Technical Representative CI�-� t° ^�j; p'"
Address/Phone/Email `� r' I
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
( Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity . Farabaugh Engineering and Testing, Inc
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan I King, P.E.
Validation Checklist-Hardcopy Received
Certificate of Independence FL15781 R9 COI (c)Certificate of Independence,pdf
Referenced Standard and Year(of Standard) Standard Year
AAMA/W DMA/CSA101/I.S.2/A440 2011
AAMA/W DMA/CSA101/I.S.2/A440 2008
ASTM E1300 2004
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
TAS 201, 202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9TaOMFDxJQM7zrlDnCZDWfYzmDT6ZexQ%3d%3d 1/4
i
5/14/2019 Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 11/21/2018
Date Validated 12/12/2018
Date Pending FBC Approval 12/18/2018
Date Approved 02/19/2019
Summa of Products
FL# Model,Number or Name Description
15781.1 a. "Imperial LS DSL12"Double Slider. Extruded PVC Double Horizontal Sliding Window-(XX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9.II (a)Inst 15781.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.1 for Design Pressure Ratings,any FL15781 R9 AE (a) Eval 15781.1.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.2 b. "Imperial LS TSL12"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (a)Inst 15781.2.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.2 for Design Pressure Ratings,any FL15781 R9 AE (a) Eval 15781.2.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.3 c. "5300 DSL53(G5352)"Double Extruded PVC Double Horizontal Sliding Window-(XX
Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (b)Inst 15781.3.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST.15781.3 for Design Pressure Ratings,any FL15781 R9 AE (a) Eval 15781.3.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.4 d. "5300 DSL53(G5352)"Double Extruded PVC Double Horizontal Sliding Window-(XX
Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (b) Inst 15781.4.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.4 for Design Pressure Ratings,any FL15781 R9 AE. (a) Eval 15781.4.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.5 e. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window- (OX or XO
Slider Window Configuration)
Limits of Use. Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (b) Inst 15781.5.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.5 for Design Pressure Ratings,any'- FL15781 R9 AE (a)Eva] 15781.S.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.6 f. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO
Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15781 R9 II (b) Inst 15781.6.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 I
hfps://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQM7zr1 DnCZDWfYzmDT6ZexQ%a3d%a3d 12/4
5/14/2619 Florida Building Code Online
Impact Resistant:Yes Created by Independent Third Party: Yes
Design pressure:N/A Evaluation Reports
Other:See INST 15781.6 for Design Pressure Ratings,any FL15781 R9 AE (a) Eval 15781.6.pdf
additional use limitations, installation instructions and product Created.by Independent Third Party':Yes
particulars.
i
15781.7 g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (a)Inst 15781.7.p ff
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, RE. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design'Pressure: N/A Evaluation Reports
Other:See INST 15781.7 for Design Pressure Ratings,any FL15781 R9 AE (a) Eval 1S781.7.Pdf
additional use limitations,installation instructions and product Created by Independent Third Party': Yes
particulars.
i
15781.8 h. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15781 R9 II (a)Inst 15781.8.p ff
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, RE. 43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.8 for Design Pressure Ratings, any FL15781 R9 AE (a) Eval 15781.8.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
i
15781.9 i. Series"Barcelona" Model "SSL30I" Extruded PVC Horizontal Sliding "Impact"Window,Missile Level
"C"Excludes Wind Zone 3 and 4(XO or OX Configurations)
Limits of Use Installation Instructions
Approved-for use in HVHZ: No FL15781 R9 II (c) Inst 15781.9.p ff
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, RE)43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.9 for Design Pressure Ratings,any FL15781 R9 AE (b) Eval 15781.9.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.10. j. Series"Barcelona" Model"SSL30I" Extruded PVC Horizontal Sliding "Impact"Window, Missile Level
"D"Includes Wind Zone 4(XO or OX Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS781 R9 II (c)Inst 15781.10 df.
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, RE1 43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:'See INST 15781.10 for Design Pressure Ratings,any FL15781 R9 AE (b) Eval 15781.10.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
i
15781.11 k.Series"Barcelona" Model"SSL30I" -Extruded PVC Horizontal Sliding "Impact"Window,High
Velocity Hurricane Zone Large Missile(XO or OX
Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS781 R9 II (c)Inst 15781.11.0df
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, REj 43409
Impact Resistant:Yes Created by Independent Third.Party:Yes
Design Pressure: N/A Evaluation Reports I
Other:See INST 15781.11 for Design Pressure Ratings,any FL15781 R9 AE (b) Eval 15781.1l.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.12 I.Series"Barcelona"Model "TSL30I" Extruded PVC Triple Horizontal Sliding"Impact"Window, Missile
Level "C" Excludes Wind Zone 3 and 4(XOX 1/4-1/2-1/4 and
XOX 1/3-1/3-1/3 Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (c) Inst 15781.12.pdf
Approved for use outside HVHZ:.Yes Verified By: Lyndon F.Schmidt, P.E. 43409
Impact Resistant:,Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.12 for Design Pressure Ratings,any FL15781 R9 AE (b) Eval 15781.12.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.13 m. Series"Barcelona" Model Extruded PVC Triple Horizontal Sliding "Impact"Window, Missile
"TSL30I" Level "D" Excludes Wind Zone 4(XOX 1/4-1/2-1/4 and XOX
1/3-1/3-1/3 Configurations)
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQM7zr1 DnCZDWfYzmDT6ZexQ%3d%3d 3/4
5/14/2619 Florida Building Code Online
Limits'of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (c)Inst 15781.13.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.13 for Design Pressure Ratings,any FL15781 R9 AE (b) Eval 15781.13.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.14 n. Series"Barcelona" Model"TSL30I" Extruded PVC Triple Horizontal Sliding"Impact"Window,High
Velocity Hurricane Zone Large Missile(XOX 1/4-1/2-1/4 and
XOX 1/3-1/3-1/3 Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15781 R9 II (c)Inst 15781.14.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.14 for Design Pressure Ratings,any FL15781 R9 AE (b) Eva[ 15781.14.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
�578VA! -o_Series,"Barcelona"Modele'DSL3W, "Extruded PVC Horizontal Sliding "Non-Impact"Window(XX
-Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (b)Inst 15781.15.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant No,\, Created by Independent Third Party: Yes
DesttgnwPressure:_N/AS' Evaluation Reports
Other:See INST.15781.15 for Design Pressure Ratings,any FL15781 R9 AE (b) Eval 15781.15.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.16 p. Series"Barcelona" Model "TSL30" Extruded PVC Triple Horizontal Sliding"Non-Impact"Window
(XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R9 II (b)Inst 15781,16.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.16 for Design Pressure Ratings,any FL15781 R9 AE (!) Eva[ 15781.16.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy atatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mail to this entity:Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please-
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please.click here.
Product Approval Accepts:
' ® eClr�cA � •
.Credit Card
Safe
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgt3elSA]nEOW9Taf7MFDkJQM7zrIDnCZDWfyzmDT6ZexQ%3d%3d 4/4
40
BYLYtghigtuality to Ii&. SEE CHART FOR FRAtvtESIZES 4� m
16250PhlippParkway ��� 1 II{{{. a M D.z°
Streetsboro,Ohio 44241 a a••
a yaZU
l $Lm 9 6 c W
"BARCELONA"' \i� m 0.a�
f 1 ` `_
Model "DA30"
SLIDING I i 1NDO ■
(r7 Z
"NON-IMPACT' a
j X z a�
t /\
w w �In
J
W ¢�
w. FO
h SJ y 00 Ufn
GENERALNOTES a �
f f CL i 4
1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida �// �//
Building Code(FBC)structural requirements excluding the"High Velocity Hurricane Zone" m
n (HVHZ).
v ---------------------
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment
to base material shalt be beyond wag.dressing or stucco.
g 3. When used in areas requiring wind bome debris protection,this product is required t' be o
= protected with an impact resistant covering that complies with FBC Sections 1609.1.2& N N
R301.2.1.2. n
4. For 2x stud framing construction,anchoring of these units shall be the some as that shown
for 2x buck.mosonly construction. U
a � z
5. Site conditions that deviate from the details of this drowing require further m w z
A
engineering analysis by a licensed engineer or registered architect. N a o �
n
— z
TABLE OF CONTENTS . :..� -
AX:;" �bESIGN�PRESSURE' S z a
SNEET@ DESCBlt7/0N �GtAS$"�
DAM 10108177
Z
1
€ _ TYPk al elevations,design pressures and general notes
2 Horizontal cross sections
"=,M�w�2Stt1VE;= 'FEGAT(i%k'n
�
3 Vertical cross sections
73.0"X 63,0" 31,437'x 54.375" GI +40.0 -40.0 °W BY. JK m
4 Buck and frame anchoring cHK er: tFS
x 5 Components aR WIW NO-' tt
6 Bill of materials and glaring decal
63.0"X-04.0" 26,437"x 35,375" GI +55.0 -55.0 FL—75787.15 r
0
v SHEET t or 6 N
R:\aients\Soft-Lite Permanent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-15781.15.dwg,2.2
N
M
_ to
0 v mA
�Z
0
CY "
'0
m Q
Z
� W N
Zs,
O
• Q �
Q
•O N�
N A O
N I
P
n c. V NN
O W S m
O N
Z o D
oa
N �
n
0 " N
Z
O lO O
A
•O to
A
N Qf H � � p -• � .
O � p m
A U Nw a
�z
O �O
H f1 C IOU
T a _
0
O m O
Z rn
y0
LIM
A O o
. z
• ```1un urrrr�r�
Gr.,C/Y +No 43409 �
PRODUCT: Document.Prep.red'BY•--11
• ;
SOFT—LITE WINDOWS Lyndon F. Schmidt �� ••• ��0�•'•6����
IN) o \ P.E. No. 43409
z
m_ r- —1 m PART OR ASSEMBLY: /m� BUILDING CONSULTANTS, INC.
X in 1 1/25 18 REVISED PRESSURE RATINGS LFS V v RO. Box 230, Valrico, FL 33595
IO u v NO DATE BY HORIZONTAL Phone No.: 813.659.9197
REVISIONS CROSS SECTIONS FBPE C.A. No. 9813
2017 R.W.BUILDING CONBULTANtB INC.
R:1Clients\Soft-Lite Pemanent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Dmv ings\FL-157816TH ED(2017)\FL-15781.15.dwg,32
m N m" m
C) W Go
v da
w` E o
�m a
m o
0cn
o oa
09
y
m y O N
OD
. y
1-IMMIN. ? 1-1 MINI
EMB.(IYP.).
m Im
a w aD co
R n n
n •O IA CID
a
W N •
£a o o
x�
0�
n o N
z CID0 G) Oo
m ._.
1-IM MIN. ➢ 1-IM MIN.
EMB.(TYP.) EMB.(TYP.)
N
m .N m m m -
C1 w cow n =
w w oa o
. •. �� t.. : a I o
y"
o y O o I .
V y N
ca m
S Z CD A
m
y
1-1/4"MIN. 1-1 X MIN.
EMB.(TYP.) EMB.(TYP.)
sglyl/44i
•ZS'{rP�=,,,*yam * .*�
i x gg s PRODUCT: 0ocumente Properod Br.
E� SOFT—LITE WINDOWS Lyndon IF Sohmldt i��**••FY...... ,••
O P.E. No. 43409 •�ONAL
IW o Z\ /llllll
m •• r— —I co PART OR ASSEMBLY: /mom BUILDING CONSULTAN SM.
x V1 1 1 25 18 REVISED PRESSURE RATINGS LFS t/V�P.O.I Box 230, Valrico°I Ell DATE BY VERTICAL phone No.: 8t3.659
REVISIO S CROSS SECTIONS FEIPE CA No. 98
0 2017 R.W.GUILDINO CDNel1LTANte INC.
i
r
M
�U 1
m
i
�,
4
1
W.
. Z
S,(TYP.) SASH !nP I 4(nP I �,��'rrr P `` \ o - -
Fr I r 81(TYP-)--{ :n nun m
A 4 , f% g 1 g 9 C IL
8 �
E oZ
EW
I I I I NJS
Y2XBUCK o a
a II TYP. BUCK II BUCK II — itFRAME II 3
n II MASONRY II (TYP.) 2
MASONRY II OPENING II 3LU
OPENING II II
II II
z
o II ii o c
_-
G I I T I N Wo cYi
I I of m
t nU i a a
V
12 BUCKANCHORING
FRAME ANCHORING z.
K �
z
o W O
aj
y
CONCRETE ANCHOR NOTES: W
1. Concrete anchor locations at the comers may be adjusted to maintain the min. a
edge distance to mortar joints. y
2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to s
amaintain the min.edge distance to mortarjoints,additional concrete anchors i
may be required to ensure the"MAX.ON CENTER"dimension are not exceeded.
g
3.Concrete anchor table:
N Q
::::.::::::::::::..::::.::•::;:.;::.::;::•:.,:..;:.:;:;;.:y:.y,::::.y;i N:?;G7J 4NC ::M.IN:CYEA.RANCR. o
a ANCHOR AN :':;y.;;:MIN......, :>:70 MASONRY i0 ADJACENT ;
m
EYiAB�[�me..:• Z
...:::....... :.i st:;.::: :i;S(ZE.x:: ..........................::: :.';::::::..- .. :...... o a
W .......:.�::•::�.......:::•.....:.::::.-:::::.-:.-:.•:::::::::::.�:::::.-::::::..::::::.:::.:EDGE:::::::;•r:�:�r;::�;;�;;:�;'ANCHOR::a:;:6>: z a
ITW ® 1/4" 1.1/4" 2" 4" DArE:10 08 17 n
TAPCON sauce N.T.S.
5
€ ELCO ® mvc,ar: JK m
ULTRACON aiK UP LFS 3
WOOD SCREW INSTALLATION NOTES: Ix
1.Maintain a minimum 5/8"edge distance,I"end distance,8.1"o.c:spacing of oruwwc Ho
FL—15781.15
:' wood screws to prevent the splitting of wood. °n
SHEEP OF E
R\Gients\Soft-Ute Permanent\A-Florida Product Approvals\FL-15781 Horizontal 511ders\C-Drawings\FL-157816TH ED(2017)\FL-15781.15Awg,5.2 '
Rp
I o cn'
H y o cq �
n
N
dd
2.25'
1--- 2.86'
1.211.
T
�(
m o S
y Q °n N y o.ob2"
I CD V
1 C�
Ls
1 25°
0.62"
I
0 0
� o
rl
� P
0.388, i� o
P
2 0 � LEE
0.089' � c
ao
m
A
0
o ---.... a.67' Q
i� aab• t
= 0.as°
N e,
w a
Svi-;t
a0.0911.
r 0.130 1.OS' No.43409
0.9G' — *
PRODUCT: Do—panto Pmpamd «� amim
I , g SOFT—LITE WINDOWS Lyndon F. Schmidt "+y ••' �GOR701•.••' ���
O P.E. No. 43409
00
V o Z O trrrraLlti�1
I� 1 1 25/18 REVISED PRESSURE RAi1NG5 LFS PART OR ASSEMBLY. GI3 BUtLDtNG CONSULTANTS, INC.
51
P.O, Box 230, VDlrlco, FL 33595
cn v NO PATE gY COMPONENTS
Phone No.: 813.659.9197
REVISIONS FBPE C.A. No. 9813
2i7t 7 R.W.BUII.piNO GON6ULTANIB INC.
BILL OF MATERIALS Z•``%%``"1it f'i'
ITEM a MATERIAL -4,0.- �'�
A 1X BUCK SG>=0.42 WOOD =°a`f' P.
B 2X BUCK SG>=0.42 WOOD
C 1/4"MAX.SHIM SPACE - �4
z rc om
D 1/4"X 2 3/4'PFH ELCO OR ITW CONCRETE SCREW STEEL %�' ��� 2 N
i �'•. . -
MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI
E CONCRETE ������ ����� i d;;d
301 OR HOLLOW BLOCK CONFORMING TO ASTM C90
F #8-15 X 2-1/7'TRUSS HEAD-SMS(1-3/8"MIN.EMBEDMENT) STEEL 0 N z
G 1/4"X 3 1/4"HWH ELCO OR ffW CONCRETE SCREW STEEL ?m m°
H 1/4"X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL \ o g S `o a
1 FRAME" PVC a N a m a a
3 WEEP HOLE COVER' PVC N s Wiz°
4 1 DSL FRAME FILLER* PVC 8
5 DSL HANDLE SASH' PVC o 3d
6 KEEPER RAIL' PVC 5/8"GLASS BITE 7/8"THICK
3 7 LOCK RAIL' PVC 1/89'ANNEALED
8 DSL MAIN SASH' PVC
9 GLAZING BEAD* PVC 3
10 DSL COVER• PVC z
F 11 ANTILIFTTRACK• PVC 3 �?
12 ROLLER SILL TRACK ALUM. o�
0 13 REINFORCEMENT(6065-T5ALUM) ALUM.' AIRSPACE
14 REINFORCEMENT(6065-T5 ALUM) ALUM. ao o Mz
1/8"ANNEALED N o <
15 REINFORCEMENT(6065-T5 ALUM) ALUM. o
19 ROLLER ASSM. - 1/2"GLAZING TAPE a a
20 LOCK - GT GLAz1NGDEfAn STEEL INTERCEPT SPACER y
21 LOCK KEEPER }
g m
22. #7 X 3/4"PFH TEK(LOCK)
26 #8 X 1"PPH TEK(KEEPER) SS
r 28 WEATHERSTRIP(187-270 TRI-FIN) -
9 'THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARETO BE PRODUCED BY Z
is EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS". z
j0
x n Ln
� a �
w
Q � u
a z
V m
Z cl
DATE:10108 17 z
SCALE: M.T.S. D
M.BY: JK m
g
cHLc.Br: LFS 3
DRAVANO NO.: D:
FL-15781.15 0
SHEET B OF16
6 N
V
o
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: 51a 0 /
Site: `� 7 l f J � C X t ks
Permit Type: A�,0V0y1r,6,6 S-w,�,A w s
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
W\e I IJ
61.1
This comment sheet shall be kept wit a permit an r-plans.
—Bui ding O c' Date Contractor and/or Homeowner
��\�� (Required when comments are present)