HomeMy WebLinkAbout19-21420 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 21420
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:21420 Issued: 6/24/2019 Address: 6328 COBBLE BLISS ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 383,685.90 Total Fees: 15,775.19 Subdivision: SILVERADO
Amount Paid: 15,421.19 Date Paid: 6/24/2019 Parcel Number: 04-26-21-0110-00800-0020
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA, FL 33607
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,466 SQ FT
APPLICATION FEES
P MBING FEE 294.00 ELECTRICAL FEE 441.00 MECHANICAL FEE 205.80
SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32
TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 2,074.20 PARK FEES SF 769.56
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
e�
Inspections Required'
FOOTER 2ND ROUGH PLUMB Misc INSULATION EI ING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
RA ORS SIGNATURE PERMIT OFFIOFA
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - B HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Lennar Homes-6328 Cobble Bliss St:3,406 sqft
Column
SQ. FEET PRICE .- =
MAIN OR LIVING: 3,406 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 383,685.90 Py, b
FEE SHEET $ 1,960.00 b 6bb
ADDRESS $ 30.00 2 �6 t 1
DRIVEWAY1 $ 45.00
BUILDING: $ 2,074.20
ELECTRICAL: $ 441.00
PLUMBING: $ 294.00
MECHANICAL: $ 205.80
SUB-TOTAL $ 3,015.00
TOTAL $ 3,015.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ -
WATER METER:
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00 15 i'7 7 5.- 1 9
FIRE $ 273.00 15 s 47 a - 1 9. --
5% $ 26.35 300 +J 0 G`s-
TOTAL: $ 553.35
0oC
SUB-TOTAL $ 3,568.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,728.00
100.0% $ 7,728.00
1.0% $ 77.28
TOTAL: $ 7,805.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 15,775.19
PASCO COUNTY, FLORIDA
Permit No. - 7-NZO
Date Permitted 4�
Builder Name/Owner Name /v4' ama Control
County Parcel No, ubDIv: C/lbet-4
Address/Location 51o.1116, All-au -,y7-
Classification/Type of Use tar 3,-,/d
TRANSPORTATION IMPACT FEE Rate: Sq-Ft Unit.
Exempt n Yes [] No How Determined
Impact Fee Amount. $, 3166;?,a Zone No. TAZ*
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 1606,
(057) Mobile Home
(058) Other Residential
(123) Collection Fee
Exempt []Yes n No How Determined
PARKS AND RECREATION FEE
Land.Account Land Credit Land Total
Recreation Account Recreation Credit -Recreation Total
Zone TOTAL AMOUNT $ 769 Sp
Exempt n Yes F] No HowQet6rmined
LIBRARY FEE
Land Accounf Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt F1 Yes n No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
v
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
' BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
`Date Received Phone Contact for Permittingg 813 363 __ 2891
1 1 1 1 1 1 1 1 I l l i l
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 6328 Cobble Bliss Street LOT# 0020
SUBDIVISION Sllverado Ranch Subdivision Ph 6,8,9A PARCEL ID# 04-26-21-0110-00800-0020
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR E
ADD/ALT 0 SIGN Q Q DEMOLISH
—�� INSTALL REPAIR
PROPOSED USE SFR COMM = OTHER
TYPE OF CONSTRUCTION ry(I BLOCK 0 FRAME = STEEL =
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 3406 SQ FOOTAGE 2576 HEIGHT 1 Story
BUILDING 1'3, 'N4
a VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $ AMP SERVICE ® PROGRESSENERGY Q W.R.E.C.
• r
PLUMBING 1
$
0MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS W1 ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA DYES Flo
. L—I
BUILDER COMPANY Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4600 W.Cypress St.Ste.20 ampa,FL 33607 CGC1518166
License#
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 1034 Skipper Road, Tamp , FL 33613 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREK Y/N
Address P.O. Box 5308, Bayonet, F 34674-5308 License# CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N
Address P.O. Box 5308, Bayonet, F 741PO8 License# I CAC058062
OTHER COMPANY C Sterling Quality Roofing, Inc,
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address 4211 Shoal Line Blvd, Spring Hi I, FL 34607 License# 1 CCC057991
ttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttttt
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance,
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
t t t t t t t t t t . . .
Directions:
Fill out application completely. -
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned undenstandothatthispermitnloybooubjeotto"dL-d'neotrictiono^ �
which may ba more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake vvprk, they may be required to be licensed in accordance with state and |ono| regulations. If the
contractor is not |iuonnad as required by |aw, both the owner and contractor may be cited fora misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended vvork, they are advised to contact the Pasco County Building Inspection'Division—Licensing Section ed737-847-
8O0G. Furthennnpe, if the owner has hired a contractor orcontractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION \K8PACT/UT|LlT|ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing bui|dingo, or expansion of existing buUdingn, as specified in Pasco County {}vdinonoa number88-O7 and
90-87. as amended. The undersigned also underotonda, that such feea, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving o "certificate of occupancy" or final power release. If the project does not involve o certificate of occupancy or
final power oe|eoaa, the haeo must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 71%. Florida Statutes, eammnendad): |f valuation of work io$2.GOO.ODor more, |
certify that |, the opp|ioant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
PrntactionGuide" preparedbytheF|ohdaDepodmentofAgricu|turaandConmu[nerAffairm. |f the applicant issomeone
other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the"mwner^ prior tocommencement.
CONTFACTOR'S/OVVNER'SAFF|DAV|T: | certify that all the information in this application io accurate and that all work
will be�dona in compliance with all applicable |evvm regulating coVntruction, zoning and land development. Application is
hereby made to obtain o permit to do work and installation as indicated. | certify that no vvork or installation has
commenced prior to ioauonma of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City uodau, zoning regulations, and land development regulations in the jurisdiction. | also
certify that | understand that the regulations of other government agencies may apply to the intended vvork, and that it is
nny responsibility to identify what actions | must take tobeincompliance, Such agencies include but are not limited to:
' Department ofEnvironmental Protection-Cypreoo Bayheads. VVet|andAneao and Environmentally Sensitive
Lands,Water/Wastewater Treatment. '
' Southwest Florida Water Management Dimtriut-VVm||o, Cypress' Bayheadm, Wetland Anaos, Altering
Watercourses.
' Army Corps ufEngineero-GemwaUo. Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit'VVeUo, Wastewater Treatment,
Septic Tanks.
- UG Environmental Protection Agency-Asbestos abatement.
- Federal Aviation/\uihority+Runwoyo.
| understand that the following restrictions apply to the use offill:
- Use of fill io not allowed in Flood Zone"Vr unless expressly pannitted.
- If the fill material is to be used in Flood 3bna "A", it is understood that o drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State ofFlorida.
' If the fill material is to'be used in Flood Zone "A" in connection with a permitted building using stem vvaU
construction, | certifv{hat fill will beused only bo fill the area within the stem wall.
- If fill material is to be used in any area. | certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent propediea, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots |eoa than one (1)
acre which are elevated by fill, an engineered drainage plan iorequired.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. | understand that o separate permit may be required for electrical vvnrk,
p|umbing, uigna, vveUa, poo|o, air conditioning, gao, or other installations not specifically included in the application. /\
permit issued oheU be construed to be a license to proceed with the work and not as authority to vio|ate, cnnma[ alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring o correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit insuonne, or if work authorized by
the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension
may be pequemb»d, in writing, from the Building Official for o period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF;1 COMMENCEMENT,
OWNER OR AGEN� CONTRACTOR 1 0 1- 01
Subscribed and swoMqQ(KriiftrrKd)'I56fore me this 4
-Subscribed u —
--
Who is/are personally known to me or har.1have pFodueed Who is/are pemnally known to me or has/have Pfeda
Cnmm|suiunmo. FB98537 Commission No. 537
ElissuM.Holleran ` ElisuuM.Holleran
INSTR#2019102469 OR BK 9924 PG 357 Page 1 of 1
06/17/2019 02:30 PM Rcpt 2064233 Rao:10.00 IDS:0.00 IT:0.0D
PauCa S.O'X64 P/LV., Pasco County CCerk&Comptroller
Permit No. Parcel ID No 04-26-21-0110-0080041020
NOTICE OF COMMENCEMENT
State of Florida county of Pasco
THE UNDERSIGNED hereby gives notice that Improvement will De made to certain real property,and in accordance with Chapter 713,Florida Statutes,_
the following Information Is provided In this Notice of Commencement:
1.: Description of Property: legal SILVERADO RANCH SUBDIVISION PHASE 5A PB 78 PG 33 BLOCK 08 LOT 02
SheetAddress: 6328 Cobble Bliss Street Zephryhigs FL 33541
2 General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Intornatiorr. .Lennar Homes,LLC.'
Name
-4600 W QMress St Ste 200 Tampa- R 3j607
Address City State
Interest hr.Pmperty:
Name of Fee.Slmple Titleholder N/A
(If other than owne f)Addresaj
'
4. Contractor Lennar Homes,LLC ' city - - - state
4600 W CyP%.St,Ste 200 Tampa FL,33607
Address City State
Contractor's Telephone No.: 813.574.5700
surety:uwdh .N/A
Name
Address• City State .
Amount of Band:S Telephone No.:
6. Lender. N/A �® •°
Name ®�� •°" �-
'Address CRY State
Lender's Telephone No.: f
7. Persons-within the Slate of Florida designated by the owner upon whom notices or other documents may be served as provided by _ ° p' L6
Section 713.13(1)(a)(7),Florida Statutes:
ennarHomes I-LC
Now
4600 W Cypress St'Ste 200 Tampa FL.33607
Address
CRY. state
Telephone Number of Designated Person: 813.574.5700 q ,�® �e 4
8 In addlfion to himself,the owner designates NIA of_ �@
to receive a ccpy of the Uenoes Notice as provided in Section 713.13(1)(b),Florida Statutes. Q LLI
Telephone Number of Person or F-t ty Designated by Owner. co Z U I `L
Cam] v U_ 11_ L�J
9. Expiration date of Notice of Commencement Is one year from the date of recording unless a different date is specified: - �'�2-j U uJ U
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT (13 J
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART-1, SECTION 713.13. FLORIDA STATUTES, AND CAN /i U —i N
(—
RESULT IN YOUR'PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE Ida UUJ ) FZ- V Q
RECORDED AND POSTED ON THE JOB SITE BEFORE THE RRST.INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT.
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. O�Z � C Q
STATE OF FLORIDA �� 'L
COUNTY OF PINELLAS . Ul � U
Signature of Owner or Owner's Authar¢ed Oftcer/DlrectodPar rwr/Manager -- U I_r
Vice President °'� I- ,L Ll
Slgnatoys TiOe/Office. Q
The foregoing Instrument was acknowledged before me this 9 day of APriI 7 .by - r'a r.)
Steve Robert Smith as Vice President (type of arutb ofilotilrer�, tee,attcmey in fact)for ;Z; L I U 7 tL
Lennar Homes LLC (name of party on ehalf f6m instnanerd was executed):
U
BL W OILS Q
Personalty Known■�Produced Identification[I Notary Signature (j J C)y..
Type of Identification Produced Name(Print) Issa Holleran - elf
Verification pursuant to Section 92 SM,Florida Statutes. Under penaltles of perjury.I declare that I have read the.fdregoing and that the fads stated In 3 L (0 <C rco
h are true to the best of my Imowledgeand•belief. ��f c ti C�j LL .-7 <
:Mi
LIERAN Signature of Natural Persen Signing AboveOFFiESt(11' cLMwpdete/ba/bn fartm: Fx1olnwuat0G3{Fiplp
Y
D
Q r
{
r
1 �
Single Family Dwelling
Plan Review Comments
1. F.F.E; shall be a minimum of 8" above the road elevation and an engineered site plan.
2. Lots shall be graded to comply with R401.3 of the F.B.C.
3. Compaction test required if 24" or more of fill dirt is brought in at any one place.
4: Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use per it: A114 sides of driveway thru the sidewalk shall have
expansion material.
6. All setbacks shall be met.
7. All property markers shall be uncovered and marked at time of first inspection.
8: A11 A.D.A.requirements shall be met:
9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and
approval first.
10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation).
11. Appliances shall not be installed in a location where subject to mechanical damage unless
protected by approved barriers. M303;4 of the F.B.0
12. Water heaters shall comply with section P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1
14: Return air in all bedrooms. F.B.C. M1620:4
15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C.
16. All glazing requirements are to be iri accordance with R308.4 of the F.B.C.
17. All means of egress are to be in accordance with R311 of the F.B.C.
18. "Green gypsum board" shall riot be used as a backer in showers or tubs. R702.4.2 F.B.C.
10. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker.
20. Carbon monoxide alarms will be required in new construction that.uses fossil-burning heating
or appliances or an attached garage. They shall be-installed in accordance with the F.B.C:
21. All plumbing, mechanical, and electrical shall be separate from unit to unit: This includes all
underground plumbing and electric.
M All 2016 N.E.C. Codes will be enforced.
r
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0
24. In accordance with the Land Development Code, lots shall be sodded before final at least 10
feet around the structure.
25. R403.5.3Hot water pipe insulation
Insulation for hot water pipe With a minimum thermal resistance (R.-value) of R-3 shall be applied to the
following:
Piping 31, inch (19.1 mm)and larger in nominal diameter.
Piping serving more than one dwelling unit.
Piping located outside the conditioned space.-
Piping from the water heater to a distribution manifold.
Piping located under a floor slab:
Buried in piping.
Supply and return piping in recirculation systems other than demand recirculation systems.
25. Blower door test shall be provided before C.O.
26.A copy of the energy.cacls shall be.with permit at all times
27. Copy of final insulation repoit shall be provided with permit beforQ fnaL
28. No fence, pool or enclosure Is issued with.this pern:iZ
F.F.E.-Finished Floor Elevation
F.B.C- Florida Building Code 6t'Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016)
SKETCH ONLY SEC. 04 , TWP. 26 S, RNG. 21 E.
—PILOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS:
"LOT 2, BLOCK 8
SILVERADO RANCH SUBDIVISION PHASE 5A WEST BOUNDARY OF SUBJECT PLAT BEING N 3642*29" E
PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND
PRELIMINARY DRAWING: N NOTES TAKE PREFERENCE.
THIS PLAN IS FOR PERMITTING PURPOSES ALL DATA SHOWN HEREON BASED ON THE
ONLY, NOT FOR CONSTRUCTION. VERIFY '0 ENGINEERING PLANS OF HAMILTON ENGINEERING
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. & SURVEYING, INC,, PROVIDED BY LENNAR
II HOMES.
LEGEND: 10' UTILITY EASEMENT
nnn = PROPOSED DRAINAGE FLOW 10' DRAINAGE EASEMENT
(00,00) = PROPOSED GRADE
E-00.00 = EXISTING GRADE
En ON LOT AREA CALCULATIONS
LOT = L76�15LO_SQ. FT.
NOTES: + LIVING AREA 2576 —SO, FT.
LOT GRADING TYPE = A/B ENTRY = 57---SQ. FT.
PROPOSED PAD ELEVATION = 107.0' GARAGE =__A7_k___SQ. FT.
FRONT SET BACK = 20' COVERED LANAI =__NZ&___sQ. FT.
SIDE SET BACK = 7.5' PATIO =__N_/_k_SQ. FT.
REAR SETBACK = 15' GONG. DRIVE FT.
A/C & CONC PAD FT.
PRIVATE SIDEWALK 30—SQ. FT.
PC(P) IMPERVIOUS = 52
A9Z6_SQ. FT.
SOD ---17-87SQ. FT.
OFF LOT AREA CALCULATIONS
cg RIGHT OF WAY =--12-15.09—SQ. FT.
DRIVE APRON FT.
PUBLIC SIDEWALK = 337 Q. FT,
44, SOD = 528 S0. FT.
A
TOTALS
C.1 AREA = 8977-50 SQ. FT.
k104.46) DRIVEWAY =--2-77SQ. FT.
AO,
SIDEWALK = 367 --SQ. FT.
SOD — 4315--SQ. FT.
LOT 3
(b
BLOCK 8
x/.
Ro
r
(b
A5
PLAT
BOUNDARY
4L;C3
C,
q'Z: ro
O
000d)
q
CO
ka 7
Iry 31
GO
LOT 1
BLOCK 8 cjqe
tiw
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 107.70'
DESCRIPTION: GARAGE AREA: 107,16'
ELEVATIONS REFERENCED TO
LOT 2, BLOCK 8, MAP OR PLAT ENTITLED "SILVERADO RANCH NORTH AMERICAN VERTICAL
SUBDIVISION PHASE 5A", AS RECORDED IN PLAT BOOK 078, PAGES 033 DATUM OF 1988. MEAN SEA
THROUGH 037, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0452 F EFFECTIVE DATE: 9/26/14
Square Feet: 7762.50 t LENNAR HOMES
LEGEW
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U/P= UTILITY POLE, W/F= WOOD FENCE
Drawn By.
JOHN R.BEACH&ASSOCIATES,INC. sms
SURVEYORS AND MAPPERS Checked By,
t 911 WEST ST. PETERSBURG DRIVE JRB
ONE OLDSMAR, FLORIDA 34677
WAY (813) 554-1276 FAX (813) 855-8370 Scale;
V=30'
19
NOT VALID WITHOUT ORIGINAL SIGNATURE IDote: PLOT PLAN 4/25/ ACS
AND THE RAISED SEAL OF A FLORIDA S AI%I�E DATE
LICENSED SURVEYOR AND MAPPER _ -7 OHN R. 'K CH
Revisions: REVISED PER STREET NAME 5/30/19 J13S FLORIDA REG.V_AND SURVEYOR No. 2/4 LB#4493 I
TEFF M. HABXEY
PRO9AL SURVEYOR & MAPPER No.7123
1-2
u••!^.ys,
?� •�5��0 '' 5` 'd� ;, '',',�' i;� �'`�.,��y'a_ " ,�+j`.,. g(ag M1,'"�•q~\
-
- �tQ�. y4pti` .;Sfl �l r„ `}}, `.�,4 � ii; ,, `.%ttzt7;4 '`":�`t S'�t`"` /y9�'fi'57�,"^�•.+%9`+'• ..,,;r�,, ' '�- p,
at
r,. tt �'*` fl3 �- s•,7: fl
± p y B.Gq
ip6� ,'s , '"�.:. �'; �r ".. :+.,�."• "'t�,-. •95'
-/-541'S,.•�'30_$. '��'?l9" ! '� ;r'' !gab .,;b../ c7f �'S „�;iy�s��• g9 '�''`y,rs� g _ t �)'; ` `�,I! n.
'FFa
99,2Dr. ,F'_g
r S 5', 1 !Ct l'• l`%:s (.x ��'`d• rq I 0 8:80 S. tt
J,r""fl6-'- ;Sa. ,'� ..,�;7gt. ig ,' '"1,1�0:y ..1Fr_=1 0. i' l o- •?�,., 8$:5./�'a Q PAD�yB. FF�g$.60 t '�' OLI` �j
fl . `— iz`,1,X 0 �t1 " I rew P 1 LOT i V� .
5 - nk i. r PAD�g ^;q PAO=9i:9, t- CO TT
; ' R6 g6` @;, y,' /)'�T ,`'t Sfl2 a', ,tS'{y �'� � 9`S•' ''.�•4'� �' �Ak
� ;cl 4yfl1 l tQ� �a5�' �py�( �I,. �j ,�• `cS&' � FFrtOt•.60 l `,... t5�`--'.. —' ;r �#b,:i:, "�"'�;'�';.•..••�
} .r5 0 '�-.,�,0 _ .r.S �.r ,( i� t '`t y CaT'.5: 'h ""y;13`� 3°a-' r_g+.t' �:•�:i `/-..1-�O
o } tv?': �•-�t S �. � i`: :F` � '' Pgp_)04.9''. _'- ?62' ' — _ :'� 9`r Q
Irk � i, �i `,. •195.�9�; '�`' ., t3 n O�:
•�6� pa � Df• r' - : ..�.sa ;��'`'"s;�'��iz�':t': -7" ,�'• 1 -rg9:
Oc If '(3Qjt:t4,. '� 'l: :.,,:.' .r• =yy ••.b; � ".`..',.t"y,. �:' jQ PI/Mp
r ST AT ION
_ y ' i 3:- PAD
Ex
`rQ tiSGr q_i `'•t 0 ; i i �'� :.• ,,,�,+•" ' •-✓G. 9'a' �,9
•� -r;?0 � , �3°°' 2• ��`__-' ' '':FF� '' 'J 3�.�.it" g3'`--.r ^_ g?. '4 �'�"`� f? `" ,�q5,
106`20',
r a• PAD_ r, , ,g 57A
9/llZtt3
NT a 1 TYP g �J Q fg F.F� 1a. 1 ' STAnON
o � •y f' .('� z.� 1' , Itid•Sv, �s. '�_��< '� ACGE�
o. a� V COT 5. F98.80 fie7' �, bRltrE
a Ftp1 to o .5 1• '?o`, - �<�2 FF�t 10 �gghfl
p. 08:00 LOT
L'up
PAD:T 2'. � '.,._, Vi' PAp a• A
t,.
1YA 10?;3, ! "K T +,. ti._ 7 1Yp1r'
1D4.90;'
m ti ~i > r o 0� ```'`:• i r 3 OT:Q ,vg.- -t-. Qf' t � `fi.: S9
� � >,D ,ttp1,. _ -�/. ;a:r• 'f,. , r g' PADT 0 `... ,' g9�:.
LOr..1 a• i ,' t., /r t g..j .g0', 1J• tj �gJ�`` S• ��' ?�- AD`1 Ug
TWZ
-•" �;v' F�l._ �-1 ��` •t- A� _ rr t �-� }..f•gyp.v � ar�'° ; ;'r AO� ����titi�y7.g i~�`` _ °�' 9
;a1._ - •.,,, fi;, t�q.: D`145,Q
!�`''�:�— :��_�r �' ;�fl$.�, �.�' '1 ` r ,rj'v-s � r •1' ,'' ' q'�'•g g1 rg �'�'� /
:`��_. E{tPlQC�'�p �~ w" .4 r ;�`�y f y �� } '3i l :y``9`�' ;�g.Fy,3'Sg __---- -=�h�'•
,; �•lr�."� ',`'' -- --a..t. BUff=E. _pS..` .�a ,�-�� �> ,.�, s FF�,r•D?,'�+ ,}j P,y � -f,. 1 4'L�g�• ,•. .rqa, y,Ab:.. ,g��
ARU
Tg5 13" ` �ftrF — _ ,s �r• i.!` NP Af9 1� r y# f kg 45 "1 gw}d gt�iy6. ' 9 p°J' y\'J
.N .t►"a,.. ,}�;�5. "_,1, '�`'*.._, - 'YS' \``''``ti !r.: '+U Y ; > \� � i `,; yy '.(.S �G�y ', ��'j" ', .l
" .:rs.�S.--, g- — .fig ,}�G• �t, ; rl } a6•a .kssac'i�9, 4g
ri
yto` a.' Q... `''i.. id9.p0,, ;. r i '1 •F � 1t,
r,, .-_ � F1�`•. ""1 '�� ,�,: �. `,,` it
; ,. V08:3'.1Cy j kgrlc
Ogg �ti: S'S:• 1YP g 8:. '� < '�r _ ` -� .. ; t gy;� i fl ;' '-;i�, ` �
tb g � `:5. /'
.•rS .� � '\',' _ •Sfl`. 1,1C.: .c• �a' ,1-{•1. � 1 �'s.� �. } , St •{.g -`►'`-
,L `,`S.S
IN
XYA
1,�_ (� •i, , Xa
>•/7,FE 'r t1' i i./ ' ., �:7 �'.�. �i. �.'' � �'��-9C1",`S� r`' �jQ�• �.
i'• "��4�%.fF ' ' ��' �I. �"f<. i,�}/ t�,gEr, •;c• �, g:`�;9'��� ,'�g�,, �syC,$S• � ����,YI
., ``,� iYg,x , �• ek•,, `, g�.�
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2606A sf ADS Carrier VW Builder Name: Lennar Homes 0802
Street: 6328 Cobble Bliss Street Permit office: Citysf Zephyrhills
City,State,Zip: ,FL, Permit Number: 2;1 q 2,0
Owner: Lennar Homes Jurisdiction: -,61120 az
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2
b.Frame-Wood,Adjacent R=11.0 380.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (2576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2576.00 ft2
6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2
a. U-Factor: Dbl,U=0.33 159.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50
c. U-Factor: Dbl,U=0.33 16.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.372 ft.
Area Weighted Average SHGC: 0.245 14.Hot water systems
8. Floor Types (2576.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.083 Total Proposed Modified Loads: 70.71 PASS
Total Baseline Loads: 73.00
I hereby certify that the plans and specifications covered by Review of the plans and ti' :ST `
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance �i :'; •
with the Florida Energy Code. F., n/u ';.�. `u O
PREPARED BY: Dave Atdp ch Before construction is completed
DATE: this building will be inspected for 0. '- C
compliance with-Section 553.908 *, •:. ° �,
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certificati by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house.
1/15/2019 1:05 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2606A sf ADS Carrier VW Builder Name: Lennar Homes 0802
Street: 6328 Cobble Bliss Street Permit Office: City f Zephyrhills
City,State,Zip: ,FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ft2
b.Frame-Wood,Adjacent R=11.0 380.00 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (2576.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ft2
6. Conditioned floor area above grade(ft2) 2576 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c. R= ft2
11.Duct
s R ft2
7. Windows(215.0 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515.2
a. U-Factor: Dbl,U=0.33 159.00 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.58 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 35.0 SEER:15.50
c. U-Factor: Dbl,U=0.33 16.00 ft2
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.372 ft.
Area Weighted Average SHGC: 0.245 14.Hot water systems
8. Floor Types (2576.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 2576.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.083 Total Proposed Modified Loads: 70.71 PASS
Total Baseline Loads: 73.00
I hereby certify that the plans and specifications covered by Review of the plans and "l
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
Wl with the Florida Energy Code. ti.' Cirri:, "°:.N '
PREPARED BY: ti HM Before construction is completed
DATE: this buildingwill be inspected for
P Q.
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes. +
with the Florida Energy Code.
OWNER/AGENT: BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house.
1/15/2019 1:05 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation Residential Performance Method
Project Name: 2606A sf ADS Carrier.VW Builder Name: Lennar Homes 0802
Street: 6328 Cobble Bliss Street Permit office: City f Zephyrhills
City,State',Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction: 611200
Design Location: FL,Tampa County: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1900.0 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1520.00 ftZ
b.Frame-Wood,Adjacent R=11.0 380.00 ft
3. Number of units,if multiple family 1 c.N/A R= ftZ
4. Number of Bedrooms 4 d.N/A R= ftZ .
10.Ceiling Types (2576.0 sqft.) Insulation Area.
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2576.00 ftZ
6. Conditioned floor area above grade(ftZ) 2576 b.N/A R= ftZ
Conditioned floor area below grade(ftZ) 0 11.Du cctt c.N R= ftZ
s R ft?
7. Windows(215.0 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 515:2
a. U-Factor: Dbl,U=0.33 159.00 ftZ
SHGC: SHGC=0.23
b. U-Factor: Dbl,U=0.58 40.00 ftZ 12.Cooling systems kBtu/hr Efficiency .
SHGC: SHGC=0.32 a.Central Unit 35.0 -SEER:15.50
c. U-Factor: Dbl,U=0.33 16.00 ftZ
SHGC: SHGC=0.21 13.Heating systems kBtu/hr Efficiency .
d. U-Factor: N/A ftZ a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area:Weighted Average Overhang Depth: 1.372 ft.
Area Weighted Average SHGC: 0.245 14.Hot water systems
a.Electric Cap:40 gallons .
8. Floor Types.(2576.0 sqft.) Insulation Area
EF:0.950
a.Slab-On-Grade Edge,Insulation R=0.0 2576.00 ftZ b. Conservation features
b.N/A R= ftZ None
c.N/A R= ftZ 15.Credits Pstat
Total Proposed Modified Loads: 70.71 w C c
Glass/Floor Area: 0:083 ASS
Total Baseline Loads: 73.00
.I hereby certify that the plans and specifications covered by - Review of the plans and
this calculation are in.compliance.with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. ti r�r,+ � ;° . .+ „ O
')ave lal _
PREPARED BY: ��� Before construction is completed r
DATE: this building will be inspected for O -1
compliance with Section 553.908 * a
I herebycertify that this building,as designed, is in compliance Florida Statutes.
fY 9� 9
with the Florida Energy Code. O!7 y{
OWNER/AGENT: BUILDIN FICIAL-
DATE: DATE:.
=:'Compliance requires certification.by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
Compliance requires an Air.Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00:ACH50(R402.4.1.2).
Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn.for whole house.
1/15/20191:05 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Pagel of 4
FORM R406-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: 2606A sf ADS Carrier VW Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2576 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Vinyl windows
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture 'Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 2576 20608
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InflID Finished Cooled Heated
1 Main 2576 20608 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 174 ft 0 2576 ft2 ___ 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2790 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
/ ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 2576 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 2576 ft2 0A 1 Wood
1/15/2019 1:05 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below 4 C)rnt To Wall Type
_ 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 18 8 8 149.3 ft2 0 0.600000 0
_ 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 67 4 8 538.7 ft2 0 0.600000 0
_ 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 53 8 424.0 ft2 0 0.600000 0
_4 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 7 8 56.0 ft2 0 0.600000 0
_ 5 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 44 8 352.0 ft2 0 0.600000 0
6 N=>NE Garage Frame-Wood Main 11 31 8 248.0 ft2 0.23 0.01 0
7 E=>SE Garage Frame-Wood Main 11 2 8 16.0 ft2 0.23 0.01 0
- 8 W=>NW Garage Frame-Wood Main 11 14 6 8 116.0 ft2 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Vinyl Low-E Double Yes 0.33 0.21 N 16.0 ft2 1 ft 0 in 4 ft 6 in Drapes/blinds Exterior 5
2 E=>SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
3 E=>SE 2 Vinyl Low-E Double Yes 0.33 0.23 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
4 S=>SW 3 Vinyl Low-E Double Yes 0.33 0.23 N 92.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
5 S=>SW 4 Metal Low-E Double Yes 0.58 0.32 N 40.0 ft2 3 ft 0 in 0 ft 3 in Drapes/blinds Exterior 5
6 W=>NW 5 Vinyl Low-E Double Yes 0.33 0.23 N 12.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
7 W=>NW 5 Vinyl Low-E Double Yes 0.33 0.23 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 674 ft2 674 ft2 57 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 2404.3 131.99 248.23 .2649 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.5 34.6 kBtu/hr 1 sys#1
1/15/2019 1:05 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R406 2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15.5 35 kBtu/hr 1050 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 515.2 ft Main 128.8 ft Proposed Qn Main —cfm 103.0 cfm 0.04 0.50 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling [[ ]]Jan [[ ]]Feb [[ ]]Mar [ ]Apr [ ]May [X]Jun Jul [X]Aug
Se [ ]Oct [[ ]]Nov Dec
Heatin [X]Jan [X]Feb [X]Mar [ ]Apr [ ]May [ ]Jun Jul ' [ ]Aug Sep [ ]Oct [X]Nov Dec
Ventin [[ ]]Jan [[ ]]Feb [[X]]Mar [X]A r [ ]Ma [ ]Jun Jul [ ]Au Se [X]Oct [[X]]Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
MASS
Mass Type Area Thickness Furniture Fraction Space
Default(8 Ibs/sq.ft. 0 ftz Oft 0.3 1 st Floor
Default 8 Ibs/sq.ft. 0 ftZ Oft 0.3 2nd Floor
Name: Signature:
Rating Compant: Date:
1/1 5/201 9 1:05 PM EnergyGauge®USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New(From Plans) 12. Ducts, location&insulation level
a)Supply ducts R 6.0
2. Single-family or multiple-family 2. Single-family b) Return ducts R 6.0
c)AHU location Attic/Main
3. No.of units(if multiple-family) 3. 1
4. Number of bedrooms 4. 4 13.Cooling system: Capacity 35.0
a)Split system SEER 15.5
5. Is this a worst case?(yes/no) 5. Yes b)Single package SEER
c)Ground/water source SEER/COP
6. Conditioned floor area(sq.ft.) 6. 2576 d) Room unit/PTAC EER
e)Other
7.Windows,type and area
a) U-factor:(weighted average) 7a. 0.377
b)Solar Heat Gain Coefficient(SHGC) 7b. 0.245 14. Heating system: Capacity 34.6
c)Area 7c. 215.0 a)Split system heat pump HSPF
b)Single package heat pump HSPF
8. Skylights c) Electric resistance COP
a) U-factor:(weighted average) 8a. NA d)Gas furnace, natural gas AFUE
b)Solar Heat Gain Coefficient(SHGC) 8b. NA e)Gas furnace, LPG AFUE
f)Other 8.50
9. Floor type, insulation level:
a)Slab-on-grade(R-value) 9a. 0.0
b)Wood,raised (R-value) 9b. 15.Water heating system
c)Concrete,raised(R-value) 9c. a) Electric resistance EF 0.95
b) Gas fired, natural gas EF
10.Wall type and insulation: c)Gas fired, LPG EF
A. Exterior: d)Solar system with tank EF
1.Wood frame(Insulation R-value) 10A1. e) Dedicated heat pump with tank EF
2.Masonry(Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%
B.Adjacent: g)Other
1.Wood frame(Insulation R-value) 10131. 11.0
2. Masonry(Insulation R-value) 10132.
16. HVAC credits claimed (Performance Method)
11.Ceiling type and insulation level a)Ceiling fans
a) Under attic 11a. 30.0 b) Cross ventilation No
b)Single assembly 11 b. c)Whole house fan No
c) Knee walls/skylight walls 11 c. d) Multizone cooling credit
d) Radiant barrier installed 11 d. No e)Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation,through the above energy
saving features which will be installed(or exceeded)in this home before final inspection. Otherwise, a new EPL
display card will be completed based on inst ed code compliant features.
Builder Signature: Date: 05/02/19
Address of New Home: 6328 Cob e Bliss Street City/FL Zip: , FL Zephyrhills,FL 33541
1/15/2019 1:06:21 PM EnergyGauge®USA 6.0.02-FlaRes2017 FBC 6th Edition(2017)Compliant Software Page 1 of 1
Buildin Anal sis Job: 2606AsfADSVWSR
g y Date: 512/2019
Entire House By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950.New York ave,Hudson
Project • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD-(°F) 39 16
Latitude: 280N Relative humidity (%) 50 50
Outdoor: Heating- Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ftz Btuh % of load
Walls 5.0 10504 31.3 Duds
Glazing 21.3 4555 13.6
Doors 19.6. 746 2.2 Wall nfiltration
Ceilings 1.3 3231 9.6
Floors 2.9 7385 22.0
Infiltration 2.2 3433 10.2
Ducts 3687 11.0 Piping 0 0 Floors
Humidification, 0 0 Glazing
Ventilation 0 0 Doors Ceilings
Adjustments 0
Total 33542 100.0
'Component Btuh/ftz Btuh % of load
Walls 2.4 5107 . . 18.0 W _ Internal Gains
Glazing 46.7 9987 35.1 Walls
Doors 15.4 584 2.1
Ceilings 1.7 4468 15.7 Ducts
Floors 0 0 0
Infiltration 0.4 714 2.5
Ducts 3602 12.7 Ventilation 0 0 Infiltration
Internal gains 3980 14.0
Blower 0 0 Glazing Ceilings
Adjustments 0
Total 28442 100.01 Doors
Latent Cooling Load=3445 Btuh
Overall U-value= 0.090 Btuh/ftz-°F
Data entries checked.
t # wrightsoft® 2019-May-02 06:32:59
�+ °^°^•� ^•^•w-•°°^P� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
�� ...ipment\2606 sf ADS template VW 3ton Carrier.rup Cale=MJ8 Front Door faces:NW
Project Summary Job: 2606A sfADS VW SR
1 Date: 5/2/2019
Entire House By: Dave Aldrich .
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
• Information
For: Lennar Homes
Notes: Vinyl windows
Shingle roof
Desian Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range . L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 29855 Btuh Structure 24840 Btuh
Ducts 3687 Btuh Ducts 3602 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
Humidification 0 Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 33542 Btuh. Use manufacturer's data
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 28442 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2681 Btuh
Ducts 764 Btuh
Heating
Central vent (0 cfm) 0 Btuh
Cooling Area(ft2) (none)
2576 2576 Equipment latent load 3445 ,Btuh
Volume.(ft') 21723 21723
Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 31887 Btuh
Equiv.AVF (cfm) 80 40 Req. total capacity at 0.85 SHR 2.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade PERFORMANCE 15 HP Trade PERFORMANCE 15 HP
Model 25HBC537AO030 Cond 25HBC537AO030
AHRI ref 10487322 Coil FX4DNF037L
AHRI ref 10487322
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 29750 Btuh
Heating output 34600 Btuh @ 47°F Latent cooling 5250 Btuh
Temperature rise 26 OF Total cooling 35000 Btuh
Actual air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.036 cfm/Btuh Air flow factor 0.042 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point= 32 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved byACCA to meet all requirements of Manual J 8th.Ed.
t -F�F- wrigF�tsoft® 2019-May-02 06:32:56
Right-Suite®Universal 2018 18.0.16 RSU05714ACCK Page 1.
...ipment�2606 sf ADS template VW 3ton Carrier.rup Cale=MJ8 Front Door faces:NW
Manual S Compliance Report Job: 26 Date: 51212019 DSvwSR
2019
Entire House By: Dave Aldrich
Bayonet Plumbing Heating and Cooling
8950 New York ave,Hudson
Project • •
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 28442 Btuh Entering coil DB: 75.5°F
Outdoor design WB: 77.3°F Latent gain: 3445 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 31887 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L
Actual airflow: 1200 cfm
Sensible capacity: 29750. Btuh 105% of load
Latent capacity: 5250 Btuh 152% of load
Total capacity: 35000 Btuh 110% of load SHR: 85%-
Heating Equipment
Design Conditions
Outdoor design DB:- 30.8°F Heat loss: 33542 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance.Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC537A0030+FX4DNF037L
Actual airflow: 1200 cfm
Output capacity: 26719 Btuh 80% of load Capacity balance: 32 °F
Supplemental heat required: 6823 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
-0fil- wrightsoft- 2019-May-02 06:32:59
�� .R•�P Lbw»u-��ma; Right-Suite®Universal 2018 18.0.16 RSU05714
" Page 1
...ipment\2606 sf ADS template VW 3ton Carrier.rup Calc=MJS Front Door faces:NW
SKETCH ONLY SEC. 04 TWP. 26 S, RNG. 21 E.
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 2, BLOCK 8 BEARING BASIS:
SILVERADO RANCH SUBDIVISION-PHASE 5A WEST BOUNDARY OF SUBJECT PLAT BEING N 36'42'29'E
PASCO COUNTY, FLORIDA. T DO NOT SCALE THIS PRINT. DIMENSIONS AND
PRELIMINARY DRAWING:
1 NOTES TAKE PREFERENCE.
THIS PLAN IS FOR PERMITTING PURPOSES ALL DATA SHOWN HEREON BASED ON THE
ONLY,NOT FOR CONSTRUCTION.VERIFY a ENGINEERING PLANS OF HAMILTON ENGINEERING
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. n &SURVEYING, INC., PROVIDED BY LENNAR
HOMES.
LEGEND:.
..w—m PROPOSED DRAINAGE FLOW = 10'-UTILITY EASEMENT -
(00.00) PROPOSED GRADE . "= 10'DRAINAGE EASEMENT
E—DD.DO =EXISTING GRADE y ON LOT AREA CALCULATIONS
.. NOTES: LOT ="7762.50 SO.FT.
LOT GRADING TYPE= A/B LIVING AREA = 2578 .SO.FT.
PROPOSED PAD ELEVATION 107.0' ENTRY 57 -So.FT.GARAGE 674 --SO.FT. _
FRONT SET BACK=20' COVERED LANAI a N/A S0.FT.
SIDE SET BACK= 7.5' PATIO = N/A S0.FT.
REAR SETBACK-,15' CONC.DRIVE 627 S0.FT._
A/C&CONC PAD 12 S0:FT." _
PRIVATE SIDEWALK 30 S0;FT.
�PC(P) IMPERVIOUS = 52 z
3976SO•FT.
SOD = 3787 S0•FT.
OFF LOT AREA CALCULATIONS
0� RIGHT OF WAY = 1215.00 S0.FT.
/ ,o• DRIVE,APRON =-350 SO.FT.
PUBLIC SIDEWALK - 337 S0.FT.
!L SOD = 528 S0•FT,
��, y� TOTALS
L AREA = 8977.50 S0•FT.
-\ C, 3 (,04A ) DRIVEWAY = 977 S0.FT.
SIDEWALK = 367 SO.FT.
SOD = 4315 S0.FT.
1
vw ` �A' %�� LOT 3
BLOCK B
PLAT
�. .. .�. B •a OO. BOUNDARY
_ P:P
i
N� •.. q�o
K S3. yp
W J,,
� O
N S A
00, ti {
LOT 1
BLOCK 8
06
y
N
O
J
Y
a
PROPOSED:
^ LOWEST FLOOR ELEVATIONS:
x
4 LIVING AREA: 107.70'
v DESCRIPTION' GARAGE AREA: 107.16'
ct ELEVATIONS REFERENCED TO
LOT 2, BLOCK 8, MAP OR PLAT ENTITLED "SILVERADO RANCH NORTH AMERICAN VERTICAL
o SUBDIVISION PHASE 5A", AS RECORDED IN PLAT BOOK 078, PAGES 033 DATUM OF 1988. MEAN SEA
THROUGH 037, OF THE PUBLIC RECORDS OF PASCO COUNTY,. FLORIDA. LEVEL= 00.00 FT:
N APPARENT FLOOD HAZARD ZONE: ' COMMUNITY PANEL NO. 12101C 0452 F EFFECTIVE DATE: 9/26/14
,+¢i Square Feet: 7762.50 t LENNAR HOMES "
m
m(C)= CALCULATED DATA, (D)- DEED DATA, (M)= MEASURED DATA, (P)- PLAT DATA, q= CENTERLINE,A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S.
L CONCRETE SLAB,CH= CHORD,CHB= CHORD BEARING, CLF- CHAIN LINK FENCE, CONC-'CONCRETE, COV.- COVERED, E/P- EDGE OF PAVEMENT,ESM'T- EASEMENT, _
=F/C= FENCE :CORNER, FCM= 'FOUND CONCRETE MONUMENT, FIP=FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL"&DISK, FPP= FOUND PINCHED -
U PIPE,LFE= LOWEST FLOOR ELEVATION,MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT,PRM= PERMANENT
Z REFERENCE MONUMENT, R/W= RIGHT OF WAY, R=RADIUS,SIR-SET 1/2"IRON ROD &CAP No. 4493, SN&D- SET NAIL&DISK, TBM= TEMPORARY'BENCHMARK,
9 U P- UTILITY POLE. w - WOOD FENCE
JOHN R.BEACH Sc ASSOCIATES,INC. Drown By.
SMS
SURVEYORS AND MAPPERS
911 WEST ST. PETERSBURG DRIVE Checked By.
n ONE
. OLDSMAR,FLORIDA 34 'RB
n WAY (813)854-1276 FAX(813) 855-8370
Scale:
1• ILFJ�p NOT VALID WITHOUT ORIGINAL SIGNATURE Date: PLOT PLAN 4/25/19 ACS'
7 AND THE RAISED,SEAL"OF A FLORIDA SIG D
v LICENSED SURVEYOR AND MAPPER HN R. BEA
Revisions: ORIDA REG. NO SURVEYOR No. 2984 LB 4493
un
ii P FESSIONAL SURVEYOR&MAPPER No.7123