Loading...
HomeMy WebLinkAbout19-21421 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 21421 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:21421 Issued: 6/24/2019 Address: 6365 COBBLE BLISS ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est.Value: Book: Page: Cost: 340,315.65 Total Fees: 15,452.69 Subdivision: SILVERADO Amount Paid: 15,452.69 Date Paid: 6/24/2019 Parcel Number: 04-26-21-0110-00900-0050 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,021 SQ FT APPLICATION FEES PLUMBING FEE 261.75 ELECTRICAL FEE 392.63 MECHANICAL FEE 183.23 SCHOOL IMPACT FEE-sfr/1% 77.28 SCHOOL IMPACT FEE-sfr/100% 7,728.00 TRAFFIC IMPACT FEE 1% 36.32 TRAFFIC IMPACT FEE 99% 3,595.68 BUILDING FEE 1,854.89 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 �D Inspections Required FO TER 2ND ROUGH PLUMB MISC INSULATIONCEILING_ FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION-WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CO RS NGKKTffRff PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. 2 1 Date Permitted 16-05/2 Builder Name/Owner Name /e-f1&-zr A*r,,S7�,, Control County Parcel No, SubDIv: 5 LXY� Address/Location L5 6 T - Q 6Z e- <S7- L Classification/Type of Use k TRANSPORTATION IMPACT FEE Rate: Sq-Ft Unit: Exempt F1 Yes [:] No How Determined Impact Fee Amount, Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ Z 28 (057) Mobile Home (058) Other Residential (123) Collection Fee Exempt E] Yes n No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ Exempt F1 Yes E] No Howgetermined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt [] Yes F1 No How Determined Total Amoun� RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE I BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for Game. DATE RECEIVED BY RECEIPT NO. DATE BY INSTR#2019102474 OR BK 9924 PG 362 Page 1 of 1 06/17/2019 02:30 PM Rcpt:2064233 Rea:10.00 DS:0.00 IT:0.00 Paula S.O'NeiC,Ph.D., Pasco County Clerk&ComptroQer Permit No. Parcel ID No 04-26.21-0110-00900.0050 NOTICE OF COMMENCEMENT state of Florida county at Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,area in accordance with Chapter 713,Florida Statutes," the following information Is provided In this Notice of Commencement 1. Description of Property:Legal SILVERADO RANCH SUBDIVISION PHASE 5A PS 73 PG 33 BLOCK 09 RAT 05 street Address: 6365 Cobble Bliss Street zephryhfls FL 33541 '2. General Description of Improvement Single Family Residence/Pool/Sraeen Enclosure/Fence 3. Owner Information: Lennar Homes,LLC. Name 4600 W Cypress St.Ste 200 Tampa FL'33607 Address City State Interest In Property: Name of Fee Simple Titleholder NIA pf other than owner) Address City 4. Contmaor. Lennar Homes LLC 4600*CyNtarEs St,'Ste 200 Tampa FLi336W Address. City Stale Contractors Telephone No.: 813-574.5701) 5. surety:MW NIA Name Address City State Amount of Band:$ Telephone No.: 6. Lender: N/A Name Address city state Lender's Telephone No.: 7. Persons wltfrin the Stafe.of Florida designated by the avatar upon whom notices or other documents may be nerved as provided by Section 713.130)(a)(7),.Florida Statutes: Name Lennar homes.LLC ' k 4600 W Cypress St,Ste 200 Tampa FIB 33607 Address city State'' a Telephone Number of Designated Person: 813.574.5700 ' a. In addition to himself,the owner designates NIA of— to receive a Cow of the Uenots Notice as provided In Secdbn 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 4 LU ry W 9. Expiration date of Notice of Commencement Is one year from the date of recording unless a different date Is specified: co ,i t LL {� U) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT LL '- > ARE CONSIDERED IMPROPER PAYMENTS UNDER-CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES,AND CAN. 4- t7 !- RESULT IN YOUR PAYING TWICE FOR-IMPROVEMENTS TO YOUR.PROPERTY. A NOTICE OF COMMENCEMENT MUST BE t f3 — I-) fn J RECORDED AND POSTED ON THE JOB-'SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT- O <WITH YOUR GENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. C7 L r- LL } w STATE OF FLORIDA U, Q COUNTY OF PINELLAS �.G�� A Signature of Owner or Owners Authorized OBicer/Diredor/Parbrer/Manager Q U' 1 LY- U Vice President ' `p O LU_ -Signatory'sThielOffice `~ r L The foregoing Instrument was acimawiedged before me this 9 day of APril /L t_by Steve Robert Smith as Vice President (type of authorityoet/9�ontflftr,trustee,attorney In fad)for �i t �, Lennar Homes (nam e me of party on Instrument fi1G� `���Instrumentwas executed}. t LL. t u : 7 O Personally Known M.OR Produced Idenilflcation❑ r Natwy Stgnaftae' �! —�.,_ i= Ly- a- d � Type of Identification Produced Name(Prim) Eiissa Holleran w 0 o� �>_ Verification pursuant to Section 92.5Y5,Florida Stadutm Under penalties of perIury,I declare that!have rears the foregoing and that the fads stated in LA- O 0 iD {/} it are true to the best of my knowledge and belie{. 5i38AAtHt1L1FAAN Signa re��Signing Above cn E� ' Q 7 r CammiatobiPFltd6W ? t F1 ) Ct CO '�EgintJuead,IIGZG wpda{a/bcabcsfortrr :tWd+i11Pc1isMFcisWassri79a13ait! ` D Q 4 1 � Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and d an engineered site plan. 2. Lots shall be graded to comply with R461. 3 of the F.B.C. 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. 4: Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. All 4 sides_ of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8: All A.D.A.requirements shall be met: 9. No electric,plumbing,mechanical, or framing shall be covered without an inspection and approval first. 10: All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B:C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in' accordance with R308.4 of the F.B.C, 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum.board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in' new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C: 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2016 N.E.C. Codes will be enforced. 23. 'Pamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 feet around the structure. 25: R403.5.3Hot water pipe insulation Insulation for hot water pipe with a minimum thermal resistance (R.value) of R-3 shall be applied to the following: Piping l' inch (19.1 mm) and larger in nominal diameter. Piping serving more than one dwelling unit. Piping located outside the conditioned space: Piping from the water heater to,a distribution manifold. Piping located under a floor slab. Buried in piping. Supply and return piping in recirculation systems other than demand recirculation systems. 25. Blower door test shall be provided before C.O: 26. A copy of the enemy-cacls shall be with permit at all times. 2Z COpV of final-insulation report shall be provided with permit before rinaL 28.No fence,pool or screen enclosure is issued.with:this permit F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6d Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) .,1-780-0020 City of Zephyrhills Permit Application Fax-8*13-780-0021 Building Department ,.,,jatL-Re6elved Phone Contact for Permitting 813 363 2891 1 1 1 1 1 1 1 1 1 1 L-1-1 I I I I 1I A LJL_1� Lermar Homes,LLC r8B 574 5700 Own6es Name Owner Phone Number Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Nam. I N/A owner Phone Number Fee Simple Titleholder Address N/A LOT#365 Cobble Bliss Street JOB ADDRESS F I 0050 SUBDIVISION SlIverado Ranch Subdivision Ph 6,8,9A PARCEL ID# 04-26-21-0110-00900-0050 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED In/ NEW CONSTRR ADD/ALT SIGN Q Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure Fence BUILDING SIZE I U/R SF 3021 SQ FOOTAGE �278 HEIGHT 1 Story ✓ BUILDING VALUATION OF TOTAL CONSTRUCTION OELECTRICAL 1$ AMP SERVICE FX_� PROGRESSENERGY W.R.E.C. OPLUMBING 1$ 0 MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS W1 ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA . DYES Do . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDER COMPANY Lermar Homes,LLC - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -- - - - - - -- - - -- - I I SIGNATURE /,-.-r—REG,ST,RED Y/ N FEE CURREN LY/N Address �OW.Cypress St.Ste.200,T—M?pa,FL 33607 License# I CGC1518166 'IAN COMPANY ELECTRIC Edmonson Electric, Inc. SIGNATURE REGISTERED Y1 N I FEE CURREN Y/N Address 11034 Skipper Road,Tampa, FL 336p ,- License# FEC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O.-Box 5308, Bayonet, FL 34674-5 Oa, License# FCFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N A' 0, Address P.O. Box 5308, Bayonet, FL 34674-53 License# AC058062 c F OTHER COMPANY C Sterling Quality Roofing, Inc SIGNATURE, REGISTERED Y/ N FEE CURREN Y/N Address 14211 Shoal Line Blvd, Spring Hill, i_34607 License# 1 CCC057991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w(Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilitibg-&1-dUftipster,Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . DDirections;. Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone With notarized letter from.owner:authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if.shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned underubandathotthispermitrnoybeuubjectho^deed^ reathotono^ which may ba more restrictive than County regulations. The undersigned assumes responsibility for compliance with any . � applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor in not |imanood as required by |mw, both the owner and contractor may be cited for misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing naqu)nnmanto may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired o contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. |f you, am the owner sign aothe contractor, that may bean indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION |K8PACT/UT|L|T|ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing bui|dingo, or expansion of existing bui|dingo, as specified in Pasco County Ordinance numbar8Q'O7 and 90'07. as amended. The undersigned also undomtendm, that such fees, as may be due, will be identified ot the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power me|oaee. If the project does,not involve a certificate of occupancy or final power re|eane, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,asmnnended): |f valuation mf work io$2.50U.00or more, | certify that |, the applicant, have been provided with o copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver ittu the~mwner" prior tocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application ia accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain o permit to do work and installation as indicated. | certify that no work or installation has commenced prior to |aouenoe of o permit and that all work vviU-ba performed to meet standards of all /ewva regulating conatruoiion. County and City codeo, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Beyhaads, VVoUend Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. ' Southwest Florida Water Management Oistrict-VVeUu, Cypress Bayhaade, Wetland Anaaa` Altering Watercourses. - Army Corps ofEngineero-GemwaUs. Docks, Navigable Waterways. ' Department of Health & Rehabilitative Semioan/Envinonmental Health Unit4AeUo, Wastewater Treatment, Septic Tanks. ' U8 Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runvvayu. | understand that the following restrictions apply to the use offill: - Use nf fill in not allowed in Flood Zone"V" unless expressly permitted. ' If the fill material is to be used in Flood Zone "A". it is understood that o drainage plan addressing e "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State cfFlorida. - If the fill material is to be used in Flood Zone "A" in connection with d building using stem vxaU construction, I certify that fill will be used only to fill the area within the stem wall* - If fill msdoha| is to be used in any area, | certify that use of such UU will not admanoe|v affect ocUacard properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots (eaa than one (1) acre which are elevated by fill, an engineered drainage plan is required. |f| am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that o separate permit may be required for e|euthco| vvork, p|umblng, o|gno, xveUm, poo|o, air oonditioning, gao, or other installations not specifically included in the application. /\ permit issued shall be construed to be license to proceed with the work and not as authority to violate, cancel, elter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring o correction of errors in plans, construction or-violations of any codes, Every pamnitissued ohaUbecome invalid unless the work authorized by such permit is commenced within nix months of permit issuanoa, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be n*qVeobyd, in writing, from the Building Official for m period not to exceed ninety (BO) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned, WARNING TO OWNER: YOUR G&|LOR2 TO RECORD A NOTICE OF COK0K8E0C2K0E0T MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDE OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and swor 4 u�+q�r�/x- . - W�_o_is/are personally known to me or hasihave pFGdueed Who is/are personally known to me or haedhave pFedue as identification. as identification. Notary Public Notarypubiv Commission No. FF98537 Commission No. PF98537 IfivaaM.Holleran Eliu uM.IIoDerau p��b, "1�"^y; '•�qU'� wee V k .,Xr� `�Esk'=--� �' !' `\•` jW�•"�A(' v`ll i,2j�,} _� j,.�1 1����-=' - �.{x" �' Y `�h'r47.iU iF. t' �q � -� s',7;"•" ,: �,,;,-r'"'�, � - '1'S.`�_" :lea" .a � �.,'%" '��,-� ,���- •i95�. °�0'1�r�,"c ;,,•�`�`�. - J. - 7.�' .:�S.q: a �9. c3-� 1 ry ,1t J . f- •fit i't�` "1.= .,,.r-r$ �` `,I•/' , r,'`i' r'%� , FFz:99`20 a '\ F - '4,t3, ./ `sr'•itf di �9R9t,: . � 'g''' -'T''°., j ``%: .• LOT $.$D r;$"'"mac:•= �"R ,a^5� `` '^ `n!t'a�.! - t �' y `::.e"�.s'�_��;.���.: .,��,P-� ? �OT',g.q'E �v�``wy^-' ' n..y OY.a a;;�p%n� �; o��t' ��t f..tig ~.�,.rY, 1 OD'.`'�' r 'iF r'�D-g;.� t 6 �""=�Eg-9•-.:�'`.. FTYRE,8. PTfYPE98. D 0T 9. SFr 10 g QLJ - V Ujg Q TT/ o t °`� \p°'g t � r. •�'.„ �C3'jr '�e,'�\q���, •31"4 �,,` •',• > g !+ ... ��f n n cj�t `�e!�1' a. t x• 5 1p h�q�' 6 ai { 1V1.2 a �l { •�t�' �t W• it- 'x1'PE 0 ��, �-.i,'(e g ,fie• J. °f"3 ��� V/ O 1, r' _ 4{{'}}b'.-,.� "•,`' 'i.�`��� /� �, , a - ~gs,Yrs. ;��srz:.;,,.,,.• •{g5�4r?'' .yg,..^ �`�`�:�, f Wn� y�y2 � �' �'�'� ' '� � k'�qa• a.gg ,� `Ff�a �^\ ��.; �:'.,;,rf• '7� %'=";':her, r D3.9D: 'f.. : .' ��.�•"•'-'- f t�+-+.m.;; ,^'=: :e�',.4��*<,'= r.O pUi4tP t�N,PAD� 'n � ,�t't `•�-ry!�, p ,'' �' •� ,�,,,„ �, `3�l 'k,TYFE.-g,, d�?' _ `y;:�'`� � o r—.'-�=�; ..dab" 'f0 _ -t ,iR. '.td�"'-`�! f/�>ya `F� ;�•^�,' .$ a°'�,•i�' ,fig r ,y:' .-`:•' -'`�` —'a„•..,� - � "'!"40 � "��i'' -�9 n - '•f,F•: ;ts g'ej"`^:t•-4.�>L� g •a-a�' O �ej'i• o t+' �q� F 1062D''. ,�,��+L f _.. ._ P, E T'3 �i� t.: :fit. =;r:., ---�p ti EXT51tN BLS` a c 6 0� 3.` PAD �O �� ;r;, f . g n g f p G;.STM, f Eir 7 6 1 1 1. �:_S (('��,, 4 i. 7� � 6, IMF+ 6, z—to fi!✓r tc< <ol 1YPQ'".g, V` d _s;•.•:"' yg ,°` h' s ArIDN' � FF,10�. t?t g6. �a',�y. � ACC�S v d fu `1 $� osp ' `✓ "{r',� ;. ��' L0T.58 Ff:g8.8D o �g ' a. DRIVE Ff. Q t�'A t9`'q POT 8>7ey h c f�g � typL;. . al -98.1 9 ' 4 J. ��: i -;� -LOT'2. ,f` '^'%''>♦" /; ,- ^"Y .e rr'w,} .Tk'P,�B - P 7 t? m "•' --•----' S `` PAD=• >? 3`e.-''7• x: `'�,: ..+:a<, AD"9 TYPE .•r..-I I ,1'• �- . u \� •:. t0.. V� �'r,�`���1��� ,' �� � ..� ��•' �,:n'.-�'• ,e'` i,• L gD� 1 91.`.' `�.`_.- „i��::� t,h- RQ, � ,� `•:�q,S�„`.-- � r' 07.D ,+01• �? .* ,:.;;+ �,r ,.r 9: 10 ''�` , � ''' � �•yg`�� r 6 ,l - _ AFL 109.70 ,i� �==k, 1''•' .-n! ,' >� Eqj � `'' ' ti'``•,,, '?�:� - '— �' PAD�10 -` / p' .f1" :,, s ;; g�#3, O,qo• p /- �. ISFFT 0 -. / v` t A— ��''. �, x`�.:' :4., t• 1 , +'A, rag /� °4 ;$ r rs `�I/p6 [) Y" 7�•� - q:5' g•6'`''•Sry' `' '„!, ?- f2K' i ,'`�'q�i;'./ r.' •�'' ' , ..ca ,,�, '- ''^�� .�•. 4s•t ~ R,� 4' /_ t. r' ry�'rJ�. r � i � r`•l _ �A' .'�"•,`` -'t� tti .i..+'s ' ,�1. ; ,, i e m \��.s -- `_-`'``�"'•T---• ��f�"�. ..'+,•; � �r�'. �:$t` � FF 107,70' 't��Fy g ,l,' t�`L�-9�' r 6r' {3 �? "� '�4. ^.. --'-1...��-- -���::,aM `;, .. '� +?.'� i `f, �/. •i PADc107:0 sir. - �/' , t i Tg5-�9ti �. o �`� �4`�'fi` --,,..'- -- �'' „it}''':i'*•^ .F"•.i�, 'j�F�A,Q i .� ' ,J` :`; :t7 •r`59� '�'j,1 �'�•...•�9-,-. /.,; i , � �1 ��•� gs�;3 ,_ _ ti9,. - � ; � �� gS i. ,+, !1 S g(s•., .�{yx `;c9. yS�`t w floes r• `�; ,FF,t105.00; + i y /i �''.') ; I ; c}k. ,,r ,-_-=- .^;` x+ „`�'�-� 1.` 'a� t{ , : PADxU08.3'.�+�a= ,.. �• � .:R1, ;/j I:. � � r.�.g�'; �, �'�'2� Y•� 'o '�t�•�� dg.�^.'.:,�, � ��.,�. TYPE'H', � ,;p�'; ,� II•� ;"r 6`a �hk >$4,$a ��'� ts. �....�,�.. r0��•. �'�•. T' , 7 , - ��. i" $•� / I ����'' ,fig_` i,�p9 �' �'``-; �'t� ,,.1' - t ,�*�. ��.��..� gs_ `,..• \ �' , i /'qt2"�`° 9'. �. � ' Yt :; a to `', t ; X46 S`1��,3'-t' `t'i.-- '� `1 51'6 1 -r ri i.�i "I�' � t•�1 )� �tf`g�k�C ,r,. �, [//y � X'g�` V�t'j< :`i,•�i `7�l\ •; t' ,..� 'ry.: • '�� '/;`;' ri. �. ± / ,9�g� �qr'`F! e, %-& ; j 7• .y.i •�1.,�' f: � ,'t ,' / �. i •fir `"L,5J. .l ti.-• , ('r g�`•,. R�i.. ,. �.ft� ♦ i-i./►� `";:0 0�tryq:t� l f�51 ��9h` icat.rz' g1�5 �,., t c M1'�4g�tg? #9 F�"`► _►Y� v ; +`, SKETCH ONLY SEC. 04 , TWP. ?6 S, RNG, 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 4, BLOCK 9 SILVLRADO RANCH SUBDIVISION PHASE 5A WEST BOUNDARY OF SUBJECT PLAT BEING IN 3642'29" E PASCO COUNTY, FLORIDA. DO NOT SCALE THIS PRINT. DIMENSIONS AND NOTES TAKE PREFERENCE. PRELIMINARY DRAWING: ALL DATA SHOWN HEREON BASED ON THE THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY ENGINEERING PLANS OF HAMILTON ENGINEERING ALL DIMENSIONS BEFORE ANY CONSTRUCTION. & SURVEYING, INC., PROVIDED BY LENNARII HOMES. LEGEND: = 10' UTILITY EASEMENT -.Alv—= PROPOSED DRAINAGE FLOW LLJ (00.00) = PROPOSED GRADE ON LOT AREA CALCULATIONS E-00.00 = EXISTING GRADE to LOT ' = Z5_4_2A8__SQ. FT. T LIVING AREA 257 --SCL FT. NOTES: ENTRY 156—SQ. FT. LOT GRADING TYPE = B GARAGE 674 --SQ. FT. PROPOSED PAD ELEVATION = 103.2' COVERED LANAI FT. FRONT SET BACK = 20' PATIO SO. FT. SIDE SET BACK = 7.5' CONC. DRIVE = 705 --SQ. FT. REAR SETBACK = 15' A/C & CONC PAD = 12 SO. FT. PRIVATE SIDEWALK = 30--SQ. FT. IMPERVIOUS 55 ---% 4153--SQ. FT, PRM(P) SOD 3396 —SQ. FT. OFF LOT AREA CALCULATIONS RIGHT OF WAY =--11-67,32 SO. FT. LOT 17 0 DRIVE APRON =__.q_4_R _._ _SQ, FT. CD .30, PUBLIC SIDEWALK =_ 325 0. FT. BLOCK 1 6 SOD = L9_-3SQ. FT. SILVERADO RANCH PHASES 2, 3&4 (PLAT BOOK 73, PAGE 59) TOTALS (b LOT 5 AREA = E7_0GI._9_O SO. FT. BLOCK 9 DRIVEWAY =--10-5-4 __SO. FT. ri SS, SIDEWALK =--15-5SQ. FT. SOD = 3883 SQ. FT. ro TT 0>1 A) ;rt %K Qj PLAT BOUNDARY 70 4j- CO .7,>. Aj AN.. -.4 01? LOT 3 BLOCK 9 t� AZ {502.26'} V _N 4: PROPOSED: I CURVE I RADIUS I ARC I CHORD I BEARING I DELTA::: LOWEST FLOOR ELEVATIONS: 1 C13 1 220,00- 1 3.64- 1 3.64' 1 S 37-1053- W I Ofi�W52 � LIVING AREA: 103.90' DESCRIPTION: GARAGE AREA: 103,36' ELEVATIONS REFERENCED TO LOT 4, BLOCK 9, MAP OR PLAT ENTITLED "SILVERADO RANCH NORTH AMERICAN VERTICAL SUBDIVISION PHASE 5A", AS RECORDED IN PLAT BOOK 078, PAGES 033 DATUM OF 1988. MEAN SEA THROUGH 037, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101C 0452 F EFFECTIVE DATE: 9/26/14 Square Feet: 7542.58 ± I LENNAR HOMES — (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC- CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F7 WOOD FENCE Drawn El JOHN R.BEACH&ASSOCIATES,INC. Sms y. SURVEYORS AND MAPPERS Checked By. t 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: NOT VALID WITHOUT ORIGINAL SIGNATURE jpate: PLOT PLAN 4/25/19 ACS AND THE RAISED SEAL OF A FLORIDA SIpdA1bkE DATE LICENSED SURVEYOR AND MAPPER lornWKI R. gfthrW Revisions:' REVISED PER STREET NAME 5/30/19 JBS 6 RE . LAND SURVEYOR No. 2954 LB#4493 FLORIDAA fJEFFF M_. UMTLEY FESSIONAL SURVEYOR & MAPPER No.7123 CITY OF / / BUILDING " NOTIC, E ZEPHYRHILLSDEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT# 21e THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS,ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-002Q FOR r $ �.'TION or other material,until the proper inspector has had ample time to approve 'the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DAri PERMIT �(6 (0 � �, � �, �> � [ter Z t W."i THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. itAOL It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR� �5� PASCO COUNTY A r BUILDING CONSTRUCTION SERVICES P, IS C � 8731 Citizens Drive Date:7/12/2019 COUNTY PLORIDA Suite 230 Orrw SPACES.ViBMW PLAM. New Port Richey,FL 34654 727-847-8126 NOT A PERMIT Receipt#: 1874210 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1478853 $33.66 $33.66 1874210 7/12/19 Waste Single Family TOTALS: $33.66 $33.66 Receipt# Paid By Check CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1874210 Check 01257333 EBESS BCCCP58W 07/12/2019 $33.66 Total Payments: $33.66 Pavor Address Phone LENNAR HOMES LLC TAMPA DIVISION 4600 WEST CYPRESS ST STE 200 TAMPA,FL 33607 Comments: 6365 COBBLE BLISS ST While you will be paying your bill with Pasco County Building Construction Services,the full amount of the credit card or a-check tees,NOT shown above,is collected by First Billing payment services. myreports/reports//PASCOPROD/PASCO/ReceiptAA V7.rpt 7/12/2019 Page 1 of 1 Building and Construction Services (BCS) PAS C COUNTY FLORIDA 011EN SPACES. I-'rc MINFi`PLACES. BlowerDoorTest ��®@ ®6�S`d1 Property Address: Uriit ti: ' r-L I Permit N: TesY Corpp y Name: Test Date: T ter N me: �� -' . Tester Ce �� Conta Phone: E 402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).As required by the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior to Certificate of Occupancy issuance. Testing shall be performed at any time after creation of all scheduled penetrations of the building thermal envelope. During testing:(check to verify condition met) ❑ Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weather-stripping or other ❑Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration ❑Interior doors,if installed at the time of the test,shall be open ❑Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed ❑Heating and cooling systems,if installed at the time of the test,shall be turned off ❑Supply and return registers,if installed at the time of the test,shall be fully open Vb Building volume(fl) _ 1 j 7 , J a. Q50 Airflow at 50 Pascal(CFK I _ ACHso Air changes per hour at 50 Pascal Qso x 60_Vb = Lj, ACHso (10 ACH minimum) Pass tl Fail ❑ ❑Outside Air mechanically introduced to space(less than 3.0 ACH) I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. i afore of Tester `Date J b /�— Jet Stream"" Ultra Blowing Wool Insulation kNAN[ e Attic and Cavity Wall Card ih ,dive h mve,exerr T 0C, CV Batts and Blankets tquipment Required �- When installed in accordance with the manufacturer's It Its recommended that a pneumatic blowing machine and a corrugated hose with a minimum'/V internal corrugation,a minimum length recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 35'in diameter.Acceptable material feed rate is 5-35 Ibs/ndnute.Recommended feed provide the fug R-value. rate is 15-25lbslminute. R-Value* Minimum Thickness' Thermal Performance(Sidewall and Attic Application) To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label (R-Value)of: not he less than: val result in lower installed R-values.Feld blending of this product with otherloose M insulations is not recommended by the manufacturer. R-49 13.75' Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 Ills. R-38HD 10.25' R-38 12.00' R-Value* Bags per 1000 SF, Maximum Net Minimum To obtain an The number of bags Coverage per Bag Weight per SF R-30HD 8.25' insulation per 1,000 square feet Contents of this The weight per square R-30 10.00, Cavity resistance of net area should not bag should not feel of installed insulation R-26 9.00, Framing Depth of: Density be less than: cover more than: should not be less than: R-22 6.50" Tx 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 tbs. R-21HD 5.50, 2'x 6° 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 tbs. R-19 6.25- 2'x 8" 7 25' R-31 1.8 lWcu.ft. 34.0 bags 29.4 sq.ft 1.088 tbs. R-15HO 3.50° R-13 3.50" 2"x 10" 9,25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft 1.388 tbs. R-11 3.50' R means resistance to heal fow.The higher the R-value,the greater the Insulating power.To get Ore marked it-value,a is essential that this Insulation be installed property. R-8 2.50' ^R-16ina5.5"cavity.Conforms toASTMC665 and Federal Open Attic Application bag Net Weight-Nominal 321bs.,Minimum 31 lbs. Specifica5m HH-1521F. I Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for framing members,the number of bags per The number otbags/ coolants of this The wetght/5F Thickness Contents of this i.000 sq.it of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of Installed Installed insulation bag should Ba SIMSF Ba s/MSF To obtain an Insulation should not be less cover Insulation should not should not he less not cover more 9 9 resistance(R-Value)of: Than: more than: be less than than: than: Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952tbs. 19.750" 19.750" R-Value Dimensions Framing Framing 9.2 29.4 R-49 23.5 42.5 SF .753 tbs. 16.375" 16.375° 2x4 2 R-60 2x6 28.929,1 R-44 20.9 47.8 SF .670Ibs. 14.876' 14.875" 2x8 28.6 28.9 R-38 17.8 } 56.2 SF .569 tbs. 13.000' 13.000, 2x4 23.0 23.2 R-30 13.6 ; 73.3 SF .437 tbs. 10.375' 10.375" R49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 tbs. 9.125' 9.125' 2x8 22.4 227 R-22 I 9.8 102.2 SF .313 tbs. 7.750' 7.750' 2x4 20.4 20.6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 tbs. 6.750" 6.750' 2x8 19.8 20.1 R-13 5.7 175.3 SF .183 tbs. 4,750° 1 4.750' 2x4 17.3 17.4 R-11 4.7 210.8 SF .152 tbs. 4.000" 4.000' R-38 2x6 17.0 17.2 eaotmweghl-Nm�nal32bs-kt 112- 2x8 16.7 17.0 cmreseralhstneatimdets,Pew-segatxAAtzdobp i�gmuhmehwrogw,,ithirgatsoyai,g,20 µd&pms .w dlwm Tble=y.cmmgEfedt . 2x4 13.2 13.3 Th'"ea'at cord""°"Lhe r- z jN�rC7-K Typ--L lid mnceW Faded spmfira7m V44-100.Type LCass e.R-v&n am deed In aaadaflm%MG6arend CSIS. 'w memo;resstwo to beat raeTbe?kr+.,s• --x Feafr5a matzal pair.To get ft aadmd Ri-,M-ac 5LSz;vas'vdJ.�anba instafn:lpmpedy:it yvu doilyaese7,gel'nsWo- R-30 2x5 12.9 13.1 �"smarmormrmaasmr. a Ysre�-rs �a�• 'Eased on TNrd Party 2-yesrs°65tis;s"�•F:a -'>==aro a aNeeperoi xal!ba t oar....:xL�.ifs arost�se5g b thennaTjinsignifranl lhaelre.Ur iala!ed ud rettlW } 2x8 12.6 12.9 Hdme ws am enecNely ltm�re } 2x4 11.3 11.4 vabWatica is a mglsrered aed"rat9lsE R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has begirt irs h ccrifumance vrith the included r-commendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 i 2x6 9.1 9.3 Attic Area R `✓ at 0- 7h Inches 2x8 8.8 9.1 Sloped Ceilings R- at Inches i 2x4 7.9 8.1 Walls R- at Inches R-19 i 2x6 7.7 7.9 Floors(over an unitseted corn*r:�) R- at Inches } 2x8 7.4 7.7 2x4 5.3 5.4 Crawl Space Perim R- at Inches R-13 2x6 5.0 52 Date Installed 1 i 2x8 4.8 5.0 �~ Blown i sulation h4' t-taei. s c a with the above recomgl%nd 'ons to provide an R-value of e 2x4 4.3 4.4 R_ u .. : ` Iftsula In to cov 9 square feet of area R-11 2x6 4.1 4.3 �'� at a minimum thicimess 2x8 3.8 4.1 ULE-i--, Insulationconc-M,Imo] t:"mdwobnon b,a&n n.mrvmo°chk ed Company 'F Date U1 Ecr'vwm.GRfENGUAtD Grid®d b UL b ba rmcddehyde be" UL&A-aw GREENGUARD Home Builder(ss�ri Certanvlion P,e9r"my -pmdue. ce"at"dmIAE 6. b +a Gac'e:GLIl1ARG tlandmd,hr dx" Company Date °iiwiau'No mdm.av durag p,vdutl vwge. •. .. •. ,'.' � ' Fa.vre mhmWim,tint.[-/ea. . The wverege irtformaBGaca;BastvffirJStdeaeait card applies to the entire United States(including Mfnnesotd). s> Knauf Insulation`'lrtr C �i rf Drive,Shelbyville,IN 46176 Tel:(800)B25-4434 ext.8300 FAX:(317)398.3675~ lti+ievia3kea�unstilation ^v_: .. .jriJx'r - z� r' ©2015 Knautiris�-ti-A,Inc.