Loading...
HomeMy WebLinkAbout19-21382 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21382 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 21382 Address: 6611 PADEN WHEEL ST Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: SILVERADO Est. Value: Parcel Number: 05-26-21-0070-00400-0130 Improv. Cost: 8,321.00 OWNER INFORMATION Date Issued: 6/17/2019 Name: WADDICK, RICHARD & MENDE MECHELI. Total Fees: 127.50 Address: 6611 PADDEN WHEEL ST Amount Paid: 127.50 ZEPHYRHILLS FL 33542 Date Paid: 6/17/2019 Phone: 609-456-2323 Work Desc: CONSTRUCT SCRN ROOM 12 FT X 17 FT W/CONCRETE CONTRACTORS APPLICATION FEES RON L ALUMINUM BUILDING FEE 127.50 G (� Ins actions Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. -�7� &-- CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER INSTR#2019082400 OR BK UUUb PG 1 jbJ Page 1 of 1 05/15/2019 10:15 AM Rcpt:2054747 Rec: 10.00 IDS:0.00 IT:0.00 Paula S. O'Neil A.D., Tasco County CCerk&ComptroCCer I 'Ibis space for use by Clerk of the Circuit Court only. NOTICE OF COMMENCEMENT Permit Number: Tax Folio No.05-26-21-0070-00400-0130 The undersigned hereby gives notice that Improvements win be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the followinginformation is provided in the NOTICE OF COMMENCEMENT. I. Legal Description of property(street address required): 6611 PADEN WHEEL ST ZEPHYRHILLS FL 33541-2553 SILVERADO RANCH SUBDIVISION PHASES 2.3&4 PS 73 PG 059 BLOCK 4 LOT 13 .. . 2.' General description of improvements: So reGtf1 rOO(Y\ 3a. Owner Name: Mechell Mende Owner Address: 6611 PADEN WHEEL ST ZEPHYRHILLS FL 33541-2553 3b. Owner's interest in site: Na 3c. Fee Simple Title holder(of other than owner) nia. Y Address: 4. Contractor Name: Ronald Allen Address: 3122 McIntosh rd Dover FL 33627 Phone: 813-661-7255 5. Surety Name:N/A Amount of bond: Address: Phone: 6. Lender Name: N/A Contact: Address: Phone: 7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.13(lxa)7,Florida Statutes. Name: N/A Address: Phone Number: 8. In addition to himself Owner designates tkte fnk)nwin g petsonto receive a copy of)hc Lienoe.s t3otioe:as p16Vidca inSectioa 713.13(1)(b),Florida Statutes. Name: N/A Address: Phone Number. 9. Expiration date of Notice of Commencement(expiration date is one(1)year from date ofrecording unless a different date is specified). N/A .WARNING TOOWNEW.-ANY PAYMENTS 111119E BY-THE OWNER AVTER THE EVIRATIONOFTIIE'NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. lie PAULR.BULEY SignatureofO er rLessee,orOwneesort.esseesAuthocizedOfftcer/Director/PaMer/Manager Commission#GG032478 My Cbmmission ExpNes January 21,2021 Signatory's Tide/Office STATE OF FLORIDA COUNTY OF HILLSBOROUGH a The foregoing instrument was acknowledge before me Us day of rrAq 20 -1 by I�anf�l._ erd Q as for for�- PenionallyKnown OR Produced Identification Type of Identification Produced Signature-Notary Public Under penalties of perjury,I declare tltaLl+have read the foiego'utg aoA that the facts stated in it are true to the best of my knowledge and belief. Signal a of atural Persor n Sl mg Above W copy ofmry tlovd nos[Ec eeaAed m r6e t®e ofr¢a+dmi®offhis Naim of Commrneemm,) Updmed 29NOV2012 i �I cl�� � • ���° STATE OF FLORIDA, COUNTY OF PASCO . THIS IS TO CERTIFY THAT THE FOREGOING IS A o TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE . 4w WITNE fMY HAND AND OFFICIAL SEAL T I DAY OF 2 g7 �� PA LJLA O'NEIL,CL RK &C MPTROLLER . DEPUTY CLERK SKETCH-ONLY SEC. 05 . TWP.-16—S, RNG.--.91—E. PLOT PLAN NOT A BOUNDAibr SURVEY LOT 13, BLOCK 4 BEARING BASIS- SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SEX OF(15-26-21 BEING N 89"25*01- E PHASES 2. 3 ,& 4 THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS. [EASEMENTS AND RESTRICTIONS OF RECORD. PRELIMINARY DRAWING: ON LOT AREA CAII-CuLA-nom UNDERGROUND FOOTER, STEM WALL, AND THIS PL AN IS FOR PERMITTING PURPOSES LOT 719.63--SO. FT. UNDERGROUND UTILITIES ARE 140T LOCATED OR ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA FT. SHOWN. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY =--23 so. FT. GARAGE FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND LEGEND: COVERED.LANAJ 153 c o. Fr. Q NOTES TAKE PREFERENCE. ,—= PROPOSED DRAINAGE FLOW PATIO =_-N/ASO. FT. (00.00) = PROPOSED GRADE CONC. DRIVE =--A2§----SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND E-00.00 EXISTING GRADE A/C do CONE PAD =—!---SO. FM + PAGE INDICATES THAT PLAT IS IN PRIVATE SIDEWALK = 40 _--SO. FT. PRELIMINARY STAGE AND IS SUBJECT TO IMPERVIOUS =-AL-7. CHANGE AND/OR REVISION. NOTES: =-J�; o. FT. LOT GRADING TYPE- 8 SOD = IR17 So. FT. CERTAIN DATA SHOWN HEREON BASED ON PROPOSED PAD ELEVATION 10&7' ENGINEERING PLANS PROVIDED BY CLIENT. FRONT SET BACK = 20' OFF LOT AREA CALCULATIONS STRUCTURE TIES SHOWN HEREON DENOTES SIDE SET BACK = 7-5* RIGHT OF WAY = 1148-92 SO. FT. 'MEASUREMENT FROM FORM BOARDS/FOUNDATION REAR SETBACK - 15* DRIVE APRON --ASDSO. FL TO PROPERTY LINE. PUBLIC SIDEWALK n 325 sn, FT. SOD 473 stl, FT. = 10' U71UTY EASEMENT TOTALS PC(P)--\ AREA SQ. FT DRIVEWAY 976 SQ FT. SIDEWALK =--36-SS0. Fr SOD. =--IA29--Sp. FT. o LOT 14 BLOCK 4 0 89*57'13" E % 116.06' 3io.00 I# uj LLj O 77 ........ .. . ry 13 2o.fo! 0 615V� IE\1 t X--Z ...... Low. TRACT J w L Lo DRAINAGE AREA on > Nola 0 L w M 0 0 CL 0 uj z 29ZY ............. EL N 89-57'13" W 123.61' 12 LOT 12 0 BLOCK 4 DESCRIPnON: PROPOSED: LOT 13, BLOCK 4, MAP OR PLAT ENTITLED -SILVERADO LOWEST FLOOR ELEVATIONS: RANCH SUBDIVISION 'PHASES 2, 3 & 4", AS RECORDED IN LIVING AREA: 109.40* PLAT BOOK 73. PAGES .59 THROUGH 65, OF THE PUBLIC GARAGE AREA: RECORDS OF PASCO COUNTY, FLORIDA- ELEVATIONS REFERENCED TO NORTH AMERICAN VERTICAL I CURVE I RADIUSDATUM OF 1988. MEAN SEA -L CO --1 337.01 24"6' N 2073'0;E 47*4&N===� LEVEL= 00.00 FT. C160 337.01 Is - T APPARENT FLOOD HAZARD ZONE- -X- COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE 09/30/1992 :r• VT e City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 10 Z 1 t11�/j Date Received: 5Z1 7 Site: Permit Type: X 7 Sc yt n Yn L m c v 1 h Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall p with he permit and/or plans. JUI 1 '0 2019 uilding Official Date Contractor and/or Homeowner i� (Required when comments are present) i Ron L Aluminum j 3122 McIntosh Rd Dover FI�3 y22 Ofce:813 661-725- Fax: 81 3-661-2Q22 Ronla luminum Cad ao 1.com To whom it may concern, I Ronald Allen of Ron L Aluminum allow the following agents to pick up my permits of any papers that deal with Ron L Aluminum Nettie Allen Christine Allen Thank You Ronald Allen OLX- PAUL R.BULEY Ron L Aluminum ` Commission#GG032478 My CommissionExpTreS S. landw 21,zui1 j I 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received "l r 9 Phone Contact for Permitting 13 - S Owner's Name j, L� Owner Phone Number Owner's Address wit t Owner Phone Number u) ^' ( Owner Phone Number JOB ADDRESS l0 JQ&nS� Z �1 33 sy I LOT# SUBDIVISION PARCEL ID# ��0� 02 I — �� ' oOL(UQ — VI 3D (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = _ DEMOLISH INSTALL e REPAIR PROPOSED USE = SFR Q COMM ® OTHER I 19X 1 5C I r TYPE OF CONSTRUCTION = L-eeK--Q_FRAME = STEEL = DESCRIPTION OF WORK r _ , BUILDING SIZE SQ FOOTAGE HEIGHT BUILDING $ I VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL ` $ AMP SERVICE Q DUKE ENERGY Q W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION r =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED =1Y/ N FEE CURREN Address License# i MECHANICAL COMPANY SIGNATURE 4REGIED Y/ N FEE CURREN Y/N Address / License# OTHER - COMPANY L- 6 SIGNATURE REGISTERED Y/ N FEE CURREN Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,. Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1_dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract=required)',`-'-""• Reroofs if shingles Sewers.,;:.:... Service Upgrades A/C.::• :F.erices';(OIot/Survey/Footage)' iT�j�i:i•I roa Driveways-Not over Counter if on publiciiways,.needs +�. ,_y::a,sac:••' TICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions. ch may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any ilicable deed restrictions. LICENSED CONTRACTORS AND CONTRACTOWRESPONSIBILITIES: If the owner has hired a contractor or tractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the tractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation er state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the nded work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 9. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign ions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the tractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco nty. WSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildin:gs,l change of in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number.89-07 and 17, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of rlitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to iving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. ISTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I Fy that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's action Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the'applicant is someone -than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to er it to the"owner"prior to commencement. TRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work ie done in compliance with all applicable laws regulating construction, zoning and land development. Application is )y made to obtain a permit to do work and installation as indicated. I certify that no'wbrk or installation has nenced prior to issuance of a permit and that,all work will be performed to meet standards of all laws regulating truction, County and City codes, zoning regulations, and land development 'regulations in the jurisdiction. I also y that I understand that the regulations of other government agencies may apply to the intended work, and that it is -sponsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Weiland Areas and Environmentally:Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. .rstand that the following restrictions apply to the use of fill: Use of fill is not allowed in'Flood Zone W"unless expressly permitted. If the fill material is to be used in Flood Zone "A", it is understood that.a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone "A" in c'onnection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. If fill material is to be used in any area, I certify that use of such fill will not adversely affect-adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violat'ing the conditions of the building permit issued under the attached permit application, for lots less than, one (1) acre which are elevated by fill, an engineered drainage plan is required. the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in ridavit prior to commencing construction. I understand that a separate permit may be required for electrical work, ng, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A issued,shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or de any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter ig a correction of errors in plans, construction or,violations of any codes. Every permit issued shall become invalid the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by -mit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate )le cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. ING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR 6 TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT (OUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. N JURAT(F.S.IIL-03J OR AGE CONTRACTOR ed and sworn to(or affirmed)before me this S bs -to--Cor--affirWbedYbefore-med IS=­ .�ribeo and sworn I zz==�-" C8� ry- AV\oeJ-- —1 fil L4 Ve re personally known to me or has/have produce Who is/arelgrsonally known ffi-e-,Or---has/hava-.,produced----.'�, as identification. ----------- as identification. -Notary Public Notary Public Ion No. Commis on No. Votary typed,printed or stamped Name of Notary typed, 1*av" ,tar ELINE Bocts GG 2764S7 !K-Sotes De" flZ204 INSTR#20191 35682 OR BK 9954 PG 1009 Page 1 of 1 08/12/2019 10:17 AM Rcpt:2080320 Rec: 10.00 DS:0.00 IT:0.00 Nikki Alvarez-Sowles,Esq.,Pasco County Clerk&Comptroller,ad Interim This apace for use by Clerk of the Circuit Court only. NOTICE OF COMMENCEMENT Permit Number: Tax Folio No. 05-26-21-0080.00600-0310 The undersigned hereby gives notice that improvements will be made to certain real property,and in accordance with Section 713.13 of the Florida Statutes,the following information is provided In the NOTICE OF COMMENCEMENT. 1. Legal Description of property(street address required):6597 WAGON TRAIL_ST ZEPHYRHIU.S.FL 33541 SILVERADO RANCH SUBDIVISION PHASES 6.8&9A PB 75 PG 075 BLOCK 6 LOT 31 2. General description of improvements: _.WC A f 00M r"Ofe s• 3a. Owner Name: Bill&Susan Price Owner Address: 6597 WAGON TRAIL ST 2EPHYRHILLS,FL 33541 3b. Owner's interest in site:.nla 3c. Fee Simple Titleholder(of other than owner) We �,� �® Al 1 Address: 4. Contractor Name: Ronald Allen '�t Address: 3122 McIntosh rd Dover FL 33527 Phone: 813-061-7265 5. Surety Name: NIA Amount of bond: Address: Phone ` _•ti, `� � o °i 6. Lender Name: NIA Contact: —A Address: Phone: = -A ^f r 7. Person within the State of Florida designated by owner upon whom notices or other documents may be served as provided by Section 713.13(l)(a)7,Florida Statutes. Name: NIA Address: Phone Number: Q Z U 8. In addition to himself;Owner designates the following person to receive a copy of the Lienor's Notice as provided in Section C0 W LL W 713.13(1)ft Florida Statutes. ( z Z) O } 0 co F Name:__N/A Address: O - N Ir � 0 I¢U w f- a- Phone Number. E W 03 O 9. Expiration date of Notice of Commencement(expiration date is one(1)year from date of recording unless a different date is :Y- OL F- Q < O specified). WA z W 0 0 U U W WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMIENCEME:91T ARE . O CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1.SECTION 713.13,FLORIDA STATUTES,AND CAN RESULT IN YOUR LU PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE .4�l-F J Q U JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY 10 >- U OD Q BEFORE COMMENCING WORK OR RECORD URN CE OF COMMENCE Q Z O aim Signature of Owner or Lessee,or Owners or Lessee's Authorized Ofl5cer/Director/Panner/Manager D- O Of O P bZ17 `'73`6- 42-mot-0 0 1—� W P�1� Signatory's Title/Office = W E- - = � zSTATE OF FLORMA d!J k- F- O m COUNTY OF II.ISBOROUGIH The foregoing insrumeot was acknowledge before me this J-1, day of utd .20 14% by WAWLM "VriU ,as OWAM for Personally Known OR Produced Identification Type of Identification Produced Signature-Notary Public , Under eS pe' ,I declare that[have reEad o u�,and that the facts stated in it are true to the best of my knowledge and be Cj Sigastare of aUu Person Signing Above (A copy ofmy 600dmuAbemmhed anthetime ofteom I wer"NofiwofCommeocrmeoo Updated 29NOV2012 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS r= 1 Contractor/Homeowner: Date Received: Site: Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shalYbe kept with the permit and/or plans. Sep tQ9 Kalvin itzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Ron L Aluminum 3122 McIntosh Rd Dover FI 33527 Office:813-661-7255 Fax:813-661-2922 Email: Ronlaluminum@aol.com To 2ephyrhills Permit Office I Ronald Allen of Ron L Aluminum give the following agents to pickup and sign permit for my place of business. Nettie Allen Christine Allen Thanks Ronald Allen PAUL R.BULEY Commission#GG082478 My Commission Expires .lanuary 21,2021 C aN2Ea#12XI/4" f �v o OF BRACKET Post 4 is �`% I"x3" TAPCON OR E0UNALENT ► ► ,►►�+ MIN. TWO PER POST 9 o c � roofing system POST BwaCKET ONN ON foam core or metal roofing (alternate) " TO SLAB C install 2"x2 N" stitched 24 c.c. for first 3 ft agog from end (zone 2 pan roofing only) use #10x1.5" �Z ¢ 2x beam assemblyg 2x beam assembly 1%"0 through bolts with washers and vinyl nuts COMPOSITE ROOF CAP STRIP TO BE FASTENED WITH #10 X 1/4" SMS O 24" O.C. MAX. (TYP) E ,- 10 X (PANEL THICKNESS +1") S.M.S. W/ 1/4" X 1 1/2" S.S. NEOPR. WASHER 0 12" O.C. MAX. NOTES: V 1. FASTEN PANELS TO THE TOP ALUMINUM BEAM(S)WITH A MIN.OF FOUR#12X1" (pan roof to be fastened 0 4" o.c. max) LONG TEK SCREWS ACROSS THE PAN OR AT 12"CENTERS ALONG ALL BEARING POINTS ALONG THE PAN,OR PER MANUFACTURER RECOMMENDED METHODS ROOF PANEL ROOF PANEL I I < bD (USE MOST STRINGENT) f 2. THIS STRUCTURE IS NOT DESIGNED FOR SAFE HABITATION DURING STORM 1.5X2.125X0.045 - RECEIVING CHANNEL EVENTS ON BOTTOM SIDE OF BEAM. PLACE (3) 2"x3 2"x3" or 2"x4" #10X3/4" SMS ON EACH SIDE OF CHANNEL roar AND (3) INTO BOTTOM SIDE OF BEAM cps roof ^ - ?. O^ 2x beem aasemby ., +sC AL 4x4x0.125 post ROOF PANEL TO EDGE BEAM AND EDGE BEAM TO POST CONNECTION �N a>' C) z PANEL ROOF TO PANEL BEAM CONNECTION t0 E cc Z3 t saw BLit j"into �-In. CL w- stucco flrpsh apply}ribbon of geoseal R O\\ 74-po g m►Aoo '6'deep x 15'aide #8 x 'TEK SCREWS ON BOTH SIDES AT 8"O.C. concrete footer ■��■■ Existing Structure flashing(for tie Into masonry waft only) Y. PANEL 10' 05 coated rebar 3. 4' Or 1-1/2' I— ANCHOR TO BUILDING WOOD-#10X2"WOOD SCREWS AT 12'O.C. "MASONRY.}'X 1-112'CONCRETE SCREWS AT 24"O.C. s H "C"CHANNEL FOR COMPOSITE PANELS(ROOF TO HOST) N R1 N 2"x3" or 3"x2" �,�" $' I, 2"x2" 2"x2" c •o.�N/� ' O �• apiz (1) #10x TEK EA. SIDE TOC$ . lt c hinge pointsRLH + RADIUSS FASTEN RADIUS SNAP TO RLH '�'� Ox o U 2"x2"x.0.125" ANGLE EACH chair rail air ra chair SIDE OF COLUMN FASTENED y . '`` X 2"x2" WITH (2) 25" A 1"x2" c ch il N 1" „ 1"x2" (EACH ANGLE/EACH SIDE) ►�� �'' rail ;li[Door Detail — Option 1 1x2 Door Detail — Option 2 > Centered between Columns Door Adjacent to Column 1 (MIN.)•�•� '�, o~W� � R � Door Notes: - $q11 � 1:Number of Hinges: min. 3 points 2— '4 •. J"x1-4" 2.Hinge Locations: MIN. MASONRY ANCHOR TO 0` 8 su " ': .,_:.` : (MIN.) FASTEN 2" WIDE 1x2x ANGLE TO SLAB. � � I2.1.Top & Bottom — 8" to 18" from end of door a o z 2.2.Remaining to be evenly spaced between Top and Bottom hinges MIN. (2) #10x " ON BACK OF COLUMN 2.3.Hinges can be installed on either side of door, field locate a 3.Fasteners: d d • 3.1.#10x " screws d d v 3.2.Min. 3 each to attach hinges to structure and door 4.Door to swing ourward unless noted otherwise 5.Left or Right swing does not alter structural integrity of cage or door ,G a PURLIN 2x3 SPECIAL 0 x3 TAPCON TAPCON OR EQUIVALENT Q+ ANCHOR SPACING: h • ONE ON EACH SIDE OF COLUMN MAX. 6" FROM COLUMN fi SPACED EVERY 24" O.C. BETWEEN COLUMNS ; a� 2"x2"x.0.125" ANGLE EACH SIDE OF COLUMN FASTENED COLUMN CONNECTION DETAIL — elevation •� • ,Qy WITH (2) #1oxE" SMS BEAM SUPPORTING COLUMN -;j'. ti•,_.j• (EACH ANGLE/EACH SIDE) 2"x2"x.0.125" ANGLE EACH Length of Anchor: SIDE OF COLUMN FASTENED (base channel) (embedment) (paver) WITH (2) #10x " SMS B.C. Thickness + 2" + Paver Thickness 3/8"X_" TAPCON OR Equivalent (EACH ANGLE/EACH SIDE) (effective 2x5 column) THRU ANGLE AND BASE CHANNEL EDGE OF SLAB INTO CONCRETE SLAB Jk 3N RLH + RADIUS SNAP (1) #1O TEK EA. SIDE TO I / I W LL FASTEN RADIUS SNAP TO RLH .e 'er (TOP AND BOTTOM) ® �' = 1" (MIN.) �•• %�::�:.:`; (1) #10x TEK EA. SIDE TO .: 2"x2"x.0.125" ANGLE EACH O `>+ U) zxzx.as SNAP FASTEN RADIUS SNAP TO RLH SIDE OF COLUMN FASTENED (TOP AND BOTTOM) 0a a (MIN.) WITH (2) #10xJ" SMS (2) #10x TEK TO FASTEN-< (EACH ANGLE/EACH SIDE) 2x2x.0.125 SMS ANGLE TO COLUMN P —3/8"X_" TAPCON OR Equivalent V m p ® THRU ANGLE INTO CONCRETE SLAB 4' Jc� not required for lanai screen—in La d d O\ d rnaxoa SNAP "x3" TAPCON OR EQUIVALENT E COLUMN CONNECTION DETAIL — elevation COLUMN CONNECTION DETAIL — plan view T PST PURLIN SUPPORTING COLUMN o MVJ ,,,f1I II______ a 0 LINTEL/HEADER na ft j Q a . Q oza m ANCHOR TO BUN.DING d 'g a____ WOOD - #1OX3" WOOD SCREWS 0 12" O.C. (4) #10x2" SMS thru 1x2 MASONRY - ;}"4X2.5" CONC SCREWS O 24' O.C. base channel into internal screw bosses of column (4) #10x2" SMS thru 1x2 v e N base channel into internal screw bosses of chair rail 1C�1 aq ANCHOR TO BUILDING • WOOD - #1Ox3' WOOD SCREWS 0 12" O.C. • MASONRY - }'4X2.5" CONC SCREWS 0 24" O.C. (4) #10x2" SMS thru 1x2 base channel into internal screw bosses of column V.... ANCHOR TO BUILDING =Cl) • WOOD - #10x3' WOOD SCREWS 0 12' O.C. d1 J • MASONRY - 4"4X2.5" CONC SCREWS 0 24" O.C. 4 -0 d U. S N MIN: . d 5 SLAB/FOOTER = w Ram � TYPICAL 1 "x2" CONNECTION (HOST/FOUNDAtION) v� N .�co s H E T LNI N o a Ld t�3ac S 4 Each #10x2 SMS into O O JS (min) '• �'•C• I internal screw bosses cT \ ® __Mov•it SMB 0 D_ r w o m SMB 4 Each #10x2 SUS into internal screw bosses SMB #12x2 teks through beam into insert. typ as shown �^ 5 E /'\ Lu eC trim 'wings' off clip so that �., ~ sides are flush (only when used end view i s in peak on gable end) ® TOP VIEW 4 Eoch;10x2 $16 into ® O O 45 max) p 1Memal. . O O s� O ® � SIDE VIEW OO OO vw SIDE VIEW FRONT VIEW 3N screws will be concealed by SMB cc y trim 'wings' off clip so that sides T C are flush S� • f 1;90 OO 0 � ® I ® � 0 � SIDE VIEW #12x2 tales through bm. Into art. to a. shown I O end gable E T RON L CLIPS detail RU 0 ALTERNATE: (4) #10x2 SMS thru •``�" * Purlins: (4) #10x SMS beam or post into internal screw B • •o••.Ni� (2 each side) bosses of purlin or chairroil b.fp: •• S- V coop Chairrail: BEAM J (2) #10x " SMS OR �0 (one each side) ,� ° w• 8 ac : POST Q��� Q Q = y oQ ® I •••�F �` 1"x2— "x2" Aluminum clip i Chairrail or Purlin 2X_ SMB �e G oQ y `` attached to beam or post ,�� � with (2) #10x " SMS !� ��'Q BCR To TOP PLATE � � ° O oQ (5) iloxs/4 sly WRY CHAIRRAIL/PURLIN CONNECTION hx I =' g s TO POST BEAM O ® (5)�, /4 Hug f N i≤ = n, aW>-•-aim BI TO cOL,MN (2) TOP VIEW BR TO ROOF BEAU #10X3/4 $AS ON (4)�H SSE BEAN EACH SIDE OF COLUMN CJ 2" 0.090" o fi G biJ FIwsHEO cxtAoe HEW Co7TIIIIIIL J� + •"� € �., IN. O� fl fl G N a pC T r • a � g. � FRONT VIEW av SIDE VIEW NOTES: 0.185• 1. Bracket is designed to comply with th Aluminum e' + Design Manual 2015 and ASM 35 V 2. See plan sheet 1 for allow requirements. REINFORCING STEEL OPTIONS: 1.875" �+ • 1x #5 BAR (shown) or 2x I3 RON-L BCR BRACKET SCREEN ROOM/SOLID ROOF STRUCTURE •GUTTER BRACKET AT BEAM POINT ANCHOR TO BUILDING •WOOD - #1OX3" WOOD SCREWS 0 12 O.C. •MASONRY — 1"eX1.5" CONC SCREWS 0 24" O.C. . o. f (4) #10X" TEK each side / / beam "X3" WEL J DED STEEL EYEBOLT 'D d ,s / T11RU PREPUNCHED SLOT THRU m LL (3) #10x3" SMS IN TRIANGULAR ALUMINUM 2X_ BEAM / �T / BRACEEH HS NDOOF pt�'e 5 MOUNTING BRACKET L . 61 (1) j" NUT W/T"STEEL WASH �7'•� �a Q F GUTTER r N tU ry ALUMINUM PERIMETER FRAME " c T m e 7 NU7 W/"SfEEI WASH V� 1" EE ec a• STAINLESS STEEL (4) tOX" TEK each side o� BRAIDED WIRE (1850 LB)p �e •'b a (3) #10x3" SMS IN 12` - 16" LENGTHS W F $ ti+ EACH END OF 2X_ GUTTER FACE BEAMS IF MIN. Z 9 V BRACE AS SHOWN edge beam CLEAR HT. OF 7'-0" IS MET. l r., • DOUBLE ALUMINUM o I-i► o 0 CRIMPS (TYP.) ______ CARRIER BEAM - GUTTER FACE BEAM - HOST CONNECTIONS . ~j = CORNER BRACE ^• x.s: ,,. s . TRIANGULAR BRACKET DESIGN FOR CABLE TIE BCR o NOTES: 2"x2"x:O46" HOLLOW 2"x3"x.O46" HOLLOW DESIGN CONFORMS TO THE FOLLOWING REQUIREMENTS: �' %4I ,1. spans based upon calculations performed by engineer. > , WEB THICKNESS: 0.046" WEB THICKNESS: 0.046" Florida Building Code 6th Edition-Building&Residential(2017) �%' , J/`/ 2. do not exceed spacing between 'colums (dims shown are ,, FLANGE THICKNESS: 0.046" FLANGE THICKNESS: 0.046" •• TABLE 1604.5 B ,.�' o •., AREA: 0.4704 SQ.IN. AREA: 0.5976 SQ.IN. o.c.) without written approval from engineer, additional o ' ° Sg columns can be added or spacing/spans reduced with no ••• Screened Enclosures-Risk Category I •'" MOMENT OF INTERIA: MOMENT OF INTERIA: ••• Sun-Roans/Acrylic Enclosures-Risk Category II «. p!'•' a adverse affect. —Ixx = 0.2565 in�4 —Ixx 0.6873 in�4 •• Figures 1609.3(3)-140 mph windzone(3 second gust) R >ld 3. beam and column sizes can be increased in size with no .. 1609.4.2&.3-Exposure Cat —Iyy = 0.3069 in-4 —Iyy = 0.4202 in"4 adverse affect to structure, sizes shown are minimums. 2002.3.1-Extruded Aluminum�thave aminimum wall thickness of 0.040" •'SECTION OF MODULUS: SECTION OF MODULUS: 4. columns and beams should be evenly spaced where .. Table 2002.4 ( • —Sxx = 0.2663 in"3 —Sxx = 0.5041 in"3 practical. B.GS� —Syy = 0.3069 in"3 —Syy = 0.4228 in"3 5. contractor is allowed to make minor ••• Structure Loading Pressure(Exposure C): field adjustments to adjustments •••• Horizontal(winwardfleewani)=38 PSF/29 PSF RADIUS OF GYRATION: RADIUS OF GYRATION: account for field conditions. •, —rxx = O7385 in —rxx = •••• Vertical(screen/solid)=11 PSF/32 PSF •• 1.0725 in 6. frame is not designed or intended to be used as safe 0 • Interior (calculated psf Pressure=t4.4dated ASCE 7 —ryy = 0.8077 in —ryy = 0.8385 in habitation during a storm event. ) ,,,,�, ALLOWABLE Fy: 16.0 kip ALLOWABLE Fy: 17.2 kip Concrete to meet requirements of Chapter 4 of FBC-R and Table R402.2 TRESSPASS NOTE: Structure designed for use with 20x20 max mesh density Mmax = 3.92 kip—in Mmax = 7.16 kip—inLL • 2002.4-Any 1 ft length of vertical memeber is designed fora 300#vertical load.Owner and/or non—construction �9 i9n Any 1 ft length of horizontal memeber is designed for a 200#vertical bad. 2"x5"x.O5O" SMR and/or non—jurisdiction related F o WEB THICKNESS: 0.050" personnel are not allowed in the • Contractor Is allowed to use aluminum alloy 6005T5 and 6061T6 Z R FLANGE THICKNESS 0.1310" construction zone until a certificate I o - AREA: 0.9174 SQ.IN. of completion/occupancy has been J Z . MOMENT OF INTERIA issued by the jurisdiction. tQ1 O —Ixx = 3.6435 in"4 a _ —Iyy = 0.5916 in-4 SECTION OF MODULUS: -Sxx = 1.5103 in3 v C —Syy = 0.5917 in-3 RADIUS OF GYRATION: —rxx = 1.9929 in —ryy = 0.8030 in ALLOWABLE Fy: 9.2 kip •4 E Mmax = 13.89 kip—in ' a a s~ 1"x2" 1" X C#1 M N _ X X 2"x5" composite roaring 2"x5" I U N fV fV I __ _ __ I 17' 2"x3" 2"x3" 2"x3" CO WQwS N Z COMPOSITE ROOF INFORMATION: J m _ rio,k L D L IMP 1. foam core panels with aluminum skin. Q F q UJ �YW/ Rj5! ej Ti, 2. fasten eps panels to the top aluminum beams)with#10x4"long tek Q? O J`rTEC/�,0 rTjC C JN(i'C F L� screws at 12"centers along all bearing edges. ( S, OF ��E �F, /�/N i C 3. minimum roof pitch to be J"rise/fall per foot of run 2"x2" 2"x2" 2"x2" ZFPyy •/�`S "a 0 4. contractor may substitute structural and functional equivalent materials. 1"x2" 1"x2" 1"x2" 5. product approval information: �`� r N 5.1. manufacturer elite aluminum corporation 5'-8" C l� V to 5.2. category: roofing �T j' v�f� '4�5.3. subcategory: metal roofing 5.4. II approval no.: f17561-r4 ) s, `. v/V 5.5. hvhz use: approved(non-living) 5.6. non hvhz use: approved `'y/'. MAXIMUM 3" PANEL SPAN: * 1# CORE W/O.O24 SKIN = 13.17 FT SHEET Page — D ription H { 1 LAYOUT, NOTES T 01 2 to end DETAILS NOTES: ,r r r r "x.046" HOLLOW 2"x3"x.O46". O l OW 1. spans based upon calculations performed by engineer. DESIGN CONFORMS TO THE FOLLOWING REQUIREMENTS: WEB THICKNESS: 0.046" WEB THICKNESS: 0.046" g . Florida Building do not exceed spacing between colums (dims Shown are m9 Code 6th Edition-Building&'Residential(2017) w > ?/� FLANGE THICKNESS: 0.046" FLANGE THICKNESS: 0.046" •• TABLE 1604.5 / o.c.) without written approval from engineer. additional ono •. t� AREA: 0.4704 SQ.IN. AREA: 0.5976 SQ.IN. ••• Screened Enclosures-Risk Category 1 ' .� 0� • columns can be added or spacing/spans reduced with no Sun-Rooms/Acrylic MOMENT OF INTERIA: MOMENT OF INTERIA: ••• Enclosures-Risk Category IIj —Ixx = 0.2565 in"4 —Ixx = 0.6873 in '4 adverse affect. Figures 1609.3(3)-140 3. beam and column sizes can be increased in size with no •• mph in one second 9 ) q —lyy = 0.3069 in�4 —lyy = 0.4202 in�4 adverse affect to structure, sizes shown are minimums. " 1609.4.2&.3-Exposure Category C(see pressures below) Lri N W SECTION OF MODULUS: SECTION OF MODULUS: 4. columns and beams should be evenly spaced where •' 00002.2002.4 Extruded Annum to have a minimum wail thickness of 0.040; ^O —Sxx = 0.2663 in '3 —Sxx = 0.5041 1n '3 practical. —Syy = 0.3069 in-3 -Syy = 0.4228 in^3 5. contractor is allowed to make minor field adjustments to "• Structure Loading Pressure(Exposure C): RADIUS OF GYRATION: RADIUS OF GYRATION: account for field conditions. "" Horizontal(winward/eeward)=38 PSF/29 PSF —rxx = 07385 in —rxx = 1.0725 in 6. frame is not designed or intended to be used tis safe Vertical(screen/solid)=11 PSF/32 PSF —ryy = 0.8077 in —ryy = 0.8385, in habitation during a storm event. .t • Interior Pressure=±4.4 psf(calculated per ASCE 7) • ALLOWABLE Fy: 16.0 kip ALLOWABLE Fy: 17.2 kip • AConcrete to meet requirements of Chapter4 of FBC-R and Table R402.2 `" Mmax = 3.92 kip—in ,•i'' Mmax = 7.16 TRESSPASS NOTE: ( . Structure designed forvse with 20x20 max mesh density Owner and/or non—construction '. • 2002.4-Any 1 ft length of vertical rnerr►eber.is ned fora 300 vertical o Z 2"x5"x.O5O" SMB 2"x8"x.072" SMB and/or non—jurisdiction related Any 1 I length of horizontal memeber is tiesgned for a 200#vertical load. - 11I FT1 WEB THICKNESS: 0.050" WEB THICKNESS: 0.072" personnel are not allowed in the • Contractor is allowed to use aluminum alloy 6005T5 and 6061 T6 = - cQ FLANGE THICKNESS: 0.1310" FLANGE THICKNESS: 0.2390" construction zone until a certificate 15 g AREA: 0.9174 SQ.IN. AREA: 1.8473 SQ.IN. of completion/occupancy has been MOMENT OF INTERIA: MOMENT OF INTERIA: issued by the jurisdiction. - -Ixx = 3.6435 in'4 —Ixx = 16.5567 in4 —Iyy = 0.5916 in-4 —lyy = 1.2148 in-4 SECTION OF MODULUS: SECTION OF MODULUS: -Sxx = 1.5103 in3 —Sxx = 4.1409 ir(3 -Syy = 0.5917 in-3 -Syy = 1.2148 in'3 RADIUS.OF GYRATION: RADIUS OF GYRATION —rxx = 1.9929 in —rxx = 2.9938 in ryy = 0.8030 in —ryy = 0.8109 in ALLOWABLE Fy: 9.2 kip ALLOWABLE Fy: 16.1 kip Mmax = 13.89 kip-in Mmax = 66.67 kip—in 2"x 1O"x.O92" SMB WEB THICKNESS: 0.092" 1"x2" 1" " .� .- FLANGE THICKNESS: 0.3890" 1 T _ 'AREA: 3.0125 SQ.IN. u MOMENT OF INTERIA: N N _ " N N N —Ixx = 42.282 4 2"x5" N x screen roofing •N- 2"x5"—Iyy = 1.9264 in4 SECTION OF MODULUS: -Sxx = 8.4618 in3 x M " —Syy = 1.9264 in^3 ____ _____RADIUS OF GYRATION: �" N composite roofing iV iV c —rxx = 3.7464 in —ryy = 0.7997 in ALLOWABLE Fy: 17.4 kip 17' 8' Mmax = 147.49 kip—in T 2"X2" 2"x2" 2"x3" Y LING LG� Y Z COMPOSITE ROOF INFORMATION: —1 1. foam core panels with aluminum skin. j( x x x " CQ0. PLN0 [A� w, C IL 2. fasten eps panels to the top aluminum beam(s)with#10x4"long tek N C' 6 screws at 12"centers along all bearing edges. �►1 M`�"' P Gre L 3. minimum roof pitch to be J"rise/fall per foot of run 2"x2" 2"x2" 2"x2" TME ES V 4. contractor may substitute structural and functional equivalent materials. 1"x2" 1"x2" 1"x2" � Cc tl d 5. product approval information: r y 5.1.2 macategory: elite aluminum corporation 8,-6" 8,_6" 1 8' IV N 5.2. category: roofing 17 2 5.3. subcategory: metal roofing C O 5.4. II approval no.: 117561-r4 • 5.5. hvhz use: approved(non living) 5.6. non hvhz use: approved MAXIMUM 3" PANEL SPAN: • * 1j/ CORE W/O.O24 SKIN = 13.17 FT SD EX: Page — Description T0T... 1 LAYOUT, NOTES 01 2 to end DETAILS •