Loading...
HomeMy WebLinkAbout19-21385 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21385 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:21385 Issued: 6/17/2019 Address: 7006 SILVERADO RANCH BLVD Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 14,897.69 Subdivision: SILVERADO Amount Paid: 14,897.69 Date Paid: 6/17/2019 Parcel Number: 05-26-21-0100-00700-0120 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA, FL 33637 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT APPLICATION FEES PLUMBING FEE 206.25 ELECTRICAL FEE 309.38 MECHANICAL-FEE 144.38 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,477.49 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 coo Inspections Re ui- F OTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Q.. ft,011 l..O.�fl,.ay� t., City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ZX D�p��— , n Date Received: ,6—R �— Site: Permit Type: �'l i'1q �� c 2-3&2 S Approved Who comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ t This comment sheet sh 1-b6 kept with the permit and/or plans. JUN 0 6. 2019 -. Kalvin itzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2019098490 OR BK 9920 PG2977 Page I of I 06/11/2019 12:29 PM kept:2062486 Rec:10.00 DS:0.00 IT:0.00 Paula S. O'XeiC Ph.D., Pasco County Ccerre&Comytroffier Permit No. Parcel ID No INC;-7L I -CAM NOTICE OF COMMENCEMENT state of Florida County Of IRESCO- THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following Information is provided In this Notice of Commencement 1. Description of Property: Pared Identification No. + rn& Street Address: 3tD&O jjxrnA(% T. cja JalevnkA V 2. General Descriptlonof improvement New Single FamilyResidence 3. Owner Information or Lessee information if the Lessee contracted for the improvement: D.R. Hortdn. Inc Name 12602 TP-Itannm DriyA Tames 33637 El Address city State Interest in Property: Fee SOMPIO Name of Fee Simple Titleholder. (if different from Owner listed above) Address 4. Contractor D.R. Halton, Inc city State Name ' 12602 Telecom Drive, Tampa 33637 _EL_ Address city State Contractor's Telephone No.: 5. surety- N/A Name Address City State Amount of Bond: NIA Telephone No.: a. Lender N/A__ Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive - Tampa 33637, FL Address CRY State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates N/A Of to receive a copy of the Usnor's Notice as provided in Section 713.13(4)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. S. Expiration date of Notes of Commencement(the wpiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHIAPTSR7113, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. -A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signature ofOwner or Lessee,or Owners or Lessee's Authorized Officer[DIrector/PartneriManager AssistantSecretandD.R. Horton. Inc Signatory's Title(Offloe The foregoing Instrument was acknowledged before me this Z_J�_day of LJ40%, 20#by_106_& q:�. . — - as &iMstant Secmtary .(type of authority,e.g.,officer,trustee,attorney in fact)for D.E. Horton. Inc (name of party on behalf of whom instrument was executed). Personally Known R OR Produced Identification 0 Notary Signature'_ 1-aM.•+�- nc_,� Type of IdenlifficatIon Produced Name(Print) DANA ANNE NAGHTIN r e, Notary Public-State of]Rorida jor Commission #GG 010660 My Comm.Expires Jul 12.2020 wpdataibcstnoUr.ecommencemnLpeDS3048 D.R. Horton-7006 Silverado Ranch Blvd.-2,362 sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 1,375.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,477.50 ELECTRICAL: $ 309.38 PLUMBING: $ 206.25 MECHANICAL: $ 144.38 SUB-TOTAL $ 2,137.50 TOTAL $ 2,137.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,690.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,897.69 PASCO COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name Control#' County Parcel No. SubDiv:0 100—po7oo-0/2- Address/Location -70060 zvc) Classification[Type of Use TRANSPORTATION IMPACT FEE Rate: Sq-FtUnIt: Exempt []Yes [] No How Determined Impact Fee Amount $. 34-32,& Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ -71805, 2,8 (057) Mobile Home (058) Other Residential (123) Collection Fee Exempt n Yes F] No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt F] Yes n No How Determined Total Amountc__, � RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By Lj NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED.OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt ot-a'dopy of this form,placing the building permit owner on notice of this assessment and the conditions,of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY 4 Single Family Dwelling Plan Review Comments 1. F.F.E.. shall.be a minimum of 8" above the road elevation an_ d an engineered site plan. 2: Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4: Tie'in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit All 4 sides of driveway thM the sidewalk shall have expansion material. 6. All setbacks shall be met. 7: All property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.requirements shall be rnet: 9-. No electric,.plumbing; mechanical, or framing shall be covered without an-inspection and approval first. M All Garages,shall comply with section R302:6 of the F.B.-C. (Fire Separation). 11. Appliances shall not be installed in a location where subject Win damage unless . protected by.approved barriers. M303;4 of the F.B.0 12. Water heaters-shall comply with section P607.3 of the F.B C.- 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308:1 146 Return air in all bedrooms. F.B.C. M1620.4 1.5. Smoke detectors are to be- installed in accordance with R313:1-of the F.B.C. 16.All glazing requirements are to be in accordance with R308.4 of the F.B.-C: 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. ``Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 10. Combination-type AM breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will:be required in new construction that_uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. 25: R403.5.3Hot water'pipe insulation Insulation-for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the following: Piping-1.inch (19.1 mm)and larger in nominal diameter. Piping.serving more than.one dwelling unit. Piping located outside the conditioned space. Piping from the:water heater to.a distribution manifold. ,Piping.located under a floor slab. Buried in piping.. Supply and return piping in recirculation'systems other than demand recirculation systems. 25. Blower door test shall be provided before C.Oe 26. A copy of the enemy cacls shall be.with permit at all times. 2 Z.Copy of final insulation-report shall be provided with permit before rinaL 28. No.'fence,pool onscreen enclosure .is issued with:this permit' F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W.-Right of Way A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code(2016) D.R. Horton-7006 Silverado Ranch Blvd:2 362 s ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 1,375.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,477.50 ELECTRICAL: $ 309.38 PLUMBING: $ 206.25 MECHANICAL: $ 144.38 SUB-TOTAL $ 2,137.50 TOTAL $ 2,137.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,690.85 PARK IMPACT FEES 1 $ 769.56 SIF'S: $ 7,728.00 100.0% $ 7,728.00 1.0% $ 77.28 TOTAL: $ 7,805.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,897.69 u ' City of Zeprytilis Permit Application Fax-813-760-0021 Building Department Date Received Phone Contact for Permitting 7'T""rT9f'i—I T J <= Owner Phone Number Owner's Name t c ,-. Owner's Address PC.O �� _` '" ' Yr T���'"}� .Owner Phone Number Fes Simple Titleholder.Name r» Owner Phone Number Fee Simple Titleholder Ad dress JOB ADDRESS (o LOT# I Z SUBDIVISION J�F i a !" �C� PARCEL iD# t: "" 6 (OBTAINED FROM PROPERTY TAX NOTICE) ; WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE ©"_ SFR Q COMM OTHER TYPE OF CONSTRUCTION • �� BLOCK 0 FRAME STEEL DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE `�3`��+�+ HEIGHT r`r-rR-t-rt-r'a"r"r7-4 a a rrx-r-r^r's-r�t�l-m-'-t'-e-r"r'r�-n"1-t�e'-e"rr'tt-�->n-e�-ras-r>z-r-r-n->a-r'9- j =BUILDING $ VALUATION OF TOTAL CONSTRUCTION " ELECTRICAL oo AMP SERVICE PROGRESS ENERGY W.R.E.C. =PLUMBING $ =MECHANICAL $ �r �� VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO i !x_..g o -4-4-g-C•-C-1-1'-6-4--0--i-�--a-�-t-1{--0-i-B-�i-�:-g-�-i-F-�r-1-C-+r7-3-;�'�8-�-:-�-E'er:-�-C-'•-C"-i�'-&--6-G�' a-9-�'-`i-{f-kv'-I�i�in°��-@�'6-6-1..t.. BUILDER j � ' _ r COMPANY SIGNATURE REGISTERED Y/ N FEE CURRER Y/N Address I 4� 4',? l=/r-<ea License# �" I .,ELECTRICIAN �.,./��- COMPANY �1n,c'J'0J�N"3 SIGNATURE d 1 REGISTERED Y/ N FEE CURRER Y/N Address 6�'"�-: �:���=�A"��r�`" r err �.�, License# F.,;-ci z X,�/410 I .. 4 PLUMBER _ COMPANY F' �� " ,f` - .,1i 4' A1' ;r� , SIGNATURE REGISTERED Y/ N FEE CURRER,^ Y/�N/ Address' '� a ram. *' T tlr l �� ,1 License# MECHANICAL COMPANY P'"6��i€` L• � ° > " - SIGNATURE � -E^_�-��� "' "_" —REGISTERED YI/ N FEE CURRER Y/N Address J�w } �.� ft°JS a a1� 'fir. C "d: 4 License# '1-4C 0,F 56� OTHER r ... - -- -- COMPANYd )I �r SIGNATURE ^� ,�_ 't REGISTERED Y J N FEE CURRER Y/N Address f '`�f /�� License# tlltttlll' IllttillItltIllllillitiiltllllllll111lI11l1l1@@@ ! @1111911 RESIDENTIAL Attach (2)Plot Plan:,; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten (10)v::orking days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt,Fence installed, Sanitary Facilities& 1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms,R-O-W Permit for new-construction. Minimum ten (10)i )rking days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities 7,1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of E-igineered Plans. '."***PROPERTY•SI.!,1VEY required for all NEW construction. .-0...f..[-8-i..l-d--l-E-1--i-i-d-.8-t-i=.i...':-�-�J..I-6-1-i-tS-.@-@--1.-6-b.d..8-.1-t-B-l.-li.-@.-➢-t-E...t-�i-i-1-l.-E..E...8..9�.L..!-&-1..Cc6.-@..�...&..Y�.@-9-6P.�8..�.. Directions: Fill out application completely. Owner�Contractor sign back Of 0plication,notarized If over$2500,a Notice of Coin n-.vncement Is required. (A/C upgrades over$7500) ** Agent(for the•contractor)or Pow(r of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs•if shingles Sewers :,ervice Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Not over Counter if on public rcadways..rieeds ROW G' _', ' . . NOTICE 0F DEED RESTRICTIONS: The undersigned understands that this permit ' be subject to "deed" restrictions", which be reo�iot�ethan County naguladone. The undersigned aaaurnasrea compliancennibU�yfnr ' wilh any applicable deed restrictions, UNLICENSED CONTRACTORS AND CONTRACTOR [ ESPONSlB/L�|ES� If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and-local regulations. �1he contractor is not-licensed as required by |aw, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended.contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County' Building Inspection Division—Licensing Section at 2T-O47- ' 8009. Furthermore, if the ovvn8[ has hired e contractor or u}ntraotom, he is advised to have the contractor(s) sign portions of the "contractor B(ock" of this application for which they will be responsible. |fyou. ao the owner sign — ' th� contractor, that may ba an indication that he is not properly licensed and is not entitled to permitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, Or expansion of existing bUi|d|nga, as specified in Pasco County Ordinance number 89-07 and 90'07' as amended. The undersigned also Undanatanda, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees, must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve 8 certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pmsc&County Water/Sewer Impact fees are due,they must bepaid priorto permit issuance |n accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as mrnaodecB: If valuation of Work is $2.500.00 or more. \ certify that (, the apphcant, have been provided with a nopy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgricu|ture.und Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"oxvne/' prior tocommencement. CONTRACTOR`S/{]VVNER`S AFFIDAVIT: | certify that all the information in this' application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |avva regulating oonstruction. County and City codes,' zoning regulations, and land development regulations ' in the jurisdiction. | also certify un derstand my responsibility to identify what actions | must take tobeincompliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Boyheads. VVe�and Areas and Environmentally Gnnsh|vo Lands,VVato0��astowaterTroatn\ent. ' Southwest Florida VVsdmr Management Diothot-Na||m, Cypress. Bayheada, Wetland Areas` Altering Watercourses. ' Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' Department of Health & Rehabilitative Services/Environmental Health Unh-WeUm, Wastewater Treatment,� Septic Tanks. ' US-Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authnrhy-Runweym. | understand that the following restrictions apply to the use offill: - Use of fill ia not allowed in Flood Zone"V" unless expressly permitted. ' If the fill nne¢eha| is to be used in Flood Zone "A'. it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional eng\neei licensed by the State ofFlorida. � - If the fill material is to be used in Flood Zone "A" in connection with o permitted building using stem wall oVnctruo�on, ) cerdfv that fU|��U| be used only tofU|the area within the stem wall. ' M fill material in to be used in any area. | certify that use of such fill will not adversely affect adjacent . properties, If use of fill ia found to adversely affect adjacent properties, the ownernlaybnnked for vio|a�ng the nondibonmufthe building permit issued under the attached perrV|tappUua�on, for lots less than one /1\ acre which are elevated by fill, an engineered drainage plan |arequ\red. if | amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction'. | understand that a separate permit may be.required for electrical work' plumbing, eigna, xveU|o' pools, air conditioning, gas' or other installations not apenU5maUy included in the application. A permit issued shall be construed to be a license to proceed vv|th-thevvnrk and not as authority to v|o|o1o' ounce|, a|tnr, or set aside any provisions of the technical codes, nor shall issuanceof a permit prevent the Building Official from thereafter requiring aoornentipnof errors-in plans, construction or violations of any codes. Every pernnbissued ohaUbeconne \nveUd unless-the work authorized by such permit is commenced within six months of permit isaue000, or if work authorized by the permit is*suspended or abandoned for a period,of six (6) months after the time the Work is commenced. An extension may be requested. in vvriting, from the Building Official for a period not to exceed ninety (QO) daye' end will demonstrate � justifiable cause for the extension. |f work ceases for ninety (QO) consecutive days.the job in considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. lF YOU INTEND TO OBTAIN FlNANC)0G, CONSO[TWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. ' L~^D"^"""' (F.". ''' ""v OWNER OR AGENT Subscribed and sworn to(or a�nn � Subscribed and sworn to(or affirmed)before me this by by Who—is/are personally known~''e= ' a= '"=ep=""^"" Who is/are veruvxulyknown mmenrhas/have as identificoon. as identification. . J3N ary Public Notary Public ` 0M I on No v ` Commission_ _--_--' typed,,''--_ stampedz'A:-4­4 State of Florida-Notary Public 'W' my Commission Expires July ' 2022 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 12, BLOCK 7, SILVERADO RANCH SUBDIVISION PHASES 7, 98, 11A & 11B AS RECORDED IN PLAT BOOK 77, PAGE(S) 79-86, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve#1 Length I Radlue Delta Chord Beating Chord CI 5282' 2000.00' '1*2B!Or N0475'O5'W_ 52.82' C2 49.62' 1935.00' 1'WO9" S0475`05"E 49.62' C3 508.34! 2100.00' 1352'09" S0420'33*E 507.10' C4 2.30.02' 2100.00' 6-118'33' SO0-Jr46'E 229.91-1 C5 278:32• 211D0-00' 71 '36- S0778`49-E 278.11; FS z pl 1, 30 GRAPHIJ SCALE 0 15 30 LOT 13 qBLOCK 7 (REFERENCE BEARING) to 125.00 N86-18'59*E N86-18 5 AQ 9 E a U ——— 42.8' -0 __j 51.7 oD 8. r- r o Mn I T 6 0 'a 4.r 0 —4 0 22.6' _j > 0 C; ;O> 59.7' SPA 0 215 125-00' S84-50'50"W (NON—RADIAL) LOT I BLOCK 7 ON LOT CALCULATIONS LOT - 6,042 SO. FT. LIVING AREA = 1,828 SO. FT. PI GARAGE = 430 SQ. FT. ENTRY = 16 SQ. FT. LANAI = 88 SQ. FT. PATIO = 0 SO. FT. DRIVEWAY = 521 SO. FT. A/C PAD = 12 SO. FT. WALKWAY = 27 SO. Fr. IMPERVIOUS = 48% PREPARED FOR: = 21322 So. FT. SOD - 3.120 SO. FT. B-H-HOKIRW OFF LOT CALCULATIONS RIGHT OF WAY = 1355 SQ. FT. DRIVE APRON - 199 SO. FT. PUBLIC S/W = 265 SO. FT. BUILDING SETBACKS SOD = 891 SO. FT. FRONT- 22' TOTALS REAR: 15' AREA = 7,397 SQ. FT. SIDE. 5' (50' LOTS) DRIVEWAY - 720 SO. Fr. 7.5' (55' & 60' WIDTH LOTS) SIDEWALK = 292 SO. FT. SIDE STREET. 15' SOD - 4.011 SQ. FT. NOTES: 1. ELEVATIONS SHOWN ARE PER LOT GRADING PLANS PROVIDED BY THE CLIENT. LEGEND: 2. ELEVATIONS ARE BASED ON NAVD 1988 DATUM. BUILDING SETBACK LINE PI POINT OF INTERSECTION 3, FOR ALL LOTS WHERE SIDE—YARD CEN PC POINT OF CURVATURETERUNE PT POINT OF TANGENCY SETBACKS ARE LESS THAN 7.50 FEET, A RIGHT OF WAY LINE RP RADIUS POINT MINIMUN &00 FOOT WIDE DRAINAGE AND PRC POINT OF REVERSE CURVATURE ACCESS EASEMENT IS REQUIRED PER PASCO PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE COUNTY LAND DEVELOPMENT CODE. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE CS( PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF IC CALCULATED THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER W PLAT BOOK PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/w SIDEWALK SO.FT, SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVID NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVID NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&LI71U7Y EASEMENT THIS IS A PLOT PLAN ONLY POE PRIVATE DRAINAGE EASEMENT FLOOD NOTE: PUE PUBLIC UTILITY EASEMENT SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M.MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26,2014.AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE V.AREAS DETERMINED TO BE OUTSIDE THE 0 2X ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO OF WAY. RESTRICTIONS OF RECORD WHICH GUARANTIES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE MAY AFFECT THE TITLE OR USE OF THE LAND. LOCAL F.E.M.A.AGENT FOR VERIFICATION. 2, NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE NORTH UNE OF LOT 112, A!5hA 3. NOT VALID WITHOUT THE AUTHENTIC BLOCK 7 BEING N66181591E.PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M P- FR I c� r-,j ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: SURVEYOR AND MAPPER. SCALE: 11"-30 FEET S U FR VE --KI N C Digitally signed by Jim Bateman gCM DMC-11miloleman.—American APPROVED BY: ja APPING INC. Surveying&Mapping,au, 180820 LOT 1Z CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 emall=Jboleman@asmcorporatex 3191 MAGUIRE BOULEVARD, SUITE 200 run,-IJS FOR JOB NO. BLOCK 7 ORLANDO, FLORIDA 32803 Date 2019.01.28 08:29:35-05'00' THE DS9 — (407) 426-7979 FIRM DRAWN BY, PLOT PLAN 01/2312CHO JL WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOI EMAN PSM# 6485 DATE